EcoMod® Series Installation Instructions ! CAUTION • All wiring should be done by a licensed electrician in accordance with state codes, local codes and National Electric Code (NEC) standards. • Improper installation may result in serious injury and void warranty. • Contains parts and assemblies susceptible to damage by electrostatic discharge (ESD). Wiring The standard fixture is supplied with a six foot cord and pigtail or junction box (JBOX option). Certain fixture configurations are supplied with connectors. These connectors accept up to 12 AWG wire. For fixtures with US cord: Green is ground, black is hot and white is common. For fixtures with international cord: Green/yellow is ground, brown is hot and blue is common. Incoming power cable diameter should be 3/8 to 1/2 inch for use with standard supplied cord grips. Mounting Fasten fixture with 3 x 1/2 inch (M12) bolts (not provided) through center hole and slots in harp assembly to a recommended torque of 45 ft-lb. Use mounting dimensions shown in Figure 1. Attach near corner supports or use adequate subbase. Figure 1: Dimensions for Standard Mounting Brackets Contact factory for dimensions on custom mounting brackets. EcoMod 150 12.50 in (318 mm) 5.98 in (152 mm) 2.99 in (76 mm) 3.36 in (85 mm) 20˚ 0.56 in (14.2 mm) 0.56 in (14.2 mm) EcoMod 300 22.15 in (563 mm) 15.00 in (381 mm) 7.50 in (191 mm) 3.36 in (85 mm) 10˚ 0.56 in (14.2 mm) EcoMod 450 0.56 in (14.2 mm) 23.58 in (599 mm) 11.79 in (299 mm) 16˚ 2.63 in (67 mm) 0.56 in (14.2 mm) 18.00 in (457 mm) 5.44 in (138 mm) 9.00 in (229 mm) 0.56 in (14.2 mm) Phoenix Products Company Inc. 8711 West Port Avenue Milwaukee, WI 53224 USA Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com EcoMod® Series Installation Instructions Safety Cable Installation Phoenix strongly suggests using a safety cable when installing EcoMod fixtures in port applications. 1. Locate a sturdy support structure for the safety cable to connect to. Please keep in mind that the safety cable is 36 inches (914 mm) long and must be able to loop around a sturdy bar or bracket on the support structure. 2. Take the loop end (see Figure 2) of the cable and wrap it around the bar/ bracket on the support structure. 3. Take the eyelet end (see Figure 2) and insert into the loop, pulling it tight. 4. Insert 1/4-20 bolt (provided) into hole on side mount bracket (as shown in Figures 3 & 4). Then, add eyelet, lock washer and nyloc nut. Securely tighten nut using wrench (not provided). Figure 2 Figure 3 side mount bracket Figure 4 side mount bracket loop end safety cable eyelet end eyelet bolt lock washer nyloc nut Repair Parts List Repair Part Part Number lens cover kit 010196.910 driver cover kit 010196.911 VS optic kit 010196.912 SP optic kit 010196.913 MF optic kit 010196.914 WF optic kit 010196.915 EM150 harp kit 010196.916 EM300 harp kit 010196.917 EM450 harp kit 010196.924 120-277V driver kit 010196.918 200-480V driver kit 010196.919 circuit board kit 010196.920 junction box kit 010196.922 Product design and specifications are subject to change without notice. Phoenix Products Company Inc. 8711 West Port Avenue Milwaukee, WI 53224 USA Phone: +1 414.973.3300 Toll Free: 800.438.1214 Fax: +1 414.973.3210 www.phoenixlighting.com N5499893D 11.09.15