FLOODLIGHTING ACP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154 UltraFlood™ Series 75 . . . . . . . . . . . . . . . . . . . .156 UltraFlood™ Series 77 . . . . . . . . . . . . . . . . . . . . .158 Energy Saver Series CES . . . . . . . . . . . . . . . . . .160 Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . .162 Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . .163 AmeriSport™ Series ASP . . . . . . . . . . . . . . . . .164 Sportslighting Series SPF . . . . . . . . . . . . . . . . .166 Options & Accessories . . . . . . . . . . . . . . . . . . . .168 Ballast Matrices . . . . . . . . . . . . . . . . . . . . . .173-174 American Electric Lighting® 153 ACP Series American Compact Floodlight 70-400W HPS; 175-400W MH P R O D U C T O V E R V I E W NEW Features: NEMA beam patterns available in a variety of options Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Door is hinged and easily removable for quick maintenance Fully pivoting painted wraparound yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming UL listing is standard @ 40º ambient For easy maintenance, tool-less entry is available Standardized hardware for single-tool internal maintenance Suitable for -40°C to 40°C HPS / -30ºC to 40ºC MH Lens is thermal shock and impact resistant tempered flat glass Approved for use in 1.5 G vibration applications Applications: Auto dealerships Schools Construction sites Recreational areas Churches Industrial sites Shopping centers Parking lots Substations Building facades DIMENSIONS All electrical components warranted by American Electric Lighting's 6-year guarantee PREFERRED SELECTION CATALOG NUMBERS ACP 15S RN 120 76 EC NL TL ACP 23S CA MT1 76 EC 0643 TL NL ACP 40M SC MT7 76 TM TL ACP 40M SC MT1 76 LC 0443 TL PC ACP 40M SC MT1 76 0443 TL NL ACP 40S CA MT1 76 EC LC 0443 TL PC Effective Projected Area (EPA) The EPA for the ACP Series is 1.60 sq. ft. Approx. Wt. = 35 lbs. 154 Product Guide For photometric information, visit our website, www.americanelectriclighting.com ACP Series American Compact Floodlight 70-400W HPS; 175-400W MH O R D E R I N G I N F O R M AT I O N Example: A C P 4 0 M C A M T 1 7 6 0 4 4 3 L C T L P C Series ACP American Compact Flood Wattage / Source 07 10 15 17 20 25 31 40 23 70W 100W 150W 175W1 200W2 250W 310W2 400W 250/400W Wired 250W3 24 250/400W Wired 400W2, 3 S HPS M MH Voltage Ballast RN Reactor Normal Power Factor4 RH Reactor High Power Factor4 XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA (Auto Reg) CT CWI 120 208 240 277 347 480 MT1 MT2 MT7 TT3 5T4 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V 5-tap Wired 480V NEMA Beam Pattern 55 66 76 5H x 5V1 6H x 6V 7H x 6V Refer to the ballast matrix on page 173 for compatibility. Options Lamp Mounting5 LC Lamp Included, Clear (blank) Wraparound Yoke Mount (standard)1 LD Lamp Included, Deluxe YG Wraparound Yoke Galvanized TM Tenon Slipfitter Fusing7 SF Single Fuse (120, 277, 347V) Paint6 DF Double Fuse (208, 220, 240, 480V) (blank) Bronze (standard) BK Black Cord Type* Cord Length* GY Gray 04 4’ 63 16-3 WH White 05 5’ 44 14-48 06 6’ 43 14-3 Terminal Block 08 8’ 23 12-3 (blank) Terminal Block Factory Wire 10 10’ T2 Wired to L1 and L2 Position *Cord length and type 12 12’ T3 3 Wire Operation should be combined to 15 15’ (L1, N, L2 Position) form one number. 20 20’ Ex: 0423 25 25’ Listing 30 30’ (blank) UL Listed (standard) CS CSA Certified Misc. XL No Listing TL Tool-less Entry PC Photocontrol Included per Photocontrol Receptacle Voltage Specified (blank) Photocontrol Receptacle (standard) 5H 50 Hertz Ballast Frequency9 NR No PEC Receptacle NL NEMA Label Starter2 (blank) Open Board (standard) OP Open Board Plug-in EC Encapsulated Plug-in Notes: 1 MH only 2 HPS only 3 Available in CA ballast option only 4 Available in 120V for 50-150W HPS, 220 to 240V only available for 200-400W HPS; not available in MH 5 Painted to match fixture 6 Other colors available, please contact your local American Electric Lighting representative 7 Not available in multi-tap ballast options 8 For 3-wire operation and ground 9 Limited availability, please contact your local American Electric Lighting representative Product Guide 155 UltraFlood™ Series 75 Heavy Duty Floodlight 100-400W HPS; 175-400W MH P R O D U C T O V E R V I E W Features: NEMA beam patterns available in a variety of options including horizontal and vertical lamps Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Door is hinged and easily removable for quick maintenance Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming UL listing is standard For easy of maintenance, tool-less entry and ballast tray are available options Lens is thermal shock and impact resistant tempered glass Hydroformed reflector Suitable for -30°C MH / -40°C HPS Applications: Auto dealerships Schools Construction sites Recreational areas Storage yards Office Buildings Airports Churches Industrial sites Shopping centers Parking lots Substations Building facades DIMENSIONS Yoke Mount All electrical components warranted by American Electric Lighting's 6-year guarantee PREFERRED SELECTION CATALOG NUMBERS 75 40M SC MT1 66 0443 TL NL 75 40S CA MT1 76 EC 0443 TL NL 75 40S CA MT1 76 TM EC TL NL 75 40M SC MT1 76 TM TL NL 75 25S CA MT1 76 EC 0443 TL NL 75 25S CA MT1 76 TM EC TL NL Vertical Tenon Mount Effective Projected Area (EPA) The EPA for the UltraFlood™ Series 75 is 2.75 sq. ft. Approx. Wt. = 37 lbs. 156 Product Guide For photometric information, visit our website, www.americanelectriclighting.com UltraFlood™ Series 75 Heavy Duty Floodlight 100-400W HPS; 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 7 5 4 0 M C A M T 1 6 6 0 6 4 3 L C T L P C Series 75 UltraFlood Wattage / Source 10 15 17 20 25 31 40 23 100W 150W 175W 200W 250W 310W 400W 250/400W Wired 250W 24 250/400W Wired 400W S HPS M MH RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA (Auto Reg) CT CWI SC SCWA MR Mag Reg (3 Coil) Refer to the ballast matrix on page 173 for compatibility. NEMA Beam Pattern Voltage Ballast 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap Wired 480V Vertical Lamp 76 7H x 6V 66 6H x 6V Horizontal Lamp H6 6H x 6V Refer to Optic Distribution Matrix below for compatibility. Options Mounting (blank) Yoke Mount (standard)1 YG Wraparound Yoke Galvanized TM Tenon Slipfitter1 Paint2 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block3 (blank) Hard wired (standard) TB Terminal Block Factory Wire T2 Wired to L1 and L2 Position T3 3 Wire Operation (L1, N, L2 Position)10 Listing (blank) CS XL UL Listed (standard) CSA Certified No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle4 Starter5 (blank) Open Board (standard) EC Encapsulated plug-in OP Open board plug-in Lamp LC LD Fusing6 SF DF Lamp Included, Clear Lamp Included, Deluxe Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Cord Length* 04 4’ 05 5’ 06 6’ 08 8’ 10 10’ 12 12’ 15 15’ 20 20’ 25 25’ 30 30’ Misc. TL PC BT SS 5H NL PGS SH Cord Type* 63 16-3 44 14-47 43 14-3 23 12-3 *Cord length and type should be combined to form one number. Ex: 0423 Tool-less Entry Photocontrol Included per Voltage Specified4 Removable Ballast Stainless Steel fastener (external) 50 Hertz Ballast Frequency8 NEMA Label Ballistic Shield9 Shorting Cap4 Notes: 1 Painted to match fixture 2 Other colors available, please contact your local American Electric Lighting representative 3 Voids UL and CSA Listing 4 PC, and SH not available with NR option 5 HPS only 6 Voids UL and CSA listing, not available in MT, TT, and DT voltages 7 For 3-wire operation and ground 8 Limited availability, please contact your local American Electric Lighting representative 9 Ships separately 10 Not available in 120V Optic Distribution 10S 15S 20S 25S 40S 17M 25M 40M 76 N N N N N N N N 66 - N N N H6 N N N N N N N N Product Guide 157 UltraFlood™ Series 77 Heavy Duty Floodlight 400-1000W HPS; 400-1000W MH P R O D U C T O V E R V I E W Features: NEMA beam patterns available in a variety of options with horizontal lamp Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Door is hinged and easily removable for quick maintenance Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming UL listing is standard For easy maintenance, tool-less entry is available Suitable for -30°C MH / -40°C HPS Lens is thermal shock and impact resistant tempered glass All electrical components warranted by American Electric Lighting's 6-year guarantee Applications: Auto dealerships Schools Churches Industrial sites Shopping centers Parking lots Substations Building facades DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 77 X1M CA MT1 76 0443 TL NL 77 X1M CA MT1 76 TM TL NL 77 X1S CA MT1 76 0443 TL NL 77 X1S CA MT1 76 TM TL NL Effective Projected Area (EPA) The EPA for the UltraFlood™ Series 77 is 3.97 sq. ft. Approx. Wt. = 65 lbs. 158 Product Guide For photometric information, visit our website, www.americanelectriclighting.com UltraFlood™ Series 77 Heavy Duty Floodlight 400-1000W HPS; 400-1000W MH O R D E R I N G I N F O R M AT I O N Example: 7 7 X I M C A M T 7 7 6 T M Wattage / Source Series 77 UltraFlood 40 400W 75 750W X1 1000W Voltage Ballast S HPS M MH CA CWA (Auto Reg) Refer to the ballast matrix on page 174 for compatibility. NEMA Beam Pattern 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 wired 240 5T4 5 Tap Wired 480V Horizontal Lamp 65 6H x 5V 66 6H x 6V 76 7H x 6V Refer to optic distribution matrix below for compatibility. Options Mounting (blank) Yoke Mount (standard)1 YG Yoke Galvanized TM Tenon slipfitter1 Paint2 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block3 (blank) Hard wired (standard) TB Terminal Block T2 Wired to L1 and L2 T3 3 Wire Operation (L1, N, L2 Position)8 Listing (blank) CS XL UL Listed (standard) CSA Certified No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle NR No Photocontrol Receptacle4 Lamp LC LD Fusing5 SF DF Notes: Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Cord Length* 04 4’ 05 5’ 06 6’ 08 8’ 10 10’ 12 12’ 15 15’ 20 20’ 25 25’ 30 30’ Misc. TL PC SS 5H NL SH Cord Type* 63 16-3 44 14-46 43 14-3 23 12-3 PW Pre-wire (Slip fitter only) *Cord length and type should be combined to form one number. Ex: 0643 Tool Less Entry Photocontrol Included per Voltage Specified4 Stainless Steel fasteners (external) 50 Hertz Ballast Frequency7 NEMA Label Shorting Cap4 1 Painted to match fixture 2 Other colors available, please contact your local American Electric Lighting representative 3 Voids UL and CSA certification 4 PC, and SH not available with NR option 5 Voids UL and CSA listing, not available in MT, TT, & DT voltages 6 For 3-wire operation and ground 7 Limited availability, please contact your local American Electric Lighting representative 8 Not available in 120V Optic Distribution X1S X1M 65 N - 66 N - 76 N Lamp Included, Clear Lamp Included, Deluxe Product Guide 159 Energy Saver Series CES Floodlight 35-150W HPS; 50-175W MH P R O D U C T O V E R V I E W Features: Durable polyester powder paint finish Die-cast aluminum housing Fully gasketed Lens secured by hinged, captive bezel with captive screw or NEMA latch closure High efficiency aluminum reflector Provides broad floodlighting coverage Impact and thermal resistant tempered glass lens UL listing in standard Applications: PREFERRED SELECTION CATALOG NUMBERS Waterfront areas Building facades Residential areas Recreational areas Commercial environments Parking areas Industrial sites Storage areas CES 15S RN 120 LC DIMENSIONS Effective Projected Area (EPA) The EPA for the Energy Saver Series CES is 0.61 sq. ft. Approx. Wt. = 18 lbs. 160 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Energy Saver Series CES Floodlight 35-150W HPS; 50-175W MH O R D E R I N G I N F O R M AT I O N Example: C E S 0 3 S C A 1 2 0 B K Wattage / Source Series CES Compact Energy Saver Floodlight 03 05 07 10 15 17 35W 50W 70W 100W 150W 175W S HPS M MH Refer to the ballast matrix on page 174 for compatibility. Ballast Voltage RN Reactor, Normal Power Factor RH Reactor, High Power Factor XN High Reactance (lag), Normal Power Factor XH High Reactance (lag), High Power Factor CA CWA (Auto Reg) 120 120V Options Mounting (blank) 1/2” Threaded Knuckle Mount WY Wrap Around Yoke Lamp (blank) LC None Lamp Included, Clear Paint (blank) BK WH Misc. TL Tool Less Entry Bronze (standard) Black White Photocontrol Receptacle (blank) None PC Button Photocontrol Product Guide 161 Quartz Flood Series 570 Floodlight 500W Quartz P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance, bronze is standard color Single door access to lamp and electrical components for quick, easy installation and servicing Suitable for -30°C MH / -40°C HPS UL listing is standard Lens is thermal shock and impact resistant tempered glass 570-61/L Applications: Transportation terminals Building facades Sports lighting Parking lots Industrial areas Commercial areas Residential areas Security lighting Fixture Available 570-61/L DIMENSIONS Effective Projected Area (EPA) The EPA for the Floodlight, Series 570 is 0.72 sq. ft. Approx Wt = 3.5 lbs 162 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Clear Lamp Included (120V) Quartz Flood Series 474 Floodlight 1500W Quartz P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance, bronze is standard color Single door access to lamp and electrical components for quick, easy installation and servicing Permanently attached bezel is secured by twin captive spring latches UL listing is standard Lens is thermal-, shock-, and impact-resistant tempered glass for lamp protection Applications: Transportation terminals Building facades Sports lighting Parking lots Industrial areas Commercial areas Residential areas Security lighting Fixtures Available 474-61/L-208V M4 Lamp Included (208V) 474-61/L-240V M4 Lamp Included (240V) 474-61/L-277V M4 Lamp Included (277V) DIMENSIONS Effective Projected Area (EPA) The EPA for the Floodlight, Series 474 is 1.13 sq. ft. Approx Wt = 5.5 lbs Product Guide 163 AmeriSport™ Series ASP Sports Floodlight 400-1500W MH W PP RR OO DD UU CC TT OO VV EE RR VV II EE W Features: Two-piece die-cast aluminum ballast housing mounted to galvanized steel trunnion. Ballast is removable and hinged with captive fastener. Steel trunnion features vertical and horizontal aiming scale with vertical repositioning stop. All external hardware is stainless steel. White corrosion resistant polyester powder finish standard; other architectural colors available. Heavy-gauge anodized reflector with six distributions available. "Flux manager" available for optimal glare and spill light control. Transverse mounting of lamp. Lamp support included. Optical chamber sealed to inhibit entrance of contaminants. Hinged lens is thermal-, shock- and impact-resistant tempered glass. Lens frame is galvanized and secured by stainless steel spring clips for servicing of lamp. US. Patent no. 6,190,023. Canada Patent no. 2,212,014. Fixture mounted by securing trunnion directly to cross arm. Mounting hardware provided. Suitable for -30°C MH / -40°C HPS Applications: UL listed, suitable for wet locations. Below horizontal aiming orientation only. Listed and labeled to comply with Canadian Standards. Stadiums Sports fields Arenas Tracks Courts All electrical components warranted by American Electric Lighting’s 6-year guarantee. DIMENSIONS Effective Projected Area (EPA) The EPA for the Sports Floodlight Series SPF is 3.3 sq. ft. Approx. Wt. = 55 lbs. 164 Product Guide For photometric information, visit our website, www.americanelectriclighting.com AmeriSport™ Series ASP Sports Floodlight 400-1500W MH O R D E R I N G I N F O R M AT I O N Example: A S P X 5 M C A M T 1 G N ASP AmeriSport 40 400W X1 1000W X5 1500W M Metal Halide CA CWA SC SCWA (Pulse Start)1 CT CWI2 Optics Voltage Ballast Wattage / Source Series 120 208 240 277 347 480 MT1 MT2 MT7 TT3 5T8 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 277V 5-tap Wired 480V G General Purpose H Heavy Duty Distribution N M W NX Narrow Beam Medium Beam Wide Beam Narrow Beam with Flux Manager DX Medium Beam with Flux Manager WX Wide Beam with Flux Manager Options Listing (blank) UL Listed (standard) CS CSA Certified3 XL No Listing Fusing4 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Cord Length* 03 3' Cord 05 5' Cord 08 8' Cord Cord Type* 23 12-3 SEO Cord 43 14-3 SEO Cord 63 16-3 SEO Cord Frequency 5H 50 Hertz Ballast Frequency5 Filter CF Charcoal Filter6 Connector 3P 3 Prong Plug7,8,9,10 Quartz Restrike QS Quartz Restrike (Lamp not included) Notes: 1 400W MH only 2 Available in 208 and 240V only 3 Consult factory for CSA availability 4 Single tap only 5 Limited availability, please contact your local American Electric Lighting representative 6 Must use with heavy duty optical 7 Must use mating receptacle, provided by others 8 Not available with 1500W, 120V 9 Use with pre-wired gauges and cross-arms 10 For use with 0363 cord length and type only *Cord length and type should be combined to form one number. Ex: 0523 Lamp LC Lamp Included, Clear (Ships separately) Product Guide 165 Sportslighting Series SPF Sports Floodlight 400W & 1000W HPS, 400W-1500W MH P R O D U C T O V E R V I E W Features: Heavy-gauge, hydroformed, aluminum ballast housing is mounted to integral die-cast monoframe with horizontal degree aiming scale and repositioning locator. Die-cast aluminum socket housing provides vertical aiming adjustment, complete with degree aiming scale and repositioning stop. Heavy-gauge, anodized, aluminum reflectors provide a range of NEMA beam spreads. Optical chamber is sealed to inhibit entrance of contaminants. Hinged lens is heavy-duty thermal shock and impact-resistant, tempered glass. Adjustable mounting bracket standard. Porcelain, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V. Fixture is mounted by securing the integral cross-arm mounting bracket directly to the cross-arm. No additional adapters are required. A 5/8"-11UNC mounting bolt is provided. Exposed bolt length is 1-1/2". UL listed, suitable for wet locations. Listed and labeled to comply with Canadian Standards. Suitable for -30°C MH / -40°C HPS Optional painted heavy duty reflector shroud available to protect the reflector. Applications: All electrical components warranted by AEL’s 6-year guarantee. Stadiums Sports fields Arenas Tracks Courts DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS SPF X5M CA MT1 33 SPF X5M CA MT1 44 SPF X5M CA MT1 66 Dimensions EPA: NEMA 2,3: NEMA 4,5,6: Diameter: NEMA 2,3: NEMA 4,5,6: Length: NEMA 2,3: NEMA 4,5,6: Weight: 53 lbs. 166 Product Guide 2.9 ft.2 (.27 m2) 2.5 ft2 (.23 m2) 23-1/8 (58.7) 21-1/2 (54.6) 30 (76.2) 31-1/2 (80) 24 Kg. For photometric information, visit our website, www.americanelectriclighting.com Sportslighting Series SPF Sports Floodlight 400W & 1000W HPS, 400W MH-1500W MH O R D E R I N G I N F O R M AT I O N Example: S P F X 5 M C A M T 1 5 5 Wattage / Source Series SPF Sports Floodlight 40 400W X1 1000W X5 1500W1 S HPS M MH Voltage Ballast 120 208 220 240 277 347 480 MT1 MT2 MT7 5T4 CA CWA SC SCWA (Pulse Start)2 CT CWI3 120V 208V 220V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V 5-Tap Wired 480V Optics 22 33 44 55 66 2H x 2V 3H x 3V 4H x 4V 5H x 5V 6H x 6V Options Listing (blank) UL Listed (standard) CS CSA Certified4 XL No Listing Bolt LB Extended Bolt for Wood Crossarm Support LT Lamp Support Fusing5 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Connector 3P 3 Prong Plug8,9,10,11 Lamp LC Lamp Included, Clear (Ships separately) Coating TC Non-stick Protective Coating, Black Only Cord Length** 03 3' Cord 05 5' Cord 08 8' Cord Cord Type** 23 12-3 SEO Cord 43 14-3 SEO Cord 63 16-3 SEO Cord **Cord length and type should be combined to form one number. Ex: 0523 Frequency 5H 50 Hertz Ballast Frequency6 Shield GS Glare Shield14 HG Hail Shroud and Glare shield RS Reflector (Hail) Shroud7 Aiming AH Above Horizontal Filter CF Charcoal Filter12 Notes: 1 2 3 4 4 5 6 7 8 9 10 11 12 13 14 Metal Halide only 400W MH Only Available in 208 and 240V only. Not available in HPS Consult factory for CSA availability Must use mating receptacle, provided by others Available in single tap only Limited availability, please contact your local American Electric Lighting representative Heavy duty anodized aluminum shroud Must use mating receptacle, provided by others Use with prewired caged and crossarms For use with 0363 cord length and type only Not available with 1500W, 120V For use with reflector shroud (RS option) only Lamp not included LV and GS not compatible Quartz QS Quartz Restrike13 Paint BK Black WH White Louver LV Internal Louver14 Product Guide 167 Accessories G L A R E S H I E L D S Catalog Approx. Wt. (Lbs.) 2 Number Item RK75 GS BZ RK75 GS LARGE BZ ULTRA FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with Ultra Flood, series 75. Standard finish is bronze. POLYCARBONATE VANDAL SHIELD .6 ULTRA FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with Ultra Flood, series 77. Standard finish is bronze. POLYCARBONATE VANDAL SHIELD .7 .5 RKACP VS COMPACT FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with series 51. Standard finish is bronze.2 COMPACT FLOOD VANDAL SHIELD 75 PGS 40W 77 PGS X1W ACP PGS 40W 75 SERIES BALLISTIC SHIELD, 400W MAX 77 SERIES BALLISTIC SHIELD, 1000W MAX ACP SERIES BALLISTIC SHIELD, 400W MAX RK75 VS RK77 GS BZ RK77 GS LARGE BZ RK77 VS RKACP GS BZ RKACP GS LARGE BZ 168 Effective Projected Area (Sq. Ft.) Product Guide For photometric information, visit our website, www.americanelectriclighting.com 2 2 2 2 2 Accessories For Mounting to Wood Poles S T E E L Catalog Number M O U N T I N G Item B R A C K E T S Effective Projected Area (Sq. Ft.) Approx. Wt. (Lbs.) 9201 SINGLE UNIT BRACKET — Manufactured of 2'' steel pipe with a minimum yield of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .7 5 9254 SINGLE UNIT BRACKET — Manufactured of 2'' steel pipe with a minimum yield of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .7 13 9204 SINGLE UNIT BRACKET — Fixture bracket is 3'' 3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of 2'' steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .8 141/4 9205 TWIN UNIT BRACKET — Each fixture bracket is 3'' 3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of 2'' steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .8 271/4 9252 9252-G TWIN UNIT BRACKET — Manufactured of 2'' steel pipe with a minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. 1.4 24 THREE UNIT BRACKET — Manufactured of 2'' steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. 1.9 27 (Galvanized) 9253 9253-G (Galvanized) NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G.) Product Guide 169 Accessories M O U N T I N G Catalog Number 170 A D A P T E R S Item Approx. Wt. (Lbs.) 9902-H ALUMINUM POLE-TOP MOUNT Slipfitter mounting. Positive three-point mounting support and corrosion-resistant hardware. Fits 2'' or 21/2'' pipe (2'' pipe intrudes 31/16'', 21/2'' pipe intrudes 23/4''.) Furnished with mounting bolts, set screws, and compression fitting for cable entry. Top cover removable for wiring. 3 9906 PIPE CLAMP MOUNT Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 11/2'' or 2'' pipe installations. 3 9909 PIPE CLAMP MOUNT Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 3'' pipe installations. 5 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Accessories For Mounting to Steel Poles S T E E L Catalog Number M O U N T I N G Item B R A C K E T S Effective Projected Approx. Area (Sq. Ft.) Wt. (Lbs.) 9333 THREE ARM POLE-BRACKET—12'' spread, arms @ 120° 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime coated finish. 1.2 34 9343 FOUR ARM POLE-TOP BRACKET—48'' spread, arms @ 90°, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. .90 45 9352 TWO ARM POLE-TOP BRACKET — 30'' spread, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. .87 21 9353 THREE ARM POLE-TOP BRACKET — 30'' spread between tenons, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. 1.7 34 9354 FOUR ARM POLE-TOP BRACKET — 30'' spread between tenons, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. 2.3 45 NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G) For Steel, Aluminum, Fiberglass and Wood Poles Refer to the Pole Section or Call Your Local American Electric Lighting Representative. Product Guide 171 Options and Accessories AVA I L A B I L I T Y GLARE SHIELDS MOUNTING BRACKETS MOUNTING ADAPTERS POLE-TOP MOUNTING BRACKETS SPORTS FLOOD ACCESSORIES Flood Glare Shield, Dark Bronze Large Flood Glare Shield, Dark Bronze Upper Visor, Glass Lens and Glass Ring for NEMA 4, 5, 61 Upper Visor, Glass Lens and Glass Ring for NEMA 2, 31 Polycarbonate Vandal Shield Ballistic Shield Vertical Single Unit Bracket (19-3/4”H) 4, 5 Vertical Single Unit Bracket (23”H) 4, 5 Crossarm Single Unit Bracket 4, 6 Crossarm Twin Unit Bracket 4, 6 Vertical Twin Unit Bracket 4, 5 Galvanized Vertical Twin Unit Bracket 4, 5 Vertical Three Unit Bracket 4, 5 Galvanized Vertical Three Unit Bracket 4, 5 Aluminum Pole-Top Mount Pipe Clamp Mount for 1-1/2” - 2” Pipe Pipe Clamp Mount for 3” Pipe Three-Arm Pole-Top Bracket (12” spread) Two-Arm Pole-Top Bracket (30” spread) Three-Arm Pole-Top Bracket (30” spread) Four-Arm Pole-Top Bracket (30” spread) Four-Arm Pole-Top Bracket (48” spread) Crossarm Adapter Crossarm Adapter, 45º Bottom Internal Louver, Glass Lens and Lens Ring for NEMA 4, 5, 6 Bottom Internal Louver, Glass Lens and Lens Ring for NEMA 2, 3 Radius Wall Bracket, Dark Bronze Steel Angle Bracket, Dark Bronze Mounting Bracket (for 2” Schedule 40 pipe) Pole-Top Tenon Adapter for 2-3/8” to 2-7/8” OD Tenon Wood Pole, 2-light Wood Pole, 3-light Wood Pole, 4-light ACP 75 77 RKACP GS BZ RK75 GS BZ RK77 GS BZ RKACP GS LARGE BZ RK75 GS LARGE BZ RK77 GS LARGE BZ - - - RKACP VS ACP PGS 40W2 9201 9254 9204 9205 9252 9252-G 9253 9253-G 9902-H 9906 9909 9333 9352 9353 9354 9343 RK75 VS 75 PGS 40W2 9201 9254 9204 9205 9252 9252-G 9253 9253-G 9902-H 9906 9909 9333 9352 9353 9354 9343 RK77 VS 77 PGS X1W3 9201 9254 9204 9205 9252 9252-G 9253 9253-G 9902-H 9906 9909 9333 9352 9353 9354 9343 - - - ASP - 9/16" DIA. ATS U SPF TSU Furnished with weather-tight cord grip for 14-3 SO cord. (Grip for 12-3 SO optional.) Wire Access ACRA45 ACRA 172 Product Guide For photometric information, visit our website, www.americanelectriclighting.com SPF20 GS GL OPT U SPF23 GS GL OPT U ACRA ACRA45 U - - SPF20 LV GL U SPF23 LV GL U ARWB BZ U ASAB BZ U - ASPMB OPT U ATS U - Notes: 1 Louver and glare shield cannot be used simultaneously 2 400W lamp maximum 3 1000W lamp maximum 4 Brackets designed to accommodate fixtures with a maximum weight of 65 lbs. and an EPA of 4.0 5 Tenon mount only 6 Yoke mount only Standard finish is dark bronze, contact American Electric Lighting for other finishes ARWB BZ U SPF - 5/8" Clearance Hole SPFTS U ACRW2 ACRW3 ACRW4 Floodlighting B A L L A S T ACRW2 M AT R I C E S ACRW4 ACRW3 ASAB APSMB OPT U ACP Series Watts 07S 10S 13S 14S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M 120 CA,CT,RH,RN CA,CT,RH,RN RH,RN RH,RN CA,CT,RH,RN CA CA CA XH,XN,CA CA CA CA CA,CT CA,CT 208 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA CA CA,CT CA 240 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA RH,RN,CA CA CA, XH, XN CA CA CA CA,CT CA,CT 277 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA CA CA,CT CA 347 XH,XN CT,XH,XN CA CA CA,CT,SC CA - 480 XH,XN CA,XH,XN CA,XH,XN CA CA CA CA,SC CA CA CA,SC DT2 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA, CA,XH,XN CA CA,CT,SC CA,CT CA,CT MT1 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC MT2 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC ACP Series continued Watts 07S 10S 13S 14S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M MT7 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC TT3 CT,XH,XN CT,XH,XN CA CA CA,CT CA,CT - 5T4 CA CA CA CA Product Guide 173 Floodlighting B A L L A S T M AT R I C E S Series 75 Watts 10S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M 120 CA,CT,RH,RN CA,CT,RH,RN CA CA CA CA,XH,XN CA CA CA CA,CT CA,CT 208 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA CA CA,CT CA 240 CA,CT,XH,XN CA,CT,XH,XN CA CA,RH,RN CA CA,XH,XN CA CA CA CA,CT CA,CT 277 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA, CA CA CA,CT CA TT3 XH,XN,CT CA CA CA,CT CA,CT - 5T4 CA CA CA CA 347 CT,XH,XN CA CA CA,CT,SC CA - 480 CA,XH,XN CA,XH,XN CA CA CA CA,SC CA CA CA,SC DT2 CA,CT,XH,XN CA CA CA CA,XH,XN CA CA,CT,SC CA CA,CT CA,CT MT1 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC Series 75 continued Watts 10S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M MT2 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA MT7 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA Series 77 Watts 40S 40M 75S X1S X1M 120 CA,CT,XN,XH,MR CA,CT,SC CA CA,CT CA,SC 208 CA,CT CA,CT,SC CA CA,CT CS,SC 220 RN,RH CA CA 240 RH,RN,CA,CT,MR CA,CT,SC CA CA,CT CA,SC TT1 CA CA CA,SC TT7 CA CA CA,SC 277 CA,CT CA,SC CA CA,CT CA,SC 480 CA,MR CA,CT, CA,CT CA,SC DT1 CA,CT,,XN,XH,MR CA,CT CA CA,CT CA,SC DT2 CA,CT,,XN,XH,MR CA,CT CA CA,CT CA,SC Series 77 continued Watts 40S 40M 75S X1S X1M MT7 CA,CT CA,SC CA CA,SC MT8 CA,CT CA,SC CA CA,SC TT3 CA CA CA CA,SC 347 CA CA CA,SC Energy Saver Series CES Watts 03S 05S 05M 07S 07M 10S 10M 15S 15M 17M 174 120 RN,RH RN,RH XN,XH RN,RH XN,XH RN,RH XN,XH RN,RH XN,XH CA 208 CA Product Guide 240 CA 277 XN,XH XN,XH XN,XH XN,XH CA DT2 CA MT1 CA MT2 CA MT7 CA For photometric information, visit our website, www.americanelectriclighting.com DT3 MR CT - DT4 MR CT - MT1 CA,CT CA,SC CA CA,SC MT2 CA,CT CA,SC CA CA,SC