Tellabs™ Sierra™ 200 Outside Plant Cabinet (Sierra™ 200)

TELLABS DATA SHEET
Tellabs™ Sierra™ 200 Outside Plant Cabinet
(Sierra™ 200)
The Tellabs™ Sierra™ 200 Outside Plant Cabinet (Sierra™ 200) is
an environmentally controlled enclosure supporting Tellabs 1000
Channel Bank Assemblies (CBAs) with fan shelves, protector
panels, charger/rectifier, and batteries. The Sierra 200 cabinet
line enables service providers to cost-effectively deploy high
densities of broadband services.
The Sierra 200 incorporates the latest environmentally controlled
design technologies to meet broadband demands for hardened
outside plant cabinets. It has been tested to GR-487 CORE, Issue
2 and has a documented level of performance with respect to
noise level, salt fog, transportation, dust and water intrusion. It
can support up to three Tellabs 1000 Integrated Multiservice
Access Platform (MSAP) CBAs with fan shelves, protector panels,
batteries and the Eltek charger/rectifier.
The cabinet’s front, rear and side doors are equipped with key
locks and padlock tabs. The side door provides controlled access
to the protector panels or the optional 2:1 feeder/distribution
cross-connect blocks in a two-shelf configuration. With a total
capacity of 360 lines, the Sierra™ 200 is designed for POTS or
heavy-broadband installations requiring optimal XDSL service
card capacity.
Tellabs™ Sierra™ 200 (Three-shelf configuration)
Sierra™ 200 Key Features
Optional generator connector
Environmental alarms
n
Telcordia-compliant design
n
n
Cross-connect to OSP facilities in a separate compartment
away from electronics
n
-48 VDC powered cooling fans
n
Cabinet height of 54 inches solves right-of-way costs and issues.
Vented separate battery compartment;
Removable battery base panels
n
n
Mechanical
Small size footprint
n
Battery backup options (see table on back page)
n
Standard AC surge protection
n
Hex key lock (padlockable for additional security)
n
MS connectors.
n
Fiber splice and distribution options
n
Dimensions: 54 in (H); 41 in (W); 27.8 in (D)
n
Weight: 520 lb (without batteries or plug-in cards)
n
Finish: smooth almond, no texture, powder coated
n
Cabinet mounting: pad or pole mount
n
n
2
Rack Widths: both bays are adjustable to 19 in or 23 in
Cable Entrances:
n
Copper line protection in separate compartment in
non-CC configurations
–Subscriber: 4 in x 3.5 in; Fiber: 1 in x 2 in; AC: 1 in x 2 in;
n
–Ground: 1 x 7/8 in
See Tellabs.com for more information about Tellabs Solutions
DATA SHEET
TELLABS™ SIERRA™ 200 OUTSIDE PLANT CABINET (SIERRA™ 200)
Security
Protector Panels
Equipment bays — standard telecom Hex L-key
150 pair AFC protector panels located in splice chamber for
non-cross-connect configurations and in the equipment rack for
cross-connect configurations
n
n
Splice bay — Bellcore 216 key
n
Thermal
Cross-Connect
Thermal capacity: 600 W (900 W with heat exchanger)
n
2:1 cross-connect with MS2 subscriber interface (2 CBA)
Heat exchanger fans activated at 30° C (86° F)
n
Fan trays — standard
n
n
Emerson URLs cross-connect blocks
n
900 cross-connects provided for Sierra 200-2CC
–Fans turn ON at 35° C (95° F), OFF at 30° C (86° F)
n
–Alarm activated on fan fail
Alarming
Alarms generated:
n
Acoustic
–Major: rectifier fail, LVBD contactor fail, LVBD contactor open
Complies with 65 dBA requirements of GR-487, Issue 2
n
–Minor: intrusion (door open), AC power fail, fan fail, high temp.
Electrical
Compliance
AC Input: 60 A Max, 110/220 VAC, 50/60 Hz, split single phase
n
UL 60950
n
DC Power: 1,300 W with N+1 redundancy
n
EN 60950
n
–Rectifier modules: 650 W/12 A
Telcordia GR-1089-CORE
Surge arrester: High-capacity Joslyn model 1265-21
n
Batteries (see table)
n
n
Batteries: Telcordia TR-NWT-00057
n
Surge Protectors: Telcordia GR-1361
n
–1 x 75 A battery breaker provided
Telcordia GR-487-CORE, Issue 2
n
Generator connectors
n
FCC Part 15, Subpart B
n
–60 A Hubbell pin/sleeve
–30 A NEMA
Mounting
Pad/pole
n
Depth
Depth
28.125
28.125
in in
71 cm
71 cm
Optional pour and place template or pole mount kit
n
Vendor
Vendor
PN
Fiamm
12FAT100
Hawker
PowerSafe
C&D
Dynasty
TEL
12-105F
GNB
M12V105FT
Hawker
EnerSys
SBS-60
6VF11
Battery
Type
Lead
Acid
Lead
Acid
Lead
Acid
Lead
Acid
Lead
Acid
Strings
Capacity
Terminal
(8-hr
Access
Rate)
1
100 Ah
Front
1
100 Ah
Front
1
100 Ah
Front
1
100 Ah
Front
3
153 Ah
Top
Radius
30.40
in in
Radius
30.40
77 cm
77 cm
Width
Width
41 in41 in
104 cm
104 cm
24.1324.13
in in
61 cm
61 cm
Height
Height
54.125
in in
54.125
137 cm
137 cm
Radius
30.40
in in
Radius
30.40
77 cm
77 cm
Take the next step. Contact Tellabs today.
+1 800 690 2324
+1 630 798 9900
www.tellabs.com
1415 West Diehl Road
Naperville, IL 60563
U.S.A.
TEL9512 1/15
© 2015, Tellabs Access, LLC. All rights reserved.
See Tellabs.com for more information about Tellabs Solutions