PANELBOARDS 7 Panelboards Type 1 P1 Panelboard Modifications and Additions Enclosures List Price $ Description 6" end gutter . . . . . . . . . . . . . 2" side gutter . . . . . . . . . . . . . Barrier in gutter (add to extra gutter price) . . . . . . . . . . . . 24" wide . . . . . . . . . . . . . . . . ....... ....... 220. 205. ....... ....... 175. 205. Hinged trims . . . . . . . . Piano hinged trims . . . Door-in-door trims . . . Screw to the box trims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145. 150. 320. 145. Trim mounted devices . . . . . . . See page 7–66 • Pilot lights • Toggle switches • Push buttons (Devices mounted to be wired to the trim should also have hinged trim specified) Painted boxes . . . . . . Custom colors . . . . . . Increase gauge trims and boxes . . . . . . . Stainless steel trims and boxes, Type 1 . Aluminum trims and boxes, Type 1 . ..... See page 7–66 . . . . . See painted boxes ..... See page 7–66 ..... See page 7–66 ..... See page 7–66 Meters (Contact sales for pricing and application engineering for space requirements) Panel Skirts See page 7-67 Special Locks TEY . . . . . . . . TEU1 . . . . . . . Cat 60 . . . . . . LL803 . . . . . . LL806 . . . . . . Yale 47 (NYC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205. 225. 205. 205. 225. 375. Panel Modifications Main Bus Catalog Amp Ratings Number* 125A 250A 400A Copper (tin pltd.) C 350. 230. 230. Bus mounted TVSS. . . . . Service Entrance Label see section 9 Switch Type Type P1 Panelboards are factory labeled suitable for use as service entrance equipment when NEC requirements are met. A panelboard cannot have more than six main disconnects, unless it is a lighting and appliance branch panelboard. Lighting and appliance branch panelboards are limited to two main disconnects. Grounding of Panelboards Ground Bars except for brazed to box are shipped with the panel interior factory mounted. • Non-Insulated Equipment Ground Bar – Std. • Copper Non-Insulated Ground Bar . . . . . 35. • Al Insulated Equipment Ground Bar. . . . 35. • Cu Insulated Equipment Ground Bar . . . 65. • Ground Bar Brazed to Box . . . . . . . . . . 215. (recommended for painted boxes) Shunt Trip on Main or Branch BL, BLH, HBL, BQD as branch only. BL, BLH, HBL uses 1” unit space for shunt trip as a branch device. All others may be used on mains or subfeeds. See breaker section for list price adders. QJ2, QJ2-H, QJH2, HQJ2H, ED4, ED6, HED4, HED6, HHED6, FXD6, HFD6, JXD6, JD6, HJD6, HJXD6 See breaker section for pricing on the following options • Handle blocks • Handle locks • Aux. Contacts • UVR 920 911 LEN Modification Mounts in 23” relay cabinet as a main only ≤ 150 AMPS mounts in 23” relay cabinet as a main only >150 AMPS not available 30A mounts in 23” relay cabinet as a main only Feed-Thru Lugs Cannot be used in conduction with TVSS or subfeed breakers Ampere List Rating Price $ Type Al/Cu Lay-in 165. Mechanical Cu Lay-in 250 325. Mechanical Al/Cu 250. Compression Al/Cu 435. AWG Mechanical 400 435. Cu 515. Al/Cu Compression Time Clocks Time clocks may be mounted in a 23" enclosure to be cable connected to the panel. Sangamo, Tork or Paragon time clock can be supplied. List Price $ Description Time Clock (1- or 2-pole, single or double throw contacts; 3-pole, single throw) 277V maximum with plain dial Astronomical dial An omitting device Reserve power or carryover Space and mounting provisions only 945. 190. 65. 2170. 475. Remote Switches Modifications (See page 7-65) Accessories on 1” pole breakers (BL, BQD, ED) will take unit space. Discount Schedule T 7-14 Connector Range (1)—#6 AWG350 kcmil (1)—#6 AWG350 kcmil (1)—#6 AWG350 kcmil (2)—#3/0 AWG250 kcmil or (1)—#3/0 AWG600 kcmil (2)—#3/0 AWG250 kcmil or (1)—#3/0 AWG600 kcmil (1) 400—600 kcmil Note: Specify copper or aluminum cable. Remote Control Switches 480V AC max. mounted in a 23” enclosure to be cable connected to the panel. * “C” represents “A” in the 11th digit of the catalog number. Branch and Main Breaker and Accessories Application for Remote Switch 2005 Electrical Distribution Products Panelboards 7 Type 1 P1 Panelboard Connector Modifications Style Amp Rating 125 MLO 250 400 Breaker Type Compression Connectors N/A (1) #4 AWG - 350 kcmil N/A 90. 70. 70. 70. None 135. 105. 105. 85. (1) #12-1/0 AWG Box must go to 24” wide 100. 75. 75. 75. (1) 250-600 kcmil or (2) #3/0 AWG - 250 kcmil 125 Main Breaker ED4, ED6, HED4 HHED6, CED6 List Price Adder $ 3 Phase/ 3 Phase/ 1 Phase/ 1 Phase/ 4 Wire 3 Wire 3 Wire 2 Wire Box Height Addition 225 QJ2, QJH2, QJ2H (1) #6 AWG - 350 kcmil Cu or AI Box must go to 24” wide for all breakers 195. 155. 155. 155. 250 FXD6, HFD6, CFD6 (1) #6 AWG - 350 kcmil Cu or AI Box must go to 24” wide for all breakers 195. 155. 155. 155. NOTE: Standard compression lugs used for P1 panels are range taking lugs and may require a particular crimping tool to accommodate the range. Consult factory for information. 200% neutral not available with compression lugs. Enclosure Modifications List Price Adder $ Description NEMA 3R enclosure s NEMA 3R/12 enclosure s Gasket between trim and box (Type 1) Panel Width 20" Panel Width 24" 760. 760. 600. 1045. 1045. 795. NEMA-4—Water Tight, Dust Tight, Steel Enclosure (consult plant for actual enclosure size) Box Height (inches) Enclosure Size H W D List Price Adder $ 32 38 44 56 62 68 32 38 44 56 62 68 5.75 5.75 5.75 5.75 5.75 5.75 3750. 4725. 5850. 14400. 18200. 22000. 20 20 20 20 20 20 Additional Enclosure Modifications Description Strip Heaters List Price $ 790. Humidstat Control 1390. Thermostat Control 1390. NEMA-4X—Water Tight, Dust Tight and Corrosion Resistant (consult plant for actual enclosure size) Box Height (inches) 32 38 44 56 62 68 Enclosure - Stainless Steel & Steel with Epoxy Coating H W D 32 20 5.75 38 20 5.75 44 20 5.75 56 20 5.75 62 20 5.75 68 20 5.75 Enclosure - Fiberglass Size (inches) H D W 36 24 8 48 36 12 48 36 12 60 36 12 66 36 12 72 36 12 List Price $ 8990. 10700. 14000. 17950. 21000. 24300. Remote Switches Modifications (See page 7-65) Application for Remote Switch Switch Type 920 911 LEN Modification Mounts in 23” relay cabinet as a main only ≤ 150 AMPS mounts in 23” relay cabinet as a main only >150 AMPS not available 30A mounts in 23” relay cabinet as a main only 2005 Electrical Distribution Products Discount Schedule T 7-15 PANELBOARDS Compression Lugs