C1883US - Lumascape

advertisement
1300 Industrial Road, Unit #19
San Carlos, CA 94070
FREE CALL 1-866-695-5862 US & Canada
info@lumascape.com
LS853LED
Ingrade
0-10 V
OPTIONAL
OPTIONAL
OPTIONAL
PWM DIM
IP68
IK10
OPTIONAL
The LS853LED is a full featured, shallow depth ingrade luminaire featuring lumen output
and efficacy exceeding metal halide. As an inherently protected luminaire it can be used
in interior spaces and immediately adjacent to combustible materials (such as wood
decking, etc). Dimming options include 0-10 V and PWM protocols, with various power
input options, including 120-277 V. In addition, internal rotation and tilt adjustability
ensures the most efficient light delivery can be set according to site conditions.
Specifications
Lamp Source
16 W or 20 W LED
□ White (4 300 K typical)
■ Warm white (3 000 K typical)
■ Blue (470 nm)
Other colors by request
RGB
Approved Use
Lumen Maintenance
(L70)
Suitable for wet locations
Suitable for use in poured concrete
Inherently protected
LS853LED
with round flush cover
>60,000 hrs
Limited by TM-21 x6 rule
360o
Control Options
0-10 V
PWM
IP Rating
IP68
Construction
316 marine grade stainless steel
Installation Types
Pre-Installation Blockout
Concrete pour, drive-over & general use
applications
20°
20°
Direct Burial
Landscapes, planters & special applications
(consult factory)
Drive-over
With OptiClear™ lens and pre-installation
blockout (LS6052-K or LS6052-K-SP)
Static Load Rating
8 140 lb (3 700 kg) with OptiClear™ lens and preinstallation blockout (LS6052-K or LS6052-K-SP)
(Load applied to center of glass across a 2" diameter area)
Impact Rating
IK10 with OptiClear™ lens
Standard Inclusions
Teflon coated cover screws
MicroAntiLeach™ wire entry
Accessories
LS6052-K/LS6052-K-SP Pre-installation blockout
Remote Transformers / Refer to Technical Data section
for application specific options
Power Supplies
Order separately
Ambient Operating
Temperature
16 W
20 W
-22 °F to 104 °F (-30 °C to +40 °C)
-22 °F to 122 °F (-30 °C to +50 °C)
Surface Temperature
≤113 °F (45 °C)
Photometrics
Refer to www.lumascape.com
Any luminaire can become hot - take care with appropriate use and placement
www.lumascape.com
C1883US 6 Sep 2013
LS853LED Pre-Installation Blockout
Ingrade
Why Use LS6052-K Pre-Installation Blockout?
Why Use LS6052-K-SP Pre-Installation Blockout?
The LS6052-K acts as a blockout, and is intended for installation
before the luminaire, however it has other special functions. To
simplify the installation, every LS6052-K is supplied complete with a
4-way, ¾" PVC junction box, inside which the installer can make all
necessary connections, and allows the completion of all wiring even
before the luminaire arrives on site. This method also ensures the
luminaire itself is not damaged during concreting or other site works.
Note: The junction box remains serviceable after installation.
To complete the installation, Lumascape provides an IP68 connector,
enabling a tool-free final connection from the luminaire to the branch
circuit. In addition, this connector is readily detachable, allowing for
off-site maintenance.
The LS6052-K-SP pre-installation kit (order separately) is ideal for use
in applications where maximum flexibility for the type and location of
branch circuit connections are required or where exact site conditions
may be unknown. The LS6052-K-SP is also for use with all applications
requiring a color changing or dimmable lighting scheme. For use with
the LS6052-K-SP, Lumascape provides the LS853LED complete with
6.5' of factory-installed hookup wire or an SOOW cord (both options
include a MicroAntiLeach™ seal). This provides the installer with
greater flexibility to determine the type and location of the branch circuit
connection. This option is also 100% hard-wired, and does not feature
the IP68 detachable couplings for off-site maintenance. All aspects of
the luminaire itself are still field serviceable.
Connection Type '85' for LS6052-K Pre-Installation Blockout
Lens Options
94
6.
m
m
(1
76
Ø
)
”
OptiClear™ Glass
Glass of very high
optical purity and load
strength. Suitable for
walk-over and drive-over
applications.
12.48” (317 mm)
Ø10.33” (262 mm)
IP68 Connector & Junction Box
The luminaire is fitted with an IP68 connector, which attaches directly to the cord supplied
with LS6052-K, without the use of any tools. The cord is 1.8' (0.56 m) in length, and is factory
assembled with a 4 way, ¾" junction box - Remains field serviceable after installation.
Not suitable for color changing or dimmable applications.
Connection Type '84' for LS6052-K-SP
Pre-Installation Blockout
Connection Type '82' for LS6052-K-SP
Pre-Installation Blockout
GripGlass™
OptiClear™ glass with
slip reduction glazing
process. Suitable for
walk-over and drive-over
applications.
Borosilicate Glass
Ideal for limited
access locations. Not
recommended for high
traffic pedestrian areas.
Cover Options for
Pre-Installation Blockout
Flush covers for pre-installation use special
seals and support bushes to ensure static
loads up to 8 140 lb (3 700 kg) are properly
supported. In order to achieve this driveover rating, OptiClear™ or GripGlass™
must be used.
6.5' SOOW Cord
For connection to the branch circuit via
junction box (by others) or other
approved method.
c/w 6.5' SOOW Cord (16/3)
www.lumascape.com
½" NPT Adapter
The luminaire is factory-fitted with 6.5'
hookup wire. Ensure terminations can be
made within this length.
For other length options, consult factory.
Pre-Installation Blockout
Round Flush Cover
■ SS316: Polished
■ SS316: Brushed
C1883US 6 Sep 2013
LS853LED Pre-Installation Blockout
Product
Lamp
Lens
Cover
Ingrade
Connection
Type
Wire
Housing
Entry
Depth Location
Optical
System
LS853LED
29
LAMP
Input
Voltage
Q
OPTICAL SYSTEM
Description Wattage Color
LED
16 W
Code
White
16W4
Warm white
16H6
(4 300 K typ.)
(3 000 K typ.)
Blue
16B4
(470 nm)
LED
20 W
Description Beam
Code
Adjustable
Narrow
14˚
NR (1)
Adjustable
Narrow Medium
25˚
Adjustable
Medium
30˚
Adjustable
Linear Horizontal 40˚ x 20˚
Adjustable
Linear Vertical
NM
ME (2)
LH (3)
LV (3)
20˚ x 40˚
White
20W4
Warm white
20H6
Not available for RGB.
(2)
Recommended for best RGB color mixing.
(3)
Refer to beam orientation diagram.
Blue
(470 nm)
20B4
HOUSING DEPTH
RGB
20M4
Description
(4 300 K typ.)
(3 000 K typ.)
(1)
Code
29
12.48" (317 mm)
LENS
Description
OptiClear™
Code
Very high optical purity
and load strength
A
WIRE ENTRY LOCATION
Description
(1)
Code
Q
Bottom
GripGlass™ OptiClear™ with
slip reduction glazing
process
G (1)
Borosilicate
Glass
X
Ideal for limited access
locations
INPUT VOLTAGE
Description
(2)
Code
120-277 V, 50/60 Hz
(1)
Suitable for drive-over.
(2)
Not suitable for drive-over.
0-10 V Dimmable Driver, 120-277 V, 50/60 Hz
12-15 V, 60 Hz or 12-24 V DC
PWM Dimmable Driver, 12 V, 60 Hz or 12-24 V DC
COVER
Description
Round Flush
Cover
Material
Stainless
steel
Finish
(1)
Code
Polished
Brushed
(2)
(3)
M
N
Not available for RGB.
Not available with 16 W module.
Requires appropriate transformer.
Dimmable Wiring Diagram Reference
Input Voltage
LED Color
Control Type
Wiring Diagram
09-DIM
Single Color
0-10 V
1
13-DIM
Single Color
PWM
6
13-DIM
RGB
PWM
8,9
CONNECTION TYPE
Description
09 (1)
09-DIM(1)(2)
13 (1)(2)(3)
13-DIM (3)
Code
IP68 Connector & Junction Box
85 (1)
6.5' SOOW Cord
84 (2)
½" NPT Adapter
82 (2)
(1)
Not suitable for color changing or dimmable applications.
LS6052-K required - order separately.
(2)
LS6052-K-SP required - order separately.
LS853LED Accessories
Stacking and order of accessories
OR
LS6013
Slatted louver
OR
LS688
Wall wash lens
OR
LS699
Wide angle
wall wash lens
LS6012
Cross hatch louver
OR
LS685
Linear spreader lens
LS691
Prismatic lens
LED
Other accessory stacking options may be available - consult factory
www.lumascape.com
C1883US 6 Sep 2013
LS853LED Direct Burial
Ingrade
Why Use Direct Burial?
Direct burial installation is ideal for landscaping areas or for special applications where depth is restricted. This type of installation also allows for
maximum heat dissipation. The 316 grade Stainless Steel construction of the luminaire performs flawlessly in alkaline and acidic soil types, and is
also rated for use in concrete pour applications. Note: This installation type has no option for a pre-installation blockout.
Lumascape provides the LS853LED complete with 6.5' of factory installed hookup wire and ½" NPT adapter, supplied complete with MicroAntiLeach™
seal. This provides the installer with greater flexibility to determine the nature of the branch circuit connection. This connection is also 100%
hardwired. All aspects of the luminaire itself remain field serviceable.
Consult factory for application advice prior to using this configuration.
Connection type '82' for 'Direct Burial'
housing
Lens Options
OptiClear™ Glass
Glass of very high optical
purity and load strength.
Suitable for walk-over and
drive-over applications.
GripGlass™
OptiClear™ glass with slip
reduction glazing process.
Suitable for walk-over and
drive-over applications.
½" NPT Adapter
Borosilicate Glass
Ideal for limited
access locations. Not
recommended for high
traffic pedestrian areas.
The luminaire is factory-fitted with 6.5'
hookup wire. Ensure terminations can be
made within this length.
For other length options, consult factory.
Cover Options for Direct Burial
Use recessed cover for installation in soil,
grass, pavers and other uneven surfaces
where no cover overhang is desired.
Use flush covers for installation in fine finished surfaces such as granite and
marble. They can also be used in some suspended applications. The flush cover
will conceal gaps between the luminaire and the surrounding surface.
Recessed Cover
Round Flush Cover
Square Flush Cover
■ SS316: Polished
■ SS316: Brushed
■ SS316: Polished
■ SS316: Brushed
■ SS316: Brushed
Ø6.94” (176 mm)
www.lumascape.com
0.98”
(25 mm)
Ø6.94” (176 mm)
Ø
6
76 .94
m ”
m
)
0.12” (3 mm)
(1
Ø10.08” (256 mm)
Ø9.43” (239 mm)
Housing OD
7.09” (180 mm)
0.98”
(25 mm)
0.12” (3 mm)
Ø9.43” (239 mm)
Housing OD
7.09” (180 mm)
Ø
(1 6.
76 94
m ”
m
)
Ø9.43” (239 mm)
Housing OD
7.09” (180 mm)
Ø
(1 6.
76 94
m ”
m
)
Ø10.08” (256 mm)
Cover OD
0.98”
(25 mm)
Ø6.94” (176 mm)
C1883US 6 Sep 2013
LS853LED Direct Burial
Product
Lamp
Lens
Ingrade
Cover
LS853LED
Connection
Type
82
LAMP
16 W
Code
White
16W4
Warm white
16H6
(4 300 K typ.)
(3 000 K typ.)
Blue
(470 nm)
LED
Input
Voltage
28
OPTICAL SYSTEM
Description Wattage Color
LED
Wire
Housing
Entry
Depth Location
Optical
System
20 W
16B4
White
20W4
Warm white
20H6
Blue
(470 nm)
20B4
RGB
20M4
(4 300 K typ.)
(3 000 K typ.)
Description Beam
Code
Adjustable
Narrow
14˚
NR (1)
Adjustable
Narrow Medium
25˚
Adjustable
Medium
30˚
Adjustable
Linear Horizontal 40˚ x 20˚
Adjustable
Linear Vertical
NM
ME (2)
LH (3)
LV (3)
Not available for RGB.
(2)
Recommended for best RGB color mixing.
(3)
Refer to beam orientation diagram.
HOUSING DEPTH
Description
OptiClear™
Code
28
7.09" (180 mm)
LENS
Description
20˚ x 40˚
(1)
WIRE ENTRY LOCATION
Code
Very high optical purity
and load strength
Description
A
Code
N
Q
Side
Bottom
GripGlass™ OptiClear™ with
slip reduction glazing
process
G
Borosilicate
Glass
X
INPUT VOLTAGE
Description
Ideal for limited access
locations
Code
120-277 V, 50/60 Hz
0-10 V Dimmable Driver, 120-277 V, 50/60 Hz
12-15 V, 60 Hz or 12-24 V DC
COVER
Description Material
Finish
Recessed
Cover
Polished
Stainless
steel
Brushed
Round Flush Stainless
Cover
steel
Brushed
Square Flush Stainless
Cover
steel
Polished
Brushed
PWM Dimmable Driver, 12 V, 60 Hz or 12-24 V DC
Code
(1)
Not available for RGB.
Not available with 16 W module.
(3)
Requires appropriate transformer.
B
H
(2)
D
I
Dimmable Wiring Diagram Reference
½" NPT Adapter
Input Voltage
LED Color
Control Type
Wiring Diagram
09-DIM
Single Color
0-10 V
1
13-DIM
Single Color
PWM
6
13-DIM
RGB
PWM
8,9
V
LS853LED Accessories
CONNECTION TYPE
Description
09 (1)
09-DIM(1)(2)
13 (1)(2)(3)
13-DIM (3)
Code
Stacking and order of accessories
82
LS636
Brass grill
External accessory
Use with recessed covers only
Not suitable for use in traffic areas
OR
LS6013
Slatted louver
OR
LS688
Wall wash lens
OR
LS699
Wide angle
wall wash lens
LS6012
Cross hatch louver
OR
LS685
Linear spreader lens
LS691
Prismatic lens
LED
Other accessory stacking options may be available - consult factory
www.lumascape.com
C1883US 6 Sep 2013
LS853LED Photometrics
Ingrade
Photometrics
Photometric data is based on test results from a NIST traceable testing lab. IES data is available at www.lumascape.com.
Note: No depreciation factor is applied to the data shown.
Polar Candela Distribution
LS853LED
(1)
4 300 K
14° Beam Angle
Power Input
17 W
Lumens
959
Efficacy
56 lm/W
(1)
To approximate warm white
data, multiply by 0.84. Refer
web site for IES files for all
color temperatures.
LS853LED
(1)
4 300 K
25° Beam Angle
Power Input
21 W
Lumens
1265
Efficacy
60 lm/W
(1)
To approximate warm white
data, multiply by 0.84. Refer
web site for IES files for all
color temperatures.
170º
10371
Illuminance at a Distance
160º
150º
140º
7778
130º
120º
5186
110º
2593
100º
90º
C-0º
170º
5682
160º
150º
140º
4262
130º
120º
2841
110º
1421
100º
90º
C-0º
LS853LED
(1)
4 300 K
30° Beam Angle
Power Input
21 W
Lumens
1137
Efficacy
54 lm/W
(1)
To approximate warm white
data, multiply by 0.84. Refer
web site for IES files for all
color temperatures.
LS853LED
(1)
4 300 K
20° x 40°
Beam Angle
Power Input
21 W
Lumens
1126
Efficacy
54 lm/W
(1)
To approximate warm white
data, multiply by 0.84. Refer
web site for IES files for all
color temperatures.
170º
3832
160º
150º
140º
2874
130º
120º
1916
110º
958
100º
90º
C-0º
170º
3510
160º
150º
140º
2633
130º
120º
1755
110º
878
100º
C-0º
C-90º
90º
C 0°
C 15° C 30° C 45° C 60° C 75° C 90°
90°
0
0
0
0
0
0
0
100°
0
0
0
0
0
0
0
110°
0
0
0
0
0
0
0
120°
0
0
0
0
0
0
0
130°
2
3
3
4
3
3
2
140°
18
18
18
18
18
17
16
150°
62
63
64
63
61
57
55
160°
322
326
326
319
300
292
290
170°
3080
3084
3070
3039
2984
2938
2912
180°
10371 10371 10371 10371 10371 10371 10371
C 0°
C 15° C 30° C 45° C 60° C 75° C 90°
90°
0
0
0
0
0
0
0
100°
0
0
0
0
0
0
0
110°
0
0
0
0
0
0
0
120°
0
0
0
0
0
0
0
130°
7
5
5
4
4
6
7
140°
23
25
26
25
23
21
150°
155
148
146
144
145
145
160°
1001
987
961
953
961
964
956
170°
3573
3543
3518
3498
3475
3475
3493
180°
5682
5682
5682
5682
5682
5682
5682
C 0°
C 15° C 30° C 45° C 60° C 75° C 90°
90°
0
0
0
0
0
0
0
100°
0
0
0
0
0
0
0
Center Beam fc
Beam Ø
5
414.8
1 ft
10
103.7
3 ft
15
46.1
4 ft
25
16.6
7 ft
30
11.5
8 ft
40
6.5
11 ft
50
4.1
13 ft
Center Beam fc
Beam Ø
5
227.3
2 ft
10
56.8
4 ft
15
25.3
7 ft
22
25
9.1
11 ft
162
30
6.3
13 ft
40
3.6
18 ft
50
2.3
22 ft
Center Beam fc
Beam Ø
110°
0
0
0
0
0
0
0
120°
0
0
0
0
0
0
0
130°
12
11
9
7
8
9
11
140°
43
46
50
52
52
48
43
150°
206
204
204
209
210
209
219
160°
881
874
853
849
865
897
923
170°
2495
2463
2439
2435
2452
2489
2554
180°
3832
3832
3832
3832
3832
3832
3832
C 0°
C 15° C 30° C 45° C 60° C 75° C 90°
90°
0
0
0
0
0
0
0
100°
0
0
0
0
0
0
0
110°
0
0
0
0
0
0
0
120°
0
0
0
0
0
0
0
130°
10
9
8
8
13
21
28
140°
20
21
26
44
82
132
138
150°
89
101
130
199
325
479
541
160°
565
593
697
888
1149
1477
1582
170°
2073
2118
2252
2460
2714
2862
2905
180°
3510
3510
3510
3510
3510
3510
3510
ft
ft
ft
5
153.3
3 ft
10
38.3
5 ft
15
17
8 ft
25
6.1
13 ft
30
4.3
16 ft
40
2.4
21 ft
50
1.5
27 ft
Center
Beam fc
Beam W
Beam L
5
140.4
2 ft
4 ft
10
35.1
4 ft
7 ft
15
15.6
5 ft
11 ft
25
5.6
9 ft
18 ft
30
3.9
11 ft
22 ft
40
2.2
14 ft
29 ft
50
1.4
18 ft
36 ft
ft
Beam Orientations
Beam Orientation
for the "LV" optical
system
www.lumascape.com
Beam Orientation
for the "LH" optical
system
C1883US 6 Sep 2013
Wiring Diagrams
Technical Data
Diagram 1 - 0-10 V Dimming for Line Voltage LED Luminaires
0-10 V
Please note: The use of a GFCI may be required. Consult local wiring rules.
120-277 V
0-10 V +
0-10 V –
0-10 V
wall box
dimmer
OR
Other
0-10 V signal
Diagram 6 - 0-10 V Dimming - Low Voltage LED Luminaire on 12-15 V AC or 24 V DC Circuit
PWM DIM
LS-TWM-1/2/3
120 V
120-277 V
12-15 V AC / 24 V DC
or
LSLED-24V96W277
LSLED-24V12W277
Power Supply
LS6133
0-10 V to PWM
Dimming Signal Converter
(suitable NEMA enclosure required - by others)
0-10 V
wall box
dimmer
PWM +
PWM ï
NOTE: Dimming behavior of these
luminaires is inverted.
0-10 V +
0-10 V ï
OR
Other
0-10 V signal
Use compatibility table to determine
maximum number of luminaires
the power supply can support.
NOTE: The above diagrams are intended to show electrical pathways between luminaires and ancillary devices. These diagrams are not intended to show type or
color of cord/wire, wire gauge or approved use of the cord/wire supplied with luminaires.
Consult the luminaire-specific cutsheet or the factory for detailed specifications.
www.lumascape.com
Wiring Diagrams
Technical Data
Diagram 8 - RGB via DMX for Low Voltage LED Luminaire on 12-15 V AC Circuit
PWM DIM
120 V
120-277 V
LS-TWM-1/2/3
Remote Magnetic
Transformer
12-15 V AC
Com +
Rï
Gï
Bï
LS67100
DMX to PWM
Translator
LSLED-24V96W277
Power Supply
1 unit included with each LS67100
DMX In
DMX Out
Use compatibility table to determine
maximum number of luminaires
the power supply can support.
Diagram 9 - RGB via DMX for Low Voltage LED Luminaire on 24 V DC Circuit
PWM DIM
120-277 V
LSLED-24V96W277
24 V DC +
1 unit included with each LS67100
24 V DC ï
Power Supply
Com +
Rï
Gï
Bï
LS67100
DMX to PWM
Translator
DMX In
DMX Out
Use compatibility table to determine
maximum number of luminaires
the power supply can support.
NOTE: The above diagrams are intended to show electrical pathways between luminaires and ancillary devices. These diagrams are not intended to show type or
color of cord/wire, wire gauge or approved use of the cord/wire supplied with luminaires.
Consult the luminaire-specific cutsheet or the factory for detailed specifications.
www.lumascape.com
Transformers and Power Supply Compatibility
Technical Data
Transformers and Power Supplies for Low Voltage LED Luminaires
The following list of transformers and power supplies are for use with luminaires specifically described as being compatible with either 12 V AC (wirewound only)
transformers or with 12-24 V DC power supplies. Compatibility will be noted in the ordering code of the luminaire concerned, and will typically be referenced by Voltage
Code '13' or '13-DIM'. In the case of '13-DIM' additional components may be required. Refer to the applicable wiring diagram/s.
Compatibility with each transformer or power supply is indicated by the value mentioned, representing the maximum number of luminaires that may be powered
from each transformer or power supply. Please note, this does not take into consideration voltage drop or ampacity limits of the branch circuit. For assistance, please
contact factory.
Wall Mounted Landscape Lighting Transformers
Input Voltage
Output Voltage
Wattage
LS-TWM-1-300
LS-TWM-2-600
LS-TWM-3-900
120 V, 60 Hz
120 V, 60 Hz
120 V, 60 Hz
2 x 300 W circuits
3 x 300 W circuits
8
16
24
LS853LED, 20 Watt
www.lumascape.com
Direct Burial
Transformer
LS-TWM-50 LS-TWM-100 LS-TWM-150 LS-TWM-250 LSLED-24V96W277 LS-TDB1-300
120 V, 60 Hz 120 V, 60 Hz 120 V, 60 Hz
12/13/14/15 V 60 Hz 12/13/14/15 V 60 Hz 12/13/14/15 V 60 Hz 12 V, 60 Hz
1 x 300 W circuit
Class 2 Power
Supply
Wall Mounted Transformers
50 W
120 V, 60 Hz 120-277 V, 50/60 Hz 120 V, 60 Hz
12 V, 60 Hz
12 V, 60 Hz
12 V, 60 Hz
24 V DC
12.5 V, 60 Hz
100 W
150 W
250 W
96 W
300 W
1
Transformer / Power Supply Specifications
Technical Data
Transformers for Landscape Lighting Applications
LS-TWM-1-300
LS-TWM-2-600
Magnetic transformer - wall mounted
Magnetic transformer - wall mounted
Input
Rating
Output
Output Circuits
Protection
Approvals
NEMA Rating
Construction
Dimensions
Weight
Input
Rating
Output
Output Circuits
Protection
Approvals
NEMA Rating
Construction
Dimensions
Weight
120 V
300 W
12/13/14/15 V
1
Electrostatic shield, magnetic breaker
UL, CUL
3R
Stainless steel
H 17.6" (447 mm) W 6.8" (173 mm) D 6.19" (157 mm)
27 lb (12.3 kg)
120 V
600 W
12/13/14/15 V
2
Electrostatic shield, magnetic breaker
UL, CUL
3R
Stainless steel
H 17.6" (447 mm) W 6.8" (173 mm) D 6.19" (157 mm)
29 lb (13.2 kg)
LS-TWM-3-900
LS-TDB1-300
Magnetic transformer - wall mounted
Magnetic transformer - direct burial
Input
Rating
Output
Output Circuits
Protection
Approvals
NEMA Rating
Construction
Dimensions
Weight
Input
Rating
Output
Output Circuits
Protection
Approvals
NEMA Rating
Construction
Dimensions
Weight
120 V
900 W
12/13/14/15 V
3
Electrostatic shield, magnetic breaker
UL, CUL
3R
Stainless steel
H 18.6" (472 mm) W 7.8" (198 mm) D 6.19" (157 mm)
34 lb (15.5 kg)
120 V
300 W
12.5 V
1
Circuit breaker
ETL (US and Canada)
12
Reinforced composite
H 9" (229 mm)
W 9" (229 mm)
8 lb (3.6 kg)
D 7" (178 mm)
Class 2 LED Power Supplies
LSLED-24V96W277
LSLED-24V12W277
Electronic DC power supply - wall mounted
Electronic DC power supply - NEMA enclosure required (by others)
Input
Rating
Output
Output Circuits
Approvals
Location
Dimensions
Weight
Input
Rating
Output
Output Circuits
Approvals
IP rating
Location
Dimensions
Weight
120-277 V, 50/60 Hz
96 W / 4 A
24 V DC
1
CSA, CSA-US
Wet location
H 12.32" (313 mm) W 2.54" (65 mm) D 1.67" (42 mm)
2 lb (0.9 kg)
www.lumascape.com
120-277 V, 50/60 Hz
12 W / 0.5 A
24 V DC
1
UL, CUL Recognized, Class 2
IP66
Wet location
H 3.35" (85 mm)
W 1.42" (36 mm) D 0.91" (23 mm)
0.282 lb (0.1 kg)
Control Specifications
Technical Data
Control Related Equipment
LS6133
LS67100
0-10 V to PWM translator - NEMA enclosure required (by others)
DMX to PWM translator - dry location only
Input
Rating
Output
Output Circuits
Approvals
IP Rating
Dimensions
Weight
Input
Rating
Output
Output Circuits
Approvals
IP Rating
Dimensions
Weight
24 V DC
96 W max
4 A max
1
UL, CUL Recognized, Class 2
IP66
H 5.2" (132 mm)
W 1.3" (33 mm)
0.2 lb (0.1 kg)
www.lumascape.com
D 1" (25 mm)
24 V DC
4 x 60 W max
4 x 2.5 A max
4
UL, CUL
N/A
H 11.25" (286 mm) W 4.6" (117 mm)
0.5 lb (0.2 kg)
D 3.2 (82 mm)
Download