CSEN10E - rkc instrument inc.

Temperature Sensors
• Thermocouples
• Resistance Temperature Detectors
R
Precautions for Temperature Sensor
Insertion length
To measure the temperature accurately, the temperature sensor should be thermally balanced against the measuring object. If the actual
insertion length of the protection tube is short, the temperature sensor will be thermally affected from the surrounding area and cause an error.
The required insertion length will differ depending on the measuring object, protection tube, etc. Install the temperature sensor so that the
insertion length will be longer than the values shown in Table 1.
Table 1 : Insertion of thermocouple (Melt protection tube)
· Reference value
Measuring object
Insertion length
Liquid
More than 5 times of protection tube diameter
More than 10 times of protection tube diameter
Gas
Insertion length
Protection tube
diameter
· Resistance temperature detector should be inserted more deeply.
(Approx 2 times of thermocouple)
WIRING
Check polarity when wiring for the following. Wrong polarity causes measurement error.
· Connect temperature sensors to element wires, compensation cables, connectors or terminal blocks.
Use appropriate compensation cables to joint between terminal boxes and instruments when thermocouple is used.
Use copper wire cables when resistance temperature detector used.
When connecting the sensor to a terminal block or a connector, make sure all connections are properly made. If screws are not tightened firmly
enough, it may cause a loose contact. A burr on the cable may cause short circuit.
Consider heat resistance of cable. Contacting cable to heat source or putting it closer causes insulation failure, short-circuit or cable break.
Double-element type thermocouple
When thermocouple is double-element type, measurement point is bonded together regardless of grounded junction or ungrounded
junction. No need to divide into plus polar and minus polar in each element. Specify when ordering if measurement points need to be
bonded individually.
HANDLING
Connect to specified terminals of sensor inputs when connecting temperature sensors to instruments. Connecting to power supply cause burn, fire or
explosion.
Do not install sensors:
Near a high-voltage power supply.
At places where high-voltage could be applied to them due to electric leakage or other causes.
Avoid quick heating and cooling. It causes failure or damage due to heating shock.
(Especially pay attention to it in case of using Ceramic Thermocouple Protection Tube .)
Do not touch temperature sensors till those temperature return to ambient temperature when temperature sensors are used at high or low
temperature. It causes burn injury or cold injury.
Confirm that temperature sensors work well after installment.
MgO sheathed temperature sensor
Do not bend repeatedly though it is able to bend in the range of 5 times radius of sensor’s diameter. It causes failure or damage.
· Bending work can be specified in the range of three-times radius when ordering.
Do not bend at the point within 100mm from the tip of measuring points since resistance element is mounted at the tip.
If the ordered protection tube is long, it may be shipped coiled. To uncoil the tube, carefully restore it by uncoiling it into the reverse direction of
coiling. (Don’t pull the tube with force while it is still in coil form)
Temperature sensor with sleeve
Don’t bend the cable sharply near the sleeve fixed with resin. Do not use the sensor where the temperature of the sleeve parts exceeds its high limit of
operating temperature. It causes disconnection, connection failure, or short-circuit.
Sheath thermocouples can be ordered with a minimum protection tube length of 50mm.
However, with a short protection tube, the temperature on the sleeve may be affected by the heat source and need longer time to get stabilized. Temperature
error may be also larger. It is recommended to order the protection tube with a longer length considering the operating temperature.
Temperature sensor with lead wire
Do not forcibly pull the lead wire, it may cause connection failure or short-circuit. When installing or removing sensors using stainless steel shield
wire, handle with care to prevent a break of the thin shield wire. Do not bend the lead wire or slide spring excessively or repeatedly.
Protect your hands with gloves to avoid hurting by shielded cable.
Fluorine resin coated temperature sensor
Fluorine resin coated temperature is sexcels in chemical resistance. However some chemicals penetrate into the internal of the sensor.
Use it within the range of the specifications.
Temperature sensor with porcelain protection pipe
Porcelain protection pipe is easy to be broken. Do not apply an excessive force to the part of protection pipe.
INSPECTION IN USING
Inspect regularly as follows.
· Inspect damaged condition of protection pipe.
· Remove extraneous matter such as soot, dust or sludge.
· Tighten screw at junction part.
· Remove water drops or dew condensation
· Inspect insulation resistance. (except grounded junction sensor)
· Other usage environment.
· Inspect accuracy regularly.
DISPOSAL
Dispose of sensors in compliance with the law, regulation, and any other applicable rules at the place where the sensor is used.
NOTICE
RKC is not responsible for any damage or injury that is caused as a result of using this sensor, sensor failure or indirect damage.
RKC is not responsible for any damage and/or injury resulting from the use of sensors made by imitating this instrument.
Every effort has been made to ensure accuracy of all information contained herein. RKC makes no warranty expressed or implied, with respect to the
accuracy of the information. The information in this manual is subject to change without prior notice.
1
CONTENTS
1) Precautions for temperature Sensor
1
Screwed tip thermocouples T-230
2) Contents
2
Fixing screw type thermocouples for surface temperature
measurement T-240
Ring type thermocouples for surface temperature
measurement T-250
Thermocouples for resin temperature T-260
3) Temperature sensor list
3-4
4) Installation example
5
5) Mounting brackets
6
6) Lead wire termination • Terminal head •
Measuring junction • Tip processing
7-8
7) Thermocouple connectors
9-10
8) Thermocouples
• General purpose thermocouples
11-36
11-19
Spring loaded type thermocouples T-100,T-110
12
Sleeve type thermocouplesT-101,T-111
13
No sleeve type thermocouples T-102
14
Terminal head type thermocouples T-30,T-35
15
Exposed terminal head type thermocouples T-80,T-85
16
Metal connector type thermocouples T-90
17
Noble Metal type thermocouples T-30,T-35
18
Noble Metal type thermocouplesT-80,T-85
19
• Sheathed type thermocouples
20-24
Sleeve type thermocouples T-101S,T-111S
20
Terminal head type thermocouples T-30S,T-35S
21
Thermocouple connector type thermocouples T-70S,T-75S
22
Exposed terminal head type thermocouples T-80S,T-85S
23
Metal connector type thermocouples T-90S
24
• Nicrobell sheathed thermocouples
25-27
Sleeve type thermocouples T-101N,T-111N
26
Terminal head type thermocouples T-30N,T-35N
27
Thermocouples for resin temperature
(Zero-heat-flow method) T-270Z
Adhesive and exposed tip type
temperature sensors ST-50,ST-51
Temperature sensors for
extremely small surface ST-55,ST-56
Thermocouple type non-contact
temperature sensors ST-100
Thermocouple type non-contact
temperature sensors ST-100K
Rotationary roll surface temperature measuring
sensors JBS-3898
34
34
35
36
36
37-38
39-41
42
43
44
45-54
9) Resitance temperature detectors
• General purpose resistance temperature detectors 45-49
Sleeve type resistance temperature detectors
R-101,R-111
No sleeve type resistance temperature detectors
R-102
Terminal head type resistance temperature detectors
R-30,R-35
Metal connector type resistance temperature detectors
R-90
• Sheathed type resistance temperature detectors
Sleeve type resistance temperature detectors
R-101,R-111S
46
47
48
49
50-54
50
Terminal head type resistance temperature detectors
51
R-30S,R-35S
Metal connector type resistance temperature detectors
52
R-90S
Sanitary type sheathed resistance temperature detectors
53-54
R-31S/R-36S/R-31RS/R-36RS
10) PFA (Fluororesin) coated temperature sensors
• Thermocouples for various applications
Bayonet type (With spring loaded)
thermocouples T-200,T-210
Bayonet type (Sleeve type)
thermocouples T-201,T-211
Bayonet type (Sleeve type)
sheathed thermocouples T-201S,T-211S
Bayonet type sheathed thermocouples
for high temperature (Variable insertion length type)
T-202SH,T-212SH
Bayonet type thermocouples
(Variable insertion length type) T-220,T-221
28-36
29
30
31
Thermocpuple/Resistance temperature detectors
FT-100,FR-100
11) Reference information
Thermocouples
Resistance temperature detectors
Protection tubes
Lead wires
Compensation lead wires
Responsiveness of sensors
32
12) Temperature sensor specification check sheet
33
13) Calibration service for temperature sensors
55-56
57-59
57
58
59
59
59
59
60
61-62
2
Temperature Sensor List
General Purpose Temperature Sensors
Measuring Range
Type
-200 0 200 400 600 800 1000 1200 1400 1600
T Type
200°C(250°C)
K,J Type
Thermocouples
300°C(400°C)
Measuring range differ to protection tube diameter, etc.
Appearance
Features
T-100/T-110
T-110 is protection tube 90° bend type.
Standard type.
The diameter of protection tube is either
5 or 6.
Reference
page
12
T-101/T-111
T Type
T-111 is protection tube 90° bend type.
250°C(300°C)
T-102
J Type
450°C(550°C)
T-30/35
Thermocouples
E Type
500°C(550°C)
Standard type.
A variety of kinds are available.
13 to 17
Temperature sensor which is suitable
for high temperature measurement.
Platinum is used for element.
18 to 19
Thin protection pipe is available.
Faster responsiveness.
Excellent Vibration and shock
resistance.
20 to 24
High stability, and excellent heat and
environmental resistance.
Capable of high temperature
measurement.
Excellent Vibration and shock
resistance.
25 to 27
High accuracy and stability.
Inexpensive compared with the
MgO sheathed RTDs.
45 to 49
Excellent vibration proof and shock
resistance compared with the other
standard types of thermocouples.
50 to 52
Sanitary designed sensor protected
from foreign materials and
microbiological contamination.
Suitable for usage in food, beverage,
chemical processes without concern
of contamination.
53 to 54
Chemical and humid resistant PFA
coated sensor.
PFA coated from the sensing point to
the lead wire.
55 to 56
T-80/T-85
K Type
T-90
750°C(950°C)
T-30/T-35
R,S Type
1400°C(1600°C)
B Type
Noble Metal
Thermocouples
1500°C(1700°C)
T-80
T-101S/T-111S
T Type
350°C
T-101S is protection tube 90° bend type.
T-30S/T-35S
J Type
Sheathed
Thermocouples
E Type
T-70S/T-75S
K
750°C
800°C
T-80S/T-85S
K Type
900°C
T-90S
T-101N/T-111N
K,N Type
1200°C
NICROBELL
Sheathed
Thermocouples
T-111N is protection tube 90° bend type.
T-30N/T-35N
R-101/R-111
R-111 is protection tube 90° bend type.
Pt100 Type
650°C
JPt100 Type
Resistance
Temperature
Detectors
R-102
R-30/35
500°C
R-90
R-101/R-111S
Pt100/Jpt100
Type
500°C
Sheathed
Resistance
Temperature
Detectors
R-30S/35S
R-90S
R-31S/36S
Pt100/Jpt100
Type
200°C
Pt100 Type
200°C
Sanitary type
Sheathed
Resistance
Temperature
Detectors
PFA (Fluororesin)
coated temperature
sensors
R-31RS/36RS
FT-100
(Thermocouple, Resistance FR-100
Temperature Detectors)
• For thermocouple, value is normal operating temperature limit while that of in ( ) is maximum operating temperature limit. For RTDs, it is operating temperature.
3
Temperature sensors for various applications
Measuring Range
Type • Usages
-200
0
Appearance
200 400 600 800 1000
Reference
page
Features
T-200/T-210
T Type
200°C(250°C)
The tip is going to be pressure welded to
the measured object by mounting
bracket.
T-201/T-211
29 to 31
T-201S/T-211S(Sheathed Thermocouple) Suitable for measurement of hot
runners, dies and moulds.
T-210 is protection tube 90° bend type.
K,J Type
300°C(400°C)
Bayonet type thermocouples
[Applications]
Plastic molding Cylinder
Molding die
Hot runner
K Type
550°C
T Type
200°C(250°C)
K,J Type
300°C(400°C)
T-211(S) is protection tube 90° bend type.
Thermocouple with bayonet. Length can
be easily adjusted.
T-202HS/T-212HS
Easy mounting is possible by moving the
bayonet cap dependent upon the
T-212HS is protection tube 90° bend type. insertion length.
Thermocouple with bayonet. Length can
T-220
be easily adjusted.
Decide the position of the mounting
bracket dependent upon insertion length
and fix the spring by fixed screw.
Thermocouple with bayonet. Length can
T-221
be easily adjusted.
Easy mounting is possible by moving the
bayonet cap dependent upon the
insertion length.
Sheathed Thermocouple for
High Temperature
Screwed Tip Thermocouples
T Type
200°C(250°C)
K,J Type
300°C(400°C)
T Type
200°C(250°C)
K,J Type
300°C(400°C)
T Type
200°C(250°C)
[Applications]
T-230
Plastic molding Cylinder
Molding die
Hot runner
Fixing screw type
thermocouples for surface
temperature measurement
Ring type thermocouples for
surface temperature
measurement
T-240
300°C(400°C)
K,J Type
400°C
Plastic molding Cylinder
Nozzle
Pipe shaped objects
Thermocouples for Resin
Temperature
T-260
[Applications]
Melting resin temperature of Extruder
K,J Type
400°C
Thermocouples for Resin
Temperature
Melting resin temperature of Extruder
K Type
300°C
K Type
300°C
[Applications]
500°C
Temperature Sensors for
Extremely Small Surface
ST-55
[Applications]
ST-56
Ceramic coating type
Surface of electronic parts
ST-100
Thermocouple Type
Non-Contacting Temperature
Sensors
K Type
300°C
ST-100K/K1
K Type
200°C(260°C)
K Type
300°C
34
Fix the sensor at a 4.5 fixed screw hole
of the tip with a screw.
Suitable for temperature measurement
for the tiny spaces.
34
Suitable for temperature measurement
for the pipe shaped objects and the
surface of the nozzles.
35
Capable of measurement of the molten
resin temperature, such as the inside of
the extruder. M16 screw is cut and its tip
directly touches to the melting resin.
36
By utilizing ZHF (zero-heat-flow) method, it
eliminates thermal disturbances and
temperature errors between the tip and the
outside case and realizes more precise
temperature measurement of the melting
resin.
36
ST-100
37 to 38
A fine thermocouple enables measurement
of a fine surface or a surface
39 to 41
with small thermal capacity such as SMT
parts.
ST-100K/ST-100K1
Capable of surface temperature
measurement of the rotating objects
42 to 43
such as rollers and sheets without direct
contact.
[Applications]
Surface temperature of Roller
and Rotationary objects
Rotationary Roll Surface
Temperature Measuring
Sensors
The tip is M6 size (M8 size is also
available) rotary screw. Internal screws
will be threaded in the fitting point.
*M6, M8 is based on JIS Standard.
An adhesive surface at the tip allows
easy attachment and measurement of
the surface temperature.
Exposed type is also available.
ST-50/ST-51
Surface of electronic parts
Fluorine resin coating type
K Type
33
*M16 is based JIS Standard.
T-270Z
[Applications]
Adhesive and exposed tip type
temperature sensors
33
T-250
[Applications]
K,J Type
32
JBS-3898
[Applications]
Capable of surface temperature
measurement of the rotating objects
such as rollers and sheets with direct
contact.
44
Rotationary Roll Surface
• Temperature value : Normal operating temperature limits, ( ) : Maximum operating temperature limits
Normal operating temperature limits and maximum operating temperature limits
Normal operating temperature limit is a temperature limit of sensors' continuous use in the air. It is a reference temperature that ±0.75% of thermo electromotive
force might not change with 10,000 hours of its successive use.
• For R, B, and S type, it is a reference temperature that ±0.5% of thermo electromotive force might not change with 2,000 hours of its successive use.
Maximum operating temperature limit is a limit of allowable temperature for short-term used in unavoidable situations. It is a reference temperature that ±0.75% of
thermo electromotive force might not change with 250 hours of successive use.
• For R, B, and S type, it is a reference temperature that ±0.5% of thermo electromotive force might not change with 50 hours of its continuous use.
(JIS C1602-1995)
4
Installation example
Fixed nipple (nut), Code : A
The insertion length is fixed (specify when you order) as for the nipple is
fixed on the protection tube.
Screw will be fit by welding at the fitting side or threading. Screw types will
be either tapered or parallel one.
Rotary nipple (nut), Code : B
The insertion length is fixed (specify when you order) as for the stopper of
nipple which is fixed on the protection tube.
Screw will be fit by welding or threading at the fitting side. Easy fitting is
realized because only the screw rotates.
There is no air tightness.
Available screw types are taper and parallel.
Fixed flange (Code : C)
The insertion length is fixed (specify when you order) as for the flange is
welded to the protection tube.
The flange will be welded to the fitting side in advance, and fixing it with
a bolt.
Sliding flange
The insertion length will be decided arbitrarily. The flange will be fixed at
the fitting part with a bolt, and fastened with screws. There is no air proof.
Screw
Compression fitting (Code : E)
The insertion length is freely adjustable. Weld a screw to the mounting
side or thread a hole for it. Screw the mounting bracket into the hole.
Determine the length and tighten the nut to fix
Bayonet type thermocouple
Thread a hole in advance on the mounting side and screw the
holder into the hole.
Hang the bayonet cap on the holder and fix it.
Temperature measuring junction is constantly pressed to the
measuring point with the spring force.
L shape type
Use an L-shaped type where a straight type is hard to install or
where lead wire/terminal box may be corroded or thermally affected.
5
Bayonet
Holder
Mounting Brackets
How to specify the length (L) of the protection tube with the mounting bracket.
For the sensor with fixed flange or fixed nipple, specify length (L)
by referring length of under the screw or under the flange.
If a space is required between the mounting bracket and the
sleeve or between the mounting bracket and the terminal box,
please specify it as well.
With fixed flange
For L shape sensors, mounting bracket will be
installed as the below picture.
* Please contact with our distributors in case
mounting bracket is needed to install to other
places.
L shape sensor
For the sensor with compression fitting, specify
length (L) by referring the terminal box and the
sleeve as the same order way without mounting
bracket.
With nipple
L1
L1
L1
50
L1
Flange
● JIS • FF flange (Fixed type) <Material : SUS304>
Unit:mm
Dimension
of Flange
Bolt Hole
h
Number
of Hole
12
12
12
12
15
15
15
19
15
15
15
19
19
19
19
19
19
19
19
23
23
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
8
4
4
8
8
8
* A collar will be equipped between
the fixed flange and the terminal box
if diameter of the protection pipe is
under φ10,
Collar
22
50
t
B
D
t
A
C
3/8
10
9
75
55
1/2
15
80
9
60
3/4
20
85
10
65
JIS 5K
25
1
10
95
75
h
Flange
40
11/2 120
12
95
50
2
14
130
105
65
21/2 155
14
130
C
80
3
180
14
145
D
3/8
10
12
90
65
1/2
15
12
95
70
3/4
20
100
14
75
25
1
125
14
JIS 10K
90
Flange
40
11/2 140
16
105
50
2
16
155
120
65
21/2 175
18
140
80
3
185
18
150
25
1
16
125
90
40
11/2 140
18
105
JIS 20K
50
2
18
155
Flange
120
65
21/2 175
20
140
80
3
22
200
160
How to Specify For JIS 5K flange, pleasse specify as JIS5K (fixed) flange 10A or specify as 3/8B.
L1
Name of Size
• RF flange is also available. Please specify when you order.
AxB
L
1
H
R (P.T)
AxB
10
12
15
18
22
22 or less 22
6
6
7
10
16
16
14×16.2
17×19.6
21×24.2
26×30
32×37
41×47.3
T-220 Holder Available model (Inner diameter d=5.2mm) : T-220,221,202SH,212SH
T-200 Holder Available model (Inner diameter d=7.2mm) : T-200,201,210,211
4
3
R (PT)1/8
2
H
10
L
How to Specify
Please specify as G or PF (parallel nipple) 1/8 •
R or PT(taper nipple) 1/8.
• Parallel nipple • taper nipple are both applied to
the fixed and rotary nipples.
3
12
G (P.F)
Taper Screw
L
3
Diameter of
G(PF)/R(PT) protection tube
1/8
6 or less
1/4
8 or less
3/8
10 or less
1/2
12 or less
3/4
16 or less
H
+0.2
0
Parallel Screw
L
Holder
Unit:mm
d
Nipple (nut) <Material : SUS304>
Screw : R(PT)1/8
L=32,40,62
(Please specify when you order)
• Different types of screws
are also available.
AxB
Compression Fitting
<Fastening Ring Material : SUS304>
Push screw type
Cap nut type
L
L
A
L1
A
B
L2
L3
L1
Unit:mm
Diameter of
R(PT) protection tube
1/8
1/4
1.6
3.2
4.8
3.2
4.8
6.4
8.0
L L1 L2 L3
33
33
35
37
38
38
41
10
10
10
14
14
14
14
6
6
6
6
6
6
6
12
12
14
12
14
14
16
A
B
12×13.7 12×13.7
12×13.7 12×13.7
12×13.7 14×16.2
14×16.2 12×13.7
14×16.2 14×16.2
14×16.2 14×16.2
17×19.6 17×19.6
of
R(PT) Diameter
protection tube
3.2
4.8
3/8
6.4
8.0
3.2
4.8
1/2
6.4
8.0
L2
B
L3
Unit:mm
L L1 L2 L3
39
40
45
44
43
44
49
48
16
16
16
16
20
20
20
20
15
15
19
19
15
15
19
19
5
5
5
5
5
5
5
5
A
B
22×25.4
22×25.4
22×25.4
22×25.4
24×27.7
24×27.7
24×27.7
24×27.7
14×16.2
14×16.2
17×19.6
17×19.6
14×16.2
14×16.2
17×19.6
17×19.6
6
Lead wire termination
Lead wire termination
For lead wire termination (compensation wire and copper wire), Spade lugs, Ring lugs, connector, and TC type connector are
available. We also can provide requested termination type.
Spade lugs
Ring lugs
JIS standard "M3" size screw
Thermocouple connectors
JIS standard "M4" size screw
Composition of the leadwire will be as follows [(plug) + (clamp) + (jack)]
when TC connector [code : TE] is specified. For other types and combinations,
please refer to p.10.
Jack
4
20
V1.25-B3A
V1.25-M4
(Manufactured by J.S.T MFG CO., LTD.)
15
30
36.4
12.4
20
25.4
4.7
6.5
3.2
5.8
4.3
Plug
(Manufactured by J.S.T MFG CO., LTD.)
Model Code : CSP02-
Model Code : CSP01-
Metal connectors
Composition of the lead wire will be [(plug) + (receptacle)] when metal connector is specified as termination.
* Connector is manufactured by Sanwa Connector Laboratory Co., Ltd..
Composision of the lead wire will be (adaptor) + (plug) when adaptor is specified as termination.
* Connector is manufactured by Sanwa Connector laboratory Co., Ltd..
Metal connector manufactured by Nanaboshi Electric Mfg. Co., Ltd. is also available.
Manufactured by Sanwa Connector Laboratory Co., Ltd. (Standard)
Receptacle
M18P:1
Adaptor
M18P:1
Panel Cutout
1
4
11
42
7
3-3.2
3-3.2
23
+0.3
0
18
8
21
14.5
16
32
14.5
14
21
18
8
5
6.
2
M18P:1
2
4
Plug
43
Specification
Model Code
Specification
Model Code
Specification
Model Code
Thermocouple (Single element)
Thermocouple (Double element)
Resistance Temperature Detector
(Single element)
Resistance Temperature Detector
(Double element)
SCK-1602-P
SCK-1604-P
SCK-1603-P
Thermocouple (Single element)
Thermocouple (Double element)
Resistance Temperature Detector
(Single element)
Resistance Temperature Detector
(Double element)
SCK-1602-R
SCK-1604-R
SCK-1603-R
Thermocouple (Single element)
Thermocouple (Double element)
Resistance Temperature Detector
(Single element)
Resistance Temperature Detector
(Double element)
SCK-1602-A
SCK-1604-A
SCK-1603-A
4
1
2
SCK-1606-A
Adaptor
M18P:1
Panel Cutout
4
Manufactured by Nanaboshi Electric Mfg. Co., Ltd.
Receptacle
Plug
M18P:1
M18P:1
11.5
SCK-1606-R
2
SCK-1606-P
Specification
8
26
Specification
Thermocouple (Double element)
Resistance Temperature Detector
(Double element)
28.5
22
Model Code
Specification
NCS-254-P
NCS-256-P
Thermocouple (Double element)
Resistance Temperature Detector
(Double element)
Model Code
NCS-254-R
NCS-256-R
Connector has 2 types. One is "Female connector type (standard), the other one is "Male connector type".
Female connector type (standard)
Male connector type
Specification
Specification
Socket insert plug
Pin insert plug
Pin insert receptacle
Pin insert adaptor
2 1
7
+
Specification
Model Code
Thermocouple (Double element)
Resistance Temperature Detector
(Double element)
NCS-254-Ad
NCS-256-Ad
Plug
Socket insert receptacle
Pin insert adaptor
Pin numbers and polarity (standard)
-
57
3-M3 or 3.4 ±0.2
3-M3
(Double
- +
element) 4
1
3
+ -
2
20
4
3
3
4
25
22
42
28.5
21.4
11.5
50
(Single
element)
Adaptor
M25x1.25
Panel Cutout
M25x1.25
Model Code
Thermocouple (Single element) NCS-162-Ad-CH
Resistance Temperature Detector NCS-163-Ad-CH
(Single element)
Receptacle
13
8.5
Model Code
6
2
22.3
M25x1.25
22.9
14.8
Specification
NCS-162-R-CH
Thermocouple (Single element)
Resistance Temperature Detector NCS-163-R-CH
(Single element)
(There are some changes in codes dependent upon production
companies. For Sanwa Connector Laboratory Co., Ltd., NCF
will be SCH. For Nanaboshi Electric Mfg. Co., Ltd., plugged
end connector will be P to PM, receptacle will be R to RF,
and adaptor will be Ad to AdF.
23.5
Model Code
42.5
11.5
Specification
3-M3 or 3.4 ±0.2
3-M3
23
NCS-162-P-CH
Thermocouple (Single element)
Resistance Temperature Detector NCS-163-P-CH
(Single element)
Plug
16
14.8
32
21.5
20
8.5
14.3
7
7.3
44
Pin insert
Socket insert
(Female connector) (Male connector)
Terminal head • Measuring junction • Tip processing • Lead wire termination
Terminal head
Enclosed-terminal
30 type Terminal Head
Enclosed-terminal
35 type Terminal Head
(10)
(6)
Lead wire
output port
(82)
Aluminum die cast
PF3/8
• Thermocouple : 2
Number of Terminals • Resistance temperature
detector : 3
Terminal board Material
Steatite porcelain
Available
Metal
3 to 10
diameter
6 to 10
of protection tube Non-metal
Coating Color
Silver
(43)
(17)
(53)
(22)
PF1/2
Lead wire
output port
Aluminum die cast
PF1/2
• Thermocouple : 2, 4
• Resistance temperature
detector : 3, 6
Steatite porcelain
4.8 to 22
6 to 17
Silver
Material
Lead wire output port
Specifications
(70)
(48)
(38)
(88)
(65)
6)
PF3/8
(60)
Exposed terminal
85 type Terminal Head
78
(5
Appearance
Unit:mm
Exposed terminal
80 type Terminal Head
(43)
Name
Phenol resin
Exposed terminal
Phenol resin
Exposed terminal
Thermocouple : 2
Thermocouple : 2
Phenol resin
3 to 10
6 to 10
Black
Phenol resin
4.8 to 22
6 to 17
Black
Measuring junction
Ungrounded (Example of Thermocouple)
Grounded (Example of Thermocouple)
Thermocouple wires are directly welded to the sheath
end. As response is faster, it is suitable for measurement
under high temperature and high pressure condition. It is
not recommended in the presence of hazard and noise
voltages because wires are directly welded to the sheath
end.
Type
General type
Thermocouple
Sheathed type
Resistance
General type
temperature
Sheathed type
detector
Grounded
Available
Available
Not available
Not available
Completely insulated between the thermocouple
element/resistance element and the sheath.
The Hot junction is also insulated.
Response is slower than the grounded type.
Less EMF change by time.
Can be used for a comparatively long period of time.
Not affected by noise voltage.
Exposed (Example of Thermocouple)
Thermocouple wires are exposed from the sheath.
As response is fastest, it can follow even a little
temperature change. Avoid being used over a long
period of time under corrosive atmosphere or high
temperature and high pressure conditions due to no air
tightness and mechanical strength.
Ungrounded Exposed
Available
Available
Available
Available
Available
Available
Available
Not available
Tip processing
Features
Maximum heat resistance degree for welding is 500ºC. Not suitable for food and plating applications since it is largely
Silver soldering affected by corrosive.
Argon welding Non-MgO sheathed sensors for high temperature use are welded by argon. All of MgO sheathed sensors are welded by argon.
Type
Lead wire termination
Spade lugs for JIS standard "M3" size screw
80
Thermocouple connector
Length of Lead Wire (L)
Length of Lead Wire (L)
Ring lugs for JIS standard "M4" size screw
80
Metal connector
Length of Lead Wire (L)
Length of Lead Wire (L)
No terminal lugs *terminal soldered
80
Length of Lead Wire (L)
8
Thermocouple Connectors
If standard connector is used for connecting compensating cables for thermocouple, it will cause indication error
because the materials of connection terminals differ from those of leadwires and compensation cables.
By using connectors for thermocouple, accuracy of thermocouple can be maintained because connection terminals
of the connector are the same materials with thermocouple. There is no concern of intervention of different types of
metals.
Recommended tightening torque : 1.5kgf•cm
Applicable Sheathed diameter : 2.8 to 6mm
Standard Size (Polyamide) CSP
CSP01-
(Jack)
(Panel Jack)
ø4.7
ø4
+
12.5
30
–
25.4
(Plug)
CSP02–
+
15
36
12.5
CSP03Panel cutout dimension
13
25.5
CSP03-
–
CSP02-
25.4
CSP01-
36.7
+
CSP03-
K
18.6
27.7
Recommended tightening torque : 1.5kgf•cm
Applicable Sheathed diameter : 2.8 to 6mm
Standard Size : For High temperature (Ceramic) CSC
(Plug)
(Jack)
CSC01-
CSC02ø4.7
25.4
K
ø4
+
12.5
30
15
37
Recommended tightening torque : 1.5kgf•cm
Applicable Sheathed diameter : 0.5 to 4mm
CMP02-
Miniature Size (Polyamide) CMP
2.3x0.8
(Panel Jack)
+
8
21
16.5
(Jack)
3x0.8
K
K
CMP01-
+
26
13
+
3
8
2-ø2.7
Recommended tightening torque : 1.5kgf•cm
Applicable Sheathed diameter : 0.5 to 4mm
CMR02-K
CMR01-K
2.3x0.8
+
8
CMR01-K
CMR02-K
21
13
16.5
3x0.8
K
K
(Jack)
26
K
Miniature Size : For High temperature (Ryton) CMR
(Plug)
22.5
16.9
22.5
16.5
CMP03-
K
CMP02-
8
CMP03Panel cutout dimension
8.4
CMP03-
CMP01-
12.5
CSC02-
CSC01-
(Plug)
+
+
26
• Standard type for high temperature applications (Ryton) : CSR
Please contact with our distributors.
8
- K is available.
• 3 thermocouple types are available : K, J, and T. (R type is available for polymaide miniature.)
• Color of K type connector is yellow, J type is black, and T type is blue.
(If ryton is a material for the connector, its color is brown. This is only for K type)
Please note that color of each lead wire is different.
• The attached rubber packing and metal adaptor
Please use rubber seal or metal adapter to stabilize in case the hole size of connector is too bigger against the size of compensation cable or MgO
sheathed tube. To stabilize connection, slide rubber seal or metal adapter into the groove of thermocouple connector.
Either of seal rubber or metal adapter is standard accessory.
9
Thermocouple Connectors
Model Code
Material
Model and Suffix Code
Specifications
C
Standard Size (Polyamide) Max.120ºC SP
Standard Size (Ceramic)
Max.900ºC SC
Connector
*2
Miniature Size (Polyamide)
Max.120ºC MP
Material
Miniature Size (Ryton) *1, *3 Max.220ºC MR
Plug
01
Jack
02
Type
Panel Jack
03
Plug + Jack
12
13
Plug + Panel Jack
K : Yellow
K
Thermocouple J : Black
J
Type
T : Blue
T
*1 : For the miniature size (ryton), only K is available. Its color is brown.
*2 : For the miniature type (polyamide), R is also available. Its color is
green. Please select "R" at thermocouple material code.
*3 : Standard type (ryton) K is also available. Please contact with our
distributors.
Polyamide
Ceramic
Polyamide
Ryton
Type
Model Code
Standard Size (Plug + Jack)
CSP12Standard Size (Plug + Panel Jack) CSP13Standard Size (Plug)
CSP01Standard Size (Jack)
CSP02Standard Size (Panel Jack)
CSP03CSC12Standard Size (Plug + Jack)
CSC01Standard Size (Plug)
Standard Size (Jack)
CSC02Miniature Size (Plug + Jack)
CMP12Miniature Size (Plug + Panel Jack) CMP13Miniature Size (Plug)
CMP01Miniature Size (Jack)
CMP02Miniature Size (Panel Jack)
CMP03Miniature Size (Plug + Jack)
CMR12-K
Miniature Size (Plug)
CMR01-K
Miniature Size (Jack)
CMR02-K
Lead Clamp
CLP-A
Lead Clamp Application
CLP-B
(For miniature size)
1.5 - 3.2
2.8 - 6.5
(For standard size)
Model and suffix code for thermocouple connector with lead wire
Model Code
TE
TS1
TS2
TS3
TS4
TSA
TSB
TM1
TM2
TM3
TM4
TM5
TMA
TMB
CSP01 + CLP-A + CSP02
CSP01 + CLP-A
CSP01
CSP01 + CLP-A + CSP03
CSP01 + CSP02
CSP02 + CLP-A
CSP02
CMP01 + CLP-B
CMP01
CMP01 + CLP-B + CMP03
CMP01 + CLP-B + CMP02
CMP01 + CMP02
CMP02 + CLP-B
CMP02
Type
Standard Size (Plug + Clamp + Jack)
Standard Size (Plug + Clamp)
Standard Size (Plug)
Standard Size (Plug + Clamp + Panel Jack)
Standard Size (Plug + Jack)
Standard Size (Jack + Clamp)
Standard Size (Jack)
Miniature Size (Plug + Clamp)
Miniature Size (Plug)
Miniature Size (Plug + Clamp + Panel Jack)
Miniature Size (Plug + Clamp + Jack)
Miniature Size (Plug + Jack)
Miniature Size (Jack + Clamp)
Miniature Size (Jack)
• For the other types, please contact with our distributors.
10
General purpose type • Sheathed Thermocouples
Thermocouple
A thermocouple consists of two dissimilar metallic wires, edge of
its each wire is jointed, and measures a voltage produced according
to a difference of the temperatures through each metallic wire.
This effect is called Seebeck effect and has been known from long
time ago.
If a combination of two dissimilar metallic wires are correct, their
thickness or shapes do not effect on temperature measurement.
This type of sensor excels in processability for this reason,
thus it is widely used in industrial plants.
A
T2
T1
T1,T2 : Temperature
A,B : Metallic wires
B
Internal structure of Thermocouple
Sheathed Thermocouple
Insulator(Magnesium oxide) is mounted between the protection tube
and the measuring element.
This type of sensor features in excellent responsiveness and vibration
resistances.
General type
Protection Tube
Thermocouple Element
Insulator or glass fiber
Spring loaded type
Sheathed type
Protection Tube
Thermocouple Element
Magnesium oxide (MgO)
Terminal head type
(Only for General type)
T-30,35(General type)
T-30S,35S(Sheathed type)
T-100
T-110
Thermocouple connector type
K
T-70S,75S(Sheathed type)
Exposed terminal head type
Sleeve type
T-80,85(General type)
T-80S,85S(Sheathed type)
T-101(General type)
T-101S(Sheathed type)
T-111(General type)
T-111S(Sheathed type)
Metal connector type
T-90(General type)
T-90S(Sheathed type)
Noble Metal type
Protection tube is porcelain
No-sleeve type
(Only for General type)
T-30,35
T-102
T-80
11
(For High Temperature)
Lead wire
(Compensation
lead wire)
L2
Red
(+)
Black
(-)
K:180
T,J:150
Spring
Lead wire
(Compensation
lead wire)
L
Lead wire
termination
Red
(+)
Black
(-)
K:180
T,J:150
120°
L1
Lead wire
termination
10
Spring
L1
Silver soldering
Protection
tube
120°
(SUS304)
10
d
Thermocouples : T-100/T-110
L
Protection
tube
(SUS304)
Silver soldering
d
T - 100 - d - L1 - L -
T - 110 - d - L1 - L2 - L -
- - - -
Diameter of protection tube
- - - Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Length of protection tube
Example :T-100-5-100-2000-EXA-Y-K-G-N
Diameter of
protection tube
Thermocouple type
Example :T-110-5-100-30-2000-EXA-Y-K-G-N
5.0, 6.0
Length of
protection tube
Specify length by “mm” (100mm to 1,000mm)
Lead wire length
Specify length by “mm” (100mm or more)
Specify length by “mm”
(100mm or more, L1+L2=1,000mm or less)
Specify length by “mm”
(25mm or more, L1+L2=1,000mm or less)
• Length is 25mm without specification.
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Lead protection
Code
EXA
EXB
Details
Fiberglass with stainless steel
Fiberglass
Operating temperature
0 to 150ºC
0 to 150ºC
Lead wire
termination
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Thermocouple type
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Measuring junction
Mounting bracket
Code
G
NG
Code
E
N
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
Details
Grounded
Ungrounded
Details
Compression fitting
No bracket
• Specify size of mounting braket when code is "E".
Class : class 2
Element : Single element
* Class 1 is available (Please specify when you order)
* Double element is available (Please specify when you order)
Maximum temperature for use
Thermocouple
type
Operating temperature
for regular use
Maximum
temperature
300ºC
300ºC
200ºC
400ºC
400ºC
250ºC
K
J
T
Specifications
• Stainless flexible lead wire is available
Model Code : T-100F/T-110F
Reference
SUS304
Compensation lead wire (Fiberglass)
• No waterproof
12
Thermocouples : T-101/T-111
Argon welding
D1
120°
Serial number
Heat shrink
label
tube
L
Specification
label
L1
Lead wire
termination
Serial number Heat shrink
label
tube
Specification
label
Red
(+)
Black
(-)
L
40
Protection tube
(SUS316)
Argon welding
120°
40
D1
Red
(+)
Black
(-)
L1
Protection
tube
(SUS304)
d
Hexagon
Sleeve is
Lead wire
Crimp
Sleeve filled with epoxy (Compensation
(MAX 120ºC)
lead wire)
L2
Sleeve is
filled with epoxy Lead wire
(MAX 120ºC) (Compensation Lead wire
termination
Sleeve
lead wire)
Hexagon
Crimp
(3, 3.2 Grounded Type :
Silver soldering)
(3, 3.2 Grounded Type :
d Silver soldering)
T - 101 - d - L1 - L -
T - 111 - d - L1 - L2 - L -
- - - -
Diameter of protection tube
- - - Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Mounting bracket
Lead protection
Mounting bracket
Lead protection
Length of protection tube
Example :T-101-5-100-2000-EXA-Y-K-G-N
Diameter of
protection tube
Thermocouple type
Example :T-111-5-100-30-2000-EXA-Y-K-G-N
3.0, 3.2, 4.8, 5.0, 6.0, 6.4, 8.0
Length of
protection tube
Specify length by “mm” (100mm to 1,000mm)
Lead wire length
Specify length by “mm” (100mm or more)
Specify length by “mm”
(100mm or more, L1+L2=1,000mm or less)
Specify length by “mm”
(25mm or more, L1+L2=1,000mm or less)
• Length is 25mm if not specified.
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Lead protection
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Lead wire
termination
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Thermocouple type
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Operating temperature
-20 to +90ºC
-55 to +180ºC
0 to 200ºC
Details
PVC (polyvinyl chloride)
Silicone rubber
Fluorocarbon polymers (FEP)
Code
EXD
EXE
EXF
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded
* Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Exposed *
Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting braket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
• Please contact distributors regarding other mounting bracket.
Class : class 2
* Class 1 is available (Please specify when you order)
Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more)
(Please specify when you order)
Maximum temperature for use
Specifications
K
J
T
E
3.0 to 3.2
4.8 to 6.4
8.0
3.0 to 3.2
4.8 to 6.4
8.0
4.8 to 6.4
8.0
3.0 to 3.2
4.8 to 6.4
8.0
300ºC
650ºC
750ºC
200ºC
400ºC
450ºC
200ºC
250ºC
200ºC
450ºC
500ºC
400ºC
850ºC
950ºC
300ºC
500ºC
550ºC
250ºC
300ºC
300ºC
500ºC
550ºC
• Stainless flexible lead wire is available
Model Code : T-101F/T-111F
Reference
Compensation lead wire
(Fiberglass)
For flexible lead wire, the dimension of the sleeve is
10 x 40mm.(Lead protection EXB type is same to
standard specification.)
• No waterproof
13
400ºC
400ºC
400ºC
300ºC
400ºC
400ºC
250ºC
300ºC
300ºC
400ºC
400ºC
Diameter of
protection tube
Lead
3.0 to 5.0
wire type
EXA,EXB,EXC
EXD,EXF
EXE
6.0 to 8.0
8×40
10×40
10×40
5
40
• Spring loaded type is available
(Please specify when you order)
MAX 120ºC
SUS304
300ºC
300ºC
300ºC
200ºC
300ºC
350ºC
200ºC
250ºC
200ºC
300ºC
300ºC
Sleeve Dimension (D1)
D1
T-101
T-111
Thermocouple Diameter of
Operating
type
protection tube Operating
Maximum
temperature Maximum
temperature
for regular use temperature for regular use temperature
• Material of protection tube
SUS316 is available.
(Please specify when you order)
Sleeve is
Lead wire
filled with epoxy Spring
(Compensation
(MAX 120ºC) (SUS304) lead wire)
Sleeve
70
L
Dimensions for the spring loaded sleeve is as follows.
• Protection tube 8 with extension lead wire EXA, EXB, EXD : 10 x 40mm
• Protection tube 3.0 to 8.0 with extension lead wire EXC : 10 x 40mm
• Except trom the above: : 8 x 40mm
Thermocouples : T-102
Silver soldering
(Ungrounded Type :
Argon welding) Protection
tube
(SUS304)
120°
Diameter of protection tube (d) : 4.0 or more
*1
Lead wire
Hexagon Crimp or
(Compensation
Filled with Epoxy Resin lead wire)
Serial number
Heat shrink
label
tube
L1
Silver soldering
(8 or Ungrounded Type : Argon welding)
Lead wire
termination
d
d
Diameter of protection tube (d) : 3.0, 3.2
Red
(+)
Black
(-)
120°
Protection
tube (SUS304) Hexagon
Crimp
Lead wire
termination
Serial number
Heat shrink
label
tube
L1
L
Lead wire
(Compensation
lead wire)
Red
(+)
Black
(-)
L
*1:Fiber glass lead protection (EXB) : Hexagon Crimp
Fluorocarbon polymers lead protection (EXF) : Filled with Epoxy Resin
T - 102 - d - L1 - L -
T - 102 - d - L1 - L -
- - - -
- - - -
Diameter of protection tube
Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Example :T-102-5.0-300-2000-EXA-Y-K-G-N
Example :T-102-3.2-300-2000-EXA-Y-K-G-N
Diameter of
protection tube
Length of
protection tube
Lead wire length
Lead protection
Lead wire
termination
Thermocouple type
4.0, 4.8, 5.0, 6.0, 8.0
3.0, 3.2
Specify length by “mm” (30mm to 500mm)
• Please contact distributors regarding other length.
Specify length by “mm” (100mm to 10,000mm)
• Please contact distributors regarding other length.
Details
Code
EXB Fiberglass
EXF Fluorocarbon polymers (FEP)
Operating temperature
0 to 150ºC
0 to 200ºC
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXE Silicone rubber (Only for 4.8, 5.0, Type K) -20 to +90ºC
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded
Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting braket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
• Please contact distributors regarding other mounting bracket.
* Class 1 is available (Please specify when you order)
Class : class 2
Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more)
(Please specify when you order)
Maximum temperature for use
Specifications
Thermocouple
type
K
J
T
Operating temperature for regular use
Lead protection (Code)
EXA
300ºC
300ºC
200ºC
EXB
300ºC
300ºC
200ºC
EXE
180ºC
180ºC
180ºC
EXF
200ºC
200ºC
200ºC
Maximum temperature
Lead protection (Code)
EXA
400ºC
400ºC
250ºC
EXB
400ºC
400ºC
250ºC
EXE
EXF
• Spring loaded type is available
(Please specify when you order)
Lead wire
Spring
(Compensation
(SUS304) lead wire)
70
Reference
L
• Material of protection tube
SUS316 is available.
(Please specify when you order)
14
Thermocouples : T-30/T-35
(3, 3.2 Grounded Type :
Silver brazing)
Protection tube
(SUS304)
120° (10 or more
:Hemisphere)
Specification
label
Terminal head
Serial number
label
L1
d
d
Argon welding
60
120° (10 or more
:Hemisphere)
PF3/8
Serial
number
label
PF1/2 82
L1
No lead wire
T - 30 - d - L1 - - With lead wire
T - 30 - d - L1 - L -
Protection tube Specification Terminal head
(SUS304)
label
Argon welding
No lead wire
T - 35 - d - L1 - - With lead wire
T - 35 - d - L1 - L -
- - - Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
- - - Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Example :T-30-5-100-K-G-N (No lead wire)
:T-30-5-100-2000-EXA-Y-K-G-N (With lead wire)
Example :T-30-5-100-K-G-N (No lead wire)
:T-30-5-100-2000-EXA-Y-K-G-N (With lead wire)
4.8, 5.0, 6.0, 8.0, 10.0, 12.0, 15.0
Diameter of
protection tube
3.0, 3.2, 4.8, 5.0, 6.0, 8.0, 10.0
Length of
protection tube
Specify length by “mm” (100mm to 1,000mm)
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Lead wire length
Lead wire
termination
Specify length by “mm” (100mm or more)
No need to specify in case of
without lead wire
Lead
protection
• Please contact distributors regarding 21.7.
Thermocouple type
Measuring junction
Mounting bracket
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
•See Page7
M Metal connector (SCK-1602-P)
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Code
G
NG
O
Details
Grounded
Ungrounded
Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Please contact with our distributors.
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Class : class 2
Element : Single element
Specify size of mounting bracket when code is
"A", "B", or "E".
Specify size of flange when code is "C".
* Class 1 is available (Please specify when you order)
* Double element is available. (Only for T-35)
(Please specify when you order)
Maximum temperature for use
Protection tube : SUS304
Operating
Thermocouple Diameter of
temperature Maximum
type
protection tube for regular use temperature
Specifications
K
J
T
E
3.0 to 3.2
4.8 to 6.0
8.0 or more
3.0 to 3.2
4.8 to 6.0
8.0 or more
3.0 to 6.0
8.0 or more
3.0 to 3.2
4.8 to 6.0
8.0 or more
• Material of protection tube
SUS316 is available.
(Please specify when you order)
Reference
15
Operating temperature
-20 to +90ºC
-55 to +180ºC
300ºC
650ºC
750ºC
200ºC
400ºC
450ºC
200ºC
250ºC
200ºC
450ºC
500ºC
400ºC
850ºC
950ºC
300ºC
500ºC
550ºC
250ºC
300ºC
300ºC
500ºC
550ºC
• High temperature type
Thermocouple type R, S, B for high temperature type :
See page 18.
Thermocouples : T-80/T-85
Argon welding
Terminal
head
17
43
L1
No lead wire
T - 80 - d - L1 - - With lead wire
T - 80 - d - L1 - L -
With lead wire
T - 85 - d - L1 - L -
- - - Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
22
- - - Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Example :T-80-5-100-K-G-N (No lead wire)
:T-80-5-100-2000-EXA-Y-K-G-N (With lead wire)
Example :T-85-5-100-K-G-N (No lead wire)
:T-85-5-100-2000-EXA-Y-K-G-N (With lead wire)
4.8, 5.0, 6.0, 8.0, 10.0, 12.0, 15.0
Diameter of
protection tube
3.0, 3.2, 4.8, 5.0, 6.0, 8.0, 10.0
Length of
protection tube
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding 21.7.
• Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
No need to specify in case of
without lead wire
Lead wire length
Lead wire
termination
53
No lead wire
T - 85 - d - L1 - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Lead
protection
Terminal
head
120° (10 or more
:Hemisphere)
43
L1
Protection tube
(SUS304)
70
d
120° (10 or more
:Hemisphere)
d
Protection tube
(SUS304)
Argon welding
Specification label
(Reverse side:Serial number label)
Specification label
(Reverse side:Serial number label)
Thermocouple type
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
•See Page7
M Metal connector (SCK-1602-P)
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Operating temperature
-20 to +90ºC
-55 to +180ºC
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded
Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Specify size of mounting bracket when code is
"A", "B", or "E".
Specify size of flange when code is "C".
Class : class 2
Class : class 2
* Class 1 is available (Please specify when you order)
* Class 1 is available (Please specify when you order)
Element : Single element
Element : Single element
Maximum temperature for use
Protection tube : SUS304
Operating
Thermocouple Diameter of
temperature Maximum
type
protection tube for regular use temperature
Specifications
K
J
T
E
3.0 to 3.2
4.8 to 6.0
8.0 or more
3.0 to 3.2
4.8 to 6.0
8.0 or more
3.0 to 6.0
8.0 or more
3.0 to 3.2
4.8 to 6.0
8.0 or more
300ºC
650ºC
750ºC
200ºC
400ºC
450ºC
200ºC
250ºC
200ºC
450ºC
500ºC
400ºC
850ºC
950ºC
300ºC
500ºC
550ºC
250ºC
300ºC
300ºC
500ºC
550ºC
Maximum temperature for use
Protection tube : SUS304
Operating
Thermocouple Diameter of
temperature Maximum
type
protection tube for regular use temperature
K
J
T
E
4.8 to 6.0
8.0 or more
4.8 to 6.0
8.0 or more
4.8 to 6.0
8.0 or more
4.8 to 6.0
8.0 or more
650ºC
750ºC
400ºC
450ºC
200ºC
250ºC
450ºC
500ºC
850ºC
950ºC
500ºC
550ºC
250ºC
300ºC
500ºC
550ºC
• Material of protection tube
SUS316 is available.
(Please specify when you order)
Reference
• High temperature type
Thermocouple type R, S, B for high temperature type :
See page 19.
16
d
Thermocouples : T-90
Argon welding
120°
Serial
number
label
Protection tube
(SUS304)
L1
Adapter
(SCK-1602-A)
Plug
(SCK-1602-P)
43
42
No lead wire
T - 90 - d - L1 - - With lead wire
T - 90 - d - L1 - L -
- - - Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Example :T-90-5-100-K-G-N (No lead wire)
:T-90-5-100-2000-EXA-Y-K-G-N (With lead wire)
Lead
protection
Lead wire
termination
No need to specify in case of
without lead wire
Diameter of
protection tube
Length of
protection tube
Lead wire length
Thermocouple type
3.0, 3.2, 4.8, 5.0, 6.0, 8.0
Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
•See Page7
M Metal connector (SCK-1602-P)
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded
Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Specify size of mounting bracket when code is
"A", "B", or "E".
Specify size of flange when code is "C".
Class : class 2 * Class 1 is available (Please specify when you order)
Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more)
(Please specify when you order)
Maximum temperature for use
Protection tube : SUS304
Operating
Thermocouple Diameter of
temperature Maximum
type
protection tube for regular use temperature
Specifications
3.0 to 3.2
4.8 to 6.0
8.0
3.0 to 3.2
4.8 to 6.0
8.0
3.0 to 6.0
8.0
3.0 to 3.2
4.8 to 6.0
8.0
K
J
T
E
300ºC
650ºC
750ºC
200ºC
400ºC
450ºC
200ºC
250ºC
200ºC
450ºC
500ºC
400ºC
850ºC
950ºC
300ºC
500ºC
550ºC
250ºC
300ºC
300ºC
500ºC
550ºC
Connector
Pin No.
Double Element
Single Element
2 1
Reference
SCK-1602-
Pin No. Details
1
2
4
3
1
2
SCK-1604-
Pin No. Details
1
2
3
4
For connector for T-90, Connector manufactured by Sanwa Connector Laboratory Co., Ltd. is used as standard.
Nanaboshi Electric Mfg brand is also available (Please specify when you order).
Please specify in case of no need of the plug.
17
Operating temperature
-20 to +90ºC
-55 to +180ºC
Noble Metal Thermocouples : T-30/T-35 (For High Temperature)
Terminal head
Collar
Specification
label
Protection tube
(Porcelain tube PT1, etc)
d
d
Terminal head
Protection tube
(Porcelain tube PT1, etc)
Collar
Serial number
label
Serial number
label
L2
(30)
L2
L1
60
PF3/8
Diameter of protection tube
Length of protection tube (L1)
Length of protection tube (L2)
(50)
L1
No lead wire
T - 30 - d - L1 - L2 - - With lead wire
T - 30 - d - L1 - L2 - L -
82
PF1/2
No lead wire
T - 35 - d - L1 - L2 - - With lead wire
T - 35 - d - L1 - L2 - L -
- - - -
Diameter of protection tube
Length of protection tube (L1)
Length of protection tube (L2)
Thermocouple type
Sensing junction
Mounting bracket
Lead wire length
Lead protection
Lead wire termination
Example :T-30-10-200-170-R-NG-N (No lead wire)
:T-30-10-200-170-2000-EXA-Y-R-G-N (With lead wire)
- - - -
Lead wire length
Lead protection
Lead wire termination
6.0, 8.0, 10.0, 13.0, 15.0, 17.0
Length of
protection tube
(L1)
Specify length by “mm” (130mm to 1,030mm)
Specify length by “mm” (150mm to 1,050mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Length of
protection tube
(L2)
Specify length by “mm” (100mm to 1,000mm)
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Lead wire length
Specify length by “mm” (100mm or more)
Lead wire
termination
No need to specify in case of
without lead wire
6.0, 8.0, 10.0
Thermocouple type
Details
Code
EXA Fiberglass with stainless steel
EXB Fiberglass
EXD PVC (polyvinyl chloride)
Thermocouple type
Sensing junction
Mounting bracket
Example :T-35-10-200-150-R-NG-N (No lead wire)
:T-35-10-200-150-2000-EXA-Y-R-G-N (With lead wire)
Diameter of
protection tube
Lead
protection
Specification
label
Operating temperature
0 to 150ºC
0 to 150ºC
-20 to +90ºC
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
R Ring lugs for JIS standard "M4" size screw
Only for Type R
N
No terminal lugs *terminal soldered •See Page7
M Metal connector (SCK-1602-P)
*1 : Other thermocouple connector :
See Page 10
Code
Code
Details
Details
R Type R (Platinum - Platinum Rhodium13%)
B Type B(Platinum - Platinum Rhodium6%)
S Type S (Platinum - Platinum Rhodium10%)
Measuring junction
Code
NG
Details
Ungrounded
Mounting bracket
Code
C
N
Details
Fixed flange
No bracket
Specify size of flange when code is "C".
• Please contact distributors regarding other mounting bracket.
Class : class 2
* Class 1 is available. (Thermocouple type : R,S)
(Please specify when you order)
Element : Single element * Double element is available. (Only for T-35)
(Please specify when you order)
Maximum temperature for use
Thermocouple
type
Specifications
R
S
B
Operating
temperature
for regular use
Maximum
temperature
1400ºC
1400ºC
1500ºC
1600ºC
1600ºC
1700ºC
*The lists above are operating temperature limits
for the element wire. For the protection tube,
please refer to page.58 about reference data of
protection tube.
Reference
18
Noble Metal Thermocouples : T-80/T-85 (For High Temperature)
Terminal
head
Collar
Terminal
head
70
d
Protection tube
Collar
(Porcelain tube PT1, etc)
Specification label
(Reverse side:Serial number label)
Protection tube
(Porcelain tube PT1, etc)
43
d
Specification label
(Reverse side:Serial number label)
(30)
L2
L2
L1
43 17
No lead wire
T - 80 - d - L1 - L2 - - With lead wire
T - 80 - d - L1 - L2 - L Diameter of protection tube
Length of protection tube (L1)
Length of protection tube (L2)
With lead wire
T - 85 - d - L1 - L2 - L Thermocouple type
Sensing junction
Mounting bracket
Lead wire length
Lead protection
Lead wire termination
Example :T-80-10-200-170-R-NG-N (No lead wire)
:T-80-10-200-170-2000-EXA-Y-R-G-N (With lead wire)
6.0, 8.0, 10.0
Length of
protection tube
(L2)
Lead wire length
Lead wire
termination
Thermocouple type
Diameter of protection tube
Length of protection tube (L1)
Length of protection tube (L2)
- - - -
Lead wire length
Lead protection
Lead wire termination
Example :T-85-10-200-150-R-NG-N (No lead wire)
:T-85-10-200-150-2000-EXA-Y-R-G-N (With lead wire)
Specify length by “mm” (130mm to 1,030mm)
Specify length by “mm” (150mm to 1,050mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Specify length by “mm” (100mm to 1,000mm)
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Details
Code
EXA Fiberglass with stainless steel
EXB Fiberglass
EXD PVC (polyvinyl chloride)
Operating temperature
0 to 150ºC
0 to 150ºC
-20 to +90ºC
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
•See Page7
M Metal connector (SCK-1602-P)
*1 : Other thermocouple connector :
See Page 10
Code
Code
Details
Details
R Type R (Platinum - Platinum Rhodium13%)
B Type B(Platinum - Platinum Rhodium6%)
S Type S (Platinum - Platinum Rhodium10%)
Code
NG
Details
Ungrounded
Mounting bracket
Code
C
N
Details
Fixed flange
No bracket
Specify size of flange when code is "C".
• Please contact distributors regarding other mounting bracket.
Class : class 2
* Class 1 is available. (Thermocouple type : R,S) (Please specify when you order)
Element : Single element
Maximum temperature for use
Thermocouple
type
R
S
B
Operating
temperature
for regular use
Maximum
temperature
1400ºC
1400ºC
1500ºC
1600ºC
1600ºC
1700ºC
*The lists above are operating temperature limits
for the element wire. For the protection tube,
please refer to page.58 about reference data of
protection tube.
Reference
19
Thermocouple type
Sensing junction
Mounting bracket
6.0, 8.0, 10.0, 13.0, 15.0, 17.0
Measuring junction
Specifications
22
Specify length by “mm” (100mm or more)
No need to specify in case of
without lead wire
Lead
protection
53
No lead wire
T - 85 - d - L1 - L2 - - -
- - - -
Diameter of
protection tube
Length of
protection tube
(L1)
(50)
L1
Sheathed Thermocouples : T-101S/T-111S
D1
d
L1
Filled with
Lead wire
wire
Epoxy Resin (Compensation Lead
termination
(MAX 120ºC) lead wire)
Specification
label
Serial number
label
L
40
T - 101S - d - L1 - L -
L2
Red
(+)
Black
(-)
Heat shrink
tube
φD1
0.5 to.1.6
(SUS316)
:Hemisphere
2.3 to 8.0:120°
L1
Protection
tube
Argon welding
0.5 to.1.6
:Hemisphere
2.3 to 8.0:120°
Hexagon
Crimp
Sleeve
Hexagon
Crimp
Sleeve
Filled with
Lead wire
Lead wire
Epoxy Resin (Compensation termination
(MAX 120ºC) lead wire)
Serial number
label
Specification
label
Heat shrink
tube
L
40
Protection
tube
(SUS316)
Argon welding
d
- - - -
T - 111S - d - L1 - L2 - L Diameter of protection tube
- - - -
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Lead wire termination
Mounting bracket
Length of protection tube
Example :T-101S-4.8-100-2000-EXA-Y-K-G-N
0.5 (Only for K,T type), 1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0
Length of
protection tube
Specify length by “mm” (100mm to 10,000mm)
Lead wire length
Specify length by “mm” (100mm or more)
Specify length by “mm”
(100mm or more, L1+L2=10,000mm or less)
Specify length by “mm”
(25mm or more, L1+L2=10,000mm or less)
• Length is 25mm without specification.
Lead protection
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Lead wire
termination
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Thermocouple type
Example :T-111S-4.8-100-30-2000-EXA-Y-K-G-N
Diameter of
protection tube
Thermocouple type
Red
(+)
Black
(-)
Code
EXD
EXE
EXF
Details
PVC (polyvinyl chloride)
Silicone rubber
Fluorocarbon polymers (FEP)
Operating temperature
-20 to +90ºC
-55 to +180ºC
0 to 200ºC
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Exposed * Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
* Class 1 is available (Please specify when you order)
Class : class 2
Element : Single element * Double element is available. (Diameter of protection tube : 3.2 or more)
(Please specify when you order)
D1
Specifications
Operating temperature Thermocouple Diameter of Operating temperature
Sleeve Dimension (D1)
protection tube for regular use
type
for regular use
Diameter of
0.5
600ºC
protection tube 0.5, 1.0, 1.6, 6.4, 8.0
Lead
1.0 to 2.3
650ºC
2.3, 3.2, 4.8
wire
type
K
3.2
750ºC
EXA,EXB,EXC
800ºC
4.8 to 6.4
8×40
10×40
8.0
900ºC
EXD,EXF
1.0 to 2.3
450ºC
EXE
10×40
J
3.2
650ºC
4.8 or more
750ºC
0.5
300ºC
1.0 to 2.3
300ºC
T
5
3.0 or more
350ºC
1.0 to 2.3
650ºC
40
3.2
E
750ºC
4.8 or more
800ºC
• Stainless flexible lead wire is available • Spring loaded type is available
• Fluor resin coating is available
It is avaiable to cover Fuluorine resin tube with 4.8
(Please specify when you order)
Model Code : T-101FS/T-111FS
protection tube (SUS316). Total Diameter becomes 6.0.
SUS316
Mgo
Isolation
Fuluorine
Silicone
resin tube Sleeve
rubber
(FEP)
(SUS304) tube
Lead wire
Crimp
8
Reference
6
4.8
It is also available to do coating with T-101 whose tube is
more than 3.2.
These model codes are T-101SC in this case.
3
L1
L
45
Operating temperature for regular use : 180ºC
Maximum temperature : 200ºC
• Please contact distributors regarding Fuluorine resin tube.
MAX 120ºC
Sleeve
SUS304
Compensation lead wire
(Fiberglass)
For flexible lead wire, the dimension of the sleeve is
10 x 40mm.
When 1.0 to 4.8 of the protection tube with EXB is
selected as the extention lead wire, its dimension is
8 x 40mm.
• No waterproof
Filled with
Lead wire
Epoxy Resin Spring
(Compensation
(MAX 120ºC) (SUS304) lead wire)
70
L
Dimensions for the spring loaded sleeve is as follows.
• Protection tube 1.0 to 4.8 with extension lead wire
EXA, EXB, EXC, EXD : 8 x 40mm
• Except the above: : 10 x 40mm
20
Sheathed Thermocouples : T-30S/T-35S
Protection tube
(SUS316)
120°
L1
Specification
label
Terminal head
Specification
label
120°
Serial number
label
Serial number
label
PF3/8
60
PF1/2
L1
No lead wire
T - 30S - d - L1 - - -
82
No lead wire
T - 35S - d - L1 - - -
With lead wire
T - 30S - d - L1 - L -
With lead wire
T - 35S - d - L1 - L -
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
- - - Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Example :T-30S-4.8-100-K-G-N (No lead wire)
:T-30S-4.8-100-2000-EXA-Y-K-G-N (With lead wire)
Example :T-35S-4.8-100-K-G-N (No lead wire)
:T-35S-4.8-100-2000-EXA-Y-K-G-N (With lead wire)
Diameter of
protection tube
3.2, 4.8, 6.4, 8.0
4.8, 6.4, 8.0
Length of
protection tube
Specify length by “mm” (100mm to 10,000mm)
Specify length by “mm” (100mm to 10,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
Lead
protection
Lead wire
termination
No need to specify in case of
without lead wire
Lead wire length
Thermocouple type
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
•See Page7
M Metal connector (SCK-1602-P)
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Operating temperature
-20 to +90ºC
-55 to +180ºC
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded
Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Class : class 2
* Class 1 is available (Please specify when you order)
Element : Single element * Double element is available. (Only for T-35S)
(Please specify when you order)
Operating temperature for regular use
Operating temperature
Thermocouple Diameter of
protection tube for regular use
type
Specifications
K
J
T
E
3.0 to 3.2
4.8 to 6.4
8.0
3.2
4.8 or more
3.2 or more
3.0 to 3.2
4.8 or more
750ºC
800ºC
900ºC
750ºC
800ºC
350ºC
650ºC
750ºC
• Fluor resin coating is available
Reference
6
4.8
It is avaiable to cover Fuluorine resin tube with 4.8 protection tube (SUS316). Total Diameter becomes 6.0.
It is also available to do coating with T-30S/T-35S whose tube is more than 3.2.
These model codes are T-30SC/T-35SC in this case.
3
SUS316
Mgo
Isolation
Fuluorine
resin tube
(FEP)
Example of Model Code
T-30SC-6.0-100-PDM-NG-N (No lead wire)
L1
• Please contact distributors regarding Fuluorine resin coating
Operating temperature for regular use : 180ºC
Maximum temperature : 200ºC
• Please contact distributors regarding Fuluorine resin tube.
21
Terminal head
Protection tube
(SUS316)
Argon welding
d
d
Argon welding
Specify size of mounting braket when code is
"A", "B", or "E".
Specify size of flange when code is "C".
L1
Thermocouple
Specification connector (CMP01)
label
Operating temperature:
Argon welding Protection tube Serial Clamp for
Max.120ºC
number connector
(SUS316)
label
(-)
(+)
1.6:Hemisphere
3.2, 4.8:120°
K
d
Thermocouple
connector (CMP01)
Operating temperature:
Argon welding
Clamp
for
Protection tube Serial connector Max.120ºC
number
(SUS316)
label
(-)
(+)
1.6:Hemisphere
3.2:120°
K
d
Sheathed Thermocouples : T-70S/T-75S
L1
34
T - 70S - d - L1 - - -
T - 75S - d - L1 - - -
Diameter of protection tube
Length of protection tube
Thermocouple type
Diameter of protection tube
Length of protection tube
Thermocouple type
Sensing junction
Mounting bracket
Example :T-70S-1.6-100-K2-G-N
Diameter of
protection tube
Length of
protection tube
Thermocouple type
Sensing junction
Mounting bracket
Example : T-75S-3.2-100-K1-G-N
1.6, 3.2, 4.8
1.0, 1.6, 3.2
Specify length by “mm” (100mm to 2000mm)
Code
Details
Code
Details
Code
Details
K1
K2
Type K (Chromel-Alumel) class 1
Type K (Chromel-Alumel) class 2
J1
J2
Type J (Iron-Constantan) class 1
Type J (Iron-Constantan) class 2
T1
T2
Type T (Copper-Constantan) class 1
Type T (Copper-Constantan) class 2
Code
Measuring junction
45
Details
Grounded
Ungrounded
* Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Exposed
Please contact with our distributors.
G
NG
O
Details
Code
Mounting bracket
Details
Code
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
A
B
C
Compression fitting
No bracket
E
N
Specify size of mounting braket when code is
"A", "B", or "E".
Specify size of flange when code is "C".
Class : class 1 or class 2
Element : Single element
Operating temperature for regular use
Operating temperature
Thermocouple Diameter of
protection tube for regular use
type
1.0, 1.6
3.2
4.8
1.0, 1.6
3.2
4.8
K
Specifications
J
Operating temperature
Thermocouple Diameter of
type
protection tube for regular use
650ºC
750ºC
800ºC
450ºC
650ºC
750ºC
Thermocoule connector (jack)
1.0, 1.6
3.2
4.8
T
Standard connector: (Material: Ceramic): CSC-01
operating temperature limit 900ºC
Thermocoule connector (jack)
*Sold separately
25.4
16.5
K
–
+
8
36
Thermocoule connector (jack) with lead wire
Thermocouple
connector (CMP02)
Lead wire
Clamp
Reference
*Sold separately
CSP02-
+
26
Regarding thermocouple connectors for
high-temperature use,
please contact distributors
Miniature connector: (Material: Ryton): CMR-01
operating temperature limit 220ºC
CMP02-
26
300ºC
350ºC
350ºC
(CLP-B)
*Sold separately
Terminal
Treatment
12.5
Thermocoule connector (jack) with lead wire
Thermocouple
connector (CMP02)
Serial
number
label
Lead wire
Serial
number
label
*Sold separately
Terminal
Treatment
Clamp
L
36
(CLP-A)
L
Model and suffix code for thermocoule connector (jack) with lead wire
Specifications
Model and Suffix Code
W-BL-
Type K (class 2)
K2
Type J (class 2)
J2
EXA
Fiberglass with stainless steel
EXB
Lead protection Fiberglass
EXD
PVC (polyvinyl chloride)
EXE
Silicone rubber
Thermocouple Thermocouple connector CMP02 jack (with clamp) TMA
connector
Thermocouple connector CSP02 jack (with clamp) TSA
Spade lugs for JIS standard "M3" size screw
Spade lugs for JIS standard "M4" size screw
Lead wire
Ring lugs for JIS standard "M3" size screw
termination
Ring lugs for JIS standard "M4" size screw
No terminal lugs
No terminal lugs *terminal soldered
Thermocouple
type
Y3
Y4
R3
R4
C
N
Lead wire length Specify length by "mm" (100mm each)
(unit: mm)
Please contact distributors regarding T type thermocouple.
22
Sheathed Thermocouples : T-80S/T-85S
Specification label
(Reverse side:Serial number label)
Specification label
(Reverse side:Serial number label)
120°
L1
17
43
L1
With lead wire
T - 80S - d - L1 - L -
With lead wire
T - 85S - d - L1 - L -
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Diameter of
protection tube
3.2, 4.8, 6.4, 8.0
Length of
protection tube
Specify length by “mm” (100mm to 10,000mm)
Lead wire length
Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Example :T-85S-4.8-100-K-G-N (No lead wire)
:T-85S-4.8-100-2000-EXA-Y-K-G-N (With lead wire)
Specify length by “mm” (100mm or more)
4.8, 6.4, 8.0
No need to specify in case of
without lead wire
• Please contact distributors regarding other length.
Thermocouple type
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
•See Page7
M Metal connector (SCK-1602-P)
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Operating temperature
-20 to +90ºC
-55 to +180ºC
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded
Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting braket when code is
"A", "B", or "E".
Specify size of flange when code is "C".
• Please contact distributors regarding other mounting bracket.
Class : class 2
* Class 1 is available (Please specify when you order)
Element : Single element
Class : class 2
* Class 1 is available (Please specify when you order)
Element : Single element
Operating temperature for regular use
Operating temperature for regular use
Operating temperature
Thermocouple Diameter of
protection tube for regular use
type
K
Specifications
J
T
E
Reference
23
22
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Example :T-80S-4.8-100-K-G-N (No lead wire)
:T-80S-4.8-100-2000-EXA-Y-K-G-N (With lead wire)
Lead wire
termination
53
No lead wire
T - 85S - d - L1 - - -
No lead wire
T - 80S - d - L1 - - -
Lead
protection
70
120°
43
d
Argon welding
d
Protection tube
Terminal
(SUS316)
head
Argon welding
Protection tube Terminal
(SUS316)
head
3.2
4.8 to 6.4
8.0
3.2
4.8 or more
3.2 or more
3.0 to 3.2
4.8 or more
750ºC
800ºC
900ºC
650ºC
750ºC
350ºC
750ºC
800ºC
Operating temperature
Thermocouple Diameter of
protection tube for regular use
type
K
J
T
E
4.8, 6.4
8.0
4.8 to 8.0
4.8 to 8.0
4.8 to 8.0
800ºC
900ºC
750ºC
350ºC
800ºC
Sheathed Thermocouples : T-90S
Serial
number
label
d
Argon welding
Protection tube
(SUS316)
Adapter
(SCK-1602-A)
Plug
(SCK-1602-P)
1.6:Hemisphere
3.2 to 8.0:120°
43
L1
42
No lead wire
T - 90S - d - L1 - - With lead wire
T - 90S - d - L1 - L -
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Example :T-90S-4.8-100-K-G-N (No lead wire)
:T-90S-4.8-100-2000-EXA-Y-K-G-N (With lead wire)
Lead
protection
Lead wire
termination
No need to specify in case of
without lead wire
Diameter of
protection tube
Length of
protection tube
Lead wire length
Thermocouple type
1.6, 3.2, 4.8, 6.4, 8.0
Specify length by “mm” (100mm to 10,000mm)
Specify length by “mm” (100mm or more)
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Operating temperature
-20 to +90ºC
-55 to +180ºC
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
E
Type E (Chromel-Constantan)
Measuring junction
Code
G
NG
O
Details
Grounded
Ungrounded
type is available depending on specification such as shapes, environment of usage, etc.
Exposed * * Exposed-junction
Please contact with our distributors.
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Specify size of mounting braket when code is
"A", "B", or "E".
Specify size of flange when code is "C".
* Class 1 is available (Please specify when you order)
* Double element is available. (Diameter of protection tube : 3.2 or more)
(Please specify when you order)
Operating temperature for regular use
Class : class 2
Element : Single element
Operating temperature
Thermocouple Diameter of
protection tube for regular use
type
1.6
3.2
4.8, 6.4
8.0
1.6
3.2
4.8 or more
1.6
3.2 or more
1.6
3.2
4.8 or more
K
Specifications
J
T
E
650ºC
750ºC
800ºC
900ºC
450ºC
650ºC
750ºC
300ºC
350ºC
650ºC
750ºC
800ºC
Connector
Pin No.
Double Element
Single Element
2 1
Reference
SCK-1602-
Pin No. Details
1
2
4
3
1
2
SCK-1604-
Pin No. Details
1
2
3
4
For connector for T-90S, Connector manufactured by Sanwa Connector Laboratory Co., Ltd. is used as standard.
Nanaboshi Electric Mfg brand is also available (Please specify when you order).
Please specify in case of no need of the plug.
24
Nicrobell Sheathed Thermocouples
Nicrobell Sheathed Thermocouple
Wires of traditional metallic sheath (stainless steel, inconel, etc) is likely to
receive chemical erosion or metallic fatigue under high temperature
circumstance, and these give negative effects on their stability and longevity.
Nicrobell Sheath is an epoch making heat resistant alloy and has chemical
composition very close to that of the type N (Nicrosil) element, minimizing
chemical erosion and metal fatigue.
Nicrobell Sheathed N Thermocouple
Magnesium Oxide
Nicrobell Sheath
Nicrobell Sheathed K Thermocouple
High Stability
Nicrobell sheath has chemical composition very close to that of the
type N element and does not generate any metal gas in high
temperature range different from conventional alloys such as stainless
steel (SUS316, SUS310) and Inconel, thus prevents the element of type
N thermocouple from contamination.
High Accuracy
Our Nicrobell sheath (N) thermocouple is class 1. It is capable of high
temperature measurement with high accuracy compared with traditional
sheath types.
Moreover, its high stability shows the same or higher realization with
PL II (platinum II) and R around 1200°C.
Because Nicrobell sheath is a nickel based alloy as K type, it minimizes
corrosion by metallic gas expansion to its wires under high temperature
range, and improves stability, environmental resistance, and thermal
resistance of its thermoelectromotive force.
Low Cost
Nicrobell K thermocouple realizes high stability and environmental
resistance with almost same price with traditional Inconel sheath.
Progress of basic function results in low cost due to long-term use by
stabilizing accuracy of thermoelectromotive force in long-term and by
extending periodic replacement by reinforcing K type strength (thermal
resistance) in high temperature range.
Improved Reliability
Traditionally, when talking about environmental resistance for selection
of thermocouple metallic sheath, people were likely to more focus on its
materials and did not pay much attention on relationship between its
materials and wire.
Nicrobell sheath is a new created metallic sheath balancing its
traditional matter, thus its accountability will be highly progressed
Environmental Resistance
Nicrobell sheath (N) thermocouple has chemical
composition very close to that of the type N element t
and does not generate any metal gas in high
temperature range different from conventional
alloys such as stainless steel (316SS, 310SS) and
Inconel, thus prevents the element of type N
thermocouple from contamination.
Thermocouple
Element
d
D
t : More than 10% of D
d : More than 18% of D
Long Life
Nicrobell sheath K type thermocouple can be used for long duration of
time in a high temperature range by the difference of performance and
traditional thick wire.
Long Life
Nicrobell sheath (N) thermocouple, which has high stability and
environmental resistance, has a longer cycle of periodic replacement
and economical for it will less change over the time and has a long life
span compared with traditional sheathes.
Terminal head type
Sleeve type
T-101N
T-30N
T-111N
Terminal head type
T-35N
25
NICROBELL Sheathed Thermocouples : T-101N/T-111N
Filled with
Lead wire
Lead wire
Epoxy Resin (Compensation termination
(MAX 120ºC) lead wire)
Specification
label
40
Hexagon
Crimp
Sleeve
D1
Serial number
Heat shrink
label
tube
L
L1
Red
(+)
Black
(-)
L2
1.0 to.1.6
:Hemisphere
3.2 to 8.0:120°
d
D1
Protection
Argon welding
tube
(NICROBELL)
1.0 to.1.6
:Hemisphere
Hexagon Sleeve
3.2 to 8.0:120°
Crimp
Filled with
Lead wire
Epoxy Resin (Compensation
(MAX 120ºC) lead wire)
Serial number
label
Specification
label
Lead wire
termination
Heat shrink
tube
Red
(+)
Black
(-)
L
40
Protection tube
(NICROBELL)
Argon welding
d
T - 101N - d - L1 - L -
- - - -
T - 111N - d - L1 - L2 - L -
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead protection
Mounting bracket
- - - -
Diameter of protection tube
Lead wire termination
Length of protection tube
Example :T-101N-4.8-100-2000-EXA-Y-K-G-N
Thermocouple type
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Example :T-111N-4.8-100-30-2000-EXA-Y-K-G-N
Diameter of
protection tube
1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0
Length of
protection tube
Specify length by “mm” (100mm to 10,000mm)
Specify length by “mm”
(100mm or more, L1+L2=10,000mm or less)
Specify length by “mm”
(25mm or more, L1+L2=10,000mm or less)
• Length is 25mm without specification.
Lead wire length
Specify length by “mm” (100mm or more)
Lead protection
Operating temperature Code
Operating temperature
Details
Details
Code
EXA Fiberglass with stainless steel
EXD PVC (polyvinyl chloride)
0 to 150ºC
-20 to +90ºC
EXB Fiberglass
EXE Silicone rubber (Only for Type K)
0 to 150ºC
-55 to +180ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
EXF Fluorocarbon polymers (FEP) (Only for Type K)
0 to 200ºC
Lead wire
termination
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) (Only for Type K)
No terminal lugs *terminal soldered
N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
*1 : Other thermocouple connector :
See Page 10
Thermocouple type
Measuring junction
Mounting bracket
Code
Details
K Type K (Chromel-Alumel)
N Type N (Nicrosil-Nisil)
Code
G
NG
Details
Grounded
Ungrounded
Code
A
B
Details
Fixed nipple (nut)
Rotary nipple (nut)
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting braket when code is
"A", "B", or "E". (See Page 6)
• Fixed nipple/Rotary nipple is Silver brazing. (Maximum temperature : 500ºC.)
• Please contact distributors regarding other mounting bracket.
Operating temperature
Thermocouple Diameter of
protection tube for regular use
type
Specifications
1.0
1.6, 2.3
3.2, 4.8
6.4
8.0
1.6, 2.3
3.2, 4.8
6.4
8.0
K
N
900ºC
1000ºC
1100ºC
1150ºC
1200ºC
1000ºC
1100ºC
1150ºC
1200ºC
• Stainless flexible lead wire is available
Model Code : T-101FS/T-111FS
SUS304
Diameter of
protection tube 1.0, 1.6, 2.3 6.4, 8.0
Lead
3.2, 4.8
wire type
EXA,EXB,EXC
EXD,EXF
EXE
8×40
10×40
10×40
5
40
• Spring loaded type is available
(Please specify when you order)
Filled with
Lead wire
Epoxy Resin Spring
(Compensation
Sleeve (MAX 120ºC) (SUS304) lead wire)
MAX 120ºC
Reference
Sleeve Dimension (D1)
D1
Class : class 1
Element : Single element
Operating temperature for regular use
Compensation lead wire
(Fiberglass)
For flexible lead wire, the dimension of the sleeve is
10 x 40mm.
When 1.0 to 4.8 of the protection tube with EXB is
selected as the extention lead wire, its dimension is
8 x 40mm.
70
L
Dimensions for the spring loaded sleeve is as follows.
• Protection tube 1.0 to 4.8 with extension lead wire
EXA, EXB, EXC, EXD : 8 x 40mm
• Except the above: : 10 x 40mm
• No waterproof
26
NICROBELL Sheathed Thermocouples : T-30N/T-35N
Terminal head
Protection tube
(NICROBELL)
120°
L1
Specification
label
60
PF3/8
PF1/2
L1
82
No lead wire
T - 35N - d - L1 - - With lead wire
T - 35N - d - L1 - L -
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
120°
Terminal head
Protection tube Serial number
(NICROBELL) label
Specification
label
Serial number
label
No lead wire
T - 30N - d - L1 - - With lead wire
T - 30N - d - L1 - L -
Argon welding
d
d
Argon welding
Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Example :T-30N-4.8-100-K-G-N (No lead wire)
:T-30N-4.8-100-2000-EXA-Y-K-G-N (With lead wire)
- - - Lead wire termination
Thermocouple type
Sensing junction
Mounting bracket
Example :T-30N-4.8-100-K-G-N (No lead wire)
:T-30N-4.8-100-2000-EXA-Y-K-G-N (With lead wire)
3.2, 4.8, 6.4, 8.0
4.8, 6.4, 8.0
Length of
protection tube
Specify length by “mm” (100mm to 10,000mm)
Specify length by “mm” (100mm to 10,000mm)
Lead wire length
Specify length by “mm” (100mm or more)
Lead
protection
Operating temperature Code
Operating temperature
Details
Details
Code
EXA Fiberglass with stainless steel
EXD PVC (polyvinyl chloride)
0 to 150ºC
-20 to +90ºC
EXB Fiberglass
EXE Silicone rubber (Only for Type K)
0 to 150ºC
-55 to +180ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Lead wire
termination
No need to specify in case of
without lead wire
Diameter of
protection tube
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
•See Page7
M Metal connector (SCK-1602-P)
*1 : Other thermocouple connector :
See Page 10
Thermocouple type
Measuring junction
Mounting bracket
Code
Details
K Type K (Chromel-Alumel)
N Type N (Nicrosil-Nisil)
Code
G
NG
Details
Grounded
Ungrounded
Code
A
B
Details
Fixed nipple (nut)
Rotary nipple (nut)
Code
E
N
Details
Compression fitting
No bracket
• Fixed nipple/Rotary nipple is Silver soldering. (Maximum temperature : 500ºC.)
• Please contact distributors regarding other mounting bracket.
Class : class 1
Element : Single element
Operating temperature for regular use
Specifications
Operating temperature
Thermocouple Diameter of
protection tube for regular use
type
K
N
Reference
27
3.2 to 4.8
6.4
8.0
3.2 to 4.8
6.4
8.0
1100ºC
1150ºC
1200ºC
1100ºC
1150ºC
1200ºC
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Temperature sensors for various applications
Bayonet Type
Bayonet Type
The tip is going to be pressure welded to the measured object by mounting
bracket.
Suitable for measurement of hot runners, dies and moulds.
(Variable insertion length type)
Thermocouple with bayonet. Length can be easily adjusted.
Easy mounting is possible by moving the bayonet cap dependent upon the
insertion length.
T-221
Spring loaded type
T-200
Screwed Tip Type
T-210
The tip is M6 size (M8 size is also available) rotary screw. Internal screws will
be threaded in the fitting point.
*M6, M8 is based on JIS Standard.
T-230
Fixing Screw Type for Surface Temperature
Fix the sensor at a 4.5 fixed screw hole of the tip with a screw.
Suitable for temperature measurement for the tiny spaces.
Sleeve type
T-201
T-201S (Sheathed type)
T-240
T-211
T-211S (Sheathed type)
Ring Type for Surface Temperature
Suitable for temperature measurement for the pipe shaped objects
and the surface of the nozzles.
T-250
For Resin Temperature
Sheathed Thermocouple for High Temperature (550°C)
T-202SH
Capable of measurement of the molten resin temperature, such as the inside
of the extruder. M16 screw is cut and its tip directly touches to the melting
resin.
T-260
Withstand pressure : 70MPa (at 250ºC)
T-212SH
For Resin Temperature
Bayonet Type
(Variable insertion length type)
Thermocouple with bayonet. Length can be easily adjusted.
Decide the position of the mounting bracket dependent upon insertion length
and fix the spring by fixed screw.
By utilizing ZHF (zero-heat-flow) method, it eliminates thermal disturbances and
temperature errors between the tip and the outside case and realizes more precise
temperature measurement of the melting resin.
T-270Z
Withstand pressure : 100MPa (at 250ºC)
T-220
28
L2
25
17
Silver
Silver
Spring(SUS304)
soldering
soldering
Protection
Lead wire
Spring
tube
Bayonet
(SUS304) (Compensation Lead wire
(SUS304)
termination
Sleeve
lead wire)
20
2
L
20
50
K:180
T,J:150
L
7
120°
L1
L1
K:180
T,J:150
Lead wire
Lead wire
termination
(Compensation
lead wire)
Spring
(SUS304)
Bayonet
Spring(SUS304)
Silver soldering
2
10
7
50
120°
Sleeve
10
d
Bayonet Type Thermocouples : T-200/T-210
Protection tube
(SUS304)
Silver soldering
d
T - 200 - d - L1 - L -
T - 210 - d - L1 - L -
- - - -
- - - -
Diameter of protection tube
Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Example :T-210-5-100-2000-EXA-Y-K-G-N
Example :T-200-5-100-2000-EXA-Y-K-G-N
Diameter of
protection tube
5.0
Length of
protection tube
Specify length by “mm” (50mm to 1,000mm)
Lead wire length
Lead protection
Lead wire
termination
Thermocouple type
Specify length by “mm” (50mm to 1,000mm)
• Please contact distributors regarding other length.
• L2 is 25mm. Other length is available. (Please specify when you order)
• Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
Details
Fiberglass with stainless steel
Fiberglass
Code
EXA
EXB
Operating temperature
0 to 150ºC
0 to 150ºC
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
Measuring junction
Code
G
NG
Details
Grounded
Ungrounded
Mounting bracket
Code
Details
Holder (Specify screw type and length. See Reference.)
G
No bracket
N
Class : class 2
Spring press bonding
* Class 1 is available (Please specify when you order)
Element : Single element * Double element is available (Please specify when you order)
Maximum temperature for use
Thermocouple
type
Operating temperature
for regular use
Maximum
temperature
300ºC
300ºC
200ºC
400ºC
400ºC
250ºC
K
J
T
50
Holder
• Stainless flexible lead wire is available
Model Code : T-200F/T-210F
4
3
For diameter 6 protection tube, thermocouple holder is a special type.
Please contact distributors.
Bayonet
2
L
3
Screw:R(PT)1/8
L=32,40,62
• Other screw type is available
8.5
9
d
10
14
12.8
29
4
10
(Specify by ordering)
SUS304
Pin (3)
12
+0.2
0
7.2
• Diameter 6 protection tube is available.
3.5
Reference
Compensation lead wire (Fiberglass)
3
R (PT)1/8
SUS304
• No waterproof
6
* Spring compression :
10 to 20mm
• Install bayonet so that its amount of spring
compression should be 10mm to 20mm.
12
Specifications
Bayonet Type Thermocouples : T-201/T-211
Hexagon
25 Crimp
Filled with
Sleeve
(L2)
(SUS304) Epoxy Resin
Protection
tube
(SUS304)
Hexagon
Argon
Crimp
Silver
welding
Filled with
Lead wire
soldering Bayonet Sleeve
Lead wire
(SUS304) Epoxy Resin (Compensation
Spring
termination
(MAX 120ºC) lead wire)
D1
17
(MAX 120ºC)
Specification
label
50
Heat shrink
tube
L
7
Protection tube
(SUS304)
Argon welding
120°
L1
T - 201 - d - L1 - L -
Serial number
label
40
Bayonet
Spring
Silver soldering
Heat shrink
tube
L
40
50
L1
Serial number
label
Specification
label
Red
(+)
Black
(-)
d
- - - -
T - 211 - d - L1 - L -
- - - -
Diameter of protection tube
Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Example :T-201-5-100-2000-EXA-Y-K-G-G
Example :T-211-5-100-2000-EXA-Y-K-G-G
Diameter of
protection tube
5.0
Length of
protection tube
Specify length by “mm” (50mm to 1,000mm)
Specify length by “mm” (50mm to 1,000mm)
• Please contact distributors regarding other length.
• L2 is 25mm. Other length is available. (Please specify when you order)
• Please contact distributors regarding other length.
Lead wire length
Specify length by “mm” (100mm or more)
Lead protection
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Thermocouple type
Measuring junction
Mounting bracket
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Code
G
NG
Details
Grounded
Ungrounded
Code
G
N
Details
Holder (Specify screw type and length. See Reference.)
No bracket
Maximum temperature for use
Thermocouple
type
Operating temperature
for regular use
Maximum
temperature
300ºC
300ºC
200ºC
400ºC
400ºC
250ºC
K
J
T
Sleeve Dimension (D1)
50
* Spring compression :
10 to 20mm
• Install bayonet so that its amount of spring
compression should be 10mm to 20mm.
5
40
4
Model Code : T-201F/T-211F
3
+0.2
0
2
7.2
Compensation lead wire (Fiberglass)
• No waterproof
3
R (PT)1/8
SUS304
10
• Diameter 6 protection tube is available.
L
For diameter 6 protection tube, thermocouple holder is a special type.
Please contact distributors.
4
Screw:R(PT)1/8
L=32,40,62
• Other screw type is available
8.5
9
d
10
14
12.8
Pin (3)
12
3
(Specify by ordering)
SUS304
3.5
Bayonet
Lead wire type D1
EXA,EXB,EXC 8
EXD,EXF
EXE
10
Holder
• Stainless flexible lead wire is available
Reference
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
Spring press bonding
Class : class 2
* Class 1 is available (Please specify when you order)
Element : Single element
* Double element is available (Please specify when you order)
Specifications
Operating temperature
-20 to +90ºC
-55 to +180ºC
0 to 200ºC
Details
PVC (polyvinyl chloride)
Silicone rubber
Fluorocarbon polymers (FEP)
12
Lead wire
termination
Code
EXD
EXE
EXF
D1
2
Red
(+)
Black
(-)
2
D1
7
d
120°
Lead wire
Lead wire
(Compensation termination
lead wire)
6
30
Bayonet Type Sheathed Thermocouples : T-201S/T-211S
D1
17
Sleeve
④
(SUS304)
Silver
⑤
soldering Bayonet
Filled with Lead wire
(Compensation Lead wire
Epoxy
Resin
Hexagon
Spring
lead wire)
termination
Crimp
(MAX 120ºC)
50
40
Heat shrink
tube
T - 201S - d - L1 - L -
50
Bayonet
Spring
Silver soldering
*1
2
*1
5(d=3.2)
7(d=4.8)
Heat shrink
tube
③L
*1
5(d=3.2)
7(d=4.8)
Protection tube
(SUS316)
Argon welding
① d
- - - -
T - 211S - d - L1 - L -
- - - -
Diameter of protection tube
Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Thermocouple type
Length of protection tube
Thermocouple type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Example :T-201S-4.8-100-2000-EXA-Y-K-G-G
Example :T-211S-4.8-100-2000-EXA-Y-K-G-G
①
Diameter of
protection tube
3.2, 4.8
②
Length of
protection tube
Specify length by “mm” (50mm to 1,000mm)
Specify length by “mm” (50mm to 1,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
• L2 is 25mm. Other length is available. (Please specify when you order)
③
Lead wire length
④
⑤
Lead protection
Lead wire
termination
⑥ Thermocouple type
⑦ Measuring junction
⑧ Mounting bracket
Specify length by “mm” (100mm or more)
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
EXF
Details
PVC (polyvinyl chloride)
Silicone rubber
Fluorocarbon polymers (FEP)
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Code
G
NG
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
Details
Grounded
Ungrounded
Code
G
N
Details
Holder (Specify screw type and length. See Reference.)
No bracket
Class : class 2
Spring press bonding
* Class 1 is available (Please specify when you order)
Element : Single element
* Double element is available (Please specify when you order)
Maximum temperature for use
Specifications
Operating temperature
-20 to +90ºC
-55 to +180ºC
0 to 200ºC
Operating temperature
for regular use
Thermocouple
type
K
J
T
400ºC
400ºC
250ºC
Sleeve Dimension (D1)
Lead wire type D1
EXA,EXB,EXC 8
EXD,EXF
EXE
10
* Spring compression :
50
10 to 20mm
• Install bayonet so that its amount of spring
compression should be 10mm to 20mm.
5
In case of selecting silicon cover (code:EXE),
temperature range for usage changes to 180ºC.
• Stainless flexible lead wire is available
40
Holder
Model Code : T-201FS/T-211FS
4
3
Reference
L
d
10
4
Diameter of protection tube : 3.2, d=5.2mm
Diameter of protection tube : 4.8, d=7.2mm
Screw:R(PT)1/8
L=32,40,62
(Specify by ordering)
• Other screw type is available
9
8.5
6
3
SUS304
14
12.8
Pin (3)
3.5
12
12
2
10
Bayonet
31
d 0
Compensation lead wire (Fiberglass)
SUS304
• No waterproof
+0.2
3
R (PT)1/8
D1
② L1
Serial number
label
③L
Specification
label
(+)
Black
(-)
Specification Serial number
label
label
40
120°
2
Red
(+)
Black
(-)
② L1
120°
D1
①
*1
d
Argon welding
Protection
tube
(SUS316)
Hexagon
④
⑤
Crimp Sleeve
Lead wire
Lead wire
Filled with
(Compensation
termination
(SUS304) Epoxy Resin
lead wire)
(MAX 120ºC)
Red
25
(L2)
Bayonet Type Sheathed Thermocouples : T-202SH/T-212SH (For High Temperature)
*2
5 to 25
8
5 to 25
11
*2
2.3
*2
L3 *1
40
L
T - 202SH - d - L1 - L -
- -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
S
- - L2
Lead wire termination
8
Lead wire termination
Thermocouple type
Sensing junction
S : 25mm
L2 : More than 25mm (Specify length by “mm”)
2.3, 4.8
Specify length by “mm” (1000mm to 8000mm)
Details
Fiberglass with stainless steel
Fiberglass
Operating temperature
0 to 150ºC
0 to 150ºC
Lead wire
termination
Code
Details
Y3
Spade lugs for JIS standard "M3" size screw
R3
Ring lugs for JIS standard "M3" size screw
MS1 Metal connector (SCK-1602-P)
MN1 Metal connector (NCS-162-P-CH)
MN2 Metal connector (NCS-162-AdF-CH)
MN3 Metal connector (NCS-162-PM-CH)
Thermocouple type
Code
K1
K2
Details
Type K (Chromel-Alumel) Class 1
Type K (Chromel-Alumel) Class 2
Measuring junction
Code
G
NG
Details
Grounded
Ungrounded
T-202SH
Code
S
91 to
Details
90mm
More than 90mm
(Specify length by “mm”)
• L2 should be within L1+L2=500mm. (Maximum)
Code
TS1
TS2
TS3
TM1
TM2
TM3
N
T-212SH
Code
S
26 to
Details
Thermocouple connector (CSP01+CLP-A)
Thermocouple connector (CSP01)
Thermocouple connector (CSP01+CLP-A+CSP03)
Thermocouple connector (CMP01+CLP-B)
Thermocouple connector (CMP01)
Thermocouple connector (CMP01+CLP-B+CMP03)
No terminal lugs *terminal soldered
Details
!
25mm
If temperature of the sleeve may
More than 26mm
exceed 150ºC, make the L2 longer
(Specify length by “mm”)
and insulate the sleeve.
• L2 should be within L1+L2+80=500mm. (Maximum)
Class : class 2 * Class 1 is available (Please specify when you order)
Element : Single element
Operating temperature for regular use : 550ºC
4
2
5.2
Bayonet
L
12
3
3
+0.2
0
*1:
Holder
L3= holder length (excluding screw) + mounting hole length.
More than 60 mm is recommended.
R (PT)1/8
*2:
Bayonet cap should be fit to the holder in the range of 5 to 25 mm.
6~8mm is recommended as the amount of spring compression.
(The gap between the pin holder and the bayonet
10
should be 0 to 2 mm for setting.)
3
Screw:R(PT)1/8
L=32,40,62
(Specify by ordering)
16
Reference
S
- - L2
Specify length by “mm” (25mm to 500mm)
Code
EXA
EXB
Specifications
- -
Example :T-212SH-4.8-25-EXA-Y3-K2-G-30
Lead protection
Length of L2
Protection tube (SUS304)
4.8
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Thermocouple type
Sensing junction
S : 90mm
L2 : More than 90mm (Specify length by “mm”)
L
Hexagon Crimp
120°
T - 212SH - d - L1 - L -
Example :T-202SH-4.8-25-EXA-Y3-K2-G-S
Diameter of
protection tube
Length of
protection tube
Lead wire length
(50)
40
Bayonet
(Stainless Steel)
Spring
(MAX 550ºC)
80
(50)
Sleeve
Lead wire
Lead wire
Spring
(Stainless
(Compensation termination
Steel)
(SUS304) lead wire)
(MAX 150ºC)
2.3
L1
L1
2.3
*2
5 to 25
L2=90
120°
Sleeve
Diameter of
(Stainless
protection tube : 4.8 L2=20
Lead wire
Spring (Compensation Lead wire
Steel)
termination
(MAX 150ºC) (SUS304) lead wire)
8
120°
Spring
(MAX 550ºC)
Protection tube (SUS304)
11
4.8
Diameter of protection tube : 4.8
Protection tube
(SUS304)
Bayonet
Spring
(Stainless
(MAX 550ºC) Steel)
Hexagon
Crimp(7)
L3 *1
L
40
L
Bayonet
(Stainless Steel)
5 to 25
L2=90
(50)
40
80
Red
(+)
Black
(-)
(50)
Sleeve
Lead wire
Spring
(Stainless
Lead wire
termination
(SUS304) (Compensation
Steel)
(MAX 150ºC)
lead wire)
L2=20
L1
L3 *1
L1
Sleeve
(Stainless
Lead wire
Steel)
Spring (Compensation Lead wire
termination
(MAX 150ºC) (SUS304) lead wire)
8
120°
Diameter of
protection tube : 2.3
L3 *1
2.3
Diameter of protection tube : 2.3
Protection tube
(SUS304)
Bayonet
Spring
(Stainless
(MAX 550ºC) Steel)
• Other screw type is available
16
32
Silver
soldering Protection
tube
(SUS304)
4.8
Element wire
(Fiberglass with stainless steel)
Spring
(SUS304)
Bayonet
Spring Lock
120°
Lock screw: M4 x 8
25
Lead wire
termination
Serial number Heat shrink
label
tube
80
4.8
Bayonet Type Thermocouples : T-220/T-221
Brass
(Ni-3 Plating)
Element wire
(Fiberglass with
stainless steel)
Bayonet
Spring
Crimp
15
200
Serial number
label
L
L
T - 220 - L - EXA - -
T - 221 - L - EXA - -
Heat shrink
tube
Lead wire length
Lead wire length
Lead protection : EXA, Element wire (Fiberglass with stainless steel)
Lead protection : EXA, Element wire (Fiberglass with stainless steel)
Lead wire termination
Lead wire termination
Thermocouple type
Thermocouple type
Example :T-220-2000-EXA-Y-K
Lead wire length
Example :T-221-2000-EXA-Y-K
Specify length by “mm” (500mm to 10,000mm)
Details
Code
Lead protection
Lead wire
termination
EXA
Details
Spade lugs for JIS standard "M3" size screw
Ring lugs for JIS standard "M4" size screw
Metal connector (SCK-1602-P)
Thermocouple connector (CSP01+CLP-A+CSP02)
No terminal lugs *terminal soldered
Code
Y
R
M
TE *1
N
Details
Code
Element wire
(Fiberglass with stainless steel) (1.0/1X2)
EXA
Element wire
(Fiberglass with stainless steel) (0.65/1X2)
Code
Y
R
N
Details
Spade lugs for JIS standard "M3" size screw
Ring lugs for JIS standard "M4" size screw
No terminal lugs *terminal soldered
• See Page 7.
• See Page 7.
*1 : Other thermocouple connector : See Page 10
Thermocouple type
Code
K
J
T
Code
K
J
Details
Type K (Chromel-Alumel)
Type J (Iron-Constantan)
Type T (Copper-Constantan)
Class : class 2
* Class 1 is available (Please specify when you order)
Element : Single element
Details
Type K (Chromel-Alumel)
Type J (Iron-Constantan)
Class : class 2
Element : Single element
* Double element is available (Please specify when you order)
* Double element is available (Please specify when you order)
Measuring junction : Grounded
Measuring junction : Grounded
* Grounded type is available (Please specify when you order)
Maximum temperature for use
Maximum
temperature
300ºC
300ºC
200ºC
400ºC
400ºC
250ºC
K
J
T
Bayonet
Maximum temperature for use
Operating temperature
for regular use
Thermocouple
type
14
d
10
14
12.8
3.5
300ºC
300ºC
400ºC
400ºC
Bayonet
SUS303
4
12
Maximum
temperature
K
J
SUS304
Pin (3)
Operating temperature
for regular use
12.6
Thermocouple
type
4
12
8.5
8.5
Reference
8
9
Pin (3)
3.5
Specifications
6
5.5
Holder
4
3
Screw:R(PT)1/8
L=32,40,62
2
10
L
3
12
5.2
+0.2
0
3
R (PT)1/8
33
Lead wire
termination
(Specify by ordering)
• Other screw type is available
3
10 4 10
Serial number
label
60
5
Heat shrink
tube
Lead wire
(Element
wire)
Lead wire
termination
20
40
Serial number
label
Heat shrink
tube
L
20
2
L
4.5
5
Spring
(SUS304)
Nut : 10
Lead wire
termination
Lead wire
(Element
wire)
Spring
Silver
soldering (SUS304)
8
Loose screw
M6:P1(SUS304)
4
Screwed Tip Thermocouples : T-230
Fixing Screw Type Thermocouples for
Surface Temperature Measurement : T-240
Brass
T - 230 - L -
- -
T - 240 - L -
Lead wire length
Lead wire length
Lead protection
Lead protection
Lead wire termination
Lead wire termination
Thermocouple type
Thermocouple type
Example :T-230-2000-EXA-Y-K
Example :T-240-2000-EXA-Y-K
Lead wire length
Specify length by “mm” (500mm to 10,000mm)
Lead protection
Code
Details
EXA Element wire (Fiberglass with stainless steel) (0.3/7X2)
EXB Element wire (Fiberglass) (0.3/7X2)
EXE Element wire [PVC (polyvinyl chloride) with copper wire braided] (0.1/30X2)
* EXE type is Thermocouple K only.(Protection : Black, Flat type)
Lead wire
termination
Thermocouple type
- -
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
*1 : Other thermocouple connector :
See Page 10
Code
Details
Type T (Copper-Constantan)
T
Class : class 2 * Class 1 is available (Please specify when you order)
Element : Single element
Measuring junction : Grounded
Maximum temperature for use
Specifications
Thermocouple
type
K
J
T
Operating temperature
for regular use
Maximum
temperature
300ºC
300ºC
200ºC
400ºC
400ºC
250ºC
In case of selecting silicon cover (code:EXE),
temperature range for usage change to 180ºC.
Screw Type
Reference
Standard M6:P1
M8:P1.25
Optional
W1/4
(Please specify when you order)
34
Ring Type Thermocouples for Surface Temperature Measurement : T-250
Silver
soldering
d
Lead wire
(Element wire)
40
5
Silver
soldering
15°
M3×8
L
25
Tube
SUS304
Spring
SUS304
4
1
Heat shrink
tube
Serial number
label
Lead wire
termination
Hexagon 5 5
5 nut
*1
T - 250 - d - L -
- -
Diameter of ring
Lead wire length
Lead protection
Lead wire termination
Thermocouple type
Example :T-250-50-2000-EXA-Y-K
Diameter of
Specify length by “mm” (25mm to 150mm) (Standard : 30, 35, 40, 45, 50, 55, 60, 65)
ring
Lead wire length Specify length by “mm” (500mm to 10,000mm)
Lead protection
Lead wire
termination
Thermocouple
type
Code
EXA
EXB
Details
Element wire (Fiberglass with stainless steel) (0.3/7X2)
Element wire (Fiberglass) (0.3/7X2)
Code
Details
Code
Details
Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02)
N
No terminal lugs *terminal soldered
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
•See Page7
Code
Details
K Type K (Chromel-Alumel)
J Type J (Iron-Constantan)
Code
Details
Type T (Copper-Constantan)
T
Class : class 2
* Class 1 is available (Please specify when you order)
Element : Single element
Measuring junction : Grounded
Maximum temperature for use
Specifications
Thermocouple
type
K
J
T
Reference
35
Operating temperature
for regular use
Maximum
temperature
300ºC
300ºC
200ºC
400ºC
400ºC
250ºC
*1 : Ring width 7mm or 10mm are also available
Width of Ring Lock screw size
*1
5mm
M3X8
Standard
7mm
M4X8
Optional
10mm
M4X8
*1 : Other thermocouple connector :
See Page 10
Thermocouples for Resin Temperature : T-260/T-270Z
70
20±0.5
Lead wire
(Compensation
lead wire)
30
15
5
M16 P:1.5
Silver soldering
23×26
SUS304 Thermocouple connector
(SUS304)
(CSP01)
90°
8 5
13
19
115
Thermocouple connector
(CSP02)
4.8 ±0.05
5
8 5
6±0.5
SUS316
MgO insulation
Silicon resin
14 ±0.07
10 ±0.07
M16 P:1.5
Silicon resin
26×30 Silver soldering
Thermocouple connector
(SUS304)
SUS304
(CSP01)
90°
14 ±0.07
10 ±0.07
5 ±0.05
Silver soldering
59
30
6±0.5
Thermocouple connector
(CSP02)
Lead wire
termination
20±0.5
Lead wire
(Compensation
lead wire)
30
15
Lead wire
termination
L
36.4
L
36.4
T - 260 - L -
- -
Lead wire length
Lead protection
Lead wire termination
Thermocouple type
T - 270Z - L Lead wire length
Lead protection
Example :T-260-2000-EXA-Y-K2
Lead wire length
Lead protection
Lead wire
termination
Thermocouple type
Specifications
13
115
- Lead wire termination
Thermocouple type
Example :T-270Z-2000-EXA-Y-K2
Specify length by “mm”
Code
EXA
EXB
EXE
Details
Element wire (Fiberglass with stainless steel)
Element wire (Fiberglass)
Element wire [PVC (polyvinyl chloride) with copper wire braided] (Only for Type K)
Code
Details
Code
Details
No terminal lugs *terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1602-P)
Code
Details
K2 Type K (Chromel-Alumel)
J2 Type J (Iron-Constantan)
Class : class 2
Measuring junction : Grounded (T-260 is available for ungrounded type. Please specify when you order)
Maximum temperature for use : 400ºC
Material of protection tube : SUS304(T-260), SUS316(T-270Z)
Material body : SUS304
withstand pressure : 70MPa (T-260, at 250ºC), 100MPa (T-270Z, at 250ºC)
Select codes from the below when order lead wires only.
Mounting hole (Unit:mm)
Model and Suffix Code
W-BL-
Thermocouple
type
Type K (class 2)
K2
J2
Type J (class 2)
Fiberglass with stainless steel
EXA
Fiberglass
EXB
Lead protection
PVC (polyvinyl chloride)
EXD
EXE
Silicone rubber
Thermocouple Thermocouple connector CSP02 jack (with clamp) TSA
connector
Spade lugs for JIS standard "M3" size screw
Spade lugs for JIS standard "M4" size screw
Lead wire
Ring lugs for JIS standard "M3" size screw
termination
Ring lugs for JIS standard "M4" size screw
No terminal lugs
No terminal lugs *terminal soldered
Lead wire length Specify length by "mm" (100mm each)
(unit: mm)
±0.1
20
90°
16
Specifications
30
10.3
+0.1
+0.2
626
M16P1.5
Reference
Y3
Y4
R3
R4
C
N
Thermocouple for Resin Temperature
Accurate measurement of resin temperature was difficult in general as there are many thermal disturbances as well as high temperature
and high pressure.
T-260/T-270Z has an excellent resistance against high temperature and high pressure. Moreover, T-270Z can measure resin temperature
change even there are thermal disturbances because of its Zero-Heat-Flow structure. That leads to be stable resin temperature control.
Because the barrel temperature will be transferred to the protection tube, traditional sensors negatively effects on their measurements.
T-270Z realizes its accurate measurement of the resin temperature by compensating the barrel temperature.
Condition where resin temperature is higher than barrel temperature
Conventional sensor
T-270Z
Resin
temperature
Temperature
Barrel Tempearture
Temperature
Resin temperature
Resin temperature
Measuring temperature
Measuring temperature
Barrel temperature
Barrel temperature
Extruder
Time
Time
When the resin temperature is lower than the barrel temperature,
traditional sensors detects a slightly higher degree than the actual resin temperature.
36
Adhesive and exposed tip type temperature sensor ST-50/51
Adhesive type temperature sensor : Max. 300°C
Glass cloth base type ST-50
Sensing
point
(Adhesive point)
ST-51
Polyimide sheet type
Sensing
point
(Adhesive point)
Polyimide sheet type (Fine type)
ST-51S
Sensing
point
(Adhesive point)
Exposed tip type temperature sensor : Max. 300°C
Glass cloth base type ST-50B
Sensing
point
RK
C
ST
-50
ST-51B
Polyimide sheet type
Sensing
point
Polyimide sheet type
Glass cloth base type
ST-50
ST-50B
ST-51
ST-51S
ST-51B
Glass cloth base
Glass cloth base
6.7mm
Polyimide sheet
6.7mm
Thickness
: 0.34mm
Thickness
: 0.34mm
Thickness
: 0.15mm
Thermocouple K
element wire
107mm type : 50µm or 100µm
307mm, 507mm type : 100µm
Sensing
point
Adhesive
pasting part
Thermocouple K
element wire
100mm type : 50µm or 100µm
300mm, 500mm type : 100µm
Sensing
point
Exposed
part 4mm
7mm
6.7mm
6.7mm
Thickness
: 0.13mm
Thermocouple K
element wire
107mm type : 50µm
Sensing
point
Adhesive
pasting part
Sensing
point
7mm
2.3mm
Thickness
: 0.15mm
Thermocouple K
element wire
107mm type : 50µm
Adhesive
pasting part
7mm
Sensing
point
Thermocouple K
element wire
107mm type : 50µm
Exposed
part
4mm
4mm
Fast response
Durable adhesive tape
As the heat capacity of the sensor is very small temperature
can be measured instantly.
The adhesive tape can be repeatedly applied to and detached
from various types of surfaces.
<Durability of adhesive tape>
• Up to 150°C (302°F) : Repeated use and detachment is available.
• Up to 200°C (393°F)
When temperature stays above 150°C (302°F), repeated use
and detachment is available.
• Up to 250°C (482°F)
When temperature stays above 200°C (392°F), repeated use and
detachment is available.
• Higher than 250°C (482°F)
Adhesive part will be burnt. Repeated use is not available.
250°C
0.1sec
0°C
< ST-50 >
Measuring up to 300°C (572°F)
Up to 300°C(572°F) can be measured by the tip with an
adhesive tape.
37
Polyimide sheet
Polyimide sheet
External Dimensions
4
ST-50/ST-51
Adhesive
pasting part
Thermocouple K
element wire
ST-50 : 50μm or 100μm
ST-51 : 100μm
ST-50B/51B
Connector terminal
Thermocouple K
element wire
ST-50 : 50μm or 100μm
ST-51 : 100μm
Thickness : ST-50 : 0.34mm
ST-51 : 0.15mm
4
ST-50-300: 307mm, ST-50-500: 507mm
Thermocouple K
Adhesive
element wire
pasting part
Thickness : 0.34mm
ST-50B-300
ST-50B-500
Connector terminal
Thickness : ST-50 : 0.34mm
ST-51 : 0.15mm
ST-50B-300: 300mm, ST-50B-500: 500mm
6.7
6.7
ST-50-300
ST-50-500
100
6.7
6.7
107
Thermocouple K
element wire
100μm
Connector terminal
100μm
Connector terminal
Thickness : 0.34mm
2.3
107
40
6.7
7
ST-51S
Adhesive
Thermocouple K
pasting part element wire
Thickness
: 0.13mm
Thickness
: 0.18mm
Connector terminal
50μm
Specifications
<ST-50/ST-51/ST-51S>
ST-50/50B :
Glass cloth base sheet
ST-51/51S/51B : Polyimide sheet
-40 to 300°C (-40 to 577°F)
Operating Temperature ST-51S :
ST-50/50B/51S/51B : 0 to 300°C (32 to 577°F)
Type K
Thermocouple
ST-50/50B :
100/300/500mm Type
Sensor Length
ST-51/51S/51B : 100mm Type
ST-50/50B :
0.34mm
Sensor Thickness
ST-51/51S/51B : 0.13mm
50μm/100μm (100mm Type)
Element wire diameter ST-50/50B :
100μm (300/500mm Type)
ST-51/51S/51B : 50μm
Sheet Material
ST-51S
(50μm element wire)
ST-50/51
51Ω
±1.3°C
0.03sec
51Ω
±1.3°C
(100μm element wire)
0.08sec
17Ω
±1.5°C
ST-50-300
(100μm element wire)
0.08sec
41Ω
±1.5°C
ST-50-500
(100μm element wire)
0.08sec
66Ω
±1.5°C
ST-50B-100-D
0.03sec
17Ω
±1.5°C
ST-50B-300
(100μm element wire)
0.03sec
41Ω
±1.5°C
ST-50B-500
0.03sec
66Ω
±1.5°C
ST-50B/51B
(50μm element wire)
ST-50-100-D
PPS resin
230°C
ø3.3 Extended cable, Standard 1m
Silicon rubber coated (Green)
7.0Ω or less (1m)
180°C
Approx 20g
A
(Cable 1m, Y-sharped terminal lug type)
(Ca
(100μm element wire)
(100μm element wire)
*1 : Response when temperature of paraffin is 250°C (482°F).
*2 : Accuracy when temperature on metal surface is 100°C (212°F).
35
Cable length :
1m (Standard)
Open the slide cover.
Max. 230°C
Cable
Insert the non-adhesive edge
of the sensor.
Max. 180°C
7.5
Connector
10.6
How to connect
ST-50/ST-51 sensor
Slide cover type
connector
ø3.3
10.4
12.7
Cable Max. temperature
Weight
0.08sec
(50μm element wire)
<W-ST50A> Connector Cable for ST-50/ST-51
Connector material
Connector Max. temperature
Cable
Cable material
Resistance value
*2
Response of *1 Resistance
value
Accuracy
95.0%
(With cable 1m)
Response of Metal Surface
(Adhesive type)
±1.2°C
51Ω
0.08sec
50μm element wire type : 0.4sec
100μm element wire type : 0.9sec
Terminal
Connector for DP-700
Solder treatment type
W-ST50A-1000-N
W-ST50A-1000-6C
DP-700
Connector Cable for ST-50/ST-51
Non-treatment type
Close the slide cover.
W-ST50A-1000-C
Connector for DP-350/500
W-ST50A-1000-3C
Y-sharped lug type
Miniature-thermocouple
connector plug (CMP-01) type
W-ST50A-1000-TM1
W-ST50A-1000-Y3
Model and Suffix Code
<ST-50> Glass cloth base type
ST-50 (Adhesive type)
Contents
Model Code
Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set
ST-50
ST-50-100-D Length : 107mm, Element Wire Diameter 100μm, 5 pieces per set
Length : 307mm, Element Wire Diameter 100μm, 1 piece
ST-50-300
Length : 507mm, Element Wire Diameter 100μm, 1 piece
ST-50-500
<ST-51> Polyimide sheet type
ST-50B (Exposed tip type)
Model Code
ST-50B-100-04
ST-50B-100-04-D
ST-50B-300-04
ST-50B-500-04
Contents
Length : 104mm, Element Wire Diameter 50μm, 5 pieces per set
Length : 104mm, Element Wire Diameter 100μm, 5 pieces per set
Length : 304mm, Element Wire Diameter 100μm, 1 piece
Length : 504mm, Element Wire Diameter 100μm, 1 piece
ST-50B (Exposed tip type)
ST-51 (Adhesive type)
Model Code
ST-51-100-C
DP-350
Contents
Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set
Contents
Model Code
ST-51B-100-C Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set
<ST-51S> Polyimide sheet type
<ST-50 Connector>
ST-51S (Adhesive type)
Model Code
W-ST50A-1000-3C
W-ST50A-1000-6C
W-ST50A-1000-Y3
W-ST50A-1000-N
W-ST50A-1000-C
Contents
Model Code
ST-51S-100-C Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set
Contents
ST-50/51 Connector cable for DP-350/500 connection (1m)
ST-50/51 Connector cable for DP-700 connection (1m)
Y-sharped terminal lug type ST-50/51 Connector cable (1m)
Solder treatment type ST-50/51 Connector cable (1m)
Non-treatment type ST-50/51 Connector cable (1m)
connector plug (CMP-01) type
W-ST50A-1000-TM1 Miniature-thermocouple
ST-50/51 Connector cable
38
Temperature Sensors for Extremely Small Surface ST-55/56
Features
Measuring point on the tip
Measuring temperature in a small surface area
Fluorine resin coating type
(With adhesive tape)
A fine thermocouple enables measurement of a fine surface or a surface
with small thermal capacity such as SMT parts.
Measuring
point
Measuring up to 500 °C (932°F)
(Ceramic coating type)
Adhesive
tape
Ceramic coating type can measure up to 500°C (932°F) and fluorine
resin coating type up to 260°C (500°F).
Optional adhesive tape on the tip
Up to
260°C (500°F)
(Fluorine resin coating type)
Optional adhesive tape on the fluorine resin coating type
allows the tip to stick to an exact spot for measurement.
Ceramic coating type
Measuring
point
Fast response with fine thermocouple
As the heat capacity of the sensor is very small temperature can be
measured instantly.
Response of Metal Surface
ST-56 (Fluorine resin coating type)
150
ST-56 (Ceramic coating type)
150
0.076
0.127
0.25
100
Up to 500°C
(932°F)
0.1
0.2
0.32
100
1sec
1sec
50
50
0
0
ST-55
Measuring
point
ST-55 has a joint which enables a longer length
Tip Side Thermocouple
(Fluorine resin coating)
Joint
Extended Thermocouple
Terminal
Fluorine resin coating type
Measuring
point
Tip Side Thermocouple
(Ceramic coating)
Joint
Extended Thermocouple
Terminal
Ceramic coating type
ST-56
Measuring
point
ST-56 is a seamless thermocouple
Tip Side Thermocouple
(Fluorine resin coating)
Fluorine resin coating type
Measuring
point
Tip Side Thermocouple
(Ceramic coating)
Ceramic coating type
39
Terminal
Terminal
Temperature Sensors for Extremely Small Surface ST-55
Ceramic coating type : ST-55K-C
Fluorine resin coating type : ST-55K-T
Extended Thermocouple
Lead wire
Joint
Fluorine resin coating
termination
Silicone rubber
coating
Tip
Fluorine resin
coating
Measuring
point
+2%
+20
L1 0 (1000mm or less : L1 0 )
30
3
L2
L3
ST - 55K -
L1
+2%
0 (1000mm
-G-
L2 -
Thermocouple type
or less : L2
+2%
ST - 55K -
- L3
Shape of
Thermocouple
(Element wire
diameter/Coating)
Length of
thermocouple
element wire
Adhesive tape
for tip
Joint specifications
Shape of extended
thermocouple
(Element wire
diameter/Coating)
Length of extended
thermocouple
element wire
Lead wire
termination
0.6
0.3
0.4
L2 -
Shape of Extended Thermocouple
(Element wire diameter/Coating)
Length of extended thermocouple
element wire
Lead wire termination
Joint specifications
Example :ST-55K-CA0300N-G-TD1000-Y
Code
Details
CA ø0.1 Ceramic coating (Single thermocouple type)
CB ø0.2 Ceramic coating (Single thermocouple type)
0.7
0.5
ø0.076
ø0.076
ø0.127
Code : TA
Code : TB
Code : TC
ø0.1 x 2
ø0.2 x 2
Code : CA
Code : CB
Specify every 50mm unit
Code
P
G
N
Details
Polymide tape
Glass cloth base tape
None
N: None
Silicone rubber coating (Max. temperature : 170°C)
Details
Code
TC ø0.127 Fluorine resin coating (Paired thermocouple type)
TD ø0.254 Fluorine resin coating (Paired thermocouple type)
0.7
0.5
ø0.127
Fluorine resin coating
Paired thermocouple type
1.0
0.6
Code : TC
ø0.254
Fluorine resin coating
Paired thermocouple type
Code : TD
Unit : mm (Min.200mm) Specify every 50mm unit • Please select length so that a total resistance of thermocouple become 100Ω or less.
Details
CMP01-K (RKC product) Material : Polyamide (Max. temperature : 140°C (284°F))
CMR01-K (RKC product) Material : PPS resin (Max. temperature : 220°C (428°F))
1260-K (MARINE product) (Max. temperature : 205°C (401°F))
Spade lugs for JIS standard "M3" size screw *1
Conforming to cable connector for DP-350/700 connection
No terminal lugs *terminal soldered
Code
C1
C2
C3
Y
G
N
*1 Spade lugs for JIS standard “M3” size screw is not available if extended thermocouple was specified ø0.127 (Code : TC).
Thermocouple connector
(Code:C3)
L2
45
16.5
8
Code
No symbol
03 to 30
31.7
16
7.9
Conforming to cable connector
for DP-350/700 connection
(Code:G)
L2
50
6.7
Spade lugs for JIS standard "M3"
size screw
(Code : Y)
L2
20 40
No terminal lugs
(Code : N)
L2
20 15 15
Details
Length of exposed tip : 2mm (Standard)
Length of exposed tip : 3 to 30mm (Specify every 1mm unit)
Class :
Accuracy :
Specifications
+20
or less : L2 0 )
Type K
L2
(Only for ST-55K-T )
L1 N - G -
Adhesive tape for tip
Code
Details
TA ø0.076 Fluorine resin coating (Single thermocouple type)
TB ø0.076 Fluorine resin coating (Paired thermocouple type)
TC ø0.127 Fluorine resin coating (Paired thermocouple type)
Thermocouple connector
(Code:C1,C2)
Length of
exposed tip
20 40
+2%
0 (1000mm
Shape of Thermocouple
(Element wire diameter/Coating)
Length of thermocouple element wire
Example :ST-55K-TA0300P-G-TD1000-Y-05
Thermocouple type
3
Thermocouple type
Length of exposed tip
Joint specifications
30
L2
Lead wire termination
Adhesive tape for tip
+20
)
Shape of extended thermocouple
(Element wire diameter/Coating)
Length of extended thermocouple
element wire
Shape of Thermocouple
(Element wire diameter/Coating)
Length of thermocouple element wire
Extended Thermocouple
Fluorine resin coating
Joint
Lead wire
Silicone rubber
termination
coating
Tip
Ceramic
coating
L1 0 (1000mm or less : L1 0 )
20 40
+20
0
Measuring
point
Equal to JIS class 2 (Only for fluorine resin coating type)
±0.5%±1°C
• Accuracy when temperature 100°C on metal surface
(copper) is measured. (Prior to to factory)
Response time : ø0.076 Fluorine resin coating
0.2 sec (Response of 63.2%)
0.8 sec (Response of 95.0%)
ø0.1 x 2 Ceramic coating
0.2 sec (Response of 63.2%)
0.5 sec (Response of 95.0%)
• Accuracy when temperature on metal surface is measured.
Maximum operating temperature
1) Measuring point : Fluorine resin coating : 300°C
(Coating section 260°C)
Ceramic coating : 500°C
2) Adhesive tape : 300°C
3) Joint section : 170°C
4) Extended section : 260°C
Thermocouple resistance per 100mm
ø0.076mm : 20Ω, ø0.127mm : 8Ω, ø0.254mm : 2Ω,
ø0.10mm : 12Ω, ø0.20mm : 3Ω, ø0.32mm : 1.2Ω
Adhesive tape for tip (For fluorine resin coating type)
Mount
Reference
40
25
5
20 10
Polymide adhesive tape
or Glass cloth base adhesive tape
The adhesive tape permits the tip to stick to various types of surfaces.
Repeated peeling and sticking is possible.
<Durability of adhesive tape>
• Up to 150°C (302°F) : Repeated use.
• Up to 200°C (392°F) : Repeated use, as long as temperature stays above 150°C (302°F).
• Up to 250°C (482°F) : Repeated use, as long as temperature stays above 200°C (392°F).
• More than 250°C (482°F) : Adhesive will burn and no longer be used.
However, the number of sticking times differs depending on the
environment where the adhesive is used.
40
Temperature Sensors for Extremely Small Surface ST-56
Ceramic coating type : ST-56K-C
Fluorine resin coating type : ST-56K-T
Measuring
point
Lead wire
termination
Thermocouple
(Fluorine resin coating)
Measuring
point
Lead wire
termination
Thermocouple
(Ceramic coating)
20 40
L2
20 40
L1
ST - 56K -
L1
L
-
ST - 56K -
-L2
Thermocouple type
Adhesive tape for tip
Shape of Thermocouple
(Element wire diameter/Coating)
Lead wire termination
Length of exposed tip
Length of thermocouple element wire
Shape of
Thermocouple
(Element wire
diameter/Coating)
Length of
thermocouple
element wire
Adhesive tape
for tip
Lead wire
termination
Details
ø0.076 Fluorine resin coating (Single thermocouple type)
ø0.076 Fluorine resin coating (Paired thermocouple type)
ø0.127 Fluorine resin coating (Paired thermocouple type)
ø0.254 Fluorine resin coating (Paired thermocouple type)
0.7
0.6
0.3
Length of exposed tip
0.4
Code
Details
CA ø0.1 Ceramic coating (Single thermocouple type)
CB ø0.2 Ceramic coating (Single thermocouple type)
CC ø0.32 Ceramic coating (Single thermocouple type)
1.0
0.6
0.5
ø0.076
ø0.076
ø0.127
ø0.254
ø0.1 x 2
ø0.2 x 2
ø0.32 x 2
Code : TA
Code : TB
Code : TC
Code : TD
Code : CA
Code : CB
Code : CC
Specify every 200mm unit
• Please select length so that a resistance of thermocouple become 100Ω or less.
Code
P
G
N
Details
Polymide tape
Glass cloth base tape
None
Code
C1
C2
C3
Y
G
N
Details
CMP01-K (RKC product) Material : Polyamide (Max. temperature : 140°C (284°F))
CMR01-K (RKC product) Material : PPS resin (Max. temperature : 220°C (428°F))
1260-K (MARINE product) (Max. temperature : 205°C (401°F))
Spade lugs for JIS standard "M3" size screw *1
Conforming to cable connector for DP-350/700 connection
No terminal lugs *terminal soldered
N: None
*1 Spade lugs for JIS standard “M3” size screw is not available if extended thermocouple was specified ø0.076, ø0.127,ø0.10 (Code : TA/TB/TC/CA).
Thermocouple connector
(Code:C1,C2)
Thermocouple connector
(Code:C3)
L2
45
8
Code
No symbol
03 to 30
31.7
16
7.9
Conforming to cable connector
for DP-350/700 connection
(Code:G)
L2
50
6.7
Spade lugs for JIS standard "M3"
size screw
(Code : Y)
L2
20 40
No terminal lugs
(Code : N)
L2
Equal to JIS class 2 (Only for fluorine resin coating type)
±0.5%±1°C
• Accuracy when temperature 100°C on metal surface
(copper) is measured. (Prior to to factory)
Response time : ø0.076 Fluorine resin coating
0.2 sec (Response of 63.2%)
0.8 sec (Response of 95.0%)
ø0.1 x 2 Ceramic coating
0.2 sec (Response of 63.2%)
0.5 sec (Response of 95.0%)
• Accuracy when temperature on metal surface is measured.
Maximum operating temperature
1) Measuring point : Fluorine resin coating : 300°C
(Coating section 260°C)
Ceramic coating : 500°C
2) Adhesive tape : 300°C
3) Joint section : 170°C
4) Extended section : 260°C
Thermocouple resistance per 100mm
ø0.076mm : 20Ω, ø0.127mm : 8Ω, ø0.254mm : 2Ω,
ø0.10mm : 12Ω, ø0.20mm : 3Ω, ø0.32mm : 1.2Ω
Adhesive tape for tip (For fluorine resin coating type)
Mount
Reference
40
25
5
20 10
Polymide adhesive tape
or Glass cloth base adhesive tape
41
20 15 15
Details
Length of exposed tip : 2mm (Standard)
Length of exposed tip : 3 to 30mm (Specify every 1mm unit)
Class :
Accuracy :
Specifications
Shape of Thermocouple
(Element wire diameter/Coating)
Example : ST-56K-CA0500N-Y
16.5
(Only for ST-56K-T )
Adhesive tape for tip
Lead wire termination
Type K
Code
TA
TB
TC
TD
L2
Length of
exposed tip
Thermocouple type
Length of thermocouple element wire
Example : ST-56K-TA0500P-Y-05
Thermocouple type
L N-
The adhesive tape permits the tip to stick to various types of surfaces.
Repeated peeling and sticking is possible.
<Durability of adhesive tape>
• Up to 150°C (302°F) : Repeated use.
• Up to 200°C (392°F) : Repeated use, as long as temperature stays above 150°C (302°F).
• Up to 250°C (482°F) : Repeated use, as long as temperature stays above 200°C (392°F).
• More than 250°C (482°F) : Adhesive will burn and no longer be used.
However, the number of sticking times differs depending on the
environment where the adhesive is used.
Thermocouple Type Non Contact Temperature Sensors : ST-100
Features
When contact thermocouple was used for measuring a surface
temperature of moving objects such as roller and rotationary objects, it
causes tremendous consumption to the sensor or damages to the
surface of the measured object, this caused error in measurement due to
friction heat.
This problem can be solved by putting a distance between a sensor and
a measured object, however, there still causes influence of disturbance
by thermal connection failure, slower response of temperature for
measuring object, poor linearlization or slower response
ST-100 uses uniquely designed triple measuring elements
(thermocouples).
Change of connection method and use of movable structure have solved
these problems.
Moreover, it can be used with connecting indicator and controller for K
type thermocouple since output characteristics is similar to traditional
contact-type thermocouple
Specifications
Application : Roller and Moving objects (Sheets)
Measuring method : Non-contact
Measuring element : Thermocouple K (Daiameter of element : 0.08)
Measuring range : Ambient temperature to 300°C
Response time : Approx.30 sec (Response of 98%)
Approx. 6 sec (Response of 63%)
* At metal surface measuring
Measuring accuracy : Within ±3°C (at 200°C)
* When output is adjusted at the middle of the measuring range.
Measuring distance : Distance between sensor surface of ST-100 and measured object
should be kept 0.5 to 1.5mm
Keep a cetrain distance when measuring.
(1mm when it is with distancer)
Output signal : Thermocouple K output
Lead wire : 6 Silicone rubber protection lead (KX type, 3m)
Output impedance : 50Ω
Example of Application
ST-100
Model Code
Example of non-contact temperature
measurement for rotating heat roller
Model and Suffix Code
Specifications
Thermocouple type
Lead wire length
(unit: mm)
Lead wire
termination
Lead protection
Distancer (Roller)
ST-100
K
Type K
1000 to 20000mm (Standard :3000mm)
K
/
*
*1000 to 5000mm (Specify 500mm each)
6000 to 20000mm (Specify 1000mm each)
Spade lugs for JIS standard "M3" size screw
Spade lugs for JIS standard "M4" size screw
No terminal lugs
No terminal lugs *terminal soldered
Silicone rubber (Blue)
None
With distancer (Roller)
Y3
Y4
C
N
D
No symbol
D
External Dimension
Unit : mm
With distancer (Roller)
Output adjustment
screw
6
48
33
6
Output adjustment
screw
20
6
11
29
70
6
2-8
25
30
24
28
Measuring point
1 25 to 32
57
56
0.5 to 1.5 28 to 32
56
30
11
Lead wuire
11
48
Lead wuire
Measuring point
2-8
8
25
20
27
48
31
65
28
23
68
Fluorocarbon
polymers
roller
42
Thermocouple Type Non-Contact Temperature Sensors : ST-100K
Features
ST-100K, a compacted type of ST-100, is a non-contact thermocouple
sensor for surface measurement of moving objects such as roller,
rotating objects, and sheet.
Specifications
Application : Insulator surface (Roller and Moving objects (Sheets))
Measuring method : Non-contact
Measuring element : Thermocouple K, Class 2 (Daiameter of element : 0.076)
Measuring range : Ambient temperature to 260°C
(Maximum continuous operating temperature : 200°C)
Measuring accuracy : Within ±2°C (Ambient temperature to 150°C)
Within ±5°C (150 to 260°C)
* Measuring distance : 0.5mm
If a measuring distance will become within 0.5mm, indicated
value is higher than actual temperature.
Measuring distance : 0.5mm (Fixed)
Spring stroke : 0.5 to 2mm (ST-100K)
0.2 to 1mm (ST-100K1)
Output signal : Thermocouple K output
Lead wire : Fiberglass
* Response time (reference values) : Approx.3.5 sec (90%) Typ.
Model Code
Model and Suffix Code
Specifications
Lead wire length
(unit: mm)
ST-100KST-100K1500 to 5000mm
* 500 to 990mm (Specify 100mm each)
1000 to 5000mm (Specify 500mm each)
Fiberglass
Spade lugs for JIS standard "M3" size screw
Ring lugs for JIS standard "M4" size screw
Thermocouple connector (CSP01-K + CLP-A)
Thermocouple connector (CMP01-K + CLP-B)
No terminal lugs *terminal soldered
Lead protection
Lead wire
termination
EXB
Y3
R4
TE1
TE3
N
External Dimension
Unit : mm
ST-100K
ST-100K1
50
40
30
40
2-4.3
Screw size : M4
10
12
2-3.3
Screw size : M3
2
20
Spring
16
Lead wuire
30
15
22
43
14
26.5
6.5
12
4
12
25.5
12
0.5
C1
0.5
6.5
14
18
11
3.5
59
Lead wuire
39.5
10
3
15
2
6
9
Spring
4
12
25.5
Rotating Roll Surface Temperature Measuring Sensors JBS-3898
Features
JBS-3898 is a sensor for surface temperature
measurement, and it is small and easily connectable.
Pressed by the spring, a sensor touches to a
measuring part and realizes a stable temperature
measurement. Non contact type is capable of easy
and accurate measurement for rotary roll and belt
with shiny surface which is difficult to be measured.
Specifications
Thermocouple Type
: Type K, Class 2 (JIS)
Type T, Class 1 (JIS)
Measuring accuracy : Type K
±2.5°C [0 to 50°C]
±(1.0°C + 0.03|t|) or ±0.045|t|, whichever is larger.
[50 to 300°C] t: measuring temperature
Type T
±2°C [0 to 50°C]
±(1.0°C + 0.03|t|) [50 to 100°C] t: measuring temperature
Response time
: Type K, Fiberglass lead wire
1.0 sec (Response of 63.2%). 3.6 sec (Response of 95.0%)
Type K, Fluorocarbon polymers lead wire
1.2 sec (Response of 63.2%). 6.3 sec (Respose of 95.0%)
Type T, Fluorocarbon polymers lead wire
2.0 sec (Response of 63.2%). 6.0 sec (Response of 95.0%)
Operating temperature : Type K,0 to 300°C (Fiberglass lead wire)
Type K,0 to 200°C (Fluorocarbon polymers lead wire)
Type T,0 to 100°C (Fluorocarbon polymers lead wire)
Contact plate
: SUS304, Width 7mm,Thickness:0.15mm
Lead wire
: Fiberglass lead wire, Element diameter (0.32)
Fluorocarbon polymers lead wire, Element diameter (0.2)
Weight
: 23g (Fiberglass lead wire, Lead length : 3m,
Lead wire termination : Spade lugs for JIS standard "M3" size screw)
2 types are available (Right-rotary and left-rotary types)
For directions of rotation and mounting of roller, we have
right-rotary and left-rotary types.
Top view
For right-rotary
For left-rotary
Roller
Measuring
parts
Measuring JBS-3898
parts
(This is figure
from upper side.)
Roller
JBS-3898
(This is figure
from upper side.)
Model Code
Model and Suffix Code
Specifications
Lead wire length
(unit: mm)
JBS-3898
100 to 8000mm
* 100 to 990mm (Specify 10mm each)
1000 to 8000mm (Specify 500mm each)
EXB
EXF
Lead protection
Fiberglass lead wire (Type K only)
Fluorocarbon polymers lead wire
Lead wire
termination
Spade lugs for JIS standard "M3" size screw
Spade lugs for JIS standard "M4" size screw
No terminal lugs *terminal soldered
Thermocouple type
Y3
R4
N
Type K
K
T
Type T
Directions of rotaion
R
L
For right-rotary
For left-rotary
External Dimension
Unit : mm
For right-rotary
Lead wire
termination
Spade lugs
Silicon Varnish
Glass Tube
7
Soldered
after welding
22
Lead wire
(Element wire)
2
Rivet
Silver
brazing
15 ±0.2
20
Measuring
side
45
8
SUS304 t=0.15
L
5
10
13
43.5
2-M4
41
44
General type • Sheathed
Resistance Temperature Detectors
Resistance Temperature Detector
Platinum Resistance Temperature Detector (Pt100)
Temperature Characteristic
3.5
Resistivity (Rt/RO)
The value of metal resistance changes according to temperature
change. This measuring element which utilizes a relationship
between temperature and resistance is called Resistance
Temperature Detectors (RTDs). Platinum, nickel, and copper are
used as metals of RTDs, and utilizes a characteristic that the
resistance increases as the temperature rises.
Platinum is the most excellent element in accuracy and stability and
is defined in "JIS" standard.
Platinum is fragile compared with the other elements, be cautious
about its usage at a place where vibrations and shocks will occur.
All of our RTDs are platinum ones of the type Pt100.
3.0
2.5
2.0
1.5
1.0
0.5
Sheathed Resistance Temperature Detector
Inside the thin stainless steel pipe, element is located, and then
Stainless pipe is filled with a MgO.
This type of sensor features in excellent responsiveness and
vibration resistances.
0
-200 -100
0
100 200 300 400 500 600 650
Temperature (ºC)
Terminal head type
Sleeve type
R-101(General type)/R-101S(Sheathed type)
R-30,35(General type)/R-30S,35S(Sheathed type)
R-111(General type)/R-111S(Sheathed type)
No-sleeve type
Metal connector type
(Only for General type)
R-90(General type)/R-90S(Sheathed type)
R-102
■ Sanitary type Resistance Temperature Detector
Sanitary Sensors are able to keep cleanness of foreign matters and bacteria, users can relief to apply them in food, beverage,
and chemical processing applications.
Protection tube is #400 polish finishing.
Ferrule cap and hexagon nut and linear cap are available.
Protection tube material is SUS316.
Electropolishing is available (Specify from "option" code).
Ferrule cap
Hexagon nut and Linear cap
(Sheathed Resistance Temperature Detector)
R-31S, R-36S
45
(Sheathed Resistance Temperature Detector)
R-31RS, R-36RS
Resistance Temperature Detectors : R-101/R-111
Red
(A)
Black
(B)
Black
(B)
d1
Serial number
Heat shrink
label
tube
L
Specification
label
L1
40
L2
Hexagon
Crimp
Sleeve
Filled with
Epoxy Resin
(MAX 120ºC)
Lead wire
termination
Lead wire
(3-wire system)
Red
Serial number
label
Specification
label
Heat shrink
tube
(A)
Black
(B)
Black
(B)
L
40
120°
Protection tube
(SUS316)
Argon welding
d
R - 101 - d - L1 - L -
R - 111 - d - L1 - L2 - L -
- - - -
- - - -
Diameter of protection tube
Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Resistance temperature detector type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Length of protection tube
Example :R-111-5-100-30-2000-EXA-Y-PDM-NG-N
Example :R-101-5-100-2000-EXA-Y-PDM-NG-N
Diameter of
protection tube
Resistance temperature detector type
3.0, 3.2, 4.0, 4.8, 5.0, 6.0, 8.0
-1: Specify length by “mm”
(100mm or more, L1+L2=1,000mm or less)
-2: Specify length by “mm”
(25mm or more, L1+L2=1,000mm or less)
• Length is 25mm without specification.
Specify length by “mm” (100mm to 1,000mm)
Length of
protection tube
• Please contact distributors regarding other length.
Lead wire length
Specify length by “mm” (100mm or more)
• Please contact distributors regarding other length.
Lead protection
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Lead wire
termination
Code
Details
Code
Details
No terminal lugs * terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1603-P)
•See Page7
Resistance
temperature
detector type
Measuring junction
Mounting bracket
Operating temperature
Details
Code
0 to 220ºC
PDP Pt100 Middle Temperature Type (3.0 to 4.0)
0 to 350ºC
PDM Pt100 Middle Temperature Type (4.8 or more)
0 to 500ºC
PDH Pt100 High Temperature Type (4.8 or more)
Code
EXD
EXE
EXF
Operating temperature
-20 to +90ºC
-55 to +180ºC
0 to 200ºC
Details
PVC (polyvinyl chloride)
Silicone rubber
Fluorocarbon polymers (FEP)
Operating temperature
Details
Code
PAP JPt100 Middle Temperature Type (3.0 to 4.0)
0 to 220ºC
PAM JPt100 Middle Temperature Type (4.8 or more)
0 to 350ºC
PAH JPt100 High Temperature Type (4.8 or more)
0 to 500ºC
Code
NG
O
Details
Ungrounded
* Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Exposed
Please contact with our distributors.
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
• Please contact distributors regarding other mounting bracket.
Class : class B * Class A is available (Please specify when you order) Sleeve Dimension (d1)
Element : Single element * Double element is available.
Diameter of
protection tube
(Diameter of protection tube : 4.8 or more)
3.0 to 5.0 6.0 to 8.0
Lead
(Please specify when you order)
wire type
Specifications
Maximum temperature for use
Diameter of protection tube
3.0 to 4.0 (Middle temperature type : Code PDP/PAP)
4.8 or more (Middle temperature type : Code PDM/PAM)
4.8 or more (High temperature type : Code PDH/PAH)
• Stainless flexible lead wire is available
Model Code : R-101F/R-111F
MAX 120ºC
Reference
SUS304
Compensation lead wire
(Fiberglass)
For flexible lead wire, the dimension of the sleeve is
10 x 40mm.
• No waterproof
EXA,EXB,EXC
EXD,EXE,EXF
Operating temperature
0 to 220ºC
0 to 350ºC
0 to 500ºC
8×40
5
40
• Spring loaded type is available
(Please specify when you order)
• Material of protection tube
Sleeve is
Lead wire
filled with epoxy
(Compensation
(MAX 120ºC) Spring
(SUS304) lead wire)
Sleeve
70
10×40
d1
d
120°
-2
d1
Filled with
Lead wire
Epoxy Resin (3-wire system)
(MAX 120ºC)
Lead wire
termination
-1
L1
Hexagon
Argon welding Protection Crimp
tube
(SUS304)
Sleeve
SUS316 is available.
(Please specify when you order)
L
Dimensions for the spring loaded sleeve is as follows.
• Protection tube 1.0 to 4.8 with extension lead wire
EXC, EXD : 10 x 40mm
• Protection tube 6.0 to 8.0 : 10 x 40mm
• Except from the above: : 8 x 40mm
46
Resistance Temperature Detectors : R-102
Diameter of protection tube (d) : 4.0 or more
Diameter of protection tube (d) : 3.0, 3.2
d
120°
Argon welding
d
Lead wire
Filled with Epoxy Resin (3-wire system)
Protection
tube
(SUS304)
Argon welding
Lead wire
termination
Red
(A)
Black
(B)
Black
(B)
Serial number
Heat shrink
label
tube
120°
R - 102 - d - L1 - L -
Hexagon
Crimp
(A)
Black
(B)
Black
(B)
L
R - 102 - d - L1 - L -
- - - -
Lead wire
termination
Lead wire
(3-wire system)
Red
Serial number
Heat shrink
label
tube
L1
L
L1
Protection
tube
(SUS304)
- - - -
Diameter of protection tube
Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Resistance temperature detector type
Length of protection tube
Resistance temperature detector type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Example :R-102-3.2-100-2000-EXF-Y-PDM-NG-N
Diameter of
protection tube
Length of
protection tube
Lead wire length
Example :R-102-5-100-2000-EXA-Y-PDM-NG-N
3.0, 3.2
4.0, 4.8, 5.0, 6.0, 8.0
Specify length by “mm” (50mm to 500mm)
• Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
Code
EXF
Code
Operating temperature
Details
Fluorocarbon polymers (FEP)
0 to 200ºC
EXA
EXB
Lead protection
EXC
EXD
EXE
EXF
Lead wire
termination
Resistance
temperature
detector type
Measuring junction
Mounting bracket
Operating temperature
Details
Fiberglass with stainless steel
(Diameter of protection tube : 4.8 or more)
Fiberglass
(Diameter of protection tube : 4.8 or more)
PVC (polyvinyl chloride) with copper wire braided
(Diameter of protection tube : 5.0 or more)
PVC (polyvinyl chloride)
(Diameter of protection tube : 5.0 or more)
Silicone rubber
(Diameter of protection tube : 5.0 or more)
Fluorocarbon polymers (FEP)
(Diameter of protection tube : 4.0 or more)
0 to 150ºC
0 to 150ºC
-20 to +90ºC
-20 to +90ºC
-55 to +180ºC
0 to 200ºC
Code
Details
Code
Details
No terminal lugs * terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1603-P)
•See Page7
Code
Details
Operating temperature
0 to 220ºC
PDP Pt100 Middle Temperature Type
0 to 220ºC
PAP JPt100 Middle Temoerature Type
Code
PDP
PDM
PAP
PAM
Details
Operating temperature
Pt100 Middle Temperature Type (4.0)
0 to 220ºC
Pt100 Middle Temperature Type (4.8 or more)
0 to 300ºC
JPt100 Middle Temoerature Type (4.0)
0 to 220ºC
JPt100 Middle Temperature Type (4.8 or more)
0 to 300ºC
Code
NG
O
Details
Ungrounded
* Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Exposed
Please contact with our distributors.
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
• Please contact distributors regarding other mounting bracket.
Class : class B * Class A is available
(Please specify when you order)
Element : Single element
Maximum temperature for use : 0 to 220ºC
Specifications
• Material of protection tube
• Spring loaded type is available
(Please specify when you order)
Spring
(SUS304)
Reference
47
70
Lead wire
L
Class : class B * Class A is available (Please specify when you order)
Element : Single element * Double element is available.
(Diameter of protection tube : 8.0 or more)
(Please specify when you order)
Maximum temperature for use
Operating temperature
Diameter of protection tube
4.0
(Middle temperature type : Code PDP/PAP)
0 to 220ºC
4.8 or more (Middle temperature type : Code PDM/PAM)
0 to 300ºC
SUS316 of protection tube is
available.
(Please specify when you order)
Resistance Temperature Detectors : R-30/R-35
d
Terminal head
Protection
tube
(SUS304)
Argon welding
Specification
label
120° (10 or more
:Hemisphere)
d
120° (10 or more
:Hemisphere)
Terminal head
Specification
label
d
Protection
tube
(SUS304)
Argon welding
Serial number
label
L1
Serial number
label
60
PF3/8
PF1/2
L1
No lead wire
R - 30 - d - L1 - - With lead wire
R - 30 - d - L1 - L -
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Lead wire termination
Resistance temperature detector type
Sensing junction
Mounting bracket
With lead wire
R - 35 - d - L1 - L Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Example :R-30-5-100-PDM-NG-N (No lead wire)
:R-30-5-100-2000-EXA-Y-PDM-NG-N (With lead wire)
- - - Lead wire termination
Resistance temperature detector type
Sensing junction
Mounting bracket
Example :R-35-5-100-PDM-NG-N (No lead wire)
:R-35-5-100-2000-EXA-Y-PDM-NG-N (With lead wire)
3.0, 3.2, 4.8, 5.0, 6.0
6.4, 8.0, 10.0, 12.0
4.8, 5.0, 6.0, 6.4, 8.0, 10.0, 12.0, 15.0
Length of
protection tube
Specify length by “mm” (100mm to 1,000mm)
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Lead wire length
Specify length by “mm” (100mm or more)
Lead wire
termination
No need to specify in case of
without lead wire
Diameter of
protection tube
Lead
protection
Resistance
temperature
detector type
Measuring junction
Mounting bracket
82
No lead wire
R - 35 - d - L1 - - -
• Please contact distributors regarding 21.7.
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Operating temperature
-20 to +90ºC
-55 to +180ºC
Code
Details
Code
Details
No terminal lugs * terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1603-P)
•See Page7
Operating temperature
Details
Code
0 to 220ºC
PDP Pt100 Middle Temperature Type (3.0 to 4.0)
0 to 300ºC
PDM Pt100 Middle Temperature Type (4.8 or more)
0 to 500ºC
PDH Pt100 High Temperature Type (4.8 or more)
Code
NG
O
Code
A
B
C
Operating temperature
Details
Code
PAP JPt100 Middle Temperature Type (3.0 to 4.0)
0 to 220ºC
PAM JPt100 Middle Temperature Type (4.8 or more)
0 to 300ºC
PAH JPt100 High Temperature Type (4.8 or more)
0 to 500ºC
Details
Ungrounded
* Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Exposed
Please contact with our distributors.
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
• Please contact distributors regarding other mounting bracket.
Specifications
Class : class B * Class A is available (Please specify when you order)
Element : Single element * Double element is available. (Only R-35)
(Please specify when you order)
Maximum temperature for use
Operating temperature
Diameter of protection tube
0 to 220ºC
3.0 to 4.0 (Middle temperature type : Code PDP/PAP)
0 to 300ºC
4.8 or more (Middle temperature type : Code PDM/PAM)
0 to 500ºC
4.8 or more (High temperature type : Code PDH/PAH)
• Material of protection tube
SUS316 is available.
(Please specify when you order)
Reference
48
d
Resistance Temperature Detectors : R-90
Serial
number
label
Argon welding Protection tube
(SUS304)
120°
L1
Adapter (SCK-1603-A)
Plug (SCK-1603-P)
43
42
No lead wire
R - 90 - d - L1 - - With lead wire
R - 90 - d - L1 - L -
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Lead wire termination
Resistance temperature detector type
Sensing junction
Mounting bracket
Example :R-90-5-100-PDM-NG-N (No lead wire)
:R-90-5-100-2000-EXA-Y-PDM-NG-N (With lead wire)
Lead
protection
Lead wire
termination
No need to specify in case of
without lead wire
Diameter of
protection tube
Length of
protection tube
Lead wire length
Resistance
temperature
detector type
Measuring junction
Mounting bracket
3.0, 3.2, 4.8, 5.0, 6.0, 8.0
Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Details
PVC (polyvinyl chloride)
Silicone rubber
Code
Details
Code
Details
No terminal lugs * terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1603-P)
•See Page7
Operating temperature Code
Operating temperature
Details
Details
Code
PAP JPt100 Middle Temperature Type (3.0 to 4.0)
0 to 220ºC
0 to 220ºC
PDP Pt100 Middle Temperature Type (3.0 to 4.0)
PAM JPt100 Middle Temperature Type (4.8 or more)
0 to 350ºC
0 to 350ºC
PDM Pt100 Middle Temperature Type (4.8 or more)
Code
NG
O
Code
A
B
C
Details
Ungrounded
* Exposed-junction type is available depending on specification such as shapes, environment of usage, etc.
Exposed
Please contact with our distributors.
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Class : class B * Class A is available (Please specify when you order)
Element : Single element * Double element is available.
(Diameter of protection tube : 4.8 or more)
(Please specify when you order)
Specifications
Maximum temperature for use
Diameter of protection tube
3.0 to 4.0 (Middle temperature type : Code PDP/PAP)
4.8 or more (Middle temperature type : Code PDM/PAM)
• Material of protection tube
SUS316 is available.
(Please specify when you order)
Operating temperature
0 to 220ºC
0 to 350ºC
Connector
Pin No.
Single Element
Double Element
3
1
3
Reference
2
Pin No. Details
A
1
2
B
3
b
SCK-1603-
2
4
1 6 5
Pin No. Details Pin No. Details
A
A
1
1
2
B
2
B
3
b
3
b
SCK-1606-
For connector for R-90, Connector manufactured by Sanwa
Connector Laboratory Co., Ltd. is used as standard.
Nanaboshi Electric Mfg brand is also available
(Please specify when you order).
Please specify in case of no need of the plug.
49
Operating temperature
-20 to +90ºC
-55 to +180ºC
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
Sheathed Resistance Temperature Detectors : R-101S/R-111S
40
L2
Lead wire
termination
d1
Red
(A)
Black
(B)
Black
(B)
Serial number
Heat shrink
label
tube
L
Specification
label
L1
Lead wire
(3-wire system)
Filled with
Epoxy Resin
(MAX 120ºC)
Specification
label
Lead wire
termination
Lead wire
(3-wire system)
Red
Serial number
label
(A)
Black
(B)
Black
(B)
Heat shrink
tube
L
40
120°
d1
Filled with
Epoxy Resin
Sleeve (MAX 120ºC)
Protection
tube
(SUS316)
Argon welding
d
R - 101S - d - L1 - L -
R - 111S - d - L1 - L2 - L -
- - - -
Diameter of protection tube
- - - Lead wire termination
Diameter of protection tube
Lead wire termination
Length of protection tube
Resistance temperature detector type
Lead wire length
Sensing junction
Lead wire length
Sensing junction
Lead protection
Mounting bracket
Lead protection
Mounting bracket
Length of protection tube
Example :R-101S-4.8-100-2000-EXA-Y-PDM-NG-N
Diameter of
protection tube
Length of
protection tube
Resistance temperature detector type
Example :R-111S-4.8-100-30-2000-EXA-Y-PDM-NG-N
3.2, 4.8, 6.4, 8.0
-1: Specify length by “mm”
(100mm or more, L1+L2=1,000mm or less)
-2: Specify length by “mm”
(25mm or more, L1+L2=1,000mm or less)
• Length is 25mm without specification.
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Lead wire length
Specify length by “mm” (100mm or more)
Lead protection
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Lead wire
termination
Resistance
temperature
detector type
Measuring junction
Mounting bracket
Code
EXD
EXE
EXF
Details
PVC (polyvinyl chloride)
Silicone rubber
Fluorocarbon polymers (FEP)
Operating temperature
-20 to +90ºC
-55 to +180ºC
0 to 200ºC
Code
Details
Code
Details
No terminal lugs * terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1603-P)
•See Page7
Operating temperature Code
Operating temperature
Details
Details
Code
-200 to +100ºC PAL JPt100 Low Temperature Type
-200 to 100ºC
PDL Pt100 Low Temperature Type
0 to 350ºC
PAM JPt100 Middle Temperature Type
0 to 350ºC
PDM Pt100 Middle Temperature Type
0 to 500ºC
PAH JPt100 High Temperature Type
0 to 500ºC
PDH Pt100 High Temperature Type
Code
NG
Code
A
B
C
Details
Ungrounded
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
• Please contact distributors regarding other mounting bracket.
Specifications
Maximum temperature for use
Diameter of protection tube
3.0 to 4.0 (Low temperature type : Code PDL/PAL)
4.8 or more (Middle temperature type : Code PDM/PAM)
4.8 or more (High temperature type : Code PDH/PAH)
Sleeve Dimension (d1)
Operating temperature
-200 to +100ºC
0 to 350ºC
0 to 500ºC
It is available to cover Fuluorine resin tube with φ4.8
protection tube (SUS316). Total Diameter becomes φ6.0. Model Code : R-101S/R-111S
It is also available to do coating with R-101S whose
MAX 120ºC
tube is more than φ3.2.
These model codes are R-101SC in this case.
3
8
Fuluorine
Silicone
SUS316 resin tube
Sleeve
(FEP)
rubber
Mgo
Isolation
Crimp (SUS304) tube
Lead wire
45
MAX 200ºC
L
3.2, 4.8
6.4, 8.0
8×40
10×40
EXA,EXB,EXC
EXD,EXE,EXF
• Stainless flexible lead wire is available
• Fluor resin coating is available
Reference
Diameter of
protection tube
Lead
wire type
5
40
d1
Class : class B * Class A is available (Please specify when you order)
Element : Single element * Double element is available.
(Diameter of protection tube : 4.8 or more)
(Please specify when you order)
6
4.8
d
120°
Protection
tube
(SUS316)
L1
Argon welding
Hexagon
Crimp
Hexagon
Crimp
Sleeve
• Spring loaded type is available
(Please specify when you order)
Filled with
Lead wire
Epoxy Resin Spring
(Compensation
(MAX 120ºC)
(SUS304) lead wire)
Sleeve
70
SUS304
Compensation
lead wire
(Fiberglass)
For flexible lead wire, the dimension of
the sleeve is 10 x 45mm.
• No waterproof
L
Dimensions for the spring loaded sleeve
is as follows.
• Protection tube 3.2 with extension lead wire
EXE : 8 x 40mm
• Protection tube 4.8 to 8.0 with extension
lead wire : 8 x 45mm
• Except from the above: : 10 x 45mm
50
Argon welding
120°
Argon welding
Terminal head
Specification
label
Protection
tube
(SUS316)
d
d
Sheathed Resistance Temperature Detectors : R-30S/R-35S
Protection
tube
(SUS316)
120°
Terminal head
Specification
label
Serial number
label
L1
Serial number
label
60
PF3/8
PF1/2
L1
No lead wire
R - 30S - d - L1 - - -
82
No lead wire
R - 35S - d - L1 - - -
With lead wire
R - 30S - d - L1 - L -
With lead wire
R - 35S - d - L1 - L -
- - - Lead wire termination
Resistance temperature detector type
Sensing junction
Mounting bracket
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
- - - Lead wire termination
Resistance temperature detector type
Sensing junction
Mounting bracket
Example :R-30S-4.8-100-PDM-NG-N (No lead wire)
Example :R-35S-5-100-PDM-NG-N (No lead wire)
:R-30S-4.8-100-2000-EXA-Y-PDM-NG-N (With lead wire)
:R-35S-5-100-2000-EXA-Y-PDM-NG-N (With lead wire)
Diameter of
protection tube
3.2, 4.8, 6.4, 8.0
4.8, 6.4, 8.0
Length of
protection tube
Specify length by “mm” (100mm to 1,000mm)
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding other length.
• Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
Lead
protection
Lead wire
termination
No need to specify in case of
without lead wire
Lead wire length
Resistance
temperature
detector type
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Operating temperature Code
Operating temperature
Details
Details
Code
-200 to +100ºC PAL JPt100 Low Temperature Type
-200 to 100ºC
PDL Pt100 Low Temperature Type
0 to 350ºC
PAM JPt100 Middle Temperature Type
0 to 350ºC
PDM Pt100 Middle Temperature Type
0 to 500ºC
PAH JPt100 High Temperature Type
0 to 500ºC
PDH Pt100 High Temperature Type
Code
NG
Details
Ungrounded
Mounting bracket
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Class : class B * Class A is available (Please specify when you order)
Element : Single element * Double element is available. (Only for R-35S)
(Please specify when you order)
Maximum temperature for use
Diameter of protection tube
Low temperature type : Code PDL/PAL
Middle temperature type : Code PDM/PAM
High temperature type : Code PDH/PAH
• Fluor resin coating is available
6
4.8
It is available to cover Fuluorine resin tube with φ4.8
protection tube (SUS316). Total Diameter becomes φ6.0.
It is also available to do coating with R-101S whose
tube is more than φ3.2.
These model codes are R-30SC/R-35SC in this case.
Reference
SUS316
Mgo
Isolation
3
Fuluorine
resin tube
(FEP)
L1
Operating temperature for regular use : 180ºC
Maximum temperature : 200ºC
Example :
R-30SC-6.0-100-PDM-NG-N (No lead wire)
• Please contact distributors regarding Fuluorine coating type.
51
Operating temperature
-20 to +90ºC
-55 to +180ºC
Code
Details
Code
Details
No terminal lugs * terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1603-P)
•See Page7
Measuring junction
Specifications
Details
PVC (polyvinyl chloride)
Silicone rubber
Operating temperature
-200 to +100ºC
0 to 350ºC
0 to 500ºC
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
Sheathed Resistance Temperature Detectors : R-90S
Serial
number
label
d
Argon welding Protection tube
(SUS316)
120°
L1
Adapter (SCK-1603-A)
Plug (SCK-1603-P)
43
42
No lead wire
R - 90S - d - L1 - - With lead wire
R - 90S - d - L1 - L -
- - - -
Diameter of protection tube
Length of protection tube
Lead wire length
Lead protection
Lead wire termination
Resistance temperature detector type
Sensing junction
Mounting bracket
Example :R-90S-4.8-100-PDM-NG-N (No lead wire)
:R-90S-4.8-100-2000-EXA-Y-PDM-NG-N (With lead wire)
Diameter of
protection tube
Length of
protection tube
No need to specify in case of
without lead wire
Lead wire
termination
Specify length by “mm” (100mm to 1,000mm)
• Please contact distributors regarding other length.
Specify length by “mm” (100mm or more)
Lead wire length
Lead
protection
3.2, 4.8, 6.4, 8.0
Resistance
temperature
detector type
Measuring junction
Mounting bracket
Operating temperature
Details
Code
EXA Fiberglass with stainless steel
0 to 150ºC
EXB Fiberglass
0 to 150ºC
EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC
Code
EXD
EXE
Operating temperature
-20 to +90ºC
-55 to +180ºC
Code
Details
Code
Details
No terminal lugs * terminal soldered
Y Spade lugs for JIS standard "M3" size screw N
R Ring lugs for JIS standard "M4" size screw
M Metal connector (SCK-1603-P)
•See Page7
Operating temperature Code
Operating temperature
Details
Details
Code
-200 to +100ºC PAL JPt100 Low Temperature Type
-200 to 100ºC
PDL Pt100 Low Temperature Type
0 to 350ºC
PAM JPt100 Middle Temperature Type
0 to 350ºC
PDM Pt100 Middle Temperature Type
0 to 500ºC
PAH JPt100 High Temperature Type
0 to 500ºC
PDH Pt100 High Temperature Type
Code
NG
Details
Ungrounded
Code
A
B
C
Details
Fixed nipple (nut)
Rotary nipple (nut)
Fixed flange
Code
E
N
Details
Compression fitting
No bracket
• Please contact distributors regarding other mounting bracket.
Specifications
Details
PVC (polyvinyl chloride)
Silicone rubber
Specify size of mounting bracket when code is
"A", "B", or "E". (See Page 6)
Specify size of flange when code is "C".
(See Page 6)
Class : class B * Class A is available (Please specify when you order)
Element : Single element * Double element is available.
(Diameter of protection tube : 4.8 or more)
(Please specify when you order)
Maximum temperature for use
Operating temperature
Diameter of protection tube
-200 to +100ºC
Low temperature type : Code PDL/PAL
0 to 350ºC
Middle temperature type : Code PDM/PAM
0 to 500ºC
High temperature type : Code PDH/PAH
Connector
Pin No.
Single Element
Double Element
3
1
3
Reference
2
Pin No. Details
A
1
B
2
b
3
SCK-1603-
2
4
1 6 5
Pin No. Details Pin No. Details
A
A
1
1
2
B
2
B
3
b
3
b
SCK-1606-
For connector for R-90S, Connector manufactured by Sanwa
Connector Laboratory Co., Ltd. is used as standard.
Nanaboshi Electric Mfg brand is also available
(Please specify when you order).
Please specify in case of no need of the plug.
52
Sanitary type Sheathed Resistance Temperature Detectors : R-31S/R-36S
8
Argon welding
120°
Protection tube(SUS316)
#400 polish finishing
(Electrolytic polishing : Optional)
Protection tube(SUS316)
#400 polish finishing
(Electrolytic polishing : Optional)
Argon
welding
R - 31S - d - L1 - L2 -
L2
(50)
70
L1
R - 36S - d - L1 - L2 -
- - Resistance temperature detector type
Ferrule cap type
Ferrule cap material
Optional (Electrolytic polishing)
Diameter of protection tube
Length of protection tube (L1)
Length of Terminal head - ferule cap (L2)
Argon
welding
PF3/8
L2
(50)
L1
90
72
120°
d
8
Ferrule cap
Argon welding
8
7
Argon welding
5
5
d
Argon welding
Terminal
head
Terminal
head
Ferrule cap
Diameter of protection tube
Length of protection tube (L1)
Length of Terminal head - ferule cap (L2)
Example : R-31S-4.8-500-50-DMA-10S-1-E
Details
Code
DMA Pt100 (Class A)
DMB Pt100 (Class B)
Resistance temperature detector type
Ferrule cap type
Ferrule cap material
Optional (Electrolytic polishing)
Example : R-36S-4.8-500-50-DMA-10A-2-E
Details
Code
AMA JPt100 (Class A)
AMB JPt100 (Class B)
Details
8A *1
10A *1
15A *1
Ferrule cap type
Code
8A
10A
15A
Ferrule cap
material
Code
1
2
Details
SUS304
SUS316L *1
Optional
(Electrolytic
polishing)
Code
E
N
Details
Electrolytic polishing
No electrolytic polishing
Specifications
Code
10S
15S
20S
25S
Details
1.0S
1.5S
2.0S
2.5S
Class : class A or B
Element : Single element * Double element is available. (Only R-36S) (Please specify when you order)
Specified current : 2mA
Operating temperature: -40 to +200ºC
B
A
11
53
Details
3.0S
*1 : 8A,10A,15A : Only SUS316 (Code :2)
Ferrule cap dimensions
Reference
Code
30S
A
Size
8A,10A,15A 34
50.5
1S, 1.5S
64
2S
2.5S
77.5
3S
91
B
21.7
38.1
50.8
63.5
76.3
PF1/2
- - -
Diameter of
3.2, 4.8, 6.4, 8.0
protection tube
Length of
Specify length by “mm” (100mm to 500mm)
protection tube (L1)
Length of Terminal
50mm (Standard)
head - ferule cap
(L2)
Resistance
temperature
detector type
90
Sanitary type Sheathed Resistance Temperature Detectors : R-31RS/R-36RS
Terminal
head
Argon welding
d
L2
(50)
L1
120°
Argon
Protection tube(SUS316)
welding
#400 polish finishing
(Electrolytic polishing : Optional)
PF3/8
70
L2
(50)
L1
R - 31RS - d - L1 - L2 -
R - 36RS - d - L1 - L2 -
- - Resistance temperature detector type
Hexagon nut type
Liner cap material
Optional (Electrolytic polishing)
Diameter of protection tube
Length of protection tube (L1)
Length of Terminal head - Linear cap (L2)
90
72
Argon
Protection tube(SUS316)
welding
#400 polish finishing
(Electrolytic polishing : Optional)
8
8
120°
Terminal
head
78
Argon welding
5
5
d
Hexagon nut (SUS304),
Liner cap
Hexagon nut (SUS304),
Liner cap
Diameter of protection tube
Length of protection tube (L1)
Length of Terminal head - Linear cap (L2)
90
PF1/2
- - Resistance temperature detector type
Hexagon nut type
Liner cap material
Optional (Electrolytic polishing)
Example : R-36RS-4.8-500-50-DMA-15S-1-E
Example : R-31RS-4.8-500-50-DMA-15S-1-E
Diameter of
3.2, 4.8, 6.4, 8.0
protection tube
Length of
protection tube (L1) Specify length by “mm” (100mm to 500mm)
Length of Terminal
head - Liner cap
50mm (Standard)
(L2)
Resistance
temperature
detector type
Details
Code
DMA Pt100 (Class A)
DMB Pt100 (Class B)
Details
Code
AMA JPt100 (Class A)
AMB JPt100 (Class B)
Details
Details
Code
25S 2.5S
30S 3.0S
Hexagon nut type
Code
10S
15S
20S
1.0S
1.5S
2.0S
Liner cap
material
Code
1
2
Details
SUS304
SUS316L
Optional
(Electrolytic
polishing)
Code
E
N
Details
Electrolytic polishing
No electrolytic polishing
Specifications
Class : class A or B
Element : Single element * Double element is available. (Only R-36RS) (Please specify when you order)
Specified current : 2mA
Operating temperature: -40 to +200ºC
Liner cap
Hexagon nut (SUS304)
A
L
Size
1S
1.5S
2S
2.5S
3S
A
33.8
47
60.5
74
87.5
L
11.5
11.5
11.5
11.5
11.5
Size
1S
1.5S
2S
2.5S
3S
B
Reference
A
30
30
30
30
30
B
46
56
71
85
100
A
Hexagon nut (SUS304) and Liner cap
Liner
cap
Argon
welding
L1
Hexagon nut
(SUS304)
Argon
welding
L2 (50)
54
(Thermocouple)
PFA (Fluororesin) coated temperature sensors FT-100
FR-100 (Resistance Temperature Detector)
Temperature sensor with perfluoroalkoxy polymer resin coating (PFA) excels in chemical
and moisture resistance.
Measuring
Point
Measuring Point
Thermocouple : FT-100
Resistance Temperature Detector : FR-100
Specifications
FT-100 (Thermocouple)
Type
Thermocouple K, Class 1
FR-100 (Resistance Temperature Detector)
Type
Pt100, 3-wire system, Class A
Measuring range
Measuring range
0 to 200ºC
Do not condensate except for the protection tube
0 to 200ºC
Do not condensate except for the protection tube
Measuring accuracy ±2.5°C (Immersion length : 100mm or more)
Protection tube material PFA (fluororesin)
Acceptable radius 15mm (Except 90mm from tip)
for protection tube
bending
Lead wire diameter 1.0×1.6mm
±(0.15 + 0.002 | t |)°C (t:Measuring temperature)
Measuring accuracy Specified current : 2mA
(Immersion length : 100mm or more)
Protection tube material
PFA (fluororesin)
Lead wire diameter 1.7mm
Lead wire configure 0.1mm X 7
Lead wire configure 3.2mm X 1
Lead coating material PFA (fluororesin), Gray
Lead coating material PFA (fluororesin), Green
Application
Cleaning Chemicals
Gas Exhaust Pipe
Battery electrolyte
PFA coated
temperature sensor
PFA coated
temperature sensor
PFA coated
temperature sensor
Chemical liquid supplying device
Environmental test chambers
Thermal reaction
PFA coated
temperature
sensor
500
400
300
200
100
PFA coated
temperature sensor
55
(Thermocouple)
PFA (Fluororesin) coated temperature sensors FT-100
FR-100 (Resistance Temperature Detector)
External Dimensions
Unit : mm
Thermocouple
FT-100
Max.10000
Protection tube L1=250 to 5000 (*1)
15 (PFA filling)
15 (PFA filling)
80
4
4
4
2.5
18 (PFA filling)
50
No terminal lugs
(Terminal soldered)
(1.0X1.6)
55
(4)
Lead wire L2=500 to 9000 (*1)
+(Green)
- (White)
Protection tube
(PFA)
Specification
label
PFA coating lead wire
(0.32/1X2)
(Red)
Spade lugs
(Black) termination
+(Green)
- (White)
(Red)
*1: Total lead length of the protection tube length can be manufactured in 10000mm (10m) below.
+(Green)
Ring lugs
(Black) termination
- (White)
Resistance Temperature Detector
FR-100
Max.10000
Lead wire L2=500 to 9000 (*1)
Protection tube L1=250 to 5000 (*1)
15 (PFA filling)
15 (PFA filling)
80
50
1.7
4
4
4
12 (PFA filling)
4
55
A(Red)
B(White)
B(White)
Specification
label
No terminal lugs
(Terminal soldered)
Protection tube
(PFA)
*1: Total lead length of the protection tube length can be manufactured in 10000mm (10m) below.
PFA coating lead wire
(0.1/7×3)
Model Code
Thermocouple
FT-100
Specifications
Resistance Temperature Detector
FR-100
Model and Suffix Code
FT-100
- K- 42- A-
Thermocouple type Thermocouple K, Class 1
Diameter of
protection tube 4
Protection tube PFA (Fluororesin)
250mm
Length of
protection tube 500mm
(L1)
to (Each 500mm)
5000mm
*2
500mm
to (Each 500mm)
Lead wire length 5000mm
(L2)
5000mm
*2
to
(Each 1000mm)
9000mm
Lead wire
termination
No terminal lugs
*terminal soldered
Spade lugs for JIS standard
"M3" size screw
Spade lugs for JIS standard
"M4" size screw
Ring lugs for JIS standard
"M3" size screw
Ring lugs for JIS standard
"M4" size screw
- -AW
-
Resistance
temperature
detector type
Diameter of
protection tube
Protection tube
K
42
A
250
500
to
5000
W
Y3
Y4
FR-100
Pt100, Class A,
Middle temperature type
4
PFA (Fluororesin)
250mm
500mm
(L1)
to (Each 500mm)
5000mm
*3
500mm
to (Each 500mm)
Lead wire length 5000mm
(L2)
5000mm
*3
to
(Each 1000mm)
9000mm
Lead wire
No terminal lugs
termination
* terminal soldered
water cleaning &
Pure water cleaning Pure
Clean packing
Length of
protection tube
500
to
5000
5000
to
9000
Model and Suffix Code
Specifications
- DPA - 42- A -
- -AW
-
DPA
42
A
250
500
5000
500
to
5000
5000
to
9000
N
AW
*3 : Total length of Protection tube and lead wire can be up to 10000mm (10m).
R3
R4
water cleaning &
Pure water cleaning Pure
Clean packing
AW
*2 : Total length of Protection tube and lead wire can be up to 10000mm (10m).
56
Reference information
Thermocouple
(1) Thermocouple element type
Thermocouple elements K(CA), J(IC), T(CC), E(CRC), N, R, S, B are available. Please find the below chart and choose them according to
applications.
Thermocouple classes are standard as class 2 and an accurate type as class 1. (see the differences of temperature allowance section)
All standard types are class 2. (Only standard type for B is class 3)
JIS C1602-1995
Symbol (+) side
wire
(-) side
wire
Element
wire
diameter
(mm)
Operating temperature range (°C)
-200
0
200
400
600
800
1.00
K
(CA)
Chromel
Alumel
1000
850°C
900°C
3.20
1000°C
400°C
0.65
1.00
Iron
Constantan
450°C
500°C
1.60
2.30
550°C
3.20
T
(CC)
Copper
Constantan
600°C
0.32
200°C
0.65
200°C
250°C
1.00
300°C
1.60
450°C
0.65
E Chromel Constantan
(CRC)
500°C
1.00
550°C
1.60
600°C
2.30
3.20
700°C
850°C
0.65
950°C
1.00
Nicrosil
N
Nisil
1400
750°C
1.60
2.30
J
(IC)
1200
650°C
0.65
1050°C
1.60
1100°C
2.30
3.20
1200°C
Platinum
1400°C
0.50
Rhodium13% Platinum
1400°C
Platinum
0.50
S Platinum
Rhodium10%
*1 Platinum
Platinum
1500°C
B Rhodium30% Rhodium6% 0.50
°C
*1 Maximum operating temperature is normal operating temperature limit (temperature limit for continuous operation). For overheating use limitation (temperature limitation for a short time use for an unavoidable
situation), please find JIS standards (JIS C1602).
Consider the above chart only as a guide. Operating temperature limit is subject to change dependent upon the types of the protection tube.
For B type, measurement below 600°C is out of the tolerance range.
R
(2) Tolerance to temperature
Type
K
J
T
E
N
R,S
B
JIS C1602-1995
Class 1
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
Class 3
-40°C to +375°C
±1.5°C
+375°C to +1000°C
±0.004•|t|
-40°C to +375°C
±1.5°C
+375°C to +750°C
±0.004•|t|
-40°C to +333°C
±2.5°C
+333°C to +1200°C
±0.0075•|t|
-40°C to +333°C
±2.5°C
+333°C to +750°C
±0.0075•|t|
-167°C to +40°C
±2.5°C
-200°C to -167°C
±0.015•|t|
-40°C to +125°C
±0.5°C
+125°C to +350°C
±0.004•|t|
-40°C to +133°C
±1°C
+133°C to +350°C
±0.0075•|t|
-67°C to +40°C
±1°C
-200°C to -67°C
±0.015•|t|
-40°C to +375°C
±1.5°C
+375°C to +800°C
±0.004•|t|
-40°C to +333°C
±2.5°C
+333°C to +900°C
±0.0075•|t|
-167°C to +40°C
±2.5°C
-200°C to -167°C
±0.015•|t|
-40°C to +375°C
±1.5°C
+375°C to +1100°C
±0.004•|t|
-40°C to +333°C
±2.5°C
+333°C to +1200°C
±0.0075•|t|
-167°C to +40°C
±2.5°C
-200°C to -167°C
±0.015•|t|
0°C to +1100°C
±1°C
0°C to +600°C
±1.5°C
+600°C to +1600°C
±0.0025•|t|
Temperature range
Tolerance
Temperature range
Tolerance
Temperature range
Tolerance
• |t| is a value which represents regardless of + or - symbols of temperature (°C).
57
Class 2
+600°C to +1700°C
±0.0025•|t|
+600°C to +800°C
±4°C
+800°C to +1700°C
±0.005•|t|
Reference information
Resistance Temperature Detector
(1) Resistance Temperature Detector Type
Platinum RTD (resistance temperature detector) can be divided into either Pt100 or JPt100 (former). It is more often used for low temperature
applications than thermocouples, and has a high accuracy.
On the other hand, it is not suitable in a situation where the responsiveness and measurement of surface or tiny spaces are required.
Pt100 classes are either B as standard or A as accurate. For standard type, its class is B and its specified current is 2mA.
Elements L, M, and H meet JIS C1604-1997 whereas "P" doesn't.
Operating temperature range (°C)
Specifications
Type
-200
0
L
(Low Temperature
Type)
200
600
P
General type
(Middle Temperature
(3 to 4)
Pt100 Type)
JPt100
M
Sheathed type
(Middle Temperature General type(4.8 to 8)
Type)
220°C
350°C
Sheathed type
General type (5 to 8)
(High Temperature
Type)
800
100°C
Sheathed type
H
400
650°C
(Sheathed type or JPt100 : Up to 500°C)
Consider the above chart only as a guide.
(2) Tolerance to temperature
Class
Class A
Class B
JIS C 604-1997
Tolerance (°C)
±(0.15+0.002|t|)
±(0.3+0.005|t|)
• |t| is a value which represents regardless of + or symbols of temperature (°C).
Measuring
temperature (°C)
-200
-100
0
100
200
300
400
500
600
650
Tolerance Class A
(°C)
Class B
±0.55
±1.3
±0.35
±0.8
±0.15
±0.3
±0.35
±0.8
±0.55
±1.3
±0.75
±1.8
±0.95
±2.3
±1.15
±2.8
±1.35
±3.3
±1.45
±3.6
700
800
850
±3.8
±4.3
±4.6
● Protection Tube
SUS304, SUS316(for sheath), and Nicrobell are available as materials for the protection tube for standard type. It is available to select its
material based on measured objects and measurement conditions.
<Normal operating temperature limits> <Sheathed type>
Diameter
Thermocouple Protection tube
K
J
T
N
SUS316
SUS310S
Inconel
Nicrobell
SUS316
SUS316
Nicrobell
JIS C 1605,(Nicrobell is out of JIS standard)
1.0
1.6
3.2
4.8
6.4
8.0
650°C
650°C
650°C
650°C
750°C
750°C
900°C
450°C
300°C
1000°C
450°C
300°C
1000°C
1100°C
650°C
350°C
1100°C
800°C
800°C
900°C
1100°C
750°C
350°C
1100°C
800°C
800°C
1000°C
1150°C
750°C
350°C
1150°C
900°C
900°C
1050°C
1200°C
750°C
350°C
1200°C
(1) Special Protection Tube
Metal protection tube
Material
Sandvik P4
(SUH446)
Operating temperature
for regular use (°C)
Maximum
temperature (°C)
1000°C
1200°C
Titanium
250°C
500°C
Cast Iron
700°C
800°C
180°C
200°C
Fluor resin coating
Features
Excellent heat resistance and contained 27% chromium steel. Excellent salt-bath, melted metal,
and acid resistance under high temperature.
It can be used for sulfate containing reducing flame.
Extremely excellent corrosion resistance, however this feature will be fragile under high
temperature by oxidization.
Extreme mechanical resistance.
Fluor resin (FEP) coating with SUS316 sheath. Incredible chemical resistance under low
temperature.
Non-metal protection tube
Material
Operating temperature
for regular use (°C)
Maximum
temperature (°C)
600°C
Hard glass
500°C
Silica glass
1000°C
High alumina
Ceramic tube
Pure sintering
alumina
Zirconia
1400°C
1500°C
1450°C
1550°C
1700°C
1900°C
1900°C
2100°C
Silicon carbide
1500°C
1700°C
Silicon nitride
1200°C
1600°C
Ceramic JIS Special
1600°C
Ceramic JIS Type 1
Ceramic JIS Type 2
1500°C
1400°C
Features
Heatproof temperature limit is low. Fragile to thermal and mechanical shock and has a
resistance to alkaline and acid.
Has a resistance to sudden cooling and heating, Meanwhile, its strength is small. Vulnerable to
alkaline, and resistant to acidity.
Airtightness is deteriorated in hydrogen and reducing atmosphere.
Incredible air proof. Melted metal and combustion gas resistance. Vulnerable to metallic oxide
and alkaline.
Incredible air proof. It is a neutral refractory. Melted metal, glass, and leady slag resistant.
Vulnerable to thermal shock.
It is thermal resistant and air proof. Excellent resistance to corrosion from glass and metallic slag.
Good electrical and thermal conductivity. Withstand sudden heating, cooling, and oxidizing for its
massive thermal strengthens.
Excellent corrosion resistance to non-ferrous metals. Its thermal shock resistance is also excellent.
Available to be stable measurement in a oxidized, reducing atmosphere, and high vacuum
ambient environment.
Excellent thermal and corrosion resistance. Good thermal characteristics.
Less thermal softening and good thermal shock resistant.
• Temperature for regular use and maximum temperature vary dependent upon the diameter of the protection tube.
58
Reference information
Lead Wire : Compensation cable (Thermocouple), Copper wire (Resistance temperature detector)
Compensation cable is used for thermocouple. Copper wire is used for RTD. There are other types of the lead wire such as glass fiber (EXB),
vinyl coating(EXD) and so on. Please specify its type.
To use the copper lead wire for thermocouple result in inaccurate temperature measurement. Characteristics of lead wire should be same as
the element of thermocouple.
Copper lead wire is used for RTD. Pay attention for wiring due to three-wires. Make sure that a resistance value of each wire is balanced.
Below chart is the plain specification for each compensation lead wire.
JIS C 1610-1995
Type Applications
Standard
KCC-G
K
J
For heatresistive
KCB-H
Standard
JX-G
For heatresistive
JX-H
Standard
TX-G
For heatresistive
TX-H
Standard
EX-G
*1
Composition of core
Code (JIS)
Contact point
Shearh
compensation
Material *2 Color temperature (°C)
(+) Side
(-) Side
Copper
0.3 × 7
Alloy of Copper and Nichel
0.3 × 7
Vinyl
Iron
0.3 × 7
Alloy of Copper and Nichel
0.3 × 7
Fiberglass
Iron
0.3 × 7
Alloy of Copper and Nichel
0.3 × 7
Copper
0.3 × 7
Alloy of Copper and Nichel
0.3 × 7
0 to 100
Blue
NX-G
Yellow
-25 to 200
±140
Brown
-25 to 100
±60
Purple
-25 to 200
±200
Pink
-25 to 200
±100
Fiberglass
Vinyl
Vinyl
Alloy of Nichel and Chrome Alloy of Copper and Nichel
0.3 × 7
0.3 × 7
Standard
±100
0 to 150
Fiberglass
E
EX-H
*3
Vinyl
T
For heatresistive
Error
(μV)
Fiberglass
Vinyl
Alloy of Nichel and Chrome Alloy of Nichel and Silicon
0.3 × 7
0.3 × 7
N
For heatresistive
NX-H
Fiberglass
Standard
RCM-G
Vinyl
For heatresistive
RCM-H
Standard
SCA-G
Vinyl
For heatresistive
SCA-H
Fiberglass
Standard
BC-G
R
Alloy of Copper and Nichel
0.3 × 7
Copper
0.3 × 7
Fiberglass
Black
0 to 100
Gray
0 to 100
±30
S
B
Copper
0.3 × 7
Copper
0.3 × 7
Vinyl
*4
*1:0.65 ×4 wires is available for both (+) and (-).
*2:Codes and types for external material (Coating) is based on JIS. Please refer to the below chart for the other types.
*3:It is concerinig temperature of the junction with element and compensation cable.
*4:Tolerance value is not specified since a material for + core wire and - core wire is identical.
Compensation cable
JIS C 1610-1995 (EXE, EXF is out of JIS standard)
Composition of Compensation cable
Insulation
Sheath
Core wire
Operating temperature
Details
Code
EXA
For heat-resistive, Fiberglass with stainless steel
EXB
For heat-resistive, Fiberglass
EXC
For standard, PVC (polyvinyl chloride) with copper wire braided
EXD
For standard, PVC (polyvinyl chloride)
EXE
For heat-resistive, Silicone rubber
EXF
For heat-resistive, Fluorocarbon polymers (FEP)
0 to 150°C
-20 to +90°C
(KCB,RCA,SCA,BC : 0 to 90°C)
-55 to +180°C
0 to 200°C
Responsiveness of sensors
It takes a certain time for measuring junction of thermocouple or element of RTD to reach the same temperature with measuring object. The
shorter the pipe is, the faster the response is. Meanwhile mechanical resistance becomes weaken. It is important to select a sensor according to
purpose and condition. Please refer to following chart as a guide.
Response time (Atmospheric temperature to boiling water)
Reference values
Type
Thermocouple
(General type)
Sheathed
Thermocouple
59
3.2
5.0
1.0
1.6
3.2
4.8
8.0
63.2%
95.0%
0.3 sec 0.9 sec
0.8 sec 2.6 sec
0.05 sec 0.2 sec
0.15 sec 0.6 sec
0.5 sec 1.8 sec
1.0 sec 2.6 sec
2.7 sec 10.7 sec
Reference values
Type
Resistance
temperature
detector
(General type)
Sheathed
resistance
temperature
detector
(General type)
3.0
5.0
6.0
8.0
3.2
4.8
8.0
63.2%
95.0%
3.6 sec 9.2 sec
5.5 sec
15 sec
7.1 sec
19 sec
11.8 sec
33 sec
3.2 sec 8.7 sec
4.2 sec 11.5 sec
8.7 sec
21 sec
Temperature sensor specification check sheet
(For General type and Sheathed type)
Please make a copy of this specification check sheet and send it to our distributors.
Check Specifications
Check Item Reference
page
Protection
tube type
Page 3 to
Page 4
Type
Page 11 to
Page 27
(Thermocouple)
Page 45 to
Page 54
(Resistance
temperature
detector)
Operating
temperature
General type
Sheathed type
NICROBELL sheathed type
Thermocouple
K
J
T
E
N
R
B
S
PLII
W5Re/W26Re
Grounded (Standard)
Ungrounded
Exposed
Single element (Standard)
Double element
Class 2 (Standard)
Class 1
Class 3 (Type B)
Resistance Temperature Detector (RTD)
Single element (Standard)
Double element
Class B (Standard)
Class A
Grounded (Standard)
Ungrounded
Normal :
°C
°C
Maximum :
90° bend type
(Please check one out of 2 from the following pictures)
Straight type (Please check one out of 6 from the following pictures)
Length of protection tube (L1)
Diameter of protection tube (d)
mm
L1
d
d
L1
d
d
L1
L2
L1
L1
With spring loaded
d
Page 45 to
Page 54
(Resistance
temperature
detector)

L2
L1
Page 11 to
Page 27
(Thermocouple)
d
Shape
d
Diameter of protection tube (d)
L1
mm
mm
Length of protection tube (L1)
(L2)

L1
d
With spring loaded
Other: please draw external view
With spring loaded
Optional
With stainless flexible lead wire
Fluor resin coating
Other
No bracket
Fixed flange
JIS
K A or
Mounting
Bracket
B
Page 6
G (P.F)
Compression fitting
Taper screw
R(PT)
Lead
protection
Page 59
Lead wire
length
Page 11 to
Page 54
Lead wire
termination
Fixed nipple (nut) (Check either parallel or taper screw)
Rotary nipple (nut) (Check either parallel or taper screw)
Parallel screw
G (PF)
Taper screw
R (PT)
Page 7 to
Page 8
Other requests or
environments of
usage
Measuring object
or application
(for reference)
Fiberglass with stainless steel
PVC (polyvinyl chloride)
R (P.T)
Other
Fiberglass
Silicone rubber
PVC (polyvinyl chloride) with copper wire braided
Fluorocarbon polymers (FEP)
mm
No terminal lugs *terminal soldered
Spade lugs (M3 size) Ring lugs (M4 size)
Metal connector
Plug
Thermocouple connector
Receptacle
Plug
Other
Jack
Company Name
Name
Country
Address
E-mail Address
Phone Number
60
Safety
Warning
• This product is intended for use with industrial machines, test and measuring
equipment. It is not designed for use with medical equipment.
• If it is possible that an accident may occur as a result of the failure of the product or
some other abnormality, an appropriate independent protection device must be
installed.
Caution for the export trade
All transactions must comply with laws, regulations, and treaties.
Caution for imitated products
As products imitating our product now appear on the market, be careful that you don't
purchase these imitated products. We will not warrant such products nor bear the
responsibility for any damage and/or accident caused by their use.
R
(RIKA KOGYO CO.,LTD)
HEAD OFFICE : 16-6, KUGAHARA 5 CHOME OHTA-KU TOKYO 146-8515 JAPAN
PHONE : 03-3751-9799 ( +81 3 3751 9799 )
Email :
info@rkcinst.co.jp
FAX :
03-3751-8585 ( +81 3 3751 8585 )
http://www.rkcinst.com/
CSEN10-E