exhibit a drawings

advertisement
City of Gaithersburg
31 South Summit Avenue, Gaithersburg, Maryland 20877
REQUEST FOR BIDS
No. 2016-008
CASEY COMMUNITY CENTER
INTERIOR RENOVATIONS
EXHIBIT A
DRAWINGS
MAYOR
Jud Ashman
COUNCIL MEMBERS
Cathy Drzyzgula
Henry Marraffa, Jr.
Michael Sesma
Neil Harris
Ryan Spiegel
CITY MANAGER
Tony Tomasello
SCALE: 1-1/2" = 1'-0"
2'
1'
0
100% SUBMITTAL
0
SCALE: 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
SCALE: 3/16" = 1'-0"
SCALE: 1/8" = 1'-0"
SCALE: 1/16" = 1'-0"
8'
16'
32'
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
SCALE: 3/4" = 1'-0"
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1'
3'
SCALE: 1" = 1'-0"
2'
1'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
2'
0 1/2'
CITY OF GAITHERSBURG - CASEY COMMUNITY CENTER
810 S FREDERICK AVE,
GAITHERSBURG, MARYLAND 20877
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
NIKA A+E
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
PROPOSED DESIGN DRAWINGS
SHEET LIST
SHEET
NUMBER
A001
A002
A003
A100
A101
A102
A103
A200
A201
A300
A400
A401
A402
A403
A405
A406
A407
A600
A601
E001
E101
E102
E103
E501
EDL101
EDL102
EDP101
EL101
EL102
EL501
EL601
EP101
EP501
EP601
M001
M100
M101
M400
M401
M402
M501
M601
P001
P100
P101
P400
P401
P501
P601
SHEET NAME
COVER SHEET
GENERAL NOTES, ABBREVIATIONS & SYMBOLS
LIST OF REQUIRED SUBMITTALS
FIRST FLOOR OVERALL PLAN
SECOND FLOOR OVERALL PLAN
ROOF OVERALL PLAN
SITE PLAN
FIRST FLOOR ELEVATION KITCHEN
FIRST FLOOR ELEVATION CONFERENCE ROOM AND ENTRIES
ROOM SECTIONS AND DETAILS
FIRST FLOOR ENLARGED PLANS - DEMOLITION
FIRST FLOOR ENLARGED PLANS
FIRST FLOOR ENLARGED REFLECTED CEILING PLANS
SECOND FLOOR ENLARGED PLAN - COMPUTER ROOM F - DEMOLITION AND NEW WORK
SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - ROOM F
SECOND FLOOR ENLARGED REFLECTED CEILING PLAN -TEEN ROOM E
SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - DANCE STUDIO
FIRST FLOOR FINISH SCHEDULE
SECOND FLOOR FINISH SCHEDULE
ELECTRICAL NOTES AND SYMBOLS
ELECTRICAL SITE PLAN
ELECTRICAL FIRST FLOOR OVERALL PLAN
ELECTRICAL SECOND FLOOR OVERALL PLAN
ELECTRICAL DETAILS
ELECTRICAL FIRST FLOOR ENLARGED REFLECTED CEILING PLAN - DEMOLITION
ELECTRICAL SECOND FLOOR ENLARGED RCP - COMPUTER ROOM F - DEMOLITION
ELECTRICAL FIRST FLOOR ENLARGED PLANS - DEMOLITION
ELECTRICAL FIRST FLOOR ENLARGED REFLECTED CEILING PLAN
ELECTRICAL SECOND FLOOR ENLARGED RCP - COMPUTER ROOM F
ELECTRICAL LUMINARE SCHEDULE
ELECTRICAL LIGHTING CALCULATIONS - SITE
ELECTRICAL FIRST FLOOR ENLARGED PLANS
ELECTRICAL RISER DIAGRAM
ELECTRICAL PANEL SCHEDULES
MECHANICAL NOTES AND SYMBOLS
MECHANICAL FIRST FLOOR OVERALL PLAN
MECHANICAL SECOND FLOOR OVERALL PLAN
MECHANICAL FIRST FLOOR ENLARGED PLANS - DEMOLITION
MECHANICAL FIRST FLOOR ENLARGED PLAN
MECHANICAL SECOND FLOOR ENLARGED PLAN
MECHANICAL DETAILS
MECHANICAL SCHEDULES
PLUMBING GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
PLUMBING FIRST FLOOR OVERALL PLAN - DEMOLITION
PLUMBING FIRST FLOOR OVERALL PLAN
PLUMBING FIRST FLOOR ENLARGED PLANS - DEMOLITION
PLUMBING FIRST FLOOR ENLARGED PLANS
PLUMBING RISER DIAGRAMS AND SCHEDULE
PLUMBING DETAILS
BUILDING FOOTPRINT AND AREAS OF WORK
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
FLOOR 1: KITCHEN AND LOADING DOCK
SOUTH ENTRY
No.
FLOOR 1: ROOM A
FLOOR 2: DANCE STUDIO
Description
Date
FLOOR 1: ROOM B+C
FLOOR 2: TEEN ROOM
ENTRANCE
NORTH ENTRY
Revisions
FLOOR 1: STORAGE AND CONFERENCE
FLOOR 2: ROOM F
Drawing Title
COVER SHEET
Phase
CONCEPT
A/E Project Number
12-0009.015
Date
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
1:1
Number
A001
SCALE: 1-1/2" = 1'-0"
@
@
C
C
Ø
Ø
P
P
##
A
1'
1'
0
0 1/2'
SCALE: 1" = 1'-0"
SCALE: 3/4" = 1'-0"
C
SCALE: 1/2" = 1'-0"
2'
2'
1'
1'
0
0
SCALE: 1/4" = 1'-0"
8'
8'
4'
4'
2'
2'
0
0
D
SCALE: 3/16" = 1'-0"
12'
12'
8'
8'
4'
4'
0
0
SCALE: 1/8" = 1'-0"
SCALE: 1/16" = 1'-0"
ABV
ABV
A/C
A/C
AC
AC
ACOUST
ACOUST
ADJ
ADJ
AFF
AFF
AHU
AHU
ALT
ALT
ALUM
ALUM
ANC
ANC
ANOD
ANOD
APPROX
APPROX
ARCH
ARCH
ASPH
ASPH
ASTM
ASTM
ATTCH
ATTCH
AUTO
AUTO
AUX
AUX
ABOVE
ABOVE
AIR CONDITIONING
CONDITIONING
AIR
ASPHALT CONCRETE
CONCRETE
ASPHALT
ACOUSTICAL
ACOUSTICAL
ADJUSTABLE/ADJACENT
ADJUSTABLE/ADJACENT
ABOVE FINISHED
FINISHED FLOOR
FLOOR
ABOVE
AIR
AIR HANDLING
HANDLING UNIT
UNIT
ALTERNATE
ALTERNATE
ALUMINUM
ALUMINUM
ANCHOR
ANCHOR
ANODIZED
ANODIZED
APPROXIMATE
APPROXIMATE
ARCHITECTURAL
ARCHITECTURAL
ASPHALT
ASPHALT
AMERICAN
AMERICANSOCIETY
SOCIETY FOR
FOR
TESTING
TESTING AND
AND MATERIALS
MATERIALS
ATTACHMENT
ATTACHMENT
AUTOMATIC
AUTOMATIC
AUXILIARY
AUXILIARY
B
B
BB
BB
BC
BC
BD
BD
BF
BF
BL
BL
BLDG
BLDG
BLKG
BLKG
BLKHD
BLKHD
BM
BM
BO
BO
BOT
BOT
BP
BP
BS
BS
BSMT
BSMT
BTWN
BTWN
BUR
BUR
BASE
BASE
BASE BID
BID
BASE
BRICK COURSE
COURSE
BRICK
BOARD
BOARD
BROOM FINISH
FINISH
BROOM
BUILDING LINE
LINE
BUILDING
BUILDING
BUILDING
BLOCKING
BLOCKING
BULKHEAD
BULKHEAD
BEAM/BENCHMARK
BEAM/BENCHMARK
BY OTHERS/BOTTOM
OTHERS/BOTTOM OF
OF
BY
BOTTOM
BOTTOM
BEARING PLATE
PLATE
BEARING
BOTH SIDES
SIDES
BOTH
BASEMENT
BASEMENT
BETWEEN
BETWEEN
BUILT-UP ROOF
ROOF
BUILT-UP
C
C
CAB
CAB
CAP
CAP
CAT
CAT
CB
CB
CCTV
CCTV
CEM
CEM
CF
CF
CFCI
CFCI
CONDUIT
CONDUIT
CABINET
CABINET
CAPACITY
CAPACITY
CATALOG
CATALOG
CIRCUIT
CIRCUIT BREAKER/CATCH
BREAKER/CATCH BASIN
BASIN
CLOSED CIRCUIT
CIRCUIT TELEVISION
TELEVISION
CLOSED
CEMENT/CEMENTITIOUS
CEMENT/CEMENTITIOUS
CUBIC FEET
FEET
CUBIC
CONTRACTOR-FURNISHED,
CONTRACTOR-FURNISHED,
CONTRACTOR-INSTALLED
CONTRACTOR-INSTALLED
CEILING HEIGHT
HEIGHT
CEILING
CAST IRON
IRON
CAST
CIRCLE
CIRCLE
CIRCUMFERENCE
CIRCUMFERENCE
CONTROL JOINT
JOINT
CONTROL
CAULKING
CAULKING
CEILING
CEILING
CLEAR
CLEAR
CENTIMETER
CENTIMETER
CONCRETE MASONRY
MASONRY UNIT
UNIT
CONCRETE
CLEAN OUT/CASED
OUT/CASED OPENING
OPENING
CLEAN
COLUMN
COLUMN
CONCRETE
CONCRETE
CONSTRUCTION
CONSTRUCTION
CONTINUOUS
CONTINUOUS
CORRIDOR
CORRIDOR
CHROME PLATED
PLATED
CHROME
COUNTERSINK
COUNTERSINK
CASEMENT
CASEMENT
CERAMIC TILE
TILE
CERAMIC
CENTER
CENTER
CLEAR WIRE
WIRE GLASS
GLASS
CLEAR
CUBIC YARDS
YARDS
CUBIC
CH
CH
CI
CI
CIR
CIR
CIRC
CIRC
CJ
CJ
CLKG
CLKG
CLG
CLG
CLR
CLR
CM
CM
CMU
CMU
CO
CO
COL
COL
CONC
CONC
CONSTR
CONSTR
CONT
CONT
CORR
CORR
CP
CP
CS
CS
CSMT
CSMT
CT
CT
CTR
CTR
CWG
CWG
CY
CY
4'
4'
0
0
1'
1'
2'
2'
3'
3'
B
E
16'
16'
8'
8'
4'
4'
0
0
32'
32'
16'
16'
8'
8'
G
G
G
GA
GA
GAL
GAL
GALV
GALV
GB
GB
GC
GC
GFCI
GFCI
GFGI
GFGI
2'
2'
0
0
1'
1'
∠
∠
AND
AND
ANGLE
ANGLE
AT
AT
CENTER LINE
LINE
CENTER
DIAMETER
DIAMETER
PLATE
PLATE
POUND/NUMBER
POUND/NUMBER
F
D
D
dB
dB
DBL
DBL
DEMO
DEMO
DET
DET
DF
DF
DG
DG
DH
DH
DIA
DIA
DIM
DIM
DISP
DISP
DL
DL
DN
DN
DP
DP
DR
DR
DS
DS
DWG
DWG
DWR
DWR
(E)
(E)
E
E
EA
EA
EF
EF
EG
EG
EGC
EGC
EJ
EJ
ELEC
ELEC
ELEV
ELEV
ENCL
ENCL
ENTR
ENTR
EQ
EQ
EQUIP
EQUIP
EIFS
EIFS
DEPTH
DEPTH
DECIBELS
DECIBELS
DOUBLE
DOUBLE
DEMOLISH/DEMOLITION
DEMOLISH/DEMOLITION
DETAIL
DETAIL
DRINKING FOUNTAIN
FOUNTAIN
DRINKING
DAY GATE
GATE
DAY
DOUBLE HUNG
HUNG
DOUBLE
DIAMETER
DIAMETER
DIMENSION
DIMENSION
DISPENSER
DISPENSER
DEAD LOAD
LOAD
DEAD
DOWN
DOWN
DAMPPROOFING
DAMPPROOFING
DOOR
DOOR
DOWNSPOUT
DOWNSPOUT
DRAWING
DRAWING
DRAWER
DRAWER
ESC
ESC
EST
EST
EW
EW
EXH
EXH
EXIST
EXIST
EXP
EXP
EXT
EXT
EXISITING
EXISITING
EAST
EAST
EACH
EACH
EACH FACE
FACE
EACH
FOR EXAMPLE
EXAMPLE
FOR
EPOXY GLAZED COATING
COATING
EPOXY
EXPANSION JOINT
JOINT
EXPANSION
ELECTRICAL
ELECTRICAL
ELEVATOR/ELEVATION
ELEVATOR/ELEVATION
ENCLOSURE
ENCLOSURE
ENTRANCE
ENTRANCE
EQUAL
EQUAL
EQUIPMENT
EQUIPMENT
EXTERIOR INSULATION
INSULATION
EXTERIOR
& FINISH
FINISH SYSTEM
SYSTEM
&
ESCALATOR
ESCALATOR
ESTIMATED
ESTIMATED
EACH WAY
WAY
EACH
EXHAUST
EXHAUST
EXISTING
EXISTING
EXPANSION/EXPANDED
EXPANSION/EXPANDED
EXTERIOR
EXTERIOR
FF
FA
FA
FBG
FBG
FDN
FDN
FE/BR
FE/BR
FEW
FEW
FIG
FIG
FIN
FIN
FIXT
FIXT
FL
FL
FLEX
FLEX
FLUOR
FLUOR
FM
FM
FO
FO
FRT
FRT
FT
FT
FTG
FTG
FURN
FURN
FURR
FURR
FLAME/FLUSH
FLAME/FLUSH
FIRE ALARM
ALARM
FIRE
FOIL-BACKED GYPSUM
GYPSUM BOARD
BOARD
FOIL-BACKED
FOUNDATION
FOUNDATION
FORCED-ENTRY/BALLISTIC-RESISTANT
FORCED-ENTRY/BALLISTIC-RESISTANT
FIRE EXTINGUISHER
EXTINGUISHER WALL
WALL MOUNTED
MOUNTED
FIRE
FIGURE
FIGURE
FINISH
FINISH
FIXTURE
FIXTURE
FLASH FLOOR
FLOOR
FLASH
FLEXIBLE
FLEXIBLE
FLUORESCENT
FLUORESCENT
FACTORY MUTUAL
MUTUALRESEARCH
RESEARCHCORP.
CORP.
FACTORY
FACE OF
OF
FACE
FIRE RETARDANT
RETARDANT TREATED
TREATED
FIRE
FOOT/FEET
FOOT/FEET
FOOTING
FOOTING
FURNITURE/FURNISHED
FURNITURE/FURNISHED
FURRING
FURRING
GENERAL NOTES:
MATERIAL SYMBOLS
GFE
GFE
GL
GL
GOVT
GOVT
GND
GND
GR
GR
GWB
GWB
GYP BD
BD
GYP
H
I
J
K
L
M
N
O
P
Q
GUTTER
GUTTER
GAUGE
GAUGE
GALLON
GALLON
GALVANIZED
GALVANIZED
GRAB BAR/GYPSUM
BAR/GYPSUM BOARD
BOARD
GRAB
GENERAL CONTRACTOR
CONTRACTOR
GENERAL
GOVERNMENT-FURNISHED,
GOVERNMENT-FURNISHED,
CONTRACTOR-INSTALLED
CONTRACTOR-INSTALLED
GOVERNMENT-FURNISHED,
GOVERNMENT-FURNISHED,
GOVERNMENT-INSTALLED
GOVERNMENT-INSTALLED
GOVERNMENT FURNISHED
FURNISHED EQUIPMENT
EQUIPMENT
GOVERNMENT
GLASS/GLAZED
GLASS/GLAZED
GOVERNMENT
GOVERNMENT
GROUND
GROUND
GRADING/GRADE
GRADING/GRADE
GYPSUM
GYPSUM WALLBOARD
WALLBOARD
GYPSUM BOARD
BOARD
GYPSUM
HC
HC
HD
HD
HDWD
HDWD
HDWR
HDWR
HH
HH
HM
HM
HOR
HOR
HP
HP
HR
HR
HTG
HTG
HT/H
HT/H
HVAC
HVAC
HOLLOW
HOLLOW CORE
CORE
HEAD/HEAVY
HEAD/HEAVY DUTY
DUTY
HARDWOOD
HARDWOOD
HARDWARE
HARDWARE
HAND
HAND HOLE
HOLE
HOLLOW
HOLLOW METAL
METAL
HORIZONTAL
HORIZONTAL
HORSEPOWER
HORSEPOWER
HOUR
HOUR
HEATING/HEAT
HEATING/HEAT
HEIGHT/HIGH
HEIGHT/HIGH
HEATING, VENTILATING
VENTILATING
HEATING,
& AIR
AIR CONDITIONING
CONDITIONING
&
HZ
HZ
HERTZ
HERTZ
ID
ID
IG
IG
IIC
IIC
IN
IN
INCL
INCL
INFO
INFO
INSUL
INSUL
INT
INT
INSIDE DIAMETER/
DIAMETER/
INSIDE
INTERIOR DIMENSION
DIMENSION
INTERIOR
INSULATED GLASS
GLASS
INSULATED
IMPACT INSULATION
INSULATION CLASS
CLASS
IMPACT
INCH
INCH
INCLUDING
INCLUDING
INFORMATION
INFORMATION
INSULATION
INSULATION
INTERIOR
INTERIOR
JAN
JAN
JB
JB
JST
JST
JT
JT
JANITOR
JANITOR
JAMB
JAMB
JOIST
JOIST
JOINT
JOINT
KD
KD
KIT
KIT
KO
KO
KPA
KPA
KW
KW
KNOCK-DOWN/KILN-DRIED
KNOCK-DOWN/KILN-DRIED
KITCHEN
KITCHEN
KNOCK OUT
OUT
KNOCK
KILOPASCAL
KILOPASCAL
KILOWATT
KILOWATT
LL
L/S
L/S
LAM
LAM
LB
LB
LBL
LBL
LF
LF
LG
LG
LH
LH
LL
LL
LP
LP
LT
LT
LTG
LTG
LONG
LONG
LITERS PER
PER SECOND
SECOND
LITERS
LAMINATE(D)
LAMINATE(D)
POUND/LOAD-BEARING
POUND/LOAD-BEARING
LABEL
LABEL
LINEAR FEET
FEET
LINEAR
LONG/LENGTH
LONG/LENGTH
LEFT HAND
HAND
LEFT
LIVE LOAD
LOAD
LIVE
LOW POINT
POINT
LOW
LIGHT
LIGHT
LIGHT/LIGHTING
LIGHT/LIGHTING
M
M
MAS
MAS
MAT/MATL
MAT/MATL
MAX
MAX
MECH
MECH
MED
MED
MEMB
MEMB
MET/MTL
MET/MTL
MFR
MFR
MH
MH
MIN
MIN
MIR
MIR
MISC
MISC
MIX
MIX
ML
ML
MLD
MLD
MM
MM
MO
MO
MS
MS
MT
MT
MTD
MTD
MTG
MTG
MULL
MULL
METER
METER
MASONRY
MASONRY
MATERIAL
MATERIAL
MAXIMUM
MAXIMUM
MECHANICAL
MECHANICAL
MEDIUM
MEDIUM
MEMBRANE
MEMBRANE
METAL
METAL
MANUFACTURER
MANUFACTURER
MOUNTING HEIGHT
HEIGHT
MOUNTING
MINIMUM
MINIMUM
MIRROR
MIRROR
MISCELLANEOUS
MISCELLANEOUS
MIXTURE
MIXTURE
MATCH LINE
LINE
MATCH
MOLDING
MOLDING
MILLIMETER
MILLIMETER
MASONRY OPENING
OPENING
MASONRY
MOTOR STARTER
STARTER
MOTOR
MARBLE THRESHOLD
THRESHOLD
MARBLE
MOUNTED
MOUNTED
MOUNTING
MOUNTING
MULLION
MULLION
N
N
N/A
N/A
NIC
NIC
NLB
NLB
NO
NO
NOM
NOM
NSF
NSF
NTS
NTS
NORTH
NORTH
NOT APPLICABLE
APPLICABLE
NOT
NOT IN
IN CONTRACT
CONTRACT
NOT
NON-LOAD BEARING
BEARING
NON-LOAD
NUMBER
NUMBER
NOMINAL
NOMINAL
NATIONAL SANITATION
SANITATION FOUNDATION
FOUNDATION
NATIONAL
NOT TO
TO SCALE
SCALE
NOT
OC
OC
OD
OD
OFF
OFF
OH
OH
OPHD
OPHD
OPNG
OPNG
OPP
OPP
OZ
OZ
PA
PA
PC
PC
PCF
PCF
PF
PF
PFB
PFB
PLAM
PLAM
PLAS
PLAS
PLF
PLF
PNL
PNL
PNT
PNT
POLY
POLY
PR
PR
PRESS TR
TR
PRESS
PRF
PRF
PSF
PSF
PT
PT
PRCST
PRCST
PVC
PVC
PWD
PWD
PTN
PTN
P.T.
P.T.
QT
QT
QTB
QTB
QUAL
QUAL
ON CENTER
CENTER
ON
OUTSIDE DIAMETER
DIAMETER
OUTSIDE
OFFICE
OFFICE
OVERHEAD
OVERHEAD
OPPOSITE HAND
HAND
OPPOSITE
OPENING
OPENING
OPPOSITE HAND
HAND
OPPOSITE
OUNCE(S)
OUNCE(S)
PASCAL
PASCAL
PORTLAND CEMENT
CEMENT
PORTLAND
POUNDS PER
PER CUBIC
CUBIC FOOT
FOOT
POUNDS
POLISH FINISH
FINISH
POLISH
PREFABRICATE
PREFABRICATE
PLASTIC LAMINATE
LAMINATE
PLASTIC
PLASTER
PLASTER
POUNDS PER
PER LINEAR
LINEAR FOOT
FOOT
POUNDS
PANEL
PANEL
PAINT
PAINT
POLYETHYLENE
POLYETHYLENE
PAIR
PAIR
PRESSURE TREATED
TREATED
PRESSURE
PREFINISHED
PREFINISHED
POUNDS PER
PER SQUARE
SQUARE FOOT
FOOT
POUNDS
POINT
POINT
PRECAST
PRECAST
POLYVINYL CHLORIDE
CHLORIDE
POLYVINYL
PLYWOOD
PLYWOOD
PARTITION
PARTITION
PRESSURE TREATED
TREATEDWOOD
WOOD
PRESSURE
QUARRY TILE
TILE
QUARRY
QUARRY TILE
TILE BASE
BASE
QUARRY
QUALITY
QUALITY
R
RA
RA
RAF
RAF
RAD/r
RAD/r
RCP
RCP
REBAR
REBAR
REC
REC
REF
REF
REGIS
REGIS
REINF
REINF
REM
REM
REPL
REPL
REQD
REQD
RESIL
RESIL
RET
RET
REV
REV
RF
RF
RGS
RGS
RH
RH
RM
RM
RO
RO
RWL
RWL
RWD
RWD
RETURN AIR
AIR
RETURN
RELILIENT ATHLETIC
ATHLETIC FLOORING
FLOORING
RELILIENT
RADIUS
RADIUS
REFLECTED CEILING
CEILING PLAN
PLAN
REFLECTED
REINFORCING BAR
BAR
REINFORCING
RECEPTACLE
RECEPTACLE
REFERENCE
REFERENCE
REGISTRATION
REGISTRATION
REINFORCING/REINFORCED
REINFORCING/REINFORCED
REMOVE
REMOVE
REPLACE
REPLACE
REQUIRED
REQUIRED
RESILIENT
RESILIENT
RETURN AIR
AIR
RETURN
REVISE/REVISION
REVISE/REVISION
ROUGH
ROUGH FINISH
FINISH
RIGID GALVANIZED
GALVANIZED STEEL
STEEL
RIGID
RIGHT
RIGHT HAND
HAND
ROOM
ROOM
ROUGH
ROUGH OPENING
OPENING
RAIN
RAIN WATER
WATER LEADER
LEADER
REDWOOD
REDWOOD
S
S
SA
SA
SAC
SAC
SC
SC
SCH
SCH
SDG
SDG
SDT
SDT
SECT
SECT
SF
SF
SG(#)
SG(#)
SH
SH
SHTH
SHTH
SIM
SIM
SJ
SJ
SM
SM
SPEC
SPEC
SQ
SQ
SQ
SQ YD
YD
SQ
SQ FT
FT
SS
SS
STA
STA
STD
STD
ST
ST STL
STL
STL
STL
SUSP
SUSP
SV
SV
SW
SW
SYM
SYM
SYS
SYS
SHT, SH
SH
SHT,
STOR
STOR
STRUCT
STRUCT
SOUTH
SOUTH
SUPPLY
SUPPLY AIR
AIR
SUSPENDED
SUSPENDED ACOUSTICAL
ACOUSTICAL CEILING
CEILING
SOLID CORE
CORE
SOLID
SCHEDULE
SCHEDULE
SIDING
SIDING
STATIC DISSIPATIVE
DISSIPATIVE TILE
TILE
STATIC
SECTION
SECTION
SEAMLESS FLOORING
FLOORING
SEAMLESS
DUCT SECURITY
SECURITYGRILL
GRILL(TYPE
(TYPE #)
#)
DUCT
SHELF
SHELF
SHEATHING
SHEATHING
SIMILAR
SIMILAR
STEEL JOIST
JOIST
STEEL
SURFACE MOUNTED
MOUNTED
SURFACE
SPECIFICATION
SPECIFICATION
SQUARE
SQUARE
SQUARE YARD
YARD
SQUARE
SQUARE FOOT
FOOT
SQUARE
STAINLESS STEEL
STEEL
STAINLESS
STATION
STATION
STANDARD
STANDARD
STAINLESS STEEL
STEEL
STAINLESS
STEEL
STEEL
SUSPENDED
SUSPENDED
SHEET
SHEET VINYL
VINYL
SWITCH
SWITCH
SYMMETRICAL
SYMMETRICAL
SYSTEM
SYSTEM
SHEET
SHEET
STORAGE
STORAGE
STRUCTURE
STRUCTURE
TT
TB
TB
TC
TC
TELE
TELE
TEMP
TEMP
TER
TER
TF
TF
T&G
T&G
THK
THK
THR
THR
THRU
THRU
TO
TO
TOC
TOC
TOS
TOS
TOW
TOW
TW
TW
TYP
TYP
TREAD/THICK
TREAD/THICK
TOWEL BAR
BAR
TOWEL
TOP OF
OF CURB
CURB
TOP
TELEPHONE/TELECOM
TELEPHONE/TELECOM
TEMPORARY
TEMPORARY
TERRAZZO
TERRAZZO
TROWEL FINISH
FINISH
TROWEL
TONGUE && GROOVE
GROOVE
TONGUE
THICK/THICKNESS
THICK/THICKNESS
THRESHOLD
THRESHOLD
THROUGH
THROUGH
TOP OF
OF
TOP
TOP OF
OF CONCRETE
CONCRETE
TOP
TOP OF
OF STEEL
STEEL
TOP
TOP OF
OF WALL
WALL
TOP
TOP OF
OF WALL
WALL
TOP
TYPICAL
TYPICAL
UC
UC
UL
UL
UNF
UNF
UNO
UNO
URM
URM
UNDERCUT
UNDERCUT
UNDERWRITER'S LABORATORIES
LABORATORIES
UNDERWRITER'S
UNFINISHED
UNFINISHED
UNLESS NOTED
NOTED OTHERWISE
OTHERWISE
UNLESS
UNREINFORCED MASONRY
MASONRY
UNREINFORCED
V
V
(V)
(V)
VAV
VAV
VB
VB
VCB
VCB
VCT
VCT
VD
VD
VENT'D
VENT'D
VERT
VERT
VEST
VEST
VJ
VJ
VOL
VOL
VT
VT
VWC
VWC
VENT/VOLT/VALVE
VENT/VOLT/VALVE
VERIFY
VERIFY
VARIABLE AIR
AIR VOLUME
VOLUME
VARIABLE
VAPOR BARRIER
BARRIER
VAPOR
VINYL COVE
COVE BASE
BASE
VINYL
VINYL COMPOSITION
COMPOSITION TILE
TILE
VINYL
VOLUME DAMPER/VAULT
DAMPER/VAULT DOOR
DOOR
VOLUME
VENTED
VENTED
VERTICAL
VERTICAL
VESTIBULE
VESTIBULE
V-JOINT
V-JOINT
VOLUME
VOLUME
VINYL TILE
TILE
VINYL
VINYL WALL
WALL COVERING
COVERING
VINYL
W
WD
WD
WOOD
WOOD
X
XFMR
XFMR
S
T
U
V
EARTH
EARTH
FIBER BOARD
BOARD OR
OR
FIBER
RIGID INSULATION
INSULATION
RIGID
GRAVEL OR
OR
GRAVEL
POROUS FILL
FILL
POROUS
PLASTER,
PLASTER, GYPSUM
GYPSUM
WALL
WALL BOARD,
BOARD,
MORTAR,
MORTAR, OR
OR
PARTICLE
PARTICLE BOARD
BOARD
CONCRETE
CONCRETE
MASONRY UNIT
UNIT
MASONRY
FINISHED WOOD
WOOD
FINISHED
BRICK
BRICK
ROUGH
ROUGH WOOD
WOOD
STONE
STONE
PLYWOOD
PLYWOOD
CONCRETE
CONCRETE
STEEL OR
OR IRON
IRON
STEEL
FIBROUS
FIBROUS
INSULATION
INSULATION
ALUMINUM
ALUMINUM
1.
1. CONTRACTOR
CONTRACTORSHALL
SHALL AT
AT ALL
ALL TIMES
TIMES RETAIN
RETAIN AN
AN APPROVED SET OF PERMIT DRAWINGS ON THE CONSTRUCTION
PREMISE.
CONSTRUCTION PREMISE.
2.
2. CONTRACTOR
CONTRACTORSHALL
SHALL BE
BE RESPONSIBLE
RESPONSIBLE FOR OBTAINING
OBTAINING ADDITIONAL
ADDITIONAL TRADE
TRADE PERMITS
PERMITS FOR
FOR ELECTRICAL,
ELECTRICAL,
MECHANICAL
ETC.
WORK
AS
REQUIRED.
MECHANICAL ETC. WORK AS REQUIRED.
3.
3. CONTRACTOR
CONTRACTORSHALL
SHALL COMPLY
COMPLY WITH
WITH THE
THE BUILDING
BUILDING RULES
RULES AND
AND REGULATIONS
REGULATIONS FOR
FOR WORKING
WORKING HOURS,
HOURS, DELIVERY
AND
HANDLING
OF MATERIAL,
AND CONSTRUCTION
WASTE REMOVAL.
DELIVERY
AND HANDLING
OF MATERIAL,
AND CONSTRUCTION
WASTE REMOVAL.
4.IN ORDER TO FACILITATE MINIMUM DISRUPTION TO ROUTINE
ROUTINE OPERATIONS
OPERATIONS OF THE STATION,
STATION, THE CONTRACTOR
SHALL
REQUIRE
TO SCHEDULE
PORTIONS
OF THE
CONSTRUCTION
DURING WEEKENDS,
AND
AFTER HOURS.
CONTRACTOR
SHALL
REQUIRE TO
SCHEDULE
PORTIONS
OF THE CONSTRUCTION
DURING
WEEKENDS,
AND
5.
DO NOT
SHORE OR HANDLE ANY CONSTRUCTION MATERIAL IN THE PATH TO EGRESS UNDER ANY
AFTER
HOURS.
CIRCUMSTANCES.
5. DO NOT SHORE OR HANDLE ANY CONSTRUCTION MATERIAL IN THE PATH TO EGRESS UNDER ANY
6.
DURING CONSTRUCTION PORTIONS OF THE BUILDING OUTSIDE OF THE SCOPE OF WORK SHALL REMAIN
CIRCUMSTANCES.
OCCUPIED
OPERATIONAL.
OCCUPIED
OF THE
STRUCTURE
BE OF
SEPARATED
FROM
PORTIONS
6. DURINGAND
CONSTRUCTION
PORTIONS
OFPORTIONS
THE BUILDING
OUTSIDE
OF THEWILL
SCOPE
WORK SHALL
REMAIN
OF
THE STRUCTURE
UNDERGOING
ALTERATION,
CONSTRUCTION,
OR DEMOLITION
BY TEMPORARY
OCCUPIED
AND OPERATIONAL.
OCCUPIED
PORTIONS
OF THE STRUCTURE
WILL BE OPERATIONS
SEPARATED FROM
WALLS
WITH AOF
MINIMUM
1-HR FIRE UNDERGOING
RESISTANCE RATING
IN ACCORDANCE
WITH NFPA
241 §8.6.2. OPENING
PORTIONS
THE STRUCTURE
ALTERATION,
CONSTRUCTION,
OR DEMOLITION
OPERATIONS
PROTECTIVES
WILL
HAVE
AT
LEAST
A
45-MINUTE
FIRE
PROTECTION
RATING.
BY TEMPORARY WALLS WITH A MINIMUM 1-HR FIRE RESISTANCE RATING IN ACCORDANCE WITH NFPA 241 §
7.
EXTREME
CARE
SHALL BE EXERCISED
DRILLING OR
ANCHORING
TO THE
EXISTING STRUCTURE. IF
8.6.2.
OPENING
PROTECTIVES
WILL HAVE IN
ATCUTTING,
LEAST A 45-MINUTE
FIRE
PROTECTION
RATING.
ANY
DETERIORATION
OR DAMAGE
TO THE IN
EXISTING
STRUCTURE
OCCURS
DURING
IT SHALL BE
7. EXTREME
CARE SHALL
BE EXERCISED
CUTTING,
DRILLING OR
ANCHORING
TOCONSTRUCTION,
THE EXISTING STRUCTURE.
IMMEDIATELY
REPORTED
TO
THE
CITY
AND
ARCHITECT-ENGINEER
OF
THE
RECORD.
IF ANY DETERIORATION OR DAMAGE TO THE EXISTING STRUCTURE OCCURS DURING CONSTRUCTION, IT SHALL
8.
BE RESPONSIBLE
FOR ARCHITECT-ENGINEER
SCHEDULING ALL CONSTRUCTION
INSPECTION WITH APPROPRIATE
BECONTRACTOR
IMMEDIATELY SHALL
REPORTED
TO THE CITY AND
OF THE RECORD.
CODE
OFFICER DURING
ASFOR
REQUIRED.
8. CONTRACTOR
SHALLCONSTRUCTION
BE RESPONSIBLE
SCHEDULING ALL CONSTRUCTION INSPECTION WITH
9.
CONTRACTOR
IS RESPONSIBLE
FOR CONSTRUCTION
ALL TEMPORARYAS
SHORING,
SUPPORT AND PROTECTION OF EXISTING
APPROPRIATE
CODE
OFFICER DURING
REQUIRED.
CONDITIONS
TO
REMAIN
DURING
CONSTRUCTION.
9. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING, SUPPORT AND PROTECTION OF EXISTING
10.CONTRACTOR
IS RESPONSIBLE
FOR MAINTAINING SAFE WORK ENVIRONMENT AND COMPLIANCE WITH OSHA
CONDITIONS TO REMAIN
DURING CONSTRUCTION.
SAFETY
STANDARD DURING
CONSTRUCTION.
10.
CONTRACTOR
IS RESPONSIBLE
FOR MAINTAINING SAFE WORK ENVIRONMENT AND COMPLIANCE WITH
11.CONTRACTOR
SHALL COORDINATE
WITH THE CITY FOR TEMPORARY SHUT DOWN OF ANY BUILDING SYSTEM
OSHA SAFETY STANDARD
DURING CONSTRUCTION.
DURING
CONSTRUCTION.
11.CONTRACTOR
SHALL COORDINATE WITH THE CITY FOR TEMPORARY SHUT DOWN OF ANY BUILDING SYSTEM
12.REMOVE
ANY NAILS, SCREWS, SURFACE MOUNTED RACEWAY, HARDWARE, NON-FUNCTIONING ELECTRICAL
DURING CONSTRUCTION.
DEVICES
AND
OTHER
EXPOSED
ITEMS
ON EXISTING
WALLS/PORTIONS
IN THE AREA
OF NEW WORK.ELECTRICAL
12.REMOVE
ANY
NAILS,
SCREWS,
SURFACE
MOUNTED
RACEWAY, HARDWARE,
NON-FUNCTIONING
13.
PATCHAND
ANDOTHER
REPAIR
RESULTING
WALL/PARTITION
DAMAGE AS REQUIRED
SURFACES
DEVICES
EXPOSED
ITEMS
ON EXISTING WALLS/PORTIONS
IN THEPREPARING
AREA OF NEW
WORK. TO RECEIVE
NEW
FINISHES
SCHEDULED.
13. PATCH
ANDAS
REPAIR
RESULTING WALL/PARTITION DAMAGE AS REQUIRED PREPARING SURFACES TO
14.CONTRACTOR
SHALL AT
TIMES KEEP THE PREMISES CLEAN AND FREE OF ACCUMULATIONS OF WASTE
RECEIVE NEW FINISHES
ASALL
SCHEDULED.
MATERIAL
AND RUBBISH
CAUSED
BY THE
CONSTRUCTION.
14.CONTRACTOR
SHALL AT
ALL TIMES
KEEP
THE PREMISES CLEAN AND FREE OF ACCUMULATIONS OF WASTE
15.MANUFACTURER
NAMES
AND
PRODUCT
ARE
INDICATING ON DRAWINGS TO INDICATE MINIMUM PERFORMANCE
MATERIAL AND RUBBISH CAUSED BY THE CONSTRUCTION.
CRITERIA.
EQUALS OR
COMPARABLE
MAY BE
SUBMITTED
FOR
DURING
THE SUBMITTAL
PROCESS.
15.MANUFACTURER
NAMES
AND PRODUCT
ARE
INDICATING
ONREVIEW
DRAWINGS
TO INDICATE
MINIMUM
16.CONTRACTOR
SHALL FULLY
COMPLY
WITH ALL REQUIREMENTS
OF "GENERAL
CONDITIONS"
BY THE
PERFORMANCE CRITERIA.
EQUALS
OR COMPARABLE
MAY BE SUBMITTED
FOR REVIEW
DURINGFURNISHED
THE SUBMITTAL
CITY
PROCESS.
17.
CONTRACTOR SHALL
SHALL FULLY
COORDINATE
PHASING WITH
THE CITY. PRIOR
TO COMMENCEMENT
16.CONTRACTOR
COMPLYCONSTRUCTION
WITH ALL REQUIREMENTS
OF "GENERAL
CONDITIONS"
FURNISHED BYOF ANY
CONSTRUCTION
ACTIVITY.
THE CITY
18.
DIMENSIONS
FOR COORDINATE
NEW WALLS ARE
FROM FACE OF
STUD FRAMING
OTHERWISE
NOTED.
17. ALL
CONTRACTOR
SHALL
CONSTRUCTION
PHASING
WITH THEUNLESS
CITY. PRIOR
TO COMMENCEMENT
19.
FORACTIVITY.
NEW INTERIOR DOORS ARE TO THE CENTER OF DOORS, UNLESS OTHERWISE NOTED.
OF ALL
ANYDIMENSIONS
CONSTRUCTION
20.
RAW
WOOD
SEALED/PAINTED
LEAD-FREE,
NON -METALLIC,
CLEANABLE
18. ALL EXPOSED
DIMENSIONS
FOR
NEWSHALL
WALLSBE
ARE
FROM FACE OFWITH
STUDAFRAMING
UNLESS
OTHERWISEEASILY
NOTED.
PAINT
A HIGH QUALITY
VARNISH.
19. ALLFOR
DIMENSIONS
FOR NEW
INTERIOR DOORS ARE TO THE CENTER OF DOORS, UNLESS OTHERWISE NOTED.
21. ALL ANNULAR OPENINGS IN CONSTRUCTION SHALL BE SEALED/CAULKED TO WITHIN 1/32 OF AN INCH.
22. ALL EXHAUST HOODS OVER COOKING EQUIPMENT WILL BE CAPABLE OF CAPTURING AND EXHAUSTING SMOKE
GENERATED FROM A 60-SECOND SMOKE BOMB.
REFERENCE SYMBOLS
REFERENCE SYMBOLS
WALL SECTION
WALL SECTION
DETAIL/ SECTION NUMBER
DETAIL/ SECTION NUMBER
SIMILAR INDICATION
SIMILAR INDICATION
SIM
1
SIM
1
A101
BUILDING SECTION
BUILDING SECTION
DETAIL SECTION
DETAIL SECTION
EXTERIOR ELEVATION
EXTERIOR ELEVATION
INTERIOR ELEVATION
INTERIOR ELEVATION
1
1
A101
A101
LEVEL DESCRIPTION
LEVEL DESCRIPTION
LEVEL 1
0'-0"
LEVEL
1
0'-0"
FLOOR ELEVATION
FLOOR ELEVATION
LEVEL ELEVATION
LEVEL ELEVATION
SHEET NUMBER
SHEET NUMBER
A101
SIM
SIM
NEW COLUMN
NEW COLUMN
NEW COLUMN GRID
INDICATOR
NEW
COLUMN GRID
INDICATOR
0
0
NEW COLUMN GRID
LINE COLUMN GRID
NEW
LINE
SIM
1
SIM
A101
1
A101
EXISTING
COLUMN
EXISTING
COLUMN
EXISTING COLUMN
GRID INDICATOR
EXISTING
COLUMN
GRID INDICATOR
2
2
EXISTING COLUMN
GRID LINE COLUMN
EXISTING
GRID LINE
ELEVATION NUMBER
ELEVATION NUMBER
1
1
A101
A101
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
1 / A103
11 / A103
A102
MATCH LINE
MATCH LINE
1 / A102
SHEET NUMBER
SHEET
MATCHNUMBER
LINE
MATCH LINE
ELEVATION NUMBER
ELEVATION NUMBER
2
2 3
1 A601
1 A601 3
4
4
SHEET NUMBER
SHEET NUMBER
REVISION NUMBER
(SHEET SPECIFIC)
REVISION
NUMBER
(SHEET SPECIFIC)
1
1
REVISION
REVISION
CLOUDED AREA OF
REVISION AREA OF
CLOUDED
REVISION
TRANSFORMER
TRANSFORMER
RCP LEGEND
1
1
A101
GYPSUM CEILING
CEILING
GYPSUM
LARGE SCALE BLOWUP
OF PLAN
OR DETAIL
LARGE
SCALE
BLOWUP
OF PLAN OR DETAIL
A101
SIM
SIM
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
N
N
NORTH ARROW
NORTH ARROW
W
W
2X4 ACOUSTICAL
ACOUSTICAL CEILING
CEILING TILE
TILE
2X4
2X4 PVC
PVC ACOUSTICAL
ACOUSTICAL CEILING
CEILING TILE
TILE
2X4
2'-0" X
X 2'-0" CEILING/ CASSETTE
CASSETTE DIFFUSER
DIFFUSER
2'-0"
PARTITION TYPE
PARTITION TYPE
2'-0" X
X 2'-0"
2'-0" CEILING EXHAUST
EXHAUST GRILLE
GRILLE
2'-0"
DOOR SYMBOL
DOOR SYMBOL
FA
24
FA
24
EXTERIOR WINDOW
SYMBOL WINDOW
EXTERIOR
SYMBOL
LOUVER SYMBOL
LOUVER SYMBOL
6" RECESSED CANISTER
CANISTER LIGHT
LIGHT FIXTURE
FIXTURE
6"
W-101
W-101
L-101
L-101
CEILING SPRINKLER
SPRINKLER HEAD
HEAD
CEILING
EMERGENCY WALL
WALL LIGHT
LIGHT
EMERGENCY
TRUE NORTH
TRUE NORTH
ROOM NAME AND
NUMBER
ROOM
NAME AND
NUMBER
PARTITION CONFIGURATION
PARTITION CONFIGURATION
"A" INDICATES SOUNDBATT INSULATION
"A" INDICATES SOUNDBATT INSULATION
FRAMING SIZE DESIGNATION
FRAMING SIZE DESIGNATION
FIRE-RATING/ PARTITION
HEIGHT DESIGNATION
FIRE-RATING/
PARTITION
HEIGHT DESIGNATION
SHEET NOTE SYMBOLS
SHEET NOTE SYMBOLS
2
2
2
2
KEYNOTE
KEYNOTE
05500
05500
DOOR OR BORROWED LIGHT NUMBER
DOOR OR BORROWED LIGHT NUMBER
X 44 RECESSED LIGHT
LIGHT FIXTURE
FIXTURE
22 X
EXIT (EGRESS)
(EGRESS) SIGN
SIGN
EXIT
E
E
ARCHITECTURE / INTERIORS SYMBOLS
ARCHITECTURE / INTERIORS SYMBOLS
NEW ACOUSTIC
ACOUSTIC BAFFLE
BAFFLE ARRAY
ARRAY
NEW
2'-0' X 2'-0" CEILING ACCES PANEL
PANEL
2'-0'
PLAN NORTH
PLAN NORTH
S
S
101101
2'
2'
&
&
0
0
IF
IF THIS
THIS DRAWING
DRAWING IS
IS A
A REPRODUCTION,
REPRODUCTION, GRAPHIC
GRAPHIC SCALE
SCALE MUST
MUST BE
BE USED
USED
ABBREVIATIONS:
ROOM NAME
ROOM
100NAME
100
WINDOW NUMBER
WINDOW NUMBER
TOILET ACCESSORY
TOILET ACCESSORY
WALL PROTECTION
WALL PROTECTION
LOUVER NUMBER
LOUVER NUMBER
ROOM NAME
ROOM NAME
ROOM NUMBER
ROOM NUMBER
TA-10
TA-10
CG-1
CG-1
CR-1
CR-1
HR-1
HR-1
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
APPLICABLE CODES,
APPLICABLE CODES,
STANDARD AND AUTHORITY
STANDARD AND AUTHORITY
ALL WORK RELATED TO THIS PROJECT SHALL BE
ALL
WORK RELATED
TO THIS PROJECT
SHALL
BE
PERFORMED
IN ACCORDANCE
WITH THE
FOLLOWING
PERFORMED
IN ACCORDANCE
WITH THE FOLLOWING
CODES, AND CRITERIA
AS APPLICABLE.
CODES, AND CRITERIA AS APPLICABLE.
•
2012 International Building Code (IBC)
•
2012
International
Building Code (IBC)
NSF/ANSI2
Standards
•
NSF/ANSI2
Standards
2012 International Mechanical Code (IMC)
•
2012
Code
(IMC)
2012 International
International Mechanical
Fuel Gas Code
(IFGC)
•
2012
GasConservation
Code (IFGC)Code (IECC)
2012 International
International Fuel
Energy
•
2012
Energy
Conservation
2012 International
Life Safety Code
– NFPA
101(LSC)Code (IECC)
•
2012
Safety
Code Code
– NFPA
101(LSC)
2011 Life
National
Electric
– NFPA
70 (NEC)
•
2011
National
Electric Code
70 (NEC)
Maryland
Accessibility
Code –– NFPA
ADAAG/2010
•
Maryland
Accessibility
Code
ADAAG/2010
Fire Safety
Codes - The
Fire –Safety
Code of Montgomery
•
Fire
Safety
Codes -as
The
Fire Safety
Code of
County,
Maryland,
it existed
on August
1, Montgomery
1996,
County,
Maryland,
it existed
on August
1, 1996,
being Chapter
22 ofasthe
Montgomery
County
Code, 1984
being
Chapter
22
of
the
Montgomery
County
Code,
1984
(1994 Replacement Volume), the 2012 Editions of the
(1994
Replacement
Volume),
the 2012
Editions
the
National
Fire Protection
Association
Uniform
FireofCode
National
Fire
Protection
Association
Uniform
Fire
Code
(NFPA 1) and Life Safety Code® (NFPA 101®), all
(NFPA
1) and
Life codes
Safetyor
Code®
(NFPA
101®), all by
associated
NFPA
standards
incorporated
associated
NFPA
codes
or
standards
incorporated
by
reference, and the latest editions of certain other NFPA
reference,
and the latestby
editions
of certain
other1 NFPA
codes not incorporated
reference
into NFPA
or NFPA
codes
101® not incorporated by reference into NFPA 1 or NFPA
101®
APPROVING AUTHORITY:
APPROVING
AUTHORITY:
City of Gaithersburg
City
of Gaithersburg
Planning
and Code Administration
Planning
andInspections
Code Administration
Permits and
Permits
and Inspections
31 S. Summit
Ave.
31
S.
Summit
Ave.
Gaithersburg, MD 20877
Gaithersburg,
301-258-6330MD 20877
301-258-6330
301-258-6336 (fax)
301-258-6336 (fax)
•
Plumbing and natural gas
•
Plumbing
Plumbing and
and natural
natural gas
are under the authority of the
Plumbing
andSuburban
natural are
under Commission
the authority (WSSC),
of the
Washington
Sanitary
which
Washington
Suburban
Commission
(WSSC),
which
currently uses
the 2012Sanitary
International
Plumbing
Code (IPC)
currently
usesInternational
the 2012 International
Plumbing
Code (IPC)
and the 2012
Fuel Gas Code
(IFGC)
and the 2012 International Fuel Gas Code (IFGC)
•
Health review, when required, is performed by the
•
Health
review,County
when required,
is performed
by the
Montgomery
Department
of Health and
Human
Montgomery
County Department
of Health and Human
Services, Regulatory
Division - 240-777-398
Services, Regulatory Division - 240-777-398
DEMOLITION NOTE NUMBER
DEMOLITION NOTE NUMBER
NEW CONSTRUCTION NOTE NUMBER
NEW CONSTRUCTION NOTE NUMBER
SPECIFICATION SECTION
SPECIFICATION
SECTION
SHELF ANGLE
SHELF ANGLE
SPECIFIED ITEM
SPECIFIED ITEM
TOILET ACCESSORY NUMBER
TOILET ACCESSORY NUMBER
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
No.
Date
Revisions
Drawing Title
GENERAL NOTES,
ABBREVIATIONS & SYMBOLS
Phase
CONCEPT
A/E Project Number
12-0009.015
Date
CORNER GUARD NUMBER
CORNER
GUARD
NUMBER
CRASH RAIL
NUMBER
CRASH RAIL NUMBER
HAND RAIL NUMBER
HAND RAIL NUMBER
Description
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
1:1
Number
A002
SCALE: 1-1/2" = 1'-0"
2'
1'
0
SCALE: 1" = 1'-0"
2'
1'
0 1/2'
3'
SCALE: 3/4" = 1'-0"
2'
1'
0
SCALE: 1/2" = 1'-0"
4'
2'
1'
0
SCALE: 1/4" = 1'-0"
8'
4'
2'
0
SCALE: 3/16" = 1'-0"
12'
8'
4'
ARCHITECTURAL:
ELECTRICAL:
MECHANICAL:
PLUMBING
STORAGE ROOM:
1.
FIRE RATED DOOR AND HARDWARE
2.
VCT FLOOR TILE PRODUCT DATA AND
SAMPLE
3.
FLOORING TRANSITION
CONFERENCE ROOM:
1.
FIRE RATED DOOR AND HARDWARE
2.
CONFERENCE TABLE
3.
SIX(6) CONFERENCE CHAIRS
4.
CABINETS PRODUCT DATA AND SAMPLE
5.
CARPET PRODUCT DATA AND SAMPLE
6.
SUSPENDED CEILING SYSTEM
7.
WALL PAINT
8.
QUARTZ BASED COUNTERTOP
MATERIAL PRODUCT DATA AND SAMPLE
9.
FLOORING TRANSITIONS
BATHROOM:
1.
DOOR
2.
CEILING SYSTEM
3.
WALL TILE PRODUCT DATA AND SAMPLE
4.
VCT FLOOR TILE PRODUCT DATA AND
SAMPLE
5.
MIRROR
6.
SOAP DISPENSER
7.
TOILET PAPER HOLDER
8.
SANITARY NAPKIN DISPOSAL
9.
FLOORING TRANSITIONS
KITCHEN:
1.
STAINLESS STEEL ISLAND TABLE
2.
STAINLESS STEEL L TABLE
3.
REFRIGERATOR
4.
FREEZER
5.
SUSPENDED CEILING SYSTEM
6.
WALL TILE PRODUCT DATA AND SAMPLE
7.
FLOOR TILE PRODUCT DATA AND
SAMPLE
8.
FLOORING TRANSITIONS
9.
ROOF CURB SHOP DRAWINGS
10.
SHEET METAL
LOADING DOCK (NEXT TO KITCHEN)
1.
SUSPENDED CEILING SYSTEM
2.
FLOORING TRANSITIONS
TEEN ROOM:
1.
ACOUSTIC CEILING BAFFLES
2.
WALL AND CEILING PAINT
DANCE STUDIO:
1.
ACOUSTIC CEILING BAFFLES
2.
WALL AND CEILING PAINT
MULTIPURPOSE ROOM:
1.
SUSPENDED CEILING SYSTEM
2.
WALL PAINT
3.
CARPET
4.
FLOORING TRANSITIONS
ROOMS A, B & C
1.
FLOOR TILE PRODUCT DATA AND
SAMPLE
2.
FLOORING TRANSITIONS
1.
ELECTRICAL DEVICES
2.
ELECTRICAL EQUIPMENT (PANELS, DISCONNECTS, MOTOR
RATES SWITCHES)
3.
WIRING, CONDUITS, AND FITTINGS
4.
LIGHT FIXTURES
5.
COMMON ELECTRICAL MATERIALS (JUNCTION BOXES,
SUPPORTS, FITTINGS, ETC.)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
KITCHEN
1.
THREE COMPARTMENT SINK
2.
GREASE INTERCEPTOR
3.
ICEMAKER
4.
COMMERCIAL DISHWASHER
5.
HAND SINK
6.
MOPE SINK
7.
PVC DRAIN AND VENT PIPE
8.
CPVC WATER PIPE
STORAGE
1.
WASHER/DRYER
2.
WATER CLOSET
3.
LAVATORY
SPLIT SYSTEM
ERU
ELECTRICAL HEATING COIL
EXHAUST FAN
MAKE UP FAN
CABINET UNIT HEATERS
DUCTWORK SHOP DRAWINGS AND PRODUCT DATA
SYSTEM LAYOUT FIELD COORDINATION SHOP DRAWING
CONTROLS AND TAB SETTINGS
SEQUENCE OF OPERATIONS
TAB REPORT
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
No.
Description
Date
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
THE FOLLOWING LIST INFORMS OF THE ESSENTIAL TECHNICAL SUBMITTALS REQUIRED AT MINIMUM. HOWEVER, THE CONTRACTOR
SHALL BE RESPONSIBLE TO PROVIDE ALL RELEVANT SUBMITTALS FOR THE ENTIRE PROJECT'S PROCUREMENT. PROVIDE
CALCULATIONS AS NECESSARY. IN ADDITION, PROVIDE ADMINISTRATIVE SUBMITTAL AS REQUIRED BY THE SOLICITATION.
Revisions
Drawing Title
LIST OF REQUIRED
SUBMITTALS
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
LIST OF REQUIRED SUBMITTALS
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
1:1
Number
A003
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
SCALE: 1" = 1'-0"
1'
A200
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
3
2
A400
2
4
A401
KITCHEN
1
3'
0 1/2'
4
20' - 4"
LOADING
DOCK
1
NIKA A+E
UP
SCALE: 3/4" = 1'-0"
1'
2'
ROOM C
6
6
A401
4'
0
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
ROOM A
ROOM B
7
UP
SCALE: 1/2" = 1'-0"
0
1'
2'
5
MAIN LOBBY
SCALE: 1/4" = 1'-0"
1
A400
A600
5
A401
9
6
SCALE: 3/16" = 1'-0"
8'
4'
0
3
A400
A300
16'
SCALE: 1/8" = 1'-0"
8'
2
9
3
8
OFFICE
Revisions
Drawing Title
SCOPE OF WORK
FIRST FLOOR OVERALL PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
MECHANICALELECTRICAL
ROOM
1
A201
Description
OFFICE
CONFERNECE
ROOM
4
4'
CORRIDOR
No.
STORAGE ROOM
0
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
UP
12'
0
2'
4'
8'
10
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
A100
FIRST FLOOR OVERALL PLAN
E
W
3/16" = 1'-0"
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
1
100%
1:1
Number
A100
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
SCALE: 1" = 1'-0"
1'
0 1/2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
2
3'
A300
3
NIKA A+E
A300
SCALE: 3/4" = 1'-0"
UP
DN
1
A407
RCP
SCALE: 1/2" = 1'-0"
DANCE STUDIO
TEEN ROOM
9
UP
E
1
A406
RCP
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
4'
0
1'
2'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/16" = 1'-0"
No.
Description
Date
ROOM F
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
UP
Revisions
1
A403
F
Drawing Title
SCOPE OF WORK
SECOND FLOOR OVERALL
PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
1
A300
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
A101
SECOND FLOOR OVERALL PLAN
E
W
3/16" = 1'-0"
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
1
100%
1:1
Number
A101
SCALE: 1-1/2" = 1'-0"
1'
2'
NEW
EXHAUST FAN
OVER
EXISTING
ROOF CURB
GOOSENECKAIR INTAKE
1. ANY EXISTING ROOF AND ROOFING WARRANTY MUST BE
MAINTAINED DURING AND AFTER CONSTRUCTION. FLASH AND
COUNTERFLASH THE ENTIRE INSTALLATION THROUGHOUT.
2. ALL ROOF WORK SHALL BE PERFORMED BY A QUALIFIED ROOFING
INSTALLER.
3. PROCURE THE ROOF CURB WITH THE SAME MATERIAL AS THE
EXISTING STANDING SEAM METAL ROOF. INSTALL PER
MANUFACTURER'S INSTRUCTION.
4. ALL METAL TO METAL LAP CONNECTIONS WILL BE WEATHER SEALED
WITH MASTIC TAPE AND BUTYL CAULKING ALL AROUND. ALL
INSTALLATIONS WILL BE MECHANICALLY FASTENED.
SCALE: 1" = 1'-0"
0 1/2'
1'
2'
0
NOTES:
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
BIRD SCREEN
5. ORDER THE CURB WITH CONSIDERATIONS OF DUCT SIZE,
REQUIRED CLERANCES, HEIGHT ABOVE ROOF AND ROOF PITCH.
PROVIDE SHOP DRAWINGS FOR REVIEW.
GOOSENECK AIR INTAKE. SEE MECH. FOR DUCT SIZE
6. BIRD SCREEN MUST BE PROVIDED FOR GOOSENECK INTAKE
METAL DIVERTER CRICKET
Sim
DUCT FLANGE. MECHANICALLY TIE-IN WITH WOOD NAILER.
INSTALL RIB COVER WHERE RIB IS CUT. WATER BLOCK WITH BUTYL
CAULK AND MASTIC TAPE. MECHANICALLY FASTEN.
CURB METAL FLASHING TO BE NOTCHED 3" MIN. AT RIB CUT LOCATION
MANUFACTURER REQD.
CLEARANCE (TYP.)
SCALE: 3/4" = 1'-0"
2'
1'
0
4'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
DO NOT CUT
EXISTING
STRUCTURE AT
ANY PLACE.
DUCT. REFER TO MECHANICAL DRAWINGS.
NEW STRUCTURAL FRAMING
UNDER ROOF CUT LOCATION.
SECURE AND INTEGRATE WITH
EXISTING STRUCTURAL FRAMING.
SCALE: 1/2" = 1'-0"
2'
1'
INSTALL MANUFACTURER RECOMMENDED INSULATED, AND FULLY
WELDED ON ALL FOUR SIDE, CURB SUPPORT. CURB MATERIAL WILL BE
G-90 GALVANIZED STEEL OR 0.064 IN. ALUMINUM - DESIGNED FOR
PITCHED ROOFS.
INSTALL RIB COVER WHERE RIB IS CUT. WATER BLOCK WITH BUTYL
CAULK AND MASTIC TAPE. MECHANICALLY FASTEN.
CURB METAL FLASHING TO BE NOTCHED 3" MIN. AT RIB CUT LOCATION
EXISTING STANDING SEAM MTL. ROOF
ON 4" RIGID INSUL. w/ AIR
BARRIER ON MTL. DECK
FIRESTOP
AT ALL GAPS
AS REQD.
CROSS SECTION VIEW AT NEW EXHAUST FAN CURB
8'
0
NIKA A+E
SNAP COUNTERFLASHING ALL AROUND. ATTACH TO 2" WOOD NAILER
PROVIDED ON TOP OF CURB SUPPORT.
14" (HT)
3'
2
A102
SLOPE
ROOF PANELS
3" PANEL LAP
SCALE: 1/4" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
CURB TOP NAILER
DUCT
SCALE: 3/16" = 1'-0"
No.
2
A102
SCALE: 1/8" = 1'-0"
8'
4'
0
Description
GOOSENECK DETAIL
1" = 1'-0"
Revisions
1
A102
ROOF PLAN
Drawing Title
SCOPE OF WORK
1/8" = 1'-0"
ROOF OVERALL PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
ROOF PLAN VIEW AT NEW GOOSENECK AIR INTAKE
16'
0
4'
8'
12'
0
2'
4'
CLEARANCE
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A102
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
0
8' - 6"
SCALE: 3/4" = 1'-0"
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1'
3'
SCALE: 1" = 1'-0"
1'
COORDINATE STAGING AREA WITH PROGRAM DIRECTOR
2'
0 1/2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
COVER ALL PIPES IN
THIS AREA. SEE A401
SCALE: 1/2" = 1'-0"
A201
8'
0
1'
2'
4'
UP
8
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
SCALE: 1/4" = 1'-0"
NEW LIGHT POLE
NEW
EXISTING
FENCED MECHANICAL
YARD
SCALE: 3/16" = 1'-0"
1
A103
SITE PLAN
No.
3/64" = 1'-0"
Description
Date
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
9
Revisions
Drawing Title
SCOPE OF WORK
SITE PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
1:1
Drawn By
Author
Checked By
Checker
Sheet
E
100%
Number
A103
2'
#
1. INSTALL NEW ICEMAKER
Sim
2. INSTALL NEW TABLE
SCALE: 1-1/2" = 1'-0"
0
1'
7
A600
3. INSTALL NEW REFRIGERATOR/FREEZER
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
4. INSTALL NEW DISHWASHER
8' - 0"
2'
8' - 0"
5. INSTALL NEW KITCHEN TABLE WITH SINKS
AND FLANGE FEET (ACCESSORY S-31)
6. INSTALL NEW DOOR. SEE A600
SCALE: 1" = 1'-0"
0 1/2'
1'
7. REINSTALL STOVE, RANGE AND HOOD
AFTER COMPLETING CONSTRUCTION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
8. INSTALL NEW PEDESTAL HAND SINK
7
3
6
4
5
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
0
1
A200
KITCHEN SOUTH
3
1/2" = 1'-0"
A200
KITCHEN WEST
1/2" = 1'-0"
SCALE: 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
8' - 0"
Sim
8' - 0"
SCALE: 3/16" = 1'-0"
6
A600
No.
Description
Date
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
8
2'
1
5
6
2
2
1
Revisions
SCALE: 1/8" = 1'-0"
0
4'
8'
4
Drawing Title
SCOPE OF WORK
FIRST FLOOR ELEVATION
KITCHEN
Phase
32'
CONCEPT
A/E Project Number
SCALE: 1/16" = 1'-0"
8'
16'
2
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
NEW CONSTRUCTION LEGEND
A200
KITCHEN NORTH
1/2" = 1'-0"
4
A200
KITCHEN EAST
12-0009.015
Date
1/2" = 1'-0"
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A200
NEW CONSTRUCTION LEGEND
A300
#
1. INSTALL NEW DOOR
100
3. INSTALL NEW BASE CABINETS
8
A201
Sim
9
CASEWORK DETAIL
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
1/2" = 1'-0"
DUPONT ZODIAQ
QUARTZ CONTERTOP
1
2
3
3
2
1' - 3"
1
3
1/2" = 1'-0"
A201
2' - 0"
2' - 0"
2' - 0"
2' - 0"
2' - 0"
CONFERENCE WEST
1/2" = 1'-0"
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
0
2' - 11"
NIKA A+E
1'
3'
A201
CONFERENCE SOUTH
2' - 0"
2'
SCALE: 1" = 1'-0"
1'
A201
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
2' - 11"
90
Sim
0' - 4"
5
A600
2. INSTALL NEW CONFERENCE TABLE AND
CHAIRS
0' - 1"
8' - 0"
Sim
8' - 0"
SCALE: 1-1/2" = 1'-0"
3
A600
2'
0
1'
2' - 0"
TECHLINE CASEWORK
B332-24-35-24-9-2-W15
B332-24-35-24-9-2-W15
B430-24-35-24-9-0-W15
B430-24-35-24-9-0-W15
B129-24-35-24-9-0-W15
B129-24-35-24-9-1-W15
B332-15-35-24-9-0-W15
SCALE: 1/2" = 1'-0"
8' - 0"
8
9
A201
A201
Sim
CASEWORK FRONT DETAIL
TECHLINE HARDWARE
1/2" = 1'-0"
PULL:
0161-0154000000
SLIMLINE 128 PULL
MATTE NICKEL FINISH
HINGE:
0361-0093000000
CONCEALED HINGE
8'
0
1'
2'
8' - 0"
4'
TRANSITION BETWEEN EXISTING AND
NEW WALL MUST BE SEAMLESS
SCALE: 1/4" = 1'-0"
2
A201
2
2
CONFERENCE NORTH
4
1/2" = 1'-0"
A201
DRAWER SLIDES:
0461-0673000000
24" DEEP SLIDES
CONFERENCE EAST
1/2" = 1'-0"
ROLLER CATCH:
0261-1410000000
PART 1
0263-1398000000
PART 2
12'
0
2'
4'
3
LOCK:
TO MATCH CABINET
TYPE AND PULL FINISH
5
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
SCALE: 3/16" = 1'-0"
EXISTING R.O.
HEIGHT
3' - 0"
EXISTING
V.I.F.
Description
Date
V.I.F.
EXISTING
V.I.F.
V.I.F.
No.
EXISTING R.O.
EDGE
V.I.F.
7' - 3" V.I.F.
7' - 0" V.I.F.
4' - 1 1/4"
Revisions
Drawing Title
SCOPE OF WORK
FIRST FLOOR ELEVATION
CONFERENCE ROOM AND
ENTRIES
2' - 0"
KK
2' - 0"
3' - 0" V.I.F.
KK
2' - 0"
3' - 0"
120
2' - 6"
2' - 6"
3' - 0"
110
7' - 0" V.I.F.
4' - 1 1/4"
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
A300
Phase
32'
CONCEPT
NEW DOOR HARDWARE
FIRST FLOOR
0' - 0"
NEW DOOR HARDWARE
FIRST FLOOR
0' - 0"
FIRST FLOOR
0' - 0"
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
6
S
5
A201
SOUTH ENTRY
3/8" = 1'-0"
6
A201
NORTH ENTRY
3/8" = 1'-0"
7
A201
LOBBY WINDOW
1/2" = 1'-0"
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A201
SCALE: 1-1/2" = 1'-0"
2'
NEW SCREW CONNECTING CHANNEL TO RAFTER
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
SCALE: 1" = 1'-0"
CEILING FINISH
5' - 3"
1'
0
0 1/2'
1'
2'
EXISTING HORIZONTAL ROOF RAFTER
NEW FINISHED STEEL CHANNEL
3'
BOLT WITH NUT THROUGH CHANNEL
NIKA A+E
2' - 0"
NEW CABLE WITH EYE LOOP ON EACH END (KIT)
NEW EYE LOOP CARABINER (KIT)
SCALE: 3/4" = 1'-0"
1'
2'
EYE HOOK MOUNTING BRACKET (KIT)
SOUNDSOAK BAFFLE 2X4 (KIT)
TEEN ROOM
4
A300
4'
0
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
BAFFLE CONNECTION DETAIL
3" = 1'-0"
5
ENTRY
A300
3/8" = 1'-0"
FF
SCALE: 1/2" = 1'-0"
NEW LINTEL. 2 STEEL ANGLES 5X3-1/2X1/4
(LLV) @ EACH SIDE OF NEW OPENING
2
A300
TEEN ROOM SECTION
6
Sim
A300
3/8" = 1'-0"
0' - 8" MIN
OPENING
NAILER
SECURED TO
CMU
R.O. HEIGHT
STEEL ANGLE 5X3-1/2X1/4
6' - 8 1/2"
R.O. HEIGHT
NEW OPENING
LESS THAN 4' WIDE
DRYWALL WRAP UNDER STEEL ANGLE
12'
METAL DOOR
FRAME NAILER
SEAL AROUND DOOR FRAME
NEW DOOR. SEE A600 FOR HEIGHT
SCALE: 3/16" = 1'-0"
4'
8'
4
A300
6
A300
CONFERENCE DOOR LINTEL DETAIL
7
1" = 1'-0"
A300
CONFERENCE DOOR STRUCTURE
No.
1/2" = 1'-0"
Description
Date
DANCE STUDIO
SCALE: 1/8" = 1'-0"
0
0' - 0"
Revisions
10' - 5 1/2"
Drawing Title
SCOPE OF WORK
7' - 3 1/4"
4'
8'
16'
0
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
EXISTING FURRING
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
11' - 7 1/2"
ROOM SECTIONS AND
DETAILS
ROOM F
Phase
32'
CONCEPT
FF
FF
11' - 7 1/2"
A/E Project Number
12-0009.015
11' - 7 1/2"
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
S
3
A300
DANCE STUDIO SECTION
3/8" = 1'-0"
1
A300
ROOM F SECTION
3/8" = 1'-0"
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A300
R.O.
R.O.FOR
FOR3'3'--0"
0"xx6'-8"
6'-8" DOOR
DOORIN
IN
EXIST.CMU
EXIST.CMUWALL
WALL -- INSTALL
INSTALLNEW
NEWLINTEL
LINTEL
DEMOLITION
GENERAL NOTES
DEMOLITION GENERAL
NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE
APPLICABLE LOCAL CODE REGULATIONS AND
ORDINANCES.
ORDINANCES.
6
6
66
9
9
15
CORRIDOR
CORRIDOR
2. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH THE LATEST EDITION OF THE
OCCUPATIONAL
OCCUPATIONAL SAFETY AND HEALTH
HEALTH ACT (OSHA).
3. ALL SLAB PENETRATIONS
PENETRATIONS TO
TO BE
BE FILLED & PREPARED
PREPARED FOR NEW FINISHES AS REQUIRED.
SCALE: 1-1/2" = 1'-0"
0
1'
66
4. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO START
OF WORK.
WORK.
17
17
16
16
APARTMENT
APARTMENT
55
14
14
6. COORDINATE WITH ELECTRICAL DRAWINGS FOR REMOVAL OF LIGHT FIXTURES, SWITCHES,
CONDUIT,
CONDUIT, AND RELATED
RELATED WIRING AND SUPPORT SYSTEMS.
SYSTEMS. (TYP.)
55
2'
7. COORDINATE WITH PLUMBING DRAWINGS FOR LOCATIONS OF EXISTING
EXISTING FLOOR
FLOOR PENETRATIONS
PENETRATIONS TO
BE PATCHED
AND
LOCATIONS
OF
NEW
FLOOR
PENETRATIONS
FOR
SENTRY
LINES.
PATCHED AND LOCATIONS OF NEW
SCALE: 1" = 1'-0"
1'
0 1/2'
8. COORDINATE WITH FINISH & EQUIPMENT
EQUIPMENT PLAN TO PROVIDE ADDITIONAL BLOCKING FOR LOCATIONS
OF WALL MOUNTED
MOUNTED ITEMS.
OFFICE
OFFICE
22
55
9. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING, SUPPORT
SUPPORT AND PROTECTION OF
EXISTING CONSTRUCTION
TO
REMAIN
DURING
DEMOLITION
AND
NEW
CONSTRUCTION.
CONSTRUCTION TO REMAIN
A201
A201 88
99
10. AFTER DEMOLITION, CONTRACTOR TO FUR AND PATCH ALL
ALL FINISHES,
FINISHES, WALL CLADDINGS, WALL
PENETRATIONS,
PENETRATIONS, FIRE
FIRE SEPARATIONS, WEATHERPROOFING AND REPAIR ALL DAMAGES CAUSED TO
EXISTING
BUILDING
DURING DEMOLITION PROCESS AS REQUIRED.
EXISTING
3'
OFFICE
OFFICE
22
2'
SCALE: 3/4" = 1'-0"
1'
DEMOLITION
DEMOLITION KEY
KEY NOTES
NOTES
APARTMENT
APARTMENTAND
ANDBATHROOM
BATHROOM PLAN
PLAN-- ENLARGED
ENLARGED--DEMOLITION
DEMOLITION
SCALE: 1/2" = 1'-0"
3/8"
3/8"==1'-0"
1'-0"
11. REMOVE (SCRAP) EXISTING GREASE INTERCEPTOR
12. REMOVE (SCRAP) EXISTING HAND-WASH SINK
15
13. REMOVE (SCRAP) EXISTING DISHWASHER
14. REMOVE EXISTING
EXISTING ELECTRICAL PANEL.
PANEL. REFER
REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
15. SAW CUT AND REMOVE EXTENT OF EXISTING SLAB-ON-GRADE FOR NEW PLUMBING PIPES. REFER TO
PLUMBING
PLUMBING DRAWINGS
DRAWINGS FOR
FOR ADDITIONAL INFORMATION. FIELD COORDINATE LAYOUT.
16. REMOVE (SCRAP) EXISTING PLUMBING FIXTURES.
SCALE: 1/4" = 1'-0"
4'
2'
33
EXISTING W/D
W/D AND
AND SAFELY STORE AWAY FOR REUSE.
17. REMOVE EXISTING
18. REMOVE EXISTING AIR CONDITIONING UNITS. FILL AND
AND FINISH
FINISH ROUGH
ROUGH OPENING
OPENING TO MATCH
MATCH EXTERIOR AND
INTERIOR
FINISH.
INTERIOR
---
MAIN
LOBBY
12'
0
14
14
SCALE: 3/16" = 1'-0"
12
12
8'
#
1. REMOVE (SCRAP) EXISTING
EXISTING WINDOW
WINDOW AND FRAMING. SAW CUT AND REMOVE CMU WALL BELOW FROM
SILL TO FLOOR WITHIN WINDOW R.O. WIDTH
WIDTH EXTENTS
EXTENTS
2. REMOVE (SCRAP) EXISTING FLOORING, UNDERLAYMENT AND ADHESIVE DOWN TO EXISTING SLAB.
PREPARE
PREPARE SUBSTRATE
SUBSTRATE SURFACE
SURFACE TO
TO RECEIVE
RECEIVE NEW
NEW FLOORING. REMOVE EXISTING CEILING AND FIXTURES.
REMOVE
PREPARE SURFACES
REMOVE ALL
ALL WALL
WALL TILES IN KITCHEN. PREPARE
SURFACES TO RECEIVE NEW
NEW WALL TILES.
3. SAFELY STORE REFRIGERATOR/FREEZER FOR RELOCATION
4. REMOVE (SCRAP) METAL KITCHEN COUNTERS AND SINKS.
5. REMOVE (SCRAP) DOOR AND HARDWARE
6. REMOVE EXISTING WALL
7. REMOVE (SCRAP) EXISTING KITCHENETTE, FLOOR AND OVERHEAD CABINETS. CAP EXISTING PLUMING
AT SINK. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
8. REMOVE REFRIGERATOR IN EXISTING APARTMENT AND STORE TEMPORARILY
9. REMOVE (SCRAP) BATHTUB.
BATHTUB. CAP EXISTING PLUMBING.
PLUMBING. REFER TO PLUMBING FOR ADDITIONAL
INFORMATION.
10. REMOVE (SCRAP) EXISTING ICEMAKER.
15
4'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
12. TEMPORARY
TEMPORARY STORAGE FOR EXISTING
EXISTING EQUIPMENT
EQUIPMENT WILL
WILL BE SPECIFIED BY THE CITY
18
18
8'
0
1'
2'
4'
0
---
33
NIKA A+E
11. CONTRACTOR SHALL INSTALL TEMPORARY CNSTRUCTION PARTITION TO PREVENT
PREVENT ANY
DISRUPTION TO OCCUPIED SPACES THROUGHOUT CONSTRUCTION.
-
A400
A400
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
8. KEY NOTES ARE PROVIDED FOR ADDITIONAL CLARITY OF BUILDING
BUILDING CONDITIONS
CONDITIONS AND
AND SHALL NOT
LIMIT THE OVERALL
OVERALL SCOPE
SCOPE OF
OF WORK.
WORK.
66
0
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
5. COORDINATE WITH MECHANICAL DRAWINGS FOR REMOVAL OF DUCTS, VENTS, RADIATORS,
REGISTERS/DIFFUSERS, WINDOW A/C UNITS
UNITS AND
AND SUPPORT SYSTEMS. (TYP.)
77
88
1
A201
7
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
LOADING
LOADING
DOCK
DOCK
66
No.
13
13
KITCHEN
KITCHEN
Description
Date
22
55
16'
10
10
11
SCALE: 1/8" = 1'-0"
0
4'
8'
44
11
11
-
1
---
A400
A400
ENTRANCE - ENLARGED
Revisions
1'-0"
3/8" = 1'-0"
Drawing Title
SCOPE OF WORK
FIRST FLOOR ENLARGED
PLANS - DEMOLITION
11
11
Phase
CONCEPT
32'
55
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
0'0'--3"
3"MIN
MIN
ROOMAA
ROOM
S
22
A400
A400
KITCHENPLAN
PLAN--ENLARGED
ENLARGED--DEMOLITION
DEMOLITION
KITCHEN
3/8"==1'-0"
1'-0"
3/8"
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A400
2'
2'
MIN
MIN
16
16
TOILET
TOILET
12
12
12
10
10
14
14
14
ALIGN
ALIGN
-
12
12
12
5. NEW
STAINLESS
STEEL
(SS)(SS)
PREPARATION
COUNTER
WITH
STORAGE
5.
NEW
STAINLESS
STEEL
PREPARATION
COUNTER
WITH
STORAGE
11
11
33
100
100
-
111
6.
NEW
DISHWASHER
WITH
VENT
EXHAUST.
REFER
PLUMBING
AND
6. NEW
DISHWASHER
WITH
VENT
EXHAUST.
REFER
TO TO
PLUMBING
AND
ELECTRICAL
ELECTRICAL
DRAWINGS
FR
ADDITIONAL
INFORMATION.
DRAWINGS FR ADDITIONAL INFORMATION.
11
CONFERENCE
CONFERENCE
T3
T3
22
242
242SF
SF
0'0'- -2"
2"
2'
2'
EQ
ALIGN
ALIGN
ALIGN
17
17
17
12
12
OFFICE
OFFICE
22
SCALE:
1" =
SCALE: 1"
= 1'-0"
1'-0"
111
444 A201
38
3
38
A201 8
A201
219
219SF
SF
219
SF
99
2
2
29
6' - 0".
444
V.I.F.
STORAGE
STORAGE
STORAGE
EQ
EQ
16
16
13' --- 3
1/4"
13'
13'
33 1/4"
1/4"
18
18
18
3'
3'
OFFICE
OFFICE
6'
6' -- 0".
0".
EQ
SCALE: 3/4"
3/4" =
= 1'-0"
1'-0"
SCALE:
2'
2'
4
SCALE:
= 1'-0"
1'-0"
SCALE: 1/2"
1/2" =
CONFERENCE
CONFERENCEROOM
ROOMAND
ANDOFFICES
OFFICES--ENLARGED
ENLARGED
3/8" = 1'-0"
21.
4
A401
SOUTH
STOREFRONT ENTRY DOOR
10
3/8" = 1'-0"
414 SF
19
MAIN LOBBY
3' - 0 1/2" +/- V.I.F
10
414 SF
SCALE:
SCALE: 1/4"
1/4" =
= 1'-0"
1'-0"
4'
4'
2'
2'
EXISTING OVERHEAD EXHAUST HOOD AND STOVE TO BE REINSTALLED IN
SAME LOCATION. EXHAUST HOOD STERLING EQUIPMENT CO., INC.
19
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
3' - 0 1/2" +/- V.I.F
3
A401
MAIN LOBBY ENTRANCE - ENLARGED
3/8" = 1'-0"
12'
12'
0
0
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
MAIN LOBBY
3/8"
3/8"===1'-0"
1'-0"
3/8"
1'-0"
8'
8'
0
0
1'
1'
2'
2'
22
A401
A401
A401
NIKA A+E
16.
NEW QUARTZ
BASED WALLBOARD
COUNTERTOP
WITH BACKSPLASH
17. INSTALL
NEW GYPSUM
AROUND
NEW ELECTRICAL PANEL. PREPARE
WALL SURFACE TO RECEIVE NEW FINISH
17.
INSTALL NEW GYPSUM WALLBOARD AROUND NEW ELECTRICAL PANEL.
PREPARE
WALL SURFACE
TO CHAIRS
RECEIVE NEW FINISH
18. NEW
CONFERENCE
TABLE AND
SOUTH STOREFRONT ENTRY DOOR
4'
4'
A401
3
A401
MAIN LOBBY ENTRANCE - ENLARGED
3/8" = 1'-0"
EQ
SCALE: 3/16"
3/16" =
= 1'-0"
1'-0"
SCALE:
888
1B
1B
777
10
10
10
6' -EQ
0".
16'
16'
999
444
T4
T4
T5
KITCHEN
KITCHEN
KITCHEN
6
99
A401
111
6
66
319SF
SF
319
319
SF
33
6'EQ
- 0".
SCALE:
1/8" =
= 1'-0"
1'-0"
SCALE: 1/8"
4'
4'
8'
8'
222
555
V.I.F.
13
13
111
444 A200
A200 333
A200
EXISTING PIPES
AGAINST EXTERIOR
WALL
EXISTING
PIPES
AGAINST EXTERIOR
WALL
NEW METAL PIPE DUCT
No.
Description
-
A401
PIPE COVER PLAN DETAIL
NEW METAL PIPE DUCT
METAL PIPE COVER RUNNING LENGTH OF
PIPES, SECURED TO EXISTING WALL AND
PAINTED
TOCOVER
MATCHRUNNING
EXTERIORLENGTH
FINISH.OF
METAL
PIPE
COVER
IS
TO
BE
CAPPED
TO
PREVENT
PIPES, SECURED TO EXISTING WALL AND
RAIN PENETRATION
BUT ALLOW
FOR
PAINTED
TO MATCH EXTERIOR
FINISH.
PROPER
VENTILATION
OF
THE
CAVITY
COVER IS TO BE CAPPED TO PREVENT
RAIN PENETRATION BUT ALLOW FOR
PROPER VENTILATION OF THE CAVITY
Revisions
1/2" = 1'-0"
PIPE COVER PLAN DETAIL
1/2" = 1'-0"
Drawing Title
SCOPE OF
OF WORK
WORK
SCOPE
FIRST FLOOR ENLARGED
PLANS
---
T5
Phase
32'
32'
CONCEPT
A/E Project Number
12-0009.015
5
A401
Date
NORTH STOREFRONT ENTRY DOOR
EQ
SCALE:
SCALE: 1/16"
1/16" =
= 1'-0"
1'-0"
8'
8'
16'
16'
555
T4
T4
3/8" = 1'-0"
SS
13
13
13
A401
A401
A401
KITCHENPLAN
PLAN--ENLARGED
ENLARGED
KITCHEN
3/8"===1'-0"
1'-0"
3/8"
1'-0"
3/8"
35%
60%
90%
5
A401
NORTH STOREFRONT ENTRY DOOR
3/8" = 1'-0"
W
W
NN
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
EE
11
Date
LOADING
LOADINGDOCK
DOCK
21
21
V.I.F.
0
0
4'
4'
8'
8'
20
20
0
0
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
18.
NEW
CONFERENCE
TABLE AND
CHAIRS
19. NEW
ALUMINUM
STOREFRONT
WITH
THERMAL BREAK AND DOUBLE PANE INSULATED
GLAZING AT MAIN LOBBY. STOREFRONT WIDTH SHALL BE SAME AS EXISTING ROUGH
OPENING
19.
NEW ALUMINUM STOREFRONT WITH THERMAL BREAK AND DOUBLE PANE
INSULATED GLAZING AT MAIN LOBBY. STOREFRONT WIDTH SHALL BE SAME
20. REFILL
AREA WHERE
SLAB
WAS REMOVED WITH NEW SLAB AFTER INSTALLING
AS EXISTING
ROUGH
OPENING
EQUIPMENT
20.
REFILL AREA WHERE SLAB WAS REMOVED WITH NEW SLAB AFTER
INSTALLING EQUIPMENT
EQ
EQ
1'
1'
0
0
T5
13'
13'---4"
4"
13'
4"
7.
NEW
BEVERAGE AIR
MODEL:
HR1W-1S REFRIGERATOR AND NEW BEVERAGE
7. NEW
REFRIGERATOR
AND
FREEZER
AIR MODEL: HF1W-1S FREEZER
8. NEW HAND WASH PEDESTAL SINK
8.
NEW HAND WASH PEDESTAL SINK
9. NEW PEDESTAL MOP SINK
9.
NEW PEDESTAL MOP SINK
10. NEW W.C.
10.
NEW W.C.
11. NEW SINK
11.
NEW SINK
12. NEW FIRE RATED DOOR - 90 MINUTE
12.
NEW FIRE RATED DOOR - 90 MINUTE
13. NEW DOOR ASSEMBLEY
13.
NEW DOOR ASSEMBLEY
14. NEW LOCATION OF FREEZER/REFRIGERATOR RELOCATED FROM EXISTING KITCHEN
14.
NEW LOCATION OF FREEZER/REFRIGERATOR RELOCATED FROM EXISTING
15. NEW
LOCATION OF WASHER-DRYER.
KITCHEN
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
15.
NEW
LOCATION
OF COUNTERTOP
WASHER-DRYER.
16. NEW
QUARTZ
BASED
WITH BACKSPLASH
T5
V.I.F.
V.I.F.
1'
1'
3. NEW
STAINLESS
STEEL
(SS)(SS)
KITCHEN
COUNTER
WITH
THREE
BOWL
SINK
3.
NEW
STAINLESS
STEEL
KITCHEN
COUNTER
WITH
THREE
BOWL
SINK
T2
T2
15
15
15
0
1/2'
0 1/2'
2. NEW
BASE
CABINETS
WITH
LAMINATED
FINISH
2.
NEW
BASE
CABINETS
WITH
LAMINATED
FINISH
4. NEW
MOVABLE
STAINLESS
STEEL
(SS)(SS)
ISLAND
COUNTER
4.
NEW
MOVABLE
STAINLESS
STEEL
ISLAND
COUNTER
SCALE:
SCALE: 1-1/2"
1-1/2" =
= 1'-0"
1'-0"
0
0
1'
1'
T1
T1
T1
CORRIDOR
CORRIDOR
1'1'- -551/4"
1/4"
1'1'- -881/2"
1/2"
20
##
1.
NEW
PARTITION
WALL
1. NEW
PARTITION
WALL
6'6'- -001/2"
1/2"HOLD
HOLD
90
90
90
0
0
IF
IF THIS
THIS DRAWING
DRAWING IS
IS A
A REPRODUCTION,
REPRODUCTION, GRAPHIC
GRAPHIC SCALE
SCALE MUST
MUST BE
BE USED
USED
NEW
NEW WORK KEY NOTES
666
A300
A300
A300
1:1
Number
A401
2'
NOTES:
SCALE: 1-1/2" = 1'-0"
2. EXISTING SPRINKLERS THAT ARE
LOCATED WHERE NEW LIGHTS OR NEW
CEILING EQUIPMENT WILL REQUIRE
RELOCATION TO AN ADJACENT CEILING
TILE AND SHALL BE SPACED PER NFPA 13
REQUIREMENTS.
TOILET
3
CONFERENCE
2
STORAGE
8" MIN
1'
0
1. EXISTING FIRE SPRINKLERS WILL
REQUIRE THE DROP TO BE ADJUSTED
FOR THE NEW CEILING HEIGHTS.
J
J
SCALE: 1" = 1'-0"
0 1/2'
1'
J
4. EXISTING P.A. SYSTEM SPEAKERS AND
OCCUPANCY CENSORS TO BE
REINSTALLED AFTER CEILING
REPLACEMENT
OFFICE
A201
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
5. SEE MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION
1
4
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
3. ALL NEW SPRINKLER PIPING AND
EQUIPMENT SHALL BE TESTED PER NFPA
13 AND CITY OF GAITHERSBURG
REQUIREMENTS.
2'
4
3
FOR RCP LEGEND SEE SHEET A002
3'
2
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
4'
0
1'
2'
BULKHEAD
1
APARTMENT AND BATHROOM REFLECETED CEILING PLAN
SCALE: 1/2" = 1'-0"
3/8" = 1'-0"
SCALE: 1/4" = 1'-0"
5
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
A300
MAIN LOBBY
A201
10
7
SCALE: 3/16" = 1'-0"
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
A402
KITCHEN
LOADING DOCK
1
1B
No.
4
16'
A200
3
ENTRANCE REFLECTED CEILING PLAN
3/8" = 1'-0"
Revisions
Drawing Title
SCOPE OF WORK
FIRST FLOOR ENLARGED
REFLECTED CEILING PLANS
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
3
A402
SCALE: 1/8" = 1'-0"
8'
4'
0
Description
1
2
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
6
A300
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
A402
KITCHEN REFLECTED CEILING PLAN
E
W
3/8" = 1'-0"
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
2
100%
1:1
Number
A402
#
SCALE: 1-1/2" = 1'-0"
NEW WORK KEY NOTE
#
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
1. INSTALL NEW FLOOR FINISH, REFINISH GYP. BD,
PAINT FINISH AND SUSPENDED CEILING SYSTEM.
SCALE: 1" = 1'-0"
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
ROOM F
1
F
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1
A300
SCALE: 1/2" = 1'-0"
1
A403
COMPUTER ROOM "ROOM F" - ENLARGED DEMOLITION
3/8" = 1'-0"
SCALE: 1/4" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
SCALE: 3/16" = 1'-0"
No.
TELECOM
EQUIPMENT
RM
1
Description
Date
ROOM F
F
Revisions
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
TELECOM
EQUIPMENT
RM
2'
0 1/2'
1'
2'
0
1'
1. REMOVE EXISTING FLOOR FINISH, WALL
COVERING AND SUSPENDED CEILING SYSTEM.
Drawing Title
SCOPE OF WORK
SECOND FLOOR ENLARGED
PLAN - COMPUTER ROOM F DEMOLITION AND NEW WORK
Phase
CONCEPT
32'
1
A300
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
DEMOLITION KEY NOTE
2
A403
COMPUTER ROOM "ROOM F" - ENLARGED
S
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
Drawn By
PG
Checked By
AV
3/8" = 1'-0"
Sheet
E
W
N
CADD Plot Scale
Revit Model
1:1
Number
A403
2'
1'
SCALE: 1-1/2" = 1'-0"
2. EXISTING SPRINKLERS THAT ARE
LOCATED WHERE NEW LIGHTS OR NEW
CEILING EQUIPMENT WILL REQUIRE
RELOCATION TO AN ADJACENT CEILING
TILE AND SHALL BE SPACED PER NFPA
13 REQUIREMENTS.
4. EXISTING P.A. SYSTEM SPEAKERS
AND OCCUPANCY CENSORS TO BE
REINSTALLED AFTER CEILING
REPLACEMENT
SCALE: 1" = 1'-0"
1'
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
3. ALL NEW SPRINKLER PIPING AND
EQUIPMENT SHALL BE TESTED PER
NFPA 13 AND CITY OF GAITHERSBURG
REQUIREMENTS.
2'
0
1. EXISTING FIRE SPRINKLERS WILL
REQUIRE THE DROP TO BE ADJUSTED
FOR THE NEW CEILING HEIGHTS.
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
5. SEE MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION
SCALE: 1/2" = 1'-0"
TELECOM
EQUIPMENT
RM
0
8'
0
1'
2'
4'
SCALE: 3/4" = 1'-0"
3'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1'
NIKA A+E
2'
FOR RCP LEGEND SEE SHEET A002
SCALE: 1/4" = 1'-0"
F
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
12'
0
2'
4'
ROOM F
1
SCALE: 3/16" = 1'-0"
No.
1
A405
Description
Date
COMPUTER ROOM "ROOM F" REFLECETED CEILING PLAN
3/8" = 1'-0"
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
A300
Revisions
Drawing Title
SCOPE OF WORK
SECOND FLOOR ENLARGED
REFLECTED CEILING PLAN ROOM F
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
NOTES:
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A405
2'
1'
SCALE: 1-1/2" = 1'-0"
2. EXISTING SPRINKLERS THAT ARE
LOCATED WHERE NEW LIGHTS OR NEW
CEILING EQUIPMENT WILL REQUIRE
RELOCATION TO AN ADJACENT CEILING
TILE AND SHALL BE SPACED PER NFPA
13 REQUIREMENTS.
4. EXISTING P.A. SYSTEM SPEAKERS AND
OCCUPANCY CENSORS TO BE
REINSTALLED AFTER CEILING
REPLACEMENT
SCALE: 1" = 1'-0"
1'
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
3. ALL NEW SPRINKLER PIPING AND
EQUIPMENT SHALL BE TESTED PER NFPA
13 AND CITY OF GAITHERSBURG
REQUIREMENTS.
2'
0
1. EXISTING FIRE SPRINKLERS WILL
REQUIRE THE DROP TO BE ADJUSTED
FOR THE NEW CEILING HEIGHTS.
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
5. SEE MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION
3'
FOR RCP LEGEND SEE SHEET A002
NIKA A+E
SPRINKLER CONE NOT TO BE OBSTRUCTED BY SUSPENDED BAFFLES
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
2
A300
SCALE: 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
PERPENDICULAR
OBSTRUCTION
NEGLIGIBLE
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
TEEN ROOM
E
SCALE: 3/16" = 1'-0"
No.
Description
Date
Revisions
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
1'
2'
SUSPENDED BAFFLE (TYP)
Drawing Title
SCOPE OF WORK
SECOND FLOOR ENLARGED
REFLECTED CEILING PLAN
-TEEN ROOM E
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
NOTES:
S
1
A406
TEEN ROOM "ROOM E" REFLECTED CEILING PLAN
3/8" = 1'-0"
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A406
2'
1'
SCALE: 1-1/2" = 1'-0"
2. EXISTING SPRINKLERS THAT ARE
LOCATED WHERE NEW LIGHTS OR NEW
CEILING EQUIPMENT WILL REQUIRE
RELOCATION TO AN ADJACENT CEILING
TILE AND SHALL BE SPACED PER NFPA 13
REQUIREMENTS.
4. EXISTING P.A. SYSTEM SPEAKERS AND
OCCUPANCY CENSORS TO BE
REINSTALLED AFTER CEILING
REPLACEMENT
SCALE: 1" = 1'-0"
1'
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
3. ALL NEW SPRINKLER PIPING AND
EQUIPMENT SHALL BE TESTED PER NFPA
13 AND CITY OF GAITHERSBURG
REQUIREMENTS.
2'
0
1. EXISTING FIRE SPRINKLERS WILL
REQUIRE THE DROP TO BE ADJUSTED
FOR THE NEW CEILING HEIGHTS.
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
5. SEE MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION
3'
NIKA A+E
2'
FOR RCP LEGEND SEE SHEET A002
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SPRINKLER CONE NOT TO BE OBSTRUCTED BY SUSPENDED BAFFLES
SCALE: 3/4" = 1'-0"
3
A300
SCALE: 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
DANCE STUDIO
9
SCALE: 3/16" = 1'-0"
4
Sim
No.
A300
Description
Date
Revisions
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
1'
SUSPENDED BAFFLE (TYP)
Drawing Title
SCOPE OF WORK
SECOND FLOOR ENLARGED
REFLECTED CEILING PLAN DANCE STUDIO
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
NOTES:
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
A407
DANCE STUDIO REFLECTED CEILING PLAN
E
W
3/8" = 1'-0"
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
1
100%
1:1
Number
A407
Fire
Room Name Room Wall Rating
STORAGE
SOUTH
60-MIN
CONFERENCE SOUTH
N/A
BATHROOM
NORTH
N/A
KITCHEN
NORTH
N/A
KITCHEN
WEST
N/A
NORTH ENTRY EAST
SOUTH ENTRY EAST
1
SCALE: 1-1/2" = 1'-0"
0
1'
KITCHEN
A201
Frame Type
METAL
METAL
WOOD
METAL
METAL
ALUMINUM
ALUMINUM
Frame Finish
PAINT1
PAINT1
PAINT1
PAINT1
PAINT1
DARK BRONZE
DARK BRONZE
Door Material
METAL
METAL
WOOD
METAL+LITE
METAL
GLASS
GLASS
ROOM FINISH SCHEDULE - FIRST FLOOR
Height
6' - 8"
6' - 8"
6' - 8"
6' - 8"
6' - 8"
7' - 0"
7' - 0"
Width
3' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
6' - 0"
6' - 0"
HW
HW 1
HW 2
HW 3
HW 4
HW 4
HW 5
HW 5
Transition
Type
T1 ALUM.
T2 ALUM.
T3 ALUM.
T4 ALUM.
T4 ALUM.
T5 ALUM.
T5 ALUM.
Transition From-To
VCT1-VCT2
CARPET-VCT1
CARPET-VCT2
TILE-LVT
TILE-LVT
VCT-CONCRETE
VCT-CONCRETE
2'
Key
SCALE: 1" = 1'-0"
ROOM A
ROOM B
5
7
ACT-PVC
M8206KL
ACT
MAIN LOBBY
10
3'
0 1/2'
1'
AQ220
1
1B
2
3
4
5
6
7
TOILET
Description
Manufacturer
UNGLAZED QUARRY
TILE
VINYL ACOUSTIC TILE
MODULAR CARPET
ACOUSTIC CEILING TILE
METROPOLITAN
CERAMICS
PROSERIES
MANNINGTON
ARMSTRONG
Model
SCALE: 3/4" = 1'-0"
J
AQ220
VCT
M8206KL
VCT
VCT
A51830
A51830
A51830
Color
108
ACT-PVC
ACT-PVC
ACT
ACT
ACT
PAINT FOR CONCRETE
GYP
A51830
GYPSUM BOARD
LUXURY VINYL TILE
ARMSTRONG
51830
ZODIAQ
QUARTZ COUNTERTOP
DUPONT
ZODIAQ
TW15BW
BASE CABINETS
TECHLINE
FRP
FIBERGLASS REINF.
PANELS
CRANE
W15 BRIGHTON
WALNUT
IVORY 84
Finish
CHESTNUT
BROWN
WHITE
TAN
WHITE
SMOOTH-PRO
KEY LARGO 8206
ULTIMA
PAINT1
PAINT2
Wall Finish
Comments
FRP
Ceiling
Height
8' - 0"
9' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
PAINT1
PAINT1
PAINT1
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
Size
UNGLAZED
6"x6"
PVC
DYED
FINE
TEXTURE
2'x4'
2'x2'
2'x4'
Comments
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
MATCH EXISTING PAINT, LEVEL 3
SHERWIN
WILLIAMS
B58W610, B58V600
WHITE
SEMI-GLOSS
STANDARD GYPSUM BOARD
3
J
Floor Finish
KITCHEN
LOADING DOCK
CONFERENCE
TOILET
STORAGE
ROOM A
ROOM C
ROOM B
COTTAGE
TAN
MOCHA
LATTE
BRIGHT
WALNUT
IVORY
6
2'
1'
0
Name
Ceiling
Finish
FINISH LEGEND - FIRST FLOOR
6
A201
Number
5
ROOM C
12"x12"
NIKA A+E
POLISHED
LAMINATE
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SEE A201 FOR CASEWORK DETAILS
SMOOTH
4'X8'
J
J
FURNITURE AND EQUIPMENT SCHEDULE
NSF
Bolted
Certification in Place
J
Equipment Type
Manufacturer
Model #
Overall Dimensions
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
KITCHEN
3-SINK TABLE
ISLAND TABLE
CORNER L TABLE
PEDESTAL SINK
KITCHEN SINK
GREASE INTERCEPTOR
DISHWASHER
ICEMAKER
SERVICE SINK
2F3-2424-36L
1TG-30108
3TCBX-6096
HSA-10-FA-P
F3L SERIES W/FAUCET MODEL # B-0230
8200 SERIES W/EXTENSION, PCN/FLG # 8250
180CB (CORNER LOCATION)
INDIGO 1106
Z-1996-24
30"Dx112"Wx42"H
30"Dx108"Wx35"H
24"Dx60"Wx96"Lx39"H
19"Dx15"Wx39"H
114"Lx30"Wx42"H
35"Lx20"Wx24"
25"Lx25"Wx72"H
34"Lx30"Wx45"H
24"Dx24"Lx10"H
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
YES
NO
NO
YES
CONFERENCE
CONFERENCE
CONFERENCE TABLE
CONFERENCE CHAIRS
AERO
AERO
AERO
EAGLE
AERO
JAY R SMITH
CMA
MANITOWOC
LIGHT
COMMERCIAL
HON
ALLSTEEL
HUDDLE 30X60 RECTANGULAR (2)
INSPIRE INST-NGONO W/ CASTERS
60"Wx60"L
22"Dx24"Wx36"H
NO
NO
NO
NO
SCALE: 1/2" = 1'-0"
STORAGE
CONFERENCE
4
2
FIRST FLOOR FINISH SCHEDULE - RCP
2
A600
3/32" = 1'-0"
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
4'
Name
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
KITCHEN
BI-DIRECTIONAL DOOR
1
LOADING DOCK
T4
A201
5
T5
102
RO
RO
RO
RO
RO
3' - 0"
3' - 0"
3' - 0"
1B
110
3' - 0"
3' - 0"
0' - 7"
1' - 11"
2' - 6"
T4
ROOM C
101
6' - 8"
RO
6' - 8"
RO
ROOM B
7
UP
102
No.
3' - 7"
5
100
6' - 8"
6' - 8"
RO
SCALE: 3/16" = 1'-0"
8'
4'
0
ROOM A
29
90
RO
6
6' - 8"
101
RO
12'
UP
Description
Date
MAIN LOBBY
16'
10
CONFERENCE
3
A600
STORAGE
4
A600
1/2" = 1'-0"
1/2" = 1'-0"
5
A600
BATHROOM
1/2" = 1'-0"
6
A600
KITCHEN N.
1/2" = 1'-0"
7
A600
KITCHEN W.
1/2" = 1'-0"
SCALE: 1/8" = 1'-0"
A201
6
T5
29
90
T1
T2
T3
100
A201
120
110
8
CONFERENCE
4
2
2' - 6"
STORAGE
2' - 6"
SCALE: 1/16" = 1'-0"
8'
16'
9
NEW DOOR HARDWARE
NEW DOOR HARDWARE
1
A600
Revisions
HARDWARE KEYS:
120
32'
0
4'
8'
UP
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
DOOR SCHEDULE
FIRST FLOOR FINISH SCHEDULE - PLAN
3/32" = 1'-0"
8
A600
NORTH ENTRY DOOR
3/8" = 1'-0"
9
A600
SOUTH ENTRY DOOR
3/8" = 1'-0"
HW 1 :
STORAGE FUNCTION, LEVER, LATCH, MORTICE LOCKSET - SECURE LOCK.
CLOSER, 10" SS KICK PLATE INSIDE. THRESHOLD. HARDWARE WILL BE
INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY
HW 2 :
OFFICE FUNCTION, LEVER , MORTICE LOCKSET. COAT HOOK, CLOSER.
THRESHOLD. SILENCERS. HARDWARE WILL BE INTEGRAL TO
MANUFACTURER SUPPLIED RATED ASSEMBLY
HW 3 :
RESTROOM FUNCTION, LEVER, CLOSER,THUMBTURN INSIDE WITH SAFETY
OVERRIDE FROM OUTSIDE, COAT HOOK, 10" SS KICK PLATE OUTSIDE
HW 4:
STORAGE FUNCTION, LEVER, SURFACE MOUNTED LEVER LOCKSET,
CLOSER, 10" SS KICK PLATE BOTH SIDES. THRESHOLD. HARDWARE WILL
BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY.
HW 5:
EXTERIOR CONTROL ACCESS ENTRANCE FUNCTION. MAG LOCK
INTEGRATED WITH BUILDING SECURITY(INSIDE), EXIST DEVICE (PUSH
BAR), THRESHOLD, DUST SWIPE, GASKET, MORTICE LOCKSET
(EMERGENCY ELECTRONIC OVERRIDE). MATCH EXISTING EXIT DEVICE.
KEY ENTRY FROM OUTSIDE, KEYMARK BY MEDCO.
Drawing Title
FIRST FLOOR FINISH
SCHEDULE
Phase
CONCEPT
A/E Project Number
12-0009.015
Date
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
E
100%
1:1
Number
A600
2'
SCALE: 1-1/2" = 1'-0"
9
E
F
Name
DANCE STUDIO
TEEN ROOM
ROOM F
Floor Finish
M8206KL
Ceiling
Finish
AB6605
AB6605
ACT
Wall Finish
Wall Finish
2
PAINT1
PAINT1
PAINT1
Comments
ADD WALL PAINT AS ALTERNATIVE
ADD WALL PAINT AS ALTERNATIVE
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
SCALE: 1" = 1'-0"
0 1/2'
1'
2'
0
1'
Number
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
DANCE STUDIO
FINISH LEGEND - SECOND FLOOR
9
Key
M8206KL
ACT
3'
TEEN ROOM
ROOM F
SCALE: 3/4" = 1'-0"
1'
2'
AB6605
Manufacturer
MODULAR
CARPET
ACOUSTIC
CEILING TILE
MANNINGTON
ARMSTRONG
Model
KEY LARGO
8206
ULTIMA
Color
Finish
Size
TAN
DYED
2'x2'
WHITE
FINE
TEXTURE
2'x4'
F
Comments
NIKA A+E
MATCH EXISTING PAINT,
LEVEL 3
ARMSTRONG
SUSPENDED
ACOUSTIC
SOUND BAFFLE
6605
WHEAT
FABRIC
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
2'x4'
4'
0
Description
PAINT1
E
SCALE: 1/2" = 1'-0"
2
A601
SECOND FLOOR FINISH SCHEDULE - RCP
HW 1 :
STORAGE FUNCTION, LEVER, LATCH, MORTICE LOCKSET - SECURE LOCK. CLOSER, 10" SS KICK PLATE INSIDE.
THRESHOLD. HARDWARE WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY
3/32" = 1'-0"
HW 2 :
OFFICE FUNCTION, LEVER , MORTICE LOCKSET. COAT HOOK, CLOSER. THRESHOLD. SILENCERS. HARDWARE WILL BE
INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY
HW 3 :
RESTROOM FUNCTION, LEVER, CLOSER,THUMBTURN INSIDE WITH SAFETY OVERRIDE FROM OUTSIDE, COAT HOOK,
10" SS KICK PLATE INSIDE
HW 4:
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
HARDWARE KEYS:
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
architect under the laws of the
State of Maryland, license
number 15975, expiration date
10.16.2015
STORAGE FUNCTION, LEVER, MORTICE LOCKSET, CLOSER, 10" SS KICK PLATE BOTH SIDES. THRESHOLD. HARDWARE
WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY.
HW 5:
EXTERIOR CONTROL ACCESS ENTRANCE FUNCTION. MAG LOCK INTEGRATED WITH BUILDING SECURITY(INSIDE), EXIST
DEVICE (PUSH BAR), THRESHOLD, DUST SWIPE, GASKET, MORTICE LOCKSET (EMERGENCY ELECTRONIC OVERRIDE)
5
12'
A201
SCALE: 3/16" = 1'-0"
DN
No.
Description
Date
DANCE STUDIO
9
UP
Revisions
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
UP
Drawing Title
TEEN ROOM
A201
6
SECOND FLOOR FINISH
SCHEDULE
E
Phase
32'
CONCEPT
A/E Project Number
SCALE: 1/16" = 1'-0"
8'
16'
ROOM F
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
ROOM FINISH SCHEDULE - SECOND FLOOR
12-0009.015
Date
F
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
A601
SECOND FLOOR FINISH SCHEDULE - PLAN
E
W
3/32" = 1'-0"
N
CADD Plot Scale
Revit Model
Drawn By
PG
Checked By
AV
Sheet
1
100%
1:1
Number
A601
POWER SYMBOLS
ABBREVIATIONS
GENERAL NOTES
NON FUSED DISCONNECT SWITCH
PANEL BOARD, NORMAL POWER
JUNCTION BOX, MOUNTING AS INDICATED MOUNTED
J
X
A
AFC
AFF
AMPERES
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
1.
ALL WORK SHOWN IS DIAGRAMMATIC AND IS FOR CIRCUIT ALLOCATION ONLY. THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL EQUIPMENT. COORDINATE ALL DEVICE LOCATIONS
WITH ACTUAL DOOR SWINGS, CABINETS, COUNTERS, ETC., AS INDICATED IN ARCHITECTURAL DRAWINGS.
AFG
AIC
ABOVE FINISHED GRADE
AMPERES INTERRUPTING
CAPACITY
2.
REFER TO ALL CONTRACT DOCUMENTS FOR POSSIBLE INTERFERENCES, BEFORE BID IS MADE. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO
HAVE MADE SUCH EXAMINATIONS OR OF ANY ERROR ON HIS PART.
ATS
AUTOMATIC TRANSFER SWITCH
3.
ALL DISCONNECTS SHALL HAVE A SEPARATE GROUND BAR AND A NEUTRAL BAR.
BC
BFC
BFG
BARE COPPER
BELOW FINISHED CEILING
BELOW FINISHED GRADE
4.
ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING SIGNAGE) OF EQUIPMENT LOCATION, SPARE, OR
SPACE. UPDATE DIRECTORIES FOR ALL ALTERED PANELS. LABEL AND IDENTIFY ALL JUNCTION BOXES WITH PANEL AND CIRCUIT NUMBER.
C
CONDUIT
5.
SEPARATE NEUTRAL CONDUCTORS TO BE RUN WITH ALL BRANCH CIRCUITS.
CAB
CCTV
CKT
CABINET
CLOSED CIRCUIT TELEVISION
CIRCUIT
6.
ALL CIRCUITS TO BE RUN WITH GREEN GROUNDING CONDUCTOR SIZED PER NEC 250.122.
CLG
COTR
CP
7.
MOUNTING HEIGHTS OF ALL DEVICES ARE TO CENTER OF DEVICE, OUTLET, FIXTURE OR EQUIPMENT UNLESS OTHERWISE NOTED.
CT'S
CEILING
CONTRACTING OFFICER
CONTROL PANEL
CURRENT TRANSFORMERS
8.
CONSOLIDATION OF INDIVIDUAL CONDUIT HOME RUNS SHOWN ON THE DRAWINGS SHALL NOT BE PERMITTED WITHOUT PRIOR WRITTEN APPROVAL. LIGHTING AND RECEPTACLE CIRCUITS ONLY MAY BE
EXEMPTED, LIMITED TO NOT MORE THAN THREE CIRCUITS PER CONDUIT HOMERUN.
CTR
CU
COUNTER
COPPER
9.
PROVIDE GROUNDING TYPE EXPANSION FITTINGS OR OTHER APPROVED METHODS TO ALLOW FOR EXPANSION, CONTRACTIONS AND DEFLECTION WHERE CONDUITS CROSS EXPANSION JOINTS.
DEMO
DS
DEMOLITION
DISCONNECT SWITCH
DWG
DRAWING(S)
10.
ALL EMPTY CONDUITS SHALL BE FURNISHED WITH PULL-WIRE AND WILL BE STUBBED-UP A.F.F., OR ABOVE SUSPENDED CEILING AS THE CASE MAY BE, AND SHALL BE CAPPED AT BOTH ENDS.
EF
EM
EXHAUST FAN
EMERGENCY
11.
NUMBER OF BENDS IN A CONDUIT SECTION RUN SHALL NOT EXCEED FOUR 90-DEGREE BENDS, OR EQUIVALENT OF SWEEPS AND RADIUS BENDS.
EMT
EQUIP
EWC
ELECTRICAL METALLIC TUBING
EQUIPMENT
ELECTRIC WATER COOLER
12.
ALL LOW VOLTAGE COMMUNICATIONS WIRING SHALL BE ROUTED IN EMT CONDUITS, OR OTHER APPROVED CONDUITS, EXCEPT WHERE RUN IS CONCEALED IN ACCESSIBLE AREAS. ALL EXPOSED WIRING
SHALL BE PLENUM RATED AND SUPPORTED AS REQUIRED BY CODE.
EWH
ETR
EX
FLA
FLUOR
ELECTRIC WATER HEATER
EXISTING TO REMAIN
EXISTING
FULL LOAD AMPERES
FLUORESCENT
13.
WIRING FOR ALL LOW VOLTAGE COMMUNICATION SYSTEMS SHALL BE RUN IN DEDICATED RACEWAYS AND NOT SHARED WITH POWER WIRING OR OTHER SYSTEMS.
14.
VERIFY MECHANICAL EQUIPMENT SWITCH AND CONNECTION REQUIREMENTS, ITEM BY ITEM WITH THE MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN AND WIRING OF EQUIPMENT. RESOLVE ALL
DISCREPANCIES WITHOUT FURTHER COST TO THE OWNER.
GEC
GROUNDING ELECTRODE
CONDUCTOR
15.
GEN
ENGINE GENERATOR SET
WHERE MOUNTING HEIGHTS ARE NOT DETAILED, INSTALL ELECTRICAL SERVICES AND OVERHEAD EQUIPMENT TO PROVIDE MAXIMUM HEADROOM POSSIBLE. INSTALL ELECTRICAL EQUIPMENT TO FACILITATE
MAINTENANCE, REPAIR AND REPLACEMENT OF EQUIPMENT AND COMPONENTS AS MUCH AS PRACTICAL. CONNECT THE EQUIPMENT FOR EASE OF DISCONNECTING WITH MINIMUM OF INTERFERENCE WITH
OTHER INSTALLATIONS.
GFCI
GROUND FAULT CIRCUIT INTERRUPTER
16.
GFGI
GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACT DOCUMENTS THAT DO NOT CHANGE THE SCOPE OF INSTALLATION OR NATURE OF WORK REQUIRED, THE CONTRACTOR SHALL MAKE
SUCH CHANGES WITHOUT ADDITIONAL COSTS TO COTR. NO OTHER CHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION OF THE COTR.
GFS
GROUND FAULT SENSOR
GND
GROUND
17.
GYP
GYPSUM
HGT
HEIGHT
WHERE THE CONTRACTOR REQUESTS APPROVAL OF AN ITEM OF EQUIPMENT WHICH DEVIATES FROM THE REQUIREMENTS OF THE DRAWINGS AND WILL REQUIRE A REDESIGN OF STRUCTURE,
PARTITIONS, FOUNDATIONS, PIPING, WIRING, OR ANY OTHER PART OF THE MECHANICAL, ELECTRICAL, OR ARCHITECTURAL LAYOUT, ALL SUCH REDESIGN, AND ALL NEW DRAWINGS AND DETAILING
REQUIRED THEREFORE, SHALL BE PREPARED AND PAID FOR BY THIS CONTRACTOR AND SUBMITTED TO THE ARCHITECT FOR APPROVAL.
HID
HPS
HOA
HIGH INTENSITY DISCHARGE
HIGH PRESSURE SODIUM
HAND-OFF-AUTOMATIC
18.
HP
HV
INC
JB
HORSEPOWER
HIGH VOLTAGE
INCANDESCENT
JUNCTION BOX
PROVIDE ALL POWER WIRING FOR POWER, WIRING SHALL INCLUDE FEEDERS, BRANCH CIRCUITS, DISCONNECT SWITCHES, EQUIPMENT TERMINALS. DISCONNECTS SHALL BE PROVIDED IN ACCORDANCE
WITH CODE REQUIREMENTS WHETHER OR NOT SPECIFICALLY INDICATED ON DRAWINGS.
19.
KV
KVA
KVAR
KILO-VOLTS
KILO-VOLTS-AMPERES
KILO-VOLTS-AMPERES REACTIVE
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE ENFORCED EDITION OF THE NATIONAL ELECTRICAL CODE, N.F.P.A. 70, AND ALL LOCAL AND STATE CODES AND
REGULATIONS. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY THE BUILDING AND SAFETY CODES AND ORDINANCES, AND THE RULES AND REGULATIONS
OF ANY LEGAL BODY HAVING JURISDICTION.
20.
ALL ELECTRICAL ITEMS, MATERIALS, DEVICES, APPLIANCES SHALL BE U.L. LABELED.
KW
KWH
LAN
LTG
m
KILO-WATTS.
KILO-WATT-HOURS
LOCAL AREA NETWORK
LIGHTING
METER
21.
ALL NECESSARY ADDITIONS AND ALTERATIONS TO EXISTING WORK SHALL BE INCLUDED IN THE CONTRACT AS REQUIRED TO PROVIDE AND MAINTAIN A COMPLETE AND PROPER ELECTRICAL INSTALLATION.
THIS WORK SHALL INCLUDE:
MM
MAX
MCB
MCC
MILLIMETER
MAXIMUM
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MCP
MFR
MOTOR CIRCUIT PROTECTOR
MANUFACTURER
WORK TO BE DEMOLISHED/REWORKED
EXISTING TO REMAIN
NEW WORK
GFCI
125V, DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER, NEMA 5-20R,
WALL RECESSED MOUNTED 18" AFF, UON. PROVIDE HOT, NEUTRAL, AND GROUND WIRES.
125V, DUPLEX RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 18" AFF, UON. PROVIDE
HOT, NEUTRAL, AND GROUND WIRES.
125V, SIMPLEX RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 18" AFF, UON. PROVIDE
HOT, NEUTRAL, AND GROUND WIRES.
125V, QUADRUPLEX RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 18" AFF, UON.
PROVIDE HOT, NEUTRAL, AND GROUND WIRES.
220V, SPECIAL PURPOSE RECEPTACLE, NEMA 6-20R, WALL RECESSED MOUNTED 18" AFF, UON
125V, DUPLEX FLOOR RECEPTACLE, NEMA 5-20R, FLOOR RECESSED MOUNTED, UON
RECEPTACLE SUFFIXES
XX" AFF
GFCI
= GROUND FAULT CIRCUIT INTERRUPTER
REF
= REFRIGERATOR
FRZ
= FREEZER
R
AC
CTR
W
= MOUNT DEVICE AT INDICATED INCHES AFF TO CENTER
= WASHING MACHINE
DW = DISH WASHER
IM = ICE MACHINE
= RANGE
= AIR CONDITIONER
= 125V, COUNTERTOP RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 6" ABOVE
COUNTER, UON
COMMUNICATION SYMBOLS
DATA OUTLET, WALL RECESSED MOUNT, 18" AFF UON.
TELEPHONE OUTLET, WALL RECESSED MOUNT, 18" AFF UON.
LIGHTING FIXTURE SYMBOLS
WALL MOUNTED LED FIXTURE
SURFACE MOUNTED FLUORESCENT 1'x4'
SURFACE MOUNTED CIRCULAR LIGHT 12"
LED POLE LAMP FIXTURE
LENSED RECESSED FLUORESCENT FIXTURE 2'x4'
CEILING RECESSED MOUNTED 6" LED DOWNLIGHT
RECESSED FLUORESCENT FIXTURE 2'x2'
LED EXIT SIGN AND EMERGENCY LIGHT COMBO
LED EXIT SIGN
OS
CEILING MOUNTED DUAL TECHNOLOGY
OCCUPANCY SENSOR
SUSPENDED CEILING FAN WITH LIGHT
EMERGENCY DUAL HEAD FIXTURE
S
20A, REGULAR VOLTAGE - 120V SINGLE POLE, GRADE SWITCH. WALL MOUNT
AT 48" AFF TO CENTER UON
S
20A, REGULAR VOLTAGE - 120V SINGLE POLE, GRADE SWITCH. WALL MOUNT
AT 48" AFF TO CENTER UON
3
S
120V SINGLE POLE, 1HP MOTOR RATED SWITCH
S
OCCUPANCY SENSOR SWITCH
M
OS
DIRECT/INDIRECT RECESSED FLUORESCENT TROFFER FIXTURE 2'x4'
DIRECT/INDIRECT RECESSED 2'x4' TROFFER LIGHT FIXTURE EQUIPPED WITH
EMERGENCY BATTERY BALLAST
MGB
MH
MAIN GROUND BAR
METAL HALIDE
MIN
MISC
MTR
MINIMUM
MISCELLANEOUS
MOTOR
MTD
MTG
NEC
PNL
PRI
PVC
MOUNTED
MOUNTING
NATIONAL ELECTRICAL CODE
PANEL
PRIORITY
POLYVINYL CHLORIDE
RCP
REFLECTED CEILING PLAN
REC
RGS
TEL
TUNG
TYP
UC
UFC
UH
V
VA
RECEPTACLE
RIGID GALVANIZED STEEL
TELEPHONE
TUNGSTEN
TYPICAL
UNDERGROUND COMMUNICATION
UNIFIED FACILITIES CRITERIA
UNIT HEATER
UNLESS OTHERWISE NOTED
UNDERGROUND POWER
UNINTERRUPTIBLE POWER SUPPLY
UNDERGROUND SECURITY
VOLTS
VOLT-AMPERES
VFC
W
WHE
VARIABLE FREQUENCY CONTROLLER
WATTS
WAREHOUSE
WP
XFMR
WEATHER PROOF
TRANSFORMER
UON
UP
UPS
US
22.
a.
RELOCATION OF PULL BOXES, RACEWAYS, ETC., TO PERMIT THE INSTALLATION OF NEW EQUIPMENT.
b.
DISCONNECTION/RECONNECTIONS/REMOVAL/REINSTALLATION OF ELECTRICAL SUPPLY, CONTROL, AND UTILIZATION EQUIPMENT REQUIRED FOR CONTINUED OPERATION, INCLUDING TEMPORARY
WORK AS REQUIRED.
c.
PROVISIONS FOR THE RELOCATION OF ALL PIPING, DUCTWORK, ETC., AS REQUIRED FOR ELECTRICAL WORK, WHERE NOT SHOWN OR SPECIFIED BY OTHERS. THE ELECTRICAL CONTRACTOR SHALL
NOTIFY THE A/E TEAM PRIOR TO BID SO THAT THE APPROPRIATE TRADE MAY BE ASSIGNED TO BID; OTHERWISE, THE ELECTRICAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL SUCH
RELOCATIONS.
d.
EQUIPMENT TO BE TURNED OVER TO OWNER, SHALL BE TURNED OVER IN CLEAN AND WORKING CONDITION.
e.
DISCONNECT ELECTRICAL SERVICES TO EQUIPMENT TO BE REMOVED. REMOVE ALL UNUSED CONDUIT AND CONDUCTORS BACK TO POINT OF SERVICE, OR NEXT ACTIVE DEVICE, UNLESS THEY ARE
TO BE REUSED UNDER NEW CONSTRUCTION.
f.
UNUSED CONDUITS CAN BE ABANDONED WHERE CONCEALED IN FLOORS OR WALLS, BUT MUST BE REMOVED FROM CEILING SPACES, EXPOSED AREAS AND ACCESSIBLE LOCATIONS.
g.
WHERE WORK UNDER THIS CONTRACT REQUIRES EXTENSION, RELOCATION, RECONNECTIONS OR MODIFICATIONS TO EXISTING EQUIPMENT OR SYSTEMS, THE EXISTING EQUIPMENT OR SYSTEM
SHALL BE RESTORED TO ITS ORIGINAL AND OPERATING CONDITION. EXTEND NEW HOMERUNS OR CIRCUIT EXTENSIONS, WHERE REQUIRED. DISCONNECT AND REMOVE ALL EQUIPMENT INDICATED
TO BE DEMOLISHED, INCLUDING OUTLETS, DEVICES, RELAYS, AND CONDUCTORS.
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
MAINTAIN ELECTRICAL WORKING SPACE CLEARANCE PER NEC 110.26
No.
Description
Date
HOMERUN SPECIFICATION
PHASE CONDUCTORS
HOME RUN TO PANEL-ARROWHEADS INDICATE
CIRCUITS. WIRE INDICATED ARE NEUTRAL AND
THREE HOT LEGS (A DIFFERENT PHASE FOR
EACH CIRCUIT) MAXIMUM THREE CIRCUITS PER
CONDUIT. ALL CIRCUITRY SHALL ALSO CONTAIN
AN INSULATED GROUNDING CONDUCTOR
(GROUND TICK MARK). WHEN A SINGLE GROUND,
NEUTRAL AND PHASE CONDUCTOR (SINGLE
PHASE L-N CIRCUITS) ARE INSTALLED. MINIMUM CONDUCTORS
SHALL BE #12 AWG IN
3/4"C UON
DISCONNECT SWITCHES SUFFIXES AND SPECIFICATION
Revisions
Drawing Title
ELECTRICAL NOTES AND
SYMBOLS
Phase
CONCEPT
35%
60%
90%
100%
NEUTRAL
A/E Project Number
VFD
=
VARIABLE FREQUENCY DRIVER
WP
NEMA XX
=
=
WEATHER PROOF NEMA 3R, NEMA 4, OR NEMA 12
SPECIFIC NEMA CONFIGURATION
XXXAF
XXXAT
=
FRAME SIZE
TRIP SIZE
12-0009.015
GROUNDING
Date
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
1:1
Number
E001
#
SCALE: 1-1/2" = 1'-0"
2. NEW 120V, 1ø LED FLOOD LIGHT.
CONNECT TO NEAREST AVAILABLE SINGLE
POLE CIRCUIT ON PANEL OL. FIXTURE TO
BE MOUNTED 20'-0" A.F.F. COORDINATE
INSTALLATION OF FIXTURE CENTERED ON
BARN ABOVE EXTERIOR BUILDING
MOULDINGS. COORDINATE WITH OWNER
PRIOR TO INSTALLATION. CONTRACTOR
SHALL ID NEAREST AVAILABLE CIRCUIT.
4. NEW PHOTOCELL TIED TO NEW EXTERIOR
FIXTURES AND TIE TO NEW TIMECLOCK.
5. NEW 365/7 DAY ELECTRONIC
PROGRAMMABLE TIMECLOCK.
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
0
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
SCALE: 1" = 1'-0"
1'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
2'
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
3. NEW 120V, 1ø LED WALLPACK LIGHT
FIXTURES. REUSE EXISTING WIRING AND
CONNECT TO EXISTING CIRCUIT.
2'
0
1'
1. NEW 120V, 1ø LED POLE LIGHT FIXTURE
MOUNTED 15' A.F.F. CONNECT TO NEAREST
AVAILABLE SINGLE POLE CIRCUIT ON
PANEL OL. CONTRACTOR SHALL ID
NEAREST AVAILABLE CIRCUIT.
3
3
H
SCALE: 1/2" = 1'-0"
UP
UP
SCALE: 1/4" = 1'-0"
0
UP
4
4
5
G
1
TC
12'
F
SCALE: 3/16" = 1'-0"
8'
4'
PC
PC
2
No.
Description
Date
16'
0
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
18' - 5 1/2"
2'
4'
8'
0
1'
2'
4'
H
SCALE: 1/8" = 1'-0"
0
4'
8'
PROPERTY LINE
Revisions
1
E101
SITE PLAN - ELECTRICAL
Drawing Title
SCOPE OF WORK
ELECTRICAL SITE PLAN
1/16" = 1'-0"
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
KEY NOTES
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
1:1
Drawn By
Author
Checked By
Checker
Sheet
E
100%
Number
E101
SCALE: 1-1/2" = 1'-0"
1'
2'
2
EDL101
2
EP101
2'
0
2
EL101
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
SCALE: 1" = 1'-0"
KITCHEN
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 1/2" = 1'-0"
MAIN LOBBY
0
8'
0
1'
2'
4'
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
1
2'
0 1/2'
1'
2
EDP101
SCALE: 1/4" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
SCALE: 3/16" = 1'-0"
No.
STORAGE
4
2
1
EDL101
OFFICE
1
EP101
1
EDP101
Revisions
Drawing Title
SCOPE OF WORK
ELECTRICAL FIRST FLOOR
OVERALL PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
1
EL101
CONFERENCE
SCALE: 1/8" = 1'-0"
8'
4'
0
Description
OFFICE
16'
0
4'
8'
12'
0
2'
4'
10
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
1
E102
ELECTRICAL FIRST FLOOR OVERALL PLAN
3/16" = 1'-0"
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
E
100%
1:1
Number
E102
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
SCALE: 1" = 1'-0"
1'
3'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
DN
DANCE STUDIO
TEEN ROOM
9
E
SCALE: 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
SCALE: 3/16" = 1'-0"
No.
F
1
EDL102
Revisions
Drawing Title
SCOPE OF WORK
ELECTRICAL SECOND FLOOR
OVERALL PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
ROOM F
SCALE: 1/8" = 1'-0"
8'
4'
0
Description
1
EL102
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
1'
2'
0 1/2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
1
E103
ELECTRICAL SECOND FLOOR OVERALL PLAN
S
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
1:1
3/16" = 1'-0"
Sheet
E
W
N
Number
E103
SCALE: 1-1/2" = 1'-0"
2'
1'
0
LOAD
"a"
LOCAL ON/OFF SWITCH(S)
LOCATE AS INDICATED ON
DRAWINGS
RED
NEUTRAL
PHASE
S
3a
S
3a
2'
120V OR 277V,
SINGLE PHASE
OCCUPANCY
1'
SCALE: 1" = 1'-0"
NTS
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
24"
4'
0
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
E501
LINE VOLTAGE CEILING MOUNTED OCCUPANCY SENSOR WIRING DIAGRAM WITH THREE WAY
SWITCHES.
2'
0 1/2'
1
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
SENSOR
SCALE: 1/2" = 1'-0"
12"
BASE PLATE AND BOLTS
PER LIGHT POLE
MANUFACTURER
LUMINAIRE POST AND BASE AS PER LIGHTING VENDOR.
REFER TO DETAIL #1 ON THIS SHEET.
SLOPE TOP AWAY FROM
POLE
24"x24" CONC. PIER
FOR LIGHT POLE
8'
0
1'
2'
EQ.
5' MIN.
SCALE: 1/4" = 1'-0"
6 - #6 VERT
12'
0
2'
4'
#3 TIE @12" MAX
SCALE: 3/16" = 1'-0"
2
E501
LUMINAIRE POST BASE DETAIL
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
No.
Description
Date
1 : 20
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
24"x24"
Revisions
Drawing Title
ELECTRICAL DETAILS
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
NEUTRAL
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
1:1
Number
E501
1. REMOVE ALL EXISTING WIRING WITHIN WORK AREA BACK TO
SOURCE. FEEDERS SERVING PANEL K AND A ARE TO BE REUSED.
DEMOLITION KEY NOTES
2. EXISTING 2'x4' LIGHT FIXTURE IS TO BE DEMOLISHED.
3. EXISTING 2'x2' LIGHT FIXTURE IS TO BE DEMOLISHED.
1
1
5. EXISTING CIELING FAN IS TO BE REMOVED.
6. EXISTING 1'x4' SURFACE MOUNTED LIGHT FIXTURE IS TO BE
REMOVED.
7. EXISTING EMERGENCY WALL PACK LIGHT FIXTURE IS TO BE
REMOVED.
2'
SD
1
8. EXISTING LIGHT FIXTURES IN THE LOADING DOCK ARE TO BE
REMOVED. RETAIN WIRING FOR REUSE.
SCALE: 1" = 1'-0"
2
1'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
4. EXISTING ROUND SURFACE MOUNTED LIGHT FIXTURE IS TO BE
REMOVED.
3
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
1
SD
3'
0 1/2'
#
1. EXISTING LIGHT SWITCH IS TO BE DEMOLISHED.
4
SCALE: 1-1/2" = 1'-0"
0
1'
1
NIKA A+E
5
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
2'
1'
0
4'
1
APARTMENT AND BATHROOM ELECTRICAL REFLECETED CEILING PLAN - ENLARGED DEMOLITION
SCALE: 1/2" = 1'-0"
3/8" = 1'-0"
SCALE: 1/4" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
1
12'
0
2'
4'
8'
0
1'
2'
EDL101
LOADING DOCK
SCALE: 3/16" = 1'-0"
1B
No.
6
KITCHEN
1
SCALE: 1/8" = 1'-0"
8'
4'
6
6
6
Revisions
6
6
Drawing Title
SCOPE OF WORK
ELECTRICAL FIRST FLOOR
ENLARGED REFLECTED
CEILING PLAN - DEMOLITION
7
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
6
6
0
Description
8
16'
0
4'
8'
1
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL SHEET NOTES
S
2
EDL101
ELECTRICAL FIRST FLOOR ENLARGED REFLECETED CEILING PLAN - DEMOLITION
3/8" = 1'-0"
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
Drawn By
JO
Checked By
AM
Sheet
E
W
N
CADD Plot Scale
Revit Model
1:1
Number
EDL101
1. RETAIN ALL EXISTING WIRING FOR REUSE.
#
SCALE: 1-1/2" = 1'-0"
1. EXISTING 2'x4' TROFFER LIGHT FIXTURE IS TO BE REMOVED.
2. EXISTING LIGHT SWITCH IS TO BE REMOVED.
3. EXISTING EXIT SIGN LIGHT FIXTURE IS TO BE REMOVED.
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
4. EXISTING EMERGENCY WALL PACK LIGHT FIXTURE IS TO BE REMOVED.
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
SCALE: 1" = 1'-0"
0 1/2'
1'
2'
0
1'
DEMOLITION KEY NOTES
3'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
4
3
ROOM F
F
1
1
1
1
1
1
4'
0
1'
NIKA A+E
2'
2
2
1
1
1
SCALE: 1/2" = 1'-0"
1
1
2
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
1
1
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
ELECTRICAL SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - COMPUTER ROOM F DEMOLITION
3/8" = 1'-0"
SCALE: 3/16" = 1'-0"
No.
Description
Date
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
EDL102
Revisions
Drawing Title
SCOPE OF WORK
ELECTRICAL SECOND FLOOR
ENLARGED RCP - COMPUTER
ROOM F - DEMOLITION
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL SHEET NOTES
S
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
Drawn By
JO
Checked By
AM
Sheet
E
W
N
CADD Plot Scale
Revit Model
1:1
Number
EDL102
1. EXISTING BRANCH WIRING FROM THE APARTMENT SHALL BE REMOVED
BACK TO PANEL A.
2. RETAIN FEEDERS FOR PANELS A AND K.
GFCI
R
J
1
SCALE: 1-1/2" = 1'-0"
0
DEMOLITION KEY NOTES
1
1
W
TOILET
1
2. EXISTING TELEPHONE AND DATA OUTLETS ARE TO BE REMOVED.
PANEL OL
(ETR)
EF
5. EXISTING EXHAUST FAN IS TO BE REMOVED.
6. EXISTING SWITCH FOR EXHAUST FAN IS TO BE REMOVED.
3
PANEL B
(ETR)
2'
1
7. EXISTING 120/208V, 3ø, 400A PANELBOARD K IS TO BE REMOVED.
8. EXISTING ICE MACHINE IS TO BE REMOVED.
9. EXISTING DISH WASHER IS TO BE REMOVED.
SCALE: 1" = 1'-0"
APARTMENT
1'
4. EXISTING HOOD IS TO BE REMOVED.
A
1
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
10. EXISTING JUNCTION BOX IS TO BE REMOVED. CONTRACTOR SHALL
CONTACT OWNER PRIOR TO REMOVAL.
2
1
11. EXISTING WALL MOUNTED AC UNITS ARE TO BE REMOVED.
12. EXISTING RANGE, REFRIGERATOR, AND FREEZER RECEPTACLE ARE TO
REMAIN.
1
1
3'
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
3. EXISTING 120/208V, 3ø, 100A PANELBOARD A IS TO BE REMOVED.
6
J
2
#
1. EXISTING RECEPTACLES ARE TO BE REMOVED.
3
5
REF
1'
4
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1
SCALE: 3/4" = 1'-0"
1
AC
1
1
11
11
AC
J
J
4'
0
1'
2'
1
SCALE: 1/2" = 1'-0"
EDP101
APARTMENT AND BATHROOM ELECTRICAL PLAN - ENLARGED - DEMOLITION
3/8" = 1'-0"
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
1
12
12
REF
12
FRZ
J
12'
4
SCALE: 3/16" = 1'-0"
8'
4'
0
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
7
R
No.
LOADING DOCK
Description
Date
1B
9
8
J
16'
J
KITCHEN
1
SCALE: 1/8" = 1'-0"
0
4'
8'
J
Revisions
10
Drawing Title
SCOPE OF WORK
1
ELECTRICAL FIRST FLOOR
ENLARGED PLANS DEMOLITION
10
1
Phase
CONCEPT
32'
A/E Project Number
SCALE: 1/16" = 1'-0"
16'
Date
8'
35%
60%
90%
100%
J
12-0009.015
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL SHEET NOTES
S
2
EDP101
KITCHEN ELECTRICAL PLAN - ENLARGED - DEMOLITION
3/8" = 1'-0"
Drawing Scale: AS NOTED
CADD Filename
07-15-15
Drawn By
JO
Checked By
AM
Sheet
E
W
N
CADD Plot Scale
Revit Model
1:1
Number
EDP101
#
1. NEW 3 WAY LIGHT SWITCHES. TIE TO OCCUPANCY SENSOR.
2. NEW 2'x4' DIRECT/INDIRRECT TROFFER LIGHT FIXTURE.
3. NEW LENSED 2'x4' LIGHT FIXTURE.
A-11
9
7
4. NEW SINGLE POLE LIGHT SWITCH. TIE TO OCCUPANCY SENSOR.
5. NEW EMERGENCY WALL PACK/SIGN COMBO LIGHT FIXTURE.
E
SCALE: 1-1/2" = 1'-0"
0
1'
D
8
6. NEW CEILING MOUNTED OCCUPANCY SENSOR.
7. NEW CEILING MOUNTED LED EXIT SIGN.
4
2
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
8. NEW 2'X2' DIRECT/INDIRECT LIGHT FIXTURE.
D
9. NEW LIGHT SWITCH WITH DIMMER.
10
A
10. NEW SINGLE POLE LIGHT SWITCH WITH OCCUPANCY SENSOR.
OS
2'
11. TIE TO EXISTING LOADING DOCK LIGHT CIRCUIT.
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
2
SCALE: 1" = 1'-0"
2
A
OS
2
A
2
6
6
OS
3'
0 1/2'
1'
A-9
NIKA A+E
2
SCALE: 3/4" = 1'-0"
2'
1'
A
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
A
4
CONFERENCE
2
4'
0
2
STORAGE
1
APARTMENT ELECTRICAL REFLECTED CEILING PLAN - ENLARGED - PROPOSED
SCALE: 1/2" = 1'-0"
3/8" = 1'-0"
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
EL101
11
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
11
3
12'
3
LOADING DOCK
3
B
16'
KITCHEN
3
B
OS
SCALE: 1/8" = 1'-0"
8'
4'
11
11
3
B
3
3
3
B
3
B
Revisions
Drawing Title
SCOPE OF WORK
ELECTRICAL FIRST FLOOR
ENLARGED REFLECTED
CEILING PLAN
Phase
B
5
CONCEPT
C
A/E Project Number
3
SCALE: 1/16" = 1'-0"
8'
16'
12-0009.015
Date
1
S
2
EL101
KITCHEN ELECTRICAL REFLECTED CEILING PLAN - ENLARGED - PROPOSED
3/8" = 1'-0"
Date
7
K-14
32'
Description
6
1
B
No.
1B
3
3
B
0
B
1
SCALE: 3/16" = 1'-0"
0
4'
8'
B
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
NEW WORK KEY NOTES
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
E
100%
1:1
Number
EL101
1. RETAIN ALL EXISTING WIRING FOR REUSE.
NEW WORK KEY NOTES
#
SCALE: 1-1/2" = 1'-0"
0
1'
1. NEW SINGLE POLE LIGHT SWITCH. TIE TO OCCUPANCY SENSOR.
2. NEW 2'x4' TROFFER LIGHT FIXTURE.
3. NEW 2'x4' TROFFER LIGHT FIXTURE WITH EMERGENCY BATTERY.
4. NEW EXIT SIGN LIGHT FIXTURE WITH EMERGENCY BATTERY.
5. REUSE EXISTING WIRING FOR CIRCUIT. WIRING SHOWN MAY NOT REFLECT
ACTUAL WIRE CONFIGURATION.
6. NEW CEILING MOUNTED OCCUPANCY SENSOR.
7. NEW SINGLE POLE LIGHT SWITCH SERVING LIGHT IN THE
TELECOMMUNICATIONS ROOM.
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1
SCALE: 3/4" = 1'-0"
0
1'
3'
SCALE: 1" = 1'-0"
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
2'
0 1/2'
1'
2'
8. NEW SINGLE POLE LIGHT SWITCH SERVING LIGHT IN THE STORAGE ROOM.
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
NIKA A+E
E
ROOM F
4
2
F
4'
5
6
6
3
2
A
2
OS
A
A
A
SCALE: 1/2" = 1'-0"
0
1'
2'
OS
8
6
A
A
A
2
2
A
2
A
OS
3
A
SCALE: 1/4" = 1'-0"
TELECOMMUNICATIONS
ROOM
7
STORAGE ROOM
2
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
12'
0
2'
4'
8'
2
3/8" = 1'-0"
SCALE: 3/16" = 1'-0"
EL102
ELECTRICAL SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - COMPUTER ROOM F
No.
Description
Date
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
1
Revisions
Drawing Title
SCOPE OF WORK
ELECTRICAL SECOND FLOOR
ENLARGED RCP - COMPUTER
ROOM F
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL SHEET NOTES
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
E
100%
1:1
Number
EL102
SCALE: 1-1/2" = 1'-0"
2'
1'
0
SCALE: 1" = 1'-0"
1'
2'
LUMINARIES SCHEDULE
LAMP DATA
3'
0 1/2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
FIXTURE TYPE
MOUNTING
MOUNTING
HEIGHT
(A.F.F.)
VOLTS
NOMINAL
WATTS
TOTAL
WATTS
LAMPS
BULB
TYPE
TYPE
MANUFACTURER
CATALOG NO.
NOTES
SCALE: 3/4" = 1'-0"
A
2'x4' RECESSED TROFFER
DIRECT/INDIRECT
CEILING
RECESSED
8'-0"
120
28
56
2
T5
FLUOR
PHILIPS LIGHTING
B
2' x 4' LENSED ENCLOSED
CEILING
RECESSED
8'-0"
120
28
56
2
T5
FLUOR
PHILIPS LIGHTING
2SPG228-FS01-120
C
WALL MOUNTED COMBO EMERGENCY
LIGHT
7'-6"
120
2.8
2.8
2
LED
LED
PHILIPS LIGHTING
VCLANGW
D
2'x2' RECESSED TROFFER
DIRECT/INDIRECT
8'-0"
120
14
28
2
T5
FLUOR
PHILIPS LIGHTING
2SPG214R-FS-120
E
CEILING EXIT LIGHT
8'-0"
120
4
4
1
LED
LED
PHILIPS LIGHTING
VEGWEM
F
WALL MOUNTED FLOOD LIGHT
20'-0"
120
52
52
32
LED
LED
PHILIPS LIGHTING
CSFS16L530NWG1SFSP120
G
LED POLE LIGHT
FREE STANDING
15'
120
77
77
1
LED
LED
PHILIPS LIGHTING
ECF-1-5-75LA-4853-CW-UNV-BLP-PCB
H
WALLPACK FIXTURE
WALL MOUNT
EXISTING
120
13.9
13.9
1
LED
LED
PHILIPS LIGHTING
TLW-10LED-4K-PCB-1
2AVG228-PMW-120
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
FOR EMERGENCY FIXTURES, PROVIDE 90 MINUTE BATTERY BACKUP
WITH EMERGENCY BALLAST.
SCALE: 1/2" = 1'-0"
WALL MOUNT
CEILING
RECESSED
CEILING MOUNT
SCALE: 1/4" = 1'-0"
WALL MOUNT
SCALE: 3/16" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
No.
Description
Date
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
1'
2'
TYPE
Revisions
Drawing Title
ELECTRICAL LUMINARE
SCHEDULE
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
1:1
Number
EL501
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
SCALE: 1" = 1'-0"
1'
SCALE: 1/2" = 1'-0"
2.8
1.4
1.6
1.8
2.1
2.1
2.3
2.5
2.5
2.5
2.7
1.3
1.5
1.6
1.7
1.9
2.1
2.2
2.2
2.2
2.2
1.4
1.3
1.1
1.0
0.7
1.9
1.6
1.4
1.2
1.2
0.8
0.3
0.1
0.0
0.0
3.3
1.9
1.3
1.5
1.5
1.6
1.8
2.0
2.2
2.0
2.1
2.2
1.9
1.6
1.4
1.3
1.2
0.9
0.3
0.1
0.0
0.0
3.7
4.1
4.7
2.3
1.3
1.4
1.5
1.6
1.7
1.9
2.0
1.7
1.9
2.0
1.8
1.6
1.4
1.3
1.3
0.9
0.3
0.1
0.0
0.0
4.1
4.6
5.1
2.0
1.3
1.4
1.5
1.5
1.6
1.7
1.6
1.7
1.6
1.7
1.7
1.5
1.4
1.3
1.3
0.8
0.3
0.1
0.0
0.0
3.6
4.0
4.6
2.3
1.2
1.4
1.4
1.5
1.6
1.8
2.0
1.6
1.8
1.9
1.7
1.5
1.4
1.3
1.2
0.9
0.3
0.1
0.0
0.0
2.5
3.0
3.4
1.9
1.2
1.3
1.3
1.4
1.5
1.7
1.8
1.6
1.7
1.8
1.6
1.4
1.3
1.2
1.2
0.8
0.3
0.1
0.0
0.0
0
SCALE: 1/4" = 1'-0"
SCALE: 3/16" = 1'-0"
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
SCALE: 3/4" = 1'-0"
3'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1'
2'
0 1/2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
0.0
0.0
0.0
0.0
0.0
0.0
1.4
1.8
2.1
1.4
1.0
1.2
1.2
1.3
1.5
1.5
1.6
1.5
1.5
1.5
1.5
1.4
1.3
1.2
1.1
0.8
0.3
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.8
1.0
1.2
0.9
0.9
1.1
1.1
1.3
1.3
1.4
1.4
1.4
1.4
1.4
1.3
1.3
1.2
1.1
1.0
0.6
0.3
0.1
0.0
0.0
0.0
0.0
0.1
0.2
0.3
0.3
0.4
0.5
0.7
0.7
0.7
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.3
1.2
1.2
1.1
1.0
1.0
0.8
0.5
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.2
0.2
0.3
0.4
0.4
0.6
0.8
0.9
1.0
1.1
1.1
1.2
1.2
1.2
1.1
1.1
1.0
0.9
0.9
0.7
0.4
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.1
0.2
0.2
0.3
0.4
0.5
0.7
0.8
0.9
0.9
1.0
1.0
1.0
1.0
0.9
0.9
0.7
0.6
0.4
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.1
0.1
0.2
0.3
0.4
0.4
0.5
0.5
0.5
0.4
0.5
0.5
0.5
0.4
0.4
0.3
0.2
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
No.
Description
Drawing Title
SCOPE OF WORK
1
EL601
ELECTRICAL LIGHTING
CALCULATIONS - SITE
ELECTRICAL LIGHTING CALCULATIONS - SITE
1" = 10'-0"
Phase
32'
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
Revisions
CONCEPT
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
E
100%
1:1
Number
EL601
7
W
A-2
SCALE: 1-1/2" = 1'-0"
+48"
+48"
A.F.F.
1
NEW 208V, 1ø, 1.5kW ELECTRIC HEATER CUH-1.
CUH-1.
3. NEW
11
A-8,10
A-2
NEW 208V, 1ø, .75kW ELECTRIC HEATER CUH-2.
CUH-2.
2. NEW
A-24
A-24
A.
4. NEW 120/208V, 3ø, 150
150 MAINS
MAINS 70A
70A MCB
MCB LOAD
LOAD CENTER PANELBOARD
PANELBOARD A.
A-7
A-7
CUH-1
5. NEW 240V, 1ø, 30A
30A DISCONNECT
DISCONNECT SWITCH FOR ELECTRIC HEATER
HEATER CUH-1
ABOVE
ABOVE CEILING.
CEILING.
88
A-3 A-3
FRZ
6. NEW TELEPHONE AND DATA DUAL
DUAL OUTLET.
OUTLET.
STORAGE
A-1
A-1
4
11
11
44
PANEL OL
OL
PANEL
A-8,10
7
W
11
11
JJ
15
15
M J
11
22
M
J
A-21,23
A-21,23
A-16,18
A-16,18
9. NEW 220V RECEPTACLE FOR ICE MACHINE.
MACHINE.
11
M
J
16
16
A-4
A-4
33
A-17,19
A-17,19
A-17,19
A-17,19
SCALE: 1" = 1'-0"
1'
1'
12. NEW 120/208V, 3ø, 350A MCB PANELBOARD
PANELBOARD K.
K.
J
26
26
55
M
HOOD
13. NEW 1/2HP, 208V, 3ø,
3ø, 60Hz,
60Hz, EXHAUST
EXHAUST FAN EF-1. OPERATION VIA HOOD
CONTROLS. EXHAUST
EXHAUST FAN
FANIS
IS TO
TO BE
BE LOCATED
LOCATED ON
ON ROOF.
ROOF. PROVIDE
PROVIDE INTERLOCK
INTERLOCK
CONTROLS.
PER MECHANICAL
MECHANICAL SHEET
SHEET M601.
M601.
PER
CUH-2
14. NEW 240V, 1ø, 30A
30A DISCONNECT
DISCONNECT SWITCH FOR ELECTRIC HEATER CUH-2
ABOVE CEILING.
CEILING. PROVIDE
PROVIDE INTERLOCK
INTERLOCK PER
PER MECHANICAL
MECHANICAL SHEET
SHEET M601.
M601.
ABOVE
A-20,22
A-20,22
CONFERENCE
CONFERENCE
A-12,14
A-12,14
UNIT FCU-2.
FCU-2.
16. NEW 0.23FLA, 208V, 1ø,
1ø, 60Hz
60Hz SPLIT
SPLIT SYSTEM
SYSTEM HVAC UNIT
66
A-17,19
A-17,19
J
22
J
17. NEW 0.23FLA, 208V, 1ø,
1ø, 60Hz
60Hz SPLIT
SPLIT SYSTEM
SYSTEM HVAC UNIT
UNIT FCU-4.
FCU-4.
18
18
14
14
18. NEW 0.23FLA, 208V, 1ø,
1ø, 60Hz
60Hz SPLIT
SPLIT SYSTEM
SYSTEM HVAC UNIT
UNIT FCU-5.
FCU-5.
3'
3'
A-5
A-5
M
J M
11
CTR
A-13
A-13
38
38
SCALE: 3/4" = 1'-0"
2'
2'
1'
1'
1
11
J
19. NOT USED.
USED.
26
26
A-25,27
A-25,27
20. NEW 30MCA, 208V, 1ø,
1ø, 60Hz
60Hz OUTDOOR
OUTDOOR CONDENSING UNIT
UNIT CU-1.
CU-1.
NIKA A+E
21. NEW 20KW, 208V, 3ø,
3ø, 60Hz
60Hz ELECTRIC DUCT HEATER
HEATER EDH-1.
EDH-1.
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
22. NEW 1.5HP, 208V, 3ø, 60Hz SUPPLY FAN SF-1. PROVIDE INTERLOCK
INTERLOCK PER
PER
MECHANICAL
MECHANICAL SHEET
SHEETM601.
M601.
J
14
14
66
36
36
1
22
11
J
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
UNIT FCU-1.
FCU-1.
15. NEW 0.28FLA, 208V, 1ø,
1ø, 60Hz
60Hz SPLIT
SPLIT SYSTEM
SYSTEM HVAC UNIT
22
37
37
11
0
0
10. NEW 220V RECEPTACLE FOR DISH WASHER.
WASHER.
11. CONNECT
CONNECT FIRE
FIRE SUPPRESSION SYSTEM
SYSTEM TO
TO FIRE
FIRE ALARM PANEL.
PANEL.
17
17
26
26
26
26
14
14
0
0 1/2'
PANEL
PANEL B
B
A-17,19
J
26
26
2'
2'
A-6
A-6
PANEL
PANEL A
32
32
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
7. NEW
NEW 220V RECEPTACLE
RECEPTACLE FOR
FOR DRYER.
DRYER.
8. NEW SIMPLEX RECEPTACLE FOR REFRIGERATOR
REFRIGERATOR AND
AND FREEZER.
FREEZER. MTD
MTD 60"
60"
A.F.F.
A.F.F.
CTR
1'
1'
REF
0
0
1
GFCI
GFCI
88
##
DUPLEX RECEPTACLES.
RECEPTACLES.
1. NEW 125V WALL MOUNTED
MOUNTED DUPLEX
11
CTR
23. NEW 1/6HP, 208V, 1ø,
1ø, 60Hz,
60Hz, EXHAUST
EXHAUST FAN EF-2. OPERATION VIA
DISHWASHER
DISHWASHER CONTROLS.
CONTROLS. PROVIDE
PROVIDE INTERLOCK PER MECHANICAL
MECHANICAL SHEET
M601.
WP
WP
WP
K-24,26
K-24,26
EXHAUST FAN
FAN EF-1
EF-1 TO
TO BE
BE PROVIDED
PROVIDED WITH
24. NEW MOTOR SWITCH FOR EXHAUST
EQUIPMENT.
EQUIPMENT.
35
35
K-27,29
K-27,29
31
31
USED.
25. NOT USED.
26. NEW MOTOR RATED SWITCH FOR THE
THE FAN
FAN COIL
COIL UNITS.
UNITS.
20
20
27. NEW MOTOR RATED SWITCH FOR DISHWASHER
DISHWASHER EXHAUST
EXHAUST FAN
FAN EF-2.
EF-2.
34
34
4'
4'
28. NEW 240V, 3ø, 100A
100A NON-FUSED
NON-FUSED DISCONNECT SWITCH
SWITCH FOR
FOR ELECTRIC
ELECTRIC
DUCT
DUCT HEATER
HEATER EDH-1.
EDH-1.
SCALE: 1/2" = 1'-0"
1
EP101
EP101
APATRMENT
APATRMENT ELECTRICAL
ELECTRICAL PLAN
PLAN -- PROPOSED
PROPOSED
30. NEW MOTORIZED DAMPER
DAMPER
3/8" == 1'-0"
1'-0"
3/8"
31. NEW 240V, 3ø, 60A FRAME, 40A FUSED DISCONNECT SWITCH
SWITCH FOR
FOR
CONDENSING
CONDENSING UNIT
UNIT CU-1.
CU-1.
32. NEW 0.23FLA, 208V, 1ø,
1ø, 60Hz
60Hz SPLIT
SPLIT SYSTEM
SYSTEM HVAC UNIT
UNIT FCU-3.
FCU-3.
33. CONNECT
CONNECT EXISTING
EXISTING RANGE,
RANGE, REFRIGERATOR,
REFRIGERATOR, AND
AND FREEZER
FREEZER RECEPTACLES
RECEPTACLES
TO
TO NEW
NEW PANELBOARD
PANELBOARD K.
K.
UNIT CU-2.
CU-2.
34. NEW 29MCA, 208V, 1ø,
1ø, 60Hz
60Hz OUTDOOR
OUTDOOR CONDENSING UNIT
SWITCH FOR
FOR
35. NEW 240V, 3ø, 60A FRAME, 40A FUSED DISCONNECT SWITCH
CONDENSING
CONDENSING UNIT
UNIT CU-2.
CU-2.
8'
8'
0
0
1'
1'
2'
2'
29. NEW MOTOR RATED
RATED SWITCH
SWITCH FOR
FOR SUPPLY
SUPPLY FAN
FAN SF-1.
SF-1.
23
23
PROVIDE
36. NEW 120V, 1ø, 60Hz, 0.7kW OPEN COIL DUCT HEATER.
HEATER. PROVIDE
INTERLOCK
INTERLOCK PER
PER MECHANICAL
MECHANICAL SHEET
SHEET M601.
M601.
JJ
SCALE: 1/4" = 1'-0"
0
0
2'
2'
4'
4'
K-11,13
K-11,13
12
12
27
27
38. NEW JUNCTION BOX WITH 3/4" CONDUIT TO PANEL
PANEL "A"
"A" ABOVE
ABOVE CEILING
CEILING
FOR FUTURE
FUTURE TV
TV PROJECTOR.
PROJECTOR. PROVIDE
PROVIDE PULL
PULL STRING
STRING IN CONDUIT.
CONDUIT.
PANEL
PANEL K
K
K-21,23,25
K-21,23,25
K-4
K-4
K-6
K-6
33
33
24
24
R
REF
REF
FRZ
12'
12'
J
J
M
33
33
33
33
LOADING
LOADING DOCK
DOCK
1B
SCALE: 3/16" = 1'-0"
0
0
4'
4'
8'
8'
13
13
K-5,7,9
K-5,7,9
11
16'
16'
M
J
K-22
K-22
Revisions
30
30
Drawing Title
SCOPE OF WORK
11
CTR
CTR
J
K-16,18,20
K-16,18,20
CTR
CTR
K-2
K-2
JJ
K-15,17,19
K-15,17,19
11
K-1
K-1
SCALE: 1/8" = 1'-0"
22
22
KITCHEN
KITCHEN
1
11
ELECTRICAL FIRST FLOOR
ENLARGED PLANS
10
10
11
32'
32'
GFCI
CTR
CTR
GFCI
CTR
CTR
GFCI
GFCI
K-3
K-3
SCALE: 1/16" = 1'-0"
16'
16'
Date
29
29
Phase
DW
CONCEPT
A/E Project Number
K-8,10,12
12-0009.015
Date
8'
8'
Description
21
21
GFCI
8'
8'
28
28
IM
GFCI
4'
4'
No.
99
CTR
CTR
0
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
37. NEW 208V, 1ø, 60Hz, 1.35A ENERGY RECOVERY UNIT.
UNIT. PROVIDE
PROVIDE
INTERLOCK
INTERLOCK PER
PER MECHANICAL
MECHANICAL SHEET
SHEET M601.
M601.
M
11
11
0
0
IF
IF THIS
THIS DRAWING
DRAWING IS
IS A
A REPRODUCTION,
REPRODUCTION, GRAPHIC
GRAPHIC SCALE
SCALE MUST
MUST BE
BE USED
USED
2'
2'
NEW
NEW WORK
WORK KEY
KEY NOTES
NOTES
S
S
22
EP101
EP101
KITCHEN
KITCHEN ELECTRICAL
ELECTRICAL PLAN
PLAN -- PROPOSED
PROPOSED
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
W
3/8"
3/8" == 1'-0"
1'-0"
N
N
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
E
E
100%
1:1
Number
EP101
1. CONNECT EXISTING 3#3AWG + #8G FEEDERS TO PANEL A.
2. CONNECT EXISTING 2 SETS 4#3/0AWG + #3G FEEDERS TO PANEL K.
SCALE: 1-1/2" = 1'-0"
2. NEW 120/208V, 400A PANELBOARD K. CONNECT EXISTING 2 SETS OF #3/0
FEEDERS TO PANEL K. COORDINATE WALL DIMEMSIONS WITH THE NEW
PANEL PRIOR TO PURCHASING.
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
60A
3ø
1
2
EMERGENCY
PANEL
SCALE: 1/2" = 1'-0"
0
1'
2'
4'
0
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
SCALE: 1" = 1'-0"
1'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
2'
0 1/2'
#
1. NEW 120/208V, 100A MAINS, 70A MCB, PANELBOARD A. CONNECT
EXISTING #3AWG FEEDERS TO PANEL A. COORDINATE WALL DIMENSION
WITH THE NEW PANEL PRIOR TO ORDERING.
2'
0
1'
NEW WORK KEY NOTES
100
3 Ø, 4
W
MLO
1
MDP
PANEL M
PANEL B
PANEL OL
PANEL G
PANEL A
PANEL K
PANEL F
CT
A
120 / 208 V
A
1200
M
120 / 208 V
3 Ø, 4
W
MLO
400
A
120 / 208 V
3 Ø, 4
MLO
W
400
A
120 / 208 V
3 Ø, 4
MLO
W
60
A
120 / 208 V
3 Ø, 4
MLO
W
225
A
120 / 208 V
3 Ø, 4
MLO
W
100
A
120 / 208 V
3 Ø, 4
W
70A MCB
400
A
120 / 208 V
3 Ø, 4
W
350A MCB
100
A
120 / 208 V
3 Ø, 4
W
MLO
ELECTRICAL RISER DIAGRAM
1/8" = 1'-0"
SCALE: 1/4" = 1'-0"
SCALE: 3/16" = 1'-0"
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
No.
Description
Date
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
EP501
Revisions
Drawing Title
ELECTRICAL RISER DIAGRAM
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL SHEET NOTES
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
1:1
Number
EP501
2'
SCALE: 1-1/2" = 1'-0"
SCALE: 1" = 1'-0"
3'
0 1/2'
1'
2'
0
1'
Location:
Supply From:
Mounting:
Enclosure:
Branch Panel: K
Mechanical Room
Panel B
Recessed
Type 1
Volts: 120/208 Wye
Phases: 3
Wires: 4
10kA
MCB
150 A
70 A
Location:
Supply From:
Mounting:
Enclosure:
SCALE: 3/4" = 1'-0"
KITCHEN
MDP
Recessed
Type 1
Volts: 120/208 Wye
Phases: 3
Wires: 4
A.I.C. Rating: 10kA
Mains Type: MLO
Mains Rating: 400 A
Notes:
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
Circuit Description
RECEPTACLE - MULTIPURPOSE ROOM
REFRIGERATOR - MULTIPURPOSE ROOM
RECEPTACLE - CONFERENCE ROOM
GFCI RECEPTACLE - BATHROOM
LIGHTING - MULTIPURPOSE ROOM
LIGHTING - CONFERENCE ROOM
OPEN COIL DUCT HEATER - PH-1
Trip Poles
A
15 A
1
1080 VA 656 VA
20 A
1
15 A
1
20 A
1
180 VA 2080 VA
15 A
1
15 A
1
20 A
1
700 VA 325 VA
FCU-1, 2, 3, 4, 5
-ELECTRIC HEATER - CUH-2
-ELECTRIC HEATER - CUH-2
--
20 A
-15 A
-15 A
--
B
1265 VA
160 VA
C
540 VA
540 VA
360 VA
464 VA
325 VA
145 VA
750 VA
2080 VA
750 VA
2
-2
-2
--
145 VA
375 VA
375 VA
375 VA
375 VA 1200 VA
Poles
1
1
1
2
-2
-2
-2
-1
Trip
20 A
15 A
15 A
30 A
-15 A
-15 A
-15 A
-15 A
Circuit Description
REFRIGERATOR - MULTIPURPOSE ROOM
RECEPTACLE - CONFERENCE ROOM
RECEPTACLE - CONFERENCE ROOM
WASHING MACHINE
-ENERGY RECOVERY UNIT - ERU-1
-ELECTRIC HEATER - CUH-1
-ELECTRIC HEATER - CUH-2
-MICROWAVE - RECEPTACLE
375 VA
375 VA
5916 VA
52 A
5920 VA
52 A
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
Circuit Description
RECEPTACLE - KITCHEN
RECEPTACLE - KITCHEN
ICE MACHINE
--HOOD EF-1 & DISHWASHER EF-2
-ELECTRIC Duct Heater - EDH-1
--RANGE
--OUTDOOR CONDENSING UNIT - CU-2
--
4159 VA
35 A
Trip Poles
A
20 A
1
1500 VA 1500 VA
20 A
1
20 A
3
--- 1165 VA 5404 VA
--20 A
2
--- 1014 VA 964 VA
70 A
3
----- 6667 VA 990 VA
70 A
3
----- 8406 VA 3900 VA
40 A
2
---
31509 VA
266 A
Total Load:
Total Amps:
Legend:
2'
1'
0
A.I.C. Rating:
Mains Type:
Mains Rating:
MCB:
Notes:
Total Load:
Total Amps:
B
C
1500 VA
656 VA
1165 VA 1265 VA
1165 VA
5404 VA
1014 VA 5404 VA
6667 VA
990 VA
6667 VA 990 VA
8406 VA
500 VA
8406 VA 3900 VA
Poles
1
1
1
3
--1
3
--1
2
--
Trip
20 A
20 A
20 A
50 A
--15 A
20 A
--20 A
40 A
--
Circuit Description
RECEPTACLE - KITCHEN
REFRIGERATOR
FREEZER
DISH WASHER
--Lighting - KITCHEN
SUPPLY FAN - SF-1
--MOTORIZED DAMPER
OUTDOOR CONDENSING UNIT - CU-1
--
3770 VA
3770 VA
29057 VA
242 A
32580 VA
275 A
Load Classification
Power
Motor
Largest Motor
Connected Load
5100 VA
232 VA
58 VA
Demand Factor
100.00%
100.00%
125.00%
Estimated Demand
5100 VA
232 VA
73 VA
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn. Current:
Total Est. Demand Current:
Load Classification
Power
Motor
Largest Motor
15995 VA
16009 VA
44 A
44 A
Connected Load
25498 VA
7540 VA
7800 VA
Demand Factor
100.00%
100.00%
125.00%
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
Legend:
Estimated Demand
25498 VA
7540 VA
9750 VA
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn. Current:
Total Est. Demand Current:
93146 VA
95096 VA
259 A
264 A
Notes:
SCALE: 1/2" = 1'-0"
Branch Panel: B
Location:
Supply From:
Mounting:
Enclosure:
8'
0
1'
2'
4'
Notes:
WIRE SCHEDULE
ELETRIC ROOM
MDP
Surface
Type 1
Volts: 120/208 Wye
Phases: 3
Wires: 4
A.I.C. Rating: 10kA
Mains Type: MLO
Mains Rating: 400 A
MCB Rating:
BREAKER
SIZE
SCALE: 1/4" = 1'-0"
SCALE: 3/16" = 1'-0"
SCALE: 1/8" = 1'-0"
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
Circuit Description
Space
HVAC MECH ROOM 2
--STAIRWELL STORAGE HEATER
--OUTSIDE UNIT HVAC
--ELEVATOR ROOM FAN
ELEVATOR ROOM LIGHTS
AUTO DOOR OPENERS
ELEVATOR CAB LIGHTS
AIR CURTAIN
--SCREEN PROJECTORS
*PANEL A
--PANEL D
---
Trip Poles
A
B
C
Poles Trip
Circuit Description
--0 VA
20 A
3
360 VA
--360 VA
--360 VA
60 A
3
3600 VA
0 VA
--- Space
--3600 VA 2400 VA
3
20 A HVAC MECH ROOM 1
--- 3600 VA 2400 VA
--- -60 A
3
3600 VA 2400 VA
--- ---3600 VA 1080 VA
1
20 A RECPT SNACK/ RECPT ROOM A
--- 3600 VA 1080 VA
1
20 A LOAD
20 A
1
500 VA
1200 VA
1
20 A LIGHTS LOBBY
20 A
1
500 VA 1080 VA
1
20 A RECPT
20 A
1
500 VA 1080 VA
1
20 A RECPT
20 A
1
500 VA
750 VA
2
20 A ELEVATOR ROOM HEATER
50 A
3
3000 VA 750 VA
--- ---- 3000 VA 667 VA
3
20 A OUTSIDE HVAC UNIT
--3000 VA
667 VA
--- -20 A
1
500 VA 667 VA
--- -70 A
3
6125 VA 2592 VA
3
100 A PANEL G
--6125 VA 2592 VA
--- ---6125 VA 2592 VA
--- -200 A
3
12000... 5712 VA
3
175 A ELEVATOR
--12000 VA 5712 VA
--- ---12000 VA 5712 VA
--- -Total Load:
Total Amps:
42716 VA
356 A
43006 VA
359 A
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
WIRE
SIZE
RATING
20
12AWG
25
1
12AWG
3/4" C
30
10AWG
35
1
10AWG
3/4" C
40
8AWG
50
1
10AWG
3/4" C
50
8AWG
50
1
10AWG
1" C
70
4AWG
85
1
8AWG
1" C
100
3AWG
100
1
8AWG
1-1/2" C
SETS
GROUND
SIZE
RACEWAY
SIZE
REMARKS
Professional Certification.
I certify that these documents
were prepared or approved by
me, and that I am a duly licensed
professional engineer under the
laws of the State of Maryland.
License number 45772,
Expiration date 07.28.2016
*ALL WIRES SHALL BE THWN, 75C, COPPER
No.
Description
Revisions
43966 VA
367 A
Drawing Title
Load Classification
Power
Motor
Connected Load
129687 VA
0 VA
Demand Factor
100.00%
0.00%
Estimated Demand
129687 VA
0 VA
ELECTRICAL PANEL
SCHEDULES
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn. Current:
Total Est. Demand Current:
129687 VA
129687 VA
360 A
360 A
Phase
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
16'
Date
8'
Date
Legend:
32'
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
Notes:
2#3/0AWG
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
Branch Panel: A
Notes:
CIRCUIT DESCRIPTION WITH " * " NEXT TO DESCRIPTION HAVE A REVISED LOAD
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
JO
Checked By
AM
Sheet
1:1
Number
EP601
GENERAL NOTES
MECHANICAL ABBREVIATIONS
MECHANICAL SYMBOLS AND ABBREVIATIONS
ABBR.
SYMBOL
REMARKS
TYPE
HORIZONTALLY MOUNTED EXHAUST/RETURN
AIR REGISTER/GRILLE
CFM
TYPE
VERTICALLY MOUNTED EXHAUST/RETURN
AIR REGISTER/GRILLE
CFM
TYPE
HORIZONTALLY MOUNTED SUPPLY AIR
DIFFUSER/REGISTER/GRILLE
CFM
TYPE
VD
SA
RA
EA
OA
* SA
* RA
* RA
* EA
* EA
* OA
* OA
24X12
BRITISH THERMAL UNITS PER HOUR
CFM
CUBIC FEET PER MINUTE
CUH
CABINET UNIT HEATER
CU
CONDENSING UNIT
DIA
DIAMETER
SYMBOL
INSTALL COMPLETE AND OPERATE MECHANICAL SYSTEMS AS INDICATED ON THE
REMARKS
DISCONNECT FROM EXISTING
DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE.
2.
DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT NECESSARILY SHOW ALL
EXISTING COMPONENTS. COORDINATE INSTALLATION OF NEW EQUIPMENT AND
CONNECTION TO EXISTING
ACCESSORIES WITH EXISTING CONDITIONS. MINOR MODIFICATIONS TO EXISTING
COMPONENTS, AT NO ADDITIONAL COST TO THE GOVERNMENT, MAY BE REQUIRED
AS TO PROVIDE A COMPLETE AND CODE COMPLIANT SYSTEM.
3.
THE GENERAL CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL EXISTING TO
FCU
FAN COIL UNIT
EA
EXHAUST AIR
RECTANGULAR DUCTWORK
SUPPLY/OUTSIDE AIR ELBOW UP
EDH
ELECTRIC DUCT HEATER
EF
EXHAUST FAN
CONTRACTOR BEGIN FABRICATION AND/OR INSTALLATION OF ANY EQUIPMENT/
RECTANGULAR DUCTWORK
SUPPLY/OUTSIDE AIR ELBOW DOWN
EG
EXHAUST GRILLE
DUCTWORK/ PIPING/ ELECTRICAL/ SPRINKLER/ CABLE TRAYS PRIOR TO
ERU
ENERGY RECOVERY UNIT
RECEIVING APPROVED COORDINATION DRAWINGS FROM GOVERNMENT.
RECTANGULAR DUCTWORK
EXHAUST/RETURN/RELIEF AIR ELBOW UP
(E)
EXISTING
F
DEGREE FAHRENHEIT
RECTANGULAR DUCTWORK
EXHAUST/RETURN/RELIEF AIR ELBOW DOWN
FLA
FULL LOAD AMPS
FN
FURNACE
HP
HORSEPOWER
HZ
HERTZ
IN
INCH
IU
INDOOR UNIT
KW
KILOWATT
LBS
POUNDS
SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE
MCA
MINIMUM CURRENT AMPACITY
APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST
REMAIN AND NEW EQUIPMENT, DUCTWORK, HVAC PIPING, PLUMBING PIPING,
SPRINKLER PIPING, ELECTRICAL CONDUITS, CABLE TRAYS ETC WITH RESPECTIVE
TRADES PRIOR TO DEVELOPING COORDINATION DRAWINGS AND SUBMITTING THEM
FOR GOVERNMENT REVIEW AND APPROVAL. UNDER NO CIRCUMSTANCES SHALL THE
4.
INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH
MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS AND APPLICABLE
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
CODES AND REGULATIONS.
5.
PROVIDE VIBRATION ISOLATORS FOR ALL PIPING SUPPORTS CONNECTED TO, AND
WITHIN 50 FT. OF ISOLATED EQUIPMENT THROUGHOUT THE MECHANICAL ROOMS.
6.
COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL,
STRUCTURAL, CIVIL, ELECTRICAL WORK, ETC., SHOWN ON OTHER DRAWINGS.
SUPPLY AIR ( * DUCT SIZE )
RETURN AIR ( * DUCT SIZE )
EXHAUST AIR ( * DUCT SIZE )
OUTSIDE AIR ( * DUCT SIZE )
DEMOLITION
24"Ø
BTUH
ABBR.
PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO
DOWN
VOLUME DAMPER
* SA
REMARKS
1.
DN
VERTICALLY MOUNTED SUPPLY AIR
DIFFUSER/REGISTER/GRILLE
CFM
ABBR.
MECHANICAL SYMBOLS AND ABBREVIATIONS
ROUND DUCT SIZE
RECTANGULAR DUCT SIZE,
FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN
7.
ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING
INSULATION IS APPLIED.
8.
MOCP
MAXIMUM OVERCURRENT PROTECTION
CONDITIONS AND RESULT MUST BE DETERMINED BY THE PROJECT SITE
NC
NOISE CRITERION
CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING
OA
OUTSIDE AIR
INSTALLED. DO NOT SCALE DRAWINGS.
PH
PHASE/ PENTHOUSE
PVC
POLYVINYL CHLORIDE
R
RADIUS
RA
RETURN AIR
RAD
RETURN AIR DUCT
RPM
REVOLUTION PER MINUTE
SA
SUPPLY AIR
SAD
SUPPLY AIR DUCT
SD
SUPPLY DIFFUSER
FALL AND INJURE BUILDING OCCUPANTS. DESIGN ALL EQUIPMENT MOUNTINGS TO
SF
SUPPLY FAN
RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY HORIZONTAL
SG
SUPPLY GRILLE
DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION.
TG
TRANSFER GRILLE
(TYP)
TYPICAL
V
VOLT
W
WIDTH
9.
NIKA A+E
LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
LOCATIONS AND SIZES OF ALL FLOOR, AND WALL OPENINGS SHALL BE
COORDINATED WITH ALL OTHER TRADES INVOLVED.
10.
ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK, PIPING, CONDUIT, ETC SHALL
BE FIRE STOPPED/BLOCKED WITH AN APPROVED PRODUCT.
11.
PROVIDE LAMINATED SHEET IN BINDERS FOR EACH EQUIPMENT SYSTEM CONTROL DIAGRAM AND
SEQUENCE OF OPERATION FOR USE BY FACILITY MAINTENANCE STAFF.
12.
MOUNT ALL OVERHEAD UTILITIES AND OTHER FIXTURES WEIGHING 31 POUNDS OR
MORE (EXCLUDING DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS THAT
COLLECTIVELY EXCEED THAT WEIGHT) TO MINIMIZE THE LIKELIHOOD THAT THEY WILL
THIS STANDARD DOES NOT PRECLUDE THE NEED TO DESIGN EQUIPMENT
MOUNTINGS FOR FORCES REQUIRED BY OTHER CRITERIA SUCH AS SEISMIC
STANDARDS.
13.
REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING AND EQUIPMENT INSTALLATION.
14.
LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT
ACCESS PANELS, CONTROLS AND VALVING.
15.
REPLACE INSULATION ON ALL EXISTING TO REMAIN HVAC PIPING
16.
ADDITIONAL CONTROLS TO BE PROVIDED AS AN EXTENSION OF THE EXISTING
CONTROLS SCHEME AND ARE TO BE INSTALLED BY CONTRACTOR PER
MANUFACTURER'S RECOMMENDATION. DDC CONTROLS ARE TO BE CONNECTED TO
THE CAMPUS CENTRAL WORK STATION AS SHOWN ON CONTROL DIAGRAMS.
17.
ANY WORK TO EQUIPMENT, IT'S ACCESSORIES OR SUPPORTING COMPONENTS
UNDER WARRANTY SHALL BE PROVIDED ONLY BY A CONTRACTOR OR VENDOR THAT
WILL MAINTAIN THE VALIDITY OF THE WARRANTY.
18.
SIZES AND LOCATIONS OF ALL EXISTING EQUIPMENT, DUCTWORK, PIPING,
CONTROLS, SUPPORTS, ELECTRICAL AND APPURTENANCES ARE APPROXIMATE.
CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND START
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
OF WORK. CONTRACTOR SHALL COORDINATE ALL RELATED EFFORTS WITH THE
OWNER.
19.
PROVIDE DRAINS AT ALL LOW POINTS AND AIR VENTS AT ALL HIGH POINTS FOR
No.
Description
Date
HYDRONIC SYSTEMS.
20.
REPAIR/REAPPLY EXISTING INSULATION THAT BECOMES DAMAGED OR REMOVED
DURING CONSTRUCTION.
21.
ALL DUCTWORK, AIR TERMINAL BOXES, DIFFUSERS, GRILLES, PIPING, VALVES, ETC
OUTSIDE OF THE LIMIT OF WORK AREA REPRESENT EXISTING TO REMAIN ITEMS
THAT ARE NOT PART OF THIS CONTRACT. ITEMS ARE INDICATED FOR REFERENCE
ONLY UNLESS NOTED OTHERWISE.
22.
CONTRACTOR SHALL COORDINATE PHASING OF UTILITIES TO MINIMIZE IMPACT ON
SERVICES / FACILITIES TO REMAIN IN OPERATION DURING CONSTRUCTION.
Revisions
23.
USE OF MERCURY THERMOMETERS IS PROHIBITED.
Drawing Title
24.
ALL NEW DUCT AND HYDRONIC SYSTEMS SHALL BE LEAK TESTED.
25.
ALL EXISTING TO REMAIN HOT WATER S & R PIPING, STEAM & CONDENSATE PIPING,
MECHANICAL NOTES AND
SYMBOLS
DRAIN PIPING SHALL BE PROVIDED WITH NEW INSULATION & ALL-SERVICE JACKET.
Phase
CONCEPT
A/E Project Number
12-0009.015
Date
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
UP/FF
Checked By
AK
Sheet
1:1
Number
M001
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
SCALE: 1" = 1'-0"
1'
SCALE: 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
SCALE: 3/16" = 1'-0"
No.
Description
Date
0
Revisions
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
SCALE: 3/4" = 1'-0"
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1'
3'
2
M401
2'
0 1/2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
Drawing Title
SCOPE OF WORK
MECHANICAL FIRST FLOOR
OVERALL PLAN
1
M401
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
1
M100
W
MECHANICAL FIRST FLOOR OVERALL PLAN
3/16" = 1'-0"
N
CADD Plot Scale
Revit Model
Drawn By
FF
Checked By
AK
Sheet
E
100%
1:1
Number
M100
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
SCALE: 1" = 1'-0"
1'
3'
0 1/2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
SCALE: 1/2" = 1'-0"
SCALE: 1/4" = 1'-0"
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
SCALE: 3/16" = 1'-0"
No.
F
TELECOM
EQUIPMENT
RM
1
M402
Drawing Title
SCOPE OF WORK
MECHANICAL SECOND FLOOR
OVERALL PLAN
Phase
32'
CONCEPT
1
SCALE: 1/16" = 1'-0"
16'
M101
8'
Date
Revisions
SCALE: 1/8" = 1'-0"
8'
4'
0
Description
ROOM F
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
1'
2'
DN
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
A/E Project Number
MECHANICAL SECOND FLOOR OVERALL PLAN
12-0009.015
3/16" = 1'-0"
Date
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
FF
Checked By
AK
Sheet
E
100%
1:1
Number
M101
1. FOR ABBREVIATIONS, SYMBOLS AND GENERAL NOTES REFER
TO DRAWING M001.
SCALE: 1-1/2" = 1'-0"
DEMOLITION KEY NOTES
2. REMOVE EXISTING RETURN AIR GRILLE . REBALANCE
THE RETURN GRILLE AS INDICATED ON THE NEW WORK
DRAWING. PROVIDE PRE-CONSTRUCTION TAB MEASUREMENT
FOR THE EXISTING RETURN DIFFUSER TO ENGINEER BEFORE
COMMENCEMENT OF CONSTRUCTION.
SCALE: 1" = 1'-0"
1'
#
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
0
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
UP
2'
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
1. REMOVE SUPPLY AIR DIFFUSER. PROVIDE PRE-CONSTRUCTION
TAB MEASUREMENT FOR THE EXISTING SUPPLY DIFFUSER TO
ENGINEER BEFORE COMMENCEMENT OF CONSTRUCTION.
2'
0
1'
2. PROVIDE PRE-DEMOLITION TAB TO DETERMINE EXISTING
SUPPLY AIR, RETURN, OUTSIDE AND AIR SETTINGS
(E) 6"Ø DRYER
EXHAUST
6"ø
8" ø
8" ø
8"ø
12"x10"
24"x12"
30"x12"
18"x6"
18"x6"
SCALE: 1/2" = 1'-0"
24X24 RA
DIFFUSER
M400
(E) RAD
20x14 RA
DIFFUSER
24"x12"
(E)24X12 RA
DUCT
(E)12X6 SA
DUCT
MECHANICAL FIRST FLOOR APARTMENT- DEMOLITION
3/16" = 1'-0"
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
SCALE: 1/4" = 1'-0"
4'
2'
OFFICE
SMALL
SCALE: 3/16" = 1'-0"
(E) FLUE
GAS
No.
Description
ø
6"
(E) FN-6
14"x6"
18"x12"
(E) KITCHEN HOOD
(E) RAD
18"x12"
2
CAP & SEAL
DUCT
(E) SAD
Revisions
Drawing Title
SCOPE OF WORK
14"x6"
MECHANICAL FIRST FLOOR
ENLARGED PLANS DEMOLITION
1
RELOCATE EXISTING
Phase
32'
CONCEPT
A/E Project Number
SCALE: 1/16" = 1'-0"
16'
12-0009.015
8'
Date
12"x8"
SCALE: 1/8" = 1'-0"
8'
4'
0
(E) COMBUSTION
AIR INTAKE
(E) 24x14 ,
EXHAUST DUCT
UPTO EF-1 LOCATED ON
ROOF.
16'
0
4'
8'
12'
0
(E) SAD
8" ø
1
8'
0
1'
2'
10"x6"
12"x4"
4'
12"x10"
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL NOTES
2
M400
MECHANICAL FIRST FLOOR KITCHEN - DEMOLITION
Date
3/16" = 1'-0"
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
UP/FF
Checked By
AK
Sheet
E
100%
1:1
Number
M400
2. RELOCATE SPRINKLER PIPING AND SPRINKLER HEADS AS
REQUIRED TO ACCOMMODATE THE ERU-1, SUPPLY, RETURN,
OUTDOOR AND EXHAUST AIR DUCTWORK AND ASSOCIATED
ACCESSORIES. THE RELOCATED SPRINKLER PIPING AND
SPRINKLER HEADS TO COMPLY WITH NFPA 13. PROVIDE
SPRINKLER HEADS TO MATCH EXISTING SPRINKLER HEADS.
SCALE: 1-1/2" = 1'-0"
0
1'
1. FOR ABBREVIATIONS, SYMBOLS AND GENERAL NOTES REFER TO
DRAWING M001.
3. COORDINATE THE NEW EQUIPMENT, DUCTWORK, ACCESSORIES,
ETC. WITH EXISTING STRUCTURE AND EXISTING EQUIPMENT,
DUCTWORK, LIGHTS, PIPES, ETC..
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
4. CONNECT THE EXISTING HOOD SYSTEM TO THE EXISTING FIRE
SUPPRESSION SYSTEM.
#
2'
NEW WORK KEY NOTES
SCALE: 1" = 1'-0"
0 1/2'
1'
MAIN LOBBY
10
4. PROVIDE SUPPORTS FOR MOUNTING ERU-1 AS PER
MANUFACTURER'S RECOMMENDATION. PROVIDE SERVICE
CLEARANCE AS REQUIRED.
3'
SCALE: 3/4" = 1'-0"
2'
CAPPED
AND
SEALED
DUCT
CONFERENCE
CUH-2
2
6"x6"
IU-2
IU-3
12"x4"
6"ø
12"x6"
SCALE: 1/2" = 1'-0"
3
OFFICE
LARGE
4"ø
12"x10"
(E) 8" OAD EXISTING
TO REMAIN
OFFICE
SMALL
(E) SAD
CUH-2
IU-5
2
12x6 SAD TO
FLOOR ABOVE
(E) CU
(E)12x4 SAD
TO FLOOR ABOVE
EXISTING TO REMAIN
CU-1
1
30"x12"
(E)18x6 SAD TO FLOOR
ABOVE EXISTING TO
REMAIN
CUH-2
BACKDRAFT
DAMPER
(E) AHU-1
(E) RAD
(E)24x12 RAD FROM
FLOOR ABOVE
EXISTING TO REMAIN
(E) CU
CU-2
12x6 SAD TO
FLOOR ABOVE
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
MECHANICAL FIRST FLOOR - APARTMENT AND BATHROOM - ENLARGED PLAN
3/16" = 1'-0"
SCALE: 3/16" = 1'-0"
No.
(E) 24x14 ,
EXHAUST DUCT
UPTO EF-1 LOCATED ON
ROOF.
ø
6"
8"x8"
(E) FN-6
Revisions
EF-2
SD-2(600)
(TYP. OF 3)
(100)
14"x6"
SCALE: 1/8" = 1'-0"
8'
4'
0
REROUTE SPRINKLER LINE AS
NECESSARY TO PROVIDE
ACCESS TO MECH EQUIPMENTS
M
8
(E)
KITCHEN
HOOD
SCALE: 1/16" = 1'-0"
8'
16'
32'
8"x8"
KITCHEN
MECHANICAL FIRST FLOOR
ENLARGED PLAN
MERV-8
FILTER
HOUSING IN
ATTIC
9
7
16"x12"
Drawing Title
SCOPE OF WORK
5
18"x12"
18"x12"
24"x12"
DW
1
5
8"x8" DN. TO
DISHWASHER
HOOD
24"x12"
Phase
UPTO 24"x12"
GOOSENECK
ON ROOF
SF-1 IN
ATTIC
CONCEPT
A/E Project Number
12-0009.015
M
Date
24"x12"
ELECTRIC
DUCT HEATER
EDH-1 IN ATTIC
24"x12"
S
6
35%
60%
90%
M401
MECHANICAL FIRST FLOOR - KITCHEN - ENLARGED PLAN
E
W
3/16" = 1'-0"
N
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
UP/FF
Checked By
AK
Sheet
2
Date
14"x14" EA
LOUVER
12"x8"
(E)18x12 RA
DUCT FROM
DAYCARE
Description
(E) COMBUSTION
AIR INTAKE
(E) FLUE
GAS
(E)12x6 SA
DUCT TO
DAYCARE
16'
0
4'
8'
12'
M401
(E)18x6 SAD TO
FLOOR ABOVE
EXISTING TO REMAIN
(E) SAD
MIN 10' APART
1
(E) SAD
(E) SAD
BACKDRAFT
DAMPER
T
MECH
RM.
24"x12"
(E) SAD
6"ø
PH-1
4
IU-4
3
ERV-1
12x6 SAD TO
FLOOR ABOVE
SCALE: 1/4" = 1'-0"
6"x4"
9. CONTRACTOR TO FIELD VERIFY THAT THE FIRE SUPPRESSION
SYSTEM IS CONNECTED TO FIRE ALARM.
12"x6"
STORAGE
6"x4"
EG-1(75)
T
6"ø
T
8. EXISTING FURNACE FN-6 TO BE REBALANCED TO THE ORIGINAL
SUPPLY, RETURN AND OUTDOOR AIR. EQUALLY DISTRIBUTE
THE CFM OF REMOVED KITCHEN RETURN GRILLE TO ALL
RETURN GRILLES ASSOCIATED WITH EXISTING FURNACE FN-6.
12"x6"
T
4'
2'
1'
EG-1(30)
(E) EXHAUST DUCT
IU-1
3
6"ø
0
7. REBALANCE EXISTING SUPPLY AIR DIFFUSER TO THE CFM INDICATED
ON THE DRAWING .
SD-1(115)
SD-1(120)
6"ø
1'
0
4"Ø DRYER EXHAUST
3
8'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
6. SEAL AND PATCH DUCT PENETRATION UP TO GOOSENECK.
PROVIDE ROOF CURB FOR GOOSENECK TO MATCH EXISTING ROOF
PITCH. REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS.
CUH-1
4'
NIKA A+E
5. PROVIDE SUPPORTS FOR MOUNTING EXHAUST FAN AS PER
MANUFACTURER'S RECOMMENDATION. PROVIDE SERVICE
CLEARANCE AS REQUIRED.
4
2'
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
3. PROVIDE SUPPORTS FOR MOUNTING CASSETTE UNIT AS PER
MANUFACTURER'S RECOMMENDATION. PROVIDE SERVICE
CLEARANCE AS REQUIRED.
ENTRY
0
1. EXISTING AHU-1 SUPPLY FAN TO BE BALANCED TO 1750 CFM BY
ADJUSTING BELTS, SHEAVES, PULLEYS, ETC. AS REQUIRED.
PROVIDE NEW BELTS, SHEAVES, PULLEYS, ETC. AS REQUIRED.
BALANCE THE RETURN AND OUTDOOR AIR TO 1515 CFM AND
235 CFM RESPECTIVELY.
2. PROVIDE PVC/RUBBER MOUNTING PAD FOR MOUNTING
CONDENSING UNIT. REFER TO DETAIL ON DWG. 501 FOR MORE
DETAILS.
UP
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL NOTES
1:1
Number
M401
1. FOR ABBREVIATIONS, SYMBOLS AND GENERAL NOTES REFER TO
DRAWING M001.
SCALE: 1-1/2" = 1'-0"
NEW WORK KEY NOTES
2. RELOCATED THERMOSTAT WITH ALL ASSOCIATED WIRING AND
CONTROLS.
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
SCALE: 1" = 1'-0"
1'
#
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
T
TG-1
(200)
2
SCALE: 1/2" = 1'-0"
2'
1'
0
10"x10"
TELECOM
EQUIPMENT
RM
1515 CFM /24X24 RA
WALL DIFFUSER
REMAIN TO EXIST
SG-2(375)
SG-2(375)
(E) 24X12 RA
DUCT REMAIN
TO EXIST
STORAGE-3
RM
24"x12"
STORAGE-2
RM
SG-1(195)
SG-1(195)
12X6 SA
DUCT FROM
FLOOR BELOW
MECHANICAL SECOND FLOOR - GENERAL PURPOSE - ENLARGED PLAN
3/16" = 1'-0"
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
SCALE: 3/16" = 1'-0"
No.
Description
Date
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
4'
8'
12'
SCALE: 1/4" = 1'-0"
M402
TG-1
(390)
1
12X6 SA
DUCT FROM
FLOOR BELOW
1
8'
4'
2'
TG-1
(390)
F
10"x10"
SG-1(175)
0
ROOM F
24"x12"
TG-1
(200)
SG-1(200)
4'
0
SCALE: 3/4" = 1'-0"
NIKA A+E
1'
3'
UP
2'
0 1/2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
1. REBALANCE WALL MOUNTED RETURN AIR GRILLE TO CFM
INDICATED ON THE DRAWING.
2'
0
1'
2. COORDINATE THE NEW EQUIPMENT, DUCTWORK, ACCESSORIES,
ETC. WITH EXISTING STRUCTURE AND EXISTING EQUIPMENT,
DUCTWORK, LIGHTS, PIPES, ETC..
Revisions
Drawing Title
SCOPE OF WORK
MECHANICAL SECOND FLOOR
ENLARGED PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GENERAL NOTES
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
N
CADD Plot Scale
Revit Model
Drawn By
FF/UP
Checked By
FB
Sheet
E
100%
1:1
Number
M402
HANGER ROD SUPPORTS. SECURE TO
STRUCTURE ABOVE WITH VIBRATION ISOLATORS
(TYP)
INSULATED DRAIN LINE
STANDARD DUCT MADE WATER TIGHT
STIFFNERS MAY BE INSIDE
BUILDING STRUCTURE
MAIN DUCT
ANGLE REVITED OR SPOT
WELDED AS REQUIRED
STRAIGHT
3/8" SCREEN
45
D-3/4 D HEEL R
1/50 - 1/100
CT
DU
INSULATED REFRIGERANT PIPING
3/4 D THROAT
RADIUS
135° MIN.
BRANCH DUCT
SI
BALANCING DAMPER (BD.)
ZE
MAY BE USED ANYWHERE
+
MAX (27")700 mm
%
25
R
R = W/2
MAIN DUCT
12" MIN.
FLASHING
(BY OTHERS)
18" MIN.
1
M501
INTEGRAL CONDENSATE
PUMP
CASSETTE1UNIT DETAIL
M501
INSULATED
BRANCH DUCT
W
SPECIFIED
DUCT SIZE
2
N.T.S.
6"
ROOFING
(BY OTHERS)
8" MIN.
ACCESS PANEL TO ELECTRICAL, COIL
CONNECTIONS, AND MOTOR/FAN
ASSEMBLY
45
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
BALANCING DAMPER (BD.)
GOOSNECK DETAIL 1
USE ONLY AT LAST TAKEOFF BEFORE OUTLETS &
THEN ONLY WHERE RECTANGULAR RUNOUTS ARE
INDICATED ON DRAWINGS
N.T.S.
POWER TO INDOOR
UNIT
REFRIGERANT
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
NIKA A+E
LINES
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
MAIN DUCT
AIRFLOW
45
EXIST. CONC.
BALCONY
6"
BRANCH DUCT
PVC/RUBBER MOUNTING PAD
RECTANGULAR
15°M
AX
.
BALANCING DAMPER (BD.)
ROUND
AIRFLOW
3/8" DIA. HILTI HY 70 ADHESIVE ANCHOR.
3" EMBEDMENT INTO PVC/RUBBER PAD @
ALL FOUR CORNERS
CONDENSER MOUNTED DETAIL
15°MA
X.
N.T.S.
THIS CONNECTION SHALL BE USED AT ALL BRANCHES FROM MAINS AND
SUB-MAINS. BALANCING DAMPERS SHALL BE PROVIDED AS SHOWN IN
ADDITION TO THOSE INDICATED ON THE PLANS.
TYPICAL DUCTWORK TRANSITION PLAN OR SIDE VIEW
SUPPORT RODS TO
STRUCTURE
NOTE:
UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY.
THE VMC GROUP ISOLATION HANGER
5
M501
FAN
DUCT
6
M501
SUPPLY DUCTWORK TAKE-OFFS
N.T.S
TYPICAL DUCTWORK TRANSITION
N.T.S.
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
DUCT
ELEVATION
FAN
DUCT
DUCT
PLAN VIEW
SEE SPECIFICATIONS FOR
CLAMPS AND SEALANT (TYP.)
NOTE:
FAN REQUIRES POSITIVE ATTACHMENT TO SUPPORTING CHANNELS OF ANGELS.
4
M501
IN-LINE FAN DETAIL
FLEXIBLE DUCT SIZE
SAME AS DIFFUSER
INLET: 1500 mm MAX
LENGTH.
N.T.S
DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS
THE NIPPLE ON THE DRAIN PAN
No.
BRANCH DUCT
SUPPLY OR RETURN, FOR
THERMAL INSULATION SEE
SPECIFICATIONS
SUPPORT SADDLE
FROM STRUCTURE
Date
CONICAL OUTLET
USE RIGID ELBOWS
FOR CHANGE OF
DIRECTION GREATER
THAN 45°
PITCH DOWN
TOWARD DRAIN
Description
R SHALL
EQUAL
OR BE
GREATER
THAN W.
W
CLEAN OUT
Revisions
Drawing Title
A
3
M501
USE ONLY AT LAST TAKEOFF BEFORE OUTLETS &
THEN ONLY WHERE ROUND RUNOUTS ARE
INDICATED ON DRAWINGS
PEN DRAIN
SEE CONTINUATION IN
PLUMBING DRAWING
SHEET METAL
SADDLE
DRAIN PAN
MECHANICAL DETAILS
VOLUME DAMPER W/
LOCKING QUAD
Phase
CONCEPT
OPEN DRAIN
UNIT TYPE
DRAW THRU
A
B
1" PLUS X
X
STANDARD RADIUS
ELBOW
CEILING
NOTE:
NOTE:
1. REFER TO STRUCTURAL DRAWINGS FOR SEISMIC SUPPORT REQUIREMENTS.
Date
THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.
ALL STANDARD RADIUS ELBOWS SHOWN ON FLOOR PLANS MAY BE MADE
SHORT RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE
VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS
RECOMMENDED BY SMACNA.
WHERE X = STATIC PRESSURE IN PAN
7
M501
CASSETTE UNIT DRAIN TRAP DETAIL
N.T.S
A/E Project Number
12-0009.015
1.
2.
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
8
TYPICAL CEILING SUPPLY OR RETURN AIR DEVICE
N.T.S.
9
M501
DUCTWORK RADIUS ELBOWS
N.T.S
CADD Plot Scale
Revit Model
Drawn By
FF/UP
Checked By
AK
Sheet
M501
100%
R
TYPICAL
DIFFUSER OR
REGISTER IN
CEILING.
35%
1:1
Number
M501
DUCT HEATER SCHEDULE
INDOOR DESIGN CONDITIONS
SUMMER (°F)
WINTER
(°F)
RELATIVE HUMIDITY
(%)
70
30 - 65
75
OUTDOOR DESIGN CONDITIONS
COOLING DB (°F)
COOLING WB
(°F)
94.3
HEATING DB
(°F)
75.1
MARK
LOCATION
SYSTEM
EDH-1
1ST FLOOR
ELECTRIC
PH-1
1ST FLOOR
ELECTRIC
AIR FLOW
(CFM)
VOLT
PH
HZ
HEATING CAPACITY
(KW)
MANUFACTURER
MODEL
FINNED TUBE DUCT
HEATER
1800
208
3
60
20
MARLEY
1,2,3,5
OPEN COIL DUCT
HEATER
105
120
1
60
0.7
MARLEY
1,2,4,6
TYPE
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
NOTES:
1.
2.
3.
4.
5.
6.
7.
16.3
PROVIDE SUPPORTS TO MOUNT THE ELECTRIC DUCT HEATER AS PER MANUFACTURER'S RECOMMENDATION.
BALANCE TO AIRFLOW INDICATED ON FLOORS PLANS.
PROVIDE SCR CONTROLLER. SET THE DUCT MOUNTED THERMOSTAT TO 60 F (ADJUSTABLE).
PROVIDE TWO STAGE HEATER WITH DUCT MOUNTED CONTROLLER.
INTERLOCK DUCT HEATER UH-1 WITH EXHAUST FAN SF-1.
INTERLOCK DUCT HEATER PH-1 WITH ERV-1. SET THE DUCT MOUNTED THERMOSTAT TO 20 F (ADJUSTABLE).
PROVIDE DUCT MOUNTED THERMOSTAT.
ENERGY RECOVERY VENTILATOR SCHEDULE
MARK
SERVICE
CONFERENCE ROOM
LARGE OFFICE
ERV-1
LOCATION
SUPPLY EXHAUST
VOLUME VOLUME
(CFM)
(CFM)
SIZE
(IN)
CEILING
35"LX40"WX13"H
105
105
OUTSIDE AIR
WINTER
SUPPLY AIR
SUMMER
WINTER
ROOM AIR
SUMMER
WINTER
SA/EA MOTOR DATA
EFFICIENCY
TEMPERATURE
RECOVERY
SUMMER
14°F 10% RH 95°F 50% RH 58°F 40% RH 79°F 62% RH 70°F 40% RH 75°F 50% RH
ENTHALPY
COOLING
81/79%
ENTHALPY
HEATING
63/61%
79/77%
INPUT
WATT
ESP
67/82
0.06/0.08
ELECTRICAL
V / PH / Hz
208/1/60
BASIS OF
DESIGN
MITSUBISHI
LOSSNAY
NOTES
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
1,2,3,4,5,6,7
NOTES:
1.
2.
3.
4.
5.
6.
7.
PROVIDE SUPPORTS AND INSTALL THE ENERGY RECOVERY UNIT ABOVE CEILING AS PER MANUFACTURER'S RECOMMENDATION..
INSTALL ENERGY RECOVERY UNIT IN THE CEILING WITH ACCESSIBLE SERVICE CLEARANCE AS PER MANUFACTURE'S RECOMMENDATION.
ERU-1 SHALL BE OPERATIONAL DURING USER DEFINED OCCUPIED HOURS.
ERV-1 SHALL BE CONTROLLED BY CONTACT CLOSURE FROM AN EXTERNAL TIMER.
PROVIDE BACKDRAFT DAMPER ON THE OUTDOOR AIR INTAKE AND EXHAUST AIR OUTLET.
ENERGY RECOVERY UNIT SUPPLY AND EXHAUST FANS SHALL BE BALANCED TO THE CFM INDICATED ABOVE IN THE SCHEDULE.
PROVIDE 1 YEAR MANUFACTURER'S PARTS, DEFECTS, & LABOR WARRANTY; FOR ENERGY TRANSFER CORE, PROVIDE 10 YEAR WARRANTY AGAINST DEFECTS IN MATERIAL
AND WORKMANSHIP.
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
CASSETTE SPLIT SYSTEM HEAT PUMP SCHEDULE (EVAPORATOR UNIT)
SUPPLY FAN
SPACE
SERVED
TAG
CU-1
AIR
VOLUME
(CFM)
TYPE
OUTSIDE
AIR
(CFM)
DX COOLING COIL
FAN MOTOR
SELECTED
SPEED
V / PH / HZ
MCA
FLA
TOTAL
COOLING
CAPACITY
(BTUH)
ENT. AIR
TOTAL
HEATING
CAPACITY
(BTUH)
LVG. AIR
DB
(°F)
WB
(°F)
DB
(°F)
WB
(°F)
BASIS OF DESIGN:
MANUFACTURER /
MODEL
NOTES
IU-1
STORAGE - OFFICE
CEILING MOUNTED
350
30
MEDIUM
208 / 1 / 60
1.0
0.28
11,650
10,440
80
67
55
54
MITSUBISHI
SLZ-KA12NA
1,2,3,4,5,6,7
IU-2
CONFERENCE RM
CEILING MOUNTED
320
40
MEDIUM
208 / 1 / 60
1.0
0.23
8,822
8,365
80
67
55
54
MITSUBISHI
SLZ-KA09NA
1,2,3,4,5,6,7
IU-3
CONFERENCE RM
CEILING MOUNTED
320
35
MEDIUM
208 / 1 / 60
1.0
0.23
8,822
8,365
80
67
55
54
MITSUBISHI
SLZ-KA09NA
1,2,3,4,5,6,7
IU-4
LARGE OFFICE
CEILING MOUNTED
320
30
MEDIUM
208 / 1 / 60
1.0
0.23
8,822
8,365
80
67
55
54
MITSUBISHI
SLZ-KA09NA
1,2,3,4,5,6,7
IU-5
SMALL OFFICE
CEILING MOUNTED
320
15
MEDIUM
208 / 1 / 60
1.0
0.23
8,822
8,365
80
67
55
54
MITSUBISHI
SLZ-KA09NA
1,2,3,4,5,6,7
CU-2
NOTES:
WALL MOUNTED ELECTRIC HEATER SCHEDULE
MARK
CUH-1
CUH-2
LOCATION
1ST FLOOR
1ST FLOOR
SYSTEM
ELECTRIC
ELECTRIC
AIR FLOW
(CFM)
TYPE
RECESSED
65
RECESSED
65
VOLT
PH
208
HZ
1
208
60
1
60
HEATING
CAPACITY
(KW)
1.5
0.75
MANUFACTURER
MARLEY
MARLEY
1.
REFRIGERANT R-410A.
2.
EVAPORATOR UNIT FAN SHALL HAVE LOW, MEDIUM, AND HIGH SETTINGS WITH ON/OFF CAPABILITY.
3.
PROVIDE UNIT DISCONNECT SWITCH.
4.
PROVIDE CONDENSATE HIGH LEVEL SAFETY SWITCH TO TURN OFF THE CASSETTE UNIT.
5.
6.
PROVIDE UNIT WITH MERV 8 AIR FILTER.
PROVIDE 7 DAY PROGRAMMABLE WALL MOUNTED THERMOSTAT.
PROVIDE SUPPORTS WITH VIBRATION ISOLATORS AND INSTALL WITH SERVICE ACCESS THE CASSETTE UNITS ABOVE CEILING AS PER MANUFACTURER'S RECOMMENDATION.
SPLIT SYSTEM HEAT PUMP SCHEDULE (CONDENSING UNIT)
MODEL
1,2,3,4
TOTAL
COOLING
CAPACITY
RANGE
(BTUH)
TAG
1,2,3,4
TOTAL
HEATING
CAPACITY
RANGE
(BTUH)
UNIT ELECTRICAL DATA
MIN.
SEER
V/PH/HZ
MCA
MOCP
COMPRESSOR
CONDENSER
FAN MOTOR
(FLA)
BASIS OF DESIGN:
MANUFACTURER /
MODEL
CU-1
28,400
28,600
18
208/1/60
30
40
1
1.9
MITSUBISHI
MXZ-3C30NAHZ
1,2,3,4,5,6
CU-2
18,000
22,000
17
208/1/60
29
40
1
1.9
MITSUBISHI
MXZ-2C20NAHZ
1,2,3,4,5,6
NOTES:
1.
2.
3.
4.
PROVIDE UNIT MOUNTED THERMOSTAT.
PROVIDE THERMAL OVERHEAT PROTECTION.
PROVIDE DISCONNECT SWITCH.
COLOR OF THE GRILLE TO BE APPROVED BY THE ARCHITECT.
TYPE
SERVICE
AIRFLOW
(CFM)
No.
NOTES
1.
AIR DEVICE SCHEDULE
TAG
NOTES
NECK SIZE
(IN)
SIZE
MAX
NC
AIRFLOW
PATTERN
BASIS
OF
DESIGN
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
REFRIGERANT R-410A.
6.
Description
Date
PROVIDE MOUNTAING PAD AS PER MANUFACTURE'S RECOMMENDATION.
2.
PROVIDE UNIT DISCONNECT SWITCH.
3.
PROVIDE REFRIGERANT LINE SETS BETWEEN OUTDOOR AND INDOOR UNIT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
4.
HEAT PUMP.
5.
PROVIDE LOW AMBIENT KIT.
NOTES
FAN SCHEDULE
MOTOR
SD-1
4 WAY
DIFFUSER
SUPPLY
0-120
6Ø
12x12
30
4-WAY
TITUS TMS
1,2,3,4,5
SD-2
4 WAY
DIFFUSER
SUPPLY
121-600
12Ø
24x24
30
4-WAY
TITUS PAS
1,2,3,4,5,6
SUPPLY
0-200
8x6
10x8
30
SINGLE
DEFLECTION
TITUS 301FS
1,2,3,4,5
SUPPLY
201-400
10x10
12x12
30
SINGLE
DEFLECTION
TITUS 301FS
1,2,3,4,5
SG-1
SG-2
TG-1
EG-1
SUPPLY GRILLE
SUPPLY GRILLE
TRANSFER GRILLE
EXHAUST GRILLE
TAG
TYPE
EF-1
UPBLAST
EF-2
INLINE
SERVICE
LOCATION
AIRFLOW
(CFM)
TOTAL SP
(IN. WG.)
DRIVE
RPM
ROOF
1800
0.7
BELT
1595
1/2
1ST FLOOR
300
0.4
DIRECT
1468
1/6
HP
VOLT
PH
Hz
WEIGHT
(LBS)
1725
208
1
60
65
GREENHECK
CUBE-131-5
2,3,6
1725
208
1
60
41
GREENHECK
SQ-85-VG
1,2,4
RPM
MANUFACTURER
NOTES
Revisions
Drawing Title
TRANSFER
EXHAUST
0-390
0-100
10x10
6x4
12x12
12x12
30
30
-
TITUS PAR
TITUS PAR
COOKING HOOD
DISHWASHER
NOTES:
PROVIDE FRAME AND / OR ACCESSORIES AS REQUIRED TO MATCH CEILING / WALL TYPE.
BALANCE TO AIRFLOW INDICATED ON FLOORS PLANS.
UNLESS OTHERWISE INDICATED ON THE FLOOR PLANS, DUCT RUNOUTS SHALL MATCH AIR DEVICE NECK.
PROVIDE SQUARE TO ROUND ADAPTERS AS REQUIRED.
ALUMINUM CONSTRUCTION.
DIFFUSER TO BE IN CONFORMANCE TO NSF.
MECHANICAL SCHEDULES
Phase
SF-1
INLINE
-
-
KITCHEN
1ST FLOOR
1800
1.9
BELT
2270
1 1/2
1725
208
3
60
95
GREENHECK
-
-
-
-
-
-
-
-
-
-
-
-
BSQ-120-15
1,2,3,4,5
-
CONCEPT
1,2,5
1,2,3,4,5
-
A/E Project Number
12-0009.015
Date
NOTES.
1.
2.
3.
4.
5.
6.
MODEL
1.
PROVIDE SUPPORTS WITH VIBRATION ISOLATORS TO MOUNT THE FANS AS PER MANUFACTURER'S RECOMMENDATION
2.
PROVIDE UNIT DISCONNECT SWITCH.
3.
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
UP/FF
EXHAUST FAN EF-1 TO BE INTERLOCKED WITH EXISTING KITCHEN HOOD. PROVIDE MANUAL ON-OFF HOOD SWITCH. PROVIDE ADEQUATE QUANTIY OF RELAYS TO ENERGIZE THE EXHAUST
FAN EF-1 WHEN KITCHEN HOOD IS ON AND VICE VERSA.
Checked By
AK
4.
EXHAUST FAN EF-2 TO BE INTERLOCKED WITH DISHWASHER HOOD. PROVIDE MANUAL ON-OFF HOOD SWITCH. PROVIDE ADEQUATE QUANTIY OF RELAYS TO ENERGIZE THE
EXHAUST FAN EF-2 WHEN DISHWASHER HOOD IS ON AND VICE VERSA.
Sheet
5.
KITCHEN MAKE UP AIR FAN SF-1 TO BE INTERLOCKED WITH EXHAUST FAN EF-1. KITCHEN MAKE UP AIR FAN SF-1 SHALL ENERGIZE AFTER EXHAUST FAN EF-1 IS ENERGIZED.
.
EXHAUST FAN EF-1 TO BE INSTALLED ON EXISTING ROOF CURB. CONTRACTOR TO VERIFY THE SIZE AND OPERING OF THE EXISTING ROOF CURB BEFORE ORDERING THE EXHAUST FAN.
6.
1:1
Number
M601
PIPING
PIPING SYMBOLS
SYMBOLS
CW
NEW DOMESTIC
DOMESTIC COLD WATER
WATER (CW)
NEW
HW
NEW
NEW DOMESTIC HOT WATER (HW)
HWR
NEW DOMESTIC HOT WATER RETURN (HWR)
NEW SANITARY PIPE (SAN)
ABBREVIATIONS
ABBREVIATIONS
AP
ACCESS PANEL
ABV
ABOVE
AFF
ABOVE
ABOVE FINISH
FINISH FLOOR
BEL
BELOW
BELOW
BFPR
BACKFLOW PREVENTER
BV
BALANCING VALVE
NEW VENT PIPE
PIPE (V)
CLG
CEILING
G
NATURAL GAS PIPE
NEW NATURAL
CO
CLEANOUT
P
P
PROPANE GAS PIPE
PROPANE
(E)
EXISTING
FCO
FLOOR CLEANOUT
FD
FLOOR DRAIN
DHWT
DOMESTIC HOT WATER TANK
NEW SHUT-OFF VALVE
HB
HOSE
HOSE BIBB
BIBB
DEMOLITION WORK
OHB
OPEN HUB
HUB DRAIN
DRAIN
OPEN
SP
SOIL PIPE
SS
SOIL STACK
TP
TRAP PRIMER
PRIMER
V
VENT
VENT
VP
VENT
VENT PIPE
VS
VENT STACK
VENT
VTR
VENT
VENT THRU
THRU ROOF
ROOF
O
O
FUEL OIL PIPE
TP
TP
TRAP PRIMER PIPE
CW
EXISTING
EXISTING DOMESTIC
DOMESTIC COLD
COLD WATER
WATER (CW)
(CW)
HW
EXISTING
EXISTING DOMESTIC
DOMESTIC HOT WATER
WATER (HW)
HWR
EXISTING DOMESTIC HOT WATER RETURN
RETURN (HWR)
(HWR)
EXISTING
EXISTING SANITARY PIPE (SAN)
EXISTING VENT PIPE (V)
EXISTING SHUT-OFF VALVE
NG
NATURAL GAS
GAS PIPE
NATURAL
LP
LIQUID PROPANE
PROPANE PIPE
GENERAL
GENERAL SYMBOLS
SYMBOLS
CONNECT
CONNECT NEW
NEW TO
TO EXISTING
PLUMBING
PLUMBING GENERAL
GENERAL NOTES:
NOTES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE SITE AND VERIFYING ALL EXISTING
FIELD CONDITIONS PRIOR TO SUBMISSION
SUBMISSION OF
OF HIS
HIS BID.
BID.
POINT OF DISCONNECT
ELBOW
ELBOW DOWN
2. CONTRACTOR IS RESPONSIBLE
RESPONSIBLE FOR
FOR COORDINATING
COORDINATING HIS
HIS WORK
WORK WITH THE
THE WORK OF ALL
OTHER
OTHER TRADES
TRADES AND
AND MAKING
MAKING ANY
ANY NECESSARY
NECESSARY MODIFICATIONS
MODIFICATIONS TO HIS WORK AT NO ADDITIONAL
COST, INCLUDING ALL OFFSETS.
ELBOW UP
CONNECTION, 45°
45° OR
OR 90°
TOP CONNECTION,
SHUT
SHUT OFF VALVE
GAS SHUT OFF VALVE
BOTTOM CONNECTION,
CONNECTION, 45°
45° OR
OR 90°
BOTTOM
TP
4. CONTRACTOR SHALL REMOVE EXISTING EQUIPMENT AND MATERIALS PERTAINING TO
HISCONTRACT
HISCONTRACT AS
AS SPECIFIED OR AS REQUIRED WHETHER SHOWN ON THE DRAWINGS OR NOT,
TO PREPARE
PREPARE FOR
FOR THE
THE NEW
NEW WORK.
WORK.
5. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH LOCAL CODES. THESE CODES
SHALLBE
SHALLBE FOLLOWED
FOLLOWED AS MINIMUM PROVIDING HIGHER
HIGHER GRADES
GRADES OF
OF MATERIAL AND
WORKMANSHIP WHERE REQUIRED BY THESE DOCUMENTS.PROVIDE
DOCUMENTS.PROVIDE ALL
ALL TESTS
TESTS REQUIRED
REQUIRED BY
LOCAL CODES.
SIDE CONNECTION
6. CITY OF GAITHERSBURG
GAITHERSBURG WILL REIMBURSE
REIMBURSE ALL PERMITTING
PERMITTING FEES TO THE CONTRACTOR.
RISE OR DROP IN PIPE
7. SUBMIT ASSEMBLED PRINTED INSTRUCTIONS FOR THE OPERATION AND MAINTENANCE OF
EACH ITEM INSTALLED ALONG
ALONG WITH EQUIPMENT
EQUIPMENT CUTS
CUTS AND
AND CONTROL
CONTROL WIRING
WIRING DIAGRAMS.
UNION
BFPR
3. CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATION OF ANY EXISTING MINOR
INTERFERENCE'S, INCLUDING CONDUIT,
CONDUIT, HANGERS,
HANGERS, ETC.,
ETC., AT NO ADDITIONAL COST.
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
CHECK VALVE
8. SUBMIT COORDINATED SHOP DRAWINGS FOR REVIEW. THE SHOP DRAWINGS SHALL
INDICATE WORK OF OTHER TRADES AND MUST BE SUBMITTED PRIOR TO FABRICATION AND
INSTALLATION.
BALANCING VALVE
9. SUBMIT EQUIPMENT SPECIFICATIONS FOR REVIEW BEFORE PURCHASE.
HOSE BIBB
HOSE
10. CONTRACTOR SHALL
SHALL GUARANTEE
GUARANTEE ALL
ALL WORK
WORK AND
AND MATERIAL
MATERIAL FOR
FOR ONE
ONE YEAR AFTER
COMPLETION AGAINST
AGAINST ALL
ALL DEFECTS OF MATERIAL, EQUIPMENT AND WORKMANSHIP.
NIKA A+E
WALL HYDRANT
11. PROVIDE COMPETENT OPERATING
OPERATING TECHNICIAN TO INSTRUCT THE OWNER
OWNER IN THE
OPERATION AND MAINTENANCE
MAINTENANCE OF THE INSTALLED EQUIPMENT.
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
BACKFLOW PREVENTER
PRIMER
TRAP PRIMER
12. PROVIDE ACCESS PANELS FOR ALL VALVES OR ANY PIECE OF EQUIPMENT WHEN
NECESSARY TO LOCATE ABOVE NON-ACCESSIBLE CEILINGS. SUBJECT TO THE APPROVAL OF
THE ARCHITECT. NO EQUIPMENT
EQUIPMENT SHALL
SHALL BE
BE LOCATED
LOCATED DIRECTLY
DIRECTLY ABOVE
ABOVE WALLS.
SHOCK ARRESTOR
13. PROVIDE ALL HOLES, SLEEVES AND CAULKING
CAULKING FOR INSTALLATION OF
OF THIS WORK. CAULKING
TO CONFORM
CONFORM TO
TO FIRE
FIRE RATING OF
OF WALLS.
14. PIPING SHALL BE ABOVE CEILING AND CLEAR ANY EXISTING PIPING, LIGHTING FIXTURES,
DUCTS,
DUCTS, ETC.
ETC.
15. RUN NEW WASTE PIPES AS CLOSE AS POSSIBLE TO UNDERSIDE OF FLOOR SLAB AND VENT
PIPING
PIPING AS CLOSE AS POSSIBLE TO SLAB ABOVE.
16. CONTRACTOR SHALL SUBMIT SKETCH TO THE STRUCTURAL ENGINEER FOR APPROVAL,
PRIOR TO MAKING REQUIRED BEAM PENETRATIONS.
17. DISRUPTION OF ANY EXISTING SERVICE SHALL BE COORDINATED WITH THE OWNER AND
SHALL
SHALL BE PERFORMED
PERFORMED AT
AT A TIME AND MANNER
MANNER SO
SO AS TO CAUSE
CAUSE THE
THE OWNER
OWNER A
A MINIMUM OF
INCONVENIENCE.
18. FOR EXACT LOCATION OF PLUMBING FIXTURES, REFER TO ARCHITECTURAL PLANS AND
ELEVATIONS.
19. SIZES AND ROUTING OF EXISTING PIPING ARE BASED ON AS-BUILT DRAWINGS PROVIDES BY
CITY OF GAITHERSBURG. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND SHALL
REPORT CONSISTENCY
CONSISTENCY TO
TO AE
AE PRIOR
PRIOR TO
TO START
START OF
OF WORK.
20. CONTRACTOR SHALL LOCATE NEW SANITARY (2%SLOPE) AND VENT PIPING TO GREASE
INTERCEPTOR TO ENSURE THAT
THAT THE
THE INVERT
INVERT OF
OF EXISTING PIPING (THAT NEED TO BE
CONNECTED)
CONNECTED) ARE
ARE MAINTAINED.
MAINTAINED.
EXAMINATION
EXAMINATION OF
OF EXISTING
EXISTING CONDITIONS:
CONDITIONS:
1. PRIOR TO BID VISIT
VISIT AND
AND CAREFULLY
CAREFULLY EXAMINE
EXAMINE THOSE
THOSE PORTIONS OF THE PRESENT BUILDING
AFFECTED BY THIS WORK SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND
OF THE WORK BEFORE SUBMITTING
DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF
PROPOSALS.
2. SUBMISSION OF A PROPOSAL WILL BE CONSTRUCTED AS EVIDENCE THAT SUCH
EXAMINATION HAS
HAS BEEN
BEEN MADE
MADE AND
AND LATER
LATER CLAIMS
CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS
EXAMINATION
REQUIRED BECAUSE DIFFICULTIES ENCOUNTERED, WHICH COULD, HAVE BEEN FORESEEN HAD
EXAMINATION HAD
HAD BEEN
BEEN MADE,
MADE, WILL
WILL NOT BE RECOGNIZED
SUCH AN EXAMINATION
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
No.
Description
Date
CONNECTION
WORK:
CONNECTION TO
TO EXISTING
EXISTING WORK:
EXISTING WORK TO INSURE MINIMUM
1. PLAN INSTALLATION OF NEW WORK AND CONNECTIONS TO EXISTING
REGULAR OPERATION
OPERATION OF
OF EXISTING
EXISTING FACILITIES.
FACILITIES.
INTERFERENCE WITH REGULAR
2. SUBMIT TO THE OWNER FOR APPROVAL,
APPROVAL, DATE SCHEDULE OF NECESSARY TEMPORARY SHUTSHUT-DOWNS SHALL
SHALL BE
BE MADE AT SUCH
SUCH TIMES
TIMES AS WILL NOT
DOWN OF EXISTING SERVICES. ALL SHUT-DOWNS
OPERATING OF
OF EXISTING
EXISTING FACILITIES
FACILITIES AND ONLY AFTER WRITTEN
INTERFERE WITH REGULAR OPERATING
APPROVAL OF
OF OWNER.
OWNER.
APPROVAL
Revisions
Drawing Title
PLUMBING GENERAL NOTES,
ABBREVIATIONS AND
SYMBOLS
3. TO INSURE CONTINUOUS OPERATION, MAKE NECESSARY TEMPORARY CONNECTIONS BETWEEN
NEW AND EXISTING WORK.
Phase
4. CONNECT NEW WORK TO EXISTING WORK IN A NEAT
NEAT AND APPROVED MANNER. RESTORE
EXISTING
EXISTING WORK DISTURBED
DISTURBED TO
TO ORIGINAL CONDITION.
CONCEPT
A/E Project Number
12-0009.015
Date
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
RP
Checked By
AK
Sheet
1:1
Number
P001
SCALE: 1-1/2"
1-1/2" =
= 1'-0"
1'-0"
SCALE:
2'
1'
0
SCALE: 1"
= 1'-0"
1'-0"
SCALE:
1" =
1'
2'
KITCHEN
KITCHEN
11
P400
P400
1B
1B
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE:
SCALE: 3/4"
3/4" =
= 1'-0"
1'-0"
UP
UP
SCALE: 1/2"
SCALE:
1/2" =
= 1'-0"
1'-0"
UP
UP
SCALE: 1/4"
SCALE:
1/4" =
= 1'-0"
1'-0"
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
UP
UP
SCALE:
SCALE: 3/16"
3/16" =
= 1'-0"
1'-0"
No.
Description
Date
TOILET
TOILET
33
STORAGE
STORAGE
SCALE:
SCALE: 1/8"
1/8" =
= 1'-0"
1'-0"
0
4'
8'
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
1'
3'
11
2'
0 1/2'
LOADINGDOCK
DOCK
LOADING
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
NIKA A+E
44
22
P400
P400
Revisions
CONFERENCE
CONFERENCE
22
Drawing Title
SCOPE OF
OF WORK
WORK
SCOPE
PLUMBING FIRST FLOOR
OVERALL PLAN - DEMOLITION
Phase
32'
CONCEPT
A Project Number
A/E
12-0009.015
SCALE:
SCALE: 1/16"
1/16" =
= 1'-0"
1'-0"
8'
16'
D
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
11
P100
P100
SS
FIRSTFLOOR
FLOOR OVERALL
OVERALL PLAN-PLUMBING
PLAN-PLUMBING DEMOLITION
DEMOLITION
FIRST
3/16"==1'-0"
1'-0"
3/16"
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
W
NN
CADD Plot Scale
Revit Model
Drawn By
RP
Checked By
AK
Sheet
EE
100%
1:1
Number
P100
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
SCALE: 1" = 1'-0"
1'
0 1/2'
LOADING DOCK
DOCK
LOADING
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
11
P401
P401
1B
1B
KITCHEN
KITCHEN
11
3'
DW
DW
NIKA A+E
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
SCALE: 3/4" = 1'-0"
SCALE: 1/2" = 1'-0"
UP
UP
SCALE: 1/4" = 1'-0"
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
UP
UP
SCALE: 3/16" = 1'-0"
No.
TOILET
TOILET
33
Description
Date
Room
Room
15
15
22
P401
P401
16'
0
4'
8'
12'
0
2'
4'
8'
0
1'
2'
4'
0
1'
2'
UP
UP
STORAGE
STORAGE
SCALE: 1/8" = 1'-0"
0
4'
8'
44
CONFERENCE
CONFERENCE
22
Room
Room
Revisions
13
13
Drawing Title
SCOPE OF WORK
PLUMBING FIRST FLOOR
OVERALL PLAN
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
11
P101
P101
FIRST FLOOR
FLOOR OVERALL
OVERALL PLAN-PLUMBING
PLAN-PLUMBING
FIRST
S
S
3/16"
3/16" == 1'-0"
1'-0"
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
W
W
N
N
CADD Plot Scale
Revit Model
Drawn By
RP
Checked By
AK
Sheet
E
E
100%
1:1
Number
P101
SCALE: 1-1/2" = 1'-0"
2'
1'
0
2'
(E) 1/2"
1/2" CW
CW &
& HW
HW
ABOVE THE CEILING
HW
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
(E) 1 1/4"
1/4" CW
CW &
& HW
HW
IN THE CEILING
SCALE: 1" = 1'-0"
0 1/2'
1'
CW
CW
HW
1 1/4"ø
1 1/4"ø
1 1/4"ø
(E) FLOOR DRAIN
TO REMAIN
1 1/2"ø
1/2"ø
3'
1/2"ø
2'
4"ø
SCALE: 3/4" = 1'-0"
1'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
(E) 3"
3" VENT
VENT
UP
4"ø
4"ø
4"ø
4"ø
1/2"ø
1/2"ø
(E) 1/2" CW & HW
IN THE CEILING
4'
0
NIKA A+E
4"ø
SCALE: 1/2" = 1'-0"
1
P400
KITCHEN ENLARGED PLAN-PLUMBING DEMOLITION
3/8" = 1'-0"
SCALE: 1/4" = 1'-0"
0
2'
4'
8'
0
1'
2'
CAP AS REQUESTED
UNDER THE FLOOR
1 1/2"ø
1 1/2"ø
4"ø
LV-(E)
12'
WC-(E)
SCALE: 3/16" = 1'-0"
8'
4'
(E)WASHER/DRYER
TO BE RELOCATED
No.
Description
Date
Revisions
SCALE: 1/8" = 1'-0"
0
4'
8'
16'
0
3/4"ø
3/4"ø
1 1/2"ø
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
2"ø
2"ø
1 1/2"ø
(E)3"
(E)3" VENT
VENT UP
Drawing Title
SCOPE OF WORK
PLUMBING FIRST FLOOR
ENLARGED PLANS DEMOLITION
Phase
32'
CONCEPT
A Project Number
A/E
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
D
Date
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
S
35%
60%
90%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
22
P400
APARTMENT AND
AND BATHROOM
BATHROOM ENLARGED
ENLARGED PLAN-PLUMBING
PLAN-PLUMBING DEMOLITION
DEMOLITION
APARTMENT
W
3/8" = 1'-0"
N
CADD Plot Scale
Revit Model
Drawn By
RP
Checked By
AK
Sheet
E
100%
1:1
Number
P400
2'
SCALE: 1-1/2" = 1'-0"
1'
0
3"ø
3"ø
1%
1%SLOPE
SLOPE
4"ø
4"ø
2'
RE-CONNECT
RE-CONNECT THE
THE
NEW
NEW SINK
SINK WITH
WITH
EXISTING
EXISTINGPIPING.
PIPING.
3'
3"ø
3"ø
CO
CO
CO
CO
3/4"ø
3/4"ø
2"ø
2"ø
CW
CW
NIKA A+E
2"ø
2"ø
2"ø
2"ø
FD-1
FD-1
2"ø
2"ø
SCALE:
SCALE:3/4"
3/4"=
=1'-0"
1'-0"
4"ø
4"ø
(E)
(E) CW
CW && HW
HW IN
IN
THE
CEILING
THE CEILING
4"ø
4"ø
2"ø
2"ø
KS-1
KS-1
111/2"ø
1/2"ø
CO
CO
FS-1
FS-1
SS-1
2"ø
2"ø
CO
CO
CW
CW
3/4"ø
3/4"ø
CW
CW
HW
HW
SS-1
DW
DW
111/2"ø
1/2"ø
4'
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
4"ø
4"ø
CW
CW
CW
CW
3/4"ø
3/4"ø
CW
CW
HW
HW
HW
HW
DRAIN
DRAINPIPE
PIPEABOVE
ABOVETHE
THEFLOOR.
FLOOR.
REFER
TO
RISE
DIAGRAM
REFER TO RISE DIAGRAM
REUSE
EXISTING
CW
&&
HW
REUSE
EXISTING
CW
HW
TO
SERVE
THE
NEW
THREE
TO
SERVE
THE
NEW
THREE
COMPARTMENT
SINK
COMPARTMENT
SINK
SCALE:
SCALE:1/2"
1/2"=
=1'-0"
1'-0"
FD-(E)
FD-(E)
4"ø
4"ø
2'
1'
EMERGENCY
EMERGENCYFLOOR
FLOOR
DRAIN.
DRAIN.VERIFY
VERIFYEXACT
EXACT
LOCATION
LOCATIONIN
INFIELD
FIELD
3"ø
3"ø
3/4"ø
3/4"ø
0
CO
CO
4"ø
4"ø
3"ø
3"ø
(E)
(E) 3"
3" VENT
VENT PIPE
PIPE
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
4"ø
4"ø
1%
1%SLOPE
SLOPE
ICE
ICE
MAKER
MAKER
CW
CW
3/4"
DRAIN SERVES
3/4" DRAIN
SERVES THE
THE ICE-MAKER.
ICE-MAKER.
All
All CONNECTIONS
CONNECTIONS TO
TO THE
THE MACHINE
MACHINE
WILL
BE PROVIDED
PROVIDED BY
WILL BE
BY OTHERS
OTHERS
FD-1
FD-1
11 1/4"ø
1/4"ø
1/2" COLD WATER LINE TO THE
THE ICEICEMAKER. All CONNECTIONS
CONNECTIONS TO
TO THE
THE
MACHINE
MACHINE WILL
WILL BE PROVIDED BY OTHERS
OTHERS
1% SLOPE
SLOPE
1%
1% SLOPE
SLOPE
1%
SCALE:
SCALE: 1"
1" =
= 1'-0"
1'-0"
1'
0 1/2'
11 1/4"ø
1/4"ø
11 1/4"ø
1/4"ø
HS-1
HS-1
CW
CW
HW
HW
PROVIDE
PROVIDEFLOW
FLOWCONTROL
CONTROLWITH
WITHAIR
AIR
INTAKE.
INTAKE.REFER
REFERTO
TODETAILS
DETAILS
4"ø
4"ø
CW
CW
HW
HW
DRAIN FOR
FOR ICEMAKER
ICEMAKER
2'
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
CO
CO
CAP
CAP
1'
CO
CO
CO
CO
1%
1%SLOPE
SLOPE
(E) 1 1/2" CW & HW
HW
IN THE
THE CEILING
CEILING
0
GI-1
GI-1
CO
CO
(E)
(E) 1/2"
1/2" CW
CW &
& HW
HW
IN
IN THE
THECEILING
CEILING
DW-1
DW-1
HIGH
HIGHTEMPERATURE
TEMPERATUREDISHWASHER
DISHWASHER
WITH
WITHBUILT-IN
BUILT-INBOOSTER
BOOSTERHEATER
HEATER
2"
2"DRAIN
DRAINPIPE
PIPEFROM
FROM
DISHWASHER
DISHWASHER
33COMPARTMENT
COMPARTMENTKITCHEN
KITCHENSINK
SINKKS-1
KS-1
DISCHARGED
DISCHARGEDTHROUGH
THROUGHINDIRECT
INDIRECTDRAIN
DRAININ
INFS-1
FS-1
11
P401
P401
KITCHEN ENLARGED
KITCHEN
ENLARGED PLAN-PLUMBING
PLAN-PLUMBING
3/8"
3/8" =
= 1'-0"
1'-0"
2" OPEN SITE DRAIN
8'
BWV-1
1/2"ø
1/2"ø
(E)3"
(E)3" VENT
VENTUP
UP
4"ø
4"ø
SCALE:
SCALE:1/4"
1/4"==1'-0"
1'-0"
HW
1/2"ø
CW
CW
HW
2 " PIPE BELOW SLAB
PIPES ABOVE CEILING
2" OPEN
SITE DRAIN
HW
CW
CW
4"ø
4"ø
2"ø
2"ø
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
LV-1
LV-1
WC-1
WC-1
4"ø
4"ø
CAP
CAPPIPING
PIPINGBACK
BACK
TO
TOTHE
THEWALL
WALL
(E)
(E)FD
FD
2 " PIPE BELOW SLAB
WASHER & DRYER
HW
HW
CW
CW
221/2"ø
1/2"ø
1/2" PIPES ABOVE
CEILING
RE-CONNECT
RE-CONNECTNEW
NEW
FIXTURES
FIXTURESWITH
WITH
EXISTING
EXISTINGPIPES
PIPES
WASHER & DRYER
3
3
P501
P501
VB-1
SCALE:
SCALE:3/16"
3/16"==1'-0"
1'-0"
2"ø
2"ø
HW
HW
CW
CW
1/% SLOPE
1/2"ø
12'
8'
4'
1/2"ø
1/2"ø
2"ø
BWV-1
(E)
(E) BELOW
BELOW FLOOR
FLOOR
111/4"ø
1/4"ø
1 1/4"ø
1 1/4"ø
CO
CO
1 1/4"ø
1 1/4"ø
1 1/4"ø
1 1/4"ø
CD
CD
No.
CO
CO
1 1/4"ø
1 1/4"ø
1 1/4"ø
1 1/4"ø
16'
0
VB-1
1/% SLOPE
HW
CW
0
2'
4'
2 " PIPE ABOVE GROUND
1 1/4"ø
1 1/4"ø
Description
Date
PROVIDE DIRECT
PROVIDE DIRECT
CONNECTION TO THE
CONNECTION TO THE
CEILING CASSETTE.
CEILING CASSETTE.
REFER TO MECH DWG
REFER TO MECH DWG
FOR CONTINUATION.
FOR CONTINUATION.
(TYPE OF 5)
(TYPE OF 5)
SCALE:
SCALE:1/8"
1/8"==1'-0"
1'-0"
Revisions
CONDENSATE DRAIN
CONDENSATE DRAIN
DISCHARGE ABOVE GROUND.
DISCHARGE ABOVE GROUND.
CD
CD
CD
CD
ROUTE CONDENSATE
ROUTE CONDENSATE
DRAIN PIPE ABOVE
DRAIN PIPE ABOVE
CEILING AND UNDER
CEILING AND UNDER
ALL DUCTWORKS
ALL DUCTWORKS
ROUTE CONDENSATE
ROUTE CONDENSATE
DRAIN PIPE ABOVE
DRAIN PIPE ABOVE
CEILING AND UNDER
CEILING AND UNDER
ALL DUCTWORKS
ALL DUCTWORKS
1 1/4"ø
1 1/4"ø
SCOPE
SCOPEOF
OFWORK
WORK
Drawing Title
PLUMBING FIRST FLOOR
ENLARGED PLANS
CONDENSATE DRAIN
CONDENSATE DRAIN
DISCHARGE ABOVE GROUND.
DISCHARGE ABOVE GROUND.
Phase
CONCEPT
32'
0
4'
8'
CD
CD
A/E Project Number
SCALE:
SCALE:1/16"
1/16"==1'-0"
1'-0"
8'
16'
12-0009.015
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
3"
3"VENT
VENTDISCHARGET
DISCHARGETOUTSIDE
OUTSIDEABOVE
ABOVE
GROUND.
GROUND.REFER
REFERTO
TORISER
RISERDIAGRAM
DIAGRAM
Date
2
2
P401
P401
APARTMENT AND
BATHROOM
ENLARGED
PLAN-PLUMBING
APARTMENT
AND
BATHROOM
ENLARGED
PLAN-PLUMBING
3/8" = 1'-0"
3/8" = 1'-0"
S
S
E
E
W
W
N
N
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
RP
Checked By
AK
Sheet
1:1
Number
P401
PLUMBING
SCHEDULE
PLUMBING FIXTURES
FIXTURES SCHEDULE
KITCHEN SINK
SERVICE SIZE (INCHES)
BOWL SIZE (INCH)
WIDTH
SCALE: 1-1/2" = 1'-0"
0
1'
18
# OF 70% OF VOLUME
LENGTH HEIGHT BOWL
(CU INCH)
18
14
2'
6,350
FIXTURE TYPE
WC-1
WATER CLOSET
LV-1
LAVATORY
KS-1
28
MOP SINK
3" FLOOR DRAIN
1
3
3 DFU
2
6
12 DFU
1
3 DFU
3
TOTAL GPM PER
UPC
UPC TABLE 10-2
SCALE: 1" = 1'-0"
1'
0 1/2'
2
VOLUME
(GPM)
FIXTURE
TAG
PLUMBING FIXTURE QUANTITY DRANAGE FIXTURE UNITS TOTAL
(DFU) PER UPC TABLE 7-3
COMMERCIAL SINK
WITH GRINDER
18 GPM
BASED ON THE SPECIFIED DISHWASHER CAPACITY
3 GPM
GREASE INTERCEPTOR
INTERCEPTOR CAPACITY
PER IPC TABLE 1003.3.4.1, GREASE RETENTION
CAPACITY
49 GPM
100 LB
WASTE
VENT CW
SF
11' - 7 1/2"
REMARKS
HW
4
2
1
-
1 1/2
1 1/2
1/2
1/2
AMERICAN STANDARD MALL MOUNTED
KITCHEN SINK
2
1 1/2
1/2
1/2
T&S BRASS WALL MOUNTED
MOUNTED
SS WITH THREE BOWLS AND LEFT DRAINBOARD. AERO MODEL F3L SERIES WITH T&S
FAUCET MODEL # B-0230 OR EQUAL
SS-1
SERVICE SINK
2
1 1/2
1/2
1/2
MOUNTED AMERICAN STANDARD
STANDARD FAUCET PROVIDED WITH VACUUM BREAKER, HOSE
LIGHT COMMERCIAL WALL MOUNTED WITH WALL MOUNTED
THREADS, AND BUCKET HOOK SPOUT.
HS-1
HAND SINK
1 1/2
1 1/2
1/2
1/2
WITH FAUCET.
FAUCET. ADVANCE
ADVANCE TACO MODEL 7-PS-67 OR SMALLER
SMALL SIZE BOWL WITH
FS-1
FLOOR SINK
2
1 1/2
-
-
WITH DOME STRAINER, FULL
FULL GATE
GATE AND
AND SEDIMENT
SEDIMENT BUCKET
BUCKET OR EQUAL
LIGHT COMMERCIAL MODEL # 2370 WITH
FD-1
FLOOR DRAIN
3
2
-
-
WITH BALL
BALL FLOAT
FLOAT TYPE
TYPE BACKWATER
BACKWATER VALVE
VALVE AND INTERNAL CLEANOUTS OR EQUAL
URN MODEL # Z742 WITH
GI-1
GREASE INTERCEPTOR
3
2
-
-
WITH EXTENSION, PC/FG # 8250 OR EQUAL
JAY R SMITH 8200 SERIES WITH
AMERICAN STANDARD FLOOR MOUNTED ADA COMPLIENT
VB-1
VALVE BOX
2
1 1/2
1/2
1/2
BWV-1
BACK WATER VALVE
2
-
-
-
DW-1
DISHWASHER
2
1 1/2
-
3/4
SLOPE 1/%
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
KK
1'-6"
PROVIDE2'
MIN.
- 0"
DISTANCE FROM
THE GROUND
RECESSED INTO THE WALL, OATEY MODEL WITH TWO PORTS DESIGNED TO ACCOMMODATE ADDITIONAL DRAIN LINES. OR EQUAL
FLAPPER, MIA MODEL B 1000 OR EQUAL
CAST IRON BODY WITH PVC FLAPPER,
HIGH TEMPERATURE
TEMPERATURE SINGLE
SINGLE RACK,
RACK, CMA-180CB (CORNER LOCATION),
LOCATION), ENERGY STAR QUALIFIED. WITH BOOSTER HEATER . ELECTRIC
RATING: 3 PHASE, 208 VOLTS AND 45 AMPS OR EQUAL.
33
3'
P501
TAG
DESCRIPTION
SCALE: 3/4" = 1'-0"
CAPACITY
CONDENSATE PIPE
DISCHARGE
CONDENSATE
PIPE DISCHARGE
3/8" = 1'-0"
NIKA A+E
BASIS OF DESIGN MANUFACTURER AND MODEL
BFP-1
BACKFLOW PREVENTER
1/2"
5 PM @ 11PSI
REDUCED PRESSURE
PRESSURE ZONE ASSEMBLE
ASSEMBLE MODEL
MODEL WATTS SERIES 009 OR ECUAL.
ECU
BFP-2
BACKFLOW PREVENTER
3/4"
13 PM@ 12PSI
REDUCED PRESSURE
PRESSURE ZONE ASSEMBLE
ASSEMBLE MODEL
MODEL WATTS SERIES 009 OR ECUAL.
ECU
2'
1'
0
SIZE
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
FIRST FLOOR
FLOOR
FIRST
0' - 0"
BLACKFLOW
BLACKFLOW PREVENTER
PREVENTER SCHEDULE
SCHEDULE
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
1 1/4"ø
1 1/4"ø
HW C
W
4"ø VENT
3/4"ø
1 1/2"ø
THE ROOF C
W
BWV-1
HW
3/4"ø
2"ø
SCALE: 1/4" = 1'-0"
HW
C
3/4"øW
CW
1/2"ø 1 1/2"ø
CW
HW
1 1/2"ø
1/2"ø 2"ø
1 1/2"ø
1"ø
1"ø
HW
2"ø
HW
1/2"ø
CW
HW
CW
CW
HW
3/4"ø
2"ø
3/4"ø
1"ø
1"ø
3/4"ø
SCALE: 3/16" = 1'-0"
1"ø
1"ø
4"ø
1/2"ø
HW
HS-1
3/4"ø
HW
3/4"ø
CW
KS-1
FD-1
3"ø
CO
1 1/2"ø
LV-1
1/2"ø
CAP PIPING BACK TO
THE WALL
1/2"ø
(E) SAN PIPE
4"ø SLAB
UNDER
(E) FD TO REMAIN
4"ø
4"ø
CAP PIPING BACK TO THE WALL
CO
HW
CW
(E)
EMERGENCY
BFP-2
FLOOR DRAIN
2"ø
1 1/2"ø
(E) FD TO REMAIN
CO2"ø
16'
FS-1
2"ø
DW-1
CW 4"ø
4"ø
4"ø
3/4"ø
4"ø
SCALE: 1/8" = 1'-0"
8'
4'
0
4"ø
GI-1
UNDERGROUND
CO
PROVIDE FLOW
CONTROL WITH AIR
4"ø
INTAKE. REFER TO PLAN
& DETAILS
3/4"ø
4"ø 4"ø
3/4"ø
2"ø
SS-1
PROVIDE FLOW
CONTROL WITH AIR
INTAKE. REFER TO PLAN
& DETAILS
Revisions
Drawing Title
PLUMBING RISER DIAGRAMS
AND SCHEDULE
4"ø
2"ø
Phase
32'
CONCEPT
A/E Project Number
12-0009.015
SCALE: 1/16" = 1'-0"
8'
16'
Date
1
P501
RISER DIAGRAM-APARTMENT
PLUMBING
RISER DIAGRAM-APARTMENT
NEW WORKNEW WORK
1 PLUMBING
P501
22
PLUMBING
PLUMBING RISER
RISER DIAGRAM-KITCHEN
DIAGRAM-KITCHEN NEW
NEW WORK
WORK
Date
CO
4"ø
CO
4"ø
4"ø
UNDERGROUND
SS-1
3/4"ø
4"ø
4"ø
CO
Description
CO
3/4"ø
4"ø
DW-1
No.
CO
4"ø
BFP-2
2"ø
GI-1
2"ø
CO
CO
2 1/2"ø
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
4"ø
HW
4"ø
2"ø
4"ø
3/4"ø
3/4"ø
2"ø
4"ø
CAP PIPING BACK TO THE FLOORCAP PIPING BACK TO THE FLOOR
4"ø
2 1/2"ø
3"ø
3"ø
FS-1
4"ø
CO
3/4"ø
FD-1
3/4"ø
3/4"ø
2"ø
CO
(E) EMERGENCY
FLOOR DRAIN
FD-1
4"ø
WC-1
(E) SAN PIPE
UNDER SLAB
3"ø
3/4"ø
HW
3/4"ø
1 1/2"ø
FD-1
CO
1 1/2"ø
4"ø
4"ø
CW
CW
KS-1
1"ø
1/2"ø
4"ø
1/2"ø
3/4"ø
3/4"ø
1"ø
CW
CW
12'
0
4'
8'
2"ø
3" VENT DISCHARGET
OUTSIDE ABOVE GROUND.
REFER TO RISER DIAGRAM
HS-1
1"ø
CW
1/2"ø
3" VENT DISCHARGET
OUTSIDE ABOVE GROUND.
REFER TO RISER DIAGRAM
1"ø
2"ø
4"ø
PROVIDE WATER HAMMER
ARRESTOR TYP "A"
PROVIDE WATER
C HAMMER
ARRESTOR TYPW"A"
HW
CW
4"ø
1/2"ø
1/2"ø
WASHER/DRYER
1"ø
1"ø
1/2"ø
CW
HW
3/4"ø
CW
CW
HW
CW
1/2"ø
PROVIDE VB-1 and
BWV-1. REFER TO PLAN
FOR LOCATION
2"ø
ICE
MAKER
3/4"ø C
W
HW
HW
8'
4'
2'
CW
1/2"ø
WASHER/DRYER
0
4" VENT PIPE
CONTINUES TO
THE ROOF
1/2"ø
1/2"ø
ICE
MAKER
HW
2"ø
4" VENTH PIPE
W
CONTINUES TO1 1/2"ø
CW
CW
CW
HW
BFP-1
1 1/4"ø
HW
CW
1/2"ø
2"ø
HW
1 1/2"ø
HW CW
1/2"ø
CW
CW
1/2"ø
1/2"ø
1 1/4"ø
1/2"ø
PROVIDE VB-1.
PROVIDE
REFERHAMMER
TO PLAN
ARRESTOR
TYP "A"
FOR LOCATION
CW
CW
PROVIDE HAMMER
ARRESTOR TYP "A"
1 1/4"ø
1 1/4"ø
HW CW
1 1/4"ø
1/2"ø
1 1/4"ø
HW C
W BFP-1
CW
CW
SCALE: 1/2" = 1'-0"
0
1'
2'
4'
4"ø VENT
CW
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
2'
GREASE
CALCULATIONS
GREASE INTERCEPTOR
INTERCEPTOR CALCULATIONS
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
RP
Checked By
AK
1:1
P501
Sheet
Number
P501
2'
FLOOR CLEANOUT
CLEANOUT UNIT
FLOOR
CLEANOUT
CLEANOUT COVER
CSK SCREW
CLEANOUT
CLEANOUT PLUG
PLUG
SCALE: 1-1/2" = 1'-0"
2"
2"
6"
6"
SCALE: 1" = 1'-0"
CLAMP PAN
CLAMP
PAN TIGHTLY
TIGHTLY
INTO
DRAIN COLLAR
INTO DRAIN
COLLAR
DRAIN
DRAIN BODY
BODY
POURED
POURED IN
IN PLACE
PLACE
FLOOR CLEAN OUT DETAIL
FLOOR DRAIN DETAIL
2
NTS
P601
P601
INSULATION (VAPOR
BARRIER
BARRIER TYPE
TYPE IS
IS
REQUIRED
REQUIRED FOR
FOR LOW
LOW
TEMPERATURE
TEMPERATURE PIPE)
PIPE)
4
NTS
P601
DEEP FLOOR PENETRATION CLEAN OUT DETAIL
NTS
SCALE: 3/4" = 1'-0"
PROVIDE HIGH
COMPRESSIVE
STRENGTH INSULATION
INSULATION
UNDER
UNDER INSULATION
SHIELD
SHIELD
WELD
INSULATION
INSULATION SHIELD
SHIELD
AT
AT HANGER
SADDLE
ADJUSTABLE CLEVIS HANGER
SEE SPECIFICATIONS
SPECIFICATIONS FOR
FOR MAX.
MAX.
SUPPORT SPACING)
A
FIXTURE UNIT
RATING
CONCEAL
CONCEAL IN CEILING
SPACE TO
TO ELIMINATE
ELIMINATE
ACCESS PANELS
1-11
B
C
12-32
33-60
D
61-113
E
F
114-154
155-330
FINISHED WALL
BACK-SPLASH
CARRIER
STAINLESS
STAINLESS STEEL
BELLOWS UNDER
NORMAL
NORMAL CONDITIONS
WATER HAMMER
ARRESTOR
PDI SYMBOL
SUPPLY RISER
BEARING PLATE
PDI "A"
BALL VALVE
LAVATORY
12"
BAND
1-5/8" 12 GAUGE
GAUGE
CHANNEL
CHANNEL OR
OR 2"x2"x1/4"
2"x2"x1/4"
ANGLE
1" MAX.
PDI SYMBOL
451 HUNGERFORD DRIVE (P)301.770.3520
4TH FLOOR
(F)301.770.3521
ROCKVILLE, MD 20850
www.nika-ae.com
BELLOWS EXPANDED
UNDER SHOCK
PRESSURE
ADJUSTABLE
ADJUSTABLE CLEVIS HANGER
HANGER
SEE SPECIFICATIONS
SPECIFICATIONS FOR
FOR MAX.
MAX.
SUPPORT SPACING)
SPACING)
PROVIDE INSULATION
SHIELD & INSERT FOR
FOR
ALL
ALL PIPING
PIPING (8"
(8" MIN.)
MIN.)
SCALE: 1/2" = 1'-0"
PDI (PLUMBING AND
DRAINAGE INSTITUTE
WATER HAMMER
ARRESTER
STAINLESS
STAINLESS STEEL
STEEL
CASING
1/2" DIA. HANGER
RODS WITH
36" MAX. SPACING
ON EACH CHANNEL
NOTES:
NOTES:
SEE SPECIFIER FOR
DETAILED
HANGER REQUIREMENTS
REQUIREMENTS
NIKA A+E
WATER
WATER HAMMER
HAMMER ARRESTOR
ARRESTOR SCHEDULE
SCHEDULE
1/2" CW & HW SUPPLIES
WITH STOP. INSULATE CW &
HW SUPPLIES.
TYPICAL BRANCH LINE
NOTES:
1. INSTALLATION OF WATER HAMMER
ARRESTORS SHALL BE AT THE END OF BRANCH
ARRESTORS
LINE BETWEEN THE LAST TWO FIXTURES
SERVED.
SUPPLY WATER
PIPING
1 1/2"
1/2" WASTE
WASTE & "P"
"P" TRAP
TRAP
INSULATED
MAXIMUM
MAXIMUM PIPE/TUBING
PIPE/TUBING SUPPORT
SUPPORT BRACING
BRACING
SCALE: 1/4" = 1'-0"
THRU
THRU 3/4
3/4
11
11 1/4
1/4 1 1/2
PIPE FT.
FT.
7
77
77
TUBING
TUBING FT.
FT.
5
66
77
22
2 1/2
3
44
55
66
8
99
10
10
11
11
12
14
14
16
16
17
19
88
88
99
10
12
12
13
13
14
16
PIPEING HANGER DETAIL
WATER HAMMER ARRESTER DETAIL
6
NTS
P601
7
NTS
P601
VENT PIPE
PIPE DISCHARGE
DISCHARGE IN EXTERIOR
BIRD PROTECTION
PROTECTION AT
WALL. PROVIDE BIRD
THE OUTSIDE TERMINATION
SCALE: 3/16" = 1'-0"
FINISHED FLOOR
3. THE SUM OF
OF FIXTURE
FIXTURE UNIT RATING OF UNITS
OVER 20' IN LENGTH SHALL BE EQUAL TO OR
GREATER THAN THE
THE DEMAND OF THE
THE BRANCHES.
NOTE:
NOTE: FOR
FOR TRAPEZE
TRAPEZE HANGER
HANGER TAKE
TAKE SPACING
SPACINGOF
OF SMALLEST
SMALLEST SIZE
SIZE ON TRAPEZE.
TRAPEZE.
5
BLOCK BASE PLATES
2. ONE WATER HAMMER ARRESTOR
ARRESTOR PER 20' LINE,
AND ANOTHER
ANOTHER FOR
FOR BRANCHES
BRANCHES OVER 20' IN
LENGTH.
12'
8'
4'
0
WALL SUPPORT PIPING DETAIL
3
NTS
VENT
VENT PIPE
PIPE CONNECTED
AT EXISTING.
EXISTING. REFER TO
THE
THE PLAN
PLAN PIPING
PIPING LAYOUT.
LAYOUT.
TYPICAL LAVATORY (HS-1) CARRIER DETAIL
NTS
Professional Certification.
I hereby certify that these
documents were prepared or
approved by me, and that I am a
duly licensed professional
engineer under the laws of the
State of Maryland. License
number 24152,
Expiration date 03.19.2017
No.
Description
Date
NON-SKID COVER
3" GREESE
INTERCEPTOR
VENT
16'
2" FLOW
CONTROL VENT
SCALE: 1/8" = 1'-0"
8'
4'
FRONT VIEW
SIDE VIEW
HANGER
HANGER ROD
P601
P601
0
UNISTRUT CHANNEL
WITH PIPE CLIPS
EXPANSION SHIELD
(MINIMUM)
1'
0
2'
1'
1
P601
P601
2'
1'
0
CONCRETE
CONCRETE
FLOOR
SLAB
FLOOR SLAB
CASEY
COMMUNITY
CENTER INTERIOR
RENOVATION
810 S FREDERICK AVE,
GAITHERSBURG, MD 20877
3'
0 1/2'
FLOW
FLOW
4'
2'
1'
0
CONCRETE SLAB
PIPE WITH
PROTECTIVE COATING
LEAD
LEAD AND
AND OAKUM
OAKUM OR
OR
NEOPRENE
NEOPRENE GASKET
GASKET
8'
4'
2'
0
WATER PROOF
PROOF
WATER
MEMBRANE
MEMBRANE
SLOPE
DRAIN
SLOPE TO
TO DRAIN
CAULKING
CAULKING FERRULE
FERRULE
NOM.
NOM. SIZE
SIZE IN.
IN.
4" MIN.
MIN. SPECIFY
SPECIFY
EXTENSION
HEIGHT
REQUIRED
CLEAN-OUT
KS-1
Revisions
LOCK AND LIFT RING
Drawing Title
4" NO-HUB OUTLET
PLUMBING DETAILS
4" NO-HUB
NO-HUB INLET
INLET
32'
AIR RELIEF
RELIEF
CO
1% SLOPE
REMOVEABLE
BAFLERS
8
P601
P601
GREASE INTERCEPTOR DETAIL
NTS
FLOW CONTROL
WITH INTAKE AIR
1% SLOPE
STATIC
STATIC WATER
WATER LINE
LINE
SCALE: 1/16" = 1'-0"
16'
TOPPING
CERAMIC
CERAMIC TILE
TILE
AND SETTING
BED
AND
SETTING BED
FINISHED
FINISHED FLOOR
FLOOR
SURFACE
SURFACE
SIDE VIEW TRAPEZE HANGER FOR UP TO 1000 LB. UNIFORM LOAD
8'
STAINLESS
STEEL MESH
PIPE WITH INSULATION
FLOOR
FLOOR DRAIN
DRAIN STRAINER
STRAINER
FINISHED
FINISHED FLOOR
FLOOR
0
IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED
CONCRETE SURFACE
OR FLOOR COVERING
AS REQUIRED
FS-1
9
P601
Phase
CO
CONCEPT
4"
PROVIDE EXTENSION
FLOOR
TO RICH THE FLOOR
ELEVATION. MIN 4"
ELEVATION.
ALWAYS REQUIRED
A/E Project Number
4"
GI-1
KITCHEN SINK (KS-1) DRAIN PIPE CONNECTIONS DIAGRAM
NTS
CO
12-0009.015
Date
DISCHARGES AT
EXISTING SANITARY
LINE UNDER SLAB
35%
60%
90%
100%
Drawing Scale: AS NOTED
CADD Filename
07-15-15
CADD Plot Scale
Revit Model
Drawn By
RP
Checked By
AK
Sheet
1:1
Number
P601
Download