6" Down Light Housing Spec Sheet

advertisement
6" Line Voltage New Construction Housing Type IC
PRODUCT SPECIFICATIONS
DLH 6 N 04 Z ICA
6" IC Rated Incandescent
New Construction Housing
Housing Features: For use in insulated ceilings. Integral
thermal protector guards against improper lamping. Single
wall construction. Adjustable socket brackets allow the use
of different lamp types and sizes as well as proper and
consistent lamp positioning.
DLH 6 N 04 Z ICA housing meets restricted air flow
requirement (Per ASTM E-283 Stand).
120V / 150W Max
Ceiling Thickness
Lamp: 120V, 150W Maximum.
Housing adjusts from 5/8"- 1 3/8"
to accommodate various ceiling
thickeness.
Lamp Base: Medium base / E26.
Listings
• UL Listed for Damp
Locations
• UL Listed for Feed Through
• Certified under ASTM-E283
for Air Tight Construction
INSTALLATION
Junction Box: Pre-wired junction box provided with
1/2", 3/4" knockouts for conduit. Maximum (8) No. 12 AWG branch
circuit conductors (4 in, 4 out). Junction box provided with removable
access plates.
Mounting Frame: Stamped galvanized steel material for corrosion
resistance.
• Pre-installed Real-Nails installs inregular lumber or engineered lumber.
• Bar Hangers are adjustable from
5/8" to 25" and can be repositioned 90 degree on plaster frame
Labels:
Dimensions
• U.L. listed for damp locations • U.L. listed for feed through • U.L. listed for direct contact
with insulation.
7 ½"
7 ½"
6 ½"
10 ½"
06.03.16 Rev1
9800 NW 78th Ave, Miami, FL 33016 • PH: 305.364.8099
1
6" Compatible Trims
ǫ
DLT 6 RA W 19
White Trim / Haze Reflector
W
ô
7"
ò
DLT 6 W 30
White Trim / Haze Reflector
W / ...
DLT 6 RA W 38
White Trim / Haze Reflector
W /
ó
DLT 6 RCB W 30
White Trim / W
150W R/PAR30
Ǫ
2 ½"
7"
ó
ó
06.03.16 Rev1
DLT 6 RB W 30
White Trim / W
150W R/PAR30
DLT 6 RG W 30
White Trim / Round Gimbal
75W PAR30
DLT 6 RG W 38
White Trim / Round Gimbal
150W PAR38
9800 NW 78th Ave, Miami, FL 33016 • PH: 305.364.8099
2
Recessed Downlight
WARNING : These products may represent a possible shock or fire hazard if improperly installed or attached in
any way. Products should be installed in accordance with these instructions, current electrical codes and/or
the current National Electric code (NEC).
CAUTION – To reduce risk of fire, electric shock or injury to persons:
1.
2.
3.
4.
Make sure that the electrical power to the fixture is disconnected prior to any installation or retrofit.
This light is suitable for damp locations.
Use with 6” recessed cans (recessed housing) only. Do not attempt to alter for other sizes or purposes.
For best dimming results, use standard incandescent wall dimmers in a branch circuit that is supplied
with 120V AC power. Check dimmer manufacturer ’s specifications to confirm whether minimum loads
apply.
WARNING : Risk of fire or electric shock. Installation requires knowledge of recessed lighting luminaires
electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
Do not use these products in luminaires located where elevated ambient temperatures exist.
WARNING : Risk of fire or electric shock. The electrical rating of this product is 120V AC. The installer must
determine whether power supply is 120V AC at the luminaire before installation.
(120V/277V Ac 50~60Hz is available if 120V/277V is indicated on caution label)
WARNING : Risk of fire or electric shock. Luminaire’s wiring, ballast(s), or other electrical parts may be damaged
when drilling for installation of reflector kit hardware. If drilling is required in any installation, check for enclosed
wiring and components and be careful to protect them from any harm. To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other sharp objects.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTURCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED.
06.03.16 Rev1
9800 NW 78th Ave, Miami, FL 33016 • PH: 305.364.8099
3
Download