City of Gaithersburg 31 South Summit Avenue, Gaithersburg, Maryland 20877 REQUEST FOR BIDS No. 2016-008 CASEY COMMUNITY CENTER INTERIOR RENOVATIONS EXHIBIT A DRAWINGS MAYOR Jud Ashman COUNCIL MEMBERS Cathy Drzyzgula Henry Marraffa, Jr. Michael Sesma Neil Harris Ryan Spiegel CITY MANAGER Tony Tomasello SCALE: 1-1/2" = 1'-0" 2' 1' 0 100% SUBMITTAL 0 SCALE: 1/2" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 3/16" = 1'-0" SCALE: 1/8" = 1'-0" SCALE: 1/16" = 1'-0" 8' 16' 32' 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' SCALE: 3/4" = 1'-0" 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1' 3' SCALE: 1" = 1'-0" 2' 1' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 2' 0 1/2' CITY OF GAITHERSBURG - CASEY COMMUNITY CENTER 810 S FREDERICK AVE, GAITHERSBURG, MARYLAND 20877 CASEY COMMUNITY CENTER INTERIOR RENOVATION NIKA A+E 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED PROPOSED DESIGN DRAWINGS SHEET LIST SHEET NUMBER A001 A002 A003 A100 A101 A102 A103 A200 A201 A300 A400 A401 A402 A403 A405 A406 A407 A600 A601 E001 E101 E102 E103 E501 EDL101 EDL102 EDP101 EL101 EL102 EL501 EL601 EP101 EP501 EP601 M001 M100 M101 M400 M401 M402 M501 M601 P001 P100 P101 P400 P401 P501 P601 SHEET NAME COVER SHEET GENERAL NOTES, ABBREVIATIONS & SYMBOLS LIST OF REQUIRED SUBMITTALS FIRST FLOOR OVERALL PLAN SECOND FLOOR OVERALL PLAN ROOF OVERALL PLAN SITE PLAN FIRST FLOOR ELEVATION KITCHEN FIRST FLOOR ELEVATION CONFERENCE ROOM AND ENTRIES ROOM SECTIONS AND DETAILS FIRST FLOOR ENLARGED PLANS - DEMOLITION FIRST FLOOR ENLARGED PLANS FIRST FLOOR ENLARGED REFLECTED CEILING PLANS SECOND FLOOR ENLARGED PLAN - COMPUTER ROOM F - DEMOLITION AND NEW WORK SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - ROOM F SECOND FLOOR ENLARGED REFLECTED CEILING PLAN -TEEN ROOM E SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - DANCE STUDIO FIRST FLOOR FINISH SCHEDULE SECOND FLOOR FINISH SCHEDULE ELECTRICAL NOTES AND SYMBOLS ELECTRICAL SITE PLAN ELECTRICAL FIRST FLOOR OVERALL PLAN ELECTRICAL SECOND FLOOR OVERALL PLAN ELECTRICAL DETAILS ELECTRICAL FIRST FLOOR ENLARGED REFLECTED CEILING PLAN - DEMOLITION ELECTRICAL SECOND FLOOR ENLARGED RCP - COMPUTER ROOM F - DEMOLITION ELECTRICAL FIRST FLOOR ENLARGED PLANS - DEMOLITION ELECTRICAL FIRST FLOOR ENLARGED REFLECTED CEILING PLAN ELECTRICAL SECOND FLOOR ENLARGED RCP - COMPUTER ROOM F ELECTRICAL LUMINARE SCHEDULE ELECTRICAL LIGHTING CALCULATIONS - SITE ELECTRICAL FIRST FLOOR ENLARGED PLANS ELECTRICAL RISER DIAGRAM ELECTRICAL PANEL SCHEDULES MECHANICAL NOTES AND SYMBOLS MECHANICAL FIRST FLOOR OVERALL PLAN MECHANICAL SECOND FLOOR OVERALL PLAN MECHANICAL FIRST FLOOR ENLARGED PLANS - DEMOLITION MECHANICAL FIRST FLOOR ENLARGED PLAN MECHANICAL SECOND FLOOR ENLARGED PLAN MECHANICAL DETAILS MECHANICAL SCHEDULES PLUMBING GENERAL NOTES, ABBREVIATIONS AND SYMBOLS PLUMBING FIRST FLOOR OVERALL PLAN - DEMOLITION PLUMBING FIRST FLOOR OVERALL PLAN PLUMBING FIRST FLOOR ENLARGED PLANS - DEMOLITION PLUMBING FIRST FLOOR ENLARGED PLANS PLUMBING RISER DIAGRAMS AND SCHEDULE PLUMBING DETAILS BUILDING FOOTPRINT AND AREAS OF WORK Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 FLOOR 1: KITCHEN AND LOADING DOCK SOUTH ENTRY No. FLOOR 1: ROOM A FLOOR 2: DANCE STUDIO Description Date FLOOR 1: ROOM B+C FLOOR 2: TEEN ROOM ENTRANCE NORTH ENTRY Revisions FLOOR 1: STORAGE AND CONFERENCE FLOOR 2: ROOM F Drawing Title COVER SHEET Phase CONCEPT A/E Project Number 12-0009.015 Date 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 1:1 Number A001 SCALE: 1-1/2" = 1'-0" @ @ C C Ø Ø P P ## A 1' 1' 0 0 1/2' SCALE: 1" = 1'-0" SCALE: 3/4" = 1'-0" C SCALE: 1/2" = 1'-0" 2' 2' 1' 1' 0 0 SCALE: 1/4" = 1'-0" 8' 8' 4' 4' 2' 2' 0 0 D SCALE: 3/16" = 1'-0" 12' 12' 8' 8' 4' 4' 0 0 SCALE: 1/8" = 1'-0" SCALE: 1/16" = 1'-0" ABV ABV A/C A/C AC AC ACOUST ACOUST ADJ ADJ AFF AFF AHU AHU ALT ALT ALUM ALUM ANC ANC ANOD ANOD APPROX APPROX ARCH ARCH ASPH ASPH ASTM ASTM ATTCH ATTCH AUTO AUTO AUX AUX ABOVE ABOVE AIR CONDITIONING CONDITIONING AIR ASPHALT CONCRETE CONCRETE ASPHALT ACOUSTICAL ACOUSTICAL ADJUSTABLE/ADJACENT ADJUSTABLE/ADJACENT ABOVE FINISHED FINISHED FLOOR FLOOR ABOVE AIR AIR HANDLING HANDLING UNIT UNIT ALTERNATE ALTERNATE ALUMINUM ALUMINUM ANCHOR ANCHOR ANODIZED ANODIZED APPROXIMATE APPROXIMATE ARCHITECTURAL ARCHITECTURAL ASPHALT ASPHALT AMERICAN AMERICANSOCIETY SOCIETY FOR FOR TESTING TESTING AND AND MATERIALS MATERIALS ATTACHMENT ATTACHMENT AUTOMATIC AUTOMATIC AUXILIARY AUXILIARY B B BB BB BC BC BD BD BF BF BL BL BLDG BLDG BLKG BLKG BLKHD BLKHD BM BM BO BO BOT BOT BP BP BS BS BSMT BSMT BTWN BTWN BUR BUR BASE BASE BASE BID BID BASE BRICK COURSE COURSE BRICK BOARD BOARD BROOM FINISH FINISH BROOM BUILDING LINE LINE BUILDING BUILDING BUILDING BLOCKING BLOCKING BULKHEAD BULKHEAD BEAM/BENCHMARK BEAM/BENCHMARK BY OTHERS/BOTTOM OTHERS/BOTTOM OF OF BY BOTTOM BOTTOM BEARING PLATE PLATE BEARING BOTH SIDES SIDES BOTH BASEMENT BASEMENT BETWEEN BETWEEN BUILT-UP ROOF ROOF BUILT-UP C C CAB CAB CAP CAP CAT CAT CB CB CCTV CCTV CEM CEM CF CF CFCI CFCI CONDUIT CONDUIT CABINET CABINET CAPACITY CAPACITY CATALOG CATALOG CIRCUIT CIRCUIT BREAKER/CATCH BREAKER/CATCH BASIN BASIN CLOSED CIRCUIT CIRCUIT TELEVISION TELEVISION CLOSED CEMENT/CEMENTITIOUS CEMENT/CEMENTITIOUS CUBIC FEET FEET CUBIC CONTRACTOR-FURNISHED, CONTRACTOR-FURNISHED, CONTRACTOR-INSTALLED CONTRACTOR-INSTALLED CEILING HEIGHT HEIGHT CEILING CAST IRON IRON CAST CIRCLE CIRCLE CIRCUMFERENCE CIRCUMFERENCE CONTROL JOINT JOINT CONTROL CAULKING CAULKING CEILING CEILING CLEAR CLEAR CENTIMETER CENTIMETER CONCRETE MASONRY MASONRY UNIT UNIT CONCRETE CLEAN OUT/CASED OUT/CASED OPENING OPENING CLEAN COLUMN COLUMN CONCRETE CONCRETE CONSTRUCTION CONSTRUCTION CONTINUOUS CONTINUOUS CORRIDOR CORRIDOR CHROME PLATED PLATED CHROME COUNTERSINK COUNTERSINK CASEMENT CASEMENT CERAMIC TILE TILE CERAMIC CENTER CENTER CLEAR WIRE WIRE GLASS GLASS CLEAR CUBIC YARDS YARDS CUBIC CH CH CI CI CIR CIR CIRC CIRC CJ CJ CLKG CLKG CLG CLG CLR CLR CM CM CMU CMU CO CO COL COL CONC CONC CONSTR CONSTR CONT CONT CORR CORR CP CP CS CS CSMT CSMT CT CT CTR CTR CWG CWG CY CY 4' 4' 0 0 1' 1' 2' 2' 3' 3' B E 16' 16' 8' 8' 4' 4' 0 0 32' 32' 16' 16' 8' 8' G G G GA GA GAL GAL GALV GALV GB GB GC GC GFCI GFCI GFGI GFGI 2' 2' 0 0 1' 1' ∠ ∠ AND AND ANGLE ANGLE AT AT CENTER LINE LINE CENTER DIAMETER DIAMETER PLATE PLATE POUND/NUMBER POUND/NUMBER F D D dB dB DBL DBL DEMO DEMO DET DET DF DF DG DG DH DH DIA DIA DIM DIM DISP DISP DL DL DN DN DP DP DR DR DS DS DWG DWG DWR DWR (E) (E) E E EA EA EF EF EG EG EGC EGC EJ EJ ELEC ELEC ELEV ELEV ENCL ENCL ENTR ENTR EQ EQ EQUIP EQUIP EIFS EIFS DEPTH DEPTH DECIBELS DECIBELS DOUBLE DOUBLE DEMOLISH/DEMOLITION DEMOLISH/DEMOLITION DETAIL DETAIL DRINKING FOUNTAIN FOUNTAIN DRINKING DAY GATE GATE DAY DOUBLE HUNG HUNG DOUBLE DIAMETER DIAMETER DIMENSION DIMENSION DISPENSER DISPENSER DEAD LOAD LOAD DEAD DOWN DOWN DAMPPROOFING DAMPPROOFING DOOR DOOR DOWNSPOUT DOWNSPOUT DRAWING DRAWING DRAWER DRAWER ESC ESC EST EST EW EW EXH EXH EXIST EXIST EXP EXP EXT EXT EXISITING EXISITING EAST EAST EACH EACH EACH FACE FACE EACH FOR EXAMPLE EXAMPLE FOR EPOXY GLAZED COATING COATING EPOXY EXPANSION JOINT JOINT EXPANSION ELECTRICAL ELECTRICAL ELEVATOR/ELEVATION ELEVATOR/ELEVATION ENCLOSURE ENCLOSURE ENTRANCE ENTRANCE EQUAL EQUAL EQUIPMENT EQUIPMENT EXTERIOR INSULATION INSULATION EXTERIOR & FINISH FINISH SYSTEM SYSTEM & ESCALATOR ESCALATOR ESTIMATED ESTIMATED EACH WAY WAY EACH EXHAUST EXHAUST EXISTING EXISTING EXPANSION/EXPANDED EXPANSION/EXPANDED EXTERIOR EXTERIOR FF FA FA FBG FBG FDN FDN FE/BR FE/BR FEW FEW FIG FIG FIN FIN FIXT FIXT FL FL FLEX FLEX FLUOR FLUOR FM FM FO FO FRT FRT FT FT FTG FTG FURN FURN FURR FURR FLAME/FLUSH FLAME/FLUSH FIRE ALARM ALARM FIRE FOIL-BACKED GYPSUM GYPSUM BOARD BOARD FOIL-BACKED FOUNDATION FOUNDATION FORCED-ENTRY/BALLISTIC-RESISTANT FORCED-ENTRY/BALLISTIC-RESISTANT FIRE EXTINGUISHER EXTINGUISHER WALL WALL MOUNTED MOUNTED FIRE FIGURE FIGURE FINISH FINISH FIXTURE FIXTURE FLASH FLOOR FLOOR FLASH FLEXIBLE FLEXIBLE FLUORESCENT FLUORESCENT FACTORY MUTUAL MUTUALRESEARCH RESEARCHCORP. CORP. FACTORY FACE OF OF FACE FIRE RETARDANT RETARDANT TREATED TREATED FIRE FOOT/FEET FOOT/FEET FOOTING FOOTING FURNITURE/FURNISHED FURNITURE/FURNISHED FURRING FURRING GENERAL NOTES: MATERIAL SYMBOLS GFE GFE GL GL GOVT GOVT GND GND GR GR GWB GWB GYP BD BD GYP H I J K L M N O P Q GUTTER GUTTER GAUGE GAUGE GALLON GALLON GALVANIZED GALVANIZED GRAB BAR/GYPSUM BAR/GYPSUM BOARD BOARD GRAB GENERAL CONTRACTOR CONTRACTOR GENERAL GOVERNMENT-FURNISHED, GOVERNMENT-FURNISHED, CONTRACTOR-INSTALLED CONTRACTOR-INSTALLED GOVERNMENT-FURNISHED, GOVERNMENT-FURNISHED, GOVERNMENT-INSTALLED GOVERNMENT-INSTALLED GOVERNMENT FURNISHED FURNISHED EQUIPMENT EQUIPMENT GOVERNMENT GLASS/GLAZED GLASS/GLAZED GOVERNMENT GOVERNMENT GROUND GROUND GRADING/GRADE GRADING/GRADE GYPSUM GYPSUM WALLBOARD WALLBOARD GYPSUM BOARD BOARD GYPSUM HC HC HD HD HDWD HDWD HDWR HDWR HH HH HM HM HOR HOR HP HP HR HR HTG HTG HT/H HT/H HVAC HVAC HOLLOW HOLLOW CORE CORE HEAD/HEAVY HEAD/HEAVY DUTY DUTY HARDWOOD HARDWOOD HARDWARE HARDWARE HAND HAND HOLE HOLE HOLLOW HOLLOW METAL METAL HORIZONTAL HORIZONTAL HORSEPOWER HORSEPOWER HOUR HOUR HEATING/HEAT HEATING/HEAT HEIGHT/HIGH HEIGHT/HIGH HEATING, VENTILATING VENTILATING HEATING, & AIR AIR CONDITIONING CONDITIONING & HZ HZ HERTZ HERTZ ID ID IG IG IIC IIC IN IN INCL INCL INFO INFO INSUL INSUL INT INT INSIDE DIAMETER/ DIAMETER/ INSIDE INTERIOR DIMENSION DIMENSION INTERIOR INSULATED GLASS GLASS INSULATED IMPACT INSULATION INSULATION CLASS CLASS IMPACT INCH INCH INCLUDING INCLUDING INFORMATION INFORMATION INSULATION INSULATION INTERIOR INTERIOR JAN JAN JB JB JST JST JT JT JANITOR JANITOR JAMB JAMB JOIST JOIST JOINT JOINT KD KD KIT KIT KO KO KPA KPA KW KW KNOCK-DOWN/KILN-DRIED KNOCK-DOWN/KILN-DRIED KITCHEN KITCHEN KNOCK OUT OUT KNOCK KILOPASCAL KILOPASCAL KILOWATT KILOWATT LL L/S L/S LAM LAM LB LB LBL LBL LF LF LG LG LH LH LL LL LP LP LT LT LTG LTG LONG LONG LITERS PER PER SECOND SECOND LITERS LAMINATE(D) LAMINATE(D) POUND/LOAD-BEARING POUND/LOAD-BEARING LABEL LABEL LINEAR FEET FEET LINEAR LONG/LENGTH LONG/LENGTH LEFT HAND HAND LEFT LIVE LOAD LOAD LIVE LOW POINT POINT LOW LIGHT LIGHT LIGHT/LIGHTING LIGHT/LIGHTING M M MAS MAS MAT/MATL MAT/MATL MAX MAX MECH MECH MED MED MEMB MEMB MET/MTL MET/MTL MFR MFR MH MH MIN MIN MIR MIR MISC MISC MIX MIX ML ML MLD MLD MM MM MO MO MS MS MT MT MTD MTD MTG MTG MULL MULL METER METER MASONRY MASONRY MATERIAL MATERIAL MAXIMUM MAXIMUM MECHANICAL MECHANICAL MEDIUM MEDIUM MEMBRANE MEMBRANE METAL METAL MANUFACTURER MANUFACTURER MOUNTING HEIGHT HEIGHT MOUNTING MINIMUM MINIMUM MIRROR MIRROR MISCELLANEOUS MISCELLANEOUS MIXTURE MIXTURE MATCH LINE LINE MATCH MOLDING MOLDING MILLIMETER MILLIMETER MASONRY OPENING OPENING MASONRY MOTOR STARTER STARTER MOTOR MARBLE THRESHOLD THRESHOLD MARBLE MOUNTED MOUNTED MOUNTING MOUNTING MULLION MULLION N N N/A N/A NIC NIC NLB NLB NO NO NOM NOM NSF NSF NTS NTS NORTH NORTH NOT APPLICABLE APPLICABLE NOT NOT IN IN CONTRACT CONTRACT NOT NON-LOAD BEARING BEARING NON-LOAD NUMBER NUMBER NOMINAL NOMINAL NATIONAL SANITATION SANITATION FOUNDATION FOUNDATION NATIONAL NOT TO TO SCALE SCALE NOT OC OC OD OD OFF OFF OH OH OPHD OPHD OPNG OPNG OPP OPP OZ OZ PA PA PC PC PCF PCF PF PF PFB PFB PLAM PLAM PLAS PLAS PLF PLF PNL PNL PNT PNT POLY POLY PR PR PRESS TR TR PRESS PRF PRF PSF PSF PT PT PRCST PRCST PVC PVC PWD PWD PTN PTN P.T. P.T. QT QT QTB QTB QUAL QUAL ON CENTER CENTER ON OUTSIDE DIAMETER DIAMETER OUTSIDE OFFICE OFFICE OVERHEAD OVERHEAD OPPOSITE HAND HAND OPPOSITE OPENING OPENING OPPOSITE HAND HAND OPPOSITE OUNCE(S) OUNCE(S) PASCAL PASCAL PORTLAND CEMENT CEMENT PORTLAND POUNDS PER PER CUBIC CUBIC FOOT FOOT POUNDS POLISH FINISH FINISH POLISH PREFABRICATE PREFABRICATE PLASTIC LAMINATE LAMINATE PLASTIC PLASTER PLASTER POUNDS PER PER LINEAR LINEAR FOOT FOOT POUNDS PANEL PANEL PAINT PAINT POLYETHYLENE POLYETHYLENE PAIR PAIR PRESSURE TREATED TREATED PRESSURE PREFINISHED PREFINISHED POUNDS PER PER SQUARE SQUARE FOOT FOOT POUNDS POINT POINT PRECAST PRECAST POLYVINYL CHLORIDE CHLORIDE POLYVINYL PLYWOOD PLYWOOD PARTITION PARTITION PRESSURE TREATED TREATEDWOOD WOOD PRESSURE QUARRY TILE TILE QUARRY QUARRY TILE TILE BASE BASE QUARRY QUALITY QUALITY R RA RA RAF RAF RAD/r RAD/r RCP RCP REBAR REBAR REC REC REF REF REGIS REGIS REINF REINF REM REM REPL REPL REQD REQD RESIL RESIL RET RET REV REV RF RF RGS RGS RH RH RM RM RO RO RWL RWL RWD RWD RETURN AIR AIR RETURN RELILIENT ATHLETIC ATHLETIC FLOORING FLOORING RELILIENT RADIUS RADIUS REFLECTED CEILING CEILING PLAN PLAN REFLECTED REINFORCING BAR BAR REINFORCING RECEPTACLE RECEPTACLE REFERENCE REFERENCE REGISTRATION REGISTRATION REINFORCING/REINFORCED REINFORCING/REINFORCED REMOVE REMOVE REPLACE REPLACE REQUIRED REQUIRED RESILIENT RESILIENT RETURN AIR AIR RETURN REVISE/REVISION REVISE/REVISION ROUGH ROUGH FINISH FINISH RIGID GALVANIZED GALVANIZED STEEL STEEL RIGID RIGHT RIGHT HAND HAND ROOM ROOM ROUGH ROUGH OPENING OPENING RAIN RAIN WATER WATER LEADER LEADER REDWOOD REDWOOD S S SA SA SAC SAC SC SC SCH SCH SDG SDG SDT SDT SECT SECT SF SF SG(#) SG(#) SH SH SHTH SHTH SIM SIM SJ SJ SM SM SPEC SPEC SQ SQ SQ SQ YD YD SQ SQ FT FT SS SS STA STA STD STD ST ST STL STL STL STL SUSP SUSP SV SV SW SW SYM SYM SYS SYS SHT, SH SH SHT, STOR STOR STRUCT STRUCT SOUTH SOUTH SUPPLY SUPPLY AIR AIR SUSPENDED SUSPENDED ACOUSTICAL ACOUSTICAL CEILING CEILING SOLID CORE CORE SOLID SCHEDULE SCHEDULE SIDING SIDING STATIC DISSIPATIVE DISSIPATIVE TILE TILE STATIC SECTION SECTION SEAMLESS FLOORING FLOORING SEAMLESS DUCT SECURITY SECURITYGRILL GRILL(TYPE (TYPE #) #) DUCT SHELF SHELF SHEATHING SHEATHING SIMILAR SIMILAR STEEL JOIST JOIST STEEL SURFACE MOUNTED MOUNTED SURFACE SPECIFICATION SPECIFICATION SQUARE SQUARE SQUARE YARD YARD SQUARE SQUARE FOOT FOOT SQUARE STAINLESS STEEL STEEL STAINLESS STATION STATION STANDARD STANDARD STAINLESS STEEL STEEL STAINLESS STEEL STEEL SUSPENDED SUSPENDED SHEET SHEET VINYL VINYL SWITCH SWITCH SYMMETRICAL SYMMETRICAL SYSTEM SYSTEM SHEET SHEET STORAGE STORAGE STRUCTURE STRUCTURE TT TB TB TC TC TELE TELE TEMP TEMP TER TER TF TF T&G T&G THK THK THR THR THRU THRU TO TO TOC TOC TOS TOS TOW TOW TW TW TYP TYP TREAD/THICK TREAD/THICK TOWEL BAR BAR TOWEL TOP OF OF CURB CURB TOP TELEPHONE/TELECOM TELEPHONE/TELECOM TEMPORARY TEMPORARY TERRAZZO TERRAZZO TROWEL FINISH FINISH TROWEL TONGUE && GROOVE GROOVE TONGUE THICK/THICKNESS THICK/THICKNESS THRESHOLD THRESHOLD THROUGH THROUGH TOP OF OF TOP TOP OF OF CONCRETE CONCRETE TOP TOP OF OF STEEL STEEL TOP TOP OF OF WALL WALL TOP TOP OF OF WALL WALL TOP TYPICAL TYPICAL UC UC UL UL UNF UNF UNO UNO URM URM UNDERCUT UNDERCUT UNDERWRITER'S LABORATORIES LABORATORIES UNDERWRITER'S UNFINISHED UNFINISHED UNLESS NOTED NOTED OTHERWISE OTHERWISE UNLESS UNREINFORCED MASONRY MASONRY UNREINFORCED V V (V) (V) VAV VAV VB VB VCB VCB VCT VCT VD VD VENT'D VENT'D VERT VERT VEST VEST VJ VJ VOL VOL VT VT VWC VWC VENT/VOLT/VALVE VENT/VOLT/VALVE VERIFY VERIFY VARIABLE AIR AIR VOLUME VOLUME VARIABLE VAPOR BARRIER BARRIER VAPOR VINYL COVE COVE BASE BASE VINYL VINYL COMPOSITION COMPOSITION TILE TILE VINYL VOLUME DAMPER/VAULT DAMPER/VAULT DOOR DOOR VOLUME VENTED VENTED VERTICAL VERTICAL VESTIBULE VESTIBULE V-JOINT V-JOINT VOLUME VOLUME VINYL TILE TILE VINYL VINYL WALL WALL COVERING COVERING VINYL W WD WD WOOD WOOD X XFMR XFMR S T U V EARTH EARTH FIBER BOARD BOARD OR OR FIBER RIGID INSULATION INSULATION RIGID GRAVEL OR OR GRAVEL POROUS FILL FILL POROUS PLASTER, PLASTER, GYPSUM GYPSUM WALL WALL BOARD, BOARD, MORTAR, MORTAR, OR OR PARTICLE PARTICLE BOARD BOARD CONCRETE CONCRETE MASONRY UNIT UNIT MASONRY FINISHED WOOD WOOD FINISHED BRICK BRICK ROUGH ROUGH WOOD WOOD STONE STONE PLYWOOD PLYWOOD CONCRETE CONCRETE STEEL OR OR IRON IRON STEEL FIBROUS FIBROUS INSULATION INSULATION ALUMINUM ALUMINUM 1. 1. CONTRACTOR CONTRACTORSHALL SHALL AT AT ALL ALL TIMES TIMES RETAIN RETAIN AN AN APPROVED SET OF PERMIT DRAWINGS ON THE CONSTRUCTION PREMISE. CONSTRUCTION PREMISE. 2. 2. CONTRACTOR CONTRACTORSHALL SHALL BE BE RESPONSIBLE RESPONSIBLE FOR OBTAINING OBTAINING ADDITIONAL ADDITIONAL TRADE TRADE PERMITS PERMITS FOR FOR ELECTRICAL, ELECTRICAL, MECHANICAL ETC. WORK AS REQUIRED. MECHANICAL ETC. WORK AS REQUIRED. 3. 3. CONTRACTOR CONTRACTORSHALL SHALL COMPLY COMPLY WITH WITH THE THE BUILDING BUILDING RULES RULES AND AND REGULATIONS REGULATIONS FOR FOR WORKING WORKING HOURS, HOURS, DELIVERY AND HANDLING OF MATERIAL, AND CONSTRUCTION WASTE REMOVAL. DELIVERY AND HANDLING OF MATERIAL, AND CONSTRUCTION WASTE REMOVAL. 4.IN ORDER TO FACILITATE MINIMUM DISRUPTION TO ROUTINE ROUTINE OPERATIONS OPERATIONS OF THE STATION, STATION, THE CONTRACTOR SHALL REQUIRE TO SCHEDULE PORTIONS OF THE CONSTRUCTION DURING WEEKENDS, AND AFTER HOURS. CONTRACTOR SHALL REQUIRE TO SCHEDULE PORTIONS OF THE CONSTRUCTION DURING WEEKENDS, AND 5. DO NOT SHORE OR HANDLE ANY CONSTRUCTION MATERIAL IN THE PATH TO EGRESS UNDER ANY AFTER HOURS. CIRCUMSTANCES. 5. DO NOT SHORE OR HANDLE ANY CONSTRUCTION MATERIAL IN THE PATH TO EGRESS UNDER ANY 6. DURING CONSTRUCTION PORTIONS OF THE BUILDING OUTSIDE OF THE SCOPE OF WORK SHALL REMAIN CIRCUMSTANCES. OCCUPIED OPERATIONAL. OCCUPIED OF THE STRUCTURE BE OF SEPARATED FROM PORTIONS 6. DURINGAND CONSTRUCTION PORTIONS OFPORTIONS THE BUILDING OUTSIDE OF THEWILL SCOPE WORK SHALL REMAIN OF THE STRUCTURE UNDERGOING ALTERATION, CONSTRUCTION, OR DEMOLITION BY TEMPORARY OCCUPIED AND OPERATIONAL. OCCUPIED PORTIONS OF THE STRUCTURE WILL BE OPERATIONS SEPARATED FROM WALLS WITH AOF MINIMUM 1-HR FIRE UNDERGOING RESISTANCE RATING IN ACCORDANCE WITH NFPA 241 §8.6.2. OPENING PORTIONS THE STRUCTURE ALTERATION, CONSTRUCTION, OR DEMOLITION OPERATIONS PROTECTIVES WILL HAVE AT LEAST A 45-MINUTE FIRE PROTECTION RATING. BY TEMPORARY WALLS WITH A MINIMUM 1-HR FIRE RESISTANCE RATING IN ACCORDANCE WITH NFPA 241 § 7. EXTREME CARE SHALL BE EXERCISED DRILLING OR ANCHORING TO THE EXISTING STRUCTURE. IF 8.6.2. OPENING PROTECTIVES WILL HAVE IN ATCUTTING, LEAST A 45-MINUTE FIRE PROTECTION RATING. ANY DETERIORATION OR DAMAGE TO THE IN EXISTING STRUCTURE OCCURS DURING IT SHALL BE 7. EXTREME CARE SHALL BE EXERCISED CUTTING, DRILLING OR ANCHORING TOCONSTRUCTION, THE EXISTING STRUCTURE. IMMEDIATELY REPORTED TO THE CITY AND ARCHITECT-ENGINEER OF THE RECORD. IF ANY DETERIORATION OR DAMAGE TO THE EXISTING STRUCTURE OCCURS DURING CONSTRUCTION, IT SHALL 8. BE RESPONSIBLE FOR ARCHITECT-ENGINEER SCHEDULING ALL CONSTRUCTION INSPECTION WITH APPROPRIATE BECONTRACTOR IMMEDIATELY SHALL REPORTED TO THE CITY AND OF THE RECORD. CODE OFFICER DURING ASFOR REQUIRED. 8. CONTRACTOR SHALLCONSTRUCTION BE RESPONSIBLE SCHEDULING ALL CONSTRUCTION INSPECTION WITH 9. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION ALL TEMPORARYAS SHORING, SUPPORT AND PROTECTION OF EXISTING APPROPRIATE CODE OFFICER DURING REQUIRED. CONDITIONS TO REMAIN DURING CONSTRUCTION. 9. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING, SUPPORT AND PROTECTION OF EXISTING 10.CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK ENVIRONMENT AND COMPLIANCE WITH OSHA CONDITIONS TO REMAIN DURING CONSTRUCTION. SAFETY STANDARD DURING CONSTRUCTION. 10. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK ENVIRONMENT AND COMPLIANCE WITH 11.CONTRACTOR SHALL COORDINATE WITH THE CITY FOR TEMPORARY SHUT DOWN OF ANY BUILDING SYSTEM OSHA SAFETY STANDARD DURING CONSTRUCTION. DURING CONSTRUCTION. 11.CONTRACTOR SHALL COORDINATE WITH THE CITY FOR TEMPORARY SHUT DOWN OF ANY BUILDING SYSTEM 12.REMOVE ANY NAILS, SCREWS, SURFACE MOUNTED RACEWAY, HARDWARE, NON-FUNCTIONING ELECTRICAL DURING CONSTRUCTION. DEVICES AND OTHER EXPOSED ITEMS ON EXISTING WALLS/PORTIONS IN THE AREA OF NEW WORK.ELECTRICAL 12.REMOVE ANY NAILS, SCREWS, SURFACE MOUNTED RACEWAY, HARDWARE, NON-FUNCTIONING 13. PATCHAND ANDOTHER REPAIR RESULTING WALL/PARTITION DAMAGE AS REQUIRED SURFACES DEVICES EXPOSED ITEMS ON EXISTING WALLS/PORTIONS IN THEPREPARING AREA OF NEW WORK. TO RECEIVE NEW FINISHES SCHEDULED. 13. PATCH ANDAS REPAIR RESULTING WALL/PARTITION DAMAGE AS REQUIRED PREPARING SURFACES TO 14.CONTRACTOR SHALL AT TIMES KEEP THE PREMISES CLEAN AND FREE OF ACCUMULATIONS OF WASTE RECEIVE NEW FINISHES ASALL SCHEDULED. MATERIAL AND RUBBISH CAUSED BY THE CONSTRUCTION. 14.CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND FREE OF ACCUMULATIONS OF WASTE 15.MANUFACTURER NAMES AND PRODUCT ARE INDICATING ON DRAWINGS TO INDICATE MINIMUM PERFORMANCE MATERIAL AND RUBBISH CAUSED BY THE CONSTRUCTION. CRITERIA. EQUALS OR COMPARABLE MAY BE SUBMITTED FOR DURING THE SUBMITTAL PROCESS. 15.MANUFACTURER NAMES AND PRODUCT ARE INDICATING ONREVIEW DRAWINGS TO INDICATE MINIMUM 16.CONTRACTOR SHALL FULLY COMPLY WITH ALL REQUIREMENTS OF "GENERAL CONDITIONS" BY THE PERFORMANCE CRITERIA. EQUALS OR COMPARABLE MAY BE SUBMITTED FOR REVIEW DURINGFURNISHED THE SUBMITTAL CITY PROCESS. 17. CONTRACTOR SHALL SHALL FULLY COORDINATE PHASING WITH THE CITY. PRIOR TO COMMENCEMENT 16.CONTRACTOR COMPLYCONSTRUCTION WITH ALL REQUIREMENTS OF "GENERAL CONDITIONS" FURNISHED BYOF ANY CONSTRUCTION ACTIVITY. THE CITY 18. DIMENSIONS FOR COORDINATE NEW WALLS ARE FROM FACE OF STUD FRAMING OTHERWISE NOTED. 17. ALL CONTRACTOR SHALL CONSTRUCTION PHASING WITH THEUNLESS CITY. PRIOR TO COMMENCEMENT 19. FORACTIVITY. NEW INTERIOR DOORS ARE TO THE CENTER OF DOORS, UNLESS OTHERWISE NOTED. OF ALL ANYDIMENSIONS CONSTRUCTION 20. RAW WOOD SEALED/PAINTED LEAD-FREE, NON -METALLIC, CLEANABLE 18. ALL EXPOSED DIMENSIONS FOR NEWSHALL WALLSBE ARE FROM FACE OFWITH STUDAFRAMING UNLESS OTHERWISEEASILY NOTED. PAINT A HIGH QUALITY VARNISH. 19. ALLFOR DIMENSIONS FOR NEW INTERIOR DOORS ARE TO THE CENTER OF DOORS, UNLESS OTHERWISE NOTED. 21. ALL ANNULAR OPENINGS IN CONSTRUCTION SHALL BE SEALED/CAULKED TO WITHIN 1/32 OF AN INCH. 22. ALL EXHAUST HOODS OVER COOKING EQUIPMENT WILL BE CAPABLE OF CAPTURING AND EXHAUSTING SMOKE GENERATED FROM A 60-SECOND SMOKE BOMB. REFERENCE SYMBOLS REFERENCE SYMBOLS WALL SECTION WALL SECTION DETAIL/ SECTION NUMBER DETAIL/ SECTION NUMBER SIMILAR INDICATION SIMILAR INDICATION SIM 1 SIM 1 A101 BUILDING SECTION BUILDING SECTION DETAIL SECTION DETAIL SECTION EXTERIOR ELEVATION EXTERIOR ELEVATION INTERIOR ELEVATION INTERIOR ELEVATION 1 1 A101 A101 LEVEL DESCRIPTION LEVEL DESCRIPTION LEVEL 1 0'-0" LEVEL 1 0'-0" FLOOR ELEVATION FLOOR ELEVATION LEVEL ELEVATION LEVEL ELEVATION SHEET NUMBER SHEET NUMBER A101 SIM SIM NEW COLUMN NEW COLUMN NEW COLUMN GRID INDICATOR NEW COLUMN GRID INDICATOR 0 0 NEW COLUMN GRID LINE COLUMN GRID NEW LINE SIM 1 SIM A101 1 A101 EXISTING COLUMN EXISTING COLUMN EXISTING COLUMN GRID INDICATOR EXISTING COLUMN GRID INDICATOR 2 2 EXISTING COLUMN GRID LINE COLUMN EXISTING GRID LINE ELEVATION NUMBER ELEVATION NUMBER 1 1 A101 A101 SHEET NUMBER SHEET NUMBER SHEET NUMBER SHEET NUMBER 1 / A103 11 / A103 A102 MATCH LINE MATCH LINE 1 / A102 SHEET NUMBER SHEET MATCHNUMBER LINE MATCH LINE ELEVATION NUMBER ELEVATION NUMBER 2 2 3 1 A601 1 A601 3 4 4 SHEET NUMBER SHEET NUMBER REVISION NUMBER (SHEET SPECIFIC) REVISION NUMBER (SHEET SPECIFIC) 1 1 REVISION REVISION CLOUDED AREA OF REVISION AREA OF CLOUDED REVISION TRANSFORMER TRANSFORMER RCP LEGEND 1 1 A101 GYPSUM CEILING CEILING GYPSUM LARGE SCALE BLOWUP OF PLAN OR DETAIL LARGE SCALE BLOWUP OF PLAN OR DETAIL A101 SIM SIM PLAN OR DETAIL NUMBER PLAN OR DETAIL NUMBER SHEET NUMBER SHEET NUMBER N N NORTH ARROW NORTH ARROW W W 2X4 ACOUSTICAL ACOUSTICAL CEILING CEILING TILE TILE 2X4 2X4 PVC PVC ACOUSTICAL ACOUSTICAL CEILING CEILING TILE TILE 2X4 2'-0" X X 2'-0" CEILING/ CASSETTE CASSETTE DIFFUSER DIFFUSER 2'-0" PARTITION TYPE PARTITION TYPE 2'-0" X X 2'-0" 2'-0" CEILING EXHAUST EXHAUST GRILLE GRILLE 2'-0" DOOR SYMBOL DOOR SYMBOL FA 24 FA 24 EXTERIOR WINDOW SYMBOL WINDOW EXTERIOR SYMBOL LOUVER SYMBOL LOUVER SYMBOL 6" RECESSED CANISTER CANISTER LIGHT LIGHT FIXTURE FIXTURE 6" W-101 W-101 L-101 L-101 CEILING SPRINKLER SPRINKLER HEAD HEAD CEILING EMERGENCY WALL WALL LIGHT LIGHT EMERGENCY TRUE NORTH TRUE NORTH ROOM NAME AND NUMBER ROOM NAME AND NUMBER PARTITION CONFIGURATION PARTITION CONFIGURATION "A" INDICATES SOUNDBATT INSULATION "A" INDICATES SOUNDBATT INSULATION FRAMING SIZE DESIGNATION FRAMING SIZE DESIGNATION FIRE-RATING/ PARTITION HEIGHT DESIGNATION FIRE-RATING/ PARTITION HEIGHT DESIGNATION SHEET NOTE SYMBOLS SHEET NOTE SYMBOLS 2 2 2 2 KEYNOTE KEYNOTE 05500 05500 DOOR OR BORROWED LIGHT NUMBER DOOR OR BORROWED LIGHT NUMBER X 44 RECESSED LIGHT LIGHT FIXTURE FIXTURE 22 X EXIT (EGRESS) (EGRESS) SIGN SIGN EXIT E E ARCHITECTURE / INTERIORS SYMBOLS ARCHITECTURE / INTERIORS SYMBOLS NEW ACOUSTIC ACOUSTIC BAFFLE BAFFLE ARRAY ARRAY NEW 2'-0' X 2'-0" CEILING ACCES PANEL PANEL 2'-0' PLAN NORTH PLAN NORTH S S 101101 2' 2' & & 0 0 IF IF THIS THIS DRAWING DRAWING IS IS A A REPRODUCTION, REPRODUCTION, GRAPHIC GRAPHIC SCALE SCALE MUST MUST BE BE USED USED ABBREVIATIONS: ROOM NAME ROOM 100NAME 100 WINDOW NUMBER WINDOW NUMBER TOILET ACCESSORY TOILET ACCESSORY WALL PROTECTION WALL PROTECTION LOUVER NUMBER LOUVER NUMBER ROOM NAME ROOM NAME ROOM NUMBER ROOM NUMBER TA-10 TA-10 CG-1 CG-1 CR-1 CR-1 HR-1 HR-1 CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com APPLICABLE CODES, APPLICABLE CODES, STANDARD AND AUTHORITY STANDARD AND AUTHORITY ALL WORK RELATED TO THIS PROJECT SHALL BE ALL WORK RELATED TO THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING PERFORMED IN ACCORDANCE WITH THE FOLLOWING CODES, AND CRITERIA AS APPLICABLE. CODES, AND CRITERIA AS APPLICABLE. • 2012 International Building Code (IBC) • 2012 International Building Code (IBC) NSF/ANSI2 Standards • NSF/ANSI2 Standards 2012 International Mechanical Code (IMC) • 2012 Code (IMC) 2012 International International Mechanical Fuel Gas Code (IFGC) • 2012 GasConservation Code (IFGC)Code (IECC) 2012 International International Fuel Energy • 2012 Energy Conservation 2012 International Life Safety Code – NFPA 101(LSC)Code (IECC) • 2012 Safety Code Code – NFPA 101(LSC) 2011 Life National Electric – NFPA 70 (NEC) • 2011 National Electric Code 70 (NEC) Maryland Accessibility Code –– NFPA ADAAG/2010 • Maryland Accessibility Code ADAAG/2010 Fire Safety Codes - The Fire –Safety Code of Montgomery • Fire Safety Codes -as The Fire Safety Code of County, Maryland, it existed on August 1, Montgomery 1996, County, Maryland, it existed on August 1, 1996, being Chapter 22 ofasthe Montgomery County Code, 1984 being Chapter 22 of the Montgomery County Code, 1984 (1994 Replacement Volume), the 2012 Editions of the (1994 Replacement Volume), the 2012 Editions the National Fire Protection Association Uniform FireofCode National Fire Protection Association Uniform Fire Code (NFPA 1) and Life Safety Code® (NFPA 101®), all (NFPA 1) and Life codes Safetyor Code® (NFPA 101®), all by associated NFPA standards incorporated associated NFPA codes or standards incorporated by reference, and the latest editions of certain other NFPA reference, and the latestby editions of certain other1 NFPA codes not incorporated reference into NFPA or NFPA codes 101® not incorporated by reference into NFPA 1 or NFPA 101® APPROVING AUTHORITY: APPROVING AUTHORITY: City of Gaithersburg City of Gaithersburg Planning and Code Administration Planning andInspections Code Administration Permits and Permits and Inspections 31 S. Summit Ave. 31 S. Summit Ave. Gaithersburg, MD 20877 Gaithersburg, 301-258-6330MD 20877 301-258-6330 301-258-6336 (fax) 301-258-6336 (fax) • Plumbing and natural gas • Plumbing Plumbing and and natural natural gas are under the authority of the Plumbing andSuburban natural are under Commission the authority (WSSC), of the Washington Sanitary which Washington Suburban Commission (WSSC), which currently uses the 2012Sanitary International Plumbing Code (IPC) currently usesInternational the 2012 International Plumbing Code (IPC) and the 2012 Fuel Gas Code (IFGC) and the 2012 International Fuel Gas Code (IFGC) • Health review, when required, is performed by the • Health review,County when required, is performed by the Montgomery Department of Health and Human Montgomery County Department of Health and Human Services, Regulatory Division - 240-777-398 Services, Regulatory Division - 240-777-398 DEMOLITION NOTE NUMBER DEMOLITION NOTE NUMBER NEW CONSTRUCTION NOTE NUMBER NEW CONSTRUCTION NOTE NUMBER SPECIFICATION SECTION SPECIFICATION SECTION SHELF ANGLE SHELF ANGLE SPECIFIED ITEM SPECIFIED ITEM TOILET ACCESSORY NUMBER TOILET ACCESSORY NUMBER Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 No. Date Revisions Drawing Title GENERAL NOTES, ABBREVIATIONS & SYMBOLS Phase CONCEPT A/E Project Number 12-0009.015 Date CORNER GUARD NUMBER CORNER GUARD NUMBER CRASH RAIL NUMBER CRASH RAIL NUMBER HAND RAIL NUMBER HAND RAIL NUMBER Description 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 1:1 Number A002 SCALE: 1-1/2" = 1'-0" 2' 1' 0 SCALE: 1" = 1'-0" 2' 1' 0 1/2' 3' SCALE: 3/4" = 1'-0" 2' 1' 0 SCALE: 1/2" = 1'-0" 4' 2' 1' 0 SCALE: 1/4" = 1'-0" 8' 4' 2' 0 SCALE: 3/16" = 1'-0" 12' 8' 4' ARCHITECTURAL: ELECTRICAL: MECHANICAL: PLUMBING STORAGE ROOM: 1. FIRE RATED DOOR AND HARDWARE 2. VCT FLOOR TILE PRODUCT DATA AND SAMPLE 3. FLOORING TRANSITION CONFERENCE ROOM: 1. FIRE RATED DOOR AND HARDWARE 2. CONFERENCE TABLE 3. SIX(6) CONFERENCE CHAIRS 4. CABINETS PRODUCT DATA AND SAMPLE 5. CARPET PRODUCT DATA AND SAMPLE 6. SUSPENDED CEILING SYSTEM 7. WALL PAINT 8. QUARTZ BASED COUNTERTOP MATERIAL PRODUCT DATA AND SAMPLE 9. FLOORING TRANSITIONS BATHROOM: 1. DOOR 2. CEILING SYSTEM 3. WALL TILE PRODUCT DATA AND SAMPLE 4. VCT FLOOR TILE PRODUCT DATA AND SAMPLE 5. MIRROR 6. SOAP DISPENSER 7. TOILET PAPER HOLDER 8. SANITARY NAPKIN DISPOSAL 9. FLOORING TRANSITIONS KITCHEN: 1. STAINLESS STEEL ISLAND TABLE 2. STAINLESS STEEL L TABLE 3. REFRIGERATOR 4. FREEZER 5. SUSPENDED CEILING SYSTEM 6. WALL TILE PRODUCT DATA AND SAMPLE 7. FLOOR TILE PRODUCT DATA AND SAMPLE 8. FLOORING TRANSITIONS 9. ROOF CURB SHOP DRAWINGS 10. SHEET METAL LOADING DOCK (NEXT TO KITCHEN) 1. SUSPENDED CEILING SYSTEM 2. FLOORING TRANSITIONS TEEN ROOM: 1. ACOUSTIC CEILING BAFFLES 2. WALL AND CEILING PAINT DANCE STUDIO: 1. ACOUSTIC CEILING BAFFLES 2. WALL AND CEILING PAINT MULTIPURPOSE ROOM: 1. SUSPENDED CEILING SYSTEM 2. WALL PAINT 3. CARPET 4. FLOORING TRANSITIONS ROOMS A, B & C 1. FLOOR TILE PRODUCT DATA AND SAMPLE 2. FLOORING TRANSITIONS 1. ELECTRICAL DEVICES 2. ELECTRICAL EQUIPMENT (PANELS, DISCONNECTS, MOTOR RATES SWITCHES) 3. WIRING, CONDUITS, AND FITTINGS 4. LIGHT FIXTURES 5. COMMON ELECTRICAL MATERIALS (JUNCTION BOXES, SUPPORTS, FITTINGS, ETC.) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. KITCHEN 1. THREE COMPARTMENT SINK 2. GREASE INTERCEPTOR 3. ICEMAKER 4. COMMERCIAL DISHWASHER 5. HAND SINK 6. MOPE SINK 7. PVC DRAIN AND VENT PIPE 8. CPVC WATER PIPE STORAGE 1. WASHER/DRYER 2. WATER CLOSET 3. LAVATORY SPLIT SYSTEM ERU ELECTRICAL HEATING COIL EXHAUST FAN MAKE UP FAN CABINET UNIT HEATERS DUCTWORK SHOP DRAWINGS AND PRODUCT DATA SYSTEM LAYOUT FIELD COORDINATION SHOP DRAWING CONTROLS AND TAB SETTINGS SEQUENCE OF OPERATIONS TAB REPORT CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 No. Description Date SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 THE FOLLOWING LIST INFORMS OF THE ESSENTIAL TECHNICAL SUBMITTALS REQUIRED AT MINIMUM. HOWEVER, THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL RELEVANT SUBMITTALS FOR THE ENTIRE PROJECT'S PROCUREMENT. PROVIDE CALCULATIONS AS NECESSARY. IN ADDITION, PROVIDE ADMINISTRATIVE SUBMITTAL AS REQUIRED BY THE SOLICITATION. Revisions Drawing Title LIST OF REQUIRED SUBMITTALS Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED LIST OF REQUIRED SUBMITTALS 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 1:1 Number A003 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' SCALE: 1" = 1'-0" 1' A200 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 3 2 A400 2 4 A401 KITCHEN 1 3' 0 1/2' 4 20' - 4" LOADING DOCK 1 NIKA A+E UP SCALE: 3/4" = 1'-0" 1' 2' ROOM C 6 6 A401 4' 0 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com ROOM A ROOM B 7 UP SCALE: 1/2" = 1'-0" 0 1' 2' 5 MAIN LOBBY SCALE: 1/4" = 1'-0" 1 A400 A600 5 A401 9 6 SCALE: 3/16" = 1'-0" 8' 4' 0 3 A400 A300 16' SCALE: 1/8" = 1'-0" 8' 2 9 3 8 OFFICE Revisions Drawing Title SCOPE OF WORK FIRST FLOOR OVERALL PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date MECHANICALELECTRICAL ROOM 1 A201 Description OFFICE CONFERNECE ROOM 4 4' CORRIDOR No. STORAGE ROOM 0 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 UP 12' 0 2' 4' 8' 10 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 A100 FIRST FLOOR OVERALL PLAN E W 3/16" = 1'-0" N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 1 100% 1:1 Number A100 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' SCALE: 1" = 1'-0" 1' 0 1/2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 2 3' A300 3 NIKA A+E A300 SCALE: 3/4" = 1'-0" UP DN 1 A407 RCP SCALE: 1/2" = 1'-0" DANCE STUDIO TEEN ROOM 9 UP E 1 A406 RCP Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' 4' 0 1' 2' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/16" = 1'-0" No. Description Date ROOM F SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' UP Revisions 1 A403 F Drawing Title SCOPE OF WORK SECOND FLOOR OVERALL PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION 1 A300 S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 A101 SECOND FLOOR OVERALL PLAN E W 3/16" = 1'-0" N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 1 100% 1:1 Number A101 SCALE: 1-1/2" = 1'-0" 1' 2' NEW EXHAUST FAN OVER EXISTING ROOF CURB GOOSENECKAIR INTAKE 1. ANY EXISTING ROOF AND ROOFING WARRANTY MUST BE MAINTAINED DURING AND AFTER CONSTRUCTION. FLASH AND COUNTERFLASH THE ENTIRE INSTALLATION THROUGHOUT. 2. ALL ROOF WORK SHALL BE PERFORMED BY A QUALIFIED ROOFING INSTALLER. 3. PROCURE THE ROOF CURB WITH THE SAME MATERIAL AS THE EXISTING STANDING SEAM METAL ROOF. INSTALL PER MANUFACTURER'S INSTRUCTION. 4. ALL METAL TO METAL LAP CONNECTIONS WILL BE WEATHER SEALED WITH MASTIC TAPE AND BUTYL CAULKING ALL AROUND. ALL INSTALLATIONS WILL BE MECHANICALLY FASTENED. SCALE: 1" = 1'-0" 0 1/2' 1' 2' 0 NOTES: 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 BIRD SCREEN 5. ORDER THE CURB WITH CONSIDERATIONS OF DUCT SIZE, REQUIRED CLERANCES, HEIGHT ABOVE ROOF AND ROOF PITCH. PROVIDE SHOP DRAWINGS FOR REVIEW. GOOSENECK AIR INTAKE. SEE MECH. FOR DUCT SIZE 6. BIRD SCREEN MUST BE PROVIDED FOR GOOSENECK INTAKE METAL DIVERTER CRICKET Sim DUCT FLANGE. MECHANICALLY TIE-IN WITH WOOD NAILER. INSTALL RIB COVER WHERE RIB IS CUT. WATER BLOCK WITH BUTYL CAULK AND MASTIC TAPE. MECHANICALLY FASTEN. CURB METAL FLASHING TO BE NOTCHED 3" MIN. AT RIB CUT LOCATION MANUFACTURER REQD. CLEARANCE (TYP.) SCALE: 3/4" = 1'-0" 2' 1' 0 4' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com DO NOT CUT EXISTING STRUCTURE AT ANY PLACE. DUCT. REFER TO MECHANICAL DRAWINGS. NEW STRUCTURAL FRAMING UNDER ROOF CUT LOCATION. SECURE AND INTEGRATE WITH EXISTING STRUCTURAL FRAMING. SCALE: 1/2" = 1'-0" 2' 1' INSTALL MANUFACTURER RECOMMENDED INSULATED, AND FULLY WELDED ON ALL FOUR SIDE, CURB SUPPORT. CURB MATERIAL WILL BE G-90 GALVANIZED STEEL OR 0.064 IN. ALUMINUM - DESIGNED FOR PITCHED ROOFS. INSTALL RIB COVER WHERE RIB IS CUT. WATER BLOCK WITH BUTYL CAULK AND MASTIC TAPE. MECHANICALLY FASTEN. CURB METAL FLASHING TO BE NOTCHED 3" MIN. AT RIB CUT LOCATION EXISTING STANDING SEAM MTL. ROOF ON 4" RIGID INSUL. w/ AIR BARRIER ON MTL. DECK FIRESTOP AT ALL GAPS AS REQD. CROSS SECTION VIEW AT NEW EXHAUST FAN CURB 8' 0 NIKA A+E SNAP COUNTERFLASHING ALL AROUND. ATTACH TO 2" WOOD NAILER PROVIDED ON TOP OF CURB SUPPORT. 14" (HT) 3' 2 A102 SLOPE ROOF PANELS 3" PANEL LAP SCALE: 1/4" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 CURB TOP NAILER DUCT SCALE: 3/16" = 1'-0" No. 2 A102 SCALE: 1/8" = 1'-0" 8' 4' 0 Description GOOSENECK DETAIL 1" = 1'-0" Revisions 1 A102 ROOF PLAN Drawing Title SCOPE OF WORK 1/8" = 1'-0" ROOF OVERALL PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date ROOF PLAN VIEW AT NEW GOOSENECK AIR INTAKE 16' 0 4' 8' 12' 0 2' 4' CLEARANCE 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A102 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' 0 8' - 6" SCALE: 3/4" = 1'-0" 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1' 3' SCALE: 1" = 1'-0" 1' COORDINATE STAGING AREA WITH PROGRAM DIRECTOR 2' 0 1/2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E COVER ALL PIPES IN THIS AREA. SEE A401 SCALE: 1/2" = 1'-0" A201 8' 0 1' 2' 4' UP 8 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 SCALE: 1/4" = 1'-0" NEW LIGHT POLE NEW EXISTING FENCED MECHANICAL YARD SCALE: 3/16" = 1'-0" 1 A103 SITE PLAN No. 3/64" = 1'-0" Description Date SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 9 Revisions Drawing Title SCOPE OF WORK SITE PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model 1:1 Drawn By Author Checked By Checker Sheet E 100% Number A103 2' # 1. INSTALL NEW ICEMAKER Sim 2. INSTALL NEW TABLE SCALE: 1-1/2" = 1'-0" 0 1' 7 A600 3. INSTALL NEW REFRIGERATOR/FREEZER CASEY COMMUNITY CENTER INTERIOR RENOVATION 4. INSTALL NEW DISHWASHER 8' - 0" 2' 8' - 0" 5. INSTALL NEW KITCHEN TABLE WITH SINKS AND FLANGE FEET (ACCESSORY S-31) 6. INSTALL NEW DOOR. SEE A600 SCALE: 1" = 1'-0" 0 1/2' 1' 7. REINSTALL STOVE, RANGE AND HOOD AFTER COMPLETING CONSTRUCTION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 8. INSTALL NEW PEDESTAL HAND SINK 7 3 6 4 5 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 0 1 A200 KITCHEN SOUTH 3 1/2" = 1'-0" A200 KITCHEN WEST 1/2" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1/4" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 8' - 0" Sim 8' - 0" SCALE: 3/16" = 1'-0" 6 A600 No. Description Date 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' 8 2' 1 5 6 2 2 1 Revisions SCALE: 1/8" = 1'-0" 0 4' 8' 4 Drawing Title SCOPE OF WORK FIRST FLOOR ELEVATION KITCHEN Phase 32' CONCEPT A/E Project Number SCALE: 1/16" = 1'-0" 8' 16' 2 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED NEW CONSTRUCTION LEGEND A200 KITCHEN NORTH 1/2" = 1'-0" 4 A200 KITCHEN EAST 12-0009.015 Date 1/2" = 1'-0" S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A200 NEW CONSTRUCTION LEGEND A300 # 1. INSTALL NEW DOOR 100 3. INSTALL NEW BASE CABINETS 8 A201 Sim 9 CASEWORK DETAIL 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 1/2" = 1'-0" DUPONT ZODIAQ QUARTZ CONTERTOP 1 2 3 3 2 1' - 3" 1 3 1/2" = 1'-0" A201 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" CONFERENCE WEST 1/2" = 1'-0" 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" 0 2' - 11" NIKA A+E 1' 3' A201 CONFERENCE SOUTH 2' - 0" 2' SCALE: 1" = 1'-0" 1' A201 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 2' - 11" 90 Sim 0' - 4" 5 A600 2. INSTALL NEW CONFERENCE TABLE AND CHAIRS 0' - 1" 8' - 0" Sim 8' - 0" SCALE: 1-1/2" = 1'-0" 3 A600 2' 0 1' 2' - 0" TECHLINE CASEWORK B332-24-35-24-9-2-W15 B332-24-35-24-9-2-W15 B430-24-35-24-9-0-W15 B430-24-35-24-9-0-W15 B129-24-35-24-9-0-W15 B129-24-35-24-9-1-W15 B332-15-35-24-9-0-W15 SCALE: 1/2" = 1'-0" 8' - 0" 8 9 A201 A201 Sim CASEWORK FRONT DETAIL TECHLINE HARDWARE 1/2" = 1'-0" PULL: 0161-0154000000 SLIMLINE 128 PULL MATTE NICKEL FINISH HINGE: 0361-0093000000 CONCEALED HINGE 8' 0 1' 2' 8' - 0" 4' TRANSITION BETWEEN EXISTING AND NEW WALL MUST BE SEAMLESS SCALE: 1/4" = 1'-0" 2 A201 2 2 CONFERENCE NORTH 4 1/2" = 1'-0" A201 DRAWER SLIDES: 0461-0673000000 24" DEEP SLIDES CONFERENCE EAST 1/2" = 1'-0" ROLLER CATCH: 0261-1410000000 PART 1 0263-1398000000 PART 2 12' 0 2' 4' 3 LOCK: TO MATCH CABINET TYPE AND PULL FINISH 5 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 SCALE: 3/16" = 1'-0" EXISTING R.O. HEIGHT 3' - 0" EXISTING V.I.F. Description Date V.I.F. EXISTING V.I.F. V.I.F. No. EXISTING R.O. EDGE V.I.F. 7' - 3" V.I.F. 7' - 0" V.I.F. 4' - 1 1/4" Revisions Drawing Title SCOPE OF WORK FIRST FLOOR ELEVATION CONFERENCE ROOM AND ENTRIES 2' - 0" KK 2' - 0" 3' - 0" V.I.F. KK 2' - 0" 3' - 0" 120 2' - 6" 2' - 6" 3' - 0" 110 7' - 0" V.I.F. 4' - 1 1/4" SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' A300 Phase 32' CONCEPT NEW DOOR HARDWARE FIRST FLOOR 0' - 0" NEW DOOR HARDWARE FIRST FLOOR 0' - 0" FIRST FLOOR 0' - 0" A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' 6 S 5 A201 SOUTH ENTRY 3/8" = 1'-0" 6 A201 NORTH ENTRY 3/8" = 1'-0" 7 A201 LOBBY WINDOW 1/2" = 1'-0" 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A201 SCALE: 1-1/2" = 1'-0" 2' NEW SCREW CONNECTING CHANNEL TO RAFTER 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 SCALE: 1" = 1'-0" CEILING FINISH 5' - 3" 1' 0 0 1/2' 1' 2' EXISTING HORIZONTAL ROOF RAFTER NEW FINISHED STEEL CHANNEL 3' BOLT WITH NUT THROUGH CHANNEL NIKA A+E 2' - 0" NEW CABLE WITH EYE LOOP ON EACH END (KIT) NEW EYE LOOP CARABINER (KIT) SCALE: 3/4" = 1'-0" 1' 2' EYE HOOK MOUNTING BRACKET (KIT) SOUNDSOAK BAFFLE 2X4 (KIT) TEEN ROOM 4 A300 4' 0 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com BAFFLE CONNECTION DETAIL 3" = 1'-0" 5 ENTRY A300 3/8" = 1'-0" FF SCALE: 1/2" = 1'-0" NEW LINTEL. 2 STEEL ANGLES 5X3-1/2X1/4 (LLV) @ EACH SIDE OF NEW OPENING 2 A300 TEEN ROOM SECTION 6 Sim A300 3/8" = 1'-0" 0' - 8" MIN OPENING NAILER SECURED TO CMU R.O. HEIGHT STEEL ANGLE 5X3-1/2X1/4 6' - 8 1/2" R.O. HEIGHT NEW OPENING LESS THAN 4' WIDE DRYWALL WRAP UNDER STEEL ANGLE 12' METAL DOOR FRAME NAILER SEAL AROUND DOOR FRAME NEW DOOR. SEE A600 FOR HEIGHT SCALE: 3/16" = 1'-0" 4' 8' 4 A300 6 A300 CONFERENCE DOOR LINTEL DETAIL 7 1" = 1'-0" A300 CONFERENCE DOOR STRUCTURE No. 1/2" = 1'-0" Description Date DANCE STUDIO SCALE: 1/8" = 1'-0" 0 0' - 0" Revisions 10' - 5 1/2" Drawing Title SCOPE OF WORK 7' - 3 1/4" 4' 8' 16' 0 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 EXISTING FURRING SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' 11' - 7 1/2" ROOM SECTIONS AND DETAILS ROOM F Phase 32' CONCEPT FF FF 11' - 7 1/2" A/E Project Number 12-0009.015 11' - 7 1/2" SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION S 3 A300 DANCE STUDIO SECTION 3/8" = 1'-0" 1 A300 ROOM F SECTION 3/8" = 1'-0" 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A300 R.O. R.O.FOR FOR3'3'--0" 0"xx6'-8" 6'-8" DOOR DOORIN IN EXIST.CMU EXIST.CMUWALL WALL -- INSTALL INSTALLNEW NEWLINTEL LINTEL DEMOLITION GENERAL NOTES DEMOLITION GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE APPLICABLE LOCAL CODE REGULATIONS AND ORDINANCES. ORDINANCES. 6 6 66 9 9 15 CORRIDOR CORRIDOR 2. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH THE LATEST EDITION OF THE OCCUPATIONAL OCCUPATIONAL SAFETY AND HEALTH HEALTH ACT (OSHA). 3. ALL SLAB PENETRATIONS PENETRATIONS TO TO BE BE FILLED & PREPARED PREPARED FOR NEW FINISHES AS REQUIRED. SCALE: 1-1/2" = 1'-0" 0 1' 66 4. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO START OF WORK. WORK. 17 17 16 16 APARTMENT APARTMENT 55 14 14 6. COORDINATE WITH ELECTRICAL DRAWINGS FOR REMOVAL OF LIGHT FIXTURES, SWITCHES, CONDUIT, CONDUIT, AND RELATED RELATED WIRING AND SUPPORT SYSTEMS. SYSTEMS. (TYP.) 55 2' 7. COORDINATE WITH PLUMBING DRAWINGS FOR LOCATIONS OF EXISTING EXISTING FLOOR FLOOR PENETRATIONS PENETRATIONS TO BE PATCHED AND LOCATIONS OF NEW FLOOR PENETRATIONS FOR SENTRY LINES. PATCHED AND LOCATIONS OF NEW SCALE: 1" = 1'-0" 1' 0 1/2' 8. COORDINATE WITH FINISH & EQUIPMENT EQUIPMENT PLAN TO PROVIDE ADDITIONAL BLOCKING FOR LOCATIONS OF WALL MOUNTED MOUNTED ITEMS. OFFICE OFFICE 22 55 9. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING, SUPPORT SUPPORT AND PROTECTION OF EXISTING CONSTRUCTION TO REMAIN DURING DEMOLITION AND NEW CONSTRUCTION. CONSTRUCTION TO REMAIN A201 A201 88 99 10. AFTER DEMOLITION, CONTRACTOR TO FUR AND PATCH ALL ALL FINISHES, FINISHES, WALL CLADDINGS, WALL PENETRATIONS, PENETRATIONS, FIRE FIRE SEPARATIONS, WEATHERPROOFING AND REPAIR ALL DAMAGES CAUSED TO EXISTING BUILDING DURING DEMOLITION PROCESS AS REQUIRED. EXISTING 3' OFFICE OFFICE 22 2' SCALE: 3/4" = 1'-0" 1' DEMOLITION DEMOLITION KEY KEY NOTES NOTES APARTMENT APARTMENTAND ANDBATHROOM BATHROOM PLAN PLAN-- ENLARGED ENLARGED--DEMOLITION DEMOLITION SCALE: 1/2" = 1'-0" 3/8" 3/8"==1'-0" 1'-0" 11. REMOVE (SCRAP) EXISTING GREASE INTERCEPTOR 12. REMOVE (SCRAP) EXISTING HAND-WASH SINK 15 13. REMOVE (SCRAP) EXISTING DISHWASHER 14. REMOVE EXISTING EXISTING ELECTRICAL PANEL. PANEL. REFER REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 15. SAW CUT AND REMOVE EXTENT OF EXISTING SLAB-ON-GRADE FOR NEW PLUMBING PIPES. REFER TO PLUMBING PLUMBING DRAWINGS DRAWINGS FOR FOR ADDITIONAL INFORMATION. FIELD COORDINATE LAYOUT. 16. REMOVE (SCRAP) EXISTING PLUMBING FIXTURES. SCALE: 1/4" = 1'-0" 4' 2' 33 EXISTING W/D W/D AND AND SAFELY STORE AWAY FOR REUSE. 17. REMOVE EXISTING 18. REMOVE EXISTING AIR CONDITIONING UNITS. FILL AND AND FINISH FINISH ROUGH ROUGH OPENING OPENING TO MATCH MATCH EXTERIOR AND INTERIOR FINISH. INTERIOR --- MAIN LOBBY 12' 0 14 14 SCALE: 3/16" = 1'-0" 12 12 8' # 1. REMOVE (SCRAP) EXISTING EXISTING WINDOW WINDOW AND FRAMING. SAW CUT AND REMOVE CMU WALL BELOW FROM SILL TO FLOOR WITHIN WINDOW R.O. WIDTH WIDTH EXTENTS EXTENTS 2. REMOVE (SCRAP) EXISTING FLOORING, UNDERLAYMENT AND ADHESIVE DOWN TO EXISTING SLAB. PREPARE PREPARE SUBSTRATE SUBSTRATE SURFACE SURFACE TO TO RECEIVE RECEIVE NEW NEW FLOORING. REMOVE EXISTING CEILING AND FIXTURES. REMOVE PREPARE SURFACES REMOVE ALL ALL WALL WALL TILES IN KITCHEN. PREPARE SURFACES TO RECEIVE NEW NEW WALL TILES. 3. SAFELY STORE REFRIGERATOR/FREEZER FOR RELOCATION 4. REMOVE (SCRAP) METAL KITCHEN COUNTERS AND SINKS. 5. REMOVE (SCRAP) DOOR AND HARDWARE 6. REMOVE EXISTING WALL 7. REMOVE (SCRAP) EXISTING KITCHENETTE, FLOOR AND OVERHEAD CABINETS. CAP EXISTING PLUMING AT SINK. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 8. REMOVE REFRIGERATOR IN EXISTING APARTMENT AND STORE TEMPORARILY 9. REMOVE (SCRAP) BATHTUB. BATHTUB. CAP EXISTING PLUMBING. PLUMBING. REFER TO PLUMBING FOR ADDITIONAL INFORMATION. 10. REMOVE (SCRAP) EXISTING ICEMAKER. 15 4' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 12. TEMPORARY TEMPORARY STORAGE FOR EXISTING EXISTING EQUIPMENT EQUIPMENT WILL WILL BE SPECIFIED BY THE CITY 18 18 8' 0 1' 2' 4' 0 --- 33 NIKA A+E 11. CONTRACTOR SHALL INSTALL TEMPORARY CNSTRUCTION PARTITION TO PREVENT PREVENT ANY DISRUPTION TO OCCUPIED SPACES THROUGHOUT CONSTRUCTION. - A400 A400 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 8. KEY NOTES ARE PROVIDED FOR ADDITIONAL CLARITY OF BUILDING BUILDING CONDITIONS CONDITIONS AND AND SHALL NOT LIMIT THE OVERALL OVERALL SCOPE SCOPE OF OF WORK. WORK. 66 0 CASEY COMMUNITY CENTER INTERIOR RENOVATION 5. COORDINATE WITH MECHANICAL DRAWINGS FOR REMOVAL OF DUCTS, VENTS, RADIATORS, REGISTERS/DIFFUSERS, WINDOW A/C UNITS UNITS AND AND SUPPORT SYSTEMS. (TYP.) 77 88 1 A201 7 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 LOADING LOADING DOCK DOCK 66 No. 13 13 KITCHEN KITCHEN Description Date 22 55 16' 10 10 11 SCALE: 1/8" = 1'-0" 0 4' 8' 44 11 11 - 1 --- A400 A400 ENTRANCE - ENLARGED Revisions 1'-0" 3/8" = 1'-0" Drawing Title SCOPE OF WORK FIRST FLOOR ENLARGED PLANS - DEMOLITION 11 11 Phase CONCEPT 32' 55 A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' 0'0'--3" 3"MIN MIN ROOMAA ROOM S 22 A400 A400 KITCHENPLAN PLAN--ENLARGED ENLARGED--DEMOLITION DEMOLITION KITCHEN 3/8"==1'-0" 1'-0" 3/8" 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A400 2' 2' MIN MIN 16 16 TOILET TOILET 12 12 12 10 10 14 14 14 ALIGN ALIGN - 12 12 12 5. NEW STAINLESS STEEL (SS)(SS) PREPARATION COUNTER WITH STORAGE 5. NEW STAINLESS STEEL PREPARATION COUNTER WITH STORAGE 11 11 33 100 100 - 111 6. NEW DISHWASHER WITH VENT EXHAUST. REFER PLUMBING AND 6. NEW DISHWASHER WITH VENT EXHAUST. REFER TO TO PLUMBING AND ELECTRICAL ELECTRICAL DRAWINGS FR ADDITIONAL INFORMATION. DRAWINGS FR ADDITIONAL INFORMATION. 11 CONFERENCE CONFERENCE T3 T3 22 242 242SF SF 0'0'- -2" 2" 2' 2' EQ ALIGN ALIGN ALIGN 17 17 17 12 12 OFFICE OFFICE 22 SCALE: 1" = SCALE: 1" = 1'-0" 1'-0" 111 444 A201 38 3 38 A201 8 A201 219 219SF SF 219 SF 99 2 2 29 6' - 0". 444 V.I.F. STORAGE STORAGE STORAGE EQ EQ 16 16 13' --- 3 1/4" 13' 13' 33 1/4" 1/4" 18 18 18 3' 3' OFFICE OFFICE 6' 6' -- 0". 0". EQ SCALE: 3/4" 3/4" = = 1'-0" 1'-0" SCALE: 2' 2' 4 SCALE: = 1'-0" 1'-0" SCALE: 1/2" 1/2" = CONFERENCE CONFERENCEROOM ROOMAND ANDOFFICES OFFICES--ENLARGED ENLARGED 3/8" = 1'-0" 21. 4 A401 SOUTH STOREFRONT ENTRY DOOR 10 3/8" = 1'-0" 414 SF 19 MAIN LOBBY 3' - 0 1/2" +/- V.I.F 10 414 SF SCALE: SCALE: 1/4" 1/4" = = 1'-0" 1'-0" 4' 4' 2' 2' EXISTING OVERHEAD EXHAUST HOOD AND STOVE TO BE REINSTALLED IN SAME LOCATION. EXHAUST HOOD STERLING EQUIPMENT CO., INC. 19 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 3' - 0 1/2" +/- V.I.F 3 A401 MAIN LOBBY ENTRANCE - ENLARGED 3/8" = 1'-0" 12' 12' 0 0 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com MAIN LOBBY 3/8" 3/8"===1'-0" 1'-0" 3/8" 1'-0" 8' 8' 0 0 1' 1' 2' 2' 22 A401 A401 A401 NIKA A+E 16. NEW QUARTZ BASED WALLBOARD COUNTERTOP WITH BACKSPLASH 17. INSTALL NEW GYPSUM AROUND NEW ELECTRICAL PANEL. PREPARE WALL SURFACE TO RECEIVE NEW FINISH 17. INSTALL NEW GYPSUM WALLBOARD AROUND NEW ELECTRICAL PANEL. PREPARE WALL SURFACE TO CHAIRS RECEIVE NEW FINISH 18. NEW CONFERENCE TABLE AND SOUTH STOREFRONT ENTRY DOOR 4' 4' A401 3 A401 MAIN LOBBY ENTRANCE - ENLARGED 3/8" = 1'-0" EQ SCALE: 3/16" 3/16" = = 1'-0" 1'-0" SCALE: 888 1B 1B 777 10 10 10 6' -EQ 0". 16' 16' 999 444 T4 T4 T5 KITCHEN KITCHEN KITCHEN 6 99 A401 111 6 66 319SF SF 319 319 SF 33 6'EQ - 0". SCALE: 1/8" = = 1'-0" 1'-0" SCALE: 1/8" 4' 4' 8' 8' 222 555 V.I.F. 13 13 111 444 A200 A200 333 A200 EXISTING PIPES AGAINST EXTERIOR WALL EXISTING PIPES AGAINST EXTERIOR WALL NEW METAL PIPE DUCT No. Description - A401 PIPE COVER PLAN DETAIL NEW METAL PIPE DUCT METAL PIPE COVER RUNNING LENGTH OF PIPES, SECURED TO EXISTING WALL AND PAINTED TOCOVER MATCHRUNNING EXTERIORLENGTH FINISH.OF METAL PIPE COVER IS TO BE CAPPED TO PREVENT PIPES, SECURED TO EXISTING WALL AND RAIN PENETRATION BUT ALLOW FOR PAINTED TO MATCH EXTERIOR FINISH. PROPER VENTILATION OF THE CAVITY COVER IS TO BE CAPPED TO PREVENT RAIN PENETRATION BUT ALLOW FOR PROPER VENTILATION OF THE CAVITY Revisions 1/2" = 1'-0" PIPE COVER PLAN DETAIL 1/2" = 1'-0" Drawing Title SCOPE OF OF WORK WORK SCOPE FIRST FLOOR ENLARGED PLANS --- T5 Phase 32' 32' CONCEPT A/E Project Number 12-0009.015 5 A401 Date NORTH STOREFRONT ENTRY DOOR EQ SCALE: SCALE: 1/16" 1/16" = = 1'-0" 1'-0" 8' 8' 16' 16' 555 T4 T4 3/8" = 1'-0" SS 13 13 13 A401 A401 A401 KITCHENPLAN PLAN--ENLARGED ENLARGED KITCHEN 3/8"===1'-0" 1'-0" 3/8" 1'-0" 3/8" 35% 60% 90% 5 A401 NORTH STOREFRONT ENTRY DOOR 3/8" = 1'-0" W W NN 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet EE 11 Date LOADING LOADINGDOCK DOCK 21 21 V.I.F. 0 0 4' 4' 8' 8' 20 20 0 0 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 18. NEW CONFERENCE TABLE AND CHAIRS 19. NEW ALUMINUM STOREFRONT WITH THERMAL BREAK AND DOUBLE PANE INSULATED GLAZING AT MAIN LOBBY. STOREFRONT WIDTH SHALL BE SAME AS EXISTING ROUGH OPENING 19. NEW ALUMINUM STOREFRONT WITH THERMAL BREAK AND DOUBLE PANE INSULATED GLAZING AT MAIN LOBBY. STOREFRONT WIDTH SHALL BE SAME 20. REFILL AREA WHERE SLAB WAS REMOVED WITH NEW SLAB AFTER INSTALLING AS EXISTING ROUGH OPENING EQUIPMENT 20. REFILL AREA WHERE SLAB WAS REMOVED WITH NEW SLAB AFTER INSTALLING EQUIPMENT EQ EQ 1' 1' 0 0 T5 13' 13'---4" 4" 13' 4" 7. NEW BEVERAGE AIR MODEL: HR1W-1S REFRIGERATOR AND NEW BEVERAGE 7. NEW REFRIGERATOR AND FREEZER AIR MODEL: HF1W-1S FREEZER 8. NEW HAND WASH PEDESTAL SINK 8. NEW HAND WASH PEDESTAL SINK 9. NEW PEDESTAL MOP SINK 9. NEW PEDESTAL MOP SINK 10. NEW W.C. 10. NEW W.C. 11. NEW SINK 11. NEW SINK 12. NEW FIRE RATED DOOR - 90 MINUTE 12. NEW FIRE RATED DOOR - 90 MINUTE 13. NEW DOOR ASSEMBLEY 13. NEW DOOR ASSEMBLEY 14. NEW LOCATION OF FREEZER/REFRIGERATOR RELOCATED FROM EXISTING KITCHEN 14. NEW LOCATION OF FREEZER/REFRIGERATOR RELOCATED FROM EXISTING 15. NEW LOCATION OF WASHER-DRYER. KITCHEN CASEY COMMUNITY CENTER INTERIOR RENOVATION 15. NEW LOCATION OF COUNTERTOP WASHER-DRYER. 16. NEW QUARTZ BASED WITH BACKSPLASH T5 V.I.F. V.I.F. 1' 1' 3. NEW STAINLESS STEEL (SS)(SS) KITCHEN COUNTER WITH THREE BOWL SINK 3. NEW STAINLESS STEEL KITCHEN COUNTER WITH THREE BOWL SINK T2 T2 15 15 15 0 1/2' 0 1/2' 2. NEW BASE CABINETS WITH LAMINATED FINISH 2. NEW BASE CABINETS WITH LAMINATED FINISH 4. NEW MOVABLE STAINLESS STEEL (SS)(SS) ISLAND COUNTER 4. NEW MOVABLE STAINLESS STEEL ISLAND COUNTER SCALE: SCALE: 1-1/2" 1-1/2" = = 1'-0" 1'-0" 0 0 1' 1' T1 T1 T1 CORRIDOR CORRIDOR 1'1'- -551/4" 1/4" 1'1'- -881/2" 1/2" 20 ## 1. NEW PARTITION WALL 1. NEW PARTITION WALL 6'6'- -001/2" 1/2"HOLD HOLD 90 90 90 0 0 IF IF THIS THIS DRAWING DRAWING IS IS A A REPRODUCTION, REPRODUCTION, GRAPHIC GRAPHIC SCALE SCALE MUST MUST BE BE USED USED NEW NEW WORK KEY NOTES 666 A300 A300 A300 1:1 Number A401 2' NOTES: SCALE: 1-1/2" = 1'-0" 2. EXISTING SPRINKLERS THAT ARE LOCATED WHERE NEW LIGHTS OR NEW CEILING EQUIPMENT WILL REQUIRE RELOCATION TO AN ADJACENT CEILING TILE AND SHALL BE SPACED PER NFPA 13 REQUIREMENTS. TOILET 3 CONFERENCE 2 STORAGE 8" MIN 1' 0 1. EXISTING FIRE SPRINKLERS WILL REQUIRE THE DROP TO BE ADJUSTED FOR THE NEW CEILING HEIGHTS. J J SCALE: 1" = 1'-0" 0 1/2' 1' J 4. EXISTING P.A. SYSTEM SPEAKERS AND OCCUPANCY CENSORS TO BE REINSTALLED AFTER CEILING REPLACEMENT OFFICE A201 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 5. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION 1 4 CASEY COMMUNITY CENTER INTERIOR RENOVATION 3. ALL NEW SPRINKLER PIPING AND EQUIPMENT SHALL BE TESTED PER NFPA 13 AND CITY OF GAITHERSBURG REQUIREMENTS. 2' 4 3 FOR RCP LEGEND SEE SHEET A002 3' 2 NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" 4' 0 1' 2' BULKHEAD 1 APARTMENT AND BATHROOM REFLECETED CEILING PLAN SCALE: 1/2" = 1'-0" 3/8" = 1'-0" SCALE: 1/4" = 1'-0" 5 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 A300 MAIN LOBBY A201 10 7 SCALE: 3/16" = 1'-0" 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' A402 KITCHEN LOADING DOCK 1 1B No. 4 16' A200 3 ENTRANCE REFLECTED CEILING PLAN 3/8" = 1'-0" Revisions Drawing Title SCOPE OF WORK FIRST FLOOR ENLARGED REFLECTED CEILING PLANS Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date 3 A402 SCALE: 1/8" = 1'-0" 8' 4' 0 Description 1 2 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 6 A300 S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 A402 KITCHEN REFLECTED CEILING PLAN E W 3/8" = 1'-0" N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 2 100% 1:1 Number A402 # SCALE: 1-1/2" = 1'-0" NEW WORK KEY NOTE # CASEY COMMUNITY CENTER INTERIOR RENOVATION 1. INSTALL NEW FLOOR FINISH, REFINISH GYP. BD, PAINT FINISH AND SUSPENDED CEILING SYSTEM. SCALE: 1" = 1'-0" 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 ROOM F 1 F 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1 A300 SCALE: 1/2" = 1'-0" 1 A403 COMPUTER ROOM "ROOM F" - ENLARGED DEMOLITION 3/8" = 1'-0" SCALE: 1/4" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 SCALE: 3/16" = 1'-0" No. TELECOM EQUIPMENT RM 1 Description Date ROOM F F Revisions SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' TELECOM EQUIPMENT RM 2' 0 1/2' 1' 2' 0 1' 1. REMOVE EXISTING FLOOR FINISH, WALL COVERING AND SUSPENDED CEILING SYSTEM. Drawing Title SCOPE OF WORK SECOND FLOOR ENLARGED PLAN - COMPUTER ROOM F DEMOLITION AND NEW WORK Phase CONCEPT 32' 1 A300 A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' DEMOLITION KEY NOTE 2 A403 COMPUTER ROOM "ROOM F" - ENLARGED S 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 Drawn By PG Checked By AV 3/8" = 1'-0" Sheet E W N CADD Plot Scale Revit Model 1:1 Number A403 2' 1' SCALE: 1-1/2" = 1'-0" 2. EXISTING SPRINKLERS THAT ARE LOCATED WHERE NEW LIGHTS OR NEW CEILING EQUIPMENT WILL REQUIRE RELOCATION TO AN ADJACENT CEILING TILE AND SHALL BE SPACED PER NFPA 13 REQUIREMENTS. 4. EXISTING P.A. SYSTEM SPEAKERS AND OCCUPANCY CENSORS TO BE REINSTALLED AFTER CEILING REPLACEMENT SCALE: 1" = 1'-0" 1' 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 3. ALL NEW SPRINKLER PIPING AND EQUIPMENT SHALL BE TESTED PER NFPA 13 AND CITY OF GAITHERSBURG REQUIREMENTS. 2' 0 1. EXISTING FIRE SPRINKLERS WILL REQUIRE THE DROP TO BE ADJUSTED FOR THE NEW CEILING HEIGHTS. 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 5. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION SCALE: 1/2" = 1'-0" TELECOM EQUIPMENT RM 0 8' 0 1' 2' 4' SCALE: 3/4" = 1'-0" 3' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1' NIKA A+E 2' FOR RCP LEGEND SEE SHEET A002 SCALE: 1/4" = 1'-0" F Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 12' 0 2' 4' ROOM F 1 SCALE: 3/16" = 1'-0" No. 1 A405 Description Date COMPUTER ROOM "ROOM F" REFLECETED CEILING PLAN 3/8" = 1'-0" SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' A300 Revisions Drawing Title SCOPE OF WORK SECOND FLOOR ENLARGED REFLECTED CEILING PLAN ROOM F Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED NOTES: S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A405 2' 1' SCALE: 1-1/2" = 1'-0" 2. EXISTING SPRINKLERS THAT ARE LOCATED WHERE NEW LIGHTS OR NEW CEILING EQUIPMENT WILL REQUIRE RELOCATION TO AN ADJACENT CEILING TILE AND SHALL BE SPACED PER NFPA 13 REQUIREMENTS. 4. EXISTING P.A. SYSTEM SPEAKERS AND OCCUPANCY CENSORS TO BE REINSTALLED AFTER CEILING REPLACEMENT SCALE: 1" = 1'-0" 1' 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 3. ALL NEW SPRINKLER PIPING AND EQUIPMENT SHALL BE TESTED PER NFPA 13 AND CITY OF GAITHERSBURG REQUIREMENTS. 2' 0 1. EXISTING FIRE SPRINKLERS WILL REQUIRE THE DROP TO BE ADJUSTED FOR THE NEW CEILING HEIGHTS. 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 5. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION 3' FOR RCP LEGEND SEE SHEET A002 NIKA A+E SPRINKLER CONE NOT TO BE OBSTRUCTED BY SUSPENDED BAFFLES 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" 2 A300 SCALE: 1/2" = 1'-0" SCALE: 1/4" = 1'-0" PERPENDICULAR OBSTRUCTION NEGLIGIBLE Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 TEEN ROOM E SCALE: 3/16" = 1'-0" No. Description Date Revisions SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 1' 2' SUSPENDED BAFFLE (TYP) Drawing Title SCOPE OF WORK SECOND FLOOR ENLARGED REFLECTED CEILING PLAN -TEEN ROOM E Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED NOTES: S 1 A406 TEEN ROOM "ROOM E" REFLECTED CEILING PLAN 3/8" = 1'-0" 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A406 2' 1' SCALE: 1-1/2" = 1'-0" 2. EXISTING SPRINKLERS THAT ARE LOCATED WHERE NEW LIGHTS OR NEW CEILING EQUIPMENT WILL REQUIRE RELOCATION TO AN ADJACENT CEILING TILE AND SHALL BE SPACED PER NFPA 13 REQUIREMENTS. 4. EXISTING P.A. SYSTEM SPEAKERS AND OCCUPANCY CENSORS TO BE REINSTALLED AFTER CEILING REPLACEMENT SCALE: 1" = 1'-0" 1' 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 3. ALL NEW SPRINKLER PIPING AND EQUIPMENT SHALL BE TESTED PER NFPA 13 AND CITY OF GAITHERSBURG REQUIREMENTS. 2' 0 1. EXISTING FIRE SPRINKLERS WILL REQUIRE THE DROP TO BE ADJUSTED FOR THE NEW CEILING HEIGHTS. 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 5. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION 3' NIKA A+E 2' FOR RCP LEGEND SEE SHEET A002 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SPRINKLER CONE NOT TO BE OBSTRUCTED BY SUSPENDED BAFFLES SCALE: 3/4" = 1'-0" 3 A300 SCALE: 1/2" = 1'-0" SCALE: 1/4" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 DANCE STUDIO 9 SCALE: 3/16" = 1'-0" 4 Sim No. A300 Description Date Revisions SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 1' SUSPENDED BAFFLE (TYP) Drawing Title SCOPE OF WORK SECOND FLOOR ENLARGED REFLECTED CEILING PLAN DANCE STUDIO Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED NOTES: S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 A407 DANCE STUDIO REFLECTED CEILING PLAN E W 3/8" = 1'-0" N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 1 100% 1:1 Number A407 Fire Room Name Room Wall Rating STORAGE SOUTH 60-MIN CONFERENCE SOUTH N/A BATHROOM NORTH N/A KITCHEN NORTH N/A KITCHEN WEST N/A NORTH ENTRY EAST SOUTH ENTRY EAST 1 SCALE: 1-1/2" = 1'-0" 0 1' KITCHEN A201 Frame Type METAL METAL WOOD METAL METAL ALUMINUM ALUMINUM Frame Finish PAINT1 PAINT1 PAINT1 PAINT1 PAINT1 DARK BRONZE DARK BRONZE Door Material METAL METAL WOOD METAL+LITE METAL GLASS GLASS ROOM FINISH SCHEDULE - FIRST FLOOR Height 6' - 8" 6' - 8" 6' - 8" 6' - 8" 6' - 8" 7' - 0" 7' - 0" Width 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" HW HW 1 HW 2 HW 3 HW 4 HW 4 HW 5 HW 5 Transition Type T1 ALUM. T2 ALUM. T3 ALUM. T4 ALUM. T4 ALUM. T5 ALUM. T5 ALUM. Transition From-To VCT1-VCT2 CARPET-VCT1 CARPET-VCT2 TILE-LVT TILE-LVT VCT-CONCRETE VCT-CONCRETE 2' Key SCALE: 1" = 1'-0" ROOM A ROOM B 5 7 ACT-PVC M8206KL ACT MAIN LOBBY 10 3' 0 1/2' 1' AQ220 1 1B 2 3 4 5 6 7 TOILET Description Manufacturer UNGLAZED QUARRY TILE VINYL ACOUSTIC TILE MODULAR CARPET ACOUSTIC CEILING TILE METROPOLITAN CERAMICS PROSERIES MANNINGTON ARMSTRONG Model SCALE: 3/4" = 1'-0" J AQ220 VCT M8206KL VCT VCT A51830 A51830 A51830 Color 108 ACT-PVC ACT-PVC ACT ACT ACT PAINT FOR CONCRETE GYP A51830 GYPSUM BOARD LUXURY VINYL TILE ARMSTRONG 51830 ZODIAQ QUARTZ COUNTERTOP DUPONT ZODIAQ TW15BW BASE CABINETS TECHLINE FRP FIBERGLASS REINF. PANELS CRANE W15 BRIGHTON WALNUT IVORY 84 Finish CHESTNUT BROWN WHITE TAN WHITE SMOOTH-PRO KEY LARGO 8206 ULTIMA PAINT1 PAINT2 Wall Finish Comments FRP Ceiling Height 8' - 0" 9' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" PAINT1 PAINT1 PAINT1 CASEY COMMUNITY CENTER INTERIOR RENOVATION Size UNGLAZED 6"x6" PVC DYED FINE TEXTURE 2'x4' 2'x2' 2'x4' Comments 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 MATCH EXISTING PAINT, LEVEL 3 SHERWIN WILLIAMS B58W610, B58V600 WHITE SEMI-GLOSS STANDARD GYPSUM BOARD 3 J Floor Finish KITCHEN LOADING DOCK CONFERENCE TOILET STORAGE ROOM A ROOM C ROOM B COTTAGE TAN MOCHA LATTE BRIGHT WALNUT IVORY 6 2' 1' 0 Name Ceiling Finish FINISH LEGEND - FIRST FLOOR 6 A201 Number 5 ROOM C 12"x12" NIKA A+E POLISHED LAMINATE 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SEE A201 FOR CASEWORK DETAILS SMOOTH 4'X8' J J FURNITURE AND EQUIPMENT SCHEDULE NSF Bolted Certification in Place J Equipment Type Manufacturer Model # Overall Dimensions KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN 3-SINK TABLE ISLAND TABLE CORNER L TABLE PEDESTAL SINK KITCHEN SINK GREASE INTERCEPTOR DISHWASHER ICEMAKER SERVICE SINK 2F3-2424-36L 1TG-30108 3TCBX-6096 HSA-10-FA-P F3L SERIES W/FAUCET MODEL # B-0230 8200 SERIES W/EXTENSION, PCN/FLG # 8250 180CB (CORNER LOCATION) INDIGO 1106 Z-1996-24 30"Dx112"Wx42"H 30"Dx108"Wx35"H 24"Dx60"Wx96"Lx39"H 19"Dx15"Wx39"H 114"Lx30"Wx42"H 35"Lx20"Wx24" 25"Lx25"Wx72"H 34"Lx30"Wx45"H 24"Dx24"Lx10"H YES YES YES YES YES YES YES YES YES YES NO NO YES YES YES NO NO YES CONFERENCE CONFERENCE CONFERENCE TABLE CONFERENCE CHAIRS AERO AERO AERO EAGLE AERO JAY R SMITH CMA MANITOWOC LIGHT COMMERCIAL HON ALLSTEEL HUDDLE 30X60 RECTANGULAR (2) INSPIRE INST-NGONO W/ CASTERS 60"Wx60"L 22"Dx24"Wx36"H NO NO NO NO SCALE: 1/2" = 1'-0" STORAGE CONFERENCE 4 2 FIRST FLOOR FINISH SCHEDULE - RCP 2 A600 3/32" = 1'-0" SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' 4' Name Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 KITCHEN BI-DIRECTIONAL DOOR 1 LOADING DOCK T4 A201 5 T5 102 RO RO RO RO RO 3' - 0" 3' - 0" 3' - 0" 1B 110 3' - 0" 3' - 0" 0' - 7" 1' - 11" 2' - 6" T4 ROOM C 101 6' - 8" RO 6' - 8" RO ROOM B 7 UP 102 No. 3' - 7" 5 100 6' - 8" 6' - 8" RO SCALE: 3/16" = 1'-0" 8' 4' 0 ROOM A 29 90 RO 6 6' - 8" 101 RO 12' UP Description Date MAIN LOBBY 16' 10 CONFERENCE 3 A600 STORAGE 4 A600 1/2" = 1'-0" 1/2" = 1'-0" 5 A600 BATHROOM 1/2" = 1'-0" 6 A600 KITCHEN N. 1/2" = 1'-0" 7 A600 KITCHEN W. 1/2" = 1'-0" SCALE: 1/8" = 1'-0" A201 6 T5 29 90 T1 T2 T3 100 A201 120 110 8 CONFERENCE 4 2 2' - 6" STORAGE 2' - 6" SCALE: 1/16" = 1'-0" 8' 16' 9 NEW DOOR HARDWARE NEW DOOR HARDWARE 1 A600 Revisions HARDWARE KEYS: 120 32' 0 4' 8' UP 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' DOOR SCHEDULE FIRST FLOOR FINISH SCHEDULE - PLAN 3/32" = 1'-0" 8 A600 NORTH ENTRY DOOR 3/8" = 1'-0" 9 A600 SOUTH ENTRY DOOR 3/8" = 1'-0" HW 1 : STORAGE FUNCTION, LEVER, LATCH, MORTICE LOCKSET - SECURE LOCK. CLOSER, 10" SS KICK PLATE INSIDE. THRESHOLD. HARDWARE WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY HW 2 : OFFICE FUNCTION, LEVER , MORTICE LOCKSET. COAT HOOK, CLOSER. THRESHOLD. SILENCERS. HARDWARE WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY HW 3 : RESTROOM FUNCTION, LEVER, CLOSER,THUMBTURN INSIDE WITH SAFETY OVERRIDE FROM OUTSIDE, COAT HOOK, 10" SS KICK PLATE OUTSIDE HW 4: STORAGE FUNCTION, LEVER, SURFACE MOUNTED LEVER LOCKSET, CLOSER, 10" SS KICK PLATE BOTH SIDES. THRESHOLD. HARDWARE WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY. HW 5: EXTERIOR CONTROL ACCESS ENTRANCE FUNCTION. MAG LOCK INTEGRATED WITH BUILDING SECURITY(INSIDE), EXIST DEVICE (PUSH BAR), THRESHOLD, DUST SWIPE, GASKET, MORTICE LOCKSET (EMERGENCY ELECTRONIC OVERRIDE). MATCH EXISTING EXIT DEVICE. KEY ENTRY FROM OUTSIDE, KEYMARK BY MEDCO. Drawing Title FIRST FLOOR FINISH SCHEDULE Phase CONCEPT A/E Project Number 12-0009.015 Date S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet E 100% 1:1 Number A600 2' SCALE: 1-1/2" = 1'-0" 9 E F Name DANCE STUDIO TEEN ROOM ROOM F Floor Finish M8206KL Ceiling Finish AB6605 AB6605 ACT Wall Finish Wall Finish 2 PAINT1 PAINT1 PAINT1 Comments ADD WALL PAINT AS ALTERNATIVE ADD WALL PAINT AS ALTERNATIVE CASEY COMMUNITY CENTER INTERIOR RENOVATION SCALE: 1" = 1'-0" 0 1/2' 1' 2' 0 1' Number 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 DANCE STUDIO FINISH LEGEND - SECOND FLOOR 9 Key M8206KL ACT 3' TEEN ROOM ROOM F SCALE: 3/4" = 1'-0" 1' 2' AB6605 Manufacturer MODULAR CARPET ACOUSTIC CEILING TILE MANNINGTON ARMSTRONG Model KEY LARGO 8206 ULTIMA Color Finish Size TAN DYED 2'x2' WHITE FINE TEXTURE 2'x4' F Comments NIKA A+E MATCH EXISTING PAINT, LEVEL 3 ARMSTRONG SUSPENDED ACOUSTIC SOUND BAFFLE 6605 WHEAT FABRIC 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 2'x4' 4' 0 Description PAINT1 E SCALE: 1/2" = 1'-0" 2 A601 SECOND FLOOR FINISH SCHEDULE - RCP HW 1 : STORAGE FUNCTION, LEVER, LATCH, MORTICE LOCKSET - SECURE LOCK. CLOSER, 10" SS KICK PLATE INSIDE. THRESHOLD. HARDWARE WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY 3/32" = 1'-0" HW 2 : OFFICE FUNCTION, LEVER , MORTICE LOCKSET. COAT HOOK, CLOSER. THRESHOLD. SILENCERS. HARDWARE WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY HW 3 : RESTROOM FUNCTION, LEVER, CLOSER,THUMBTURN INSIDE WITH SAFETY OVERRIDE FROM OUTSIDE, COAT HOOK, 10" SS KICK PLATE INSIDE HW 4: SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' HARDWARE KEYS: Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed architect under the laws of the State of Maryland, license number 15975, expiration date 10.16.2015 STORAGE FUNCTION, LEVER, MORTICE LOCKSET, CLOSER, 10" SS KICK PLATE BOTH SIDES. THRESHOLD. HARDWARE WILL BE INTEGRAL TO MANUFACTURER SUPPLIED RATED ASSEMBLY. HW 5: EXTERIOR CONTROL ACCESS ENTRANCE FUNCTION. MAG LOCK INTEGRATED WITH BUILDING SECURITY(INSIDE), EXIST DEVICE (PUSH BAR), THRESHOLD, DUST SWIPE, GASKET, MORTICE LOCKSET (EMERGENCY ELECTRONIC OVERRIDE) 5 12' A201 SCALE: 3/16" = 1'-0" DN No. Description Date DANCE STUDIO 9 UP Revisions SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' UP Drawing Title TEEN ROOM A201 6 SECOND FLOOR FINISH SCHEDULE E Phase 32' CONCEPT A/E Project Number SCALE: 1/16" = 1'-0" 8' 16' ROOM F 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED ROOM FINISH SCHEDULE - SECOND FLOOR 12-0009.015 Date F S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 A601 SECOND FLOOR FINISH SCHEDULE - PLAN E W 3/32" = 1'-0" N CADD Plot Scale Revit Model Drawn By PG Checked By AV Sheet 1 100% 1:1 Number A601 POWER SYMBOLS ABBREVIATIONS GENERAL NOTES NON FUSED DISCONNECT SWITCH PANEL BOARD, NORMAL POWER JUNCTION BOX, MOUNTING AS INDICATED MOUNTED J X A AFC AFF AMPERES ABOVE FINISHED CEILING ABOVE FINISHED FLOOR 1. ALL WORK SHOWN IS DIAGRAMMATIC AND IS FOR CIRCUIT ALLOCATION ONLY. THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL EQUIPMENT. COORDINATE ALL DEVICE LOCATIONS WITH ACTUAL DOOR SWINGS, CABINETS, COUNTERS, ETC., AS INDICATED IN ARCHITECTURAL DRAWINGS. AFG AIC ABOVE FINISHED GRADE AMPERES INTERRUPTING CAPACITY 2. REFER TO ALL CONTRACT DOCUMENTS FOR POSSIBLE INTERFERENCES, BEFORE BID IS MADE. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO HAVE MADE SUCH EXAMINATIONS OR OF ANY ERROR ON HIS PART. ATS AUTOMATIC TRANSFER SWITCH 3. ALL DISCONNECTS SHALL HAVE A SEPARATE GROUND BAR AND A NEUTRAL BAR. BC BFC BFG BARE COPPER BELOW FINISHED CEILING BELOW FINISHED GRADE 4. ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING SIGNAGE) OF EQUIPMENT LOCATION, SPARE, OR SPACE. UPDATE DIRECTORIES FOR ALL ALTERED PANELS. LABEL AND IDENTIFY ALL JUNCTION BOXES WITH PANEL AND CIRCUIT NUMBER. C CONDUIT 5. SEPARATE NEUTRAL CONDUCTORS TO BE RUN WITH ALL BRANCH CIRCUITS. CAB CCTV CKT CABINET CLOSED CIRCUIT TELEVISION CIRCUIT 6. ALL CIRCUITS TO BE RUN WITH GREEN GROUNDING CONDUCTOR SIZED PER NEC 250.122. CLG COTR CP 7. MOUNTING HEIGHTS OF ALL DEVICES ARE TO CENTER OF DEVICE, OUTLET, FIXTURE OR EQUIPMENT UNLESS OTHERWISE NOTED. CT'S CEILING CONTRACTING OFFICER CONTROL PANEL CURRENT TRANSFORMERS 8. CONSOLIDATION OF INDIVIDUAL CONDUIT HOME RUNS SHOWN ON THE DRAWINGS SHALL NOT BE PERMITTED WITHOUT PRIOR WRITTEN APPROVAL. LIGHTING AND RECEPTACLE CIRCUITS ONLY MAY BE EXEMPTED, LIMITED TO NOT MORE THAN THREE CIRCUITS PER CONDUIT HOMERUN. CTR CU COUNTER COPPER 9. PROVIDE GROUNDING TYPE EXPANSION FITTINGS OR OTHER APPROVED METHODS TO ALLOW FOR EXPANSION, CONTRACTIONS AND DEFLECTION WHERE CONDUITS CROSS EXPANSION JOINTS. DEMO DS DEMOLITION DISCONNECT SWITCH DWG DRAWING(S) 10. ALL EMPTY CONDUITS SHALL BE FURNISHED WITH PULL-WIRE AND WILL BE STUBBED-UP A.F.F., OR ABOVE SUSPENDED CEILING AS THE CASE MAY BE, AND SHALL BE CAPPED AT BOTH ENDS. EF EM EXHAUST FAN EMERGENCY 11. NUMBER OF BENDS IN A CONDUIT SECTION RUN SHALL NOT EXCEED FOUR 90-DEGREE BENDS, OR EQUIVALENT OF SWEEPS AND RADIUS BENDS. EMT EQUIP EWC ELECTRICAL METALLIC TUBING EQUIPMENT ELECTRIC WATER COOLER 12. ALL LOW VOLTAGE COMMUNICATIONS WIRING SHALL BE ROUTED IN EMT CONDUITS, OR OTHER APPROVED CONDUITS, EXCEPT WHERE RUN IS CONCEALED IN ACCESSIBLE AREAS. ALL EXPOSED WIRING SHALL BE PLENUM RATED AND SUPPORTED AS REQUIRED BY CODE. EWH ETR EX FLA FLUOR ELECTRIC WATER HEATER EXISTING TO REMAIN EXISTING FULL LOAD AMPERES FLUORESCENT 13. WIRING FOR ALL LOW VOLTAGE COMMUNICATION SYSTEMS SHALL BE RUN IN DEDICATED RACEWAYS AND NOT SHARED WITH POWER WIRING OR OTHER SYSTEMS. 14. VERIFY MECHANICAL EQUIPMENT SWITCH AND CONNECTION REQUIREMENTS, ITEM BY ITEM WITH THE MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN AND WIRING OF EQUIPMENT. RESOLVE ALL DISCREPANCIES WITHOUT FURTHER COST TO THE OWNER. GEC GROUNDING ELECTRODE CONDUCTOR 15. GEN ENGINE GENERATOR SET WHERE MOUNTING HEIGHTS ARE NOT DETAILED, INSTALL ELECTRICAL SERVICES AND OVERHEAD EQUIPMENT TO PROVIDE MAXIMUM HEADROOM POSSIBLE. INSTALL ELECTRICAL EQUIPMENT TO FACILITATE MAINTENANCE, REPAIR AND REPLACEMENT OF EQUIPMENT AND COMPONENTS AS MUCH AS PRACTICAL. CONNECT THE EQUIPMENT FOR EASE OF DISCONNECTING WITH MINIMUM OF INTERFERENCE WITH OTHER INSTALLATIONS. GFCI GROUND FAULT CIRCUIT INTERRUPTER 16. GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACT DOCUMENTS THAT DO NOT CHANGE THE SCOPE OF INSTALLATION OR NATURE OF WORK REQUIRED, THE CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL COSTS TO COTR. NO OTHER CHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION OF THE COTR. GFS GROUND FAULT SENSOR GND GROUND 17. GYP GYPSUM HGT HEIGHT WHERE THE CONTRACTOR REQUESTS APPROVAL OF AN ITEM OF EQUIPMENT WHICH DEVIATES FROM THE REQUIREMENTS OF THE DRAWINGS AND WILL REQUIRE A REDESIGN OF STRUCTURE, PARTITIONS, FOUNDATIONS, PIPING, WIRING, OR ANY OTHER PART OF THE MECHANICAL, ELECTRICAL, OR ARCHITECTURAL LAYOUT, ALL SUCH REDESIGN, AND ALL NEW DRAWINGS AND DETAILING REQUIRED THEREFORE, SHALL BE PREPARED AND PAID FOR BY THIS CONTRACTOR AND SUBMITTED TO THE ARCHITECT FOR APPROVAL. HID HPS HOA HIGH INTENSITY DISCHARGE HIGH PRESSURE SODIUM HAND-OFF-AUTOMATIC 18. HP HV INC JB HORSEPOWER HIGH VOLTAGE INCANDESCENT JUNCTION BOX PROVIDE ALL POWER WIRING FOR POWER, WIRING SHALL INCLUDE FEEDERS, BRANCH CIRCUITS, DISCONNECT SWITCHES, EQUIPMENT TERMINALS. DISCONNECTS SHALL BE PROVIDED IN ACCORDANCE WITH CODE REQUIREMENTS WHETHER OR NOT SPECIFICALLY INDICATED ON DRAWINGS. 19. KV KVA KVAR KILO-VOLTS KILO-VOLTS-AMPERES KILO-VOLTS-AMPERES REACTIVE ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE ENFORCED EDITION OF THE NATIONAL ELECTRICAL CODE, N.F.P.A. 70, AND ALL LOCAL AND STATE CODES AND REGULATIONS. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY THE BUILDING AND SAFETY CODES AND ORDINANCES, AND THE RULES AND REGULATIONS OF ANY LEGAL BODY HAVING JURISDICTION. 20. ALL ELECTRICAL ITEMS, MATERIALS, DEVICES, APPLIANCES SHALL BE U.L. LABELED. KW KWH LAN LTG m KILO-WATTS. KILO-WATT-HOURS LOCAL AREA NETWORK LIGHTING METER 21. ALL NECESSARY ADDITIONS AND ALTERATIONS TO EXISTING WORK SHALL BE INCLUDED IN THE CONTRACT AS REQUIRED TO PROVIDE AND MAINTAIN A COMPLETE AND PROPER ELECTRICAL INSTALLATION. THIS WORK SHALL INCLUDE: MM MAX MCB MCC MILLIMETER MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MCP MFR MOTOR CIRCUIT PROTECTOR MANUFACTURER WORK TO BE DEMOLISHED/REWORKED EXISTING TO REMAIN NEW WORK GFCI 125V, DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER, NEMA 5-20R, WALL RECESSED MOUNTED 18" AFF, UON. PROVIDE HOT, NEUTRAL, AND GROUND WIRES. 125V, DUPLEX RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 18" AFF, UON. PROVIDE HOT, NEUTRAL, AND GROUND WIRES. 125V, SIMPLEX RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 18" AFF, UON. PROVIDE HOT, NEUTRAL, AND GROUND WIRES. 125V, QUADRUPLEX RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 18" AFF, UON. PROVIDE HOT, NEUTRAL, AND GROUND WIRES. 220V, SPECIAL PURPOSE RECEPTACLE, NEMA 6-20R, WALL RECESSED MOUNTED 18" AFF, UON 125V, DUPLEX FLOOR RECEPTACLE, NEMA 5-20R, FLOOR RECESSED MOUNTED, UON RECEPTACLE SUFFIXES XX" AFF GFCI = GROUND FAULT CIRCUIT INTERRUPTER REF = REFRIGERATOR FRZ = FREEZER R AC CTR W = MOUNT DEVICE AT INDICATED INCHES AFF TO CENTER = WASHING MACHINE DW = DISH WASHER IM = ICE MACHINE = RANGE = AIR CONDITIONER = 125V, COUNTERTOP RECEPTACLE, NEMA 5-20R, WALL RECESSED MOUNTED 6" ABOVE COUNTER, UON COMMUNICATION SYMBOLS DATA OUTLET, WALL RECESSED MOUNT, 18" AFF UON. TELEPHONE OUTLET, WALL RECESSED MOUNT, 18" AFF UON. LIGHTING FIXTURE SYMBOLS WALL MOUNTED LED FIXTURE SURFACE MOUNTED FLUORESCENT 1'x4' SURFACE MOUNTED CIRCULAR LIGHT 12" LED POLE LAMP FIXTURE LENSED RECESSED FLUORESCENT FIXTURE 2'x4' CEILING RECESSED MOUNTED 6" LED DOWNLIGHT RECESSED FLUORESCENT FIXTURE 2'x2' LED EXIT SIGN AND EMERGENCY LIGHT COMBO LED EXIT SIGN OS CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SUSPENDED CEILING FAN WITH LIGHT EMERGENCY DUAL HEAD FIXTURE S 20A, REGULAR VOLTAGE - 120V SINGLE POLE, GRADE SWITCH. WALL MOUNT AT 48" AFF TO CENTER UON S 20A, REGULAR VOLTAGE - 120V SINGLE POLE, GRADE SWITCH. WALL MOUNT AT 48" AFF TO CENTER UON 3 S 120V SINGLE POLE, 1HP MOTOR RATED SWITCH S OCCUPANCY SENSOR SWITCH M OS DIRECT/INDIRECT RECESSED FLUORESCENT TROFFER FIXTURE 2'x4' DIRECT/INDIRECT RECESSED 2'x4' TROFFER LIGHT FIXTURE EQUIPPED WITH EMERGENCY BATTERY BALLAST MGB MH MAIN GROUND BAR METAL HALIDE MIN MISC MTR MINIMUM MISCELLANEOUS MOTOR MTD MTG NEC PNL PRI PVC MOUNTED MOUNTING NATIONAL ELECTRICAL CODE PANEL PRIORITY POLYVINYL CHLORIDE RCP REFLECTED CEILING PLAN REC RGS TEL TUNG TYP UC UFC UH V VA RECEPTACLE RIGID GALVANIZED STEEL TELEPHONE TUNGSTEN TYPICAL UNDERGROUND COMMUNICATION UNIFIED FACILITIES CRITERIA UNIT HEATER UNLESS OTHERWISE NOTED UNDERGROUND POWER UNINTERRUPTIBLE POWER SUPPLY UNDERGROUND SECURITY VOLTS VOLT-AMPERES VFC W WHE VARIABLE FREQUENCY CONTROLLER WATTS WAREHOUSE WP XFMR WEATHER PROOF TRANSFORMER UON UP UPS US 22. a. RELOCATION OF PULL BOXES, RACEWAYS, ETC., TO PERMIT THE INSTALLATION OF NEW EQUIPMENT. b. DISCONNECTION/RECONNECTIONS/REMOVAL/REINSTALLATION OF ELECTRICAL SUPPLY, CONTROL, AND UTILIZATION EQUIPMENT REQUIRED FOR CONTINUED OPERATION, INCLUDING TEMPORARY WORK AS REQUIRED. c. PROVISIONS FOR THE RELOCATION OF ALL PIPING, DUCTWORK, ETC., AS REQUIRED FOR ELECTRICAL WORK, WHERE NOT SHOWN OR SPECIFIED BY OTHERS. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE A/E TEAM PRIOR TO BID SO THAT THE APPROPRIATE TRADE MAY BE ASSIGNED TO BID; OTHERWISE, THE ELECTRICAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL SUCH RELOCATIONS. d. EQUIPMENT TO BE TURNED OVER TO OWNER, SHALL BE TURNED OVER IN CLEAN AND WORKING CONDITION. e. DISCONNECT ELECTRICAL SERVICES TO EQUIPMENT TO BE REMOVED. REMOVE ALL UNUSED CONDUIT AND CONDUCTORS BACK TO POINT OF SERVICE, OR NEXT ACTIVE DEVICE, UNLESS THEY ARE TO BE REUSED UNDER NEW CONSTRUCTION. f. UNUSED CONDUITS CAN BE ABANDONED WHERE CONCEALED IN FLOORS OR WALLS, BUT MUST BE REMOVED FROM CEILING SPACES, EXPOSED AREAS AND ACCESSIBLE LOCATIONS. g. WHERE WORK UNDER THIS CONTRACT REQUIRES EXTENSION, RELOCATION, RECONNECTIONS OR MODIFICATIONS TO EXISTING EQUIPMENT OR SYSTEMS, THE EXISTING EQUIPMENT OR SYSTEM SHALL BE RESTORED TO ITS ORIGINAL AND OPERATING CONDITION. EXTEND NEW HOMERUNS OR CIRCUIT EXTENSIONS, WHERE REQUIRED. DISCONNECT AND REMOVE ALL EQUIPMENT INDICATED TO BE DEMOLISHED, INCLUDING OUTLETS, DEVICES, RELAYS, AND CONDUCTORS. CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 MAINTAIN ELECTRICAL WORKING SPACE CLEARANCE PER NEC 110.26 No. Description Date HOMERUN SPECIFICATION PHASE CONDUCTORS HOME RUN TO PANEL-ARROWHEADS INDICATE CIRCUITS. WIRE INDICATED ARE NEUTRAL AND THREE HOT LEGS (A DIFFERENT PHASE FOR EACH CIRCUIT) MAXIMUM THREE CIRCUITS PER CONDUIT. ALL CIRCUITRY SHALL ALSO CONTAIN AN INSULATED GROUNDING CONDUCTOR (GROUND TICK MARK). WHEN A SINGLE GROUND, NEUTRAL AND PHASE CONDUCTOR (SINGLE PHASE L-N CIRCUITS) ARE INSTALLED. MINIMUM CONDUCTORS SHALL BE #12 AWG IN 3/4"C UON DISCONNECT SWITCHES SUFFIXES AND SPECIFICATION Revisions Drawing Title ELECTRICAL NOTES AND SYMBOLS Phase CONCEPT 35% 60% 90% 100% NEUTRAL A/E Project Number VFD = VARIABLE FREQUENCY DRIVER WP NEMA XX = = WEATHER PROOF NEMA 3R, NEMA 4, OR NEMA 12 SPECIFIC NEMA CONFIGURATION XXXAF XXXAT = FRAME SIZE TRIP SIZE 12-0009.015 GROUNDING Date Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet 1:1 Number E001 # SCALE: 1-1/2" = 1'-0" 2. NEW 120V, 1ø LED FLOOD LIGHT. CONNECT TO NEAREST AVAILABLE SINGLE POLE CIRCUIT ON PANEL OL. FIXTURE TO BE MOUNTED 20'-0" A.F.F. COORDINATE INSTALLATION OF FIXTURE CENTERED ON BARN ABOVE EXTERIOR BUILDING MOULDINGS. COORDINATE WITH OWNER PRIOR TO INSTALLATION. CONTRACTOR SHALL ID NEAREST AVAILABLE CIRCUIT. 4. NEW PHOTOCELL TIED TO NEW EXTERIOR FIXTURES AND TIE TO NEW TIMECLOCK. 5. NEW 365/7 DAY ELECTRONIC PROGRAMMABLE TIMECLOCK. 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 0 SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' SCALE: 1" = 1'-0" 1' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 2' 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 3. NEW 120V, 1ø LED WALLPACK LIGHT FIXTURES. REUSE EXISTING WIRING AND CONNECT TO EXISTING CIRCUIT. 2' 0 1' 1. NEW 120V, 1ø LED POLE LIGHT FIXTURE MOUNTED 15' A.F.F. CONNECT TO NEAREST AVAILABLE SINGLE POLE CIRCUIT ON PANEL OL. CONTRACTOR SHALL ID NEAREST AVAILABLE CIRCUIT. 3 3 H SCALE: 1/2" = 1'-0" UP UP SCALE: 1/4" = 1'-0" 0 UP 4 4 5 G 1 TC 12' F SCALE: 3/16" = 1'-0" 8' 4' PC PC 2 No. Description Date 16' 0 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 18' - 5 1/2" 2' 4' 8' 0 1' 2' 4' H SCALE: 1/8" = 1'-0" 0 4' 8' PROPERTY LINE Revisions 1 E101 SITE PLAN - ELECTRICAL Drawing Title SCOPE OF WORK ELECTRICAL SITE PLAN 1/16" = 1'-0" Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' KEY NOTES S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model 1:1 Drawn By Author Checked By Checker Sheet E 100% Number E101 SCALE: 1-1/2" = 1'-0" 1' 2' 2 EDL101 2 EP101 2' 0 2 EL101 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 SCALE: 1" = 1'-0" KITCHEN 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 1/2" = 1'-0" MAIN LOBBY 0 8' 0 1' 2' 4' SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' 1 2' 0 1/2' 1' 2 EDP101 SCALE: 1/4" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 SCALE: 3/16" = 1'-0" No. STORAGE 4 2 1 EDL101 OFFICE 1 EP101 1 EDP101 Revisions Drawing Title SCOPE OF WORK ELECTRICAL FIRST FLOOR OVERALL PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date 1 EL101 CONFERENCE SCALE: 1/8" = 1'-0" 8' 4' 0 Description OFFICE 16' 0 4' 8' 12' 0 2' 4' 10 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION 1 E102 ELECTRICAL FIRST FLOOR OVERALL PLAN 3/16" = 1'-0" S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet E 100% 1:1 Number E102 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' SCALE: 1" = 1'-0" 1' 3' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" DN DANCE STUDIO TEEN ROOM 9 E SCALE: 1/2" = 1'-0" SCALE: 1/4" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 SCALE: 3/16" = 1'-0" No. F 1 EDL102 Revisions Drawing Title SCOPE OF WORK ELECTRICAL SECOND FLOOR OVERALL PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date ROOM F SCALE: 1/8" = 1'-0" 8' 4' 0 Description 1 EL102 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 1' 2' 0 1/2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION 1 E103 ELECTRICAL SECOND FLOOR OVERALL PLAN S 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By JO Checked By AM 1:1 3/16" = 1'-0" Sheet E W N Number E103 SCALE: 1-1/2" = 1'-0" 2' 1' 0 LOAD "a" LOCAL ON/OFF SWITCH(S) LOCATE AS INDICATED ON DRAWINGS RED NEUTRAL PHASE S 3a S 3a 2' 120V OR 277V, SINGLE PHASE OCCUPANCY 1' SCALE: 1" = 1'-0" NTS 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 24" 4' 0 SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' E501 LINE VOLTAGE CEILING MOUNTED OCCUPANCY SENSOR WIRING DIAGRAM WITH THREE WAY SWITCHES. 2' 0 1/2' 1 CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 SENSOR SCALE: 1/2" = 1'-0" 12" BASE PLATE AND BOLTS PER LIGHT POLE MANUFACTURER LUMINAIRE POST AND BASE AS PER LIGHTING VENDOR. REFER TO DETAIL #1 ON THIS SHEET. SLOPE TOP AWAY FROM POLE 24"x24" CONC. PIER FOR LIGHT POLE 8' 0 1' 2' EQ. 5' MIN. SCALE: 1/4" = 1'-0" 6 - #6 VERT 12' 0 2' 4' #3 TIE @12" MAX SCALE: 3/16" = 1'-0" 2 E501 LUMINAIRE POST BASE DETAIL Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 No. Description Date 1 : 20 SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 24"x24" Revisions Drawing Title ELECTRICAL DETAILS Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED NEUTRAL 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet 1:1 Number E501 1. REMOVE ALL EXISTING WIRING WITHIN WORK AREA BACK TO SOURCE. FEEDERS SERVING PANEL K AND A ARE TO BE REUSED. DEMOLITION KEY NOTES 2. EXISTING 2'x4' LIGHT FIXTURE IS TO BE DEMOLISHED. 3. EXISTING 2'x2' LIGHT FIXTURE IS TO BE DEMOLISHED. 1 1 5. EXISTING CIELING FAN IS TO BE REMOVED. 6. EXISTING 1'x4' SURFACE MOUNTED LIGHT FIXTURE IS TO BE REMOVED. 7. EXISTING EMERGENCY WALL PACK LIGHT FIXTURE IS TO BE REMOVED. 2' SD 1 8. EXISTING LIGHT FIXTURES IN THE LOADING DOCK ARE TO BE REMOVED. RETAIN WIRING FOR REUSE. SCALE: 1" = 1'-0" 2 1' CASEY COMMUNITY CENTER INTERIOR RENOVATION 4. EXISTING ROUND SURFACE MOUNTED LIGHT FIXTURE IS TO BE REMOVED. 3 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 1 SD 3' 0 1/2' # 1. EXISTING LIGHT SWITCH IS TO BE DEMOLISHED. 4 SCALE: 1-1/2" = 1'-0" 0 1' 1 NIKA A+E 5 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" 2' 1' 0 4' 1 APARTMENT AND BATHROOM ELECTRICAL REFLECETED CEILING PLAN - ENLARGED DEMOLITION SCALE: 1/2" = 1'-0" 3/8" = 1'-0" SCALE: 1/4" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 1 12' 0 2' 4' 8' 0 1' 2' EDL101 LOADING DOCK SCALE: 3/16" = 1'-0" 1B No. 6 KITCHEN 1 SCALE: 1/8" = 1'-0" 8' 4' 6 6 6 Revisions 6 6 Drawing Title SCOPE OF WORK ELECTRICAL FIRST FLOOR ENLARGED REFLECTED CEILING PLAN - DEMOLITION 7 Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date 6 6 0 Description 8 16' 0 4' 8' 1 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL SHEET NOTES S 2 EDL101 ELECTRICAL FIRST FLOOR ENLARGED REFLECETED CEILING PLAN - DEMOLITION 3/8" = 1'-0" 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 Drawn By JO Checked By AM Sheet E W N CADD Plot Scale Revit Model 1:1 Number EDL101 1. RETAIN ALL EXISTING WIRING FOR REUSE. # SCALE: 1-1/2" = 1'-0" 1. EXISTING 2'x4' TROFFER LIGHT FIXTURE IS TO BE REMOVED. 2. EXISTING LIGHT SWITCH IS TO BE REMOVED. 3. EXISTING EXIT SIGN LIGHT FIXTURE IS TO BE REMOVED. CASEY COMMUNITY CENTER INTERIOR RENOVATION 4. EXISTING EMERGENCY WALL PACK LIGHT FIXTURE IS TO BE REMOVED. 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 SCALE: 1" = 1'-0" 0 1/2' 1' 2' 0 1' DEMOLITION KEY NOTES 3' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" 4 3 ROOM F F 1 1 1 1 1 1 4' 0 1' NIKA A+E 2' 2 2 1 1 1 SCALE: 1/2" = 1'-0" 1 1 2 SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' 1 1 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 ELECTRICAL SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - COMPUTER ROOM F DEMOLITION 3/8" = 1'-0" SCALE: 3/16" = 1'-0" No. Description Date SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' EDL102 Revisions Drawing Title SCOPE OF WORK ELECTRICAL SECOND FLOOR ENLARGED RCP - COMPUTER ROOM F - DEMOLITION Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL SHEET NOTES S 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 Drawn By JO Checked By AM Sheet E W N CADD Plot Scale Revit Model 1:1 Number EDL102 1. EXISTING BRANCH WIRING FROM THE APARTMENT SHALL BE REMOVED BACK TO PANEL A. 2. RETAIN FEEDERS FOR PANELS A AND K. GFCI R J 1 SCALE: 1-1/2" = 1'-0" 0 DEMOLITION KEY NOTES 1 1 W TOILET 1 2. EXISTING TELEPHONE AND DATA OUTLETS ARE TO BE REMOVED. PANEL OL (ETR) EF 5. EXISTING EXHAUST FAN IS TO BE REMOVED. 6. EXISTING SWITCH FOR EXHAUST FAN IS TO BE REMOVED. 3 PANEL B (ETR) 2' 1 7. EXISTING 120/208V, 3ø, 400A PANELBOARD K IS TO BE REMOVED. 8. EXISTING ICE MACHINE IS TO BE REMOVED. 9. EXISTING DISH WASHER IS TO BE REMOVED. SCALE: 1" = 1'-0" APARTMENT 1' 4. EXISTING HOOD IS TO BE REMOVED. A 1 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 10. EXISTING JUNCTION BOX IS TO BE REMOVED. CONTRACTOR SHALL CONTACT OWNER PRIOR TO REMOVAL. 2 1 11. EXISTING WALL MOUNTED AC UNITS ARE TO BE REMOVED. 12. EXISTING RANGE, REFRIGERATOR, AND FREEZER RECEPTACLE ARE TO REMAIN. 1 1 3' 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 3. EXISTING 120/208V, 3ø, 100A PANELBOARD A IS TO BE REMOVED. 6 J 2 # 1. EXISTING RECEPTACLES ARE TO BE REMOVED. 3 5 REF 1' 4 NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1 SCALE: 3/4" = 1'-0" 1 AC 1 1 11 11 AC J J 4' 0 1' 2' 1 SCALE: 1/2" = 1'-0" EDP101 APARTMENT AND BATHROOM ELECTRICAL PLAN - ENLARGED - DEMOLITION 3/8" = 1'-0" SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' 1 12 12 REF 12 FRZ J 12' 4 SCALE: 3/16" = 1'-0" 8' 4' 0 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 7 R No. LOADING DOCK Description Date 1B 9 8 J 16' J KITCHEN 1 SCALE: 1/8" = 1'-0" 0 4' 8' J Revisions 10 Drawing Title SCOPE OF WORK 1 ELECTRICAL FIRST FLOOR ENLARGED PLANS DEMOLITION 10 1 Phase CONCEPT 32' A/E Project Number SCALE: 1/16" = 1'-0" 16' Date 8' 35% 60% 90% 100% J 12-0009.015 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL SHEET NOTES S 2 EDP101 KITCHEN ELECTRICAL PLAN - ENLARGED - DEMOLITION 3/8" = 1'-0" Drawing Scale: AS NOTED CADD Filename 07-15-15 Drawn By JO Checked By AM Sheet E W N CADD Plot Scale Revit Model 1:1 Number EDP101 # 1. NEW 3 WAY LIGHT SWITCHES. TIE TO OCCUPANCY SENSOR. 2. NEW 2'x4' DIRECT/INDIRRECT TROFFER LIGHT FIXTURE. 3. NEW LENSED 2'x4' LIGHT FIXTURE. A-11 9 7 4. NEW SINGLE POLE LIGHT SWITCH. TIE TO OCCUPANCY SENSOR. 5. NEW EMERGENCY WALL PACK/SIGN COMBO LIGHT FIXTURE. E SCALE: 1-1/2" = 1'-0" 0 1' D 8 6. NEW CEILING MOUNTED OCCUPANCY SENSOR. 7. NEW CEILING MOUNTED LED EXIT SIGN. 4 2 CASEY COMMUNITY CENTER INTERIOR RENOVATION 8. NEW 2'X2' DIRECT/INDIRECT LIGHT FIXTURE. D 9. NEW LIGHT SWITCH WITH DIMMER. 10 A 10. NEW SINGLE POLE LIGHT SWITCH WITH OCCUPANCY SENSOR. OS 2' 11. TIE TO EXISTING LOADING DOCK LIGHT CIRCUIT. 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 2 SCALE: 1" = 1'-0" 2 A OS 2 A 2 6 6 OS 3' 0 1/2' 1' A-9 NIKA A+E 2 SCALE: 3/4" = 1'-0" 2' 1' A 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com A 4 CONFERENCE 2 4' 0 2 STORAGE 1 APARTMENT ELECTRICAL REFLECTED CEILING PLAN - ENLARGED - PROPOSED SCALE: 1/2" = 1'-0" 3/8" = 1'-0" SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' EL101 11 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 11 3 12' 3 LOADING DOCK 3 B 16' KITCHEN 3 B OS SCALE: 1/8" = 1'-0" 8' 4' 11 11 3 B 3 3 3 B 3 B Revisions Drawing Title SCOPE OF WORK ELECTRICAL FIRST FLOOR ENLARGED REFLECTED CEILING PLAN Phase B 5 CONCEPT C A/E Project Number 3 SCALE: 1/16" = 1'-0" 8' 16' 12-0009.015 Date 1 S 2 EL101 KITCHEN ELECTRICAL REFLECTED CEILING PLAN - ENLARGED - PROPOSED 3/8" = 1'-0" Date 7 K-14 32' Description 6 1 B No. 1B 3 3 B 0 B 1 SCALE: 3/16" = 1'-0" 0 4' 8' B 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' NEW WORK KEY NOTES 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet E 100% 1:1 Number EL101 1. RETAIN ALL EXISTING WIRING FOR REUSE. NEW WORK KEY NOTES # SCALE: 1-1/2" = 1'-0" 0 1' 1. NEW SINGLE POLE LIGHT SWITCH. TIE TO OCCUPANCY SENSOR. 2. NEW 2'x4' TROFFER LIGHT FIXTURE. 3. NEW 2'x4' TROFFER LIGHT FIXTURE WITH EMERGENCY BATTERY. 4. NEW EXIT SIGN LIGHT FIXTURE WITH EMERGENCY BATTERY. 5. REUSE EXISTING WIRING FOR CIRCUIT. WIRING SHOWN MAY NOT REFLECT ACTUAL WIRE CONFIGURATION. 6. NEW CEILING MOUNTED OCCUPANCY SENSOR. 7. NEW SINGLE POLE LIGHT SWITCH SERVING LIGHT IN THE TELECOMMUNICATIONS ROOM. 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1 SCALE: 3/4" = 1'-0" 0 1' 3' SCALE: 1" = 1'-0" 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 2' 0 1/2' 1' 2' 8. NEW SINGLE POLE LIGHT SWITCH SERVING LIGHT IN THE STORAGE ROOM. CASEY COMMUNITY CENTER INTERIOR RENOVATION NIKA A+E E ROOM F 4 2 F 4' 5 6 6 3 2 A 2 OS A A A SCALE: 1/2" = 1'-0" 0 1' 2' OS 8 6 A A A 2 2 A 2 A OS 3 A SCALE: 1/4" = 1'-0" TELECOMMUNICATIONS ROOM 7 STORAGE ROOM 2 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 12' 0 2' 4' 8' 2 3/8" = 1'-0" SCALE: 3/16" = 1'-0" EL102 ELECTRICAL SECOND FLOOR ENLARGED REFLECTED CEILING PLAN - COMPUTER ROOM F No. Description Date SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 1 Revisions Drawing Title SCOPE OF WORK ELECTRICAL SECOND FLOOR ENLARGED RCP - COMPUTER ROOM F Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL SHEET NOTES S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet E 100% 1:1 Number EL102 SCALE: 1-1/2" = 1'-0" 2' 1' 0 SCALE: 1" = 1'-0" 1' 2' LUMINARIES SCHEDULE LAMP DATA 3' 0 1/2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E FIXTURE TYPE MOUNTING MOUNTING HEIGHT (A.F.F.) VOLTS NOMINAL WATTS TOTAL WATTS LAMPS BULB TYPE TYPE MANUFACTURER CATALOG NO. NOTES SCALE: 3/4" = 1'-0" A 2'x4' RECESSED TROFFER DIRECT/INDIRECT CEILING RECESSED 8'-0" 120 28 56 2 T5 FLUOR PHILIPS LIGHTING B 2' x 4' LENSED ENCLOSED CEILING RECESSED 8'-0" 120 28 56 2 T5 FLUOR PHILIPS LIGHTING 2SPG228-FS01-120 C WALL MOUNTED COMBO EMERGENCY LIGHT 7'-6" 120 2.8 2.8 2 LED LED PHILIPS LIGHTING VCLANGW D 2'x2' RECESSED TROFFER DIRECT/INDIRECT 8'-0" 120 14 28 2 T5 FLUOR PHILIPS LIGHTING 2SPG214R-FS-120 E CEILING EXIT LIGHT 8'-0" 120 4 4 1 LED LED PHILIPS LIGHTING VEGWEM F WALL MOUNTED FLOOD LIGHT 20'-0" 120 52 52 32 LED LED PHILIPS LIGHTING CSFS16L530NWG1SFSP120 G LED POLE LIGHT FREE STANDING 15' 120 77 77 1 LED LED PHILIPS LIGHTING ECF-1-5-75LA-4853-CW-UNV-BLP-PCB H WALLPACK FIXTURE WALL MOUNT EXISTING 120 13.9 13.9 1 LED LED PHILIPS LIGHTING TLW-10LED-4K-PCB-1 2AVG228-PMW-120 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com FOR EMERGENCY FIXTURES, PROVIDE 90 MINUTE BATTERY BACKUP WITH EMERGENCY BALLAST. SCALE: 1/2" = 1'-0" WALL MOUNT CEILING RECESSED CEILING MOUNT SCALE: 1/4" = 1'-0" WALL MOUNT SCALE: 3/16" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 No. Description Date SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 1' 2' TYPE Revisions Drawing Title ELECTRICAL LUMINARE SCHEDULE Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet 1:1 Number EL501 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' SCALE: 1" = 1'-0" 1' SCALE: 1/2" = 1'-0" 2.8 1.4 1.6 1.8 2.1 2.1 2.3 2.5 2.5 2.5 2.7 1.3 1.5 1.6 1.7 1.9 2.1 2.2 2.2 2.2 2.2 1.4 1.3 1.1 1.0 0.7 1.9 1.6 1.4 1.2 1.2 0.8 0.3 0.1 0.0 0.0 3.3 1.9 1.3 1.5 1.5 1.6 1.8 2.0 2.2 2.0 2.1 2.2 1.9 1.6 1.4 1.3 1.2 0.9 0.3 0.1 0.0 0.0 3.7 4.1 4.7 2.3 1.3 1.4 1.5 1.6 1.7 1.9 2.0 1.7 1.9 2.0 1.8 1.6 1.4 1.3 1.3 0.9 0.3 0.1 0.0 0.0 4.1 4.6 5.1 2.0 1.3 1.4 1.5 1.5 1.6 1.7 1.6 1.7 1.6 1.7 1.7 1.5 1.4 1.3 1.3 0.8 0.3 0.1 0.0 0.0 3.6 4.0 4.6 2.3 1.2 1.4 1.4 1.5 1.6 1.8 2.0 1.6 1.8 1.9 1.7 1.5 1.4 1.3 1.2 0.9 0.3 0.1 0.0 0.0 2.5 3.0 3.4 1.9 1.2 1.3 1.3 1.4 1.5 1.7 1.8 1.6 1.7 1.8 1.6 1.4 1.3 1.2 1.2 0.8 0.3 0.1 0.0 0.0 0 SCALE: 1/4" = 1'-0" SCALE: 3/16" = 1'-0" SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' SCALE: 3/4" = 1'-0" 3' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1' 2' 0 1/2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 0.0 0.0 0.0 0.0 0.0 0.0 1.4 1.8 2.1 1.4 1.0 1.2 1.2 1.3 1.5 1.5 1.6 1.5 1.5 1.5 1.5 1.4 1.3 1.2 1.1 0.8 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.8 1.0 1.2 0.9 0.9 1.1 1.1 1.3 1.3 1.4 1.4 1.4 1.4 1.4 1.3 1.3 1.2 1.1 1.0 0.6 0.3 0.1 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.4 0.5 0.7 0.7 0.7 1.0 1.0 1.1 1.1 1.2 1.3 1.3 1.3 1.2 1.2 1.1 1.0 1.0 0.8 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.6 0.8 0.9 1.0 1.1 1.1 1.2 1.2 1.2 1.1 1.1 1.0 0.9 0.9 0.7 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.8 0.9 0.9 1.0 1.0 1.0 1.0 0.9 0.9 0.7 0.6 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.4 0.5 0.5 0.5 0.4 0.5 0.5 0.5 0.4 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 No. Description Drawing Title SCOPE OF WORK 1 EL601 ELECTRICAL LIGHTING CALCULATIONS - SITE ELECTRICAL LIGHTING CALCULATIONS - SITE 1" = 10'-0" Phase 32' A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date Revisions CONCEPT 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet E 100% 1:1 Number EL601 7 W A-2 SCALE: 1-1/2" = 1'-0" +48" +48" A.F.F. 1 NEW 208V, 1ø, 1.5kW ELECTRIC HEATER CUH-1. CUH-1. 3. NEW 11 A-8,10 A-2 NEW 208V, 1ø, .75kW ELECTRIC HEATER CUH-2. CUH-2. 2. NEW A-24 A-24 A. 4. NEW 120/208V, 3ø, 150 150 MAINS MAINS 70A 70A MCB MCB LOAD LOAD CENTER PANELBOARD PANELBOARD A. A-7 A-7 CUH-1 5. NEW 240V, 1ø, 30A 30A DISCONNECT DISCONNECT SWITCH FOR ELECTRIC HEATER HEATER CUH-1 ABOVE ABOVE CEILING. CEILING. 88 A-3 A-3 FRZ 6. NEW TELEPHONE AND DATA DUAL DUAL OUTLET. OUTLET. STORAGE A-1 A-1 4 11 11 44 PANEL OL OL PANEL A-8,10 7 W 11 11 JJ 15 15 M J 11 22 M J A-21,23 A-21,23 A-16,18 A-16,18 9. NEW 220V RECEPTACLE FOR ICE MACHINE. MACHINE. 11 M J 16 16 A-4 A-4 33 A-17,19 A-17,19 A-17,19 A-17,19 SCALE: 1" = 1'-0" 1' 1' 12. NEW 120/208V, 3ø, 350A MCB PANELBOARD PANELBOARD K. K. J 26 26 55 M HOOD 13. NEW 1/2HP, 208V, 3ø, 3ø, 60Hz, 60Hz, EXHAUST EXHAUST FAN EF-1. OPERATION VIA HOOD CONTROLS. EXHAUST EXHAUST FAN FANIS IS TO TO BE BE LOCATED LOCATED ON ON ROOF. ROOF. PROVIDE PROVIDE INTERLOCK INTERLOCK CONTROLS. PER MECHANICAL MECHANICAL SHEET SHEET M601. M601. PER CUH-2 14. NEW 240V, 1ø, 30A 30A DISCONNECT DISCONNECT SWITCH FOR ELECTRIC HEATER CUH-2 ABOVE CEILING. CEILING. PROVIDE PROVIDE INTERLOCK INTERLOCK PER PER MECHANICAL MECHANICAL SHEET SHEET M601. M601. ABOVE A-20,22 A-20,22 CONFERENCE CONFERENCE A-12,14 A-12,14 UNIT FCU-2. FCU-2. 16. NEW 0.23FLA, 208V, 1ø, 1ø, 60Hz 60Hz SPLIT SPLIT SYSTEM SYSTEM HVAC UNIT 66 A-17,19 A-17,19 J 22 J 17. NEW 0.23FLA, 208V, 1ø, 1ø, 60Hz 60Hz SPLIT SPLIT SYSTEM SYSTEM HVAC UNIT UNIT FCU-4. FCU-4. 18 18 14 14 18. NEW 0.23FLA, 208V, 1ø, 1ø, 60Hz 60Hz SPLIT SPLIT SYSTEM SYSTEM HVAC UNIT UNIT FCU-5. FCU-5. 3' 3' A-5 A-5 M J M 11 CTR A-13 A-13 38 38 SCALE: 3/4" = 1'-0" 2' 2' 1' 1' 1 11 J 19. NOT USED. USED. 26 26 A-25,27 A-25,27 20. NEW 30MCA, 208V, 1ø, 1ø, 60Hz 60Hz OUTDOOR OUTDOOR CONDENSING UNIT UNIT CU-1. CU-1. NIKA A+E 21. NEW 20KW, 208V, 3ø, 3ø, 60Hz 60Hz ELECTRIC DUCT HEATER HEATER EDH-1. EDH-1. 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 22. NEW 1.5HP, 208V, 3ø, 60Hz SUPPLY FAN SF-1. PROVIDE INTERLOCK INTERLOCK PER PER MECHANICAL MECHANICAL SHEET SHEETM601. M601. J 14 14 66 36 36 1 22 11 J 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 UNIT FCU-1. FCU-1. 15. NEW 0.28FLA, 208V, 1ø, 1ø, 60Hz 60Hz SPLIT SPLIT SYSTEM SYSTEM HVAC UNIT 22 37 37 11 0 0 10. NEW 220V RECEPTACLE FOR DISH WASHER. WASHER. 11. CONNECT CONNECT FIRE FIRE SUPPRESSION SYSTEM SYSTEM TO TO FIRE FIRE ALARM PANEL. PANEL. 17 17 26 26 26 26 14 14 0 0 1/2' PANEL PANEL B B A-17,19 J 26 26 2' 2' A-6 A-6 PANEL PANEL A 32 32 CASEY COMMUNITY CENTER INTERIOR RENOVATION 7. NEW NEW 220V RECEPTACLE RECEPTACLE FOR FOR DRYER. DRYER. 8. NEW SIMPLEX RECEPTACLE FOR REFRIGERATOR REFRIGERATOR AND AND FREEZER. FREEZER. MTD MTD 60" 60" A.F.F. A.F.F. CTR 1' 1' REF 0 0 1 GFCI GFCI 88 ## DUPLEX RECEPTACLES. RECEPTACLES. 1. NEW 125V WALL MOUNTED MOUNTED DUPLEX 11 CTR 23. NEW 1/6HP, 208V, 1ø, 1ø, 60Hz, 60Hz, EXHAUST EXHAUST FAN EF-2. OPERATION VIA DISHWASHER DISHWASHER CONTROLS. CONTROLS. PROVIDE PROVIDE INTERLOCK PER MECHANICAL MECHANICAL SHEET M601. WP WP WP K-24,26 K-24,26 EXHAUST FAN FAN EF-1 EF-1 TO TO BE BE PROVIDED PROVIDED WITH 24. NEW MOTOR SWITCH FOR EXHAUST EQUIPMENT. EQUIPMENT. 35 35 K-27,29 K-27,29 31 31 USED. 25. NOT USED. 26. NEW MOTOR RATED SWITCH FOR THE THE FAN FAN COIL COIL UNITS. UNITS. 20 20 27. NEW MOTOR RATED SWITCH FOR DISHWASHER DISHWASHER EXHAUST EXHAUST FAN FAN EF-2. EF-2. 34 34 4' 4' 28. NEW 240V, 3ø, 100A 100A NON-FUSED NON-FUSED DISCONNECT SWITCH SWITCH FOR FOR ELECTRIC ELECTRIC DUCT DUCT HEATER HEATER EDH-1. EDH-1. SCALE: 1/2" = 1'-0" 1 EP101 EP101 APATRMENT APATRMENT ELECTRICAL ELECTRICAL PLAN PLAN -- PROPOSED PROPOSED 30. NEW MOTORIZED DAMPER DAMPER 3/8" == 1'-0" 1'-0" 3/8" 31. NEW 240V, 3ø, 60A FRAME, 40A FUSED DISCONNECT SWITCH SWITCH FOR FOR CONDENSING CONDENSING UNIT UNIT CU-1. CU-1. 32. NEW 0.23FLA, 208V, 1ø, 1ø, 60Hz 60Hz SPLIT SPLIT SYSTEM SYSTEM HVAC UNIT UNIT FCU-3. FCU-3. 33. CONNECT CONNECT EXISTING EXISTING RANGE, RANGE, REFRIGERATOR, REFRIGERATOR, AND AND FREEZER FREEZER RECEPTACLES RECEPTACLES TO TO NEW NEW PANELBOARD PANELBOARD K. K. UNIT CU-2. CU-2. 34. NEW 29MCA, 208V, 1ø, 1ø, 60Hz 60Hz OUTDOOR OUTDOOR CONDENSING UNIT SWITCH FOR FOR 35. NEW 240V, 3ø, 60A FRAME, 40A FUSED DISCONNECT SWITCH CONDENSING CONDENSING UNIT UNIT CU-2. CU-2. 8' 8' 0 0 1' 1' 2' 2' 29. NEW MOTOR RATED RATED SWITCH SWITCH FOR FOR SUPPLY SUPPLY FAN FAN SF-1. SF-1. 23 23 PROVIDE 36. NEW 120V, 1ø, 60Hz, 0.7kW OPEN COIL DUCT HEATER. HEATER. PROVIDE INTERLOCK INTERLOCK PER PER MECHANICAL MECHANICAL SHEET SHEET M601. M601. JJ SCALE: 1/4" = 1'-0" 0 0 2' 2' 4' 4' K-11,13 K-11,13 12 12 27 27 38. NEW JUNCTION BOX WITH 3/4" CONDUIT TO PANEL PANEL "A" "A" ABOVE ABOVE CEILING CEILING FOR FUTURE FUTURE TV TV PROJECTOR. PROJECTOR. PROVIDE PROVIDE PULL PULL STRING STRING IN CONDUIT. CONDUIT. PANEL PANEL K K K-21,23,25 K-21,23,25 K-4 K-4 K-6 K-6 33 33 24 24 R REF REF FRZ 12' 12' J J M 33 33 33 33 LOADING LOADING DOCK DOCK 1B SCALE: 3/16" = 1'-0" 0 0 4' 4' 8' 8' 13 13 K-5,7,9 K-5,7,9 11 16' 16' M J K-22 K-22 Revisions 30 30 Drawing Title SCOPE OF WORK 11 CTR CTR J K-16,18,20 K-16,18,20 CTR CTR K-2 K-2 JJ K-15,17,19 K-15,17,19 11 K-1 K-1 SCALE: 1/8" = 1'-0" 22 22 KITCHEN KITCHEN 1 11 ELECTRICAL FIRST FLOOR ENLARGED PLANS 10 10 11 32' 32' GFCI CTR CTR GFCI CTR CTR GFCI GFCI K-3 K-3 SCALE: 1/16" = 1'-0" 16' 16' Date 29 29 Phase DW CONCEPT A/E Project Number K-8,10,12 12-0009.015 Date 8' 8' Description 21 21 GFCI 8' 8' 28 28 IM GFCI 4' 4' No. 99 CTR CTR 0 Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 37. NEW 208V, 1ø, 60Hz, 1.35A ENERGY RECOVERY UNIT. UNIT. PROVIDE PROVIDE INTERLOCK INTERLOCK PER PER MECHANICAL MECHANICAL SHEET SHEET M601. M601. M 11 11 0 0 IF IF THIS THIS DRAWING DRAWING IS IS A A REPRODUCTION, REPRODUCTION, GRAPHIC GRAPHIC SCALE SCALE MUST MUST BE BE USED USED 2' 2' NEW NEW WORK WORK KEY KEY NOTES NOTES S S 22 EP101 EP101 KITCHEN KITCHEN ELECTRICAL ELECTRICAL PLAN PLAN -- PROPOSED PROPOSED 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W W 3/8" 3/8" == 1'-0" 1'-0" N N CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet E E 100% 1:1 Number EP101 1. CONNECT EXISTING 3#3AWG + #8G FEEDERS TO PANEL A. 2. CONNECT EXISTING 2 SETS 4#3/0AWG + #3G FEEDERS TO PANEL K. SCALE: 1-1/2" = 1'-0" 2. NEW 120/208V, 400A PANELBOARD K. CONNECT EXISTING 2 SETS OF #3/0 FEEDERS TO PANEL K. COORDINATE WALL DIMEMSIONS WITH THE NEW PANEL PRIOR TO PURCHASING. 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 60A 3ø 1 2 EMERGENCY PANEL SCALE: 1/2" = 1'-0" 0 1' 2' 4' 0 SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' SCALE: 1" = 1'-0" 1' CASEY COMMUNITY CENTER INTERIOR RENOVATION 2' 0 1/2' # 1. NEW 120/208V, 100A MAINS, 70A MCB, PANELBOARD A. CONNECT EXISTING #3AWG FEEDERS TO PANEL A. COORDINATE WALL DIMENSION WITH THE NEW PANEL PRIOR TO ORDERING. 2' 0 1' NEW WORK KEY NOTES 100 3 Ø, 4 W MLO 1 MDP PANEL M PANEL B PANEL OL PANEL G PANEL A PANEL K PANEL F CT A 120 / 208 V A 1200 M 120 / 208 V 3 Ø, 4 W MLO 400 A 120 / 208 V 3 Ø, 4 MLO W 400 A 120 / 208 V 3 Ø, 4 MLO W 60 A 120 / 208 V 3 Ø, 4 MLO W 225 A 120 / 208 V 3 Ø, 4 MLO W 100 A 120 / 208 V 3 Ø, 4 W 70A MCB 400 A 120 / 208 V 3 Ø, 4 W 350A MCB 100 A 120 / 208 V 3 Ø, 4 W MLO ELECTRICAL RISER DIAGRAM 1/8" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 3/16" = 1'-0" Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 No. Description Date SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' EP501 Revisions Drawing Title ELECTRICAL RISER DIAGRAM Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL SHEET NOTES 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet 1:1 Number EP501 2' SCALE: 1-1/2" = 1'-0" SCALE: 1" = 1'-0" 3' 0 1/2' 1' 2' 0 1' Location: Supply From: Mounting: Enclosure: Branch Panel: K Mechanical Room Panel B Recessed Type 1 Volts: 120/208 Wye Phases: 3 Wires: 4 10kA MCB 150 A 70 A Location: Supply From: Mounting: Enclosure: SCALE: 3/4" = 1'-0" KITCHEN MDP Recessed Type 1 Volts: 120/208 Wye Phases: 3 Wires: 4 A.I.C. Rating: 10kA Mains Type: MLO Mains Rating: 400 A Notes: CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Circuit Description RECEPTACLE - MULTIPURPOSE ROOM REFRIGERATOR - MULTIPURPOSE ROOM RECEPTACLE - CONFERENCE ROOM GFCI RECEPTACLE - BATHROOM LIGHTING - MULTIPURPOSE ROOM LIGHTING - CONFERENCE ROOM OPEN COIL DUCT HEATER - PH-1 Trip Poles A 15 A 1 1080 VA 656 VA 20 A 1 15 A 1 20 A 1 180 VA 2080 VA 15 A 1 15 A 1 20 A 1 700 VA 325 VA FCU-1, 2, 3, 4, 5 -ELECTRIC HEATER - CUH-2 -ELECTRIC HEATER - CUH-2 -- 20 A -15 A -15 A -- B 1265 VA 160 VA C 540 VA 540 VA 360 VA 464 VA 325 VA 145 VA 750 VA 2080 VA 750 VA 2 -2 -2 -- 145 VA 375 VA 375 VA 375 VA 375 VA 1200 VA Poles 1 1 1 2 -2 -2 -2 -1 Trip 20 A 15 A 15 A 30 A -15 A -15 A -15 A -15 A Circuit Description REFRIGERATOR - MULTIPURPOSE ROOM RECEPTACLE - CONFERENCE ROOM RECEPTACLE - CONFERENCE ROOM WASHING MACHINE -ENERGY RECOVERY UNIT - ERU-1 -ELECTRIC HEATER - CUH-1 -ELECTRIC HEATER - CUH-2 -MICROWAVE - RECEPTACLE 375 VA 375 VA 5916 VA 52 A 5920 VA 52 A CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Circuit Description RECEPTACLE - KITCHEN RECEPTACLE - KITCHEN ICE MACHINE --HOOD EF-1 & DISHWASHER EF-2 -ELECTRIC Duct Heater - EDH-1 --RANGE --OUTDOOR CONDENSING UNIT - CU-2 -- 4159 VA 35 A Trip Poles A 20 A 1 1500 VA 1500 VA 20 A 1 20 A 3 --- 1165 VA 5404 VA --20 A 2 --- 1014 VA 964 VA 70 A 3 ----- 6667 VA 990 VA 70 A 3 ----- 8406 VA 3900 VA 40 A 2 --- 31509 VA 266 A Total Load: Total Amps: Legend: 2' 1' 0 A.I.C. Rating: Mains Type: Mains Rating: MCB: Notes: Total Load: Total Amps: B C 1500 VA 656 VA 1165 VA 1265 VA 1165 VA 5404 VA 1014 VA 5404 VA 6667 VA 990 VA 6667 VA 990 VA 8406 VA 500 VA 8406 VA 3900 VA Poles 1 1 1 3 --1 3 --1 2 -- Trip 20 A 20 A 20 A 50 A --15 A 20 A --20 A 40 A -- Circuit Description RECEPTACLE - KITCHEN REFRIGERATOR FREEZER DISH WASHER --Lighting - KITCHEN SUPPLY FAN - SF-1 --MOTORIZED DAMPER OUTDOOR CONDENSING UNIT - CU-1 -- 3770 VA 3770 VA 29057 VA 242 A 32580 VA 275 A Load Classification Power Motor Largest Motor Connected Load 5100 VA 232 VA 58 VA Demand Factor 100.00% 100.00% 125.00% Estimated Demand 5100 VA 232 VA 73 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: Load Classification Power Motor Largest Motor 15995 VA 16009 VA 44 A 44 A Connected Load 25498 VA 7540 VA 7800 VA Demand Factor 100.00% 100.00% 125.00% CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com Legend: Estimated Demand 25498 VA 7540 VA 9750 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 93146 VA 95096 VA 259 A 264 A Notes: SCALE: 1/2" = 1'-0" Branch Panel: B Location: Supply From: Mounting: Enclosure: 8' 0 1' 2' 4' Notes: WIRE SCHEDULE ELETRIC ROOM MDP Surface Type 1 Volts: 120/208 Wye Phases: 3 Wires: 4 A.I.C. Rating: 10kA Mains Type: MLO Mains Rating: 400 A MCB Rating: BREAKER SIZE SCALE: 1/4" = 1'-0" SCALE: 3/16" = 1'-0" SCALE: 1/8" = 1'-0" CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 Circuit Description Space HVAC MECH ROOM 2 --STAIRWELL STORAGE HEATER --OUTSIDE UNIT HVAC --ELEVATOR ROOM FAN ELEVATOR ROOM LIGHTS AUTO DOOR OPENERS ELEVATOR CAB LIGHTS AIR CURTAIN --SCREEN PROJECTORS *PANEL A --PANEL D --- Trip Poles A B C Poles Trip Circuit Description --0 VA 20 A 3 360 VA --360 VA --360 VA 60 A 3 3600 VA 0 VA --- Space --3600 VA 2400 VA 3 20 A HVAC MECH ROOM 1 --- 3600 VA 2400 VA --- -60 A 3 3600 VA 2400 VA --- ---3600 VA 1080 VA 1 20 A RECPT SNACK/ RECPT ROOM A --- 3600 VA 1080 VA 1 20 A LOAD 20 A 1 500 VA 1200 VA 1 20 A LIGHTS LOBBY 20 A 1 500 VA 1080 VA 1 20 A RECPT 20 A 1 500 VA 1080 VA 1 20 A RECPT 20 A 1 500 VA 750 VA 2 20 A ELEVATOR ROOM HEATER 50 A 3 3000 VA 750 VA --- ---- 3000 VA 667 VA 3 20 A OUTSIDE HVAC UNIT --3000 VA 667 VA --- -20 A 1 500 VA 667 VA --- -70 A 3 6125 VA 2592 VA 3 100 A PANEL G --6125 VA 2592 VA --- ---6125 VA 2592 VA --- -200 A 3 12000... 5712 VA 3 175 A ELEVATOR --12000 VA 5712 VA --- ---12000 VA 5712 VA --- -Total Load: Total Amps: 42716 VA 356 A 43006 VA 359 A CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 WIRE SIZE RATING 20 12AWG 25 1 12AWG 3/4" C 30 10AWG 35 1 10AWG 3/4" C 40 8AWG 50 1 10AWG 3/4" C 50 8AWG 50 1 10AWG 1" C 70 4AWG 85 1 8AWG 1" C 100 3AWG 100 1 8AWG 1-1/2" C SETS GROUND SIZE RACEWAY SIZE REMARKS Professional Certification. I certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 45772, Expiration date 07.28.2016 *ALL WIRES SHALL BE THWN, 75C, COPPER No. Description Revisions 43966 VA 367 A Drawing Title Load Classification Power Motor Connected Load 129687 VA 0 VA Demand Factor 100.00% 0.00% Estimated Demand 129687 VA 0 VA ELECTRICAL PANEL SCHEDULES Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 129687 VA 129687 VA 360 A 360 A Phase CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 16' Date 8' Date Legend: 32' 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' Notes: 2#3/0AWG 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED Branch Panel: A Notes: CIRCUIT DESCRIPTION WITH " * " NEXT TO DESCRIPTION HAVE A REVISED LOAD 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By JO Checked By AM Sheet 1:1 Number EP601 GENERAL NOTES MECHANICAL ABBREVIATIONS MECHANICAL SYMBOLS AND ABBREVIATIONS ABBR. SYMBOL REMARKS TYPE HORIZONTALLY MOUNTED EXHAUST/RETURN AIR REGISTER/GRILLE CFM TYPE VERTICALLY MOUNTED EXHAUST/RETURN AIR REGISTER/GRILLE CFM TYPE HORIZONTALLY MOUNTED SUPPLY AIR DIFFUSER/REGISTER/GRILLE CFM TYPE VD SA RA EA OA * SA * RA * RA * EA * EA * OA * OA 24X12 BRITISH THERMAL UNITS PER HOUR CFM CUBIC FEET PER MINUTE CUH CABINET UNIT HEATER CU CONDENSING UNIT DIA DIAMETER SYMBOL INSTALL COMPLETE AND OPERATE MECHANICAL SYSTEMS AS INDICATED ON THE REMARKS DISCONNECT FROM EXISTING DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE. 2. DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT NECESSARILY SHOW ALL EXISTING COMPONENTS. COORDINATE INSTALLATION OF NEW EQUIPMENT AND CONNECTION TO EXISTING ACCESSORIES WITH EXISTING CONDITIONS. MINOR MODIFICATIONS TO EXISTING COMPONENTS, AT NO ADDITIONAL COST TO THE GOVERNMENT, MAY BE REQUIRED AS TO PROVIDE A COMPLETE AND CODE COMPLIANT SYSTEM. 3. THE GENERAL CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL EXISTING TO FCU FAN COIL UNIT EA EXHAUST AIR RECTANGULAR DUCTWORK SUPPLY/OUTSIDE AIR ELBOW UP EDH ELECTRIC DUCT HEATER EF EXHAUST FAN CONTRACTOR BEGIN FABRICATION AND/OR INSTALLATION OF ANY EQUIPMENT/ RECTANGULAR DUCTWORK SUPPLY/OUTSIDE AIR ELBOW DOWN EG EXHAUST GRILLE DUCTWORK/ PIPING/ ELECTRICAL/ SPRINKLER/ CABLE TRAYS PRIOR TO ERU ENERGY RECOVERY UNIT RECEIVING APPROVED COORDINATION DRAWINGS FROM GOVERNMENT. RECTANGULAR DUCTWORK EXHAUST/RETURN/RELIEF AIR ELBOW UP (E) EXISTING F DEGREE FAHRENHEIT RECTANGULAR DUCTWORK EXHAUST/RETURN/RELIEF AIR ELBOW DOWN FLA FULL LOAD AMPS FN FURNACE HP HORSEPOWER HZ HERTZ IN INCH IU INDOOR UNIT KW KILOWATT LBS POUNDS SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE MCA MINIMUM CURRENT AMPACITY APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST REMAIN AND NEW EQUIPMENT, DUCTWORK, HVAC PIPING, PLUMBING PIPING, SPRINKLER PIPING, ELECTRICAL CONDUITS, CABLE TRAYS ETC WITH RESPECTIVE TRADES PRIOR TO DEVELOPING COORDINATION DRAWINGS AND SUBMITTING THEM FOR GOVERNMENT REVIEW AND APPROVAL. UNDER NO CIRCUMSTANCES SHALL THE 4. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS AND APPLICABLE CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 CODES AND REGULATIONS. 5. PROVIDE VIBRATION ISOLATORS FOR ALL PIPING SUPPORTS CONNECTED TO, AND WITHIN 50 FT. OF ISOLATED EQUIPMENT THROUGHOUT THE MECHANICAL ROOMS. 6. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, CIVIL, ELECTRICAL WORK, ETC., SHOWN ON OTHER DRAWINGS. SUPPLY AIR ( * DUCT SIZE ) RETURN AIR ( * DUCT SIZE ) EXHAUST AIR ( * DUCT SIZE ) OUTSIDE AIR ( * DUCT SIZE ) DEMOLITION 24"Ø BTUH ABBR. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO DOWN VOLUME DAMPER * SA REMARKS 1. DN VERTICALLY MOUNTED SUPPLY AIR DIFFUSER/REGISTER/GRILLE CFM ABBR. MECHANICAL SYMBOLS AND ABBREVIATIONS ROUND DUCT SIZE RECTANGULAR DUCT SIZE, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN 7. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. 8. MOCP MAXIMUM OVERCURRENT PROTECTION CONDITIONS AND RESULT MUST BE DETERMINED BY THE PROJECT SITE NC NOISE CRITERION CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING OA OUTSIDE AIR INSTALLED. DO NOT SCALE DRAWINGS. PH PHASE/ PENTHOUSE PVC POLYVINYL CHLORIDE R RADIUS RA RETURN AIR RAD RETURN AIR DUCT RPM REVOLUTION PER MINUTE SA SUPPLY AIR SAD SUPPLY AIR DUCT SD SUPPLY DIFFUSER FALL AND INJURE BUILDING OCCUPANTS. DESIGN ALL EQUIPMENT MOUNTINGS TO SF SUPPLY FAN RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY HORIZONTAL SG SUPPLY GRILLE DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION. TG TRANSFER GRILLE (TYP) TYPICAL V VOLT W WIDTH 9. NIKA A+E LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com LOCATIONS AND SIZES OF ALL FLOOR, AND WALL OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 10. ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK, PIPING, CONDUIT, ETC SHALL BE FIRE STOPPED/BLOCKED WITH AN APPROVED PRODUCT. 11. PROVIDE LAMINATED SHEET IN BINDERS FOR EACH EQUIPMENT SYSTEM CONTROL DIAGRAM AND SEQUENCE OF OPERATION FOR USE BY FACILITY MAINTENANCE STAFF. 12. MOUNT ALL OVERHEAD UTILITIES AND OTHER FIXTURES WEIGHING 31 POUNDS OR MORE (EXCLUDING DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS THAT COLLECTIVELY EXCEED THAT WEIGHT) TO MINIMIZE THE LIKELIHOOD THAT THEY WILL THIS STANDARD DOES NOT PRECLUDE THE NEED TO DESIGN EQUIPMENT MOUNTINGS FOR FORCES REQUIRED BY OTHER CRITERIA SUCH AS SEISMIC STANDARDS. 13. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING AND EQUIPMENT INSTALLATION. 14. LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, CONTROLS AND VALVING. 15. REPLACE INSULATION ON ALL EXISTING TO REMAIN HVAC PIPING 16. ADDITIONAL CONTROLS TO BE PROVIDED AS AN EXTENSION OF THE EXISTING CONTROLS SCHEME AND ARE TO BE INSTALLED BY CONTRACTOR PER MANUFACTURER'S RECOMMENDATION. DDC CONTROLS ARE TO BE CONNECTED TO THE CAMPUS CENTRAL WORK STATION AS SHOWN ON CONTROL DIAGRAMS. 17. ANY WORK TO EQUIPMENT, IT'S ACCESSORIES OR SUPPORTING COMPONENTS UNDER WARRANTY SHALL BE PROVIDED ONLY BY A CONTRACTOR OR VENDOR THAT WILL MAINTAIN THE VALIDITY OF THE WARRANTY. 18. SIZES AND LOCATIONS OF ALL EXISTING EQUIPMENT, DUCTWORK, PIPING, CONTROLS, SUPPORTS, ELECTRICAL AND APPURTENANCES ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND START Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 OF WORK. CONTRACTOR SHALL COORDINATE ALL RELATED EFFORTS WITH THE OWNER. 19. PROVIDE DRAINS AT ALL LOW POINTS AND AIR VENTS AT ALL HIGH POINTS FOR No. Description Date HYDRONIC SYSTEMS. 20. REPAIR/REAPPLY EXISTING INSULATION THAT BECOMES DAMAGED OR REMOVED DURING CONSTRUCTION. 21. ALL DUCTWORK, AIR TERMINAL BOXES, DIFFUSERS, GRILLES, PIPING, VALVES, ETC OUTSIDE OF THE LIMIT OF WORK AREA REPRESENT EXISTING TO REMAIN ITEMS THAT ARE NOT PART OF THIS CONTRACT. ITEMS ARE INDICATED FOR REFERENCE ONLY UNLESS NOTED OTHERWISE. 22. CONTRACTOR SHALL COORDINATE PHASING OF UTILITIES TO MINIMIZE IMPACT ON SERVICES / FACILITIES TO REMAIN IN OPERATION DURING CONSTRUCTION. Revisions 23. USE OF MERCURY THERMOMETERS IS PROHIBITED. Drawing Title 24. ALL NEW DUCT AND HYDRONIC SYSTEMS SHALL BE LEAK TESTED. 25. ALL EXISTING TO REMAIN HOT WATER S & R PIPING, STEAM & CONDENSATE PIPING, MECHANICAL NOTES AND SYMBOLS DRAIN PIPING SHALL BE PROVIDED WITH NEW INSULATION & ALL-SERVICE JACKET. Phase CONCEPT A/E Project Number 12-0009.015 Date 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By UP/FF Checked By AK Sheet 1:1 Number M001 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' SCALE: 1" = 1'-0" 1' SCALE: 1/2" = 1'-0" SCALE: 1/4" = 1'-0" Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 SCALE: 3/16" = 1'-0" No. Description Date 0 Revisions SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' SCALE: 3/4" = 1'-0" 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1' 3' 2 M401 2' 0 1/2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E Drawing Title SCOPE OF WORK MECHANICAL FIRST FLOOR OVERALL PLAN 1 M401 Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 1 M100 W MECHANICAL FIRST FLOOR OVERALL PLAN 3/16" = 1'-0" N CADD Plot Scale Revit Model Drawn By FF Checked By AK Sheet E 100% 1:1 Number M100 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' SCALE: 1" = 1'-0" 1' 3' 0 1/2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1/4" = 1'-0" Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 SCALE: 3/16" = 1'-0" No. F TELECOM EQUIPMENT RM 1 M402 Drawing Title SCOPE OF WORK MECHANICAL SECOND FLOOR OVERALL PLAN Phase 32' CONCEPT 1 SCALE: 1/16" = 1'-0" 16' M101 8' Date Revisions SCALE: 1/8" = 1'-0" 8' 4' 0 Description ROOM F 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 1' 2' DN 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION A/E Project Number MECHANICAL SECOND FLOOR OVERALL PLAN 12-0009.015 3/16" = 1'-0" Date S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By FF Checked By AK Sheet E 100% 1:1 Number M101 1. FOR ABBREVIATIONS, SYMBOLS AND GENERAL NOTES REFER TO DRAWING M001. SCALE: 1-1/2" = 1'-0" DEMOLITION KEY NOTES 2. REMOVE EXISTING RETURN AIR GRILLE . REBALANCE THE RETURN GRILLE AS INDICATED ON THE NEW WORK DRAWING. PROVIDE PRE-CONSTRUCTION TAB MEASUREMENT FOR THE EXISTING RETURN DIFFUSER TO ENGINEER BEFORE COMMENCEMENT OF CONSTRUCTION. SCALE: 1" = 1'-0" 1' # 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 0 SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' UP 2' 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 1. REMOVE SUPPLY AIR DIFFUSER. PROVIDE PRE-CONSTRUCTION TAB MEASUREMENT FOR THE EXISTING SUPPLY DIFFUSER TO ENGINEER BEFORE COMMENCEMENT OF CONSTRUCTION. 2' 0 1' 2. PROVIDE PRE-DEMOLITION TAB TO DETERMINE EXISTING SUPPLY AIR, RETURN, OUTSIDE AND AIR SETTINGS (E) 6"Ø DRYER EXHAUST 6"ø 8" ø 8" ø 8"ø 12"x10" 24"x12" 30"x12" 18"x6" 18"x6" SCALE: 1/2" = 1'-0" 24X24 RA DIFFUSER M400 (E) RAD 20x14 RA DIFFUSER 24"x12" (E)24X12 RA DUCT (E)12X6 SA DUCT MECHANICAL FIRST FLOOR APARTMENT- DEMOLITION 3/16" = 1'-0" Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 SCALE: 1/4" = 1'-0" 4' 2' OFFICE SMALL SCALE: 3/16" = 1'-0" (E) FLUE GAS No. Description ø 6" (E) FN-6 14"x6" 18"x12" (E) KITCHEN HOOD (E) RAD 18"x12" 2 CAP & SEAL DUCT (E) SAD Revisions Drawing Title SCOPE OF WORK 14"x6" MECHANICAL FIRST FLOOR ENLARGED PLANS DEMOLITION 1 RELOCATE EXISTING Phase 32' CONCEPT A/E Project Number SCALE: 1/16" = 1'-0" 16' 12-0009.015 8' Date 12"x8" SCALE: 1/8" = 1'-0" 8' 4' 0 (E) COMBUSTION AIR INTAKE (E) 24x14 , EXHAUST DUCT UPTO EF-1 LOCATED ON ROOF. 16' 0 4' 8' 12' 0 (E) SAD 8" ø 1 8' 0 1' 2' 10"x6" 12"x4" 4' 12"x10" 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL NOTES 2 M400 MECHANICAL FIRST FLOOR KITCHEN - DEMOLITION Date 3/16" = 1'-0" S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By UP/FF Checked By AK Sheet E 100% 1:1 Number M400 2. RELOCATE SPRINKLER PIPING AND SPRINKLER HEADS AS REQUIRED TO ACCOMMODATE THE ERU-1, SUPPLY, RETURN, OUTDOOR AND EXHAUST AIR DUCTWORK AND ASSOCIATED ACCESSORIES. THE RELOCATED SPRINKLER PIPING AND SPRINKLER HEADS TO COMPLY WITH NFPA 13. PROVIDE SPRINKLER HEADS TO MATCH EXISTING SPRINKLER HEADS. SCALE: 1-1/2" = 1'-0" 0 1' 1. FOR ABBREVIATIONS, SYMBOLS AND GENERAL NOTES REFER TO DRAWING M001. 3. COORDINATE THE NEW EQUIPMENT, DUCTWORK, ACCESSORIES, ETC. WITH EXISTING STRUCTURE AND EXISTING EQUIPMENT, DUCTWORK, LIGHTS, PIPES, ETC.. CASEY COMMUNITY CENTER INTERIOR RENOVATION 4. CONNECT THE EXISTING HOOD SYSTEM TO THE EXISTING FIRE SUPPRESSION SYSTEM. # 2' NEW WORK KEY NOTES SCALE: 1" = 1'-0" 0 1/2' 1' MAIN LOBBY 10 4. PROVIDE SUPPORTS FOR MOUNTING ERU-1 AS PER MANUFACTURER'S RECOMMENDATION. PROVIDE SERVICE CLEARANCE AS REQUIRED. 3' SCALE: 3/4" = 1'-0" 2' CAPPED AND SEALED DUCT CONFERENCE CUH-2 2 6"x6" IU-2 IU-3 12"x4" 6"ø 12"x6" SCALE: 1/2" = 1'-0" 3 OFFICE LARGE 4"ø 12"x10" (E) 8" OAD EXISTING TO REMAIN OFFICE SMALL (E) SAD CUH-2 IU-5 2 12x6 SAD TO FLOOR ABOVE (E) CU (E)12x4 SAD TO FLOOR ABOVE EXISTING TO REMAIN CU-1 1 30"x12" (E)18x6 SAD TO FLOOR ABOVE EXISTING TO REMAIN CUH-2 BACKDRAFT DAMPER (E) AHU-1 (E) RAD (E)24x12 RAD FROM FLOOR ABOVE EXISTING TO REMAIN (E) CU CU-2 12x6 SAD TO FLOOR ABOVE Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 MECHANICAL FIRST FLOOR - APARTMENT AND BATHROOM - ENLARGED PLAN 3/16" = 1'-0" SCALE: 3/16" = 1'-0" No. (E) 24x14 , EXHAUST DUCT UPTO EF-1 LOCATED ON ROOF. ø 6" 8"x8" (E) FN-6 Revisions EF-2 SD-2(600) (TYP. OF 3) (100) 14"x6" SCALE: 1/8" = 1'-0" 8' 4' 0 REROUTE SPRINKLER LINE AS NECESSARY TO PROVIDE ACCESS TO MECH EQUIPMENTS M 8 (E) KITCHEN HOOD SCALE: 1/16" = 1'-0" 8' 16' 32' 8"x8" KITCHEN MECHANICAL FIRST FLOOR ENLARGED PLAN MERV-8 FILTER HOUSING IN ATTIC 9 7 16"x12" Drawing Title SCOPE OF WORK 5 18"x12" 18"x12" 24"x12" DW 1 5 8"x8" DN. TO DISHWASHER HOOD 24"x12" Phase UPTO 24"x12" GOOSENECK ON ROOF SF-1 IN ATTIC CONCEPT A/E Project Number 12-0009.015 M Date 24"x12" ELECTRIC DUCT HEATER EDH-1 IN ATTIC 24"x12" S 6 35% 60% 90% M401 MECHANICAL FIRST FLOOR - KITCHEN - ENLARGED PLAN E W 3/16" = 1'-0" N 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By UP/FF Checked By AK Sheet 2 Date 14"x14" EA LOUVER 12"x8" (E)18x12 RA DUCT FROM DAYCARE Description (E) COMBUSTION AIR INTAKE (E) FLUE GAS (E)12x6 SA DUCT TO DAYCARE 16' 0 4' 8' 12' M401 (E)18x6 SAD TO FLOOR ABOVE EXISTING TO REMAIN (E) SAD MIN 10' APART 1 (E) SAD (E) SAD BACKDRAFT DAMPER T MECH RM. 24"x12" (E) SAD 6"ø PH-1 4 IU-4 3 ERV-1 12x6 SAD TO FLOOR ABOVE SCALE: 1/4" = 1'-0" 6"x4" 9. CONTRACTOR TO FIELD VERIFY THAT THE FIRE SUPPRESSION SYSTEM IS CONNECTED TO FIRE ALARM. 12"x6" STORAGE 6"x4" EG-1(75) T 6"ø T 8. EXISTING FURNACE FN-6 TO BE REBALANCED TO THE ORIGINAL SUPPLY, RETURN AND OUTDOOR AIR. EQUALLY DISTRIBUTE THE CFM OF REMOVED KITCHEN RETURN GRILLE TO ALL RETURN GRILLES ASSOCIATED WITH EXISTING FURNACE FN-6. 12"x6" T 4' 2' 1' EG-1(30) (E) EXHAUST DUCT IU-1 3 6"ø 0 7. REBALANCE EXISTING SUPPLY AIR DIFFUSER TO THE CFM INDICATED ON THE DRAWING . SD-1(115) SD-1(120) 6"ø 1' 0 4"Ø DRYER EXHAUST 3 8' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 6. SEAL AND PATCH DUCT PENETRATION UP TO GOOSENECK. PROVIDE ROOF CURB FOR GOOSENECK TO MATCH EXISTING ROOF PITCH. REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS. CUH-1 4' NIKA A+E 5. PROVIDE SUPPORTS FOR MOUNTING EXHAUST FAN AS PER MANUFACTURER'S RECOMMENDATION. PROVIDE SERVICE CLEARANCE AS REQUIRED. 4 2' 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 3. PROVIDE SUPPORTS FOR MOUNTING CASSETTE UNIT AS PER MANUFACTURER'S RECOMMENDATION. PROVIDE SERVICE CLEARANCE AS REQUIRED. ENTRY 0 1. EXISTING AHU-1 SUPPLY FAN TO BE BALANCED TO 1750 CFM BY ADJUSTING BELTS, SHEAVES, PULLEYS, ETC. AS REQUIRED. PROVIDE NEW BELTS, SHEAVES, PULLEYS, ETC. AS REQUIRED. BALANCE THE RETURN AND OUTDOOR AIR TO 1515 CFM AND 235 CFM RESPECTIVELY. 2. PROVIDE PVC/RUBBER MOUNTING PAD FOR MOUNTING CONDENSING UNIT. REFER TO DETAIL ON DWG. 501 FOR MORE DETAILS. UP 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL NOTES 1:1 Number M401 1. FOR ABBREVIATIONS, SYMBOLS AND GENERAL NOTES REFER TO DRAWING M001. SCALE: 1-1/2" = 1'-0" NEW WORK KEY NOTES 2. RELOCATED THERMOSTAT WITH ALL ASSOCIATED WIRING AND CONTROLS. 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 SCALE: 1" = 1'-0" 1' # 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com T TG-1 (200) 2 SCALE: 1/2" = 1'-0" 2' 1' 0 10"x10" TELECOM EQUIPMENT RM 1515 CFM /24X24 RA WALL DIFFUSER REMAIN TO EXIST SG-2(375) SG-2(375) (E) 24X12 RA DUCT REMAIN TO EXIST STORAGE-3 RM 24"x12" STORAGE-2 RM SG-1(195) SG-1(195) 12X6 SA DUCT FROM FLOOR BELOW MECHANICAL SECOND FLOOR - GENERAL PURPOSE - ENLARGED PLAN 3/16" = 1'-0" Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 SCALE: 3/16" = 1'-0" No. Description Date SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 4' 8' 12' SCALE: 1/4" = 1'-0" M402 TG-1 (390) 1 12X6 SA DUCT FROM FLOOR BELOW 1 8' 4' 2' TG-1 (390) F 10"x10" SG-1(175) 0 ROOM F 24"x12" TG-1 (200) SG-1(200) 4' 0 SCALE: 3/4" = 1'-0" NIKA A+E 1' 3' UP 2' 0 1/2' CASEY COMMUNITY CENTER INTERIOR RENOVATION 1. REBALANCE WALL MOUNTED RETURN AIR GRILLE TO CFM INDICATED ON THE DRAWING. 2' 0 1' 2. COORDINATE THE NEW EQUIPMENT, DUCTWORK, ACCESSORIES, ETC. WITH EXISTING STRUCTURE AND EXISTING EQUIPMENT, DUCTWORK, LIGHTS, PIPES, ETC.. Revisions Drawing Title SCOPE OF WORK MECHANICAL SECOND FLOOR ENLARGED PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GENERAL NOTES S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W N CADD Plot Scale Revit Model Drawn By FF/UP Checked By FB Sheet E 100% 1:1 Number M402 HANGER ROD SUPPORTS. SECURE TO STRUCTURE ABOVE WITH VIBRATION ISOLATORS (TYP) INSULATED DRAIN LINE STANDARD DUCT MADE WATER TIGHT STIFFNERS MAY BE INSIDE BUILDING STRUCTURE MAIN DUCT ANGLE REVITED OR SPOT WELDED AS REQUIRED STRAIGHT 3/8" SCREEN 45 D-3/4 D HEEL R 1/50 - 1/100 CT DU INSULATED REFRIGERANT PIPING 3/4 D THROAT RADIUS 135° MIN. BRANCH DUCT SI BALANCING DAMPER (BD.) ZE MAY BE USED ANYWHERE + MAX (27")700 mm % 25 R R = W/2 MAIN DUCT 12" MIN. FLASHING (BY OTHERS) 18" MIN. 1 M501 INTEGRAL CONDENSATE PUMP CASSETTE1UNIT DETAIL M501 INSULATED BRANCH DUCT W SPECIFIED DUCT SIZE 2 N.T.S. 6" ROOFING (BY OTHERS) 8" MIN. ACCESS PANEL TO ELECTRICAL, COIL CONNECTIONS, AND MOTOR/FAN ASSEMBLY 45 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 BALANCING DAMPER (BD.) GOOSNECK DETAIL 1 USE ONLY AT LAST TAKEOFF BEFORE OUTLETS & THEN ONLY WHERE RECTANGULAR RUNOUTS ARE INDICATED ON DRAWINGS N.T.S. POWER TO INDOOR UNIT REFRIGERANT CASEY COMMUNITY CENTER INTERIOR RENOVATION NIKA A+E LINES 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com MAIN DUCT AIRFLOW 45 EXIST. CONC. BALCONY 6" BRANCH DUCT PVC/RUBBER MOUNTING PAD RECTANGULAR 15°M AX . BALANCING DAMPER (BD.) ROUND AIRFLOW 3/8" DIA. HILTI HY 70 ADHESIVE ANCHOR. 3" EMBEDMENT INTO PVC/RUBBER PAD @ ALL FOUR CORNERS CONDENSER MOUNTED DETAIL 15°MA X. N.T.S. THIS CONNECTION SHALL BE USED AT ALL BRANCHES FROM MAINS AND SUB-MAINS. BALANCING DAMPERS SHALL BE PROVIDED AS SHOWN IN ADDITION TO THOSE INDICATED ON THE PLANS. TYPICAL DUCTWORK TRANSITION PLAN OR SIDE VIEW SUPPORT RODS TO STRUCTURE NOTE: UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY. THE VMC GROUP ISOLATION HANGER 5 M501 FAN DUCT 6 M501 SUPPLY DUCTWORK TAKE-OFFS N.T.S TYPICAL DUCTWORK TRANSITION N.T.S. Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 DUCT ELEVATION FAN DUCT DUCT PLAN VIEW SEE SPECIFICATIONS FOR CLAMPS AND SEALANT (TYP.) NOTE: FAN REQUIRES POSITIVE ATTACHMENT TO SUPPORTING CHANNELS OF ANGELS. 4 M501 IN-LINE FAN DETAIL FLEXIBLE DUCT SIZE SAME AS DIFFUSER INLET: 1500 mm MAX LENGTH. N.T.S DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN No. BRANCH DUCT SUPPLY OR RETURN, FOR THERMAL INSULATION SEE SPECIFICATIONS SUPPORT SADDLE FROM STRUCTURE Date CONICAL OUTLET USE RIGID ELBOWS FOR CHANGE OF DIRECTION GREATER THAN 45° PITCH DOWN TOWARD DRAIN Description R SHALL EQUAL OR BE GREATER THAN W. W CLEAN OUT Revisions Drawing Title A 3 M501 USE ONLY AT LAST TAKEOFF BEFORE OUTLETS & THEN ONLY WHERE ROUND RUNOUTS ARE INDICATED ON DRAWINGS PEN DRAIN SEE CONTINUATION IN PLUMBING DRAWING SHEET METAL SADDLE DRAIN PAN MECHANICAL DETAILS VOLUME DAMPER W/ LOCKING QUAD Phase CONCEPT OPEN DRAIN UNIT TYPE DRAW THRU A B 1" PLUS X X STANDARD RADIUS ELBOW CEILING NOTE: NOTE: 1. REFER TO STRUCTURAL DRAWINGS FOR SEISMIC SUPPORT REQUIREMENTS. Date THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND. ALL STANDARD RADIUS ELBOWS SHOWN ON FLOOR PLANS MAY BE MADE SHORT RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA. WHERE X = STATIC PRESSURE IN PAN 7 M501 CASSETTE UNIT DRAIN TRAP DETAIL N.T.S A/E Project Number 12-0009.015 1. 2. 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 8 TYPICAL CEILING SUPPLY OR RETURN AIR DEVICE N.T.S. 9 M501 DUCTWORK RADIUS ELBOWS N.T.S CADD Plot Scale Revit Model Drawn By FF/UP Checked By AK Sheet M501 100% R TYPICAL DIFFUSER OR REGISTER IN CEILING. 35% 1:1 Number M501 DUCT HEATER SCHEDULE INDOOR DESIGN CONDITIONS SUMMER (°F) WINTER (°F) RELATIVE HUMIDITY (%) 70 30 - 65 75 OUTDOOR DESIGN CONDITIONS COOLING DB (°F) COOLING WB (°F) 94.3 HEATING DB (°F) 75.1 MARK LOCATION SYSTEM EDH-1 1ST FLOOR ELECTRIC PH-1 1ST FLOOR ELECTRIC AIR FLOW (CFM) VOLT PH HZ HEATING CAPACITY (KW) MANUFACTURER MODEL FINNED TUBE DUCT HEATER 1800 208 3 60 20 MARLEY 1,2,3,5 OPEN COIL DUCT HEATER 105 120 1 60 0.7 MARLEY 1,2,4,6 TYPE CASEY COMMUNITY CENTER INTERIOR RENOVATION NOTES: 1. 2. 3. 4. 5. 6. 7. 16.3 PROVIDE SUPPORTS TO MOUNT THE ELECTRIC DUCT HEATER AS PER MANUFACTURER'S RECOMMENDATION. BALANCE TO AIRFLOW INDICATED ON FLOORS PLANS. PROVIDE SCR CONTROLLER. SET THE DUCT MOUNTED THERMOSTAT TO 60 F (ADJUSTABLE). PROVIDE TWO STAGE HEATER WITH DUCT MOUNTED CONTROLLER. INTERLOCK DUCT HEATER UH-1 WITH EXHAUST FAN SF-1. INTERLOCK DUCT HEATER PH-1 WITH ERV-1. SET THE DUCT MOUNTED THERMOSTAT TO 20 F (ADJUSTABLE). PROVIDE DUCT MOUNTED THERMOSTAT. ENERGY RECOVERY VENTILATOR SCHEDULE MARK SERVICE CONFERENCE ROOM LARGE OFFICE ERV-1 LOCATION SUPPLY EXHAUST VOLUME VOLUME (CFM) (CFM) SIZE (IN) CEILING 35"LX40"WX13"H 105 105 OUTSIDE AIR WINTER SUPPLY AIR SUMMER WINTER ROOM AIR SUMMER WINTER SA/EA MOTOR DATA EFFICIENCY TEMPERATURE RECOVERY SUMMER 14°F 10% RH 95°F 50% RH 58°F 40% RH 79°F 62% RH 70°F 40% RH 75°F 50% RH ENTHALPY COOLING 81/79% ENTHALPY HEATING 63/61% 79/77% INPUT WATT ESP 67/82 0.06/0.08 ELECTRICAL V / PH / Hz 208/1/60 BASIS OF DESIGN MITSUBISHI LOSSNAY NOTES 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 1,2,3,4,5,6,7 NOTES: 1. 2. 3. 4. 5. 6. 7. PROVIDE SUPPORTS AND INSTALL THE ENERGY RECOVERY UNIT ABOVE CEILING AS PER MANUFACTURER'S RECOMMENDATION.. INSTALL ENERGY RECOVERY UNIT IN THE CEILING WITH ACCESSIBLE SERVICE CLEARANCE AS PER MANUFACTURE'S RECOMMENDATION. ERU-1 SHALL BE OPERATIONAL DURING USER DEFINED OCCUPIED HOURS. ERV-1 SHALL BE CONTROLLED BY CONTACT CLOSURE FROM AN EXTERNAL TIMER. PROVIDE BACKDRAFT DAMPER ON THE OUTDOOR AIR INTAKE AND EXHAUST AIR OUTLET. ENERGY RECOVERY UNIT SUPPLY AND EXHAUST FANS SHALL BE BALANCED TO THE CFM INDICATED ABOVE IN THE SCHEDULE. PROVIDE 1 YEAR MANUFACTURER'S PARTS, DEFECTS, & LABOR WARRANTY; FOR ENERGY TRANSFER CORE, PROVIDE 10 YEAR WARRANTY AGAINST DEFECTS IN MATERIAL AND WORKMANSHIP. NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com CASSETTE SPLIT SYSTEM HEAT PUMP SCHEDULE (EVAPORATOR UNIT) SUPPLY FAN SPACE SERVED TAG CU-1 AIR VOLUME (CFM) TYPE OUTSIDE AIR (CFM) DX COOLING COIL FAN MOTOR SELECTED SPEED V / PH / HZ MCA FLA TOTAL COOLING CAPACITY (BTUH) ENT. AIR TOTAL HEATING CAPACITY (BTUH) LVG. AIR DB (°F) WB (°F) DB (°F) WB (°F) BASIS OF DESIGN: MANUFACTURER / MODEL NOTES IU-1 STORAGE - OFFICE CEILING MOUNTED 350 30 MEDIUM 208 / 1 / 60 1.0 0.28 11,650 10,440 80 67 55 54 MITSUBISHI SLZ-KA12NA 1,2,3,4,5,6,7 IU-2 CONFERENCE RM CEILING MOUNTED 320 40 MEDIUM 208 / 1 / 60 1.0 0.23 8,822 8,365 80 67 55 54 MITSUBISHI SLZ-KA09NA 1,2,3,4,5,6,7 IU-3 CONFERENCE RM CEILING MOUNTED 320 35 MEDIUM 208 / 1 / 60 1.0 0.23 8,822 8,365 80 67 55 54 MITSUBISHI SLZ-KA09NA 1,2,3,4,5,6,7 IU-4 LARGE OFFICE CEILING MOUNTED 320 30 MEDIUM 208 / 1 / 60 1.0 0.23 8,822 8,365 80 67 55 54 MITSUBISHI SLZ-KA09NA 1,2,3,4,5,6,7 IU-5 SMALL OFFICE CEILING MOUNTED 320 15 MEDIUM 208 / 1 / 60 1.0 0.23 8,822 8,365 80 67 55 54 MITSUBISHI SLZ-KA09NA 1,2,3,4,5,6,7 CU-2 NOTES: WALL MOUNTED ELECTRIC HEATER SCHEDULE MARK CUH-1 CUH-2 LOCATION 1ST FLOOR 1ST FLOOR SYSTEM ELECTRIC ELECTRIC AIR FLOW (CFM) TYPE RECESSED 65 RECESSED 65 VOLT PH 208 HZ 1 208 60 1 60 HEATING CAPACITY (KW) 1.5 0.75 MANUFACTURER MARLEY MARLEY 1. REFRIGERANT R-410A. 2. EVAPORATOR UNIT FAN SHALL HAVE LOW, MEDIUM, AND HIGH SETTINGS WITH ON/OFF CAPABILITY. 3. PROVIDE UNIT DISCONNECT SWITCH. 4. PROVIDE CONDENSATE HIGH LEVEL SAFETY SWITCH TO TURN OFF THE CASSETTE UNIT. 5. 6. PROVIDE UNIT WITH MERV 8 AIR FILTER. PROVIDE 7 DAY PROGRAMMABLE WALL MOUNTED THERMOSTAT. PROVIDE SUPPORTS WITH VIBRATION ISOLATORS AND INSTALL WITH SERVICE ACCESS THE CASSETTE UNITS ABOVE CEILING AS PER MANUFACTURER'S RECOMMENDATION. SPLIT SYSTEM HEAT PUMP SCHEDULE (CONDENSING UNIT) MODEL 1,2,3,4 TOTAL COOLING CAPACITY RANGE (BTUH) TAG 1,2,3,4 TOTAL HEATING CAPACITY RANGE (BTUH) UNIT ELECTRICAL DATA MIN. SEER V/PH/HZ MCA MOCP COMPRESSOR CONDENSER FAN MOTOR (FLA) BASIS OF DESIGN: MANUFACTURER / MODEL CU-1 28,400 28,600 18 208/1/60 30 40 1 1.9 MITSUBISHI MXZ-3C30NAHZ 1,2,3,4,5,6 CU-2 18,000 22,000 17 208/1/60 29 40 1 1.9 MITSUBISHI MXZ-2C20NAHZ 1,2,3,4,5,6 NOTES: 1. 2. 3. 4. PROVIDE UNIT MOUNTED THERMOSTAT. PROVIDE THERMAL OVERHEAT PROTECTION. PROVIDE DISCONNECT SWITCH. COLOR OF THE GRILLE TO BE APPROVED BY THE ARCHITECT. TYPE SERVICE AIRFLOW (CFM) No. NOTES 1. AIR DEVICE SCHEDULE TAG NOTES NECK SIZE (IN) SIZE MAX NC AIRFLOW PATTERN BASIS OF DESIGN Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 REFRIGERANT R-410A. 6. Description Date PROVIDE MOUNTAING PAD AS PER MANUFACTURE'S RECOMMENDATION. 2. PROVIDE UNIT DISCONNECT SWITCH. 3. PROVIDE REFRIGERANT LINE SETS BETWEEN OUTDOOR AND INDOOR UNIT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 4. HEAT PUMP. 5. PROVIDE LOW AMBIENT KIT. NOTES FAN SCHEDULE MOTOR SD-1 4 WAY DIFFUSER SUPPLY 0-120 6Ø 12x12 30 4-WAY TITUS TMS 1,2,3,4,5 SD-2 4 WAY DIFFUSER SUPPLY 121-600 12Ø 24x24 30 4-WAY TITUS PAS 1,2,3,4,5,6 SUPPLY 0-200 8x6 10x8 30 SINGLE DEFLECTION TITUS 301FS 1,2,3,4,5 SUPPLY 201-400 10x10 12x12 30 SINGLE DEFLECTION TITUS 301FS 1,2,3,4,5 SG-1 SG-2 TG-1 EG-1 SUPPLY GRILLE SUPPLY GRILLE TRANSFER GRILLE EXHAUST GRILLE TAG TYPE EF-1 UPBLAST EF-2 INLINE SERVICE LOCATION AIRFLOW (CFM) TOTAL SP (IN. WG.) DRIVE RPM ROOF 1800 0.7 BELT 1595 1/2 1ST FLOOR 300 0.4 DIRECT 1468 1/6 HP VOLT PH Hz WEIGHT (LBS) 1725 208 1 60 65 GREENHECK CUBE-131-5 2,3,6 1725 208 1 60 41 GREENHECK SQ-85-VG 1,2,4 RPM MANUFACTURER NOTES Revisions Drawing Title TRANSFER EXHAUST 0-390 0-100 10x10 6x4 12x12 12x12 30 30 - TITUS PAR TITUS PAR COOKING HOOD DISHWASHER NOTES: PROVIDE FRAME AND / OR ACCESSORIES AS REQUIRED TO MATCH CEILING / WALL TYPE. BALANCE TO AIRFLOW INDICATED ON FLOORS PLANS. UNLESS OTHERWISE INDICATED ON THE FLOOR PLANS, DUCT RUNOUTS SHALL MATCH AIR DEVICE NECK. PROVIDE SQUARE TO ROUND ADAPTERS AS REQUIRED. ALUMINUM CONSTRUCTION. DIFFUSER TO BE IN CONFORMANCE TO NSF. MECHANICAL SCHEDULES Phase SF-1 INLINE - - KITCHEN 1ST FLOOR 1800 1.9 BELT 2270 1 1/2 1725 208 3 60 95 GREENHECK - - - - - - - - - - - - BSQ-120-15 1,2,3,4,5 - CONCEPT 1,2,5 1,2,3,4,5 - A/E Project Number 12-0009.015 Date NOTES. 1. 2. 3. 4. 5. 6. MODEL 1. PROVIDE SUPPORTS WITH VIBRATION ISOLATORS TO MOUNT THE FANS AS PER MANUFACTURER'S RECOMMENDATION 2. PROVIDE UNIT DISCONNECT SWITCH. 3. 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By UP/FF EXHAUST FAN EF-1 TO BE INTERLOCKED WITH EXISTING KITCHEN HOOD. PROVIDE MANUAL ON-OFF HOOD SWITCH. PROVIDE ADEQUATE QUANTIY OF RELAYS TO ENERGIZE THE EXHAUST FAN EF-1 WHEN KITCHEN HOOD IS ON AND VICE VERSA. Checked By AK 4. EXHAUST FAN EF-2 TO BE INTERLOCKED WITH DISHWASHER HOOD. PROVIDE MANUAL ON-OFF HOOD SWITCH. PROVIDE ADEQUATE QUANTIY OF RELAYS TO ENERGIZE THE EXHAUST FAN EF-2 WHEN DISHWASHER HOOD IS ON AND VICE VERSA. Sheet 5. KITCHEN MAKE UP AIR FAN SF-1 TO BE INTERLOCKED WITH EXHAUST FAN EF-1. KITCHEN MAKE UP AIR FAN SF-1 SHALL ENERGIZE AFTER EXHAUST FAN EF-1 IS ENERGIZED. . EXHAUST FAN EF-1 TO BE INSTALLED ON EXISTING ROOF CURB. CONTRACTOR TO VERIFY THE SIZE AND OPERING OF THE EXISTING ROOF CURB BEFORE ORDERING THE EXHAUST FAN. 6. 1:1 Number M601 PIPING PIPING SYMBOLS SYMBOLS CW NEW DOMESTIC DOMESTIC COLD WATER WATER (CW) NEW HW NEW NEW DOMESTIC HOT WATER (HW) HWR NEW DOMESTIC HOT WATER RETURN (HWR) NEW SANITARY PIPE (SAN) ABBREVIATIONS ABBREVIATIONS AP ACCESS PANEL ABV ABOVE AFF ABOVE ABOVE FINISH FINISH FLOOR BEL BELOW BELOW BFPR BACKFLOW PREVENTER BV BALANCING VALVE NEW VENT PIPE PIPE (V) CLG CEILING G NATURAL GAS PIPE NEW NATURAL CO CLEANOUT P P PROPANE GAS PIPE PROPANE (E) EXISTING FCO FLOOR CLEANOUT FD FLOOR DRAIN DHWT DOMESTIC HOT WATER TANK NEW SHUT-OFF VALVE HB HOSE HOSE BIBB BIBB DEMOLITION WORK OHB OPEN HUB HUB DRAIN DRAIN OPEN SP SOIL PIPE SS SOIL STACK TP TRAP PRIMER PRIMER V VENT VENT VP VENT VENT PIPE VS VENT STACK VENT VTR VENT VENT THRU THRU ROOF ROOF O O FUEL OIL PIPE TP TP TRAP PRIMER PIPE CW EXISTING EXISTING DOMESTIC DOMESTIC COLD COLD WATER WATER (CW) (CW) HW EXISTING EXISTING DOMESTIC DOMESTIC HOT WATER WATER (HW) HWR EXISTING DOMESTIC HOT WATER RETURN RETURN (HWR) (HWR) EXISTING EXISTING SANITARY PIPE (SAN) EXISTING VENT PIPE (V) EXISTING SHUT-OFF VALVE NG NATURAL GAS GAS PIPE NATURAL LP LIQUID PROPANE PROPANE PIPE GENERAL GENERAL SYMBOLS SYMBOLS CONNECT CONNECT NEW NEW TO TO EXISTING PLUMBING PLUMBING GENERAL GENERAL NOTES: NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE SITE AND VERIFYING ALL EXISTING FIELD CONDITIONS PRIOR TO SUBMISSION SUBMISSION OF OF HIS HIS BID. BID. POINT OF DISCONNECT ELBOW ELBOW DOWN 2. CONTRACTOR IS RESPONSIBLE RESPONSIBLE FOR FOR COORDINATING COORDINATING HIS HIS WORK WORK WITH THE THE WORK OF ALL OTHER OTHER TRADES TRADES AND AND MAKING MAKING ANY ANY NECESSARY NECESSARY MODIFICATIONS MODIFICATIONS TO HIS WORK AT NO ADDITIONAL COST, INCLUDING ALL OFFSETS. ELBOW UP CONNECTION, 45° 45° OR OR 90° TOP CONNECTION, SHUT SHUT OFF VALVE GAS SHUT OFF VALVE BOTTOM CONNECTION, CONNECTION, 45° 45° OR OR 90° BOTTOM TP 4. CONTRACTOR SHALL REMOVE EXISTING EQUIPMENT AND MATERIALS PERTAINING TO HISCONTRACT HISCONTRACT AS AS SPECIFIED OR AS REQUIRED WHETHER SHOWN ON THE DRAWINGS OR NOT, TO PREPARE PREPARE FOR FOR THE THE NEW NEW WORK. WORK. 5. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH LOCAL CODES. THESE CODES SHALLBE SHALLBE FOLLOWED FOLLOWED AS MINIMUM PROVIDING HIGHER HIGHER GRADES GRADES OF OF MATERIAL AND WORKMANSHIP WHERE REQUIRED BY THESE DOCUMENTS.PROVIDE DOCUMENTS.PROVIDE ALL ALL TESTS TESTS REQUIRED REQUIRED BY LOCAL CODES. SIDE CONNECTION 6. CITY OF GAITHERSBURG GAITHERSBURG WILL REIMBURSE REIMBURSE ALL PERMITTING PERMITTING FEES TO THE CONTRACTOR. RISE OR DROP IN PIPE 7. SUBMIT ASSEMBLED PRINTED INSTRUCTIONS FOR THE OPERATION AND MAINTENANCE OF EACH ITEM INSTALLED ALONG ALONG WITH EQUIPMENT EQUIPMENT CUTS CUTS AND AND CONTROL CONTROL WIRING WIRING DIAGRAMS. UNION BFPR 3. CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATION OF ANY EXISTING MINOR INTERFERENCE'S, INCLUDING CONDUIT, CONDUIT, HANGERS, HANGERS, ETC., ETC., AT NO ADDITIONAL COST. CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 CHECK VALVE 8. SUBMIT COORDINATED SHOP DRAWINGS FOR REVIEW. THE SHOP DRAWINGS SHALL INDICATE WORK OF OTHER TRADES AND MUST BE SUBMITTED PRIOR TO FABRICATION AND INSTALLATION. BALANCING VALVE 9. SUBMIT EQUIPMENT SPECIFICATIONS FOR REVIEW BEFORE PURCHASE. HOSE BIBB HOSE 10. CONTRACTOR SHALL SHALL GUARANTEE GUARANTEE ALL ALL WORK WORK AND AND MATERIAL MATERIAL FOR FOR ONE ONE YEAR AFTER COMPLETION AGAINST AGAINST ALL ALL DEFECTS OF MATERIAL, EQUIPMENT AND WORKMANSHIP. NIKA A+E WALL HYDRANT 11. PROVIDE COMPETENT OPERATING OPERATING TECHNICIAN TO INSTRUCT THE OWNER OWNER IN THE OPERATION AND MAINTENANCE MAINTENANCE OF THE INSTALLED EQUIPMENT. 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com BACKFLOW PREVENTER PRIMER TRAP PRIMER 12. PROVIDE ACCESS PANELS FOR ALL VALVES OR ANY PIECE OF EQUIPMENT WHEN NECESSARY TO LOCATE ABOVE NON-ACCESSIBLE CEILINGS. SUBJECT TO THE APPROVAL OF THE ARCHITECT. NO EQUIPMENT EQUIPMENT SHALL SHALL BE BE LOCATED LOCATED DIRECTLY DIRECTLY ABOVE ABOVE WALLS. SHOCK ARRESTOR 13. PROVIDE ALL HOLES, SLEEVES AND CAULKING CAULKING FOR INSTALLATION OF OF THIS WORK. CAULKING TO CONFORM CONFORM TO TO FIRE FIRE RATING OF OF WALLS. 14. PIPING SHALL BE ABOVE CEILING AND CLEAR ANY EXISTING PIPING, LIGHTING FIXTURES, DUCTS, DUCTS, ETC. ETC. 15. RUN NEW WASTE PIPES AS CLOSE AS POSSIBLE TO UNDERSIDE OF FLOOR SLAB AND VENT PIPING PIPING AS CLOSE AS POSSIBLE TO SLAB ABOVE. 16. CONTRACTOR SHALL SUBMIT SKETCH TO THE STRUCTURAL ENGINEER FOR APPROVAL, PRIOR TO MAKING REQUIRED BEAM PENETRATIONS. 17. DISRUPTION OF ANY EXISTING SERVICE SHALL BE COORDINATED WITH THE OWNER AND SHALL SHALL BE PERFORMED PERFORMED AT AT A TIME AND MANNER MANNER SO SO AS TO CAUSE CAUSE THE THE OWNER OWNER A A MINIMUM OF INCONVENIENCE. 18. FOR EXACT LOCATION OF PLUMBING FIXTURES, REFER TO ARCHITECTURAL PLANS AND ELEVATIONS. 19. SIZES AND ROUTING OF EXISTING PIPING ARE BASED ON AS-BUILT DRAWINGS PROVIDES BY CITY OF GAITHERSBURG. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND SHALL REPORT CONSISTENCY CONSISTENCY TO TO AE AE PRIOR PRIOR TO TO START START OF OF WORK. 20. CONTRACTOR SHALL LOCATE NEW SANITARY (2%SLOPE) AND VENT PIPING TO GREASE INTERCEPTOR TO ENSURE THAT THAT THE THE INVERT INVERT OF OF EXISTING PIPING (THAT NEED TO BE CONNECTED) CONNECTED) ARE ARE MAINTAINED. MAINTAINED. EXAMINATION EXAMINATION OF OF EXISTING EXISTING CONDITIONS: CONDITIONS: 1. PRIOR TO BID VISIT VISIT AND AND CAREFULLY CAREFULLY EXAMINE EXAMINE THOSE THOSE PORTIONS OF THE PRESENT BUILDING AFFECTED BY THIS WORK SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND OF THE WORK BEFORE SUBMITTING DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF PROPOSALS. 2. SUBMISSION OF A PROPOSAL WILL BE CONSTRUCTED AS EVIDENCE THAT SUCH EXAMINATION HAS HAS BEEN BEEN MADE MADE AND AND LATER LATER CLAIMS CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS EXAMINATION REQUIRED BECAUSE DIFFICULTIES ENCOUNTERED, WHICH COULD, HAVE BEEN FORESEEN HAD EXAMINATION HAD HAD BEEN BEEN MADE, MADE, WILL WILL NOT BE RECOGNIZED SUCH AN EXAMINATION Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 No. Description Date CONNECTION WORK: CONNECTION TO TO EXISTING EXISTING WORK: EXISTING WORK TO INSURE MINIMUM 1. PLAN INSTALLATION OF NEW WORK AND CONNECTIONS TO EXISTING REGULAR OPERATION OPERATION OF OF EXISTING EXISTING FACILITIES. FACILITIES. INTERFERENCE WITH REGULAR 2. SUBMIT TO THE OWNER FOR APPROVAL, APPROVAL, DATE SCHEDULE OF NECESSARY TEMPORARY SHUTSHUT-DOWNS SHALL SHALL BE BE MADE AT SUCH SUCH TIMES TIMES AS WILL NOT DOWN OF EXISTING SERVICES. ALL SHUT-DOWNS OPERATING OF OF EXISTING EXISTING FACILITIES FACILITIES AND ONLY AFTER WRITTEN INTERFERE WITH REGULAR OPERATING APPROVAL OF OF OWNER. OWNER. APPROVAL Revisions Drawing Title PLUMBING GENERAL NOTES, ABBREVIATIONS AND SYMBOLS 3. TO INSURE CONTINUOUS OPERATION, MAKE NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. Phase 4. CONNECT NEW WORK TO EXISTING WORK IN A NEAT NEAT AND APPROVED MANNER. RESTORE EXISTING EXISTING WORK DISTURBED DISTURBED TO TO ORIGINAL CONDITION. CONCEPT A/E Project Number 12-0009.015 Date 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By RP Checked By AK Sheet 1:1 Number P001 SCALE: 1-1/2" 1-1/2" = = 1'-0" 1'-0" SCALE: 2' 1' 0 SCALE: 1" = 1'-0" 1'-0" SCALE: 1" = 1' 2' KITCHEN KITCHEN 11 P400 P400 1B 1B 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: SCALE: 3/4" 3/4" = = 1'-0" 1'-0" UP UP SCALE: 1/2" SCALE: 1/2" = = 1'-0" 1'-0" UP UP SCALE: 1/4" SCALE: 1/4" = = 1'-0" 1'-0" Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 UP UP SCALE: SCALE: 3/16" 3/16" = = 1'-0" 1'-0" No. Description Date TOILET TOILET 33 STORAGE STORAGE SCALE: SCALE: 1/8" 1/8" = = 1'-0" 1'-0" 0 4' 8' 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 1' 3' 11 2' 0 1/2' LOADINGDOCK DOCK LOADING 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 NIKA A+E 44 22 P400 P400 Revisions CONFERENCE CONFERENCE 22 Drawing Title SCOPE OF OF WORK WORK SCOPE PLUMBING FIRST FLOOR OVERALL PLAN - DEMOLITION Phase 32' CONCEPT A Project Number A/E 12-0009.015 SCALE: SCALE: 1/16" 1/16" = = 1'-0" 1'-0" 8' 16' D Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION 11 P100 P100 SS FIRSTFLOOR FLOOR OVERALL OVERALL PLAN-PLUMBING PLAN-PLUMBING DEMOLITION DEMOLITION FIRST 3/16"==1'-0" 1'-0" 3/16" 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W W NN CADD Plot Scale Revit Model Drawn By RP Checked By AK Sheet EE 100% 1:1 Number P100 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' SCALE: 1" = 1'-0" 1' 0 1/2' LOADING DOCK DOCK LOADING 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 11 P401 P401 1B 1B KITCHEN KITCHEN 11 3' DW DW NIKA A+E 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com SCALE: 3/4" = 1'-0" SCALE: 1/2" = 1'-0" UP UP SCALE: 1/4" = 1'-0" Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 UP UP SCALE: 3/16" = 1'-0" No. TOILET TOILET 33 Description Date Room Room 15 15 22 P401 P401 16' 0 4' 8' 12' 0 2' 4' 8' 0 1' 2' 4' 0 1' 2' UP UP STORAGE STORAGE SCALE: 1/8" = 1'-0" 0 4' 8' 44 CONFERENCE CONFERENCE 22 Room Room Revisions 13 13 Drawing Title SCOPE OF WORK PLUMBING FIRST FLOOR OVERALL PLAN Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION 11 P101 P101 FIRST FLOOR FLOOR OVERALL OVERALL PLAN-PLUMBING PLAN-PLUMBING FIRST S S 3/16" 3/16" == 1'-0" 1'-0" 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 W W N N CADD Plot Scale Revit Model Drawn By RP Checked By AK Sheet E E 100% 1:1 Number P101 SCALE: 1-1/2" = 1'-0" 2' 1' 0 2' (E) 1/2" 1/2" CW CW & & HW HW ABOVE THE CEILING HW 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 (E) 1 1/4" 1/4" CW CW & & HW HW IN THE CEILING SCALE: 1" = 1'-0" 0 1/2' 1' CW CW HW 1 1/4"ø 1 1/4"ø 1 1/4"ø (E) FLOOR DRAIN TO REMAIN 1 1/2"ø 1/2"ø 3' 1/2"ø 2' 4"ø SCALE: 3/4" = 1'-0" 1' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com (E) 3" 3" VENT VENT UP 4"ø 4"ø 4"ø 4"ø 1/2"ø 1/2"ø (E) 1/2" CW & HW IN THE CEILING 4' 0 NIKA A+E 4"ø SCALE: 1/2" = 1'-0" 1 P400 KITCHEN ENLARGED PLAN-PLUMBING DEMOLITION 3/8" = 1'-0" SCALE: 1/4" = 1'-0" 0 2' 4' 8' 0 1' 2' CAP AS REQUESTED UNDER THE FLOOR 1 1/2"ø 1 1/2"ø 4"ø LV-(E) 12' WC-(E) SCALE: 3/16" = 1'-0" 8' 4' (E)WASHER/DRYER TO BE RELOCATED No. Description Date Revisions SCALE: 1/8" = 1'-0" 0 4' 8' 16' 0 3/4"ø 3/4"ø 1 1/2"ø Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 2"ø 2"ø 1 1/2"ø (E)3" (E)3" VENT VENT UP Drawing Title SCOPE OF WORK PLUMBING FIRST FLOOR ENLARGED PLANS DEMOLITION Phase 32' CONCEPT A Project Number A/E 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' D Date 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CASEY COMMUNITY CENTER INTERIOR RENOVATION S 35% 60% 90% Drawing Scale: AS NOTED CADD Filename 07-15-15 22 P400 APARTMENT AND AND BATHROOM BATHROOM ENLARGED ENLARGED PLAN-PLUMBING PLAN-PLUMBING DEMOLITION DEMOLITION APARTMENT W 3/8" = 1'-0" N CADD Plot Scale Revit Model Drawn By RP Checked By AK Sheet E 100% 1:1 Number P400 2' SCALE: 1-1/2" = 1'-0" 1' 0 3"ø 3"ø 1% 1%SLOPE SLOPE 4"ø 4"ø 2' RE-CONNECT RE-CONNECT THE THE NEW NEW SINK SINK WITH WITH EXISTING EXISTINGPIPING. PIPING. 3' 3"ø 3"ø CO CO CO CO 3/4"ø 3/4"ø 2"ø 2"ø CW CW NIKA A+E 2"ø 2"ø 2"ø 2"ø FD-1 FD-1 2"ø 2"ø SCALE: SCALE:3/4" 3/4"= =1'-0" 1'-0" 4"ø 4"ø (E) (E) CW CW && HW HW IN IN THE CEILING THE CEILING 4"ø 4"ø 2"ø 2"ø KS-1 KS-1 111/2"ø 1/2"ø CO CO FS-1 FS-1 SS-1 2"ø 2"ø CO CO CW CW 3/4"ø 3/4"ø CW CW HW HW SS-1 DW DW 111/2"ø 1/2"ø 4' 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 4"ø 4"ø CW CW CW CW 3/4"ø 3/4"ø CW CW HW HW HW HW DRAIN DRAINPIPE PIPEABOVE ABOVETHE THEFLOOR. FLOOR. REFER TO RISE DIAGRAM REFER TO RISE DIAGRAM REUSE EXISTING CW && HW REUSE EXISTING CW HW TO SERVE THE NEW THREE TO SERVE THE NEW THREE COMPARTMENT SINK COMPARTMENT SINK SCALE: SCALE:1/2" 1/2"= =1'-0" 1'-0" FD-(E) FD-(E) 4"ø 4"ø 2' 1' EMERGENCY EMERGENCYFLOOR FLOOR DRAIN. DRAIN.VERIFY VERIFYEXACT EXACT LOCATION LOCATIONIN INFIELD FIELD 3"ø 3"ø 3/4"ø 3/4"ø 0 CO CO 4"ø 4"ø 3"ø 3"ø (E) (E) 3" 3" VENT VENT PIPE PIPE 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 4"ø 4"ø 1% 1%SLOPE SLOPE ICE ICE MAKER MAKER CW CW 3/4" DRAIN SERVES 3/4" DRAIN SERVES THE THE ICE-MAKER. ICE-MAKER. All All CONNECTIONS CONNECTIONS TO TO THE THE MACHINE MACHINE WILL BE PROVIDED PROVIDED BY WILL BE BY OTHERS OTHERS FD-1 FD-1 11 1/4"ø 1/4"ø 1/2" COLD WATER LINE TO THE THE ICEICEMAKER. All CONNECTIONS CONNECTIONS TO TO THE THE MACHINE MACHINE WILL WILL BE PROVIDED BY OTHERS OTHERS 1% SLOPE SLOPE 1% 1% SLOPE SLOPE 1% SCALE: SCALE: 1" 1" = = 1'-0" 1'-0" 1' 0 1/2' 11 1/4"ø 1/4"ø 11 1/4"ø 1/4"ø HS-1 HS-1 CW CW HW HW PROVIDE PROVIDEFLOW FLOWCONTROL CONTROLWITH WITHAIR AIR INTAKE. INTAKE.REFER REFERTO TODETAILS DETAILS 4"ø 4"ø CW CW HW HW DRAIN FOR FOR ICEMAKER ICEMAKER 2' CASEY COMMUNITY CENTER INTERIOR RENOVATION CO CO CAP CAP 1' CO CO CO CO 1% 1%SLOPE SLOPE (E) 1 1/2" CW & HW HW IN THE THE CEILING CEILING 0 GI-1 GI-1 CO CO (E) (E) 1/2" 1/2" CW CW & & HW HW IN IN THE THECEILING CEILING DW-1 DW-1 HIGH HIGHTEMPERATURE TEMPERATUREDISHWASHER DISHWASHER WITH WITHBUILT-IN BUILT-INBOOSTER BOOSTERHEATER HEATER 2" 2"DRAIN DRAINPIPE PIPEFROM FROM DISHWASHER DISHWASHER 33COMPARTMENT COMPARTMENTKITCHEN KITCHENSINK SINKKS-1 KS-1 DISCHARGED DISCHARGEDTHROUGH THROUGHINDIRECT INDIRECTDRAIN DRAININ INFS-1 FS-1 11 P401 P401 KITCHEN ENLARGED KITCHEN ENLARGED PLAN-PLUMBING PLAN-PLUMBING 3/8" 3/8" = = 1'-0" 1'-0" 2" OPEN SITE DRAIN 8' BWV-1 1/2"ø 1/2"ø (E)3" (E)3" VENT VENTUP UP 4"ø 4"ø SCALE: SCALE:1/4" 1/4"==1'-0" 1'-0" HW 1/2"ø CW CW HW 2 " PIPE BELOW SLAB PIPES ABOVE CEILING 2" OPEN SITE DRAIN HW CW CW 4"ø 4"ø 2"ø 2"ø Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 LV-1 LV-1 WC-1 WC-1 4"ø 4"ø CAP CAPPIPING PIPINGBACK BACK TO TOTHE THEWALL WALL (E) (E)FD FD 2 " PIPE BELOW SLAB WASHER & DRYER HW HW CW CW 221/2"ø 1/2"ø 1/2" PIPES ABOVE CEILING RE-CONNECT RE-CONNECTNEW NEW FIXTURES FIXTURESWITH WITH EXISTING EXISTINGPIPES PIPES WASHER & DRYER 3 3 P501 P501 VB-1 SCALE: SCALE:3/16" 3/16"==1'-0" 1'-0" 2"ø 2"ø HW HW CW CW 1/% SLOPE 1/2"ø 12' 8' 4' 1/2"ø 1/2"ø 2"ø BWV-1 (E) (E) BELOW BELOW FLOOR FLOOR 111/4"ø 1/4"ø 1 1/4"ø 1 1/4"ø CO CO 1 1/4"ø 1 1/4"ø 1 1/4"ø 1 1/4"ø CD CD No. CO CO 1 1/4"ø 1 1/4"ø 1 1/4"ø 1 1/4"ø 16' 0 VB-1 1/% SLOPE HW CW 0 2' 4' 2 " PIPE ABOVE GROUND 1 1/4"ø 1 1/4"ø Description Date PROVIDE DIRECT PROVIDE DIRECT CONNECTION TO THE CONNECTION TO THE CEILING CASSETTE. CEILING CASSETTE. REFER TO MECH DWG REFER TO MECH DWG FOR CONTINUATION. FOR CONTINUATION. (TYPE OF 5) (TYPE OF 5) SCALE: SCALE:1/8" 1/8"==1'-0" 1'-0" Revisions CONDENSATE DRAIN CONDENSATE DRAIN DISCHARGE ABOVE GROUND. DISCHARGE ABOVE GROUND. CD CD CD CD ROUTE CONDENSATE ROUTE CONDENSATE DRAIN PIPE ABOVE DRAIN PIPE ABOVE CEILING AND UNDER CEILING AND UNDER ALL DUCTWORKS ALL DUCTWORKS ROUTE CONDENSATE ROUTE CONDENSATE DRAIN PIPE ABOVE DRAIN PIPE ABOVE CEILING AND UNDER CEILING AND UNDER ALL DUCTWORKS ALL DUCTWORKS 1 1/4"ø 1 1/4"ø SCOPE SCOPEOF OFWORK WORK Drawing Title PLUMBING FIRST FLOOR ENLARGED PLANS CONDENSATE DRAIN CONDENSATE DRAIN DISCHARGE ABOVE GROUND. DISCHARGE ABOVE GROUND. Phase CONCEPT 32' 0 4' 8' CD CD A/E Project Number SCALE: SCALE:1/16" 1/16"==1'-0" 1'-0" 8' 16' 12-0009.015 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 3" 3"VENT VENTDISCHARGET DISCHARGETOUTSIDE OUTSIDEABOVE ABOVE GROUND. GROUND.REFER REFERTO TORISER RISERDIAGRAM DIAGRAM Date 2 2 P401 P401 APARTMENT AND BATHROOM ENLARGED PLAN-PLUMBING APARTMENT AND BATHROOM ENLARGED PLAN-PLUMBING 3/8" = 1'-0" 3/8" = 1'-0" S S E E W W N N 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By RP Checked By AK Sheet 1:1 Number P401 PLUMBING SCHEDULE PLUMBING FIXTURES FIXTURES SCHEDULE KITCHEN SINK SERVICE SIZE (INCHES) BOWL SIZE (INCH) WIDTH SCALE: 1-1/2" = 1'-0" 0 1' 18 # OF 70% OF VOLUME LENGTH HEIGHT BOWL (CU INCH) 18 14 2' 6,350 FIXTURE TYPE WC-1 WATER CLOSET LV-1 LAVATORY KS-1 28 MOP SINK 3" FLOOR DRAIN 1 3 3 DFU 2 6 12 DFU 1 3 DFU 3 TOTAL GPM PER UPC UPC TABLE 10-2 SCALE: 1" = 1'-0" 1' 0 1/2' 2 VOLUME (GPM) FIXTURE TAG PLUMBING FIXTURE QUANTITY DRANAGE FIXTURE UNITS TOTAL (DFU) PER UPC TABLE 7-3 COMMERCIAL SINK WITH GRINDER 18 GPM BASED ON THE SPECIFIED DISHWASHER CAPACITY 3 GPM GREASE INTERCEPTOR INTERCEPTOR CAPACITY PER IPC TABLE 1003.3.4.1, GREASE RETENTION CAPACITY 49 GPM 100 LB WASTE VENT CW SF 11' - 7 1/2" REMARKS HW 4 2 1 - 1 1/2 1 1/2 1/2 1/2 AMERICAN STANDARD MALL MOUNTED KITCHEN SINK 2 1 1/2 1/2 1/2 T&S BRASS WALL MOUNTED MOUNTED SS WITH THREE BOWLS AND LEFT DRAINBOARD. AERO MODEL F3L SERIES WITH T&S FAUCET MODEL # B-0230 OR EQUAL SS-1 SERVICE SINK 2 1 1/2 1/2 1/2 MOUNTED AMERICAN STANDARD STANDARD FAUCET PROVIDED WITH VACUUM BREAKER, HOSE LIGHT COMMERCIAL WALL MOUNTED WITH WALL MOUNTED THREADS, AND BUCKET HOOK SPOUT. HS-1 HAND SINK 1 1/2 1 1/2 1/2 1/2 WITH FAUCET. FAUCET. ADVANCE ADVANCE TACO MODEL 7-PS-67 OR SMALLER SMALL SIZE BOWL WITH FS-1 FLOOR SINK 2 1 1/2 - - WITH DOME STRAINER, FULL FULL GATE GATE AND AND SEDIMENT SEDIMENT BUCKET BUCKET OR EQUAL LIGHT COMMERCIAL MODEL # 2370 WITH FD-1 FLOOR DRAIN 3 2 - - WITH BALL BALL FLOAT FLOAT TYPE TYPE BACKWATER BACKWATER VALVE VALVE AND INTERNAL CLEANOUTS OR EQUAL URN MODEL # Z742 WITH GI-1 GREASE INTERCEPTOR 3 2 - - WITH EXTENSION, PC/FG # 8250 OR EQUAL JAY R SMITH 8200 SERIES WITH AMERICAN STANDARD FLOOR MOUNTED ADA COMPLIENT VB-1 VALVE BOX 2 1 1/2 1/2 1/2 BWV-1 BACK WATER VALVE 2 - - - DW-1 DISHWASHER 2 1 1/2 - 3/4 SLOPE 1/% CASEY COMMUNITY CENTER INTERIOR RENOVATION KK 1'-6" PROVIDE2' MIN. - 0" DISTANCE FROM THE GROUND RECESSED INTO THE WALL, OATEY MODEL WITH TWO PORTS DESIGNED TO ACCOMMODATE ADDITIONAL DRAIN LINES. OR EQUAL FLAPPER, MIA MODEL B 1000 OR EQUAL CAST IRON BODY WITH PVC FLAPPER, HIGH TEMPERATURE TEMPERATURE SINGLE SINGLE RACK, RACK, CMA-180CB (CORNER LOCATION), LOCATION), ENERGY STAR QUALIFIED. WITH BOOSTER HEATER . ELECTRIC RATING: 3 PHASE, 208 VOLTS AND 45 AMPS OR EQUAL. 33 3' P501 TAG DESCRIPTION SCALE: 3/4" = 1'-0" CAPACITY CONDENSATE PIPE DISCHARGE CONDENSATE PIPE DISCHARGE 3/8" = 1'-0" NIKA A+E BASIS OF DESIGN MANUFACTURER AND MODEL BFP-1 BACKFLOW PREVENTER 1/2" 5 PM @ 11PSI REDUCED PRESSURE PRESSURE ZONE ASSEMBLE ASSEMBLE MODEL MODEL WATTS SERIES 009 OR ECUAL. ECU BFP-2 BACKFLOW PREVENTER 3/4" 13 PM@ 12PSI REDUCED PRESSURE PRESSURE ZONE ASSEMBLE ASSEMBLE MODEL MODEL WATTS SERIES 009 OR ECUAL. ECU 2' 1' 0 SIZE 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 FIRST FLOOR FLOOR FIRST 0' - 0" BLACKFLOW BLACKFLOW PREVENTER PREVENTER SCHEDULE SCHEDULE 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com 1 1/4"ø 1 1/4"ø HW C W 4"ø VENT 3/4"ø 1 1/2"ø THE ROOF C W BWV-1 HW 3/4"ø 2"ø SCALE: 1/4" = 1'-0" HW C 3/4"øW CW 1/2"ø 1 1/2"ø CW HW 1 1/2"ø 1/2"ø 2"ø 1 1/2"ø 1"ø 1"ø HW 2"ø HW 1/2"ø CW HW CW CW HW 3/4"ø 2"ø 3/4"ø 1"ø 1"ø 3/4"ø SCALE: 3/16" = 1'-0" 1"ø 1"ø 4"ø 1/2"ø HW HS-1 3/4"ø HW 3/4"ø CW KS-1 FD-1 3"ø CO 1 1/2"ø LV-1 1/2"ø CAP PIPING BACK TO THE WALL 1/2"ø (E) SAN PIPE 4"ø SLAB UNDER (E) FD TO REMAIN 4"ø 4"ø CAP PIPING BACK TO THE WALL CO HW CW (E) EMERGENCY BFP-2 FLOOR DRAIN 2"ø 1 1/2"ø (E) FD TO REMAIN CO2"ø 16' FS-1 2"ø DW-1 CW 4"ø 4"ø 4"ø 3/4"ø 4"ø SCALE: 1/8" = 1'-0" 8' 4' 0 4"ø GI-1 UNDERGROUND CO PROVIDE FLOW CONTROL WITH AIR 4"ø INTAKE. REFER TO PLAN & DETAILS 3/4"ø 4"ø 4"ø 3/4"ø 2"ø SS-1 PROVIDE FLOW CONTROL WITH AIR INTAKE. REFER TO PLAN & DETAILS Revisions Drawing Title PLUMBING RISER DIAGRAMS AND SCHEDULE 4"ø 2"ø Phase 32' CONCEPT A/E Project Number 12-0009.015 SCALE: 1/16" = 1'-0" 8' 16' Date 1 P501 RISER DIAGRAM-APARTMENT PLUMBING RISER DIAGRAM-APARTMENT NEW WORKNEW WORK 1 PLUMBING P501 22 PLUMBING PLUMBING RISER RISER DIAGRAM-KITCHEN DIAGRAM-KITCHEN NEW NEW WORK WORK Date CO 4"ø CO 4"ø 4"ø UNDERGROUND SS-1 3/4"ø 4"ø 4"ø CO Description CO 3/4"ø 4"ø DW-1 No. CO 4"ø BFP-2 2"ø GI-1 2"ø CO CO 2 1/2"ø Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 4"ø HW 4"ø 2"ø 4"ø 3/4"ø 3/4"ø 2"ø 4"ø CAP PIPING BACK TO THE FLOORCAP PIPING BACK TO THE FLOOR 4"ø 2 1/2"ø 3"ø 3"ø FS-1 4"ø CO 3/4"ø FD-1 3/4"ø 3/4"ø 2"ø CO (E) EMERGENCY FLOOR DRAIN FD-1 4"ø WC-1 (E) SAN PIPE UNDER SLAB 3"ø 3/4"ø HW 3/4"ø 1 1/2"ø FD-1 CO 1 1/2"ø 4"ø 4"ø CW CW KS-1 1"ø 1/2"ø 4"ø 1/2"ø 3/4"ø 3/4"ø 1"ø CW CW 12' 0 4' 8' 2"ø 3" VENT DISCHARGET OUTSIDE ABOVE GROUND. REFER TO RISER DIAGRAM HS-1 1"ø CW 1/2"ø 3" VENT DISCHARGET OUTSIDE ABOVE GROUND. REFER TO RISER DIAGRAM 1"ø 2"ø 4"ø PROVIDE WATER HAMMER ARRESTOR TYP "A" PROVIDE WATER C HAMMER ARRESTOR TYPW"A" HW CW 4"ø 1/2"ø 1/2"ø WASHER/DRYER 1"ø 1"ø 1/2"ø CW HW 3/4"ø CW CW HW CW 1/2"ø PROVIDE VB-1 and BWV-1. REFER TO PLAN FOR LOCATION 2"ø ICE MAKER 3/4"ø C W HW HW 8' 4' 2' CW 1/2"ø WASHER/DRYER 0 4" VENT PIPE CONTINUES TO THE ROOF 1/2"ø 1/2"ø ICE MAKER HW 2"ø 4" VENTH PIPE W CONTINUES TO1 1/2"ø CW CW CW HW BFP-1 1 1/4"ø HW CW 1/2"ø 2"ø HW 1 1/2"ø HW CW 1/2"ø CW CW 1/2"ø 1/2"ø 1 1/4"ø 1/2"ø PROVIDE VB-1. PROVIDE REFERHAMMER TO PLAN ARRESTOR TYP "A" FOR LOCATION CW CW PROVIDE HAMMER ARRESTOR TYP "A" 1 1/4"ø 1 1/4"ø HW CW 1 1/4"ø 1/2"ø 1 1/4"ø HW C W BFP-1 CW CW SCALE: 1/2" = 1'-0" 0 1' 2' 4' 4"ø VENT CW 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED 2' GREASE CALCULATIONS GREASE INTERCEPTOR INTERCEPTOR CALCULATIONS 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By RP Checked By AK 1:1 P501 Sheet Number P501 2' FLOOR CLEANOUT CLEANOUT UNIT FLOOR CLEANOUT CLEANOUT COVER CSK SCREW CLEANOUT CLEANOUT PLUG PLUG SCALE: 1-1/2" = 1'-0" 2" 2" 6" 6" SCALE: 1" = 1'-0" CLAMP PAN CLAMP PAN TIGHTLY TIGHTLY INTO DRAIN COLLAR INTO DRAIN COLLAR DRAIN DRAIN BODY BODY POURED POURED IN IN PLACE PLACE FLOOR CLEAN OUT DETAIL FLOOR DRAIN DETAIL 2 NTS P601 P601 INSULATION (VAPOR BARRIER BARRIER TYPE TYPE IS IS REQUIRED REQUIRED FOR FOR LOW LOW TEMPERATURE TEMPERATURE PIPE) PIPE) 4 NTS P601 DEEP FLOOR PENETRATION CLEAN OUT DETAIL NTS SCALE: 3/4" = 1'-0" PROVIDE HIGH COMPRESSIVE STRENGTH INSULATION INSULATION UNDER UNDER INSULATION SHIELD SHIELD WELD INSULATION INSULATION SHIELD SHIELD AT AT HANGER SADDLE ADJUSTABLE CLEVIS HANGER SEE SPECIFICATIONS SPECIFICATIONS FOR FOR MAX. MAX. SUPPORT SPACING) A FIXTURE UNIT RATING CONCEAL CONCEAL IN CEILING SPACE TO TO ELIMINATE ELIMINATE ACCESS PANELS 1-11 B C 12-32 33-60 D 61-113 E F 114-154 155-330 FINISHED WALL BACK-SPLASH CARRIER STAINLESS STAINLESS STEEL BELLOWS UNDER NORMAL NORMAL CONDITIONS WATER HAMMER ARRESTOR PDI SYMBOL SUPPLY RISER BEARING PLATE PDI "A" BALL VALVE LAVATORY 12" BAND 1-5/8" 12 GAUGE GAUGE CHANNEL CHANNEL OR OR 2"x2"x1/4" 2"x2"x1/4" ANGLE 1" MAX. PDI SYMBOL 451 HUNGERFORD DRIVE (P)301.770.3520 4TH FLOOR (F)301.770.3521 ROCKVILLE, MD 20850 www.nika-ae.com BELLOWS EXPANDED UNDER SHOCK PRESSURE ADJUSTABLE ADJUSTABLE CLEVIS HANGER HANGER SEE SPECIFICATIONS SPECIFICATIONS FOR FOR MAX. MAX. SUPPORT SPACING) SPACING) PROVIDE INSULATION SHIELD & INSERT FOR FOR ALL ALL PIPING PIPING (8" (8" MIN.) MIN.) SCALE: 1/2" = 1'-0" PDI (PLUMBING AND DRAINAGE INSTITUTE WATER HAMMER ARRESTER STAINLESS STAINLESS STEEL STEEL CASING 1/2" DIA. HANGER RODS WITH 36" MAX. SPACING ON EACH CHANNEL NOTES: NOTES: SEE SPECIFIER FOR DETAILED HANGER REQUIREMENTS REQUIREMENTS NIKA A+E WATER WATER HAMMER HAMMER ARRESTOR ARRESTOR SCHEDULE SCHEDULE 1/2" CW & HW SUPPLIES WITH STOP. INSULATE CW & HW SUPPLIES. TYPICAL BRANCH LINE NOTES: 1. INSTALLATION OF WATER HAMMER ARRESTORS SHALL BE AT THE END OF BRANCH ARRESTORS LINE BETWEEN THE LAST TWO FIXTURES SERVED. SUPPLY WATER PIPING 1 1/2" 1/2" WASTE WASTE & "P" "P" TRAP TRAP INSULATED MAXIMUM MAXIMUM PIPE/TUBING PIPE/TUBING SUPPORT SUPPORT BRACING BRACING SCALE: 1/4" = 1'-0" THRU THRU 3/4 3/4 11 11 1/4 1/4 1 1/2 PIPE FT. FT. 7 77 77 TUBING TUBING FT. FT. 5 66 77 22 2 1/2 3 44 55 66 8 99 10 10 11 11 12 14 14 16 16 17 19 88 88 99 10 12 12 13 13 14 16 PIPEING HANGER DETAIL WATER HAMMER ARRESTER DETAIL 6 NTS P601 7 NTS P601 VENT PIPE PIPE DISCHARGE DISCHARGE IN EXTERIOR BIRD PROTECTION PROTECTION AT WALL. PROVIDE BIRD THE OUTSIDE TERMINATION SCALE: 3/16" = 1'-0" FINISHED FLOOR 3. THE SUM OF OF FIXTURE FIXTURE UNIT RATING OF UNITS OVER 20' IN LENGTH SHALL BE EQUAL TO OR GREATER THAN THE THE DEMAND OF THE THE BRANCHES. NOTE: NOTE: FOR FOR TRAPEZE TRAPEZE HANGER HANGER TAKE TAKE SPACING SPACINGOF OF SMALLEST SMALLEST SIZE SIZE ON TRAPEZE. TRAPEZE. 5 BLOCK BASE PLATES 2. ONE WATER HAMMER ARRESTOR ARRESTOR PER 20' LINE, AND ANOTHER ANOTHER FOR FOR BRANCHES BRANCHES OVER 20' IN LENGTH. 12' 8' 4' 0 WALL SUPPORT PIPING DETAIL 3 NTS VENT VENT PIPE PIPE CONNECTED AT EXISTING. EXISTING. REFER TO THE THE PLAN PLAN PIPING PIPING LAYOUT. LAYOUT. TYPICAL LAVATORY (HS-1) CARRIER DETAIL NTS Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland. License number 24152, Expiration date 03.19.2017 No. Description Date NON-SKID COVER 3" GREESE INTERCEPTOR VENT 16' 2" FLOW CONTROL VENT SCALE: 1/8" = 1'-0" 8' 4' FRONT VIEW SIDE VIEW HANGER HANGER ROD P601 P601 0 UNISTRUT CHANNEL WITH PIPE CLIPS EXPANSION SHIELD (MINIMUM) 1' 0 2' 1' 1 P601 P601 2' 1' 0 CONCRETE CONCRETE FLOOR SLAB FLOOR SLAB CASEY COMMUNITY CENTER INTERIOR RENOVATION 810 S FREDERICK AVE, GAITHERSBURG, MD 20877 3' 0 1/2' FLOW FLOW 4' 2' 1' 0 CONCRETE SLAB PIPE WITH PROTECTIVE COATING LEAD LEAD AND AND OAKUM OAKUM OR OR NEOPRENE NEOPRENE GASKET GASKET 8' 4' 2' 0 WATER PROOF PROOF WATER MEMBRANE MEMBRANE SLOPE DRAIN SLOPE TO TO DRAIN CAULKING CAULKING FERRULE FERRULE NOM. NOM. SIZE SIZE IN. IN. 4" MIN. MIN. SPECIFY SPECIFY EXTENSION HEIGHT REQUIRED CLEAN-OUT KS-1 Revisions LOCK AND LIFT RING Drawing Title 4" NO-HUB OUTLET PLUMBING DETAILS 4" NO-HUB NO-HUB INLET INLET 32' AIR RELIEF RELIEF CO 1% SLOPE REMOVEABLE BAFLERS 8 P601 P601 GREASE INTERCEPTOR DETAIL NTS FLOW CONTROL WITH INTAKE AIR 1% SLOPE STATIC STATIC WATER WATER LINE LINE SCALE: 1/16" = 1'-0" 16' TOPPING CERAMIC CERAMIC TILE TILE AND SETTING BED AND SETTING BED FINISHED FINISHED FLOOR FLOOR SURFACE SURFACE SIDE VIEW TRAPEZE HANGER FOR UP TO 1000 LB. UNIFORM LOAD 8' STAINLESS STEEL MESH PIPE WITH INSULATION FLOOR FLOOR DRAIN DRAIN STRAINER STRAINER FINISHED FINISHED FLOOR FLOOR 0 IF THIS DRAWING IS A REPRODUCTION, GRAPHIC SCALE MUST BE USED CONCRETE SURFACE OR FLOOR COVERING AS REQUIRED FS-1 9 P601 Phase CO CONCEPT 4" PROVIDE EXTENSION FLOOR TO RICH THE FLOOR ELEVATION. MIN 4" ELEVATION. ALWAYS REQUIRED A/E Project Number 4" GI-1 KITCHEN SINK (KS-1) DRAIN PIPE CONNECTIONS DIAGRAM NTS CO 12-0009.015 Date DISCHARGES AT EXISTING SANITARY LINE UNDER SLAB 35% 60% 90% 100% Drawing Scale: AS NOTED CADD Filename 07-15-15 CADD Plot Scale Revit Model Drawn By RP Checked By AK Sheet 1:1 Number P601