HID Catalog About us For over 25 years, McWong International, Inc. has been bridging the best of East and West in order to achieve for our valued customers an unparalleled mix of innovation, quality, and service. A California corporation, McWong has grown to become a leader in the design and manufacture of high quality lighting control equipment and related electrical components. Our teams on both sides of the Pacific take great pride in the fact that the majority of our growth comes from organic nurturing of business with long-term, world-class customers. Reliable, competitive products paired with committed customer service year in and year out have enabled sustained growth over more than two decades. Today, the pace of technological change has quickened and competition continues to intensify. We are meeting these challenges through heightened investment in capable individuals, promising technologies and advanced manufacturing facilities. McWong’s disciplined approach to quality management, customer service, and cost control ensures that we are well-poised to accelerate our pace of growth as we partner with our stakeholders to achieve a brighter, more sustainable, more successful future. Pacific Ballast® HID For more than a decade, major US customers have come to rely on McWong’s Pacific Ballast HID. In an unrelenting process of ongoing improvement, we strive to ensure delivery of our core values in every product . Innovation: One of the coolest, quietest lines in the industry Broad product offering – over 350 UL recognized models and growing UL 200˚C Insulation System standard production for all core & coil units EISA compliant offering one of the broadest in the market Enhanced ANSI waveform compliance testing Quality: ISO9001 certified production facilities Automated In-line Testing with individually trackable date codes on 100% of our ballasts Quality construction, precision coil windings Automated Vacuum Pressure Impregnation Automated Arc Welding ensures tight, noise-free cores Service: Custom design capabilities Expanded warehousing to support North American customers Unsurpassed after sales service and support New / Unique Offerings: · · · · · F-Can line — 50, 70, 100, 150W — watch for more models coming soon. Magnetic Regulated Lag “Mag Reg” — HPS 70, 100, 150, 200, 310, 250, 400W and MP 175, 400W Bi-level Dimming Compatible line New offering of Ultra-high efficiency ballasts. (Efficiencies >90%) — Linear Reactors and special designed Pulse-CWA units. Auto-shutoff Ignitors now available; Long-Range Ignitors coming soon... This catalog offers just a partial list of our common items. Contact McWong for additional SKUs. HID Contents Pacific Ballast Model Number Information ……………………02 Warranty ………………………………………………………03 Metal Halide Ballasts (Pulse and Standard) ……………………04 High Pressure Sodium Ballasts…………………………………18 Ignitors (Starters) ………………………………………………28 F.CAN HID Ballasts………………………………………………30 Stepdown Autotransformers …………………………………32 Specifications subject to change without notice. Page 01 Pacific Ballast® HID Model Numbers 4 2 5 1 1 3 F MP MH MH HPS MP HPS M or P or S Ⅰ Ⅱ 400 70 250 1000 175 310 50 Ⅲ R MR HX SAA SC SCA SCA SC SC SAA 48 277 63 92 Ⅳ Ⅴ Ⅵ HX Coil : Precision wound, Al/Al Cu/Al Cu/Cu Cu/Cu/Cu Input Volt Tap Code: 12 (120) 27 (277) 48 (480) 52 (120, 347) 53 (240, 277, 347) 62 (347, 480) 63 (240, 277, 480) 72 (240, 480) 73 (277, 347, 480) 74 (240, 277, 347, 480) 82 (120, 240) 83 (120, 240, 277) 84 (120, 240, 277, 480) 92 (120, 277) Blank = default, see position ‘A’ notes. /T -PS T -TAB Ⅶ Suffix Codes: /T (T) = 120T; -TAB = fast-on quick connect tabs in leiu of lead wires; -PS = MH pulse start, non-EISA compliant. Reference add’l ordering suffices in the footnotes of each spec sheet and/or catalog listing. Circuit Type: Blank (default) = CWA HX = High Reactance MR = MagReg R = Linear Reactor Lamp Watts (Nominal): 35 – 2000W F=F.CAN or Number of Input Taps: 1, 2, 3, 4, 5, 6; if no voltage tap suffix code appears in position ‘F’, then default applies: ‘5’ = 120/208/240/277/480 ‘4’ = 120/208/240/277 ‘2’ = Dual 480V/120T. Page 02 Lamp Type: HPS = High Pressure Sodium (F.CAN=FS) MH (absent of ‘-PS’ suffix) = Standard Metal Halide (probe/switch start); (F.CAN=FM) MH (followed by ‘-PS’ suffix) = non-EISA Pulse Start Metal Halide; (F.CAN=FP) MP = EISA Pulse Start Metal Halide HID PACIFIC BALLAST® LIMITED WARRANTY McWong International, Inc. ("MCWONG"), 2544 Industrial Blvd., West Sacramento, California 95691, warrants its lamp ballasts to be free from defect in material and workmanship from the date of manufacture by MCWONG for the following time periods: High Intensity Discharge (HID)................................................ 2 Years Electromagnetic Fluorescent (Residential)......................... 2 Years Electromagnetic Fluorescent (Commercial)....................... 3 Years Electronic Fluorescent (Residential)...................................... 2 Years Electronic Fluorescent (Commercial).................................... 5 Years Date codes for electromagnetic ballast(s) are stamped in the underside of the ballast can. Date codes for electronic ballast(s) can be found on the label and/or stamped into the underside of the can. Date codes for HID Ballast(s) can be found imprinted on the end of the lamination and/or on date code label applied to coils. Pacific Ballast® labels show our toll free number – 888-600-9188 allowing convenient contact directly with a qualified technical support administrator. Warranty claims may also be submitted online by visiting www.mcwonginc.com and clicking on Technical Support / Warranty. This warranty is not applicable to any ballast subjected to abnormal stresses. Validity of this warranty is also conditioned upon proper storage, installation, use and maintenance. This warranty is not applicable to any PACIFIC BALLAST® product not installed and operated in accordance with: The National Electrical Code (NEC) The standards for safety of Underwriter's Laboratories, Inc. (UL) The standards of the American National Standards Institute (ANSI) Relevant electrical ratings and Maximum Temperature Ratings The specific instructions provided by MCWONG for the installation of the product(s) If it appears that the product does not meet the warranty specified above, the Purchaser must notify MCWONG of its claim in writing at the address above and, after receiving proper authorization, must promptly return the product(s) at purchaser's expense to MCWONG – unless prior arrangement has been made with MCWONG for other RGA dispositioning. MCWONG shall correct any defects, at MCWONG's option, by either repairing any defective part(s), by making available a replacement ballast, or by extending a credit in the amount of the ballast purchase price. The standards and conditions of any tests concerning any PACIFIC BALLAST® claimed to have not performed to this warranty shall be mutually agreed upon in writing and MCWONG shall be notified of, and may be represented at any such tests. This express limited warranty is extended by MCWONG only to the original or first end-user purchaser. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND THE AFOREMENTIONED BALLAST WARRANTY PERIOD. This warranty is exclusive of all other statutory, written or oral warranties and no other warranties of any kind, statutory or otherwise, are given or herein expressed. Under no circumstances, whether as a result if breach of contract, breach of warranty, tort, strict liability or otherwise, will MCWONG be liable for consequential, incidental, special or exemplary damages, including, but not limited to, loss of profits, loss of use or damage to any property or equipment, cost of capital, cost of substitute products, facilities or services, downtime costs or claims of any kind or any loss or damage arising out of, resulting from, or concerning any aspect of this agreement of from the products or services furnished. Page 03 METAL HALIDE Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps Max Input Current (A) Ballast Dimensions A(in) B(in) Fig Net WT Wiring (lbs) Diagram Pacific Ignitor/ Starter 1029 Class Capacitor EISA (µF) VAC min H 180 N 200 50 Watt Lamp, ANSI Code M110, M148 120/208 240/277 4MH50HXSAA HX-HPF 70 4 1.2/0.8 0.6/0.5 1.0 2.5 1 3.1 A MHR1 6 280 AA AA AA AA 70 Watt Lamp, ANSI Code M98, M143 120/208 240/277 4MH70HXSCA HX-HPF 85 4 1.6/0.9 0.8/0.7 1.5 2.9 1 4.5 A MHR1 8 280 AA AA AA AA 480 2MH70HXSC/T HX-HPF 88 2 0.5 1.5 2.8 1 5.0 B MHR1 8 280 C A 120T 100 Watt Lamp, ANSI Code M90, M140 120/208 240/277 4MH100HXSCA HX-HPF 120 4 2.4/1.4 1.2/1.1 1.6 3.0 1 4.8 A MHR1 12 280 BA AA AA AA 480 2MH100HXSC/T HX-HPF 120 2 0.6 1.6 2.8 1 5.0 C MHR1 12 280 C A 120T 150 Watt Lamp, ANSI Code M102, M142 120/208 240/277 4MH150HXSCA HX-HPF 182 4 3.4/2.0 1.7/1.5 2.3 3.8 1 6.8 A MHR1 16 280 BB AA AA AA EX 480 2MH150HXSC/T HX-HPF 185 2 0.9 2.3 3.9 1 7.0 D MHR1 16 280 E A EX 4MP150SCA PS-CWA 186 4 1.6/1.0 0.8/0.7 2.4 3.9 1 6.9 E HPS24 16 330 CC CB AA AA EX 120T 120/208 240/277 EX: Meets EISA under exception for >50°C ambient temperature for wet/damp location fixture Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact McWong for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig 1 Welded Foot Bracket Dimensions For Ballast Dimensions Fig 1 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 04 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID BALLAST DIMENSIONS Fig. 1 Fig. 2 "B" 5.750 "A" 4.375 4.250 5.375 3.875 0.195 Min. (8X) Fig. 3 B max. Fig. 4 4.50 A 3.30 3.75 ∅0.175Min.(4X) 4.05 Fig. 5 Fig. 6 "B" 2 5/8" B max. A 4.750 "A" 4.250 1 25/32" 4 Holes >= 0.175" Cleared for #6 bolts 2 7/32" x 2 5/8" core 2 7/32" 4.375 3.875 2 3/16" Fig. 7 Fig. 8 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 05 METAL HALIDE Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps Max Input Current (A) Ballast Dimensions A(in) B(in) Fig Net WT Wiring (lbs) Diagram Pacific Ignitor/ Starter 1029 Class Capacitor EISA (µF) VAC min H 180 N 200 175 Watt Lamp, ANSI Code M57; or 150 Watt Lamp, ANSI Code M107 120/208 240/277 4MH175SCA CWA 207 4 1.9/1.1 1.0/0.8 2.4 3.8 1 6.8 F n/a 10 400 BC CC AA AA 120 277/347 3MH/MV175SCC CWA 207 3 1.7 0.9/0.8 2.4 4.0 1 7.8 G n/a 10 400 B CC A AA 120/208 240/277 5MH175SCA 480 CWA 210 5 1.9/1.1 0.9/0.8 0.5 2.4 4.1 1 6.9 H n/a 10 400 CB BB A AA AA A 175 Watt Lamp, ANSI Code M137, M152 (Pulse Start) 120/208 240/277 4MH175SAA-PS PS-CWA 202 4 1.8/1.0 0.9/0.8 2.6 4.0 1 6.9 E MHR3 10 400 CC BB AA AA 120/208 240/277 4MP175SCA4 PS-CWA 203 4 1.8/1.0 0.9/0.8 1.9 3.9 4 10.0 E MHR3 13 330 BB BB AA AA Y 120/208 240/277 4MP175SC PS-CWA 196 4 1.8/1.0 0.9/0.7 3.1 4.3 2 10.1 E MHR3 13 350 AA AA AA AA Y 120/208 240/277 5MH175SC-PS 480 PS-CWA 210 5 2.0/1.2 1.1/0.9 0.6 2.4 3.5 1 7.8 I MHR3 10 400 BB BB C AA AA A PS-CWA 201 1 0.4 3.2 4.5 1 9.5 U MHR3 11 400 C A 1.7 3.4 3 12.6 J MHR1 17 330 A AA A AA 480 1MP175SC48 REG LAG 215 3 1.9 1.0/0.8 240/277 347/480 4MP175MRSC74* REG LAG 215 4 1.0/0.8 0.7/0.5 1.7 3.4 3 12.6 K MHR1 17 330 AA AA AA AA 120 240/277 3MP175MRSC83 Y 200 Watt Lamp, ANSI Code M136 (Pulse Start) 120/208 240/277 4MP200SC3 PS-CWA 215 4 2.1/1.2 1.1/0.9 3.0 4.4 1 9.3 E MHR3 13 330 AA AA AA AA Y 120/208 240/277 4MP200SCA PS-CWA 235 4 1.8/1.1 0.9/0.8 2.0 3.7 4 10.2 E MHR3 16 300 AA AA AA AA Y * Add "T" to denote 120V aux. tap option for standby lighting Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig 1, 2 Welded Foot Bracket Dimensions For Ballast Dimensions Fig 1, 2 For Ballast Dimensions Fig. 3, 4 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch For Ballast Dimensions Fig 3 For Ballast Dimensions Fig 4 Page 06 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID WIRING DIAGRAMS Fig. A 480V (vio/wht) LAMP (Red) CAP (blk/wht) X3 (Blue) LAMP (red) 277V (black) X1 (Red) X3 (blue) 240V (violet) 120V Aux (blk/yel) IGNITOR 208V (orange) CAP (blk/wht) 120V (blk/yel) Max 150W Incandescent Lamp COM (white) CAP 240V (violet) 208V (orange) 120V (blk/yel) X2 (white) CAP COM (White) COM (White) CAP (blk/wht) 277V (black) LAMP X2 (White) X1 (red) LAMP CAP LAMP IGNITOR COM (White) Fig. C Fig. B COM (white) COM (white) COM (white) Fig. D Fig. F Fig. E LAMP (red) 480V(vio/wht) (blk/wht) 277V (black) CAP LAMP 277V (black) 240V (violet) COM (white) 120V (blk/yel) COM (white) COM (white) Fig. I Fig. H 480V (violet/wht) X1 (red) IGN X3 (blue) LAMP1 347V (org/wht) X1 (red) IGN X3 (blue) 277V (black) X2 (white) LAMP2 (red/wht) 480V (vio/wht) X3 (blue) X1 (red) IGNITOR 120V Aux (blk/yel) LAMP2 (red/wht) 240V (violet) CAP (blk/wht) CAP (blk/wht) CAP (blk/wht) Max 250W Incandescent Lamp CAP CAP COM (white) COM (white) LAMP (red) X2 (white) X2 (white) CAP COM (white) CAP (blk/wht) CAP (blk/wht) Fig. J COM (white) Fig. L Fig. K LAMP (red) 480V (vio/wht) 347V (org/wht) LAMP (red) 277V(black) LAMP (red) X3 (blue) CAP X1 (red) IGNITO R IGNITOR 208V (orange) CAP CAP (blk/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) COM (white) Fig. O Fig. N 480V (Vio/wht) 480V (vio/wht) 277V (black) CA P 240V (violet) CA P 120V (blk/yel) 208V (orange) CAP Fig. P 277V (black) X3 (blue) Fig. S LAMP (red) 480V(vio/wht) X3 (blue) IGNITOR LAMP2 (red/wht) CAP (blk/wht) CAP (blk/wht) CAP COM (white) CAP (blk/wht) Fig. T X1 (red) CAP COM (white) COM (white) Fig. U CAP (blk/wht) CAP LAMP COM (white) 120V (blk/yel) X1 (red) IGN LAMP X2 (white) LAMP COM (white) X1 (red) IGNITO R Fig. R X2 (white) LAMP (red) X3 (blue) COM (White) COM (White) LAMP1 240V (violet) CAP (Optional) Max 400W Incandescent Lamp CAP Fig. Q 480V (violet/wht) 120V(blk/yel) CAP (Blk/wht) COM (white) COM (white) COM (white) 120V Aux (blk/yel) CAP 120V (blk/yel) COM (white) LAMP 208V (orange) 240V (violet) CAP LAMP (red) LAMP 277V (black) CAP (blk/wht ) CAP LAMP 347V (org/wht) CAP (blk/wht) X2 (White) CAP COM (white) COM (white) Fig. M X1 (red) 240V (violet) X2 (white) CAP (blk/wht) X3 (blue) 277V (black) LAMP LAMP IGNITOR COM (white) 347V (org/wht) X1 (red) LAMP X3 (blue) 277V (black) 120V (blk/yel) LAMP 240V (violet) X2 (white) CAP COM (white) COM (white) COM (white) LAMP1 120V (blk/yel) CAP (blk/wht) 120V (blk/yel) Fig. G 277V (black) IGNITOR 208V (orange) 208V (orange) 120V (blk/yel) X1 (red) 240V (violet) LAMP CAP (blk/wht) CAP LAMP 347V (org/wht) X3 (blue) 277V (black) CAP 480V (vio/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) Fig. V Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 07 METAL HALIDE Input Volts Cat.No. Circuit Type (V) Input Power (W) Max Ballast Input Dimensions # of Current Taps (A) A(in) B(in) Fig Net WT Wiring (lbs) Diagram Pacific Ignitor/ Starter Capacitor 1029 Class EISA (µF) VAC min H 180 N 200 250 Watt Lamp, ANSI Code M58 120/208 240/277 4MH250SAA CWA 295 4 2.6/1.5 1.3/1.2 1.6 3.5 4 8.0 F n/a 15 400 AA AA AA AA 120/208 240/277 4MH250SAA3 CWA 294 4 2.8/1.6 1.4/1.2 3.2 4.5 1 8.4 F n/a 15 400 EE EE AA AA 120/208 240/277 480 5MH/MV250SC-3 CWA 291 5 3.2/1.9 1.6/1.4 0.8 3.0 4.4 1 9.0 H n/a 15 400 CC BB A AA AA A 120/208 240/277 480 5MH250SCA CWA 289 5 2.9/1.7 1.6/1.2 0.8 1.8 3.6 4 10.2 H n/a 15 400 AA AA A AA AA A 250 Watt Lamp, ANSI Code M153, M138 (Pulse Start) 120/208 240/277 4MH250SAA-PS PS-CWA 278 4 2.5/1.4 1.3/1.1 1.9 3.8 4 9.8 E MHR3 15 400 AA AA AA AA 120/208 240/277 4MP250SAA PS-CWA 290 4 2.5/1.5 1.3/1.1 2.2 4.2 4 10.6 E MHR3 17 400 BB BA AA AA Y 120/208 240/277 4MP250SCA PS-CWA 288 4 2.7/1.6 1.4/1.2 2.2 3.9 4 11.0 E MHR3 15 400 AA AA AA AA Y 120/208 240/277 4MP250SCE PS-CWA 278 4 2.3/1.4 1.2/1.0 2.2 4.3 4 13.8 E MHR3 17 400 AA AA AA AA YY 120/208 240/277 480 5MH250SCA-PS PS-CWA 282 5 2.5/1.4 1.3/1.1 0.65 2.0 3.9 4 11.5 I MHR3 15 400 AA AA A AA AA A 120/208 240/277 480 5MP250SCA PS-CWA 288 5 2.7/1.6 1.3/1.2 0.7 2.2 4.4 4 11.5 I MHR3 15 400 AA AA A AA AA A Y YY: Exceeds EISA efficiency >90% Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig 1 Welded Foot Bracket Dimensions For Ballast Dimensions Fig 1 For Ballast Dimensions Fig 4 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch For Ballast Dimensions Fig 4 Page 08 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID BALLAST DIMENSIONS Fig. 1 Fig. 2 "B" 5.750 "A" 4.375 4.250 5.375 3.875 0.195 Min. (8X) Fig. 3 B max. Fig. 4 4.50 A 3.30 3.75 ∅0.175Min.(4X) 4.05 Fig. 5 Fig. 6 "B" 2 5/8" B max. A 4.750 "A" 4.250 1 25/32" 4 Holes >= 0.175" Cleared for #6 bolts 2 7/32" x 2 5/8" core 2 7/32" 4.375 3.875 2 3/16" Fig. 7 Fig. 8 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 09 METAL HALIDE Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps Max Input Current (A) Ballast Dimensions A(in) B(in) Fig Net WT Wiring (lbs) Diagram Pacific Ignitor/ Starter 1029 Class Capacitor EISA (µF) VAC min H 180 N 200 320 Watt Lamp, ANSI Code M132, M154, M170 (Pulse Start) 480 PS-CWA 359 2 0.8 2.2 4.2 4 11.5 L MHR3 21 345 C 120/208 4MP320SAA 240/277 PS-CWA 361 4 3.1/1.8 1.6/1.35 2.2 4.4 4 11.0 E MHR3 21 345 BB BB AA AA Y 120 3MP320SCC 277/347 PS-CWA 362 3 3/1.3 1.1 2.0 3.8 4 12.0 M MHR3 21 345 BB A A AA Y 366 5 2.2 4.3 4 11.5 I MHR3 21 345 338 1 1.3 3.0 5 5.7 N MHR3 21 345 CC CC C B AA AA A A YY 120T 2MP320SCA/T 120/208 240/277 5MP320SCA PS-CWA 480 1MP320RSCA277 R-HPF 277 3.1/1.8 1.6/1.4 0.8 2.3 Y Y 350 Watt Lamp, ANSI Code M131 (Pulse Start) 120/208 4MP350SAA 240/277 PS-CWA 390 4 3.3/1.9 1.6/1.4 2.3 4.4 4 11.4 E MHR3 24 400 BB BA AA AA Y 120/208 4MP350SCA 240/277 PS-CWA 400 4 3.3/2.0 1.8/1.5 2.3 4.4 4 11.8 E MHR3 24 400 AA AA AA AA Y 120/208 240/277 5MP350SCA 480 PS-CWA 410 5 3.4/2.0 1.7/1.5 0.9 2.3 4.4 4 12.2 I MHR3 24 330 AA AA A AA AA A Y 120/208 240/277 6MP350SCA 347/480 PS-CWA 410 6 3.4/2.0 1.7/1.5 1.3/0.9 2.3 4.4 4 12.2 O MHR3 24 330 AA AA AA AA AA AA Y YY: Exceeds EISA efficiency >90% Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig 4 For Ballast Dimensions Fig 5 Welded Foot Bracket Dimensions For Ballast Dimensions Fig 4 For Ballast Dimensions Fig 5 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 10 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID WIRING DIAGRAMS Fig. A 480V (vio/wht) LAMP (Red) CAP (blk/wht) X3 (Blue) LAMP (red) 277V (black) X1 (Red) X3 (blue) 240V (violet) 120V Aux (blk/yel) IGNITOR 208V (orange) CAP (blk/wht) 120V (blk/yel) Max 150W Incandescent Lamp COM (white) CAP 240V (violet) 208V (orange) 120V (blk/yel) X2 (white) CAP COM (White) COM (White) CAP (blk/wht) 277V (black) LAMP X2 (White) X1 (red) LAMP CAP LAMP IGNITOR COM (White) Fig. C Fig. B COM (white) COM (white) COM (white) Fig. D Fig. F Fig. E LAMP (red) 480V(vio/wht) (blk/wht) 277V (black) CAP LAMP 277V (black) 240V (violet) COM (white) 120V (blk/yel) COM (white) COM (white) Fig. I Fig. H 480V (violet/wht) X1 (red) IGN X3 (blue) LAMP1 347V (org/wht) X1 (red) IGN X3 (blue) 277V (black) X2 (white) LAMP2 (red/wht) 480V (vio/wht) X3 (blue) X1 (red) IGNITOR 120V Aux (blk/yel) LAMP2 (red/wht) 240V (violet) CAP (blk/wht) CAP (blk/wht) CAP (blk/wht) Max 250W Incandescent Lamp CAP CAP COM (white) COM (white) LAMP (red) X2 (white) X2 (white) CAP COM (white) CAP (blk/wht) CAP (blk/wht) Fig. J COM (white) Fig. L Fig. K LAMP (red) 480V (vio/wht) 347V (org/wht) LAMP (red) 277V(black) LAMP (red) X3 (blue) CAP X1 (red) IGNITO R IGNITOR 208V (orange) CAP CAP (blk/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) COM (white) Fig. O Fig. N 480V (Vio/wht) 480V (vio/wht) 277V (black) CA P 240V (violet) CA P 120V (blk/yel) 208V (orange) CAP Fig. P 277V (black) X3 (blue) Fig. S LAMP (red) 480V(vio/wht) X3 (blue) IGNITOR LAMP2 (red/wht) CAP (blk/wht) CAP (blk/wht) CAP COM (white) CAP (blk/wht) Fig. T X1 (red) CAP COM (white) COM (white) Fig. U CAP (blk/wht) CAP LAMP COM (white) 120V (blk/yel) X1 (red) IGN LAMP X2 (white) LAMP COM (white) X1 (red) IGNITO R Fig. R X2 (white) LAMP (red) X3 (blue) COM (White) COM (White) LAMP1 240V (violet) CAP (Optional) Max 400W Incandescent Lamp CAP Fig. Q 480V (violet/wht) 120V(blk/yel) CAP (Blk/wht) COM (white) COM (white) COM (white) 120V Aux (blk/yel) CAP 120V (blk/yel) COM (white) LAMP 208V (orange) 240V (violet) CAP LAMP (red) LAMP 277V (black) CAP (blk/wht ) CAP LAMP 347V (org/wht) CAP (blk/wht) X2 (White) CAP COM (white) COM (white) Fig. M X1 (red) 240V (violet) X2 (white) CAP (blk/wht) X3 (blue) 277V (black) LAMP LAMP IGNITOR COM (white) 347V (org/wht) X1 (red) LAMP X3 (blue) 277V (black) 120V (blk/yel) LAMP 240V (violet) X2 (white) CAP COM (white) COM (white) COM (white) LAMP1 120V (blk/yel) CAP (blk/wht) 120V (blk/yel) Fig. G 277V (black) IGNITOR 208V (orange) 208V (orange) 120V (blk/yel) X1 (red) 240V (violet) LAMP CAP (blk/wht) CAP LAMP 347V (org/wht) X3 (blue) 277V (black) CAP 480V (vio/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) Fig. V Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 11 METAL HALIDE Input Volts Cat.No. Circuit Type (V) Input Power (W) Max Ballast Input Dimensions # of Current Taps (A) A(in) B(in) Fig Net WT Wiring (lbs) Diagram Pacific Ignitor/ Starter Capacitor 1029 Class EISA (µF) VAC min H 180 N 200 400 Watt Lamp, ANSI Code M59 120/208 4MH400SAA 240/277 CWA 458 4 4.0/2.3 2.0/1.8 2.2 4.2 4 11.0 F n/a 24 360 BC CD AA AA 120 277/347 3MH400SCA CWA 457 3 4.0 1.8/1.4 2.3 4.2 4 12.8 G n/a 24 360 B CC A AA 120/208 240/277 5MH400SCA 480 CWA 452 5 4.0/2.3 2.0/1.81 2.3 4.3 4 11.4 H n/a 24 360 BB CC C AA AA A 120/208 240/277 6MH400SCA 347/480 CWA 435 6 4.5/2.6 2.2/1.9 1.6/1.1 2.3 4.4 4 12.5 P n/a 24 400 BB CC CC AA AA AA 400 Watt Lamp, ANSI Code M135, M155 (Pulse Start) 120/208 4MP400SAA 240/277 PS-CWA 460 4 4.0/2.3 2.0/1.8 2.4 4.2 4 11.2 E MHR3 26 400 BC DD AA AA Y 120 277/347 3MP400SCA PS-CWA 454 3 4.0 1.8/1.4 2.3 4.3 4 12.3 M MHR3 26 400 A CC A AA Y 120/208 240/277 5MP400SCA 480 PS-CWA 458 5 3.8/2.2 1.9/1.7 0.9 2.3 4.3 4 12.2 I MHR3 26 400 BB BA C AA AA A Y 120/240 3MP400MRSC83 REG LAG 277 240/277 347/480 4MP400MRSC74* REG LAG 468 3 3.7 5.6 3 23.8 J MHR3 20 440 466 4 3.9/2.0 1.7 1.2/1.7 1.4/1 3.7 5.6 3 23.8 K MHR3 20 440 AA A AA AA AA A AA AA 4.4/2.6 2.2/1.9 2.3 4.4 4 11.4 E MHR3 28 440 BB BA AA AA 450 Watt Lamp, ANSI CODE M144 (Pulse Start) 120/208 4MP450SAA 240/277 PS-CWA 520 4 Y * Add "T" to denote 120V aux. tap option for standby lighting Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig 3, 4 Welded Foot Bracket Dimensions For Ballast Dimensions Fig 3 For Ballast Dimensions Fig 4 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 12 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID BALLAST DIMENSIONS Fig. 1 Fig. 2 "B" 5.750 "A" 4.375 4.250 5.375 3.875 0.195 Min. (8X) Fig. 3 B max. Fig. 4 4.50 A 3.30 3.75 ∅0.175Min.(4X) 4.05 Fig. 5 Fig. 6 "B" 2 5/8" B max. A 4.750 "A" 4.250 1 25/32" 4 Holes >= 0.175" Cleared for #6 bolts 2 7/32" x 2 5/8" core 2 7/32" 4.375 3.875 2 3/16" Fig. 7 Fig. 8 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 13 METAL HALIDE Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps Max Input Current (A) Ballast Dimensions A(in) B(in) Fig Net WT Wiring (lbs) Diagram Pacific Ignitor/ Starter 1029 Class Capacitor EISA (µF) VAC min H 180 N 200 750 Watt Lamp, ANSI Code M149; or 775 Watt Lamp, ANSI Code M181 (Pulse Start) 120/208 4MP750SCA 240/277 PS-CWA 842 4 7.2/4.1 3.6/3.1 2.6 4.8 6 17.0 E MHR2 24 480 CB CC AA AA 120 277/347 3MP750SCA03 PS-CWA 810 3 7.2 3.1/2.5 2.8 4.8 6 18.8 M MHR2 24 480 B AA A AA 120/208 240/277 5MP750SCA 480 PS-CWA 810 5 7.2/4.1 3.6/3.1 1.8 2.8 4.8 6 18.8 I MHR2 24 480 BB AA A AA AA A 120/208 240/277 6MP750SCA 347/480 PS-CWA 810 6 7.2/4.1 3.6/3.1 2.5/1.8 2.8 4.8 6 18.8 O MHR2 24 480 BB AA AA AA AA AA 875 Watt Lamp, ANSI CODE M166 (Pulse Start)* *See 1000 Watt Lamp 1000 Watt Lamp, ANSI Code M47 120 1MH1000SAA-12 CWA 1070 1 90 3.0 5.0 6 18.7 V n/a 24 480 D A 120/208 4MH1000SCA 240/277 CWA 1076 4 9.2/5.3 4.6/4.0 3.0 4.9 6 18.9 F n/a 24 480 DC CC AA AA 120 277/347 3MH1000SCA03 CWA 1070 3 8.9/4.0 3.1 3.3 5.4 6 21.6 G n/a 24 480 DB C AA A 120/208 240/277 5MH1000SCA 480 CWA 1087 5 9.2/5.3 4.6/4.0 2.3 3.3 5.2 6 19.9 H n/a 24 480 DC CB C AA AA A 120/208 240/277 6MH1000SCA 347/480 CWA 1070 6 8.9/5.3 4.5/4.0 3.1/2.3 3.3 5.4 6 21.6 P n/a 24 480 DC CB CC AA AA AA 1000 Watt Lamp, ANSI Code M141, M47; or 875* Watt Lamp, ANSI Code M166 (Pulse Start) 120/208 4MP1000SCA 240/277 PS-CWA 1090 4 9.2/5.3 4.6/4.0 3.0 5.1 6 20.1 E HPS1K 24* 480 CB BB AA AA 120 3MP1000SCA03 277/347 PS-CWA 1075 3 8.9/4.0 3.1 3.3 5.4 6 22.0 M HPS1K 24* 480 CA B AA A 120/208 240/277 5MP1000SCA 480 PS-CWA 1070 5 8.8/5.1 4.5/3.9 2.3 3.3 5.2 6 21.4 I HPS1K 24* 480 CB BA B AA AA A 120/208 240/277 6MP1000SCA 347/480 PS-CWA 1075 6 8.9/5.3 4.5/4.0 3.1/2.3 3.3 5.4 6 22.0 O HPS1K 24* 480 CB BA BB AA AA AA 10.4/5.9 5.2/5.0 4.1 6.1 6 29.5 Q ◆ 165 280 II JJ EE FF 1000 Watt Lamp, ANSI Code CSI1000/PAR64/G38 120/208 4MH1000CSI 240/277 CWACSI 1140 4 * 875 Watt Lamp requires 22µ F, 480V capacitor ◆ Customer Supplied Ignitor Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions Welded Foot Bracket Dimensions: Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch For Ballast Dimensions Fig 6 For Ballast Dimensions Fig 6 Page 14 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID WIRING DIAGRAMS Fig. A 480V (vio/wht) LAMP (Red) CAP (blk/wht) X3 (Blue) LAMP (red) 277V (black) X1 (Red) X3 (blue) 240V (violet) 120V Aux (blk/yel) IGNITOR 208V (orange) CAP (blk/wht) 120V (blk/yel) Max 150W Incandescent Lamp COM (white) CAP 240V (violet) 208V (orange) 120V (blk/yel) X2 (white) CAP COM (White) COM (White) CAP (blk/wht) 277V (black) LAMP X2 (White) X1 (red) LAMP CAP LAMP IGNITOR COM (White) Fig. C Fig. B COM (white) COM (white) COM (white) Fig. D Fig. F Fig. E LAMP (red) 480V(vio/wht) (blk/wht) 277V (black) CAP LAMP 277V (black) 240V (violet) COM (white) 120V (blk/yel) COM (white) COM (white) Fig. I Fig. H 480V (violet/wht) X1 (red) IGN X3 (blue) LAMP1 347V (org/wht) X1 (red) IGN X3 (blue) 277V (black) X2 (white) LAMP2 (red/wht) 480V (vio/wht) X3 (blue) X1 (red) IGNITOR 120V Aux (blk/yel) LAMP2 (red/wht) 240V (violet) CAP (blk/wht) CAP (blk/wht) CAP (blk/wht) Max 250W Incandescent Lamp CAP CAP COM (white) COM (white) LAMP (red) X2 (white) X2 (white) CAP COM (white) CAP (blk/wht) CAP (blk/wht) Fig. J COM (white) Fig. L Fig. K LAMP (red) 480V (vio/wht) 347V (org/wht) LAMP (red) 277V(black) LAMP (red) X3 (blue) CAP X1 (red) IGNITO R IGNITOR 208V (orange) CAP CAP (blk/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) COM (white) Fig. O Fig. N 480V (Vio/wht) 480V (vio/wht) 277V (black) CA P 240V (violet) CA P 120V (blk/yel) 208V (orange) CAP Fig. P 277V (black) X3 (blue) Fig. S LAMP (red) 480V(vio/wht) X3 (blue) IGNITOR LAMP2 (red/wht) CAP (blk/wht) CAP (blk/wht) CAP COM (white) CAP (blk/wht) Fig. T X1 (red) CAP COM (white) COM (white) Fig. U CAP (blk/wht) CAP LAMP COM (white) 120V (blk/yel) X1 (red) IGN LAMP X2 (white) LAMP COM (white) X1 (red) IGNITO R Fig. R X2 (white) LAMP (red) X3 (blue) COM (White) COM (White) LAMP1 240V (violet) CAP (Optional) Max 400W Incandescent Lamp CAP Fig. Q 480V (violet/wht) 120V(blk/yel) CAP (Blk/wht) COM (white) COM (white) COM (white) 120V Aux (blk/yel) CAP 120V (blk/yel) COM (white) LAMP 208V (orange) 240V (violet) CAP LAMP (red) LAMP 277V (black) CAP (blk/wht ) CAP LAMP 347V (org/wht) CAP (blk/wht) X2 (White) CAP COM (white) COM (white) Fig. M X1 (red) 240V (violet) X2 (white) CAP (blk/wht) X3 (blue) 277V (black) LAMP LAMP IGNITOR COM (white) 347V (org/wht) X1 (red) LAMP X3 (blue) 277V (black) 120V (blk/yel) LAMP 240V (violet) X2 (white) CAP COM (white) COM (white) COM (white) LAMP1 120V (blk/yel) CAP (blk/wht) 120V (blk/yel) Fig. G 277V (black) IGNITOR 208V (orange) 208V (orange) 120V (blk/yel) X1 (red) 240V (violet) LAMP CAP (blk/wht) CAP LAMP 347V (org/wht) X3 (blue) 277V (black) CAP 480V (vio/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) Fig. V Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 15 METAL HALIDE Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps Max Input Current (A) Ballast Dimensions A(in) B(in) Fig Net WT Wiring (lbs) Diagram Pacific Ignitor/ Starter 1029 Class Capacitor EISA (µF) VAC min H 180 N 200 1500 Watt Lamp, ANSI Code M48 120/208 4MH1500SC 240/277 CWA 1602 4 13.5/7.7 6.6/5.9 4.1 6.3 6 30.0 F n/a 32 525 EA AA AA AA 120/208 4MH1500SCA 240/277 CWA 1550 4 13.1/7.5 6.5/5.7 4.5 6.9 6 28.1 F n/a 32 525 FE EE BA AA CWA 1623 2 3.6 4.1 5.9 6 29.0 R n/a 32 525 G C CWA 1540 6 7.5/6.5 5.7/4.5 3.3 4.7 7.2 6 30.5 P n/a 32 525 GF FE E CB BA A 480 120T 2MH1500SC/T 208/240 277/347 5MH1500SCA95* 480 120T * Add "T" to denote 120V aux. tap option for standby lighting Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions Welded Foot Bracket Dimensions For Ballast Dimensions Fig 6 For Ballast Dimensions Fig 6 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 16 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID BALLAST DIMENSIONS Fig. 1 Fig. 2 "B" 5.750 "A" 4.375 4.250 5.375 3.875 0.195 Min. (8X) Fig. 3 B max. Fig. 4 4.50 A 3.30 3.75 ∅0.175Min.(4X) 4.05 Fig. 5 Fig. 6 "B" 2 5/8" B max. A 4.750 "A" 4.250 1 25/32" 4 Holes >= 0.175" Cleared for #6 bolts 2 7/32" x 2 5/8" core 2 7/32" 4.375 3.875 2 3/16" Fig. 7 Fig. 8 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 17 HIGH PRESSURE SODIUM Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps 54 1 61 Max Input Current Ballast Dimensions Net WT (lbs) Wiring Diagram Pacific Ignitor/ Starter 1029 Class Capacitor (µF) VAC min H 180 N 200 HPSR1 n/a n/a A A HPSR1 n/a n/a A A 5 280 AA AA AA AA n/a n/a A A 7 280 BB BB 7 300 A (A) A(in) B(in) Fig 1.0 0.6 1.8 7 1.1 S 1 1.0 0.8 2.0 7 1.7 S 68 4 1.0/0.6 0.5/0.4 1.0 2.5 1 3.5 A HPSR1 83 1 1.7 1.3 2.5 7 2.0 S HPSR1 1.5 3.0 1 4.6 A HPSR1 1.9 3.2 1 5.8 B HPSR1 35 Watt Lamp, ANSI Code S76 120 1HPS35SC120 R-NPF 50 Watt Lamp, ANSI Code S68 120 120/208 240/277 1HPS50SC120 4HPS50HXSCA R-NPF HX-HPF 70 Watt Lamp, ANSI Code S62 120 1HPS70SC120 R-NPF 120/208 240/277 4HPS70HXSCA HX-HPF 95 4 1.4/0.8 0.7/0.6 480 2HPS70HXSC/T HX-HPF 95 2 0.4 120T Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig. 1 For Ballast Dimensions Fig. 7 Welded Foot Bracket Dimensions For Ballast Dimensions Fig. 1 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 18 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. A HID WIRING DIAGRAMS Fig. A 480V (vio/wht) LAMP (Red) CAP (blk/wht) X3 (Blue) LAMP (red) 277V (black) X1 (Red) X3 (blue) 240V (violet) 120V Aux (blk/yel) IGNITOR 208V (orange) CAP (blk/wht) 120V (blk/yel) Max 150W Incandescent Lamp COM (white) CAP 240V (violet) 208V (orange) 120V (blk/yel) X2 (white) CAP COM (White) COM (White) CAP (blk/wht) 277V (black) LAMP X2 (White) X1 (red) LAMP CAP LAMP IGNITOR COM (White) Fig. C Fig. B COM (white) COM (white) COM (white) Fig. D Fig. F Fig. E LAMP (red) 480V(vio/wht) (blk/wht) 277V (black) CAP LAMP 277V (black) 240V (violet) COM (white) 120V (blk/yel) COM (white) COM (white) Fig. I Fig. H 480V (violet/wht) X1 (red) IGN X3 (blue) LAMP1 347V (org/wht) X1 (red) IGN X3 (blue) 277V (black) X2 (white) LAMP2 (red/wht) 480V (vio/wht) X3 (blue) X1 (red) IGNITOR 120V Aux (blk/yel) LAMP2 (red/wht) 240V (violet) CAP (blk/wht) CAP (blk/wht) CAP (blk/wht) Max 250W Incandescent Lamp CAP CAP COM (white) COM (white) LAMP (red) X2 (white) X2 (white) CAP COM (white) CAP (blk/wht) CAP (blk/wht) Fig. J COM (white) Fig. L Fig. K LAMP (red) 480V (vio/wht) 347V (org/wht) LAMP (red) 277V(black) LAMP (red) X3 (blue) CAP X1 (red) IGNITO R IGNITOR 208V (orange) CAP CAP (blk/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) COM (white) Fig. O Fig. N 480V (Vio/wht) 480V (vio/wht) 277V (black) CA P 240V (violet) CA P 120V (blk/yel) 208V (orange) CAP Fig. P 277V (black) X3 (blue) Fig. S LAMP (red) 480V(vio/wht) X3 (blue) IGNITOR LAMP2 (red/wht) CAP (blk/wht) CAP (blk/wht) CAP COM (white) CAP (blk/wht) Fig. T X1 (red) CAP COM (white) COM (white) Fig. U CAP (blk/wht) CAP LAMP COM (white) 120V (blk/yel) X1 (red) IGN LAMP X2 (white) LAMP COM (white) X1 (red) IGNITO R Fig. R X2 (white) LAMP (red) X3 (blue) COM (White) COM (White) LAMP1 240V (violet) CAP (Optional) Max 400W Incandescent Lamp CAP Fig. Q 480V (violet/wht) 120V(blk/yel) CAP (Blk/wht) COM (white) COM (white) COM (white) 120V Aux (blk/yel) CAP 120V (blk/yel) COM (white) LAMP 208V (orange) 240V (violet) CAP LAMP (red) LAMP 277V (black) CAP (blk/wht ) CAP LAMP 347V (org/wht) CAP (blk/wht) X2 (White) CAP COM (white) COM (white) Fig. M X1 (red) 240V (violet) X2 (white) CAP (blk/wht) X3 (blue) 277V (black) LAMP LAMP IGNITOR COM (white) 347V (org/wht) X1 (red) LAMP X3 (blue) 277V (black) 120V (blk/yel) LAMP 240V (violet) X2 (white) CAP COM (white) COM (white) COM (white) LAMP1 120V (blk/yel) CAP (blk/wht) 120V (blk/yel) Fig. G 277V (black) IGNITOR 208V (orange) 208V (orange) 120V (blk/yel) X1 (red) 240V (violet) LAMP CAP (blk/wht) CAP LAMP 347V (org/wht) X3 (blue) 277V (black) CAP 480V (vio/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) Fig. V Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 19 HIGH PRESSURE SODIUM Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps 116 1 Max Input Current Ballast Dimensions (A) A(in) B(in) Fig 2.1 1.8 3.0 7 Net WT (lbs) Wiring Diagram 2.5 S Pacific Ignitor/ Starter 1029 Class Capacitor (µF) VAC min H 180 n/a n/a A N 200 100 Watt Lamp, ANSI Code S54 1HPS100SCA120 120 R-NPF HPSR1 120/208 240/277 4HPS100HXSCA HX-HPF 130 4 2.2/1.3 1.1/1.0 2.0 3.4 1 6.0 A HPSR1 10 280 BB BB 480 2HPS100HXSC/T HX-HPF 132 2 0.6 2.0 3.4 1 6.2 C HPSR1 10 280 C 4HPS100MRSC84 REG LAG 137 4 1.1/0.6 0.5/0.3 1.3 3.1 8 8.5 T HPSR1 16 280 A AA AA 120T 120/240 277/480 A AA AA 150 Watt Lamp, ANSI Code S55 120 1HPS150SCA120 R-NPF 168 1 3.1 2.4 3.5 7 3.3 S HPSR1 n/a n/a C 120/208 240/277 4HPS150HXSCA HX-HPF 182 4 3.0/1.7 1.5/1.3 2.6 4.1 1 7.4 A HPSR1 14 280 DC BB 480 2HPS150HXSC/T HX-HPF 188 2 0.8 3.0 4.3 1 8.6 D HPSR1 14 280 F B 4HPS150MRSC84 REG LAG 186 4 2.0/1.0 0.9/0.5 2.0 3.5 8 11.6 T HPSR1 16 300 A AA A A AA A 120T 120/240 277/480 Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig 1 For Ballast Dimensions Fig 8 For Ballast Dimensions Fig 7 Welded Foot Bracket Dimensions For Ballast Dimensions Fig 1 For Ballast Dimensions Fig 8 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 20 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID BALLAST DIMENSIONS Fig. 1 Fig. 2 "B" 5.750 "A" 4.375 4.250 5.375 3.875 0.195 Min. (8X) Fig. 3 B max. Fig. 4 4.50 A 3.30 3.75 ∅0.175Min.(4X) 4.05 Fig. 5 Fig. 6 "B" 2 5/8" B max. A 4.750 "A" 4.250 1 25/32" 4 Holes >= 0.175" Cleared for #6 bolts 2 7/32" x 2 5/8" core 2 7/32" 4.375 3.875 2 3/16" Fig. 7 Fig. 8 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 21 HIGH PRESSURE SODIUM Input Volts Cat.No. Input Power (W) # of Taps CWA 240 Circuit Type (V) Max Input Current Ballast Dimensions Net WT (lbs) Wiring Diagram (A) A(in) B(in) Fig 4 2.1/1.2 1.1/0.9 1.2 3.1 4 7.6 E Pacific Ignitor/ Starter Capacitor 1029 Class (µF) VAC min H 180 N 200 HPS24 28 250 AA AA AA AA 200 Watt Lamp, ANSI Code S66 120/208 240/277 4HPS200SAC 120/240 277 3HPS200MRSC83 REG LAG 252 3 2.6/1.3 1.17 2.3 4.3 8 13.3 J HPS24 18 350 CB B AA A 240/277 347/480 4HPS200MRSC74 REG LAG 252 4 1.3/1.1 0.9/0.6 2.3 4.3 8 13.3 K HPS24 18 350 BB BA AA AA 2.5/1.5 1.3/1.1 1.9 3.5 4 9.9 E HPS24 35 240 CC BB AA AA 2.0 3.9 4 10.7 I HPS24 35 240 2.0 3.9 4 10.7 O HPS24 35 240 DD CC C DD CC CC AA AA A AA AA AA 250 Watt Lamp, ANSI Code S50 120/208 240/277 4HPS250SCA CWA 300 4 5HPS250SCA CWA 298 5 6HPS250SCA CWA 298 6 120/277 347 3HPS250SCA03 CWA 298 3 2.6/1.1 0.9 2.0 3.9 4 10.7 M HPS24 35 240 DC C AA A 120/240 277 3HPS250MRSC83 REG LAG 308 3 2.7/1.3 1.2 2.4 4.2 3 16.5 J HPS24 16 400 AA A AA A 240/277 347/480 4HPS250MRSC74 REG LAG 304 4 1.3/1.2 0.9/0.7 2.4 4.2 3 16.5 K HPS24 16 400 AA AA AA AA 120/208 240/277 480 120/208 240/277 347/480 2.6/1.5 1.3/1.1 0.6 2.6/1.5 1.3/1.1 0.9/0.6 Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions Welded Foot Bracket Dimensions For Ballast Dimension Fig. 3 For Ballast Dimensions Fig 3, 4, 8 For Ballast Dimension Fig. 4,8 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 22 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID WIRING DIAGRAMS Fig. A 480V (vio/wht) LAMP (Red) CAP (blk/wht) X3 (Blue) LAMP (red) 277V (black) X1 (Red) X3 (blue) 240V (violet) 120V Aux (blk/yel) IGNITOR 208V (orange) CAP (blk/wht) 120V (blk/yel) Max 150W Incandescent Lamp COM (white) CAP 240V (violet) 208V (orange) 120V (blk/yel) X2 (white) CAP COM (White) COM (White) CAP (blk/wht) 277V (black) LAMP X2 (White) X1 (red) LAMP CAP LAMP IGNITOR COM (White) Fig. C Fig. B COM (white) COM (white) COM (white) Fig. D Fig. F Fig. E LAMP (red) 480V(vio/wht) (blk/wht) 277V (black) CAP LAMP 277V (black) 240V (violet) COM (white) 120V (blk/yel) COM (white) COM (white) Fig. I Fig. H 480V (violet/wht) X1 (red) IGN X3 (blue) LAMP1 347V (org/wht) X1 (red) IGN X3 (blue) 277V (black) X2 (white) LAMP2 (red/wht) 480V (vio/wht) X3 (blue) X1 (red) IGNITOR 120V Aux (blk/yel) LAMP2 (red/wht) 240V (violet) CAP (blk/wht) CAP (blk/wht) CAP (blk/wht) Max 250W Incandescent Lamp CAP CAP COM (white) COM (white) LAMP (red) X2 (white) X2 (white) CAP COM (white) CAP (blk/wht) CAP (blk/wht) Fig. J COM (white) Fig. L Fig. K LAMP (red) 480V (vio/wht) 347V (org/wht) LAMP (red) 277V(black) LAMP (red) X3 (blue) CAP X1 (red) IGNITO R IGNITOR 208V (orange) CAP CAP (blk/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) COM (white) Fig. O Fig. N 480V (Vio/wht) 480V (vio/wht) 277V (black) CA P 240V (violet) CA P 120V (blk/yel) 208V (orange) CAP Fig. P 277V (black) X3 (blue) Fig. S LAMP (red) 480V(vio/wht) X3 (blue) IGNITOR LAMP2 (red/wht) CAP (blk/wht) CAP (blk/wht) CAP COM (white) CAP (blk/wht) Fig. T X1 (red) CAP COM (white) COM (white) Fig. U CAP (blk/wht) CAP LAMP COM (white) 120V (blk/yel) X1 (red) IGN LAMP X2 (white) LAMP COM (white) X1 (red) IGNITO R Fig. R X2 (white) LAMP (red) X3 (blue) COM (White) COM (White) LAMP1 240V (violet) CAP (Optional) Max 400W Incandescent Lamp CAP Fig. Q 480V (violet/wht) 120V(blk/yel) CAP (Blk/wht) COM (white) COM (white) COM (white) 120V Aux (blk/yel) CAP 120V (blk/yel) COM (white) LAMP 208V (orange) 240V (violet) CAP LAMP (red) LAMP 277V (black) CAP (blk/wht ) CAP LAMP 347V (org/wht) CAP (blk/wht) X2 (White) CAP COM (white) COM (white) Fig. M X1 (red) 240V (violet) X2 (white) CAP (blk/wht) X3 (blue) 277V (black) LAMP LAMP IGNITOR COM (white) 347V (org/wht) X1 (red) LAMP X3 (blue) 277V (black) 120V (blk/yel) LAMP 240V (violet) X2 (white) CAP COM (white) COM (white) COM (white) LAMP1 120V (blk/yel) CAP (blk/wht) 120V (blk/yel) Fig. G 277V (black) IGNITOR 208V (orange) 208V (orange) 120V (blk/yel) X1 (red) 240V (violet) LAMP CAP (blk/wht) CAP LAMP 347V (org/wht) X3 (blue) 277V (black) CAP 480V (vio/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) Fig. V Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 23 HIGH PRESSURE SODIUM Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps Max Input Current Ballast Dimensions (A) A(in) B(in) Fig Net WT (lbs) Wiring Diagram Pacific Ignitor/ Starter Capacitor 1029 Class (µF) VAC min H 180 N 200 310 Watt Lamp, ANSI Code S67 120 240/277 3HPS310MRSC83 REG LAG 370 3 3.2 1.6/1.5 2.8 4.8 3 19.8 J HPS24 17 460 B AA A AA 240/277 347/480 4HPS310MRSC74 REG LAG 372 4 1.6/1.4 1.1/0.8 2.8 4.8 3 20.0 K HPS24 17 460 AA AA AA AA 400 Watt Lamp, ANSI Code S51 120/208 240/277 4HPS400SCA CWA 453 4 3.8/2.2 1.9/1.7 2.3 4.2 4 12.4 E HPS24 55 240 DD DD AA AA 120/208 240/277 4HPS400SAC CWA 455 4 3.9/2.3 2/1.7 2.3 4.2 4 13.1 E HPS24 55 240 DD DC AA AA 120/277 347 3HPS400SAC03 CWA 462 3 3.9/1.7 1.4 2.3 4.3 4 13.0 M HPS24 55 240 ED C AA A 480 120/208 240/277 480 120/208 240/277 480 120/208 240/277 347/480 120/208 240/277 347/480 120/240 277 240/277 347/480 1HPS400SCA48T CWA 450 1 2.6 4.7 4 13.5 L HPS24 55 240 5HPS400SCA CWA 450 5 2.6 4.7 4 13.5 I HPS24 55 240 5HPS400SAC CWA 462 5 2.3 4.3 4 13.0 I HPS24 55 240 6HPS400SCA CWA 450 5 2.6 4.7 4 13.5 O HPS24 55 240 6HPS400SAC CWA 400 6 2.3 4.3 4 13.0 O HPS24 55 240 3HPS400MRSC83 REG LAG 481 3 3.5 5.4 3 24.2 J HPS24 24 430 4HPS400MRSC74 REG LAG 481 4 0.9 3.8/2.2 1.9/1.6 0.9 3.9/2.3 2.0/1.7 1.0 3.8/2.2 1.9/1.6 1.3/0.9 3.9/2.3 2.0/1.7 1.4/1.0 4.3/2.1 1.8 2.2/1.9 1.5/1.1 3.5 5.4 3 24.6 K HPS24 24 430 D EE ED D EE DD C EE ED DD EE DD CC CB B AA AA A A AA AA A AA AA AA AA AA AA AA AA AA A AA AA Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions Welded Foot Bracket Dimensions For Ballast Dimensions Fig 3 For Ballast Dimensions Fig 3, 4 For Ballast Dimensions Fig 4 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 24 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID BALLAST DIMENSIONS Fig. 1 Fig. 2 "B" 5.750 "A" 4.375 4.250 5.375 3.875 0.195 Min. (8X) Fig. 3 B max. Fig. 4 4.50 A 3.30 3.75 ∅0.175Min.(4X) 4.05 Fig. 5 Fig. 6 "B" 2 5/8" B max. A 4.750 "A" 4.250 1 25/32" 4 Holes >= 0.175" Cleared for #6 bolts 2 7/32" x 2 5/8" core 2 7/32" 4.375 3.875 2 3/16" Fig. 7 Fig. 8 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 25 HIGH PRESSURE SODIUM Input Volts Cat.No. Circuit Type (V) Input Power (W) # of Taps Max Input Current Ballast Dimensions (A) A(in) B(in) Fig Net WT (lbs) Wiring Diagram Pacific Ignitor/ Starter 1029 Class Capacitor (µF) VAC min H 180 N 200 1000 Watt Lamp, ANSI Code S52 120/208 240/277 4HPS1000SAA CWA 1060 4 8.8/5.1 4.4/3.9 4.3 6.3 6 26.0 E HPS1K 26 525 EE EE AA AA 120/208 240/277 4HPS1000SC CWA 1150 4 9/5.2 4.5/4.0 3.7 6.1 6 28.0 E HPS1K 26 525 AA AA AA AA 120/277 347 120/208 240/277 480 120/208 240/277 347/480 3HPS1000SCA03 CWA 1130 3 4.1 6.2 6 26.3 M HPS1K 26 525 5HPS1000SCA CWA 1070 5 4.1 6.1 6 26.0 I HPS1K 26 525 6HPS1000SCA CWA 1130 5 9.7/4.2 3.3 9.7/5.6 4.9/4.2 2.4 9.7/5.6 4.9/4.2 3.3/2.4 4.1 6.2 6 26.3 O HPS1K 26 525 ED D ED DD C ED DD DC AA A AA AA A AA AA AA Ordering Information (Add suffix for options) - WB With welded foot bracket - I With ignitor - DC With dry film capacitor, subject to availability - OC With oil filled capacitor, subject to availability - K Distributor replacement kit (includes bracket, capacitor and ignitor as necessary.) Contact Manufacturer’s rep for specialty bracket/accessory availability Kit Bracket Dimensions For Ballast Dimensions Fig 6 Welded Foot Bracket Dimensions For Ballast Dimensions Fig 6 Note: Bracket Dimensions in millimeters, where 1milimeter = 1/25.4 inch Page 26 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID WIRING DIAGRAMS Fig. A 480V (vio/wht) LAMP (Red) CAP (blk/wht) X3 (Blue) LAMP (red) 277V (black) X1 (Red) X3 (blue) 240V (violet) 120V Aux (blk/yel) IGNITOR 208V (orange) CAP (blk/wht) 120V (blk/yel) Max 150W Incandescent Lamp COM (white) CAP 240V (violet) 208V (orange) 120V (blk/yel) X2 (white) CAP COM (White) COM (White) CAP (blk/wht) 277V (black) LAMP X2 (White) X1 (red) LAMP CAP LAMP IGNITOR COM (White) Fig. C Fig. B COM (white) COM (white) COM (white) Fig. D Fig. F Fig. E LAMP (red) 480V(vio/wht) (blk/wht) 277V (black) CAP LAMP 277V (black) 240V (violet) COM (white) 120V (blk/yel) COM (white) COM (white) Fig. I Fig. H 480V (violet/wht) X1 (red) IGN X3 (blue) LAMP1 347V (org/wht) X1 (red) IGN X3 (blue) 277V (black) X2 (white) LAMP2 (red/wht) 480V (vio/wht) X3 (blue) X1 (red) IGNITOR 120V Aux (blk/yel) LAMP2 (red/wht) 240V (violet) CAP (blk/wht) CAP (blk/wht) CAP (blk/wht) Max 250W Incandescent Lamp CAP CAP COM (white) COM (white) LAMP (red) X2 (white) X2 (white) CAP COM (white) CAP (blk/wht) CAP (blk/wht) Fig. J COM (white) Fig. L Fig. K LAMP (red) 480V (vio/wht) 347V (org/wht) LAMP (red) 277V(black) LAMP (red) X3 (blue) CAP X1 (red) IGNITO R IGNITOR 208V (orange) CAP CAP (blk/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) COM (white) Fig. O Fig. N 480V (Vio/wht) 480V (vio/wht) 277V (black) CA P 240V (violet) CA P 120V (blk/yel) 208V (orange) CAP Fig. P 277V (black) X3 (blue) Fig. S LAMP (red) 480V(vio/wht) X3 (blue) IGNITOR LAMP2 (red/wht) CAP (blk/wht) CAP (blk/wht) CAP COM (white) CAP (blk/wht) Fig. T X1 (red) CAP COM (white) COM (white) Fig. U CAP (blk/wht) CAP LAMP COM (white) 120V (blk/yel) X1 (red) IGN LAMP X2 (white) LAMP COM (white) X1 (red) IGNITO R Fig. R X2 (white) LAMP (red) X3 (blue) COM (White) COM (White) LAMP1 240V (violet) CAP (Optional) Max 400W Incandescent Lamp CAP Fig. Q 480V (violet/wht) 120V(blk/yel) CAP (Blk/wht) COM (white) COM (white) COM (white) 120V Aux (blk/yel) CAP 120V (blk/yel) COM (white) LAMP 208V (orange) 240V (violet) CAP LAMP (red) LAMP 277V (black) CAP (blk/wht ) CAP LAMP 347V (org/wht) CAP (blk/wht) X2 (White) CAP COM (white) COM (white) Fig. M X1 (red) 240V (violet) X2 (white) CAP (blk/wht) X3 (blue) 277V (black) LAMP LAMP IGNITOR COM (white) 347V (org/wht) X1 (red) LAMP X3 (blue) 277V (black) 120V (blk/yel) LAMP 240V (violet) X2 (white) CAP COM (white) COM (white) COM (white) LAMP1 120V (blk/yel) CAP (blk/wht) 120V (blk/yel) Fig. G 277V (black) IGNITOR 208V (orange) 208V (orange) 120V (blk/yel) X1 (red) 240V (violet) LAMP CAP (blk/wht) CAP LAMP 347V (org/wht) X3 (blue) 277V (black) CAP 480V (vio/wht) 120V (blk/yel) X2 (white) COM (white) COM (white) Fig. V Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 27 IGNITOR / STARTER Lamp Compatibility Cat. No. Pulse Voltage (kV)* Pulse Width (µS)** Dimensions Net WT Ballast To Lamp Distance Max Case Temp. A (in) B (in) C (in) Ф or D (in) Fig (lbs) (ft) (°C) Ignitor for Metal Halide Lamps 50-150W MHR1 3~4 ≥1 2.6 14 n/a 1.3 9 0.3 25 105 175-450W MHR3 3~4 ≥1 2.6 14 n/a 1.3 9 0.3 10 105 750W MHR2 3~4 ≥1.5 2.9 14 2 1.3 10 0.5 15 105 1000W HPS1K 3~5 ≥4 2.4 2.9 14 40 11 0.5 15 105 Ignitor for Metal Halide Lamps 35-150W HPSR1 2.5~4 ≥1 2.6 14 n/a 33 9 0.3 10 105 200-400W HPS24 2.5~4 ≥1 2.6 14 n/a 33 9 0.3 10 105 1000W HPS1K 3~5 ≥4 2.4 2.9 14 40 11 0.5 15 105 Net WT Ballast To Lamp Distance Max Case Temp. * With a dummy lamp load of 20pF ** At 2250 volts for HPSR1 and HPS24; 2700 volts for MHR1, MHR3, MHR2 and HPS1K Lamp Compatibility Cat. No. Pulse Voltage (kV)* Pulse Width (µS)** Dimensions A (in) B (in) C (in) Ф or D (in) Fig (lbs) (ft) (°C) 2.9 14 2 1.3 10 0.5 25 105 Auto Shut Off Ignitor for Metal Halide Lamps 35-400W MHR1-AS 3.0~4.0 ≥1 Auto Shut Off Ignitor for High Pressure Sodium Lamps 35-150W HPSR1-AS 2.5~4.0 ≥1 2.9 14 2 1.3 10 0.5 10 105 200-400W HPS24-AS 2.5~4.0 ≥1 2.9 14 2 1.3 10 0.5 10 105 3.0~4.0 ≥3 2.9 14 2 1.3 10 0.5 50 105 Long Range Ignitor 175W-750W MHR4-LR * With a dummy lamp load of 20pF ** At 2250 volts for HPSR1-AS and HPS24-AS; 2700 volts for MHR1-AS, MHR4-LR Page 28 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID IGNITOR/STARTER Fig. 9 Fig. 10 Fig. 11 CAPACITOR/IGNITOR BRACKET DIMENSIONS Note: Ignitor Dimensions in millimeters, where 1milimeter = 1/25.4 inch Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 29 METAL HALIDE - F.CAN Input Volts Cat. No. Circuit Type (V) Input Power (W) # of Taps Max Input Current Net WT Case Dimensions 1029 Class Wiring Diagram Ignitor/Capacitor (A) L (in) W (in) H (in) M (in) Fig (lbs) 2 1.3/0.5 11.8 3.2 2.7 11.1 12 8.3 W N/A (Integral) AA A 105 50 Watt Lamp, ANSI Code M110, M148 120/277 FP50HXSAA92 HX-HPF 64 70 Watt Lamp, ANSI Code M98, M143 120/277 FP70HXSCA92 HX-HPF 85 2 1.7/0.7 11.8 3.2 2.7 11.1 12 9.2 W N/A (Integral) AA 120/347 FP70HXSCA52C HX-HPF 85 2 1.7/0.6 11.8 3.2 2.7 11.1 12 9.5 X N/A (Integral) AA 100 Watt Lamp, ANSI Code M90, M140 120/277 FP100HXSCA92 HX-HPF 121 2 2.5/1.1 11.8 3.2 2.7 11.1 12 9.4 W N/A (Integral) AA 120/347 FP100HXSCA52C HX-HPF 120 2 2.5/0.9 11.8 3.2 2.7 11.1 12 9.3 X N/A (Integral) AA 150 Watt Lamp, ANSI Code M102, M142 120/277 FP150HXSCA92 HX-HPF 170 2 3.4/1.5 11.8 3.2 2.7 11.1 12 10.1 W N/A (Integral) AA 120/347 FP150HXSCA52C HX-HPF 176 2 3.4/1.2 11.8 3.2 2.7 11.1 12 10.2 X N/A (Integral) AA 175 Watt Lamp, ANSI Code M57 120/277 FM175SC92 CWA 200 2 2.5/1.1 11.8 3.2 2.7 11.1 12 11.8 W N/A (Integral) AA 120/347 FM175SC52C CWA 200 2 2.5/0.9 11.8 3.2 2.7 11.1 12 11.6 X N/A (Integral) AA 250 Watt Lamp, ANSI Code M58 120/277 FM250SC92 CWA 290 2 3.1/1.4 14.3 3.2 2.6 11.1 12 14.0 W N/A (Integral) AA 120/347 FM250SC52C CWA 295 2 3.4/1.2 14.3 3.2 2.6 11.1 12 14.1 X N/A (Integral) AA 400 Watt Lamp, ANSI Code M59 120/277 FM400SC92 CWA 460 2 5.1/2.2 19.2 3.2 2.4 18.6 12 19.6 W N/A (Integral) AA 120/347 FM400SC52C CWA 460 2 5.2/1.9 19.2 3.2 2.4 18.6 12 19.8 X N/A (Integral) AA CASE DIMENSIONS WIRING DIAGRAMS Fig. W Fig. 12 Fig. X Page 30 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. HID HIGH PRESSURE SODIUM - FCAN Input Volts Circuit Type Cat. No. (V) Input Power (W) # of Taps 66 2 Max Input Current Net WT Case Dimensions 1029 Class Wiring Diagram Ignitor/Capacitor (A) L (in) W (in) H (in) M (in) Fig (lbs) 1.0/0.5 11.8 3.2 2.7 11.1 12 8.7 W N/A (Integral) AA A 105 50 Watt Lamp, ANSI Code S68 120/277 FS50HXSCA92 HX-HPF 70 Watt Lamp, ANSI Code S62 ‘ 120/277 FS70HXSCA92 HX-HPF 91 2 1.4/0.64 11.8 3.2 2.7 11.1 12 9.4 W N/A (Integral) AA 120/347 FS70HXSCA52C HX-HPF 91 2 1.5/0.5 11.8 3.2 2.7 11.1 12 9.7 X N/A (Integral) AA 100 Watt Lamp, ANSI Code S54 120/277 FS100HXSCA92 HX-HPF 123 2 1.9/0.9 11.8 3.2 2.7 11.1 12 9.7 W N/A (Integral) AA 120/347 FS100HXSCA52C HX-HPF 123 2 1.9/0.7 11.8 3.2 2.7 11.1 12 9.7 X N/A (Integral) AA 150 Watt Lamp, ANSI Code S55 120/277 FS150HXSCA92 HX-HPF 173 2 2.6/1.2 11.8 3.2 2.7 11.1 12 11.0 W N/A (Integral) AA 120/347 FS150HXSCA52C HX-HPF 170 2 2.6/1 11.8 3.2 2.7 11.1 12 11.0 X N/A (Integral) AA CASE DIMENSIONS WIRING DIAGRAMS Fig. W Fig. 12 Fig. X Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Page 31 STEPDOWN AUTOTRANSFORMERS-SLIMLINE Volts Input (V) Max. Input Current (A) Volts Output (V) MTM00503424C 347 0.2 MTM00504824C 480 - 347 0.2 480 0.1 Max Load ( V.A. ) Cat. No. 50 50 Case Dimensions Full Load Net WT (lbs) Wiring Diagram Eff. (%) THD (%) Power Factor A (in) B (in) Fig 240 95 11.6 0.98 2.1 1.2 13 0.7 A1 240 92 11.6 0.98 - - 13 - A2 94 12.1 0.98 92 11.6 0.98 3.0 2.1 13 1.2 A3 50 MTM00506224C 100 MTM01003424C 347 0.3 240 96 12.1 0.99 3.2 2.4 13 1.3 A1 MTM01004824C 480 - 240 93 11.7 0.99 - - 13 - A2 347 0.3 95 12.1 0.99 480 0.2 93 11.7 0.99 4.0 3.1 13 1.7 A3 100 100 MTM01006224C 240 240 215 MTM02153424C 347 - 240 93 15.0 0.98 - - 13 - A1 215 MTM02154824C 480 - 240 91 15.0 0.98 - - 13 - A2 347 0.7 93 15.0 0.98 480 0.5 91 15.0 0.98 5.6 4.7 13 2.5 A3 215 MTM02156224C 240 *Contact Manufacturer for Additonal Information CASE DIMENSIONS B MAX Pacific Ballast Stepdown Autotransformers Model Nunbers 1.62" A 1.31" MTM 0050 62 24C Ⅰ Ⅱ Ⅲ Ⅳ MTM= Magnetic Autotransformers Max V.A.Load 50-215 Input Volt Tap Code= 34(347) 48(480) 62(347,480) Fig. 13 WIRING DIAGRAMS Fig. A1 Page 32 Fig. A2 Fig. A3 Pacific HID ballast line comprises over 350 unique models - Contact McWong for additional items not listed above. Ouput Volt Tap Code= 24(240) 12(120)Pending Note McWong International, Inc 1921 Arena Blvd Sacramento, California 95834 USA Tel: 916-371-8080 Fax: 916-371-6666 www.McWonginc.com