A-DDN074623++ PLYWOOD SIDING Section 07 46 29 Page 1 2013-07-10 GENERAL INFORMATION OF THE SPECIFICATION This specification describes the different type of wood sidings Tradition offered by GOODFELLOW INC as well as their related work. You can use this specification by adding or deleting the necessary sections for your project. It must also be modified so that the standards and codes apply in your country. The model can be chosen in our catalogue available on our web site. We only supply the wood, the trims, the finish, and the nails. The other accessories, such as furring or flashing must be supplied elsewhere. The numbers and specification references are based on the specification master of the Canadian National Master Specification (NMS). The responsibility of GOODFELLOW INC is limited to the present document. We are not responsible for all the modifications applied. This specification, modified or not, must be used with the approbation of a professional who assumes the entire responsibility. This document has no legal power if employed in its actual form and if not approved by the responsible professional. PART 1 – GENERAL 1.1 SECTION INCLUDES .1 Requirements for installation of finished wood siding such as [plywood], [hardboard] and [lumber siding]. 1.2 INSTALLED BUT NOT SUPPLIED PRODUCT SECTIONS .1 Section [07 62 00 - Sheet Metal Flashing and Trim]. 1.3 RELATED SECTIONS .1 Section [01 33 00 - Submittal Procedures]. .2 Section [01 74 19 - Construction/Demolition Waste Management and Disposal]. .3 Section [07 92 00 - Joint Sealing]. A-DDN074623++ PLYWOOD SIDING Section 07 46 29 Page 2 2013-07-10 1.4 REFERENCES 1.5 SUBMITTALS 1.6 QUALITY ASSURANCE SPEC NOTE: Edit the following for the specific project. .1 Canadian General Standards Board (CGSB). .1 CAN/CGSB-11.3-[M87], Hardboard. .2 CAN/CGSB-11.5-[M87], Hardboard, Precoated, Factory Finished, for Exterior Cladding. .3 CAN/CGSB-11.6-[M87], Installation of Exterior Hardboard Cladding. .4 CAN/CGSB-51.32-[M77], Sheathing, Membrane, Breather Type. .2 Canadian Standards Association (CSA International). .1 CSA B111-[1974(R2003)], Wire Nails, Spikes and Staples. .2 CSA O121-[08(R2013)], Douglas Fir Plywood. .3 CSA O151-[M1978(R1998)], Canadian Softwood Plywood. .4 CAN/CSA-Z808-[96], A Sustainable Forest Management System: Guidance Document. .3 Environmental Choice Program (ECP). .1 CCD-045-[95], Sealants and Caulking Compounds. .4 National Lumber Grades Authority (NLGA). .1 NLGA Standard Grading Rules for Canadian Lumber [2012]. .1 Product Data: Submit manufacturer's printed product literature, specifications and data sheet in accordance with Section [01 33 00 Submittal Procedures] [______]. .2 Samples: .1 Submit samples in accordance with Section [01 33 00 Submittal Procedures] [______]. .2 Submit duplicate [______] x [______] mm size profile specified. .3 Submit manufacturer's installation instructions. .1 Test Reports: certified test reports showing compliance with specified performance characteristics and physical properties. .2 Certificates: product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. .3 Pre-Installation Meetings: conduct pre-installation meeting to verify project requirements, manufacturer's installation instructions and manufacturer's warranty requirements. Comply with Section [______]. A-DDN074623++ PLYWOOD SIDING Section 07 46 29 Page 3 2013-07-10 1.7 WASTE MANAGEMENT AND DISPOSAL SPEC NOTE: Co-ordinate and edit the following paragraphs to meet and comply with the project's waste management workplan. .1 Separate waste materials for [reuse] [and] [recycling] [______] in accordance with Section [01 74 19 - Construction/Demolition Waste Management and Disposal] [______]. SPEC NOTE: The disposal of packaging waste into landfill site demonstrates an inefficient use of natural resources and consumes valuable landfill space. 1.8 DELIVERY STORAGE AND HANDLING .2 Remove from site and dispose of packaging materials at appropriate recycling facilities. .3 Collect and separate for disposal [paper] [plastic] [polystyrene] [corrugated cardboard] [______] packaging material [in appropriate on-site bins] [sorting office] for recycling in accordance with Waste Management Plan. .4 Divert unused metal materials from landfill to metal recycling facility approved by [Departmental Representative] [Engineer] [Consultant] [______]. .5 Divert unused wood materials from landfill to [recycling] [reuse] [composting] [______] facility approved by [Departmental Representative][Engineer] [Consultant] [______]. .6 Divert unused caulking material from landfill to official hazardous material collections site approved by [Departmental Representative] [Consultant] [______]. .7 Do not dispose of unused caulking materials into the sewer systems, into lakes, streams, onto ground or in locations where it will pose health or environmental hazard. .1 Carry out the transport, handling, and the material protection according to the section (01560). .2 Deliver the siding covered with a polypropylene tarpaulin and fixed at the base to protect from the weather. .3 Deliver and store the material such that the manufacturer’s stamp and label are conserved. A-DDN074623++ PLYWOOD SIDING Section 07 46 29 Page 4 2013-07-10 1. Submit the warranty according to the requirements in section (01300). 1.9 WARANTIES 2. Provide the architect or the owner the receipt indicating the sidings reception date. Also provide them a copy of the warranty certificate stipulating that the siding described in the present section is covered : - 50 years against rotting - 15 years on the finish - 60 years against the stainless steel nails corrosion , from the date of delivery. PART 2 – PRODUCTS 2.1 MATERIALS .1 Plywood Panels in compliance with CSA 0121 a) Lap & Lock: Goodstyle model provided by Goodfellow, [3/8] inch thick, [6] [8] [12] inch wide and 16 foot long. b) Panel [with grooves rainures at] [4’’ o.c][8’’ o.c] and dimensions of [3/8’’][7/16’’][19/32’’] by 4’ and [8’][9’][10’] long of Goodstyle model provided by Goodfellow inc. Finish: Colour number [colour number] [Premium] [Prestige] [Platinum] finish. SPEC NOTE: The panels can be painted or dyed with an unlimited choice of colour. Simply provide GOODFELLOW the desired colour and equivalence will be made. .2 Accessories in compliance with CSA 0121: a) Trim and Fascia Goodstyle model [3/4’’][1’’] x [1 ½’’] [2 ½’’] [3 ½’’] [4 ½’’] [5 ½’’] [7 ¼’’] [9 ¼’’] [11 ¼’’] provided by Goodfellow, 16’ long. Finish: Colour number [colour number] [Premium] [Prestige] [Platinum] finish. b) Trim and Fascia Goodstyle Preassembled corners 5/4’’ by [4’’] [6’’] provided by Goodfellow, 10’ long. Finish: Colour number [colour number] [Premium] [Prestige] [Platinum] finish. c) [Vented] [non vented] Soffit Goodstyle [3/8’’] [7/16’’] by [4’] [12’’] [16’’] provided by Goodfellow, [8’] [16’] long. Finish: Colour number [colour number] [Premium] [Prestige] [Platinum] finish. A-DDN074623++ PLYWOOD SIDING Section 07 46 29 Page 5 2013-07-10 d) Cedar shake with [straight edges] [staggered edges] Goodstyle model 7/16’’ by 11-3/4’’ provided by Goodfellow, 48’’ long. Finish: Colour number [colour number] [Premium] [Prestige] [Platinum] finish. .3 Exterior wall sheathing paper: to CAN/CGSB-51.32 [single ply] [laminated] [spunbonded olefin] [______] type [coated] [impregnated] [as indicated] [______]. SPEC NOTE: Goodfellow offers stainless steel nails, thermoplastic caulking compound and latex touch-up paint available in the colours of your choice. .4 Fasteners: nails to CSA B111, [hot galvanized steel] [aluminum] [copper] [stainless steel], sized as required, [smooth shank] [spiral] [or] [ring thread] type with [oval] [flat] [finishing] head [______]. .5 Sealants: [______][as prescribed in section 07 92 00]. 3.1 MANUFACTURER’S INSRUCTIONS .1 Compliance: comply with manufacturer's written data, including product technical bulletins, product catalogue installation instructions, product carton installation instructions, and data sheets. 3.2 INSTALLATION .1 Install hardboard to CGSB 11-GP-6M and manufacturers' instructions. .2 Install [one layer] [two layers] [______] sheathing paper horizontally by [stapling] [nailing] [______], lapping edges 100 mm. PART 3 - EXECUTION SPEC NOTE: Metal flashings for wood siding must be specified in Section 07 62 00 - Sheet Metal Flashing and Trim. .3 Install sill flashings, wood starter strips, inside corner flashings, edgings and flashings over openings. .4 Fasten wood siding in straight, aligned lengths to [framing and blocking] [furring] [sheathing] at [______] mm on centre maximum using [two] [______] nails at each fixing location. [Intermediate butt joints are not permitted] [______]. [Stagger butt joints not less than 800 mm and distribute evenly over wall faces] [______]. Cut butt A-DDN074623++ PLYWOOD SIDING Section 07 46 29 Page 6 2013-07-10 joints at 45 degrees [and for vertical siding slope to outside] [______]. Seal cut surfaces. [Apply [______] mm battens over vertical joints] [______]. 3.3 CLEANING .5 Fasten plywood siding so that edges are supported. Maintain 6’’ maximum space between the fasteners around the perimeter and 12’’ inside the wall. Fasten at least at 3/8’’ from the edge. [Apply [______] mm battens over vertical joints.] [Caulk vertical joints.] [______]. .1 Upon completion of installation, remove surplus materials, rubbish, tools and equipment barriers. END OF SECTION