Technical Data Sheet

advertisement
Technical Data Sheet25 Pair Category 3
2833 West Chestnut Street
Washington, PA 15301
Toll Free: (800) 245-4964
Fax: (724) 222-6420
www.westpenn-wpw.com
PART NUMBER:
WP55700
DESCRIPTION:
24 AWG.- 25 PAIR Solid bare copper conductors, unshielded with an overall jacket.
NEC RATING:
CMR
APPROVALS:
(UL) C(UL) Listed or c(ETL)us Listed
APPLICATION:
Indoor - Category 3 Applications- Voice – Low Speed Data
Construction Parameters:
Conductor
Stranding
Number of Conductors
Insulation
Shield
Drain
Jacket Material
Overall Cable Diameter
Approximate Cable Weight
Flame Rating
24 AWG Bare Copper
Solid
50 (25 Pair)
Thermoplastic
None
None
PVC
0.364'' Nom.
100 Lbs/1M' Nom.
UL 1666
Electrical & Environmental Properties:
Operating Temperature Rating
Operating Voltage Rating
DC Resistance per Conductor @ 20deg C
Mutual Capacitance
Nominal Impedance
Velocity of Propogation
Delay Skew
Standards
Insulation Colors
1- White/Blue- Blue/White
14- Black/Brown- Brown/Black
2- White/Orange- Orange/White
15- Black/Gray- Gray/Black
3- White/Green- Green/White
16- Yellow/Blue- Blue/Yellow
17- Yellow/Orange4- White/Brown- Brown/White
Orange/Yellow
5- White/Gray- Gray/White
18- Yellow/Green- Green/Yellow
19- Yellow/Brown6- Blue/Red- Red/Blue
Brown/Yellow
7- Red/Orange- Orange/Red
20- Yellow/Gray- Gray/Yellow
8- Red/Green- Green/Red
21- Purple/Blue- Blue/Purple
22- Purple/Orange9- Red/Brown- Brown/Red
Orange/Purple
10- Red/Gray- Gray/Red
23- Purple/Green- Green/Purple
11- Black/Blue- Blue/Black
24- Purple/Brown- Brown/Purple
12- Black/Orange- Orange/Black
25- Purple/Gray- Gray/Purple
13- Black/Green- Green/Black
-20°C To +60°C
300 V RMS
9.38 Ohms/100m Nom.
20 pf/ft Nominal
100 Ohms+/-15% (1-100Mhz)
64% Nominal
45ns/100m MAX
TIA/EIA568-B
Jacket Color
RoHS Compliant
Gray
Yes
Electrical Specifications:
Frequency: MHz
Insertion Loss: dB/100m
NEXT: dB/100m
PS-NEXT: dB/100m
PS-ACR: dB/100m
RL: dB
1
2.2
50
46
43.8
12
10
6.1
35
52
22.2
12
16
9.9
32
47
16.1
10
Mechanical Properties:
Max. Recommended Pull Tension
Min. Bend Radius (Install)
130lbf.
3.6”
Specification Issue Date: 3/10
This document is the property of West Penn Wire.
. The information contained herein is considered
Proprietary and not to be reproduced by any means
Without written consent of West Penn Wire
Standard Lengths are 1000ft.
The Jacket is sequentially footmarked.
The information presented here is, to the best of our
knowledge, is true and accurate. However, since
conditions of use are beyond our control, all
recommendations or suggestions are presented
without guarantee or responsibility on our part. We
disclaim all liability in connection with the use of
information contained herein or otherwise.