INSTALLATION INSTRUCTIONS Relume RPSWP1 Rev Level _D__ Rev Date _10/22/13__ WARNING: Make sure that all power is turned off while installing fixture. Do not turn power on until fixture is completely installed. Turn power off at circuit breaker box. Do not handle an energized fixture or energize any fixture when hands are wet or when standing on a wet or damp surface, or in water. AVERTISSEMENT: Assurez-vous que l'alimentation est coupée pendant l'installation luminaire. Ne mettez pas sous tension tant que luminaire est complètement installé. Coupez le courant à la boîte du disjoncteur. Ne pas manipuler un appareil hors tension ou sous tension un appareil lorsque vos mains sont mouillées ou debout sur une surface mouillée, humide ou dans l'eau. THIS LED FIXTURE IS A HIGHLY ADVANCED, ENERGY EFFICIENT PRODUCT THAT WILL PROVIDE THE END USER WITH YEARS OF DEPENDABLE SERVICE. IT WILL DO SO ONLY IF INSTALLED PROPERLY IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND OR LOCAL CODE SPECIFICATIONS. FAILURE TO ADHERE TO THESE CODES AND RESTRICTIONS MAY RESULT IN SERIOUS INJURY, DAMAGE TO ADJACENT EQUIPMENT, FIXTURE AND OR POWER SUPPLY AND WILL VOID THE WARRANTY. THE INSTALLATION INSTRUCTIONS DO NOT SUPPORT ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL POSSIBLE CONTINGENCIES RELATED TO THE INSTALLATION, SERVICE OR MOUNTING SITUATION. SHOULD SPECIFIC PROBLEMS OCCUR THAT ARE NOT COVERED BY THE ATTACHED INSTALLATION INSTRUCTIONS, PLEASE CONTACT YOUR SALES REPRESENTATIVE OR DISTRIBUTOR FOR ASSISTANCE. RETAIN THESE INSTALLATION INSTRUCTIONS FOR FUTURE USE. DO NOT MODIFY THIS LIGHTING DEVICE FOR ANY REASON. THESE DEVICES HAVE BEEN DESIGNED FOR MAXIMUM PERFORMANCE AND EASE OF INSTALLATION, ANY MODIFICATIONS WILL VOID THE WARRANTY. Proper grounding of the fixture is essential to prevent risk of shock, to maintain correct operation and to eliminate electrical interference. It is the responsibility of the installer to ensure water cannot enter fixture through conduit or mounting. Install driver and electrical components in dry locations only. If occupancy sensors are installed – Sensors and controls are factory set and may need to be adjusted in the field at installation due to environmental factors. Page 1 of 4 FOR TECHNICAL SUPPORT PLEASE CONTACT RELUME TECHNOLOGIES (248) 969-3800 WWW.RELUME.COM Rev. 10/22/13 INSTALLATION INSTRUCTIONS Relume RPSWP1 Rev Level _D__ Rev Date _10/22/13__ NOTE: This product must be installed in accordance with applicable national and regional electrical and building codes by qualified personnel. Approved for installation 4’ or higher above grade. TOOLS/HARDWARE REQUIRED: Hand drill with 1/8” bit Phillips screwdriver Flat screwdriver Hardware Kit consisting of 6 screws and 6 washers (included) (4) ½” #6 screws (or screws appropriate to install to existing junction box) (3) Wire nuts (not included) Liquid Tight Cord Grip (not included) 1. 2. Disconnect main power to the junction box at the installation location. Loosen the two enclosure screws on the right side of fixture (Figure 1) and open the two halves of the housing. 3. Figure 1 3. Carefully remove the two screws and two washers in the light engine (Figure 2). Page 2 of 4 FOR TECHNICAL SUPPORT PLEASE CONTACT RELUME TECHNOLOGIES (248) 969-3800 WWW.RELUME.COM Rev. 10/22/13 INSTALLATION INSTRUCTIONS Relume RPSWP1 Rev Level _D__ Rev Date _10/22/13__ Figure 2 4. Carefully lift light engine to access the electrical input line connections (black, white, green) as shown in Figure 3. Figure 3 For junction box mounting: 5. The bottom of the enclosure is to be mounted on the wall via a flush-mounted junction box. Installer must drill holes in housing to match those of the intended junction box. Drill them out using a power drill and a 1/8” drill bit. 6. Remove the rear coin plug. Install a liquid tight cord grip. Pull the input line wires from the junction box through the cord grip into the enclosure. Feed wires through cord grip. For Wall mounting with surface conduit: Page 3 of 4 FOR TECHNICAL SUPPORT PLEASE CONTACT RELUME TECHNOLOGIES (248) 969-3800 WWW.RELUME.COM Rev. 10/22/13 INSTALLATION INSTRUCTIONS Relume RPSWP1 Rev Level _D__ Rev Date _10/22/13__ 7. For surface conduit, remove the coin plug on the side of the enclosure appropriate for the incoming wiring (Figure 4). For series connection of multiple units, the plugs on both sides of the fixture will need to be removed with connections being made for both incoming wiring and wiring leading to the next fixture in the circuit. Figure 4 8. Drill out two holes in the rear half of the enclosure and two matching holes in the wall. Any of the hole locations shown in Figure 4 are appropriate for this use. 9. Using appropriate wall anchors (not provided); attach the enclosure to the wall. 10. Run a threaded end of the rigid surface-mount conduit into the hole in the enclosure and secure on the inside and outside of the enclosure with the appropriate nuts and seals (not provided). 11. Attach the line wires from the conduit to the wall pack power supply AC input wiring: white-white, black-black, green and yellow/green-ground. Secure the connections using wire nuts. All wire connections to be done inside of the Luminaire. 12. Once connections are made, carefully set light engine down on housing. Align holes and insert the 8 screws and 8 washers (two taken out and six in kit provided). 13. Remove plastic protective cover from face of light engine (Figure 2). 14. Close and refasten the two housing screws to complete the assembly. Page 4 of 4 FOR TECHNICAL SUPPORT PLEASE CONTACT RELUME TECHNOLOGIES (248) 969-3800 WWW.RELUME.COM Rev. 10/22/13