Document

advertisement
LIGHTPLANE 1 SUSPENDED - LP1SD/LP1SI
LIGHTPLANE 1 SURFACE MOUNT BACK - LP1SMB
LIGHTPLANE 1 SURFACE WALL WASHER - LP1SWW
Installation Guide
IMPORTANT SAFETY INSTRUCTIONS
When installing or using this suspended fixture basic safety precautions should be followed
Read ALL INSTRUCTIONS before installing fixture.
•This fixture is intended for installation in accordance with the National Electric Code
and Local and State Codes and must be installed by a licensed electrical contractor.
•DO NOT INSTALL FIXTURE LESS THAN 4IN FROM CEILING.
• THIS FIXTURE IS FOR INSTALLATION IN NON INSULATED CEILINGS ONLY.
•To prevent electrical shock, turn off electricity at fuse box before installing the fixture.
•Turn off power and allow fixture to cool down before adjusting position of lamps.
•Lift the entire fixture up to cables and insert cables into CABLE GRIPPER.
(The Cable Grippers will automatically hold the inserted cable)
• Wire the power cord with suitable wire nuts at the junction box and mount the power canopy
•Readjust the suspension cable as desired at the cable gripper to shorten and level the fixture.
• IMPORTANT - Cut Excess suspension cable slack at the grip lock after adjusted to desired height.
SAVE THESE INSTRUCTIONS
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 SUSPENDED - LP1SD/LP1SI
Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made
with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND
PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
TO BUILDING
SUPPORT
BLOCKING
DRYWALL
FASTENER
1/4-20 ROD
ALLTHREAD
SURFACE
CEILING
FITTING
CABLE
FITTING
BLOCKING
INSTALLATION
BRACKET
1/4-20 ALLTHREAD
INSTALLATION
INSTALLATION
CABLE SUSPENSION EXAMPLES
TO
BUILDING
POWER
REMOTE DRIVER
ENCLOSURE
CORD
DISCONNECT
CABLE
FITTING
SCREWS
CEILING
FITTING
SUSPENSION
KIT
CANOPY
BRACKET
CABLE
GRIPPER
SCREWS
ENDCAP
CANOPY
FINIAL
CEILING
FITTING
WIREBODY
CORD
SUSPENSION
KIT
CORD
GRIP
LENS
CABLE
GRIPPER
ENDCAP
INSTRUCTION:
1. TURN OFF POWER at fuse box before proceeding.
2. Remove REMOTE DRIVER ENCLOSURE and SUSPENSION KIT parts. Set parts aside.
3. If Joining multiple fixtures together Remove the
metal COVER and loosen the set screws on JOINING BAR hardware to extend them and secure.
Connect wires between fixtures using connectors
provided (if needed) and push excess wire into
fixtures. DO NOT PINCH WIRES BETWEEN THE PARTS.
Join segments together and secure joined fixtures
with the JOINING BAR Set Screws.
4. Install REMOTE DRIVER ENCLOSURE to building
structure and Attach BUILDING POWER using U.L.
approved wire connectors: Connect the neutral
(white) to the supply neutral, connect the line wire
(black) to the supply line wire. Fasten ground wire(s)
(Green) to ground wire. Push excess wires into the
REMOTE DRIVER ENCLOSURE.
5. Remove CABLE GRIPPER from SUSPENSION KIT and
connect it to WIREBODY (If Needed).
(DO NOT PINCH THE WIRES BETWEEN THE PARTS)
6. Install remaining CABLE SUSPENSION HARDWARE to
surface. Mounting method must support 50lbs.
Install CANOPY BRACKET to BUILDING WIRE JBOX.
7. While Supporting the WIREBODY, Attach SUSPENSION KIT cable to installed CABLE GRIPPER and
adjust height so fixture is level. Joined fixtures may
require adjusting JOINING BARS if connection
loosens during Installation.
8. Insert CORD through FINIAL, CANOPY, & CANOPY
BRACKET. Attach CORD to REMOTE DRIVER using
disconnect (Provided) or using U.L. approved wire
connectors.
LP1D-4 (44 78”)
SET
SCREW
COVER
LP1D-8 (88 7 8”)
CABLE
GRIPPER
SINGLE SUSPENDED FIXTURE
JOINING
BAR
JOINING MULTIPLE
SUSPENDED FIXTURES
LP1D-4 (45 3 4”)
LP1D-4 (44 1 4”)
LP1D-8 (90 1 4”)
LP1D-8 (88 1 4”)
MULTIPLE SUSPENDED FIXTURE
DO NOT CONNECT BUILDING POWER TO LED CORD.
PERMANENT LED DAMAGE,
RISK OF FIRE AND ELECTROCUTION WILL RESULT.
9. Push wires into JBOX & secure CANOPY with FINIAL.
(DO NOT PINCH THE WIRES BETWEEN THE PARTS)
10. Install COVERS and LENS(S)
11. Turn On Power
CABLE SPACING
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 SURFACE MOUNT BACK- LP1SMB
Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made
with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND
PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
TO BUILDING
SUPPORT
BLOCKING
DRYWALL
FASTENER
1/4-20 ROD
ALLTHREAD
SURFACE
BLOCKING
INSTALLATION
BRACKET
1/4-20 ALLTHREAD
INSTALLATION
INSTALLATION
CABLE SUSPENSION EXAMPLES
CORD
CORD
DISCONNECT
LENS
WIREBODY
REMOTE
DRIVER
ENCLOSURE
TO
BUILDING
POWER
COVER
SET
SCREW
COVER
SURFACE
MOUNT
BRACKET
INSTRUCTION:
1. TURN OFF POWER at fuse box before proceeding.
2. Remove REMOTE DRIVER ENCLOSURE. Set parts
aside.
3. If Joining multiple fixtures together Remove the
metal COVER and loosen the set screws on JOINING BAR hardware to extend them and secure.
Connect wires between fixtures using connectors
provided (if needed) and push excess wire into
fixtures. DO NOT PINCH WIRES BETWEEN THE PARTS.
Join segments together and secure joined fixtures
with the JOINING BAR Set Screws. Install COVERS.
4. Install REMOTE DRIVER ENCLOSURE to building
structure and Attach BUILDING POWER using U.L.
approved wire connectors: Connect the neutral
(white) to the supply neutral, connect the line wire
(black) to the supply line wire. Fasten ground wire(s)
(Green) to ground wire. Push excess wires into the
REMOTE DRIVER ENCLOSURE.
5. Attach SURFACE MOUNT HARDWARE using hardware (By Others). Mounting method must support
50lbs. USe blocking as needed.
6. While Supporting the WIREBODY, Insert Cord
through surface and attach WIREBODY to SURFACE
MOUNT BRACKET. Secure with set screw. Joined
fixtures may require adjusting JOINING BARS if
connection loosens during Installation.
7. Attach CORD to REMOTE DRIVER using disconnect
(Provided) or using U.L. approved wire connectors.
DO NOT CONNECT BUILDING POWER TO LED CORD.
PERMANT LED DAMAGE,
RISK OF FIRE AND ELECTROCUTION.
8. Push wires into JBOX & secure CANOPY with FINIAL.
(DO NOT PINCH THE WIRES BETWEEN THE PARTS)
9. Install LENS(S) if needed.
10. Turn On Power
JOINING
BAR
JOINING MULTIPLE
SUSPENDED FIXTURES
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 SURFACE WALL WASHER- LP1SWW
Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be
made with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND
PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
SET
SCREW
COVER
JOINING
BAR
JOINING MULTIPLE
SUSPENDED FIXTURES
INSTRUCTION:
1. TURN OFF POWER at fuse box before proceeding.
2. Remove REMOTE DRIVER ENCLOSURE. Set parts
aside.
3. If Joining multiple fixtures together Remove the
metal COVER and loosen the set screws on JOINING BAR hardware to extend them and secure.
Connect wires between fixtures using connectors
provided (if needed) and push excess wire into
fixtures. DO NOT PINCH WIRES BETWEEN THE PARTS.
Join segments together and secure joined fixtures
with the JOINING BAR Set Screws. Install COVERS.
4. Install REMOTE DRIVER ENCLOSURE to building
structure and Attach BUILDING POWER using U.L.
approved wire connectors: Connect the neutral
(white) to the supply neutral, connect the line wire
(black) to the supply line wire. Fasten ground wire(s)
(Green) to ground wire. Push excess wires into the
REMOTE DRIVER ENCLOSURE.
5. Attach SWIVEL MOUNT SURFACE BRACKET using
1/4-20 MOUNTING SCREW (By Others). Mounting
method must support 50lbs. Use blocking as
needed.
6. While Supporting the WIREBODY, Insert PLENUM CABLE
through surface and attach WIREBODY to SWIVEL
MOUNT SURFACE BRACKET. Secure with set screw.
Joined fixtures may require adjusting JOINING BARS
if connection loosens during Installation.
7. Attach PLENUM CABLE to REMOTE DRIVER using
disconnect (Provided) or using U.L. approved wire
connectors.
DO NOT CONNECT BUILDING POWER TO LED CORD.
PERMANT LED DAMAGE,
RISK OF FIRE AND ELECTROCUTION.
8. Install LENS(S) if needed.
9. Turn On Power
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
Download