1 Introduction
The ARISO LP1 Contact Connector is an M12 style contactless connector system designed
to connect sensors without a galvanic connection. It is able to transfer up to 6 W from the
ARISO Power Transmitter (Tx) to the ARISO Power Receiver (Rx). At the same time it
provides a uni-directional data connection from the Power Receiver (Rx) to the Power
Transmitter (Tx).
2 Evaluation Kit
This instruction cover the installation and connection of the ARISO evaluation kit for M12 style
contactless connectors meant to be used in combination with sensors. This evaluation kit
contains two connector parts (one ARISO Power Transmitter Tx and one ARISO Power
Receiver Rx) together with a data carrier containing the ARISO Design Objectives, the
Customer Drawing and this User Guide.
Figure 1: Evaluation Kit
ARISO LP1 Evaluation Kit User Guide
2/8
July 2013
ARISTO EVALUATION KIT
User Guide
2.1
408-78038
Rev. B
Product Part Number
Table 1: Product Part No.
Product Part No.
2229389-1
2229389-2
2.2
Product Name
GPIO KIT
ARISO LP1 Digital Evaluation Kit
0-10V ANALOG KIT
ARISO LP1 Analog Evaluation Kit
Remarks
ARISO LP1 D = coupler for up
to eight digital sensors
ARISO LP1 A = coupler for up
to four analog sensors
Content
Table 2: Content of the Evaluation Kit
Product Part
No.
2173736-1
2173736-3
Product Name
2173736-2
2173736-4
ARISO LP1 Rx
Power
Receiver
ARISO LP1 Tx
Power
Transmitter
Document
2.3
Remarks
Content:
User Guide :
Customer Drawing
Design Objective
Customer Drawing
Dimensions and material specification for transmitter (Tx) and Receiver (Rx) can be found in
the following customer drawings:
PN 2173736-1
PN 2173736-2
PN 2173736-3
PN 2173736-4
ARISO LP1 Tx GPO
ARISO LP1 Rx GPI
ARISO LP1 Tx 0-10V
ARISO LP1 Rx 0-10V
ARISO LP1 Evaluation Kit User Guide
3/8
July 2013
ARISTO EVALUATION KIT
408-78038
User Guide
2.4
Rev. B
Product Specification
The targeted performance results (Design Objectives) for the M12 style ARISO LP1
Contactless Couplers can be found in Design Objective 108-19449.
3 Wiring
3.1
Electrical Wiring
Table 3 and 4 give the pin numbering of the Male and Female Connectors that are attached
to the cable end of the Power Transmitter and Power Receiver. The wiring indication for the
Power Transmitter (Tx) and Power Receiver (Rx) is given in table 5 (Digital GPIO variant) and
table 6 (Analog 0-10V variant).
Table 3: Pin numbering Male Connector
Table 4: Pin numbering Female Connector
ARISO LP1 Evaluation Kit User Guide
4/8
July 2013
ARISTO EVALUATION KIT
408-78038
User Guide
Rev. B
Table 5: Digital GPIO (General Purpose Input/Output) variant
Color
Black
White/Green
White/Blue
Orange
Green
White/Brown
Brown
Blue
White/Orange
Red
N.C.
BRAID
Pin number
1
2
3
4
5
6
7
8
9
10
11
12
Power Transmitter (Tx) /
Data Receiver
Ground
GPO #7
GPO #5
GPO #2
GPO #3
GPO #8
GPO #4
GPO #1
GPO #6
+24V DC
Power Receiver (Rx) /
Data Transmitter
Ground
GPI #7
GPI #5
GPI #2
GPI #3
GPI #8
GPI #4
GPI #1
GPI #6
+24V DC
EARTH
EARTH
Power Transmitter (Tx) /
Data Receiver
Ground
0-10Vout #3
0-10Vout #1
0-10Vgnd #3
0-10Vgnd #2
0-10Vgnd #4
0-10Vout #2
0-10Vout #4
0-10Vgnd #1
+24V DC
Power Receiver (Rx) /
Data Transmitter
Ground
0-10Vin #3
0-10Vin #1
0-10Vgnd #3
0-10Vgnd #2
0-10Vgnd #4
0-10Vin #2
0-10Vin #4
0-10Vgnd #1
+24V DC
EARTH
EARTH
Table 6: PLC Analog 0-10V variant
Color
Black
Green
Blue
White/Green
White/Orange
White/Brown
Orange
Brown
White/Blue
Red
N.C.
BRAID
Pin number
1
2
3
4
5
6
7
8
9
10
11
12
ARISO LP1 Evaluation Kit User Guide
5/8
July 2013
408-78038
ARISTO EVALUATION KIT
User Guide
3.2
Rev. B
System Connections
Total system connection for a digital setup.
24Vdc
Gnd
24Vdc
Gnd
GPO #1
GPO #2
GPO #3
GPO #4
GPO #5
GPO #6
GPO #7
GPO #8
Power
Gnd
GPO #1
GPO #2
GPO #3
GPO #4
GPO #5
GPO #6
GPO #7
GPO #8
Digital out
Digital Sensor
10k
Digital PLC
Module
Gnd
ARISO LP1 Tx
GPIO variant
ARISO LP1 Rx
GPIO variant
Figure 2: Digital type GPIO wiring diagram.
Note that each used digital output should be terminated with a 10k resistor to Gnd.
Note that the digital outputs are not short circuit proof, the maximum allowable current is 25
mA
Total system connection for an analog setup.
24Vdc
Gnd
Analog PLC
Module
24Vdc
Gnd
Power
Gnd
0-10Vout #1
0-10Vgnd #1
0-10Vin #1
0-10Vgnd #1
Analog out
Gnd
0-10Vout #2
0-10Vgnd #2
0-10Vin #2
0-10Vgnd #2
Analog Sensor
0-10Vout #3
0-10Vgnd #3
0-10Vin #3
0-10Vgnd #3
0-10Vout #4
0-10Vgnd #4
0-10Vin #4
0-10Vgnd #4
ARISO LP1 Tx
0-10V variant
ARISO LP1 Rx
0-10V variant
Figure 3: Analog PLC 0-10V wiring diagram.
ARISO LP1 Evaluation Kit User Guide
6/8
July 2013
ARISTO EVALUATION KIT
408-78038
User Guide
Rev. B
4 Mounting
The ARISO LP1 is intended to be mounted using the M12 x 1 mm thread on the enclosure
which can be used to mechanically attach the units to its application.
Evaluation kit pair matching for optimum wireless data transfer
Each ARISO Power Transmitter Tx is matched with its Power Receiver Rx
coupler. Please note the unique 12-digit serial numbers marked on the
enclosure.
Distance between Transmitter (Tx) and Receiver (Rx) from metal
Each ARISO Power Transmitter (Tx) and Receiver (Rx) can be used to transfer
power through non-metallic objects.
Metallic objects, depending upon their size, can affect the operation of the power
link. It should be ensured that the tip of the Tx and Rx units enclosed by a plastic
cap is located at least 25 mm from metal.
Distance between adjacent Transmitter and Receiver pairs
The ARISO Power Transmitter pairs (Tx & Rx) can be used adjacent to each
other depending upon the application power and data requirements.
The minimum separation of 60 mm will ensure correct operation in most cases.
5 Specification Summary
Note: for a detailed overview of the product specification see document 108-19449.
5.1
Power Interface
Input voltage
Output voltage
Maximum output power
Metal clearance
Short circuit protection
Over-temperature protection
5.2
Digital Data Interface
Number of channels
Output structure
Maximum output current
Impedance level HIGH
Impedance level LOW
5.3
24V ± 5%
24V ± 5%
6W (distance < 2mm, no misalignment)
25 mm (distance of Front End to nearest metal surface)
Yes
Yes
8
PNP
25mA
< 1Ω
> 1MΩ
Analog Data Interface
Number of channels
Input range
Resolution
Minimum load impedance
4
0-10V
12bit
> 1kΩ
ARISO LP1 Evaluation Kit User Guide
7/8
July 2013
ARISTO EVALUATION KIT
408-78038
User Guide
Rev. B
6 Safety notices
Usage:
Do not use this product in any manner not specified. The protective features of this product
may be impaired if it is used in a manner not specified in the operation instructions.
Before applying power:
Verify that all safety precautions are taken. Make all connections to the unit before applying
power. Note the instrument's external markings described under “Safety Symbols”.
Fuses:
The instrument contains internal fuses, which are not customer accessible.
Do not modify the instrument:
Do not install substitute parts or perform any unauthorized modification to the product.
In case of damage:
Do not use the evaluation kit if it has damage or defect.
7 For more information Contact
Jens Schumacher, Marketing Manager
E-mail: jens.schumacher@te.com
Phone: +64412049645
Masaaki Harasawa,
E-mail: harasawa.masaaki@te.com
Phone: +81449005016
ARISO LP1 Evaluation Kit User Guide
8/8
July 2013
Download