412034.E01 5/7 5/7/03 4:51 PM Page E1 Commercial and Die Cast Fittings Conduit Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . E2 Thinwall Conduit Fittings (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E3-E14 Rigid/Intermediate Grade Conduit Fittings . . . . . . . . . . . . . . . . . . . . . E15-E27 Rigid/Aluminum Conduit Bodies, Gaskets and Covers . . . . . . . . . . . . . . . . . E28-E29 Aluminum Conduit Bodies, Gaskets and Covers . . . . . . . . . . . . . . . . . . . . . E30 Flexible Cord and Power Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . E31 Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing . . . . . . . . E32-E33 Liquidtight Fittings. . . . . . . . . . . . . . . . . . . . . . . . . E34 Liquidtight Flexible Metal Conduit Connectors . . . . . . . . . . . . . . . . . . E35-E37 Nonmetallic Sheathed Cable and Flexible Cord Connectors . . . . . . . . . . . . . . . . . E38 Nonmetallic Sheathed Cable Fittings . . . . . . . . . . . . . . . . . . . . . . . E39-E40 Armored Cable/Flexible Metallic Conduit Fittings . . . . . . . . . . . . . . . . . . . . . E41-E46 Cable Straps, Cable Caps . . . . . . . . . . . . . . . . . . E47 Service Entrance Fittings . . . . . . . . . . . . . . . . . . . E48 Grounding Clamps/Connectors . . . . . . . . . . . . . . E49 Gutter Connectors/Cable Protector and Cable Clip . . . . . . . . . . . . . . . . . . . . . . . . . . E50 Beam Clamps for Mounting Pipe or Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E51 Conduit and Pipe Hangers . . . . . . . . . . . . . . . . . . E52 Beam Clamps/Threaded Rod/ Rod Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . E53 E 412034.E01 5/7 5/7/03 4:52 PM Page E2 Conduit Fittings Steel City® Conduit Fittings provide long-lasting service in commercial, industrial and residential construction. Our fittings are manufactured within strict tolerances to maintain consistent performance. Installers can be assured that every fitting with the Steel City name will work every time. So when you select Steel City® Conduit Fittings, that means fewer headaches and call-backs. Steel City® products symbolize the highest quality standards in manufacturing and innovative design, with one of the most complete offerings available. Contact a T&B distributor nearest you to select the right Steel City® product for your requirements. Steel City ® E Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion that does not exceed thickness of EMT. Keeps forcefully inserted conduit from breaking through the opposite side of the coupling while not interfering with the pulling of conductors. Heavy Duty Thick Steel Body/Glands with Continuous Threading • True hexagonal shape. The non-circular design has actual flats for gripping power using hand or tool force. Extra Thick Electroplated Zinc Finish • Assures corrosion resistance while the clear chromate coating gives the fittings their quality shine and luster. Couplings and Connectors Superior Quality and Design • Strict tolerances throughout fitting assures a straight conduit run with no sagging over extreme lengths. • Chamfered entry provides lead-in for conduit insertion. Dependable Pipe Stop • 360° grove traveling the circumference assures that conduit forcefully inserted won't break through to the opposite side of the fitting. Also, it does not exceed thickness of EMT and prevents interference with pulling conductors. Extra Large Head Tri-Drive Set-Screw • Accommodates Phillips, Slotted and Square drives. Enhanced Locknut Construction • Heavy-duty turned sharp teeth, double-threaded. E2 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E3 Thinwall Conduit Fittings (EMT) Here’s How The Steel City Part Number System Works © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 1st Digit – Material 1 = Steel 2 = Die Cast 3 = Combination Steel and Die Cast 4 = Malleable 5 = Plastic 6 = Aluminum 7 = Steel Insulated 8 = Die Cast Insulated 9 = Malleable Insulated 2nd Digit – Method 1 = Compression 2 = Set Screw 3 = Other 3rd/4th Digit Size 1 = d" 2 = f" 3 = 1" 4 = 1b" 5 = 1d" 6 = 2" 7 = 2d" 8 = 3" 9 = 3d" 10 = 4" 11 = 5" 12 = 6" A few examples of the three digit identification system for thinwall fittings are: TK-111 d" steel, compression type coupling TC-714 1b" steel insulated compression type connector TC-822 f" die cast, insulated, set-screw type connector E3 E Steel City ® Easy to identify alphabetical prefixes: BG – Bushings, Grounding BI – Bushings, Insulated BL – Blanks BU – Bushings CB – Clamp Back EK – 3 Piece Coupling GA – Ground Clamp (armored ground wire) GC – Ground Clamp HA – Heavywall Adapter HC – Heavywall Connector HK – Heavywall Coupling HO – Heavywall Offset HS – Heavywall Strap LG – Locknut, Grounding LN – Locknut LT – Liquidtight NC – Nonmetallic Sheathed Cable Connector NS – Nonmetallic Sheathed Cable Strap SH – Service Entrance Fitting SL – Service Ells SR – Sealing Rings LS – Locknut, Sealing TC – Thinwall Connectors TK – Thinwall Couplings TO – Thinwall Offset TS – Thinwall Strap TX – Thinwall to Flexible Metallic Conduit Fitting UC – Utility Connector WA – Washer XC – Armored Cable or Flexible Metallic Conduit Connector XK – Armored Cable or Flexible Metallic Conduit Coupling 412034.E01 5/7 5/7/03 4:52 PM Page E4 Thinwall Conduit Fittings (EMT) New Design ® Set Screw Connectors, Steel – Non-Insulated "A" Cat# TC121A TC122A TC123A TC124A TC125A TC126A TC127A TC128A TC129A TC1210A Steel City ® E • Concrete Tight • Zinc Plated Conduit Size Inner Pack Outer Pack d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 50 50 25 – – – – – – – 500 250 100 25 25 25 10 5 5 5 Set Screw Connectors, Steel – Insulated "A" Cat# TC721A TC722A TC723A TC724A TC725A TC726A TC727A TC728A TC729A TC7210A Conduit Size Inner Pack Outer Pack d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 50 50 25 – – – – – – – 500 250 100 25 25 25 10 5 5 5 U.L. File No. E-16592 New Design ® Set Screw Couplings – Steel "A" Cat# TK121A TK122A TK123A TK124A TK125A TK126A TK127A TK128A TK129A TK1210A • Concrete Tight, when taped • Zinc Plated E4 Conduit Size Inner Pack Outer Pack d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 50 50 25 – – – – – – – 500 250 100 25 25 25 10 5 5 5 U.L. File No. E-16592 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E5 Thinwall Conduit Fittings (EMT) New Design ® Compression Connectors, Steel – Non-Insulated "A" Cat# • 1⁄2" – 4" Concrete Tight • Zinc Plated Inner Pack Outer Pack d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 50 50 25 – – – – – – – 500 250 100 25 25 25 10 5 5 5 E Steel City ® TC111A TC112A TC113A TC114A TC115A TC116A TC117A TC118A TC119A TC1110A Conduit Size Compression Connectors, Steel – Insulated "A" Cat# TC711A TC712A TC713A TC714A TC715A TC716A TC717A TC718A TC719A TC7110A Conduit Size Inner Pack Outer Pack d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 50 50 25 – – – – – – – 500 250 100 25 25 25 10 5 5 5 U.L. File No. E-16592 New Design ® Compression Couplings – Steel "A" Cat# TK111A TK112A TK113A TK114A TK115A TK116A TK117A TK118A TK119A TK1110A • 1⁄2" – 4" Concrete Tight • Zinc Plated Conduit Size Inner Pack Outer Pack d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 50 50 25 – – – – – – – 250 250 100 25 25 25 10 5 5 5 U.L. File No. E-16592 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E5 412034.E01 5/7 5/7/03 4:52 PM Page E6 Thinwall Conduit Fittings (EMT) ® ® EMT LOK Conduit Connector Cat. No. TC-101-SC TC-102-SC TC-701-SC TC-702-SC Steel City ® E • Simple, one-piece installation with no locknuts. • Available in insulated or noninsulated throat. • Screw designed for exceptional pullout resistance. • Captive screw ensures that the screw is intact for installation and resists backing out after installation. • Corrosion-resistant, zinc-chromatic plating. • Concrete tight. • Positive grounding. • Vibration resistant screw design. • UL listed and CSA certified. Description Std. Ctn. d" Uninsulated f" Uninsulated d" Insulated f" Insulated 500 250 500 250 U.L. Listing No. E16592, CSA Listing No. LR-12798 Installation using either slotted or Phillips screwdriver head, 35-in-lb of torque onto the EMT. NOTE: Excessive torque could damage EMT or housing. Additional Commercial Construction Products from Thomas & Betts Steel City ® Steel Boxes, Covers, & Accessories • Notched Ears on Switch Boxes provide clearance for the screws that are used to attach wall plates to GFCI or rocker-type light switches. • Universal Metal Stud Bracket mounts without the use of screws, to the open or closed side of the stud and works on any depth of non-loadbearing metal stud. • Eccentric Knockouts on Square Boxes provide better contact with conduit fitting and locknut to the box, improves grounding path, stronger than f" knockout. • Improved f" Knockout Position on Square Boxes requires less labor to install f" conduit to box. • Raised Ground Screw in Utility Boxes make for quicker surface mounting by eliminating the need to remove the portion of the screw that threads through the back of the box, allows for improved repositioning of grounding conductor. • Preinstalled Screws are Packaged in raised position eliminates extra step of having to back out the screw during cover installation. Steel City ® Underfloor Duct, Floor Boxes, & Poke-Throughs • Steel City conventional underfloor duct offers multi-compartmental duct and junction boxes with builtin tile trim. • Header duct and access hatch designs of cellular underfloor duct system provide convenient wire and cable access, eliminating junction boxes. • Accommodate power, voice, or data with Steel City flush floor boxes, available in cast-iron, steel, and nonmetallic constructions. • Access floor modules blend with any decor and accommodate virtually any raised floor surface. • Steel City poke-through devices allow the interchange of flush, low-profile, and standard service heads without removing the lower core unit. E6 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E7 Thinwall Conduit Fittings (EMT) ® ® Compression Connectors – Die Cast Zinc, Noninsulated A Cat. No. B A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1b" 1X" 1S" 1m" 1g" 2q" 2}" 2g" 2I" 2m" 1 1q" 1v" 1B" 2h" 2w" 3b" 3n" 4k" 4n" 500 250 200 100 40 20 12 12 10 6 TC-211-SC TC-212-SC TC-213-SC TC-214-SC TC-215-SC TC-216-SC TC-217-SC TC-218-SC TC-219-SC TC-2110-SC E U.L. File No. E-16592 – d"-4" CSA File No. LR-12798 – d"-2 ® ® Compression Connectors – Die Cast Zinc, Insulated Cat. No. A B • 1⁄2" – 4" Concrete Tight Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1R" 1v" 1{" 1C" 1O" 2b" 2A" 2O" 2B" 2C" ©" n" 1v" 1B" 2h" 2w" 3b" 3n" 4k" 4n" 500 250 200 100 40 20 12 12 10 6 TC-811-SC TC-812-SC TC-813-SC TC-814-SC TC-815-SC TC-816-SC TC-817-SC TC-818-SC TC-819-SC TC-8110-SC U.L. File No. E-16592 – d"-4" CSA File No. LR-12798 – d"-2 ® ® Compression Couplings – Die Cast Zinc A Cat. No. B • 1⁄2" – 4" Concrete Tight TK-211-SC TK-212-SC TK-213-SC TK-214-SC TK-215-SC TK-216-SC TK-217-SC TK-218-SC TK-219-SC TK-2110-SC Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1d" 1e" 1g" 1m" 2s" 2X" 3$" 3r" 3!" 3i" 1p" 1j" 1}" 2p" 2Q" 2C" 3™" 4d" 5h" 5G" 500 250 200 100 40 20 12 12 10 6 U.L. File No. E-16592 – d"-4" CSA File No. LR-12798 – d"-1b", 2d"-4" ® B Offset Compression Connectors – Die Cast Zinc Cat. No. A TO-211SC c" offset TO-212 f" offset Conduit Size A B Std. Ctn. d" f" 2$" 2.98" 1" 1.16" 200 100 U.L. File No. E-16592 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E7 Steel City ® • 1⁄2" – 4" Concrete Tight Conduit Size 412034.E01 5/7 5/7/03 4:52 PM Page E8 Thinwall Conduit Fittings (EMT) ® ® A Set Screw Connectors – Die Cast Zinc, Noninsulated Cat. No. B E Steel City ® • Concrete Tight, when taped TC-221-SC TC-222-SC TC-223-SC TC-224-SC TC-225-SC TC-226-SC TC-227-SC TC-228-SC TC-229-SC TC-2210-SC A Conduit Size TC-221 Series TC-821 Series B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1q" 1u" 1l" 1n" 2s" 2E" 3i" 3ç" 3M" 3I" 1å" 1E" 1y" 2o" 2c" 2T" 3s" 3M" 3x" 3K" n" 1q" 1N" 1m" 2Y" 2w" 3∫" 4h" 4w" 5h" 500 250 200 100 40 20 12 12 10 6 Noninsulated U.L. File No. E-16592 – d"-2" U.L. File No. E-1275 – 2d"-4" CSA File No. LR-12798 – d"-1", 2d"-4" A Set Screw Connectors – Die Cast Zinc, Insulated Cat. No. B • Concrete Tight, when taped TC-821-SC TC-822-SC TC-823-SC TC-824-SC TC-825-SC TC-826-SC TC-827-SC TC-828-SC TC-829-SC TC-8210-SC A Conduit Size TC-221 Series TC-821 Series B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1q" 1u" 1l" 1n" 2s" 2E" 3i" 3ç" 3M" 3I" 1å" 1E" 1y" 2o" 2c" 2T" 3s" 3M" 3x" 3K" n" 1q" 1N" 1m" 2Y" 2w" 3∫" 4h" 4w" 5h" 500 250 200 100 40 20 12 12 10 6 Insulated U.L. File No. E-16592 – d"-2" U.L. File No. E-1275 – 2d"-4" CSA File No. LR 12798 – d"-2" ® ® Set Screw Couplings – Die Cast Zinc Cat. No. • Concrete Tight, when taped TK-221 TK-222 TK-223 TK-224 TK-225 TK-226 TK-227 TK-228 TK-229 TK-2210 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1E" 1C" 2" 2E" 2B" 3u" 4r" 4W" 4B" 5v" ∂" 1q" 1k" 1B" 2h" 2d" 3∫" 4Y" 4w" 4l" 500 250 200 100 40 20 12 12 10 6 U.L. File No. E-16592 – d"-2" U.L. File No. E-1275 – 2d"-4" CSA File No. LR-12798 – d"-1b", 2d"-4" E8 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E9 Thinwall Conduit Fittings (EMT) B C B C EMT Connectors 90° Angle – Die Cast Zinc Cat. No. A A Trade Size A B C Std. Ctn. d" 1.27 1.15 .45 200 d" f" 1.37 1.86 1.15 .95 .45 .52 200 200 SET SCREW TYPE TC-921 SET SCREW TYPE COMPRESSION TYPE COMPRESSION TYPE TC-911-SC TC-912-SC E Capped Corner Couplings – Die-Cast Zinc Cat. No. TL-291 TL-292 Conduit Size A B Std. Ctn. d" f" 1.81" 2.00" 1.00" 1.25" 100 50 U.L. File No. E-16592 CSA File No. LR-12798 • Concrete Tight, when taped ® ® Set Screw Connectors – Die-Cast Zinc, Offset Cat. No. TO-221 TO-222 TO-223 • Concrete Tight, when taped Offset Conduit Size A B C Std. Ctn. c" f" f" d" f" 1" 2.00" 2.98" 3.15" .90" 1.16" 1.42" .37 .25 .75 100 100 100 U.L. File No. E-16592 CSA File No. LR-18130M57 ® EMT to Box Set Screw Type – Die-Cast Zinc Cat. No. TL-211 TL-212 Conduit Size A B Std. Ctn. d" f" 1.31" 1.47" .93" 1.22" 100 50 U.L. File No. E-1275 ® EMT to EMT Set Screw Type – Die-Cast Zinc Cat. No. TL-201 TL-202-SC TL-203 TL-204 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1.31" 1.60" 1.94" 2.26" 1.10" 1.24" 1.59" 1.97" 100 50 25 25 U.L. File No. E-1275 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E9 Steel City ® ® ® 412034.E01 5/7 5/7/03 4:52 PM Page E10 Thinwall Conduit Fittings (EMT) ® A Combination Set Screw Couplings – Die-Cast Zinc Flexible Metal Conduit to EMT B TX-220 TX-221 TX-222 TX-223 • Concrete Tight, when taped Conduit Size A B Std. Ctn. c" flex to d" EMT d" flex to d" EMT f" flex to f" EMT 1" flex to 1" EMT 1e" 1m" 1O" 2ƒ" d" 1q" 1X" 1e" 500 250 150 150 U.L. File No. E-1275 Steel City ® E Cat. No. ® Combination Set Screw Couplings – Thinwall to Heavywall – Die-Cast Zinc Cat. No. HT-221 HT-222 HT-223 • Concrete Tight, when taped Conduit Size A B Std. Ctn. d" EMT to d" Rigid f" EMT to f" Rigid 1" EMT to 1" Rigid 1.67" 1.98" 2.15" 1.07" 1.29" 1.58" 500 250 100 U.L. File No. E-1275 A B Corner C Corner Combination Compression Couplings – Thinwall to Liquidtight Flexible Metal Conduit – Steel Cat. No. LTT-111 LTT-112 LTT-113 • Steel • Rain Tight • Zinc Plated Conduit Size A B C Std. Ctn. d" EMT to d" Liquidtight f" EMT to f" Liquidtight 1" EMT to 1" Liquidtight 1f" 1f" 1n" n" 1™" 1d" 1a" 1c" 1f" 100 50 25 A B Corner C Corner Combination Compression Couplings – Heavywall to Liquidtight Flexible Metal Conduit – Steel Cat. No. LTH-111 Conduit Size A B C Std. Ctn. d" Rigid to d" Liquidtight 1g" 1a" 1a" 100 • Steel • Rain Tight • Zinc Plated E10 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E11 Thinwall Conduit Fittings (EMT) Combination Couplings – EMT to Flex Compression to Screw-In Type – Die Cast Zinc Cat. No. TX-201 TX-202 Trade Size A B Std. Ctn. d" f" 0.84 0.95 1.10 1.30 500 250 E Steel City ® Combination Couplings – EMT to Flex Set Screw Type – Die Cast Zinc Cat. No. Fig. “2” d"–d" f"–f" Fig. “1” d"–c" B Fig. # Trade Size A-Min A-Max B Std. Ctn. 1 2 2 d" - c" d" - d" f" - f" 0.15 0.60 0.78 0.61 1.00 1.20 1.16 1.71 1.93 250 250 200 TX-210 TX-211 TX-212 One Hole Snap-Straps – Steel Cat. No. A TS-101 TS-102 TS-103 TS-104 TS-105 TS-106 HS-107 HS-108 HS-109 HS-110 • Steel • Zinc Plated Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 0.57" 0.62" 0.75" 0.88" 0.99" 1.10" 1.28" 1.28" 1.28" 1.28" 1.79" 1.96" 2.25" 2.85" 3.16" 3.93" 5.00" 5.55" 6.37" 6.87" 1000 500 500 250 100 50 25 25 10 10 Pipe Spacers for Thinwall or Heavywall – Die Cast Cat. No. B A CB-201 CB-202 CB-203 CB-204 CB-205 CB-206 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. Conduit Size A B Std. Ctn. d" f" 1" 1a" 1d" 2" 2" 2c" 2f" 2c" 3m" 4d" 1" 1h" 1j" 1d" 1e" 2" 1000 500 500 250 100 50 www.tnb.com E11 412034.E01 5/7 5/7/03 4:52 PM Page E12 Thinwall Conduit Fittings (EMT) B Two Hole EMT Straps – Steel A TS-901 TS-902 TS-903 TS-904 TS-905 TS-906 • Steel • Zinc Plated Steel City ® E Cat. No. A Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 0.56" 0.62" 0.68" 0.75" 0.88" 1.00" 2.20" 2.67" 2.97" 3.67" 4.22" 4.91" 250 200 100 50 200 25 Nail Strap – Steel Cat. No. B N-101-SC N-102-SC N-103-SC Rigid/MC Size EMT Size Flex Size A B Std. Ctn. – d" f" d" f" 1" c" d" – 1n" 2i" 2c" 1Z" 1w" 1v" 1000 1000 1000 • Stamped Steel • Zinc Plated EMT Connectors – Two Piece Type – Die Cast Zinc Cat. No. TC-201-SC Trade Size A B Std. Ctn. d" 0.68 1.05 1000 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2v" 2v" 2v" 2v" 2v" 1E" 1I" 1O" 2M" 3o" 100 100 100 100 100 UL File No. E16592 EMT Connector Space Caps – Plastic Cat. No. B A BT-501 BT-502 BT-503 BT-504 BT-505 Space Cap E12 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E13 Thinwall Conduit Fittings (EMT) ® Aluminum Conduit Bodies, Covers and Gaskets – LR Style Cat. No. TYPE BLR A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2 2j 2d 3c 3c 3n 5d 5d 6d 6d 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. ® Aluminum Conduit Bodies, Covers and Gaskets – LL Style Cat. No. TYPE BLL BLL-1 BLL-2 BLL-3 BLL-4 BLL-5 BLL-6 BLL-7* BLL-8* BLL-9* BLL-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2 2j 2d 3c 3c 3n 5d 5d 6d 6d 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. ® Aluminum Conduit Bodies, Covers and Gaskets – C Style Cat. No. TYPE BC BC-1-RD BC-2-RD BC-3 BC-4 BC-5 BC-6 BC-7* BC-8* BC-9* BC-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 1Q 1w 1f 2d 2d 3a 4d 4d 5d 5d 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. ® Aluminum Conduit Bodies, Covers and Gaskets – LB Style Cat. No. TYPE BLB BLB-1 BLB-2 BLB-3 BLB-4 BLB-5 BLB-6 BLB-7* BLB-8* BLB-9* BLB-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2h 2k 2f 3l 3m 4d 5b 5g 6n 6n 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E13 E Steel City ® BLR-1 BLR-2 BLR-3 BLR-4 BLR-5 BLR-6 BLR-7* BLR-8* BLR-9* BLR-10* Trade Size 412034.E01 5/7 5/7/03 4:52 PM Page E14 Thinwall Conduit Fittings (EMT) ® Aluminum Conduit Bodies, Covers and Gaskets – T Style Cat. No. TYPE BT Steel City ® E BT-1 BT-2 BT-3 BT-4 BT-5 BT-6 BT-7* BT-8* BT-9* BT-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2h 2X 2e 3w 3w 4 5A 5A 6m 6m 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. Aluminum Conduit Bodies, Covers and Gaskets – LR Style Cat. No. TYPE BLRL BLRL-1 BLRL-2 BLRL-3 BLRL-4 BLRL-5 BLRL-6 Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 3g 4e 5c 7b 7b 9d 2 2j 2d 3c 3c 3n 50 50 25 10 10 5 * Shipped with cover. Price includes cost of cover and body. Aluminum Covers with Stainless Steel Screws • Stamped aluminum (1⁄2" thru 2" sizes) or die cast aluminum (21⁄2" thru 4" sizes). • Steel zinc plated screws. Cat. No. Conduit Size Std. Ctn. CV-1 CV-2 CV-3 CV-4 CV-5 CV-6 CV-7 d" f" 1" 1b" - 1d" 2" 2d" - 3" 3d" - 4" 250 250 250 50 25 5 5 SCV-1 SCV-2 SCV-3 SCV-4 SCV-5 d" f" 1" 1b" - 1d" 2" 250 250 250 250 100 Gaskets – Composition Fiber Gasket GKV-1 GKV-2 GKV-3 GKV-4 GKV-5 GKV-6 GKV-7 Conduit Size Std. Ctn. d" f" 1" 1b" - 1d" 2" 2d" - 3" 3d" - 4" 100 50 25 25 25 5 5 Gaskets – Neoprene Neoprene Gasket • Fiber or neoprene material E14 Cat. No. Cat. No. GKN-1 GKN-2 GKN-3 GKN-4 GKN-5 GKN-6 GKN-7 Conduit Size Std. Ctn. d" f" 1" 1b" - 1d" 2" 2d" - 3" 3d" - 4" 100 50 25 25 25 5 5 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E15 Rigid/Intermediate Grade Conduit Fittings Snap in Blanks Cat. No. BL-111 BL-112 BL-113 BL-114 BL-115 BL-116 • Steel • Zinc Plated Conduit Size Diameter Std. Ctn. d" f" 1b" 1" 1d" 2" 1Z" 1b" 1d" 1m" 2r" 2W" 1000 1000 1000 500 500 250 Box Spacer – Die-Cast Zinc (b" space) B Cat. No. BS-201 A Conduit Size A B Std. Ctn. d" 1a" u" 500 U.L. File No. E-1275 ® Threadless Compression Connectors Cat. No. • 1⁄2"-21⁄2" – Steel • 3"-4" – Malleable Iron/Zinc plated HC-401 HC-402 HC-403 HC-404 HC-405 HC-406 HC-407 HC-408 HC-409 HC-410 Conduit Size Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 300 150 90 60 30 12 12 6 6 6 Suggested use – rigid conduit only. U.L. File No. E-1275 d" thru 1b" ® Threadless Compression Couplings Cat. No. • 1⁄2"-21⁄2" – Steel • 3"-4" – Malleable Iron/Zinc plated HK-401 HK-402 HK-403 HK-404 HK-405 HK-406 HK-407 HK-408 HK-409 HK-410 Conduit Size Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 300 150 90 60 30 6 6 4 4 4 Suggested use – rigid conduit only. U.L. File No. E-1275 d" thru 1b" © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E15 Steel City ® ® E 412034.E01 5/7 5/7/03 4:52 PM Page E16 Rigid/Intermediate Grade Conduit Fittings ® Set Screw Connectors B Cat. No. A • Steel (concrete tight), when taped • Zinc plated Steel City ® E HC-101 HC-102 HC-103 HC-104 HC-105 HC-106 HC-107 HC-108 HC-109 HC-110 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1a" 1c" e" 2" 2d" 2f" 3u" 4o" 4l" 5p" 1a" 1d" 1m" 2" 2c" 2c" 3j" 3k" 3m" 4p" 100 50 50 25 25 20 10 5 5 5 One Set Screw or Two Two set screws starting at 2" Trade Size Suggested use – rigid conduit only U.L. File No. E-1275 d" thru 1b" ® Set Screw Connectors – Insulated B Cat. No. HC-701 HC-702 HC-703 HC-704 HC-705 HC-706 HC-707 HC-708 A • Steel (concrete tight), when taped • Zinc plated Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 1a" 1c" e" 2" 2d" 2f" 3u" 4o" 1a" 1d" 1m" 2" 2c" 2c" 3j" 3k" 100 50 25 25 25 20 10 5 One Set Screw or Two Two set screws starting at 2" Trade Size Suggested use – rigid conduit only U.L. File No. E-1275 d" thru 1b" ® B Set Screw Couplings Cat. No. A • Steel (concrete tight), when taped • Zinc plated HK-101 HK-102 HK-103 HK-104 HK-105 HK-106 HK-107 HK-108 HK-109 HK-110 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1a" 1c" 1e" 2" 2b" 2f" 3k" 4h" 4l" 5h" 2u" 2w" 2W" 2A" 3™" 3u" 3C" 4q" 4g" 5c" 100 50 25 25 25 20 10 5 5 5 Two set screws starting at 2". U.L. File No. E-1275 E16 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E17 Rigid/Intermediate Grade Conduit Fittings Rigid Connectors – Set Screw Type – Die Cast Zinc Cat. No. Conduit Size A B Std. Ctn. d" f" 1" 1.34 1.44 1.54 0.39 0.45 0.49 250 250 100 d" f" 1" 1.34 1.44 1.54 0.39 0.45 0.49 250 250 100 HC-201 HC-202 HC-203 WITH INSULATED THROAT HC-801 HC-802 HC-803 Steel City ® Rigid Connector Rigid Couplings – Set Screw Type – Die Cast Zinc Cat. No. HK-201 HK-202 HK-203 Trade Size A B Std. Ctn. d" f" 1" 1.77 2.06 2.29 1.09 1.34 1.61 250 250 100 Rigid Coupling ® 90° Short Radius Elbows – Die Cast Zinc Cat. No. HL-201-SC HL-202-SC Dimensions (in.) Size (in.) A B Shf. Ctn./ Ship Qty. d" f" .98 1.17 .96 1.04 50/500 25/250 USE: To join rigid or IMC conduit at right angles where lack of room prevents using a standard sweep elbow, or to terminate a run of rigid or IMC conduit at a box. UL Listing E37148 Three Piece Couplings Cat. No. A B • 1⁄2"-21⁄2" – Steel • 21⁄2"-6" – Malleable Iron • Zinc plated Conduit Size EK-401 EK-402 EK-403 EK-404 EK-405 EK-406 EK-407 EK-408 EK-409 EK-410 EK-411 EK-412 d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 5" 6" Dimensions (in.) A (Assembled) 1h" 1a" 1c" 1y" 1g" 2" 2d" 3c" 3e" 3C" 4j" 4l" B Shf. Ctn./ Ship Qty. 1a" 1X" 1e" 2q" 2z" 3E" 3S" 4z" 5q" 5C" 7" 8a" 100 50 25 25 25 20 10 6 5 5 1 1 U.L. File No. E-1275 d" thru 4" © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E E17 412034.E01 5/7 5/7/03 4:52 PM Page E18 Rigid/Intermediate Grade Conduit Fittings Rigid Couplings – Three Piece Type – Die Cast Zinc Cat. No. EK-201 EK-202 Trade Size A B Std. Ctn. d" f" 1.39 1.53 1.31 1.58 100 50 ® E Pull Corner Elbows – Die Cast Zinc Steel City ® Cat. No. HL-601 HL-602 HL-603 HL-604 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1.31" 1.60" 1.95" 2.26" 1.10" 1.24" 1.59" 1.97" 100 50 25 30 U.L. File No. E-1275 ® Rigid to Box with Gasket – Die-Cast Zinc Cat. No. HL-611 HL-612 Conduit Size A B Std. Ctn. d" f" 1.31" 1.47" 1.09 1.29" 100 50 U.L. File No. E-1275 The T&B Hub Zinc Die Cast with Insulated Throat* H050-SC Series Hub • The T&B Hub with sealing ring will not fall out. • Provides superior sealing for exceptional watertight performance. E18 Cat. No. Hub Size Std. Ctn. H050-SC H075-SC H100-SC H125-SC H150-SC H200-SC H250-SC H300-SC H350-SC H400-SC H500-SC H600-SC d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 5" 6" 100 100 25 25 10 5 5 2 2 1 1 1 *Available in Nickel-Chrome plating. Consult customer service for price and delivery. *Available with PVC coating. Consult customer service for price and delivery. © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E19 Rigid/Intermediate Grade Conduit Fittings Conduit Nipples – Iron/Zinc Plated A Cat. No. B A B Std. Ctn. c" d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 5" 6" l" W" m" g" 1a" 1a" 1k" 1b" 1d" 1f" – – – W" n" 1r" 1k 1f" 2h" 2l" 3" 3g" 4c" – – – 500 500 200 100 100 50 50 20 10 5 5 1 1 U.L. File No. E-1275 c"-3d" Conduit Nipples – Insulated Iron/Zinc Plated A B Cat. No. HA-901 HA-902 HA-903 HA-904 HA-905 HA-906 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" W" m" g" 1a" 1a" 1k n" 1r" 1k" 1f" 2h" 2l" 500 200 100 100 50 50 ® Conduit Nipples – Die Cast Zinc – Noninsulated Cat. No. HA-201 HA-202 HA-203 HA-204 HA-205 HA-206 HA-207 HA-208 HA-209 HA-210 Conduit Size A B Std. Ctn. d" f" 1" 1b" d" 2" 2d" 3" 3d" 4" 0.98" 1.18" 1.50" 1.75" 2.11" 2.61" 3.13" 3.90" 4.20" 4.79" 0.59" 0.70" 0.80" 1.06" 1.01" 1.20" 1.49" 1.65" 1.68" 1.73" 1000 500 250 250 100 40 40 40 40 20 U.L. File No. E-1275 d" – 2” ® Conduit Nipples – Die Cast Zinc – Insulated Cat. No. HA-801 HA-802 HA-803 HA-804 HA-805 HA-806 HA-807 HA-808 HA-809 HA-810 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 0.98" 1.18" 1.50" 1.75" 2.11" 2.61" 3.13" 3.90" 4.20" 4.79" 0.59" 0.70" 0.80" 1.06" 1.01" 1.20" 1.49" 1.65" 1.68" 1.73" 1000 500 250 250 100 40 25 10 10 10 U.L. File No. E-1275 d" & f“ only © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E19 E Steel City ® 841-TB HA-401 HA-402 HA-403 HA-404 HA-405 HA-406 HA-407 HA-408 HA-409 HA-410 HA-411 HA-412 Conduit Size 412034.E01 5/7 5/7/03 4:52 PM Page E20 Rigid/Intermediate Grade Conduit Fittings ® Conduit Nipples – Die Cast Zinc 1" Long Cat. No. A HA-211 HA-212 HA-213 B Conduit Size A B Std. Ctn. d" f" 1" 1" 1" 1" n" 1i" 1k" 1000 500 250 U.L. File No. E-1275 d" & f“ only E Steel City ® ® Offset Nipples – Die Cast Zinc A Cat. No. f" B HO-221 HO-222 HO-223 HO-224 HO-225 HO-226 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2.60" 2.62" 2.68" 2.85" 2.88" 3.19" 1.00" 1.32" 1.51" 1.85" 2.08" 2.71" 100 100 100 50 50 20 f offset. U.L. File No. E-1275 ® Locknuts – Steel/Zinc Plated B A Cat. No. Dimensions (in.) A (min.) B (max.) Conduit Size LN-100-SC LN-101-SC LN-102 LN-103 LN-104 LN-105 LN-106 LN-107 LN-108 LN-109 LN-110 LN-111 LN-112 – 0.125" 0.140" 0.170" 0.170" 0.170" 0.187" 0.375" 0.375" 0.438" 0.438" 0.500" 0.561" c" d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 5" 6" – 1.140" 1.420" 1.770" 2.281" 2.598" 3.175" 3.562" 4.250" 4.803" 5.402" 6.674" 7.934" Std. Ctn. 1000 1000 1000 500 200 100 50 30 25 25 25 10 10 U.L. File No. E-1275 Thin Construction Locknuts–Steel/Zinc Plated Cat. No. SPLN-107 SPLN-108 SPLN-109 SPLN-110 Conduit Size Unit Qty. Std. Ctn. 2d" 3" 3d" 4" 30 25 25 25 30 25 25 25 *Not U.L. Listed E20 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E21 Rigid/Intermediate Grade Conduit Fittings ® ® B Locknuts – Die Cast Zinc A Cat. No. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" Dimensions (in.) A (min.) B (max.) 0.125" 0.140" 0.170" 0.170" 0.170" 0.187" 0.375" 0.375" 0.438" 0.438" Std. Ctn. 1.140" 1.420" 1.770" 2.281" 2.598" 3.175" 3.562" 4.250" 4.803" 5.402" 2000 1000 1000 500 500 200 100 100 40 40 E Steel City ® LN-201 LN-202 LN-203 LN-204 LN-205 LN-206 LN-207 LN-208 LN-209 LN-210 Conduit Size CSA File No. LR-12798 U.L. File No. E-1275 ® ® Locknuts–Nonmetallic Cat. No. A LN-501 LN-502 LN-503 Trade Size “A” Dia. “B” Thd. Std. Ctn. d" f" 1" 1.3 1.4 1.7 d-14 f-14 1-11d 100 100 50 Material: Nylon 6/6 Color: Gray ® B Sealing Locknuts – Steel/Zinc Plated A Cat. No. LS-101 LS-102 LS-103 LS-104 LS-105 LS-106 LS-107 LS-108 LS-109 LS-110 Conduit Size d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" Dimensions (in.) A (min.) B (max.) 0.26" 0.27" 0.28" 0.32" 0.32" 0.32" 0.32" 0.32" 0.32" 0.32" 1.12" 1.37" 1.75" 2.06" 2.37" 2.87" 3.43" 4.12" 4.62" 5.18" Std. Ctn. 1000 1000 500 200 100 50 50 50 50 25 U.L. File No. E-1275 ® Grounding Locknuts – Malleable Iron/Zinc Plated B A Cat. No. LG-401 LG-402 LG-403 LG-404 LG-405 LG-406 LG-407 LG-408 LG-409 LG-410 Conduit Size d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" Dimensions (in.) A (min.) B (max.) 0.125" 0.140" 0.170" 0.170" 0.170" 0.187" 0.375" 0.375" 0.438" 0.438" 1.140" 1.420" 1.770" 2.281" 2.598" 3.175" 3.562" 4.250" 4.803" 5.402" Std. Ctn. 100 100 50 50 50 25 10 10 50 5 U.L. File No. E-1275 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E21 412034.E01 5/7 5/7/03 4:52 PM Page E22 Rigid/Intermediate Grade Conduit Fittings Conduit Bushings Die Cast Zinc – Insulated Metallic Cat. No. A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1.06 1.31 1.59 1.96 2.18 2.68 3.25 3.87 4.37 5.00 0.43 0.43 0.48 0.56 0.60 0.56 0.90 0.85 0.93 0.93 1000 1000 500 250 250 250 50 25 25 10 BU-801 BU-802 BU-803 BU-804 BU-805 BU-806 BU-807 BU-808 BU-809 BU-810 E Steel City ® Conduit Size • 105°C thermoplastic liners. • Heavy reinforced ribs. Conduit Bushings Die Cast Zinc – Heavy Reinforced Ribs Cat. No. BU-201 BU-202 BU-203 BU-204 BU-205 BU-206 BU-207 BU-208 BU-209 BU-210 Conduit Size d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" Dimensions (in.) A (min.) B (max.) 1.05 1.32 1.58 1.94 2.20 2.69 3.23 3.84 4.35 5.02 0.37 0.37 0.47 0.50 0.52 0.52 0.85 0.85 0.85 0.85 Std. Ctn. 1000 1000 500 250 250 250 50 25 25 10 ® Insulated Bushings – Thermoplastic A B Cat. No. Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 5" 6" u" u" l" l" l" e" z" I" f" A" 1" 1" 1h" 1∫" 1l" 1C" 2i" 2W" 3i" 3B" 4R" 4B" 6j" 7k" 400 400 200 100 100 60 20 20 5 5 5 5 BU-501 BU-502 BU-503 BU-504 BU-505 BU-506 BU-507 BU-508 BU-509 BU-510 BU-511 BU-512 U.L. File No. E-1275 d"-4" only Rated 105°C E22 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E23 Rigid/Intermediate Grade Conduit Fittings ® Bushings – Iron/Zinc Plated B Cat. No. A A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 5" 1o" 1b" 1l" 1n" 2$" 2}" 3i" 3e" 4h" 4y" 4y" k" k" d" w" l" l" x" A" B" n" n" 1000 1000 500 200 100 50 30 25 25 25 10 U.L. File No. E-1275 Insulated Bushings – Iron/Zinc Plated B A Cat. No. BI-901 BI-902 BI-903 BI-904 BI-905 BI-906 BI-907 BI-908 BI-909 BI-910 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 1o" 1b" 1l" 1n" 2$" 2}" 3r" 3B" 4k" 4O" d" d" l" x" e" e" I" I" g" 2s" 1000 1000 500 200 100 50 30 25 25 25 Grounding Bushings Die Cast Zinc – Insulated Metallic – With Aluminum Lay in Type Lug Cat. No. • 105°C Thermoplastic liners. • Heavy reinforced ribs. BG-201 BG-202 BG-203 BG-204A BG-204 BG-205A BG-205 BG-206A BG-206 BG-207 BG-207A BG-208 BG-208A BG-209 BG-209A BG-210 BG-210A © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. Trade Size d" f" 1" 1b" 1b" 1d" 1d" 1" 2" 2d" 2d" 3" 3" 3d" 3d" 4" 4" www.tnb.com Grounding Lug Wire size min. max 14 14 14 14 8 11 8 14 8 8 6 8 6 8 6 8 6 4 4 4 4 1/0 4 1/0 4 1/0 1/0 250 MCM 1/0 250 MCM 1/0 250 MCM 1/0 250 MCM Std. Ctn. 500 500 250 200 200 100 50 100 50 50 50 50 50 10 10 10 10 E23 E Steel City ® BU-401 BU-402 BU-403 BU-404 BU-405 BU-406 BU-407 BU-408 BU-409 BU-410 BU-411 Conduit Size 412034.E01 5/7 5/7/03 4:52 PM Page E24 Rigid/Intermediate Grade Conduit Fittings ® Insulated Grounding Bushings – Malleable Iron/Zinc Plated Cat. No. Conduit Size BG-801 BG-802 BG-803 BG-804 BG-805 BG-806 BG-807 BG-808 BG-809 BG-810 Steel City ® E Grounding Lug Wire Capacity d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" #14-#4 CU or #12-#4 AL #14-1/0 CU or #12-1/0 AL #6-250 MCM CU or AL A B Std. Ctn. 1o" 1b" 1l" 1n" 2$" 2}" 3i" 3e" 4h" 4y" d" d" l" x" e" e" I" I" g" 2s" 500 500 250 150 150 100 60 30 30 30 U.L. File No. E-19851 d"-2" Iron 2b"-4" Die Cast Zinc ® Grounding Bushings Die Cast Zinc – Insulated Metallic With Aluminum Lug Cat. No. • For copper or aluminum bare ground wire. • 105°C thermoplastic liners. • Heavy reinforced ribs. Trade Size BG-801A BG-802A BG-803A BG-804A BG- 805A BG-806A BG-807A BG-808A BG-809A BG-810A BG-810B d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 4" Grounding Lug Wire size min. max 14 14 14 14 14 14 14 14 14 14 6 6 6 6 2 2 2 2/0 2/0 2/0 2/0 250 MCM Std. Ctn. 500 500 250 200 100 100 50 50 10 10 10 U.L. File No. E-19851 ® B Reducing Bushings A • RB-121 thru RB-165 – Steel. • RB-175 thru RB-187 – Malleable Iron (concrete tight)/ Zinc Plated. Cat. No. Conduit Size A B Std. Ctn. RB-121 RB-131 RB-132 RB-141 RB-142 RB-143 RB-151 RB-152 RB-153 RB-154 RB-161 RB-162 RB-163 RB-164 RB-165 RB-175 RB-176 RB-186 RB-187 f"-d" 1"-d" 1"-f" 1b"-d" 1b"-f" 1b"-1" 1d"-d" 1d"-f" 1d"-1" 1d"-1b" 2"-d" 2"-f" 2"-1" 2"-1b" 2"-1d" 2d"-1d" 2d"-2" 3"-2" 3"-2d" l" e" e" W" W" W" z" z" z" z" B" B" B" B" B" g" g" C" C" g" 1a" 1a" 1k" 1k" 1k" 1W" 1W" 1W" 1W" 2p" 2p" 2p" 2p" 2p" 2m" 2m" 2k" 2k" 100 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 25 U.L. File No. E-1275 E24 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E25 Rigid/Intermediate Grade Conduit Fittings Reducers and Enlargers – Malleable Iron/Zinc Plated A B Cat. No. RB-421 RB-432 RB-443 Conduit Size A B Std. Ctn. f"-d" d"-f" 1"-f" e" 1 L" 1i" 1i" 1i" 100 100 50 B U.L. File No. E-1275 E A B C Reducing Washers – Steel/Zinc Plated Cat. No. Conduit Size A Diameter B C Std. Ctn. WA-110 WA-121 WA-131 WA-132 WA-141 WA-142 WA-143 WA-151 WA-152 WA-153 WA-154 WA-161 WA-162 WA-163 WA-164 WA-165 WA-171 WA-172 WA-173 WA-174 WA-175 WA-176 WA-181 WA-182 WA-183 WA-184 WA-185 WA-186 WA-187 d"-c" f"-d" 1"-d" 1"-f" 1b"-d" 1b"-f" 1b"-1" 1d"-d" 1d"-f" 1d"-1" 1d"-1b" 2"-d" 2"-f" 2"-1" 2"-1b" 2"-1d" 2d"-d" 2d"-f" 2d"-1" 2d"-1b" 2d"-1d" 2d"-2" 3"-d" 3"-f" 3"-1" 3"-1b" 3"-1d" 3"-2" 3"-2d" 1i" 1d" 1f" 1f" 2i" 2i" 2i" 2e" 2e" 2e" 2e" 3b" 3b" 3b" 3b" 3b" 3b" 3b" 3b" 3b" 3b" 3b" 4d" 4d" 4d" 4d" 4d" 4d" 4d" W" g" g" 1p" g" 1p" 1R" g" 1p" 1R" 1z" g" 1p" 1R" 1z" 1O" g" 1p" 1R" 1z" 1O" 2k" g" 1z" 1R" 1z" 1O" 2k" 2j" B" 1h" 1j" 1j" 1W" 1W" 1W" 1g" 1g" 1g" 1g" 2c" 2c" 2c" 2c" 2c" 2g" 2g" 2g" 2g" 2g" 2g" 3d" 3d" 3d" 3d" 3d" 3d" 3d" 500 500 500 500 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 WA-121 thru WA-165 CSA listed. © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E25 Steel City ® ® 412034.E01 5/7 5/7/03 4:52 PM Page E26 Rigid/Intermediate Grade Conduit Fittings One Hole Straps – Steel/Zinc Plated Cat. No. Screw Size Conduit Size A B Std. Ctn. 10 b b b j c c k d d d c" d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" f" 1" 1" 1" 1" 1i" 1i" 1b" 1c" 1c" 1c" 1I" 1n" 2Z" 2u" 3p" 3u" 3B" 5h" 5g 6b" 6g" 1000 500 500 250 100 100 100 25 25 10 10 HS-100-SC HS-101 HS-102 HS-103 HS-104 HS-105 HS-106 HS-107 HS-108 HS-109 HS-110 Steel City ® E Pipe Straps – Malleable Iron/Zinc Plated Cat. No. Screw Size Conduit Size A B Std. Ctn. 10 b b b j c d e e e e e c" d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 5" 1W" 2D" 2k" 2g" 3j" 3f" 4x" 5W" 6g" 7z" 8l" 10s" w" e" m" n" 1o" 1a" 1j" 1e" 1g" 2a" 2c" 2e" 500 500 500 100 100 50 25 25 25 10 10 5 HS-400 HS-401 HS-402 HS-403 HS-404-SC HS-405 HS-406 HS-407 HS-408 HS-409 HS-410 HS-411 ® Two Hole Strap – Steel/Zinc Plated Cat. No. HS-901 HS-902 HS-903 HS-904 HS-905 HS-906 HS-907 HS-908 HS-909 HS-910 Screw Size Conduit Size A B C Std. Ctn. 8 10 b b b b b d b b d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" f" f" f" f" f" f" 1" 1" 1" 1" 2k" 2W" 3k" 3B" 4h" 4k" 5a" 6i" 7i" 8W" i" i" i" i" i" i" b" b" b" b" 1200 900 600 450 50 150 150 60 60 60 CSA Certified Nail Strap – Stamped Steel/Zinc Plated A Cat. No. B E26 N-101-SC N-102-SC N-103-SC Rigid/MC Size EMT Size Flex Size A B Std. Ctn. – d" f" d" f" 1" c" d" – 2q" 2j" 2c" 1Z" 1r" 1v" 1000 1000 1000 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E27 Rigid/Intermediate Grade Conduit Fittings A Flange Plates – Malleable Iron/Zinc Plated Cat. No. B j Bolt Hole CB-201 CB-202 CB-203 CB-204 CB-205 CB-206 B Std. Ctn. d" f" 1" 1b" 1d" 2" 3" 3c" 3e" 4" 4c" 4g" .625 .656 .765 .875 .937 .843 50 50 50 25 25 25 Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2" 2c" 2f" 3c" 3m" 4d" 1" 1h" 1j" 1d" 1e" 2" 1000 500 500 250 100 50 Rigid/Intermediate Space Caps – Plastic Cat. No. A Depth B Pipe Spacers for Rigid/Intermediate or Thinwall – Die Cast Zinc Cat. No. A Dia. A BR-501 BR-502 BR-503 BR-504 BR-505 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. Conduit Size A B Std. Ctn. d" f" 1" 1b" 1d" 2v" 2v" 2v" 2v" 2v" 1y" 1U" 2a" 2V" 3$" 100 100 100 100 100 www.tnb.com E27 E Steel City ® B FP-401 FP-402 FP-403 FP-404 FP-405 FP-406 Conduit Size 412034.E01 5/7 5/7/03 4:52 PM Page E28 Rigid/Aluminum Conduit Bodies, Gaskets and Covers ® Conduit Bodies, Covers and Gaskets – LR Style Cat. No. TYPE ALR Steel City ® E • Die cast copper free aluminum construction. • Provide access for pulling, splicing, and maintenance. • For rigid conduit/IMC applications. • U.L. Listed. • Fittings, covers and gaskets are interchangeable with those produced by other leading manufacturers. • Finish: Powder Coated Urethane. ALR-1 ALR-2 ALR-3 ALR-4 ALR-5 ALR-6 ALR-7* ALR-8* ALR-9* ALR-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2 2j 2d 3c 3c 3n 5d 5d 6d 6d 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. ® Conduit Bodies, Covers and Gaskets – LL Style Cat. No. TYPE ALL • Die cast copper free aluminum construction. • Provide access for pulling, splicing, and maintenance. • For rigid conduit/IMC applications. • U.L. Listed. • Fittings, covers and gaskets are interchangeable with those produced by other leading manufacturers. • Finish: Powder Coated Urethane. ALL-1 ALL-2 ALL-3 ALL-4 ALL-5 ALL-6 ALL-7* ALL-8* ALL-9* ALL-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2 2j 2d 3c 3c 3n 5d 5d 6d 6d 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. ® Conduit Bodies, Covers and Gaskets – C Style Cat. No. TYPE AC AC-1 AC-2 AC-3 AC-4 AC-5 AC-6 AC-7* AC-8* AC-9* AC-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 1Q 1w 1f 2d 2d 3a 4d 4d 5d 5d 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. E28 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E29 Rigid/Aluminum Conduit Bodies, Gaskets and Covers ® Conduit Bodies, Covers and Gaskets – LB Style Cat. No. TYPE ALB A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2h 2k 2f 3l 3m 4d 5b 5g 6n 6n 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. ® Conduit Bodies, Covers and Gaskets – C Style Cat. No. TYPE AT AT-1 AT-2 AT-3 AT-4 AT-5 AT-6 AT-7* AT-8* AT-9* AT-10* Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 3g 4e 5c 7b 7b 9d 12b 12b 15 15 2h 2X 2e 3w 3w 4 5A 5A 6m 6m 50 50 25 10 10 5 1 1 1 1 * Shipped with cover. Price includes cost of cover and body. Conduit Bodies, Covers and Gaskets – LR Style Cat. No. TYPE ALRL ALRL-1 ALRL-2 ALRL-3 ALRL-4 ALRL-5 ALRL-6 Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 3g 4e 5c 7b 7b 9d 2 2j 2d 3c 3c 3n 50 50 25 10 10 5 * Shipped with cover. Price includes cost of cover and body. © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E29 E Steel City ® ALB-1 ALB-2 ALB-3 ALB-4 ALB-5 ALB-6 ALB-7* ALB-8* ALB-9* ALB-10* Trade Size 412034.E01 5/7 5/7/03 4:52 PM Page E30 Aluminum Conduit Bodies, Gaskets and Covers Aluminum covers with Stainless Steel Screws Cat. No. • Stamped aluminum (1⁄2" thru 2" sizes) or die cast aluminum (21⁄2" thru 4" sizes). • Steel zinc plated screws. Steel City ® E Conduit Size Std. Ctn. CV-1 CV-2 CV-3 CV-4 CV-5 CV-6 CV-7 d" f" 1" 1b" - 1d" 2" 2d" - 3" 3d" - 4" 250 250 250 50 25 5 5 SCV-1 SCV-2 SCV-3 SCV-4 SCV-5 d" f" 1" 1b" - 1d" 2" 250 250 250 250 100 Conduit Size Std. Ctn. d" f" 1" 1b" - 1d" 2" 2d" - 3" 3d" - 4" 100 50 25 25 25 5 5 Conduit Size Std. Ctn. d" f" 1" 1b" - 1d" 2" 2d" - 3" 3d" - 4" 100 50 25 25 25 5 5 Gaskets – Composition Cat. No. Fiber Gasket GKV-1 GKV-2 GKV-3 GKV-4 GKV-5 GKV-6 GKV-7 Gaskets – Neoprene Neoprene Gasket • Fiber or neoprene material E30 Cat. No. GKN-1 GKN-2 GKN-3 GKN-4 GKN-5 GKN-6 GKN-7 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E31 Flexible Cord & Power Cable Connectors The BLACK BEAUTY ™ Nonmetallic Liquidtight Strain Relief Connectors • Non metallic construction provides corrosion resistance. • Weathers stabilized nylon rated at –34°C to +105°C temperature. • Installs on cord by hand. • Achieves maximum pullout strength without installation tools. • Each hub size takes a range of cord diameters. ® E Straight ® E 13938 ® LR 52391 Trade or Hub Size Cord Range Throat Size ± .03 Hex Flat ± .06 A Max. B ± .06 C ± .06 Std. Ctn. c" d" d" d" d" d" f" f" f" f" f" 1" 1" 1" 1" 1" 1" 1" 1" 1b" 1b" 1b" 1b" 1b" 1b" 2" 2" 2" .125-.275 .125-.275 .250-.400 .400-.560 .560-.690 .660-.780 .250-.400 .400-.560 .560-.690 .660-.780 .770-.895 .250-.400 .400-.560 .560-.690 .660-.780 .770-.895 .870-1.020 .890-1.090 1.080-1.280 .890-1.090 1.080-1.280 1.270-1.470 .890-1.150 1.140-1.400 1.390-1.650 1.190-1.530 1.520-1.860 1.850-2.190 0.33 0.33 0.55 0.55 0.54 0.54 0.55 0.55 0.79 0.79 0.76 0.54 0.54 0.98 0.98 0.98 0.98 0.98 0.98 1.25 1.25 1.25 1.47 1.47 1.47 1.89 1.89 1.89 .78 1.00 1.08 1.08 1.32 1.32 1.22 1.22 1.34 1.34 1.64 1.50 1.50 1.60 1.60 1.60 1.60 2.25 2.25 2.25 2.25 2.25 2.65 2.65 2.65 3.13 3.13 3.13 2.0 2.3 2.6 2.6 3.0 3.0 2.7 2.7 3.0 3.0 3.2 2.9 2.9 3.1 3.3 3.3 3.3 4.2 4.0 4.2 4.0 4.0 4.2 4.3 4.3 5.1 4.9 4.9 .90 .90 1.27 1.27 1.57 1.57 1.27 1.27 1.57 1.57 1.89 1.27 1.27 1.89 1.89 1.89 1.89 2.58 2.58 2.58 2.58 2.58 2.95 2.95 2.95 3.50 3.50 3.50 .46 .60 .60 .60 .60 .60 .62 .62 .62 .62 .62 .77 .77 .77 .77 .77 .77 .77 .77 .80 .80 .80 .82 .82 .82 .84 .84 .84 250 100 100 100 100 100 100 100 100 100 100 100 100 100 100 50 10 50 10 10 10 10 10 10 5 5 5 2671† 2690† 2672 2673* 2691* 2692* 2693 2694* 2674 2675 2696* 2697 2698* 2695 2676 2677 2678 2699 2700 2702 2703* 2704* 2705-TB 2706 2707* 2708 2709 2710* Steel City ® Cat. No. *Remove sufficient outer covering of cable to permit conductors to pass thru connector body. †CSA certified for factory installation. Material: Weather Stabilized Nylon, Rated at – 34°C to 105°C Temperature. For 90° Style See AS-72555. ® 90 Degree Angle Cat. No. 2680† 2681 2682* 2683 2684 2688 2685 2686 2687* ® E 13938 ® LR 52391 Trade or Hub Size Cord Range Throat Size Hex Flat A B C D Std. Ctn. c" d" d" f" f" 1" 1" 1" 1" .125-.275 .250-.400 .400-.560 .560-.690 .660-.780 .560-.690 .660-.780 .770-.895 .870-1.020 .33 .55 .55 .78 .78 1.00 1.00 100 1.00 .62 .83 .83 1.06 1.06 1.280 1.280 1.280 1.280 1.8 2.5 2.5 2.8 2.8 3.0 3.0 3.0 3.0 .90 1.27 1.27 1.57 1.57 1.89 1.89 1.89 1.89 .46 .60 .60 .62 .62 .77 .77 .77 .77 1.00 1.35 1.35 1.60 1.60 1.90 1.90 1.90 1.90 100 50 50 50 50 25 25 25 25 *Remove sufficient outer covering of cable to permit conductors to pass thru connector body. †CSA certified for factory installation. © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E31 412034.E01 5/7 5/7/03 4:52 PM Page E32 Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing ® ® Connectors – Liquidtight Flex for Nonmetallic Conduit Cat. No. LT-500 LT-501 LT-502 LT-503 B* ±.35 (0.90) Inch (mm) c" d" f" 1" .570 .570 .582 .726 1.595 (40.51) 1.636 (41.55) 1.757 (44.63) 1.923 (48.84) C ±.015 (0.40) Min. Across Throat E Corners Dia. D. Thread Inch (mm) Inch (mm) NPT. 1.354 1.448 1.740 2.068 .417 .550 .740 .940 d-14 d-14 f-14 1-11/12 F Inch (mm) Approx. Std. Ctn. 1.880 (47.75) 1.986 (50.44) 2.212 (56.18) 2.508 (63.70) 100 100 50 50 Steel City ® E Trade Size A± .015 (0.40) Inch (mm) 90° Connectors – Liquidtight Flex for Nonmetallic Conduit Cat. No. LT-590 LT-591 LT-592 LT-593 Trade Size A± .015 (0.40) Inch (mm) B* ±.35 (0.90) Inch (mm) c" d" f" 1" (14.48) (14.48) (14.78) (18.44) 1.380 (35.05) 1.489 (37.82) 1.790 (45.47) 2.104 (53.44) C ±.015 (0.40) Min. Across Throat E Corners Dia. D. Thread Inch (mm) Inch (mm) NPT. (34.39) (36.78) (44.20) (52.53) (10.59) (13.97) (18.80) (23.88) d-14 d-14 f-14 1-11/12 F Inch (mm) Approx. Std. Ctn. 1.880 (47.75) 1.986 (50.44) 2.212 (56.18) 2.508 (63.70) 50 50 50 25 ® ® Standard Material/Finish • Body/Gland–Nylon-Grey • “O” Ring–Nitrate (Black) • Locknut–Nylon • Temp. Rating–80°C • Material Flammability Rating: UL94-V2 Listed/Certified by: • U.L. Listed (File # E23018) • C.S.A. (File # LR52391) Conforms To: • Watertight requirements for Type 4 45° Connectors – Liquidtight Flex for Nonmetallic Conduit Cat. No. LT-540 LT-541 LT-542 LT-543 Trade Size A± .015 (0.40) Inch (mm) B* ±.35 (0.90) Inch (mm) c" d" f" 1" (14.48) (14.48) (14.78) (18.44) 2.012 (51.10) 2.092 (53.14) 2.452 (62.28) 2.684 (68.17) C ±.015 (0.40) Min. Across Throat E Corners Dia. D. Thread Inch (mm) Inch (mm) NPT. (34.39) (36.78) (44.20) (52.53) (10.59) (13.97) (18.80) (23.88) d-14 d-14 f-14 1-11/12 F Inch (mm) Approx. Std. Ctn. 1.534 (38.95) 1.590 (40.39) 1.821 (46.25) 2.034 (51.66) 50 50 50 25 F* B* A C D E32 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E33 Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing Liquidtight Flexible Nonmetallic Conduit (Type B) Outdoor XTRAFLEX® Raceway System Cat. No. Series I.D. IN. O.D.IN. Min. Max. Min. Max. Std. Ctn. c" d" f" 1" 1b" 1d" 2" .484 .622 .820 1.041 1.380 1.575 2.020 .504 .642 .840 1.066 1.410 1.600 2.045 .690 .820 1.030 1.290 1.630 1.865 2.340 .710 .840 1.050 1.315 1.660 1.900 2.375 100 100 100 100 100 50 50 LTC038GY LTC050GY LTC075GY LTC100GY LTC125GY LTC150GY LTC200GY E Steel City ® Trade Size Color: Gray Length: 100 ft. for LTC038GY thru LTC125GY 50 ft. for LTC150GY and LTC200GY U.L. Listed: File E95745 U.L. Temperature Rating: 80°C dry, 60°C wet, 70°C oil. res. sunlight resistant, outdoor, direct burial. CSA Certified: File LR 80349-2 CSA Temperature Rating: 75°C to-18°C For use with Thomas & Betts LT38P, LT38M, LT500 series and Liquidtight Flexible Metal Conduit Fittings. Material: PVC Helix reinforcement surrounded with flexible PVC. Voltage Rating: 600V ® ® Liquidtight Whip Assembly Cat. No. LTWHIP 12-6-10 LTWHIP 12-4-10 LTWHIP 34-6-8 LTWHIP 34-4-8 Conduit Size Length Wire Gauge Std. Ctn. d" d" f" f" 6' 4' 6' 4' #10 #10 #8 #8 6 6 6 6 6' 4' 6' 4' #10 #10 #8 #8 6 6 6 6 Whip with metallic fittings – one straight, one 90° LTWM 12-6-10 LTWM 12-4-10 LTWM 34-6-8 LTWM 34-4-8 d" d" f" f" Conduit Cutter – For Nonmetallic Flexible Conduit Cat. No. XF-CUT XF-BLADE © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. Description For cutting NM flexible conduit up to 1" Replacement blade for XF-CUT www.tnb.com E33 412034.E01 5/7 5/7/03 4:52 PM Page E34 Liquidtight Fittings Versa Ground™ LIquidtight Fittings B LUG UGRANGE RANGE Cat. No. E Steel City ® A C LUG RANGE LUG RANGE A Trade Size A B Std. Ctn. 5331GR 5332GR 5333GR 5334GR c d f 1 1d" 1l" 1e" 2h" 14-4 14-4 14-4 14-4 100 100 25 50 5231GR 5232GR 5233GR 5234GR 5231ALGR 5232ALGR 5233ALGR 5234ALGR c d f 1 c d f 1 1d" 1l" 1e" 2h" 1d" 1l" 1e" 2h" 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 100 100 25 50 100 100 50 50 Versa Ground™ LIquidtight Fittings – 90° Type Cat. No. Trade Size A B C Std. Ctn. 5353GR 5354GR c d f 1 1c" 1l" 1f" 2i" 1b" 1k" 1m" 2h" 14-4 14-4 14-4 14-4 50 50 50 25 5251GR 5252GR 5253GR 5254GR 5251ALGR 5252ALGR 5253ALGR 5254ALGR c d f 1 c d f 1 1c" 1l" 1f" 2i" 1c" 1l" 1f" 2i" 1b" 1k" 1m" 2h" 1b" 1k" 1m" 2h" 14-4 14-4 14-4 14-4 14-4 14-4 14-4 14-4 50 50 50 25 50 50 50 25 5351GR B 5352GR B LUG RANGE RANGE Versa Ground™ LIquidtight Fittings A Cat. No. C LUGRANGE RANGE BBLUG Trade Size A B C Std. Ctn. 5341GR 5342GR 5343GR 5344GR c d f 1 1l" 1g" 2a" 2b" 14-4 14-4 14-4 14-4 1h" 1c" 1i" 1f" 50 50 50 25 5241GR 5242GR 5243GR 5244GR c d f 1 1l" 1g" 2a" 2b" 14-4 14-4 14-4 14-4 1h" 1c" 1i" 1f" 50 50 50 25 Liquidtight to Rigid External Ground Adapter Cat. No. 5271GR 5272GR 5273GR 5274GR Trade Size A B Std. Ctn. c d f 1 1q" 1c 1y" 1g" 14-4 14-4 14-4 14-4 50 50 50 25 A E34 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E35 Liquidtight Flexible Metal Conduit Connectors ® ® Straight Connectors Cat. No. • 3⁄8"-1" – Steel. • 11⁄4"-2" – Malleable Iron/Zinc Plated. Conduit Size A Diameter B C Std. Ctn. c" d" f" 1" 1b" 1d" 2" 1h" 1i" 1k 1f" 2k" 2f" 3w" d" T" l" e" L" A" A" 1m" 1g" 2o" 2s" 2x" 2A" 3r" 100 100 50 50 25 10 5 LT-100 LT-101 LT-102 LT-103 LT-104 LT-105 LT-106 E ® ® Straight Connectors Cat. No. • 3⁄8"-1" – Steel. • 11⁄4"-2" – Malleable Iron/Zinc Plated (with insulated throat). LT-700 LT-701 LT-702 LT-703 LT-704 LT-705 LT-706 Conduit Size A Diameter B C Std. Ctn. c" d" f" 1" 1b" 1d" 2" 1h" 1i" 1k" 1f" 2k" 2f" 3w" d" T" l" e" L" A" A" 1C" 1O" 2a" 2c" 2L 2g" 3j" 100 100 50 50 25 10 5 ® ® 45° Connectors – Malleable Iron/Zinc Plated Cat. No. Conduit Size E c" d" f" 1" 1h" 1i" 1k" 1f" LT-450 LT-451 LT-452 LT-453 Dimensions F d" d" l" e" G H Std. Ctn. 1l" 1e" 1g" 2a" O" 1" 1p" 1s" 50 50 50 25 G I Std. Ctn. 1l" 1e" 1g" 2a" 1h" 1p" 1i" 1c" 50 50 50 25 CSA File No. LR-12798 U.L. File No. E-1275 45° Connectors – Malleable Iron/Zinc Plated (with insulated throat) Cat. No. Conduit Size E c" d" f" 1" 1h" 1i" 1k" 1f" LT-950 LT-951 LT-952 LT-953 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com Dimensions F d" d" l" e" E35 Steel City ® CSA File No. LR-12798 U.L. File No. E-1275 -c"-4" 412034.E01 5/7 5/7/03 4:52 PM Page E36 Liguidtight Flexible Metal Conduit Connectors ® ® 90° Connectors – Malleable Iron/Zinc Plated Cat. No. Dimensions Conduit Size J K L M Std. Ctn. c" d" f" 1" 1h" 1i" 1k" 1f" d" d" l" e" 1g" 2" 2i" 2l" 1c" 1u" 1y" 1g" 50 50 50 25 LT-490 LT-491 LT-492 LT-493 CSA File No. LR-12798 U.L. File No. E-1275 Steel City ® E 90° Connectors – Malleable Iron/Zinc Plated (with insulated throat) Cat. No. Dimensions Conduit Size J K L N Std. Ctn. c" d" f 1" 1h" 1i" 1k" 1f" d" d" l" e" 1g" 2" 2i" 2i" 1v" 1d" 1f" 1O" 50 50 50 25 LT-990 LT-991 LT-992 LT-993 ® Straight Connectors – Die-Cast Zinc Cat. No. LT-200 LT-201 LT-202 LT-203 LT-205 LT-206 LT-207 LT-208 LT-209 LT-210 Conduit Size A Diameter B C Std. Ctn. c" d" f" 1" 1d" 2" 2d" 3" 3d" 4" 1.81" 1.88" 2.03" 2.28" 2.78" 3.22" 3.53" 3.91" 4.04" 4.16" 0.50" 0.61" 0.56" 0.63" 0.78" 0.78" 0.84" 0.88" 0.91" 0.94" 1.06" 1.19" 1.44" 1.75" 2.75" 3.53" 4.28" 4.72" 5.42" 5.91" 100 200 100 50 20 20 1 1 1 1 U.L. File No. E-1275 ® Straight Connectors – Die Cast Zinc (with insulated throat) Cat. No. LT-800 LT-801 LT-802 LT-803 Conduit Size A Diameter B C Std. Ctn. c" d" f" 1" 1I" 1I" 2D" 2F" E" E" E" H" 1x" 1x" 1c" 1G" 100 100 100 50 CSA File No. LR-12798 E36 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E37 Liquidtight Flexible Metal Conduit Connectors ® 90° Connectors – Die-Cast Zinc Cat. No. LT-290 LT-291 LT-292 LT-293 LT-294 LT-295 LT-296 Conduit Size A Diameter B C Std. Ctn. c" d" f" 1" 1b" 1d" 2" 1.88" 2.00" 2.19" 2.56" 3.00" 3.38" 4.06" 1.38" 1.41" 1.66" 1.88" 2.00" 2.56" 3.00" 0.50" 0.50" 0.56" 0.63" 0.69" 0.78" 0.78" 100 100 100 50 40 20 10 Steel City ® U.L. File No. E-1275 90° Connectors – Die-Cast Zinc (with insulated throat) Cat. No. LT-890 LT-891 LT-892 LT-893 Conduit Size A Diameter B C Std. Ctn. c" d" f" 1" 1.88" 2.00" 2.19" 2.56" 1.38" 1.41" 1.66" 1.88" 0.50" 0.50" 0.56" 0.63" 100 100 100 50 Sealing “O” Rings Cat. No. SR-101 SR-102 SR-103 SR-104 SR-105 SR-106 Conduit Size Std. Ctn. d" f" 1" 1b" 1d" 2" 500 500 500 250 250 250 Material: Neoprene © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. E www.tnb.com E37 412034.E01 5/7 5/7/03 4:52 PM Page E38 Nonmetallic Sheathed Cable and Flexible Cord Connectors ® ® All Plastic Connector for NM Cable and Flexible Cord E K.O. Size Fig. A B C D E F Max. Thk. Enclosure For use with 10-2, 12-2 and 14-2 NM cables; 18-2 and 18-3 SJ and SJO cords and 18-2 SV, SVO, SJT and SJTO cords, single or multiple; cord capacity .125-.300 diameter d" 2 1o n c .880 .795 3201 For use with 10-3, 12-3, 14-3, 10-2, 12-2, 4-2 NM cables; multiple (2) 12-2 and 14-2 N M cables; single and multiple flexible cords in wire range .300 in. to .600 in. d" 1 1X 1 k .880 3202 For use with 8-3 and 6-3 NM cables; (2) 14-3, 14-2, 12-2 and 10-2 NM cables; single and multiple flexible cords in wire range .500 in. to .850 in. f" 1 1d 1j Cat. No. Size Range 3300 Steel City ® Snap captive locking wedge into connector’s cavity. Press locking wedge into cavity which locks onto cable. Std. Ctn. .080 jxl 500 .795 .080 y dia. 500 k 1.100 1.005 .090 g dia. 250 Temperature Rating: 105°C CSA File Nos. 584 and 2884 U.L. File No. E-23017 H Hole Size Cat. No. 3201 is ideal for multiple flexible cords and cable. H H Hole Size Figure 1 Figure 2 • High impact thermoplastic. U.L. 94-V1. • Features push-in design . • Captive locking wedge secures cable with single squeeze of standard electrician’s pliers. • Provides excellent insulation, strain-relief and high pull-out value. E38 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E39 Nonmetallic Sheathed Cable Fittings Hit Lock Connectors .400 Cat. No. .580 NC501-SC NC501DBL-SC NC502-SC SB1216-SC Description Std. Ctn. d” Hit Lock Connector d” Double Hit Lock Connector f" Hit Lock Connector Twist It Bushing For Metal Studs 500 500 100 50 1.030 E NC501-SC 1.250 Steel City ® 1.000 2.485 .580 1.315 1.120 1.300 .115 NC502-SC NC501DBL-SC SB1216-SC ® ® NM Clamp Type Connector – Die Cast Zinc Cat. No. NC-201 NC-202 NC-203 NC-204 NC-205 NC-206 Conduit Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. c" f" 1" 1b" 1c" 2" 0.40" 0.50" 0.62" 0.50" 0.75" 0.90" 0.95" 1.10" 1.14" 1.38" 1.61" 2.04" 1.87" 1.84" 2.00" 2.28" 2.49" 3.35" 250 200 100 100 50 50 CSA File No. LR-12798 U.L. File No. E-17583 ® ® Clamp Type Connector – Die Cast Zinc Cat. No. Conduit Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. NC-301 NC-302 NC-303 c" (d"KO) f" 1" 0.18" 0.41" 0.34" 0.64" 0.82" 0.94" 1.16" 1.87" 2.01" 1000 500 250 CSA File No. LR-12798 U.L. File No. E-17583 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E39 412034.E01 5/7 5/7/03 4:52 PM Page E40 Nonmetallic Sheathed Cable Fittings ® Connectors Clamp Type, Non-Watertight – Die Cast Zinc Cat. No. NC-041 NC-051 NC-061 Conduit Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. 1b" 1d" 2" 0.27" 0.54" 0.75" 0.75" 0.95" 1.12" 2.02" 2.50" 3.41" 100 50 40 U.L. File No. E-15170-1b"-1d" U.L. File No. E-17583-2" Steel City ® E ® ® Duplex Clamp Type Connector – Die Cast Zinc Conduit Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. XC-210 XC-211-SC XC-222-SC c" (d" KO) c" c" 0.13" 0.24" 0.24" 0.65" 0.63" 0.63" 1.56" 1.59" 1.59" 250 200 200 Conduit/Cable FMC AC MCC MCI NM MAX. SIZE MIN. SIZE c" c" 10/2 14/2 .565 .425 .565 .425 10/2 14/2 Cat. No. For use with aluminum smooth extruded metal clad cable. (min. dia. .410) – (max. dia. .500) CSA File No. LR-12798 U.L. File No. E-17909 1-1h" A max. A min. NM Saddle Type Connectors – Die Cast Zinc Cat. No. Dimensions (in.) XC-2200-C Size A (min.) A (max.) Std. Ctn. c" 0.12" 0.63" 500 Tilt In Connector Metallic Steel – Electro-Galvanized Cat. No. NC-850 NC-851 NC-852 NC-853 E40 Conduit Size A B C D E Std. Ctn. d" f"-1 1-b" 1-d" .050 .050 .062 .062 .950 1.250 1.625 1.970 1.312 1.750 2.125 2.500 .650 .760 .760 .785 8-32 x f 8-32 x 1 10-32 x 1 10-32 x 12 1000 500 250 100 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E41 Armored Cable/Flexible Metallic Conduit Fittings Straight Connectors ® Straight Squeeze Type Connectors– Malleable Iron or Stamped Steel / Zinc Plated Cat. No. Unit Qty. Std. Ctn. c" (d" K.O.) d" f" 1" 1b" 1d" 2" 2d" 3" 50 25 25 25 5 10 10 5 5 100 100 100 100 10 10 10 5 5 UL File No. E-17909 d"-f" UL File No. E-1275 1"-3" c"-f"-STEEL Straight Squeeze Type Connectors– Insulated Malleable Iron or Stamped Steel / Zinc Plated Cat. No. XC-901 XC-902 XC-903 XC-904 XC-905 XC-906 XC-907 XC-908 Conduit Size Unit Qty. Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 25 25 25 5 10 10 5 5 100 100 100 10 10 10 5 5 d"-f"-STEEL Clamp Straight Set, 90°, and Duplex Connectors 90° Angle Squeeze Type Connectors–Steel or Malleable Iron / Zinc Plated Cat. No. XC-490 XC-491 XC-492 XC-493 XC-494 XC-495 XC-496 XC-497 XC-498 Conduit Size Unit Qty. Std. Ctn. c" (d" K.O.) d" f" 1" 1b" 1d" 2" 2d" 3" 50 25 25 25 10 10 5 1 1 100 100 50 25 10 10 5 1 1 For die cast armored cable/flexible metallic conduit fittings and combination fittings refer to the Steel City® Die Cast Conduit Fittings section. UL File No. E-17909 c" & f" UL File No. E-1275 1"-3" c"-f"-STEEL © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E41 E Steel City ® XC-400 XC-401 XC-402 XC-403 XC-404 XC-405 XC-406 XC-407 XC-408 Conduit Size 412034.E01 5/7 5/7/03 4:52 PM Page E42 Armored Cable/Flexible Metallic Conduit Fittings ® ® Straight Squeeze Type Connectors – Die Cast Zinc Cat. No. XC-269 XC-270 XC-272 XC-273 XC-274 XC-275 XC-276 XC-277 XC-278 XC-278A XC-2710 Steel City ® E Fig. Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. 1 1 1 2 2 2 3 3 3 3 3 c" (d" KO) d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 0.45" 0.74" 0.88" 1.10" 1.48" 1.68" 2.12" 2.71" 3.15" 3.20" 3.15" 0.60" 0.92" 1.10" 1.35" 1.65" 2.00" 2.47" 3.08" 3.60" 4.03" 4.25" 0.96" 1.43" 1.59" 1.60" 1.91" 2.12" 2.54" 2.88" 3.88" 5.04" 5.04" 500 250 250 100 100 50 40 10 5 1 1 U.L. File No. E-17909 c" & 1" U.L. File No. E-1275 1b"-2" CSA File No. LR-12798 c"-1" ® ® Straight Squeeze Type Connectors – Insulated Die Cast Zinc Cat. No. Figure 1 XC-870 XC-872 XC-873 XC-874 XC-875 XC-876 XC-877 XC-878 XC-879 XC-8710 Fig. Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. 1 1 2 2 2 3 3 3 3 3 d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 0.74" 0.88" 1.10" 1.48" 1.68" 2.12" 2.71" 3.15" 3.20" 3.15" 0.92" 1.10" 1.35" 1.65" 2.00" 2.47" 3.08" 3.60" 4.03" 4.25" 1.43" 1.59" 1.60" 1.91" 2.12" 2.54" 2.88" 3.88" 5.04" 5.04" 250 250 100 50 50 10 10 5 1 1 U.L. File No. E-17909-d"-f" U.L. File No. E-1275-1b" CSA File No. LR-12798 Figure 2 E42 Figure 3 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E43 Armored Cable/Flexible Metallic Conduit Fittings ® ® Steel City® Cable Lok Cat. No. AC Steel AC Aluminum Interlocked MC (I) Steel MC (I) Aluminum Flex RW Std. Ctn. .450"/.610" 14/2 14/3 14/4 12/2 12/3 12/4 10/2 14/2 14/3 14/4 12/2 12/3 12/4 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 c Steel & AL 50 XC-730 d" K.O. XC-731 d" K.O. .450"/.610" 14/2 14/3 14/4 12/2 12/3 12/4 10/2 14/2 14/3 14/4 12/2 12/3 12/4 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 XC-732 f" K.O. .610"/.875" 10/3 10/4 10/5 8/3 8/4 6/2 XC-7300 d" K.O. .450"/.610" 14/2 14/3 14/4 12/2 12/3 12/4 10/2 – 14/2 14/3 14/4 12/2 12/3 12/4 10/4 10/5 8/3 8/4 6/2 – 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 50 – c Steel & AL E 25 25 – U.L. File No. E-17909 CSA File No. LR-12798 Simple, fast steps to installing the Steel City® Cable Lok. 1. Simply snap into place. No locknuts required! 2. Insert cord and twist set screw. Connector tightens as screw is set. © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E43 Steel City ® • Simple, one-piece installation with no locknuts. • Screw designed for exceptional pullout resistance. • Captive screw ensures that the screw is intact for installation and resists backing out after installation. • Corrosion-resistant, zinc-chromatic plating. • Positive grounding. • Vibration resistant screw design. • UL listed and CSA certified. Size Range 412034.E01 5/7 5/7/03 4:52 PM Page E44 Armored Cable/Flexible Metallic Conduit Fittings ® ® 90° Clamp Type Connectors – Die Cast Zinc Cat. No. Figure 1 Steel City ® E XC-290 XC-291 “Threads” XC-292 XC-293 XC-294 XC-295 XC-296 XC-297 XC-298 XC-299 XC-2910 Fig. Conduit Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. 1 1 1 2 2 3 3 4 5 4 4 c" (d" KO) d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 0.40" 0.65" 0.83" 1.27" 1.49" 1.51" 1.51" 2.45" 3.07" 3.63" 3.68" 0.63" 1.00" 1.25" 1.50" 1.85" 2.47" 2.47" 3.50" 4.02" 4.34" 5.17" 1.80" 2.08" 2.27" 2.60" 3.10" 6.05" 6.05" 7.75" 8.88" 12.75" 12.75" 500 250 100 50 30 5 5 2 1 1 1 U.L. File No. E-17909 CSA File No. LR-18130M57 Insulated Die Cast Zinc “Threads” Figure 2 Cat. No. XC-890 XC-891 XC-892 XC-893 XC-894 XC-895 XC-896 XC-897 XC-898 XC-899 XC-8910 “Threads” Figure 3 Fig. Conduit Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. 1 1 1 2 2 3 3 4 5 4 4 c" d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 0.40" 0.65" 0.77" 1.06" 1.34" 1.51" 1.51" 2.45" 3.07" 3.63" 3.68" 0.63" 0.97" 1.12" 1.40" 1.65" 2.47" 2.47" 3.50" 4.02" 4.34" 5.17" 1.81" 2.18" 2.38" 2.87" 3.93" 6.05" 6.05" 7.75" 8.88" 12.75" 12.75" 500 250 100 50 30 5 5 2 1 1 1 U.L. File No. E-17909 CSA File No. LR-12798 “Threads” Figure 4 “Threads” Figure 5 E44 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E45 Armored Cable/Flexible Metallic Conduit Fittings ® ® A max. A min. Clamp Type Connector – Die Cast Zinc Conduit Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. c" (d" KO) 0.18" 0.64" 1.16" 1000 Cat. No. XC-280 U.L. File No. E-17909 CSA File No. LR-18130M57 E Duplex Clamp Type Connector – Die Cast Zinc For use with metal clad cable. A (min.) Dimensions (in.) A (max.) B Std. Ctn. XC-210 c" (d" KO) 0.13" 0.65" 1.56" 250 Steel City ® Conduit Size Cat. No. CSA File No. LR-18130M57 ® Cable Range Cat. No. Continuous Corrugated and Corrugated min. dia. max. dia. – – XC-280 XC-210 Aluminum Smooth Extruded min. dia. max. dia. .510" – .345" .410" .525" .500" Std. Ctn. 1000 250 1-1h" Snap-In Connector for Flexible Metal Conduit – 105°C Rated Cat. No. Conduit Size K.O. Size Unit Qty. Std. Ctn. c" c" d" d" 50 250 500 1000 100-TB 100BP • No locknut required. • No special tools required. • High impact thermoplastic with steel insert. BX Flex Bushings – Anti-Short Cat. No. IT-100-SC IT-101 IT-102 IT-103 IT-104 • Packed in polybags. • Available bulk packed-10,000 per carton. • Plastic. Fits Standard Cable Range Size Unit Qty. Std. Ctn. 14/2-14/3-12/2 14/4-12/3-6/1-4/1 12/4-10/2-10/3-2/1 10/4-8/2-8/3-1/1 8/4-6/2-6/3-4/2-4/3-6/4 0 1 2 3 4 100 100 50 50 50 100 35 50 50 50 For die cast armored cable/flexible metallic conduit fittings and combination fittings refer to the Steel City® Die Cast Conduit Fittings section. Ordered by Bags © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E45 412034.E01 5/7 5/7/03 4:52 PM Page E46 Armored Cable/Flexible Metallic Conduit Fittings ® A max. A min. Straight Set Screw Connectors – Die Cast Zinc – Noninsulated B Cat. No. A max. A min. B XC-220 XC-221 XC-821 Dimensions (in.) A (max.) A (min.) B Std. Ctn. XC-220 c" (d" KO) 0.38" 0.63" 0.84" 1000 XC-221 d" 0.74" 0.94" 1.46" 250 XC-821 d" 0.74" 0.94" 1.46" 250 XC-220 and XC-221: U.L. File No. E-17909 c" U.L. File No. E-1275 d" XC-821: U.L. File No. E-1275 d" E A max. Steel City ® Size A min. BX Flex Connectors, Saddle Type – Die Cast Zinc Cat. No. XC-2200-C Size A (min.) Dimensions (in.) A (max.) B Std. Ctn. c" 0.12" 0.63" 0.98" 500 ® ® Screw-In Connectors – Die Cast Zinc – Noninsulated A Dimensions (in.) Cat. No. XC-240 XC-241 XC-242 XC-243 XC-244 XC-245 XC-246 B Size A B Std. Ctn. c" (d" KO) d" f" 1" 1b" 1d" 2" 1.31" 1.38" 1.62" 1.94" 2.12" 2.31" 2.58" 0.92" 0.92" 1.12" 1.37" 1.75" 2.13" 2.67" 500 500 125 125 50 50 50 U.L. File No. E-1275 CSA File No. LR-18130M57 c"-d" ® ® Screw-In Connectors – Die Cast Zinc – Insulated A Dimensions (in.) Cat. No. XC-840 XC-841 XC-842 XC-843 XC-844 XC-845 XC-846 B Size A B Std. Ctn. c" (d" KO) d" f" 1" 1b" 1d" 2" 1.31" 1.38" 1.62" 1.94" 2.12" 2.31" 2.58" 0.92" 0.92" 1.12" 1.37" 1.75" 2.13" 2.67" 500 500 125 125 50 50 50 U.L. File No. E-1275 CSA File No. LR-18130M57 c"-d" ® Screw-In Couplings – Die Cast Zinc A B Dimensions (in.) Cat. No. Size A B Std. Ctn. XK-241 XK-242 XK-243 XK-244 XK-245 XK-246 d" f" 1" 1b" 1d" 2" 1.81" 2.09" 2.41" 2.75" 3.05" 3.28" 0.92" 1.12" 1.37" 1.81" 2.12" 2.67" 250 250 125 50 50 50 U.L. File No. E-1275 E46 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E47 Cable Straps, Cable Caps Service Cable Straps – One Hole Cat. No. SE100 SE101 SE102 SE103 Fits Cable Shelf Ctn. Ship Case Std. Ctn. 3#8, 3#6, 3#4 3#3, 3#2 3#1, 3#0, 3#1/0, 3#2/0 3#3/0, 3#4/0 100 100 25 25 1000 1000 250 250 1000 1000 250 250 E Cat. No. SE900 SE901 SE902 SE903 Fits Cable Shelf Ctn. Ship Case Std. Ctn. 3#8, 3#6, 3#4 3#3, 3#2 3#1, 3#0, 3#1/0, 3#2/0 3#3/0, 3#4/0 100 100 25 25 1000 1000 250 250 1000 1000 250 250 Service Cable Caps – Oval Cat. No. 50130 50130A Fits Cable A Dimensions (Inches) B C Std. Ctn. To 2/0-3 To 4/0-3 5.00 6.75 3.31 4.62 4.75 6.00 10 5 3#3-2 3#3/0-4/0 2.37 4.93 2.12 3.12 2.25 3.75 25 10 With Split Insulator SC1000 SC2001 Extra Large Body for Additional Wiring Space. © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E47 Steel City ® Service Cable Straps – Two Hole 412034.E01 5/7 5/7/03 4:52 PM Page E48 Service Entrance Fittings ® ® Aluminum Service Caps – Clamp Type for Rigid/Intermediate or Thinwall Cat. No. SH-101 SH-102 SH-103 SH-104 SH-105 SH-106 SH-107 SH-108 SH-109 SH-110 Steel City ® E Conduit Size No. Hole Size Std. Ctn. d" f" 1" 1b" 1d" 2" 2d" 3" 3d" 4" 4 5 5 5 6 6 7 7 4 4 ∫" 2(c") 3(u") 2(k") 3(d") 2(N") 3(e") 2(x") 1(k") 3(f") 2(f") 3(1") 1(w") 3(g") 1(1") 3(1j") 4(1a") 3(1f") 4(1f") 2(a") 4(1f") 2(1a") 50 50 10 10 5 5 1 1 1 1 CSA File No. LR-12798 U.L. File No. E-22753 ® Service Entrance Fittings B Cat. No. A ASLB-1 ASLB-2 ASLB-3 ASLB-4 ASLB-5 ASLB-6 DASLB-1 DASLB-2 DASLB-3 Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" d" f" 1" 3h 3l 4b 5d 6b 6f 3h 3l 4b 1l 1f 2i 3 3b 4 1l 1f 2i 50 50 25 10 10 5 24 20 8 ® Service Entrance Fittings – Standard d" - 2" Cat. No. ASLB-1 ASLB-2 ASLB-3 ASLB-4 ASLB-5 ASLB-6 Trade Size A B Std. Ctn. d" f" 1" 1b" 1d" 2" 3h 3l 4b 5d 6b 6f 1l 1f 2i 3 3b 4 50 50 25 10 10 5 TYPE LB Service Entrance Fittings – Standard d" - 4" Cat. No. SALB-7 SALB-8 SALB-9 SALB-10 E48 Trade Size A B Std. Ctn. 2d" 3" 3d" 4" 3h 3l 4b 5d 1l 1f 2i 3 50 50 25 10 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E49 Grounding Clamps/Connectors ® Ground Clamps – Die Cast Zinc Alloy for Armored Ground Wire Cat. No. GA-203 Conduit Conduit Size Std. Ctn. d"; f"; 1" 250 U.L. File No. E-10661 Two-screw ground connection for armored ground wire. Ground Clamps – Die Cast Zinc, Brass Colored Cat. No. Std. Ctn. d"; 1" 200 GC-203-B Water-Tight Connectors B A • For Type SE, Style U, Flat; 2 Insulating Conductors, 1 Bare. Cat. No. WT-203A WT-203B WT-203C WT-204A WT-204B WT-204C WT-204D WT-205A WT-205B WT-205C WT-206A WT-206B WT-206C WT-206D WT-206E Rubber Grommet Opening A B Trade Size Fits Cable Std. Ctn. 1" 1" 1" 1b" 1b" 1b" 1b" 1d" 1d" 1d" 2" 2" 2" 2" 2" 3#8 3#6 3#4 3#3 3#2 3#1 3#1/0 3#1/0 & 3#2/0 3#2/0 & 3#3/0 3#2/0 & 3#3/0 3#1/0 & 3#2/0 3#2/0 & 3#3/0 3#2/0 & 3#3/0 3#4/0 3#4/0 .500 .563 .625 .625 .580 .660 .750 .735 .875 .938 .735 .875 .938 .890 1.063 .750 .844 .938 1.000 .960 1.090 1.125 1.240 1.375 1.438 1.240 1.375 1.438 1.550 1.688 100 100 100 50 50 50 50 20 20 20 20 20 20 20 20 2#14 3#14 .210 .220 .440 .660 250 250 For Underground Feeder Cable UF-201 UF-202 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. d" f" www.tnb.com E49 E Steel City ® Conduit Conduit Size 412034.E01 5/7 5/7/03 4:52 PM Page E50 Gutter Connectors/Cable Protector and Cable Clip Gutter Connectors Replaces conventional method of nipple, locknuts and bushings to interconnect panel boxes and other type enclosures to troughs or gutters. Gutter connectors provide automatic uniform 1" spacing with no threads showing. Conventional installation requires that a nipple be used with double locknuts at 1-2o" A Steel City ® E both ends or with a bushing and locknut at each end. Also, when using two or more nipples, time is consumed adjusting the nipples for straight alignment of the enclosure. Gutter connectors eliminate these time consuming methods. The three piece connector requires the tightening of only one locknut. ® Gutter Connectors Straight Cat. No. Locknut 1" Spacer UC-101 UC-102 UC-103 UC-104 UC-105 UC-106 Conduit Size A Dia. Std. Ctn. d" f" 1" 1b" 1d" 2" 1a" 1k" 1f" 2a" 2d" 2n" 250 250 150 90 50 30 U.L. File No. E-1275 Fitting 3 Pieces Steel/Zinc Plated Cable Protector Cat. No. CP-1 Description Std. Ctn. Steel 100 Description Std. Ctn. Steel 1000 Cable Clip 1l" Cat. No. NS-100 1" 1c" 1a" c" E50 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E51 Beam Clamps for Mounting Pipe or Conduit Conduit/Pipe to Beam Clamps Cat. No. & Size Dimensions in Inches O.D. of Conduit or Pipe Nom. Conduit or Pipe Size Std. Ctn. .840 1.050 1.315 1.660 1.900 2.375 d f 1 1b 1d 2 50 50 50 50 50 50 .675 .840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 c d f 1 1b 1d 2 2d 3 3d 4 50 50 50 50 50 50 50 25 25 25 20 .840 1.050 1.315 1.660 1.900 2.375 2.875 d f 1 1b 1d 2 2d 50 50 25 25 25 25 10 .675 .840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 c d f 1 1b 1d 2 2d 3 3d 4 50 50 50 50 25 25 25 25 10 10 10 RCS Clamp – Steel RCS Series RC Clamp – Malleable Iron RC-3/8 RC-1/2 RC-3/4 RC-1 RC-1-1/4 RC-1-1/2 RC-2-SC RC-2-1/2 RC-3 RC-3-1/2 RC-4-SC EC Clamp – Malleable Iron EC Series • For mounting pipe or conduit vertically across the beam. • HDG Suffix – Hot Dip Galvanized. EC-1/2 EC-3/4 EC-1 EC-1-1/4 EC-1-1/2 EC-2 EC-2-1/2 PC Clamp – Malleable Iron PC-3/8 PC-1/2 PC-3/4 PC-1 PC-1-1/4 PC-1-1/2 PC-2 PC-2-1/2 PC-3 PC-3-1/2 PC-4 PC Series • For mounting pipe or conduit parallel to the beam. • HDG Suffix – Hot Dip Galvanized. © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E51 E Steel City ® • For mounting pipe or conduit at right angles to the beam. • SS316 Suffix Stainless Steel. • HDG Suffix – Hot Dip Galvanized. RCS-1/2 RCS-3/4 RCS-1 RCS-1-1/4 RCS-1-1/2 RCS-2 412034.E01 5/7 5/7/03 4:52 PM Page E52 Conduit and Pipe Hangers ® 6H Series Conduit and Pipe Hangers – Without Bolt Cat. No. Without Bolt Steel City ® E All Steel City 6H Hanger Bolts include a combination Slot-Phillips Head. For hanging conduit (rigid or EMT) and pipe. The 6H series hangers are fast, easy and economical to use. May be fastened directly to a #500 beam clamp through a hole in the base of the hanger by means of a 1⁄4-20 stove bolt or suspended on 1⁄4" hanger rod. Size (in.) Rigid Conduit or Pipe EMT A B C D (dia.) Load Rating Std. Ctn. c-d c-d f f 1 – 1b d d f f 1 1b 1d f f g g g g g .045 .045 .045 .045 .045 .045 .045 1y 1B 1O 2s 2c 2z 2g s s s s s s s 500 500 500 500 500 500 500 100 100 100 100 100 100 100 1d 2 2d 3 3d 4 – 2 – – – 4 1 1b 1b 1b 1b 1b .071 .071 .071 .071 .071 .071 3c 3C 4s 5i 5k 5g X X X X X X 500 500 500 500 500 500 100 50 50 25 25 10 6H0 6H0-T 6H1 6H1-T 6H2 6H2-1/2 6H3-SC 6H4 6H5 6H6 6H7 6H8 6H9 Dimensions (in.) * Add SS suffix to part number for stainless steel. Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt. Standard finishes: electrogalvanized and Type 302 Stainless Steel. ® 6H Series Conduit and Pipe Hangers – With Bolt Cat. No. Size (in.) Rigid Conduit or Pipe EMT A B C D (dia.) Load Rating Std. Ctn. c-d c-d f f 1 – 1b d d f f 1 1b 1d f f g g g g g .045 .045 .045 .045 .045 .045 .045 1y 1B 1O 2s 2c 2z 2g s s s s s s s 500 500 500 500 500 500 500 100 100 100 100 100 100 100 1d 2 2d 3 3d 4 – 2 – – – 4 1 1b 1b 1b 1b 1b .071 .071 .071 .071 .071 .071 3c 3C 4s 5i 5k 5g X X X X X X 500 500 500 500 500 500 100 50 50 25 25 10 6H0-B 6H0-TB 6H1-B 6H1-TB 6H2-B 6H2-1/2-B 6H3-SC-B 6H Without bolt. 6H-B With bolt and hex nut. 6H4-B 6H5-B 6H6-B 6H7-B 6H8-B 6H9-B Dimensions (in.) * Add SS suffix to part number for stainless steel. (not UL listed.) Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt. Standard finishes: electrogalvanized and Type 302 Stainless Steel. 6H-T Threaded without bolt. 6H-TB Threaded with bolt. Beam Clamp Cat. No. Size Tapped Std. Ctn. BC1-TB 1 b-20 250 BC2-TB 2n c-16 – Material: Steel Finish: Zinc Plated E52 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 412034.E01 5/7 5/7/03 4:52 PM Page E53 Beam Clamps/Threaded Rod/Rod Coupling Beam Clamps – Malleable Iron, Electroplated Finish Cat. No. A B Jaw Opening Inches B B 1 1 1d 2 2e 2d 2d 1a 1a 1b 1b 1e 2 2d 2c 2c e e n n g 1 1 1c 2a Tapping of Base and Back Holes Load Rating‡ Std. Ctn. b-20 10-24 b-20 10-24 j-18 c-16 d-13 d-13 d-13 400 400 450 375 800 1300 1300 1700 1700 100 100 50 100 50 50 20 20 10 ‡Safety Factor of 3. Loan Ratings based on bottom hole of Beam Clamp. CSA File No. LR-52208 R-Series Continuous Thread Rod – Galvanized Cat. No. Rod Size Ultimate‡ Load in Lbs. Root Area Thread R628-6 ft. R638-6 ft. R648-6 ft. R1028-10 ft. R1038-10 ft. R1048-10 ft. b-20 c-16 d-13 b-20 c-16 d-13 900 1900 3500 900 1900 3500 .027 .068 .126 .027 .068 .126 Data for Pressure Piping Nominal Max. Safe Pipe Size Load at 450° f" to 2" 2d" to 3d" 610 1130 f" to 2" 2d" to 3d" 610 1130 Std. Ctn. 300 150 60 500 250 100 ‡Load Ratings based on safely factor of three. H-195 Steel Rod Coupling Cat. No. H-195-1/4 H-195-3/8 H-195-1/2 H-195-5/8 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. Rod Size b c d e www.tnb.com Dimensions in Inches A B Std. Ctn. f 1 1 1d 1000 500 500 50 c d e f E53 E Steel City ® 510 511-SC 500-SC 509 501 502 503-SC 507 508 Base Size Inches 412034.E01 5/7 5/7/03 4:52 PM Page E54 Steel City... ® Building on a century of trust! Steel City Fittings for added convenience and reliability. And we’ve added a new line of over 600 Steel City Spring Steel Fasteners that meet all the current UL test requirements. Thomas & Betts and you – together we’re building on a century of trust. For technical information about any product in the Steel City line, call 1-888-862-3289. You’ve told us what your customers say ... how they work ... and what they need for a better, faster, easier job. And we’ve used your feedback to make Steel City® the most versatile and trusted brand in the industry! And now the line is bigger and stronger than ever. Steel City® boxes now include exclusive new features to help simplify and speed up installations. We’ve upgraded the extensive line of CK Series Conduit to Drop Wire Fasteners Larger finger tab, better leverage, makes it easier to secure MC/AC cables and conduit to drop wire, plain and threaded rods, and flanges. SH2346 Box-to-Stud Bracket Unique side brace allows one part number to attach boxes to 2 1/2,” 3 1/2,” 4,” or 6” metal or wood studs. (Competition needs three.) Steel City • Red•Dot • Superstrut • Union • Bowers ® ® ® ® ®