Narrow Parabolic / 1 or 2-Lamp T5, T5HO, T8
Project Information
Project Name
Type
Catalog No.
Date
Construction
Features
• 6" aperture suits a variety of applications
• Continuous louver provides a sleek, unbroken appearance in
row applications
• Available with flush or regressed trim
• One or two-lamp cross sections
• Shielding options include parabolic louver, cross baffle, or
lens
• Damp label standard
• NEC/CEC-compliant ballast disconnect standard
Fixture housing is constructed of die formed
code gauge steel. Louvers tip into place and are
permanently aligned by matching grooves at fixture
sides.
Finish
Painted parts are finished with a high temperature
baked white enamel. Louvers are low iridescent
semi-specular (diffuse) natural anodized (LD)
aluminum as standard.
Ceiling Compatibility
Installation
An adapter plate is furnished with each luminaire
for fast wiring connections without the necessity of
opening the fixture or wireway. A mylar dust cover
which eliminates construction dust contamination
is standard. Single circuit Tandem wiring is standard
for continuous row fixtures. All shielding and
hangers ship separately.
Ballasts
Energy efficient, thermally protected, automatic
resetting, Class P, high power factor, sound rated A,
magnetic or electronic ballasts. CEE NEMA Premium
compliant.
Ordering Information
NP
–
No. of Lamps
Model
1 One
2 Two
Size
62
63
64
66
68
6" × 2'
6" × 3'
6" × 4'
6" × 6'
6" × 8'
*Note: Shielding ships separately.
Page 1/2 Rev. 07/25/12
CORNERS
Continuous shielding illuminated butt joint corners
are available for use in 90° patterns. For more
information please call your representative or
contact the factory.
–
–
–
–
Ceiling Type
Shielding*
Voltage
Options
G Grid (For 1" inverted T-bar)
F Overlap Flange Trim
(For hard ceilings)
GT Integral Cross-tee (Grid
ends lay into standard
T-bar, sides act as integral
cross-tee to support tile)
LD Low Iridescent
Semi-Specular
Parabolic Louver
LS Specular Parabolic
Louver
WCB White Cross Baffle
A12 Acrylic Pattern 12 Lens
A19 Acrylic Pattern 19 Lens
OA Opal Acrylic Lens
U 120V-277V
347 347V
GLR Fast Blow Fuse
GMF Slow Blow Fuse
EL Emergency
Battery Pack
NYC NYC Compliant
NYCU NYC Compliant,
Union Label
Lamp Type
17
25
28
32
54
NP is designed to fit into lay-in (Type G) grid ceilings
or concealed suspension (Type F) ceilings requiring
an overlapping flange. It is also available in an endsupport (Type GT) model which carries the ceiling
tile on fixture side tees (see NP-Narrow Parabolic
Technical Installation Data). Fixture in exposed
grid ceilings (Type G) will have row interrupting
cross-tees on 4' centers. For uninterrupted shielding
without cross tee use end-of-row and intermediate
fixtures.
Example NP64-232G-FS-LD-EU-SGL
–
NP Narrow
Parabolic
Electrical
Standard class “P”, thermally protected,
autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.
2', T8: 17 Watt
3', T8: 25 Watt
4', T5: 28 Watt
4', T8: 32, 30, 28 or 25 Watt
4', T5HO: 54 or 51 Watt
Trim type
FS Flush Trim Steel
(Grid only)
FA Flush Trim
(N/A Grid Trim)
Ballast
Row configuration
Electronic T8, Instant Start
3-Lamp Electronic T8, Instant Start
4-Lamp Electronic T8, Instant Start
Electronic T5 or T8, Programmed Start
3-Lamp Electronic T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A 347V)
or T8, Programmed Start
For a specific ballast vendor show as option.
SGL Single (Cross tee installations only)
EORRH End-of-Row Right Hand*
(No cross-tees between housing)
EORLH End-of-Row Left Hand*
(No cross-tees between housing)
INT Intermediate*
(No cross-tees between housing)
*Integral in-row wiring. Single circuit
standard.
E
3E
4E
EP
3EP
Parabolics / NP
© 2012 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
np
Narrow Parabolic / 1 or 2-Lamp T5, T5HO, T8
Photometric Data
Test 12640 Test Date 1/8/03
Luminaire Data
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Shielding Angle
Luminous Opening
in Feet
Zonal Lumen Summary
Zone
NP64-232-FALD-E
NP Parabolic
6" × 48" 2-Lamp with 1 × 12 Cell
Semi-Specular Louver
B232I120RH-A
0.88
F32T8
2900
56
0° = 30 90° = 35
Length: 3.87
Width: 0.35
Height: 0.00
Lumens % Lamp % Fixt.
0-30
0-40
0-60
0-90
0-180
1208
1962
3090
3197
3197
20.8
33.8
53.3
55.1
55.1
Indoor Candela Plot
RCR
70
62
57
53
49
46
42
40
37
35
32
80
50 30
60 58
54 51
48 45
44 40
40 35
36 32
33 29
30 26
28 24
26 22
10
56
48
42
37
32
29
26
23
21
19
70
60
56
52
48
45
41
39
36
34
32
70
50 30
58 57
53 50
48 44
43 39
39 35
36 31
33 28
30 26
28 24
26 22
10
55
48
42
36
32
29
26
23
21
19
50
56
51
46
42
38
35
32
29
27
25
50
30
55
49
43
38
34
31
28
26
23
21
Total Luminaire Efficiency
55.1%
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004
Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
50
Yes - VDT Normal
Use
$4.80 based on
3000 hrs. and
$0.08 per KWH
AVG. LUMINANCE (Candela/Sq. M.)
0.0
Coefficients of Utilization (%)
RC
RW
1
2
3
4
5
6
7
8
9
10
37.8
61.4
96.6
100.0
100.0
Energy Data
Average Luminance Angle
Luminaire
10
54
47
41
36
32
28
25
23
21
19
0
0
49
44
38
34
30
27
24
22
20
18
0 12325
30 11736
40 11141
45 10553
50 9520
55 6678
60 1860
65 790
70
511
75 368
80 275
85 182
22.5
45.0
67.5
90.0
12325
11957
11131
10429
9186
6983
3052
809
488
338
275
182
12325
11709
11173
10699
9136
6692
3671
1523
534
338
229
182
12325
11764
12013
10407
8234
5764
4355
1805
674
399
275
182
12325
11856
12117
10351
7715
6027
5038
1523
674
399
275
182
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Dimensional Data
Type G Lay-in exposed grid. Fits standard 1" wide, 1½" tall tee.
Flush Trim
Type GT Integral cross-tee (grid ends lay into standard T-bar,
sides act as integral cross-tee to support tile). Fits standard 1"
wide, 1½" tall tee. Cut ceiling tile into two 87⁄8" strips.
Regressed Trim
53⁄4"
End View
6"
73⁄4"
6"
6" C-C Tees
7" C-C Tees
6" R.O.
Type F For hard ceiling applications. Yoke hangers are shipped separately. Carrier channel by others.
Flush Flange
Regressed Flange
Side View
71⁄4" I.D. Carr. Chan.
71⁄4" I.D. Carr. Chan.
6"
51⁄2" Max.
3" Min.
73⁄4"
71⁄8" Max.
43⁄4" Min.
6" R.O.
63⁄8" O.A. Trim
Nominal
6" R.O.
67⁄8" O.A. Trim
NOTE:
All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 07/25/12
Parabolics / NP
© 2012 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com