Remote Service Switch

advertisement
Product Specification Sheet
PLC
Remote Service Switch
Automatic Disconnect and
Reconnect For TS2 System
The Landis+Gyr Remote Service Switch (RSS) enables utilities
to significantly improve operational efficiencies by eliminating the
costs and labor associated with the disconnect or reconnect of
electric services. Usable on residential Form 2S electromechanical
and solid state meters, the 200-amp magnetic latching relay
operates independently of the meter, all enclosed within a meter
socket adapter or collar for complete house connects and
disconnects. Using proven TS2 two-way power line carrier
technology, operations, diagnostics and status verifications can be
monitored within Command Center™, eliminating the need for
costly on-site labor. Easily configured remotely or on-site, the
Remote Service Switch is an easy, cost-saving addition to any
residential infrastructure.
Key Benefits:
• External LEDs for onsite switch status indication; status can be
changed onsite or remotely
• Provides remote operation and immediate status verification
from utility office
• Operates independently of the meter and provides 200 amp
residential whole house connect and disconnect
• Remotely monitors both line and load voltage to verify switch
status
• Diagnostics available remotely or onsite by using the Handheld
Programmer
• Internal over-current protection for both safety and reliability
www.landisgyr.com
800.828.4055
Remote Service Switch
Product Specification Sheet
Specifications
Product Part Number
FASY-0528-0001
Size
2.9"H x 6.9" diameter (4.35" high including lugs)
Weight
2.25 pounds (1.02 kg)
Operating Temperature
-40°C to +75°C, ambient temperature
Operating Voltage
240 VAC ±20% at 60 Hz
Power Consumption
5 watts maximum standby
Setup Method
PLC or optical
Compatibility
Meter Form
Voltage
Class
2S
240 VAC
200
Standards Compliance
Standard
Description
ANSI C 12.7-2005
Watt-hour Meter Sockets
ANSI C 12.10
Electromechanical Watt-hour Meters
ANSI/IPC-A-610
Acceptability of Electronic Assemblies
FCC CFR Title 47 (Part 15, Subpart B)
Radiated and Conducted Emissions
IEC 61000-4-2
Electrostatic Discharge
IEC 61000-4-4
Electrical Fast Transient
IEC 61000-4-5
Surge (Combination)
IEC 61000-4-6
RF Conducted Disturbance Immunity
IEC 61000-4-8
Power Frequency Magnetic Field
IEC 61000-4-9
Pulse Magnetic Field
IEC 61000-4-11
Voltage Dips and Interrupts
IEC 62000-4-12
Surge (100 kHz Ring Wave)
EMI/RFI Immunity
3% Conducted Noise (400 Hz–15 kHz) across
Operating Temperature Range
IEC801-3 per ANSI C12.1
6436 County Road 11
Pequot Lakes, MN 56472 U.S.A
Phone: 800.828.4055 • FAX: 218.562.4878
www.landisgyr.com
© 2009 Landis+Gyr 6/19/09
Download