Installation Instructions Sheet 1 of 4 R1 Ultra Shallow Recessed Concealed Ceiling Installation Instructions Warning : Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically. 1' x 4', 2' x 2', 2' x 4' Exploded View and Part call-out Cut-out Dimensions on Page 2 Ceiling bracing (by others) Sheet rock Metalux DF Series Frame kit Corelite Ultra-shallow recessed fixture (R1 1' x 4' fixture shown) Fixture Size 1x4 2x2 2x4 Assembling the Metalux TM Frame Kit Part # DF-14W-U DF-22W-U DF-24W-U DF Series Frame Kit ? 4ft. section 1x4 assembly shown. 2x4 and 2x2 assemble in same manner. 1ft. section Corner bracket (x4) ????????? ??????????? 1. To assemble Metalux DF series frame kit, firmly insert corner bracket into one side of long sectio n. Ensure corner bracket it facing the inside to the extrusion sections as shown in detail A. Corne r bracket will lock into place when fully positioned. 2. Firmly insert short section to other side of co rner bracket. Repeat until ceiling bracket is full y assembled. Corelite 4675 Holly St Denver, CO 80216 P: 303-393-1522 www.corelite.com ADE080932 REV(A) Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Installation Instructions Sheet 2 of 4 R1 Ultra Shallow Recessed Concealed Ceiling Installation Instructions Warning : Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically. 1' x 4', 2' x 2', 2' x 4' Hole Cut-out dimensions 1' x 4' 2' x 4' 3 +1/8" 12 16 " - 0" 3 +1/8" 24 16 " - 0" 2' x 2' 3 +1/8" 24 16 " - 0" 1 +1/8" 48 4 " - 0" 1 +1/8" 24 4 " - 0" 1 +1/8" 48 4 " - 0" Cut-outs dimensions are exact. In order to maintai n the precision fit of the Metalux DF series frame kit, bracing in ceiling must precisely match above dimensions. Shims may be used to maintain t olerances. Securing Metalux DF Series Frame Kit to Structure i n Ceiling Ceiling Section view Bracing (by others) Sheet rock Screw (by others) Appropriate fasteners (x6) Metalux DF series frame kit 1. After appropriate cut-out is made in sheet rock secure bracket to bracing using appropriate fa joints from opening. Corelite 4675 Holly St Denver, CO 80216 P: 303-393-1522 www.corelite.com ADE080932 REV(A) Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com , insert Metalux DF series frame kit into cut-out a nd steners(by others). Use shims to prevent the brack et Installation Instructions Sheet 3 of 4 R1 Ultra Shallow Recessed Concealed Ceiling Installation Instructions Warning : Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically. 1' x 4', 2' x 2', 2' x 4' Wiring the Fixture Conduit from power source (by others *) Conduit (by others *) Metalux DF series Frame Kit Ground screw Corelite R1 Ultra Shallow Fixture Electrical cover plate 1. Unless top access is available, fixture must be wired prior to installing fixture into Metalux DF series frame kit 2. Remove electrical cover plate from fixture and attach conduit(*supplied by others unless pre-ordered with 6' or 12' whip) to cover plate. 3. Loosen ground screw and secure ground wire to cover plate. Attach appropriate wires ensuring all connections are properly matched. 4. Secure cover plate to fixture. Installing the Pre-wired Fixture Side View Bracing Fixture assembly Sheet rock Acrylic insert 1. After wiring fixture and checking all connectio ns, carefully rotate fixture and lift into into Met alux DF series frame kit. Pre-installed acrylic inser ts will rest on inside edge of Metalux DF series fr ame kit. Corelite 4675 Holly St Denver, CO 80216 P: 303-393-1522 www.corelite.com ADE080932 REV(A) Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Installation Instructions Sheet 4 of 4 R1 Ultra Shallow Recessed Concealed Ceiling Installation Instructions 1' x 4', 2' x 2', 2' x 4' Warning : Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically. Installing Lamps into Fixture Metalux DF series frame kit Lamps Ceiling removed for clarity Lens 1. Gently remove lens from fixture and store in a sa fe place. 2. Slide lamp contacts into sockets at both ends of fixture and rotate lamp to secure in socket. 3. Snap lens back into place around plastic end caps . Slide lamp into socket and rotate Corelite 4675 Holly St Denver, CO 80216 P: 303-393-1522 www.corelite.com ADE080932 REV(A) Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com