ALTUS ALTUS ALTUS Altus Classic Center Open Perf 2x4 Technical Specifications 1 2 3 1 2 3 Classic Altus Classic Center Open Perf provides comfortable, even, diffuse light for use ALTUS in private offices, open office areas, upscale retail applications, public circulation CLASSIC areas and classrooms. ALTUS Classic Pr ojec t C at alog N um ber Ty pe • Minimal housing depth allows for easy installation into shallow plenums CTraps la s light s ileaks cand secure diffuser to fixture • Injection molded Light prevent ALTUS • High performance perforated metal diffuser combined with thin inlay produces high efficiencies ALTUS D at e HIGH CONSTRUCTION 3 PERFORMANCE 3/4" deep housing allows for fixture installation in shallow plenums. End caps interlock into channel to form sturdy HIfixture GH Housing. Two KOs per end and large access plate in channel simplifyE wiring. End PERF ORMANC caps include integral grid locking feature and four auxiliary mounting points. Die HIGH formed post painted reflectors are easily removable for room side ballast access. Post painted PERFORMANCE open perforated steel diffuser backed with high transmission 3 3/4” inlay is held in place with injection molded mounting bracket that prevent light leaks and allow diffuser to swing down." BALLASTS All supplied fluorescent ballasts are Class P, high power factor, sound rated A, thermally protected, auto resetting, CEE / NEMA Premium compliant unless otherwise specified. All ballasts are fitted with NEC/CEC compliant ballast disconnect. Numerous ballast factor options available for T8 & T5. See "Ballast Technical Sheet" for more information. ALTUS ALTUS CEILING COMPATIBILITY Altus fixtures are compatible with "G" type 9/16" wide & 15/16" Tee lay-in Grid styles. 23 7/8” Also compatible with type "ST" Screw Slots Tees please see illustration. Integral grid lock in end cap secures fixture. Use tie wireACC secured and GCK24 OP 2TT5 CS frame kit for sheet rock ceiling applications. Contact factory for Surface Mounting. OPTICAL SYSTEM Perforated metal with high transmission inlay for exceptional fixture efficiencies. 90%+ reflective, post painted reflectors light evenly and contribute to efficiency and pleasing contrast. 3 3/4” CERTIFICATION All units are built to UL 1598 standards and are labeled C-UL-US Damp location certification 23 7/8” standard. Emergency fixtures are labeled UL924. FINISH All exposed installed surfaces are treated with a multistage, iron phosphate pretreatment and post painted with tough, matte white, polyester, powder coat paint with ACC OP 3T5 CS of 90% reflectivity. a minimum 23 7/8” ACC OP 2T5 CS ELECTRICAL T8 & T5 fixtures use rotolock lamp holders 3 3/4” for securing lamps when fixture is installed or in transit. 3 3/4” 23 7/8” T5 T T T8 L ED T12 23 7/8” T 5 T5 T T T 8 T8 L ED ACC TOPT 3T8 CS T12 3 3/4” 23 7/8” 23 7/8” ACC OL 3T5 CS 3 3/4” 3 3/4” Altus Classic Center Open Perf 2x4 23 7/8” SERIES ACC SACC SIZE 24 = 2’ X 4’ DIFFUSER OP = Open Perforated Metal 3 3/4” LAMPS 2 3 T T 3 3/4” ACC OL 2TT5 CS ACC OL 3T5 CS T 5 8 3T5 CS ACCTOP 23 7/8” 23 7/8” ACC OL 2T5 CS WATTAGE* 32T8 = 32W T8 48” 23 7/8” 28T5 = 24W T5 46” 54T5HO = 54W T5HO 46” 3 3/4” 23 7/8” MADE IN THE UNITED STATES BALLAST** E = Electronic T8 HE = Electronic T5HO PS(x) =T8 only, Program Start (L)= Low BF, (N)= Normal BF, ACD OP 2TT5 CS (H)=High BF HP(x) = T8 only, High Performance (L)= Low BF, (N)= Normal BF, (H)=High BF 3 3/4” ACC OL 3T8 CS SWITCHING VOLTAGE For 2 lamp units: = 120-277V 23U1 7/8” Blank = One 2-lamp ballast 347 = 347V 2/1L = Two 1-lamp ballasts 480 = 480V For 3 lamp units: ACD OP 2T5 CS Blank = One 1-lamp ballast and One 2-lamp ballast 3 3/4” 3L = One 3-lamp ballast 23 7/8” 23 7/8” CS = Customer Supplied ACD OP 2T5 CS *Nominal. See performance data for actual power consumption. 3 3/4” **For exact BF see CEE listing for ballast qualification. B9 = Customer Specified ACD OP 2T5 CS BG ACD OP 2T8 CS 3 3/4” 23 7/8” OPTIONS ACCESSORIES AHPC EL 3T5 CS AR = Air Return GCK24 = Sheetrock/Plaster Grid Kit, 2x4 BP = Bulk Pack, Palletized 3 3/4” 35K = 3500˚K Lamp Installed 41K = 4100˚K Lamp Installed 23 7/8” 23 7/8” ELS1 = Emergency Lighting (T8 500 lm, T5 700 lm) ELS2 = Emergency Lighting (T8 700 lm, T5 700 lm) ELS3 = Emergency Lighting (T8 1400 lm, T5 1400 lm) AHPC ELFL4 2 T5 CS AHPC EL 3T8 CS = Whipped 3/8 6' Flex 2 #18s 3 3/4” FL5 = Whipped 3/8 6' Flex 3 #18s FB = Fast-Blow Fusing 23 7/8” SB = Slow-Blow Fusing (T5 only) M/S = Labor saving Master/Satellite DBG = Debris Guard 23 7/8” AHPC EL 2 T5 CS 3 3/4” 23 7/8” AHPC EL 2T8 CS 3 3/4” 23 7/8” AHPD EL 2TT5 CS AHPD 2T5 CS "AR" not available with "DBG". "DBG" not available with "AR". 3 3/4” 23 7/8” 3 3/4” 23 7/8” FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. AHPD 2T5 CS AHPD 2T8 CS 11052015 REV A 3 3/4” 3 3/4” 23 7/8” (800) 523-3602 • www.simkar.com AHPD LED CS 3 3/4” 3 3/4” Altus Classic Center Open Perf 2x4 Technical Specifications Ceiling Compatibility 15/16" T Grid 9/16" T Grid 9/16" Screw Slot 9/16” 15/16” 1/8” 9/16” Plaster Frame Kit Plaster Frame Kit Ceiling Opening Width Length 1x4 12 - 13 1/2" 48 - 49 1/2 2x2 24 - 25 1/2" 24 - 25 1/2" 2x4 24 - 25 1/2" 48 - 49 1/2 237⁄8” 237⁄8” 117⁄8” 81⁄2” Features 237⁄8” Note: Surface model available. 3”x4” Access Plate Contact factory for more information. 3”x4” Access Plate 2½” 25⁄16” Light Trap 7⁄8” KO TYP 4713⁄16” 4713⁄16” Debris Guard 10¼” 33⁄4” 2½” 1½” Dimensions 3”x4” Access Plate 237⁄8” 237⁄8” 7⁄8” KO TYP 117⁄8” 10¼” 2½” 33⁄4” 1½” 3”x4” Access Plate 20½” 2½” 81⁄2” 25⁄16” 20½” 33⁄8” 2” 7⁄8” KO TYP 33⁄4” 237⁄8” 3”x4” Access Plate 3”x4” Access Plate 2½” 25⁄16” 7⁄8” KO TYP 2½” 83⁄4” 4713⁄16” 4713⁄16” 10¼” 33⁄4” 2½” 1½” 3”x4” Acce Plate 20½” 3”x4” Access Plate 7⁄8” KO TYP 10¼” 2½” 33⁄4” 1½” 2½” 20½” FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11052015 REV A 2” 25⁄16” 7⁄8” KO TYP (800) 523-3602 • www.simkar.com 33⁄4” Altus Classic Center Open Perf 2x4 Technical Specifications Photometric Data Luminaire Data Candela Plot Coefficients of Utilization Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency ACC24OP232T8HPN UL678967 (2) 32W T8 2850 Osram QTP 2/32T8/UNV ISN-SC 0.88 54.37 3,829 67.2% CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 80 73 67 61 56 51 47 43 40 37 34 50 80 70 62 54 48 43 38 34 30 28 25 30 80 68 57 49 43 37 32 28 25 22 19 10 80 65 54 45 38 32 28 24 21 18 16 50 75 66 58 51 46 40 36 32 29 26 24 50 30 75 64 55 47 41 35 31 27 24 21 19 10 75 62 52 44 37 32 27 24 21 18 16 50 71 63 56 50 44 39 35 31 28 25 23 30 30 71 62 53 46 40 35 30 27 24 21 19 180 10 71 60 51 43 37 31 27 23 20 18 15 150 ACROSS 45 ALONG 120 90 400 60 800 Zonal cavity method Effective floor reflectance = 20% 1200 0 Luminance Summary (Candela/M 2 ) Zonal Lumens and Percentages ZONE LUMENS % LAMP % LUMINAIRE ANGLE ALONG 45 ACROSS 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 1000 1650 2962 3829 2179 867 0 3829 17.55 28.95 51.97 67.18 38.23 15.21 0.00 67.18 26.13 43.09 77.36 100.00 56.91 22.64 0.00 100.00 45 55 65 75 85 1493 1390 1224 892 541 1811 1776 1798 1783 826 2070 2150 2311 1615 855 30 S/MH: 1.4 SC(ALONG): 1.2; SC(ACROSS): 1.4 Photometric Data Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency Candela Plot Coefficients of Utilization Luminaire Data ACC24OP332T8HPN UL678969 (3) 32W T8 2850 Osram QTP 3/32T8/UNV ISN-SC 0.88 79.9 5,189 60.7% CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 72 66 61 55 51 46 43 39 36 33 31 50 72 64 56 49 44 39 35 31 28 25 23 30 72 61 52 45 39 33 29 26 23 20 18 10 72 59 49 41 35 29 25 22 19 16 14 50 67 60 53 47 41 37 33 30 27 24 22 50 30 67 58 50 43 37 32 28 25 22 19 17 10 67 56 47 40 34 29 25 22 19 16 14 50 65 57 51 45 40 35 32 29 26 23 21 30 30 65 56 48 42 36 31 28 25 22 19 17 180 10 65 55 46 39 34 28 25 21 19 16 14 150 120 ACROSS 45 ALONG 90 600 60 1200 Zonal cavity method Effective floor reflectance = 20% 1800 0 Luminance Summary (Candela/M 2 ) Zonal Lumens and Percentages ZONE LUMENS % LAMP % LUMINAIRE ANGLE ALONG 45 ACROSS 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 1383 2271 4033 5189 2918 1156 0 5189 16.18 26.56 47.17 60.69 34.13 13.53 0.00 60.69 26.65 43.77 77.72 100.00 56.23 22.28 0.00 100.00 45 55 65 75 85 2040 1895 1660 1189 693 2450 2366 2347 2438 1103 2769 2819 3023 2189 1241 S/MH: 1.4 SC(ALONG): 1.2; SC(ACROSS): 1.4 FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11052015 REV A (800) 523-3602 • www.simkar.com 30 Altus Classic Center Open Perf 2x4 Technical Specifications Photometric Data Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency Candela Plot Coefficients of Utilization Luminaire Data ACC22OP228T5 UL678964 (2) 28W T5 2625 Advance Centium ICN2S28-N 1.03 60.77 4,155 79.1% CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 94 87 79 72 66 60 56 51 47 43 40 50 94 83 73 64 57 50 45 40 36 33 30 30 94 80 68 58 50 43 38 33 29 26 23 10 94 77 63 53 45 38 33 29 25 21 19 50 88 78 68 61 54 48 43 38 34 31 28 50 30 88 76 65 56 49 42 37 32 29 25 22 10 88 73 61 52 44 37 32 28 24 21 19 50 84 75 66 59 52 46 41 37 33 30 27 30 30 84 73 63 54 47 41 36 32 28 25 22 180 10 84 71 60 51 44 37 32 28 24 21 18 450 60 900 1350 Luminance Summary (Candela/M 2 ) ZONE LUMENS % LAMP % LUMINAIRE ANGLE ALONG 45 ACROSS 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 1095 1803 3232 4155 2351 922 0 4155 20.85 34.35 61.57 79.14 44.79 17.57 0.00 79.14 26.35 43.40 77.80 100.00 56.60 22.20 0.00 100.00 45 55 65 75 85 1631 1519 1334 961 536 1975 1929 1916 1825 850 2252 2341 2457 1768 905 S/MH: 1.4 SC(ALONG): 1.2; SC(ACROSS): 1.4 FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11052015 REV A 120 90 Zonal cavity method Effective floor reflectance = 20% Zonal Lumens and Percentages 150 ACROSS 45 ALONG (800) 523-3602 • www.simkar.com