V1.15 Liquid Level Display Datasheet A-A. Tiimanni 1, 21004 Narva, Estonia. Tel.: +372 3569590, Fax: +372 3566292 , e-mail: info@omnicomm-online.com www.omnicomm-online.com All rights reserved. ©2015 OMNICOMM TABLE OF CONTENTS INTRODUCTION. .................................................................................................................................................... 2 USEABILITY. ........................................................................................................................................................... 3 SPECIFICATIONS. .................................................................................................................................................... 4 GENERAL VIEW. ..................................................................................................................................................... 5 LLD DIMENSIONS. .................................................................................................................................................. 6 CONNECTION SCHEME OF ONE OR MORE LLD VIA EIA-485 TO TWO (OR MORE) SENSORS LLS AND GPS/GPRS. .... 7 CONNECTION SCHEME OF LLD VIA RS-232 TO GPS/GPRS. ...................................................................................... 7 CONNECTION SCHEME OF LIQUID LEVEL SENSOR LLS WORKING OUTSIDE OF THE MONITORING SYSTEM. ........... 8 CONNECTION SCHEME OF LLD TO TWO SENSORS LLS (20160 AND 20230), CONNECTED TO DALCON. ................... 8 TECHNOLOGICAL CONNECTOR OF PRODUCT. ........................................................................................................ 9 CONNECTION SCHEME OF CONNECTION TO PC. .................................................................................................... 9 REVISION HISTORY............................................................................................................................................... 10 All rights reserved. ©2015 OMNICOMM 1 INTRODUCTION. Liquid Level Display hereafter referred to as “LLD”, is designed to display the information about current level of the fuel in the fuel tank of the motor vehicle, or motor fuel storage/transportation tank. It is possible to display one of the following values: fuel level in the first fuel tank (liters) by the first liquid level sensor (LLS); fuel level in the second fuel tank (liters) by the liquid level second (LLS); total fuel level in both fuel tanks (liters). LLD perceived data about the fuel level from the liquid level sensor (LLS), converts received data to the volume using the loaded calibration tables and displays the value of volume. No more than two liquid level sensors (LLS) can be connected to the LLD. Both sensors can be installed in one tank, this installation can be used for improving the measuring accuracy of the fuel level in the tank and compensate the slope of the tank. In the case if liquid level sensor LLS is adjusted to send data by symbol protocol, LLD will work only with one sensor LLS. There is a possibility adjust the LLD for displaying the fuel level in the tank in the metric units of length look at (“LLD installation manual”). All rights reserved. ©2015 OMNICOMM 2 USEABILITY. LLD can be used with: one or two liquid level sensors (LLS), connected via EIA-485 interface; one liquid level sensor (LLS), which connected with GPS/GPRS device via RS-232 interface; one liquid level sensor (LLS), which is not used conjunction with monitoring systems, connected via EIA485 and in the mode of periodical send data; one or two liquid level sensors (LLS), which is(are) included in the monitoring systems of other producers and connected via EIA-485 interface; one liquid level sensor (LLS), which is included in the monitoring systems of other producers; one or two liquid level sensors (LLS), which is(are) included in the monitoring systems of other producers and connected with DALCON. LLD can be used only with liquid level sensors (LLS), produced by OMNICOMM OU, has digital serial interface RS-232 and/or EIA-485, destined for sending data of measurement results. All rights reserved. ©2015 OMNICOMM 3 SPECIFICATIONS. Characteristic Value Comment Power supply, Volts DC +8,0 …..+45,0 Power, W No more 2 Dimensions, mm 137x61x23 Ingress protection IP41 Operation temperature, C -40,0 ….+70,0 Indication on the front panel light emitting diodes a seven segment indicator on four ranks and three LEDs Brightness Maximum/Minimum/Off 3 levels Displays volume 0 ….9999* Physical level EIA-485 for connection to PC (through REUSABLE TOOL -UNU) and for connection liquid level sensors LLS 20160 and LLS 20230 Speed of data transmission, bit per second 1200,2400,4800,9600,19200, default value is 19200 Weight, kg No more 0,2 Mode of operation continuous without connected cables 38400,76800,115200 *) If the volume of the fuel tank is more than 9999 liters we recommend to fill in the calibration table in dekaliters, so the value of volume, displayed on the LLD should be multiplied by ten, and the maximum volume will be 99990 liters (look at “LLD installation manual”). All rights reserved. ©2015 OMNICOMM 4 GENERAL VIEW. Figure 1. All rights reserved. ©2015 OMNICOMM 5 LLD DIMENSIONS. Figure 2. All rights reserved. ©2015 OMNICOMM 6 CONNECTION SCHEME OF ONE OR MORE LLD VIA EIA-485 TO TWO (OR MORE) SENSORS LLS AND GPS/GPRS. Figure 3. CONNECTION SCHEME OF LLD VIA RS-232 TO GPS/GPRS. Figure 4. All rights reserved. ©2015 OMNICOMM 7 CONNECTION SCHEME OF LIQUID LEVEL SENSOR LLS WORKING OUTSIDE OF THE MONITORING SYSTEM. Figure 5. CONNECTION SCHEME OF LLD TO TWO SENSORS LLS (20160 AND 20230), CONNECTED TO DALCON. Figure 6. All rights reserved. ©2015 OMNICOMM 8 TECHNOLOGICAL CONNECTOR OF PRODUCT. Figure 7. CONNECTION SCHEME OF CONNECTION TO PC. Figure 7. All rights reserved. ©2015 OMNICOMM 9 REVISION HISTORY. Date 02.03.12 11.09.13 14.09.15 Version 1.12 2.13 1.15 Description Initial Release Changed logo Changed company name All rights reserved. ©2015 OMNICOMM 10