LED Machine Lighting LF1E LF1E Series Lumifa Key features: The LF1E illumination lights are designed to be used in freezers or refrigerated display cases where the ambient temperature is as low as -40ºC. These energy saving units, with a long service life, compact size and low heat generation make them perfect for illuminating areas with very low temperatures. • Three types of light distribution: no-lens, condensing lens and dual lens • Life: 70% of initial luminance at 40,000 Hrs • Available in 4 lengths • Plastic lenses suitable for food industry • IP54 protection against dust and water • CE marked, UL Listed (damp locations) Part Numbers LF1E-B3S-2*† (550mm) LF1E-C3S-2*† (808mm) LF1E-D3S-2*† (1066mm) LF1E-E3S-2*† (1450mm) warm white shown cool white shown cool white shown cool white shown * N = Cool white, L: Warm white. † Blank = No lens, A = Condensing Lens, B = Dual Lens. Part Number Structure (use for interpreting part numbers only) LF1E– B 3 S–2 N A Length (mm) B: 550 (21.65") C: 808 (31.81") D: 1,066 (41.97") E: 1,450 (57.09") LED Color N: Cool white (5,000K equivalent) L: Warm white (3,000K equivalent) Light Distribution (lens type) Blank: No Lens A: Condensing Lens B: Dual Lens Note: Mounting brackets included 800-262-IDEC (4332) • USA & Canada 17 LED Machine Lighting LF1E Specifications Lumifa Model (length) LF1E-B (550mm) Rated Voltage LF1E-C (808mm) LF1E-D (1066mm) LF1E-E (1450mm) 24V DC (Voltage range: 21.6 - 26.4VDC) Input Current (at rated voltage) 24V DC 350mA (404mA max) 525mA (606mA max) 700mA (807mA max) 950mA (1004mA max) Power Consumption (typ. at rated input) 24V DC 8.4W (9.7W max) 12.6W (14.6W max) 16.8W (19.4W max) 22.8W (26.3W max) Insulation Resistance 100 MΩ minimum (500V DC megger) between input and housing Dielectric Strength 500V AC, 1 minute Vibration Resistance (damage limits) Frequency 5 to 55Hz, amplitude 0.17mm Shock Resistance (damage limits) 300m/s2 Operating Temperature –40 to +40°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Storage Temperature –40 to +70°C (no freezing) Operating Environment No corrosive gases 40,000 hours (The illumination duration in which the illuminance maintains a minimum of 70% of the initial value at 25ºC.) Life Weight (approx.) 1 275g 390g Degree of protection Material LED Optical Specifcations Illumination Color Cool White Warm White Color Temperature 5000K 3000K No Lens 1 Condensing Lens 2 Dual Lens Unit Length Reference Illumination 550mm 950lx 750lx 808mm 1,100lx 900lx 1066mm 1,200lx 950lx 1450mm 1,250lx 1,000lx 550mm 1,950lx 1,500lx 808mm 2,000lx 1,550lx 1066mm 2,000lx 1,550lx 1450mm 2,000lx 1,550lx See Illumination Distrbution Chart 1. LED life depends on the operating environment. 2. Measured at 0.3m directly below unit. 18 690g End cover, conduit: polyamide, Cover: polycarbonate, Cable: PVC, Mounting bracket: stainless steel 1. Dual lens type. Lens Type 515g IP54 www.IDEC.com LED Machine Lighting LF1E Illuminance Distribution Charts No-lens Condensing Lens 90° 45° Dual Lens 0 20 40 60 80 100 (%) 90° 90° 45° 45° X: long side Y: short side Lumifa 0 20 40 60 80 100 (%) 90° 45° 0° 0° Y (short side) image Y (short side) image Y (short side) image Illuminance Charts No-lens (LF1E-E3S-2N) Condensing Lens (LF1E-E3S-2NA) -500 -300 600 -100 0 1400 100 1000 1200 -400 -300 400 -200 800 Y (mm) -100 0 200 300 400 500 -1000 -800 400 500 -1000 -800 -400 -200 0 200 X (mm) 400 600 800 1000 -200 1600 2000 300 No-lens (LF1E-B3S-2N) 400 600 800 -200 -400 -200 0 200 X (mm) 400 600 800 -100 0 500 -750-650-550-450-350-250 -150 -50 50 150 250 350 450 550 650 750 X (mm) Dual Lens (LF1E-B3S-2NB) -400 -100 0 300 400 500 -1000 -800 400 500 -1000 -800 0 200 X (mm) 400 600 800 1000 -200 2000 100 200 -200 -300 800 1200 1600 300 -400 100 400 400 -200 200 -600 0 -500 -300 1000 100 1000 1500 1250 750 300 1000 -400 200 Y (mm) -300 500 200 -600 -500 -400 -100 Condensing Lens (LF1E-B3S-2NA) -500 250 -300 1200 100 200 -600 800 Y (mm) Y (mm) -200 -400 200 400 -500 Y (mm) -400 Y (mm) Dual Lens (LF1E-E3S-2NB) -500 -100 0 100 200 -600 -400 -200 0 200 X (mm) 400 600 800 1000 300 250 500 1000 750 1500 1250 1500 1250 1000 750 500 250 400 500 -750-650-550-450-350-250-150 -50 50 150 250 350 450 550 650 750 X (mm) Dimensions (mm) Conduit Cable Brown: L (+) End Cover Cover Cable length: 300 Partially-stripped (×2) 18 AWG 18.8 Blue: N (–) ø5.9 36 L 20 max. Part No. LF1E-B3 L mm A inch 550 21.65 LF1E-C3 808 31.81 LF1E-D3 1,066 41.97 LF1E-E3 1,450 (35) B 57.09 mm B inch 585 40 max. Dimension Table 23.03 mm 30 inch 1.18 mounting 843Recommended 33.19 29 1.14 centers (D) 1,101C 43.35 1,485 A 48.46 L C M4 screw Mounting Bracket (supplied) mm inch mm (supplied) D inch Mounting Bracket Quantity Included 490 19.29 490 19.29 2 750 29.53 375 14.76 3 30.5 1.20 1,005 39.57 335 13.19 4 32 1.26 1,386 54.57 462 18.19 4 Minimum Radius 24 mm Anti-rotation Hole (Use one) ø2 6 6 .1 M4 × P0.7 tapped hole or ø4.2 hole 800-262-IDEC (4332) • USA & Canada 19 LED Machine Lighting Accessories Accessories Lumifa Item Mounting Bracket Part No. LF9Z-1MB1 LF9Z-1MA1 Applicable Unit LF1B-NA, -B, -C (-D not applicable) LF1A-A, -B, -D LF9Z-B12 LF9Z-B11 LF9Z-1MDE1 LF1D (Slim) Material LF9Z-1MDF1 LF1D (Wide) Cable Gland Cable LF9Z-1SE1 LF9Z-A11 LF9Z-C05 LF1E LF1D LF1D Brass PVC M8, applicable wire size (10-12 AWG) Length: 5m Stainless Steel 1 pair Left and Right Notes 1 piece Dimensions (mm) LF9Z-1MB1/1MA1 A LF9Z-1MB1 LF9Z-1MA1 mm inch mm inch mm inch 1.08 35.2 1.39 27 1.06 50.5 1.99 33 1.30 80 55 2.17 .6 10 2 3.15 8 13.6 20 74.6 60 40 R2 2-5.2 .6 2.0 10 2 8 13.6 20 LF9Z-1SE1 .2 Thickness = 0.4 14 ø4 1.7 1.49 R2 2.0 4- 11.0 20.0 37.9 4- LF9Z-B12 25.0 31.4 .6 inch 49.4 40.0 LF9Z-B11 R2 mm 27.5 2-5.2 C 11.0 20.0 A (When fixed at 90°) 4- D B LED Illumination Unit C 74.6 60 .6 B 40 D R2 49.4 40.0 4- 25.0 31.4 Part No. 12 35 1.2 max. 36 LF9Z-1MDE1 ø8 10 ° 90 0 90 R6 R45 50 77 (87.5) 27.5 36 28 62 66 53 (73) ° 36 M4 × P0.7 LF9Z-1MDF1 13 75 800-262-IDEC (4332) • USA & Canada 9 25 Safety Precautions LED Machine Lighting Lumifa Safety Precautions • To avoid electric shock, fire, or malfunction do not disassemble, repair, or modify the unit. • Turn power off before wiring. To prevent electric shock or damage, ensure wiring is correct. • Do not stare directly into the LF1B-N unit while it is lit, and do not project the light towards other people, as their eyes may be injured. • The LF1B-N is a general-purpose industrial electric device. Do not use with electronic equipment which may cause harm or injury to anyone in case a malfunction or failure occurs. • Please adhere to the operating temperature specification. A rise in internal temperature may damage the product. Instructions • LED modules may vary slightly in color and brightness. • Before designing equipment and powering up units, confirm the specifications described in the instruction sheet. • Apply voltage within the rated values, otherwise the LED elements may be damaged. • The unit is vulnerable to static electricity. Take sufficient measures for protection against static electricity and voltage surges. • Make sure that the unit is not dropped during transportation, installation, and operation, otherwise damage may result. • Do not pull or push the cable, otherwise damage may result. Allow sufficient slack to the cable while wiring. • Do not apply excessive force. Do not leave a damaged unit unattended or use a damaged unit. • Ensure the correct operating temperature, as rise in internal temperature may result in damage to the unit. • Do not use or store in a location subject to vibration and shock. • Do not use in the following locations: - Exposure to direct sunlight, near heaters, high temperatures - Subject to chemicals, and corrosive gases - Cold storage warehouses (make sure that no freezing occurs) - Places with high humidity such as basements and greenhouses • Do not loosen screws, otherwise, the protection characteristics will be impaired. • To clean the cover use a soft cloth with water or neutral detergent. Do not use solvents such as thinners, benzene, or alkaline, otherwise discoloration, deterioration, or decrease in strength may occur. • The edge of the cable sheath is not waterproof. Moisture may be drawn in to the unit if water splashes directly onto the cable sheath. 26 www.IDEC.com