20MHz Analog Oscilloscope+function Generator Handheld Digital Storage Oscilloscope & Multimeter The GDS-122 is a reliable and handy instrument for all test and electronic engineers. This model is designed to carry out complicated on-site tests. The Dual-channel unit provides 20MHz of bandwidth with a sampling rate of 100MS/s with additional DMM functionality. The color LCD display with a 320 x 240 resolution helps you to read waveforms easily, especially when displaying a lot of data or multiple waveforms. The compact design with a total weight of 690g allows engineers to carry it around easily. The unit's protective cover is insulated and specially designed to endure tough environments. A rechargeable Li-ion battery ensures convenience for on-site testing. The GOS-620FG is a general purpose analog oscilloscope with a 20MHz bandwidth. Aside from the basic functions, such as 1mV/div~5V vertical sensitivity, 0.2uS/div~0.5S/div horizontal sweep time, and practical Auto/Norm/TV-V/TV-H trigger modes, the GOS-620FG offers extra function generating features required for most class experiments and electrical production lines. The affordably priced GOS-620FG is capable of generating Sine/Square/Triangle waveforms in the frequency ranges from 0.1Hz~1MHz (7 range) with sine wave distortion as low as 2%. SPECIFICATIONS GDS-122 (20MHz) FEATURES SPECIFICATIONS OSCILLOSCOPES * Built-In 1 MHz Function Generator * 20MHz Bandwidth, Dual Channel * High Sensitivity 1mV/div * ALT Triggering Function * TV Synchronization * CH1 Output * Z Axis Input * Economic Choice for High Quality CRT Type Accelerating Potential Z-Axis Input Polarity Focus Control FUNCTION GENERATOR Frequency Range Waveform Frequency Variable Range Output Impedance Voltage Sinewave Distortion Squarewave Unsymmetry Squarewave Rise/Fall Time VERTICAL SYSTEM Sensitivity Bandwidth Rise Time Max. Input Input Coupling Input Impedance Vertical Mode HORIZONTAL SYSTEM Sweep Time Max. Sweep Rate TRIGGER Trigger Mode Trigger Source Trigger Slope X-Y OPERATION Sensitivity X-axis Bandwidth Phase Error OUTPUT SIGNAL Trigger Signal Output Calibrator Output 6-inch rectangular type with internal graticule ; 8 x 10 div (1div=1cm) 2kV Sensitivity: Above 5Vp-p ; Max. input voltage : 30V (DC + AC peak) Bandwidth: DC ~ 2MHz Positive-going input decrease Auto focus 0.1Hz ~ 1MHz (7 range) Sine Wave, Square Wave, Triangle Wave 10:1 or more _10% 50 + Over 20Vp-p(open circuit)continuous conversion _ 10V when open DC offset possible over + 1% Max. (10Hz ~ 20kHz) _ 3% or less (in 1 kHz maximum) + 50 output: 120ns or less _5%(using x 5MAG.) _ 3%,1mV/div~1V/div + 5mV/div~5V/div + DC to 20MHz (x 5MAG.:DC to 7MHz) Approx. 17.5ns (x 5MAG.:Approx. 50ns) 300V (DC+ACpeak) at 1kHz AC, DC, GND Approx. 1M // 25pF CH1,CH2,DUAL(ALT,CHOP),ADD,CH2 INV _ 3% (+ _ 5% at x 10MAG) 0.2 s/div ~ 0.5s/div + 100ns/div (20ns and 50ns/div are uncalibrated) FEATURES * 20 MHz Bandwidth * 100 MS/s Real-Time Sampling Rate * Digital Storage Oscilloscope & Multimeter * True RMS Multimeter Volts, Amps, Ohms, Continuity, Diode * Dual Independent Floating Isolated Channels (for Multimeter and Between Oscilloscope and Multimeter) * Trigger Mode : Free Run, Single Shot, Edge, Video * USB Interface * 4 Hour Capacity Li-ion Rechargeable Battery * 3.8" Color LCD, Resolution: 320 × 240 * Light Weight at 690g PACKAGE CONTENTS Extension module for large current measurement Oscilloscope probe AUTO, NORM, TV-V, TV-H CH1, CH2, ALT, LINE, EXT " + " or " - " _ 4% 5mV ~ 5V/div + DC ~ 500kHz 3。or less from DC ~ 50kHz Extension module for small capacitance measurement Multimeter test lead Voltage : approx. 20mV/div into 50 W Bandwidth : 50Hz to 5MHz (-3dB) Impedance : Approx. 50 W 1kHz Square wave, 2Vp-p 2% POWER SOURCE _ 15%, 50/60Hz AC 115/230V + DIMENSIONS & WEIGHT AC-DC adaptor 310(W) x 150(H) x 455(D)mm; Approx. 8.5kg HORIZONTAL Sampling Rate Range Waveform Interpolation Record Length Scanning Speed Range S/div Sampling Rate and Relay Time Accuracy Time Interval (T)Measurement Accuracy Full Bandwidth 10S/s~100MS/s sin x / x 6K points on each channel 5ns/div 5s/div, stepping in the “1-2.5-5” mode. ±100ppm(any time interval which is equal to or larger than 1ms) Single: ±(1 sampling interval time+100ppm×reading+0.6ns) >average 16 : ±(1 sampling interval time +100ppm×reading+0.4ns) INPUT Input Coupling Input Impedance Probe Attenuation Coefficient Max. Input Voltage Channel Delay Time (Typical) SAMPLING Sampling Modes Sampling Rate MEASUREMENT Cursor Measurement Auto Measurement MULTIMETER SPECIFICATIONS Input Impedance Voltage Max Input VAC Frequency Max Input Current Capacitance Diode GENERAL SPECIFICATIONS Display DC, AC 1MΩ±2% connected in parallel with 20pF±3pF 1X, 10X, 100X, 1000X 400V (peak) 150ps Normal sampling Peak detection Average value 100 MSa/s Voltage difference (V) and time difference (T) between cursors Peak-to-peak value,average value,root mean square value,frequency and cycle 10MΩ VDC: 400mV, 4V, 400V ±(1% +1 digit) DC 400V 4V, 40V, 400V ±(1% +3 digit) 40Hz ~ 400Hz AC 400V (Virtual value) DCA : 40mA, 400mA ±(1.5% +1 digit); 20A: ±(3% +3 digit) DAA : 40mA ±(1.5% +3 digit), 400mA ±(2% +1 digit); 20A: ±(5% +3 digit) 400Ω ±(1%+3 digit), 4KΩ, 40KΩ, 400KΩ, 4MΩ ±(1%+1 digit), 40MΩ ±(1.5%+3 digit) 51.2nF ~ 100uF ±(3%+3 digit) 0V ~ 1.5V On/Off measurement < 50 (±30) beeping Display type : 3.8" color liquid crystal display Display resolution : 320 (horizontal) × 240 (vertical) pixels Display color : 4096 colors Power supply : 100-240 VACRMS, 50Hz, CAT II ; Power consumption : < 6W Used battery : 0~50 °C (32~122 °F);Power adapter : 0~40 °C (32~104 °F) DIMENSION & WEIGHT 115(W) x 180(H) x 40(D) mm ; Approx. 0.69kg GOS-620FG 20MHz Oscilloscope with Built-in 1MHz Function Generator 1kHz square wave output cable USB communication cable ORDERING INFORMATION GDS-122 OPTIONAL ACCESSORIES GTC-001 Instrument Cart, 450(W) x 430(D) mm GTC-002 Instrument Cart, 330(W) x 430(D) mm GTL-110 Test Lead, BNC-BNC Heads DC coupling : 1div (full bandwidth) AC coupling : Same as the DC coupling > 50Hz ±6 divs from the screen center ±0.3 divs (typical) 655 divs (pre-trigger), 4 divs (post-trigger) Input signal frequency > 50Hz 2 divs of peak-to-peak value Supports NTSC, PAL and SECAM, any or line frequency Power Adapter Operating Temperature ORDERING INFORMATION ACCESSORIES : User manual x 1, Power cord x 1 Probe-GTP-020A-4 : 20MHz ( 10 : 1/1 :1 ) Switchable Passive Probe (one per channel) Test Lead GTL-101 x 1 Trigger Level Trigger Level Accuracy Trigger Displacement 50% Level Setting Trigger Sensitivity Video Trigger Impedance Soft carrying case 8 bits simultaneously sampling on both channels 5mV/div 5V/div at the input BNC ±50V (500mV ~ 5V), ±1V(5mV ~ 200mV) 20MHz Full bandwidth ±5Hz at the BNC input 17.5ns (typical) ±5% ±(5% reading + 0.05 div), at the Average sampling mode (> 16) OSCILLOSCOPES GOS-620FG GOS-620FG (20 MHz) Analog Digital Converter Resolution Sensitivity Displacement Range Analog Bandwidth Single Bandwidth Low Frequency Response AD Coupling,-3dB Rise Time DC Gain Accuracy DC Measurement Accuracy TRIGGER Trigger Sensitivity Edge Triggering GDS-122 VERTICAL CD-ROM(Software), User manual Handheld Digital Storage Oscilloscope & Multimeter ACCESSORIES : User manual, AC-DC Adaptor, Probe-T5060:60MHz(10:1/1:1)Switchabel Passive Probe (one per channel) Multimeter test lead, Serial data communication cable, Extension module for small capacitance measurement, Extension module for large current measurement FREE DOWNLOAD PC Software A41 Good Will Instrument Co., Ltd. Simply Reliable Simply Reliable Good Will Instrument Co., Ltd. A42