GE Full-Voltage Manual Starters CR101H, CR101Y Manual Motor Starters Single-Phase 1 Horsepower Maximum at 115 or 230 Volts % Horsepower Maximum at 277 Volts for 2-Pole Forms 25 to 60 Hertz Single-Speed Open and NEMA Type 1 Forms Catalog Number Open® No. of Poles For Flush or Outlet Box Mtg. NEMA Type 1 List Price, GO-10G3® Surface Mounting List Price, GO-10G3® Surface Mounting Wind. Light® List Price, GO-10G3® Toggle-Operated 1 CR101Y® CR101H® 2 Key-Operated 1 2 CR101YOOOK CR101HOOOK $33.00 39.00 45.00 51.00 CR101Y1® CR101H1® $39.0I0 45.0 0 CR101Y100K CR101H100K CR101Y11 CR101H11 51.00 57.0 0 $57.00 63.00 CR101Y110K CR101H110K 69.00 75.00 Single-Speed NEMA Type 3/4/12 Forms No. of Poles List Price, GO-10G3® Catalog Number Lever-Operated — %-inch Hub on One End 1 CR101Y400H 2 $138.00 144.00 CR101H400H Lever-Operated —3A-inch Hub on Both Ends 1 CR101Y400J 150.00 156.00 CR101H400J 2 Factory Modification: Indicating light, Type 4 forms, add $210.00, GO-10G3 to list price. Two-Speed Surface and Flush-Mounted NEMA Type 1 Forms Indicating Lights (230V Max.) No. of Poles 1 1 None Two® None Two® 2 2 Catalog Number Surface Mounting List Price, GO-10G3® CR101Y600B CR101Y610B CR101H600B CR101H610B Gray Flush-Plate CR101Y600A CR101Y610A CR101H600A CR101H610A $172.00 255.00 187.00 270.00 List Price, GO-10G3® Stainless-Steel Flush-Plate List Price, GO-10G3® $165.00 247.00 180.00 262.00 CR101Y608A CR101Y618A CR101H608A CR101H618A $172.00 255.00 187.00 270.00 Combination Device, NEMA Type 1 For Surface Mounting Catalog Number List Price, GO-10G3® CR101H12 (CR101H + Hand-Auto Switch) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CR101H13(TwoCR101H)........ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $102.00 108.00 No. of Poles 2 2 © Open starters include an unmounted nameplate. ® List prices do not include heater(s). Heaters can be selected from table at right and ordered as a separate item at $6.00 each, GO-10H: One heater is required per starter (two for 2-speed forms and for combination starter, CR101H13). ® Includes a 115/230-Volt neon lamp(s). Not available at 277 Volts. ® Units are individually boxed and "Poly-Packed" 10 per carton as standard. Maximum Horsepower Ratings—AC or DC Continuous Carry—16 Amperes AC Voltage Starter Catalog Number No. of Poles CR101Y Single 1 CR101H Double 1 32 /4 /4 DC Voltage 115 230 277 115 1 1 - 1 1 1 Vt 1 230 1 /4 1 Overload Heater Units ForCR101H,Y All CR123H heaters are packaged as single units. Catalog Number List Price Each, GO-1 OH CR123H(all) $6.00 The table below gives a proper size heater to trip the switch on approximately 125 percent motor current. Listed values are for motors with 1.15-1.25 service factor. For motors with 1.0 service factor continuously, multiply full-load current of motor by 0.9 and use this value to select heater. Contact nearest GE Industrial Systems— Electrical Distribution and Control Representative for recommendation for heaters to be used with definite-purpose motors. If motor full-load Amperes falls between two ratings, select heater for the highest of those two. For 1.35 service factor motors, multiply full-load current of motor by 1.15 and use this value to select heater(s). Maximum Motor Full-Load Amperes .48 .53 .58 .65 .71 .78 .86 .95 1.04 1.14 1.25 1.37 1.49 1.63 1.78 1.95 2.13 2.32 2.53 2.76 3.01 3.27 3.56 3.88 4.22 4.60 5.00 5.43 5.90 6.41 6.98 7.60 8.25 8.95 9.75 10.6 11.4 12.5 13.6 14.8 16.0 Prices and data subject to change without notice 1999 Issue Heater Catalog Number CR123H055A CR123H061A CR123H067A CR123H074A CR123H082A CR123H090A CR123H099A CR123H108A CR123H120A CR123H132A CR123H144A CR123H158A CR123H172A CR123H188A CR123H205A CR123H224A CR123H245A CR123H267A CR123H291A CR123H317A CR123H346A CR123H377A CR123H410A CR123H446A CR123H486A CR123H529A CR123H575A CR123H625A CR123H680A CR123H739A CR123H802A CR123H873A CR123H950A CR123H103B CR123H112B CR123H122B CR123H132B CR123H144B CR123H157B CR123H171B CR123H186B 7-3 GE Full-Voltage Manual Starters CH101H, CHW1Y Manual Motor Starters Single-Phase 1 Horsepower Maximum at 115 or 230 Volts 3 /4 Horsepower Maximum at 277 Volts for 2-Pole Forms 25 to 60 Hertz Open Starter Manual Starter in NEMA Type 1 GeneralPurpose Enclosure Manual Starter With Indicating Light NEMA Type 4 Water- and Dust-Tight Manual Starter Two-Speed Surface-Mounted Manual Starter HAND Combination General-Purpose Manual Starter Application Ordering Directions Designed for starting and stopping single-phase fractional horsepower motors. These manual starters have provision for overload protection and their low cost provides economical starter selection for applications where no undervoltage protection is required. This line of starters may be used on such equipment as grinders, conveyors, fans, mixers, and blowers. Order starter by complete Catalog Number and specify overload heater as a separate item by complete Catalog Number. Features • Terminal design—box terminals provide easy access for wiring. • Molded plastic switch housing—protects starter mechanism. • Small size—open starter fits GEM or handy box. Heater Selection Tables........ 7-2 I . page 7-3 Examples: 1. A general-purpose enclosed starter for surface wall mounting is desired. The starter is to break both lines. Motor to be started with this device has a full-load current of 0.6 Ampere. Order 1 CR101H1 manual motor starter at $45.00 each, GO-10G3. 1 CR123H074A heater at $6.00 each, GO-10G3. 2. The complete combination surface-mounted station, CR101H12, may also be ordered by components, e.g. order 1—CR101X10 flush plate, at $71.00 each, GO-10G3; 1— CR101X14 box at $6.00 each, GO-10G3; and 1—CR101H manual starter at $39.00 each, GO-10G3. The other complete general-purpose manual starters may be broken down in this manner. 1999 Issue Prices and data subject to change without notice