HID Catalog - McWong Inc.

advertisement
HID Catalog
About us
For over 25 years, McWong International, Inc. has been bridging the best of East and West in order to achieve for our valued customers an
unparalleled mix of innovation, quality, and service. A California corporation, McWong has grown to become a leader in the design and
manufacture of high quality lighting control equipment and related electrical components. Our teams on both sides of the Pacific take
great pride in the fact that the majority of our growth comes from organic nurturing of business with long-term, world-class customers.
Reliable, competitive products paired with committed customer service year in and year out have enabled sustained growth over more
than two decades.
Today, the pace of technological change has quickened and competition continues to intensify. We are meeting these challenges through
heightened investment in capable individuals, promising technologies and advanced manufacturing facilities. McWong’s disciplined
approach to quality management, customer service, and cost control ensures that we are well-poised to accelerate our pace of growth as
we partner with our stakeholders to achieve a brighter, more sustainable, more successful future.
Pacific Ballast® HID
For more than a decade, major US customers have come to rely on McWong’s Pacific Ballast HID. In an unrelenting process of ongoing
improvement, we strive to ensure delivery of our core values in every product .
Innovation:
One of the coolest, quietest lines in the industry
Broad product offering – over 350 UL recognized models and growing
UL 200˚C Insulation System standard production for all core & coil units
EISA compliant offering one of the broadest in the market
Enhanced ANSI waveform compliance testing
Quality:
ISO9001 certified production facilities
Automated In-line Testing with individually trackable date codes on 100% of our ballasts
Quality construction, precision coil windings
Automated Vacuum Pressure Impregnation
Automated Arc Welding ensures tight, noise-free cores
Service:
Custom design capabilities
Expanded warehousing to support North American customers
Unsurpassed after sales service and support
New / Unique Offerings:
·
·
·
·
·
F-Can line — 50, 70, 100, 150W — watch for more models coming soon.
Magnetic Regulated Lag “Mag Reg” — HPS 70, 100, 150, 200, 310, 250, 400W and MP 175, 400W
Bi-level Dimming Compatible line
New offering of Ultra-high efficiency ballasts. (Efficiencies >90%) — Linear Reactors and special designed Pulse-CWA units.
Auto-shutoff Ignitors now available; Long-Range Ignitors coming soon...
This catalog offers just a partial list of our common items. Contact McWong for additional SKUs.
HID
Contents
Pacific Ballast Model Number Information ……………………02
Warranty ………………………………………………………03
Metal Halide Ballasts (Pulse and Standard) ……………………04
High Pressure Sodium Ballasts…………………………………18
Ignitors (Starters) ………………………………………………28
F.CAN HID Ballasts………………………………………………30
Stepdown Autotransformers …………………………………32
Specifications subject to change without notice.
Page 01
Pacific Ballast® HID Model Numbers
4
2
5
1
1
3
F
MP
MH
MH
HPS
MP
HPS
M or P or S
Ⅰ
Ⅱ
400
70
250
1000
175
310
50
Ⅲ
R
MR
HX
SAA
SC
SCA
SCA
SC
SC
SAA
48
277
63
92
Ⅳ
Ⅴ
Ⅵ
HX
Coil :
Precision
wound,
Al/Al
Cu/Al
Cu/Cu
Cu/Cu/Cu
Input Volt Tap Code:
12 (120)
27 (277)
48 (480)
52 (120, 347)
53 (240, 277, 347)
62 (347, 480)
63 (240, 277, 480)
72 (240, 480)
73 (277, 347, 480)
74 (240, 277, 347, 480)
82 (120, 240)
83 (120, 240, 277)
84 (120, 240, 277, 480)
92 (120, 277)
Blank = default, see
position ‘A’ notes.
/T
-PS
T
-TAB
Ⅶ
Suffix Codes:
/T (T) = 120T;
-TAB = fast-on
quick connect tabs in
leiu of lead wires;
-PS = MH pulse start,
non-EISA compliant.
Reference add’l
ordering suffices in the
footnotes of each spec
sheet and/or catalog
listing.
Circuit Type:
Blank (default) = CWA
HX = High Reactance
MR = MagReg
R = Linear Reactor
Lamp Watts (Nominal): 35 – 2000W
F=F.CAN or Number of Input Taps: 1, 2, 3, 4, 5, 6;
if no voltage tap suffix code appears in position ‘F’,
then default applies:
‘5’ = 120/208/240/277/480
‘4’ = 120/208/240/277
‘2’ = Dual 480V/120T.
Page 02
Lamp Type:
HPS = High Pressure Sodium (F.CAN=FS)
MH (absent of ‘-PS’ suffix) =
Standard Metal Halide (probe/switch start); (F.CAN=FM)
MH (followed by ‘-PS’ suffix) =
non-EISA Pulse Start Metal Halide; (F.CAN=FP)
MP = EISA Pulse Start Metal Halide
HID
PACIFIC BALLAST® LIMITED WARRANTY
McWong International, Inc. ("MCWONG"), 2544 Industrial Blvd., West Sacramento, California 95691, warrants its lamp ballasts to be free
from defect in material and workmanship from the date of manufacture by MCWONG for the following time periods:
High Intensity Discharge (HID)................................................ 2 Years
Electromagnetic Fluorescent (Residential)......................... 2 Years
Electromagnetic Fluorescent (Commercial)....................... 3 Years
Electronic Fluorescent (Residential)...................................... 2 Years
Electronic Fluorescent (Commercial).................................... 5 Years
Date codes for electromagnetic ballast(s) are stamped in the underside of the ballast can.
Date codes for electronic ballast(s) can be found on the label and/or stamped into the underside of the can.
Date codes for HID Ballast(s) can be found imprinted on the end of the lamination and/or on date code label applied to coils.
Pacific Ballast® labels show our toll free number – 888-600-9188 allowing convenient contact directly with a qualified technical
support administrator. Warranty claims may also be submitted online by visiting www.mcwonginc.com
and clicking on Technical Support / Warranty.
This warranty is not applicable to any ballast subjected to abnormal stresses. Validity of this warranty is also conditioned upon proper
storage, installation, use and maintenance. This warranty is not applicable to any PACIFIC BALLAST® product not installed and
operated in accordance with:
The National Electrical Code (NEC)
The standards for safety of Underwriter's Laboratories, Inc. (UL)
The standards of the American National Standards Institute (ANSI)
Relevant electrical ratings and Maximum Temperature Ratings
The specific instructions provided by MCWONG for the installation of the product(s)
If it appears that the product does not meet the warranty specified above, the Purchaser must notify MCWONG of its claim in writing
at the address above and, after receiving proper authorization, must promptly return the product(s) at purchaser's expense to
MCWONG – unless prior arrangement has been made with MCWONG for other RGA dispositioning. MCWONG shall correct any
defects, at MCWONG's option, by either repairing any defective part(s), by making available a replacement ballast, or by extending a
credit in the amount of the ballast purchase price.
The standards and conditions of any tests concerning any PACIFIC BALLAST® claimed to have not performed to this warranty shall be
mutually agreed upon in writing and MCWONG shall be notified of, and may be represented at any such tests. This express limited
warranty is extended by MCWONG only to the original or first end-user purchaser.
NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND THE
AFOREMENTIONED BALLAST WARRANTY PERIOD. This warranty is exclusive of all other statutory, written or oral warranties and no
other warranties of any kind, statutory or otherwise, are given or herein expressed.
Under no circumstances, whether as a result if breach of contract, breach of warranty, tort, strict liability or otherwise, will MCWONG be
liable for consequential, incidental, special or exemplary damages, including, but not limited to, loss of profits, loss of use or damage to
any property or equipment, cost of capital, cost of substitute products, facilities or services, downtime costs or claims of any kind or
any loss or damage arising out of, resulting from, or concerning any aspect of this agreement of from the products or services
furnished.
Page 03
METAL HALIDE
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
(A)
Ballast
Dimensions
A(in) B(in)
Fig
Net
WT Wiring
(lbs) Diagram
Pacific
Ignitor/
Starter
1029
Class
Capacitor
EISA
(µF)
VAC
min
H
180
N
200
50 Watt Lamp, ANSI Code M110, M148
120/208
240/277
4MH50HXSAA
HX-HPF
70
4
1.2/0.8
0.6/0.5
1.0
2.5
1
3.1
A
MHR1
6
280
AA
AA
AA
AA
70 Watt Lamp, ANSI Code M98, M143
120/208
240/277
4MH70HXSCA
HX-HPF
85
4
1.6/0.9
0.8/0.7
1.5
2.9
1
4.5
A
MHR1
8
280
AA
AA
AA
AA
480
2MH70HXSC/T
HX-HPF
88
2
0.5
1.5
2.8
1
5.0
B
MHR1
8
280
C
A
120T
100 Watt Lamp, ANSI Code M90, M140
120/208
240/277
4MH100HXSCA
HX-HPF
120
4
2.4/1.4
1.2/1.1
1.6
3.0
1
4.8
A
MHR1
12
280
BA
AA
AA
AA
480
2MH100HXSC/T
HX-HPF
120
2
0.6
1.6
2.8
1
5.0
C
MHR1
12
280
C
A
120T
150 Watt Lamp, ANSI Code M102, M142
120/208
240/277
4MH150HXSCA
HX-HPF
182
4
3.4/2.0
1.7/1.5
2.3
3.8
1
6.8
A
MHR1
16
280
BB
AA
AA
AA
EX
480
2MH150HXSC/T
HX-HPF
185
2
0.9
2.3
3.9
1
7.0
D
MHR1
16
280
E
A
EX
4MP150SCA
PS-CWA
186
4
1.6/1.0
0.8/0.7
2.4
3.9
1
6.9
E
HPS24
16
330
CC
CB
AA
AA
EX
120T
120/208
240/277
EX: Meets EISA under exception for >50°C ambient temperature for wet/damp location fixture
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.)
Contact McWong for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig 1
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 1
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 04 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
BALLAST DIMENSIONS
Fig. 1
Fig. 2
"B"
5.750
"A"
4.375
4.250
5.375
3.875
0.195 Min. (8X)
Fig. 3
B max.
Fig. 4
4.50
A
3.30
3.75
∅0.175Min.(4X)
4.05
Fig. 5
Fig. 6
"B"
2 5/8"
B max. A
4.750
"A"
4.250
1 25/32"
4 Holes >= 0.175"
Cleared for #6 bolts
2 7/32" x 2 5/8" core
2 7/32"
4.375
3.875
2 3/16"
Fig. 7
Fig. 8
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 05
METAL HALIDE
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
(A)
Ballast
Dimensions
A(in) B(in)
Fig
Net
WT Wiring
(lbs) Diagram
Pacific
Ignitor/
Starter
1029
Class
Capacitor
EISA
(µF)
VAC
min
H
180
N
200
175 Watt Lamp, ANSI Code M57; or 150 Watt Lamp, ANSI Code M107
120/208
240/277 4MH175SCA
CWA
207
4
1.9/1.1
1.0/0.8
2.4
3.8
1
6.8
F
n/a
10
400
BC
CC
AA
AA
120
277/347 3MH/MV175SCC
CWA
207
3
1.7
0.9/0.8
2.4
4.0
1
7.8
G
n/a
10
400
B
CC
A
AA
120/208
240/277 5MH175SCA
480
CWA
210
5
1.9/1.1
0.9/0.8
0.5
2.4
4.1
1
6.9
H
n/a
10
400
CB
BB
A
AA
AA
A
175 Watt Lamp, ANSI Code M137, M152 (Pulse Start)
120/208
240/277 4MH175SAA-PS
PS-CWA
202
4
1.8/1.0
0.9/0.8
2.6
4.0
1
6.9
E
MHR3
10
400
CC
BB
AA
AA
120/208
240/277 4MP175SCA4
PS-CWA
203
4
1.8/1.0
0.9/0.8
1.9
3.9
4
10.0
E
MHR3
13
330
BB
BB
AA
AA
Y
120/208
240/277 4MP175SC
PS-CWA
196
4
1.8/1.0
0.9/0.7
3.1
4.3
2
10.1
E
MHR3
13
350
AA
AA
AA
AA
Y
120/208
240/277 5MH175SC-PS
480
PS-CWA
210
5
2.0/1.2
1.1/0.9
0.6
2.4
3.5
1
7.8
I
MHR3
10
400
BB
BB
C
AA
AA
A
PS-CWA
201
1
0.4
3.2
4.5
1
9.5
U
MHR3
11
400
C
A
1.7
3.4
3
12.6
J
MHR1
17
330
A
AA
A
AA
480
1MP175SC48
REG LAG
215
3
1.9
1.0/0.8
240/277
347/480 4MP175MRSC74* REG LAG
215
4
1.0/0.8
0.7/0.5
1.7
3.4
3
12.6
K
MHR1
17
330
AA
AA
AA
AA
120
240/277 3MP175MRSC83
Y
200 Watt Lamp, ANSI Code M136 (Pulse Start)
120/208
240/277 4MP200SC3
PS-CWA
215
4
2.1/1.2
1.1/0.9
3.0
4.4
1
9.3
E
MHR3
13
330
AA
AA
AA
AA
Y
120/208
240/277 4MP200SCA
PS-CWA
235
4
1.8/1.1
0.9/0.8
2.0
3.7
4
10.2
E
MHR3
16
300
AA
AA
AA
AA
Y
* Add "T" to denote 120V aux. tap option for standby lighting
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as
necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig 1, 2
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 1, 2
For Ballast Dimensions Fig. 3, 4
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
For Ballast Dimensions Fig 3
For Ballast Dimensions Fig 4
Page 06 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
WIRING DIAGRAMS
Fig. A
480V (vio/wht)
LAMP (Red)
CAP (blk/wht)
X3 (Blue)
LAMP (red)
277V (black)
X1
(Red)
X3
(blue)
240V (violet)
120V Aux
(blk/yel)
IGNITOR
208V (orange)
CAP
(blk/wht)
120V (blk/yel)
Max 150W
Incandescent
Lamp
COM (white)
CAP
240V (violet)
208V (orange)
120V (blk/yel)
X2
(white)
CAP
COM (White)
COM (White)
CAP
(blk/wht)
277V (black)
LAMP
X2
(White)
X1
(red)
LAMP
CAP
LAMP
IGNITOR
COM
(White)
Fig. C
Fig. B
COM (white)
COM (white)
COM (white)
Fig. D
Fig. F
Fig. E
LAMP (red)
480V(vio/wht)
(blk/wht)
277V (black)
CAP
LAMP
277V (black)
240V (violet)
COM (white)
120V (blk/yel)
COM (white)
COM (white)
Fig. I
Fig. H
480V (violet/wht)
X1
(red)
IGN
X3 (blue)
LAMP1
347V (org/wht)
X1
(red)
IGN
X3 (blue)
277V (black)
X2
(white)
LAMP2 (red/wht)
480V (vio/wht)
X3
(blue)
X1
(red)
IGNITOR
120V Aux
(blk/yel)
LAMP2 (red/wht)
240V (violet)
CAP
(blk/wht)
CAP (blk/wht)
CAP (blk/wht)
Max 250W
Incandescent
Lamp
CAP
CAP
COM (white)
COM (white)
LAMP (red)
X2
(white)
X2
(white)
CAP
COM (white)
CAP (blk/wht)
CAP (blk/wht)
Fig. J
COM (white)
Fig. L
Fig. K
LAMP (red)
480V (vio/wht)
347V (org/wht)
LAMP (red)
277V(black)
LAMP (red)
X3 (blue)
CAP
X1 (red)
IGNITO
R
IGNITOR
208V (orange)
CAP
CAP
(blk/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
COM (white)
Fig. O
Fig. N
480V (Vio/wht)
480V (vio/wht)
277V (black)
CA P
240V (violet)
CA P
120V (blk/yel)
208V (orange)
CAP
Fig. P
277V (black)
X3 (blue)
Fig. S
LAMP (red)
480V(vio/wht)
X3
(blue)
IGNITOR
LAMP2 (red/wht)
CAP (blk/wht)
CAP
(blk/wht)
CAP
COM (white)
CAP (blk/wht)
Fig. T
X1
(red)
CAP
COM (white)
COM (white)
Fig. U
CAP
(blk/wht)
CAP
LAMP
COM (white)
120V (blk/yel)
X1
(red)
IGN
LAMP
X2
(white)
LAMP
COM (white)
X1 (red)
IGNITO
R
Fig. R
X2
(white)
LAMP (red)
X3 (blue)
COM (White)
COM (White)
LAMP1
240V (violet)
CAP
(Optional)
Max 400W
Incandescent
Lamp
CAP
Fig. Q
480V (violet/wht)
120V(blk/yel)
CAP
(Blk/wht)
COM (white)
COM (white)
COM (white)
120V Aux (blk/yel)
CAP
120V (blk/yel)
COM (white)
LAMP
208V (orange)
240V (violet)
CAP
LAMP (red)
LAMP
277V (black)
CAP
(blk/wht )
CAP
LAMP
347V (org/wht)
CAP
(blk/wht)
X2
(White)
CAP
COM (white)
COM (white)
Fig. M
X1
(red)
240V (violet)
X2
(white)
CAP
(blk/wht)
X3
(blue)
277V (black)
LAMP
LAMP
IGNITOR
COM (white)
347V (org/wht)
X1
(red)
LAMP
X3
(blue)
277V (black)
120V (blk/yel)
LAMP
240V (violet)
X2
(white)
CAP
COM (white)
COM (white)
COM (white)
LAMP1
120V (blk/yel)
CAP
(blk/wht)
120V (blk/yel)
Fig. G
277V (black)
IGNITOR
208V (orange)
208V (orange)
120V (blk/yel)
X1
(red)
240V (violet)
LAMP
CAP
(blk/wht)
CAP
LAMP
347V (org/wht)
X3
(blue)
277V (black)
CAP
480V (vio/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
Fig. V
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 07
METAL HALIDE
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
Max
Ballast
Input
Dimensions
# of Current
Taps
(A)
A(in) B(in) Fig
Net
WT Wiring
(lbs) Diagram
Pacific
Ignitor/
Starter
Capacitor
1029
Class
EISA
(µF)
VAC
min
H
180
N
200
250 Watt Lamp, ANSI Code M58
120/208
240/277
4MH250SAA
CWA
295
4
2.6/1.5
1.3/1.2
1.6
3.5
4
8.0
F
n/a
15
400
AA
AA
AA
AA
120/208
240/277
4MH250SAA3
CWA
294
4
2.8/1.6
1.4/1.2
3.2
4.5
1
8.4
F
n/a
15
400
EE
EE
AA
AA
120/208
240/277
480
5MH/MV250SC-3
CWA
291
5
3.2/1.9
1.6/1.4
0.8
3.0
4.4
1
9.0
H
n/a
15
400
CC
BB
A
AA
AA
A
120/208
240/277
480
5MH250SCA
CWA
289
5
2.9/1.7
1.6/1.2
0.8
1.8
3.6
4
10.2
H
n/a
15
400
AA
AA
A
AA
AA
A
250 Watt Lamp, ANSI Code M153, M138 (Pulse Start)
120/208
240/277
4MH250SAA-PS
PS-CWA
278
4
2.5/1.4
1.3/1.1
1.9
3.8
4
9.8
E
MHR3
15
400
AA
AA
AA
AA
120/208
240/277
4MP250SAA
PS-CWA
290
4
2.5/1.5
1.3/1.1
2.2
4.2
4
10.6
E
MHR3
17
400
BB
BA
AA
AA
Y
120/208
240/277
4MP250SCA
PS-CWA
288
4
2.7/1.6
1.4/1.2
2.2
3.9
4
11.0
E
MHR3
15
400
AA
AA
AA
AA
Y
120/208
240/277
4MP250SCE
PS-CWA
278
4
2.3/1.4
1.2/1.0
2.2
4.3
4
13.8
E
MHR3
17
400
AA
AA
AA
AA
YY
120/208
240/277
480
5MH250SCA-PS
PS-CWA
282
5
2.5/1.4
1.3/1.1
0.65
2.0
3.9
4
11.5
I
MHR3
15
400
AA
AA
A
AA
AA
A
120/208
240/277
480
5MP250SCA
PS-CWA
288
5
2.7/1.6
1.3/1.2
0.7
2.2
4.4
4
11.5
I
MHR3
15
400
AA
AA
A
AA
AA
A
Y
YY: Exceeds EISA efficiency >90%
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as
necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig 1
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 1
For Ballast Dimensions Fig 4
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
For Ballast Dimensions Fig 4
Page 08 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
BALLAST DIMENSIONS
Fig. 1
Fig. 2
"B"
5.750
"A"
4.375
4.250
5.375
3.875
0.195 Min. (8X)
Fig. 3
B max.
Fig. 4
4.50
A
3.30
3.75
∅0.175Min.(4X)
4.05
Fig. 5
Fig. 6
"B"
2 5/8"
B max. A
4.750
"A"
4.250
1 25/32"
4 Holes >= 0.175"
Cleared for #6 bolts
2 7/32" x 2 5/8" core
2 7/32"
4.375
3.875
2 3/16"
Fig. 7
Fig. 8
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 09
METAL HALIDE
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
(A)
Ballast
Dimensions
A(in) B(in)
Fig
Net
WT Wiring
(lbs) Diagram
Pacific
Ignitor/
Starter
1029
Class
Capacitor
EISA
(µF)
VAC
min
H
180
N
200
320 Watt Lamp, ANSI Code M132, M154, M170 (Pulse Start)
480
PS-CWA
359
2
0.8
2.2
4.2
4
11.5
L
MHR3
21
345
C
120/208 4MP320SAA
240/277
PS-CWA
361
4
3.1/1.8
1.6/1.35
2.2
4.4
4
11.0
E
MHR3
21
345
BB
BB
AA
AA
Y
120
3MP320SCC
277/347
PS-CWA
362
3
3/1.3
1.1
2.0
3.8
4
12.0
M
MHR3
21
345
BB
A
A
AA
Y
366
5
2.2
4.3
4
11.5
I
MHR3
21
345
338
1
1.3
3.0
5
5.7
N
MHR3
21
345
CC
CC
C
B
AA
AA
A
A
YY
120T
2MP320SCA/T
120/208
240/277 5MP320SCA
PS-CWA
480
1MP320RSCA277 R-HPF
277
3.1/1.8
1.6/1.4
0.8
2.3
Y
Y
350 Watt Lamp, ANSI Code M131 (Pulse Start)
120/208 4MP350SAA
240/277
PS-CWA
390
4
3.3/1.9
1.6/1.4
2.3
4.4
4
11.4
E
MHR3
24
400
BB
BA
AA
AA
Y
120/208 4MP350SCA
240/277
PS-CWA
400
4
3.3/2.0
1.8/1.5
2.3
4.4
4
11.8
E
MHR3
24
400
AA
AA
AA
AA
Y
120/208
240/277 5MP350SCA
480
PS-CWA
410
5
3.4/2.0
1.7/1.5
0.9
2.3
4.4
4
12.2
I
MHR3
24
330
AA
AA
A
AA
AA
A
Y
120/208
240/277 6MP350SCA
347/480
PS-CWA
410
6
3.4/2.0
1.7/1.5
1.3/0.9
2.3
4.4
4
12.2
O
MHR3
24
330
AA
AA
AA
AA
AA
AA
Y
YY: Exceeds EISA efficiency >90%
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as
necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig 4
For Ballast Dimensions Fig 5
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 4
For Ballast Dimensions Fig 5
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 10 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
WIRING DIAGRAMS
Fig. A
480V (vio/wht)
LAMP (Red)
CAP (blk/wht)
X3 (Blue)
LAMP (red)
277V (black)
X1
(Red)
X3
(blue)
240V (violet)
120V Aux
(blk/yel)
IGNITOR
208V (orange)
CAP
(blk/wht)
120V (blk/yel)
Max 150W
Incandescent
Lamp
COM (white)
CAP
240V (violet)
208V (orange)
120V (blk/yel)
X2
(white)
CAP
COM (White)
COM (White)
CAP
(blk/wht)
277V (black)
LAMP
X2
(White)
X1
(red)
LAMP
CAP
LAMP
IGNITOR
COM
(White)
Fig. C
Fig. B
COM (white)
COM (white)
COM (white)
Fig. D
Fig. F
Fig. E
LAMP (red)
480V(vio/wht)
(blk/wht)
277V (black)
CAP
LAMP
277V (black)
240V (violet)
COM (white)
120V (blk/yel)
COM (white)
COM (white)
Fig. I
Fig. H
480V (violet/wht)
X1
(red)
IGN
X3 (blue)
LAMP1
347V (org/wht)
X1
(red)
IGN
X3 (blue)
277V (black)
X2
(white)
LAMP2 (red/wht)
480V (vio/wht)
X3
(blue)
X1
(red)
IGNITOR
120V Aux
(blk/yel)
LAMP2 (red/wht)
240V (violet)
CAP
(blk/wht)
CAP (blk/wht)
CAP (blk/wht)
Max 250W
Incandescent
Lamp
CAP
CAP
COM (white)
COM (white)
LAMP (red)
X2
(white)
X2
(white)
CAP
COM (white)
CAP (blk/wht)
CAP (blk/wht)
Fig. J
COM (white)
Fig. L
Fig. K
LAMP (red)
480V (vio/wht)
347V (org/wht)
LAMP (red)
277V(black)
LAMP (red)
X3 (blue)
CAP
X1 (red)
IGNITO
R
IGNITOR
208V (orange)
CAP
CAP
(blk/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
COM (white)
Fig. O
Fig. N
480V (Vio/wht)
480V (vio/wht)
277V (black)
CA P
240V (violet)
CA P
120V (blk/yel)
208V (orange)
CAP
Fig. P
277V (black)
X3 (blue)
Fig. S
LAMP (red)
480V(vio/wht)
X3
(blue)
IGNITOR
LAMP2 (red/wht)
CAP (blk/wht)
CAP
(blk/wht)
CAP
COM (white)
CAP (blk/wht)
Fig. T
X1
(red)
CAP
COM (white)
COM (white)
Fig. U
CAP
(blk/wht)
CAP
LAMP
COM (white)
120V (blk/yel)
X1
(red)
IGN
LAMP
X2
(white)
LAMP
COM (white)
X1 (red)
IGNITO
R
Fig. R
X2
(white)
LAMP (red)
X3 (blue)
COM (White)
COM (White)
LAMP1
240V (violet)
CAP
(Optional)
Max 400W
Incandescent
Lamp
CAP
Fig. Q
480V (violet/wht)
120V(blk/yel)
CAP
(Blk/wht)
COM (white)
COM (white)
COM (white)
120V Aux (blk/yel)
CAP
120V (blk/yel)
COM (white)
LAMP
208V (orange)
240V (violet)
CAP
LAMP (red)
LAMP
277V (black)
CAP
(blk/wht )
CAP
LAMP
347V (org/wht)
CAP
(blk/wht)
X2
(White)
CAP
COM (white)
COM (white)
Fig. M
X1
(red)
240V (violet)
X2
(white)
CAP
(blk/wht)
X3
(blue)
277V (black)
LAMP
LAMP
IGNITOR
COM (white)
347V (org/wht)
X1
(red)
LAMP
X3
(blue)
277V (black)
120V (blk/yel)
LAMP
240V (violet)
X2
(white)
CAP
COM (white)
COM (white)
COM (white)
LAMP1
120V (blk/yel)
CAP
(blk/wht)
120V (blk/yel)
Fig. G
277V (black)
IGNITOR
208V (orange)
208V (orange)
120V (blk/yel)
X1
(red)
240V (violet)
LAMP
CAP
(blk/wht)
CAP
LAMP
347V (org/wht)
X3
(blue)
277V (black)
CAP
480V (vio/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
Fig. V
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 11
METAL HALIDE
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
Max
Ballast
Input
Dimensions
# of Current
Taps
(A)
A(in) B(in) Fig
Net
WT Wiring
(lbs) Diagram
Pacific
Ignitor/
Starter
Capacitor
1029
Class
EISA
(µF)
VAC
min
H
180
N
200
400 Watt Lamp, ANSI Code M59
120/208 4MH400SAA
240/277
CWA
458
4
4.0/2.3
2.0/1.8
2.2
4.2
4
11.0
F
n/a
24
360
BC
CD
AA
AA
120
277/347 3MH400SCA
CWA
457
3
4.0
1.8/1.4
2.3
4.2
4
12.8
G
n/a
24
360
B
CC
A
AA
120/208
240/277 5MH400SCA
480
CWA
452
5
4.0/2.3
2.0/1.81
2.3
4.3
4
11.4
H
n/a
24
360
BB
CC
C
AA
AA
A
120/208
240/277 6MH400SCA
347/480
CWA
435
6
4.5/2.6
2.2/1.9
1.6/1.1
2.3
4.4
4
12.5
P
n/a
24
400
BB
CC
CC
AA
AA
AA
400 Watt Lamp, ANSI Code M135, M155 (Pulse Start)
120/208 4MP400SAA
240/277
PS-CWA
460
4
4.0/2.3
2.0/1.8
2.4
4.2
4
11.2
E
MHR3
26
400
BC
DD
AA
AA
Y
120
277/347 3MP400SCA
PS-CWA
454
3
4.0
1.8/1.4
2.3
4.3
4
12.3
M
MHR3
26
400
A
CC
A
AA
Y
120/208
240/277 5MP400SCA
480
PS-CWA
458
5
3.8/2.2
1.9/1.7
0.9
2.3
4.3
4
12.2
I
MHR3
26
400
BB
BA
C
AA
AA
A
Y
120/240 3MP400MRSC83 REG LAG
277
240/277
347/480 4MP400MRSC74* REG LAG
468
3
3.7
5.6
3
23.8
J
MHR3
20
440
466
4
3.9/2.0
1.7
1.2/1.7
1.4/1
3.7
5.6
3
23.8
K
MHR3
20
440
AA
A
AA
AA
AA
A
AA
AA
4.4/2.6
2.2/1.9
2.3
4.4
4
11.4
E
MHR3
28
440
BB
BA
AA
AA
450 Watt Lamp, ANSI CODE M144 (Pulse Start)
120/208 4MP450SAA
240/277
PS-CWA
520
4
Y
* Add "T" to denote 120V aux. tap option for standby lighting
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as
necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig 3, 4
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 3
For Ballast Dimensions Fig 4
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 12 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
BALLAST DIMENSIONS
Fig. 1
Fig. 2
"B"
5.750
"A"
4.375
4.250
5.375
3.875
0.195 Min. (8X)
Fig. 3
B max.
Fig. 4
4.50
A
3.30
3.75
∅0.175Min.(4X)
4.05
Fig. 5
Fig. 6
"B"
2 5/8"
B max. A
4.750
"A"
4.250
1 25/32"
4 Holes >= 0.175"
Cleared for #6 bolts
2 7/32" x 2 5/8" core
2 7/32"
4.375
3.875
2 3/16"
Fig. 7
Fig. 8
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 13
METAL HALIDE
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
(A)
Ballast
Dimensions
A(in) B(in)
Fig
Net
WT Wiring
(lbs) Diagram
Pacific
Ignitor/
Starter
1029
Class
Capacitor
EISA
(µF)
VAC
min
H
180
N
200
750 Watt Lamp, ANSI Code M149; or 775 Watt Lamp, ANSI Code M181 (Pulse Start)
120/208 4MP750SCA
240/277
PS-CWA
842
4
7.2/4.1
3.6/3.1
2.6
4.8
6
17.0
E
MHR2
24
480
CB
CC
AA
AA
120
277/347 3MP750SCA03
PS-CWA
810
3
7.2
3.1/2.5
2.8
4.8
6
18.8
M
MHR2
24
480
B
AA
A
AA
120/208
240/277 5MP750SCA
480
PS-CWA
810
5
7.2/4.1
3.6/3.1
1.8
2.8
4.8
6
18.8
I
MHR2
24
480
BB
AA
A
AA
AA
A
120/208
240/277 6MP750SCA
347/480
PS-CWA
810
6
7.2/4.1
3.6/3.1
2.5/1.8
2.8
4.8
6
18.8
O
MHR2
24
480
BB
AA
AA
AA
AA
AA
875 Watt Lamp, ANSI CODE M166 (Pulse Start)*
*See 1000 Watt Lamp
1000 Watt Lamp, ANSI Code M47
120
1MH1000SAA-12
CWA
1070
1
90
3.0
5.0
6
18.7
V
n/a
24
480
D
A
120/208 4MH1000SCA
240/277
CWA
1076
4
9.2/5.3
4.6/4.0
3.0
4.9
6
18.9
F
n/a
24
480
DC
CC
AA
AA
120
277/347 3MH1000SCA03
CWA
1070
3
8.9/4.0
3.1
3.3
5.4
6
21.6
G
n/a
24
480
DB
C
AA
A
120/208
240/277 5MH1000SCA
480
CWA
1087
5
9.2/5.3
4.6/4.0
2.3
3.3
5.2
6
19.9
H
n/a
24
480
DC
CB
C
AA
AA
A
120/208
240/277 6MH1000SCA
347/480
CWA
1070
6
8.9/5.3
4.5/4.0
3.1/2.3
3.3
5.4
6
21.6
P
n/a
24
480
DC
CB
CC
AA
AA
AA
1000 Watt Lamp, ANSI Code M141, M47; or 875* Watt Lamp, ANSI Code M166 (Pulse Start)
120/208 4MP1000SCA
240/277
PS-CWA
1090
4
9.2/5.3
4.6/4.0
3.0
5.1
6
20.1
E
HPS1K
24*
480
CB
BB
AA
AA
120
3MP1000SCA03
277/347
PS-CWA
1075
3
8.9/4.0
3.1
3.3
5.4
6
22.0
M
HPS1K
24*
480
CA
B
AA
A
120/208
240/277 5MP1000SCA
480
PS-CWA
1070
5
8.8/5.1
4.5/3.9
2.3
3.3
5.2
6
21.4
I
HPS1K
24*
480
CB
BA
B
AA
AA
A
120/208
240/277 6MP1000SCA
347/480
PS-CWA
1075
6
8.9/5.3
4.5/4.0
3.1/2.3
3.3
5.4
6
22.0
O
HPS1K
24*
480
CB
BA
BB
AA
AA
AA
10.4/5.9
5.2/5.0
4.1
6.1
6
29.5
Q
◆
165
280
II
JJ
EE
FF
1000 Watt Lamp, ANSI Code CSI1000/PAR64/G38
120/208 4MH1000CSI
240/277
CWACSI
1140
4
* 875 Watt Lamp requires 22µ F, 480V capacitor
◆ Customer Supplied Ignitor
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as
necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
Welded Foot Bracket Dimensions:
Note: Bracket Dimensions in millimeters,
where 1milimeter = 1/25.4 inch
For Ballast Dimensions Fig 6
For Ballast Dimensions Fig 6
Page 14 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
WIRING DIAGRAMS
Fig. A
480V (vio/wht)
LAMP (Red)
CAP (blk/wht)
X3 (Blue)
LAMP (red)
277V (black)
X1
(Red)
X3
(blue)
240V (violet)
120V Aux
(blk/yel)
IGNITOR
208V (orange)
CAP
(blk/wht)
120V (blk/yel)
Max 150W
Incandescent
Lamp
COM (white)
CAP
240V (violet)
208V (orange)
120V (blk/yel)
X2
(white)
CAP
COM (White)
COM (White)
CAP
(blk/wht)
277V (black)
LAMP
X2
(White)
X1
(red)
LAMP
CAP
LAMP
IGNITOR
COM
(White)
Fig. C
Fig. B
COM (white)
COM (white)
COM (white)
Fig. D
Fig. F
Fig. E
LAMP (red)
480V(vio/wht)
(blk/wht)
277V (black)
CAP
LAMP
277V (black)
240V (violet)
COM (white)
120V (blk/yel)
COM (white)
COM (white)
Fig. I
Fig. H
480V (violet/wht)
X1
(red)
IGN
X3 (blue)
LAMP1
347V (org/wht)
X1
(red)
IGN
X3 (blue)
277V (black)
X2
(white)
LAMP2 (red/wht)
480V (vio/wht)
X3
(blue)
X1
(red)
IGNITOR
120V Aux
(blk/yel)
LAMP2 (red/wht)
240V (violet)
CAP
(blk/wht)
CAP (blk/wht)
CAP (blk/wht)
Max 250W
Incandescent
Lamp
CAP
CAP
COM (white)
COM (white)
LAMP (red)
X2
(white)
X2
(white)
CAP
COM (white)
CAP (blk/wht)
CAP (blk/wht)
Fig. J
COM (white)
Fig. L
Fig. K
LAMP (red)
480V (vio/wht)
347V (org/wht)
LAMP (red)
277V(black)
LAMP (red)
X3 (blue)
CAP
X1 (red)
IGNITO
R
IGNITOR
208V (orange)
CAP
CAP
(blk/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
COM (white)
Fig. O
Fig. N
480V (Vio/wht)
480V (vio/wht)
277V (black)
CA P
240V (violet)
CA P
120V (blk/yel)
208V (orange)
CAP
Fig. P
277V (black)
X3 (blue)
Fig. S
LAMP (red)
480V(vio/wht)
X3
(blue)
IGNITOR
LAMP2 (red/wht)
CAP (blk/wht)
CAP
(blk/wht)
CAP
COM (white)
CAP (blk/wht)
Fig. T
X1
(red)
CAP
COM (white)
COM (white)
Fig. U
CAP
(blk/wht)
CAP
LAMP
COM (white)
120V (blk/yel)
X1
(red)
IGN
LAMP
X2
(white)
LAMP
COM (white)
X1 (red)
IGNITO
R
Fig. R
X2
(white)
LAMP (red)
X3 (blue)
COM (White)
COM (White)
LAMP1
240V (violet)
CAP
(Optional)
Max 400W
Incandescent
Lamp
CAP
Fig. Q
480V (violet/wht)
120V(blk/yel)
CAP
(Blk/wht)
COM (white)
COM (white)
COM (white)
120V Aux (blk/yel)
CAP
120V (blk/yel)
COM (white)
LAMP
208V (orange)
240V (violet)
CAP
LAMP (red)
LAMP
277V (black)
CAP
(blk/wht )
CAP
LAMP
347V (org/wht)
CAP
(blk/wht)
X2
(White)
CAP
COM (white)
COM (white)
Fig. M
X1
(red)
240V (violet)
X2
(white)
CAP
(blk/wht)
X3
(blue)
277V (black)
LAMP
LAMP
IGNITOR
COM (white)
347V (org/wht)
X1
(red)
LAMP
X3
(blue)
277V (black)
120V (blk/yel)
LAMP
240V (violet)
X2
(white)
CAP
COM (white)
COM (white)
COM (white)
LAMP1
120V (blk/yel)
CAP
(blk/wht)
120V (blk/yel)
Fig. G
277V (black)
IGNITOR
208V (orange)
208V (orange)
120V (blk/yel)
X1
(red)
240V (violet)
LAMP
CAP
(blk/wht)
CAP
LAMP
347V (org/wht)
X3
(blue)
277V (black)
CAP
480V (vio/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
Fig. V
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 15
METAL HALIDE
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
(A)
Ballast
Dimensions
A(in) B(in)
Fig
Net
WT Wiring
(lbs) Diagram
Pacific
Ignitor/
Starter
1029
Class
Capacitor
EISA
(µF)
VAC
min
H
180
N
200
1500 Watt Lamp, ANSI Code M48
120/208 4MH1500SC
240/277
CWA
1602
4
13.5/7.7
6.6/5.9
4.1
6.3
6
30.0
F
n/a
32
525
EA
AA
AA
AA
120/208 4MH1500SCA
240/277
CWA
1550
4
13.1/7.5
6.5/5.7
4.5
6.9
6
28.1
F
n/a
32
525
FE
EE
BA
AA
CWA
1623
2
3.6
4.1
5.9
6
29.0
R
n/a
32
525
G
C
CWA
1540
6
7.5/6.5
5.7/4.5
3.3
4.7
7.2
6
30.5
P
n/a
32
525
GF
FE
E
CB
BA
A
480
120T
2MH1500SC/T
208/240
277/347
5MH1500SCA95*
480
120T
* Add "T" to denote 120V aux. tap option for standby lighting
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 6
For Ballast Dimensions Fig 6
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 16 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
BALLAST DIMENSIONS
Fig. 1
Fig. 2
"B"
5.750
"A"
4.375
4.250
5.375
3.875
0.195 Min. (8X)
Fig. 3
B max.
Fig. 4
4.50
A
3.30
3.75
∅0.175Min.(4X)
4.05
Fig. 5
Fig. 6
"B"
2 5/8"
B max. A
4.750
"A"
4.250
1 25/32"
4 Holes >= 0.175"
Cleared for #6 bolts
2 7/32" x 2 5/8" core
2 7/32"
4.375
3.875
2 3/16"
Fig. 7
Fig. 8
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 17
HIGH PRESSURE SODIUM
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
54
1
61
Max
Input
Current
Ballast
Dimensions
Net
WT
(lbs)
Wiring
Diagram
Pacific
Ignitor/
Starter
1029
Class
Capacitor
(µF)
VAC
min
H
180
N
200
HPSR1
n/a
n/a
A
A
HPSR1
n/a
n/a
A
A
5
280
AA
AA
AA
AA
n/a
n/a
A
A
7
280
BB
BB
7
300
A
(A)
A(in)
B(in)
Fig
1.0
0.6
1.8
7
1.1
S
1
1.0
0.8
2.0
7
1.7
S
68
4
1.0/0.6
0.5/0.4
1.0
2.5
1
3.5
A
HPSR1
83
1
1.7
1.3
2.5
7
2.0
S
HPSR1
1.5
3.0
1
4.6
A
HPSR1
1.9
3.2
1
5.8
B
HPSR1
35 Watt Lamp, ANSI Code S76
120
1HPS35SC120
R-NPF
50 Watt Lamp, ANSI Code S68
120
120/208
240/277
1HPS50SC120
4HPS50HXSCA
R-NPF
HX-HPF
70 Watt Lamp, ANSI Code S62
120
1HPS70SC120
R-NPF
120/208
240/277
4HPS70HXSCA
HX-HPF
95
4
1.4/0.8
0.7/0.6
480
2HPS70HXSC/T
HX-HPF
95
2
0.4
120T
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig. 1
For Ballast Dimensions Fig. 7
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig. 1
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 18 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
A
HID
WIRING DIAGRAMS
Fig. A
480V (vio/wht)
LAMP (Red)
CAP (blk/wht)
X3 (Blue)
LAMP (red)
277V (black)
X1
(Red)
X3
(blue)
240V (violet)
120V Aux
(blk/yel)
IGNITOR
208V (orange)
CAP
(blk/wht)
120V (blk/yel)
Max 150W
Incandescent
Lamp
COM (white)
CAP
240V (violet)
208V (orange)
120V (blk/yel)
X2
(white)
CAP
COM (White)
COM (White)
CAP
(blk/wht)
277V (black)
LAMP
X2
(White)
X1
(red)
LAMP
CAP
LAMP
IGNITOR
COM
(White)
Fig. C
Fig. B
COM (white)
COM (white)
COM (white)
Fig. D
Fig. F
Fig. E
LAMP (red)
480V(vio/wht)
(blk/wht)
277V (black)
CAP
LAMP
277V (black)
240V (violet)
COM (white)
120V (blk/yel)
COM (white)
COM (white)
Fig. I
Fig. H
480V (violet/wht)
X1
(red)
IGN
X3 (blue)
LAMP1
347V (org/wht)
X1
(red)
IGN
X3 (blue)
277V (black)
X2
(white)
LAMP2 (red/wht)
480V (vio/wht)
X3
(blue)
X1
(red)
IGNITOR
120V Aux
(blk/yel)
LAMP2 (red/wht)
240V (violet)
CAP
(blk/wht)
CAP (blk/wht)
CAP (blk/wht)
Max 250W
Incandescent
Lamp
CAP
CAP
COM (white)
COM (white)
LAMP (red)
X2
(white)
X2
(white)
CAP
COM (white)
CAP (blk/wht)
CAP (blk/wht)
Fig. J
COM (white)
Fig. L
Fig. K
LAMP (red)
480V (vio/wht)
347V (org/wht)
LAMP (red)
277V(black)
LAMP (red)
X3 (blue)
CAP
X1 (red)
IGNITO
R
IGNITOR
208V (orange)
CAP
CAP
(blk/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
COM (white)
Fig. O
Fig. N
480V (Vio/wht)
480V (vio/wht)
277V (black)
CA P
240V (violet)
CA P
120V (blk/yel)
208V (orange)
CAP
Fig. P
277V (black)
X3 (blue)
Fig. S
LAMP (red)
480V(vio/wht)
X3
(blue)
IGNITOR
LAMP2 (red/wht)
CAP (blk/wht)
CAP
(blk/wht)
CAP
COM (white)
CAP (blk/wht)
Fig. T
X1
(red)
CAP
COM (white)
COM (white)
Fig. U
CAP
(blk/wht)
CAP
LAMP
COM (white)
120V (blk/yel)
X1
(red)
IGN
LAMP
X2
(white)
LAMP
COM (white)
X1 (red)
IGNITO
R
Fig. R
X2
(white)
LAMP (red)
X3 (blue)
COM (White)
COM (White)
LAMP1
240V (violet)
CAP
(Optional)
Max 400W
Incandescent
Lamp
CAP
Fig. Q
480V (violet/wht)
120V(blk/yel)
CAP
(Blk/wht)
COM (white)
COM (white)
COM (white)
120V Aux (blk/yel)
CAP
120V (blk/yel)
COM (white)
LAMP
208V (orange)
240V (violet)
CAP
LAMP (red)
LAMP
277V (black)
CAP
(blk/wht )
CAP
LAMP
347V (org/wht)
CAP
(blk/wht)
X2
(White)
CAP
COM (white)
COM (white)
Fig. M
X1
(red)
240V (violet)
X2
(white)
CAP
(blk/wht)
X3
(blue)
277V (black)
LAMP
LAMP
IGNITOR
COM (white)
347V (org/wht)
X1
(red)
LAMP
X3
(blue)
277V (black)
120V (blk/yel)
LAMP
240V (violet)
X2
(white)
CAP
COM (white)
COM (white)
COM (white)
LAMP1
120V (blk/yel)
CAP
(blk/wht)
120V (blk/yel)
Fig. G
277V (black)
IGNITOR
208V (orange)
208V (orange)
120V (blk/yel)
X1
(red)
240V (violet)
LAMP
CAP
(blk/wht)
CAP
LAMP
347V (org/wht)
X3
(blue)
277V (black)
CAP
480V (vio/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
Fig. V
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 19
HIGH PRESSURE SODIUM
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
116
1
Max
Input
Current
Ballast
Dimensions
(A)
A(in)
B(in)
Fig
2.1
1.8
3.0
7
Net
WT
(lbs)
Wiring
Diagram
2.5
S
Pacific
Ignitor/
Starter
1029
Class
Capacitor
(µF)
VAC
min
H
180
n/a
n/a
A
N
200
100 Watt Lamp, ANSI Code S54
1HPS100SCA120
120
R-NPF
HPSR1
120/208
240/277
4HPS100HXSCA
HX-HPF
130
4
2.2/1.3
1.1/1.0
2.0
3.4
1
6.0
A
HPSR1
10
280
BB
BB
480
2HPS100HXSC/T
HX-HPF
132
2
0.6
2.0
3.4
1
6.2
C
HPSR1
10
280
C
4HPS100MRSC84
REG LAG
137
4
1.1/0.6
0.5/0.3
1.3
3.1
8
8.5
T
HPSR1
16
280
A
AA
AA
120T
120/240
277/480
A
AA
AA
150 Watt Lamp, ANSI Code S55
120
1HPS150SCA120
R-NPF
168
1
3.1
2.4
3.5
7
3.3
S
HPSR1
n/a
n/a
C
120/208
240/277
4HPS150HXSCA
HX-HPF
182
4
3.0/1.7
1.5/1.3
2.6
4.1
1
7.4
A
HPSR1
14
280
DC
BB
480
2HPS150HXSC/T
HX-HPF
188
2
0.8
3.0
4.3
1
8.6
D
HPSR1
14
280
F
B
4HPS150MRSC84
REG LAG
186
4
2.0/1.0
0.9/0.5
2.0
3.5
8
11.6
T
HPSR1
16
300
A
AA
A
A
AA
A
120T
120/240
277/480
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig 1
For Ballast Dimensions Fig 8
For Ballast Dimensions Fig 7
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 1
For Ballast Dimensions Fig 8
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 20 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
BALLAST DIMENSIONS
Fig. 1
Fig. 2
"B"
5.750
"A"
4.375
4.250
5.375
3.875
0.195 Min. (8X)
Fig. 3
B max.
Fig. 4
4.50
A
3.30
3.75
∅0.175Min.(4X)
4.05
Fig. 5
Fig. 6
"B"
2 5/8"
B max. A
4.750
"A"
4.250
1 25/32"
4 Holes >= 0.175"
Cleared for #6 bolts
2 7/32" x 2 5/8" core
2 7/32"
4.375
3.875
2 3/16"
Fig. 7
Fig. 8
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 21
HIGH PRESSURE SODIUM
Input
Volts
Cat.No.
Input
Power
(W)
# of
Taps
CWA
240
Circuit
Type
(V)
Max
Input
Current
Ballast
Dimensions
Net
WT
(lbs)
Wiring
Diagram
(A)
A(in)
B(in)
Fig
4
2.1/1.2
1.1/0.9
1.2
3.1
4
7.6
E
Pacific
Ignitor/
Starter
Capacitor
1029
Class
(µF)
VAC
min
H
180
N
200
HPS24
28
250
AA
AA
AA
AA
200 Watt Lamp, ANSI Code S66
120/208
240/277
4HPS200SAC
120/240
277
3HPS200MRSC83
REG LAG
252
3
2.6/1.3
1.17
2.3
4.3
8
13.3
J
HPS24
18
350
CB
B
AA
A
240/277
347/480
4HPS200MRSC74
REG LAG
252
4
1.3/1.1
0.9/0.6
2.3
4.3
8
13.3
K
HPS24
18
350
BB
BA
AA
AA
2.5/1.5
1.3/1.1
1.9
3.5
4
9.9
E
HPS24
35
240
CC
BB
AA
AA
2.0
3.9
4
10.7
I
HPS24
35
240
2.0
3.9
4
10.7
O
HPS24
35
240
DD
CC
C
DD
CC
CC
AA
AA
A
AA
AA
AA
250 Watt Lamp, ANSI Code S50
120/208
240/277
4HPS250SCA
CWA
300
4
5HPS250SCA
CWA
298
5
6HPS250SCA
CWA
298
6
120/277
347
3HPS250SCA03
CWA
298
3
2.6/1.1
0.9
2.0
3.9
4
10.7
M
HPS24
35
240
DC
C
AA
A
120/240
277
3HPS250MRSC83
REG LAG
308
3
2.7/1.3
1.2
2.4
4.2
3
16.5
J
HPS24
16
400
AA
A
AA
A
240/277
347/480
4HPS250MRSC74
REG LAG
304
4
1.3/1.2
0.9/0.7
2.4
4.2
3
16.5
K
HPS24
16
400
AA
AA
AA
AA
120/208
240/277
480
120/208
240/277
347/480
2.6/1.5
1.3/1.1
0.6
2.6/1.5
1.3/1.1
0.9/0.6
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
Welded Foot Bracket Dimensions
For Ballast Dimension Fig. 3
For Ballast Dimensions Fig 3, 4, 8
For Ballast Dimension Fig. 4,8
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 22 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
WIRING DIAGRAMS
Fig. A
480V (vio/wht)
LAMP (Red)
CAP (blk/wht)
X3 (Blue)
LAMP (red)
277V (black)
X1
(Red)
X3
(blue)
240V (violet)
120V Aux
(blk/yel)
IGNITOR
208V (orange)
CAP
(blk/wht)
120V (blk/yel)
Max 150W
Incandescent
Lamp
COM (white)
CAP
240V (violet)
208V (orange)
120V (blk/yel)
X2
(white)
CAP
COM (White)
COM (White)
CAP
(blk/wht)
277V (black)
LAMP
X2
(White)
X1
(red)
LAMP
CAP
LAMP
IGNITOR
COM
(White)
Fig. C
Fig. B
COM (white)
COM (white)
COM (white)
Fig. D
Fig. F
Fig. E
LAMP (red)
480V(vio/wht)
(blk/wht)
277V (black)
CAP
LAMP
277V (black)
240V (violet)
COM (white)
120V (blk/yel)
COM (white)
COM (white)
Fig. I
Fig. H
480V (violet/wht)
X1
(red)
IGN
X3 (blue)
LAMP1
347V (org/wht)
X1
(red)
IGN
X3 (blue)
277V (black)
X2
(white)
LAMP2 (red/wht)
480V (vio/wht)
X3
(blue)
X1
(red)
IGNITOR
120V Aux
(blk/yel)
LAMP2 (red/wht)
240V (violet)
CAP
(blk/wht)
CAP (blk/wht)
CAP (blk/wht)
Max 250W
Incandescent
Lamp
CAP
CAP
COM (white)
COM (white)
LAMP (red)
X2
(white)
X2
(white)
CAP
COM (white)
CAP (blk/wht)
CAP (blk/wht)
Fig. J
COM (white)
Fig. L
Fig. K
LAMP (red)
480V (vio/wht)
347V (org/wht)
LAMP (red)
277V(black)
LAMP (red)
X3 (blue)
CAP
X1 (red)
IGNITO
R
IGNITOR
208V (orange)
CAP
CAP
(blk/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
COM (white)
Fig. O
Fig. N
480V (Vio/wht)
480V (vio/wht)
277V (black)
CA P
240V (violet)
CA P
120V (blk/yel)
208V (orange)
CAP
Fig. P
277V (black)
X3 (blue)
Fig. S
LAMP (red)
480V(vio/wht)
X3
(blue)
IGNITOR
LAMP2 (red/wht)
CAP (blk/wht)
CAP
(blk/wht)
CAP
COM (white)
CAP (blk/wht)
Fig. T
X1
(red)
CAP
COM (white)
COM (white)
Fig. U
CAP
(blk/wht)
CAP
LAMP
COM (white)
120V (blk/yel)
X1
(red)
IGN
LAMP
X2
(white)
LAMP
COM (white)
X1 (red)
IGNITO
R
Fig. R
X2
(white)
LAMP (red)
X3 (blue)
COM (White)
COM (White)
LAMP1
240V (violet)
CAP
(Optional)
Max 400W
Incandescent
Lamp
CAP
Fig. Q
480V (violet/wht)
120V(blk/yel)
CAP
(Blk/wht)
COM (white)
COM (white)
COM (white)
120V Aux (blk/yel)
CAP
120V (blk/yel)
COM (white)
LAMP
208V (orange)
240V (violet)
CAP
LAMP (red)
LAMP
277V (black)
CAP
(blk/wht )
CAP
LAMP
347V (org/wht)
CAP
(blk/wht)
X2
(White)
CAP
COM (white)
COM (white)
Fig. M
X1
(red)
240V (violet)
X2
(white)
CAP
(blk/wht)
X3
(blue)
277V (black)
LAMP
LAMP
IGNITOR
COM (white)
347V (org/wht)
X1
(red)
LAMP
X3
(blue)
277V (black)
120V (blk/yel)
LAMP
240V (violet)
X2
(white)
CAP
COM (white)
COM (white)
COM (white)
LAMP1
120V (blk/yel)
CAP
(blk/wht)
120V (blk/yel)
Fig. G
277V (black)
IGNITOR
208V (orange)
208V (orange)
120V (blk/yel)
X1
(red)
240V (violet)
LAMP
CAP
(blk/wht)
CAP
LAMP
347V (org/wht)
X3
(blue)
277V (black)
CAP
480V (vio/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
Fig. V
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 23
HIGH PRESSURE SODIUM
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
Ballast
Dimensions
(A)
A(in)
B(in)
Fig
Net
WT
(lbs)
Wiring
Diagram
Pacific
Ignitor/
Starter
Capacitor
1029
Class
(µF)
VAC
min
H
180
N
200
310 Watt Lamp, ANSI Code S67
120
240/277
3HPS310MRSC83
REG
LAG
370
3
3.2
1.6/1.5
2.8
4.8
3
19.8
J
HPS24
17
460
B
AA
A
AA
240/277
347/480
4HPS310MRSC74
REG
LAG
372
4
1.6/1.4
1.1/0.8
2.8
4.8
3
20.0
K
HPS24
17
460
AA
AA
AA
AA
400 Watt Lamp, ANSI Code S51
120/208
240/277
4HPS400SCA
CWA
453
4
3.8/2.2
1.9/1.7
2.3
4.2
4
12.4
E
HPS24
55
240
DD
DD
AA
AA
120/208
240/277
4HPS400SAC
CWA
455
4
3.9/2.3
2/1.7
2.3
4.2
4
13.1
E
HPS24
55
240
DD
DC
AA
AA
120/277
347
3HPS400SAC03
CWA
462
3
3.9/1.7
1.4
2.3
4.3
4
13.0
M
HPS24
55
240
ED
C
AA
A
480
120/208
240/277
480
120/208
240/277
480
120/208
240/277
347/480
120/208
240/277
347/480
120/240
277
240/277
347/480
1HPS400SCA48T
CWA
450
1
2.6
4.7
4
13.5
L
HPS24
55
240
5HPS400SCA
CWA
450
5
2.6
4.7
4
13.5
I
HPS24
55
240
5HPS400SAC
CWA
462
5
2.3
4.3
4
13.0
I
HPS24
55
240
6HPS400SCA
CWA
450
5
2.6
4.7
4
13.5
O
HPS24
55
240
6HPS400SAC
CWA
400
6
2.3
4.3
4
13.0
O
HPS24
55
240
3HPS400MRSC83
REG
LAG
481
3
3.5
5.4
3
24.2
J
HPS24
24
430
4HPS400MRSC74
REG
LAG
481
4
0.9
3.8/2.2
1.9/1.6
0.9
3.9/2.3
2.0/1.7
1.0
3.8/2.2
1.9/1.6
1.3/0.9
3.9/2.3
2.0/1.7
1.4/1.0
4.3/2.1
1.8
2.2/1.9
1.5/1.1
3.5
5.4
3
24.6
K
HPS24
24
430
D
EE
ED
D
EE
DD
C
EE
ED
DD
EE
DD
CC
CB
B
AA
AA
A
A
AA
AA
A
AA
AA
AA
AA
AA
AA
AA
AA
AA
A
AA
AA
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as
necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 3
For Ballast Dimensions Fig 3, 4
For Ballast Dimensions Fig 4
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 24
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
BALLAST DIMENSIONS
Fig. 1
Fig. 2
"B"
5.750
"A"
4.375
4.250
5.375
3.875
0.195 Min. (8X)
Fig. 3
B max.
Fig. 4
4.50
A
3.30
3.75
∅0.175Min.(4X)
4.05
Fig. 5
Fig. 6
"B"
2 5/8"
B max. A
4.750
"A"
4.250
1 25/32"
4 Holes >= 0.175"
Cleared for #6 bolts
2 7/32" x 2 5/8" core
2 7/32"
4.375
3.875
2 3/16"
Fig. 7
Fig. 8
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 25
HIGH PRESSURE SODIUM
Input
Volts
Cat.No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
Ballast
Dimensions
(A)
A(in)
B(in)
Fig
Net
WT
(lbs)
Wiring
Diagram
Pacific
Ignitor/
Starter
1029
Class
Capacitor
(µF)
VAC
min
H
180
N
200
1000 Watt Lamp, ANSI Code S52
120/208
240/277
4HPS1000SAA
CWA
1060
4
8.8/5.1
4.4/3.9
4.3
6.3
6
26.0
E
HPS1K
26
525
EE
EE
AA
AA
120/208
240/277
4HPS1000SC
CWA
1150
4
9/5.2
4.5/4.0
3.7
6.1
6
28.0
E
HPS1K
26
525
AA
AA
AA
AA
120/277
347
120/208
240/277
480
120/208
240/277
347/480
3HPS1000SCA03
CWA
1130
3
4.1
6.2
6
26.3
M
HPS1K
26
525
5HPS1000SCA
CWA
1070
5
4.1
6.1
6
26.0
I
HPS1K
26
525
6HPS1000SCA
CWA
1130
5
9.7/4.2
3.3
9.7/5.6
4.9/4.2
2.4
9.7/5.6
4.9/4.2
3.3/2.4
4.1
6.2
6
26.3
O
HPS1K
26
525
ED
D
ED
DD
C
ED
DD
DC
AA
A
AA
AA
A
AA
AA
AA
Ordering Information (Add suffix for options)
- WB With welded foot bracket
- I With ignitor
- DC With dry film capacitor, subject to availability
- OC With oil filled capacitor, subject to availability
- K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.)
Contact Manufacturer’s rep for specialty bracket/accessory availability
Kit Bracket Dimensions
For Ballast Dimensions Fig 6
Welded Foot Bracket Dimensions
For Ballast Dimensions Fig 6
Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Page 26
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
WIRING DIAGRAMS
Fig. A
480V (vio/wht)
LAMP (Red)
CAP (blk/wht)
X3 (Blue)
LAMP (red)
277V (black)
X1
(Red)
X3
(blue)
240V (violet)
120V Aux
(blk/yel)
IGNITOR
208V (orange)
CAP
(blk/wht)
120V (blk/yel)
Max 150W
Incandescent
Lamp
COM (white)
CAP
240V (violet)
208V (orange)
120V (blk/yel)
X2
(white)
CAP
COM (White)
COM (White)
CAP
(blk/wht)
277V (black)
LAMP
X2
(White)
X1
(red)
LAMP
CAP
LAMP
IGNITOR
COM
(White)
Fig. C
Fig. B
COM (white)
COM (white)
COM (white)
Fig. D
Fig. F
Fig. E
LAMP (red)
480V(vio/wht)
(blk/wht)
277V (black)
CAP
LAMP
277V (black)
240V (violet)
COM (white)
120V (blk/yel)
COM (white)
COM (white)
Fig. I
Fig. H
480V (violet/wht)
X1
(red)
IGN
X3 (blue)
LAMP1
347V (org/wht)
X1
(red)
IGN
X3 (blue)
277V (black)
X2
(white)
LAMP2 (red/wht)
480V (vio/wht)
X3
(blue)
X1
(red)
IGNITOR
120V Aux
(blk/yel)
LAMP2 (red/wht)
240V (violet)
CAP
(blk/wht)
CAP (blk/wht)
CAP (blk/wht)
Max 250W
Incandescent
Lamp
CAP
CAP
COM (white)
COM (white)
LAMP (red)
X2
(white)
X2
(white)
CAP
COM (white)
CAP (blk/wht)
CAP (blk/wht)
Fig. J
COM (white)
Fig. L
Fig. K
LAMP (red)
480V (vio/wht)
347V (org/wht)
LAMP (red)
277V(black)
LAMP (red)
X3 (blue)
CAP
X1 (red)
IGNITO
R
IGNITOR
208V (orange)
CAP
CAP
(blk/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
COM (white)
Fig. O
Fig. N
480V (Vio/wht)
480V (vio/wht)
277V (black)
CA P
240V (violet)
CA P
120V (blk/yel)
208V (orange)
CAP
Fig. P
277V (black)
X3 (blue)
Fig. S
LAMP (red)
480V(vio/wht)
X3
(blue)
IGNITOR
LAMP2 (red/wht)
CAP (blk/wht)
CAP
(blk/wht)
CAP
COM (white)
CAP (blk/wht)
Fig. T
X1
(red)
CAP
COM (white)
COM (white)
Fig. U
CAP
(blk/wht)
CAP
LAMP
COM (white)
120V (blk/yel)
X1
(red)
IGN
LAMP
X2
(white)
LAMP
COM (white)
X1 (red)
IGNITO
R
Fig. R
X2
(white)
LAMP (red)
X3 (blue)
COM (White)
COM (White)
LAMP1
240V (violet)
CAP
(Optional)
Max 400W
Incandescent
Lamp
CAP
Fig. Q
480V (violet/wht)
120V(blk/yel)
CAP
(Blk/wht)
COM (white)
COM (white)
COM (white)
120V Aux (blk/yel)
CAP
120V (blk/yel)
COM (white)
LAMP
208V (orange)
240V (violet)
CAP
LAMP (red)
LAMP
277V (black)
CAP
(blk/wht )
CAP
LAMP
347V (org/wht)
CAP
(blk/wht)
X2
(White)
CAP
COM (white)
COM (white)
Fig. M
X1
(red)
240V (violet)
X2
(white)
CAP
(blk/wht)
X3
(blue)
277V (black)
LAMP
LAMP
IGNITOR
COM (white)
347V (org/wht)
X1
(red)
LAMP
X3
(blue)
277V (black)
120V (blk/yel)
LAMP
240V (violet)
X2
(white)
CAP
COM (white)
COM (white)
COM (white)
LAMP1
120V (blk/yel)
CAP
(blk/wht)
120V (blk/yel)
Fig. G
277V (black)
IGNITOR
208V (orange)
208V (orange)
120V (blk/yel)
X1
(red)
240V (violet)
LAMP
CAP
(blk/wht)
CAP
LAMP
347V (org/wht)
X3
(blue)
277V (black)
CAP
480V (vio/wht)
120V (blk/yel)
X2
(white)
COM (white)
COM (white)
Fig. V
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 27
IGNITOR / STARTER
Lamp
Compatibility
Cat. No.
Pulse
Voltage
(kV)*
Pulse
Width
(µS)**
Dimensions
Net
WT
Ballast
To Lamp
Distance
Max
Case
Temp.
A
(in)
B
(in)
C
(in)
Ф or D
(in)
Fig
(lbs)
(ft)
(°C)
Ignitor for Metal Halide Lamps
50-150W
MHR1
3~4
≥1
2.6
14
n/a
1.3
9
0.3
25
105
175-450W
MHR3
3~4
≥1
2.6
14
n/a
1.3
9
0.3
10
105
750W
MHR2
3~4
≥1.5
2.9
14
2
1.3
10
0.5
15
105
1000W
HPS1K
3~5
≥4
2.4
2.9
14
40
11
0.5
15
105
Ignitor for Metal Halide Lamps
35-150W
HPSR1
2.5~4
≥1
2.6
14
n/a
33
9
0.3
10
105
200-400W
HPS24
2.5~4
≥1
2.6
14
n/a
33
9
0.3
10
105
1000W
HPS1K
3~5
≥4
2.4
2.9
14
40
11
0.5
15
105
Net
WT
Ballast
To Lamp
Distance
Max
Case
Temp.
* With a dummy lamp load of 20pF
** At 2250 volts for HPSR1 and HPS24; 2700 volts for MHR1, MHR3, MHR2 and HPS1K
Lamp
Compatibility
Cat. No.
Pulse
Voltage
(kV)*
Pulse
Width
(µS)**
Dimensions
A
(in)
B
(in)
C
(in)
Ф or D
(in)
Fig
(lbs)
(ft)
(°C)
2.9
14
2
1.3
10
0.5
25
105
Auto Shut Off Ignitor for Metal Halide Lamps
35-400W
MHR1-AS
3.0~4.0
≥1
Auto Shut Off Ignitor for High Pressure Sodium Lamps
35-150W
HPSR1-AS
2.5~4.0
≥1
2.9
14
2
1.3
10
0.5
10
105
200-400W
HPS24-AS
2.5~4.0
≥1
2.9
14
2
1.3
10
0.5
10
105
3.0~4.0
≥3
2.9
14
2
1.3
10
0.5
50
105
Long Range Ignitor
175W-750W
MHR4-LR
* With a dummy lamp load of 20pF
** At 2250 volts for HPSR1-AS and HPS24-AS; 2700 volts for MHR1-AS, MHR4-LR
Page 28
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
IGNITOR/STARTER
Fig. 9
Fig. 10
Fig. 11
CAPACITOR/IGNITOR BRACKET DIMENSIONS
Note: Ignitor Dimensions in millimeters, where 1milimeter = 1/25.4 inch
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 29
METAL HALIDE - F.CAN
Input
Volts
Cat. No.
Circuit
Type
(V)
Input
Power
(W)
# of
Taps
Max
Input
Current
Net
WT
Case
Dimensions
1029
Class
Wiring
Diagram
Ignitor/Capacitor
(A)
L
(in)
W
(in)
H
(in)
M
(in)
Fig
(lbs)
2
1.3/0.5
11.8
3.2
2.7
11.1
12
8.3
W
N/A (Integral)
AA
A
105
50 Watt Lamp, ANSI Code M110, M148
120/277
FP50HXSAA92
HX-HPF
64
70 Watt Lamp, ANSI Code M98, M143
120/277
FP70HXSCA92
HX-HPF
85
2
1.7/0.7
11.8
3.2
2.7
11.1
12
9.2
W
N/A (Integral)
AA
120/347
FP70HXSCA52C
HX-HPF
85
2
1.7/0.6
11.8
3.2
2.7
11.1
12
9.5
X
N/A (Integral)
AA
100 Watt Lamp, ANSI Code M90, M140
120/277
FP100HXSCA92
HX-HPF
121
2
2.5/1.1
11.8
3.2
2.7
11.1
12
9.4
W
N/A (Integral)
AA
120/347
FP100HXSCA52C
HX-HPF
120
2
2.5/0.9
11.8
3.2
2.7
11.1
12
9.3
X
N/A (Integral)
AA
150 Watt Lamp, ANSI Code M102, M142
120/277
FP150HXSCA92
HX-HPF
170
2
3.4/1.5
11.8
3.2
2.7
11.1
12
10.1
W
N/A (Integral)
AA
120/347
FP150HXSCA52C
HX-HPF
176
2
3.4/1.2
11.8
3.2
2.7
11.1
12
10.2
X
N/A (Integral)
AA
175 Watt Lamp, ANSI Code M57
120/277
FM175SC92
CWA
200
2
2.5/1.1
11.8
3.2
2.7
11.1
12
11.8
W
N/A (Integral)
AA
120/347
FM175SC52C
CWA
200
2
2.5/0.9
11.8
3.2
2.7
11.1
12
11.6
X
N/A (Integral)
AA
250 Watt Lamp, ANSI Code M58
120/277
FM250SC92
CWA
290
2
3.1/1.4
14.3
3.2
2.6
11.1
12
14.0
W
N/A (Integral)
AA
120/347
FM250SC52C
CWA
295
2
3.4/1.2
14.3
3.2
2.6
11.1
12
14.1
X
N/A (Integral)
AA
400 Watt Lamp, ANSI Code M59
120/277
FM400SC92
CWA
460
2
5.1/2.2
19.2
3.2
2.4
18.6
12
19.6
W
N/A (Integral)
AA
120/347
FM400SC52C
CWA
460
2
5.2/1.9
19.2
3.2
2.4
18.6
12
19.8
X
N/A (Integral)
AA
CASE DIMENSIONS
WIRING DIAGRAMS
Fig. W
Fig. 12
Fig. X
Page 30
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
HID
HIGH PRESSURE SODIUM - FCAN
Input
Volts
Circuit
Type
Cat. No.
(V)
Input
Power
(W)
# of
Taps
66
2
Max
Input
Current
Net
WT
Case
Dimensions
1029
Class
Wiring
Diagram
Ignitor/Capacitor
(A)
L
(in)
W
(in)
H
(in)
M
(in)
Fig
(lbs)
1.0/0.5
11.8
3.2
2.7
11.1
12
8.7
W
N/A (Integral)
AA
A
105
50 Watt Lamp, ANSI Code S68
120/277
FS50HXSCA92
HX-HPF
70 Watt Lamp, ANSI Code S62
‘
120/277
FS70HXSCA92
HX-HPF
91
2
1.4/0.64
11.8
3.2
2.7
11.1
12
9.4
W
N/A (Integral)
AA
120/347
FS70HXSCA52C
HX-HPF
91
2
1.5/0.5
11.8
3.2
2.7
11.1
12
9.7
X
N/A (Integral)
AA
100 Watt Lamp, ANSI Code S54
120/277
FS100HXSCA92
HX-HPF
123
2
1.9/0.9
11.8
3.2
2.7
11.1
12
9.7
W
N/A (Integral)
AA
120/347
FS100HXSCA52C
HX-HPF
123
2
1.9/0.7
11.8
3.2
2.7
11.1
12
9.7
X
N/A (Integral)
AA
150 Watt Lamp, ANSI Code S55
120/277
FS150HXSCA92
HX-HPF
173
2
2.6/1.2
11.8
3.2
2.7
11.1
12
11.0
W
N/A (Integral)
AA
120/347
FS150HXSCA52C
HX-HPF
170
2
2.6/1
11.8
3.2
2.7
11.1
12
11.0
X
N/A (Integral)
AA
CASE DIMENSIONS
WIRING DIAGRAMS
Fig. W
Fig. 12
Fig. X
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Page 31
STEPDOWN AUTOTRANSFORMERS-SLIMLINE
Volts
Input
(V)
Max.
Input
Current
(A)
Volts
Output
(V)
MTM00503424C
347
0.2
MTM00504824C
480
-
347
0.2
480
0.1
Max
Load
( V.A. )
Cat. No.
50
50
Case
Dimensions
Full Load
Net
WT
(lbs)
Wiring
Diagram
Eff.
(%)
THD
(%)
Power
Factor
A
(in)
B
(in)
Fig
240
95
11.6
0.98
2.1
1.2
13
0.7
A1
240
92
11.6
0.98
-
-
13
-
A2
94
12.1
0.98
92
11.6
0.98
3.0
2.1
13
1.2
A3
50
MTM00506224C
100
MTM01003424C
347
0.3
240
96
12.1
0.99
3.2
2.4
13
1.3
A1
MTM01004824C
480
-
240
93
11.7
0.99
-
-
13
-
A2
347
0.3
95
12.1
0.99
480
0.2
93
11.7
0.99
4.0
3.1
13
1.7
A3
100
100
MTM01006224C
240
240
215
MTM02153424C
347
-
240
93
15.0
0.98
-
-
13
-
A1
215
MTM02154824C
480
-
240
91
15.0
0.98
-
-
13
-
A2
347
0.7
93
15.0
0.98
480
0.5
91
15.0
0.98
5.6
4.7
13
2.5
A3
215
MTM02156224C
240
*Contact Manufacturer for Additonal Information
CASE DIMENSIONS
B
MAX
Pacific Ballast Stepdown Autotransformers Model Nunbers
1.62"
A
1.31"
MTM
0050
62
24C
Ⅰ
Ⅱ
Ⅲ
Ⅳ
MTM=
Magnetic
Autotransformers
Max V.A.Load
50-215
Input Volt Tap Code=
34(347)
48(480)
62(347,480)
Fig. 13
WIRING DIAGRAMS
Fig. A1
Page 32
Fig. A2
Fig. A3
Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above.
Ouput Volt Tap Code=
24(240)
12(120)Pending
Note
McWong International, Inc
1921 Arena Blvd
Sacramento, California 95834
USA
Tel: 916-371-8080
Fax: 916-371-6666
www.McWonginc.com