HHD Heavy Duty Gymnasium High-Bay Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • Heavy duty gymnasium fixture comes standard with wireguard to protect lamps from activities & equipment damage. • Multi-lamp configuration allows for multi-level lighting suitable for various uses. • 1x4 available in 3 lamp cross section in T5HO or T8 configuration, 1x8 up to 6 lamps total. • 2x4 available in 6 lamp cross section in T5HO or T8 configuration, 2x8 up to 12 lamps total. • Optional sensor to reduce energy consumption in unoccupied spaces. • Excellent lumen maintenance (95% versus ~65% for typical metal halide). • Superior color rendering (82 CRI, versus 65-70 for metal halide). • Made In USA. Meets ARRA & Buy American requirements. Construction • Heavy duty 20 Ga. steel body • Multiple reflector options available for high and low-bay mounting and distribution applications • Standard hanging brackets and v-hangers included • Additional mounting hardware available • Standard 11 Ga. white wireguard • Weight: 1x4 9 lbs. 2x4 12 lbs. 1x8 18 lbs. 2x8 24 lbs. Certifications • UL 1598 listed for Canada and U.S. • Luminaires bear appropriate listing labels. • Emergency-equipped fixtures labeled UL 924. Electrical • • • • • • • • Application Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max) Lamp frequency: > 42 kHz Power Factor: >0.9% @ full load, 100V through 277V Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Current & Short Circuit with self-recovery Compliant to FCC 47CFR Part 18 Non-consumer Class A Sound Rating Optional emergency battery backup Optional step down transformer, drops 480 VAC to 277 VAC ORDERING INFORMATION – MODEL – – – • Open fixtures suitable up to 50°C/122°F • Suitable for use with most wired or wireless lighting control systems • Suitable for dry & damp locations: • Assemblies • Factory • Multi-media • Storage • Gymnasiums • High-Bay • Industrial • Low-Bay EXAMPLE HHD-1X8-6L-T8-UL2-HP-33IS-UE-WA-WW – – – – HHD Standard LAMP TYPE BALLAST FACTOR2 BALLAST GRADE T5HO T5HO T8 T8 LP Low Power HHDE Extended ST Standard Grade UE Ultra Efficient T8 Body Sensor Body SIZE 1x4 2x4 1x8 2x8 1x4 Nominal BALLAST VOLTAGE1 UL x Universal 2x4 Nominal 120-277 VAC 1x8 Nominal UHx 347-480 2x8 Nominal VAC LAMP QTY 2L 3L 4L 6L 8L 12L 2 Lamp 3 Lamp 4 Lamp 6 Lamp 8 Lamp (.75-.78) MP Medium Power (.85-.88) MN Neutral Power (.97-1.04) HP High Power (1.15-1.20) BALLAST STARTING3 IS Instant Start ISD Instant Start REFLECTOR MATERIAL EA Enhanced Aluminum 95% MM Micro Matte 91-93% WA White Aluminum Reflector 90-91% WIREGUARD WW 11 Ga. White Step Dimming PS Programmed Start 12 Lamp FOOTNOTES 1. Numeral indicates number of ballasts per fixture. 2. "MN" Ballast factor not for use with T8/ISD or T8/PS. 3. When using UL2, identify number of lamps powered by each ballast before starting method. Largest number first. Ex: 42PS = 6LT5HO. 4. Contact factory for additional cord & mounting options. 5. Numeral indicates number of lamps controlled, HBA is std. For Wattstopper, specify -WS after sensor option. Wireguard – WW – – OTHER HBTB Hanging Brackets + Top Mount Box TRS Step Down Transformer (Takes 480 to 277 VAC) – CORD PLUG4 C6 6' Cord, No Plug C6/ 6' Cord L715 & Plug (L7-15P) C6/515 6' Cord & Plug (515P) PQC15 15' Cord/ Quick Connect – OTHER LF Factory Lamps (Lamp spec elsewhere) EB Emergency Battery Backup 1PK Individually Boxed Fixture OCC SENSOR5 SHx Standard 360° View High-Bay Sensor RHx Rectangular Aisle View High-Bay Sensor SLx Standard 360° View Low-Bay Sensor RLx Rectangular Aisle View Low-Bay Sensor PLx Extreme Low 360° View Low-Bay Sensor Page 1/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HHD Heavy Duty Gymnasium High-Bay PHOTOMETRIC DATA PHOTOMETRIC DATA: HHD-1X4-3L-T5HO-UL1-MN-PS-ST-EA LUMINAIRE DATA Ballast Ballast Factor Lamp Fixture Lumens Watts Fixture Efficiency Mounting Shielding Angle Spacing Criterion Luminous Opening in feet INDOOR CANDELA PLOT HHD-1X4-3L-T5HO-UL1-MN-PS-ST-EA Heavy Duty Gymnasium High-Bay 454-MN-PS 1.00 F54 14192 177 95% Suspended 0° = 90 90° = 90 0° = 1.20 90° = 0.70 Length: 4.00 Width: 0.91 Height: 0.00 RCR RC 50 113 100 88 79 70 64 58 53 49 45 42 10 113 93 78 66 57 50 44 40 36 33 30 70 110 101 93 86 79 73 68 63 59 56 53 %Lamp %Fixt 80 5062 7596 11899 14192 34 51 79 95 36 54 84 100 70 4147 60 6220 50 8294 0 10 70 30 113 96 82 71 63 56 50 45 41 38 35 Lumens 0-30 0-40 0-60 0-90 20 30 AVG. LUMINANCE (Candela/Sq. M.) 40 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ 80 70 113 104 95 88 81 75 70 65 61 57 54 Zone 2073 COEFFICIENTS OF UTILIZATION (%) RW 0 1 2 3 4 5 6 7 8 9 10 ZONAL LUMEN SUMMARY 90 50 110 98 87 77 69 63 57 52 48 45 41 50 30 110 94 81 71 62 55 50 45 41 38 35 10 110 91 77 65 57 50 4 40 36 33 30 50 105 94 83 74 67 61 55 51 47 43 41 30 105 91 79 69 61 54 49 44 40 37 34 Average Luminance Angle Luminaire 0 10 105 89 75 64 56 49 44 39 36 33 30 0 95 81 70 60 52 46 41 37 34 31 28 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90 8293 8130 7932 7856 7640 7289 6796 6332 5784 5185 4519 3760 2974 2269 1593 1053 570 211 8293 8216 7913 7540 7048 6402 5612 4856 4104 3412 2810 2296 1806 1379 1011 693 408 128 8293 7998 7517 6753 5820 4781 3996 3429 2983 2632 2250 1845 1517 1248 1010 684 326 62 8293 7933 7211 6073 4821 4052 3490 3182 2824 2394 2019 1779 1507 1320 981 569 263 32 8293 8003 7092 5838 4660 3894 3444 3144 2717 2321 1996 1783 1518 1350 932 538 241 23 PHOTOMETRIC DATA: HHD-2X4-6L-T5HO-UL2-MN-42PS-ST-EA LUMINAIRE DATA Ballast Ballast Factor Lamp Fixture Lumens Watts Fixture Efficiency Mounting Shielding Angle Spacing Criterion Luminous Opening in feet INDOOR CANDELA PLOT HHD-2X4-6L-T5HO-UL2-MN-42PS-ST-EA Heavy Duty Gymnasium High-Bay 454-MN-PS, 254-MN-PS 1.00 F54 28156 351 94% Suspended 0° = 90 90° = 90 0° = 1.30 90° = 1.16 Length: 4.02 Width: 1.67 Height: 0.00 RCR RC 50 112 99 88 78 70 63 57 52 47 43 40 10 112 93 77 65 56 49 43 38 34 31 28 70 109 101 92 85 78 72 67 62 58 54 51 %Lamp %Fixt 80 9149 14648 24120 28157 31 49 80 94 33 52 86 100 70 6017 60 9025 50 12033 0 70 30 112 96 82 71 62 55 49 44 39 36 33 Lumens 0-30 0-40 0-60 0-90 10 20 30 AVG. LUMINANCE (Candela/Sq. M.) 40 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ 80 70 112 103 95 87 80 74 68 64 59 56 52 Zone 3008 COEFFICIENTS OF UTILIZATION (%) RW 0 1 2 3 4 5 6 7 8 9 10 ZONAL LUMEN SUMMARY 90 50 109 97 86 76 68 62 56 51 47 43 40 50 30 109 94 81 70 61 54 48 43 39 36 33 10 109 91 76 65 56 48 43 38 34 31 28 50 104 93 83 74 66 60 54 49 45 42 39 30 104 91 78 68 60 53 47 43 39 35 32 0 10 104 88 74 64 55 48 42 38 34 31 28 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 0 94 81 69 59 52 45 40 35 32 29 26 Average Luminance Angle Luminaire 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90 11600 11512 11428 11318 10843 10568 10030 9588 8718 7958 7108 6079 5060 4114 3143 2146 1238 427 11600 11805 11658 11588 11181 10639 9946 9337 8709 7756 6726 5692 4590 3430 2337 1415 659 133 11600 11948 11833 11364 10798 10520 10134 9062 7706 6672 5767 4542 3276 2384 1620 877 271 27 11600 11937 11791 10998 10930 10608 9276 7924 7250 6263 4764 3554 2852 2065 1279 600 103 30 11600 12033 11562 11158 11197 10489 8839 7841 7210 5897 4319 3465 2710 1914 1146 509 64 29 Page 2/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HHD Heavy Duty Gymnasium High-Bay EXISTING VS. PROPOSED HIGH-BAY SYSTEM Existing High-Bay System MH250 MH320PS MH400 HPS400 Proposed High-Bay System Lamp Quantity & Type 1 1 1 1 Std. MH250 PS MH320 Std. MH400 Std. HPS400 Lamp Quantity & Type Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens 20,500 31,700 38,000 50,000 58% 62% 58% 70% 11,890 19,654 22,040 35,000 11,890 19,654 22,040 35,000 Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens 2,950 2,950 2,950 90% 90% 90% 2,655 2,655 2,655 5,310 10,620 15,930 2L-T8 Plus 4L-T8 Plus 6L-T8 Plus 2 4 6 F32T8/841 F32T8/841 F32T8/841 8L-T8 Plus 8 F32T8/841 2,950 90% 2,655 2L-T5HO 2 FP54T5HO 5,000 93% 4,650 4L-T5HO 4 FP54T5HO 5,000 93% 6L-T5HO 6 FP54T5HO 5,000 8L-T5HO 8 FP54T5HO 5,000 EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture 1.00 1.00 1.00 1.00 0.75 0.75 0.75 0.75 8,198 14,741 16,530 26,250 EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 1.49 1.49 1.49 0.62 12,171 20,119 22,561 18,080 295 368 458 464 S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 8,007 15,874 24,647 73 147 218 294 1.15 1.14 1.18 0.90 0.90 0.90 5,496 10,896 16,918 1.62 1.62 1.62 21,240 1.14 0.90 21,792 1.62 31,749 9,300 1.00 0.92 8,556 1.62 12,465 117 4,650 18,600 1.00 0.92 17,112 1.62 24,930 234 93% 4,650 27,900 1.00 0.92 25,668 1.62 37,395 351 93% 4,650 37,200 1.00 0.92 34,224 1.62 49,860 468 (1) EOL = End of life (2) S/P Ratio = Scotopic to Photopic Lumens (3) Net EOL Lumens = EOL Lumens Per Fixture x (S/P).78 [.78 exponent] *Lamp/ballast system values shown are a general reference intended to supply a quick comparison of several common lamp/ballast systems, the associated energy consumption, and net lumen output. *Values shown are based on normal operating temperatures (25°C T8 and 35°C T5) and at 277 volts. *Fixture efficiency percentages are generally representative of each system type, actual values will vary. *There are many operating variables that affect system output, in addition to rating variances from brand to brand. *All T8 electronic ballast values shown are based on Ultra Efficient (aka 3rd Generation) T8 ballasts. *All T5 and T8 lamp values shown are for basic grade lamps. Extended life and higher lumen lamp types are available. *In addition to those shown, there are a wide variety of systems to choose from, each with distinct features and cost points. *Please consult the lamp/ballast manufacturer's catalogs for the detailed information required to model your system. MOUNTING OPTIONS - SUSPENDED HB 2-POINT HANGING BRACKETS Included HB 2-POINT HANGING BRACKETS Included V-HANGER Included V-HANGER Included GRIPPLE LOOP Order Separately TOP BOX FOR POWER SUPPLY Optional 4" GRIPPLE LOOP Order Separately 4" 2" Page 3/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HHD Heavy Duty Gymnasium High-Bay FIXTURE DIMENSIONS END VIEW 1X4-2 LAMP T5 SIDE VIEW 1X4 13.000" 52.000" 5.125" 5.125" PLAN VIEW 1X4 13.000" 52.000" END VIEW 2X4-4 LAMP T8 END VIEW 2X4-6 LAMP T5 20.000" 20.000" 5.320" 5.320" PLAN VIEW 2X8 101.000" 20.000" *Drawings N.T.S. Page 4/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com