Related Document - Border States Electric

advertisement
Tab3302.fm Page 52 Monday, October 23, 2000 10:07 PM
Back To Welcome
Contents
NEMA Contactors & Starters
3-Phase Magnetic Starters — Enclosed
33-52
January 2001
Vol. 2, Ref. No. [0068]
Freedom Line
Catalog Number Selection
Table 33-102. NEMA Freedom Line Enclosed Control Catalog Numbering System
ECN 22 2 1 A A F -
33
NEAL SV-
Design
NEMA
IEC
Advantage
Lighting
Solid-State
Vacuum
Page
33-40
34-69
33-100
37-13
39-20
Modification Codes
(See Pages 33-41 – 33-48)
Cover Control
(Starters Only)
(See Pages 33-50 – 33-51)
a
01 02 05 06 07 08 16 17 18 22 23 24 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 62 63 64 65 68 69 70 1
2
Number of Poles
(Contactors Only)
NEMA
Page
Class
Contactors
Reversing Contactors
FVNR Starter, Non-combination
Reversing, Non-combination
FVNR Non-combination, with CPT
Single-Phase FVNR (Freedom Only)
Combination with Disconnect Switch
Reversing, Combination with Disconnect Switch
Combination with Disconnect Switch, with CPT
Combination with HMCP/E
Reversing, Combination with HMCP/E
Combination with HMCP/E with CPT
Multispeed 2S2W Non-combination
Multispeed 2S1W CT or VT Non-combination
Multispeed 2S1W CH Non-combination
Multispeed with Disconnect Switch, 2S2W
Multispeed with Disconnect Switch, 2S1W CT or VT
Multispeed with Disconnect Switch, 2S1W CH
Multispeed with HMCP/E, 2S2W
Multispeed with HMCP/E, 2S1W CT or VT
Multispeed with HMCP/E, 2S1W CH
Autotransformer, Non-combination
Autotransformer, with Disconnect Switch
Autotransformer, with HMCP/E
Part-Winding, Non-combination
Part-Winding, with Disconnect Switch
Part-Winding, with Circuit Breaker
Y-D, Open Transition, Non-combination
Y-D, Open Transition, with Disconnect Switch
Y-D, Open Transition, with Circuit Breaker
Y-D, Closed Transition, Non-combination
Y-D, Closed Transition, with Disconnect Switch
Y-D, Closed Transition, with Circuit Breaker
Std Width Pump Panel, with Disconnect Switch
Std Width Pump Panel, with HMCP/E
Autotransformer Pump Panel, Disconnect Switch
Autotransformer Pump Panel, HMCP/E
Part-Winding Pump Panel, Disconnect
Part-Winding Pump Panel, Circuit Breaker
Duplex, Non-combination
Duplex, with Disconnect Switch
Duplex, with HMCP/E
a
a
Coil Voltage and/or Control Transformers
33-53
33-55
33-57
(See Tables Below)
Disconnect Fuse Clip Ratings
a
33-58
33-62
33-65
33-67
33-69
33-71
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
1
2
3
4
5
6
7
8
9
A
0
1
2
3
4
ABCDEF-
None
3A
7A
15A
30A
50A
GHJKLM-
100A/600V R
200A/250V R
200A/600V R
400A/250V R
400A/600V R
600A/250V R
600A/600V R
800A/600V L
1200A/600V L
1600A/600V L
2000A/600V L
by Description
NPQRST-
-
-
GHJKLM-
100A
150A
250A
400A
600A
800A
NPQRT-
1000A
1200A
2000A
3000A
by Description
56789I-
3Ab
7Ab
15Ab
30Ab
50Ab
100Ab
Enclosure Types
Type 1 – General Purpose
Type 3R – Rainproof
Type 4 – Watertight (Painted Steel)
Type 4X – Watertight (Stainless Steel)
Type 4X – Corrosion (nonmetallic) (Section 9)
Type 7/9 – Bolted Hazardous Location (Section 8)
Type 7/9 – Threaded Hazardous Location (Section 8)
Type 12 – Dust-Tight
Type 12 – Dust-Tight with Safety Door Interlock
NEMA Size
Size 00
5 Size 0
6 Size 1
7 Size 2
8 Size 3
9 Size 4
Size 5
Size 6
Size 7
Size 8
Size 9
Table 33-104. Control Power Transformer Codes (System Voltage)
3
Code
Magnet Coil
Code
Magnet Coil
Code
Magnet Coil
A
B
C
D
E
G
H
J
120/60 110/50
240/60 220/50
480/60 440/50
600/60 550/50
208/60
550/50
277/60
208 – 240/60
K
L
M
P
Q
R
S
T
240/50
380/50
415/50
12V DC
24V DC
48V DC
125V DC
24/60
U
V
W
X
Y
Z
24/50
32/50
48/60
104 – 120/60
48/50
By Description
3
None
30A/250V R
30A/600V R
60A/250V R
60A/600V R
100A/250V R
HMCP or Breaker Ratings
Refer to Enclosed Control Product Guide, P.G.3.02.T.E.
Use for Sizes 0 – 3, HMCP 600V applications only.
Table 33-103. Magnetic Coil Codes (System Voltage)
ABCDEF-
When control power transformer modification codes (C1 – C11) are
used or when starter class includes CPT (i.e. ECN07, 18) see table to the
right for system voltage code.
Code
Primary
Secondary
B
C
D
E
H
240/480 – 220/440 Wired for 240V
240/480 – 220/440 Wired for 480V
600/60 – 550/50
208/60
277/60
120/60 – 110/50
120/60 – 110/50
120/60 – 110/50
120/60
120/60
L
M
Q
R
S
380/50
415/50
208/60
240/480 – 220/440 Wired for 240V
240/480 – 220/440 Wired for 480V
110/50
110/50
24
24
24
T
U
V
W
X
600/60
277/60
380/50
415/50
240/480/600 Wired for 480V
24
24
24
24
120
Y
Z
240/480/600 Wired for 480V
By Description
24
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CAT.201.01.T.E
Tab3302.fm Page 50 Monday, October 23, 2000 10:07 PM
Back To Welcome
Contents
NEMA Contactors & Starters
3-Phase Magnetic Starters — Enclosed
33-50
January 2001
Vol. 2, Ref. No. [0066]
Freedom/Advantage/IT Lines
Cover Control
Factory Installed Pilot Devices
Non-reversing
33
Flange Control Kits
For on-the-job conversion of NEMA 1, 3R,
4X and 12 enclosed starters. Knockouts
are provided on the NEMA 1 flange.
NEMA 3R, 4X and 12 have prepunched
holes with removable hole plugs.
To order factory installed pilot devices,
change the 9th character of the
Catalog Number to the alpha shown
in the table below. Example: to order
an ECN0514CAA with START/STOP
pushbuttons and a red pilot light,
change the A to a C, i.e. ECN0514CCA.
Figure 33-23.
Figure 33-24.
Table 33-100. Non-reversing Pilot Devices
Description
Non-combination
NEMA 1, Sizes 5 – 9
NEMA 1, Sizes N – V
All NEMA 3R, 4X, 12
All IT Soft Starts
Combination
Freedom NEMA only 1
Advantage 2
IT
Cover Mounted Field
Installation Kits 4
See Figure 33-24
Non-combination
Sizes 00 – 4
Sizes A – M
NEMA/IEC Freedom Series
NEMA 1 Enclosure only
Cover Mounted Field
Installation Kits 4
See Figure 33-23
Catalog
Number
No Cover Mounted Pilot Devices
START/STOP Pushbuttons
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
C400GK0
C400GK1
C400GK12 3
C400GK16 3
ON/OFF Pushbuttons
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
—
—
—
HAND/OFF/AUTO Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
Price
U.S. $
Catalog
Number
7.
55.
155.
252.
—
C400T1
—
—
Factory Installed Flange Control
Position
9 Alpha
Price
U.S. $
—
55.
—
—
NEMA 1 only
Sizes 00 – 4
Sizes A – M
Non-combo.
only 3
NEMA 1
Sizes 5 – 9
Sizes N – V
NEMA 3R,
4X, 12 2
All
Combination
See
Figure 33-23
See
Figure 33-24
Adder
U.S. $
Adder
U.S. $
A
B
C
D
—
77.
204.
333.
—
159.
315.
472.
— C400T2
— —
— —
55. E
— F
— G
—
—
—
159.
315.
472.
C400GK3
C400GK32 3
C400GK36 3
55. C400T12
155. —
252. —
55. H
— J
— K
77.
204.
333.
159.
315.
472.
START Pushbutton
ON Pushbutton
OFF Pushbutton
Red RUN Pilot Light
Green OFF
Red RUN/Green OFF Pilot Lights
—
—
—
C400GK42 3
C400GK41 3
C400GK46 3
—
—
—
101.
101.
201.
L
M
N
P
Q
R
—
—
—
129.
129.
257.
159.
159.
159.
159.
159.
315.
START/STOP Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
—
—
—
— C400T13
— —
— —
55. S
— T
— U
—
—
—
159.
315.
472.
ON/OFF Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
—
—
—
— C400T14
— —
— —
55. V
— W
— X
—
—
—
159.
315.
472.
1
2
3
For IEC Combination Cover Control, see Page 34-71.
For ACM Cover Control Option, see Page 33-101.
Add Code Letter from the table below to Catalog Number for voltage — Kits only.
Example: C400T9B.
Local Control Options (If Used)
Refer to Diagram Inside Enclosure for Connections
Figure D
Pilot Light (Motor RUN)
S.P.S.T.
Switch
Code Letter
Rating
Code Letter
Rating
Code Letter
120V 60 Hz
208V 60 Hz
A
E
240V 60 Hz
380V 50 Hz
B
L
480V 60 Hz
600V 60 Hz
C
D
Additional Kits available. See Page 11-19 of P.G.3.02.T.E.
39.
39.
39.
101.
101.
201.
Figure A
START/STOP Pushbutton
Rating
Note: 120V only for Advantage.
4
C400T3
C400T4
C400T5
C400T9 3
C400T10 3
C400T11 3
Figure F
Overload Tripped
Black “A1”
Start
Black 3/14
Black “A2”
Yellow 2/13
Black
Stop
Red 1
Figure E
START/STOP
with Pilot Light
Black 3/14
Hand
Yellow - to Coil
A1 Terminal
Red 1
1
97
Figure B
2-Position Selector Switch
S.P.S.T.
Switch
Auto
Black
98
Black “A1”
Black “A2”
Start
Black 3/14
Stop
Yellow
2/13
OL
96
Reset
95
Wire “C”
Red 1
Figure C
3-Position Selector Switch
Figure G
Pilot Light (Motor STOP)
Remove Lead from
Coil to Terminal Number 3
Remote
S.P.S.T.
Switch
Switch
L1, X1 or 1
Connect to
OL Terminal
No. 96
1
Auto
OFF
Hand
or
Test
Black 3/14
1
Stop
Yellow - to Coil
A1 Terminal
NC Interlock
(If Used)
Red 1
Figure 33-25. Wiring Diagrams
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-1C
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CAT.201.01.T.E
Tab3302.fm Page 53 Monday, October 23, 2000 10:07 PM
Back To Welcome
Contents
NEMA Contactors & Starters
3-Phase Magnetic Starters — Enclosed
January 2001
33-53
Vol. 2, Ref. No. [0069]
Freedom Line
Product Selection — Non-combination Starters
Full Voltage
Interchangeable Heater OLR
■ 600V Maximum
■
■
33
Table 33-105. Class ECN05 — NEMA — Non-combination — Non-reversing
Motor
Voltage
Max.
hp
Rating
1
Magnet
Coil
Voltage
3-Pole, NEMA 1
General Purpose
Catalog
Number
3-Pole, NEMA 3R
Rainproof
Price
U.S. $
Catalog
Number
Price
U.S. $
3-Pole, NEMA 4X 3
Watertight &
Dust-Tight
Stainless Steel
3-Pole, NEMA 12
Dust-Tight Industrial
External Reset
(NEMA 3R) 2
Catalog
Number
Catalog
Number
Price
U.S. $
Price
U.S. $
NEMA Size 00
—
200
230
460
575
—
1-1/2
1-1/2
2
2
120
208
240
480
600
ECN05A1AAA
ECN05A1EAA
ECN05A1BAA
ECN05A1CAA
ECN05A1DAA
195.
195.
195.
195.
195.
120
208
240
480
600
ECN0501AAA
ECN0501EAA
ECN0501BAA
ECN0501CAA
ECN0501DAA
242.
242.
242.
242.
242.
ECN0502AAA
ECN0502EAA
ECN0502BAA
ECN0502CAA
ECN0502DAA
322.
322.
322.
322.
322.
ECN0504AAA
ECN0504EAA
ECN0504BAA
ECN0504CAA
ECN0504DAA
477.
477.
477.
477.
477.
ECN0508AAA
ECN0508EAA
ECN0508BAA
ECN0508CAA
ECN0508DAA
322.
322.
322.
322.
322.
120
208
240
480
600
ECN0511AAA
ECN0511EAA
ECN0511BAA
ECN0511CAA
ECN0511DAA
275.
275.
275.
275.
275.
ECN0512AAA
ECN0512EAA
ECN0512BAA
ECN0512CAA
ECN0512DAA
354.
354.
354.
354.
354.
ECN0514AAA
ECN0514EAA
ECN0514BAA
ECN0514CAA
ECN0514DAA
520.
520.
520.
520.
520.
ECN0518AAA
ECN0518EAA
ECN0518BAA
ECN0518CAA
ECN0518DAA
354.
354.
354.
354.
354.
120
208
240
480
600
ECN0521AAA
ECN0521EAA
ECN0521BAA
ECN0521CAA
ECN0521DAA
550.
550.
550.
550.
550.
ECN0522AAA
ECN0522EAA
ECN0522BAA
ECN0522CAA
ECN0522DAA
690.
690.
690.
690.
690.
ECN0524AAA
ECN0524EAA
ECN0524BAA
ECN0524CAA
ECN0524DAA
1,025.
1,025.
1,025.
1,025.
1,025.
ECN0528AAA
ECN0528EAA
ECN0528BAA
ECN0528CAA
ECN0528DAA
690.
690.
690.
690.
690.
120
208
240
480
600
ECN0531AAA
ECN0531EAA
ECN0531BAA
ECN0531CAA
ECN0531DAA
910.
910.
910.
910.
910.
ECN0532AAA
ECN0532EAA
ECN0532BAA
ECN0532CAA
ECN0532DAA
1,085.
1,085.
1,085.
1,085.
1,085.
ECN0534AAA
ECN0534EAA
ECN0534BAA
ECN0534CAA
ECN0534DAA
1,585.
1,585.
1,585.
1,585.
1,585.
ECN0538AAA
ECN0538EAA
ECN0538BAA
ECN0538CAA
ECN0538DAA
1,085.
1,085.
1,085.
1,085.
1,085.
(Select Starter from Size 0 Listing)
NEMA Size 0
—
200
230
460
575
—
3
3
5
5
NEMA Size 1
—
200
230
460
575
—
7-1/2
7-1/2
10
10
NEMA Size 2
—
200
230
460
575
—
15
25
25
—
NEMA Size 3
—
200
230
460
575
—
25
30
50
50
Starters do not include heater packs. Select 1 carton of 3 heater packs. For Heater Pack Selection, see Pages 33-36 – 33-37.
1
2
3
Maximum horsepower rating of starters for 380V 50 Hz applications:
NEMA Size
00
0
1
2
3
4
5
6
Horsepower
1-1/2
5
10
25
50
75
150
300
Suitable for outdoor application when properly installed — see Page i-5 of P.G.3.02.T.E.
NEMA 4X (Stainless steel) Sizes 0 – 6, NEMA 4 (Painted steel) Sizes 7 – 9.
Note: Reference to Enclosed Control
Product Guide — PG.3.02.T.E.
Description
Page
Accessories, Kits
Wiring Diagrams
Dimensions
11-1 to 11-11
1-77 to 1-85
12-1 to 12-24
Technical Data
Multi-Speed
14-1 to 14-8
1-28 to 1-30
Catalog Number ECN0511CBA
Cover Mounted Control . . . . . Page 33-50
Modifications/
Accessories . . . . . . . . . . . . . . Pages 33-41 – 33-49
Discount Symbol . . . . . . . . . . . 1CD-1C
CAT.201.01.T.E
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Back To Reference
Contents
Freedom Pump Panels
Motor Circuit Switch
February 1999
6-3
NEMA 3R Enclosure / 3-Phase Magnetic / Interchangeable Heater OLR Description
the enclosure and are wired as illustrated in the diagram below right.
Narrow Width Fuse Clip
Rating Standard Width Motor
Voltage Max. hp
50/60 Hz
NEMA
Size
Amperes
Volts
Catalog Number
Catalog Number
230
460
—
7-1/2
10
—
1
30
30
Not Installed
250
600
Not Installed
ECN5412BAB-E14
12CAC-E14
12AAA-E14
ECN5412BAB
12CAC
12AAA
230
460
—
15
25
—
2
60
60
Not Installed
250
600
Not Installed
ECN5422BAD-E14
22CAE-E14
22AAA-E14
ECN5422BAD
22CAE
22AAA
230
460
—
30
50
—
3
100
100
Not Installed
250
600
Not Installed
—
—
—
ECN5432BAF
32CAG
32AAA
230
460
—
50
100
—
4
200
200
Not Installed
250
600
Not Installed
—
—
—
ECN5442BAH
42CAJ
42AAA
230
460
100
200
5
400
400
250
600
—
—
ECN5452BAK
52CAL
230
460
200
400
6
600
600
250
600
—
—
ECN5462BAM
62CAN
460
600
7
1200
600
—
ECN5472CAQ
*
Narrow Width
Size 2 NEMA 3R
Typical Wiring Diagram
L1
Starters do not include heater packs. Select 1 carton of 3 heater packs. Heater pack selection, Page 14-4.
Does not include top conduit hubs. Hubs are available in kit form — see Page 6-9.
If branch circuit protective device is 45A or greater, C320FBR1 fuse kit (panel mounted) may be
required for control circuit protection per NEC 430-72.
Dual element fuse ratings.
Class R fuse clips, except for Size 7 which uses Class L fuse clips. For starters with clips “Not
Installed”, select fuse clip kit from table below.
To order without the START pushbutton, add mod code P6.
L2
L3
Circuit
Breaker or
Motor Circ.
Switch
Hand
OFF
Auto
Standard ECN54 controllers have a
HAND/OFF/AUTO selector switch
and START pushbutton mounted on
M
Pressure Switch
OL
C351 — Fuse Clip Selection — 3-Pole (3 Fuses)
NEMA
Size
Motor
Voltage
Fuse Clip
Rating
Amperes
Fuse Clip Kit for Field Installation in
Non-fusible Starter
Volts
For Non-rejection
Type Fuses
200/230
460 – 575
30
30
250
600
C351KC21
KD22-61
C351KC21R
KD22-61R
$ 12.60
15.70
2
200
230
460 – 575
60
60
60
250
250
600
C351KD22-61
KD22-61
KD62
C351KD22-61R
KD22-61R
KD62R
15.70
15.70
18.80
200
230
460 – 575
100
100
100
250
250
600
C351KE23-63 KE23-63 KE23-63 66.00
200
230
460 – 575
200
200
200
250
250
600
C351KF24-64 KF24-64 KF24-64 101.00
4
Fuse clip “R” rejection members for use with Class R fuses are supplied loose both in Fuse Clip
Kits and when fuse clips are factory installed.
■
UL Listed — File #E1491, Guide
NLDX.
Dimensions
Accessories, Kits
Modifications
PG.3.02.T.E
Page 12-6
Pages 11-1 – 11-9
Pages 11-16 – 11-23
M
For Other Volts and Hertz
Applications
For other than listed volts and hertz,
select required controller by catalog
number and replace the magnet coil
alpha designation, 8th digit in catalog number with proper code suffix
from table below.
Example: For 600V 60 Hz coil, change
ECN5412BAC to ECN5412DAC.
Coil Volts and Hertz
UL
M OL
Motor
For use with “R”
Rejection
Type Fuses
1
3
T3
T1
Catalog Number
Start
T2
Price
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
600/60 or 550/50
208/60
Code Suffix
A
B
C
D
E
*Prices — Consult Factory
Discount Schedule 1CD-1C
Back To Reference
Contents
Freedom and Advantage Pump Panels
3-Phase Magnetic / Irrigation Pump Control
6-2
February 1999
Motor Circuit Switch or HMCP Circuit Breaker
Features
The Freedom Series and Advantage
starters are available in either fusible
or circuit breaker types utilizing
NEMA 3R Rainproof and Sleet Resistant enclosures. Convenient straightthrough wiring with top line connections and bottom load connections
features easily accessible pressure
connections for line, load and control. Starter and disconnect are factory wired. Freedom overload relays
with trip indication feature bimetallic
type operation with ambient compensation and a choice of either
manual or automatic reset.
■
■
■
■
■
Motor Circuit Switch — Long life,
heavy-duty, quick acting, double
break action. Positive ON and positive OFF available in either fusible
or non-fusible versions. Fuse clip
kits are available for field installation and can be converted in the
field for maximum job flexibility.
Motor Circuit Protector — Similar
to a magnetic trip only circuit
breaker. Features an adjustable
magnetic trip characteristic for
accurate, dependable fault protection and simultaneous trip of all
poles to prevent single phasing.
HAND/OFF/AUTO Selector
Switch and START Pushbutton —
10250T heavy-duty units mounted
on the flange of the enclosure for
outside accessibility.
RESET Button — Accessible from
front of enclosure (booted for
environmental protection) for
operation of overload relay reset
function.
Enclosure — NEMA 3R Rainproof
and Sleet Resistant construction
with stainless steel door latches
and special corrosion resistant
paint. Enclosure features include
grounding lugs, padlocking feature on door latch, drip hood over
door and provisions for top
mounting conduit hubs. Most
enclosures include generous
panel space for mounting optional
control and accessories.
■
Mounting — Pole mounting feet
with keyhole slots for easy mounting are standard on enclosures for
Sizes 1 – 5 (removable for Sizes
1 – 5 standard width flange type
enclosures). Brackets can be
formed to the contour of the pole
after mounting.
■
Padlocking — Provision on door
latch for locking door closed, as
well as provision for padlocking
disconnect switch in OFF position.
With a simple modification, disconnect can also be padlocked in
ON position.
■
UL Listed — Underwriters Laboratories Inc. listed under File E1491,
guide NLDX, includes the “Suitable for Use as Service Equipment” label.
Interrupting Ratings
■ Fusible — Sizes 1 – 5 suitable for
use on a circuit capable of delivering not more than 100,000 rms
symmetrical amperes. 600V maximum where a Class R fuse clip kit
is properly installed and Class R
fuses are used. If Class R fuses are
not used, the switch should not be
installed on circuits capable of
delivering more than 10,000 rms
symmetrical amperes. Size 6 is
limited to 18,000 and Size 7 is limited to 30,000 rms symmetrical
amperes.
■
■
Circuit Breaker HMCPE — Sizes 1
– 3 controllers are suitable for use
on circuits capable of delivering
not more than 100,000 rms symmetrical amperes at 480V maximum; for 600V applications, see
below.
Circuit Breaker HMCP — Sizes 4 and
5 controllers are suitable for use
on circuits capable of delivering
not more than 100,000 rms symmetrical amperes at 480V maxi-
mum; Sizes 1 and 2 are suitable for
use on circuits capable of delivering
not more than 25,000 rms symmetrical amperes at 600V maximum; and Sizes 3 and 4 are
suitable for use on circuits capable
of delivering not more than 50,000
rms symmetrical amperes at 600V
maximum. Size 5 is suitable for
use on circuits capable of delivering not more than 35,000 rms
symmetrical amperes at 600V
maximum. Size 6 is limited to
18,000 and Size 7 is limited to
30,000 rms symmetrical amperes.
Optional Features
■
Backspin Timer — .2 seconds to 3
minutes. Prevents restart until
motor and pump have stopped.
■
Program Timer — 24 hour, 7 day
with day omission.
■
Control Transformer — Available
as standard, either as a field kit or
factory installed. Includes 2 primary and 1 secondary fuses.
■
Electrical Interlocks — Side
mounted in NO, NC and NO-NC.
Maximum of 2 contacts on either
side of starter through Size 2,
maximum of 3 per side Sizes 3 – 5.
■
Control Circuit Fuse Kit — 30A,
600V rating.
■
Lightning Arrestor — Offers protection to control from lightning
induced surges.
■
“R” Fuse Clip Kits — 30 – 200A,
250V and 600V ratings.
■
Disconnect Control Circuit Interlock — To disconnect separate
control circuits.
■
Enclosure Conduit Hubs — Hole
provided in enclosure top covered
with hole closer. Will accept 3/4",
1-1/4", 1-1/2", 2", 2-1/2" and 3" conduit sizes.
■
Pad Mounting Feet — For standard width enclosures Sizes 1 – 5.
PG.3.02.T.E
Back To Reference
Contents
February 1999
Freedom and Advantage Pump Panels
3-Phase Magnetic / Irrigation Pump Control
6-1
Motor Circuit Switch or HMCP Circuit Breaker
Table of Contents
Description
Page
Description . . . . . . . . . . . . . . . . . 6-1
Freedom Pump Panels . . . . . . . . 6-3
Vacuum Pump Panels . . . . . . . . . 6-6
Advantage Pump Panels . . . . . . 6-7
Optional Features . . . . . . . . . . . . 6-9
Description
NEMA 3R with Cutler-Hammer
Size 1 – 3 Starter
NEMA 3R Enclosure, Narrow,
with Cutler-Hammer
Size 1, 2 Starter
NEMA 3R Part Winding
Pump Panel, Size 3
PG.3.02.T.E
The irrigation pump controllers are
combination starters with accessories and modifications designed to
meet the particular requirements of
the irrigation, pumping and oil well
industries. The enclosure is NEMA
3R to provide weathertight protection and is available in several sizes,
depending on the customer’s control
or control option requirements. The
disconnect, contactor and overload
relay are the same as used in Freedom Series and Advantage combination starters. In Freedom Series
versions, this includes the innovative overload feature that allows
conversion from Class 20 to Class 10
by merely inserting different heater
packs. These controllers are available in standard full voltage as well
as reduced voltage configurations,
with vacuum contactors as well as
the standard electromechanical
contactors.
Download