1300 Industrial Road, Unit #19 San Carlos, CA 94070 FREE CALL 1-866-695-5862 US & Canada info@lumascape.com LS853LED Ingrade 0-10 V OPTIONAL OPTIONAL OPTIONAL PWM DIM IP68 IK10 OPTIONAL The LS853LED is a full featured, shallow depth ingrade luminaire featuring lumen output and efficacy exceeding metal halide. As an inherently protected luminaire it can be used in interior spaces and immediately adjacent to combustible materials (such as wood decking, etc). Dimming options include 0-10 V and PWM protocols, with various power input options, including 120-277 V. In addition, internal rotation and tilt adjustability ensures the most efficient light delivery can be set according to site conditions. Specifications Lamp Source 16 W or 20 W LED □ White (4 300 K typical) ■ Warm white (3 000 K typical) ■ Blue (470 nm) Other colors by request RGB Approved Use Lumen Maintenance (L70) Suitable for wet locations Suitable for use in poured concrete Inherently protected LS853LED with round flush cover >60,000 hrs Limited by TM-21 x6 rule 360o Control Options 0-10 V PWM IP Rating IP68 Construction 316 marine grade stainless steel Installation Types Pre-Installation Blockout Concrete pour, drive-over & general use applications 20° 20° Direct Burial Landscapes, planters & special applications (consult factory) Drive-over With OptiClear™ lens and pre-installation blockout (LS6052-K or LS6052-K-SP) Static Load Rating 8 140 lb (3 700 kg) with OptiClear™ lens and preinstallation blockout (LS6052-K or LS6052-K-SP) (Load applied to center of glass across a 2" diameter area) Impact Rating IK10 with OptiClear™ lens Standard Inclusions Teflon coated cover screws MicroAntiLeach™ wire entry Accessories LS6052-K/LS6052-K-SP Pre-installation blockout Remote Transformers / Refer to Technical Data section for application specific options Power Supplies Order separately Ambient Operating Temperature 16 W 20 W -22 °F to 104 °F (-30 °C to +40 °C) -22 °F to 122 °F (-30 °C to +50 °C) Surface Temperature ≤113 °F (45 °C) Photometrics Refer to www.lumascape.com Any luminaire can become hot - take care with appropriate use and placement www.lumascape.com C1883US 6 Sep 2013 LS853LED Pre-Installation Blockout Ingrade Why Use LS6052-K Pre-Installation Blockout? Why Use LS6052-K-SP Pre-Installation Blockout? The LS6052-K acts as a blockout, and is intended for installation before the luminaire, however it has other special functions. To simplify the installation, every LS6052-K is supplied complete with a 4-way, ¾" PVC junction box, inside which the installer can make all necessary connections, and allows the completion of all wiring even before the luminaire arrives on site. This method also ensures the luminaire itself is not damaged during concreting or other site works. Note: The junction box remains serviceable after installation. To complete the installation, Lumascape provides an IP68 connector, enabling a tool-free final connection from the luminaire to the branch circuit. In addition, this connector is readily detachable, allowing for off-site maintenance. The LS6052-K-SP pre-installation kit (order separately) is ideal for use in applications where maximum flexibility for the type and location of branch circuit connections are required or where exact site conditions may be unknown. The LS6052-K-SP is also for use with all applications requiring a color changing or dimmable lighting scheme. For use with the LS6052-K-SP, Lumascape provides the LS853LED complete with 6.5' of factory-installed hookup wire or an SOOW cord (both options include a MicroAntiLeach™ seal). This provides the installer with greater flexibility to determine the type and location of the branch circuit connection. This option is also 100% hard-wired, and does not feature the IP68 detachable couplings for off-site maintenance. All aspects of the luminaire itself are still field serviceable. Connection Type '85' for LS6052-K Pre-Installation Blockout Lens Options 94 6. m m (1 76 Ø ) ” OptiClear™ Glass Glass of very high optical purity and load strength. Suitable for walk-over and drive-over applications. 12.48” (317 mm) Ø10.33” (262 mm) IP68 Connector & Junction Box The luminaire is fitted with an IP68 connector, which attaches directly to the cord supplied with LS6052-K, without the use of any tools. The cord is 1.8' (0.56 m) in length, and is factory assembled with a 4 way, ¾" junction box - Remains field serviceable after installation. Not suitable for color changing or dimmable applications. Connection Type '84' for LS6052-K-SP Pre-Installation Blockout Connection Type '82' for LS6052-K-SP Pre-Installation Blockout GripGlass™ OptiClear™ glass with slip reduction glazing process. Suitable for walk-over and drive-over applications. Borosilicate Glass Ideal for limited access locations. Not recommended for high traffic pedestrian areas. Cover Options for Pre-Installation Blockout Flush covers for pre-installation use special seals and support bushes to ensure static loads up to 8 140 lb (3 700 kg) are properly supported. In order to achieve this driveover rating, OptiClear™ or GripGlass™ must be used. 6.5' SOOW Cord For connection to the branch circuit via junction box (by others) or other approved method. c/w 6.5' SOOW Cord (16/3) www.lumascape.com ½" NPT Adapter The luminaire is factory-fitted with 6.5' hookup wire. Ensure terminations can be made within this length. For other length options, consult factory. Pre-Installation Blockout Round Flush Cover ■ SS316: Polished ■ SS316: Brushed C1883US 6 Sep 2013 LS853LED Pre-Installation Blockout Product Lamp Lens Cover Ingrade Connection Type Wire Housing Entry Depth Location Optical System LS853LED 29 LAMP Input Voltage Q OPTICAL SYSTEM Description Wattage Color LED 16 W Code White 16W4 Warm white 16H6 (4 300 K typ.) (3 000 K typ.) Blue 16B4 (470 nm) LED 20 W Description Beam Code Adjustable Narrow 14˚ NR (1) Adjustable Narrow Medium 25˚ Adjustable Medium 30˚ Adjustable Linear Horizontal 40˚ x 20˚ Adjustable Linear Vertical NM ME (2) LH (3) LV (3) 20˚ x 40˚ White 20W4 Warm white 20H6 Not available for RGB. (2) Recommended for best RGB color mixing. (3) Refer to beam orientation diagram. Blue (470 nm) 20B4 HOUSING DEPTH RGB 20M4 Description (4 300 K typ.) (3 000 K typ.) (1) Code 29 12.48" (317 mm) LENS Description OptiClear™ Code Very high optical purity and load strength A WIRE ENTRY LOCATION Description (1) Code Q Bottom GripGlass™ OptiClear™ with slip reduction glazing process G (1) Borosilicate Glass X Ideal for limited access locations INPUT VOLTAGE Description (2) Code 120-277 V, 50/60 Hz (1) Suitable for drive-over. (2) Not suitable for drive-over. 0-10 V Dimmable Driver, 120-277 V, 50/60 Hz 12-15 V, 60 Hz or 12-24 V DC PWM Dimmable Driver, 12 V, 60 Hz or 12-24 V DC COVER Description Round Flush Cover Material Stainless steel Finish (1) Code Polished Brushed (2) (3) M N Not available for RGB. Not available with 16 W module. Requires appropriate transformer. Dimmable Wiring Diagram Reference Input Voltage LED Color Control Type Wiring Diagram 09-DIM Single Color 0-10 V 1 13-DIM Single Color PWM 6 13-DIM RGB PWM 8,9 CONNECTION TYPE Description 09 (1) 09-DIM(1)(2) 13 (1)(2)(3) 13-DIM (3) Code IP68 Connector & Junction Box 85 (1) 6.5' SOOW Cord 84 (2) ½" NPT Adapter 82 (2) (1) Not suitable for color changing or dimmable applications. LS6052-K required - order separately. (2) LS6052-K-SP required - order separately. LS853LED Accessories Stacking and order of accessories OR LS6013 Slatted louver OR LS688 Wall wash lens OR LS699 Wide angle wall wash lens LS6012 Cross hatch louver OR LS685 Linear spreader lens LS691 Prismatic lens LED Other accessory stacking options may be available - consult factory www.lumascape.com C1883US 6 Sep 2013 LS853LED Direct Burial Ingrade Why Use Direct Burial? Direct burial installation is ideal for landscaping areas or for special applications where depth is restricted. This type of installation also allows for maximum heat dissipation. The 316 grade Stainless Steel construction of the luminaire performs flawlessly in alkaline and acidic soil types, and is also rated for use in concrete pour applications. Note: This installation type has no option for a pre-installation blockout. Lumascape provides the LS853LED complete with 6.5' of factory installed hookup wire and ½" NPT adapter, supplied complete with MicroAntiLeach™ seal. This provides the installer with greater flexibility to determine the nature of the branch circuit connection. This connection is also 100% hardwired. All aspects of the luminaire itself remain field serviceable. Consult factory for application advice prior to using this configuration. Connection type '82' for 'Direct Burial' housing Lens Options OptiClear™ Glass Glass of very high optical purity and load strength. Suitable for walk-over and drive-over applications. GripGlass™ OptiClear™ glass with slip reduction glazing process. Suitable for walk-over and drive-over applications. ½" NPT Adapter Borosilicate Glass Ideal for limited access locations. Not recommended for high traffic pedestrian areas. The luminaire is factory-fitted with 6.5' hookup wire. Ensure terminations can be made within this length. For other length options, consult factory. Cover Options for Direct Burial Use recessed cover for installation in soil, grass, pavers and other uneven surfaces where no cover overhang is desired. Use flush covers for installation in fine finished surfaces such as granite and marble. They can also be used in some suspended applications. The flush cover will conceal gaps between the luminaire and the surrounding surface. Recessed Cover Round Flush Cover Square Flush Cover ■ SS316: Polished ■ SS316: Brushed ■ SS316: Polished ■ SS316: Brushed ■ SS316: Brushed Ø6.94” (176 mm) www.lumascape.com 0.98” (25 mm) Ø6.94” (176 mm) Ø 6 76 .94 m ” m ) 0.12” (3 mm) (1 Ø10.08” (256 mm) Ø9.43” (239 mm) Housing OD 7.09” (180 mm) 0.98” (25 mm) 0.12” (3 mm) Ø9.43” (239 mm) Housing OD 7.09” (180 mm) Ø (1 6. 76 94 m ” m ) Ø9.43” (239 mm) Housing OD 7.09” (180 mm) Ø (1 6. 76 94 m ” m ) Ø10.08” (256 mm) Cover OD 0.98” (25 mm) Ø6.94” (176 mm) C1883US 6 Sep 2013 LS853LED Direct Burial Product Lamp Lens Ingrade Cover LS853LED Connection Type 82 LAMP 16 W Code White 16W4 Warm white 16H6 (4 300 K typ.) (3 000 K typ.) Blue (470 nm) LED Input Voltage 28 OPTICAL SYSTEM Description Wattage Color LED Wire Housing Entry Depth Location Optical System 20 W 16B4 White 20W4 Warm white 20H6 Blue (470 nm) 20B4 RGB 20M4 (4 300 K typ.) (3 000 K typ.) Description Beam Code Adjustable Narrow 14˚ NR (1) Adjustable Narrow Medium 25˚ Adjustable Medium 30˚ Adjustable Linear Horizontal 40˚ x 20˚ Adjustable Linear Vertical NM ME (2) LH (3) LV (3) Not available for RGB. (2) Recommended for best RGB color mixing. (3) Refer to beam orientation diagram. HOUSING DEPTH Description OptiClear™ Code 28 7.09" (180 mm) LENS Description 20˚ x 40˚ (1) WIRE ENTRY LOCATION Code Very high optical purity and load strength Description A Code N Q Side Bottom GripGlass™ OptiClear™ with slip reduction glazing process G Borosilicate Glass X INPUT VOLTAGE Description Ideal for limited access locations Code 120-277 V, 50/60 Hz 0-10 V Dimmable Driver, 120-277 V, 50/60 Hz 12-15 V, 60 Hz or 12-24 V DC COVER Description Material Finish Recessed Cover Polished Stainless steel Brushed Round Flush Stainless Cover steel Brushed Square Flush Stainless Cover steel Polished Brushed PWM Dimmable Driver, 12 V, 60 Hz or 12-24 V DC Code (1) Not available for RGB. Not available with 16 W module. (3) Requires appropriate transformer. B H (2) D I Dimmable Wiring Diagram Reference ½" NPT Adapter Input Voltage LED Color Control Type Wiring Diagram 09-DIM Single Color 0-10 V 1 13-DIM Single Color PWM 6 13-DIM RGB PWM 8,9 V LS853LED Accessories CONNECTION TYPE Description 09 (1) 09-DIM(1)(2) 13 (1)(2)(3) 13-DIM (3) Code Stacking and order of accessories 82 LS636 Brass grill External accessory Use with recessed covers only Not suitable for use in traffic areas OR LS6013 Slatted louver OR LS688 Wall wash lens OR LS699 Wide angle wall wash lens LS6012 Cross hatch louver OR LS685 Linear spreader lens LS691 Prismatic lens LED Other accessory stacking options may be available - consult factory www.lumascape.com C1883US 6 Sep 2013 LS853LED Photometrics Ingrade Photometrics Photometric data is based on test results from a NIST traceable testing lab. IES data is available at www.lumascape.com. Note: No depreciation factor is applied to the data shown. Polar Candela Distribution LS853LED (1) 4 300 K 14° Beam Angle Power Input 17 W Lumens 959 Efficacy 56 lm/W (1) To approximate warm white data, multiply by 0.84. Refer web site for IES files for all color temperatures. LS853LED (1) 4 300 K 25° Beam Angle Power Input 21 W Lumens 1265 Efficacy 60 lm/W (1) To approximate warm white data, multiply by 0.84. Refer web site for IES files for all color temperatures. 170º 10371 Illuminance at a Distance 160º 150º 140º 7778 130º 120º 5186 110º 2593 100º 90º C-0º 170º 5682 160º 150º 140º 4262 130º 120º 2841 110º 1421 100º 90º C-0º LS853LED (1) 4 300 K 30° Beam Angle Power Input 21 W Lumens 1137 Efficacy 54 lm/W (1) To approximate warm white data, multiply by 0.84. Refer web site for IES files for all color temperatures. LS853LED (1) 4 300 K 20° x 40° Beam Angle Power Input 21 W Lumens 1126 Efficacy 54 lm/W (1) To approximate warm white data, multiply by 0.84. Refer web site for IES files for all color temperatures. 170º 3832 160º 150º 140º 2874 130º 120º 1916 110º 958 100º 90º C-0º 170º 3510 160º 150º 140º 2633 130º 120º 1755 110º 878 100º C-0º C-90º 90º C 0° C 15° C 30° C 45° C 60° C 75° C 90° 90° 0 0 0 0 0 0 0 100° 0 0 0 0 0 0 0 110° 0 0 0 0 0 0 0 120° 0 0 0 0 0 0 0 130° 2 3 3 4 3 3 2 140° 18 18 18 18 18 17 16 150° 62 63 64 63 61 57 55 160° 322 326 326 319 300 292 290 170° 3080 3084 3070 3039 2984 2938 2912 180° 10371 10371 10371 10371 10371 10371 10371 C 0° C 15° C 30° C 45° C 60° C 75° C 90° 90° 0 0 0 0 0 0 0 100° 0 0 0 0 0 0 0 110° 0 0 0 0 0 0 0 120° 0 0 0 0 0 0 0 130° 7 5 5 4 4 6 7 140° 23 25 26 25 23 21 150° 155 148 146 144 145 145 160° 1001 987 961 953 961 964 956 170° 3573 3543 3518 3498 3475 3475 3493 180° 5682 5682 5682 5682 5682 5682 5682 C 0° C 15° C 30° C 45° C 60° C 75° C 90° 90° 0 0 0 0 0 0 0 100° 0 0 0 0 0 0 0 Center Beam fc Beam Ø 5 414.8 1 ft 10 103.7 3 ft 15 46.1 4 ft 25 16.6 7 ft 30 11.5 8 ft 40 6.5 11 ft 50 4.1 13 ft Center Beam fc Beam Ø 5 227.3 2 ft 10 56.8 4 ft 15 25.3 7 ft 22 25 9.1 11 ft 162 30 6.3 13 ft 40 3.6 18 ft 50 2.3 22 ft Center Beam fc Beam Ø 110° 0 0 0 0 0 0 0 120° 0 0 0 0 0 0 0 130° 12 11 9 7 8 9 11 140° 43 46 50 52 52 48 43 150° 206 204 204 209 210 209 219 160° 881 874 853 849 865 897 923 170° 2495 2463 2439 2435 2452 2489 2554 180° 3832 3832 3832 3832 3832 3832 3832 C 0° C 15° C 30° C 45° C 60° C 75° C 90° 90° 0 0 0 0 0 0 0 100° 0 0 0 0 0 0 0 110° 0 0 0 0 0 0 0 120° 0 0 0 0 0 0 0 130° 10 9 8 8 13 21 28 140° 20 21 26 44 82 132 138 150° 89 101 130 199 325 479 541 160° 565 593 697 888 1149 1477 1582 170° 2073 2118 2252 2460 2714 2862 2905 180° 3510 3510 3510 3510 3510 3510 3510 ft ft ft 5 153.3 3 ft 10 38.3 5 ft 15 17 8 ft 25 6.1 13 ft 30 4.3 16 ft 40 2.4 21 ft 50 1.5 27 ft Center Beam fc Beam W Beam L 5 140.4 2 ft 4 ft 10 35.1 4 ft 7 ft 15 15.6 5 ft 11 ft 25 5.6 9 ft 18 ft 30 3.9 11 ft 22 ft 40 2.2 14 ft 29 ft 50 1.4 18 ft 36 ft ft Beam Orientations Beam Orientation for the "LV" optical system www.lumascape.com Beam Orientation for the "LH" optical system C1883US 6 Sep 2013 Wiring Diagrams Technical Data Diagram 1 - 0-10 V Dimming for Line Voltage LED Luminaires 0-10 V Please note: The use of a GFCI may be required. Consult local wiring rules. 120-277 V 0-10 V + 0-10 V – 0-10 V wall box dimmer OR Other 0-10 V signal Diagram 6 - 0-10 V Dimming - Low Voltage LED Luminaire on 12-15 V AC or 24 V DC Circuit PWM DIM LS-TWM-1/2/3 120 V 120-277 V 12-15 V AC / 24 V DC or LSLED-24V96W277 LSLED-24V12W277 Power Supply LS6133 0-10 V to PWM Dimming Signal Converter (suitable NEMA enclosure required - by others) 0-10 V wall box dimmer PWM + PWM ï NOTE: Dimming behavior of these luminaires is inverted. 0-10 V + 0-10 V ï OR Other 0-10 V signal Use compatibility table to determine maximum number of luminaires the power supply can support. NOTE: The above diagrams are intended to show electrical pathways between luminaires and ancillary devices. These diagrams are not intended to show type or color of cord/wire, wire gauge or approved use of the cord/wire supplied with luminaires. Consult the luminaire-specific cutsheet or the factory for detailed specifications. www.lumascape.com Wiring Diagrams Technical Data Diagram 8 - RGB via DMX for Low Voltage LED Luminaire on 12-15 V AC Circuit PWM DIM 120 V 120-277 V LS-TWM-1/2/3 Remote Magnetic Transformer 12-15 V AC Com + Rï Gï Bï LS67100 DMX to PWM Translator LSLED-24V96W277 Power Supply 1 unit included with each LS67100 DMX In DMX Out Use compatibility table to determine maximum number of luminaires the power supply can support. Diagram 9 - RGB via DMX for Low Voltage LED Luminaire on 24 V DC Circuit PWM DIM 120-277 V LSLED-24V96W277 24 V DC + 1 unit included with each LS67100 24 V DC ï Power Supply Com + Rï Gï Bï LS67100 DMX to PWM Translator DMX In DMX Out Use compatibility table to determine maximum number of luminaires the power supply can support. NOTE: The above diagrams are intended to show electrical pathways between luminaires and ancillary devices. These diagrams are not intended to show type or color of cord/wire, wire gauge or approved use of the cord/wire supplied with luminaires. Consult the luminaire-specific cutsheet or the factory for detailed specifications. www.lumascape.com Transformers and Power Supply Compatibility Technical Data Transformers and Power Supplies for Low Voltage LED Luminaires The following list of transformers and power supplies are for use with luminaires specifically described as being compatible with either 12 V AC (wirewound only) transformers or with 12-24 V DC power supplies. Compatibility will be noted in the ordering code of the luminaire concerned, and will typically be referenced by Voltage Code '13' or '13-DIM'. In the case of '13-DIM' additional components may be required. Refer to the applicable wiring diagram/s. Compatibility with each transformer or power supply is indicated by the value mentioned, representing the maximum number of luminaires that may be powered from each transformer or power supply. Please note, this does not take into consideration voltage drop or ampacity limits of the branch circuit. For assistance, please contact factory. Wall Mounted Landscape Lighting Transformers Input Voltage Output Voltage Wattage LS-TWM-1-300 LS-TWM-2-600 LS-TWM-3-900 120 V, 60 Hz 120 V, 60 Hz 120 V, 60 Hz 2 x 300 W circuits 3 x 300 W circuits 8 16 24 LS853LED, 20 Watt www.lumascape.com Direct Burial Transformer LS-TWM-50 LS-TWM-100 LS-TWM-150 LS-TWM-250 LSLED-24V96W277 LS-TDB1-300 120 V, 60 Hz 120 V, 60 Hz 120 V, 60 Hz 12/13/14/15 V 60 Hz 12/13/14/15 V 60 Hz 12/13/14/15 V 60 Hz 12 V, 60 Hz 1 x 300 W circuit Class 2 Power Supply Wall Mounted Transformers 50 W 120 V, 60 Hz 120-277 V, 50/60 Hz 120 V, 60 Hz 12 V, 60 Hz 12 V, 60 Hz 12 V, 60 Hz 24 V DC 12.5 V, 60 Hz 100 W 150 W 250 W 96 W 300 W 1 Transformer / Power Supply Specifications Technical Data Transformers for Landscape Lighting Applications LS-TWM-1-300 LS-TWM-2-600 Magnetic transformer - wall mounted Magnetic transformer - wall mounted Input Rating Output Output Circuits Protection Approvals NEMA Rating Construction Dimensions Weight Input Rating Output Output Circuits Protection Approvals NEMA Rating Construction Dimensions Weight 120 V 300 W 12/13/14/15 V 1 Electrostatic shield, magnetic breaker UL, CUL 3R Stainless steel H 17.6" (447 mm) W 6.8" (173 mm) D 6.19" (157 mm) 27 lb (12.3 kg) 120 V 600 W 12/13/14/15 V 2 Electrostatic shield, magnetic breaker UL, CUL 3R Stainless steel H 17.6" (447 mm) W 6.8" (173 mm) D 6.19" (157 mm) 29 lb (13.2 kg) LS-TWM-3-900 LS-TDB1-300 Magnetic transformer - wall mounted Magnetic transformer - direct burial Input Rating Output Output Circuits Protection Approvals NEMA Rating Construction Dimensions Weight Input Rating Output Output Circuits Protection Approvals NEMA Rating Construction Dimensions Weight 120 V 900 W 12/13/14/15 V 3 Electrostatic shield, magnetic breaker UL, CUL 3R Stainless steel H 18.6" (472 mm) W 7.8" (198 mm) D 6.19" (157 mm) 34 lb (15.5 kg) 120 V 300 W 12.5 V 1 Circuit breaker ETL (US and Canada) 12 Reinforced composite H 9" (229 mm) W 9" (229 mm) 8 lb (3.6 kg) D 7" (178 mm) Class 2 LED Power Supplies LSLED-24V96W277 LSLED-24V12W277 Electronic DC power supply - wall mounted Electronic DC power supply - NEMA enclosure required (by others) Input Rating Output Output Circuits Approvals Location Dimensions Weight Input Rating Output Output Circuits Approvals IP rating Location Dimensions Weight 120-277 V, 50/60 Hz 96 W / 4 A 24 V DC 1 CSA, CSA-US Wet location H 12.32" (313 mm) W 2.54" (65 mm) D 1.67" (42 mm) 2 lb (0.9 kg) www.lumascape.com 120-277 V, 50/60 Hz 12 W / 0.5 A 24 V DC 1 UL, CUL Recognized, Class 2 IP66 Wet location H 3.35" (85 mm) W 1.42" (36 mm) D 0.91" (23 mm) 0.282 lb (0.1 kg) Control Specifications Technical Data Control Related Equipment LS6133 LS67100 0-10 V to PWM translator - NEMA enclosure required (by others) DMX to PWM translator - dry location only Input Rating Output Output Circuits Approvals IP Rating Dimensions Weight Input Rating Output Output Circuits Approvals IP Rating Dimensions Weight 24 V DC 96 W max 4 A max 1 UL, CUL Recognized, Class 2 IP66 H 5.2" (132 mm) W 1.3" (33 mm) 0.2 lb (0.1 kg) www.lumascape.com D 1" (25 mm) 24 V DC 4 x 60 W max 4 x 2.5 A max 4 UL, CUL N/A H 11.25" (286 mm) W 4.6" (117 mm) 0.5 lb (0.2 kg) D 3.2 (82 mm)