Technical Data Sheet25 Pair Category 3 Plenum 2833 West Chestnut Street Washington, PA 15301 Toll Free: (800) 245-4964 Fax: (724) 222-6420 www.westpenn-wpw.com PART NUMBER: WP56801 DESCRIPTION: 24 AWG.- 25 PAIR Solid bare copper conductors, unshielded with an overall jacket. NEC RATING: CMP APPROVALS: (UL) C(UL) Listed or c(ETL)us Listed APPLICATION: Indoor Plenum - Category 3 Applications- Voice – Low Speed Data Construction Parameters: Conductor Stranding Number of Conductors Insulation Shield Drain Jacket Material Overall Cable Diameter Approximate Cable Weight Flame Rating 24 AWG Bare Copper Solid 50 (25 Pair) Plenum Thermoplastic None None Plenum PVC 0.364'' Nom. 108 Lbs/1M' Nom. NFPA 262 Electrical & Environmental Properties: Operating Temperature Rating Operating Voltage Rating DC Resistance per Conductor @ 20deg C Mutual Capacitance Nominal Impedance Velocity of Propogation Delay Skew Standards Insulation Colors 1- White/Blue- Blue/White 14- Black/Brown- Brown/Black 2- White/Orange- Orange/White 15- Black/Gray- Gray/Black 3- White/Green- Green/White 16- Yellow/Blue- Blue/Yellow 17- Yellow/Orange4- White/Brown- Brown/White Orange/Yellow 5- White/Gray- Gray/White 18- Yellow/Green- Green/Yellow 19- Yellow/Brown6- Blue/Red- Red/Blue Brown/Yellow 7- Red/Orange- Orange/Red 20- Yellow/Gray- Gray/Yellow 8- Red/Green- Green/Red 21- Purple/Blue- Blue/Purple 22- Purple/Orange9- Red/Brown- Brown/Red Orange/Purple 10- Red/Gray- Gray/Red 23- Purple/Green- Green/Purple 11- Black/Blue- Blue/Black 24- Purple/Brown- Brown/Purple 12- Black/Orange- Orange/Black 25- Purple/Gray- Gray/Purple 13- Black/Green- Green/Black -20°C To +60°C 300 V RMS 9.38 Ohms/100m Nom. 20 pf/ft Nominal 100 Ohms+/-15% (1-100Mhz) 64% Nominal 45ns/100m MAX TIA/EIA568-B Jacket Color RoHS Compliant Gray Yes Electrical Specifications: Frequency: MHz Insertion Loss: dB/100m NEXT: dB/100m PS-NEXT: dB/100m PS-ACR: dB/100m RL: dB 1 2.2 50 46 43.8 12 10 6.1 35 52 22.2 12 16 9.9 32 47 16.1 10 Mechanical Properties: Max. Recommended Pull Tension Min. Bend Radius (Install) 130lbf. 3.6” Specification Issue Date: 3/10 This document is the property of West Penn Wire. . The information contained herein is considered Proprietary and not to be reproduced by any means Without written consent of West Penn Wire Standard Lengths are 1000ft. The Jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise.