Pharmaceutical Refrigerator Operation Manual LR051WWW/0 LR051WWG/0 LR031WWW/0 LR031WWG/0 Read the Operation Manual carefully before using your appliance. Keep the Operation Manual in a safe place. Appearance, color and layout of the door may vary. The Scope of the Product Application: Pharmaceuticals, medicine and other related products which need a storage environment of 2 -8 . 08/15 162346 Rev A. LR051WWW/0 LR051WWG /0 118L LR031WWW/0 LR031WWG/0 68L Solid door Names of components Shelves/Bins Cooling Type Solid door 1 2 Forced air cooling 3 1 1 101.4 lbs/46kg Exterior Dimensions W× D× H 90.4 lbs/41kg 597 ×645 ×835mm 23.5 ×25.4 ×32.9(in) Noise Electric Shock Prevention Type Foaming Cabinet 83.8 lbs/38kg 83.8 lbs/38kg 495 ×580 ×660mm 19.5 ×22.8 ×26.0(in) 30dB(A) CP/IP Climate Type The connecting method of power wire 4 Y NOTE: Climate Type 4 means the temperature is +30 LR051WWW/0 , the relative humidity is 55%. LR051WWG /0 LR031WWW/0 LR031WWG /0 Power Supply(V/Hz) 115~/60 115~/60 Electrical Current(A) 1.05 0.65 Power(W) 160 84 Accessories LR051WWW/0 LR051WWG /0 LR031WWW/0 LR031WWG /0 Please take care of the key,if lost ,please contact the seller. 08/15 162346 Rev A. Correct Operation right indicates carefulness. Unplug the power plug indicates prohibition. indicates provisions. Do not disassemble 7) Do not load excessive material in the appliance , which has been thoroughly tested and assured as operational. K eep ground wire connected Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. This operation manual should remain attached to this appliance. Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. Do not damage the refrigerant circuit. This warning is only applicable for appliances with refrigerating circuits which are accessible by the user. Do not use electrical appliances inside the food storage compartments of the appliance unless they are of the type recommended by the manufacturer. The appliance must be positioned so that the plug is accessible. The appliance must be placed on a solid and flat surface, or excessive vibration and noise may be produced when the appliance in operation. If your cabinet is to be discard,you must remove the door and leave the shelves in place. This will reduce the possibility of danger to children. And the flammable foaming needs to be diposed by professional persons. 08/15 162346 Rev A. Operation instructions Warning . U sing the refrigerator in the open air is Make sure no volatile material or forbidden when wet with rain or water, it may cause electric leakage or shock. The refrigerator shall be installed by qualified engineering and technical personnel or maintenance personnel only, and individual installation of it may result in gas, liquid or electric leakage or electric shock. flammables are allowed to be placed into the refrigerator; or otherwise, it may result in explosion or fire. S ee to it that all parts of the appliance be firmly installed on the solid ground; or otherwise, the refrigerator is prone to dump or overturn for unnecessary personal injury. The refrigerator shall not be placed on wet or water accessible sites so that no damages to insulation materials or electric shock can be occurred. See to it that stipulated private power supply is used; the usage of branch outlet may result in fire. See to it that power plug is firmly into the socket after dust cleaning on the latter, for a dusty socket or an incorrect way of plugging may trigger fire. Use an earthed socket to avoid electric shock, in case of no such a socket, the earthed devices shall be equipped by qualified engineering and technical personnel. The plug of the refrigerator shall be readily available after its installation. No earthing of the refrigerator is allowed via gas pipe, general water supply pipe, telephone line or lightening meter, which may trigger electric shock under incomplete conditions of earthing. No metal material such as iron pin or wire is permitted to be stuffed into the vents, the channel port or exhaust port for air circulation inside the refrigerator; or otherwise, the unexpected running of the moveable parts may cause electric shock or personal injury. P lease keep the article inside at least 20mm away from the cabinet back wallĘ˝ Users must not dismantle, repair or modify the equipment. Such improper operations may result in fire or personal injury. Unplug the power plug before repairing, maintenance or checking of the refrigerator to avoid electric shock or personal injury. No direct sprinkle of water on the refrigerator is allowed, and a wet refrigerator may trigger electric shock or short circuit. No private dismantle or reinstallation of the refrigerator is permitted, and unqualified work of such kind may trigger fire or personal injury. Unplug the power plug when failure occurred, and lasting abnormal running of the appliance may result in electric shock or fire. The safe usage sites of the refrigerator is needed when the materials handled are poisonous, harmful or radioactive, and improper usage of it may pose unhealthy impacts on you and the environment. The wastes of the refrigerator need to be disposed by specialized personnel, no arbitrary movement of it is allowed; or otherwise, events of kids being shut in it may occur. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. For temperature abnormalities or alarming, if any, no matter whatever reason, articles in the refrigerator shall be transferred as soon as possible so as to avoid your losses. Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. CP/IP foaming materials are flammable, need professional processing. Do not attempt to use the handle to lift or move the unit to avoid damaging the freezer or injuring personnel. 08/15 162346 Rev A. Names of components Operation instructions Panel The control panel only can display one sensor error,when the sensor error happens .Led display "E1",and alarm at the same time. The refrigerator will keep working according to the defect safety model,and you should put the stored goods in another refrigerator as soon as possible, and contact the after-sales department quickly. Levelers Panel In order to see the stored goods clearly, a LED light has been installed in the cabinet. You can control light "on" or "off" by "light" button to save energe(Non-functional on the solid door models) please turn off the light after observing the stored goods in the refrigerator. Note: After installation, the power plug must be easy to reach. In case of emergency, it is easy to uplug. Nothing should block the ventilation. 08/15 162346 Rev A. Operation instructions Shelf Goods can be conveniently stored on the shelves. Foot It is convenient to adjust the height of unit. 5. (Non-functional on the solid door models) release release release release release 08/15 162346 Rev A. Installation Transportation and relocation requirement:clamp truck or forklift truck. 08/15 162346 Rev A. Installation Transportation and relocation requirement:clamp truck or forklift truck. 08/15 162346 Rev A. Operation instructions Shelf Goods can be conveniently stored on the shelves. Foot It is convenient to adjust the height of unit. 5. (Non-functional on the solid door models) release release release release release 08/15 162346 Rev A. Names of components Operation instructions Panel The control panel only can display one sensor error,when the sensor error happens .Led display "E1",and alarm at the same time. The refrigerator will keep working according to the defect safety model,and you should put the stored goods in another refrigerator as soon as possible, and contact the after-sales department quickly. Levelers Panel In order to see the stored goods clearly, a LED light has been installed in the cabinet. You can control light "on" or "off" by "light" button to save energe(Non-functional on the solid door models) please turn off the light after observing the stored goods in the refrigerator. Note: After installation, the power plug must be easy to reach. In case of emergency, it is easy to uplug. Nothing should block the ventilation. 08/15 162346 Rev A. Operation instructions Warning . U sing the refrigerator in the open air is Make sure no volatile material or forbidden when wet with rain or water, it may cause electric leakage or shock. The refrigerator shall be installed by qualified engineering and technical personnel or maintenance personnel only, and individual installation of it may result in gas, liquid or electric leakage or electric shock. flammables are allowed to be placed into the refrigerator; or otherwise, it may result in explosion or fire. S ee to it that all parts of the appliance be firmly installed on the solid ground; or otherwise, the refrigerator is prone to dump or overturn for unnecessary personal injury. The refrigerator shall not be placed on wet or water accessible sites so that no damages to insulation materials or electric shock can be occurred. See to it that stipulated private power supply is used; the usage of branch outlet may result in fire. See to it that power plug is firmly into the socket after dust cleaning on the latter, for a dusty socket or an incorrect way of plugging may trigger fire. Use an earthed socket to avoid electric shock, in case of no such a socket, the earthed devices shall be equipped by qualified engineering and technical personnel. The plug of the refrigerator shall be readily available after its installation. No earthing of the refrigerator is allowed via gas pipe, general water supply pipe, telephone line or lightening meter, which may trigger electric shock under incomplete conditions of earthing. No metal material such as iron pin or wire is permitted to be stuffed into the vents, the channel port or exhaust port for air circulation inside the refrigerator; or otherwise, the unexpected running of the moveable parts may cause electric shock or personal injury. P lease keep the article inside at least 20mm away from the cabinet back wallĘ˝ Users must not dismantle, repair or modify the equipment. Such improper operations may result in fire or personal injury. Unplug the power plug before repairing, maintenance or checking of the refrigerator to avoid electric shock or personal injury. No direct sprinkle of water on the refrigerator is allowed, and a wet refrigerator may trigger electric shock or short circuit. No private dismantle or reinstallation of the refrigerator is permitted, and unqualified work of such kind may trigger fire or personal injury. Unplug the power plug when failure occurred, and lasting abnormal running of the appliance may result in electric shock or fire. The safe usage sites of the refrigerator is needed when the materials handled are poisonous, harmful or radioactive, and improper usage of it may pose unhealthy impacts on you and the environment. The wastes of the refrigerator need to be disposed by specialized personnel, no arbitrary movement of it is allowed; or otherwise, events of kids being shut in it may occur. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. For temperature abnormalities or alarming, if any, no matter whatever reason, articles in the refrigerator shall be transferred as soon as possible so as to avoid your losses. Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. CP/IP foaming materials are flammable, need professional processing. Do not attempt to use the handle to lift or move the unit to avoid damaging the freezer or injuring personnel. 08/15 162346 Rev A. Correct Operation right indicates carefulness. Unplug the power plug indicates prohibition. indicates provisions. Do not disassemble 7) Do not load excessive material in the appliance , which has been thoroughly tested and assured as operational. K eep ground wire connected Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. This operation manual should remain attached to this appliance. Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. Do not damage the refrigerant circuit. This warning is only applicable for appliances with refrigerating circuits which are accessible by the user. Do not use electrical appliances inside the food storage compartments of the appliance unless they are of the type recommended by the manufacturer. The appliance must be positioned so that the plug is accessible. The appliance must be placed on a solid and flat surface, or excessive vibration and noise may be produced when the appliance in operation. If your cabinet is to be discard,you must remove the door and leave the shelves in place. This will reduce the possibility of danger to children. And the flammable foaming needs to be diposed by professional persons. 08/15 162346 Rev A. NorLake Lighting Lamp Replacement Please contact professional personnel at the after-sales center for replacement in case of LED lamp failure. Meaning of crossed-out wheeled dustbin: Don't dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and wellbeing. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge. 08/15 162346 Rev A. LR051WWW/0 LR051WWG /0 118L LR031WWW/0 LR031WWG/0 68L Solid door Names of components Shelves/Bins Cooling Type Solid door 1 2 Forced air cooling 3 1 1 101.4 lbs/46kg Exterior Dimensions W× D× H 90.4 lbs/41kg 597 ×645 ×835mm 23.5 ×25.4 ×32.9(in) Noise Electric Shock Prevention Type Foaming Cabinet 83.8 lbs/38kg 83.8 lbs/38kg 495 ×580 ×660mm 19.5 ×22.8 ×26.0(in) 30dB(A) CP/IP Climate Type The connecting method of power wire 4 Y NOTE: Climate Type 4 means the temperature is +30 LR051WWW/0 , the relative humidity is 55%. LR051WWG /0 LR031WWW/0 LR031WWG /0 Power Supply(V/Hz) 115~/60 115~/60 Electrical Current(A) 1.05 0.65 Power(W) 160 84 Accessories LR051WWW/0 LR051WWG /0 LR031WWW/0 LR031WWG /0 Please take care of the key,if lost ,please contact the seller. 08/15 162346 Rev A. NorLake Lighting Lamp Replacement Please contact professional personnel at the after-sales center for replacement in case of LED lamp failure. Meaning of crossed-out wheeled dustbin: Don't dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and wellbeing. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge. 08/15 162346 Rev A. Pharmaceutical Refrigerator Operation Manual LR051WWW/0 LR051WWG/0 LR031WWW/0 LR031WWG/0 Read the Operation Manual carefully before using your appliance. Keep the Operation Manual in a safe place. Appearance, color and layout of the door may vary. The Scope of the Product Application: Pharmaceuticals, medicine and other related products which need a storage environment of 2 -8 . 08/15 162346 Rev A.