Switch Firmware Version 8.0.14.13 50948-30 Rev A QLogic Corporation All rights reserved Table of Contents 1 2 3 4 5 6 7 8 9 1 Switch Models Version and Date Changes Bug Fixes Known Issues Additional Information Trademarks Notices Contacting Support Switch Models This document applies to the following switches: 2 QLogic 5800 Switch QLogic 5802 Switch QLogic 3810 Switch Version and Date These release notes describe the changes, fixes, known issues, and release details that apply to QLogic 3810 and QLogic 5800V Series Switch firmware, version 8.0.14.13 that was released in December, 2014. If you intend to use Enterprise Fabric Suite to manage QLogic 5800V Series switches with firmware version 8.0.14.xx, you must use Enterprise Fabric Suite version 8.00.12.07 or later. The QLogic 3810 switch can be managed with the CLI or with the QuickTools graphical user interface. QLogic does not support the use of Enterprise Fabric Suite to manage the QLogic 3810 switch. 3 Changes There were no changes. See Section 4 for bug fixes. Switch Firmware Version 8.0.14.13 Page 1 of 4 4 Bug Fixes The following fixes have been made to the firmware between versions 8.0.14.08 and 8.0.14.13 and between QuickTools versions 8.00.14.03 and 8.00.14.08: PR Number Problem 116414 QuickTools issues a security warning when accessing unsigned resources. 122931 EFS and Performance View applications do not open on the Windows 7 Pro 32bit system from c:\Program Files\QLogic_Corporation\Enterprise_Fabric_Suite directory (default installation folder). 123310 images account password can be changed, causing firmware updates and dump supports to fail. 123456 A QuickTools session is vulnerable to a cross-site scripting attack. 125121 Update QuickTools launch for help 125634 Browser fails to open for QuickTools online help on some systems. 125816 TR mapping using QuickTools between a 5800V switch and Brocade 5100 hangs in the TR mapping manager. 125826 Implicit hard zoning is disabled and none of the zone objects in the active zone sets are HardACL. 126029 Java 7u51 or later is required for 8.00.14. 126391 Java exceptions are encountered when creating TR mappings with a Brocade DCX. 126411 Util application crashes while configuring RADIUS. 126454 OpenSSL ChangeCipherSpec Man-in-the-Middle (MiTM) vulnerability. 126488 Ps command does not show running cim_server. 126496 Update firmware with new detection and launch code to support modern browsers. 126499 CIMServer backtrace errors arise after 15 hours of operation. 126519 QuickTools application hangs. 126523 When using QuickTools to archive a switch, the file extension (xml) is not applied on the first attempt. 126539 CVE-2014-6271: Remote code execution vulnerability on Linux systems through the GNU Bourne-again shell (BASH). 126579 CVE-2014-3566: Padding oracle on downgrading legacy encryption (POODLE) vulnerability in OpenSSL 126598 Update supported SSL certificate types. 126636 Update SSL certificate to 2,048 bits. 126657 Fix intermittent Null pointer exception in Quick tools. Switch Firmware Version 8.0.14.13 Page 2 of 4 5 Known Issues The following table identifies the known issues in firmware version 8.0.14.13 and the QuickTools 8.00.14.08 web applet. PR Number Problem Firmware 15409 You may see sluggish response from the CLI when the switch is in a large fabric (12 or more switches and/or more than 350 devices), and the fabric is being discovered. For example, fabric discovery would occur when adding a new switch to the fabric. Discovering the fabric can take from one to five minutes depending on zoning size and the number of switches. 16756 When upgrading firmware while in maintenance mode, the message WARNING: This key is not certified with a trusted signature ... appears. This message is incorrect and should be ignored. 17650 When running internal port loopbacks on a QLogic 5800V/5802V switch, intermittent failures may be seen when inter-switch links are present. The workaround is to put the switch in diagnostic mode, or to remove the inter-switch links. The switch may have difficulty communicating with the DHCPv6 server with certain options enabled. The following lines in the server.conf file on the DHCPv6 server host should be commented out: 24439 109351 # # # # # # # # # provide VoIP parameter (SIP protocol servers and domain names) option sip-server 2000::300,2000::302,2000::303,2000::304 option sip-domain sip1.example.com,sip2.example.com provide NIS information (server addresses and domain name) option nis-server 2000::400,2000::401,2000::404,2000::405,2000::405 option nis-domain nis.example.com provide NIS+ information (server addresses and domain name) option nis+-server 2000::501,2000::502 option nis+-domain nisplus.example.com If QLogic 5800VSeries Switches are configured in a stack with cascading 10G ISLs (only one ISL between each switch), an Emulex 8G adapter (LP 1200x) running traffic can experience a timeout when a stack NDCLA or hot reset is performed using Enterprise Fabric Suite. If the 10G ISL configuration follows QLogic best practices, the timeout does not occur. For information about best practices and stacking, see the Stacking section of QLogic 5800V Series Stackable Fibre Channel Switch Installation Guide, firmware version 8.0). QuickTools 10750 While running QuickTools, if the IP address of the entry switch is changed, online help not will open. To access the online help, close the current QuickTools session, and then reopen QuickTools using the new IP address. 15438 You may see sluggish response from QuickTools when the switch is in a large fabric (12 or more switches and/or more than 350 devices), and the fabric is being discovered. For example, fabric discovery would occur when adding a new switch to the fabric. Discovering the fabric can take from one to five minutes depending on zoning size and the number of switches. 16999 When a new fabric is added, the Fabric Status bar may incorrectly show a warning condition related to Nicknames differ. This warning goes away when the fabric is fully discovered, and nickname conflicts between switches are resolved. 18183 To open the online help in QuickTools on a Mac OS platform, the default browser must be set to a browser other than the one used to open QuickTools. Switch Firmware Version 8.0.14.13 Page 3 of 4 PR Number 20291 6 Problem When using the Firefox 2.0 browser with Solaris10, and opening and closing help windows from the dialog boxes, the following message may be displayed: Firefox is already running but is not responding. To open a new window, you must first close the existing Firefox process or restart your system. If this occurs, follow the instructions to continue opening help windows. Additional Information Read the following document files for more information: 7 readme_firmware_8.0.14.13.pdf Trademarks Accelera, Accelerating Cluster Performance, FastFabric, InfiniCon Systems, InfiniNIC, InfiniPath, InfiniView, Intelligent NIC, Networking University, NetXen, QLogic, the QLogic logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of QLogic Corporation. To the extent a name or logo does not appear on this list does not constitute a waiver of any and all intellectual property rights that QLogic Corporation or its subsidiaries has established in any of its product, feature, or service names or logos. All other brand and product names are trademarks or registered trademarks of their respective owners. 8 Notices Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document. 9 Contacting Support Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached by the following methods: Web: http://support.qlogic.com E-mail: support@qlogic.com Go to Top © Copyright 2014. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. Switch Firmware Version 8.0.14.13 Page 4 of 4