SEE MORE AT SORInc.com Request Quote RF Capacitance Level Controls Features and Benefits CAC-8A-00-6 681R7 • Reliability • 316SS, Telflon® or Kynar probes • Low maintenance costs • Can be used in virtually every type of chamber • No moving parts • Set point/span are completely adjustable • Interface measurement with on/off and continuous output • Withstands temperatures up to 400oF (204oC) • Unaffected by changes in pressure, temperature, specific gravity, vapor or density • Versatile - can be used with both conductive and non-conductive substances. Manages a variety of liquids, granular solids, powders and slurries. • Withstands pressure up to 2000 psig (138 bar) Agency Listings/Certification • Select models with CSA, FM, IECEx, INMETRO, Rostechnadzor (RTN) • Meets most code and customer requirements. • Dielectric range is unlimited Form 1100 (12.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 1/28 RF Capacitance Level Controls Principle Non-Conductive Substances Operating Principle RF Capacitance level controls are based on an electronic device called a capacitor. The capacitor is a device that stores energy. This energy is not stored in the probe; rather, the RF Capacitance level control is merely measuring how much energy can be stored. The amount of capacitance the RF Capacitance level control is measuring is extremely small and is measured in picofarads (1 X 10-12) farads. The structure of the capacitor actually changes in a level application. One plate is the probe and the other is the wall of the tank (see following figure). These do not change, nor does the distance between them. The only thing that changes is the dielectric constant. Air has a dielectric constant of one; anything else you measure will have dielectric value greater than one. Bare Metal Probe The capacitor is made up of two conductive plates parallel to each other. Separating the two plates is an insulator. Metal Tank Wall Hydrocarbon Conductive Plate Insulating Medium Conductive Plate The amount of energy a capacitor can store is influenced by several things. First, a larger plate area results in more space to store energy. Second, more space between the plates reduces the amount of energy storage. Finally, a higher dielectric constant media can contain more energy than a lower dielectric media. The dielectric is where the actual capacitance is developed. The following chart shows the dielectric constant and conductivity for some sample materials. When the substance level increases, the dialectic of the substance is replacing the air and causes the capacitance to increase. The preset capacitance value is equal to the set point level wanted and trips a switch when the level is reached. The transmitter creates a linear output in relationship to the capacitance measured. Conductive Substances The substance between the two plates has to be an insulator in order to have a capacitor. When a conductive material is between the plates, an electrical short is created. This, in turn, signals the level transmitter to indicate a high level. A Teflon insulator around the sensor will prevent this from happening, as the figure below demonstrates. Insulated Probe Water Substances are considered either conductive or non-conductive. Non-conductive materials have a dielectric less than 10 or a conductivity less than 10µsiemens/cm. Conductive materials have a dielectric constant greater than 10 or a conductivity greater than 10 µsiemens/cm. Interestingly, there is a similar relationship between dielectric constant and conductivity. Non-conductive substances tend to have low dielectric constants and conductive substances tend to have high dielectric constants. 2/28 Registered Quality System to ISO 9001 An electrical connection is created through the conductive substance from the tank wall and the Teflon probe. When the level in the tank rises, the capacitor is created by the metal probe rod, the substance being measured and the probe insulator (Teflon), where the sensor rod and substance are the plates and insulator is the dielectric. This means that rather than measuring the dielectric of the substance, the dielectric of the probe where it is covered by the substance is being measured. | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls Principle Restrictions of RF Sensitive to changes in material dielectric (Note: dielectric compensation additives help, but the liquid can stratify.) Normally needs field calibration, which requires a change in level Dependent on contact with the substance being measured Conductive coatings can build up on the sensor and create false readings The Difference Between RF Capacitance and RF Admittance When there is a conductive coating on the probe, a non-RF unit will indicate the level at the top of the coating. By looking at the conductivity, an RF system can reduce the error caused by the coating (see following figure). Consider this: At the actual level, the amount of capacitive reactance (impedance) is low because the space between the tank wall and probe is filled with a conductive liquid. However, at the coating on the probe, there is also a large air space between the probe and tank wall. This air space results in a high amount of capacitive reactance. RF Unit Contrary to popular belief, there really isn’t an application difference between RF Capacitance and RF Admittance. The only difference is in the electronics; the overall performance of the unit remains the same. That’s where the “RF” part comes in, as the following will explain: RF measurement is actually measuring capacitance, as well as capacitance reactance (impedance). The energy (Radio Frequency) is traveling from one conductive plate to the other. The following equation represents capacitance reactance: Coating High Xc Low Xc Level Xc = 1 2πfc where Xc = Capacitance Reactance (Ohms) 2π = Radians in a 360o cycle of AC (alternating current) f = Frequency of AC (hertz) C = Capacitance of system (in farads) Form 1100 (12.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 3/28 RF Capacitance Level Controls Principle The Difference Between RF Capacitance and RF Admittance Look at the formula for capacitive reactance. Since we are striving to measure the capacitance, C cannot change, and 2π is a constant and cannot change. The only thing left we can change is the frequency. If the frequency is increased (RF), the capacitive reactance decreases. The level is represented on the vertical axis in these two graphs. Changes in the resistance are represented on the horizontal axis. A vector representing a combination of the two (impedance) is shown to the left. The inverse of this graph is shown below. As you can see, an “admittance” measurement is just the inverse of a capacitance measurement. The important part, as previously stated, is the “RF.” Capacitive Reactance Impedance Capacitive Susceptance Admittance Resistance Conductance Use this chart to select the RF instrument that best meets your needs. Designator Line Power Loop Power Integral Mount Electronics 651 Pages 5-6 651 Pages 5-6 Integral Mount Electronics with Sensor Monitor (Self-Test) 681 Pages 7-8 681 Pages 7-8 Remote Mount Electronics with Sensor Monitor (Self-Test) 681 Pages 7-8 681 Pages 7-8 660 Pages 9-10 N/A Single-Point Sensing Multiple-Point Sensing Alarm or Pump Control 4/28 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls RF Switches Single Point 651 Single-Point RF Switch The 651 provides basic, single-point switching for use as an alarm or indicator. It’s virtually immune to process coatings on the probe, making it a useful solution for many tough level applications. This immunity, combined with the absence of any moving parts, makes the 651 well suited for applications that are difficult for other technologies. Features Economical point sensing Suitable for 12 VDC service FM Approved, CSA Certified hazardous locations, IEC Certified Field-selectable failsafe Product Specifications Input Power - Line Input Power - Loop Output Type - Line 12-28 VDC 10A DPDT, 250 VAC 10A DPDT, 30 VDC DC rating shown for resistive loads 5A DPDT for 12 VDC input power Output Type - Loop Loop Resistive 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC 12 VDC 8 mA (alarm), 16 mA (normal) Response Time 0.5 seconds Enclosure Environmental Rating NEMA 4X; IP65 Electrostatic Discharge Protection Line Surge Suppression 8000 volts (Line) 4000 volts (Loop) 1000 volts line voltage EMC Conduit Connection 3/4” NPT Ambient Temperature Range -40 to 160oF (-40 to 71oC) Process Temperature Range Probe Dependent Maximum Process Pressure Weight Probe Dependent 780 ohms maximum @ 24 VDC Adjustment Range Sensitivity 0 to 1000 pF 0.5 pF Repeatability0.5% FailsafeField-selectable Maximum Current Draw (line power) Form 1100 (12.15) ©SOR Inc. 12 VDC - 100 mA 24 VDC - 50 mA 120 VAC - 20 mA 240 VAC - 10 mA SORInc.com 2.5 lbs. (1.2 kg) | 913-888-2630 | Registered Quality System to ISO 9001 5/28 RF Capacitance Level Controls How to Order The 651 consists of two parts. The first is the electronics and housing. The second is the probe. For probe types and model numbers, see pages 21-25. Model Number System 651 K-7-TTYY 2 651 RF Admittance Switch with 120 VAC power supply, oversized nameplate and epoxy-coated housing. Power Supply 1 12 VDC 5 24 VDC 6 120 VAC 7 240 VAC 8 12 - 28 VDC 9 (Loop) *Electronics and probe must have the same agency to maintain the listing integrity (i.e. CS or AI electronics with CS probe, or FM or FI electronics with FM probe). 651K 7 Accessories & Certificates Al CSA Intrinsically Safe* CS CSA Explosion Proof Listing* Fl FM Intrinsically Safe* FM FM Explosion Proof Listing* MB IEC Certified Intrinsically Safe* NM INMETRO approved* OD 60-second time delay ON, 0.5-second delay OFF OF 60-second time delay OFF, 0.5-second delay ON PP Fiber tag with customer-specified tag information PY Powder Coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) RR SS wired on nameplate with customer-specified information TT SS nameplate permanently affixed to housing with customer-specified tag information V V Fungicidal varnish applied to housing exterior YY Epoxy coating applied to housing exterior (200 hours-salt spray) C1 C3 C4 C6 Individual Certificates Certificate of Calibration Inspection Compliance/Conformance Insulation Resistance TT YY Model Number Agency Approval Agency 6/28 Safety Method Approval Model(s) FM Explosion Proof Intrinsically Safe CSA Explosion Proof Intrinsically Safe IEC Intrinsically Safe Class I, Groups C, D Class II, Groups E, F, G Class III, Division 1 Class I, Groups A, B, C, D Class II, Groups E, F, G Class III, Division 1 Class I, Groups C, D Class II, Groups E, F, G Class III, Division 1 Class I, Groups A, B, C, D Class II, Groups E, F, G Class III, Division 1 Ex ia IIB T4 651Kx-FM INMETRO Ex ia IIB T4 651K9-NM Intrinsically Safe Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com 651Kx-FI 651Kx-CS 651K9-AI 651K9-MB Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls RF Switches Single Point 681 Single-Point RF Switch with Self Test Available as an integral or remote-mounted unit, the 681 provides single-point switching, and with its many safe and operation features, is well suited for demanding industrial applications. Its “Self-Check” function constantly monitors circuit and probe integrity. A dedicated relay (line powered) or current shift (loop powered) indicates if the unit is not functioning properly. An optional, adjustable differential provides control of two set points with one relay, which gives the 681 pump and valve control for maintaining correct process levels. Features Continuous self testing (Self-Check) verifies operation of the unit Optional adjustable differential for pump/valve control Available as integral or remote-mounted Field-selectable failsafe Optional on/off time delay eliminates effects of turbulence Resists process media coating Product Specifications Input Power - Line Input Power - Loop 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC, 12 VDC Repeatability0.5% 10-30 VDC Maximum Current Draw (line power) 12 VDC - 100 mA 24 VDC - 100 mA 120 VAC - 25 mA 240 VAC - 13 mA Output Type - Line Alarm 10A DPDT, 250 VAC 10A DPDT, 30 VDC Sensor Monitor 10A DPDT, 250 VAC 10A DPDT, 30 VDC DC rating shown for resistive loads Output Type - Loop Alarm Sensor Monitor Loop Resistance FailsafeField-selectable Response Time 0.1 second Enclosure Environmental Protection Electrostatic Discharge Protection 8 mA (Alarm), 16 mA (Normal) 24-27 mA 456 ohms maximum @ 24 VDC Adjustment Range Sensitivity Adjustment Range (Adjustment Differential) Form 1100 (12.15) ©SOR Inc. 0 to 1000 pF NEMA 4X; IP65 8000 volts (line) 4000 volts (loop) Line Surge Suppression 1000 volts line voltage EMC Conduit Connection 3/4” NPT Maximum Remote Distance from Sensor 150 ft. (45.7 m) 0.5 pF Range I: 0 to 300 pF 0.5 pF sensitivity Range II: 300 to 1000 pF 1.0 pF sensitivity SORInc.com Ambient Temperature Range Probe Dependent Maximum Probe Pressure Probe Dependent Weight 3 lbs. (1.4 kg) plus 2 lbs. (1 kg) for remote | 913-888-2630 | Registered Quality System to ISO 9001 7/28 RF Capacitance Level Controls How to Order The 681 consists of two parts. The first is the electronics and housing. The second is the probe. For probe types and model numbers, see pages 21-25. Model Number System 681 K-7-TTYY The 681 RF Admittance Switch with 120 VAC power supply, oversized nameplate and epoxy-coated housing. 2 Electrical Housing Integral Housing K Remote housing: 150 ft. (45m) maximum R Order remote cable part #2924-113 and specify length in feet 5 6 7 8 9 1 Power Supply 12 VDC 24 VDC 120 VAC 240 VAC 10 to 30 VDC (Loop) 3 AD Adjustable differential (do not use DT accessory) BK Remote electronics flat-surface mounting bracket (R housing only) PK Pipe mounting kit - BK accessory required (R housing only) PP Fiber tag with customer-specified information PY Powder Coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) RR SS wired-on nameplate with customer information TT SS nameplate permanently affixed to housing with customer-specified information VV Fungicidal varnish applied to housing exterior YY Epoxy coating applied to housing exterior (200 hours-salt spray) C1 C3 C4 C6 Individual Certificates Certificate of Calibration Inspection Compliance/Conformance Insulation Resistance 681 K 7 Accessories & Certificates TT YY Model Number Agency Approval There are no third-party approvals at this time. 8/28 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls RF Switches Multi-Point 660 Series Multi-Point RF Switch The 660 Series provides the options of multiplepoint switching plus narrow and wide differential switching. By combining these features, the 660 Series units can be used for a wide variety of control needs. The available switching combinations are designed to provide multiple alarms, pump/valve control, or a combination of alarms and equipment control. The 660 Series makes it possible to combine up to four singlepoint devices into one package for lower costs and reduced maintenance. Features Up to 4-point indication Suitable for 12 VDC service FM Approved and CSA Certified for hazardous locations Field-selectable failsafe Resists process media coating Switching Combinations The 660 Series has eight different combinations of fixed differential and/or adjustable differential switching points. Each unit is equipped with one of four discreet switching points. These points can be used to provide true point level sensing with no level differential, or latched together to provide wide, adjustable differential. See page 11 for available combinations. Required combinations are selected using step 1 in the How to Order chart on page 10. Product Specifications Input Power 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC, 12 VDC Output Type 10A DPDT, 250 VAC 10A DPDT, 30 VDC DC rating shown for resistive loads Adjustment Range Sensitivity 0 to 2000 pF 0.5 pF Repeatability0.5% FailsafeField-selectable Maximum Current Draw Response Time Time Delay (optional) Form 1100 (12.15) ©SOR Inc. 12 VDC - 245 mA 24 VDC - 123 mA 120 VAC - 74 mA 240 VAC - 36 mA 0.5 second (standard) 0 to 30 seconds SORInc.com Enclosure Environmental Protection Electrostatic Discharge Protection Line Surge Suppression Conduit Connection Maximum Remote Distance from Sensor NEMA 4X; IP65 8000 volts 1000 volts line voltage EMC 1” NPT(F) 4000 feet (1219.2 m) Ambient Temperature Range -40 to 160oF (-40 to 71oC) Process Temperature Range Probe Dependent Maximum Probe Pressure Probe Dependent Weight J Housing: 9 lbs. (4.1 kg) R Housing: 11 lbs. (5 kg) W Housing: 6 lbs. (2.7 kg) | 913-888-2630 | Registered Quality System to ISO 9001 9/28 RF Capacitance Level Controls How to Order The Series 660 is comprised of two parts. The first is the electronics and housing. The second is the probe. Refer to pages 21-25 for probe model number. Model Number System 3 66 3 J5-TDVV 663 RF Admittance 3-point switch with 12 VDC power supply, time delay and fungicidal varnished housing. Electrical Housing Integral housing J Explosion-proof remote housing (4000 feet [1219.m] maximum) R 2 Switching Combination Power Supply 5 6 7 8 12 VDC 24 VDC 120 VAC 240 VAC 4 1 See page 11 for switching combinations. Single fixed differential switching point 1 Two fixed differential switching points 2 Three fixed differential switching points 3 Four fixed differential switching points 4 Single adjustable differential switching High-level fixed differential point and adjustable differential switching 5. 6 Single adjustable differential and low- level fixed differential point switching 7 High- and low-level fixed differential points and adjustable differential switching 8 *Electronics and probe must have the same agency to maintain the listing integrity (i.e. CS or AI electronics with CS probe, or FM or FI electronics with FM probe). 66 3 J 5 Accessories & Certificates BK Remote electronics flat surface mounting bracket (R housing only) CS CSA explosion-proof listing* FM FM explosion-proof listing* PK Pipe mounting kit- BK accessory required (R housing only) PP Fiber tag with customerspecified information PY Powder Coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) RR SS wired-on nameplate with customer-specified information TD Time delay for each fixed differential set point TT SS nameplate permanently affixed to housing with customer-specified information VV Fungicidal varnish applied to housing exterior YY C1 C3 C4 C6 Epoxy coating applied to housing exterior (200 hours-salt spray) TD VV Individual Certificates Certificate of Calibration Inspection Compliance/Conformance Insulation Resistance Model Number Agency Approval Agency 10/28 Safety Method FM Explosion Proof CSA Explosion Proof Approval Model(s) Class I, Groups B, C, D Class II, Groups E, F, G Class III, Division 1 Class I, Groups C, D Class II, Groups E, F, G Class III, Division 1 66x-Jx-FM 66x-Jx-FM Registered Quality System to ISO 9001 66x-Jx-CS 66x-Rx-CS | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls RF Switches Multi-point Connection Cable Remote units require #22AWG shielded twisted pair cable to connect the control to the probe. The maximum length of this cable is 4000 feet (1219.2m). A 25 ft. (7.6m) cable is supplied with each unit. Other lengths can be ordered per the information below. The cable glands supplied with the unit must be replaced with suitable fittings when installing conduit. Specific length cable Part Number 2924-103 Specify length and units 1000 ft. (305m) reel Part Number 2924-102 (reel is non-returnable) Order cable by the part numbers listed below. Series 660 Switching Combinations Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Fixed Differential Form 1100 (12.15) ©SOR Inc. SORInc.com Fixed Differential | 913-888-2630 | Registered Quality System to ISO 9001 11/28 RF Capacitance Level Controls RF Transmitter 670 RF Transmitter The 670 provides continuous level measurement and a 4-20 mA linear output. It is a high-performance, general-purpose level transmitter that is well suited for many demanding applications that other technologies cannot handle. Features FM Approved, CSA Certified hazardous locations Easy calibration Electrostatic discharge protection up to 4000 volts Resists process media coating Product Specifications Input Power 12-55 VDC 12-30VDC for Intrinsically Safe Output Type 4-20 mA Loop Resistance 600 ohms maximum @ 24 VDC Zero Range 0 to 500 pF Span Range 50 to 2000 pF Accuracy +1.0% of span Linearity +0.5% of full scale Sensitivity Repeatability Response Time 12/28 0.5 pF +0.5% of full scale 0.1 second Registered Quality System to ISO 9001 Enclosure Environmental Rating Electrostatic Discharge Protection Conduit Connection NEMA 4X; IP65 4000 volts 3/4” NPT Maximum Remote Distance from Sensor 10 ft. (3m) Ambient Temperature Range -40 to 160oF (-40 to 71oC) Process Temperature Range Probe Dependent Maximum Process Pressure Probe Dependent Weight | 913-888-2630 | SORInc.com 2.5 lbs. (1.2 kg) plus 2 lbs. (1 kg) for remote Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls How to Order The 670 consists of two parts. The first is the electronics and housing. The second is the probe. For probe types and model numbers, see pages 21-25. Model Number System 670 R 9-BKPK 670 RF Transmitter with loop-powered remote housing, flat-surface mounting bracket and pipe mounting kit. 2 Accessories & Certificates Al CSA Intrinsically Safe* BK Remote electronics flat surface mounting bracket (R housing only) 1 CS CSA Explosion Proof* FI FM Intrinsically Safe* Integral Housing K FM FM Explosion Proof* Remote housing - 10 feet (3m) maximum 1010 R PK Pipe mounting kit - BK accessory required (R housing only) Order remote cable as 670-XX-S XX= cable length in feet PP Fiber tag with customer-specified information PY Powder Coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) RR SS nameplate permanently affixed to housing with customer-specified information TT SS nameplate permanently affixed to housing VV Fungicidal varnish applied to housing exterior YY Epoxy coating applied to housing exterior (200 hours-salt spray) C1 C3 C4 C6 Individual Certificates Certificate of Calibration Inspection Compliance/Conformance Insulation Resistance Electrical Housing *Electronics and probe must have the same agency to maintain the listing integrity (i.e. CS or AI electronics with CS probe, or FM or FI electronics with FM probe). 670 R 9 BK PK Model Number Agency Approval Agency Safety Method Approval Model(s) FM Explosion Proof Intrinsically Safe CSA Explosion Proof Intrinsically Safe Class I, Groups C, D Class II, Groups E, F, G Class III, Division 1 Class I, Groups A, B, C, D Class II, Groups E, F, G Class III, Division 1 Class I, Groups C, D Class II, Groups E, F, G Class III, Division 1 Class I, Groups A, B, C, D Class II, Groups E, F, G Class III, Division 1 670x9-FM Form 1100 (12.15) ©SOR Inc. SORInc.com 670x9-FI 670x9-CS 670x9-AI | 913-888-2630 | Registered Quality System to ISO 9001 13/28 RF Capacitance Level Controls Housing: K for Model 651 Dimensions in this catalog are for reference only. They may be changed without notice. Contact MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # the factory for certified drawings for a particular model number. Dimensions in this catalog are PROCESS CONNECTION expressed as millimeters over inches. 116.7 (Linear = mm/in.) 4.59 Linear = mm in. MODEL # MODEL # SALES ORDER # SALES ORDER # LINE ITEM # 116.7 4.59 SALES ORDER # 116.7 4.59 96.0 116.7 3.78 4.59 96.0 3.78 96.0 3.78 C 1 STILLING WELL PROCESS CONNECTION SEE TABLE A LENGTH (PER MODEL NUMBER) B 1 PROCESS CONNECTION SEEPROCESS TABLE CONNECTION SEE TABLE INACTIVE SHEATH LENGTH (PER MODEL NUMBER) B 1 1 D Model Name: 0390652.ASSEM/2/0+ (PER MODEL NUMBER) 19.1 0.75 (INACTIVE SHEATH ONLY) D D B 19.1 0.75 (INACTIVE SHEATH ONLY) INACTIVE SHEATH LENGTH (PER MODEL NUMBER) INACTIVE SHEATH LENGTH INACTIVE SHEATH LENGTH (PER MODEL NUMBER) (PER MODEL NUMBER) SENSOR STYLE A LENGTH (PER MODEL A NUMBER) LENGTH BARE 19.1 0.75 19.1 (INACTIVE SHEATH ONLY) 0.75 (INACTIVE SHEATH ONLY) D Model Name: 0390652.ASSEM/2/0+ SHEATH BARE WITH STILLING WELL SHEATH WITH STILLING WELL CABLE INACTIVE SHEATH Model Name: 0390652.ASSEM/2/0+ 14/28 120.0 4.72 N/A 237.5 9.35 ON A FIVE THREAD ENGAGEMENT. C 1 N/A CABLE PROBE 87.8 3.46 99.7 3.92 1 158.5 6.24 ELECTRICAL NOTES: PROCESS CONNECTION B 1 NOTES: CONNECTION 3/4 NPTF 1. DIMENSION APPROXIMATE AND BASED 1 ELECTRICAL SEE TABLE NOTES: ON ABASED FIVE THREAD ENGAGEMENT. CONNECTION 1. DIMENSION APPROXIMATE AND 1 3/4 NPTF ON A FIVE THREAD ENGAGEMENT. 1. DIMENSION APPROXIMATE AND BASED 1 ELECTRICAL CONNECTION 3/4 NPTF C 1 DIM B ALL OTHER CA PROBES PR 94.1 20 3/4 NPTM 3.71 8 97.3 21 1, 1-1/2, & 2 NPTM 1 SALES PAGE 3.83 8 LINE ITEM # PURCHASE ORDER # SALES PAGE 158.5 27 FLANGED PURCHASE ORDER # 6.24 10 DIM B DIM C 1 SALES PAGE 120.0 PROCESS CONNECTION DIM B DIM C LINE ITEM # PURCHASE ORDER # STILLING WELL N/A CABLE N CABLE ALL OTHER ALL OTHER 4.72 PROCESS CONNECTION PROBE ALL OTHER PROBES PROBE PROBES CABLE ALL OTHER CABLE DIM B DIM C PROBE CONNECTION PROBES PROBE PROBES 87.8 94.1 205.2 211.6 PROCESS 3/4 NPTM CABLE OTHER CABLE 3.46 ALL211.6 3.71 8.08 ALL OTHER 8.33 87.8 94.1 205.2 3/4 NPTM PROBE PROBES PROBE 3.46 3.71 8.08 8.33 99.7 97.3 217.2 PROBES 214.8 ELECTRICAL 1, 1-1/2, & 2 NPTM NOTES: 87.8 94.1 205.2 211.6 3.92 3.83 8.55 8.46 CONNECTION 99.73/4 NPTM97.3 217.2 214.8 1, 1-1/2, & 2 NPTM 3.46 3.71 8.08 8.33 3/4 NPTF 3.92 3.83 8.55 8.46 158.5 158.5 276.0BASED 276.0 1. DIMENSION APPROXIMATE AND FLANGED1 99.7 97.3 217.2 214.8 6.24ENGAGEMENT. 10.87 10.87 ON6.24 A FIVE THREAD 1, 1-1/2, & 2 NPTM 158.5 158.5 276.0 276.0 3.92 3.83 8.55 8.46 FLANGED 6.24 6.24 10.87 10.87 120.0 237.5 STILLING WELL N/A N/A 158.5 158.5 276.0 276.0 4.72 9.35 FLANGED120.0 237.5 6.24 6.24 10.87 10.87 STILLING WELL N/A N/A 4.72 9.35 96.0 3.78 Drawing 0390652 GTH NUMBER) + Dimensions Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com ISO-9001 SENSOR STYLE D 14685 W 105TH 91 SO PRODUCT CERTIFICATION DRA ALL DIMENSIONS ARE ±1/1 UNLESS OTHERWISE SPECI 12.7 BARE MM 0.50 LINEAR = IN 15.9 SHEATH 0.63 DRAWING KS IS THE EXCLUS 14685 W 105THTHIS ST LENEXA, 66215 U NO USE WHATSOEVER OF THE IN BARE WITH 26.7 913-888-2630 HEREON, NOR REPRODUCTION IN 14685STILLING W 105TH ST LENEXA, KS 66215 USA SORINC.COM WELL 1.05 14685 W 105TH ST LENEXA, KS 66215 USA MADE WITHOUT THE EXPRESS WRI ISO-9001 913-888-2630 913-888-2630 DRAWN BY TITLE SHEATHSORINC.COM WITH 26.7 SORINC.COM ISO-9001 ISO-9001 K MITCHELL DIMENSION DRAWING RF PROB STILLING 1.05 DRAWN BY SENSOR STYLE D WELLPRODUCT DRAWN BY CERTIFICATION DRAWING CHECKED BY MODEL 651 (K HOUSING CONFI K DIMENSIONS MITCHELL ALL 7.90 ARE ±1/16 IN K MITCHELL D SENSOR M SMITH PRODUCT DRAWING DRAWIN STYLECERTIFICATION D PRODUCT CERTIFICATION DRAWING CABLE CHECKED BY UNLESS OTHERWISE SPECIFIED CHECKED BY EO NUMBER: 5200 12.7 ENGINEER APPROVAL 0.31ARE ±1/16 ALL DIMENSIONS ARE ±1/16 IN ALL DIMENSIONS IN BARE MM M SMITH M SMITH 0.50 LINEAR = UNLESS OTHERWISE SPECIFIED UNLESS S BOAL 12.7 OTHERWISE SPECIFIED 12.7 SCALE: 0.65 ENGINEER15.9 APPROVAL IN ENGINEER APPROVAL BARE DATE MM SHEATH MM INACTIVE SH 0.50 15.9 LINEAR =0.50 LINEAR = S BOAL S PRINT BOAL DO NOT SCALE 0.63 IN IN SHEATH 07 MAR 201 DATE DATE 0.63 15.9 15.9 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. SHEATH 07 MAR 2013 07 MAR 2013 0.63 0.63 NO USE WHATSOEVER OF THE INFORMATION CONTAINED BARE WITH 26.7 THIS DRAWING THE EXCLUSIVE PROPERTY THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. HEREON, NORISREPRODUCTION IN WHOLEOF ORSOR. PART MAY BE WELL NOMADE USE WHATSOEVER OF EXPRESS THE INFORMATION CONTAINED OF SOR. BARE WITH NO USE WHATSOEVER26.7 OF1.05 THE INFORMATION CONTAINED WITHOUT THE WRITTEN PERMISSION 26.7 STILLING HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE WELL 1.05 1.05 STILLING MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE SHEATH WITH 26.7 MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. WITH 26.7 STILLING WELL 1.05 TITLE DIMENSION DRAWING RF PROBE TITLE 26.7 SHEATH MODEL 651 (K HOUSING CONFIGURATION) DRAWING RF PROBE WELLDRAWING1.05 DIMENSION RF7.90 PROBEDIMENSION 1.05 STILLING DRAWING NUMBER REV MODEL 651 (K HOUSING CABLE EO NUMBER: 5200 CONFIGURATION) MODEL 651 (K HOUSING CONFIGURATION) 7.90 0.31 DRAWING NUMBER 7.90 CABLE 0390652 REV 3 NUMBER: 5200 DRAWING EO NUMBER REV EO NUMBER: 5200 0.31 SCALE: 0.65 0390652 3 DWG S 0.31 15.9 0390652 3 INACTIVE SHEATH SHEET 1 OF 2 SCALE: 0.65 DWG SIZE 15.9 DO NOT SCALE PRINT 0.63 SCALE: 0.65 B INACTIVE SHEATH DWG SIZE 15.9 SHEET 1 OF 2 0.63 SHEET 1DO NOT B OFSCALE2 PRINT DO NOT SCALE PRINT 0.63 B Reset Fo Reset Form Reset Form Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls Dimensions Housing: K for Model 651 Drawing 0390652 2 SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # D 36.5 1.44 3/4-16 UNF-2B X 31.8 1.25 11.1 0.44 22.2 0.88 DETAIL A SCALE 1.5 DUAL RIGID PROBE DETAIL 50.8 2.00 28.4 1.12 Linear = mm in. MINIMUM CLEARANCE HOLE FOR INSTALLATION 54.9 2.16 ISO-9001 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN SEE DETAIL A K MITCHELL CHECKED BY M SMITH ENGINEER APPROVAL S BOAL DATE 07 MAR 2013 27.0 1.06 DUAL CABLE PROBE DETAIL 31.8 1.25 54.0 2.13 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE DIMENSION DRAWING RF PROBE MODEL 651 (K HOUSING CONFIGURATION) EO NUMBER: 5200 SCALE: 0.50 DO NOT SCALE PRINT DRAWING NUMBER Model Name: 0390652.ASSEM/2/0+ Form 1100 (12.15) ©SOR Inc. REV 0390652 3 SHEET 2 OF 2 DWG SIZE B Reset Form SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 15/28 RF Capacitance Level Controls Dimensions Housing: R for Model 670 & 681 Drawing 0390653 1 SALES PAGE MODEL # SALES ORDER # SENSOR STYLE BARE SHEATH BARE WITH STILLING WELL SHEATH WITH STILLING WELL CABLE INACTIVE SHEATH LINE ITEM # PURCHASE ORDER # DIM B DIM D 1 DIM C PROCESS CONNECTION NOTES: 12.7 0.50 15.9 0.63 26.7 1.05 26.7 1.05 7.9 0.31 15.9 0.63 1. DIMENSION APPROXIMATE AND BASED ON A FIVE THREAD ENGAGEMENT. 3/4 NPTM 1, 1-1/2, & 2 NPTM Linear = mm in. FLANGED STILLING WELL CABLE ALL OTHER CABLE ALL OTHER 87.8 3.46 99.7 3.92 158.5 6.24 94.1 3.71 97.3 3.83 158.5 6.24 120.0 4.72 152.9 6.02 164.8 6.49 223.7 8.81 159.2 6.27 162.4 6.39 223.7 8.81 185.1 7.29 N/A N/A 118.6 4.67 96.0 3.78 116.7 4.59 3/4 NPTF ELECTRICAL CONNECTION C 1 PROCESS CONNECTION SEE TABLE 213.5 8.41 1 B ISO-9001 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM DRAWN BY 45.2 1.78 INACTIVE SHEATH LENGTH (PER MODEL NUMBER) A LENGTH (PER MODEL NUMBER) CHECKED BY M SMITH ENGINEER APPROVAL S BOAL DATE 07 MAR 2013 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. 19.1 0.75 (INACTIVE SHEATH ONLY) 96.0 3.78 2X 3/4 NPTF K MITCHELL PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN TITLE DIMENSION DRAWING RF PROBE MODEL 670 & 681 (R HOUSING CONFIGURATION) D ELECTRONICS HOUSING DRAWING NUMBER EO NUMBER: 5200 SENSOR REV 0390653 SCALE: 0.50 2 SHEET 1 OF 2 DO NOT SCALE PRINT Model Name: 0390653.ASSEM/2/3+ DWG SIZE B Reset Form 2 SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # D 36.5 1.44 3/4-16 UNF-2B X DUAL RIGID PROBE DETAIL 31.8 1.25 50.8 2.00 11.1 0.44 22.2 0.88 DETAIL A SCALE 1.5 28.4 1.12 MINIMUM CLEARANCE HOLE FOR INSTALLATION 54.9 2.16 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 DRAWN BY SEE DETAIL A PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN K MITCHELL CHECKED BY M SMITH ENGINEER APPROVAL S BOAL DATE 07 MAR 2013 DUAL CABLE PROBE DETAIL 27.0 1.06 31.8 1.25 54.0 2.13 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE EO NUMBER: 5200 SCALE: 0.50 DO NOT SCALE PRINT Model Name: 0390653.ASSEM/2/3+ 16/28 Registered Quality System to ISO 9001 Linear = mm in. DIMENSION DRAWING RF PROBE MODEL 670 & 681 (R HOUSING CONFIGURATION) DRAWING NUMBER REV 0390653 2 Drawing 0390653 SHEET 2 OF 2 DWG SIZE B Reset Form | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls MODEL # SALES ORDER # 116.7 Housing: K for Model 670 & 681 4.59 96.0 (RF Probe Model 651-K9) 3.78 Drawing 0390654 MODEL # MODEL # Linear = mm in. SALES ORDER # SALES ORDER # 116.7 4.59 1 1 96.0 3.78 96.0 3.78 1 LINE ITEM # 116.7 4.59 C C PURCHASE ORDER # DIM B PROCESS CONNECTION ALL OTHER CABLE PROBES PROBE 256.0 1 94.1 3/4 NPTM 3.71 10.08 LINE ITEM # PURCHASE ORDER # SALES PAGE 97.3 268.0 PURCHASE ORDER # 1, 1-1/2, DIM B & 2 NPTM 3.83 10.55 PROCESS CONNECTION DIM B DIM C 158.5 158.5 326.8 CABLE ALL OTHER CABLE ALL OTHER FLANGED PROCESS CONNECTION 6.24 12.87 PROBES PROBES 6.24 CABLE ALLPROBE OTHER CABLE ALLPROBE OTHER 120.0 87.8 94.1 WELL PROBES 256.0 PROBES PROBE STILLING N/A262.4 N/A 3/4 NPTMPROBE 4.72 3.46 3.71 10.08 10.33 87.8 94.1 256.0 262.4 3/4 NPTM 99.7 97.3 268.0 265.6 3.46 3.71 10.08 10.33 1, 1-1/2, & 2 NPTM 3.92 3.83 10.55 10.46 99.7 97.3 268.0 265.6 1, 1-1/2, & 2 NPTM 158.5 158.5 326.8 326.8 3.83 10.55 10.46 FLANGED 3.92 6.24 6.24 12.87 12.87 158.5 326.8 326.8 158.5 FLANGED 120.0 288.3 6.24 6.24 12.87 12.87 STILLING WELL N/A N/A 4.72 11.35 120.0 288.3 STILLING WELL N/A N/A NOTES: 4.72 11.35 3/4 NPTF ELECTRICAL CONNECTION 1. DIMENSION APPROXIMATE AND BASED 1 ON A FIVE THREAD ENGAGEMENT. 3/4 NPTF ELECTRICAL CONNECTION 3/4 NPTF ELECTRICAL CONNECTION PROCESS CONNECTION SEE TABLE C Dimensions LINE ITEM # CABLE PROBE 87.8 SALES PAGE 3.46 1 99.7 DIM C 3.92 NOTES: 1 1B NOTES: 1. DIMENSION APPROXIMATE AND BASED 1 ON A FIVE THREAD 1. DIMENSION APPROXIMATE AND ENGAGEMENT. BASED ON A FIVE THREAD ENGAGEMENT. ISO-9001 PROCESS CONNECTION PROCESS B 1 CONNECTIONSEE TABLE SENSOR STYLE INACTIVE SHEATH LENGTH (PER MODEL NUMBER) B 1 D 14685 W 105TH ST LE 913-88 SORIN PRODUCT CERTIFICATION DRAWIN ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED 12.7 MM 0.50 LINEAR = 14685 W 105TH ST LENEXA, KS 66215 USA IN SEE TABLE 913-888-2630 15.9USA 14685 W 105TH ST LENEXA, KS 66215 SORINC.COM SHEATH ISO-9001 A LENGTH 0.63 913-888-2630 THIS DRAWING IS THE EXCLUSIVE PR DRAWN BY (PER MODEL NUMBER) SORINC.COM ISO-9001 NO USE WHATSOEVER OF THE INFORM BARE WITH 26.7 K MITCHELL HEREON, NOR REPRODUCTION IN WHO SENSOR STYLE D BY 19.1 LENGTH INACTIVE SHEATH PRODUCT CERTIFICATION DRAWING STILLING WELL DRAWN 1.05 CHECKED BY MADE WITHOUT THE EXPRESS WRITTEN ALL DIMENSIONS AREK±1/16 IN MITCHELL 0.75NUMBER) (PERLENGTH MODEL M SMITH SENSOR STYLE D INACTIVE SHEATH PRODUCT TITLE SHEATH WITH CHECKED 26.7 UNLESSDRAWING OTHERWISE SPECIFIED BY 12.7 CERTIFICATION ENGINEER APPROVAL (INACTIVE SHEATH ONLY) BARE ALL DIMENSIONSSTILLING ARE ±1/16WELL IN MM (PER MODEL NUMBER) DIMENSION DRAWING RF PROBE MO 1.05 0.50 OTHERWISE SPECIFIED LINEAR = M SMITH S BOAL UNLESS 12.7 INENGINEER APPROVAL 670, & 681 (K HOUSING CONFIGURA BARE DATE 7.90 15.9 LINEAR = MMCABLE 0.50 DRAWING NUM S BOAL SHEATH EO MAR NUMBER: 07 2013 5200 IN 0.31 A LENGTH 0.63 DATE 03 15.9 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. (PER MODEL NUMBER) SHEATH D SCALE: 0.56 07 MAR 2013 CONTAINED 15.9 A LENGTH NO USE WHATSOEVER OF THE INFORMATION BARE WITH 26.7 0.63 INACTIVE SHEET HEREON, NORSHEATH REPRODUCTION IN 0.63 WHOLE OR PART MAY BE THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. 19.1 DO NOT SCALE PRINT (PER MODEL NUMBER) WELL 1.05 MADE THE EXPRESS WRITTEN PERMISSION OF SOR. NO USE WHATSOEVER OF WITHOUT THE INFORMATION CONTAINED BARE WITHSTILLING26.7 0.75 Model Name: 0390654.ASSEM/2/3+ HEREON, NOR TITLE REPRODUCTION IN WHOLE OR PART MAY BE 19.1 SHEATH 1.05 WITH 26.7 STILLING WELL MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. (INACTIVE SHEATH ONLY) 0.75 DIMENSION DRAWING RF PROBE MODEL 651-K9 STILLING WELL 1.05 TITLE SHEATH WITH 26.7 670, & 681 (K HOUSING CONFIGURATION) (INACTIVE SHEATH ONLY) 7.90 DRAWING RF PROBE MODEL 651-K9 DIMENSION STILLING WELL CABLE 1.05 DRAWING NUMBER REV EO NUMBER: 5200 670, & 681 (K HOUSING CONFIGURATION) 0.31 7.90 0390654 2 DRAWING NUMBER REV CABLE EO NUMBER: D SCALE: 0.56 DWG SIZE 15.9 5200 0.31 INACTIVE SHEATH 0390654 SHEET 21 OF 2 DO NOT SCALE PRINT 0.63 B D SCALE: 0.56 DWG SIZE 15.9 PAGE2 2 INACTIVE SHEATH Model Name: 0390654.ASSEM/2/3+ SHEET SALES 1 OF DO NOT SCALE PRINT 0.63 B MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # Reset Form BARE Model Name: 0390654.ASSEM/2/3+ Reset Form D 36.5 1.44 3/4-16 UNF-2B X 31.8 1.25 11.1 0.44 DUAL RIGID PROBE DETAIL 22.2 0.88 DETAIL A SCALE 1.5 28.4 1.12 50.8 2.00 MINIMUM CLEARANCE HOLE FOR INSTALLATION 54.9 2.16 ISO-9001 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM DRAWN BY SEE DETAIL A PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN K MITCHELL CHECKED BY M SMITH ENGINEER APPROVAL S BOAL DATE 07 MAR 2013 DUAL CABLE PROBE DETAIL 27.0 1.06 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE DIMENSION DRAWING RF PROBE MODEL 651-K9 670, & 681 (K HOUSING CONFIGURATION) 54.0 2.13 EO NUMBER: 5200 SCALE: 0.50 DO NOT SCALE PRINT Model Name: 0390654.ASSEM/2/3+ Form 1100 (12.15) ©SOR Inc. Linear = mm in. 31.8 1.25 DRAWING NUMBER REV 0390654 2 SHEET 2 OF 2 DWG SIZE B Reset Form SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 17/28 RF Capacitance Level Controls Dimensions Housing: W for Model 66X 1 SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # NOTES: 329.4 12.97 273.1 10.75 155.6 6.13 1. DIMENSION APPROXIMATE AND BASED ON A FIVE THREAD ENGAGEMENT. 1 139.7 5.50 69.9 2.75 209.6 8.25 120.7 4.75 2X 3/4 NPTF ELECTRICAL CONNECTION 60.3 2.38 251.1 9.89 152.4 6.00 44.5 1.75 148.3 5.84 1 D 1 2X 1/4 MOUNTING HOLES C 1 B PROCESS CONNECTION SEE TABLE Linear = mm in. 2X 3/4 NPTF ELECTRICAL CONNECTION INACTIVE SHEATH LENGTH (PER MODEL NUMBER) A LENGTH (PER MODEL NUMBER) ISO-9001 DRAWN BY Drawing 0390655 PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN 19.1 0.75 (INACTIVE SHEATH ONLY) 176.3 6.94 92.1 3.63 4X CHECKED BY M SMITH ENGINEER APPROVAL S BOAL DATE THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. E SENSOR 88.9 3.50 K MITCHELL 07 MAR 2013 88.9 3.50 ELECTRONICS HOUSING SCALE 0.38 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM TITLE DIMENSION DRAWING RF PROBE MODEL 66X (W HOUSING CONFIGURATION) DRAWING NUMBER EO NUMBER: 5200 7.9 MOUNTING HOLES 0.31 REV 0390655 SCALE: 0.50 2 DWG SIZE SHEET 1 OF 2 DO NOT SCALE PRINT Model Name: 0390655.ASSEM/1/2+ B Reset Form 2 SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # DIM B PROCESS CONNECTION 3/4 NPTM 1, 1-1/2, & 2 NPTM FLANGED CABLE PROBE 113.2 4.46 125.1 4.92 183.9 7.24 STILLING WELL N/A DIM C ALL OTHER PROBES 119.5 4.71 122.7 7.83 183.9 7.24 145.4 5.72 CABLE PROBE 157.6 6.21 169.5 6.67 228.4 8.99 N/A DIM E ALL OTHER PROBES 164.0 6.46 167.1 6.58 228.4 8.99 189.8 7.47 CABLE PROBE 174.7 6.88 186.6 7.35 245.5 9.66 N/A ALL OTHER PROBES 181.0 7.13 184.2 7.25 245.5 9.66 206.9 8.15 SENSOR STYLE D 12.7 0.50 15.9 0.63 26.7 1.05 26.7 1.05 7.90 0.31 15.9 0.63 BARE SHEATH 31.8 1.25 50.8 2.00 BARE WITH STILLING WELL SHEATH WITH STILLING WELL DUAL RIGID PROBE DETAIL 28.4 1.12 D CABLE MINIMUM CLEARANCE HOLE FOR INSTALLATION 54.9 2.16 SEE DETAIL A INACITIVE SHEATH 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ISO-9001 DRAWN BY 36.5 1.44 27.0 1.06 PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN 11.1 0.44 22.2 0.88 DETAIL A SCALE 1.5 54.0 2.13 DUAL CABLE PROBE DETAIL 18/28 Registered Quality System to ISO 9001 M SMITH ENGINEER APPROVAL S BOAL DATE 07 MAR 2013 TITLE DIMENSION DRAWING RF PROBE MODEL 66X (W HOUSING CONFIGURATION) EO NUMBER: 5200 SCALE: 0.50 DO NOT SCALE PRINT Model Name: 0390655.ASSEM/1/2+ CHECKED BY THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. 31.8 1.25 3/4-16 UNF-2B X K MITCHELL DRAWING NUMBER REV 0390655 = mm2 Linear SHEET 2 OF 2 in. B DWG SIZE Reset Form Drawing 0390655 | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls MODEL # SALES ORDER # Housing: J for Model 66X MODEL MODEL# # Drawing 0390656 SALES SALESORDER ORDER# # Linear = mm in. Dimensions LINE ITEM # PURCHASE ORDER # DIM B 180.9 7.12 PROCESS CONNECTION LINE LINEITEM ITEM# # CABLE PROBE SALES SALESPAGE PAGE 1 1 72.3 3/4 NPTM 2.85 84.2 DIM DIMB B DIM DIM C C 1, 1-1/2, & 2 NPTM 3.31 CABLE CABLE ALL ALLOTHER OTHER CABLE CABLE ALL ALLOTHER OTHER 143.0 PROBE PROBE PROBES PROBES FLANGED PROBE PROBE PROBES PROBES 5.63 72.3 72.3 78.6 78.6 299.3 299.3 305.6 305.6 WELL 12.03 2.85 2.85 3.10 3.10 STILLING 11.78 11.78 12.03 N/A 101.6 4.00 PURCHASE PURCHASEORDER ORDER# # 180.9 180.9 7.12 7.12 PROCESS PROCESSCONNECTION CONNECTION 101.6 101.6 4.00 4.00 3/4 3/4NPTM NPTM 84.2 84.2 3.31 3.31 143.0 143.0 5.63 5.63 1,1,1-1/2, 1-1/2,&&2 2NPTM NPTM FLANGED FLANGED STILLING STILLINGWELL WELL 1 81.8 81.8 3.22 3.22 183.9 183.9 7.24 7.24 104.5 104.5 4.11 4.11 N/A N/A 311.2 311.2 12.25 12.25 370.1 370.1 14.57 14.57 308.8 308.8 12.16 12.16 370.1 370.1 14.57 14.57 331.5 331.5 13.05 13.05 N/A N/A CC 1.1.DIMENSION DIMENSIONAPPROXIMATE APPROXIMATEAND ANDBASED BASED ON ONAAFIVE FIVETHREAD THREADENGAGEMENT. ENGAGEMENT. 11 ELECTRICAL ELECTRICALCONNECTION CONNECTION 1 1NPTF NPTFSTANDARD STANDARD 3/4 3/4NPTF NPTFOPTIONAL OPTIONAL PROCESS CONNECTION SEE TABLE 1 B ISO-9001 SENSOR STYLE PROCESS PROCESS CONNECTION CONNECTION SEE SEETABLE TABLE 11 A LENGTH (PER MODEL NUMBER) 19.1 19.1 0.75 0.75 (INACTIVE (INACTIVESHEATH SHEATHONLY) ONLY) BB INACTIVE SHEATH LENGTH (PER MODEL NUMBER) SENSOR SENSORSTYLE STYLE SHEATH SHEATH BARE BAREWITH WITH STILLING STILLINGWELL WELL SHEATH SHEATHWITH WITH STEALING STEALINGWELL WELL D CABLE CABLE DD MODEL Model Model Name: Name: 0390656.ASSEM/1/4 0390656.ASSEM/1/4 # INACTIVE INACTIVESHEATH SHEATH SALES ORDER # D LINE ITEM # ISO-9001 ISO-9001 DD 12.7 12.7 0.50 0.50 15.9 15.9 0.63 0.63 26.7 26.7 1.05 1.05 26.7 26.7 1.05 1.05 7.90 7.90 0.31 0.31 15.9 15.9 0.63 0.63 BARE 14685 14685 WW 105TH 105TH STST LENEXA, LENEXA, KSKS 66215 66215USA USA 0.50 913-888-2630 913-888-2630 SORINC.COM SORINC.COM 15.9 SHEATH 14685 W 105TH ST LEN 913-888 SORINC PRODUCT CERTIFICATION DRAWIN ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN 12.7 19.1 0.75 BARE BARE (INACTIVE SHEATH ONLY) INACTIVE INACTIVESHEATH SHEATHLENGTH LENGTH (PER (PERMODEL MODELNUMBER) NUMBER) Model Name: 0390656.ASSEM/1/4 0.63 DRAWN DRAWN BY BY THIS DRAWING IS THE EXCLUSIVE PRO K KMITCHELL MITCHELL NO USE WHATSOEVER OF THE INFORMA BAREDRAWING WITH 26.7 PRODUCT PRODUCTCERTIFICATION CERTIFICATION DRAWING CHECKED CHECKED BY BY HEREON, NOR REPRODUCTION IN WHOL STILLING WELL 1.05 ALL ALLDIMENSIONS DIMENSIONS ARE ARE ±1/16 ±1/16 ININ MADE WITHOUT THE EXPRESS WRITTEN P MMSMITH SMITH UNLESS UNLESSOTHERWISE OTHERWISESPECIFIED SPECIFIED ENGINEER ENGINEER APPROVAL APPROVAL TITLE SHEATH WITH 26.7 MM MM LINEAR LINEAR == BOAL DIMENSION DRAWING RF PROBE STEALING WELL S SBOAL 1.05 ININ DATE DATE MODEL 66X (J HOUSING CONFIGURAT 7.90 0808MAR MAR2013 2013 DRAWING NUMBE CABLE EO NUMBER: 5200 0.31 THIS THIS DRAWING DRAWING IS IS THE THE EXCLUSIVE EXCLUSIVE PROPERTY PROPERTY OFOF SOR. SOR. 039 NONO USE USE WHATSOEVER WHATSOEVER OFOF THE THE INFORMATION INFORMATION CONTAINED CONTAINED SCALE: 0.50 15.9 HEREON, HEREON, NOR NOR REPRODUCTION REPRODUCTION IN IN WHOLE WHOLE OROR PART PART MAY MAY BEBE INACTIVE SHEATH SHEET MADE MADE WITHOUT WITHOUT THE THE EXPRESS EXPRESS WRITTEN WRITTEN PERMISSION PERMISSION OFOF SOR. SOR. 0.63 DO NOT SCALE PRINT TITLE TITLE DIMENSION DIMENSIONDRAWING DRAWINGRFRFPROBE PROBE MODEL MODEL66X 66X(J (JHOUSING HOUSINGCONFIGURATION) CONFIGURATION) EOEONUMBER: NUMBER:5200 5200 DRAWING DRAWING NUMBER NUMBER REVREV 0390656 0390656 SCALE: SCALE:0.50 0.50 22 DWG DWG SIZE SIZE SHEET SHEET 1 1 OFOF SALES 2 2 PAGE BB DODO NOT NOT SCALE SCALE PRINT PRINT PURCHASE ORDER # 2 Reset ResetForm Form D 36.5 1.44 3/4-16 UNF-2B X DUAL RIGID PROBE DETAIL 31.8 1.25 50.8 2.00 11.1 0.44 22.2 0.88 28.4 1.12 DETAIL A SCALE 1.5 MINIMUM CLEARANCE HOLE FOR INSTALLATION 54.9 2.16 SEE DETAIL A ISO-9001 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM DRAWN BY PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN K MITCHELL CHECKED BY M SMITH ENGINEER APPROVAL S BOAL DATE 08 MAR 2013 31.8 1.25 54.0 2.13 DUAL CABLE PROBE DETAIL 27.0 1.06 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE Model Name: 0390656.ASSEM/1/4 Linear = mm in. DIMENSION DRAWING RF PROBE MODEL 66X (J HOUSING CONFIGURATION) EO NUMBER: 5200 SCALE: 0.50 DRAWING NUMBER 0390656 SHEET 2 OF 2 Drawing 0390656 DO NOT SCALE PRINT Form 1100 (12.15) ©SOR Inc. N/A 1. DIMENSION APPROXIMATE AND BASED ON A FIVE THREAD ENGAGEMENT. ELECTRICAL CONNECTION 1 NPTF STANDARD 3/4 NPTF OPTIONAL NOTES: NOTES: AALENGTH LENGTH (PER (PERMODEL MODELNUMBER) NUMBER) CABLE PROBE 299.3 11.78 311.2 12.25 370.1 14.57 NOTES: C 1 11 ALL OTHER PROBES 78.6 3.10 81.8 3.22 183.9 7.24 104.5 4.11 REV 2 DWG SIZE B Reset Form SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 19/28 RF Capacitance Level Controls Dimensions Housing: R for Model 66X Drawing 0390657 1 SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # 118.6 4.67 96.0 3.78 3/4 NPTF ELECTRICAL CONNECTION C 1 PROCESS CONNECTION SEE TABLE 1 NPTF STANDARD 3/4 NPTF OPTIONAL ELECTRICAL CONNECTION B 1 Linear = mm in. INACTIVE SHEATH LENGTH PER MODEL NUMBER 19.1 0.75 INACTIVE SHEATH ONLY A LENGTH PER MODEL NUMBER 3/4 NPTF ELECTRICAL CONNECTION DIMENSION APPROXIMATE AND BASED ON A FIVE THREAD ENGAGEMENT 1 D 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM ELECTRONICS HOUSING SENSOR ISO-9001 DRAWN BY SENSOR STYLE DIM B PROCESS CONNECTION 3/4 NPT (M) 1, 1-1/2, & 2 NPT (M) FLANGED CABLE PROBE 87.8 3.46 99.7 3.92 158.5 6.24 STILLING WELL N/A ALL OTHER PROBES 94.1 3.71 97.3 3.83 158.5 6.24 120.0 4.72 DIM C CABLE PROBE 152.9 6.02 164.8 6.49 223.7 8.81 N/A BARE ALL OTHER PROBES 159.2 6.27 162.4 6.39 223.7 8.81 185.1 7.29 SHEATH BARE WITH STILLING WELL SHEATH WITH STILLING WELL CABLE INACTIVE SHEATH D PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN 12.7 0.50 15.9 0.63 26.7 1.05 26.7 1.05 7.90 0.31 15.9 0.63 K MITCHELL CHECKED BY M SMITH ENGINEER APPROVAL S BOAL DATE 08 MAR 2013 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE DIMENSION DRAWING RF PROBE MODEL 66X (R HOUSING CONFIGURATION) DRAWING NUMBER EO NUMBER: 5200 REV 0390657 SCALE: 0.50 3 SHEET 1 OF 2 DO NOT SCALE PRINT Model Name: 0390653.ASSEM/2/3+ B Reset Form 2 SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # D 36.5 1.44 3/4-16 UNF-2B X 31.8 1.25 50.8 2.00 DUAL RIGID PROBE DETAIL 11.1 0.44 28.4 1.12 22.2 0.88 DETAIL A SCALE 1.5 MINIMUM CLEARANCE HOLE FOR INSTALLATION 54.9 2.16 ISO-9001 14685 W 105TH ST LENEXA, KS 66215 USA 913-888-2630 SORINC.COM DRAWN BY SEE DETAIL A PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN K MITCHELL CHECKED BY Linear = mm in. M SMITH ENGINEER APPROVAL S BOAL DATE 08 MAR 2013 31.8 1.25 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. 27.0 1.06 54.0 2.13 DUAL CABLE PROBE DETAIL TITLE DIMENSION DRAWING RF PROBE MODEL 66X (R HOUSING CONFIGURATION) EO NUMBER: 5200 SCALE: 0.50 DO NOT SCALE PRINT Model Name: 0390653.ASSEM/2/3+ DRAWING NUMBER REV 0390657 3 SHEET 2 OF 2 DWG SIZE B Reset Form Drawing 0390657 20/28 DWG SIZE Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls RF Probes Selection Guidelines Selecting the right probe for your application is very important. The objective is to maximize the amount of capacitance change for every inch (cm) of level change. Following are general guidelines for selecting a probe for a particular application. Please consult with SOR or your local SOR sales representative for additional and/or specific information. ® 1. If process media is non-conductive - less than 10µ Siemens/low dielectric (less than 10), select a bare probe. If there is any water in the process, go to number 2. 2. If process media is conductive - greater than 10µ Siemens/high dielectric (greater than 10), select an insulated probe. 3. If process is non-conductive and in a horizontal (bullet) tank, or if the probe must be mounted more than 12 inches from the vessel wall, select a stilling well, dual-rod or dual-cable probe. 4. If vessel is non-metallic, select a stilling well, dual-rod or dual-cable probe. 5. Use rigid probes for measurement lengths of 10 feet or less. Use cable probes for longer ranges. 6. For agency-listed controls, a matching agency listing must be specific on the probe. Available probe agency listings are provided in the following charts and specification pages. Flexible Probes Model Number Probe Material Sensor Diameter Spanned Capacitance in Water Process Temperature Limits Shipping Weight CN Kynar Sheath 5/16” (7.9 mm) 25pF/in. -50 to 180oF (-45 to 82oC) 0.5 lbs. (0.2 kg) +0.2 lb. (0.9 kg) per foot of probe Model Number Probe Material Sensor Diameter Spanned Capacitance in Water Process Temperature Limits Shipping Weight CP Kynar Sheath 5/16” (7.9 mm) 25pF/in. -50 to 180oF (-45 to 82oC) 11 lbs. (5.0 kg) +0.5 lb. (0.2 kg) per foot of probe Single Flexible Probe (non-adjustable) Dual Flexible Probe (non-adjustable) Form 1100 (12.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 21/28 RF Capacitance Level Controls RF Probes Rigid Probes - Sheathed Model Number Probe Material Sensor Diameter Spanned Capacitance in Water Process Temperature Limits Weight CB Teflon® sheath 5/8” (15.9 mm”) 10 pF/in. -100 to 400oF (-73 to 204oC) 1 lbs. (0.5 kg) +0.7 lb. (0.3 kg) per foot of probe Model Number Probe Material Sensor Diameter Spanned Capacitance in Water Process Temperature Limits Weight CC Teflon® sheath inside 316SS stilling well 1.05” (26.7 mm”) 12 pF/in. -100 to 400oF (-73 to 204oC) 2 lbs. (0.9 kg) +1.5 lb. (0.7 kg) per foot of probe Single Rigid Sheath Probe Rigid Sheath Probe with Stilling Well Model Number CD Probe Material Teflon® sheath and 316SS ground probe Sensor Diameter 1/2 & 5/8” (12.7 & 15.9 mm) Spanned Capacitance in Water 10 pF/in. Process Temperature Limits Process Pressure Weight -100 to 400oF (-73 to 204oC) Pressure per CB probe or flange rating, whichever is lower 12 lbs. (5.5 kg) +1.5 lb. (0.7 kg) per foot of probe Rigid Sheath Dual Probe 22/28 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls RF Probes Rigid Probes - Sheathed Model Number Probe Material Sensor Diameter Spanned Capacitance in Water Process Temperature Limits Weight CJ Teflon® sheath 316SS sheath 5/8 & 3/4” (15.9 & 19.1 mm) 10 pF/in. -100 to 400oF (-73 to 204oC) 1 lb. (0.5 kg) +0.7 lb. (0.3 kg) per foot of probe Single Inactive Sheath Probe Rigid Probes - Bare Model Number Probe Material Sensor Diameter Spanned Capacitance in Water Process Temperature Limits Weight CA 316SS 1/2” (12.7 mm) N/A -100 to 400oF (-73 to 204oC) 1 lb. (0.5 kg) +0.7 lb. (0.3 kg) per foot of probe Model Number Probe Material Sensor Diameter Spanned Capacitance in Water Process Temperature Limits Weight CE Bare 316SS probe inside 316SS stilling well 1.05” (26.7 mm”) N/A -100 to 400oF (-73 to 204oC) 2 lbs. (0.9 kg) +1.5 lb. (0.7 kg) per foot of probe Single Rigid Bare Probe Single Rigid Bare Probe with Stilling Well Form 1100 (12.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 23/28 RF Capacitance Level Controls How to Order Model Number System CB C-8A-CS-12-TT Process Connection 3/4” NPT 1” NPT (Required size on CC and CE probes) 1-1/2” NPT 2” NPT 1” 150# ANSI RF Flange 1-1/2” 150# ANSI RF Flange 2” 150# ANSI RF Flange 3” 150# ANSI RF Flange (3C, 3D, 4C, 4D only on CD & CP probes) 4” 150# ANSI RF Flange 1” 300# ANSI RF Flange 1-1/2” 300# ANSI RF Flange 2” 300# ANSI RF Flange 3” 300# ANSI RF Flange 4” 300# ANSI RF Flange 1” Tri-Clamp Sanitary 1-1/2” Tri-Clamp Sanitary 2” Tri-Clamp Sanitary Sensor Material 316SS Standard Polished 316LSS Sensor Style Rigid 316SS Single Probe Rigid Telfon Single Probe Rigid Teflon Single Probe with Stilling Well Rigid Teflon Dual Probe (316SS Ground) Rigid 316SS Single Probe with Stilling Well Rigid Teflon Single Probe with 3/4” OD Inactive Sheath Flexible Kynar Single Probe Flexible Kynar Dual Probe 8A 1A 9A 2A 1C 9C 2C 3C 4 Agency Approval 00 CS FM MB NM No Agency Approvals required CSA (not available on CA, CE)* FM (not available on CA, CE, CN, CP)* IECEX (not available on CA, CE, CJ, CN, CP)* INMETRO (not available on CA, CE, CJ, CN, CP)* *Electronics and probe must have the same agency to maintain the listing integrity (i.e. CS or AI electronics with CS probe, or FM or FI electronics with FM probe). 4C 1D 9D 2D 3D 4D 1T 9T 2T 5 Sensor Length XXX.X Sensor length in inches. Lengths are 5 places including the decimal and leading zeros (see Accessories for different units). Sensor style CJ requires a sensor length followed by an inactive sheath length. See page 19 for limits of probe length. 2 C D 6 FT MK 1 ML CA CB PP CC RR CD TT CE CJ CN CP CB 24/28 3 C Registered Quality System to ISO 9001 8A CS 00012 | 913-888-2630 | SORInc.com Accessories & Certificates Probe length specified in feet (ft.) Probe length specified in meters (m) Probe length specified in centimeters (cm) Fiber tag with customer-specified information SS tag wired on with customerspecified information SS tag riveted on with customerspecified information C2 C8 Individual Certificates Hydrostatic Pressure Test Typical Material of Wetted Parts TT Model Number Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls Agency Safety Method Agency Approval Approval Model(s) FM Explosion Proof Class I, Groups B, C, D Class II, Groups E, F, G Class III, Division 1 CB, CC, CD and CJ CSA Explosion Proof Class I, Groups C, D Class II, Groups E, F, G Class III, Division 1 CB, CC, CD CJ, CN and CP IEC Intrinsically Safe Ex ia IIB T4 CB, CC and CD INMETRO Intrinsically Safe Ex ia IIB T4 CB, CC and CD Probe Insertion Lengths Probe Type Length (inch) Length (cm) Minimum Maximum Minimum Maximum CA 3.5” 234” 8.89 594.4 CB 1.5” 234” 3.81 594.4 CC 2” 234” 5.08 594.4 CD 2” 120” 5.08 304.8 CE 2” 234” 5.08 594.4 CJ 7” 120” 17.78 304.8 Sheath* 1” 114” 2.54 289.6 CN 2” 1440” 5.08 3658 CP 3” 720” 7.62 1829 *Sheath length must be selected with CJ only. Flange Weight and Pressure Rating Process Connection Add to Shipping Weight Maximum Pressure Rating 1C 2 lbs. (1.0 kg) 275 psig (19 bar) 9C 4 lbs. (1.8 kg) 275 psig (19 bar) 2C 5 lbs. (2.3 kg) 275 psig (19 bar) 3C 9 lbs. (4 kg) 275 psig (19 bar) 4C 17 lbs. (8 kg) 275 psig (19 bar) 1D 3 lbs. (1.5 kg) 720 psig (50 bar) 9D 6 lbs. (2.7 kg) 720 psig (50 bar) 2D 8 lbs. (3.6 kg) 720 psig (50 bar) 3D 16 lbs. (7.5 kg) 720 psig (50 bar) 4D 27 lbs. (12.5 kg) 720 psig (50 bar) Form 1100 (12.15) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 25/28 RF Capacitance Level Controls Probe Temperature vs. Pressure Charts 5/16” OD Kynar Coated Cable RF Probe 1 Temperature vs. Pressure - Designator CN, CP 180 180 160 Temperature (degree F) 140 120 100 80 60 40 20 0 0 -20 -50 -40 -60 0 20 30 40 50 60 Pressure (psig) 70 80 90 100 110 Rigid Sheath & Bare RF Probe 2 Temperature vs. Pressure Designator - CA, CB, CC, CE, CJ 400 400 350 Temperature (degree F) 10 300 235 250 200 150 100 70 50 0 -50 -50 -100 0 200 400 600 800 1000 1200 Pressure (psig) 1400 1600 1800 -100 2000 Notes 1. Standard pressure rating: 100 psi @ 70oF. 2. Standard pressure rating: 2000 psi @ 70oF. 26/28 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 1100 (12.15) ©SOR Inc. RF Capacitance Level Controls Level Instruments Application Data Sheet Please use the worksheet/data sheet below to provide SOR with specific details of your application. This will allow us to help you select the proper RF model to ensure optimum performance. You may wish to make copies of the blank form for future use. General Sensor Control Switch Transmitter General Application Conditions Float/ Displacer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Tag Number Application Function Area Classification Agency Approval Probe Model Orientation Style Process Wetted Materials Insertion (in/cm) Process Connection Size Location Enclosure Class Conduit Connection Electronics Model Power Supply No. of Setpoints Type Quantity/Form Rating Type Rating: Amps Load Type Setpoint Location Output Measurement Range Process Media Name Vessel Shape Vessel Material Vessel Lining Press Max. Normal Temp. Max. Normal Ambient Temp. Range Solids (%) Specific Gravity Viscosity (cp) Turbulence Process Coating Vertical/Horizontal _______________in/cm Integral/Remote Ex Pf/I.S./NEMA 4 Contact Name Phone Fax E-mail Rep Company Rep Contact Drawings/Sketches: Please indicate mounting location as well as other connections and internal obstructions. Relay/8 or 16 mA ____________x SPDT/DPDT AC/DC _____________Amps Inductive/Non-Inductive Measured from Process Connection (show on drawing) 4-20 mA Vert. Cylinder/Horiz. Cylinder/Sphere No/Yes Mat’l.__________ __________(cp) Yes/No Yes/No Yes/No 41 42 43 44 45 46 47 Yes/No Form 1100 (12.15) ©SOR Inc. Company Address Hazardous/Non-Hazardous 40 Vibration Mixing Upper Fluid Name Dielectric Constant Lower Fluid Name Dielectric Constant Aeration Ultrasonic Suspended Solids (%) Switches Hydrocarbon Vapors Submersible 48 Cable Length Pressure 49 Nose cone 50 Manufacturer Notes (list any special options) RF Instruments Level/Interface Yes/No SOR SORInc.com Fax completed data sheet to SOR at 913-888-0767. | 913-888-2630 | Registered Quality System to ISO 9001 27/28 SOR Inc. | Lenexa, KS USA | 913-888-2630 | Fax 913-888-0767 | SORInc.com REGIONAL OFFICES China Middle East SOR China | Beijing, China SOR Measurement & Control Equipment Trading DMCC | Dubai, UAE +86 (10) 5820 8767 | Fax +86 (10) 58 20 8770 Form 1100 (12.15) ©SOR Inc. SORInc.com +971 4 278 9632 | Fax +971 4 279 8399 | 913-888-2630 | Registered Quality System to ISO 9001 28/28