Load Shedding Overview Single Line Drawing Applications The RTS series of unique load shedding controls automatically reduce energy consumption of connected lighting loads by 25-50% (RTS-0-10V) or 100% (RTS-24,RTS-120,RTS-277) during peak hours or other specified conditions. A patent pending feature disconnects or dims lighting to deliver energy savings when they are required most. Demand Response: RTS can accept demand response signals and automatically disconnect any light fixture, or dim 0-10V light fixtures by 25 or 50%. Plug Load/Receptacle Control: RTS can connect to low voltage occupancy sensors to automatically switch receptacles on/off based on occupancy. Emergency Lighting: RTS can detect the loss of utility power and dim 0-10V light fixtures connected to an emergency inverter system by 25-50%. The RTS can be mounted in any junction box or most light fixtures by snapping into a 1/2” Knockout (K.O.) and is economically justified for any project. Load Shedding Signal RTS Load Shedding Circuit 24V or 120V or 277V Power Source LOAD RTS allows load to operate normally until load shedding signal changes position, then load is disconnected or dimmed, depending on model. All RTS models are UL listed and can be used in a variety of applications. Please consult pages 3-5 for additional information. Contact LVS for special application guidance or questions. Electrical Ratings to s in ” KO 1/2 h Hig p Sna Low ge ta Vol ut Inp age 1-7/8” 8” / 1-3 RTS-120 and RTS-277 (Type A Enclosure) 1 Enclosure Input Voltage Input Power RTS-120 Type A 120V AC 60Hz 1.2W RTS-277 Type A 277V AC 60Hz 1.2W RTS-24 Type B 24V AC/DC 1W Hig RTS-0-10V-24 Type B 120V AC 60Hz 0.2W 1” RTS-0-10V-24 Type B 277V AC 60Hz 0.2W RTS-0-10V-24 Type B 24V AC/DC 0.2W Quarter to scale t Vol 1-3/8” Model to s in ” 1/2 Low ge ta Vol ut Inp 20A Ballast 20A General Use 1800W Tungsten age olt hV KO p Sna Load Rating 1-3/8” 1” RTS-24 and RTS -0-10V (Type B Enclosure) UL ® UL LISTED Sinks up to 200 milliamp of 0-10V ballasts/drivers (100+ typical drivers) See pages 3-5 for application information on RTS models. 2 RTS-24 Load Shedding Controls Load Shedding Controls Application #1 Load Shedding (disconnect selected loads) Application #1: Switching/Load Shedding based on 0-10V Signal The RTS-24 can be used with an external transformer and dry contact from a BMS system (or other device such as time clock) to shed connected loads. An LVS TR-100 power supply can provide up to 250mA (enough for 6 RTS-24) but any 24V transformer or power supply (AC or DC) may be used. Some systems do not have a dry contact output, such as wireless systems or some photocells. RTS-120 and RTS-277 can accept input from the 0-10V line from a ballast/dimmer, when violet and gray are between 1-10V, relay is closed, 0-1V relay is open. Dimmer When load shed signal opens, RTS-24 de-energizes and sheds load. RTS-24 Neutral LOAD RTS-120/277 Neutral Load Shed Signal RED RED LOAD Hot YELLOW BLUE YELLOW Hot 24VAC 120V or 277V BLACK BLUE Hot Neutral 36 milliamps low voltage Application #2: Plug Load/Receptacle Control When Blue wire is energized (room occupied), RTS-24 energizes plug load. Power Pack RED Blue Red Black BLUE Hot ORANGE/BLACK WHITE 15 milliamps (high voltage) Only 1 milliamp (low voltage) Ballast When Hot/Neutral are energized and voltage between blue(+)/black(-) (violet/gray) is more than 1V , RTS relay is closed. Otherwise RTS relay is open. The RTS-120/277 can be used to control a receptacle (plug load) or lighting circuit using a DC input signal from an occupancy sensor with power pack or other DC supply. Power Pack RTS-120/277 Neutral RTS-24 LOAD GRAY Application #2: Plug Load/Receptacle/Lighting Control The RTS-24 can be used to control a receptacle (plug load) or lighting circuit using a 24V signal, such as from an occupancy sensor with 24V power pack. For sensors which use other voltages (such as 12V or 15V), see RTS-120 or RTS-277 on page 4. Neutral VIOLET RED BLUE BLACK Transformer BLUE LOAD Hot (Typical Power Pack Colors, Black = COM Blue = Control) YELLOW BLACK BLUE 36 milliamps low voltage Occupancy Sensor Note: Do not exceed power pack/transformer maximum output. Each RTS-24 requires 36 milliamps/1W. Typical sensor requires 50 milliamps (mA). Common power pack ratings are 100mA, 150mA or 250mA. 3 RTS-120 & RTS-277 RED YELLOW Blue Red Black RED BLUE (Typical Power Pack Colors, Black = COM Blue = Control) BLACK BLUE Hot Neutral ORANGE/BLACK WHITE Only 1 milliamp (low voltage) Occupancy Sensor 15 milliamps (high voltage) Note: RTS-120/277 can be used when power pack or dimmer control does not have sufficient power to supply RTS-24. RTS-120/277 requires less than 1mA to energize relay and can be used with any voltage power pack including 12V, 15V, 18V, 24V or other, up to 30VDC max. 4 RTS-0-10V 0-10V Dimming Load Shedding Controls Application #1 : Load Shedding (Demand Response) Dimmer Demand Response Signal RTS-0-10V-24 RED +24V ORANGE YELLOW GRAY BLUE BLACK COM VIOLET GRAY Ballast 10 milliamps low voltage Hot Neutral Normal Operation (Demand response contact closed): Load is controlled by dimmer Load Shedding Operation (Demand response contact open ): Load is dimmed at preset level Connect Gray for 75% brightness. Connect Blue & Gray for 50% brightness . Application #2 : Load Shedding (Emergency Lighting) Dimmer RTS-0-10V-120 or RTS-0-10V-277 BLACK/ORANGE UTILITY HOT UTILITY NEUTRAL WHITE ORANGE YELLOW GRAY BLUE VIOLET GRAY Ballast 10 milliamps high voltage Hot Neutral EPC Control Normal Operation: Load is controlled by dimmer Emergency Operation: Load is dimmed at preset level (50% or 75%). Connect Gray for 75% brightness. Connect Blue & Gray for 50% brightness. Note: Emergency Ballast Hot/Neutral should be connected to a UL924 Load Control Relay such as EPC-1 or EPC-A-1 to ensure they are switched on during a power interruption 5