PM3000 series power meters The essential monitor for understanding your electrical installation Simple and smart Reliable and accurate Order with ease, minimize stock Accurate information > 4 references to cover most installation requirements > Accuracy class 0.5S (IEC 62053-21/22) for active energy metering > Each meter supports 1P, 2P, 3P, and 3P+N wiring connections The PowerLogic PM3000 series power meters is a cost-attractive, feature-rich metering offer ideal for helping you better understand the true condition of your electrical installations . The meters are an excellent choice for implementing simple network applications to improve reliability, such as tracking real-time power conditions, monitoring network and equipment status, load trending, and basic alarming and event logging. The PM3000 series meters can also help you improve your efficiency by telling you where and when energy is consumed and letting you allocate costs to the appropriate department, process, or shift. With the PM3000 series power meters located in your main switchboard panel or main feeder panels, you can gather the information necessary to optimize your operation. > o Modbus RTU communication allows easy integration with power monitoring systems Data integrity > o Protected cages prevent contact to metallic part once cage is closed > o LED indicators provide visual status (i.e., energized & communicating) > o Separation of power (bottom) and communication (top) connections reduces risk of wrong wiring Top communications and I/O view with Modbus protocol Programmable digital output Pulse output LED indicator for energized status Current connectors for neutral wire shunting of current Backlit graphical display with configurable summary screen Power supply connectors Using with confidence > Large, backlit graphic display makes it easy to accurately read the descriptions of displayed values > Visual alerts on display help attract maintenance to potential issues > Intuitive keypad allows easy navigation for setup and display > Multi-language support via firmware download Anti-tamper seals For data security and personal safety Voltage connecters > Longer historical record helps create an accurate load profile for easier benchmarking and trending > Well protected for normal use: IP40 on front face, IP20 inside cabinet for remote transfer for WAGES counting, tariff control or external status > Internal memory for load profile (10 to 60 min) > Gain an accurate understanding of business expenses by allocating all energy-related costs > Double fixation offers greater stability, allows installation vertically or in high-vibration environments for communication status Programmable digital inputs > Anti-tamper sealing parts prohibit accessibility to all metering connections (voltage, current, DI/DO) Robust design LED indicator Measurement parameters alarms compatible with StruxureWare Power Monitoring software time periods for managing tariffs Digital inputs > Four-quadrant metering to differentiate energy > o Use the meter as a pulse counter for another meter (WAGES) Double fixation 4 > Plan network expansions based in accurate load profile information > o Monitor circuit breaker status or cabinet door opening; control up to 4 tariffs > Comprehensive electrical parameters (I, In, U, V, PQS, E, PF, Hz, THD) to help monitor network balance and overload behavior 100% > Reduce the duration of unplanned outages by ensuring that the right people are quickly notified > Total and partial kWh to discover consumption behavior Multiple tariffs 15 > Identify abnormal behavior and take corrective action before it becomes an issue > Manage double-source applications (e.g., utilities and fuel generator) > Help reduce utility penalties (active/reactive) Large intuitive screen display > Monitor network efficiency and reliability > THD monitoring (current, voltage) for simple power quality analysis Plastic aperture for firm placement > Implement actions designed to reduce energy consumption and promote energy efficiency Efficient operation > Target green technologies (delivered/received) to increase creepage distance and reduce risk of bad connection Optimize energy consumption and enable energy efficient practices > Collect and analyze all consumption data (WAGES) from each area for each type of load or circuit > Save last 32 days, last 20 weeks and last 13 months consumption data in separate registers Pluggable communications port • Features vary according to meter type > Compliance to regulations EN50470-3, IEC 61557-12, IEC 62053-21/22, IEC 62053-23 Integrate with ease, commision safely BENEFITS OF ENERGY MANAGEMENT APPLICATIONS > Save up to 4 different time slots to manage >>multiple tariffs (peak/off-peak, workday/weekend) > Control tariffs via digital inputs, internal clock or communication Digital outputs > For energy management: WAGES counting, remote reset, tariff control and energy pulse outputs > For installation monitoring: status input (circuit breaker trip or panel door opening), DO alarm for sound or light alert Multiple smart alarm > 16 alarms available > kWh alarm helps prevent a consumption above a given quota Compared with Acti 9 energy meters PowerLogic PM3000 power meters Function Self powered iEM 3100 iEM 3110 iEM 3115 iEM 3150 iEM 3155 iEM 3200 iEM 3210 iEM 3215 iEM 3250 iEM 3255 External power (80-477 V) Direct Measurement inputs (up to 63A) Measurement inputs through VTs 1 1 1 1 Four Quadrant Energy measurements PM 3250 PM 3255 1 0.5S 0.5S 0.5S 0.5S 0.5S 0.5S 0.5S 0.5S 0.5S Electrical measurements (I, V, P, ...) PM 3210 Logs 4 Multi-tariff (external control) 4 4 3 3 Digital inputs 3 4 2 3 2 3 4 4 3 3 1 Programmable digital outputs Pulse output • • • • • 3 4 2 3 2 1 4 3 4 4 5+ 5+ 5+ 5+ 1 2 1 2 Understand your installation, Optimize your operation PowerLogic PM3000 series power meters Industrial facilities Healthcare facilities Data centers Offices Hotels Meter order references Multi-tariff (internal clock) Measurement display (number of lines) Include the meters in main switchboard or subcabinets for: Measurement inputs through CTs (1A, 5A) Active Energy measurements class (Total and partial kWh) PM 3200 Applicable in numerous markets... >> Meter >> Reference >> Display >> PM3200 >> METSEPM3200 >> Display + Pulse Output >> PM3210 >> METSEPM3210 >> Display + Modbus >> PM3250 >> METSEPM3250 >> Display + Modbus + DI/DO + Log >> PM3255 >> METSEPM3255 Make the most of your energy S M Schneider Electric South Africa (Pty) Ltd Alarm 1 Modbus communication MID (legal metrology certification) 1 5 5 15 Reg. No. 1971/002841/07 Vat No. 4370101109 1 River View Office Park, Janadel Avenue, Halfway Gardens, Midrand Private Bag X139, Halfway House 1685, South Africa Tel. +27 (0) 11 254 6400 - Fax. +27 (0) 11 254 6640 http://www.schneider-electric.com/za Gain Energy insight with Powerlogic Power and Energy Management for ©2012 Schneider Electric. All Rights Reserved. Schneider Electric, Acti 9, and Make the most of your energy are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. 998-6351_GMA-GB Industry | Buildings | Data Centers & Networks