INMARSAT-C MOBILE EARTH STATION
FELCOM 15
Installation Manual
TABLE OF CONTENTS
EQUIPMENT LISTS......................................................................................................................ii
SYSTEM CONFIGURATION .......................................................................................................iii
1.
MOUNTING THE UNIT..........................................................................................................1
1.1 Antenna Unit.................................................................................................................1
1.2 Terminal Unit ................................................................................................................7
1.3 Distress Alert/Received Call Unit IC-305/Alarm Unit IC-306 ........................................9
1.4 Printer PP-510 (option)/EGC Printer PP-505 (option) ................................................10
1.5 AC/DC Power Supply Unit PR-240 (option) ...............................................................10
1.6 Junction Box IC-315 ...................................................................................................11
2.
WIRING ...............................................................................................................................12
2.1 Antenna Cable Connector at the Terminal Unit..........................................................13
2.2 Distress Alert/Received Call Unit IC-305....................................................................13
2.3 Alarm Unit IC-306 .......................................................................................................16
2.4 Junction Box IC-315 ...................................................................................................17
3.
INITIAL SETTING................................................................................................................18
3.1 Setting the IMN (INMARSAT MOBILE NO.)...............................................................18
3.2 Setting for External Equipment...................................................................................19
4.
INSTALLATION OF GPS BOARD (OPTION).....................................................................20
5.
CHANGING POWER SUPPLY SPECIFICATIONS ............................................................23
PACKING LISTS....................................................................................................................... A-1
OUTLINE DRAWINGS.............................................................................................................. D-1
INTERCONNECTION DIAGRAM ............................................................................................. S-1
www.furuno.co.jp
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
Telephone : +81-(0)798-65-2111
Fax
: +81-(0)798-65-4200
All rights reserved.
Printed in Japan
A : DEC . 2002
F : JUL . 10, 2009
Pub. No. IME-56350-F
(DAMI )
FELCOM15
*00080935115*
*00080935115*
* 0 0 0 8 0 9 3 5 1 1 5 *
SAFETY INSTRUCTIONS
CAUTION
WARNING
Do not open the equipment
unless totally familiar with
electrical circuits and
service manual.
Confirm that the power supply voltage
is compatible with the voltage rating
of the equipment.
Connection to the wrong power supply
can cause fire or equipment damage. The
voltage rating appears on the label at the
rear of the terminal unit.
ELECTRICAL Only qualified personnel
should work inside the
SHOCK
equipment.
HAZARD
Do not approach the radome closer than 60 cm
when it is transmitting.
Use the correct fuse.
Use 10 A fuse (defalt setting) for 12 VDC
power supply, or replace the fuse to 5 A
(supplied as spare parts) with 24 VDC.
Microwave radiation can
cause severe injury or illness.
Radiation level:
2
10 W/m at 60 cm
Use of wrong fuse can result in damage to
the equipment.
Turn off the power at the
mains switchboard before
beginning the installation.
Post a sign near the switch
to indicate it should not be
turned on while the equipment is being installed.
Keep the following compass safe
distances.
Standard Steering
Fire, electrical shock or
serious injury can result if the
power is left on or is applied
while the eqiuipment is being
installed.
Antenna Unit IC-115
0.30 m
0.30 m
Terminal Unit IC-215
0.70 m
0.40 m
Printer PP-510
1.00 m
0.80 m
Junction Box IC-315
1.00 m
0.70 m
Received Call Unit IC-305
0.50 m
0.30 m
Alarm Unit IC-306
0.50 m
0.30 m
EGC Printer PP-505
2.05 m
1.40 m
0.90 m
0.60 m
0.30 m
0.30 m
Distress Alert/
AC/DC Power Supply Unit
PR-240
Mini keyboard
Attach securely protection
earth to the ship's body.
The protection earth is required
to the power supply to prevent
electrical shock.
i
EQUIPMENT LISTS
Standard Supply
Name
Antenna Unit
Terminal Unit
Distress Alert/
Received Call Unit
Alarm Unit
Junction Box
Installation
Materials
Code No.
Qty
IC-115
IC-215
Type
-
1
1
IC-305
-
1
IC-306
IC-315
CP16-02101
CP16-02111
CP16-02121
004-439-060
004-439-070
004-439-080
1
1
CP16-02300
000-043-433
1 set
004-438-890
000-159-523-11
000-117-599
1 set
CP16-02201
TP5FBAW-5DFBB
8D-FB-CV
12D-SFA-CV
Accessories
FP16-00600
Spare Parts
SP16-01301
1 set
1
000-138-866
1 set
000-043-434
004-439-370
1 set
Remarks
w/CP16-02501*
For 30 m cable, antenna unit*
For 50 m cable, antenna unit*
For 100 m cable, antenna unit*
CP16-02301 (for IC-215)*,
CP16-02302 (for keyboard)*
For IC-305/306
30 m antenna cable
50 m antenna cable
100 m antenna cable
Mini keyboard (G84-4100PPAUS), FD
(FP16-00601)
Fuse*
Optional Supply
Name
FD-ROM
GPS Board
GPS Board Kit
RF Cover (GPS)
EGC Printer
Printer
AC/DC Power Supply Unit
Type
16-5-0164
OP16-47
OP16-48
OP16-49
PP-505
PP-510
PR-240
Code No.
004-438-920
001-017-110
000-011-766
000-011-767
000-560-452
000-103-868
000-103-869
000-132-829
000-132-828
Qty
1 set
1 set
1 set
1
1
1
1
5-pair cable
CO-SPEVV-SB-C
0.2x5P
SSAS Modification Kit**
OP16-33
000-043-492
1
SSAS Alert Unit**
IC-307
000-043-473
1
OP16-27
004-448-000
1
Flush Mounting Kit
1
Remarks
w/CP16-01200*
w/CP24-00151*
For junction box, 10m
For junction box, 20m
For junction box, 30m
For junction box, 40m
For junction box, 50m
IC-307 (2units), FD-ROM (for
RFCON CPU, for TERM CPU)
w/CP16-03101, FP16-00901
For distress alert/received call
unit, alarm unit
For SSAS alert unit
OP16-28
004-448-010
1
ALC (FFA) Modification Kit*
OP16-26
004-439-840
1
Russian Language Kit
OP16-43
004-449-590
1
For IC-215
PC Terminal Software
OP16-45
004-449-600
1
Russian Language
Antenna Mounting Kit
CP16-03701
004-555-000
1 set
Antenna Bracket
CP16-03702
001-016-260
1
See page D-14.
Antenna Mounting Pipe
CP16-03703
001-014-510
1
*: See packing lists at the back of this manual.
**: The SSAS modification kit is required for the SSAS. For installation of three IC-307s, additional SSAS
alert unit is necessary.
ii
SYSTEM CONFIGURATION
ANTENNA
UNIT
IC-115
DGPS
POWER SUPPLY
100-115/200-230 VAC
1φ, 50/60 Hz
AC-DC Power Supply
PR-240
TERMINAL UNIT
IC-215
POWER SUPPLY
12/24 VDC
GPS Board
OP16-47
EGC Printer**
PP-505
Personal
Computer
(PC/AT compatible)
24 VDC
Printer
Shipboard LAN (Ethernet)
Printer**
PP-510
* For 12 VDC power supply,
DC-DC converter is
required to use PP-510.
24 VDC
Mini Keyboard
Distress Alert/
Received Call Unit
IC-305
Distress Message Controller
DMC-5
JUNCTION
BOX
IC-315
OR
SSAS Alert Unit*
SSAS Alert Unit*
IC-307
IC-307
(Max. 3 units)
Navigator
*: At least two SSAS Alert Units are required.
**: Mandatory for EGC operation as required by IMO RES. A.664(16).
CATEGORY OF UNITS
Unit
Category
Terminal Unit
Protected from weather
Antenna Unit
Exposed to weather
Other Units
Protected from weather
Alarm Unit
IC-306
iii
: Standard Supply
: Option
: Local Supply
This page is intentionally left blank.
iv
1. MOUNTING THE UNIT
NOTICE
Do not apply paint, anti-corrosive sealant or contact spray to coating
or plastic parts of the equipment.
Those items contain organic solvents that can damage coating and plastic
parts, especially plastic connectors.
1.1
Antenna Unit
Mounting Location
• Mount the omnidirectional antenna unit high atop a mast clear of stays and the turning
diameter of a radar antenna. The ideal mounting location would be where no obstacle
appears in the fore and aft directions down to -5º and down to -15º in the port and
starboard directions. This concept is illustrated in the figure below. Shadow sector of the
antenna mast, whip antenna, etc. should be within 2 degrees at one meter from the
antenna unit.
ANTENNA UNIT
5
5
15
15
Antenna unit mounting location
• If both Inmarsat-B/F and Inmarsat-C ship earth stations are installed, separate the
Inmarsat-B/F antenna at least 8 m from the Inmarsat-C antenna.
• Separate the antenna unit from an S-band radar as follows:
Install above this line
INSTALLTION
ZONE
2m
1.5 m
15
PROHIBITED
ZONE
2m
5m
S-band radar
HORIZONTAL LINE
S-band radar and installation area
1
1. MOUNTING THE UNIT
• The allowable vibration level as specified by Inmarsat is as shown in the table below.
Allowable vibration level
Frequency
Level
2 to 10 Hz
2.54 mm Peak Amplitude
10 to 100 Hz
9.8 m/s² Peak Acceleration
• Avoid the location near funnels and stacks; smoke and soot on the radome can lower
signal level.
• Separate the antenna unit 5 m from HF, VHF or 27 MHz antenna.
Mounting
Thirty, 50 or 100 m antenna cable is available. Thirty meters cable has connectors on both
sides, and one connector for 50/100 m cable. Do not shorten these cables to prevent
interference. To mount the antenna unit, an exclusive pipe is necessary.
Note: To mount the antenna unit with the optional antenna mounting kit (Type: CP16-03701,
Code No.: 004-555-000), see page D-13.
20
1x14 UNS
35-S 12-S 25-S
Welding
25
.4
Antenna mast
Mounting pipe and antenna mast
2
6
50
,
Ground stud
Mounting pipe
,
100
Earth wire (340 mm)
200
12-S
Locally prepare an antenna mast with a ground stud (M6 stainless steel bolt welded to
antenna mast) and mounting pipe with threads and plate (See the outline drawing of the
mounting plate shown below.) Weld the mounting pipe to the antenna mast.
The distance between the stud and the earth terminal on the antenna unit should be within
340 mm, which also is the length of the supplied earth wire.
1. MOUNTING THE UNIT
For 15 or 30 m cable
1.
2.
3.
4.
5.
6.
7.
8.
9.
Apply silicone sealant (local supply) to the threads of the pipe.
Unscrew three screws to remove the antenna base from the antenna unit.
Pass the antenna cable through the pipe, antenna base in order.
Insert the cable protector (supplied) into the slot at the bottom of antenna base.
Screw the antenna base onto the antenna pipe by rotating the antenna base.
Pass the antenna cable into the shrink tube (SCM2, supplied).
Attach the antenna cable to the connector at the bottom of the antenna unit (upper).
Shift the shrink tube until it touches the bottom of the antenna unit (upper).
Heat the above shrink tube, and then apply silicone rubber around the upper edge of the
tube. Also wind self-bonding tape around the lower edge of the shrink tube and then
wrap vinyl tape over self-bonding tape.
Note: Between the bottom of the antenna unit (upper) and the end of the taping should be
less than 50 mm.
Antenna unit (upper)
Antenna base
Apply silicone sealant.
Antenna base, bottom view
Insert the cable
protector (wide side)
into this slot.
Cable protector
Silicone
rubber
less than
50 mm
Shrink
tube
(Inner) Shrink tube
(Outer) Vinyl tape
Antenna unit, passing the cable through the pipe
3
1. MOUNTING THE UNIT
10. Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%)
11. Wrap self-bonding tape around the connection of antenna base and pipe, and then wind
vinyl tape over self-bonding tape. These tapes should be winded closely.
12. Fix the earth wire RW-4747 (supplied) between the ground terminal on the antenna unit
and the ship’s ground point.
Ground terminal
Apply silicone rubber.
Taping
(self-bonding
tape and vinyl
tape)
Ship's ground point
Cable tie
(weatherproofed)
Mounting
13. Apply silicone rubber (supplied) to the earth terminal and three screws at the bottom of
antenna base.
14. Fix the antenna cable to the mast with a cable tie (local supply).
4
1. MOUNTING THE UNIT
For 50 or 100 m cable
1. Apply silicone sealant (local supply) to the threads of the pipe.
2. Unscrew three screws to remove the antenna base from the antenna unit.
3. Pass the cable assy TPA5FB0.3NJ5FBA-5DFB (supplied, 300 mm) into the shrink tube
(SCM2, supplied).
4. Attach the above cable assy to the connector at the bottom of the antenna unit (upper).
5. Shift up the shrink tube until it touches the bottom of the antenna unit (upper).
6. Heat the shrink tube, and then apply silicone rubber to the upper edge of the tube, also
wind self-bonding tape around the lower edge of the shrink tube and then wrap vinyl
tape over self-bonding tape.
Note: Between the bottom of the antenna unit (upper) and the end of the taping should be
less than 50 mm.
7. Insert the cable protector (supplied) in to the slot at the bottom of the antenna base.
8. Pass the antenna cable through the pipe and antenna base in order.
When laying the cable along side the pipe, put the cable aside to pass through the projection
in the antenna base. See [A] in the figure shown below.
Silicone
rubber
Antenna unit
(upper)
less than
50 mm
Shrink
tube
(Inner) Shrink tube
(Outer) Vinyl tape
Antenna base
Apply silicone sealant.
Antenna base, bottom view
Insert the cable
protector (wide side)
into this slot.
Select [A] or [B].
Cable protector
[A] [B]
Waterproofing
9. Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%)
10. Screw the antenna unit onto the antenna pipe by rotating the antenna unit.
11. Wind self-bonding tape (supplied) at the connection of antenna base and pipe, and then
wrap vinyl tape over self-bonding tape.
12. Fix the ground wire RW-4747 (supplied) between the ground terminal on the antenna
unit and the ground stud on the mast.
5
1. MOUNTING THE UNIT
13. Connect the antenna cable (50 or 100 m) and cable assy (attached at step 5).
14. Wrap the connector with self-bonding tape and then vinyl tape. Bind the cable end with a
cable tie (local supply).
15. Fix the cable to the mast with cable tie (local supply).
Ground terminal
Taping
(Self-bonding
tape and vinyl
tape)
Apply silicone rubber.
Ship's ground point
Pipe
Mast
See the figure in below.
Cable tie
(Weatherproofed)
Mounting
Waterproofing
6
1. MOUNTING THE UNIT
1.2 Terminal Unit
Select the following place to install the terminal unit.
• The temperature and humidity should be moderate and stable.
• For maintenance and checking purposes, leave sufficient space at the sides and rear of
the unit and leave slack in cables.
Mounting
Tabletop mounting
1. Fix the hanger on a table with four tapping screws (5x20, supplied).
282
4-φ7
240 + 0.5
80 + 0.5
29 + 3
Terminal unit, tabletop mounting
2. Screw knobs and washers to terminal unit loosely.
3. Set the terminal unit to the hanger and tighten knobs.
Flush mounting
Use local supplied pan head screws (M4x20) when the thickness of the bulkhead is from 11
to 14 mm. For bulkhead which exceeds 14 mm in thickness the length of the pan head
screws should be bulkhead thickness A +7.8±2 mm. Also the length of B should be max. 8
mm (B≤8 mm).
B
A
Bulkhead, sectional view
1. Prepare a cutout in the mounting location whose dimensions are as shown on next
page.
2. Fix the display unit by six pan head screws M4x20, inserting from the inside of the
bulkhead. Refer to the outline drawing at the end of this manual.
7
1. MOUNTING THE UNIT
38
120
80
223±1
228±0.5
M4x20
230±0.5
4.5
4-R2.25
273±1
58
Dimensions for flush mounting
Keyboard
15
1. Attach the function key label ( INM-C 12 ) to the location shown below.
Function key label (supplied)
Esc
F1
F2
!
1
F3
F4
F5
F6
F7
@
2
Q
#
3
$
4
W
%
5
E
^
6
R
&
7
T
7
Y
8
(
9
8
U
A
S
D
F
G
H
J
Z
X
C
V
B
N
Alt
2.
3.
4.
5.
Prt Sc
Scroll
Lock
~
,
{
[
P
-
:
;
L
3
<
,
>
. .
Alt
Ins
Backspace
}
]
?
/ /
Home
Pg Up
\
Pg Dn
"
'
+
Pause
Break
I
+
=
-
6
2
0
_
O
K
M
Shift
Fn
Num
Lock
)
0
5 5
1
Ctrl
F10
9
I
4
Ctrl
F9
Sys Rq
Tab
Caps
Lock
F8
F12
F11
Enter
Enter
End
Shift
Del
Attach four fasteners (small, supplied) to the bottom of the keyboard.
Attach four fasteners (large, supplied) to the small fasteners attached in step 3.
Peel the paper from four fasteners.
Fix the keyboard to the mounting place.
8
1. MOUNTING THE UNIT
1.3 Distress Alert/Received Call Unit IC-305/
Alarm Unit IC-306
ALARM
ACK
ALARM
ACK
Distress alert/received call unit IC-305
Alarm unit IC-306
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the bottom chassis to the mounting location with four tapping screws (supplied).
3. Cable can be entered from bottom or rear panel. Select suitable entrance. For rear
panel entrance, change the clamp orientation as follows.
a) Unfasten two screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten two screws removed at step a) to fix the clamp.
Unfasten these screws.
Refasten screws.
Rotate.
Cable clamp, rotating
4. Run the interconnection cable thru a cable entrance and connect it to terminal board.
Flush mounting
The optional flush mounting kit OP16-27 (Code No. 004-448-000) is required.
Name
Type
Code No.
Qty
Remarks
Fixture
16-018-4201-1 100-317-841
1
Pan head screw
M3x6
000-800-362
4
Self-tapping screw 4x16
000-162-605-10
4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied as the option kit).
3. Fasten four tapping screws (ø5, supplied as the option kit) to mount the fixture to the
mounting position.
9
1. MOUNTING THE UNIT
1.4
Printer PP-510 (option)/
EGC Printer PP-505 (option)
PP-510 (option)
Lay the printer on a table and fix it with printer fixtures 1 and 2.
Attach labels appropriately; right side of printer for the compass safety distance label and
front of printer for INMAR C label.
Printer fixture 2
INMARSAT label "C"
Printer
fixture1
200
Label for
Compass safety distance
405
Printer PP-510
PP-505 (option)
1. Fix the hanger on a table with four tapping screws.
2. Screw knobs into printer.
3. Set printer to hanger and tighten knobs.
1.5
AC/DC Power Supply Unit PR-240 (option)
Fix the unit on a table with four tapping screws.
272 + 1
100 + 1
AC/DC power supply unit, dimensions
10
1. MOUNTING THE UNIT
1.6
Junction Box IC-315
The junction box IC-315 is connected to the terminal unit by using the cable assy 16S0344
(2 m, attached to the junction box). Install the junction box within 2 m from the terminal unit.
1. Remove four screws from the unit to separate the bottom chassis from the top chassis.
2. Fix the bottom chassis to the mounting location with four tapping screws (4x16:
supplied).
3. Connect the cables appropriately referring to Chapter 2.
120 + 0.5
70 + 0.5
Junction box IC-315, dimensions
11
2.
WIRING
24 VDC
When using 50 or 100m
antenna cable.
VCTF-0.75x3C
(5 m)
Printer
PP-510
0.34 m
Ground wire
8D-FB-CV, 50 m
12D-SFA-CV, 100 m
16S0184,
3m
TP5FBAW-5DFBB,
30 m
Mini keyboard
G84-4100PPAUS
TNCP-NJ
connector
(Supplied)
DGPS
LAN cable
(10BaseT, local supply)
Remove the cover to use.
Connector
N-P-12DSFA
N-P-8DFB
(Supplied, local arrangement)
*: Local arrangement
MJ-A3SPF0018-050Z
CAUTION
Copper strap
1.2 m
Power supply
24 VDC
The terminal unit is shipped with a 15 A
fuse in its power cable. This fuse is for use
with a 12 VDC power supply.
For a 24 VDC power supply, replace the
fuse with a 7A fuse (supplied). Attach the
"7A" label to the fuse holder on the power
cable. Use of a wrong fuse can damage the
equipment.
Junction Box
IC-315
CO-SPEVV-SB-C 0.2x5p
(option)
or TTYCS-4
(Japanese
*
Industrial
Standards)
#: When connecting with the Distress Message
Controller DMC-5, set the DMC-5's function for
"SES (EGC)," in the SET UP EGC/SES menu,
referring to chapter 7 "SYSTEM SETTINGS" in the
operator's manual for DMC-5 (OME-5540).
Further, connect a jumper wire between TB5-#1
and TB5-#3 on the DMC-5.
*
* *
*
DMC-5#
Distress alert/
Received call
unit
IC-305
Wiring of FELCOM 15
12
* *
Alarm unit
IC-306
Navigator
2. WIRING
2.1
Antenna Cable Connector at the Terminal Unit
8D-FB-CV (50 m)
Outer Sheath
Armor
Dimensions in millimeters.
Inner Sheath Shield
50
30
Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
Cover with heat-shrink tubing and heat.
Remove insulator and core by 10 mm.
10
30
Twist shield end.
Slip on clamp nut, gasket and clamp as shown
left.
Clamp
Nut
Gasket
(reddish
brown)
Clamp
Aluminum Foil
Fold back shield over clamp and trim.
Trim shield here.
Cut aluminum foil at four places, 90 from one
another.
Insulator
Fold back aluminum tape foil onto shield and trim.
Trim aluminum
tape foil here.
1
Expose the insulator by 1 mm.
5
Expose the insulator by 5 mm.
Pin
Clamp Nut
Slip the pin onto the conductor. Solder them
together through the hole on the pin.
Shell
Insert the pin into the shell. Screw the clamp
nut into the shell.
(Tighten by turning the clamp nut. Do not
tighten by turning the shell.)
Solder through
the hole.
How to fabricate antenna cable 8D-FB-CV (50 m)
13
2. WIRING
12D-SFA-CV (100 m)
Outer Sheath
Armor
Dimensions in millimeters.
Shield
Inner Sheath
12
80
Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
Twist shield end.
Slip on clamp nut, gasket and clamp as shown left.
Nut
Gasket
Washer
Clamp
1.8
Expose the insulator by 1.8 mm.
Expose the core by 4.5 mm.
4.5
Pin
Slip the pin onto the conductor. Solder them
together through the hole on the pin.
Clamp Nut
Solder through
the hole.
Insert the pin into the shell. Screw the clamp
nut into the shell.
(Tighten by turning the clamp nut. Do not
tighten by turning the shell.)
How to fabricate antenna cable 12D-SFA-CV
14
2. WIRING
2.2
Distress Alert/Received Call Unit IC-305
Use the installation material CP16-02201 to connect the distress alert IC-305.
The optional CO-SPEVV-SB-C 0.2x5P cable or JIS cable (Japan Industrial
Standards) TTYCS-4 or equivalent are available to connect with the junction box
IC-305. Select the cable clamp attached depending on the diameter of cable,
and fix the armor of cable with the clamp.
Armor
Shield
Vinyl sheath
Conductor
(Twisted pair)
S =1.25 mm
=1.35 mm
2
Painting
(Sectional view)
TTYCS-4 cable, sectional view
16P0213
For CO-SPEVVSB-C 0.2x5P
1 2 3
4
5
Twist the shield.
For TTYCS-4 (JIS)
or equivalent
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Distress alert
IC-305
15 mm 40 mm 10 mm
Cut unused cables.
Wiring of distress alert IC-305
15
2. WIRING
2.3
Alarm Unit IC-306
Maximum two alarm units can be connected to the junction box IC-315 in parallel.
To distinguish the incoming indictors, set jumper wires for the second alarm unit
as below. For connection, refer to the “2.2 Distress Alert/Received Call Unit
IC-305.”
16P0213
JP2
JP1
Alarm unit IC-306
No. 1 (default setting)
No. 2
JP1
Cut
Cut
JP2
Shorten
Cut
16
2. WIRING
2.4
Junction Box IC-315
Use the junction box IC-315 to connect the distress alert/received call unit
IC-305 and other unit (max. four units) to the terminal unit.
Unfasten four screws to remove the box cover to connect cables.
Cover
Cable clamp
To terminal unit
Terminal
board
1 Vcc
2 GND
3 TD/RD-A
4 TD/RD-B
5 NC
6 TD-A(NAV)
7 TD-B(NAV)
8 RD-A(NAV)
9 RD-B(NAV)
10 GND
11 DMC OUT-H
12 DMC OUT-C
13 DMC IN-H
14 DMC IN-C
15 DMC CTR
IC-305/306
For connection, use the optional 5 pair cable CO-SPEVV-SB-C 0.2x5P, JIS cable
(Japan Industrial Standards) TTYCS-4 or equivalent. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with IC-315.
1
2
3
Core 7 mm
Sticker for
connection of
other equipment
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
4. Pull out the driver.
Note 1: Do not insert the cable deeply
to prevent pinching the cable sheath.
Note 2: Pull the cable slightly to confirm
the tightening
Junction Box IC-315
Input/output sentences
The following sentences can be input/output with the navigator connected.
Input sentences
Output sentences
GGA, GLL, VTG, WPL, RMA, RMB,
RMC, MTW, DBT, BWC, BWR, VDR,
GGA, ZDA, GLL, VTG, RMC, GSV
ZDA
17
3. INITIAL SETTINGS
3.1
Setting the IMN (INMARSAT MOBILE NO.)
After the wiring, set your IMN (Inmarsat Mobile No.) as below.
1. Turn the power on.
2. Press the function key [F8] to show the Setup menu.
File
Edit
Transmit
EGC
Reports
Logs
Options
Setup
Position
StopAlarm
Setup
1. Distress Alert Setup
2. System Setup
3. Editor Setup
4. Terminal Setup
5. EGC Setup
6. Auto Mode Setup
7. E-Mail Setup
8. Directories
9. Configuration
Setup menu
3. Press [2] key to display the System Setup menu.
Setup
System Setup
System Date & Time
IMN
MES Operation Mode
Nav Port
Active Port
Message Output Port
EGC Output Port
9.Network
Configuration
Setup
Command Window
4.
5.
6.
7.
8.
01:53 02-02-25 (YY-MM-DD)
INMARSAT-C
OFF
INT
INT
INT
System Setup menu
Confirm that the IMN is selected, and then press the [Enter] key.
The entering field appears.
Key in your IMN.
Press the [Enter] key.
Press the [Esc] key to disappear the entering field.
Press the [Enter] key.
To clear the IMN, press [I] [M] [N] in order while pressing the [Alt] key down at step 5.
18
3.2
Setting for External Equipment
The FELCOM 15 system had been set to accommodate to distress alert/received call unit
IC-305, alarm unit IC-306 and distress message controller DMC-5 at factory. If less than
three units are connected, change the setting to OFF as below.
1. Press the [F8] key to show the Setup menu.
2. Press the [2] key to show the System Setup menu.
3. Press the [↓] key to select “Command Window”, and then press [Enter] key to show the
Command Window screen.
4. Referring to the service manual for FELOM15, fill in the “Enter JOB No.:” and then press
the [Enter] key.
5. As similar to step 4, fill in the “PASSWORD:”, and then press the [Enter] key.
[Main Menu] is highlighted.
6. Press the [1] and [Enter] keys in order.
Setup
System Setup
01:53 02-02-25 (YY-MM-DD)
System Date & Time
IMN
Command Window
INMARSAT-C
MES Operation Mode
[
Main
Menu
]
OFF
Nav Port
1. Remote
Active
Port Box Setup INT
2. Internal
GPSPort
Setup INT
Message
Output
Enter
JOB Port
No.: 1
INT
EGC
Output
9.Network
Configuration
Setup
[ RemoteWindow
Box Setup ]
Command
1. DMC
ON
2. IC-305
ON
3. IC-306 No.1
ON
4. IC-306 No.2
ON
5. IC-306 No.3
ON
E: Exit
Enter No.:
Command Window screen
7. Press the number key for unit not connected, and then press the [Enter] key.
For example, press the [1] and [Enter] keys when the DMC-5 is not connected.
[ DMC ]
1. ON
2. OFF
E: Exit
Enter No.:
Setting window for DMC-5
8. Press the [2] key, and the [Enter] key.
Instead of a numeric key, press the [E] key to return to Remote Box Setup menu.
9. Repeat steps 7 to 8 for other unit not connected.
10. Press the [Esc] key several times to close the menu.
19
4. INSTALLATION OF GPS BOARD
(OPTION)
This chapter provides the procedure for the installation of the GPS board (in the terminal
unit), which provides GPS position information.
Name: GPS board
Type: OP16-47
Code No.: 000-017-110
Name
GPS board
Pan head screw
Type
16P0246
M3x8
Code No.
004-656-550
000-163-190-10
Qty
1
3
Remarks
Note: Use anti-static gloves to treat board.
1. Unfasten 18 screws, six spacers and three nuts to remove the terminal unit cover.
Torque
0.7±60.02 N·m
Torque
1.37±0.1 N·m
Nut
Rounding
side
Nut, flat washer
Cover
Spacer
6 pcs.
Pan head screw
M3x8, 18 pcs.
*
*
*
*
*
*
*
*
*
**
*
**
*
*
*
*
*
*
*
*
*
*
*
*
*: Remove
Terminal unit, cover removed
20
*
4. INSTALLATION OF GPS BOARD (OPTION)
2. Unfasten four pan head screws (M3x8) to remove the RF cover (S).
3. Fasten three pan head screws (M3x8, supplied with the kit) to attach the GPS board to
the RF cover.
4. Attach the 7P connector from the RF cover to the JI on the GPS board.
Cable
Pan head screw
M3x8, 3 pcs.
7P connector
GPS board
J1
Pan head screw
M3x8, 4 pcs.
(marked with "#")
# #
RF cover (S)
#
#
J1
RF cover
Grommet
Removing RF Cover (S)/Fixing GPS Board
5. Pass the cable from the GPS board through the hole on the RF cover, and then connect
it to J4 on the RF CON/CPU board.
RF CON/CPU board
GPS board
How to treat connectors
1. Attach the connector at right angle.
If not, connector pins may be bent.
2. After connecting connector assemblies, the load
on their cables should be as below.
Pass the cable
through this hole.
J4
RF cover
less than 2.94N (300gf)
Pass the cable
under the RF cover.
less than 9.8N (1kgf)
Fix the cable with the clamp.
less than 2.94N (300gf)
Fasten the cable at the clamp next to the J4 connector.
6. Remount the RF cover (S) using four pan head screws (M3x8) unfastened at step 2.
21
4. INSTALLATION OF GPS BOARD (OPTION)
7. Reassemble the terminal unit as below.
a) Fasten six spacers ○
a by hand tentatively.
b) Fasten eight pan head screws ○
b tightly.
a by box driver tightly.
c) Fasten six spacers ○
d) Fasten other screws and washers to complete.
b
a
b
b
b
Terminal unit, rear view
22
5. CHANGING POWER SUPPLY
SPECIFICATIONS
The AC-DC power supply PR-240 is shipped ready for connection to a 200-230 VAC ship’s
mains. If the ship’s mains is 100 VAC-115 VAC, change the tap connection and terminal
board connection as below. Attach a label supplied as accessories to the front panel
according to the ship’s mains.
Ship’s mains
Tap connection
Terminal board
Label
200-230 VAC
SEL 230 V
Below (a)
200-230 VAC 2.2-1.7 A
1φ 50/60 Hz
100-115 VAC
SEL 115 V
Below (b)
100-115 VAC 3.2-2.6 A
1φ 50/60 Hz
Remove screw
and cover.
Cover
Front panel
(a) 200-230 VAC
1
Black
2
3
Grey
Terminal board
(b) 100-115 VAC
1
Black
2
3
Grey
Relay
Coil
J4
3
2
1
SEL
115V
1
2
3
4
5
6
7
8
SEL
230V
Heat sink
Tap connection
(Pull out to disconnect.)
Front panel
Attach appropriate label.
AC FAIL:Connect to Alarm system.
Output Setting: Normal Close Set plug to 2 & 3 pins of J4 (Factory setting)
Normal Open
Set plug to 1 & 2 pins of J4
AC Power Switch
(When connecting DC input, note that the DC power is supplied
even though this switch is turned off.)
Note: The DC output load must be less than 8A.
23
INSTALLATION MATERIALS
DOCUMENT
000-147-004-1*
C52-00206-*
000-807-330-1*
J5-950010-* ワ/エイ
004-439-390-00
CP16-02302
004-439-380-00
CP16-02301
000-172-018-10
G84-4100PPAUS
004-439-400-00
FP16-00601
004-439-370-00
**
1
Q'TY
1
1
1
CP16-02302
1
CP16-02301
1
1
FP16-00600
1
SP16-01301
SP16-01301 (IC-215用)
000-043-432-00
IC-215*
DESCRIPTION/CODE №
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
NAME
DISTRESS COMMUNICATION
遭難通信要領
INSTALLATION MANUAL
装備要領書
OPERATOR'S MANUAL
取扱説明書
OPERATOR'S MANUAL
取扱説明書
BEFORE DELIVERING TO OWNER
機器引渡し前の注意
OUTLINE
1/1
000-809-352-1*
TIC-56350-* ワ/エイ
000-809-350-1*
IM*-56350-*
000-150-358-1*
OM*-56351-*
000-809-348-1*
OM*-56350-*
000-809-353-1*
C52-00201-* ワ/エイ
1
1
1
1
1
Q'TY
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN
PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
16AK-X-9851
**
**
**
DESCRIPTION/CODE №
16AK-X-9851 -6
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。
IC-215-J*/IC-215-E*
1.コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。
CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL
NOTICE FOR FUSE REPLACEMENT
ヒューズ変更のお願い
REGISTRATION FOR SERVICE
ACTIVATION
アプリケーションフォ-ム
図書
INSTALLATION MATERIALS
工事材料
工事材料
OUTLINE
INSTALLATION MATERIALS
ACCESSORIES
SPARE PARTS
UNIT
INSTALLATION MATERIALS
工事材料
工事材料
KEYBOARD
ミニキーボード
FLOPPY DISK
フロッピーディスク組品
付属品
SPARE PARTS
予備品
予備品
TERMINAL UNIT
ターミナルユニット
ユニット
NAME
PACKING LIST
A-1
0#/'
176.+0'
&1%7/'06
+056#..#6+10/#6'4+#.5
70+6
0#/'
176.+0'
(8
(8
.(
:575
%2
+%
&'5%4+26+10%1&'ͳ
36;
#-:
#-:
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
+056#..#6+10/#6'4+#.5
70+6
A-3
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%4+/210.7)
࿶⌕┵ሶ
%4+/210.7)
࿶⌕┵ሶ
5'.(6#22+0)5%4'9
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
Ꮏ੐᧚ᢱ
#.#4/70+6
⌕ାᜰ␜ེ
࡙࠾࠶࠻
#-: 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
36;
+%
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
A-2
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
%
(8
(8
.(
:575
%2
+%
&'5%4+26+10%1&'ͳ
#-: ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪈㪅㩿㪁㪈䋩䈱䋪䋪䋪䋪䈲䇮᦭䉍䊶ή䈚䈱઀᭽䈏᦭䉍䉁䈜䇯
㪘㪭㪘㪠㪣㪘㪙㪣㪜㩷㪮㪠㪫㪟㩷㪦㪩㩷㪮㪠㪫㪟㪦㪬㪫㩷㪁㪁㪁㪁㪁㩷㪬㪥㪠㪫㪅
$'(14'&'.+8'4+0)61190'4
+%ᒁ߈ᷰߒ೨ߩᵈᗧ
࿑ᦠ
%4+/210.7)
࿶⌕┵ሶ
%4+/210.7)
࿶⌕┵ሶ
5'.(6#22+0)5%4'9
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
Ꮏ੐᧚ᢱ
&+564'55#.'4670+6
ㆣ㔍⼊ႎེ
࡙࠾࠶࠻
+%
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55;
㨻㩧㩍㩏㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
ฬ‫ޓޓ‬⒓
0#/'
+%
⇛‫ޓޓ‬࿑
176.+0'
%1&'
01
62($#9&($$/
%1&'
01
&($%8/
%1&'
01
&5(#%8/
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
ㆬᛯ‫ޓޓޓޓޓޓޓޓ‬
61$'5'.'%6'&
ㆬᛯ‫ޓޓޓޓޓޓޓޓ‬
61$'5'.'%6'&
ㆬᛯ‫ޓޓޓޓޓޓޓޓ‬
61$'5'.'%6'&
↪ㅜ㧛஻⠨
4'/#4-5
#-: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#-:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
6;2'
%1&'01
A-4
5+.+%1047$$'4
㩃㩚㩆㨺㩣
)4170&9+4'
㨻㨺㩇✢
5'.($10&+0)6#2'
㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩
%#$.'2416'%6+10
/#6'4+#.
㩃㨺㩖㩨㩣଻⼔᧚
+057.#6+105.''8'
㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
%1&'01 59㨻㩣㩚㩋㨷㨺㩖㩨)
59㨻㩣㩚㩋㨷㨺㩖㩨)‫ޓ‬
%1&'01
49
%1&'01
01
%1&'01
41*5
%1&'01
㩂㩥‫ޓ‬//
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%2
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
#-: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#-:
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
6;2'
%1&'01
A-5
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
59㨻㩣㩚㩋㨷㨺㩖㩨)
052&5(#
49
%1&'01 %#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
%1#:+#.%100'%614
#&#2614
㩄㩒㩂㩊
60%0
5+.+%1047$$'4
59㨻㩣㩚㩋㨷㨺㩖㩨)
%1&'01
62#($10,($#&($
%1&'01
60%20,
%1&'01 ↪ㅜ㧛஻⠨
4'/#4-5
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#-:
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#-:
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
052&5(#%(
%1&'01
01
%1&'01
ᢙ㊂
36;
#-: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
%1&'01
62#($10,($#&($
%1&'01
60%20,
%1&'01 41*5
%1&'01
㩂㩥‫ޓ‬//
ဳฬ㧛ⷙᩰ
&'5%4+26+105
59㨻㩣㩚㩋㨷㨺㩖㩨)‫ޓ‬
㩃㩚㩆㨺㩣
)4170&9+4'
㨻㨺㩇✢
%100'%614
㩄㩒㩂㩊
0
5'.($10&+0)6#2'
㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩
%#$.'2416'%6+10
/#6'4+#.
㩃㨺㩖㩨㩣଻⼔᧚
+057.#6+105.''8'
㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/
⇛‫ޓޓ‬࿑
176.+0'
59㨻㩣㩚㩋㨷㨺㩖㩨)‫ޓ‬
ฬ‫ޓޓ‬⒓
0#/'
%1&'01
⇟ภ
01
%1&'01
49
%1&'01
02&($%(
%1&'01
01
%1&'01
41*5
%1&'01
㩂㩥‫ޓ‬//
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%2
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
%1#:+#.%100'%614
#&#2614
㩄㩒㩂㩊
60%0
5+.+%1047$$'4
㩃㩚㩆㨺㩣
)4170&9+4'
㨻㨺㩇✢
%100'%614
㩄㩒㩂㩊
0
5'.($10&+0)6#2'
㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩
%#$.'2416'%6+10
/#6'4+#.
㩃㨺㩖㩨㩣଻⼔᧚
5*4+0-67$+0)
㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/
⇛‫ޓޓ‬࿑
176.+0'
6;2'
%1&'01
A-7
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
ฬ‫ޓޓ‬⒓
0#/'
+056#..#6+10/#6'4+#.5
⇟ภ
01
+056#..#6+10/#6'4+#.5
#-: Ꮏ੐᧚ᢱ⴫
%2
6;2'
Ꮏ੐᧚ᢱ⴫
%1&'01
A-6
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
.#$'.
㩔㩢㩙㨺㩂
24+06'4(+:674'
㩖㩩㩢㩧㩊ขઃ᧼
⚵ຠ
24+06'4(+:674'
㩖㩩㩢㩧㩊ขઃ᧼
⚵ຠ
5'.(6#22+0)5%4'9
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨‫ޓ‬㩆㨷
219'4%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
.#$'.
+0/#4
㩔㩢㩙㨺㩂
+0/#4
ฬ‫ޓޓ‬⒓
0#/'
%1&'
01
,'
%1&'
01
‫ޓ‬41*5
%1&'
01
%2
%1&'
01
%2
%1&'
01
:575
%1&'
01
5
%1&'
01
41*5
㩊㨺㩚㩏㩣㩟㩐㨹㩎↪‫(ޓ‬14
6'4/+0#.70+6
%1/2#555#('
&+56#0%'
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#%:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
5'.(6#22+0)5%4'9
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
%#$.'%.#/2
㩃㨺㩖㩨㩣᛼߃
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%2
%1&'
01
:575
%1&'
01
41*5
6;2'
%1&'01
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
#-: A-9
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#-:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
+056#..#6+10/#6'4+#.5
↪ㅜ㧛஻⠨
4'/#4-5
+056#..#6+10/#6'4+#.5
ᢙ㊂
36;
#%: Ꮏ੐᧚ᢱ⴫
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%2
6;2'
Ꮏ੐᧚ᢱ⴫
⇛‫ޓޓ‬࿑
176.+0'
%1&'01
A-8
+056#..#6+10/#6'4+#.5
70+6
176.+0'
%2
24
36;
A-10
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
##:
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
##: &'5%4+26+10%1&'ͳ
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ
Ꮏ੐᧚ᢱ
219'45722.;70+6
#%&%㔚Ḯ
࡙࠾࠶࠻
0#/'
24%'/5#
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
⇟ภ
01
⇛‫ޓޓ‬࿑
176.+0'
%1&'01
((#
%1&'01
%1&'01
%1&'01 ‫ޓ‬41*5
%1&'01
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
12
6;2'
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
#-:
6196;2'5#0&%1&'5/#;$'.+56'&6*'$1661/241&%6/#;$'5*+22'&+02.#%'1(6*'612241&7%637#.+6;
6*'5#/'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢߤߜࠄ߆߇౉ߞߡ޿߹ߔ‫ޔ߅ߥޓޕ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
↪ㅜ㧛஻⠨
4'/#4-5
#-: 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
5'#.
((#㩆㨺㩣
(.122;&+5-41/
(&41/
0#/'2.#6'
#.%
ဳᑼ㌏᧼
#.%
.#$'.
㩔㩢㩙㨺㩂
#.%
%*+0#41*55'#.
ਛ࿖41*5㩙㨺㩂
ฬ‫ޓޓ‬⒓
0#/'
/1&+(+%#6+10-+6
ᡷㅧ㩁㨹㩎
%1&'01
A-11
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ/,
(75').#5567$'6;2'
㩕㨷㨺㩇㩨
5'.(6#22+0)5%4'9
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨‫ޓ‬㩆㨷
%122'4564#2
㨻㨺㩇᧼
(75'.#$'.
㩕㨷㨺㩇㩨㩔㩢㩙㨺㩂
ฬ‫ޓޓ‬⒓
0#/'
+%
⇛‫ޓޓ‬࿑
176.+0'
%1&'
01
/,#52(<%
%1&'
01
()$18#2$(
%1&'
01
:575
%1&'
01
41*5
%1&'
01
41*5
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%2
6;2'
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
#-: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#-:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
%1&'01
A-12
.#$'.
%5&
㩔㩢㩙㨺㩂
%5&
.#$'.
㩔㩢㩙㨺㩂
.#$'.
㩔㩢㩙㨺㩂
*11-.112(#56'0'4
㩖㨱㩇㩏㨺
*11-.112(#56'0'4
㩖㨱㩇㩏㨺
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
%1&'01
41*5
%1&'01
41*5
%1&'01
%1&'01
41*5
%1&'01
41*5
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
/+0+-';$1#4&
$6%%25)
22#75
%2
$6%%25↪
$6%%25↪
)22#75↪
↪ㅜ㧛஻⠨
4'/#4-5
#-: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
#-:
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
6;2'
%1&'01
A-13
(75'
㩕㨷㨺㩇㩨
(75'
㩕㨷㨺㩇㩨
()$18#
2$(
()$18
#2$(
2'4
8'5
#-: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ
⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(
6*'722'4241&7%637#.+6;+56*'5#/'
5'652'4
8'55'.
$1:012
4'/#4-5%1&'01
#-:
52#4'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕
&9)01
2'4
5'6
914-+0)
37#06+6;
75'
52
6;2'
&9)01
14
6;2'01
(74701'.'%64+%%1.6&
176.+0'
52#4'2#465.+56(14
0#/'1(
2#46
/(450#/'
+6'/
01
5*+201
%1&'01
A-14
D-1
Dec.19'05
18/Jun/09 R.Esumi
D-2
18/Jun/09 R.Esumi
D-3
8/Jul/09 R.Esumi
D-4
Y. Hatai
D-5
D-6
July 14'03
Y. Hatai
D-7
D-8
Dec. 20, '02
D-9
Mar.03'05
5/Feb/09 R.Esumi
D-10
D-11
Oct.15'07 R.Esumi
D-12
D-13
Y. Hatai
,WN4'UWOK
D-14
1
2
3
4
5
6
S-1
アンテナユニット
ANTENNA UNIT
IC-115
ケーブル/コネクタは選択
SELECT CABLE & CONNECTOR
TPA5FB0.3NJ5
FBA-5DFB,0.3m
TNCP-NJ
RW-4747
0.3m
12D-SFA-CV,100m,φ20: N-P-12DSFA
8D-FB-CV,50m,φ14.3: N-P-8DFB
A
ターミナルユニット
TERMINAL UNIT
IC-215
*7
ANT
TP5FBAW-5DFBB,30m,φ10.7
P
P
DGPS
BNC PLUG
*1
COAX. CABLE(50Ω)
DGPSデコーダー
DGPS DECODER
2B02 16P0208A
キーボード
KEYBOARD
船内LAN (HUB)
パソコンなど
LAN(HUB) OR PC, ETC.
1.6m
P
B
P
24VDC
RH12BPG-3S
VCTF-0.75x3C,5m,φ7 アカ RED
1 +24V
(16S0084)
2 0V
クロ BLK
3 GND
シロ WHT
プリンタ
PRINTER
PP-510
1
*2
36
*4
C
MJ-A3SPF0018-050ZC,5m,φ11
12-24 VDC
100-115/
*1
200-230 VAC DPYC-2.5
1φ,50/60Hz
*1
24 VDC DPYC-4
PE
*1
IV-2sq.
保護アース
1
2
3
4
5
6
7
8
LAN
E_TD_P
E_TD-N
E_RD_P
NC
NC
E_RD_N
NC
NC
*3
17JE-23250
-02(D8C)
16S0184,3m,φ8
24 VDC
KEYBOARD
KDAT
NC
GND
+5V
KCLK
NC
RJ-45
STP CABLE(CAT5) *1
PC: CROSS CABLE
HUB: STRAIGHT CABLE
*3
57-3036
1
2
3
4
5
6
DTE
PRINTER
1
RXD
TXD
25
GND
*4
2B03 16P0209
FUSE
*3
15A(12V)
12-24VDC
MJ-A3SPF
7A(24V)
1 DC(+)
シロ WHT
2 DC(-)
クロ BLK
3 GND
2B10
AC
IN
+ DC
- IN
E
AC/DC
24VDC +
電源ユニット OUT AC/DC POWER
SUPPLY UNIT
PR-240
*2
JUNCTION
Vcc(ALM)
GND
TD/RD-A
TD/RD-B
NC
TD-A
TD-B
RD-A
RD-B
GND
DMC_OUT-H
DMC_OUT-C
DMC_CHECK
DMC_IN-C
DMC_CTRL
16P0214
銅板
COPPER STRAP
W=30,1.2m
接続箱
JUNCTION BOX
IC-315
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
*3
Dsub15P
2m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
*1
TTYCS-4
P
P
TTYCS-1(*1) OR
CO-0.2x2P(*2)
GND
P
NOTE
*1. SHIPYARD SUPPLY.
*2. OPTION.
*3. FITTED AT FACTORY.
*4. GROUND THRU CONNECTOR CLAMP.
*5. TB BOARD (16P0116) REQUIRED.
*6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*7. DO NOT SHORTEN ANTENNA CABLE.
TTYCS-4(*1) OR
CO-0.2x5P(*2)
RXD
TXD
DTR
GND
DSR
RTS
CTS
NC
RXD
TXD
0V
EGCプリンタ
EGC PRINTER
PP-505 (+) 1
*2
7
NC
1
2
3
4
5
RXD
TXD
NC
NC
0V *2
(-)
P
P
*1
TTYCS-1
3
4
P
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.2)
*2 *6
1
2
3
4
5
6
P
P
INMARSAT No.1/2
1 TR-A
2 TR-B アラームユニット
ALARM UNIT
3 FG
IC-350 *2
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.3)
*2 *6
1
2
3
4
5
6
合計 :最大200m
TOTAL: UP TO 200m
I/F BOX
OP16-14
1
2
3
4
5
6
7
*2
FM14-7P
FM14-7P
CO-0.2x5P,MAX.100m
1
2
P
3
P
4
5
6
7
*4
*4
25/Jun/09
CHECKED
25/Jun/09
SCALE
T.YAMASAKI
RXD-H
TXD-H
FG
TXD-C
RXD-C
+9V
NC
EGCプリンタ
EGC PRINTER
PP-505 *2 *5
(+)
(-)
1
2
08S0157,3m
T.TAKENO
TITLE
C5635-C01- R
FELCOM 15
インマルサットC船舶地球局
相互結線図
8/Jul/09 R.Esumi
MASS
24VDC
GND
08S0087
名称
kg
DWG No.
24VDC
GND
08S0087
FM14-5P
APPROVED
08S0157,3m
2
*4
DRAWN
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
SSAS_OUT-H
NC
SSAS_CHECK
SSAS_IN-C
SSAS_CTRL
GND
IC-315
最大3台まで接続可能。
MAX.3 SETS AVAILABLE.
パソコン
PC
NC
*2
FM14-7P
CO-0.2x2P,MAX.15m
1
2
3
*4
D
選択
SELECT
17JE-23090
-02(D8C)
1
2
3
4
5
6
7
8
9
*4
注記
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)コネクタクランプでアースに落とす。
*5)TB基板(16P0116)が必要。
*6)終端のIC-307はジャンパー設定を変更する。
*7)アンテナケーブルは切断して使用しないこと。
IC-350を接続するとき(IC-305との共用不可)
CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
*4
DTE
RXD
TXD
1
2
3
4
5
6
P
2
3
4
5
6
7
8
9
*4
遭難警報器 IC-305
DISTRESS ALERT/
RECEIVED CALL UNIT
16P0213A
1 VCC
2 GND
3 TD/RD-A
4 TD/RD-B
5 FG
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.1) *2 *6
TTYCS-4(*1) OR
CO-0.2x5P(*2)
17JE-23090
17JE-13090
*2
-02(D8C) 17JE-573-10,5m,φ8 -02(D8C)
CO-0.2x5P,MAX.15m
1
1
2
3
4
5
6
7
8
9
航法装置
NAV EQUIPMENT
アラームユニットIC-306
ALARM UNIT
16P0213B
1 VCC
2 GND
3 TD/RD-A
4 TD/RD-B
5 FG
NAME
INMARSAT-C MES
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.