NY900 Series NEW YORK CITY APPROVED SPECIFICATION GRADE EDGE-LITE LED EXIT DESCRIPTION LED illuminated AC only and emergency exit models meet New York requirements. Architecturally pleasing fully universal signs for wall, ceiling, end mount and recessed applications. Model: Date: Accessories: Job Name: Type: FEATURES •Meets City of New York Emergency Code requirements •Attractive, specification-grade aluminum extrusion design •High clarity, optically true acrylic panels •Recessed and surface mount - Ceiling or wall •Custom legends or pictures available •ETL listed 90 minute emergency run time, 24 hour recharge time •Low voltage disconnect eliminates deep discharge •Brown-out, short circuit and voltage surge protection •UL recognized maintenance-free lead acid battery •Optional Guardian Self-Test/Self-Diagnostics (G2) available •NiMH battery standard with G2 option Custom legends available •Constant, uniform illumination by long-life, high intensity, red LEDs •Fully-illuminated 8" characters with 1" stroke •Field applicable chevrons provided •Standard finishes: Black, white and brushed aluminum •Complete fixture series meets American Recovery and Reinvestment Act of 2009 (ARRA) requirements and Buy American provisions WARRANTY Any component that fails due to manufacturer’s defect is guaranteed for a full 25 years. Lead acid batteries have a separate 1 year full and 4 year prorated warranty, and NiCad batteries have a 3 year full and 7 year pro-rated warranty. The warranty does not cover physical damage, abuse or acts of God. Manufacturer reserves the right to charge for such repairs if deemed necessary. ORDERING INFORMATION Example: NY902-U-WB-RM-ZC-BA Series Mounting Power Source Panel Color Arrow Configuration Finish Options (Factory Installed) NY902 = Single Face U = Universal Surface LB = AC Only RC = Red Letters/Clear Panel ZC3 = Zero Chevrons WH = White G22 = Self-Test/Self-Diagnostics WB = With Battery RW = Red Letters/White Panel BL = Black G2AA2 = G2 w/Audible Alarm NC2 = NiCad BA = Brushed Alum. DR = Damp Location Rated NY903 = Double Face R = Recessed WR1 = Wall Recessed RM = Red Letters/Mirror Panel FL = Flasher BZ = Buzzer FB = Flasher & Buzzer A1 = Fire Alarm Interface w/FL Notes A2 = Fire Alarm Interface w/FB 1 Single Face RC and GC panels only 2 G2 options come standard with NiMH batteries, not available with NiCad Accessories4 (Field Installed) 3 Includes field applicable chevrons ER1-KIT = 1’ Pendant Mount Kit 4 Order as separate line item, surface mount only ER2-KIT = 2’ Pendant Mount Kit CONSTRUCTION Housing Available in a powder coated white, black or brushed aluminum finish. Guardian Self-Test/Self-Diagnostics (Option: G2) The Guardian circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit. Surface Mounting Engineering grade aluminum extrusion with mounting canopy The purpose of this option is to provide visual signaling in response to a fault at the EXIT sign battery and/or battery charger. If a failure is detected, visual status will occur immediately via the CHARGER LED and/or the BATTERY FAULT LED. The LEDs will stay illuminated until the fault is corrected. Recessed Mounting Extruded aluminum housing supplied with galvanized steel adjustable bar hanger assembly. Panels Constructed of high quality, optically true, clear acrylic with beveled lettering for maximum light output. Double face panels are supplied with a mirror insert. Units are supplied with press-on directional arrows for placement in all applications. Stencil letters are 8” high with 1” stroke, with minimum of 100 ft viewing distance rating as required by UL924 standard. ILLUMINATION Illumination of the 900 Series is accomplished utilizing high-intensity, long-life red LEDs. LEDs provide excellent illumination while maximizing energy efficiency. As a maintenance-free solution, LEDs provide up to 100,000 hours of use without failure. ELECTRICAL Input Dual-voltage input 120 or 277VAC at 60Hz. Sealed Lead Acid Battery – SLA (With Battery Only) Exitronix sealed lead acid batteries are maintenance-free with a life expectancy of 5 years. Sealed lead acid batteries provide a relatively large power-to-weight ratio making them ideal for emergency applications. Lead acid batteries are constructed of a series of plates stacked with separators designed to optimize the efficiency and prolong the life of the battery. Lead acid batteries perform optimally in temperatures ranging from 59°F to 104°F (15°C to 40°C). Sealed Nickel Cadmium Battery – NiCad (Option: NC) Exitronix sealed NiCad batteries are maintenance-free with a life expectancy of 15 years. NiCad batteries offer high discharge rates and continue to perform in a vast temperature range from 32°F to 104°F (0°C to 40°C). NiCad technology provides long lasting, safe and reliable performance by utilizing the jelly-roll design and allows a NiCad cell to deliver a much higher maximum current than an equivalent size alternative battery. As a relatively larger area of the electrode is in contact with the active material in each cell, the internal resistance for an equivalent sized NiCad cell is lower which increases the maximum current that can be delivered. Sealed Nickel-metal Hydride - NiMH (With G2 option only) Exitronix NiMH batteries are maintenance-free with a life expectancy of 15 years. NiMH batteries perform optimally in temperatures ranging from 32°F to 104°F (0°C to 40°C). Emergency The 900 Series exit will operate for a minimum of 90 minutes during a loss of power with a 24 hour maximum recharge time for the battery. Brownout Circuit The brownout circuit monitors the flow of AC current to the unit and triggers the emergency lighting system once a set reduction of AC power occurs. This dip in the voltage will cause many fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred. The Guardian circuit also monitors the transfer circuit as well as performing automatic code compliance testing. The Guardian circuit will perform a 30 second discharge and self-test every 28-30 days. A 90 minute discharge and self-test is performed every 6 months. Flasher (Option: FL) When normal power is lost and the emergency unit goes into back up power mode, this unit will flash on and off – providing a highly visual signal as to emergency status. Audible Alarm (Option: BZ) When normal power is lost and the emergency unit goes into back up power mode, this unit will buzz – providing a highly audible signal as to emergency status. Flasher and Audible Alarm (Option: FB) When normal power is lost and the emergency unit goes into back up power mode, this unit will flash on and off while buzzing – providing a highly visual and audible signal as to emergency status. Fire Alarm Interface (Option: A1 or A2) Our fire alarm interface option ties into the building’s fire alarm system allowing for exits and emergency units to be triggered prior to loss of power. A1: Fire alarm interface with flashing A2: Fire alarm interface with flashing and audible alarm Two-Circuit Operation (Option: 2CI1, 2CI7 or 2CI17) Two circuit operation features for emergency lighting allows the dual input of power sources for units less battery (AC only). The purpose of this feature is to provide the compatibility of our emergency units in applications where inverters or alternate back up power sources are utilized. Custom and Specialty Legends (Option: SS) Exitronix offers a variety of standard specialty signs designed to provide directional or safety information in applications where clear and accurate delivery of information is required. Examples of specialty legends include: • “X-RAY IN USE” • “ON THE AIR” • Restroom Signage • “DO NOT ENTER” • “NO SMOKING” • “OCCUPIED” • "AREA OF RESCUE ASSISTANCE" with ADA Symbol on Left or Right Custom legends are also available - please call factory for details with questions. CONFORMANCE TO CODES AND STANDARDS The 900 Series is ETL listed and meets or exceeds the following: UL 924, NEC requirements and NFPA 101. DIMENSIONS Low Voltage Disconnect When the battery’s terminal voltage falls below predetermined levels, the lowvoltage circuit disconnects the emergency lighting load. The disconnect remains in effect until normal power is restored, preventing deep battery discharge and improving the life of the battery. The disconnect will also automatically reconnect the load circuit once the battery voltage returns to a normal value after charging. Test Button The test button is easy to locate and allows for manual verification of proper operation of the transfer circuit and emergency lamps. INSTALLATION Installs in minutes with easy-to read instructions and detailed diagrams. No special hardware or tools necessary. Internally housed components and battery. Damp Location Rated (Option: DR) Damp location rating ensures the fixture is designed to operate safely in outdoor locations that are protected from the direct elements. Damp location rated fixtures may be installed indoors. Products with damp location ratings are not designed to withstand constant or significant moisture or direct contact with water or steam. Made in the USA (Standard) 10” Many of our products can be produced or transformed to comply with the American Recovery and Reinvestment Act of 2009 (ARRA) requirements and Buy American provisions. These fixtures meet LEVEL 1 compliance when option is requested – please call factory for details with questions. 10” 10” Recessed Mount 10” Surface Mount Specifications are subject to change without notice. Installation must be performed in accordance with Barron Lighting Group installation instructions. 10800159 10/15 800.533.3948 • www.barronltg.com