HL-2161_forPDF.qxd:HScapes- Infrastructure

advertisement
Outdoor Substation
SPECIALTY
Outdoor Substation
Absence of glare
Light is refracted upward and not toward the
operator’s/inspector’s eyes.
Permanence
High utilization of light output
The upward distribution of more than 60% of total lamp lumens
provides effective illumination for overhead buss bars, disconnect
switches, insulators and fuses. Vertical and horizontal light enables
quick identification of open switches from ground level.
Excellent maintained illumination
Original light output can be restored by thorough cleaning, while the
natural cleansing action of rain maintains continuing high operating
output. Sealed gasket assemblies around the top and bottom of the
refractor keep the interior of the unit dirt- and weather-tight for many
years.
The one-piece prismatic light controlling element
is molded Endural® glass which is manufactured
to withstand the extreme temperature gradients
encountered outdoors. Metal fixture parts are
composed of stainless steel, cast and spun
aluminum to withstand severe weather.
Light shields
Inner shields for 90°, 120° and 180° light cutoff
are available for use on substations near
residential areas. Shields can be ordered with
new fixtures, or purchased separately and
installed in existing ones. Shields may be rotated
within fixtures to the most effective position.
Safety when relamping
Choice of lamps
Unit is mounted on bracket or post top below
high voltage equipment to prevent contact with
dangerous voltages when relamping.
From 70W to 400W HPS, 175W to 400W metal halide or mercury.
300W or 500W incandescent lamps may also be used.
On-site adjustment of light distribution
While lamp is on, the optical assembly can be
rotated up or down to obtain maximum
candlepower to reach disconnect switches and
other overhead structures. After adjusting, a set
screw locks the unit in place.
82
Ordering Information
INFRASTRUCTURE
How to Construct a Catalog Number
Example:
Product Catalog
SUA
100HP
12
TL
PR
1
2
3
4
5
6
LUMINAIRE
WATTAGE
VOLTAGE
OPTICS
OPTIONS
ACCESSORIES
SU1A
SU2A
SU2B
070HP
100HP
15AHP
15BHP
175MH
250HP
250MH
400HP
400MH
12
20
24
27
34
NB
TL
PR
LAMP
F1
F2
SD-59
SD-60
SD-51
07233
0871-CA
Typical Applications
Catalog Number Information
• Substations
STEP 1:
Features
SU1A
Substation (70-175W)
SU2A
Substation (250-400W)
1
Substation (optic)
SU2B
1 Optics only without bracket assembly.
Non-ballasted for 300, 500INC and
400MH (MV)
• Canopy luminaire for high visibility
• Uplight and downlight component
STEP 3:
LUMINAIRE
STEP 4: OPTICS
152mm
(6.00”)
191mm
(7.50”)
TL
Top lens
416mm
(16.38”)
STEP 5:
SU1
Maximum Weight: 504 kg., (50 lbs.)
SU2
Maximum Weight: 604 kg., (60 lbs.)
PR
STEP 2:
SOURCE
070HP1
100HP1
15AHP1
15BHP1
175MH1
250HP2
400HP2
250MH2
400MH2
1 SU1A size
2 SU2A size
AND
WATTAGE
70W HPS
100W HPS
150W/55V HPS
150W/55V HPS
175W MH or MV
250W HPS
400W HPS
250W MH or MV
400W MH or MV
OPTIONS
Photocontrol (Not Available
with SU2B or 480V,
Use as Suffix on Third
Component of Catalog)
Approvals
• UL/CUL wet locations
VOLTAGE
12
120V
20
208V
24
240V
27
277V
34
347V
48
480V
Non-ballasted
NB1
1 Optics and bracket assembly
524mm
(20.63”)
Lamp Types
• 175 - 400 watt metal halide
• 70 - 400 watt high pressure sodium
LAMP
STEP 6:
LAMP
F1
F2
SD-59
SD-60
SD-51
07233
0871-CA
6" sq
5"
ACCESSORIES
Appropriate Lamp Shipped
Single Fusing Kit for 120277V
Double Fusing Kit for 208480V
90º Shield
120º Shield
180º Shield
Bracket (included with all
except SU2BNB)
Corner adapter Bracket
Slip-fit for
1.94" O.D.
4.31"-18 Elastic stop nuts
1.5" Tapered pipe thread
2.25"
5"
.75" Tapered pipe thread
20.38"
21.63"
1" Tapered pipe thread, 2 holes
|
HOLOPHANE® Outdoor Lighting
INFRASTRUCTURE
| Outdoor Substation
83