SOME OF THESE SYMBOLS SHOWN MAY NOT BE USED ON THIS PROJECT V DOWNLIGHT/INDUSTRIAL FIXTURE, SURFACE OR PENDANT MOUNTED. DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, WALL MOUNTED, +18" UON. SINGLE DIRECTIONAL, WALLWASH LIGHT FIXTURE, RECESSED IN CEILING. DENOTES WALL MOUNTED OVER COUNTER, 6" ABOVE BACK SPLASH UON. DUAL DIRECTIONAL, WALLWASH LIGHT FIXTURE, RECESSED IN CEILING. INDOOR FAN POWERED VAV BOX MOTOR, SINGLE PHASE, MOUNTED FROM STRUCTURE ABOVE, NIEC. MAKE POWER CONNECTIONS TO INCLUDE JUNCTION BOX MOUNTED MANUAL MOTOR STARTER AND DISCONNECT ADJACENT TO VAV BOX WITH 2 #12 CONDUCTORS PLUS GROUND IN 1/2" FLEXIBLE CONDUIT BETWEEN STARTER AND MOTOR. 'G' DENOTES GROUND FAULT CURRENT INTERRUPTER (GFCI), 'A' DENOTES ARC FAULT CURRENT INTERRUPTER (AFCI). SINGLE DIRECTIONAL, WALLWASH LIGHT FIXTURE, SURFACE OR PENDANT MOUNTED. AF A PULLBOX OR HANDHOLE, SIZE AND TYPE AS NOTED ON PLANS. SHADING DENOTES DEVICE CONNECTED TO EMERGENCY POWER CIRCUIT. SAFETY DISCONNECT SWITCH, 3 POLE, UON. ADJACENT NUMBER INDICATES FUSE SIZE WHEN APPLICABLE. LABELING CONVENTION AS FOLLOWS: A: 30A, NON-FUSED AF: 30A, FUSED B: 60A, NON-FUSED BF: 60A, FUSED C: 100A, NON-FUSED CF: 100A, FUSED D: 200A, NON-FUSED DF: 200A, FUSED E: 400A, NON-FUSED EF: 400A, FUSED F: 600A, NON-FUSED FF: 600A, FUSED G: 800A, NON-FUSED GF: 800A, FUSED SHADING DENOTES DEVICE WITH ISOLATED GROUND. 1 MAGNETIC MOTOR STARTER. ADJACENT NUMBER INDICATES NEMA SIZE OF STARTER. 1 COMBINATION MAGNETIC MOTOR STARTER/SAFETY DISCONNECT SWITCH. ADJACENT NUMBER INDICATES NEMA SIZE OF STARTER. DUAL DIRECTIONAL, WALLWASH LIGHT FIXTURE, SURFACE OR PENDANT MOUNTED. SHADING DENOTES SPLIT WIRED DEVICE. T VFD VARIABLE FREQUENCY DRIVE WITH INTEGRAL DISCONNECT FURNISHED AND INSTALLED UNDER ANOTHER DIVISION. PROVIDE POWER SERVICE CONNECTION UNDER THIS DIVISION AS NOTED ON PLANS. SHADING DENOTES SPECIALTY DEVICE, TYPE AS NOTED ON PLANS. LINEAR WALLWASH LIGHT FIXTURE, SURFACE OR PENDANT MOUNTED. LINEAR, MULTI-HEAD, ADJUSTABLE ACCENT LIGHT FIXTURES, RECESSED IN CEILING. DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FLUSH FLOOR BOX. SCONCE LIGHT FIXTURE, WALL MOUNTED. DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FIRE-RATED POKE-THRU FLOOR FITTING. DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FIRE-RATED POKE-THRU FLOOR FITTING. T J DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED ON CONDUIT STANCHION FLOOR PENETRATION, +12" UON. P T P S T S FLOODLIGHT FIXTURE, STANCHION MOUNTED ABOVE GRADE. SINGLE-POLE, TIMER CONTROLLED SWITCH, WALL MOUNTED, +42" UON. SM CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING. FLEXIBLE METALLIC CONDUIT. LIGHTING CONTROL OCCUPANCY SENSOR WITH SINGLE LEVEL SWITCHING, WALL MOUNTED, +42" UON. M LIGHTING CONTROL OCCUPANCY SENSOR, CEILING MOUNTED FOR AREA COVERAGE. D PRESET SCENE CONTROL LIGHTING STATION WITH DIMMING CAPABILITIES, WALL MOUNTED, +42" UON. REFER TO PLANS AND SCHEDULES FOR CONTROL. CONDUIT TURNED DOWN. EGRESS LIGHTING TRANSFER DEVICE PC PHOTOELECTRIC CELL DS DAYLIGHT SENSOR, SUBSCRIPTS ARE SWITCH LEGS CONTROLLED a,b BID ALTERNATES BATTERIES. NEUTRAL SERVICE DISCONNECT LINK. NO. C:\Users\jleite\Documents\Center St_jleite.rvt 3/25/2015 7:59:25 AM Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E0.1 SYMBOLS LIST AND DRAWING INDEX.DWG Last Plotted: 2016-04-01 Last saved by: PAUL(2016-03-23) DIGITAL METERING UNIT. WHM WATT HOUR METER. GND GROUND BUS. NEU NEUTRAL BUS. BELOW FINISHED CEILING NC NORMALLY CLOSED BOC BACK OF CURB NF NON-FUSED BPS BOLTED PRESSURE CONTACT SWITCH NIEC NOT IN ELECTRICAL CONTRACT C CONDUIT NO NORMALLY OPEN CCTV CLOSED CIRCUIT TELEVISION NTS NOT TO SCALE CL CURRENT LIMITING CIRCUIT BREAKER OR FUSE OC ON CENTER OFCI CP CIRCULATION PUMP OWNER FURNISHED CONTRACTOR INSTALLED CKT CIRCUIT PDU POWER DISTRIBUTION UNIT CT CURRENT TRANSFORMER PIV POST INDICATING VALVE CU COPPER PNL PANEL DF DRINKING FOUNTAIN PT POTENTIAL TRANSFORMER DW DISH WASHER PVC POLYVINYL CHLORIDE (E) EXISTING TO REMAIN RF REFRIGERATOR EC ELECTRICAL CONTRACTOR (R) EXISTING TO BE REMOVED EF EXHAUST FAN (RL) RELOCATED EP EXPLOSION PROOF (RR) REMOVE AND RELOCATE EPO EMERGENCY POWER OFF RSC RIGID STEEL CONDUIT EMCS ENERGY MANAGEMENT CONTROL SYSTEM SAD SEE ARCHITECTURAL DRAWINGS SPD SURGE PROTECTION DEVICE EMT ELECTRICAL METALLIC TUBING TC TIME CLOCK ETD EMERGENCY TRANSFER DEVICE TGB TELECOMMUNICATIONS GROUND BUS EVCS ELECTRIC VEHICLE CHARGING STATION TP TWISTED-PAIR EWH ELECTRIC WATER HEATER TX TRANSFORMER F FUSED TYP TYPICAL (F) FUTURE UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY UR UNDERCOUNTER REFRIGERATOR V VOLTS VA VOLTS-AMPS VAV VARIABLE AIR VOLUME DESCRIPTION A: Priority Items to be Included in Total Bid Price A1 HIGH SPEED ROLL-UP DOORS AT VEHICLE ENTRIES A2 VISION LIGHT AT ELEVATORS A3 ADDISON ST. & CENTER ST. GROUND FLOOR LOBBY WALL FINISH - DURAROCK A4 ADDISON ST. & CENTER ST. GROUND FLOOR LOBBY WALL FINISH - CERAMIC TILE B: Bid Alternates B1 Lighting: a. ACCENT LIGHTING AT ROOF CANOPY - TYPE F5 b. ACCENT COLOR BLAST UPLIGHT ON BOTTOM OF SLABS c. GUARDRAIL LIGHTING AT 2ND FLOOR WALKWAYS INSTEAD OF d. STAIR DOWNLIGHTS AT SUPPORT BEAMS B2 B3 PHOTOVOLTAIC SYSTEM: a. INCREASE THE PV ARRAY TO MAXIMUM COVERAGE. b. BATTERY STORAGE FOR SMART PV ARRAY - BASED ON MAXIMUM SIZE c. DEDUCT FOR SWITCHGEAR REDUCTION FOR INITIAL PV ARRAY MICROGRID SYSTEM (ENTIRE) FLA FULL LOAD AMPERES FMC FLEXIBLE METAL CONDUIT FSD FIRE/SMOKE DAMPER HEAT DETECTOR INITIATING DEVICE, STRUCTURE MOUNTED ABOVE SUSPENDED CEILING TO SURFACE JUNCTION BOX. VFD VARIABLE FREQUENCY DRIVE FSEC FOOD SERVICE EQUIPMENT CONTRACTOR VM VENDING MACHINE MANUAL PULL STATION INITIATING DEVICE, WALL MOUNTED AT +48" UON. FRAP FIREMAN'S REMOTE ANNUNCIATOR PANEL W WATTS MOTOR OPERATED FIRE/SMOKE DAMPER 'FSD', NIEC. SYMBOL DENOTES INTERFACE FOR POWER, CONTROL AND POSSIBLY MONITORING CONNECTIONS FROM FIRE ALARM SYSTEM. ALSO, INCLUDES LOCAL POWER DISCONNECT MEANS. 'ES' BY FSD INDICATES END SWITCH CONNECTIONS FOR MONITORING BOTH 'OPEN' AND 'CLOSED POSITIONS. ADJACENT NUMBER INDICATES QUANTITY OF ACTUATORS AND END SWITCH GROUPS REQUIRING CONNECTION PER FSD, IF MORE THAN 1. WAP WIRELESS ACCESS POINT G GROUND WH WATER HEATER GB GROUND BUS WP WEATHERPROOF GD GARBAGE DISPOSAL 2SP TWO SPEED GFCI GROUND FAULT CIRCUIT INTERRUPTER 1Ø 1 PHASE SPRINKLER SYSTEM WATER FLOW SWITCH, NIEC. SYMBOL DENOTES INTERFACE FOR MONITORING CONNECTION FROM FIRE ALARM SYSTEM. GND GROUND 3Ø 3 PHASE GRAP GENERATOR REMOTE ANNUNCIATOR PANEL 1P 1 POLE GWH GAS WATER HEATER 2P 2 POLE HPC HIGH PRESSURE CONTACT SWITCH 3P 3 POLE HVAC HEATING,VENTING AND AIR CONDITIONING 3W 3 WIRE 4W 4 WIRE IMC INTERMEDIATE METAL CONDUIT IWH INSTANTANEOUS OR POINT OF USE WATER HEATER JB JUNCTION BOX END-OF-LINE RESISTOR. CROSSMARKS ON BRANCH CIRCUIT CONDUIT RUNS INDICATE THE QUANTITY OF CONDUCTORS AS FOLLOWS (GROUND CONDUCTORS ARE NOT NOTED, BUT SHOULD BE INCLUDED IN EVERY CONDUIT WITH POWER CONDUCTORS): MAGNETIC TYPE DOOR HOLD OPEN/RELEASE DEVICE, WALL MOUNTED, NIEC. SYMBOL DENOTES INTERFACE FOR POWER AND CONTROL CONNECTIONS FROM FIRE ALARM SYSTEM. AUDIBLE NOTIFICATION APPLIANCE, WALL MOUNTED, 6" BELOW CEILING OR +80" AFF, WHICHEVER IS LOWER. E0.2 ELECTRICAL SCHEDULES E0.3 TITLE 24 E0.4 TITLE 24 E0.5 TITLE 24 E2.1 GROUND LEVEL POWER AND SIGNAL PLAN E2.2 SECOND LEVEL POWER AND SIGNAL PLAN E2.3 THIRD LEVEL POWER AND SIGNAL PLAN VISIBLE NOTIFICATION APPLIANCE, CEILING MOUNTED IN FLUSH BACK BOX. NUMBER ASSOCIATED WITH 'cd' REPRESENTS CANDELA RATING OF STROBE. E2.4 FOURTH LEVEL POWER AND SIGNAL PLAN E2.5 FIFTH LEVEL POWER AND SIGNAL PLAN AUDIBLE/VISIBLE NOTIFICATION APPLIANCE, CEILING MOUNTED IN FLUSH BACK BOX. NUMBER ASSOCIATED WITH 'cd' REPRESENTS CANDELA RATING OF STROBE. E2.6 SIXTH LEVEL POWER AND SIGNAL PLAN E2.7 SEVENTH LEVEL POWER AND SIGNAL PLAN E2.8 ROOF POWER AND SIGNAL PLAN E3.1 GROUND LEVEL LIGHTING PLAN E3.2 SECOND LEVEL LIGHTING PLAN E3.3 THIRD LEVEL LIGHTING PLAN E3.4 FOURTH LEVEL LIGHTING PLAN E3.5 FIFTH LEVEL LIGHTING PLAN E3.6 SIXTH LEVEL LIGHTING PLAN E3.7 SEVENTH LEVEL LIGHTING PLAN E3.8 ROOF LIGHTING PLAN E4.1 ENLARGED PLANS E5.1 SINGLE LINE DIAGRAMS E5.2 PANEL SCHEDULES E5.3 SINGLE LINE LOW VOLTAGE DIAGRAMS E6.1 ELECTRICAL DETAILS E6.2 ELECTRICAL DETAILS E6.3 ELECTRICAL DETAILS E6.4 ELECTRICAL DETAILS VISIBLE NOTIFICATION APPLIANCE, WALL MOUNTED, 6" BELOW CEILING OR +80" AFF, WHICHEVER IS LOWER. NUMBER ASSOCIATED WITH 'cd' REPRESENTS CANDELA RATING OF STROBE. TWO PIECE SURFACE METAL RACEWAY, MOUNTED AS NOTED IN PLANS. CABLE TRAY, CABLE RUNWAY OR LADDER RACK SUSPENDED FROM STRUCTURE ABOVE. REFER TO PLANS FOR SIZE AND MOUNTING. AUDIBLE NOTIFICATION APPLIANCE, CEILING MOUNTED IN FLUSH BACK BOX. NAME 2004 NUMBERED SHEET NOTE, APPLIES TO DRAWING CONTAINING NOTES ONLY. EQUIPMENT IDENTIFICATION TAG: ITEM FURNISHED AND INSTALLED UNDER ANOTHER SECTION AND WIRED UNDER THIS SECTION. A 2-F3 A ALARM MONITORING CONTACT, MOUNTED AS NOTED ON PLANS. EL ELECTRIC MORTISE DOOR LOCK, NIEC, BUT WIRED UNDER THIS DIVISION. ES ELECTRIC DOOR STRIKE, NIEC, BUT WIRED UNDER THIS DIVISION. ML ELECTROMAGNETIC DOOR LOCK, NIEC, BUT WIRED UNDER THIS DIVISION. EP ELECTRIFIED PANIC HARDWARE, NIEC, BUT WIRED UNDER THIS DIVISION. MP MECHANICAL PANIC HARDWARE, NIEC, BUT WIRED UNDER THIS DIVISION. RX REQUEST-TO-EXIT SWITCH, NIEC, FURNISH WITH DOOR HARDWARE AND WIRED UNDER THIS DIVISION. P POWER TRANSFER HINGE, NIEC. R DOOR RELEASE MOTION SENSOR, WALL OR CEILING MOUNTED ABOVE DOOR, UON. D DURESS STATION, MOUNTED AS NOTED ON PLANS. M AREA MOTION SENSOR, CEILING MOUNTED, UON. M AREA MOTION SENSOR, WALL MOUNTED, +84" UON. GB GLASS BREAK DETECTOR, CEILING MOUNTED, UON. CR CARD READER CONTROLLER, WALL MOUNTED, +36" UON. K KEY PAD CONTROLLER, WALL MOUNTED, +42" UON. PS REMOTE MOUNTED POWER SUPPLY FOR LOW-VOLTAGE EQUIPMENT CONNECTIONS. FEEDER SIZE. REFER TO FEEDER SCHEDULE. DETAIL REFERENCE: FIXTURE IDENTIFICATION TAG: FIXTURE TYPE QUANTITY DRAWING TITLE SYMBOLS LIST AND DRAWING INDEX FIREMAN'S TELEPHONE JACK, WALL MOUNTED, +42" UON. 1 DRAWING NUMBER E0.1 AUDIBLE/VISIBLE NOTIFICATION APPLIANCE, WALL MOUNTED, 6" BELOW CEILING OR +80" AFF, WHICHEVER IS LOWER. NUMBER ASSOCIATED WITH 'cd' REPRESENTS CANDELA RATING OF STROBE. E2.1, E4.1 E2.1, E3.1 E2.1 E2.1, E3.1 FIREMAN'S FAN CONTROL PANEL CONDUIT SLEEVE, WITH INSULATING BUSHINGS. SHEET NUMBER DETAIL DESIGNATION INCLUDE IN TOTAL BID PRICE, PROVIDE BREAKOUT COST 1A TENANT IMPROVEMENTS FOR ART DISPLAY 1B AUDIO VISUAL FOR ART DISPLAY 2 TENANT IMPROVEMENTS FOR BIKE STATION, CAFÉ AND BIKE LINK FFCP EOL N/A N/A N/A N/A E2.8 E2.1, E4.1 E5.1 FIRE ALARM JUNCTION BOX DIFFERENTIAL PRESSURE SWITCH, NIEC. SYMBOLS DENOTES INTERFACE FOR MONITORING CONNECTION FROM FIRE ALARM SYSTEM TO ANNUNCIATE FAN OPERATION. INCLUDE A REMOTE MOUNTED ADDRESSABLE MONITORING MODULE AT EACH LOCATION. ELECTRICAL DOCUMENT LOCATION E3.8 E3 SERIES E3.2 E3 SERIES FAJB REMOTE MOUNTED SINGLE INPUT, ADDRESSABLE, MONITORING MODULE FOR INITIATING CIRCUIT CONNECTION. ONE CATEGORY 6 CABLE, FIXED POSITION IP CAMERA, MOUNTED AS NOTED ON PLANS. Architecture / Engineering / Consulting 560 - 14th Street Suite 300 Telephone 510 473 0300 Consulting Engineers THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 Revision Date Date Project No. Drawn By Checked By Scale Drawing Title: SYMBOL LIST AND DRAWING INDEX ONE CATEGORY 6 CABLE, PAN/TILT/ZOOM (PTZ) IP CAMERA, MOUNTED AS NOTED ON PLANS. SECURITY SYSTEM MONITOR/S. NVR NETWORK VIDEO RECORDER/SERVER. Oakland, CA 94612 Fax 510 473 0310 ISSUE KEY: ISSUED AS PART OF A SET ALLOWANCES: PARKING ACCESS CONTROL & EQUIPMENT WILL BE NOTED AS AN ALLOWANCE FOR THE CONTRACTOR TO CARRY IN THE BID. INSTALLTAION BY CONTRACTOR. CA 94704 Oakland Irvine Los Angeles FIRE ALARM CONTROL PANEL DPS PS BERKELEY, FACP REMOTE MOUNTED PROGRAMMABLE CONTROL RELAY MODULE FOR ADDRESSABLE CONTROL. MULTI-OUTLET TWO PIECE SURFACE RACEWAY; TYPE, DEVICE SPACING AND MOUNTING AS NOTED ON PLANS. EMERGENCY GENERATOR. DMU BFC CR 1. NO CROSSMARKS INDICATES TWO #12 AWG CONDUCTORS, UON. 2. THREE TO SIX CROSSMARKS INDICATES THE QUANTITY OF #12 AWG CONDUCTORS, UON. 3. SEVEN OR MORE CROSSMARKS INDICATES THE QUANTITY OF #10 AWG CONDUCTORS, UON. AUTOMATIC TRANSFER/BY-PASS ISOLATION SWITCH. NORMALLY CLOSED CONTACT. NEW AIR PRESSURE SWITCH FOR PRE ACTION SPRINKLER SYSTEMS, NIEC. SYMBOL DENOTES INTERFACE FOR MONITORING CONNECTION FROM FIRE ALARM SYSTEM. INCLUDE A REMOTE MOUNTED ADDRESSABLE MONITORING MODULE AT EACH LOCATION. CONDUIT CAPPED OR STUBBED WITH INSULATED BUSHINGS. LIGHTING CONTROL OCCUPANCY SENSOR WITH SINGLE DIMMER, WALL MOUNTED, +42" UON. NORMALLY OPEN CONTACT. (N) REMOTE MOUNTED DUAL INPUT, ADDRESSABLE, MONITORING MODULE FOR INITIATING CIRCUIT CONNECTION. CONDUIT TURNED UP CONTROL STATION, WALL MOUNTED, +42" UON. CONTROL CONTACTOR. BUILDING AUTOMATION SYSTEM DM CONDUIT HOMERUN, CONTINUOUS RUN TO PANEL OR EQUIPMENT CABINET. LIGHTING CONTROL OCCUPANCY SENSOR WITH DUAL LEVEL SWITCHING, WALL MOUNTED, +42" UON. ETD SURGE PROTECTION DEVICE, 'SPD'. BAS CONDUIT RUN EXPOSED ON WALL OR CEILING. LOW-VOLTAGE LIGHTING CONTROL SWITCHING STATION, WALL MOUNTED, +42" UON. REFER TO PLANS AND SCHEDULES FOR DEVICE QUANTITIES AND RELAYS CONTROLLED EM. SPD MICROWAVE SPRINKLER SYSTEM POST INDICATING VALVE 'PIV', NIEC. SYMBOL DENOTES INTERFACE FOR MONITORING CONNECTION FROM FIRE ALARM SYSTEM. INCLUDE A REMOTE MOUNTED ADDRESSABLE MONITORING MODULE AT PIV. CONDUIT RUN CONCEALED IN SLAB, UNDER SLAB OR UNDERGROUND. CURRENT TRANSFORMERS. NORM. MW SPRINKLER SYSTEM TAMPER SWITCH, NIEC. SYMBOL DENOTES INTERFACE FOR MONITORING CONNECTION FROM FIRE ALARM SYSTEM. WALL BOX DIMMER SWITCH, +42" UON. SIZED PER CONNECTED LOAD ON PLANS AND FURNISHED FOR LAMP SOURCE SERVED. PROVIDED FOR DE-RATING WHEN INSTALLED GANGED LOCATIONS. LINE-VOLTAGE MULTIPLE GANG SWITCHING STATION, WALL MOUNTED, 42" UON. REFER TO PLANS FOR DEVICE QUANTITIES AND TYPES. M 2 MANUAL MOTOR STARTER SWITCH WITH THERMAL OVERLOAD ELEMENT, MOUNTED ADJACENT TO MOTOR. S L F STEPLIGHT FIXTURE, WALL MOUNTED. SINGLE-POLE, SINGLE-THROW, EXPLOSION PROOF SWITCH, WALL MOUNTED, +42" UON. GROUND FAULT ALARM, NO SHUNT TRIP. AUTOMATIC OR MANUAL TRANSFER SWITCH. AUTOMATIC TRANSFER SWITCH HEAT DETECTOR INITIATING DEVICE, CEILING MOUNTED ON FLUSH OR SURFACE JUNCTION BOX. PILOT LIGHT, SINGLE-POLE, SINGLE-THROW SWITCH, WALL MOUNTED, +42" UON. EP S M1 POTENTIAL TRANSFORMERS. ATS PROJECTED BEAM SMOKE DETECTOR INITIATING DEVICES TO INCLUDE TRANSMITTER, BR RECEIVER AND REMOTE INDICATOR STATION, WALL OR PENDANT MOUNTED IN FLUSH OR SURFACE JUNCTION BOX AS NOTED ON PLANS. BT=BEAM TRANSMITTER, BR=BEAM RECEIVER. BT LINEAR SIGN LIGHT FIXTURE, STANCHION MOUNTED ABOVE GRADE. INDICATES ELECTRICALLY OPERATED WHEN ASSOCIATED WITH CIRCUIT BREAKER. CONNECTION TO GROUND. TWO CATEGORY 6 CABLES U.O.N.,TELECOMMUNICATION DEVICE, MOUNTED ABOVE ACCESSIBLE CEILING IN SURFACE MOUNT BOX. SINGLE-HEAD AREA POST-TOP LIGHT FIXTURE WITH POLE, MOUNTED TO CONCRETE BASE. KEY-OPERATED, SINGLE-POLE, SINGLE-THROW SWITCH, WALL MOUNTED, +42" UON. SWITCH FURNISHED UNDER ANOTHER DIVISION, BUT INSTALLED AND WIRED UNDER THIS DIVISION, WALL MOUNTED, +42" UON. TC S TRANSFORMER. MANUAL TRANSFER SWITCH SMOKE DETECTOR INITIATING DEVICE, IN-DUCT MOUNTED TYPE AT, DUCTED FSD'S. GROUND WELL MOUNTED FLUSH IN FINISHED GRADE. F S MEDIUM-VOLTAGE, INDIVIDUALLY DRAW-OUT MOUNTED VACUUM CIRCUIT BREAKER. UTILITY METER. MTS SMOKE DETECTOR INITIATING DEVICE, STRUCTURE MOUNTED ABOVE SUSPENDED CEILING TO SURFACE JUNCTION BOX. LIGHT FIXTURE BOLLARD, MOUNTED TO CONCRETE BASE. MANUAL MOTOR STARTER/DISCONNECT SWITCH, MOUNTED ADJACENT TO MOTOR. D S GROUND FAULT RELAY WITH SHUNT TRIP. MAIN TELECOM GROUND BUS AMPERE OVERCURRENT TRIP (WHEN APPLIED TO CIRCUIT BREAKERS) SMOKE DETECTOR INITIATING DEVICE, CEILING MOUNTED ON FLUSH OR SURFACE JUNCTION BOX. AREA LIGHT FIXTURE, SURFACE OR RECESSED MOUNTED TO WALL. M S INDIVIDUALLY DRAW-OUT MOUNTED INSULATED-CASE OR POWER CIRCUIT BREAKER. INDICATES KIRK-KEY INTERLOCK WHEN ASSOCIATES WITH OVERCURRENT PROTECTION DEVICES. ADJACENT NUMBER CORRESPONDS WITH DEVICE INTERLOCK. MTGB AT SMOKE DETECTOR INITIATING DEVICE, DUCT-MOUNTED TYPE WITH SAMPLING TUBE, LOCATED AT SUPPLY AIR FANS 2000cfm AND LARGER. TWO-HEAD AREA LIGHT FIXTURES WITH BRACKET ARMS AND POLE, MOUNTED TO CONCRETE BASE. SINGLE-POLE, SINGLE-THROW SWITCH, WALL MOUNTED, +42" UON. K S INDICATES SHUNT TRIP WHEN ASSOCIATED WITH OVERCURRENT PROTECTION DEVICES. TWO CATEGORY 6 CABLES U.O.N.,TELECOMMUNICATION DEVICE, MOUNTED IN FLOOR MONUMENT. QUANTITY OF DATA AND/OR VOICE TELECOMMUNICATIONS DEVICES. #D/#V SINGLE-HEAD AREA LIGHT FIXTURE WITH BRACKET ARM AND POLE, MOUNTED TO CONCRETE BASE. ELECTRIFIED FURNITURE PARTITION POWER FEED, MOUNTED IN FIRE-RATED POKE-THRU FLOOR FITTING WITH KO IN COVER TO ACCEPT FURNITURE WHIP. P FOUR-WAY SWITCH, WALL MOUNTED, +42" UON. INDICATES COMMUNICATION NETWORK WIRING WHEN ASSOCIATED WITH CIRCUIT BREAKER. ALUMINUM ONE CATEGORY 6 CABLE U.O.N., EMERGENCY TELEPHONE WITH BLUE LIGHT. EXTERIOR: ELECTRIFIED FURNITURE PARTITION COMBINATION POWER/TELECOMMUNICATION FEEDS, MOUNTED IN FLUSH FLOOR BOX WITH KO'S IN COVER TO ACCEPT FURNITURE WHIPS BOLTED PRESSURE OR HIGH PRESSURE CONTACT SWITCH. C EMPTY CONDUIT AL EXIT SIGN LIGHT FIXTURE, CEILING OR WALL MOUNTED WITH DIRECTIONAL ARROWS AS NOTED ON PLANS. WORD 'EXIT' TO BE LOCATED IN SHADED FACE(S). ELECTRIFIED FURNITURE PARTITION POWER FEED, WALL MOUNTED, +18" UON. CONSISTS OF 4 11/16" SQ. X 2 1/8" DEEP. JUNCTION BOX, SINGLE GANG RING, AND STAINLESS STEEL COVER PLATE WITH KO TO ACCEPT FURNITURE WHIP. P THREE-WAY SWITCH, WALL MOUNTED, +42" UON. INDICATES INTEGRAL GROUND FAULT RELAY WHEN ASSOCIATED WITH CIRCUIT BREAKER. MTC ASYMMETRIC INTERRUPTING CURRENT TWO CATEGORY 6A CABLES, WIRELESS ACCESS POINT, CEILING MOUNTED. FULL SHADING OF ANY FIXTURE INDICATES STANDBY/CRITICAL LIGHTING. INDICATES CABLE TERMINATION LUGS AT EQUIPMENT BUS. G EMPTY AIC TWO CATEGORY 6A CABLES, WIRELESS ACCESS POINT, WALL MOUNTED, 8" BFC UON. DUPLEX CONVENIENCE RECEPTACLE DEVICE, CORD OR REEL HUNG FROM STRUCTURE ABOVE. TYPE AS NOTED ON PLANS. POWER/TELECOMMUNICATION POLE, MOUNTED TO EXTEND FROM FLOOR TO CEILING. TYPE AS NOTED ON PLANS. INDIVIDUALLY FIXED MOUNTED INSULATED-CASE OR POWER CIRCUIT BREAKER. MT TWO CATEGORY 6 CABLES U.O.N.,TELECOMMUNICATION DEVICE, MOUNTED IN FIRE-RATED POKE-THRU FLOOR FITTING. EMERGENCY SELF-POWERED BATTERY PACK WITH LIGHT FIXTURE HEADS AS NOTED ON PLANS OR IN FIXTURE SCHEDULE. COMBINATION POWER/TELECOMMUNICATION DEVICE, MOUNTED IN FLUSH FLOOR BOX. TYPE AS NOTED ON PLANS OR IN SPECIFICATIONS. DEVICE BRANCH CIRCUIT POWER DISTRIBUTION BOX FOR INTERFACE BETWEEN MULTI-CIRCUIT HOMERUN AND MC CABLE BRANCH CIRCUITING. MINIMUM BOX SIZE IS 10"X10"X4" DEEP. BOX MOUNTED FROM STRUCTURE ABOVE IN ACCESSIBLE CEILING SPACE. ADJACENT NUMBERS INDICATE CIRCUITS AVAILABLE AT BOX. GROUP MOUNTED MOLDED CASE CIRCUIT BREAKER. MAIN LUGS ONLY ABOVE FINISHED FLOOR LINEAR TRACK SYSTEM WITH PLUG-IN ADJUSTABLE LIGHT FIXTURE HEADS. TRACK SHALL BE EITHER RECESSED, SURFACE OR PENDANT MOUNTED TO CEILING AS NOTED IN FIXTURE SCHEDULE. COMBO EXIT SIGN AND EGRESS LIGHTING FIXTURE, CEILING OR WALL MOUNTED WITH ARROWS AS NOTED ON PLANS OR IN FIXTURE SCHEDULE. DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FLOOR MONUMENT. ELECTRICAL VEHICLE CHARGING STATION, PEDESTAL MOUNTED. MEDIUM-VOLTAGE LOAD INTERRUPTER SWITCH. MLO AFF ELECTRIFIED FURNITURE PARTITION TELECOMMUNICATION CABLE FEEDS, MOUNTED IN FIRE-RATED POKE-THRU THRU FLOOR FITTING WITH 1 1/4" KO'S IN COVER TO ACCEPT FURNITURE WHIPS. DECORATIVE CHANDELIER OR BOWL TYPE FIXTURE, PENDANT MOUNTED. DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED FLUSH IN CEILING. DRIVEN GROUND ROD IN GROUND WELL WITH COVER. FUSED SWITCH. MOTOR CONTROL CENTER ELECTRIFIED FURNITURE PARTITION COMBINATION POWER/TELECOMMUNICATION FEEDS, MOUNTED IN FLUSH FLOOR BOX WITH KO'S IN COVERS TO ACCEPT FURNITURE WHIPS. TELECOMMUNICATIONS WHIP SHALL BE 1 1/4" MINIMUM. P T HALF SHADING OF ANY FIXTURE INDICATES LIFE SAFETY/EGRESS LIGHTING. BRANCH CIRCUIT POWER DISTRIBUTION BOX OF MANUFACTURED WIRING SYSTEM WITH MODULAR CONNECTORS FOR INTERFACE TO BRANCH CIRCUIT MODULAR CABLE SETS AND CABLE OR CONDUIT HOMERUN. BOX MOUNTED FROM STRUCTURE ABOVE IN ACCESSIBLE CEILING SPACE. ADJACENT NUMBERS INDICATE CIRCUITS AVAILABLE AT BOX. MCC DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FLUSH FLOOR BOX. DRIVEN GROUND ROD. ELECTRICAL VEHICLE CHARGING STATION, WALL MOUNTED. MAIN CIRCUIT BREAKER ELECTRIFIED FURNITURE PARTITION TELECOMMUNICATION CABLE FEED, WALL MOUNTED, +18" UON. CONSISTS OF 4 11/16" SQ. X 2 1/8" DEEP. JUNCTION BOX, SINGLE GANG RING, AND STAINLESS STEEL COVERPLATE WITH 1 1/4" KO AND GROMMET. WRAP EXPOSED CABLE WITH SPIRAL WRAP. LINEAR WALLWASH LIGHT FIXTURE, RECESSED IN CEILING. DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED FLUSH IN CEILING. VARIABLE FREQUENCY DRIVE FURNISHED AND INSTALLED UNDER ANOTHER DIVISION. PROVIDE POWER SERVICE CONNECTION UNDER THIS DIVISION AS NOTED ON PLANS. MCB COMBINATION POWER/TELECOMMUNICATION DEVICES, MOUNTED IN FIRE-RATED POKE-THRU FLOOR FITTINGS. TYPE AS NOTED ON PLANS OR IN SPECIFICATIONS. ADJUSTABLE ACCENT LIGHT FIXTURE, SURFACE OR PENDANT MOUNTED. PACKAGE MOTOR CONTROLLER OR STARTER FURNISHED AND INSTALLED UNDER ANOTHER DIVISION WITH EQUIPMENT CONTROLLED. PROVIDE SINGLE-POINT POWER SERVICE CONNECTION UNDER THIS DIVISION AS NOTED ON PLANS. VFD AMPERE OVERCURRENT FRAME SIZE (WHEN APPLIED TO CIRCUIT BREAKERS) OR AMPERE FUSE SIZE (WHEN APPLIED TO FUSES) TWO CATEGORY 6 CABLES U.O.N.,COMBINATION POWER/TELECOMMUNICATION DEVICES, MOUNTED IN FLUSH FLOOR BOX. TYPE AS NOTED ON PLANS OR IN SPECIFICATIONS. ADJUSTABLE ACCENT LIGHT FIXTURE, RECESSED IN CEILING. P AF TWO CATEGORY 6 CABLES U.O.N.,TELECOMMUNICATION DEVICE, MOUNTED IN FLUSH FLOOR BOX. DOWNLIGHT FIXTURE, RECESSED IN CEILING. DUPLEX CONVENIENCE RECEPTACLE DEVICE, WALL MOUNTED, +18" UON. INDOOR EXHAUST FAN MOTOR, SINGLE PHASE. MAKE POWER CONNECTIONS TO INCLUDE JUNCTION BOX MOUNTED MANUAL MOTOR STARTER AND DISCONNECT ADJACENT TO FAN WITH 2 #12 CONDUCTORS PLUS GROUND IN 1/2" FLEXIBLE CONDUIT BETWEEN STARTER AND MOTOR. F TWO CATEGORY 6 CABLES U.O.N., TELECOMMUNICATION DEVICE, WALL MOUNTED OVER COUNTER, 6" ABOVE BACK SPLASH, UON. STRIP LIGHT FIXTURE, SURFACE MOUNTED VERTICALLY ON WALL OR IN COVE. SINGLE-PLEX CONVENIENCE RECEPTACLE DEVICE, WALL MOUNTED, +18" UON. ELECTRIC MOTOR, NIEC. MAKE POWER CONNECTIONS ONLY AS NOTED ON PLANS. MAIN BUILDING GROUND BUS BID ADDENDUM 3 DRY-TYPE STEP-DOWN TRANSFORMER, FLOOR MOUNTED 3Ø,480-120/208V, UON. MBGB 04.01.2016 JUNCTION BOX, MOUNTED ON CONDUIT STANCHION FLOOR PENETRATION, +12" UON. ARC FAULT CIRCUIT INTERRUPTER BID ADDENDUM 2 J AFI 03.25.2016 PANELBOARD, 120/208V, FLUSH MOUNTED IN WALL. STRIP LIGHT FIXTURE, SURFACE MOUNTED IN ARCHITECTURAL CEILING COVE. LIGHTING CONTROL PANEL PERMIT RESUBMITTAL PANELBOARD, 120/208V, SURFACE MOUNTED ON WALL. LCP BID STRIP LIGHT FIXTURE, SURFACE OR PENDANT MOUNTED. ABOVE FINISHED CEILING 02.26.2016 JUNCTION BOX, SURFACE OR PENDANT MOUNTED TO STRUCTURE IN ACCESSIBLE CEILING SPACE. AFC 02.26.2016 J PANELBOARD, 277/480V, FLUSH MOUNTED IN WALL. TWO CATEGORY 6CABLES U.O.N., TELECOMMUNICATION DEVICE, WALL MOUNTED, +18" UON. PERMIT LIGHT FIXTURE, WALL MOUNTED. LIFE SAFETY CONTROL PANEL 11.20.2015 JUNCTION BOX, MOUNTED FLUSH IN CEILING. LSCP 65% CD SET J AMPERES 100% DD SET LIGHT FIXTURE, SURFACE OR PENDANT MOUNTED. A 10.15.2015 JUNCTION BOX, MOUNTED IN FLUSH FLOOR BOX. PANELBOARD, 277/480V, SURFACE MOUNTED ON WALL. ONE CATEGORY 6 CABLES, TELECOMMUNICATION DEVICE, WALL MOUNTED AT +42". 07.15.2015 J W 50% DD SET LIGHT FIXTURE, RECESSED IN CEILING. 06.26.2015 JUNCTION BOX, WALL MOUNTED, +18" UON. ISSUE TITLE J DATE SWITCHBOARD, DISTRIBUTION BOARD, SUBSTATION OR MOTOR CONTROL CENTER, FLOOR MOUNTED. Drawing No. E0.1 ARCHITECTURAL LIGHTING FIXTURE SCHEDULE FEEDER CONDUIT CONDUCTORS 9004 900 AMP,3 PHASE,4 WIRE 3-3.00" 3 SETS OF 4 #350 KCMIL 1 #2/0 PER SET - 9003 900 AMP,3 PHASE,3 WIRE 3-3.00" 3 SETS OF 3 #350 KCMIL 1 #2/0 PER SET - TYPE AF1 MFR. / CAT. NO. Ecosense # WWEA-12-30-120-6 Mounting Brackets - EXT-A-MNT-ADJ Jumper Cables - EXT3P-A-JMP-120-1 LAMP QTY / TYPE WATTS LED 5 W/LF 380 lm/LF 3000 K 80+ CRI VOLTS DESCRIPTION 120 LED linear wallwash, 6°x6°, IP66 AF2 Ecosense - Trov # L50-E-12-06-40-80MULT-15x35 Mounting Brackets - MNT-L-TRK-12 Mounting Clips - MNT-L-CLIP Jumper Cables - CBL-3P-L-UNV-01 LED 492 lm/LF 4000 K 80 CRI 6 W/LF 120 we-ef # 663-2621 LED 246 lm 3000 K 12 W LIGHTING FIXTURE SCHEDULE LOCATION Front of Screen LED linear wallwash, 15°x35°, multi-volt, IP66. 8004 800 AMP,3 PHASE,4 WIRE 3-3.00" 3 SETS OF 4 #300 KCMIL 1 #1/0 PER SET - 8003 800 AMP,3 PHASE,3 WIRE 2-3.00" 2 SETS OF 3 #500 KCMIL 1 #1/0 PER SET - 7004 700 AMP,3 PHASE,4 WIRE 2-3.50" 2 SETS OF 4 #500 KCMIL 1 #1/0 PER SET - 7003 700 AMP,3 PHASE,3 WIRE 2-3.00" 2 SETS OF 3 #400 KCMIL 1 #1/0 PER SET - 6004 600 AMP,3 PHASE,4 WIRE 2-3.00" 2 SETS OF 4 #350 KCMIL 1 #1 PER SET - 6003 600 AMP,3 PHASE,3 WIRE 2-2.50" 2 SETS OF 3 #350 KCMIL 1 #1 PER SET - 5004 500 AMP,3 PHASE,4 WIRE 2-2.50" 2 SETS OF 4 #250 KCMIL 1 #2 PER SET - 5003 500 AMP,3 PHASE,3 WIRE 2-2.00" 2 SETS OF 3 #250 KCMIL 1 #2 PER SET - 4504 450 AMP,3 PHASE,4 WIRE 2-2.50" 2 SETS OF 4 #4/0 1 #2 PER SET - 4503 450 AMP,3 PHASE,3 WIRE 2-2.00" 2 SETS OF 3 #4/0 1 #2 PER SET - 4004 400 AMP,3 PHASE,4 WIRE 1-3.50" 4 #500 KCMIL 1 #2 - 4003 400 AMP,3 PHASE,3 WIRE 1-3.00" 3 #500 KCMIL 1 #2 - 3504 350 AMP,3 PHASE,4 WIRE 1-3.50" 4 #500 KCMIL 1 #2 - 3503 350 AMP,3 PHASE,3 WIRE 1-2.50" 3 #400 KCMIL 1 #2 - 3004 300 AMP,3 PHASE,4 WIRE 1-3.00" 4 #350 KCMIL 1 #4 - 3003 300 AMP,3 PHASE,3 WIRE 1-2.50" 3 #350 KCMIL 1 #4 - 2754 275 AMP,3 PHASE,4 WIRE 1-3.00" 4 #300 KCMIL 1 #4 - 2753 275 AMP,3 PHASE,3 WIRE 1-2.50" 3 #300 KCMIL 1 #4 - 2504 250 AMP,3 PHASE,4 WIRE 1-2.50" 4 #250 KCMIL 1 #4 - 2503 250 AMP,3 PHASE,3 WIRE 1-2.00" 3 #250 KCMIL 1 #4 - 2254 225 AMP,3 PHASE,4 WIRE 1-2.50" 4 #4/0 1 #4 - 2253 225 AMP,3 PHASE,3 WIRE 1-2.00" 3 #4/0 1 #4 - 2004 200 AMP,3 PHASE,4 WIRE 1-2.00" 4 #3/0 1 #6 - 2003 200 AMP,3 PHASE,3 WIRE 1-2.00" 3 #3/0 1 #6 - 1754 175 AMP,3 PHASE,4 WIRE 1-2.00" 4 #2/0 1 #6 - 1753 175 AMP,3 PHASE,3 WIRE 1-1.50" 3 #2/0 1 #6 - 1504 150 AMP,3 PHASE,4 WIRE 1-1.50" 4 #1/0 1 #6 - 1503 150 AMP,3 PHASE,3 WIRE 1-1.50" 3 #1/0 1 #6 - 1254 125 AMP,3 PHASE,4 WIRE 1-1.50" 4 #1 1 #6 - 1253 125 AMP,3 PHASE,3 WIRE 1-1.25" 3 #1 1 #6 - 1004 100 AMP,3 PHASE,4 WIRE 1-1.25" 4 #2 1 #8 - 1003 100 AMP,3 PHASE,3 WIRE 1-1.25" 3 #2 1 #8 - 904 90 AMP,3 PHASE,4 WIRE 1-1.25" 4 #2 1 #8 - 903 90 AMP,3 PHASE,3 WIRE 1-1.25" 3 #2 1 #8 - 804 80 AMP,3 PHASE,4 WIRE 1-1.25" 4 #4 1 #8 - 803 80 AMP,3 PHASE,3 WIRE 1-1.00" 3 #4 1 #8 - 1 LIGHTING CONTROLS: To be determined. Provide appropriate dimming, power supply, and electronic ballast interfaces, coordinated with voltage. 704 70 AMP,3 PHASE,4 WIRE 1-1.25" 4 #4 1 #8 - 2 Contractor shall verify fixture mounting & coordination with final specified ceiling system. 703 70 AMP,3 PHASE,3 WIRE 1-1.00" 3 #4 1 #8 - 3 All fixtures shall be U.L. or ETL listed. - 4 Architect to verify all specified finishes. 604 60 AMP,3 PHASE,4 WIRE 1-1.25" 4 #6 1 #10 603 60 AMP,3 PHASE,3 WIRE 1-1.00" 3 #6 1 #10 - 504 50 AMP,3 PHASE,4 WIRE 1-1.00" 4 #8 1 #10 - 503 50 AMP,3 PHASE,3 WIRE 1-0.75" 3 #8 1 #10 - 404 40 AMP,3 PHASE,4 WIRE 1-0.75" 4 #8 1 #10 - 403 40 AMP,3 PHASE,3 WIRE 1-0.75" 3 #8 1 #10 - 304 30 AMP,3 PHASE,4 WIRE 1-0.75" 4 #10 1 #10 - 303 30 AMP,3 PHASE,3 WIRE 1-0.75" 3 #10 1 #10 - 204 20 AMP,3 PHASE,4 WIRE 1-0.50" 4 #12 1 #12 - 203 20 AMP,3 PHASE,3 WIRE 1-0.50" 3 #12 1 #12 - 154 15 AMP,3 PHASE,4 WIRE 1-0.50" 4 #12 1 #12 - 153 15 AMP,3 PHASE,3 WIRE 1-0.50" 3 #12 1 #12 - FEEDER SCHEDULE GENERAL NOTES: 1. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS WITH THHN/THWN INSULATION. 2. FEEDERS CONSISTING OF MULTIPLE SETS OF CONDUCTORS AND CONDUITS ARE TO BE PROVIDED WITH THE INDICATED SIZE GROUND CONDUCTOR IN EACH CONDUIT. AF3 Philips ColorBlast Powercore # 123-000021-06 LED 1471 lm 50W 120 LED RGB surface mounted wall wash, 86° beam spread, white housing, directed at bottom of slabs, multi-volt, IP66 Remarks: Controls--iPlayer 3. Coordinate with general building controls. Back of screen on structure levels 02-07 AF5 Philips eW Blast Powercore # 523-000069-14 LED 2398 lm 4000 K 82 CRI 50W 120 White LED surface mounted wall wash, 83° beam spread, white housing, multi-volt, dimmable, IP66. Top of crashwall on level 08 AF6 Amerlux Hornet High Power HORNET # HP-A14-18-LED-WT-TN120-FL-3000-9 Track - GES204-3 LED 1369 lm 3000K 97CRI 18W 120 LED track head, 28° beam spread, white finish, ELVdimming. Art Display AF7 Prudential Lighting # P4000 P4030-LED3-LO-FWA-TMW-D1-SCUNIV-MPCA-X1-DMD LED 5800 lm 3000 K 83 CRI 56W 120 LED pendant, 3" diameter, white finish, multi-volt, 0.1% dimming . Art Display Ecosense Trov # L50-E-48-06-40-90MULT-15x15 LED 492lm/LF 4000 K 90CRI 6 W/LF LED 492lm/LF 4000 K 90CRI 6 W/LF AF8 Ecosense Trov #L50-E-48-06-40-90MULT-ASYM AF8A LED linear graze, 15°x15°, multi-volt, IP66. 120 FINELITE # 619 WS-32 & 9-SO-3500-120-SCSF-2 CUSTOM CORNERS OR PRUDENTIAL P83-LEDREG4-LED4-LOR*=RGW-LP-SC-UNIV-X3B-2 CUSTOM CORNER OR NEORAY S123 DRP LO-35-TBD-XX-SC-120- LED 3500K/80CRI 9.3 WATTS/FT 120 60,000 HOURS DESCRIPTION LOCATION SURFACE OR MOUNTED LED STRIP. WITH FROSTED ACRYLIC UTILITY ROOMS LENS. 22 GAUGE DIE FORMED C.R.S.HOUSING. 92% REFLECTIVE WHITE POLYESTER POWDER COAT PAINT BONDED TO PHOSPHATE FREE MULTI STAGE PRETREATED METAL. ALL PARTS PAINTED AFTER FABRICATION TO INHIBIT CORROSION. CONSTANT CURRENT , CLASS 2 DRIVER. CONFORMS TO UL STD 1598. SUITABLE FOR DAMP LOCATIONS. 5 YEAR WARRANTEE. 4" WIDE BY 5" HIGH PERIMETER SLOT. REFLECTORS ARE DIE FORMED 24 GAUGE COLD ROLLED STEEL FINISHED IN A HIGH REFLECTANCE MATTE WHITE POWDER COAT PAINT. CASHIER OFFICES 47 120 1X4 X 3" SURFACE MOUNTED DIMMABLE TROFFER WITH FROSTED ACRYLIC LENS . 19 GAUGE HOUSING PAINTED 92% WHITE POLYESTER POWDER COATED WHITE PAINT. LED BARDS ARE ACCESSIBLE BELOW CEILING AND RATED AT 50,000 HOURS LIFE. F4 HE WILLIAMS # LLMS-41-L34/835-RD-DIM LED 80CRI/4000K 42 4100 LUMENS OR METALUX#4SNLED-L4-44SL-LW-UNIV-L8XXCD1-U OR PRUDENTIAL#R1-LED40-4-SAL-TMW-UNIVSUR-DM10 120 F5 LED HE WILLIAMS #96-4-L62/840DIM-120 OR METALUX# 4VT2-LD4-6-XX-UNIV-L840-CD1WL OR LITHONIA#VAP-6000LM-FST-WD-120-GZ1040K-80CRI 73 120 NARROW LED LED LENSED STRIP SERIES. 20 GAUGE DIE BIKE STORAGE FORMED HOUSING. FROSTED ROUND EXTRUDED MATTE ACRYLIC LENS. TEXTURED MATTE WHITE POLYESTER POWDER COATED PAINT BONDED TO PHOSPHATE-FREE MULTI-STAGE PRETREATED METAL. ALL PARTS PAINTED AFTER FABRICATIONTO INHIBIT CORROSION. CONSTANT CURRENT , CLASS 2 DRIVER. CONFORMS TO UL STD 1598. SUITABLE FOR DAMP LOCATIONS. 5 YEAR WARRANTEE. VAPORTIGHT LINEAR LED FIXTURE SURFACE MOUNTED. ELEVATOR SHAFT AND PIT F6/8' HE WILLIAMS # LLMS-68-L34/835-SQ-DIM LED 80CRI/4000K 64 6800 LUMENS OR PRUDENTIAL#S1-LED40-4-SAL-TMW-UNIVSUR-DM10 OR EUREKA FLARE # 3550 120 SIMILAR TO F4 BUT SQUARE AND 8'-0" LARGER RESTROOMS F6/4' LED 80CRI/4000K 42 HE WILLIAMS # LLMS-41-L/835-SQ-DIM 4100 LUMENS OR EUREKA FLARE # 3550 OR PRUDENTIAL#S1-LED40-4-SAL-TMW-UNIVSUR-DM10 120 SIMILAR TO F4 BUT SQUARE AND 4'-0" SMALLER RESTROOMS Bike Sign F7 NOT USED F8 KENALL TD17HO-DTS-5S-TP-GW-47L-40K8- LED 80CRI/4000K 54 6,671 LUMENS DCC-120-TL1000 OR McGRAW-EDISON TT-B4-LED-E1-WQ-8030 OR LITHONIA PGX LED-P3-T5R-120-SRM-TBDMOD 80CRI BERKELEY, CA 94704 Oakland Irvine Los Angeles Architecture / Engineering / Consulting 560 - 14th Street Suite 300 Telephone 510 473 0300 120 Oakland, CA 94612 Fax 510 473 0310 GARAGE SURFACE MOUNTED LED GARAGE FIXTURE. MARINE GRADE DIE CAST ALUMINUM HOUSING AND UV-STABLIZED POLYCARBONATE LENS. POLYESTER POWDER COAT FINISH ON ALL ALUMINUM COMPONENTS WITH FIVE-STEP PRE-TREATMENT TO WITHSTAND 1,000 HOUR SALT SPRAY TEST PER ASTM B117. DIRECT TO SURFACE MOUNTING MOUNTING OVER RECESSED JUNCTION BOX. 10 YEAR WARRANTEE. Consulting Engineers F8A KENALL TD17HO-DTS-5S-TP-GW-30L-40K8- LED 80CRI/4000K 34 6,271 LUMENS DCC-120-TL1000 OR McGRAW-EDISON TT-B3-LED-E1-WQ-803 OR LITHONIA PGX LED-P2-T5R-120-SRM-TBDMOD 80CRI 120 SIMILAR TO F8 BUT LOWER OUTPUT SURFACE MOUNTED LED GARAGE FIXTURE. NOTE FIXTUES MATCH PICTURES ABOVE F9 LED 80CRI/4000K 8W/LF AION# HOUSING:AT845 AS-F-W96" LIGHT ENGINE# 3450 D100 DC DRIVER OR CELESTIAL SERPENS GX SERIES # SERFX-277-300 OR APPROVED EQUAL BY INTER-LUX 120 RECESSED LINEAR FIXTURE WASHING INTERIOR WALLS. FIXTURE PUBLIC SHALL BE IN CONTINUOUS ROWS, IN ARCHITECTURAL SLOT. WITH CORRIDORS AND AT ELEVATOR REMOTE DRIVERS TBD. LOBBIES. F10 LED 3500K/80CRI 33W PHILIPS LIGHTOLIER #C6X6L-30-N-1-VB60,000 HOURS Z10V C6X6-3000-DL-4000-WH-WH-WRATED LIFE CA6X6FMR-VB OR LITHONIA GOTHAM #ICO-SQ-40-30-4WRFLLD-50D-120 OR COOPER IRIS P406TAT-EDC4X41-E4DCMW 120 6" SQUARE APERTURE WHITE LED WALL WASHER, RECESS DEPTH ELEVATOR 6-1/2" INCLUDING LIGHT ENGINE DO NOT INSTALL INSULATION LOBBY ABOVE OR WITHIN 3" OF LUMINAIRE. 0.09" CLEAR BOROSILICATE GLASS. SELF FLANGE WHITE REFLECTOR UL LISTED FOR WET LOCATIONS F11 LED 80CRI/4000K 8W/LF AION# HOUSING:AT402 AS-F-W96" LIGHT ENGINE# 3450 D100 DC DRIVER DRIVER OR CELESTIAL SERPENS GX SERIES # SERFX-277-300 OR APPROVED EQUAL BY INTER-LUX 120 FIXTURE MOUNTED WITHIN CUSTOM ENCLOSURE WITHIN STAIR RAIL ASSEMBLY. REMOTE DRIVER LOCATION IN STAIR. EXACT LOCATION TO BE DETERMINED F12 KENALL #N548-C-1-45L40K-DCC-1-120-SA LED 4000K OR INDATECH#HXPF4-90-U-35-BCK OR BEGHELLI-BX910LED-4-HT-50W0WT40-120PM 120 SURFACE MOUNTED ENCLOSED AND GASKETED FIXTURE WITH ROOF UNDER SURFACE MOUNT ADAPTER. MOUNT TO THE BOTTOM WEB OF THE TRUSS ROOF TRUSS SYSTEM. PROVIDE SHEET METAL SHROUD ABOVE FIXTURE TO ALLOW WET LISTING, PAINTED PER ARCHITECT'S DIRECTION. FEED CONDUIT FROM ENDS. ONE-PIECE SEAM WRAPAROUND POLYCARBONATE LENS. F13 LED 80CRI/4000K 8W/LF AION# HOUSING:AT845 AS-F-W96" LIGHT ENGINE# 3450 D100 DC DRIVER OR CELESTIAL SERPENS GX SERIES # SERFX-277-300 OR APPROVED EQUAL BY INTER-LUX 120 7'-0" & 12'-0" SURFACE MOUNTED LED FIXTURE TO WASH MURALS. ELEVATOR MURAL WALLS F14 METEOR # CCS-50-40K-U-V-100-B-SU-OUT- LED 80CRI/4000K 55 DF OR LITHONIA GOTHAM EVO-CYL-50-30-6ARWD-LD OR WE-EF# DAC220-LED-630-1253 MOD WIDE SPREAD LENS 120 SURFACE LED 6" X 13" CYLINDER. SURFACE MOUNTED . 100 DEGREE BEAM, DIE CAST ALUMINUM BODY, MACHINED ALUMINUM MOUNTING PLATE, STAINLESS STEEL SCREWS, CLEAR GLASS. 5 YEAR WARRANTY. IP65, IK 08 LISTED. CANOPY AT ROOF ELEVATOR F15 METEOR # CCS-50-40K-U-V-60-B-SU-OUT OR LITHONIA GOTHAM EVO-CYL-50-30-6ARWD-LD OR WE-EF# DAC220-LED-630-1253 MOD SPREAD LENS LED 80CRI/4000K 55 120 SIMILAR TO F14 BUT 60 DEGREE BEAM SPREAD. CANOPY AT LOWER LEVEL SFX PHILIPS LIGHTOLIER #EEXSSCOR EQUAL BY LITHONIA OR COOPER LED 3 120 SURFACE OR PENDANT MOUNTED EXIT SIGN, DIE-CAST ALUMINUM EXIT PATHS HOUSING. SFX2 PHILIPS ER60MLD-3-R-WA-PM OR EQUAL BY LITHONIA OR COOPER LED 8 120 SURFACE MOUNTED WEATHERPROOF LED EXIT SIGN EXTERIOR LOCATIONS FEX EMERGI-LITE #W-12SV224M-2-LJ-D OR EQUAL BY LITHONIA OR COOPER LED 6 120 UNIT EMERGENCY BATTERY LIGHT WITH LED LAMPS. 12VOLT, 24 WATTS LEAD CALCIUM BATTERY, NEMA 4X. ELECTRICAL, GENERATOR ROOMS 7 See architectural drawings for mounting dimensions and/or details SUBMITTALS: as part of this work the Contractor shall, within 15 days after award of the Contract, sumbit a complete material list of all lighting fixtures, miscellaneous materials, 8 and controls proposed to be furnished and installed. This submittal shall include manufacturer’s specifications, cut sheets, and other data required to demonstrate compliance with specified requirements. Submittals shall be in PDF format. No substitution of specified fixture, lamp or controls manufacturer will be acceptable without specific prior approval of the Architect. If Contractor makes a substitution without said prior approval, he shall replace the substituted item with the specified item and to the Architect's labor costs involved in re-aiming fixtures, traveling to the site, etc.) without any 9 additional shall bear all associated costs (including but not limited to the Architect's labor costs involved in re-aiming fixtures, traveling to the site, etc.) without any additional charge to the Owner. 10 Any fluorescent lamp on dimming ballast must be operated at full output for a minimum of 100 hours before being dimmed. Any non-fluorescent lamp or non-LED used during the course of construction shall be replaced and re-lamped prior to project turnover to owner. The cost of lamp replacement shall be incurred by Contractor. 12 Remote transformers, power supplies, and ballasts to be located in well ventilated location as required. Remote transformers shall be UL listed with re-settable secondary side circuit breaker protection per NEC. Transformer size and secondary breaker capacity shall be determined by Electrical Contractor for each condition. At remote transformers, minimum secondary wire size shall be #10 stranded THHN unless noted otherwise. Maximum secondary run shall be less than wire size to be acceptable. 20LF for 150VA load. For greater load or longer run, indicates a smaller provide voltage drop calculation and proposed wire size unless voltage drop calculation wire size to be acceptable. END OF SECTION FIRE ALARM SEQUENCE OF OPERATION MATRIX FIRE/SMOKE DAMPER FAULT CLOSE FIRE/SMOKE DAMPERS ON A PER FLOOR BASIS SHUTDOWN ASSOCIATED HVAC UNIT SHUNT-TRIP ASSOCIATED POWER ELEVATOR RECALL TO ALTERNATE FLOOR ELEVATOR RECALL TO 1ST FLOOR UNLOCK EXIT DOORS ROLL-DOWN DOORS, SHUTTERS AND SMOKE-GUARD CLOSURE DOOR HOLD/OPEN RELEASE RECORD ALL SYSTEM ACTIVITIES AT PRINTER EQUIPMENT CONTROLLED TRANSMIT SUPERVISORY SIGNAL TO MONITORING COMPANY TRANSMIT TROUBLE SIGNAL TO MONITORING COMPANY TRANSMIT ALARM SIGNAL TO MONITORING COMPANY TRANSMIT SUPERVISORY SIGNAL TO REMOTE ANNUNCIATOR TRANSMIT TROUBLE SIGNAL TO REMOTE ANNUNCIATOR TRANSMIT ALARM SIGNAL TO REMOTE ANNUNCIATOR ACTIVATE AUDIBLE & VISUAL EVACUATION FOR BUILDING NOTIFICATION INDICATE INPUT SIGNAL ON LCD DISPLAY ACTUATE SUPERVISORY SIGNAL AUDIBLE (BUZZER) ACTUATE SUPERVISORY SIGNAL INDICATOR (AMBER LED) ACTUATE TROUBLE SIGNAL AUDIBLE(BUZZER) ACTUATE TROUBLE SIGNAL INDICATOR (AMBER LED) ACTUATE ALARM SIGNAL AUDIBLE (BUZZER) ACTUATE ALARM SIGNAL INDICATOR (RED LED) SYSTEM OUTPUTS FACP ANNUNCIATION SYSTEM INPUTS 120 LED 80 CRI-40W PHILIPS DAYBRITE# 1-SDL-41L-840-4-D4,500 UNIV-DIM OR LITHONIA #RTLX4-40L-MVOLT-EZ1-LP840 OR CORELIGHT # R2-W-L-2-L35-1-D-120-14-SU 6 Fixtures to be mounted with lamps oriented as indicated on drawings. SYSTEM OPERATION INPUT SIGNALS AND OUTPUT FUNCTIONS VOLTS F3 5 All track and low voltage strip lights to be furnished with all necessary feeds, splices, connections, etc.as required for a complete installation. 11 WATTS F2 Bike Sign LED linear graze asymetrical, 15°x15°, multi-volt, IP66. 120 LAM P QTY / TYPE F1 Level 02 walkway AF4 MFR. / CAT. NO. HE WILLIAMS # 75L-4-LED*PH50/835-DMA LED 80CRI/4000K 52 W 5000 LUMENS OR COOPER 4SWLED-LD4-56HL-LWUNIV-L8XXCD2-SVPD2-U OR LITHONIA ZL1F-L48-6000LM-MDD-120-40K80CRI-WH Front of Screen LED surface mounted downlight, 50° beam spread, black finish, 0-10V dimming, IP55. Mounted to horizontal screen structure. 120 TYPE MANUAL PULL STATION AREA SMOKE DETECTOR AREA HEAT DETECTOR ELEVATOR INTERFACE INPUTS: 45 GARAGE THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 STAIR Revision Date LOBBY SMOKE DETECTOR, EXCEPT 1ST FLR LOBBY SMOKE DETECTOR @ 1ST FLR MACHINE ROOM SMOKE DETECTOR ELEVATOR SHAFT SMOKE DETECTOR MACHINE ROOM HEAT DETECTOR DUCT-MTD SMOKE DETECTOR @ HVAC UNIT IN-DUCT DETECTOR @ FSD SURFACE PLENUM SMOKE DETECTOR @ FSD WATERFLOW SWITCH VALVE TAMPER SWITCH POST INDICATING VALVE EMERGENCY GENERATOR MONITORING: C:\Users\jleite\Documents\Center St_jleite.rvt GENERATOR RUNNING GENERATOR TROUBLE LOW FUEL TANK OUTPUT BREAKER OPEN INITIATING CIRCUIT: OPEN WIRE Date Project No. Drawn By Checked By Scale GROUNDED WIRE SHORTED WIRES NOTIFICATION CIRCUIT: OPEN WIRE GROUNDED WIRE SHORTED WIRES SIGNALING LINE CIRCUIT: OPEN WIRE GROUNDED WIRE WIRE TO WIRE SHORT & OPEN WIRE TO WIRE SHORT & GROUND 3/25/2015 7:59:25 AM Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E0.2 LIGHTING FIXTURES AND PANEL SCHEDLULES.DWG Last saved by: PAUL(2016-04-01) Last Plotted: 2016-04-01 ELEVATOR SHAFT HEAT DETECTOR Drawing Title: ELECTRICAL SCHEDULES OPEN & GROUND LOSS OF CARRIER POWER DISCONNECT SUPERVISION Drawing No. FIRE ALARM SYSTEM LOW BATTERY E0.2 BERKELEY, CA 94704 J Oakland Irvine Los Angeles 7 18 S 18 J 17 J J J J J 5 J 10 AF J S CR 6 2D/1V J 8 J 6 Architecture / Engineering / Consulting J T 17 2 A ES RX 15 J S S 6 T 560 - 14th Street Suite 300 Telephone 510 473 0300 T 6 12 J 2D/1V 2D/1V J 2D/1V Consulting Engineers WAP 1 2D/1V T W 2V T S 3 2D/1V 3 J J J 3 ES 1V/1D J 2D 2D/1V 2D J T S 3 6 3 14 2D/1V 2D 2D 2D 13 J J J J J CR A ES CR 8 2D THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 15 J ES J CR 15 Oakland, CA 94612 Fax 510 473 0310 T 2D/1V S 9 E 17 S T 3 16 17 2 J J 6 J CENTER STREET J T S 17 J J J 8 J 17 J Revision Date AF S 10 T 5 J E J J J J 17 8 11 18 18 C:\Users\jleite\Documents\Center St_jleite.rvt # 1 11 2 12 3 4 5 6 7 13 14 Date Project No. Drawn By Checked By Scale 15 16 8 17 9 Drawing Title: 10 3/25/2015 7:59:25 AM Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.1 GROUND LEVEL POWER AND SIGNAL PLAN.DWG Last saved by: PAUL(2016-04-01) Last Plotted: 2016-04-01 project N true N 7 18 GROUND LEVEL POWER AND SIGNAL PLAN Drawing No. E2.1 BERKELEY, CA 94704 5.5 Oakland Irvine Los Angeles Architecture / Engineering / Consulting 6 J S E 1 T 10 UP 560 - 14th Street Suite 300 Telephone 510 473 0300 8 DN Oakland, CA 94612 Fax 510 473 0310 8 8 Consulting Engineers THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 This one 5 A.9 J J 2 3 4 2 J J 3 3 J 3 J J J 3 J J 3 J J 2 3 2 3 J J 2 J J J J 2 3 J 5 J 2 2 J J 2 3 J 2 J 3 2 2 4 J Revision Date 7 7 ST UP ST 7 DN E ST ST 7 9 C:\Users\jleite\Documents\Center St_jleite.rvt # 1 2 10 Date Project No. Drawn By Checked By Scale 3 4 5 6 Drawing Title: 7 3/25/2015 7:59:25 AM Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.2 SECOND LEVEL POWER AND SIGNAL PLAN.DWG Last saved by: PAUL(2016-03-24) Last Plotted: 2016-03-24 6 8 9 SECOND LEVEL POWER AND SIGNAL PLAN Drawing No. E2.2 BERKELEY, CA 94704 Oakland Irvine Los Angeles 7 Architecture / Engineering / Consulting DN 2 J E 6 1 560 - 14th Street Suite 300 Telephone 510 473 0300 4 UP Oakland, CA 94612 Fax 510 473 0310 4 Consulting Engineers THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 2 J J 2 3 2 J J 3 2 J J 3 J J 3 2 2 J J 3 J 3 3 J 3 2 J J J J 3 J J 3 2 J 2 3 2 3 J J J 2 J J 2 Revision 3 Date UP 3 1 E J 5 DN 2 C:\Users\jleite\Documents\Center St_jleite.rvt # 3/25/2015 7:59:25 AM Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.3 THIRD LEVEL POWER AND SIGNAL PLAN.DWG Last saved by: PAUL(2016-03-23) Last Plotted: 2016-03-23 7 1 5 2 6 Date Project No. Drawn By Checked By Scale 3 4 7 Drawing Title: THIRD LEVEL POWER AND SIGNAL PLAN Drawing No. E2.3 BERKELEY, CA 94704 A Oakland Irvine Los Angeles T S DN T Architecture / Engineering / Consulting 2 E J 6 1 560 - 14th Street Suite 300 Telephone 510 473 0300 4 Oakland, CA 94612 Fax 510 473 0310 4 Consulting Engineers THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 Revision Date 3 UP 1 3 E J 5 T T S DN A C:\Users\jleite\Documents\Center St_jleite.rvt # 3/25/2015 7:59:25 AM Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.4 FOURTH LEVEL POWER AND SIGNAL PLAN.DWG Last saved by: PAUL(2016-03-23) Last Plotted: 2016-03-23 2 1 5 2 6 Date Project No. Drawn By Checked By Scale 3 4 Drawing Title: FOURTH LEVEL POWER AND SIGNAL PLAN Drawing No. E2.4 BERKELEY, CA 94704 CONVERSION MANAGEMENT ASSOCIATES, INC. 1620 Montgomery Street Suite 320, San Francisco, CA 94111 415.597.8414 Oakland Irvine Los Angeles Architecture / Engineering / Consulting 2 J E 6 1 560 - 14th Street Suite 300 Telephone 510 473 0300 4 Oakland, CA 94612 Fax 510 473 0310 UP 4 Consulting Engineers THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 Revision Date 3 1 3 E J 5 Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.5 FIFTH LEVEL POWER AND SIGNAL PLAN.DWG Last saved by: LIZ(2016-03-03) Last Plotted: 2016-03-08 2 # 1 5 2 6 Date Project No. Drawn By Checked By Scale 11/19/2015 14877 3 4 PERMIT SET 11/19/2015 Drawing Title: FIFTH LEVEL POWER AND SIGNAL PLAN Drawing No. E2.5 BERKELEY, CA 94704 CONVERSION MANAGEMENT ASSOCIATES, INC. 1620 Montgomery Street Suite 320, San Francisco, CA 94111 415.597.8414 Oakland Irvine Los Angeles DN Architecture / Engineering / Consulting 2 J E 6 1 560 - 14th Street Suite 300 Telephone 510 473 0300 4 Oakland, CA 94612 Fax 510 473 0310 UP 4 Consulting Engineers THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 Revision Date 3 UP 1 3 E J 5 DN Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.6 SIXTH LEVEL POWER AND SIGNAL PLAN.DWG Last saved by: PAUL(2016-03-08) Last Plotted: 2016-03-08 2 # 1 5 2 6 Date Project No. Drawn By Checked By Scale 11/19/2015 14877 3 4 PERMIT SET 11/19/2015 Drawing Title: SIXTH LEVEL POWER AND SIGNAL PLAN Drawing No. E2.6 BERKELEY, CA 94704 CONVERSION MANAGEMENT ASSOCIATES, INC. 1620 Montgomery Street Suite 320, San Francisco, CA 94111 415.597.8414 Oakland Irvine Los Angeles DN Architecture / Engineering / Consulting 2 J E 6 1 560 - 14th Street Suite 300 Telephone 510 473 0300 4 UP Oakland, CA 94612 Fax 510 473 0310 4 Consulting Engineers THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 Revision 3 Date UP 3 1 E J 5 DN Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.7 SEVENTH LEVEL POWER AND SIGNAL PLAN.DWG Last saved by: LIZ(2016-03-03) Last Plotted: 2016-03-08 2 # 1 5 2 6 Date Project No. Drawn By Checked By Scale 11/19/2015 14877 3 4 PERMIT SET 11/19/2015 Drawing Title: SEVENTH LEVEL POWER AND SIGNAL PLAN Drawing No. E2.7 BERKELEY, CA 94704 (2) 2" CONDUIT RISER FOR PHOTOVOLTAIC PANELS Oakland Irvine Los Angeles (2) 2" CONDUIT RISER FOR PHOTOVOLTAIC PANELS 2 1 DN 18 18 J 2 E WP WP 7 1 Architecture / Engineering / Consulting G 6 560 - 14th Street Suite 300 Telephone 510 473 0300 4 Oakland, CA 94612 Fax 510 473 0310 4 7 Consulting Engineers (2) 2" CONDUIT RISER FOR PHOTOVOLTAIC PANELS THE POWER HOUSE 1305 MARINA VILLAGE PARKWAY ALAMEDA, CA. 94501 (510) 769-7600 JOB #14073 (2) 2" CONDUIT RISER FOR PHOTOVOLTAIC PANELS 7 Revision Date (2) 2" CONDUIT RISER FOR PHOTOVOLTAIC PANELS 3 1 3 G (2) 2" CONDUIT RISER FOR PHOTOVOLTAIC PANELS 7 MOUNT ON CANOPY SUPPORT AT +80" AFF, TYP. WP E J 5 43 DN WP WP 43 18 18 C:\Users\jleite\Documents\Center St_jleite.rvt # 3/25/2015 7:59:25 AM Filename: \\TAU\DATA\CADFILES\14073_BERKELEY CENTER STREET GARAGE\CAD\BPS-E2.8-ROOF POWER AND SIGNAL PLAN.DWG Last saved by: PAUL(2016-04-01) Last Plotted: 2016-04-01 project N true N 2 SMART INVERTER TYPE PHOTOVOLTAIC SYSTEM SHALL INCLUDE THE FOLLOWING FEATURES: BASE DESIGN SHALL BE PRICED BASED ON 11,174 SQUARE FEET OF AVAILABLE ROOF TRUSS SPACE. ESTIMATED AT 15W/SF, THIS IS ROUGHLY A 168 KW SYSTEM. GRID CONNECTED, NET-METERING. MUST BE ABLE TO OFFER LOW VOLTAGE RID-THROUGH. BID ALTERNATE DESIGN B2(a) SHALL BE PRICED FOR THE MAXIMUM CAPACITY OF THE ROOF TRUSS AT 21,200 SQUARE FEET . AT 15W/SF, THIS IS ROUGHLY A 318 KW SYSTEM. GRID-CONNECTED, NET METERING. MUST BE ABLE TO RECEIVE ACTIVE AND REACTIVE POWER (P&Q) SET POINTS. SYSTEM MUST BE IN COMPLIANCE WITH IEEE 1547.4 Guide for Design, Operation, and Integration of Distributed Resource Island Systems with Electric Power Systems BID ALTERNATE DESIGN B2 (b) SHALL INCLUDE (FOR BOTH OF THE ABOVE SIZES) A SMART INVERTER PV STORAGE TYPE SYSTEM. FOR BID PURPOSES ONLY, USE A BATTERY SIZED AT 100KWH, BUT EXCLUDE THE BATTERY STORAGE. THE SYSTEM SHALL HAVE THE CAPABILITY OF RUNNING AS A STANDARD GRID-CONNECTED SETUP, AND CONVERT TO UTILIZING STORAGE AT A FUTURE DATE WITH MINIMAL RE-WORK. BID ALTERNATE DESIGN B2 (c) SHALL BE PRICED AS THE DEDUCTIVE COST FOR LIMITING THE PV SYSTEM TO THE BASE DESIGN, AND THE DOWNSIZING THE PV INFRASTRUCTURE TO MATCH. INCLUDE LINE ITEMS FOR THE SWITCHGEAR BUS TO BE REDUCED BY 400 AMPS, THE CIRCUIT BREAKER AT THE MAIN SWITCHBOARD TO BE REDUCED TO 600 AMPS, AND THE RISERS FOR THE PV SYSTEM REDUCED TO CODE MINIMUM. 1 2-WAY COMMUNICATION SYSTEM - PART OF FIRE ALARM/LIFESAFETY SYSTEM. ROUTE 3/4"C.O. TO MAIN CONTROLLER IN ELECTRICAL ROOM #2. 2 12"WX12"HX4"D NEMA 3, SCREW COVER TELECOM J-BOX, WITH 2-2" RISER CONDUITS FROM FLOOR BELOW AND TO FLOOR ABOVE. 3 ROUTE (1) 1" C. TO J-BOX. TERMINATE IN A FLUSH MOUNT 4" SQ. BOX IN CEILING. ROUTE DATA CABLE TO MECHANICAL ROOM IDF ON LEVEL 1. 4 ROUTE (1) 1" C. TO TELECOM J-BOX. TERMINATE IN A FLUSH MOUNT 4" SQ. BOX IN CEILING. ROUTE DATA CABLE TO IT/SVR ROOM IDF ON LEVEL 1. 5 6 WALL MOUNT A E-PHONE ON WALL AND ROUTE (1) 1" C. TO J-BOX. TERMINATE IN A FLUSH MOUNT SINGLE GANG BOX IN WALL AT 18" BELOW E-PHONE. PROVIDE A .75" LIQUID TIGHT CONDUIT FROM OUTLET BOX TO BOTTOM OF E-PHONE. ROUTE TELEPHONE CABLE TO IT/SRV ROOM IDF ON LEVEL 1 AND CROSS CONNECT TO 110 RISER. 7 RISER LOCATION FOR PHOTOVOLTAIC PANEL SYSTEM. PROVIDE (1) 3" SLEEVE TO FLOOR BELOW. SEE PV SYSTEM DRAWINGS FOR FEEDER INFORMATION. ALSO REFER TO PV SYSTEM BID ALTERNATES THIS SHEET. 8 MOUNT RECEPTACLE AT HEIGHT TO BE DETERMINED BY THE ELEVATOR INSTALLER OR INSPECTOR. Date Project No. Drawn By Checked By Scale WALL MOUNT A E-PHONE ON WALL AND ROUTE (1) 1" C. TO J-BOX. TERMINATE IN A FLUSH MOUNT SINGLE GANG BOX IN WALL AT 18" BELOW E-PHONE. PROVIDE A .75" LIQUID TIGHT CONDUIT FROM OUTLET BOX TO BOTTOM OF E-PHONE. ROUTE TELEPHONE CABLE TO MECHANICAL ROOM IDF ON LEVEL 1 AND CROSS CONNECT TO 110 RISER. Drawing Title: ROOF POWER AND SIGNAL PLAN Drawing No. E2.8