Intelligent Software and Metering Devices Power Management Software WinPM.Net ™ Application Features: Web-Enabled Power Quality Analysis Data Acquisition Custom Graphics OPC SQL Database Alarm Notification Database Management Load Reporting ACCESS Energy Manager Application Features: Sub-Billing Management Custom Billing Templates Variable Rate Configurations Commercial/Industrial Use Web-Enabled Alarm Notification SQL Database Custom Graphics Meter Panels Application Features: Factory Pre-wired 1 to 12 meter options Key-lock Door available Communication available POWER, ENERGY and DEMAND Voltage/current: per phase, average Voltage/current: unbalance Power: real, reactive, apparent, power factor, frequency kW/kV Energy: bi-directional, import, export Energy: total, net Demand: block, sliding window Demand: thermal predicted POWER QUALITY ANALYSIS Sag/swell monitoring Symmetrical components: zero, negative, positive Transient detection, microseconds Harmonics (individual, even, odd, total) up to Sampling rate, maximum samples/cycle Flicker, harmonics to EN50160, IEC 6100-4-7 / 4-15 Configurable for IEEE 519-1992, IEEE 1159, SEMI/ITIC “Number of nines” uptime data (3 nines=99.9%) DATA and WAVEFORM LOGS Triggered by setpoint, schedule, or external signal Sequence-of-event logs, variable log depth Minimum/maximum logs Historical logs, maximum # of channels Waveform logs, maximum # of consecutive cycles Time-stamps, resolution in seconds Event Log GPS time synchronization COMMUNICATION PORTS and I/O ( ) = Optional RS-232/485 ports RS-485-only ports Ethernet ports Infrared optical ports PROFIBUS ports Built-in modems Modbus RTU Slave on serial, modem or infrared ports (If equipped with modem or infrared port) Modbus RTU Master on serial ports Modbus/TCP on Ethernet ports DNP 3.0 on serial, modem, infrared ports EtherGate™: 31 other meters accessible via RS-485 ModemGate: 31 other meters accessible via RS-485 MeterM@il®: data e-mailed from meter WebMeter®: on-board web server XML Analog inputs Analog outputs Digital status/counter inputs (standard/optional add-ons) Digital relay outputs (control/pulse) SETPOINTS, ALARMING and CONTROL Setpoints, minimum response time Math, logic, trig, log, linearization formulas Single- and multi-condition alarms Call-out on alarm REVENUE METERING ANSI C12.16 accuracy compliant ANSI C12.20 0.2 compliant EN50160 IEC 60687 0.2S compliant IEC 60687 accuracy class 0.5S compliant ANSI class 10 (5A nominal, 10A max) ANSI class 2, IEC 1/10 (1A nominal, 10A max) ANSI class 20, IEC 5/20 (5A nominal, 20A max) MV-90 on serial; Ethernet ports Time-of-use Transformer/line loss compensation PAC 3200 9200 9330 9340 9350 9360 THD only 400+ THD only 64 15th 32 63rd 128/3 9510 ADR 9510 9610/9610H 31st 64 63rd 128/185 63rd 256 65/17 127th/256th 512/1024 800 96 0.001 800 96 0.001 1 1 (1) 1 1 1 (1) 1 1 1 (1) 1 (1) (1) (1) 1 sec (1) 1 1 2/32 1 0.001 2 (1) 1 1 (1) 6/96 48 0.001 2 (1) 1 3 up to 185 0.1 1 (1) 800 (1) (1) (1) 1 1 2 and/or, >< 0.5S (4) (4) 4 4 (1) (2) (2) 1/(6) 1/(2) (4) (4) 4 4 (2) (2) 1/(6) 1/(2) 1 sec 1 sec 0.5S 0.5S 0.5S (4) (4) 8/8 7 (4) (4) 8/8 7 (4) (4) 8/8 7 ¹⁄₂ cycle ¹⁄₂ cycle ¹⁄₂ cycle 0.2S 0.2S Some features are optional. Refer to datasheets for allowable port configurations. Products meet or exceed the accuracy requirements of the standards listed; due to form factors, not all ANSI/IEC compliance tests may apply. Some products certified by third-party laboratory. Siemens Energy & Automation, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 info.sea@siemens.com ACCESS Technical Support 1-800-427-2256 www.sea.siemens.com/access © 2008 Siemens Energy & Automation, Inc. All Rights Reserved. Siemens is a registered trademark of Siemens AG. ACCESS and WinPM.Net are trademarks of Siemens Energy & Automation, Inc. Product names mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice. Order # PMPB-POST1-0208 2.5C0208CW Printed in USA