Megger Cable Fault Location PFL40 series 1 Megger’s new PFL40-1500/2000 Power Fault Locator. Fault Identification LV Pre-Location Fault Diagnosis HV Pre-Location Fault Located Pinpoint Fault Location Fault Located Fault Located Fault Conditioning PFL40 = Restoration 2 Megger’s new PFL40-1500/2000 Power Fault Locator. The PFL40-1500/2000 really is the “Complete Solution” 3 Megger’s new PFL40-1500/2000 Power Fault Locator. • • • • • • • • • What we “offer” Ease of use 9 Cable and fault diagnosis Fault conditioning Fault prelocation Pinpoint fault location 9 Easy to deploy Rapid , accurate and safe Tough, field proven equipment Fully integrated system 9 9 9 9 9 9 9 The PFL40-1500/2000 ticks all the boxes 4 Megger’s new PFL40-1500/2000 Power Fault Locator. What we “offer” • • • • • • • • • • • • Fully integrated system Auto ranging, colour display TDR. d.c. testing up to 40kV Leakage current 25mA constant test current Proof/burn up to 34kV 34kV arc reflection method Impulse Current Voltage Decay (optional) 34kV 3-range surge generator (4kV option) 1500joule (optional 2000j) Safety ground monitor (optional) 5 Megger’s new PFL40-1500/2000 Power Fault Locator. No Spec’s but lets look at the FEATURES, BENEFITS and ADVANTAGES F. The PFL series are portable, stand-alone CFL & HV system. All CFL & HV testing features in one field proven case B. No need to invest in expensive customized test vans A. No other manufacturer has the same feature set in one enclosure/case F. Analogue metering of the voltage and current B Analogue metering is preferred as fault breakdown, and ticking faults can be easily identified A. Analogue metering assists in identifying and diagnosis the type of fault, essential when deciding which fault location method to use. 6 Megger’s new PFL40-1500/2000 Power Fault Locator. No Spec’s but lets look at the FEATURES, BENEFITS and ADVANTAGES F. Easy to use PLC control., selects testing methods B. Selection of HV operations is via this easy to use PLC control. A. There has been a trend in recent years to combine all controls with the TDR. This creates confusion and a difficult to use instrument F. 40kV dc testing & 34kV dc proof / burn features. B. This combination allows d.c. testing (diagnosis) and high voltage fault conditioning. A. No other manufacturer offer both these features in the same unit, they normally offer one or the other. d.c. testing is used for diagnosis & the proof/burn mode is used to stabilise difficult to find faults. 7 Megger’s new PFL40-1500/2000 Power Fault Locator. No Spec’s but lets look at the FEATURES, BENEFITS and ADVANTAGES F. 34kV Surge Voltage B. The 34kV Surge allows the prelocation and pinpoint location of more difficult faults easier. A. This a unique feature that no other manufacturer has in a mobile portable unit. F. 1500 standard and 2000 joule Surge Energy on all ranges. B. The high surge energy enables the creation of a flashover at the point of fault, in difficult situation. A. No other manufacturer offers a 3-range 2000joule surge capability in a single portable unit. 8 Megger’s new PFL40-1500/2000 Power Fault Locator. No Spec’s but lets look at the FEATURES, BENEFITS and ADVANTAGES F. Integrated large colour display TDR. B. The large colour display, makes fault analysis easier, and encompasses pulse echo, arc reflection and impulse current methods of fault prelocation.. A. The large, uncluttered graphical display enables quick and accurate fault location. On-board memory for trace (with parameters) storage and recall, report generation assists with asset management. 9 Megger’s new PFL40-1500/2000 Power Fault Locator. No Spec’s but lets look at the FEATURES, BENEFITS and ADVANTAGES F. Developed, manufactured by Megger. B. Megger has over 100 years of experience of supplying test and measurement equipment worldwide. Several CFL patents are also held dating back sever decades. A. The customer can be assured that he is supported by an International Company, with extensive experience and an experienced world-wide network of distributors and authorised repair agents. 10 Megger’s new PFL40-1500/2000 Power Fault Locator. No Spec’s but lets look at the FEATURES, BENEFITS and ADVANTAGES Patents from the same stable. 1957: Bechtel: Fault Location in Electrical Cables 1974: Ironside: Multiple Null Bridges 1992: Steiner: DART (Differential Arc Reflection Techniques We are Strong ! 11 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) SebaKMT: Trading company of Seba Dynatronic & Hagenuk KMT SFX 40-25 Specification d.c. Testing Current trips Surge -Optional Energy Optional Surge Rate Modes --Proof/Burn SFX 40-25 40kV @ 15mA NO 12.5kV -25kV or 16kv – 32kV 4kV or 8kV 1000joules 2000j (2nd box) 5 – 20 secs ARM Impulse Current Voltage Decay 20kV @ 100mA PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 12 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) SebaKMT: Trading company of Seba Dynatronic & Hagenuk KMT SFX32 Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn SFX 32 32kV @ 15mA NO 8-16-32kV -1000joules 1750j 3 - 10 secs Arc Reflection Impulse Current Voltage Decay 32kV @ 160mA PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 13 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) SebaKMT: Trading company of Seba Dynatronic & Hagenuk KMT SFX 25 Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn SFX 25 25kV @ 5mA NO 12.5 - 25kV -1120joules -3 - 9 secs Arc Reflection ---- PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 14 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) BAUR Can be configured with SSG1100/1500/2100 Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn Syscompact 3000 32kV (850mA max?) NO 8 – 16 – 32kV 1100–1500–2100j 10 – 30secs SIM DC SIM / MIM Impulse Current 32kV (850mA max?) PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 15 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) BAUR Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn Syscompact 2000 16kV @ NO 8 – 16kV 1024joules 10 – 20secs SIM Impulse Current --- PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 16 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) Hiptronics Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn 5100-FC 15kV NO 7.5 or 15kV -480joules -6 secs ARC Reflection ---- PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 17 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) Hipotronics Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn CF 70 Series 70kV NO 25kV -3750joules 7500joules 3 – 30seconds TDR only --70kV @ 100mA PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 18 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) VON Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn XF16-1280 16kV NO 8 – 16kV -1280joules 2560joules 15 secs Arc Reflection ---- PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 19 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) VON Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes --Proof/Burn XF25-1563 25kV NO 12-5 – 25kV -1563joules 3126 joules 15 secs Arc Reflection ---- PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 20 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) VON Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes ---Proof/Burn XF28-1960 28kV NO 14 – 28kV -1960joules 3920joules 15 secs Arc Reflection ----- PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 21 Megger’s new PFL40-1500/2000 Power Fault Locator. Competitor (Other Manufacturers!) VON 2-piece Specification d.c. Testing Current trips Surge Optional Energy Optional Surge Rate Modes ---Proof/Burn XF32-5120 32kV NO 8 – 16 – 32kV -5120joules -15 secs Arc Reflection ----- PFL40-1500/2000 40kV @ 25mA Selectable 8 – 16 – 34kV 4kV 1500joules 2000j (integrated) 2 – 10sec Arc Reflection Impulse Current Voltage Decay 14kV @ 120mA 34kV @ 60mA 22