EcoMod® Installation Instructions

advertisement
EcoMod® Series
Installation Instructions
! CAUTION
• All wiring should be done by a licensed electrician in accordance with state codes, local codes and National Electric Code (NEC) standards.
• Improper installation may result in serious injury and void warranty.
• Contains parts and assemblies susceptible to damage by electrostatic discharge (ESD).
Wiring
The standard fixture is supplied with a six foot cord and pigtail or junction box (JBOX option). Certain fixture configurations are supplied with connectors. These
connectors accept up to 12 AWG wire.
For fixtures with US cord: Green is ground, black is hot and white is common.
For fixtures with international cord: Green/yellow is ground, brown is hot and blue is common.
Incoming power cable diameter should be 3/8 to 1/2 inch for use with standard supplied cord grips.
Mounting
Fasten fixture with 3 x 1/2 inch (M12) bolts (not provided) through center hole and slots in harp assembly to a recommended torque of 45 ft-lb. Use mounting
dimensions shown in Figure 1. Attach near corner supports or use adequate subbase.
Figure 1: Dimensions for Standard Mounting Brackets
Contact factory for dimensions on custom mounting brackets.
EcoMod 150
12.50 in (318 mm)
5.98 in (152 mm)
2.99 in (76 mm)
3.36 in (85 mm)
20˚
0.56 in (14.2 mm)
0.56 in (14.2 mm)
EcoMod 300
22.15 in (563 mm)
15.00 in (381 mm)
7.50 in (191 mm)
3.36 in (85 mm)
10˚
0.56 in (14.2 mm)
EcoMod 450
0.56 in (14.2 mm)
23.58 in (599 mm)
11.79 in (299 mm)
16˚
2.63 in
(67 mm)
0.56 in (14.2 mm)
18.00 in
(457 mm)
5.44 in (138 mm)
9.00 in
(229 mm)
0.56 in (14.2 mm)
Phoenix Products Company Inc. 8711 West Port Avenue Milwaukee, WI 53224 USA
Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com
EcoMod® Series
Installation Instructions
Safety Cable Installation
Phoenix strongly suggests using a safety cable when installing EcoMod fixtures in port applications.
1. Locate a sturdy support structure for the safety cable to connect to. Please keep in mind that the safety cable is 36 inches (914 mm) long and must be able
to loop around a sturdy bar or bracket on the support structure.
2. Take the loop end (see Figure 2) of the cable and wrap it around the bar/ bracket on the support structure.
3. Take the eyelet end (see Figure 2) and insert into the loop, pulling it tight.
4. Insert 1/4-20 bolt (provided) into hole on side mount bracket (as shown in Figures 3 & 4). Then, add eyelet, lock washer and nyloc nut. Securely tighten nut
using wrench (not provided).
Figure 2
Figure 3
side mount
bracket
Figure 4
side mount bracket
loop end
safety cable
eyelet end
eyelet
bolt
lock washer
nyloc nut
Repair Parts List
Repair Part
Part Number
lens cover kit
010196.910
driver cover kit
010196.911
VS optic kit
010196.912
SP optic kit
010196.913
MF optic kit
010196.914
WF optic kit
010196.915
EM150 harp kit
010196.916
EM300 harp kit
010196.917
EM450 harp kit
010196.924
120-277V driver kit
010196.918
200-480V driver kit
010196.919
circuit board kit
010196.920
junction box kit
010196.922