Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 Fisherr FIELDVUEt DVC6200 Digital Valve Controller / Magnet Assembly Dimensions Configuration(1) Digital Valve Controller Mounting Figure Page With integrally mounted filter regulator 1 1, 2 Integral mounting to the Fisher GX control valve and actuator system DVC6200 DVC6200f DVC6200p Integral mounting to Fisher rotary actuators Sliding-stem linear applications Quarter-turn rotary applications DVC6205 DVC6205f DVC6205p Remote mount base unit ‐‐‐ 2 3 DVC6215 Feedback unit ‐‐‐ 3 4 1. DVC6200 digital valve controllers can also be mounted on other actuators that comply with IEC 60534-6-1, IEC 60534-6-2, VDI/VDE 3845 and NAMUR mounting standards. Magnet Assembly(1) Figure Page SStem #19 19 mm / 3/4 inch 4 4 SStem #25 25 mm / 1 inch 5 4 SStem #38 38 mm / 1-1/2 inch 6 5 SStem #50 50 mm / 2 inch 7 5 SStem #100 100 mm 4 inch 8 6 SStem #210 210 mm / 8-1/4 inch 9 6 RShaft #1 / LRC(2) Fisher 2052 Size 1 & 3, 1051/1052 Size 40-70, 1061 Size 30-100, Sliding Stem > 210 mm (8.25 inches) 10 7 RShaft #2 / LRC(2) 2052 Size 1, 1051/1052 Size 20-33 10 7 RShaft End 90 degree 11 8 1. Linear magnet assembly width dimensions are shown in figure 6. 2. Linear Roller Cam. Figure 1. FIELDVUE DVC6200, DVC6200f, and DVC6200p Digital Valve Controller with Integrally Mounted Filter Regulator 298.4 (11.75) 148.1 (5.83) 54.9 (2.16) 1/2-14 NPT CONDUIT CONN BOTH SIDES www.Fisher.com 1/4-18 NPT OUTPUT CONN A 61.1 (2.4) FISHER 67CFR 1/4-18 NPT SUPPLY CONN 59.4 (2.34) 3/8-18 NPT VENT CONN mm (INCH) 1/4-18 NPT OUTPUT CONN B 203.4 (8.00) Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 Figure 1. FIELDVUE DVC6200, DVC6200f, and DVC6200p Digital Valve Controller with Integrally Mounted Filter Regulator (continued) 57.7 (2.27) 184.4 (7.26) 102.9 (4.05) 145.7 (5.73) 12.9 (0.51) M6 X 1-6H 17.7 (0.70) M8 X 1.25-6H 1 57 (2.24) 35.4 (1.39) 35.3 (1.38) 34.6 (1.36) 35.4 (1.39) GE42896 1 2 35 32.3 (1.38) (1.27) 92.4 (3.64) BACK VIEW (REGULATOR NOT SHOWN) Housing insert for SSTEM #210 magnet assembly (figure 9) inserted here. mm (INCH) Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 Figure 2. FIELDVUE DVC6205, DVC6205f, and DVC6205p Remote Mount Base Unit Envelope Dimensions 56.6 (2.23) 1/4-18 NPT OUTPUT CONNECTION A 1/2-14 NPT CONDUIT CONNECTION BOTH SIDES 59.2 (2.33) 209.8 (8.26) 132 (5.20) 1/2-14 NPT CONDUIT CONNECTION BOTH SIDES 148.1 (5.83) 160.9 (6.33) 233 (9.17) 1/4-18 NPT OUTPUT CONNECTION B 79.6 (3.13) 123.9 (4.88) GE53722 mm (INCH) 3 Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 114.9 (4.53) Figure 3. FIELDVUE DVC6215 Feedback Unit Envelope Dimensions 1/4-18 NPT AIR PASSAGE 105.8 (4.16) 1/2-14 NPT CONDUIT CONNECTION BOTH SIDES 150.3 (5.92) mm (INCH) GE53725 Mounting hole locations for the DVC6215 feedback unit are the same as for the DVC6200, DVC6200f, and DVC6200p digital valve controller. Refer to the back view in figure 1. Aluminum Magnet Assemblies Figure 4. SStem #19 Magnet Assembly Figure 5. SStem #25 Magnet Assembly 2 61.05 (2.40) 61.05 (2.40) 16.05 (0.63) 31.2 (1.23) 18 (0.71) M4 X 0.7 - 6H THRU 15.9 (0.62) 31.2 (1.23) 18 (0.71) 5.5 (0.22) M4 X 0.7 - 6H THRU 32 (1.26) 8 - 19 mm (0.32 - 0.75 INCH) TRAVEL RANGE 4 2 mm (INCH) 5.5 (0.22) 32 (1.26) 20 - 25 mm (0.76 - 1.00 INCH) TRAVEL RANGE mm (INCH) Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 Figure 6. SStem #38 Magnet Assembly 73.75 (2.90) 6.3 2 (0.25) 15.9 (0.62) 31.2 (1.23) M4 X 0.7 - 6H THRU 18 (0.71) 5.5 (0.22) 32 (1.26) 6.3 2 (0.25) 26 - 38 mm (1.01 - 1.50 INCH) TRAVEL RANGE mm (INCH) Figure 7. SStem #50 Magnet Assembly 2 86.37 (3.40) 10 (0.39) 28.5 (1.12) 18.7 (0.74) 18 (0.71) M4 X 0.7 - 6H THRU 31.8 (1.25) 57.4 (2.26) 39 - 50 mm (1.51 - 2.00 INCH) TRAVEL RANGE mm (INCH) 5 Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 Figure 8. SStem #100 Magnet Assembly 2 137.18 (5.40) 10 (0.39) 28.5 (1.12) 18.7 (0.74) 18 (0.71) 31.8 (1.25) M4 X 0.7 - 6H THRU 108.2 (4.26) 51 - 100 mm (2.01 - 4.00 INCH) TRAVEL RANGE Figure 9. SStem #210 Magnet Assembly mm (INCH) 2 261.83 10.31 18.7 (0.74) 28.5 (1.12) 18 (0.71) M4 X 0.7 - 6H THRU 58 (2.28) 5.5 (0.22) 71.7 (2.82) 101 - 210 mm (4.01 - 8.25 INCH) TRAVEL RANGE 12.05 (0.47) 2.5 (0.10) HOUSING INSERT FOR SSTEM #210 MAGNET ASSEMBLY 1 1 6 Refer to back view of figure 1 for housing insert placement. mm (INCH) Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 Figure 10. RShaft Window Magnet Assemblies 114.6 (4.51) 95.3 (3.75) 194 (7.64) 174.6 (6.88) 57 (2.24) 33.3 (1.31) 5 X j 9 (0.35) THRU 5.3 (0.21) 29.5 (1.16) 74 (2.91) 109 (4.29) 4 X j 9.7 (0.38) THRU BRACKET BRACKET SPRING, BIAS SPRING, BIAS 54.9 (2.16) 39.7 (1.56) RSHAFT WINDOW #1 29.5 (1.16) 49.2 (1.94) 39.7 (1.56) RSHAFT WINDOW #2 mm (INCH) 7 Product Bulletin DVC6200 Digital Valve Controller 62.1:DVC6200(S1) May 2012 D103543X012 Figure 11. RShaft End Mount Magnet Assembly Related Documents n Bulletin 62.1:DVC6200—Fisher FIELDVUE DVC6200 4 X j 3.4 (0.13) THRU Digital Valve Controller (D103415X012) n Bulletin 62.1:DVC6200f—Fisher FIELDVUE j 22 (0.87) DVC6200f Digital Valve Controller (D103399X012) n Bulletin 62.1:DVC6200p—Fisher FIELDVUE DVC6200p Digital Valve Controller (D103564X012) 8.2 (0.32) All documents are available from your Emerson Process Management sales office. Also visit our website at www.FIELDVUE.com. j 28 (1.10) 36.8 (1.45) 7.2 (0.28) mm (INCH) Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.Fisher.com E 8 2011, 2012 Fisher Controls International LLC. All rights reserved.