Digital RTD Thermomete DP95 Series Discontinued Product Click Here for the DP97 Series (Possible Substitute) Shown with PRP-1, Precision 100Ω Pt RTD Probe 0.05°C Accuracy for Precision Measurement 0.001°C Resolution Microprocessor Based Accepts ITS-90, IPTS-68, Callendar Van Dusen Probe Linearization Up to 4 RTD Inputs for Measurement or Comparison Uses 3- or 4-Wire RTD Probes from 25 Ohms to 1000 Ohms Ro Built-In Autoscan Function Display Data in °F/°C/K/Ω Rugged Metal Enclosure EMI/RFI Shielded Applications Metrology Departments Quality Assurance Labs Standard Temperature Measurement Precision Measurements Pharmaceutical Processes Autoclaves The DP95 is an RTD thermometer that combines high precision at an extremely competitive price. The DP95 features 0.001°C resolution with an accuracy of 0.05°C over the entire temperature range of -200 to 850°C. It accepts up to four RTD probe inputs. Each of the four probes can be individually linearized based on either: entering Ro and selecting alphas are selected from 25, 385, 390, 392 or 3916; or entering appropriate coefficients may when ITS-90, IPTS-68 or the Callendar Van Dusen linearization is selected. The DP95 is capable of K-101 DP95 Series $ 2705 Basic Unit Shown smaller than actual size. providing probe resistance to a resolution of one part per million. It also computes advanced floating-point mathematical algorithms and displays conversion to temperature (Ω to °C). Optional interface includes RS-232C communications interface which allow the user to interface directly with a PC or can be used for printing or datalogging. A 1 mV/°C analog signal is also available for probe 1, which allows direct connection to recording devices. When used with the Precision Laboratory Probe as the standard probe (probe 1), the total system accuracy is less than 0.10°C up to 200°C and less than 0.20°C at 400°C. The Precision Laboratory Probe comes standard with a NIST Traceable Calibration Report which provides temperature vs. resistance polynomial constants that are programmed into the DP95, virtually eliminating probe error. The report includes resistance vs. temperature data over the entire range of -183 to 500°C in one-degree increments. Digital RTD Thermometer Probe Number Display identifies probe being measured Full six digit display with large LED digits and polarity indication Engineering units display also provides prompts and messages Sealed and scratchproof front panel with clearly labeled keys Key to select function/ display mode Rugged metal enclosure; EMI/RFI shielded design Removable configuration panel makes setup fast and easy, and prevents unauthorized changes when removed ALL MODELS AVAILABLE FOR FAST DELIVERY! To Order (Specify Model Number) Specifications Inputs: Isolated and floating input for each channel, four maximum Range: -199.999 to 850.000°C Input Protection: ±130 V Isolation (CMV): 600 V minimum, 1000 V typical Accuracy: 0.05°C Optional Analog Output (probe 1 only): 1 mV/°C Operating Environment: 0 to 60°C (32 to 140°F), 0 to 95% RH non-condensing Storage: -40 to 85°C (-40 to 185°F) Dimensions: 114 x 203 x 330 mm D (4.5 H x 8 W x 13"), Bench top with tilt stand Weight: 7.3 kg (16 lb) Gain Tempo: 1 PPM/°C typical, 2 PPM/°C maximum CMRR: greater than 160 dB typical PRP-1 4-WIRE SENSOR SPECIFICATIONS Calibration: -183 to 420°C (-297 to 932°F) Range: -183 to 480°C (-297 to 896°F); PRP-1 probe leads, 260°C (500°F) max. Stability: >0.1°C per year Ro: 100Ω nominal Alpha: 0.00392 Ω/Ω/°C Calibrated Accuracy: 0.010°C at -100°C; 0.007°C at 0°C; 0.024°C at 200°C; 0.033°C at 420°C Construction: 1⁄4 " O.D. 300 mm (12") long SS sheath, 4-wire (style 3) construction with 1.8 m (6') Teflon insulated lead wire Model Number DP95-(*)-(**)-31-(2)-(3)-(4) Price $2705 DP95-(*)-(**)-41-(2)-(3)-(4) 2705 PRP-1 600 Description High precision RTD Thermometer High precision RTD Thermometer Precision Laboratory Probe To order specify model number, (*) analog option,(**) communication output option, (2) second probe input, (3) third probe input; (4) fourth probe input. Insert code number(s) from output and input option tables below. 220 Vac or 12 Vdc Power options are available; Consult Sales Department. Each unit must be factory calibrated at the time of order, including all output and input options. Ordering Example: DP95-A-XX-41-31-31-31 is a DP95 with analog output, no communications output, a 4-wire 100 Ω RTD input card for channel one, 3-wire 100 Ω RTD input cards for channels two, three and four, $2705 + 390 + 415 + 415 + 415 = $4340. Analog Output Option Cards (Not Field Installable) Order Add’l Suffix Price Description -X std No Analog Output -A $390 Analog Output 1 mV/°C for probe 1 Communications Output Option Cards (Not Field Installable) Order Add’l Suffix Price Description -XX std No Communications Output -RS $440 RS-232C Data Output Probe Input Cards (Not Field Installable)† Order Add’l No. of Suffix Price Wires -31 $415 3 -41 415 4 † Nominal Ro 100 Ω 100 Ω 4-wire 25 Ω, 3- or 4-wire 200 Ω, 500 Ω and 1000 Ω input cards are available. Contact Engineering Department for details. K-102 One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com www.omega.com UNITED KINGDOM www. omega.co.uk Manchester, England 0800-488-488 UNITED STATES www.omega.com 1-800-TC-OMEGA Stamford, CT. FRANCE www.omega.fr Guyancourt, France 088-466-342 CANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA CZECH REPUBLIC www.omegaeng.cz Karviná, Czech Republic 596-311-899 GERMANY www.omega.de Deckenpfronn, Germany 0800-8266342 BENELUX www.omega.nl Amstelveen, NL 0800-099-33-44 More than 100,000 Products Available! Temperature Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire Flow and Level Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters pH and Conductivity Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation Data Acquisition Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers Pressure, Strain and Force Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves Heaters Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters click here to go to the omega.com home page EPG05