Product Specification Sheet PLC Remote Service Switch Automatic Disconnect and Reconnect For TS2 System The Landis+Gyr Remote Service Switch (RSS) enables utilities to significantly improve operational efficiencies by eliminating the costs and labor associated with the disconnect or reconnect of electric services. Usable on residential Form 2S electromechanical and solid state meters, the 200-amp magnetic latching relay operates independently of the meter, all enclosed within a meter socket adapter or collar for complete house connects and disconnects. Using proven TS2 two-way power line carrier technology, operations, diagnostics and status verifications can be monitored within Command Center™, eliminating the need for costly on-site labor. Easily configured remotely or on-site, the Remote Service Switch is an easy, cost-saving addition to any residential infrastructure. Key Benefits: • External LEDs for onsite switch status indication; status can be changed onsite or remotely • Provides remote operation and immediate status verification from utility office • Operates independently of the meter and provides 200 amp residential whole house connect and disconnect • Remotely monitors both line and load voltage to verify switch status • Diagnostics available remotely or onsite by using the Handheld Programmer • Internal over-current protection for both safety and reliability www.landisgyr.com 800.828.4055 Remote Service Switch Product Specification Sheet Specifications Product Part Number FASY-0528-0001 Size 2.9"H x 6.9" diameter (4.35" high including lugs) Weight 2.25 pounds (1.02 kg) Operating Temperature -40°C to +75°C, ambient temperature Operating Voltage 240 VAC ±20% at 60 Hz Power Consumption 5 watts maximum standby Setup Method PLC or optical Compatibility Meter Form Voltage Class 2S 240 VAC 200 Standards Compliance Standard Description ANSI C 12.7-2005 Watt-hour Meter Sockets ANSI C 12.10 Electromechanical Watt-hour Meters ANSI/IPC-A-610 Acceptability of Electronic Assemblies FCC CFR Title 47 (Part 15, Subpart B) Radiated and Conducted Emissions IEC 61000-4-2 Electrostatic Discharge IEC 61000-4-4 Electrical Fast Transient IEC 61000-4-5 Surge (Combination) IEC 61000-4-6 RF Conducted Disturbance Immunity IEC 61000-4-8 Power Frequency Magnetic Field IEC 61000-4-9 Pulse Magnetic Field IEC 61000-4-11 Voltage Dips and Interrupts IEC 62000-4-12 Surge (100 kHz Ring Wave) EMI/RFI Immunity 3% Conducted Noise (400 Hz–15 kHz) across Operating Temperature Range IEC801-3 per ANSI C12.1 6436 County Road 11 Pequot Lakes, MN 56472 U.S.A Phone: 800.828.4055 • FAX: 218.562.4878 www.landisgyr.com © 2009 Landis+Gyr 6/19/09