INMARSAT-C MOBILE EARTH STATION FELCOM 15 Installation Manual TABLE OF CONTENTS EQUIPMENT LISTS......................................................................................................................ii SYSTEM CONFIGURATION .......................................................................................................iii 1. MOUNTING THE UNIT..........................................................................................................1 1.1 Antenna Unit.................................................................................................................1 1.2 Terminal Unit ................................................................................................................7 1.3 Distress Alert/Received Call Unit IC-305/Alarm Unit IC-306 ........................................9 1.4 Printer PP-510 (option)/EGC Printer PP-505 (option) ................................................10 1.5 AC/DC Power Supply Unit PR-240 (option) ...............................................................10 1.6 Junction Box IC-315 ...................................................................................................11 2. WIRING ...............................................................................................................................12 2.1 Antenna Cable Connector at the Terminal Unit..........................................................13 2.2 Distress Alert/Received Call Unit IC-305....................................................................13 2.3 Alarm Unit IC-306 .......................................................................................................16 2.4 Junction Box IC-315 ...................................................................................................17 3. INITIAL SETTING................................................................................................................18 3.1 Setting the IMN (INMARSAT MOBILE NO.)...............................................................18 3.2 Setting for External Equipment...................................................................................19 4. INSTALLATION OF GPS BOARD (OPTION).....................................................................20 5. CHANGING POWER SUPPLY SPECIFICATIONS ............................................................23 PACKING LISTS....................................................................................................................... A-1 OUTLINE DRAWINGS.............................................................................................................. D-1 INTERCONNECTION DIAGRAM ............................................................................................. S-1 www.furuno.co.jp All brand and product names are trademarks, registered trademarks or service marks of their respective holders. The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 All rights reserved. Printed in Japan A : DEC . 2002 F : JUL . 10, 2009 Pub. No. IME-56350-F (DAMI ) FELCOM15 *00080935115* *00080935115* * 0 0 0 8 0 9 3 5 1 1 5 * SAFETY INSTRUCTIONS CAUTION WARNING Do not open the equipment unless totally familiar with electrical circuits and service manual. Confirm that the power supply voltage is compatible with the voltage rating of the equipment. Connection to the wrong power supply can cause fire or equipment damage. The voltage rating appears on the label at the rear of the terminal unit. ELECTRICAL Only qualified personnel should work inside the SHOCK equipment. HAZARD Do not approach the radome closer than 60 cm when it is transmitting. Use the correct fuse. Use 10 A fuse (defalt setting) for 12 VDC power supply, or replace the fuse to 5 A (supplied as spare parts) with 24 VDC. Microwave radiation can cause severe injury or illness. Radiation level: 2 10 W/m at 60 cm Use of wrong fuse can result in damage to the equipment. Turn off the power at the mains switchboard before beginning the installation. Post a sign near the switch to indicate it should not be turned on while the equipment is being installed. Keep the following compass safe distances. Standard Steering Fire, electrical shock or serious injury can result if the power is left on or is applied while the eqiuipment is being installed. Antenna Unit IC-115 0.30 m 0.30 m Terminal Unit IC-215 0.70 m 0.40 m Printer PP-510 1.00 m 0.80 m Junction Box IC-315 1.00 m 0.70 m Received Call Unit IC-305 0.50 m 0.30 m Alarm Unit IC-306 0.50 m 0.30 m EGC Printer PP-505 2.05 m 1.40 m 0.90 m 0.60 m 0.30 m 0.30 m Distress Alert/ AC/DC Power Supply Unit PR-240 Mini keyboard Attach securely protection earth to the ship's body. The protection earth is required to the power supply to prevent electrical shock. i EQUIPMENT LISTS Standard Supply Name Antenna Unit Terminal Unit Distress Alert/ Received Call Unit Alarm Unit Junction Box Installation Materials Code No. Qty IC-115 IC-215 Type - 1 1 IC-305 - 1 IC-306 IC-315 CP16-02101 CP16-02111 CP16-02121 004-439-060 004-439-070 004-439-080 1 1 CP16-02300 000-043-433 1 set 004-438-890 000-159-523-11 000-117-599 1 set CP16-02201 TP5FBAW-5DFBB 8D-FB-CV 12D-SFA-CV Accessories FP16-00600 Spare Parts SP16-01301 1 set 1 000-138-866 1 set 000-043-434 004-439-370 1 set Remarks w/CP16-02501* For 30 m cable, antenna unit* For 50 m cable, antenna unit* For 100 m cable, antenna unit* CP16-02301 (for IC-215)*, CP16-02302 (for keyboard)* For IC-305/306 30 m antenna cable 50 m antenna cable 100 m antenna cable Mini keyboard (G84-4100PPAUS), FD (FP16-00601) Fuse* Optional Supply Name FD-ROM GPS Board GPS Board Kit RF Cover (GPS) EGC Printer Printer AC/DC Power Supply Unit Type 16-5-0164 OP16-47 OP16-48 OP16-49 PP-505 PP-510 PR-240 Code No. 004-438-920 001-017-110 000-011-766 000-011-767 000-560-452 000-103-868 000-103-869 000-132-829 000-132-828 Qty 1 set 1 set 1 set 1 1 1 1 5-pair cable CO-SPEVV-SB-C 0.2x5P SSAS Modification Kit** OP16-33 000-043-492 1 SSAS Alert Unit** IC-307 000-043-473 1 OP16-27 004-448-000 1 Flush Mounting Kit 1 Remarks w/CP16-01200* w/CP24-00151* For junction box, 10m For junction box, 20m For junction box, 30m For junction box, 40m For junction box, 50m IC-307 (2units), FD-ROM (for RFCON CPU, for TERM CPU) w/CP16-03101, FP16-00901 For distress alert/received call unit, alarm unit For SSAS alert unit OP16-28 004-448-010 1 ALC (FFA) Modification Kit* OP16-26 004-439-840 1 Russian Language Kit OP16-43 004-449-590 1 For IC-215 PC Terminal Software OP16-45 004-449-600 1 Russian Language Antenna Mounting Kit CP16-03701 004-555-000 1 set Antenna Bracket CP16-03702 001-016-260 1 See page D-14. Antenna Mounting Pipe CP16-03703 001-014-510 1 *: See packing lists at the back of this manual. **: The SSAS modification kit is required for the SSAS. For installation of three IC-307s, additional SSAS alert unit is necessary. ii SYSTEM CONFIGURATION ANTENNA UNIT IC-115 DGPS POWER SUPPLY 100-115/200-230 VAC 1φ, 50/60 Hz AC-DC Power Supply PR-240 TERMINAL UNIT IC-215 POWER SUPPLY 12/24 VDC GPS Board OP16-47 EGC Printer** PP-505 Personal Computer (PC/AT compatible) 24 VDC Printer Shipboard LAN (Ethernet) Printer** PP-510 * For 12 VDC power supply, DC-DC converter is required to use PP-510. 24 VDC Mini Keyboard Distress Alert/ Received Call Unit IC-305 Distress Message Controller DMC-5 JUNCTION BOX IC-315 OR SSAS Alert Unit* SSAS Alert Unit* IC-307 IC-307 (Max. 3 units) Navigator *: At least two SSAS Alert Units are required. **: Mandatory for EGC operation as required by IMO RES. A.664(16). CATEGORY OF UNITS Unit Category Terminal Unit Protected from weather Antenna Unit Exposed to weather Other Units Protected from weather Alarm Unit IC-306 iii : Standard Supply : Option : Local Supply This page is intentionally left blank. iv 1. MOUNTING THE UNIT NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 1.1 Antenna Unit Mounting Location • Mount the omnidirectional antenna unit high atop a mast clear of stays and the turning diameter of a radar antenna. The ideal mounting location would be where no obstacle appears in the fore and aft directions down to -5º and down to -15º in the port and starboard directions. This concept is illustrated in the figure below. Shadow sector of the antenna mast, whip antenna, etc. should be within 2 degrees at one meter from the antenna unit. ANTENNA UNIT 5 5 15 15 Antenna unit mounting location • If both Inmarsat-B/F and Inmarsat-C ship earth stations are installed, separate the Inmarsat-B/F antenna at least 8 m from the Inmarsat-C antenna. • Separate the antenna unit from an S-band radar as follows: Install above this line INSTALLTION ZONE 2m 1.5 m 15 PROHIBITED ZONE 2m 5m S-band radar HORIZONTAL LINE S-band radar and installation area 1 1. MOUNTING THE UNIT • The allowable vibration level as specified by Inmarsat is as shown in the table below. Allowable vibration level Frequency Level 2 to 10 Hz 2.54 mm Peak Amplitude 10 to 100 Hz 9.8 m/s² Peak Acceleration • Avoid the location near funnels and stacks; smoke and soot on the radome can lower signal level. • Separate the antenna unit 5 m from HF, VHF or 27 MHz antenna. Mounting Thirty, 50 or 100 m antenna cable is available. Thirty meters cable has connectors on both sides, and one connector for 50/100 m cable. Do not shorten these cables to prevent interference. To mount the antenna unit, an exclusive pipe is necessary. Note: To mount the antenna unit with the optional antenna mounting kit (Type: CP16-03701, Code No.: 004-555-000), see page D-13. 20 1x14 UNS 35-S 12-S 25-S Welding 25 .4 Antenna mast Mounting pipe and antenna mast 2 6 50 , Ground stud Mounting pipe , 100 Earth wire (340 mm) 200 12-S Locally prepare an antenna mast with a ground stud (M6 stainless steel bolt welded to antenna mast) and mounting pipe with threads and plate (See the outline drawing of the mounting plate shown below.) Weld the mounting pipe to the antenna mast. The distance between the stud and the earth terminal on the antenna unit should be within 340 mm, which also is the length of the supplied earth wire. 1. MOUNTING THE UNIT For 15 or 30 m cable 1. 2. 3. 4. 5. 6. 7. 8. 9. Apply silicone sealant (local supply) to the threads of the pipe. Unscrew three screws to remove the antenna base from the antenna unit. Pass the antenna cable through the pipe, antenna base in order. Insert the cable protector (supplied) into the slot at the bottom of antenna base. Screw the antenna base onto the antenna pipe by rotating the antenna base. Pass the antenna cable into the shrink tube (SCM2, supplied). Attach the antenna cable to the connector at the bottom of the antenna unit (upper). Shift the shrink tube until it touches the bottom of the antenna unit (upper). Heat the above shrink tube, and then apply silicone rubber around the upper edge of the tube. Also wind self-bonding tape around the lower edge of the shrink tube and then wrap vinyl tape over self-bonding tape. Note: Between the bottom of the antenna unit (upper) and the end of the taping should be less than 50 mm. Antenna unit (upper) Antenna base Apply silicone sealant. Antenna base, bottom view Insert the cable protector (wide side) into this slot. Cable protector Silicone rubber less than 50 mm Shrink tube (Inner) Shrink tube (Outer) Vinyl tape Antenna unit, passing the cable through the pipe 3 1. MOUNTING THE UNIT 10. Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%) 11. Wrap self-bonding tape around the connection of antenna base and pipe, and then wind vinyl tape over self-bonding tape. These tapes should be winded closely. 12. Fix the earth wire RW-4747 (supplied) between the ground terminal on the antenna unit and the ship’s ground point. Ground terminal Apply silicone rubber. Taping (self-bonding tape and vinyl tape) Ship's ground point Cable tie (weatherproofed) Mounting 13. Apply silicone rubber (supplied) to the earth terminal and three screws at the bottom of antenna base. 14. Fix the antenna cable to the mast with a cable tie (local supply). 4 1. MOUNTING THE UNIT For 50 or 100 m cable 1. Apply silicone sealant (local supply) to the threads of the pipe. 2. Unscrew three screws to remove the antenna base from the antenna unit. 3. Pass the cable assy TPA5FB0.3NJ5FBA-5DFB (supplied, 300 mm) into the shrink tube (SCM2, supplied). 4. Attach the above cable assy to the connector at the bottom of the antenna unit (upper). 5. Shift up the shrink tube until it touches the bottom of the antenna unit (upper). 6. Heat the shrink tube, and then apply silicone rubber to the upper edge of the tube, also wind self-bonding tape around the lower edge of the shrink tube and then wrap vinyl tape over self-bonding tape. Note: Between the bottom of the antenna unit (upper) and the end of the taping should be less than 50 mm. 7. Insert the cable protector (supplied) in to the slot at the bottom of the antenna base. 8. Pass the antenna cable through the pipe and antenna base in order. When laying the cable along side the pipe, put the cable aside to pass through the projection in the antenna base. See [A] in the figure shown below. Silicone rubber Antenna unit (upper) less than 50 mm Shrink tube (Inner) Shrink tube (Outer) Vinyl tape Antenna base Apply silicone sealant. Antenna base, bottom view Insert the cable protector (wide side) into this slot. Select [A] or [B]. Cable protector [A] [B] Waterproofing 9. Remount the antenna unit (upper) on the antenna base. (Torque: 2.6 N·m ± 10%) 10. Screw the antenna unit onto the antenna pipe by rotating the antenna unit. 11. Wind self-bonding tape (supplied) at the connection of antenna base and pipe, and then wrap vinyl tape over self-bonding tape. 12. Fix the ground wire RW-4747 (supplied) between the ground terminal on the antenna unit and the ground stud on the mast. 5 1. MOUNTING THE UNIT 13. Connect the antenna cable (50 or 100 m) and cable assy (attached at step 5). 14. Wrap the connector with self-bonding tape and then vinyl tape. Bind the cable end with a cable tie (local supply). 15. Fix the cable to the mast with cable tie (local supply). Ground terminal Taping (Self-bonding tape and vinyl tape) Apply silicone rubber. Ship's ground point Pipe Mast See the figure in below. Cable tie (Weatherproofed) Mounting Waterproofing 6 1. MOUNTING THE UNIT 1.2 Terminal Unit Select the following place to install the terminal unit. • The temperature and humidity should be moderate and stable. • For maintenance and checking purposes, leave sufficient space at the sides and rear of the unit and leave slack in cables. Mounting Tabletop mounting 1. Fix the hanger on a table with four tapping screws (5x20, supplied). 282 4-φ7 240 + 0.5 80 + 0.5 29 + 3 Terminal unit, tabletop mounting 2. Screw knobs and washers to terminal unit loosely. 3. Set the terminal unit to the hanger and tighten knobs. Flush mounting Use local supplied pan head screws (M4x20) when the thickness of the bulkhead is from 11 to 14 mm. For bulkhead which exceeds 14 mm in thickness the length of the pan head screws should be bulkhead thickness A +7.8±2 mm. Also the length of B should be max. 8 mm (B≤8 mm). B A Bulkhead, sectional view 1. Prepare a cutout in the mounting location whose dimensions are as shown on next page. 2. Fix the display unit by six pan head screws M4x20, inserting from the inside of the bulkhead. Refer to the outline drawing at the end of this manual. 7 1. MOUNTING THE UNIT 38 120 80 223±1 228±0.5 M4x20 230±0.5 4.5 4-R2.25 273±1 58 Dimensions for flush mounting Keyboard 15 1. Attach the function key label ( INM-C 12 ) to the location shown below. Function key label (supplied) Esc F1 F2 ! 1 F3 F4 F5 F6 F7 @ 2 Q # 3 $ 4 W % 5 E ^ 6 R & 7 T 7 Y 8 ( 9 8 U A S D F G H J Z X C V B N Alt 2. 3. 4. 5. Prt Sc Scroll Lock ~ , { [ P - : ; L 3 < , > . . Alt Ins Backspace } ] ? / / Home Pg Up \ Pg Dn " ' + Pause Break I + = - 6 2 0 _ O K M Shift Fn Num Lock ) 0 5 5 1 Ctrl F10 9 I 4 Ctrl F9 Sys Rq Tab Caps Lock F8 F12 F11 Enter Enter End Shift Del Attach four fasteners (small, supplied) to the bottom of the keyboard. Attach four fasteners (large, supplied) to the small fasteners attached in step 3. Peel the paper from four fasteners. Fix the keyboard to the mounting place. 8 1. MOUNTING THE UNIT 1.3 Distress Alert/Received Call Unit IC-305/ Alarm Unit IC-306 ALARM ACK ALARM ACK Distress alert/received call unit IC-305 Alarm unit IC-306 Bulkhead mounting 1. Remove four screws from the unit to separate the bottom chassis from the top cover. 2. Fix the bottom chassis to the mounting location with four tapping screws (supplied). 3. Cable can be entered from bottom or rear panel. Select suitable entrance. For rear panel entrance, change the clamp orientation as follows. a) Unfasten two screws to remove the cable clamp. b) Turn the clamp 90 degrees. c) Refasten two screws removed at step a) to fix the clamp. Unfasten these screws. Refasten screws. Rotate. Cable clamp, rotating 4. Run the interconnection cable thru a cable entrance and connect it to terminal board. Flush mounting The optional flush mounting kit OP16-27 (Code No. 004-448-000) is required. Name Type Code No. Qty Remarks Fixture 16-018-4201-1 100-317-841 1 Pan head screw M3x6 000-800-362 4 Self-tapping screw 4x16 000-162-605-10 4 1. Cut out the mounting position referring to the outline drawings at the back of this manual. 2. Fix the unit to the fixture with four pan head screws (supplied as the option kit). 3. Fasten four tapping screws (ø5, supplied as the option kit) to mount the fixture to the mounting position. 9 1. MOUNTING THE UNIT 1.4 Printer PP-510 (option)/ EGC Printer PP-505 (option) PP-510 (option) Lay the printer on a table and fix it with printer fixtures 1 and 2. Attach labels appropriately; right side of printer for the compass safety distance label and front of printer for INMAR C label. Printer fixture 2 INMARSAT label "C" Printer fixture1 200 Label for Compass safety distance 405 Printer PP-510 PP-505 (option) 1. Fix the hanger on a table with four tapping screws. 2. Screw knobs into printer. 3. Set printer to hanger and tighten knobs. 1.5 AC/DC Power Supply Unit PR-240 (option) Fix the unit on a table with four tapping screws. 272 + 1 100 + 1 AC/DC power supply unit, dimensions 10 1. MOUNTING THE UNIT 1.6 Junction Box IC-315 The junction box IC-315 is connected to the terminal unit by using the cable assy 16S0344 (2 m, attached to the junction box). Install the junction box within 2 m from the terminal unit. 1. Remove four screws from the unit to separate the bottom chassis from the top chassis. 2. Fix the bottom chassis to the mounting location with four tapping screws (4x16: supplied). 3. Connect the cables appropriately referring to Chapter 2. 120 + 0.5 70 + 0.5 Junction box IC-315, dimensions 11 2. WIRING 24 VDC When using 50 or 100m antenna cable. VCTF-0.75x3C (5 m) Printer PP-510 0.34 m Ground wire 8D-FB-CV, 50 m 12D-SFA-CV, 100 m 16S0184, 3m TP5FBAW-5DFBB, 30 m Mini keyboard G84-4100PPAUS TNCP-NJ connector (Supplied) DGPS LAN cable (10BaseT, local supply) Remove the cover to use. Connector N-P-12DSFA N-P-8DFB (Supplied, local arrangement) *: Local arrangement MJ-A3SPF0018-050Z CAUTION Copper strap 1.2 m Power supply 24 VDC The terminal unit is shipped with a 15 A fuse in its power cable. This fuse is for use with a 12 VDC power supply. For a 24 VDC power supply, replace the fuse with a 7A fuse (supplied). Attach the "7A" label to the fuse holder on the power cable. Use of a wrong fuse can damage the equipment. Junction Box IC-315 CO-SPEVV-SB-C 0.2x5p (option) or TTYCS-4 (Japanese * Industrial Standards) #: When connecting with the Distress Message Controller DMC-5, set the DMC-5's function for "SES (EGC)," in the SET UP EGC/SES menu, referring to chapter 7 "SYSTEM SETTINGS" in the operator's manual for DMC-5 (OME-5540). Further, connect a jumper wire between TB5-#1 and TB5-#3 on the DMC-5. * * * * DMC-5# Distress alert/ Received call unit IC-305 Wiring of FELCOM 15 12 * * Alarm unit IC-306 Navigator 2. WIRING 2.1 Antenna Cable Connector at the Terminal Unit 8D-FB-CV (50 m) Outer Sheath Armor Dimensions in millimeters. Inner Sheath Shield 50 30 Remove outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left. Cover with heat-shrink tubing and heat. Remove insulator and core by 10 mm. 10 30 Twist shield end. Slip on clamp nut, gasket and clamp as shown left. Clamp Nut Gasket (reddish brown) Clamp Aluminum Foil Fold back shield over clamp and trim. Trim shield here. Cut aluminum foil at four places, 90 from one another. Insulator Fold back aluminum tape foil onto shield and trim. Trim aluminum tape foil here. 1 Expose the insulator by 1 mm. 5 Expose the insulator by 5 mm. Pin Clamp Nut Slip the pin onto the conductor. Solder them together through the hole on the pin. Shell Insert the pin into the shell. Screw the clamp nut into the shell. (Tighten by turning the clamp nut. Do not tighten by turning the shell.) Solder through the hole. How to fabricate antenna cable 8D-FB-CV (50 m) 13 2. WIRING 12D-SFA-CV (100 m) Outer Sheath Armor Dimensions in millimeters. Shield Inner Sheath 12 80 Remove outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left. Twist shield end. Slip on clamp nut, gasket and clamp as shown left. Nut Gasket Washer Clamp 1.8 Expose the insulator by 1.8 mm. Expose the core by 4.5 mm. 4.5 Pin Slip the pin onto the conductor. Solder them together through the hole on the pin. Clamp Nut Solder through the hole. Insert the pin into the shell. Screw the clamp nut into the shell. (Tighten by turning the clamp nut. Do not tighten by turning the shell.) How to fabricate antenna cable 12D-SFA-CV 14 2. WIRING 2.2 Distress Alert/Received Call Unit IC-305 Use the installation material CP16-02201 to connect the distress alert IC-305. The optional CO-SPEVV-SB-C 0.2x5P cable or JIS cable (Japan Industrial Standards) TTYCS-4 or equivalent are available to connect with the junction box IC-305. Select the cable clamp attached depending on the diameter of cable, and fix the armor of cable with the clamp. Armor Shield Vinyl sheath Conductor (Twisted pair) S =1.25 mm =1.35 mm 2 Painting (Sectional view) TTYCS-4 cable, sectional view 16P0213 For CO-SPEVVSB-C 0.2x5P 1 2 3 4 5 Twist the shield. For TTYCS-4 (JIS) or equivalent CO-SPEVV-SB-C 0.2X5P or TTYCS-4 Distress alert IC-305 15 mm 40 mm 10 mm Cut unused cables. Wiring of distress alert IC-305 15 2. WIRING 2.3 Alarm Unit IC-306 Maximum two alarm units can be connected to the junction box IC-315 in parallel. To distinguish the incoming indictors, set jumper wires for the second alarm unit as below. For connection, refer to the “2.2 Distress Alert/Received Call Unit IC-305.” 16P0213 JP2 JP1 Alarm unit IC-306 No. 1 (default setting) No. 2 JP1 Cut Cut JP2 Shorten Cut 16 2. WIRING 2.4 Junction Box IC-315 Use the junction box IC-315 to connect the distress alert/received call unit IC-305 and other unit (max. four units) to the terminal unit. Unfasten four screws to remove the box cover to connect cables. Cover Cable clamp To terminal unit Terminal board 1 Vcc 2 GND 3 TD/RD-A 4 TD/RD-B 5 NC 6 TD-A(NAV) 7 TD-B(NAV) 8 RD-A(NAV) 9 RD-B(NAV) 10 GND 11 DMC OUT-H 12 DMC OUT-C 13 DMC IN-H 14 DMC IN-C 15 DMC CTR IC-305/306 For connection, use the optional 5 pair cable CO-SPEVV-SB-C 0.2x5P, JIS cable (Japan Industrial Standards) TTYCS-4 or equivalent. When using the CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with IC-315. 1 2 3 Core 7 mm Sticker for connection of other equipment Procedure 1. Insert driver from direction 1 . 2. Tilt slightly toward 2 . 3. Insert cable core to 3 . 4. Pull out the driver. Note 1: Do not insert the cable deeply to prevent pinching the cable sheath. Note 2: Pull the cable slightly to confirm the tightening Junction Box IC-315 Input/output sentences The following sentences can be input/output with the navigator connected. Input sentences Output sentences GGA, GLL, VTG, WPL, RMA, RMB, RMC, MTW, DBT, BWC, BWR, VDR, GGA, ZDA, GLL, VTG, RMC, GSV ZDA 17 3. INITIAL SETTINGS 3.1 Setting the IMN (INMARSAT MOBILE NO.) After the wiring, set your IMN (Inmarsat Mobile No.) as below. 1. Turn the power on. 2. Press the function key [F8] to show the Setup menu. File Edit Transmit EGC Reports Logs Options Setup Position StopAlarm Setup 1. Distress Alert Setup 2. System Setup 3. Editor Setup 4. Terminal Setup 5. EGC Setup 6. Auto Mode Setup 7. E-Mail Setup 8. Directories 9. Configuration Setup menu 3. Press [2] key to display the System Setup menu. Setup System Setup System Date & Time IMN MES Operation Mode Nav Port Active Port Message Output Port EGC Output Port 9.Network Configuration Setup Command Window 4. 5. 6. 7. 8. 01:53 02-02-25 (YY-MM-DD) INMARSAT-C OFF INT INT INT System Setup menu Confirm that the IMN is selected, and then press the [Enter] key. The entering field appears. Key in your IMN. Press the [Enter] key. Press the [Esc] key to disappear the entering field. Press the [Enter] key. To clear the IMN, press [I] [M] [N] in order while pressing the [Alt] key down at step 5. 18 3.2 Setting for External Equipment The FELCOM 15 system had been set to accommodate to distress alert/received call unit IC-305, alarm unit IC-306 and distress message controller DMC-5 at factory. If less than three units are connected, change the setting to OFF as below. 1. Press the [F8] key to show the Setup menu. 2. Press the [2] key to show the System Setup menu. 3. Press the [↓] key to select “Command Window”, and then press [Enter] key to show the Command Window screen. 4. Referring to the service manual for FELOM15, fill in the “Enter JOB No.:” and then press the [Enter] key. 5. As similar to step 4, fill in the “PASSWORD:”, and then press the [Enter] key. [Main Menu] is highlighted. 6. Press the [1] and [Enter] keys in order. Setup System Setup 01:53 02-02-25 (YY-MM-DD) System Date & Time IMN Command Window INMARSAT-C MES Operation Mode [ Main Menu ] OFF Nav Port 1. Remote Active Port Box Setup INT 2. Internal GPSPort Setup INT Message Output Enter JOB Port No.: 1 INT EGC Output 9.Network Configuration Setup [ RemoteWindow Box Setup ] Command 1. DMC ON 2. IC-305 ON 3. IC-306 No.1 ON 4. IC-306 No.2 ON 5. IC-306 No.3 ON E: Exit Enter No.: Command Window screen 7. Press the number key for unit not connected, and then press the [Enter] key. For example, press the [1] and [Enter] keys when the DMC-5 is not connected. [ DMC ] 1. ON 2. OFF E: Exit Enter No.: Setting window for DMC-5 8. Press the [2] key, and the [Enter] key. Instead of a numeric key, press the [E] key to return to Remote Box Setup menu. 9. Repeat steps 7 to 8 for other unit not connected. 10. Press the [Esc] key several times to close the menu. 19 4. INSTALLATION OF GPS BOARD (OPTION) This chapter provides the procedure for the installation of the GPS board (in the terminal unit), which provides GPS position information. Name: GPS board Type: OP16-47 Code No.: 000-017-110 Name GPS board Pan head screw Type 16P0246 M3x8 Code No. 004-656-550 000-163-190-10 Qty 1 3 Remarks Note: Use anti-static gloves to treat board. 1. Unfasten 18 screws, six spacers and three nuts to remove the terminal unit cover. Torque 0.7±60.02 N·m Torque 1.37±0.1 N·m Nut Rounding side Nut, flat washer Cover Spacer 6 pcs. Pan head screw M3x8, 18 pcs. * * * * * * * * * ** * ** * * * * * * * * * * * * *: Remove Terminal unit, cover removed 20 * 4. INSTALLATION OF GPS BOARD (OPTION) 2. Unfasten four pan head screws (M3x8) to remove the RF cover (S). 3. Fasten three pan head screws (M3x8, supplied with the kit) to attach the GPS board to the RF cover. 4. Attach the 7P connector from the RF cover to the JI on the GPS board. Cable Pan head screw M3x8, 3 pcs. 7P connector GPS board J1 Pan head screw M3x8, 4 pcs. (marked with "#") # # RF cover (S) # # J1 RF cover Grommet Removing RF Cover (S)/Fixing GPS Board 5. Pass the cable from the GPS board through the hole on the RF cover, and then connect it to J4 on the RF CON/CPU board. RF CON/CPU board GPS board How to treat connectors 1. Attach the connector at right angle. If not, connector pins may be bent. 2. After connecting connector assemblies, the load on their cables should be as below. Pass the cable through this hole. J4 RF cover less than 2.94N (300gf) Pass the cable under the RF cover. less than 9.8N (1kgf) Fix the cable with the clamp. less than 2.94N (300gf) Fasten the cable at the clamp next to the J4 connector. 6. Remount the RF cover (S) using four pan head screws (M3x8) unfastened at step 2. 21 4. INSTALLATION OF GPS BOARD (OPTION) 7. Reassemble the terminal unit as below. a) Fasten six spacers ○ a by hand tentatively. b) Fasten eight pan head screws ○ b tightly. a by box driver tightly. c) Fasten six spacers ○ d) Fasten other screws and washers to complete. b a b b b Terminal unit, rear view 22 5. CHANGING POWER SUPPLY SPECIFICATIONS The AC-DC power supply PR-240 is shipped ready for connection to a 200-230 VAC ship’s mains. If the ship’s mains is 100 VAC-115 VAC, change the tap connection and terminal board connection as below. Attach a label supplied as accessories to the front panel according to the ship’s mains. Ship’s mains Tap connection Terminal board Label 200-230 VAC SEL 230 V Below (a) 200-230 VAC 2.2-1.7 A 1φ 50/60 Hz 100-115 VAC SEL 115 V Below (b) 100-115 VAC 3.2-2.6 A 1φ 50/60 Hz Remove screw and cover. Cover Front panel (a) 200-230 VAC 1 Black 2 3 Grey Terminal board (b) 100-115 VAC 1 Black 2 3 Grey Relay Coil J4 3 2 1 SEL 115V 1 2 3 4 5 6 7 8 SEL 230V Heat sink Tap connection (Pull out to disconnect.) Front panel Attach appropriate label. AC FAIL:Connect to Alarm system. Output Setting: Normal Close Set plug to 2 & 3 pins of J4 (Factory setting) Normal Open Set plug to 1 & 2 pins of J4 AC Power Switch (When connecting DC input, note that the DC power is supplied even though this switch is turned off.) Note: The DC output load must be less than 8A. 23 INSTALLATION MATERIALS DOCUMENT 000-147-004-1* C52-00206-* 000-807-330-1* J5-950010-* ワ/エイ 004-439-390-00 CP16-02302 004-439-380-00 CP16-02301 000-172-018-10 G84-4100PPAUS 004-439-400-00 FP16-00601 004-439-370-00 ** 1 Q'TY 1 1 1 CP16-02302 1 CP16-02301 1 1 FP16-00600 1 SP16-01301 SP16-01301 (IC-215用) 000-043-432-00 IC-215* DESCRIPTION/CODE № (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) NAME DISTRESS COMMUNICATION 遭難通信要領 INSTALLATION MANUAL 装備要領書 OPERATOR'S MANUAL 取扱説明書 OPERATOR'S MANUAL 取扱説明書 BEFORE DELIVERING TO OWNER 機器引渡し前の注意 OUTLINE 1/1 000-809-352-1* TIC-56350-* ワ/エイ 000-809-350-1* IM*-56350-* 000-150-358-1* OM*-56351-* 000-809-348-1* OM*-56350-* 000-809-353-1* C52-00201-* ワ/エイ 1 1 1 1 1 Q'TY TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. 16AK-X-9851 ** ** ** DESCRIPTION/CODE № 16AK-X-9851 -6 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 IC-215-J*/IC-215-E* 1.コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL NOTICE FOR FUSE REPLACEMENT ヒューズ変更のお願い REGISTRATION FOR SERVICE ACTIVATION アプリケーションフォ-ム 図書 INSTALLATION MATERIALS 工事材料 工事材料 OUTLINE INSTALLATION MATERIALS ACCESSORIES SPARE PARTS UNIT INSTALLATION MATERIALS 工事材料 工事材料 KEYBOARD ミニキーボード FLOPPY DISK フロッピーディスク組品 付属品 SPARE PARTS 予備品 予備品 TERMINAL UNIT ターミナルユニット ユニット NAME PACKING LIST A-1 0#/' 176.+0' &1%7/'06 +056#..#6+10/#6'4+#.5 70+6 0#/' 176.+0' (8 (8 .( :575 %2 +% &'5%4+26+10%1&'ͳ 36; #-: #-: 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 +056#..#6+10/#6'4+#.5 70+6 A-3 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 %4+/210.7) ⌕┵ሶ %4+/210.7) ⌕┵ሶ 5'.(6#22+0)5%4'9 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷 Ꮏ᧚ᢱ #.#4/70+6 ⌕ାᜰ␜ེ ࡙࠾࠶࠻ #-: 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 36; +% 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 A-2 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 % (8 (8 .( :575 %2 +% &'5%4+26+10%1&'ͳ #-: ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 㪈㪅㩿㪁㪈䋩䈱䋪䋪䋪䋪䈲䇮䉍䊶ή䈚䈱᭽䈏䉍䉁䈜䇯 㪘㪭㪘㪠㪣㪘㪙㪣㪜㩷㪮㪠㪫㪟㩷㪦㪩㩷㪮㪠㪫㪟㪦㪬㪫㩷㪁㪁㪁㪁㪁㩷㪬㪥㪠㪫㪅 $'(14'&'.+8'4+0)61190'4 +%ᒁ߈ᷰߒ೨ߩᵈᗧ ࿑ᦠ %4+/210.7) ⌕┵ሶ %4+/210.7) ⌕┵ሶ 5'.(6#22+0)5%4'9 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷 Ꮏ᧚ᢱ &+564'55#.'4670+6 ㆣ㔍⼊ႎེ ࡙࠾࠶࠻ +% 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ %#$.'#55; 㨻㩧㩍㩏㩃㨺㩖㩨㩣⚵ຠ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ ฬޓޓ⒓ 0#/' +% ⇛ޓޓ࿑ 176.+0' %1&' 01 62($#9&($$/ %1&' 01 &($%8/ %1&' 01 &5(#%8/ ဳฬ㧛ⷙᩰ &'5%4+26+105 ᢙ㊂ 36; ㆬᛯޓޓޓޓޓޓޓޓ 61$'5'.'%6'& ㆬᛯޓޓޓޓޓޓޓޓ 61$'5'.'%6'& ㆬᛯޓޓޓޓޓޓޓޓ 61$'5'.'%6'& ↪ㅜ㧛⠨ 4'/#4-5 #-: 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #-: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ ࠎޕ 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/' ⇟ภ 01 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ 6;2' %1&'01 A-4 5+.+%1047$$'4 㩃㩚㩆㨺㩣 )4170&9+4' 㨻㨺㩇✢ 5'.($10&+0)6#2' 㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩 %#$.'2416'%6+10 /#6'4+#. 㩃㨺㩖㩨㩣⼔᧚ +057.#6+105.''8' 㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/ ฬޓޓ⒓ 0#/' ⇛ޓޓ࿑ 176.+0' %1&'01 59㨻㩣㩚㩋㨷㨺㩖㩨) 59㨻㩣㩚㩋㨷㨺㩖㩨)ޓ %1&'01 49 %1&'01 01 %1&'01 41*5 %1&'01 㩂㩥ޓ// ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 #-: 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #-: 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ⇟ภ 01 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ 6;2' %1&'01 A-5 ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 59㨻㩣㩚㩋㨷㨺㩖㩨) 052&5(# 49 %1&'01 %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ %1#:+#.%100'%614 #&#2614 㩄㩒㩂㩊 60%0 5+.+%1047$$'4 59㨻㩣㩚㩋㨷㨺㩖㩨) %1&'01 62#($10,($#&($ %1&'01 60%20, %1&'01 ↪ㅜ㧛⠨ 4'/#4-5 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #-: 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #-: 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' 052&5(#%( %1&'01 01 %1&'01 ᢙ㊂ 36; #-: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ %1&'01 62#($10,($#&($ %1&'01 60%20, %1&'01 41*5 %1&'01 㩂㩥ޓ// ဳฬ㧛ⷙᩰ &'5%4+26+105 59㨻㩣㩚㩋㨷㨺㩖㩨)ޓ 㩃㩚㩆㨺㩣 )4170&9+4' 㨻㨺㩇✢ %100'%614 㩄㩒㩂㩊 0 5'.($10&+0)6#2' 㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩 %#$.'2416'%6+10 /#6'4+#. 㩃㨺㩖㩨㩣⼔᧚ +057.#6+105.''8' 㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/ ⇛ޓޓ࿑ 176.+0' 59㨻㩣㩚㩋㨷㨺㩖㩨)ޓ ฬޓޓ⒓ 0#/' %1&'01 ⇟ภ 01 %1&'01 49 %1&'01 02&($%( %1&'01 01 %1&'01 41*5 %1&'01 㩂㩥ޓ// ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ %1#:+#.%100'%614 #&#2614 㩄㩒㩂㩊 60%0 5+.+%1047$$'4 㩃㩚㩆㨺㩣 )4170&9+4' 㨻㨺㩇✢ %100'%614 㩄㩒㩂㩊 0 5'.($10&+0)6#2' 㩖㩨㩋㩣㩄㩨㩛㩍㨺㩖㩩 %#$.'2416'%6+10 /#6'4+#. 㩃㨺㩖㩨㩣⼔᧚ 5*4+0-67$+0) 㨼㩡㨹㩂㩇㩇㩢㨺㩖㩨5%/ ⇛ޓޓ࿑ 176.+0' 6;2' %1&'01 A-7 ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ฬޓޓ⒓ 0#/' +056#..#6+10/#6'4+#.5 ⇟ภ 01 +056#..#6+10/#6'4+#.5 #-: Ꮏ᧚ᢱ %2 6;2' Ꮏ᧚ᢱ %1&'01 A-6 %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ .#$'. 㩔㩢㩙㨺㩂 24+06'4(+:674' 㩖㩩㩢㩧㩊ขઃ᧼ ⚵ຠ 24+06'4(+:674' 㩖㩩㩢㩧㩊ขઃ᧼ ⚵ຠ 5'.(6#22+0)5%4'9 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷 219'4%#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ .#$'. +0/#4 㩔㩢㩙㨺㩂 +0/#4 ฬޓޓ⒓ 0#/' %1&' 01 ,' %1&' 01 ޓ41*5 %1&' 01 %2 %1&' 01 %2 %1&' 01 :575 %1&' 01 5 %1&' 01 41*5 㩊㨺㩚㩏㩣㩟㩐㨹㩎↪(ޓ14 6'4/+0#.70+6 %1/2#555#(' &+56#0%' 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #%: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ ࠎޕ 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/' ⇟ภ 01 5'.(6#22+0)5%4'9 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷 %#$.'%.#/2 㩃㨺㩖㩨㩣߃ ฬޓޓ⒓ 0#/' ⇛ޓޓ࿑ 176.+0' ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 %1&' 01 :575 %1&' 01 41*5 6;2' %1&'01 ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 #-: A-9 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #-: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ ࠎޕ 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/' ⇟ภ 01 +056#..#6+10/#6'4+#.5 ↪ㅜ㧛⠨ 4'/#4-5 +056#..#6+10/#6'4+#.5 ᢙ㊂ 36; #%: Ꮏ᧚ᢱ ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 6;2' Ꮏ᧚ᢱ ⇛ޓޓ࿑ 176.+0' %1&'01 A-8 +056#..#6+10/#6'4+#.5 70+6 176.+0' %2 24 36; A-10 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 ##: 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ##: &'5%4+26+10%1&'ͳ 䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ䍘䍎䍢䍼䉕䈚䉁䈜䇯 㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ Ꮏ᧚ᢱ 219'45722.;70+6 #%&%㔚Ḯ ࡙࠾࠶࠻ 0#/' 24%'/5# 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 ⇟ภ 01 ⇛ޓޓ࿑ 176.+0' %1&'01 ((# %1&'01 %1&'01 %1&'01 ޓ41*5 %1&'01 ဳฬ㧛ⷙᩰ &'5%4+26+105 ᢙ㊂ 36; 12 6;2' 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 #-: 6196;2'5#0&%1&'5/#;$'.+56'&6*'$1661/241&%6/#;$'5*+22'&+02.#%'1(6*'612241&7%637#.+6; 6*'5#/' ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢߤߜࠄ߆߇ߞߡ߹ߔޔ߅ߥޓޕຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ↪ㅜ㧛⠨ 4'/#4-5 #-: 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 5'#. ((#㩆㨺㩣 (.122;&+5-41/ (&41/ 0#/'2.#6' #.% ဳᑼ㌏᧼ #.% .#$'. 㩔㩢㩙㨺㩂 #.% %*+0#41*55'#. ਛ࿖41*5㩙㨺㩂 ฬޓޓ⒓ 0#/' /1&+(+%#6+10-+6 ᡷㅧ㩁㨹㩎 %1&'01 A-11 %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ/, (75').#5567$'6;2' 㩕㨷㨺㩇㩨 5'.(6#22+0)5%4'9 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷 %122'4564#2 㨻㨺㩇᧼ (75'.#$'. 㩕㨷㨺㩇㩨㩔㩢㩙㨺㩂 ฬޓޓ⒓ 0#/' +% ⇛ޓޓ࿑ 176.+0' %1&' 01 /,#52(<% %1&' 01 ()$18#2$( %1&' 01 :575 %1&' 01 41*5 %1&' 01 41*5 ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 6;2' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 #-: 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #-: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ ࠎޕ 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/' ⇟ภ 01 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ %1&'01 A-12 .#$'. %5& 㩔㩢㩙㨺㩂 %5& .#$'. 㩔㩢㩙㨺㩂 .#$'. 㩔㩢㩙㨺㩂 *11-.112(#56'0'4 㩖㨱㩇㩏㨺 *11-.112(#56'0'4 㩖㨱㩇㩏㨺 ฬޓޓ⒓ 0#/' ⇛ޓޓ࿑ 176.+0' %1&'01 41*5 %1&'01 41*5 %1&'01 %1&'01 41*5 %1&'01 41*5 ဳฬ㧛ⷙᩰ &'5%4+26+105 ᢙ㊂ 36; /+0+-';$1#4& $6%%25) 22#75 %2 $6%%25↪ $6%%25↪ )22#75↪ ↪ㅜ㧛⠨ 4'/#4-5 #-: 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 #-: 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ⇟ภ 01 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ 6;2' %1&'01 A-13 (75' 㩕㨷㨺㩇㩨 (75' 㩕㨷㨺㩇㩨 ()$18# 2$( ()$18 #2$( 2'4 8'5 #-: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ ⾰ߪᄌࠊࠅ߹ߖࠎޕ 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1( 6*'722'4241&7%637#.+6;+56*'5#/' 5'652'4 8'55'. $1:012 4'/#4-5%1&'01 #-: 52#4' 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(ޓ144'('4'0%'10.;㧕 &9)01 2'4 5'6 914-+0) 37#06+6; 75' 52 6;2' &9)01 14 6;2'01 (74701'.'%64+%%1.6& 176.+0' 52#4'2#465.+56(14 0#/'1( 2#46 /(450#/' +6'/ 01 5*+201 %1&'01 A-14 D-1 Dec.19'05 18/Jun/09 R.Esumi D-2 18/Jun/09 R.Esumi D-3 8/Jul/09 R.Esumi D-4 Y. Hatai D-5 D-6 July 14'03 Y. Hatai D-7 D-8 Dec. 20, '02 D-9 Mar.03'05 5/Feb/09 R.Esumi D-10 D-11 Oct.15'07 R.Esumi D-12 D-13 Y. Hatai ,WN4'UWOK D-14 1 2 3 4 5 6 S-1 アンテナユニット ANTENNA UNIT IC-115 ケーブル/コネクタは選択 SELECT CABLE & CONNECTOR TPA5FB0.3NJ5 FBA-5DFB,0.3m TNCP-NJ RW-4747 0.3m 12D-SFA-CV,100m,φ20: N-P-12DSFA 8D-FB-CV,50m,φ14.3: N-P-8DFB A ターミナルユニット TERMINAL UNIT IC-215 *7 ANT TP5FBAW-5DFBB,30m,φ10.7 P P DGPS BNC PLUG *1 COAX. CABLE(50Ω) DGPSデコーダー DGPS DECODER 2B02 16P0208A キーボード KEYBOARD 船内LAN (HUB) パソコンなど LAN(HUB) OR PC, ETC. 1.6m P B P 24VDC RH12BPG-3S VCTF-0.75x3C,5m,φ7 アカ RED 1 +24V (16S0084) 2 0V クロ BLK 3 GND シロ WHT プリンタ PRINTER PP-510 1 *2 36 *4 C MJ-A3SPF0018-050ZC,5m,φ11 12-24 VDC 100-115/ *1 200-230 VAC DPYC-2.5 1φ,50/60Hz *1 24 VDC DPYC-4 PE *1 IV-2sq. 保護アース 1 2 3 4 5 6 7 8 LAN E_TD_P E_TD-N E_RD_P NC NC E_RD_N NC NC *3 17JE-23250 -02(D8C) 16S0184,3m,φ8 24 VDC KEYBOARD KDAT NC GND +5V KCLK NC RJ-45 STP CABLE(CAT5) *1 PC: CROSS CABLE HUB: STRAIGHT CABLE *3 57-3036 1 2 3 4 5 6 DTE PRINTER 1 RXD TXD 25 GND *4 2B03 16P0209 FUSE *3 15A(12V) 12-24VDC MJ-A3SPF 7A(24V) 1 DC(+) シロ WHT 2 DC(-) クロ BLK 3 GND 2B10 AC IN + DC - IN E AC/DC 24VDC + 電源ユニット OUT AC/DC POWER SUPPLY UNIT PR-240 *2 JUNCTION Vcc(ALM) GND TD/RD-A TD/RD-B NC TD-A TD-B RD-A RD-B GND DMC_OUT-H DMC_OUT-C DMC_CHECK DMC_IN-C DMC_CTRL 16P0214 銅板 COPPER STRAP W=30,1.2m 接続箱 JUNCTION BOX IC-315 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 *3 Dsub15P 2m 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 *1 TTYCS-4 P P TTYCS-1(*1) OR CO-0.2x2P(*2) GND P NOTE *1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. *4. GROUND THRU CONNECTOR CLAMP. *5. TB BOARD (16P0116) REQUIRED. *6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. *7. DO NOT SHORTEN ANTENNA CABLE. TTYCS-4(*1) OR CO-0.2x5P(*2) RXD TXD DTR GND DSR RTS CTS NC RXD TXD 0V EGCプリンタ EGC PRINTER PP-505 (+) 1 *2 7 NC 1 2 3 4 5 RXD TXD NC NC 0V *2 (-) P P *1 TTYCS-1 3 4 P 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.2) *2 *6 1 2 3 4 5 6 P P INMARSAT No.1/2 1 TR-A 2 TR-B アラームユニット ALARM UNIT 3 FG IC-350 *2 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.3) *2 *6 1 2 3 4 5 6 合計 :最大200m TOTAL: UP TO 200m I/F BOX OP16-14 1 2 3 4 5 6 7 *2 FM14-7P FM14-7P CO-0.2x5P,MAX.100m 1 2 P 3 P 4 5 6 7 *4 *4 25/Jun/09 CHECKED 25/Jun/09 SCALE T.YAMASAKI RXD-H TXD-H FG TXD-C RXD-C +9V NC EGCプリンタ EGC PRINTER PP-505 *2 *5 (+) (-) 1 2 08S0157,3m T.TAKENO TITLE C5635-C01- R FELCOM 15 インマルサットC船舶地球局 相互結線図 8/Jul/09 R.Esumi MASS 24VDC GND 08S0087 名称 kg DWG No. 24VDC GND 08S0087 FM14-5P APPROVED 08S0157,3m 2 *4 DRAWN CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 SSAS_OUT-H NC SSAS_CHECK SSAS_IN-C SSAS_CTRL GND IC-315 最大3台まで接続可能。 MAX.3 SETS AVAILABLE. パソコン PC NC *2 FM14-7P CO-0.2x2P,MAX.15m 1 2 3 *4 D 選択 SELECT 17JE-23090 -02(D8C) 1 2 3 4 5 6 7 8 9 *4 注記 *1)造船所手配。 *2)オプション。 *3)工場にて取付済み。 *4)コネクタクランプでアースに落とす。 *5)TB基板(16P0116)が必要。 *6)終端のIC-307はジャンパー設定を変更する。 *7)アンテナケーブルは切断して使用しないこと。 IC-350を接続するとき(IC-305との共用不可) CONNECTION FOR IC-350 (DO NOT USE W/ IC-305) *4 DTE RXD TXD 1 2 3 4 5 6 P 2 3 4 5 6 7 8 9 *4 遭難警報器 IC-305 DISTRESS ALERT/ RECEIVED CALL UNIT 16P0213A 1 VCC 2 GND 3 TD/RD-A 4 TD/RD-B 5 FG 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.1) *2 *6 TTYCS-4(*1) OR CO-0.2x5P(*2) 17JE-23090 17JE-13090 *2 -02(D8C) 17JE-573-10,5m,φ8 -02(D8C) CO-0.2x5P,MAX.15m 1 1 2 3 4 5 6 7 8 9 航法装置 NAV EQUIPMENT アラームユニットIC-306 ALARM UNIT 16P0213B 1 VCC 2 GND 3 TD/RD-A 4 TD/RD-B 5 FG NAME INMARSAT-C MES INTERCONNECTION DIAGRAM FURUNO ELECTRIC CO., LTD.