Temperature Sensors • Thermocouples • Resistance Temperature Detectors R Precautions for Temperature Sensor Insertion length To measure the temperature accurately, the temperature sensor should be thermally balanced against the measuring object. If the actual insertion length of the protection tube is short, the temperature sensor will be thermally affected from the surrounding area and cause an error. The required insertion length will differ depending on the measuring object, protection tube, etc. Install the temperature sensor so that the insertion length will be longer than the values shown in Table 1. Table 1 : Insertion of thermocouple (Melt protection tube) · Reference value Measuring object Insertion length Liquid More than 5 times of protection tube diameter More than 10 times of protection tube diameter Gas Insertion length Protection tube diameter · Resistance temperature detector should be inserted more deeply. (Approx 2 times of thermocouple) WIRING Check polarity when wiring for the following. Wrong polarity causes measurement error. · Connect temperature sensors to element wires, compensation cables, connectors or terminal blocks. Use appropriate compensation cables to joint between terminal boxes and instruments when thermocouple is used. Use copper wire cables when resistance temperature detector used. When connecting the sensor to a terminal block or a connector, make sure all connections are properly made. If screws are not tightened firmly enough, it may cause a loose contact. A burr on the cable may cause short circuit. Consider heat resistance of cable. Contacting cable to heat source or putting it closer causes insulation failure, short-circuit or cable break. Double-element type thermocouple When thermocouple is double-element type, measurement point is bonded together regardless of grounded junction or ungrounded junction. No need to divide into plus polar and minus polar in each element. Specify when ordering if measurement points need to be bonded individually. HANDLING Connect to specified terminals of sensor inputs when connecting temperature sensors to instruments. Connecting to power supply cause burn, fire or explosion. Do not install sensors: Near a high-voltage power supply. At places where high-voltage could be applied to them due to electric leakage or other causes. Avoid quick heating and cooling. It causes failure or damage due to heating shock. (Especially pay attention to it in case of using Ceramic Thermocouple Protection Tube .) Do not touch temperature sensors till those temperature return to ambient temperature when temperature sensors are used at high or low temperature. It causes burn injury or cold injury. Confirm that temperature sensors work well after installment. MgO sheathed temperature sensor Do not bend repeatedly though it is able to bend in the range of 5 times radius of sensor’s diameter. It causes failure or damage. · Bending work can be specified in the range of three-times radius when ordering. Do not bend at the point within 100mm from the tip of measuring points since resistance element is mounted at the tip. If the ordered protection tube is long, it may be shipped coiled. To uncoil the tube, carefully restore it by uncoiling it into the reverse direction of coiling. (Don’t pull the tube with force while it is still in coil form) Temperature sensor with sleeve Don’t bend the cable sharply near the sleeve fixed with resin. Do not use the sensor where the temperature of the sleeve parts exceeds its high limit of operating temperature. It causes disconnection, connection failure, or short-circuit. Sheath thermocouples can be ordered with a minimum protection tube length of 50mm. However, with a short protection tube, the temperature on the sleeve may be affected by the heat source and need longer time to get stabilized. Temperature error may be also larger. It is recommended to order the protection tube with a longer length considering the operating temperature. Temperature sensor with lead wire Do not forcibly pull the lead wire, it may cause connection failure or short-circuit. When installing or removing sensors using stainless steel shield wire, handle with care to prevent a break of the thin shield wire. Do not bend the lead wire or slide spring excessively or repeatedly. Protect your hands with gloves to avoid hurting by shielded cable. Fluorine resin coated temperature sensor Fluorine resin coated temperature is sexcels in chemical resistance. However some chemicals penetrate into the internal of the sensor. Use it within the range of the specifications. Temperature sensor with porcelain protection pipe Porcelain protection pipe is easy to be broken. Do not apply an excessive force to the part of protection pipe. INSPECTION IN USING Inspect regularly as follows. · Inspect damaged condition of protection pipe. · Remove extraneous matter such as soot, dust or sludge. · Tighten screw at junction part. · Remove water drops or dew condensation · Inspect insulation resistance. (except grounded junction sensor) · Other usage environment. · Inspect accuracy regularly. DISPOSAL Dispose of sensors in compliance with the law, regulation, and any other applicable rules at the place where the sensor is used. NOTICE RKC is not responsible for any damage or injury that is caused as a result of using this sensor, sensor failure or indirect damage. RKC is not responsible for any damage and/or injury resulting from the use of sensors made by imitating this instrument. Every effort has been made to ensure accuracy of all information contained herein. RKC makes no warranty expressed or implied, with respect to the accuracy of the information. The information in this manual is subject to change without prior notice. 1 CONTENTS 1) Precautions for temperature Sensor 1 Screwed tip thermocouples T-230 2) Contents 2 Fixing screw type thermocouples for surface temperature measurement T-240 Ring type thermocouples for surface temperature measurement T-250 Thermocouples for resin temperature T-260 3) Temperature sensor list 3-4 4) Installation example 5 5) Mounting brackets 6 6) Lead wire termination • Terminal head • Measuring junction • Tip processing 7-8 7) Thermocouple connectors 9-10 8) Thermocouples • General purpose thermocouples 11-36 11-19 Spring loaded type thermocouples T-100,T-110 12 Sleeve type thermocouplesT-101,T-111 13 No sleeve type thermocouples T-102 14 Terminal head type thermocouples T-30,T-35 15 Exposed terminal head type thermocouples T-80,T-85 16 Metal connector type thermocouples T-90 17 Noble Metal type thermocouples T-30,T-35 18 Noble Metal type thermocouplesT-80,T-85 19 • Sheathed type thermocouples 20-24 Sleeve type thermocouples T-101S,T-111S 20 Terminal head type thermocouples T-30S,T-35S 21 Thermocouple connector type thermocouples T-70S,T-75S 22 Exposed terminal head type thermocouples T-80S,T-85S 23 Metal connector type thermocouples T-90S 24 • Nicrobell sheathed thermocouples 25-27 Sleeve type thermocouples T-101N,T-111N 26 Terminal head type thermocouples T-30N,T-35N 27 Thermocouples for resin temperature (Zero-heat-flow method) T-270Z Adhesive and exposed tip type temperature sensors ST-50,ST-51 Temperature sensors for extremely small surface ST-55,ST-56 Thermocouple type non-contact temperature sensors ST-100 Thermocouple type non-contact temperature sensors ST-100K Rotationary roll surface temperature measuring sensors JBS-3898 34 34 35 36 36 37-38 39-41 42 43 44 45-54 9) Resitance temperature detectors • General purpose resistance temperature detectors 45-49 Sleeve type resistance temperature detectors R-101,R-111 No sleeve type resistance temperature detectors R-102 Terminal head type resistance temperature detectors R-30,R-35 Metal connector type resistance temperature detectors R-90 • Sheathed type resistance temperature detectors Sleeve type resistance temperature detectors R-101,R-111S 46 47 48 49 50-54 50 Terminal head type resistance temperature detectors 51 R-30S,R-35S Metal connector type resistance temperature detectors 52 R-90S Sanitary type sheathed resistance temperature detectors 53-54 R-31S/R-36S/R-31RS/R-36RS 10) PFA (Fluororesin) coated temperature sensors • Thermocouples for various applications Bayonet type (With spring loaded) thermocouples T-200,T-210 Bayonet type (Sleeve type) thermocouples T-201,T-211 Bayonet type (Sleeve type) sheathed thermocouples T-201S,T-211S Bayonet type sheathed thermocouples for high temperature (Variable insertion length type) T-202SH,T-212SH Bayonet type thermocouples (Variable insertion length type) T-220,T-221 28-36 29 30 31 Thermocpuple/Resistance temperature detectors FT-100,FR-100 11) Reference information Thermocouples Resistance temperature detectors Protection tubes Lead wires Compensation lead wires Responsiveness of sensors 32 12) Temperature sensor specification check sheet 33 13) Calibration service for temperature sensors 55-56 57-59 57 58 59 59 59 59 60 61-62 2 Temperature Sensor List General Purpose Temperature Sensors Measuring Range Type -200 0 200 400 600 800 1000 1200 1400 1600 T Type 200°C(250°C) K,J Type Thermocouples 300°C(400°C) Measuring range differ to protection tube diameter, etc. Appearance Features T-100/T-110 T-110 is protection tube 90° bend type. Standard type. The diameter of protection tube is either 5 or 6. Reference page 12 T-101/T-111 T Type T-111 is protection tube 90° bend type. 250°C(300°C) T-102 J Type 450°C(550°C) T-30/35 Thermocouples E Type 500°C(550°C) Standard type. A variety of kinds are available. 13 to 17 Temperature sensor which is suitable for high temperature measurement. Platinum is used for element. 18 to 19 Thin protection pipe is available. Faster responsiveness. Excellent Vibration and shock resistance. 20 to 24 High stability, and excellent heat and environmental resistance. Capable of high temperature measurement. Excellent Vibration and shock resistance. 25 to 27 High accuracy and stability. Inexpensive compared with the MgO sheathed RTDs. 45 to 49 Excellent vibration proof and shock resistance compared with the other standard types of thermocouples. 50 to 52 Sanitary designed sensor protected from foreign materials and microbiological contamination. Suitable for usage in food, beverage, chemical processes without concern of contamination. 53 to 54 Chemical and humid resistant PFA coated sensor. PFA coated from the sensing point to the lead wire. 55 to 56 T-80/T-85 K Type T-90 750°C(950°C) T-30/T-35 R,S Type 1400°C(1600°C) B Type Noble Metal Thermocouples 1500°C(1700°C) T-80 T-101S/T-111S T Type 350°C T-101S is protection tube 90° bend type. T-30S/T-35S J Type Sheathed Thermocouples E Type T-70S/T-75S K 750°C 800°C T-80S/T-85S K Type 900°C T-90S T-101N/T-111N K,N Type 1200°C NICROBELL Sheathed Thermocouples T-111N is protection tube 90° bend type. T-30N/T-35N R-101/R-111 R-111 is protection tube 90° bend type. Pt100 Type 650°C JPt100 Type Resistance Temperature Detectors R-102 R-30/35 500°C R-90 R-101/R-111S Pt100/Jpt100 Type 500°C Sheathed Resistance Temperature Detectors R-30S/35S R-90S R-31S/36S Pt100/Jpt100 Type 200°C Pt100 Type 200°C Sanitary type Sheathed Resistance Temperature Detectors PFA (Fluororesin) coated temperature sensors R-31RS/36RS FT-100 (Thermocouple, Resistance FR-100 Temperature Detectors) • For thermocouple, value is normal operating temperature limit while that of in ( ) is maximum operating temperature limit. For RTDs, it is operating temperature. 3 Temperature sensors for various applications Measuring Range Type • Usages -200 0 Appearance 200 400 600 800 1000 Reference page Features T-200/T-210 T Type 200°C(250°C) The tip is going to be pressure welded to the measured object by mounting bracket. T-201/T-211 29 to 31 T-201S/T-211S(Sheathed Thermocouple) Suitable for measurement of hot runners, dies and moulds. T-210 is protection tube 90° bend type. K,J Type 300°C(400°C) Bayonet type thermocouples [Applications] Plastic molding Cylinder Molding die Hot runner K Type 550°C T Type 200°C(250°C) K,J Type 300°C(400°C) T-211(S) is protection tube 90° bend type. Thermocouple with bayonet. Length can be easily adjusted. T-202HS/T-212HS Easy mounting is possible by moving the bayonet cap dependent upon the T-212HS is protection tube 90° bend type. insertion length. Thermocouple with bayonet. Length can T-220 be easily adjusted. Decide the position of the mounting bracket dependent upon insertion length and fix the spring by fixed screw. Thermocouple with bayonet. Length can T-221 be easily adjusted. Easy mounting is possible by moving the bayonet cap dependent upon the insertion length. Sheathed Thermocouple for High Temperature Screwed Tip Thermocouples T Type 200°C(250°C) K,J Type 300°C(400°C) T Type 200°C(250°C) K,J Type 300°C(400°C) T Type 200°C(250°C) [Applications] T-230 Plastic molding Cylinder Molding die Hot runner Fixing screw type thermocouples for surface temperature measurement Ring type thermocouples for surface temperature measurement T-240 300°C(400°C) K,J Type 400°C Plastic molding Cylinder Nozzle Pipe shaped objects Thermocouples for Resin Temperature T-260 [Applications] Melting resin temperature of Extruder K,J Type 400°C Thermocouples for Resin Temperature Melting resin temperature of Extruder K Type 300°C K Type 300°C [Applications] 500°C Temperature Sensors for Extremely Small Surface ST-55 [Applications] ST-56 Ceramic coating type Surface of electronic parts ST-100 Thermocouple Type Non-Contacting Temperature Sensors K Type 300°C ST-100K/K1 K Type 200°C(260°C) K Type 300°C 34 Fix the sensor at a 4.5 fixed screw hole of the tip with a screw. Suitable for temperature measurement for the tiny spaces. 34 Suitable for temperature measurement for the pipe shaped objects and the surface of the nozzles. 35 Capable of measurement of the molten resin temperature, such as the inside of the extruder. M16 screw is cut and its tip directly touches to the melting resin. 36 By utilizing ZHF (zero-heat-flow) method, it eliminates thermal disturbances and temperature errors between the tip and the outside case and realizes more precise temperature measurement of the melting resin. 36 ST-100 37 to 38 A fine thermocouple enables measurement of a fine surface or a surface 39 to 41 with small thermal capacity such as SMT parts. ST-100K/ST-100K1 Capable of surface temperature measurement of the rotating objects 42 to 43 such as rollers and sheets without direct contact. [Applications] Surface temperature of Roller and Rotationary objects Rotationary Roll Surface Temperature Measuring Sensors The tip is M6 size (M8 size is also available) rotary screw. Internal screws will be threaded in the fitting point. *M6, M8 is based on JIS Standard. An adhesive surface at the tip allows easy attachment and measurement of the surface temperature. Exposed type is also available. ST-50/ST-51 Surface of electronic parts Fluorine resin coating type K Type 33 *M16 is based JIS Standard. T-270Z [Applications] Adhesive and exposed tip type temperature sensors 33 T-250 [Applications] K,J Type 32 JBS-3898 [Applications] Capable of surface temperature measurement of the rotating objects such as rollers and sheets with direct contact. 44 Rotationary Roll Surface • Temperature value : Normal operating temperature limits, ( ) : Maximum operating temperature limits Normal operating temperature limits and maximum operating temperature limits Normal operating temperature limit is a temperature limit of sensors' continuous use in the air. It is a reference temperature that ±0.75% of thermo electromotive force might not change with 10,000 hours of its successive use. • For R, B, and S type, it is a reference temperature that ±0.5% of thermo electromotive force might not change with 2,000 hours of its successive use. Maximum operating temperature limit is a limit of allowable temperature for short-term used in unavoidable situations. It is a reference temperature that ±0.75% of thermo electromotive force might not change with 250 hours of successive use. • For R, B, and S type, it is a reference temperature that ±0.5% of thermo electromotive force might not change with 50 hours of its continuous use. (JIS C1602-1995) 4 Installation example Fixed nipple (nut), Code : A The insertion length is fixed (specify when you order) as for the nipple is fixed on the protection tube. Screw will be fit by welding at the fitting side or threading. Screw types will be either tapered or parallel one. Rotary nipple (nut), Code : B The insertion length is fixed (specify when you order) as for the stopper of nipple which is fixed on the protection tube. Screw will be fit by welding or threading at the fitting side. Easy fitting is realized because only the screw rotates. There is no air tightness. Available screw types are taper and parallel. Fixed flange (Code : C) The insertion length is fixed (specify when you order) as for the flange is welded to the protection tube. The flange will be welded to the fitting side in advance, and fixing it with a bolt. Sliding flange The insertion length will be decided arbitrarily. The flange will be fixed at the fitting part with a bolt, and fastened with screws. There is no air proof. Screw Compression fitting (Code : E) The insertion length is freely adjustable. Weld a screw to the mounting side or thread a hole for it. Screw the mounting bracket into the hole. Determine the length and tighten the nut to fix Bayonet type thermocouple Thread a hole in advance on the mounting side and screw the holder into the hole. Hang the bayonet cap on the holder and fix it. Temperature measuring junction is constantly pressed to the measuring point with the spring force. L shape type Use an L-shaped type where a straight type is hard to install or where lead wire/terminal box may be corroded or thermally affected. 5 Bayonet Holder Mounting Brackets How to specify the length (L) of the protection tube with the mounting bracket. For the sensor with fixed flange or fixed nipple, specify length (L) by referring length of under the screw or under the flange. If a space is required between the mounting bracket and the sleeve or between the mounting bracket and the terminal box, please specify it as well. With fixed flange For L shape sensors, mounting bracket will be installed as the below picture. * Please contact with our distributors in case mounting bracket is needed to install to other places. L shape sensor For the sensor with compression fitting, specify length (L) by referring the terminal box and the sleeve as the same order way without mounting bracket. With nipple L1 L1 L1 50 L1 Flange ● JIS • FF flange (Fixed type) <Material : SUS304> Unit:mm Dimension of Flange Bolt Hole h Number of Hole 12 12 12 12 15 15 15 19 15 15 15 19 19 19 19 19 19 19 19 23 23 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 8 4 4 8 8 8 * A collar will be equipped between the fixed flange and the terminal box if diameter of the protection pipe is under φ10, Collar 22 50 t B D t A C 3/8 10 9 75 55 1/2 15 80 9 60 3/4 20 85 10 65 JIS 5K 25 1 10 95 75 h Flange 40 11/2 120 12 95 50 2 14 130 105 65 21/2 155 14 130 C 80 3 180 14 145 D 3/8 10 12 90 65 1/2 15 12 95 70 3/4 20 100 14 75 25 1 125 14 JIS 10K 90 Flange 40 11/2 140 16 105 50 2 16 155 120 65 21/2 175 18 140 80 3 185 18 150 25 1 16 125 90 40 11/2 140 18 105 JIS 20K 50 2 18 155 Flange 120 65 21/2 175 20 140 80 3 22 200 160 How to Specify For JIS 5K flange, pleasse specify as JIS5K (fixed) flange 10A or specify as 3/8B. L1 Name of Size • RF flange is also available. Please specify when you order. AxB L 1 H R (P.T) AxB 10 12 15 18 22 22 or less 22 6 6 7 10 16 16 14×16.2 17×19.6 21×24.2 26×30 32×37 41×47.3 T-220 Holder Available model (Inner diameter d=5.2mm) : T-220,221,202SH,212SH T-200 Holder Available model (Inner diameter d=7.2mm) : T-200,201,210,211 4 3 R (PT)1/8 2 H 10 L How to Specify Please specify as G or PF (parallel nipple) 1/8 • R or PT(taper nipple) 1/8. • Parallel nipple • taper nipple are both applied to the fixed and rotary nipples. 3 12 G (P.F) Taper Screw L 3 Diameter of G(PF)/R(PT) protection tube 1/8 6 or less 1/4 8 or less 3/8 10 or less 1/2 12 or less 3/4 16 or less H +0.2 0 Parallel Screw L Holder Unit:mm d Nipple (nut) <Material : SUS304> Screw : R(PT)1/8 L=32,40,62 (Please specify when you order) • Different types of screws are also available. AxB Compression Fitting <Fastening Ring Material : SUS304> Push screw type Cap nut type L L A L1 A B L2 L3 L1 Unit:mm Diameter of R(PT) protection tube 1/8 1/4 1.6 3.2 4.8 3.2 4.8 6.4 8.0 L L1 L2 L3 33 33 35 37 38 38 41 10 10 10 14 14 14 14 6 6 6 6 6 6 6 12 12 14 12 14 14 16 A B 12×13.7 12×13.7 12×13.7 12×13.7 12×13.7 14×16.2 14×16.2 12×13.7 14×16.2 14×16.2 14×16.2 14×16.2 17×19.6 17×19.6 of R(PT) Diameter protection tube 3.2 4.8 3/8 6.4 8.0 3.2 4.8 1/2 6.4 8.0 L2 B L3 Unit:mm L L1 L2 L3 39 40 45 44 43 44 49 48 16 16 16 16 20 20 20 20 15 15 19 19 15 15 19 19 5 5 5 5 5 5 5 5 A B 22×25.4 22×25.4 22×25.4 22×25.4 24×27.7 24×27.7 24×27.7 24×27.7 14×16.2 14×16.2 17×19.6 17×19.6 14×16.2 14×16.2 17×19.6 17×19.6 6 Lead wire termination Lead wire termination For lead wire termination (compensation wire and copper wire), Spade lugs, Ring lugs, connector, and TC type connector are available. We also can provide requested termination type. Spade lugs Ring lugs JIS standard "M3" size screw Thermocouple connectors JIS standard "M4" size screw Composition of the leadwire will be as follows [(plug) + (clamp) + (jack)] when TC connector [code : TE] is specified. For other types and combinations, please refer to p.10. Jack 4 20 V1.25-B3A V1.25-M4 (Manufactured by J.S.T MFG CO., LTD.) 15 30 36.4 12.4 20 25.4 4.7 6.5 3.2 5.8 4.3 Plug (Manufactured by J.S.T MFG CO., LTD.) Model Code : CSP02- Model Code : CSP01- Metal connectors Composition of the lead wire will be [(plug) + (receptacle)] when metal connector is specified as termination. * Connector is manufactured by Sanwa Connector Laboratory Co., Ltd.. Composision of the lead wire will be (adaptor) + (plug) when adaptor is specified as termination. * Connector is manufactured by Sanwa Connector laboratory Co., Ltd.. Metal connector manufactured by Nanaboshi Electric Mfg. Co., Ltd. is also available. Manufactured by Sanwa Connector Laboratory Co., Ltd. (Standard) Receptacle M18P:1 Adaptor M18P:1 Panel Cutout 1 4 11 42 7 3-3.2 3-3.2 23 +0.3 0 18 8 21 14.5 16 32 14.5 14 21 18 8 5 6. 2 M18P:1 2 4 Plug 43 Specification Model Code Specification Model Code Specification Model Code Thermocouple (Single element) Thermocouple (Double element) Resistance Temperature Detector (Single element) Resistance Temperature Detector (Double element) SCK-1602-P SCK-1604-P SCK-1603-P Thermocouple (Single element) Thermocouple (Double element) Resistance Temperature Detector (Single element) Resistance Temperature Detector (Double element) SCK-1602-R SCK-1604-R SCK-1603-R Thermocouple (Single element) Thermocouple (Double element) Resistance Temperature Detector (Single element) Resistance Temperature Detector (Double element) SCK-1602-A SCK-1604-A SCK-1603-A 4 1 2 SCK-1606-A Adaptor M18P:1 Panel Cutout 4 Manufactured by Nanaboshi Electric Mfg. Co., Ltd. Receptacle Plug M18P:1 M18P:1 11.5 SCK-1606-R 2 SCK-1606-P Specification 8 26 Specification Thermocouple (Double element) Resistance Temperature Detector (Double element) 28.5 22 Model Code Specification NCS-254-P NCS-256-P Thermocouple (Double element) Resistance Temperature Detector (Double element) Model Code NCS-254-R NCS-256-R Connector has 2 types. One is "Female connector type (standard), the other one is "Male connector type". Female connector type (standard) Male connector type Specification Specification Socket insert plug Pin insert plug Pin insert receptacle Pin insert adaptor 2 1 7 + Specification Model Code Thermocouple (Double element) Resistance Temperature Detector (Double element) NCS-254-Ad NCS-256-Ad Plug Socket insert receptacle Pin insert adaptor Pin numbers and polarity (standard) - 57 3-M3 or 3.4 ±0.2 3-M3 (Double - + element) 4 1 3 + - 2 20 4 3 3 4 25 22 42 28.5 21.4 11.5 50 (Single element) Adaptor M25x1.25 Panel Cutout M25x1.25 Model Code Thermocouple (Single element) NCS-162-Ad-CH Resistance Temperature Detector NCS-163-Ad-CH (Single element) Receptacle 13 8.5 Model Code 6 2 22.3 M25x1.25 22.9 14.8 Specification NCS-162-R-CH Thermocouple (Single element) Resistance Temperature Detector NCS-163-R-CH (Single element) (There are some changes in codes dependent upon production companies. For Sanwa Connector Laboratory Co., Ltd., NCF will be SCH. For Nanaboshi Electric Mfg. Co., Ltd., plugged end connector will be P to PM, receptacle will be R to RF, and adaptor will be Ad to AdF. 23.5 Model Code 42.5 11.5 Specification 3-M3 or 3.4 ±0.2 3-M3 23 NCS-162-P-CH Thermocouple (Single element) Resistance Temperature Detector NCS-163-P-CH (Single element) Plug 16 14.8 32 21.5 20 8.5 14.3 7 7.3 44 Pin insert Socket insert (Female connector) (Male connector) Terminal head • Measuring junction • Tip processing • Lead wire termination Terminal head Enclosed-terminal 30 type Terminal Head Enclosed-terminal 35 type Terminal Head (10) (6) Lead wire output port (82) Aluminum die cast PF3/8 • Thermocouple : 2 Number of Terminals • Resistance temperature detector : 3 Terminal board Material Steatite porcelain Available Metal 3 to 10 diameter 6 to 10 of protection tube Non-metal Coating Color Silver (43) (17) (53) (22) PF1/2 Lead wire output port Aluminum die cast PF1/2 • Thermocouple : 2, 4 • Resistance temperature detector : 3, 6 Steatite porcelain 4.8 to 22 6 to 17 Silver Material Lead wire output port Specifications (70) (48) (38) (88) (65) 6) PF3/8 (60) Exposed terminal 85 type Terminal Head 78 (5 Appearance Unit:mm Exposed terminal 80 type Terminal Head (43) Name Phenol resin Exposed terminal Phenol resin Exposed terminal Thermocouple : 2 Thermocouple : 2 Phenol resin 3 to 10 6 to 10 Black Phenol resin 4.8 to 22 6 to 17 Black Measuring junction Ungrounded (Example of Thermocouple) Grounded (Example of Thermocouple) Thermocouple wires are directly welded to the sheath end. As response is faster, it is suitable for measurement under high temperature and high pressure condition. It is not recommended in the presence of hazard and noise voltages because wires are directly welded to the sheath end. Type General type Thermocouple Sheathed type Resistance General type temperature Sheathed type detector Grounded Available Available Not available Not available Completely insulated between the thermocouple element/resistance element and the sheath. The Hot junction is also insulated. Response is slower than the grounded type. Less EMF change by time. Can be used for a comparatively long period of time. Not affected by noise voltage. Exposed (Example of Thermocouple) Thermocouple wires are exposed from the sheath. As response is fastest, it can follow even a little temperature change. Avoid being used over a long period of time under corrosive atmosphere or high temperature and high pressure conditions due to no air tightness and mechanical strength. Ungrounded Exposed Available Available Available Available Available Available Available Not available Tip processing Features Maximum heat resistance degree for welding is 500ºC. Not suitable for food and plating applications since it is largely Silver soldering affected by corrosive. Argon welding Non-MgO sheathed sensors for high temperature use are welded by argon. All of MgO sheathed sensors are welded by argon. Type Lead wire termination Spade lugs for JIS standard "M3" size screw 80 Thermocouple connector Length of Lead Wire (L) Length of Lead Wire (L) Ring lugs for JIS standard "M4" size screw 80 Metal connector Length of Lead Wire (L) Length of Lead Wire (L) No terminal lugs *terminal soldered 80 Length of Lead Wire (L) 8 Thermocouple Connectors If standard connector is used for connecting compensating cables for thermocouple, it will cause indication error because the materials of connection terminals differ from those of leadwires and compensation cables. By using connectors for thermocouple, accuracy of thermocouple can be maintained because connection terminals of the connector are the same materials with thermocouple. There is no concern of intervention of different types of metals. Recommended tightening torque : 1.5kgf•cm Applicable Sheathed diameter : 2.8 to 6mm Standard Size (Polyamide) CSP CSP01- (Jack) (Panel Jack) ø4.7 ø4 + 12.5 30 – 25.4 (Plug) CSP02– + 15 36 12.5 CSP03Panel cutout dimension 13 25.5 CSP03- – CSP02- 25.4 CSP01- 36.7 + CSP03- K 18.6 27.7 Recommended tightening torque : 1.5kgf•cm Applicable Sheathed diameter : 2.8 to 6mm Standard Size : For High temperature (Ceramic) CSC (Plug) (Jack) CSC01- CSC02ø4.7 25.4 K ø4 + 12.5 30 15 37 Recommended tightening torque : 1.5kgf•cm Applicable Sheathed diameter : 0.5 to 4mm CMP02- Miniature Size (Polyamide) CMP 2.3x0.8 (Panel Jack) + 8 21 16.5 (Jack) 3x0.8 K K CMP01- + 26 13 + 3 8 2-ø2.7 Recommended tightening torque : 1.5kgf•cm Applicable Sheathed diameter : 0.5 to 4mm CMR02-K CMR01-K 2.3x0.8 + 8 CMR01-K CMR02-K 21 13 16.5 3x0.8 K K (Jack) 26 K Miniature Size : For High temperature (Ryton) CMR (Plug) 22.5 16.9 22.5 16.5 CMP03- K CMP02- 8 CMP03Panel cutout dimension 8.4 CMP03- CMP01- 12.5 CSC02- CSC01- (Plug) + + 26 • Standard type for high temperature applications (Ryton) : CSR Please contact with our distributors. 8 - K is available. • 3 thermocouple types are available : K, J, and T. (R type is available for polymaide miniature.) • Color of K type connector is yellow, J type is black, and T type is blue. (If ryton is a material for the connector, its color is brown. This is only for K type) Please note that color of each lead wire is different. • The attached rubber packing and metal adaptor Please use rubber seal or metal adapter to stabilize in case the hole size of connector is too bigger against the size of compensation cable or MgO sheathed tube. To stabilize connection, slide rubber seal or metal adapter into the groove of thermocouple connector. Either of seal rubber or metal adapter is standard accessory. 9 Thermocouple Connectors Model Code Material Model and Suffix Code Specifications C Standard Size (Polyamide) Max.120ºC SP Standard Size (Ceramic) Max.900ºC SC Connector *2 Miniature Size (Polyamide) Max.120ºC MP Material Miniature Size (Ryton) *1, *3 Max.220ºC MR Plug 01 Jack 02 Type Panel Jack 03 Plug + Jack 12 13 Plug + Panel Jack K : Yellow K Thermocouple J : Black J Type T : Blue T *1 : For the miniature size (ryton), only K is available. Its color is brown. *2 : For the miniature type (polyamide), R is also available. Its color is green. Please select "R" at thermocouple material code. *3 : Standard type (ryton) K is also available. Please contact with our distributors. Polyamide Ceramic Polyamide Ryton Type Model Code Standard Size (Plug + Jack) CSP12Standard Size (Plug + Panel Jack) CSP13Standard Size (Plug) CSP01Standard Size (Jack) CSP02Standard Size (Panel Jack) CSP03CSC12Standard Size (Plug + Jack) CSC01Standard Size (Plug) Standard Size (Jack) CSC02Miniature Size (Plug + Jack) CMP12Miniature Size (Plug + Panel Jack) CMP13Miniature Size (Plug) CMP01Miniature Size (Jack) CMP02Miniature Size (Panel Jack) CMP03Miniature Size (Plug + Jack) CMR12-K Miniature Size (Plug) CMR01-K Miniature Size (Jack) CMR02-K Lead Clamp CLP-A Lead Clamp Application CLP-B (For miniature size) 1.5 - 3.2 2.8 - 6.5 (For standard size) Model and suffix code for thermocouple connector with lead wire Model Code TE TS1 TS2 TS3 TS4 TSA TSB TM1 TM2 TM3 TM4 TM5 TMA TMB CSP01 + CLP-A + CSP02 CSP01 + CLP-A CSP01 CSP01 + CLP-A + CSP03 CSP01 + CSP02 CSP02 + CLP-A CSP02 CMP01 + CLP-B CMP01 CMP01 + CLP-B + CMP03 CMP01 + CLP-B + CMP02 CMP01 + CMP02 CMP02 + CLP-B CMP02 Type Standard Size (Plug + Clamp + Jack) Standard Size (Plug + Clamp) Standard Size (Plug) Standard Size (Plug + Clamp + Panel Jack) Standard Size (Plug + Jack) Standard Size (Jack + Clamp) Standard Size (Jack) Miniature Size (Plug + Clamp) Miniature Size (Plug) Miniature Size (Plug + Clamp + Panel Jack) Miniature Size (Plug + Clamp + Jack) Miniature Size (Plug + Jack) Miniature Size (Jack + Clamp) Miniature Size (Jack) • For the other types, please contact with our distributors. 10 General purpose type • Sheathed Thermocouples Thermocouple A thermocouple consists of two dissimilar metallic wires, edge of its each wire is jointed, and measures a voltage produced according to a difference of the temperatures through each metallic wire. This effect is called Seebeck effect and has been known from long time ago. If a combination of two dissimilar metallic wires are correct, their thickness or shapes do not effect on temperature measurement. This type of sensor excels in processability for this reason, thus it is widely used in industrial plants. A T2 T1 T1,T2 : Temperature A,B : Metallic wires B Internal structure of Thermocouple Sheathed Thermocouple Insulator(Magnesium oxide) is mounted between the protection tube and the measuring element. This type of sensor features in excellent responsiveness and vibration resistances. General type Protection Tube Thermocouple Element Insulator or glass fiber Spring loaded type Sheathed type Protection Tube Thermocouple Element Magnesium oxide (MgO) Terminal head type (Only for General type) T-30,35(General type) T-30S,35S(Sheathed type) T-100 T-110 Thermocouple connector type K T-70S,75S(Sheathed type) Exposed terminal head type Sleeve type T-80,85(General type) T-80S,85S(Sheathed type) T-101(General type) T-101S(Sheathed type) T-111(General type) T-111S(Sheathed type) Metal connector type T-90(General type) T-90S(Sheathed type) Noble Metal type Protection tube is porcelain No-sleeve type (Only for General type) T-30,35 T-102 T-80 11 (For High Temperature) Lead wire (Compensation lead wire) L2 Red (+) Black (-) K:180 T,J:150 Spring Lead wire (Compensation lead wire) L Lead wire termination Red (+) Black (-) K:180 T,J:150 120° L1 Lead wire termination 10 Spring L1 Silver soldering Protection tube 120° (SUS304) 10 d Thermocouples : T-100/T-110 L Protection tube (SUS304) Silver soldering d T - 100 - d - L1 - L - T - 110 - d - L1 - L2 - L - - - - - Diameter of protection tube - - - Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Length of protection tube Example :T-100-5-100-2000-EXA-Y-K-G-N Diameter of protection tube Thermocouple type Example :T-110-5-100-30-2000-EXA-Y-K-G-N 5.0, 6.0 Length of protection tube Specify length by “mm” (100mm to 1,000mm) Lead wire length Specify length by “mm” (100mm or more) Specify length by “mm” (100mm or more, L1+L2=1,000mm or less) Specify length by “mm” (25mm or more, L1+L2=1,000mm or less) • Length is 25mm without specification. • Please contact distributors regarding other length. • Please contact distributors regarding other length. Lead protection Code EXA EXB Details Fiberglass with stainless steel Fiberglass Operating temperature 0 to 150ºC 0 to 150ºC Lead wire termination Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Thermocouple type Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Measuring junction Mounting bracket Code G NG Code E N *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T Details Grounded Ungrounded Details Compression fitting No bracket • Specify size of mounting braket when code is "E". Class : class 2 Element : Single element * Class 1 is available (Please specify when you order) * Double element is available (Please specify when you order) Maximum temperature for use Thermocouple type Operating temperature for regular use Maximum temperature 300ºC 300ºC 200ºC 400ºC 400ºC 250ºC K J T Specifications • Stainless flexible lead wire is available Model Code : T-100F/T-110F Reference SUS304 Compensation lead wire (Fiberglass) • No waterproof 12 Thermocouples : T-101/T-111 Argon welding D1 120° Serial number Heat shrink label tube L Specification label L1 Lead wire termination Serial number Heat shrink label tube Specification label Red (+) Black (-) L 40 Protection tube (SUS316) Argon welding 120° 40 D1 Red (+) Black (-) L1 Protection tube (SUS304) d Hexagon Sleeve is Lead wire Crimp Sleeve filled with epoxy (Compensation (MAX 120ºC) lead wire) L2 Sleeve is filled with epoxy Lead wire (MAX 120ºC) (Compensation Lead wire termination Sleeve lead wire) Hexagon Crimp (3, 3.2 Grounded Type : Silver soldering) (3, 3.2 Grounded Type : d Silver soldering) T - 101 - d - L1 - L - T - 111 - d - L1 - L2 - L - - - - - Diameter of protection tube - - - Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Lead wire length Sensing junction Lead wire length Sensing junction Mounting bracket Lead protection Mounting bracket Lead protection Length of protection tube Example :T-101-5-100-2000-EXA-Y-K-G-N Diameter of protection tube Thermocouple type Example :T-111-5-100-30-2000-EXA-Y-K-G-N 3.0, 3.2, 4.8, 5.0, 6.0, 6.4, 8.0 Length of protection tube Specify length by “mm” (100mm to 1,000mm) Lead wire length Specify length by “mm” (100mm or more) Specify length by “mm” (100mm or more, L1+L2=1,000mm or less) Specify length by “mm” (25mm or more, L1+L2=1,000mm or less) • Length is 25mm if not specified. • Please contact distributors regarding other length. • Please contact distributors regarding other length. Lead protection Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Lead wire termination Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Thermocouple type Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Operating temperature -20 to +90ºC -55 to +180ºC 0 to 200ºC Details PVC (polyvinyl chloride) Silicone rubber Fluorocarbon polymers (FEP) Code EXD EXE EXF *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Measuring junction Code G NG O Details Grounded Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Exposed * Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket Specify size of mounting braket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) • Please contact distributors regarding other mounting bracket. Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more) (Please specify when you order) Maximum temperature for use Specifications K J T E 3.0 to 3.2 4.8 to 6.4 8.0 3.0 to 3.2 4.8 to 6.4 8.0 4.8 to 6.4 8.0 3.0 to 3.2 4.8 to 6.4 8.0 300ºC 650ºC 750ºC 200ºC 400ºC 450ºC 200ºC 250ºC 200ºC 450ºC 500ºC 400ºC 850ºC 950ºC 300ºC 500ºC 550ºC 250ºC 300ºC 300ºC 500ºC 550ºC • Stainless flexible lead wire is available Model Code : T-101F/T-111F Reference Compensation lead wire (Fiberglass) For flexible lead wire, the dimension of the sleeve is 10 x 40mm.(Lead protection EXB type is same to standard specification.) • No waterproof 13 400ºC 400ºC 400ºC 300ºC 400ºC 400ºC 250ºC 300ºC 300ºC 400ºC 400ºC Diameter of protection tube Lead 3.0 to 5.0 wire type EXA,EXB,EXC EXD,EXF EXE 6.0 to 8.0 8×40 10×40 10×40 5 40 • Spring loaded type is available (Please specify when you order) MAX 120ºC SUS304 300ºC 300ºC 300ºC 200ºC 300ºC 350ºC 200ºC 250ºC 200ºC 300ºC 300ºC Sleeve Dimension (D1) D1 T-101 T-111 Thermocouple Diameter of Operating type protection tube Operating Maximum temperature Maximum temperature for regular use temperature for regular use temperature • Material of protection tube SUS316 is available. (Please specify when you order) Sleeve is Lead wire filled with epoxy Spring (Compensation (MAX 120ºC) (SUS304) lead wire) Sleeve 70 L Dimensions for the spring loaded sleeve is as follows. • Protection tube 8 with extension lead wire EXA, EXB, EXD : 10 x 40mm • Protection tube 3.0 to 8.0 with extension lead wire EXC : 10 x 40mm • Except trom the above: : 8 x 40mm Thermocouples : T-102 Silver soldering (Ungrounded Type : Argon welding) Protection tube (SUS304) 120° Diameter of protection tube (d) : 4.0 or more *1 Lead wire Hexagon Crimp or (Compensation Filled with Epoxy Resin lead wire) Serial number Heat shrink label tube L1 Silver soldering (8 or Ungrounded Type : Argon welding) Lead wire termination d d Diameter of protection tube (d) : 3.0, 3.2 Red (+) Black (-) 120° Protection tube (SUS304) Hexagon Crimp Lead wire termination Serial number Heat shrink label tube L1 L Lead wire (Compensation lead wire) Red (+) Black (-) L *1:Fiber glass lead protection (EXB) : Hexagon Crimp Fluorocarbon polymers lead protection (EXF) : Filled with Epoxy Resin T - 102 - d - L1 - L - T - 102 - d - L1 - L - - - - - - - - - Diameter of protection tube Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Length of protection tube Thermocouple type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Example :T-102-5.0-300-2000-EXA-Y-K-G-N Example :T-102-3.2-300-2000-EXA-Y-K-G-N Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead wire termination Thermocouple type 4.0, 4.8, 5.0, 6.0, 8.0 3.0, 3.2 Specify length by “mm” (30mm to 500mm) • Please contact distributors regarding other length. Specify length by “mm” (100mm to 10,000mm) • Please contact distributors regarding other length. Details Code EXB Fiberglass EXF Fluorocarbon polymers (FEP) Operating temperature 0 to 150ºC 0 to 200ºC Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXE Silicone rubber (Only for 4.8, 5.0, Type K) -20 to +90ºC Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T Measuring junction Code G NG O Details Grounded Ungrounded Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket Specify size of mounting braket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) • Please contact distributors regarding other mounting bracket. * Class 1 is available (Please specify when you order) Class : class 2 Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more) (Please specify when you order) Maximum temperature for use Specifications Thermocouple type K J T Operating temperature for regular use Lead protection (Code) EXA 300ºC 300ºC 200ºC EXB 300ºC 300ºC 200ºC EXE 180ºC 180ºC 180ºC EXF 200ºC 200ºC 200ºC Maximum temperature Lead protection (Code) EXA 400ºC 400ºC 250ºC EXB 400ºC 400ºC 250ºC EXE EXF • Spring loaded type is available (Please specify when you order) Lead wire Spring (Compensation (SUS304) lead wire) 70 Reference L • Material of protection tube SUS316 is available. (Please specify when you order) 14 Thermocouples : T-30/T-35 (3, 3.2 Grounded Type : Silver brazing) Protection tube (SUS304) 120° (10 or more :Hemisphere) Specification label Terminal head Serial number label L1 d d Argon welding 60 120° (10 or more :Hemisphere) PF3/8 Serial number label PF1/2 82 L1 No lead wire T - 30 - d - L1 - - With lead wire T - 30 - d - L1 - L - Protection tube Specification Terminal head (SUS304) label Argon welding No lead wire T - 35 - d - L1 - - With lead wire T - 35 - d - L1 - L - - - - Lead wire termination Thermocouple type Sensing junction Mounting bracket Diameter of protection tube Length of protection tube Lead wire length Lead protection - - - Lead wire termination Thermocouple type Sensing junction Mounting bracket Diameter of protection tube Length of protection tube Lead wire length Lead protection Example :T-30-5-100-K-G-N (No lead wire) :T-30-5-100-2000-EXA-Y-K-G-N (With lead wire) Example :T-30-5-100-K-G-N (No lead wire) :T-30-5-100-2000-EXA-Y-K-G-N (With lead wire) 4.8, 5.0, 6.0, 8.0, 10.0, 12.0, 15.0 Diameter of protection tube 3.0, 3.2, 4.8, 5.0, 6.0, 8.0, 10.0 Length of protection tube Specify length by “mm” (100mm to 1,000mm) Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Lead wire length Lead wire termination Specify length by “mm” (100mm or more) No need to specify in case of without lead wire Lead protection • Please contact distributors regarding 21.7. Thermocouple type Measuring junction Mounting bracket Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw •See Page7 M Metal connector (SCK-1602-P) Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Code G NG O Details Grounded Ungrounded Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Please contact with our distributors. Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Class : class 2 Element : Single element Specify size of mounting bracket when code is "A", "B", or "E". Specify size of flange when code is "C". * Class 1 is available (Please specify when you order) * Double element is available. (Only for T-35) (Please specify when you order) Maximum temperature for use Protection tube : SUS304 Operating Thermocouple Diameter of temperature Maximum type protection tube for regular use temperature Specifications K J T E 3.0 to 3.2 4.8 to 6.0 8.0 or more 3.0 to 3.2 4.8 to 6.0 8.0 or more 3.0 to 6.0 8.0 or more 3.0 to 3.2 4.8 to 6.0 8.0 or more • Material of protection tube SUS316 is available. (Please specify when you order) Reference 15 Operating temperature -20 to +90ºC -55 to +180ºC 300ºC 650ºC 750ºC 200ºC 400ºC 450ºC 200ºC 250ºC 200ºC 450ºC 500ºC 400ºC 850ºC 950ºC 300ºC 500ºC 550ºC 250ºC 300ºC 300ºC 500ºC 550ºC • High temperature type Thermocouple type R, S, B for high temperature type : See page 18. Thermocouples : T-80/T-85 Argon welding Terminal head 17 43 L1 No lead wire T - 80 - d - L1 - - With lead wire T - 80 - d - L1 - L - With lead wire T - 85 - d - L1 - L - - - - Lead wire termination Thermocouple type Sensing junction Mounting bracket 22 - - - Lead wire termination Thermocouple type Sensing junction Mounting bracket Diameter of protection tube Length of protection tube Lead wire length Lead protection Example :T-80-5-100-K-G-N (No lead wire) :T-80-5-100-2000-EXA-Y-K-G-N (With lead wire) Example :T-85-5-100-K-G-N (No lead wire) :T-85-5-100-2000-EXA-Y-K-G-N (With lead wire) 4.8, 5.0, 6.0, 8.0, 10.0, 12.0, 15.0 Diameter of protection tube 3.0, 3.2, 4.8, 5.0, 6.0, 8.0, 10.0 Length of protection tube Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding 21.7. • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) No need to specify in case of without lead wire Lead wire length Lead wire termination 53 No lead wire T - 85 - d - L1 - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead protection Terminal head 120° (10 or more :Hemisphere) 43 L1 Protection tube (SUS304) 70 d 120° (10 or more :Hemisphere) d Protection tube (SUS304) Argon welding Specification label (Reverse side:Serial number label) Specification label (Reverse side:Serial number label) Thermocouple type Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw •See Page7 M Metal connector (SCK-1602-P) Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Operating temperature -20 to +90ºC -55 to +180ºC *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Measuring junction Code G NG O Details Grounded Ungrounded Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Specify size of mounting bracket when code is "A", "B", or "E". Specify size of flange when code is "C". Class : class 2 Class : class 2 * Class 1 is available (Please specify when you order) * Class 1 is available (Please specify when you order) Element : Single element Element : Single element Maximum temperature for use Protection tube : SUS304 Operating Thermocouple Diameter of temperature Maximum type protection tube for regular use temperature Specifications K J T E 3.0 to 3.2 4.8 to 6.0 8.0 or more 3.0 to 3.2 4.8 to 6.0 8.0 or more 3.0 to 6.0 8.0 or more 3.0 to 3.2 4.8 to 6.0 8.0 or more 300ºC 650ºC 750ºC 200ºC 400ºC 450ºC 200ºC 250ºC 200ºC 450ºC 500ºC 400ºC 850ºC 950ºC 300ºC 500ºC 550ºC 250ºC 300ºC 300ºC 500ºC 550ºC Maximum temperature for use Protection tube : SUS304 Operating Thermocouple Diameter of temperature Maximum type protection tube for regular use temperature K J T E 4.8 to 6.0 8.0 or more 4.8 to 6.0 8.0 or more 4.8 to 6.0 8.0 or more 4.8 to 6.0 8.0 or more 650ºC 750ºC 400ºC 450ºC 200ºC 250ºC 450ºC 500ºC 850ºC 950ºC 500ºC 550ºC 250ºC 300ºC 500ºC 550ºC • Material of protection tube SUS316 is available. (Please specify when you order) Reference • High temperature type Thermocouple type R, S, B for high temperature type : See page 19. 16 d Thermocouples : T-90 Argon welding 120° Serial number label Protection tube (SUS304) L1 Adapter (SCK-1602-A) Plug (SCK-1602-P) 43 42 No lead wire T - 90 - d - L1 - - With lead wire T - 90 - d - L1 - L - - - - Lead wire termination Thermocouple type Sensing junction Mounting bracket Diameter of protection tube Length of protection tube Lead wire length Lead protection Example :T-90-5-100-K-G-N (No lead wire) :T-90-5-100-2000-EXA-Y-K-G-N (With lead wire) Lead protection Lead wire termination No need to specify in case of without lead wire Diameter of protection tube Length of protection tube Lead wire length Thermocouple type 3.0, 3.2, 4.8, 5.0, 6.0, 8.0 Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw •See Page7 M Metal connector (SCK-1602-P) Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Measuring junction Code G NG O Details Grounded Ungrounded Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Specify size of mounting bracket when code is "A", "B", or "E". Specify size of flange when code is "C". Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more) (Please specify when you order) Maximum temperature for use Protection tube : SUS304 Operating Thermocouple Diameter of temperature Maximum type protection tube for regular use temperature Specifications 3.0 to 3.2 4.8 to 6.0 8.0 3.0 to 3.2 4.8 to 6.0 8.0 3.0 to 6.0 8.0 3.0 to 3.2 4.8 to 6.0 8.0 K J T E 300ºC 650ºC 750ºC 200ºC 400ºC 450ºC 200ºC 250ºC 200ºC 450ºC 500ºC 400ºC 850ºC 950ºC 300ºC 500ºC 550ºC 250ºC 300ºC 300ºC 500ºC 550ºC Connector Pin No. Double Element Single Element 2 1 Reference SCK-1602- Pin No. Details 1 2 4 3 1 2 SCK-1604- Pin No. Details 1 2 3 4 For connector for T-90, Connector manufactured by Sanwa Connector Laboratory Co., Ltd. is used as standard. Nanaboshi Electric Mfg brand is also available (Please specify when you order). Please specify in case of no need of the plug. 17 Operating temperature -20 to +90ºC -55 to +180ºC Noble Metal Thermocouples : T-30/T-35 (For High Temperature) Terminal head Collar Specification label Protection tube (Porcelain tube PT1, etc) d d Terminal head Protection tube (Porcelain tube PT1, etc) Collar Serial number label Serial number label L2 (30) L2 L1 60 PF3/8 Diameter of protection tube Length of protection tube (L1) Length of protection tube (L2) (50) L1 No lead wire T - 30 - d - L1 - L2 - - With lead wire T - 30 - d - L1 - L2 - L - 82 PF1/2 No lead wire T - 35 - d - L1 - L2 - - With lead wire T - 35 - d - L1 - L2 - L - - - - - Diameter of protection tube Length of protection tube (L1) Length of protection tube (L2) Thermocouple type Sensing junction Mounting bracket Lead wire length Lead protection Lead wire termination Example :T-30-10-200-170-R-NG-N (No lead wire) :T-30-10-200-170-2000-EXA-Y-R-G-N (With lead wire) - - - - Lead wire length Lead protection Lead wire termination 6.0, 8.0, 10.0, 13.0, 15.0, 17.0 Length of protection tube (L1) Specify length by “mm” (130mm to 1,030mm) Specify length by “mm” (150mm to 1,050mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Length of protection tube (L2) Specify length by “mm” (100mm to 1,000mm) Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Lead wire length Specify length by “mm” (100mm or more) Lead wire termination No need to specify in case of without lead wire 6.0, 8.0, 10.0 Thermocouple type Details Code EXA Fiberglass with stainless steel EXB Fiberglass EXD PVC (polyvinyl chloride) Thermocouple type Sensing junction Mounting bracket Example :T-35-10-200-150-R-NG-N (No lead wire) :T-35-10-200-150-2000-EXA-Y-R-G-N (With lead wire) Diameter of protection tube Lead protection Specification label Operating temperature 0 to 150ºC 0 to 150ºC -20 to +90ºC Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) R Ring lugs for JIS standard "M4" size screw Only for Type R N No terminal lugs *terminal soldered •See Page7 M Metal connector (SCK-1602-P) *1 : Other thermocouple connector : See Page 10 Code Code Details Details R Type R (Platinum - Platinum Rhodium13%) B Type B(Platinum - Platinum Rhodium6%) S Type S (Platinum - Platinum Rhodium10%) Measuring junction Code NG Details Ungrounded Mounting bracket Code C N Details Fixed flange No bracket Specify size of flange when code is "C". • Please contact distributors regarding other mounting bracket. Class : class 2 * Class 1 is available. (Thermocouple type : R,S) (Please specify when you order) Element : Single element * Double element is available. (Only for T-35) (Please specify when you order) Maximum temperature for use Thermocouple type Specifications R S B Operating temperature for regular use Maximum temperature 1400ºC 1400ºC 1500ºC 1600ºC 1600ºC 1700ºC *The lists above are operating temperature limits for the element wire. For the protection tube, please refer to page.58 about reference data of protection tube. Reference 18 Noble Metal Thermocouples : T-80/T-85 (For High Temperature) Terminal head Collar Terminal head 70 d Protection tube Collar (Porcelain tube PT1, etc) Specification label (Reverse side:Serial number label) Protection tube (Porcelain tube PT1, etc) 43 d Specification label (Reverse side:Serial number label) (30) L2 L2 L1 43 17 No lead wire T - 80 - d - L1 - L2 - - With lead wire T - 80 - d - L1 - L2 - L Diameter of protection tube Length of protection tube (L1) Length of protection tube (L2) With lead wire T - 85 - d - L1 - L2 - L Thermocouple type Sensing junction Mounting bracket Lead wire length Lead protection Lead wire termination Example :T-80-10-200-170-R-NG-N (No lead wire) :T-80-10-200-170-2000-EXA-Y-R-G-N (With lead wire) 6.0, 8.0, 10.0 Length of protection tube (L2) Lead wire length Lead wire termination Thermocouple type Diameter of protection tube Length of protection tube (L1) Length of protection tube (L2) - - - - Lead wire length Lead protection Lead wire termination Example :T-85-10-200-150-R-NG-N (No lead wire) :T-85-10-200-150-2000-EXA-Y-R-G-N (With lead wire) Specify length by “mm” (130mm to 1,030mm) Specify length by “mm” (150mm to 1,050mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Specify length by “mm” (100mm to 1,000mm) Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Details Code EXA Fiberglass with stainless steel EXB Fiberglass EXD PVC (polyvinyl chloride) Operating temperature 0 to 150ºC 0 to 150ºC -20 to +90ºC Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw •See Page7 M Metal connector (SCK-1602-P) *1 : Other thermocouple connector : See Page 10 Code Code Details Details R Type R (Platinum - Platinum Rhodium13%) B Type B(Platinum - Platinum Rhodium6%) S Type S (Platinum - Platinum Rhodium10%) Code NG Details Ungrounded Mounting bracket Code C N Details Fixed flange No bracket Specify size of flange when code is "C". • Please contact distributors regarding other mounting bracket. Class : class 2 * Class 1 is available. (Thermocouple type : R,S) (Please specify when you order) Element : Single element Maximum temperature for use Thermocouple type R S B Operating temperature for regular use Maximum temperature 1400ºC 1400ºC 1500ºC 1600ºC 1600ºC 1700ºC *The lists above are operating temperature limits for the element wire. For the protection tube, please refer to page.58 about reference data of protection tube. Reference 19 Thermocouple type Sensing junction Mounting bracket 6.0, 8.0, 10.0, 13.0, 15.0, 17.0 Measuring junction Specifications 22 Specify length by “mm” (100mm or more) No need to specify in case of without lead wire Lead protection 53 No lead wire T - 85 - d - L1 - L2 - - - - - - - Diameter of protection tube Length of protection tube (L1) (50) L1 Sheathed Thermocouples : T-101S/T-111S D1 d L1 Filled with Lead wire wire Epoxy Resin (Compensation Lead termination (MAX 120ºC) lead wire) Specification label Serial number label L 40 T - 101S - d - L1 - L - L2 Red (+) Black (-) Heat shrink tube φD1 0.5 to.1.6 (SUS316) :Hemisphere 2.3 to 8.0:120° L1 Protection tube Argon welding 0.5 to.1.6 :Hemisphere 2.3 to 8.0:120° Hexagon Crimp Sleeve Hexagon Crimp Sleeve Filled with Lead wire Lead wire Epoxy Resin (Compensation termination (MAX 120ºC) lead wire) Serial number label Specification label Heat shrink tube L 40 Protection tube (SUS316) Argon welding d - - - - T - 111S - d - L1 - L2 - L Diameter of protection tube - - - - Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Lead wire termination Mounting bracket Length of protection tube Example :T-101S-4.8-100-2000-EXA-Y-K-G-N 0.5 (Only for K,T type), 1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0 Length of protection tube Specify length by “mm” (100mm to 10,000mm) Lead wire length Specify length by “mm” (100mm or more) Specify length by “mm” (100mm or more, L1+L2=10,000mm or less) Specify length by “mm” (25mm or more, L1+L2=10,000mm or less) • Length is 25mm without specification. Lead protection Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Lead wire termination Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Thermocouple type Example :T-111S-4.8-100-30-2000-EXA-Y-K-G-N Diameter of protection tube Thermocouple type Red (+) Black (-) Code EXD EXE EXF Details PVC (polyvinyl chloride) Silicone rubber Fluorocarbon polymers (FEP) Operating temperature -20 to +90ºC -55 to +180ºC 0 to 200ºC *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Measuring junction Code G NG O Details Grounded Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Exposed * Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) * Class 1 is available (Please specify when you order) Class : class 2 Element : Single element * Double element is available. (Diameter of protection tube : 3.2 or more) (Please specify when you order) D1 Specifications Operating temperature Thermocouple Diameter of Operating temperature Sleeve Dimension (D1) protection tube for regular use type for regular use Diameter of 0.5 600ºC protection tube 0.5, 1.0, 1.6, 6.4, 8.0 Lead 1.0 to 2.3 650ºC 2.3, 3.2, 4.8 wire type K 3.2 750ºC EXA,EXB,EXC 800ºC 4.8 to 6.4 8×40 10×40 8.0 900ºC EXD,EXF 1.0 to 2.3 450ºC EXE 10×40 J 3.2 650ºC 4.8 or more 750ºC 0.5 300ºC 1.0 to 2.3 300ºC T 5 3.0 or more 350ºC 1.0 to 2.3 650ºC 40 3.2 E 750ºC 4.8 or more 800ºC • Stainless flexible lead wire is available • Spring loaded type is available • Fluor resin coating is available It is avaiable to cover Fuluorine resin tube with 4.8 (Please specify when you order) Model Code : T-101FS/T-111FS protection tube (SUS316). Total Diameter becomes 6.0. SUS316 Mgo Isolation Fuluorine Silicone resin tube Sleeve rubber (FEP) (SUS304) tube Lead wire Crimp 8 Reference 6 4.8 It is also available to do coating with T-101 whose tube is more than 3.2. These model codes are T-101SC in this case. 3 L1 L 45 Operating temperature for regular use : 180ºC Maximum temperature : 200ºC • Please contact distributors regarding Fuluorine resin tube. MAX 120ºC Sleeve SUS304 Compensation lead wire (Fiberglass) For flexible lead wire, the dimension of the sleeve is 10 x 40mm. When 1.0 to 4.8 of the protection tube with EXB is selected as the extention lead wire, its dimension is 8 x 40mm. • No waterproof Filled with Lead wire Epoxy Resin Spring (Compensation (MAX 120ºC) (SUS304) lead wire) 70 L Dimensions for the spring loaded sleeve is as follows. • Protection tube 1.0 to 4.8 with extension lead wire EXA, EXB, EXC, EXD : 8 x 40mm • Except the above: : 10 x 40mm 20 Sheathed Thermocouples : T-30S/T-35S Protection tube (SUS316) 120° L1 Specification label Terminal head Specification label 120° Serial number label Serial number label PF3/8 60 PF1/2 L1 No lead wire T - 30S - d - L1 - - - 82 No lead wire T - 35S - d - L1 - - - With lead wire T - 30S - d - L1 - L - With lead wire T - 35S - d - L1 - L - - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead wire termination Thermocouple type Sensing junction Mounting bracket Diameter of protection tube Length of protection tube Lead wire length Lead protection - - - Lead wire termination Thermocouple type Sensing junction Mounting bracket Example :T-30S-4.8-100-K-G-N (No lead wire) :T-30S-4.8-100-2000-EXA-Y-K-G-N (With lead wire) Example :T-35S-4.8-100-K-G-N (No lead wire) :T-35S-4.8-100-2000-EXA-Y-K-G-N (With lead wire) Diameter of protection tube 3.2, 4.8, 6.4, 8.0 4.8, 6.4, 8.0 Length of protection tube Specify length by “mm” (100mm to 10,000mm) Specify length by “mm” (100mm to 10,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) Lead protection Lead wire termination No need to specify in case of without lead wire Lead wire length Thermocouple type Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw •See Page7 M Metal connector (SCK-1602-P) Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Operating temperature -20 to +90ºC -55 to +180ºC *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Measuring junction Code G NG O Details Grounded Ungrounded Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element * Double element is available. (Only for T-35S) (Please specify when you order) Operating temperature for regular use Operating temperature Thermocouple Diameter of protection tube for regular use type Specifications K J T E 3.0 to 3.2 4.8 to 6.4 8.0 3.2 4.8 or more 3.2 or more 3.0 to 3.2 4.8 or more 750ºC 800ºC 900ºC 750ºC 800ºC 350ºC 650ºC 750ºC • Fluor resin coating is available Reference 6 4.8 It is avaiable to cover Fuluorine resin tube with 4.8 protection tube (SUS316). Total Diameter becomes 6.0. It is also available to do coating with T-30S/T-35S whose tube is more than 3.2. These model codes are T-30SC/T-35SC in this case. 3 SUS316 Mgo Isolation Fuluorine resin tube (FEP) Example of Model Code T-30SC-6.0-100-PDM-NG-N (No lead wire) L1 • Please contact distributors regarding Fuluorine resin coating Operating temperature for regular use : 180ºC Maximum temperature : 200ºC • Please contact distributors regarding Fuluorine resin tube. 21 Terminal head Protection tube (SUS316) Argon welding d d Argon welding Specify size of mounting braket when code is "A", "B", or "E". Specify size of flange when code is "C". L1 Thermocouple Specification connector (CMP01) label Operating temperature: Argon welding Protection tube Serial Clamp for Max.120ºC number connector (SUS316) label (-) (+) 1.6:Hemisphere 3.2, 4.8:120° K d Thermocouple connector (CMP01) Operating temperature: Argon welding Clamp for Protection tube Serial connector Max.120ºC number (SUS316) label (-) (+) 1.6:Hemisphere 3.2:120° K d Sheathed Thermocouples : T-70S/T-75S L1 34 T - 70S - d - L1 - - - T - 75S - d - L1 - - - Diameter of protection tube Length of protection tube Thermocouple type Diameter of protection tube Length of protection tube Thermocouple type Sensing junction Mounting bracket Example :T-70S-1.6-100-K2-G-N Diameter of protection tube Length of protection tube Thermocouple type Sensing junction Mounting bracket Example : T-75S-3.2-100-K1-G-N 1.6, 3.2, 4.8 1.0, 1.6, 3.2 Specify length by “mm” (100mm to 2000mm) Code Details Code Details Code Details K1 K2 Type K (Chromel-Alumel) class 1 Type K (Chromel-Alumel) class 2 J1 J2 Type J (Iron-Constantan) class 1 Type J (Iron-Constantan) class 2 T1 T2 Type T (Copper-Constantan) class 1 Type T (Copper-Constantan) class 2 Code Measuring junction 45 Details Grounded Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Exposed Please contact with our distributors. G NG O Details Code Mounting bracket Details Code Fixed nipple (nut) Rotary nipple (nut) Fixed flange A B C Compression fitting No bracket E N Specify size of mounting braket when code is "A", "B", or "E". Specify size of flange when code is "C". Class : class 1 or class 2 Element : Single element Operating temperature for regular use Operating temperature Thermocouple Diameter of protection tube for regular use type 1.0, 1.6 3.2 4.8 1.0, 1.6 3.2 4.8 K Specifications J Operating temperature Thermocouple Diameter of type protection tube for regular use 650ºC 750ºC 800ºC 450ºC 650ºC 750ºC Thermocoule connector (jack) 1.0, 1.6 3.2 4.8 T Standard connector: (Material: Ceramic): CSC-01 operating temperature limit 900ºC Thermocoule connector (jack) *Sold separately 25.4 16.5 K – + 8 36 Thermocoule connector (jack) with lead wire Thermocouple connector (CMP02) Lead wire Clamp Reference *Sold separately CSP02- + 26 Regarding thermocouple connectors for high-temperature use, please contact distributors Miniature connector: (Material: Ryton): CMR-01 operating temperature limit 220ºC CMP02- 26 300ºC 350ºC 350ºC (CLP-B) *Sold separately Terminal Treatment 12.5 Thermocoule connector (jack) with lead wire Thermocouple connector (CMP02) Serial number label Lead wire Serial number label *Sold separately Terminal Treatment Clamp L 36 (CLP-A) L Model and suffix code for thermocoule connector (jack) with lead wire Specifications Model and Suffix Code W-BL- Type K (class 2) K2 Type J (class 2) J2 EXA Fiberglass with stainless steel EXB Lead protection Fiberglass EXD PVC (polyvinyl chloride) EXE Silicone rubber Thermocouple Thermocouple connector CMP02 jack (with clamp) TMA connector Thermocouple connector CSP02 jack (with clamp) TSA Spade lugs for JIS standard "M3" size screw Spade lugs for JIS standard "M4" size screw Lead wire Ring lugs for JIS standard "M3" size screw termination Ring lugs for JIS standard "M4" size screw No terminal lugs No terminal lugs *terminal soldered Thermocouple type Y3 Y4 R3 R4 C N Lead wire length Specify length by "mm" (100mm each) (unit: mm) Please contact distributors regarding T type thermocouple. 22 Sheathed Thermocouples : T-80S/T-85S Specification label (Reverse side:Serial number label) Specification label (Reverse side:Serial number label) 120° L1 17 43 L1 With lead wire T - 80S - d - L1 - L - With lead wire T - 85S - d - L1 - L - - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Diameter of protection tube 3.2, 4.8, 6.4, 8.0 Length of protection tube Specify length by “mm” (100mm to 10,000mm) Lead wire length Lead wire termination Thermocouple type Sensing junction Mounting bracket Example :T-85S-4.8-100-K-G-N (No lead wire) :T-85S-4.8-100-2000-EXA-Y-K-G-N (With lead wire) Specify length by “mm” (100mm or more) 4.8, 6.4, 8.0 No need to specify in case of without lead wire • Please contact distributors regarding other length. Thermocouple type Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw •See Page7 M Metal connector (SCK-1602-P) Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Operating temperature -20 to +90ºC -55 to +180ºC *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Measuring junction Code G NG O Details Grounded Ungrounded Exposed * * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket Specify size of mounting braket when code is "A", "B", or "E". Specify size of flange when code is "C". • Please contact distributors regarding other mounting bracket. Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element Operating temperature for regular use Operating temperature for regular use Operating temperature Thermocouple Diameter of protection tube for regular use type K Specifications J T E Reference 23 22 - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead wire termination Thermocouple type Sensing junction Mounting bracket Example :T-80S-4.8-100-K-G-N (No lead wire) :T-80S-4.8-100-2000-EXA-Y-K-G-N (With lead wire) Lead wire termination 53 No lead wire T - 85S - d - L1 - - - No lead wire T - 80S - d - L1 - - - Lead protection 70 120° 43 d Argon welding d Protection tube Terminal (SUS316) head Argon welding Protection tube Terminal (SUS316) head 3.2 4.8 to 6.4 8.0 3.2 4.8 or more 3.2 or more 3.0 to 3.2 4.8 or more 750ºC 800ºC 900ºC 650ºC 750ºC 350ºC 750ºC 800ºC Operating temperature Thermocouple Diameter of protection tube for regular use type K J T E 4.8, 6.4 8.0 4.8 to 8.0 4.8 to 8.0 4.8 to 8.0 800ºC 900ºC 750ºC 350ºC 800ºC Sheathed Thermocouples : T-90S Serial number label d Argon welding Protection tube (SUS316) Adapter (SCK-1602-A) Plug (SCK-1602-P) 1.6:Hemisphere 3.2 to 8.0:120° 43 L1 42 No lead wire T - 90S - d - L1 - - With lead wire T - 90S - d - L1 - L - - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead wire termination Thermocouple type Sensing junction Mounting bracket Example :T-90S-4.8-100-K-G-N (No lead wire) :T-90S-4.8-100-2000-EXA-Y-K-G-N (With lead wire) Lead protection Lead wire termination No need to specify in case of without lead wire Diameter of protection tube Length of protection tube Lead wire length Thermocouple type 1.6, 3.2, 4.8, 6.4, 8.0 Specify length by “mm” (100mm to 10,000mm) Specify length by “mm” (100mm or more) Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Operating temperature -20 to +90ºC -55 to +180ºC *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T E Type E (Chromel-Constantan) Measuring junction Code G NG O Details Grounded Ungrounded type is available depending on specification such as shapes, environment of usage, etc. Exposed * * Exposed-junction Please contact with our distributors. Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Specify size of mounting braket when code is "A", "B", or "E". Specify size of flange when code is "C". * Class 1 is available (Please specify when you order) * Double element is available. (Diameter of protection tube : 3.2 or more) (Please specify when you order) Operating temperature for regular use Class : class 2 Element : Single element Operating temperature Thermocouple Diameter of protection tube for regular use type 1.6 3.2 4.8, 6.4 8.0 1.6 3.2 4.8 or more 1.6 3.2 or more 1.6 3.2 4.8 or more K Specifications J T E 650ºC 750ºC 800ºC 900ºC 450ºC 650ºC 750ºC 300ºC 350ºC 650ºC 750ºC 800ºC Connector Pin No. Double Element Single Element 2 1 Reference SCK-1602- Pin No. Details 1 2 4 3 1 2 SCK-1604- Pin No. Details 1 2 3 4 For connector for T-90S, Connector manufactured by Sanwa Connector Laboratory Co., Ltd. is used as standard. Nanaboshi Electric Mfg brand is also available (Please specify when you order). Please specify in case of no need of the plug. 24 Nicrobell Sheathed Thermocouples Nicrobell Sheathed Thermocouple Wires of traditional metallic sheath (stainless steel, inconel, etc) is likely to receive chemical erosion or metallic fatigue under high temperature circumstance, and these give negative effects on their stability and longevity. Nicrobell Sheath is an epoch making heat resistant alloy and has chemical composition very close to that of the type N (Nicrosil) element, minimizing chemical erosion and metal fatigue. Nicrobell Sheathed N Thermocouple Magnesium Oxide Nicrobell Sheath Nicrobell Sheathed K Thermocouple High Stability Nicrobell sheath has chemical composition very close to that of the type N element and does not generate any metal gas in high temperature range different from conventional alloys such as stainless steel (SUS316, SUS310) and Inconel, thus prevents the element of type N thermocouple from contamination. High Accuracy Our Nicrobell sheath (N) thermocouple is class 1. It is capable of high temperature measurement with high accuracy compared with traditional sheath types. Moreover, its high stability shows the same or higher realization with PL II (platinum II) and R around 1200°C. Because Nicrobell sheath is a nickel based alloy as K type, it minimizes corrosion by metallic gas expansion to its wires under high temperature range, and improves stability, environmental resistance, and thermal resistance of its thermoelectromotive force. Low Cost Nicrobell K thermocouple realizes high stability and environmental resistance with almost same price with traditional Inconel sheath. Progress of basic function results in low cost due to long-term use by stabilizing accuracy of thermoelectromotive force in long-term and by extending periodic replacement by reinforcing K type strength (thermal resistance) in high temperature range. Improved Reliability Traditionally, when talking about environmental resistance for selection of thermocouple metallic sheath, people were likely to more focus on its materials and did not pay much attention on relationship between its materials and wire. Nicrobell sheath is a new created metallic sheath balancing its traditional matter, thus its accountability will be highly progressed Environmental Resistance Nicrobell sheath (N) thermocouple has chemical composition very close to that of the type N element t and does not generate any metal gas in high temperature range different from conventional alloys such as stainless steel (316SS, 310SS) and Inconel, thus prevents the element of type N thermocouple from contamination. Thermocouple Element d D t : More than 10% of D d : More than 18% of D Long Life Nicrobell sheath K type thermocouple can be used for long duration of time in a high temperature range by the difference of performance and traditional thick wire. Long Life Nicrobell sheath (N) thermocouple, which has high stability and environmental resistance, has a longer cycle of periodic replacement and economical for it will less change over the time and has a long life span compared with traditional sheathes. Terminal head type Sleeve type T-101N T-30N T-111N Terminal head type T-35N 25 NICROBELL Sheathed Thermocouples : T-101N/T-111N Filled with Lead wire Lead wire Epoxy Resin (Compensation termination (MAX 120ºC) lead wire) Specification label 40 Hexagon Crimp Sleeve D1 Serial number Heat shrink label tube L L1 Red (+) Black (-) L2 1.0 to.1.6 :Hemisphere 3.2 to 8.0:120° d D1 Protection Argon welding tube (NICROBELL) 1.0 to.1.6 :Hemisphere Hexagon Sleeve 3.2 to 8.0:120° Crimp Filled with Lead wire Epoxy Resin (Compensation (MAX 120ºC) lead wire) Serial number label Specification label Lead wire termination Heat shrink tube Red (+) Black (-) L 40 Protection tube (NICROBELL) Argon welding d T - 101N - d - L1 - L - - - - - T - 111N - d - L1 - L2 - L - Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Lead wire length Sensing junction Lead protection Mounting bracket - - - - Diameter of protection tube Lead wire termination Length of protection tube Example :T-101N-4.8-100-2000-EXA-Y-K-G-N Thermocouple type Lead wire length Sensing junction Lead protection Mounting bracket Example :T-111N-4.8-100-30-2000-EXA-Y-K-G-N Diameter of protection tube 1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0 Length of protection tube Specify length by “mm” (100mm to 10,000mm) Specify length by “mm” (100mm or more, L1+L2=10,000mm or less) Specify length by “mm” (25mm or more, L1+L2=10,000mm or less) • Length is 25mm without specification. Lead wire length Specify length by “mm” (100mm or more) Lead protection Operating temperature Code Operating temperature Details Details Code EXA Fiberglass with stainless steel EXD PVC (polyvinyl chloride) 0 to 150ºC -20 to +90ºC EXB Fiberglass EXE Silicone rubber (Only for Type K) 0 to 150ºC -55 to +180ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC EXF Fluorocarbon polymers (FEP) (Only for Type K) 0 to 200ºC Lead wire termination Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) (Only for Type K) No terminal lugs *terminal soldered N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 *1 : Other thermocouple connector : See Page 10 Thermocouple type Measuring junction Mounting bracket Code Details K Type K (Chromel-Alumel) N Type N (Nicrosil-Nisil) Code G NG Details Grounded Ungrounded Code A B Details Fixed nipple (nut) Rotary nipple (nut) Code E N Details Compression fitting No bracket Specify size of mounting braket when code is "A", "B", or "E". (See Page 6) • Fixed nipple/Rotary nipple is Silver brazing. (Maximum temperature : 500ºC.) • Please contact distributors regarding other mounting bracket. Operating temperature Thermocouple Diameter of protection tube for regular use type Specifications 1.0 1.6, 2.3 3.2, 4.8 6.4 8.0 1.6, 2.3 3.2, 4.8 6.4 8.0 K N 900ºC 1000ºC 1100ºC 1150ºC 1200ºC 1000ºC 1100ºC 1150ºC 1200ºC • Stainless flexible lead wire is available Model Code : T-101FS/T-111FS SUS304 Diameter of protection tube 1.0, 1.6, 2.3 6.4, 8.0 Lead 3.2, 4.8 wire type EXA,EXB,EXC EXD,EXF EXE 8×40 10×40 10×40 5 40 • Spring loaded type is available (Please specify when you order) Filled with Lead wire Epoxy Resin Spring (Compensation Sleeve (MAX 120ºC) (SUS304) lead wire) MAX 120ºC Reference Sleeve Dimension (D1) D1 Class : class 1 Element : Single element Operating temperature for regular use Compensation lead wire (Fiberglass) For flexible lead wire, the dimension of the sleeve is 10 x 40mm. When 1.0 to 4.8 of the protection tube with EXB is selected as the extention lead wire, its dimension is 8 x 40mm. 70 L Dimensions for the spring loaded sleeve is as follows. • Protection tube 1.0 to 4.8 with extension lead wire EXA, EXB, EXC, EXD : 8 x 40mm • Except the above: : 10 x 40mm • No waterproof 26 NICROBELL Sheathed Thermocouples : T-30N/T-35N Terminal head Protection tube (NICROBELL) 120° L1 Specification label 60 PF3/8 PF1/2 L1 82 No lead wire T - 35N - d - L1 - - With lead wire T - 35N - d - L1 - L - - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection 120° Terminal head Protection tube Serial number (NICROBELL) label Specification label Serial number label No lead wire T - 30N - d - L1 - - With lead wire T - 30N - d - L1 - L - Argon welding d d Argon welding Lead wire termination Thermocouple type Sensing junction Mounting bracket Diameter of protection tube Length of protection tube Lead wire length Lead protection Example :T-30N-4.8-100-K-G-N (No lead wire) :T-30N-4.8-100-2000-EXA-Y-K-G-N (With lead wire) - - - Lead wire termination Thermocouple type Sensing junction Mounting bracket Example :T-30N-4.8-100-K-G-N (No lead wire) :T-30N-4.8-100-2000-EXA-Y-K-G-N (With lead wire) 3.2, 4.8, 6.4, 8.0 4.8, 6.4, 8.0 Length of protection tube Specify length by “mm” (100mm to 10,000mm) Specify length by “mm” (100mm to 10,000mm) Lead wire length Specify length by “mm” (100mm or more) Lead protection Operating temperature Code Operating temperature Details Details Code EXA Fiberglass with stainless steel EXD PVC (polyvinyl chloride) 0 to 150ºC -20 to +90ºC EXB Fiberglass EXE Silicone rubber (Only for Type K) 0 to 150ºC -55 to +180ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Lead wire termination No need to specify in case of without lead wire Diameter of protection tube Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw •See Page7 M Metal connector (SCK-1602-P) *1 : Other thermocouple connector : See Page 10 Thermocouple type Measuring junction Mounting bracket Code Details K Type K (Chromel-Alumel) N Type N (Nicrosil-Nisil) Code G NG Details Grounded Ungrounded Code A B Details Fixed nipple (nut) Rotary nipple (nut) Code E N Details Compression fitting No bracket • Fixed nipple/Rotary nipple is Silver soldering. (Maximum temperature : 500ºC.) • Please contact distributors regarding other mounting bracket. Class : class 1 Element : Single element Operating temperature for regular use Specifications Operating temperature Thermocouple Diameter of protection tube for regular use type K N Reference 27 3.2 to 4.8 6.4 8.0 3.2 to 4.8 6.4 8.0 1100ºC 1150ºC 1200ºC 1100ºC 1150ºC 1200ºC Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Temperature sensors for various applications Bayonet Type Bayonet Type The tip is going to be pressure welded to the measured object by mounting bracket. Suitable for measurement of hot runners, dies and moulds. (Variable insertion length type) Thermocouple with bayonet. Length can be easily adjusted. Easy mounting is possible by moving the bayonet cap dependent upon the insertion length. T-221 Spring loaded type T-200 Screwed Tip Type T-210 The tip is M6 size (M8 size is also available) rotary screw. Internal screws will be threaded in the fitting point. *M6, M8 is based on JIS Standard. T-230 Fixing Screw Type for Surface Temperature Fix the sensor at a 4.5 fixed screw hole of the tip with a screw. Suitable for temperature measurement for the tiny spaces. Sleeve type T-201 T-201S (Sheathed type) T-240 T-211 T-211S (Sheathed type) Ring Type for Surface Temperature Suitable for temperature measurement for the pipe shaped objects and the surface of the nozzles. T-250 For Resin Temperature Sheathed Thermocouple for High Temperature (550°C) T-202SH Capable of measurement of the molten resin temperature, such as the inside of the extruder. M16 screw is cut and its tip directly touches to the melting resin. T-260 Withstand pressure : 70MPa (at 250ºC) T-212SH For Resin Temperature Bayonet Type (Variable insertion length type) Thermocouple with bayonet. Length can be easily adjusted. Decide the position of the mounting bracket dependent upon insertion length and fix the spring by fixed screw. By utilizing ZHF (zero-heat-flow) method, it eliminates thermal disturbances and temperature errors between the tip and the outside case and realizes more precise temperature measurement of the melting resin. T-270Z Withstand pressure : 100MPa (at 250ºC) T-220 28 L2 25 17 Silver Silver Spring(SUS304) soldering soldering Protection Lead wire Spring tube Bayonet (SUS304) (Compensation Lead wire (SUS304) termination Sleeve lead wire) 20 2 L 20 50 K:180 T,J:150 L 7 120° L1 L1 K:180 T,J:150 Lead wire Lead wire termination (Compensation lead wire) Spring (SUS304) Bayonet Spring(SUS304) Silver soldering 2 10 7 50 120° Sleeve 10 d Bayonet Type Thermocouples : T-200/T-210 Protection tube (SUS304) Silver soldering d T - 200 - d - L1 - L - T - 210 - d - L1 - L - - - - - - - - - Diameter of protection tube Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Length of protection tube Thermocouple type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Example :T-210-5-100-2000-EXA-Y-K-G-N Example :T-200-5-100-2000-EXA-Y-K-G-N Diameter of protection tube 5.0 Length of protection tube Specify length by “mm” (50mm to 1,000mm) Lead wire length Lead protection Lead wire termination Thermocouple type Specify length by “mm” (50mm to 1,000mm) • Please contact distributors regarding other length. • L2 is 25mm. Other length is available. (Please specify when you order) • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) Details Fiberglass with stainless steel Fiberglass Code EXA EXB Operating temperature 0 to 150ºC 0 to 150ºC Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T Measuring junction Code G NG Details Grounded Ungrounded Mounting bracket Code Details Holder (Specify screw type and length. See Reference.) G No bracket N Class : class 2 Spring press bonding * Class 1 is available (Please specify when you order) Element : Single element * Double element is available (Please specify when you order) Maximum temperature for use Thermocouple type Operating temperature for regular use Maximum temperature 300ºC 300ºC 200ºC 400ºC 400ºC 250ºC K J T 50 Holder • Stainless flexible lead wire is available Model Code : T-200F/T-210F 4 3 For diameter 6 protection tube, thermocouple holder is a special type. Please contact distributors. Bayonet 2 L 3 Screw:R(PT)1/8 L=32,40,62 • Other screw type is available 8.5 9 d 10 14 12.8 29 4 10 (Specify by ordering) SUS304 Pin (3) 12 +0.2 0 7.2 • Diameter 6 protection tube is available. 3.5 Reference Compensation lead wire (Fiberglass) 3 R (PT)1/8 SUS304 • No waterproof 6 * Spring compression : 10 to 20mm • Install bayonet so that its amount of spring compression should be 10mm to 20mm. 12 Specifications Bayonet Type Thermocouples : T-201/T-211 Hexagon 25 Crimp Filled with Sleeve (L2) (SUS304) Epoxy Resin Protection tube (SUS304) Hexagon Argon Crimp Silver welding Filled with Lead wire soldering Bayonet Sleeve Lead wire (SUS304) Epoxy Resin (Compensation Spring termination (MAX 120ºC) lead wire) D1 17 (MAX 120ºC) Specification label 50 Heat shrink tube L 7 Protection tube (SUS304) Argon welding 120° L1 T - 201 - d - L1 - L - Serial number label 40 Bayonet Spring Silver soldering Heat shrink tube L 40 50 L1 Serial number label Specification label Red (+) Black (-) d - - - - T - 211 - d - L1 - L - - - - - Diameter of protection tube Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Length of protection tube Thermocouple type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Example :T-201-5-100-2000-EXA-Y-K-G-G Example :T-211-5-100-2000-EXA-Y-K-G-G Diameter of protection tube 5.0 Length of protection tube Specify length by “mm” (50mm to 1,000mm) Specify length by “mm” (50mm to 1,000mm) • Please contact distributors regarding other length. • L2 is 25mm. Other length is available. (Please specify when you order) • Please contact distributors regarding other length. Lead wire length Specify length by “mm” (100mm or more) Lead protection Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Thermocouple type Measuring junction Mounting bracket Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Code G NG Details Grounded Ungrounded Code G N Details Holder (Specify screw type and length. See Reference.) No bracket Maximum temperature for use Thermocouple type Operating temperature for regular use Maximum temperature 300ºC 300ºC 200ºC 400ºC 400ºC 250ºC K J T Sleeve Dimension (D1) 50 * Spring compression : 10 to 20mm • Install bayonet so that its amount of spring compression should be 10mm to 20mm. 5 40 4 Model Code : T-201F/T-211F 3 +0.2 0 2 7.2 Compensation lead wire (Fiberglass) • No waterproof 3 R (PT)1/8 SUS304 10 • Diameter 6 protection tube is available. L For diameter 6 protection tube, thermocouple holder is a special type. Please contact distributors. 4 Screw:R(PT)1/8 L=32,40,62 • Other screw type is available 8.5 9 d 10 14 12.8 Pin (3) 12 3 (Specify by ordering) SUS304 3.5 Bayonet Lead wire type D1 EXA,EXB,EXC 8 EXD,EXF EXE 10 Holder • Stainless flexible lead wire is available Reference *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T Spring press bonding Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element * Double element is available (Please specify when you order) Specifications Operating temperature -20 to +90ºC -55 to +180ºC 0 to 200ºC Details PVC (polyvinyl chloride) Silicone rubber Fluorocarbon polymers (FEP) 12 Lead wire termination Code EXD EXE EXF D1 2 Red (+) Black (-) 2 D1 7 d 120° Lead wire Lead wire (Compensation termination lead wire) 6 30 Bayonet Type Sheathed Thermocouples : T-201S/T-211S D1 17 Sleeve ④ (SUS304) Silver ⑤ soldering Bayonet Filled with Lead wire (Compensation Lead wire Epoxy Resin Hexagon Spring lead wire) termination Crimp (MAX 120ºC) 50 40 Heat shrink tube T - 201S - d - L1 - L - 50 Bayonet Spring Silver soldering *1 2 *1 5(d=3.2) 7(d=4.8) Heat shrink tube ③L *1 5(d=3.2) 7(d=4.8) Protection tube (SUS316) Argon welding ① d - - - - T - 211S - d - L1 - L - - - - - Diameter of protection tube Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Thermocouple type Length of protection tube Thermocouple type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Example :T-201S-4.8-100-2000-EXA-Y-K-G-G Example :T-211S-4.8-100-2000-EXA-Y-K-G-G ① Diameter of protection tube 3.2, 4.8 ② Length of protection tube Specify length by “mm” (50mm to 1,000mm) Specify length by “mm” (50mm to 1,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. • L2 is 25mm. Other length is available. (Please specify when you order) ③ Lead wire length ④ ⑤ Lead protection Lead wire termination ⑥ Thermocouple type ⑦ Measuring junction ⑧ Mounting bracket Specify length by “mm” (100mm or more) Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE EXF Details PVC (polyvinyl chloride) Silicone rubber Fluorocarbon polymers (FEP) Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Code G NG *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T Details Grounded Ungrounded Code G N Details Holder (Specify screw type and length. See Reference.) No bracket Class : class 2 Spring press bonding * Class 1 is available (Please specify when you order) Element : Single element * Double element is available (Please specify when you order) Maximum temperature for use Specifications Operating temperature -20 to +90ºC -55 to +180ºC 0 to 200ºC Operating temperature for regular use Thermocouple type K J T 400ºC 400ºC 250ºC Sleeve Dimension (D1) Lead wire type D1 EXA,EXB,EXC 8 EXD,EXF EXE 10 * Spring compression : 50 10 to 20mm • Install bayonet so that its amount of spring compression should be 10mm to 20mm. 5 In case of selecting silicon cover (code:EXE), temperature range for usage changes to 180ºC. • Stainless flexible lead wire is available 40 Holder Model Code : T-201FS/T-211FS 4 3 Reference L d 10 4 Diameter of protection tube : 3.2, d=5.2mm Diameter of protection tube : 4.8, d=7.2mm Screw:R(PT)1/8 L=32,40,62 (Specify by ordering) • Other screw type is available 9 8.5 6 3 SUS304 14 12.8 Pin (3) 3.5 12 12 2 10 Bayonet 31 d 0 Compensation lead wire (Fiberglass) SUS304 • No waterproof +0.2 3 R (PT)1/8 D1 ② L1 Serial number label ③L Specification label (+) Black (-) Specification Serial number label label 40 120° 2 Red (+) Black (-) ② L1 120° D1 ① *1 d Argon welding Protection tube (SUS316) Hexagon ④ ⑤ Crimp Sleeve Lead wire Lead wire Filled with (Compensation termination (SUS304) Epoxy Resin lead wire) (MAX 120ºC) Red 25 (L2) Bayonet Type Sheathed Thermocouples : T-202SH/T-212SH (For High Temperature) *2 5 to 25 8 5 to 25 11 *2 2.3 *2 L3 *1 40 L T - 202SH - d - L1 - L - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection S - - L2 Lead wire termination 8 Lead wire termination Thermocouple type Sensing junction S : 25mm L2 : More than 25mm (Specify length by “mm”) 2.3, 4.8 Specify length by “mm” (1000mm to 8000mm) Details Fiberglass with stainless steel Fiberglass Operating temperature 0 to 150ºC 0 to 150ºC Lead wire termination Code Details Y3 Spade lugs for JIS standard "M3" size screw R3 Ring lugs for JIS standard "M3" size screw MS1 Metal connector (SCK-1602-P) MN1 Metal connector (NCS-162-P-CH) MN2 Metal connector (NCS-162-AdF-CH) MN3 Metal connector (NCS-162-PM-CH) Thermocouple type Code K1 K2 Details Type K (Chromel-Alumel) Class 1 Type K (Chromel-Alumel) Class 2 Measuring junction Code G NG Details Grounded Ungrounded T-202SH Code S 91 to Details 90mm More than 90mm (Specify length by “mm”) • L2 should be within L1+L2=500mm. (Maximum) Code TS1 TS2 TS3 TM1 TM2 TM3 N T-212SH Code S 26 to Details Thermocouple connector (CSP01+CLP-A) Thermocouple connector (CSP01) Thermocouple connector (CSP01+CLP-A+CSP03) Thermocouple connector (CMP01+CLP-B) Thermocouple connector (CMP01) Thermocouple connector (CMP01+CLP-B+CMP03) No terminal lugs *terminal soldered Details ! 25mm If temperature of the sleeve may More than 26mm exceed 150ºC, make the L2 longer (Specify length by “mm”) and insulate the sleeve. • L2 should be within L1+L2+80=500mm. (Maximum) Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element Operating temperature for regular use : 550ºC 4 2 5.2 Bayonet L 12 3 3 +0.2 0 *1: Holder L3= holder length (excluding screw) + mounting hole length. More than 60 mm is recommended. R (PT)1/8 *2: Bayonet cap should be fit to the holder in the range of 5 to 25 mm. 6~8mm is recommended as the amount of spring compression. (The gap between the pin holder and the bayonet 10 should be 0 to 2 mm for setting.) 3 Screw:R(PT)1/8 L=32,40,62 (Specify by ordering) 16 Reference S - - L2 Specify length by “mm” (25mm to 500mm) Code EXA EXB Specifications - - Example :T-212SH-4.8-25-EXA-Y3-K2-G-30 Lead protection Length of L2 Protection tube (SUS304) 4.8 Diameter of protection tube Length of protection tube Lead wire length Lead protection Thermocouple type Sensing junction S : 90mm L2 : More than 90mm (Specify length by “mm”) L Hexagon Crimp 120° T - 212SH - d - L1 - L - Example :T-202SH-4.8-25-EXA-Y3-K2-G-S Diameter of protection tube Length of protection tube Lead wire length (50) 40 Bayonet (Stainless Steel) Spring (MAX 550ºC) 80 (50) Sleeve Lead wire Lead wire Spring (Stainless (Compensation termination Steel) (SUS304) lead wire) (MAX 150ºC) 2.3 L1 L1 2.3 *2 5 to 25 L2=90 120° Sleeve Diameter of (Stainless protection tube : 4.8 L2=20 Lead wire Spring (Compensation Lead wire Steel) termination (MAX 150ºC) (SUS304) lead wire) 8 120° Spring (MAX 550ºC) Protection tube (SUS304) 11 4.8 Diameter of protection tube : 4.8 Protection tube (SUS304) Bayonet Spring (Stainless (MAX 550ºC) Steel) Hexagon Crimp(7) L3 *1 L 40 L Bayonet (Stainless Steel) 5 to 25 L2=90 (50) 40 80 Red (+) Black (-) (50) Sleeve Lead wire Spring (Stainless Lead wire termination (SUS304) (Compensation Steel) (MAX 150ºC) lead wire) L2=20 L1 L3 *1 L1 Sleeve (Stainless Lead wire Steel) Spring (Compensation Lead wire termination (MAX 150ºC) (SUS304) lead wire) 8 120° Diameter of protection tube : 2.3 L3 *1 2.3 Diameter of protection tube : 2.3 Protection tube (SUS304) Bayonet Spring (Stainless (MAX 550ºC) Steel) • Other screw type is available 16 32 Silver soldering Protection tube (SUS304) 4.8 Element wire (Fiberglass with stainless steel) Spring (SUS304) Bayonet Spring Lock 120° Lock screw: M4 x 8 25 Lead wire termination Serial number Heat shrink label tube 80 4.8 Bayonet Type Thermocouples : T-220/T-221 Brass (Ni-3 Plating) Element wire (Fiberglass with stainless steel) Bayonet Spring Crimp 15 200 Serial number label L L T - 220 - L - EXA - - T - 221 - L - EXA - - Heat shrink tube Lead wire length Lead wire length Lead protection : EXA, Element wire (Fiberglass with stainless steel) Lead protection : EXA, Element wire (Fiberglass with stainless steel) Lead wire termination Lead wire termination Thermocouple type Thermocouple type Example :T-220-2000-EXA-Y-K Lead wire length Example :T-221-2000-EXA-Y-K Specify length by “mm” (500mm to 10,000mm) Details Code Lead protection Lead wire termination EXA Details Spade lugs for JIS standard "M3" size screw Ring lugs for JIS standard "M4" size screw Metal connector (SCK-1602-P) Thermocouple connector (CSP01+CLP-A+CSP02) No terminal lugs *terminal soldered Code Y R M TE *1 N Details Code Element wire (Fiberglass with stainless steel) (1.0/1X2) EXA Element wire (Fiberglass with stainless steel) (0.65/1X2) Code Y R N Details Spade lugs for JIS standard "M3" size screw Ring lugs for JIS standard "M4" size screw No terminal lugs *terminal soldered • See Page 7. • See Page 7. *1 : Other thermocouple connector : See Page 10 Thermocouple type Code K J T Code K J Details Type K (Chromel-Alumel) Type J (Iron-Constantan) Type T (Copper-Constantan) Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element Details Type K (Chromel-Alumel) Type J (Iron-Constantan) Class : class 2 Element : Single element * Double element is available (Please specify when you order) * Double element is available (Please specify when you order) Measuring junction : Grounded Measuring junction : Grounded * Grounded type is available (Please specify when you order) Maximum temperature for use Maximum temperature 300ºC 300ºC 200ºC 400ºC 400ºC 250ºC K J T Bayonet Maximum temperature for use Operating temperature for regular use Thermocouple type 14 d 10 14 12.8 3.5 300ºC 300ºC 400ºC 400ºC Bayonet SUS303 4 12 Maximum temperature K J SUS304 Pin (3) Operating temperature for regular use 12.6 Thermocouple type 4 12 8.5 8.5 Reference 8 9 Pin (3) 3.5 Specifications 6 5.5 Holder 4 3 Screw:R(PT)1/8 L=32,40,62 2 10 L 3 12 5.2 +0.2 0 3 R (PT)1/8 33 Lead wire termination (Specify by ordering) • Other screw type is available 3 10 4 10 Serial number label 60 5 Heat shrink tube Lead wire (Element wire) Lead wire termination 20 40 Serial number label Heat shrink tube L 20 2 L 4.5 5 Spring (SUS304) Nut : 10 Lead wire termination Lead wire (Element wire) Spring Silver soldering (SUS304) 8 Loose screw M6:P1(SUS304) 4 Screwed Tip Thermocouples : T-230 Fixing Screw Type Thermocouples for Surface Temperature Measurement : T-240 Brass T - 230 - L - - - T - 240 - L - Lead wire length Lead wire length Lead protection Lead protection Lead wire termination Lead wire termination Thermocouple type Thermocouple type Example :T-230-2000-EXA-Y-K Example :T-240-2000-EXA-Y-K Lead wire length Specify length by “mm” (500mm to 10,000mm) Lead protection Code Details EXA Element wire (Fiberglass with stainless steel) (0.3/7X2) EXB Element wire (Fiberglass) (0.3/7X2) EXE Element wire [PVC (polyvinyl chloride) with copper wire braided] (0.1/30X2) * EXE type is Thermocouple K only.(Protection : Black, Flat type) Lead wire termination Thermocouple type - - Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) *1 : Other thermocouple connector : See Page 10 Code Details Type T (Copper-Constantan) T Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element Measuring junction : Grounded Maximum temperature for use Specifications Thermocouple type K J T Operating temperature for regular use Maximum temperature 300ºC 300ºC 200ºC 400ºC 400ºC 250ºC In case of selecting silicon cover (code:EXE), temperature range for usage change to 180ºC. Screw Type Reference Standard M6:P1 M8:P1.25 Optional W1/4 (Please specify when you order) 34 Ring Type Thermocouples for Surface Temperature Measurement : T-250 Silver soldering d Lead wire (Element wire) 40 5 Silver soldering 15° M3×8 L 25 Tube SUS304 Spring SUS304 4 1 Heat shrink tube Serial number label Lead wire termination Hexagon 5 5 5 nut *1 T - 250 - d - L - - - Diameter of ring Lead wire length Lead protection Lead wire termination Thermocouple type Example :T-250-50-2000-EXA-Y-K Diameter of Specify length by “mm” (25mm to 150mm) (Standard : 30, 35, 40, 45, 50, 55, 60, 65) ring Lead wire length Specify length by “mm” (500mm to 10,000mm) Lead protection Lead wire termination Thermocouple type Code EXA EXB Details Element wire (Fiberglass with stainless steel) (0.3/7X2) Element wire (Fiberglass) (0.3/7X2) Code Details Code Details Y Spade lugs for JIS standard "M3" size screw TE *1 Thermocouple connector (CSP01+CLP-A+CSP02) N No terminal lugs *terminal soldered R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) •See Page7 Code Details K Type K (Chromel-Alumel) J Type J (Iron-Constantan) Code Details Type T (Copper-Constantan) T Class : class 2 * Class 1 is available (Please specify when you order) Element : Single element Measuring junction : Grounded Maximum temperature for use Specifications Thermocouple type K J T Reference 35 Operating temperature for regular use Maximum temperature 300ºC 300ºC 200ºC 400ºC 400ºC 250ºC *1 : Ring width 7mm or 10mm are also available Width of Ring Lock screw size *1 5mm M3X8 Standard 7mm M4X8 Optional 10mm M4X8 *1 : Other thermocouple connector : See Page 10 Thermocouples for Resin Temperature : T-260/T-270Z 70 20±0.5 Lead wire (Compensation lead wire) 30 15 5 M16 P:1.5 Silver soldering 23×26 SUS304 Thermocouple connector (SUS304) (CSP01) 90° 8 5 13 19 115 Thermocouple connector (CSP02) 4.8 ±0.05 5 8 5 6±0.5 SUS316 MgO insulation Silicon resin 14 ±0.07 10 ±0.07 M16 P:1.5 Silicon resin 26×30 Silver soldering Thermocouple connector (SUS304) SUS304 (CSP01) 90° 14 ±0.07 10 ±0.07 5 ±0.05 Silver soldering 59 30 6±0.5 Thermocouple connector (CSP02) Lead wire termination 20±0.5 Lead wire (Compensation lead wire) 30 15 Lead wire termination L 36.4 L 36.4 T - 260 - L - - - Lead wire length Lead protection Lead wire termination Thermocouple type T - 270Z - L Lead wire length Lead protection Example :T-260-2000-EXA-Y-K2 Lead wire length Lead protection Lead wire termination Thermocouple type Specifications 13 115 - Lead wire termination Thermocouple type Example :T-270Z-2000-EXA-Y-K2 Specify length by “mm” Code EXA EXB EXE Details Element wire (Fiberglass with stainless steel) Element wire (Fiberglass) Element wire [PVC (polyvinyl chloride) with copper wire braided] (Only for Type K) Code Details Code Details No terminal lugs *terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1602-P) Code Details K2 Type K (Chromel-Alumel) J2 Type J (Iron-Constantan) Class : class 2 Measuring junction : Grounded (T-260 is available for ungrounded type. Please specify when you order) Maximum temperature for use : 400ºC Material of protection tube : SUS304(T-260), SUS316(T-270Z) Material body : SUS304 withstand pressure : 70MPa (T-260, at 250ºC), 100MPa (T-270Z, at 250ºC) Select codes from the below when order lead wires only. Mounting hole (Unit:mm) Model and Suffix Code W-BL- Thermocouple type Type K (class 2) K2 J2 Type J (class 2) Fiberglass with stainless steel EXA Fiberglass EXB Lead protection PVC (polyvinyl chloride) EXD EXE Silicone rubber Thermocouple Thermocouple connector CSP02 jack (with clamp) TSA connector Spade lugs for JIS standard "M3" size screw Spade lugs for JIS standard "M4" size screw Lead wire Ring lugs for JIS standard "M3" size screw termination Ring lugs for JIS standard "M4" size screw No terminal lugs No terminal lugs *terminal soldered Lead wire length Specify length by "mm" (100mm each) (unit: mm) ±0.1 20 90° 16 Specifications 30 10.3 +0.1 +0.2 626 M16P1.5 Reference Y3 Y4 R3 R4 C N Thermocouple for Resin Temperature Accurate measurement of resin temperature was difficult in general as there are many thermal disturbances as well as high temperature and high pressure. T-260/T-270Z has an excellent resistance against high temperature and high pressure. Moreover, T-270Z can measure resin temperature change even there are thermal disturbances because of its Zero-Heat-Flow structure. That leads to be stable resin temperature control. Because the barrel temperature will be transferred to the protection tube, traditional sensors negatively effects on their measurements. T-270Z realizes its accurate measurement of the resin temperature by compensating the barrel temperature. Condition where resin temperature is higher than barrel temperature Conventional sensor T-270Z Resin temperature Temperature Barrel Tempearture Temperature Resin temperature Resin temperature Measuring temperature Measuring temperature Barrel temperature Barrel temperature Extruder Time Time When the resin temperature is lower than the barrel temperature, traditional sensors detects a slightly higher degree than the actual resin temperature. 36 Adhesive and exposed tip type temperature sensor ST-50/51 Adhesive type temperature sensor : Max. 300°C Glass cloth base type ST-50 Sensing point (Adhesive point) ST-51 Polyimide sheet type Sensing point (Adhesive point) Polyimide sheet type (Fine type) ST-51S Sensing point (Adhesive point) Exposed tip type temperature sensor : Max. 300°C Glass cloth base type ST-50B Sensing point RK C ST -50 ST-51B Polyimide sheet type Sensing point Polyimide sheet type Glass cloth base type ST-50 ST-50B ST-51 ST-51S ST-51B Glass cloth base Glass cloth base 6.7mm Polyimide sheet 6.7mm Thickness : 0.34mm Thickness : 0.34mm Thickness : 0.15mm Thermocouple K element wire 107mm type : 50µm or 100µm 307mm, 507mm type : 100µm Sensing point Adhesive pasting part Thermocouple K element wire 100mm type : 50µm or 100µm 300mm, 500mm type : 100µm Sensing point Exposed part 4mm 7mm 6.7mm 6.7mm Thickness : 0.13mm Thermocouple K element wire 107mm type : 50µm Sensing point Adhesive pasting part Sensing point 7mm 2.3mm Thickness : 0.15mm Thermocouple K element wire 107mm type : 50µm Adhesive pasting part 7mm Sensing point Thermocouple K element wire 107mm type : 50µm Exposed part 4mm 4mm Fast response Durable adhesive tape As the heat capacity of the sensor is very small temperature can be measured instantly. The adhesive tape can be repeatedly applied to and detached from various types of surfaces. <Durability of adhesive tape> • Up to 150°C (302°F) : Repeated use and detachment is available. • Up to 200°C (393°F) When temperature stays above 150°C (302°F), repeated use and detachment is available. • Up to 250°C (482°F) When temperature stays above 200°C (392°F), repeated use and detachment is available. • Higher than 250°C (482°F) Adhesive part will be burnt. Repeated use is not available. 250°C 0.1sec 0°C < ST-50 > Measuring up to 300°C (572°F) Up to 300°C(572°F) can be measured by the tip with an adhesive tape. 37 Polyimide sheet Polyimide sheet External Dimensions 4 ST-50/ST-51 Adhesive pasting part Thermocouple K element wire ST-50 : 50μm or 100μm ST-51 : 100μm ST-50B/51B Connector terminal Thermocouple K element wire ST-50 : 50μm or 100μm ST-51 : 100μm Thickness : ST-50 : 0.34mm ST-51 : 0.15mm 4 ST-50-300: 307mm, ST-50-500: 507mm Thermocouple K Adhesive element wire pasting part Thickness : 0.34mm ST-50B-300 ST-50B-500 Connector terminal Thickness : ST-50 : 0.34mm ST-51 : 0.15mm ST-50B-300: 300mm, ST-50B-500: 500mm 6.7 6.7 ST-50-300 ST-50-500 100 6.7 6.7 107 Thermocouple K element wire 100μm Connector terminal 100μm Connector terminal Thickness : 0.34mm 2.3 107 40 6.7 7 ST-51S Adhesive Thermocouple K pasting part element wire Thickness : 0.13mm Thickness : 0.18mm Connector terminal 50μm Specifications <ST-50/ST-51/ST-51S> ST-50/50B : Glass cloth base sheet ST-51/51S/51B : Polyimide sheet -40 to 300°C (-40 to 577°F) Operating Temperature ST-51S : ST-50/50B/51S/51B : 0 to 300°C (32 to 577°F) Type K Thermocouple ST-50/50B : 100/300/500mm Type Sensor Length ST-51/51S/51B : 100mm Type ST-50/50B : 0.34mm Sensor Thickness ST-51/51S/51B : 0.13mm 50μm/100μm (100mm Type) Element wire diameter ST-50/50B : 100μm (300/500mm Type) ST-51/51S/51B : 50μm Sheet Material ST-51S (50μm element wire) ST-50/51 51Ω ±1.3°C 0.03sec 51Ω ±1.3°C (100μm element wire) 0.08sec 17Ω ±1.5°C ST-50-300 (100μm element wire) 0.08sec 41Ω ±1.5°C ST-50-500 (100μm element wire) 0.08sec 66Ω ±1.5°C ST-50B-100-D 0.03sec 17Ω ±1.5°C ST-50B-300 (100μm element wire) 0.03sec 41Ω ±1.5°C ST-50B-500 0.03sec 66Ω ±1.5°C ST-50B/51B (50μm element wire) ST-50-100-D PPS resin 230°C ø3.3 Extended cable, Standard 1m Silicon rubber coated (Green) 7.0Ω or less (1m) 180°C Approx 20g A (Cable 1m, Y-sharped terminal lug type) (Ca (100μm element wire) (100μm element wire) *1 : Response when temperature of paraffin is 250°C (482°F). *2 : Accuracy when temperature on metal surface is 100°C (212°F). 35 Cable length : 1m (Standard) Open the slide cover. Max. 230°C Cable Insert the non-adhesive edge of the sensor. Max. 180°C 7.5 Connector 10.6 How to connect ST-50/ST-51 sensor Slide cover type connector ø3.3 10.4 12.7 Cable Max. temperature Weight 0.08sec (50μm element wire) <W-ST50A> Connector Cable for ST-50/ST-51 Connector material Connector Max. temperature Cable Cable material Resistance value *2 Response of *1 Resistance value Accuracy 95.0% (With cable 1m) Response of Metal Surface (Adhesive type) ±1.2°C 51Ω 0.08sec 50μm element wire type : 0.4sec 100μm element wire type : 0.9sec Terminal Connector for DP-700 Solder treatment type W-ST50A-1000-N W-ST50A-1000-6C DP-700 Connector Cable for ST-50/ST-51 Non-treatment type Close the slide cover. W-ST50A-1000-C Connector for DP-350/500 W-ST50A-1000-3C Y-sharped lug type Miniature-thermocouple connector plug (CMP-01) type W-ST50A-1000-TM1 W-ST50A-1000-Y3 Model and Suffix Code <ST-50> Glass cloth base type ST-50 (Adhesive type) Contents Model Code Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set ST-50 ST-50-100-D Length : 107mm, Element Wire Diameter 100μm, 5 pieces per set Length : 307mm, Element Wire Diameter 100μm, 1 piece ST-50-300 Length : 507mm, Element Wire Diameter 100μm, 1 piece ST-50-500 <ST-51> Polyimide sheet type ST-50B (Exposed tip type) Model Code ST-50B-100-04 ST-50B-100-04-D ST-50B-300-04 ST-50B-500-04 Contents Length : 104mm, Element Wire Diameter 50μm, 5 pieces per set Length : 104mm, Element Wire Diameter 100μm, 5 pieces per set Length : 304mm, Element Wire Diameter 100μm, 1 piece Length : 504mm, Element Wire Diameter 100μm, 1 piece ST-50B (Exposed tip type) ST-51 (Adhesive type) Model Code ST-51-100-C DP-350 Contents Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set Contents Model Code ST-51B-100-C Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set <ST-51S> Polyimide sheet type <ST-50 Connector> ST-51S (Adhesive type) Model Code W-ST50A-1000-3C W-ST50A-1000-6C W-ST50A-1000-Y3 W-ST50A-1000-N W-ST50A-1000-C Contents Model Code ST-51S-100-C Length : 107mm, Element Wire Diameter 50μm, 5 pieces per set Contents ST-50/51 Connector cable for DP-350/500 connection (1m) ST-50/51 Connector cable for DP-700 connection (1m) Y-sharped terminal lug type ST-50/51 Connector cable (1m) Solder treatment type ST-50/51 Connector cable (1m) Non-treatment type ST-50/51 Connector cable (1m) connector plug (CMP-01) type W-ST50A-1000-TM1 Miniature-thermocouple ST-50/51 Connector cable 38 Temperature Sensors for Extremely Small Surface ST-55/56 Features Measuring point on the tip Measuring temperature in a small surface area Fluorine resin coating type (With adhesive tape) A fine thermocouple enables measurement of a fine surface or a surface with small thermal capacity such as SMT parts. Measuring point Measuring up to 500 °C (932°F) (Ceramic coating type) Adhesive tape Ceramic coating type can measure up to 500°C (932°F) and fluorine resin coating type up to 260°C (500°F). Optional adhesive tape on the tip Up to 260°C (500°F) (Fluorine resin coating type) Optional adhesive tape on the fluorine resin coating type allows the tip to stick to an exact spot for measurement. Ceramic coating type Measuring point Fast response with fine thermocouple As the heat capacity of the sensor is very small temperature can be measured instantly. Response of Metal Surface ST-56 (Fluorine resin coating type) 150 ST-56 (Ceramic coating type) 150 0.076 0.127 0.25 100 Up to 500°C (932°F) 0.1 0.2 0.32 100 1sec 1sec 50 50 0 0 ST-55 Measuring point ST-55 has a joint which enables a longer length Tip Side Thermocouple (Fluorine resin coating) Joint Extended Thermocouple Terminal Fluorine resin coating type Measuring point Tip Side Thermocouple (Ceramic coating) Joint Extended Thermocouple Terminal Ceramic coating type ST-56 Measuring point ST-56 is a seamless thermocouple Tip Side Thermocouple (Fluorine resin coating) Fluorine resin coating type Measuring point Tip Side Thermocouple (Ceramic coating) Ceramic coating type 39 Terminal Terminal Temperature Sensors for Extremely Small Surface ST-55 Ceramic coating type : ST-55K-C Fluorine resin coating type : ST-55K-T Extended Thermocouple Lead wire Joint Fluorine resin coating termination Silicone rubber coating Tip Fluorine resin coating Measuring point +2% +20 L1 0 (1000mm or less : L1 0 ) 30 3 L2 L3 ST - 55K - L1 +2% 0 (1000mm -G- L2 - Thermocouple type or less : L2 +2% ST - 55K - - L3 Shape of Thermocouple (Element wire diameter/Coating) Length of thermocouple element wire Adhesive tape for tip Joint specifications Shape of extended thermocouple (Element wire diameter/Coating) Length of extended thermocouple element wire Lead wire termination 0.6 0.3 0.4 L2 - Shape of Extended Thermocouple (Element wire diameter/Coating) Length of extended thermocouple element wire Lead wire termination Joint specifications Example :ST-55K-CA0300N-G-TD1000-Y Code Details CA ø0.1 Ceramic coating (Single thermocouple type) CB ø0.2 Ceramic coating (Single thermocouple type) 0.7 0.5 ø0.076 ø0.076 ø0.127 Code : TA Code : TB Code : TC ø0.1 x 2 ø0.2 x 2 Code : CA Code : CB Specify every 50mm unit Code P G N Details Polymide tape Glass cloth base tape None N: None Silicone rubber coating (Max. temperature : 170°C) Details Code TC ø0.127 Fluorine resin coating (Paired thermocouple type) TD ø0.254 Fluorine resin coating (Paired thermocouple type) 0.7 0.5 ø0.127 Fluorine resin coating Paired thermocouple type 1.0 0.6 Code : TC ø0.254 Fluorine resin coating Paired thermocouple type Code : TD Unit : mm (Min.200mm) Specify every 50mm unit • Please select length so that a total resistance of thermocouple become 100Ω or less. Details CMP01-K (RKC product) Material : Polyamide (Max. temperature : 140°C (284°F)) CMR01-K (RKC product) Material : PPS resin (Max. temperature : 220°C (428°F)) 1260-K (MARINE product) (Max. temperature : 205°C (401°F)) Spade lugs for JIS standard "M3" size screw *1 Conforming to cable connector for DP-350/700 connection No terminal lugs *terminal soldered Code C1 C2 C3 Y G N *1 Spade lugs for JIS standard “M3” size screw is not available if extended thermocouple was specified ø0.127 (Code : TC). Thermocouple connector (Code:C3) L2 45 16.5 8 Code No symbol 03 to 30 31.7 16 7.9 Conforming to cable connector for DP-350/700 connection (Code:G) L2 50 6.7 Spade lugs for JIS standard "M3" size screw (Code : Y) L2 20 40 No terminal lugs (Code : N) L2 20 15 15 Details Length of exposed tip : 2mm (Standard) Length of exposed tip : 3 to 30mm (Specify every 1mm unit) Class : Accuracy : Specifications +20 or less : L2 0 ) Type K L2 (Only for ST-55K-T ) L1 N - G - Adhesive tape for tip Code Details TA ø0.076 Fluorine resin coating (Single thermocouple type) TB ø0.076 Fluorine resin coating (Paired thermocouple type) TC ø0.127 Fluorine resin coating (Paired thermocouple type) Thermocouple connector (Code:C1,C2) Length of exposed tip 20 40 +2% 0 (1000mm Shape of Thermocouple (Element wire diameter/Coating) Length of thermocouple element wire Example :ST-55K-TA0300P-G-TD1000-Y-05 Thermocouple type 3 Thermocouple type Length of exposed tip Joint specifications 30 L2 Lead wire termination Adhesive tape for tip +20 ) Shape of extended thermocouple (Element wire diameter/Coating) Length of extended thermocouple element wire Shape of Thermocouple (Element wire diameter/Coating) Length of thermocouple element wire Extended Thermocouple Fluorine resin coating Joint Lead wire Silicone rubber termination coating Tip Ceramic coating L1 0 (1000mm or less : L1 0 ) 20 40 +20 0 Measuring point Equal to JIS class 2 (Only for fluorine resin coating type) ±0.5%±1°C • Accuracy when temperature 100°C on metal surface (copper) is measured. (Prior to to factory) Response time : ø0.076 Fluorine resin coating 0.2 sec (Response of 63.2%) 0.8 sec (Response of 95.0%) ø0.1 x 2 Ceramic coating 0.2 sec (Response of 63.2%) 0.5 sec (Response of 95.0%) • Accuracy when temperature on metal surface is measured. Maximum operating temperature 1) Measuring point : Fluorine resin coating : 300°C (Coating section 260°C) Ceramic coating : 500°C 2) Adhesive tape : 300°C 3) Joint section : 170°C 4) Extended section : 260°C Thermocouple resistance per 100mm ø0.076mm : 20Ω, ø0.127mm : 8Ω, ø0.254mm : 2Ω, ø0.10mm : 12Ω, ø0.20mm : 3Ω, ø0.32mm : 1.2Ω Adhesive tape for tip (For fluorine resin coating type) Mount Reference 40 25 5 20 10 Polymide adhesive tape or Glass cloth base adhesive tape The adhesive tape permits the tip to stick to various types of surfaces. Repeated peeling and sticking is possible. <Durability of adhesive tape> • Up to 150°C (302°F) : Repeated use. • Up to 200°C (392°F) : Repeated use, as long as temperature stays above 150°C (302°F). • Up to 250°C (482°F) : Repeated use, as long as temperature stays above 200°C (392°F). • More than 250°C (482°F) : Adhesive will burn and no longer be used. However, the number of sticking times differs depending on the environment where the adhesive is used. 40 Temperature Sensors for Extremely Small Surface ST-56 Ceramic coating type : ST-56K-C Fluorine resin coating type : ST-56K-T Measuring point Lead wire termination Thermocouple (Fluorine resin coating) Measuring point Lead wire termination Thermocouple (Ceramic coating) 20 40 L2 20 40 L1 ST - 56K - L1 L - ST - 56K - -L2 Thermocouple type Adhesive tape for tip Shape of Thermocouple (Element wire diameter/Coating) Lead wire termination Length of exposed tip Length of thermocouple element wire Shape of Thermocouple (Element wire diameter/Coating) Length of thermocouple element wire Adhesive tape for tip Lead wire termination Details ø0.076 Fluorine resin coating (Single thermocouple type) ø0.076 Fluorine resin coating (Paired thermocouple type) ø0.127 Fluorine resin coating (Paired thermocouple type) ø0.254 Fluorine resin coating (Paired thermocouple type) 0.7 0.6 0.3 Length of exposed tip 0.4 Code Details CA ø0.1 Ceramic coating (Single thermocouple type) CB ø0.2 Ceramic coating (Single thermocouple type) CC ø0.32 Ceramic coating (Single thermocouple type) 1.0 0.6 0.5 ø0.076 ø0.076 ø0.127 ø0.254 ø0.1 x 2 ø0.2 x 2 ø0.32 x 2 Code : TA Code : TB Code : TC Code : TD Code : CA Code : CB Code : CC Specify every 200mm unit • Please select length so that a resistance of thermocouple become 100Ω or less. Code P G N Details Polymide tape Glass cloth base tape None Code C1 C2 C3 Y G N Details CMP01-K (RKC product) Material : Polyamide (Max. temperature : 140°C (284°F)) CMR01-K (RKC product) Material : PPS resin (Max. temperature : 220°C (428°F)) 1260-K (MARINE product) (Max. temperature : 205°C (401°F)) Spade lugs for JIS standard "M3" size screw *1 Conforming to cable connector for DP-350/700 connection No terminal lugs *terminal soldered N: None *1 Spade lugs for JIS standard “M3” size screw is not available if extended thermocouple was specified ø0.076, ø0.127,ø0.10 (Code : TA/TB/TC/CA). Thermocouple connector (Code:C1,C2) Thermocouple connector (Code:C3) L2 45 8 Code No symbol 03 to 30 31.7 16 7.9 Conforming to cable connector for DP-350/700 connection (Code:G) L2 50 6.7 Spade lugs for JIS standard "M3" size screw (Code : Y) L2 20 40 No terminal lugs (Code : N) L2 Equal to JIS class 2 (Only for fluorine resin coating type) ±0.5%±1°C • Accuracy when temperature 100°C on metal surface (copper) is measured. (Prior to to factory) Response time : ø0.076 Fluorine resin coating 0.2 sec (Response of 63.2%) 0.8 sec (Response of 95.0%) ø0.1 x 2 Ceramic coating 0.2 sec (Response of 63.2%) 0.5 sec (Response of 95.0%) • Accuracy when temperature on metal surface is measured. Maximum operating temperature 1) Measuring point : Fluorine resin coating : 300°C (Coating section 260°C) Ceramic coating : 500°C 2) Adhesive tape : 300°C 3) Joint section : 170°C 4) Extended section : 260°C Thermocouple resistance per 100mm ø0.076mm : 20Ω, ø0.127mm : 8Ω, ø0.254mm : 2Ω, ø0.10mm : 12Ω, ø0.20mm : 3Ω, ø0.32mm : 1.2Ω Adhesive tape for tip (For fluorine resin coating type) Mount Reference 40 25 5 20 10 Polymide adhesive tape or Glass cloth base adhesive tape 41 20 15 15 Details Length of exposed tip : 2mm (Standard) Length of exposed tip : 3 to 30mm (Specify every 1mm unit) Class : Accuracy : Specifications Shape of Thermocouple (Element wire diameter/Coating) Example : ST-56K-CA0500N-Y 16.5 (Only for ST-56K-T ) Adhesive tape for tip Lead wire termination Type K Code TA TB TC TD L2 Length of exposed tip Thermocouple type Length of thermocouple element wire Example : ST-56K-TA0500P-Y-05 Thermocouple type L N- The adhesive tape permits the tip to stick to various types of surfaces. Repeated peeling and sticking is possible. <Durability of adhesive tape> • Up to 150°C (302°F) : Repeated use. • Up to 200°C (392°F) : Repeated use, as long as temperature stays above 150°C (302°F). • Up to 250°C (482°F) : Repeated use, as long as temperature stays above 200°C (392°F). • More than 250°C (482°F) : Adhesive will burn and no longer be used. However, the number of sticking times differs depending on the environment where the adhesive is used. Thermocouple Type Non Contact Temperature Sensors : ST-100 Features When contact thermocouple was used for measuring a surface temperature of moving objects such as roller and rotationary objects, it causes tremendous consumption to the sensor or damages to the surface of the measured object, this caused error in measurement due to friction heat. This problem can be solved by putting a distance between a sensor and a measured object, however, there still causes influence of disturbance by thermal connection failure, slower response of temperature for measuring object, poor linearlization or slower response ST-100 uses uniquely designed triple measuring elements (thermocouples). Change of connection method and use of movable structure have solved these problems. Moreover, it can be used with connecting indicator and controller for K type thermocouple since output characteristics is similar to traditional contact-type thermocouple Specifications Application : Roller and Moving objects (Sheets) Measuring method : Non-contact Measuring element : Thermocouple K (Daiameter of element : 0.08) Measuring range : Ambient temperature to 300°C Response time : Approx.30 sec (Response of 98%) Approx. 6 sec (Response of 63%) * At metal surface measuring Measuring accuracy : Within ±3°C (at 200°C) * When output is adjusted at the middle of the measuring range. Measuring distance : Distance between sensor surface of ST-100 and measured object should be kept 0.5 to 1.5mm Keep a cetrain distance when measuring. (1mm when it is with distancer) Output signal : Thermocouple K output Lead wire : 6 Silicone rubber protection lead (KX type, 3m) Output impedance : 50Ω Example of Application ST-100 Model Code Example of non-contact temperature measurement for rotating heat roller Model and Suffix Code Specifications Thermocouple type Lead wire length (unit: mm) Lead wire termination Lead protection Distancer (Roller) ST-100 K Type K 1000 to 20000mm (Standard :3000mm) K / * *1000 to 5000mm (Specify 500mm each) 6000 to 20000mm (Specify 1000mm each) Spade lugs for JIS standard "M3" size screw Spade lugs for JIS standard "M4" size screw No terminal lugs No terminal lugs *terminal soldered Silicone rubber (Blue) None With distancer (Roller) Y3 Y4 C N D No symbol D External Dimension Unit : mm With distancer (Roller) Output adjustment screw 6 48 33 6 Output adjustment screw 20 6 11 29 70 6 2-8 25 30 24 28 Measuring point 1 25 to 32 57 56 0.5 to 1.5 28 to 32 56 30 11 Lead wuire 11 48 Lead wuire Measuring point 2-8 8 25 20 27 48 31 65 28 23 68 Fluorocarbon polymers roller 42 Thermocouple Type Non-Contact Temperature Sensors : ST-100K Features ST-100K, a compacted type of ST-100, is a non-contact thermocouple sensor for surface measurement of moving objects such as roller, rotating objects, and sheet. Specifications Application : Insulator surface (Roller and Moving objects (Sheets)) Measuring method : Non-contact Measuring element : Thermocouple K, Class 2 (Daiameter of element : 0.076) Measuring range : Ambient temperature to 260°C (Maximum continuous operating temperature : 200°C) Measuring accuracy : Within ±2°C (Ambient temperature to 150°C) Within ±5°C (150 to 260°C) * Measuring distance : 0.5mm If a measuring distance will become within 0.5mm, indicated value is higher than actual temperature. Measuring distance : 0.5mm (Fixed) Spring stroke : 0.5 to 2mm (ST-100K) 0.2 to 1mm (ST-100K1) Output signal : Thermocouple K output Lead wire : Fiberglass * Response time (reference values) : Approx.3.5 sec (90%) Typ. Model Code Model and Suffix Code Specifications Lead wire length (unit: mm) ST-100KST-100K1500 to 5000mm * 500 to 990mm (Specify 100mm each) 1000 to 5000mm (Specify 500mm each) Fiberglass Spade lugs for JIS standard "M3" size screw Ring lugs for JIS standard "M4" size screw Thermocouple connector (CSP01-K + CLP-A) Thermocouple connector (CMP01-K + CLP-B) No terminal lugs *terminal soldered Lead protection Lead wire termination EXB Y3 R4 TE1 TE3 N External Dimension Unit : mm ST-100K ST-100K1 50 40 30 40 2-4.3 Screw size : M4 10 12 2-3.3 Screw size : M3 2 20 Spring 16 Lead wuire 30 15 22 43 14 26.5 6.5 12 4 12 25.5 12 0.5 C1 0.5 6.5 14 18 11 3.5 59 Lead wuire 39.5 10 3 15 2 6 9 Spring 4 12 25.5 Rotating Roll Surface Temperature Measuring Sensors JBS-3898 Features JBS-3898 is a sensor for surface temperature measurement, and it is small and easily connectable. Pressed by the spring, a sensor touches to a measuring part and realizes a stable temperature measurement. Non contact type is capable of easy and accurate measurement for rotary roll and belt with shiny surface which is difficult to be measured. Specifications Thermocouple Type : Type K, Class 2 (JIS) Type T, Class 1 (JIS) Measuring accuracy : Type K ±2.5°C [0 to 50°C] ±(1.0°C + 0.03|t|) or ±0.045|t|, whichever is larger. [50 to 300°C] t: measuring temperature Type T ±2°C [0 to 50°C] ±(1.0°C + 0.03|t|) [50 to 100°C] t: measuring temperature Response time : Type K, Fiberglass lead wire 1.0 sec (Response of 63.2%). 3.6 sec (Response of 95.0%) Type K, Fluorocarbon polymers lead wire 1.2 sec (Response of 63.2%). 6.3 sec (Respose of 95.0%) Type T, Fluorocarbon polymers lead wire 2.0 sec (Response of 63.2%). 6.0 sec (Response of 95.0%) Operating temperature : Type K,0 to 300°C (Fiberglass lead wire) Type K,0 to 200°C (Fluorocarbon polymers lead wire) Type T,0 to 100°C (Fluorocarbon polymers lead wire) Contact plate : SUS304, Width 7mm,Thickness:0.15mm Lead wire : Fiberglass lead wire, Element diameter (0.32) Fluorocarbon polymers lead wire, Element diameter (0.2) Weight : 23g (Fiberglass lead wire, Lead length : 3m, Lead wire termination : Spade lugs for JIS standard "M3" size screw) 2 types are available (Right-rotary and left-rotary types) For directions of rotation and mounting of roller, we have right-rotary and left-rotary types. Top view For right-rotary For left-rotary Roller Measuring parts Measuring JBS-3898 parts (This is figure from upper side.) Roller JBS-3898 (This is figure from upper side.) Model Code Model and Suffix Code Specifications Lead wire length (unit: mm) JBS-3898 100 to 8000mm * 100 to 990mm (Specify 10mm each) 1000 to 8000mm (Specify 500mm each) EXB EXF Lead protection Fiberglass lead wire (Type K only) Fluorocarbon polymers lead wire Lead wire termination Spade lugs for JIS standard "M3" size screw Spade lugs for JIS standard "M4" size screw No terminal lugs *terminal soldered Thermocouple type Y3 R4 N Type K K T Type T Directions of rotaion R L For right-rotary For left-rotary External Dimension Unit : mm For right-rotary Lead wire termination Spade lugs Silicon Varnish Glass Tube 7 Soldered after welding 22 Lead wire (Element wire) 2 Rivet Silver brazing 15 ±0.2 20 Measuring side 45 8 SUS304 t=0.15 L 5 10 13 43.5 2-M4 41 44 General type • Sheathed Resistance Temperature Detectors Resistance Temperature Detector Platinum Resistance Temperature Detector (Pt100) Temperature Characteristic 3.5 Resistivity (Rt/RO) The value of metal resistance changes according to temperature change. This measuring element which utilizes a relationship between temperature and resistance is called Resistance Temperature Detectors (RTDs). Platinum, nickel, and copper are used as metals of RTDs, and utilizes a characteristic that the resistance increases as the temperature rises. Platinum is the most excellent element in accuracy and stability and is defined in "JIS" standard. Platinum is fragile compared with the other elements, be cautious about its usage at a place where vibrations and shocks will occur. All of our RTDs are platinum ones of the type Pt100. 3.0 2.5 2.0 1.5 1.0 0.5 Sheathed Resistance Temperature Detector Inside the thin stainless steel pipe, element is located, and then Stainless pipe is filled with a MgO. This type of sensor features in excellent responsiveness and vibration resistances. 0 -200 -100 0 100 200 300 400 500 600 650 Temperature (ºC) Terminal head type Sleeve type R-101(General type)/R-101S(Sheathed type) R-30,35(General type)/R-30S,35S(Sheathed type) R-111(General type)/R-111S(Sheathed type) No-sleeve type Metal connector type (Only for General type) R-90(General type)/R-90S(Sheathed type) R-102 ■ Sanitary type Resistance Temperature Detector Sanitary Sensors are able to keep cleanness of foreign matters and bacteria, users can relief to apply them in food, beverage, and chemical processing applications. Protection tube is #400 polish finishing. Ferrule cap and hexagon nut and linear cap are available. Protection tube material is SUS316. Electropolishing is available (Specify from "option" code). Ferrule cap Hexagon nut and Linear cap (Sheathed Resistance Temperature Detector) R-31S, R-36S 45 (Sheathed Resistance Temperature Detector) R-31RS, R-36RS Resistance Temperature Detectors : R-101/R-111 Red (A) Black (B) Black (B) d1 Serial number Heat shrink label tube L Specification label L1 40 L2 Hexagon Crimp Sleeve Filled with Epoxy Resin (MAX 120ºC) Lead wire termination Lead wire (3-wire system) Red Serial number label Specification label Heat shrink tube (A) Black (B) Black (B) L 40 120° Protection tube (SUS316) Argon welding d R - 101 - d - L1 - L - R - 111 - d - L1 - L2 - L - - - - - - - - - Diameter of protection tube Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Resistance temperature detector type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Length of protection tube Example :R-111-5-100-30-2000-EXA-Y-PDM-NG-N Example :R-101-5-100-2000-EXA-Y-PDM-NG-N Diameter of protection tube Resistance temperature detector type 3.0, 3.2, 4.0, 4.8, 5.0, 6.0, 8.0 -1: Specify length by “mm” (100mm or more, L1+L2=1,000mm or less) -2: Specify length by “mm” (25mm or more, L1+L2=1,000mm or less) • Length is 25mm without specification. Specify length by “mm” (100mm to 1,000mm) Length of protection tube • Please contact distributors regarding other length. Lead wire length Specify length by “mm” (100mm or more) • Please contact distributors regarding other length. Lead protection Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Lead wire termination Code Details Code Details No terminal lugs * terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1603-P) •See Page7 Resistance temperature detector type Measuring junction Mounting bracket Operating temperature Details Code 0 to 220ºC PDP Pt100 Middle Temperature Type (3.0 to 4.0) 0 to 350ºC PDM Pt100 Middle Temperature Type (4.8 or more) 0 to 500ºC PDH Pt100 High Temperature Type (4.8 or more) Code EXD EXE EXF Operating temperature -20 to +90ºC -55 to +180ºC 0 to 200ºC Details PVC (polyvinyl chloride) Silicone rubber Fluorocarbon polymers (FEP) Operating temperature Details Code PAP JPt100 Middle Temperature Type (3.0 to 4.0) 0 to 220ºC PAM JPt100 Middle Temperature Type (4.8 or more) 0 to 350ºC PAH JPt100 High Temperature Type (4.8 or more) 0 to 500ºC Code NG O Details Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Exposed Please contact with our distributors. Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) • Please contact distributors regarding other mounting bracket. Class : class B * Class A is available (Please specify when you order) Sleeve Dimension (d1) Element : Single element * Double element is available. Diameter of protection tube (Diameter of protection tube : 4.8 or more) 3.0 to 5.0 6.0 to 8.0 Lead (Please specify when you order) wire type Specifications Maximum temperature for use Diameter of protection tube 3.0 to 4.0 (Middle temperature type : Code PDP/PAP) 4.8 or more (Middle temperature type : Code PDM/PAM) 4.8 or more (High temperature type : Code PDH/PAH) • Stainless flexible lead wire is available Model Code : R-101F/R-111F MAX 120ºC Reference SUS304 Compensation lead wire (Fiberglass) For flexible lead wire, the dimension of the sleeve is 10 x 40mm. • No waterproof EXA,EXB,EXC EXD,EXE,EXF Operating temperature 0 to 220ºC 0 to 350ºC 0 to 500ºC 8×40 5 40 • Spring loaded type is available (Please specify when you order) • Material of protection tube Sleeve is Lead wire filled with epoxy (Compensation (MAX 120ºC) Spring (SUS304) lead wire) Sleeve 70 10×40 d1 d 120° -2 d1 Filled with Lead wire Epoxy Resin (3-wire system) (MAX 120ºC) Lead wire termination -1 L1 Hexagon Argon welding Protection Crimp tube (SUS304) Sleeve SUS316 is available. (Please specify when you order) L Dimensions for the spring loaded sleeve is as follows. • Protection tube 1.0 to 4.8 with extension lead wire EXC, EXD : 10 x 40mm • Protection tube 6.0 to 8.0 : 10 x 40mm • Except from the above: : 8 x 40mm 46 Resistance Temperature Detectors : R-102 Diameter of protection tube (d) : 4.0 or more Diameter of protection tube (d) : 3.0, 3.2 d 120° Argon welding d Lead wire Filled with Epoxy Resin (3-wire system) Protection tube (SUS304) Argon welding Lead wire termination Red (A) Black (B) Black (B) Serial number Heat shrink label tube 120° R - 102 - d - L1 - L - Hexagon Crimp (A) Black (B) Black (B) L R - 102 - d - L1 - L - - - - - Lead wire termination Lead wire (3-wire system) Red Serial number Heat shrink label tube L1 L L1 Protection tube (SUS304) - - - - Diameter of protection tube Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Resistance temperature detector type Length of protection tube Resistance temperature detector type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Example :R-102-3.2-100-2000-EXF-Y-PDM-NG-N Diameter of protection tube Length of protection tube Lead wire length Example :R-102-5-100-2000-EXA-Y-PDM-NG-N 3.0, 3.2 4.0, 4.8, 5.0, 6.0, 8.0 Specify length by “mm” (50mm to 500mm) • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) Code EXF Code Operating temperature Details Fluorocarbon polymers (FEP) 0 to 200ºC EXA EXB Lead protection EXC EXD EXE EXF Lead wire termination Resistance temperature detector type Measuring junction Mounting bracket Operating temperature Details Fiberglass with stainless steel (Diameter of protection tube : 4.8 or more) Fiberglass (Diameter of protection tube : 4.8 or more) PVC (polyvinyl chloride) with copper wire braided (Diameter of protection tube : 5.0 or more) PVC (polyvinyl chloride) (Diameter of protection tube : 5.0 or more) Silicone rubber (Diameter of protection tube : 5.0 or more) Fluorocarbon polymers (FEP) (Diameter of protection tube : 4.0 or more) 0 to 150ºC 0 to 150ºC -20 to +90ºC -20 to +90ºC -55 to +180ºC 0 to 200ºC Code Details Code Details No terminal lugs * terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1603-P) •See Page7 Code Details Operating temperature 0 to 220ºC PDP Pt100 Middle Temperature Type 0 to 220ºC PAP JPt100 Middle Temoerature Type Code PDP PDM PAP PAM Details Operating temperature Pt100 Middle Temperature Type (4.0) 0 to 220ºC Pt100 Middle Temperature Type (4.8 or more) 0 to 300ºC JPt100 Middle Temoerature Type (4.0) 0 to 220ºC JPt100 Middle Temperature Type (4.8 or more) 0 to 300ºC Code NG O Details Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Exposed Please contact with our distributors. Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) • Please contact distributors regarding other mounting bracket. Class : class B * Class A is available (Please specify when you order) Element : Single element Maximum temperature for use : 0 to 220ºC Specifications • Material of protection tube • Spring loaded type is available (Please specify when you order) Spring (SUS304) Reference 47 70 Lead wire L Class : class B * Class A is available (Please specify when you order) Element : Single element * Double element is available. (Diameter of protection tube : 8.0 or more) (Please specify when you order) Maximum temperature for use Operating temperature Diameter of protection tube 4.0 (Middle temperature type : Code PDP/PAP) 0 to 220ºC 4.8 or more (Middle temperature type : Code PDM/PAM) 0 to 300ºC SUS316 of protection tube is available. (Please specify when you order) Resistance Temperature Detectors : R-30/R-35 d Terminal head Protection tube (SUS304) Argon welding Specification label 120° (10 or more :Hemisphere) d 120° (10 or more :Hemisphere) Terminal head Specification label d Protection tube (SUS304) Argon welding Serial number label L1 Serial number label 60 PF3/8 PF1/2 L1 No lead wire R - 30 - d - L1 - - With lead wire R - 30 - d - L1 - L - - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead wire termination Resistance temperature detector type Sensing junction Mounting bracket With lead wire R - 35 - d - L1 - L Diameter of protection tube Length of protection tube Lead wire length Lead protection Example :R-30-5-100-PDM-NG-N (No lead wire) :R-30-5-100-2000-EXA-Y-PDM-NG-N (With lead wire) - - - Lead wire termination Resistance temperature detector type Sensing junction Mounting bracket Example :R-35-5-100-PDM-NG-N (No lead wire) :R-35-5-100-2000-EXA-Y-PDM-NG-N (With lead wire) 3.0, 3.2, 4.8, 5.0, 6.0 6.4, 8.0, 10.0, 12.0 4.8, 5.0, 6.0, 6.4, 8.0, 10.0, 12.0, 15.0 Length of protection tube Specify length by “mm” (100mm to 1,000mm) Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Lead wire length Specify length by “mm” (100mm or more) Lead wire termination No need to specify in case of without lead wire Diameter of protection tube Lead protection Resistance temperature detector type Measuring junction Mounting bracket 82 No lead wire R - 35 - d - L1 - - - • Please contact distributors regarding 21.7. Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Operating temperature -20 to +90ºC -55 to +180ºC Code Details Code Details No terminal lugs * terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1603-P) •See Page7 Operating temperature Details Code 0 to 220ºC PDP Pt100 Middle Temperature Type (3.0 to 4.0) 0 to 300ºC PDM Pt100 Middle Temperature Type (4.8 or more) 0 to 500ºC PDH Pt100 High Temperature Type (4.8 or more) Code NG O Code A B C Operating temperature Details Code PAP JPt100 Middle Temperature Type (3.0 to 4.0) 0 to 220ºC PAM JPt100 Middle Temperature Type (4.8 or more) 0 to 300ºC PAH JPt100 High Temperature Type (4.8 or more) 0 to 500ºC Details Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Exposed Please contact with our distributors. Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) • Please contact distributors regarding other mounting bracket. Specifications Class : class B * Class A is available (Please specify when you order) Element : Single element * Double element is available. (Only R-35) (Please specify when you order) Maximum temperature for use Operating temperature Diameter of protection tube 0 to 220ºC 3.0 to 4.0 (Middle temperature type : Code PDP/PAP) 0 to 300ºC 4.8 or more (Middle temperature type : Code PDM/PAM) 0 to 500ºC 4.8 or more (High temperature type : Code PDH/PAH) • Material of protection tube SUS316 is available. (Please specify when you order) Reference 48 d Resistance Temperature Detectors : R-90 Serial number label Argon welding Protection tube (SUS304) 120° L1 Adapter (SCK-1603-A) Plug (SCK-1603-P) 43 42 No lead wire R - 90 - d - L1 - - With lead wire R - 90 - d - L1 - L - - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead wire termination Resistance temperature detector type Sensing junction Mounting bracket Example :R-90-5-100-PDM-NG-N (No lead wire) :R-90-5-100-2000-EXA-Y-PDM-NG-N (With lead wire) Lead protection Lead wire termination No need to specify in case of without lead wire Diameter of protection tube Length of protection tube Lead wire length Resistance temperature detector type Measuring junction Mounting bracket 3.0, 3.2, 4.8, 5.0, 6.0, 8.0 Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Details PVC (polyvinyl chloride) Silicone rubber Code Details Code Details No terminal lugs * terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1603-P) •See Page7 Operating temperature Code Operating temperature Details Details Code PAP JPt100 Middle Temperature Type (3.0 to 4.0) 0 to 220ºC 0 to 220ºC PDP Pt100 Middle Temperature Type (3.0 to 4.0) PAM JPt100 Middle Temperature Type (4.8 or more) 0 to 350ºC 0 to 350ºC PDM Pt100 Middle Temperature Type (4.8 or more) Code NG O Code A B C Details Ungrounded * Exposed-junction type is available depending on specification such as shapes, environment of usage, etc. Exposed Please contact with our distributors. Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Class : class B * Class A is available (Please specify when you order) Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more) (Please specify when you order) Specifications Maximum temperature for use Diameter of protection tube 3.0 to 4.0 (Middle temperature type : Code PDP/PAP) 4.8 or more (Middle temperature type : Code PDM/PAM) • Material of protection tube SUS316 is available. (Please specify when you order) Operating temperature 0 to 220ºC 0 to 350ºC Connector Pin No. Single Element Double Element 3 1 3 Reference 2 Pin No. Details A 1 2 B 3 b SCK-1603- 2 4 1 6 5 Pin No. Details Pin No. Details A A 1 1 2 B 2 B 3 b 3 b SCK-1606- For connector for R-90, Connector manufactured by Sanwa Connector Laboratory Co., Ltd. is used as standard. Nanaboshi Electric Mfg brand is also available (Please specify when you order). Please specify in case of no need of the plug. 49 Operating temperature -20 to +90ºC -55 to +180ºC Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) Sheathed Resistance Temperature Detectors : R-101S/R-111S 40 L2 Lead wire termination d1 Red (A) Black (B) Black (B) Serial number Heat shrink label tube L Specification label L1 Lead wire (3-wire system) Filled with Epoxy Resin (MAX 120ºC) Specification label Lead wire termination Lead wire (3-wire system) Red Serial number label (A) Black (B) Black (B) Heat shrink tube L 40 120° d1 Filled with Epoxy Resin Sleeve (MAX 120ºC) Protection tube (SUS316) Argon welding d R - 101S - d - L1 - L - R - 111S - d - L1 - L2 - L - - - - - Diameter of protection tube - - - Lead wire termination Diameter of protection tube Lead wire termination Length of protection tube Resistance temperature detector type Lead wire length Sensing junction Lead wire length Sensing junction Lead protection Mounting bracket Lead protection Mounting bracket Length of protection tube Example :R-101S-4.8-100-2000-EXA-Y-PDM-NG-N Diameter of protection tube Length of protection tube Resistance temperature detector type Example :R-111S-4.8-100-30-2000-EXA-Y-PDM-NG-N 3.2, 4.8, 6.4, 8.0 -1: Specify length by “mm” (100mm or more, L1+L2=1,000mm or less) -2: Specify length by “mm” (25mm or more, L1+L2=1,000mm or less) • Length is 25mm without specification. Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Lead wire length Specify length by “mm” (100mm or more) Lead protection Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Lead wire termination Resistance temperature detector type Measuring junction Mounting bracket Code EXD EXE EXF Details PVC (polyvinyl chloride) Silicone rubber Fluorocarbon polymers (FEP) Operating temperature -20 to +90ºC -55 to +180ºC 0 to 200ºC Code Details Code Details No terminal lugs * terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1603-P) •See Page7 Operating temperature Code Operating temperature Details Details Code -200 to +100ºC PAL JPt100 Low Temperature Type -200 to 100ºC PDL Pt100 Low Temperature Type 0 to 350ºC PAM JPt100 Middle Temperature Type 0 to 350ºC PDM Pt100 Middle Temperature Type 0 to 500ºC PAH JPt100 High Temperature Type 0 to 500ºC PDH Pt100 High Temperature Type Code NG Code A B C Details Ungrounded Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) • Please contact distributors regarding other mounting bracket. Specifications Maximum temperature for use Diameter of protection tube 3.0 to 4.0 (Low temperature type : Code PDL/PAL) 4.8 or more (Middle temperature type : Code PDM/PAM) 4.8 or more (High temperature type : Code PDH/PAH) Sleeve Dimension (d1) Operating temperature -200 to +100ºC 0 to 350ºC 0 to 500ºC It is available to cover Fuluorine resin tube with φ4.8 protection tube (SUS316). Total Diameter becomes φ6.0. Model Code : R-101S/R-111S It is also available to do coating with R-101S whose MAX 120ºC tube is more than φ3.2. These model codes are R-101SC in this case. 3 8 Fuluorine Silicone SUS316 resin tube Sleeve (FEP) rubber Mgo Isolation Crimp (SUS304) tube Lead wire 45 MAX 200ºC L 3.2, 4.8 6.4, 8.0 8×40 10×40 EXA,EXB,EXC EXD,EXE,EXF • Stainless flexible lead wire is available • Fluor resin coating is available Reference Diameter of protection tube Lead wire type 5 40 d1 Class : class B * Class A is available (Please specify when you order) Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more) (Please specify when you order) 6 4.8 d 120° Protection tube (SUS316) L1 Argon welding Hexagon Crimp Hexagon Crimp Sleeve • Spring loaded type is available (Please specify when you order) Filled with Lead wire Epoxy Resin Spring (Compensation (MAX 120ºC) (SUS304) lead wire) Sleeve 70 SUS304 Compensation lead wire (Fiberglass) For flexible lead wire, the dimension of the sleeve is 10 x 45mm. • No waterproof L Dimensions for the spring loaded sleeve is as follows. • Protection tube 3.2 with extension lead wire EXE : 8 x 40mm • Protection tube 4.8 to 8.0 with extension lead wire : 8 x 45mm • Except from the above: : 10 x 45mm 50 Argon welding 120° Argon welding Terminal head Specification label Protection tube (SUS316) d d Sheathed Resistance Temperature Detectors : R-30S/R-35S Protection tube (SUS316) 120° Terminal head Specification label Serial number label L1 Serial number label 60 PF3/8 PF1/2 L1 No lead wire R - 30S - d - L1 - - - 82 No lead wire R - 35S - d - L1 - - - With lead wire R - 30S - d - L1 - L - With lead wire R - 35S - d - L1 - L - - - - Lead wire termination Resistance temperature detector type Sensing junction Mounting bracket Diameter of protection tube Length of protection tube Lead wire length Lead protection Diameter of protection tube Length of protection tube Lead wire length Lead protection - - - Lead wire termination Resistance temperature detector type Sensing junction Mounting bracket Example :R-30S-4.8-100-PDM-NG-N (No lead wire) Example :R-35S-5-100-PDM-NG-N (No lead wire) :R-30S-4.8-100-2000-EXA-Y-PDM-NG-N (With lead wire) :R-35S-5-100-2000-EXA-Y-PDM-NG-N (With lead wire) Diameter of protection tube 3.2, 4.8, 6.4, 8.0 4.8, 6.4, 8.0 Length of protection tube Specify length by “mm” (100mm to 1,000mm) Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) Lead protection Lead wire termination No need to specify in case of without lead wire Lead wire length Resistance temperature detector type Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Operating temperature Code Operating temperature Details Details Code -200 to +100ºC PAL JPt100 Low Temperature Type -200 to 100ºC PDL Pt100 Low Temperature Type 0 to 350ºC PAM JPt100 Middle Temperature Type 0 to 350ºC PDM Pt100 Middle Temperature Type 0 to 500ºC PAH JPt100 High Temperature Type 0 to 500ºC PDH Pt100 High Temperature Type Code NG Details Ungrounded Mounting bracket Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Class : class B * Class A is available (Please specify when you order) Element : Single element * Double element is available. (Only for R-35S) (Please specify when you order) Maximum temperature for use Diameter of protection tube Low temperature type : Code PDL/PAL Middle temperature type : Code PDM/PAM High temperature type : Code PDH/PAH • Fluor resin coating is available 6 4.8 It is available to cover Fuluorine resin tube with φ4.8 protection tube (SUS316). Total Diameter becomes φ6.0. It is also available to do coating with R-101S whose tube is more than φ3.2. These model codes are R-30SC/R-35SC in this case. Reference SUS316 Mgo Isolation 3 Fuluorine resin tube (FEP) L1 Operating temperature for regular use : 180ºC Maximum temperature : 200ºC Example : R-30SC-6.0-100-PDM-NG-N (No lead wire) • Please contact distributors regarding Fuluorine coating type. 51 Operating temperature -20 to +90ºC -55 to +180ºC Code Details Code Details No terminal lugs * terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1603-P) •See Page7 Measuring junction Specifications Details PVC (polyvinyl chloride) Silicone rubber Operating temperature -200 to +100ºC 0 to 350ºC 0 to 500ºC Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) Sheathed Resistance Temperature Detectors : R-90S Serial number label d Argon welding Protection tube (SUS316) 120° L1 Adapter (SCK-1603-A) Plug (SCK-1603-P) 43 42 No lead wire R - 90S - d - L1 - - With lead wire R - 90S - d - L1 - L - - - - - Diameter of protection tube Length of protection tube Lead wire length Lead protection Lead wire termination Resistance temperature detector type Sensing junction Mounting bracket Example :R-90S-4.8-100-PDM-NG-N (No lead wire) :R-90S-4.8-100-2000-EXA-Y-PDM-NG-N (With lead wire) Diameter of protection tube Length of protection tube No need to specify in case of without lead wire Lead wire termination Specify length by “mm” (100mm to 1,000mm) • Please contact distributors regarding other length. Specify length by “mm” (100mm or more) Lead wire length Lead protection 3.2, 4.8, 6.4, 8.0 Resistance temperature detector type Measuring junction Mounting bracket Operating temperature Details Code EXA Fiberglass with stainless steel 0 to 150ºC EXB Fiberglass 0 to 150ºC EXC PVC (polyvinyl chloride) with copper wire braided -20 to +90ºC Code EXD EXE Operating temperature -20 to +90ºC -55 to +180ºC Code Details Code Details No terminal lugs * terminal soldered Y Spade lugs for JIS standard "M3" size screw N R Ring lugs for JIS standard "M4" size screw M Metal connector (SCK-1603-P) •See Page7 Operating temperature Code Operating temperature Details Details Code -200 to +100ºC PAL JPt100 Low Temperature Type -200 to 100ºC PDL Pt100 Low Temperature Type 0 to 350ºC PAM JPt100 Middle Temperature Type 0 to 350ºC PDM Pt100 Middle Temperature Type 0 to 500ºC PAH JPt100 High Temperature Type 0 to 500ºC PDH Pt100 High Temperature Type Code NG Details Ungrounded Code A B C Details Fixed nipple (nut) Rotary nipple (nut) Fixed flange Code E N Details Compression fitting No bracket • Please contact distributors regarding other mounting bracket. Specifications Details PVC (polyvinyl chloride) Silicone rubber Specify size of mounting bracket when code is "A", "B", or "E". (See Page 6) Specify size of flange when code is "C". (See Page 6) Class : class B * Class A is available (Please specify when you order) Element : Single element * Double element is available. (Diameter of protection tube : 4.8 or more) (Please specify when you order) Maximum temperature for use Operating temperature Diameter of protection tube -200 to +100ºC Low temperature type : Code PDL/PAL 0 to 350ºC Middle temperature type : Code PDM/PAM 0 to 500ºC High temperature type : Code PDH/PAH Connector Pin No. Single Element Double Element 3 1 3 Reference 2 Pin No. Details A 1 B 2 b 3 SCK-1603- 2 4 1 6 5 Pin No. Details Pin No. Details A A 1 1 2 B 2 B 3 b 3 b SCK-1606- For connector for R-90S, Connector manufactured by Sanwa Connector Laboratory Co., Ltd. is used as standard. Nanaboshi Electric Mfg brand is also available (Please specify when you order). Please specify in case of no need of the plug. 52 Sanitary type Sheathed Resistance Temperature Detectors : R-31S/R-36S 8 Argon welding 120° Protection tube(SUS316) #400 polish finishing (Electrolytic polishing : Optional) Protection tube(SUS316) #400 polish finishing (Electrolytic polishing : Optional) Argon welding R - 31S - d - L1 - L2 - L2 (50) 70 L1 R - 36S - d - L1 - L2 - - - Resistance temperature detector type Ferrule cap type Ferrule cap material Optional (Electrolytic polishing) Diameter of protection tube Length of protection tube (L1) Length of Terminal head - ferule cap (L2) Argon welding PF3/8 L2 (50) L1 90 72 120° d 8 Ferrule cap Argon welding 8 7 Argon welding 5 5 d Argon welding Terminal head Terminal head Ferrule cap Diameter of protection tube Length of protection tube (L1) Length of Terminal head - ferule cap (L2) Example : R-31S-4.8-500-50-DMA-10S-1-E Details Code DMA Pt100 (Class A) DMB Pt100 (Class B) Resistance temperature detector type Ferrule cap type Ferrule cap material Optional (Electrolytic polishing) Example : R-36S-4.8-500-50-DMA-10A-2-E Details Code AMA JPt100 (Class A) AMB JPt100 (Class B) Details 8A *1 10A *1 15A *1 Ferrule cap type Code 8A 10A 15A Ferrule cap material Code 1 2 Details SUS304 SUS316L *1 Optional (Electrolytic polishing) Code E N Details Electrolytic polishing No electrolytic polishing Specifications Code 10S 15S 20S 25S Details 1.0S 1.5S 2.0S 2.5S Class : class A or B Element : Single element * Double element is available. (Only R-36S) (Please specify when you order) Specified current : 2mA Operating temperature: -40 to +200ºC B A 11 53 Details 3.0S *1 : 8A,10A,15A : Only SUS316 (Code :2) Ferrule cap dimensions Reference Code 30S A Size 8A,10A,15A 34 50.5 1S, 1.5S 64 2S 2.5S 77.5 3S 91 B 21.7 38.1 50.8 63.5 76.3 PF1/2 - - - Diameter of 3.2, 4.8, 6.4, 8.0 protection tube Length of Specify length by “mm” (100mm to 500mm) protection tube (L1) Length of Terminal 50mm (Standard) head - ferule cap (L2) Resistance temperature detector type 90 Sanitary type Sheathed Resistance Temperature Detectors : R-31RS/R-36RS Terminal head Argon welding d L2 (50) L1 120° Argon Protection tube(SUS316) welding #400 polish finishing (Electrolytic polishing : Optional) PF3/8 70 L2 (50) L1 R - 31RS - d - L1 - L2 - R - 36RS - d - L1 - L2 - - - Resistance temperature detector type Hexagon nut type Liner cap material Optional (Electrolytic polishing) Diameter of protection tube Length of protection tube (L1) Length of Terminal head - Linear cap (L2) 90 72 Argon Protection tube(SUS316) welding #400 polish finishing (Electrolytic polishing : Optional) 8 8 120° Terminal head 78 Argon welding 5 5 d Hexagon nut (SUS304), Liner cap Hexagon nut (SUS304), Liner cap Diameter of protection tube Length of protection tube (L1) Length of Terminal head - Linear cap (L2) 90 PF1/2 - - Resistance temperature detector type Hexagon nut type Liner cap material Optional (Electrolytic polishing) Example : R-36RS-4.8-500-50-DMA-15S-1-E Example : R-31RS-4.8-500-50-DMA-15S-1-E Diameter of 3.2, 4.8, 6.4, 8.0 protection tube Length of protection tube (L1) Specify length by “mm” (100mm to 500mm) Length of Terminal head - Liner cap 50mm (Standard) (L2) Resistance temperature detector type Details Code DMA Pt100 (Class A) DMB Pt100 (Class B) Details Code AMA JPt100 (Class A) AMB JPt100 (Class B) Details Details Code 25S 2.5S 30S 3.0S Hexagon nut type Code 10S 15S 20S 1.0S 1.5S 2.0S Liner cap material Code 1 2 Details SUS304 SUS316L Optional (Electrolytic polishing) Code E N Details Electrolytic polishing No electrolytic polishing Specifications Class : class A or B Element : Single element * Double element is available. (Only R-36RS) (Please specify when you order) Specified current : 2mA Operating temperature: -40 to +200ºC Liner cap Hexagon nut (SUS304) A L Size 1S 1.5S 2S 2.5S 3S A 33.8 47 60.5 74 87.5 L 11.5 11.5 11.5 11.5 11.5 Size 1S 1.5S 2S 2.5S 3S B Reference A 30 30 30 30 30 B 46 56 71 85 100 A Hexagon nut (SUS304) and Liner cap Liner cap Argon welding L1 Hexagon nut (SUS304) Argon welding L2 (50) 54 (Thermocouple) PFA (Fluororesin) coated temperature sensors FT-100 FR-100 (Resistance Temperature Detector) Temperature sensor with perfluoroalkoxy polymer resin coating (PFA) excels in chemical and moisture resistance. Measuring Point Measuring Point Thermocouple : FT-100 Resistance Temperature Detector : FR-100 Specifications FT-100 (Thermocouple) Type Thermocouple K, Class 1 FR-100 (Resistance Temperature Detector) Type Pt100, 3-wire system, Class A Measuring range Measuring range 0 to 200ºC Do not condensate except for the protection tube 0 to 200ºC Do not condensate except for the protection tube Measuring accuracy ±2.5°C (Immersion length : 100mm or more) Protection tube material PFA (fluororesin) Acceptable radius 15mm (Except 90mm from tip) for protection tube bending Lead wire diameter 1.0×1.6mm ±(0.15 + 0.002 | t |)°C (t:Measuring temperature) Measuring accuracy Specified current : 2mA (Immersion length : 100mm or more) Protection tube material PFA (fluororesin) Lead wire diameter 1.7mm Lead wire configure 0.1mm X 7 Lead wire configure 3.2mm X 1 Lead coating material PFA (fluororesin), Gray Lead coating material PFA (fluororesin), Green Application Cleaning Chemicals Gas Exhaust Pipe Battery electrolyte PFA coated temperature sensor PFA coated temperature sensor PFA coated temperature sensor Chemical liquid supplying device Environmental test chambers Thermal reaction PFA coated temperature sensor 500 400 300 200 100 PFA coated temperature sensor 55 (Thermocouple) PFA (Fluororesin) coated temperature sensors FT-100 FR-100 (Resistance Temperature Detector) External Dimensions Unit : mm Thermocouple FT-100 Max.10000 Protection tube L1=250 to 5000 (*1) 15 (PFA filling) 15 (PFA filling) 80 4 4 4 2.5 18 (PFA filling) 50 No terminal lugs (Terminal soldered) (1.0X1.6) 55 (4) Lead wire L2=500 to 9000 (*1) +(Green) - (White) Protection tube (PFA) Specification label PFA coating lead wire (0.32/1X2) (Red) Spade lugs (Black) termination +(Green) - (White) (Red) *1: Total lead length of the protection tube length can be manufactured in 10000mm (10m) below. +(Green) Ring lugs (Black) termination - (White) Resistance Temperature Detector FR-100 Max.10000 Lead wire L2=500 to 9000 (*1) Protection tube L1=250 to 5000 (*1) 15 (PFA filling) 15 (PFA filling) 80 50 1.7 4 4 4 12 (PFA filling) 4 55 A(Red) B(White) B(White) Specification label No terminal lugs (Terminal soldered) Protection tube (PFA) *1: Total lead length of the protection tube length can be manufactured in 10000mm (10m) below. PFA coating lead wire (0.1/7×3) Model Code Thermocouple FT-100 Specifications Resistance Temperature Detector FR-100 Model and Suffix Code FT-100 - K- 42- A- Thermocouple type Thermocouple K, Class 1 Diameter of protection tube 4 Protection tube PFA (Fluororesin) 250mm Length of protection tube 500mm (L1) to (Each 500mm) 5000mm *2 500mm to (Each 500mm) Lead wire length 5000mm (L2) 5000mm *2 to (Each 1000mm) 9000mm Lead wire termination No terminal lugs *terminal soldered Spade lugs for JIS standard "M3" size screw Spade lugs for JIS standard "M4" size screw Ring lugs for JIS standard "M3" size screw Ring lugs for JIS standard "M4" size screw - -AW - Resistance temperature detector type Diameter of protection tube Protection tube K 42 A 250 500 to 5000 W Y3 Y4 FR-100 Pt100, Class A, Middle temperature type 4 PFA (Fluororesin) 250mm 500mm (L1) to (Each 500mm) 5000mm *3 500mm to (Each 500mm) Lead wire length 5000mm (L2) 5000mm *3 to (Each 1000mm) 9000mm Lead wire No terminal lugs termination * terminal soldered water cleaning & Pure water cleaning Pure Clean packing Length of protection tube 500 to 5000 5000 to 9000 Model and Suffix Code Specifications - DPA - 42- A - - -AW - DPA 42 A 250 500 5000 500 to 5000 5000 to 9000 N AW *3 : Total length of Protection tube and lead wire can be up to 10000mm (10m). R3 R4 water cleaning & Pure water cleaning Pure Clean packing AW *2 : Total length of Protection tube and lead wire can be up to 10000mm (10m). 56 Reference information Thermocouple (1) Thermocouple element type Thermocouple elements K(CA), J(IC), T(CC), E(CRC), N, R, S, B are available. Please find the below chart and choose them according to applications. Thermocouple classes are standard as class 2 and an accurate type as class 1. (see the differences of temperature allowance section) All standard types are class 2. (Only standard type for B is class 3) JIS C1602-1995 Symbol (+) side wire (-) side wire Element wire diameter (mm) Operating temperature range (°C) -200 0 200 400 600 800 1.00 K (CA) Chromel Alumel 1000 850°C 900°C 3.20 1000°C 400°C 0.65 1.00 Iron Constantan 450°C 500°C 1.60 2.30 550°C 3.20 T (CC) Copper Constantan 600°C 0.32 200°C 0.65 200°C 250°C 1.00 300°C 1.60 450°C 0.65 E Chromel Constantan (CRC) 500°C 1.00 550°C 1.60 600°C 2.30 3.20 700°C 850°C 0.65 950°C 1.00 Nicrosil N Nisil 1400 750°C 1.60 2.30 J (IC) 1200 650°C 0.65 1050°C 1.60 1100°C 2.30 3.20 1200°C Platinum 1400°C 0.50 Rhodium13% Platinum 1400°C Platinum 0.50 S Platinum Rhodium10% *1 Platinum Platinum 1500°C B Rhodium30% Rhodium6% 0.50 °C *1 Maximum operating temperature is normal operating temperature limit (temperature limit for continuous operation). For overheating use limitation (temperature limitation for a short time use for an unavoidable situation), please find JIS standards (JIS C1602). Consider the above chart only as a guide. Operating temperature limit is subject to change dependent upon the types of the protection tube. For B type, measurement below 600°C is out of the tolerance range. R (2) Tolerance to temperature Type K J T E N R,S B JIS C1602-1995 Class 1 Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance Class 3 -40°C to +375°C ±1.5°C +375°C to +1000°C ±0.004•|t| -40°C to +375°C ±1.5°C +375°C to +750°C ±0.004•|t| -40°C to +333°C ±2.5°C +333°C to +1200°C ±0.0075•|t| -40°C to +333°C ±2.5°C +333°C to +750°C ±0.0075•|t| -167°C to +40°C ±2.5°C -200°C to -167°C ±0.015•|t| -40°C to +125°C ±0.5°C +125°C to +350°C ±0.004•|t| -40°C to +133°C ±1°C +133°C to +350°C ±0.0075•|t| -67°C to +40°C ±1°C -200°C to -67°C ±0.015•|t| -40°C to +375°C ±1.5°C +375°C to +800°C ±0.004•|t| -40°C to +333°C ±2.5°C +333°C to +900°C ±0.0075•|t| -167°C to +40°C ±2.5°C -200°C to -167°C ±0.015•|t| -40°C to +375°C ±1.5°C +375°C to +1100°C ±0.004•|t| -40°C to +333°C ±2.5°C +333°C to +1200°C ±0.0075•|t| -167°C to +40°C ±2.5°C -200°C to -167°C ±0.015•|t| 0°C to +1100°C ±1°C 0°C to +600°C ±1.5°C +600°C to +1600°C ±0.0025•|t| Temperature range Tolerance Temperature range Tolerance Temperature range Tolerance • |t| is a value which represents regardless of + or - symbols of temperature (°C). 57 Class 2 +600°C to +1700°C ±0.0025•|t| +600°C to +800°C ±4°C +800°C to +1700°C ±0.005•|t| Reference information Resistance Temperature Detector (1) Resistance Temperature Detector Type Platinum RTD (resistance temperature detector) can be divided into either Pt100 or JPt100 (former). It is more often used for low temperature applications than thermocouples, and has a high accuracy. On the other hand, it is not suitable in a situation where the responsiveness and measurement of surface or tiny spaces are required. Pt100 classes are either B as standard or A as accurate. For standard type, its class is B and its specified current is 2mA. Elements L, M, and H meet JIS C1604-1997 whereas "P" doesn't. Operating temperature range (°C) Specifications Type -200 0 L (Low Temperature Type) 200 600 P General type (Middle Temperature (3 to 4) Pt100 Type) JPt100 M Sheathed type (Middle Temperature General type(4.8 to 8) Type) 220°C 350°C Sheathed type General type (5 to 8) (High Temperature Type) 800 100°C Sheathed type H 400 650°C (Sheathed type or JPt100 : Up to 500°C) Consider the above chart only as a guide. (2) Tolerance to temperature Class Class A Class B JIS C 604-1997 Tolerance (°C) ±(0.15+0.002|t|) ±(0.3+0.005|t|) • |t| is a value which represents regardless of + or symbols of temperature (°C). Measuring temperature (°C) -200 -100 0 100 200 300 400 500 600 650 Tolerance Class A (°C) Class B ±0.55 ±1.3 ±0.35 ±0.8 ±0.15 ±0.3 ±0.35 ±0.8 ±0.55 ±1.3 ±0.75 ±1.8 ±0.95 ±2.3 ±1.15 ±2.8 ±1.35 ±3.3 ±1.45 ±3.6 700 800 850 ±3.8 ±4.3 ±4.6 ● Protection Tube SUS304, SUS316(for sheath), and Nicrobell are available as materials for the protection tube for standard type. It is available to select its material based on measured objects and measurement conditions. <Normal operating temperature limits> <Sheathed type> Diameter Thermocouple Protection tube K J T N SUS316 SUS310S Inconel Nicrobell SUS316 SUS316 Nicrobell JIS C 1605,(Nicrobell is out of JIS standard) 1.0 1.6 3.2 4.8 6.4 8.0 650°C 650°C 650°C 650°C 750°C 750°C 900°C 450°C 300°C 1000°C 450°C 300°C 1000°C 1100°C 650°C 350°C 1100°C 800°C 800°C 900°C 1100°C 750°C 350°C 1100°C 800°C 800°C 1000°C 1150°C 750°C 350°C 1150°C 900°C 900°C 1050°C 1200°C 750°C 350°C 1200°C (1) Special Protection Tube Metal protection tube Material Sandvik P4 (SUH446) Operating temperature for regular use (°C) Maximum temperature (°C) 1000°C 1200°C Titanium 250°C 500°C Cast Iron 700°C 800°C 180°C 200°C Fluor resin coating Features Excellent heat resistance and contained 27% chromium steel. Excellent salt-bath, melted metal, and acid resistance under high temperature. It can be used for sulfate containing reducing flame. Extremely excellent corrosion resistance, however this feature will be fragile under high temperature by oxidization. Extreme mechanical resistance. Fluor resin (FEP) coating with SUS316 sheath. Incredible chemical resistance under low temperature. Non-metal protection tube Material Operating temperature for regular use (°C) Maximum temperature (°C) 600°C Hard glass 500°C Silica glass 1000°C High alumina Ceramic tube Pure sintering alumina Zirconia 1400°C 1500°C 1450°C 1550°C 1700°C 1900°C 1900°C 2100°C Silicon carbide 1500°C 1700°C Silicon nitride 1200°C 1600°C Ceramic JIS Special 1600°C Ceramic JIS Type 1 Ceramic JIS Type 2 1500°C 1400°C Features Heatproof temperature limit is low. Fragile to thermal and mechanical shock and has a resistance to alkaline and acid. Has a resistance to sudden cooling and heating, Meanwhile, its strength is small. Vulnerable to alkaline, and resistant to acidity. Airtightness is deteriorated in hydrogen and reducing atmosphere. Incredible air proof. Melted metal and combustion gas resistance. Vulnerable to metallic oxide and alkaline. Incredible air proof. It is a neutral refractory. Melted metal, glass, and leady slag resistant. Vulnerable to thermal shock. It is thermal resistant and air proof. Excellent resistance to corrosion from glass and metallic slag. Good electrical and thermal conductivity. Withstand sudden heating, cooling, and oxidizing for its massive thermal strengthens. Excellent corrosion resistance to non-ferrous metals. Its thermal shock resistance is also excellent. Available to be stable measurement in a oxidized, reducing atmosphere, and high vacuum ambient environment. Excellent thermal and corrosion resistance. Good thermal characteristics. Less thermal softening and good thermal shock resistant. • Temperature for regular use and maximum temperature vary dependent upon the diameter of the protection tube. 58 Reference information Lead Wire : Compensation cable (Thermocouple), Copper wire (Resistance temperature detector) Compensation cable is used for thermocouple. Copper wire is used for RTD. There are other types of the lead wire such as glass fiber (EXB), vinyl coating(EXD) and so on. Please specify its type. To use the copper lead wire for thermocouple result in inaccurate temperature measurement. Characteristics of lead wire should be same as the element of thermocouple. Copper lead wire is used for RTD. Pay attention for wiring due to three-wires. Make sure that a resistance value of each wire is balanced. Below chart is the plain specification for each compensation lead wire. JIS C 1610-1995 Type Applications Standard KCC-G K J For heatresistive KCB-H Standard JX-G For heatresistive JX-H Standard TX-G For heatresistive TX-H Standard EX-G *1 Composition of core Code (JIS) Contact point Shearh compensation Material *2 Color temperature (°C) (+) Side (-) Side Copper 0.3 × 7 Alloy of Copper and Nichel 0.3 × 7 Vinyl Iron 0.3 × 7 Alloy of Copper and Nichel 0.3 × 7 Fiberglass Iron 0.3 × 7 Alloy of Copper and Nichel 0.3 × 7 Copper 0.3 × 7 Alloy of Copper and Nichel 0.3 × 7 0 to 100 Blue NX-G Yellow -25 to 200 ±140 Brown -25 to 100 ±60 Purple -25 to 200 ±200 Pink -25 to 200 ±100 Fiberglass Vinyl Vinyl Alloy of Nichel and Chrome Alloy of Copper and Nichel 0.3 × 7 0.3 × 7 Standard ±100 0 to 150 Fiberglass E EX-H *3 Vinyl T For heatresistive Error (μV) Fiberglass Vinyl Alloy of Nichel and Chrome Alloy of Nichel and Silicon 0.3 × 7 0.3 × 7 N For heatresistive NX-H Fiberglass Standard RCM-G Vinyl For heatresistive RCM-H Standard SCA-G Vinyl For heatresistive SCA-H Fiberglass Standard BC-G R Alloy of Copper and Nichel 0.3 × 7 Copper 0.3 × 7 Fiberglass Black 0 to 100 Gray 0 to 100 ±30 S B Copper 0.3 × 7 Copper 0.3 × 7 Vinyl *4 *1:0.65 ×4 wires is available for both (+) and (-). *2:Codes and types for external material (Coating) is based on JIS. Please refer to the below chart for the other types. *3:It is concerinig temperature of the junction with element and compensation cable. *4:Tolerance value is not specified since a material for + core wire and - core wire is identical. Compensation cable JIS C 1610-1995 (EXE, EXF is out of JIS standard) Composition of Compensation cable Insulation Sheath Core wire Operating temperature Details Code EXA For heat-resistive, Fiberglass with stainless steel EXB For heat-resistive, Fiberglass EXC For standard, PVC (polyvinyl chloride) with copper wire braided EXD For standard, PVC (polyvinyl chloride) EXE For heat-resistive, Silicone rubber EXF For heat-resistive, Fluorocarbon polymers (FEP) 0 to 150°C -20 to +90°C (KCB,RCA,SCA,BC : 0 to 90°C) -55 to +180°C 0 to 200°C Responsiveness of sensors It takes a certain time for measuring junction of thermocouple or element of RTD to reach the same temperature with measuring object. The shorter the pipe is, the faster the response is. Meanwhile mechanical resistance becomes weaken. It is important to select a sensor according to purpose and condition. Please refer to following chart as a guide. Response time (Atmospheric temperature to boiling water) Reference values Type Thermocouple (General type) Sheathed Thermocouple 59 3.2 5.0 1.0 1.6 3.2 4.8 8.0 63.2% 95.0% 0.3 sec 0.9 sec 0.8 sec 2.6 sec 0.05 sec 0.2 sec 0.15 sec 0.6 sec 0.5 sec 1.8 sec 1.0 sec 2.6 sec 2.7 sec 10.7 sec Reference values Type Resistance temperature detector (General type) Sheathed resistance temperature detector (General type) 3.0 5.0 6.0 8.0 3.2 4.8 8.0 63.2% 95.0% 3.6 sec 9.2 sec 5.5 sec 15 sec 7.1 sec 19 sec 11.8 sec 33 sec 3.2 sec 8.7 sec 4.2 sec 11.5 sec 8.7 sec 21 sec Temperature sensor specification check sheet (For General type and Sheathed type) Please make a copy of this specification check sheet and send it to our distributors. Check Specifications Check Item Reference page Protection tube type Page 3 to Page 4 Type Page 11 to Page 27 (Thermocouple) Page 45 to Page 54 (Resistance temperature detector) Operating temperature General type Sheathed type NICROBELL sheathed type Thermocouple K J T E N R B S PLII W5Re/W26Re Grounded (Standard) Ungrounded Exposed Single element (Standard) Double element Class 2 (Standard) Class 1 Class 3 (Type B) Resistance Temperature Detector (RTD) Single element (Standard) Double element Class B (Standard) Class A Grounded (Standard) Ungrounded Normal : °C °C Maximum : 90° bend type (Please check one out of 2 from the following pictures) Straight type (Please check one out of 6 from the following pictures) Length of protection tube (L1) Diameter of protection tube (d) mm L1 d d L1 d d L1 L2 L1 L1 With spring loaded d Page 45 to Page 54 (Resistance temperature detector) L2 L1 Page 11 to Page 27 (Thermocouple) d Shape d Diameter of protection tube (d) L1 mm mm Length of protection tube (L1) (L2) L1 d With spring loaded Other: please draw external view With spring loaded Optional With stainless flexible lead wire Fluor resin coating Other No bracket Fixed flange JIS K A or Mounting Bracket B Page 6 G (P.F) Compression fitting Taper screw R(PT) Lead protection Page 59 Lead wire length Page 11 to Page 54 Lead wire termination Fixed nipple (nut) (Check either parallel or taper screw) Rotary nipple (nut) (Check either parallel or taper screw) Parallel screw G (PF) Taper screw R (PT) Page 7 to Page 8 Other requests or environments of usage Measuring object or application (for reference) Fiberglass with stainless steel PVC (polyvinyl chloride) R (P.T) Other Fiberglass Silicone rubber PVC (polyvinyl chloride) with copper wire braided Fluorocarbon polymers (FEP) mm No terminal lugs *terminal soldered Spade lugs (M3 size) Ring lugs (M4 size) Metal connector Plug Thermocouple connector Receptacle Plug Other Jack Company Name Name Country Address E-mail Address Phone Number 60 Safety Warning • This product is intended for use with industrial machines, test and measuring equipment. It is not designed for use with medical equipment. • If it is possible that an accident may occur as a result of the failure of the product or some other abnormality, an appropriate independent protection device must be installed. Caution for the export trade All transactions must comply with laws, regulations, and treaties. Caution for imitated products As products imitating our product now appear on the market, be careful that you don't purchase these imitated products. We will not warrant such products nor bear the responsibility for any damage and/or accident caused by their use. R (RIKA KOGYO CO.,LTD) HEAD OFFICE : 16-6, KUGAHARA 5 CHOME OHTA-KU TOKYO 146-8515 JAPAN PHONE : 03-3751-9799 ( +81 3 3751 9799 ) Email : info@rkcinst.co.jp FAX : 03-3751-8585 ( +81 3 3751 8585 ) http://www.rkcinst.com/ CSEN10-E Printed in Japan : MAY.2015 All Right Reserved