warehouse stock catalog

advertisement
WAREHOUSE
STOCK CATALOG
VOLUME 03
A Single Source Solution for HVAC Equipment
TM S JOH NS ON
TMS Johnson is a manufacturers’ representative of HVAC equipment for the contracting
and engineering communities in Minnesota and Western Wisconsin.
TMS Johnson is committed to providing the best products and services
while meeting the most challenging HVAC applications.
With integrity and customer service as the cornerstone of our business,
we look forward to servicing your needs.
Our warehouse has many items in stock and many more products are available
from factory stock in only a few days. We also have many non-stock
products available on quick build programs.
To discuss any of the items featured in this catalog,
or to speak with a sales engineer, contact us at
763-544-5442 or 800-279-4087
We would like to thank you for reviewing our in-stock warehouse catalog!
2
76 3- 544- 5442
w w w .t ms j .c o m
TM S JOH NS ON
Table of Contents
Price Industrial........................................................................................................................................5
Model 520D - Surface Mount Supply Register........................................................................................7
Model 530 - Surface Mount Return Grille................................................................................................7
Model 530-FF - Lay-in Return Filter Grille...............................................................................................8
Model 530D - Return Register.................................................................................................................8
Model SDG-GV-AS - Spiral Duct Grille....................................................................................................8
Model 80 - Eggcrate Return Grilles..........................................................................................................9
Model SCD/ASCD - Lay-in Square Cone Ceiling Diffuser......................................................................10
Model SCDA/ASCDA - Lay-in Square Cone Adjustable Ceiling Diffuser...............................................10
Model PDN - Perforated Diffuser with Neck Deflectors..........................................................................11
Model PDDR - Perforated Diffuser for Return Air Application................................................................11
Model Varitherm VPD-HC - Heating/Cooling Changeover VAV Diffusers...............................................11
Model SPD - Lay-in Architectural Square Plaque Diffuser.....................................................................12
Model RCDE - Round Ceiling Diffuser....................................................................................................12
Model VCR-8E - Butterfly-type Volume Control Damper........................................................................13
Sector Baffle...........................................................................................................................................13
9/16 inch Ceiling Adapter Clip - For Flat 9/16 in. Ceiling T Grid.............................................................13
Model TBDI 4100 - T-Bar Slot Diffuser...................................................................................................14
Model APF - Aluminum Plaster Frame for TBDI 4100............................................................................14
Model SDS100 - Linear Slot Diffusers....................................................................................................15
Universal Plenum - UP / UPL Series.......................................................................................................15
Model LBPH - Floor Register..................................................................................................................16
Model SDV - DDC VAV Terminal Unit.....................................................................................................16
Water Coil - One and Two-Row Hot Water Reheat Coil.........................................................................17
Price Catalog - Terminals........................................................................................................................17
Price Catalog - Terminals........................................................................................................................18
Price Catalog - Terminals........................................................................................................................19
Price Intelligent Controller.......................................................................................................................20
Flexmaster................................................................................................................................................21
Type 1MR6 - Acoustical Flex..................................................................................................................22
Type 9MR4.2 - Insulated.........................................................................................................................22
Square to Round Adapter - Black Coated Interior Square to Round Adapters......................................23
“The Inspector Series” SDSM-Spin Door - High Pressure Access Door for Sheet Metal���������������������23
Model FLD SOG - Take Off with Damper................................................................................................24
Model FLD-BO3 SOG - Take Off with Damper (2 in. Build Out).............................................................24
Greenheck..................................................................................................................................................25
Model G - Centrifugal Direct Drive Roof Exhauster................................................................................26
Model G-VG - Centrifugal Direct Drive Roof Exhauster..........................................................................28
Model GB - Centrifugal Belt Drive Roof Exhauster.................................................................................29
Model WD - Automatic Backdraft Dampers............................................................................................30
Model GPI - Surface Mount Roof Curbs.................................................................................................30
Model SP - Ceiling Exhaust Fans............................................................................................................31
Model CSP - Inline Cabinet Exhaust Fan................................................................................................32
Model RJ - Pitched Roof Cap.................................................................................................................33
Model WC - Hooded Wall Cap...............................................................................................................33
Model RDC - Round Duct Connectors...................................................................................................34
Model 5W and 10W - Speed Controllers................................................................................................34
Model BVE - 157 - Brick Vent.................................................................................................................34
Fusible Links...........................................................................................................................................35
Direct Fired Make-Up Air Parts...............................................................................................................35
Insulated Access Doors..........................................................................................................................35
Paddle/Destratification Fan....................................................................................................................35
Model FD-150 - Static Fire Damper........................................................................................................36
Model FDR-510 - True Round Static Fire Damper..................................................................................36
763-544-5442
w ww .t ms j .c o m
3
TM S JOH NS ON
Table of Contents (Cont.)
4
Model FSD-211 - Fire Smoke Dampers - 120V with Angles...................................................................37
Model OFSD-211 - Out of Wall Fire Smoke Dampers - 120V with Angles.............................................37
Model FSDR-511 - Round Combination Fire Smoke Dampers - 120V with Angles������������������������������38
Model CRD-2 - Ceiling Radiation Fire Damper.......................................................................................38
Model QB-24 - Thermal Insulating Blanket.............................................................................................38
Model ESD-435 - Aluminum Louvers.....................................................................................................39
Model VCD-23 - Opposed Blade Dampers............................................................................................39
Model VCDR-53 - Round Control Damper.............................................................................................40
Belimo Actuators....................................................................................................................................40
WaterFurnace - HEAT PUMPS...............................................................................................................41
Versatec Base - Horizontal 1/2 to 6 Ton.................................................................................................43
Versatec Base - Vertical 1/2 to 6 Ton......................................................................................................44
Armstrong Monitoring - CO/NO2 MONITORS..................................................................................45
Model AMC-1ACO/AMC-1AVC - All-in-one Monitor..............................................................................46
Model MC-VT-221F91AG (CO) - All-in-one Monitor...............................................................................46
Model AMC-1AD1 - Single Zone Multidrop Gas Monitor.......................................................................46
Model AMC-1228-20/AMC-1222 - Gas Sensor Module........................................................................46
Q-Mark - ELECTRIC HEATERS..................................................................................................................47
Model AWH - Architectural Heavy Duty Wall Heaters.............................................................................48
Model MUH - Unit Heater.......................................................................................................................48
Sterling Radiator - HYDRONIC HEATING...........................................................................................49
C-44 Element..........................................................................................................................................50
JVB-S14 16 ga. Slope Top Cover...........................................................................................................50
Modular Panels.......................................................................................................................................50
Terms & Return Policy..........................................................................................................................51
Product Line.............................................................................................................................................52
76 3- 544- 5442
w w w .t ms j .c o m
Price Research Center North (PRCN)
Price’s continued commitment to customer service and superior technology led to the
construction of Price Research Center North (PRCN), the only facility of its kind in North
America. Measuring over 28,500ft2 PRCN is a state of the art laboratory and testing facility
providing the most accurate and reliable test data in the industry.
PRCN demonstrates Price’s leadership in the market and is an excellent resource that
can help you find the best possible solution for any HVAC project. Whether it’s a new
product introduction, specific project mock-up or general tour and product presentation,
you will be given the opportunity to interact with the largest and most experienced
engineering team in the HVAC industry.
Expanded Cooling System • Venturi Testing • AMCA Nozzle Bank
Seven New Test Chambers: Isolation Room, Lab Fume Hood Room
HORD Operating Room, LFD Operating Room, Large Fan Coil Test Chamber,
AHU Test Area, Controls Testing Chamber
Contact TMS Johnson to set up a tour!
www.priceindustries.com
6
P RI CE
Model 520D
Surface Mount Supply Register
Stock Notes
• Steel construction
• Double deflection – 3/4¨ spacing
• Opposed blade damper included
• Blades individually adjustable
• Front blades parallel to short dimension
• Price B12 white powder coat finish
Height
Width
4
6
8
10
12
14
16
18
20
22
24
6
X
210
X
8
180
275
370
X
10
220
340
440
560
X
12
260
410
530
660
790
X
14
300
470
615
750
890
1020
X
16
340
520
700
850
1000
1150
1300
X
18
X
590
780
940
1120
1300
1450
1650
X
20
430
640
860
1040
1250
1440
1660
1770
1990
X
22
X
X
X
1150
1330
X
X
X
X
2300
X
24
510
750
1000
1220
1450
1650
1875
2100
2300
X
2675
30
X
925
1200
1500
1750
2020
2270
2520
2800
X
3300
32
X
X
X
X
X
X
2450
X
X
X
3550
36
X
1075
1425
1770
2050
2400
2725
3000
3300
X
3900
Maximum CFM recommended for NC 30 or less.
Model 530
Surface Mount Return Grille
Stock Notes
• Steel construction
• 45 degree deflection – 3/4¨ spacing
• Fixed louvered face
• Price B12 white powder coat finish
Width
6
8
10
12
14
16
18
20
22
24
30
32
36
48
4
X
145
185
220
250
X
X
X
X
420
X
X
X
X
6
170
230
280
330
395
440
500
550
X
650
800
X
950
X
8
X
300
370
450
510
590
660
730
X
870
1070
1140
1270
X
X
460
550
650
740
830
910
1000
1080
1330
X
1580
X
X
660
770
880
990
1090
1190
1290
1590
X
1880
2450
X
900
1030
1150
1260
X
1500
1840
X
2180
X
X
1160
1310
1440
X
1700
2090
2220
2470
X
X
1450
1600
X
1900
2340
X
2760
3575
X
1770
X
2100
X
X
3050
X
X
2110
X
X
X
X
X
24
X
2480
3050
X
3610
4700
30
X
X
3750
X
4440
5775
36
X
X
X
X
5250
6825
48
X
X
X
X
X
8850
10
12
Height
14
16
18
20
22
Maximum CFM recommended for NC 30 or less.
763-544-5442
w ww .t ms j .c o m
7
P RI CE
Model 530-FF
Lay-in Return Filter Grille
Stock Notes
• Same as Model 530 plus a 1¨ filter frame
• Lay-in ONLY
• Units we stock are hinged
Size
Filter Size
Max CFM at NC 30
24¨ x 24¨
20¨ x 20¨
1750
Maximum CFM recommended for NC 30 or less.
Model 530D
Return Register
Stock Notes
• Steel construction
• 35 degree deflection – 3/4” spacing
• Fixed louvered face
• Price B12 white powder coat finish
• Opposed blade damper
Size
Max CFM at NC 30
6¨ x 6¨
140
8¨ x 8¨
250
10¨ x 10¨
390
12¨ x 12¨
550
14¨ x 14¨
750
16¨ x 16¨
970
18¨ x 18¨
1210
24¨ x 24¨
2050
Maximum CFM recommended for NC 30 or less.
Model SDG-GV-AS
Spiral Duct Grille
Stock Notes
• Double deflection
• With scoop damper
• Countersunk TEK screws provided
• Galvanized finish
Stock Sizes
Min Duct Diameter
Max CFM at NC 30
14¨ x 4¨
8¨
220
24¨ x 4¨
8¨
350
18¨ x 6¨
8¨
410
24¨ x 6¨
14¨
540
Maximum CFM recommended for NC 30 or less.
8
76 3- 544- 5442
w w w .t ms j .c o m
P RI CE
Model 80
80-F Surface Mount Eggcrate Return Grilles
Stock Notes
• Steel border
• 1/2¨ x 1/2¨ x 1/2¨ aluminum core
• Price B12 white powder coat finish
Nominal Duct Size
Max CFM at NC 30
10¨ x 10¨
625
12¨ x 12¨
900
24¨ x 12¨
1750
24¨ x 24¨
3350
48¨ x 24¨
6250
Maximum CFM recommended for NC 30 or less.
80-TB Lay-in Framed Return Grilles
Stock Notes
• Steel border
• 1/2¨ x 1/2¨ x 1/2¨ aluminum core
• Price B12 white powder coat finish
Nominal Duct Size
Module Size
Max CFM at NC 30
22¨ x 4¨
24¨ x 6¨
700
22¨ x 10¨
22¨ x 12¨
1350
22¨ x 22¨
24¨ x 24¨
2800
46¨ x 22¨
48¨ x 24¨
5600
Maximum CFM recommended for NC 30 or less.
80-CORE Lay-in Eggcrate Core Only
Stock Notes
• 1/2¨ x 1/2¨ x 1/2¨ aluminum core
• Price B12 white powder coat finish
Nominal Duct Size
Max CFM at NC 30
24¨ x 6¨
850
24¨ x 12¨
1750
24¨ x 24¨
3350
24¨ x 48¨
6250
Maximum CFM recommended for NC 30 or less.
763-544-5442
w ww .t ms j .c o m
9
P RI CE
Model SCD/ASCD
Lay-in Square Cone Ceiling Diffuser
Stock Notes
• SCD - Steel Construction
• ASCD - Aluminum Construction
• 360 degree fixed air pattern
• Price B12 white powder coat finish
Available Accessories
• SPF mounting frame for surface
mount applications
• VCR-8E dampers
• 4th cone
• Corner clips
Neck Size
Face Size
Max CFM at NC 30
6¨
12¨ x 12¨
245
6¨
24¨ x 24¨
250
8¨
12¨ x 12¨
360
8¨
24¨ x 24¨
400
12¨ x 12¨
10¨
24¨ x 24¨
580
24¨ x 12¨
12¨
24¨ x 24¨
775
24¨ x 24¨
14¨
24¨ x 24¨
1000
24¨ x 48¨
Surface Mount Frames – SPF
* Rough in size 1/4¨ larger than nominal dimensions
Maximum CFM recommended for NC 30 or less.
Model SCDA/ASCDA
Lay-in Square Cone Adjustable Ceiling Diffuser
Stock Notes
• SCDA - Steel Construction
• ASCDA - Aluminum Construction
• 360 degree adjustable air pattern
• Price B12 white powder coat finish
Available Accessories
• SPF mounting frame for surface mount applications
• VCR-8E dampers
Neck Size
Face Size
CFM Vertical Throw
6¨
12¨ x 12¨
180
CFM Horizontal Throw
210
8¨
12¨ x 12¨
225
300
6¨
24¨ x 24¨
180
220
8¨
24¨ x 24¨
275
350
10¨
24¨ x 24¨
400
510
12¨
24¨ x 24¨
550
700
14¨
24¨ x 24¨
700
925
Maximum CFM recommended for NC 30 or less.
10
76 3- 544- 5442
w w w .t ms j .c o m
P RI CE
Model PDN
Perforated Diffuser with Neck Deflectors
Stock Notes
• Steel construction
• B12 white
• Deflectors removable for exhaust use
• Adjustable deflectors on neck
Available Accessories
• SPF mounting frame
Duct Size
Module Size
Max CFM at NC 30
6¨
24¨ x 24¨
135
8¨
24¨ x 24¨
200
10¨
24¨ x 24¨
300
12¨
24¨ x 24¨
390
14¨
24¨ x 24¨
500
Performance shown is for 4-way throw.
Maximum CFM recommended for NC 30 or less.
Model PDDR
Perforated Diffuser for Return Air Application
Stock Notes
• Steel construction
• B12 white
Nominal Duct Size
Module Size
Max CFM at NC 30
6¨
24¨ x 24¨
440
8¨
24¨ x 24¨
660
10¨
24¨ x 24¨
930
12¨
24¨ x 24¨
1200
14¨
24¨ x 24¨
1500
16¨
24¨ x 24¨
1825
22¨ x 10¨
24¨ x 12¨
2075
22¨ x 22¨
24¨ x 24¨
4225
Maximum CFM recommended for NC 30 or less.
Varitherm VPD-HC
Heating/Cooling Changeover VAV Diffusers
Stock Notes:
• Minimum airflow adjustment
• Individual heating and cooling set points
• Hinged face for room side adjustment
• No thermostat or wiring needed
763-544-5442
Size
Max CFM at NC 30
6¨
200
8¨
300
10¨
400
12¨
500
Maximum CFM recommended
for NC 30 or less.
w ww .t ms j .c o m
11
P RI CE
Model SPD
Lay-in Architectural Square Plaque Diffuser
Stock Notes
• Steel construction
• 360 degree horizontal air pattern
• Price B12 white powder coat finish
Available Accessories
• SPF mounting frame for surface mount applications
• VCR-8E dampers
Neck Size
Face Size
Max CFM at NC 30
6¨
12¨ x 12¨
210
6¨
24¨ x 24¨
245
8¨
12¨ x 12¨
310
8¨
24¨ x 24¨
380
10¨
24¨ x 24¨
550
12¨
24¨ x 24¨
725
14¨
24¨ x 24¨
925
Maximum CFM recommended for NC 30 or less.
Model RCDE
Round Ceiling Diffuser
Stock Notes
• Steel construction
• 360 degree horizontal air pattern
• Two horizontal discharge patterns
• Price B12 white powder coat finish
Available Accessories
• VCR-8E damper
Nominal Duct Size
Max CFM at NC 30
6¨
200
8¨
280
10¨
490
12¨
705
14¨
800
Maximum CFM recommended for NC 30 or less.
12
76 3- 544- 5442
w w w .t ms j .c o m
P RI CE
Model VCR-8E
Damper Blades in fully Open Position
Butterfly-type Volume Control Damper
B
Damper mounts directly to any round diffuser
neck inlet that is sized nom. - 1/8 in.
Damper end plate c/w integral spring tabs
for press-on fit to neck inlet of diffuser.
Top View of Damper
A
Dimensions = inch/mm
NOMINAL SIZES
4¨
5¨
6¨
7¨
8¨
10¨
12¨
14¨
15¨
A
3 7/8¨ (98)
4 7/8¨ (124)
5 7/8¨ (150)
6 7/8¨ (175)
7 7/8¨ (200)
9 7/8¨ (250)
11 7/8¨ (302)
13 7/8¨ (352)
14 7/8¨ (378)
B
1 3/4¨ (44)
2 1/4¨ (57)
2 3/4¨ (70)
3 1/4¨ (82)
3 3/4¨ (95)
4 3/4¨ (120)
5 3/4¨ (146)
6 3/4¨ (171)
7 1/4¨ (184)
Sector Baffle
The sectorizing baffle is a field installed
accessory used to blank-off a portion of the
inlet to create a special irregular air pattern.
Baffles are available in multiples of 45˚ for
Models SPD, SCD, RCD, RCDE and
RCDA diffusers.
9/16” Ceiling Adapter Clip
For Flat 9/16 in. Ceiling T Grid
Increases corner size to 15/16 in. flat ceiling T
equivalent. Use when frame style 916, 916P
is not available. Four clips required per diffuser.
Supplied in boxes of 100.
1 1/2¨
9/16¨
763-544-5442
w ww .t ms j .c o m
916 Clip
13
P RI CE
Model TBDI 4100
T-Bar Slot Diffuser
Stock Notes
• Adjustable pattern control
• Steel construction
• Insulated plenum fiber free foam
• Black exposed surfaces and white center t-bar
• Diffusers are stocked with oval inlet, equivalent
round is shown in table
Available Accessories
• Mounting frame for surface mount applications
Model
Insulated
Length
# of Slots
Slot Width
H
D
W
Max CFM at NC 30
4100
Y
2 ft.
2
1¨
10¨
6¨
4¨
150
4100
Y
2 ft.
2
1¨
10¨
8¨
4¨
170
4100
Y
4 ft.
2
1¨
12¨
8¨
4¨
275
4100
Y
4 ft.
2
1¨
12¨
10¨
4¨
320
4100
Y
4 ft.
3
1¨
12¨
12¨
6¨
575
Maximum CFM recommended for NC 30 or less.
Model APF
Aluminum Plaster Frame for TBDI 4100
Stock Notes
• Used to install slot diffusers in sheetrock or plaster ceilings
• Extruded aluminum construction
• White finish
• Rough in dimension:
2 Slot - 48 7/16¨ x 4 7/16¨
2 Slot - 24 7/16¨ x 4 7/16¨
3 Slot - 48 7/16¨ x 6 7/16¨
14
76 3- 544- 5442
w w w .t ms j .c o m
P RI CE
Model SDS100
Linear Slot Diffusers
Stock Notes
• T-bar lay-in or surface mount concealed frames available
• 180˚ adjustable pattern control
• Solid extruded aluminum border and frame construction
• 1¨ slot spacing
Length (zz)
Length (ww)
Width
Size
Max CFM at NC 30
23.75
24.75
4.25
2˙ x 2˙ slot
210
23.75
24.75
7.25
2˙ x 4˙ slot
385
47.75
48.75
4.25
4˙ x 2˙ slot
385
47.75
48.75
4.25
4˙ x 4˙ slot
650
Maximum CFM recommended for NC 30 or less.
Universal Plenum
UP / UPL Series
Stock Notes
• Zinc coated steel construction with 1/4¨ fiber-free insulation
• Plenums have oval inlet with overall height of 9¨
• 24¨ and 48¨ plenums are in stock for the SDS100 diffuser
UPL Universal Plenum Low Profile
tion
Sec
A-A
2 1/2¨
th -
9”
L=
ng
. Le
¨
1/4
m
No
1¨
Oval Duct
Internal
Insulation
(optional)
2 1/2¨
(W-1/2)
W
Section A-A
763-544-5442
(1/4 Typ.)
w ww .t ms j .c o m
15
P RI CE
Model LBPH
Floor Register
Stock Notes
• 25 C pencil proof core
• # 1000 border
• B¨ spring clip mounting
• VCS3 damper
• #66 brushed clear coat aluminum finish
Available Sizes
• 12 x 6
• 12 x 8
• 16 x 6
• 16 x 8
• 20 x 6
• 20 x 8
• 24 x 6
• 24 x 8
Model SDV
DDC VAV Terminal Unit
Stock Notes
• Zinc coated steel housing, sealed
and gasketed for leak resistance
• Controls and actuator by others
• Sheet metal enclosure included
• Price SP200 velocity pressure sensor
• 3/4¨ Price fiber free foam lining
• Model PKIT with CP101 Pneumatic Controller
accommodates direct and reverse acting
thermostats and normally open or normally
closed position
Unit Size
CFM Min.
Max CFM at NC 30
Inlet A
Outlet B
Outlet C
Length L
6
66
450
6¨
12¨
8¨
20 1/8¨
8
132
800
8¨
12¨
10¨
20 1/8¨
10
221
1350
10¨
14¨
12 1/2¨
20 1/8¨
12
304
2100
12¨
16¨
15¨
20 1/8¨
14
439
3000
14¨
20¨
17 1/2¨
23 5/8¨
16
568
4000
16¨
24¨
18¨
23 5/8¨
24¨ x 16¨
1187
8000
24¨ x 16¨
38¨
18¨
19¨
Optional NEMA Controls Enclosure
18 1/2” (470)
4 3/4” (121)
Optional Bottom Access Door (AD)
16
76 3- 544- 5442
w w w .t ms j .c o m
P RI CE
Water Coil
One and Two-Row Hot Water Reheat Coil
Stock Notes
• Used on SPV and SDV terminal units
• With access door top and bottom
VAV Unit Size
B
C
L
6
12¨
8¨
9¨
Coil Connection
7/8¨ OD
8
12¨
10¨
9¨
7/8¨ OD
10
14¨
12.5¨
9¨
7/8¨ OD
12
16¨
15¨
9¨
7/8¨ OD
14
20¨
17.5¨
9¨
7/8¨ OD
16
24¨
18¨
9¨
7/8¨ OD
24¨ x 16¨
38¨
18¨
9¨
7/8¨ OD
6¨ and 8¨ 1-row coils have 1/2¨ OD coil connection.
Single Duct Terminal Units - SPV, SDV Series
Single Duct – Controller Type
1 and 2 Row Hot Water Coil Data – IP Units
Tables are based on high temperature water (180 °F)
Inlet Size 4, 5, 6 (Standard Coils)
Air Flow Rate, cfm
Coil
HD
Rows
gpmLoss125150175200225250300350400
1 Row
0.50.155.35.86.26.56.87.17.68.08.4
multi-1 0.455.96.67.17.68.08.49.19.710.3
circuit2 1.356.47.17.78.38.89.310.21111.6
3 2.596.57.38.08.69.29.710.611.512.2
Through the Coil, ∆Ps 0.020.020.030.040.050.060.090.110.14
2 Row 1 0.2 9.8 10.911.812.713.414.115.316.317.2
multi- 2 0.6510.712.013.314.415.416.317.919.320.6
circuit 4 2.1511.312.814.215.416.617.719.721.423.0
6 4.3811.513.114.515.817.118.220.422.223.9
Through the Coil, ∆Ps 0.040.050.070.090.110.130.180.24 0.3
Size 4
Inlet Size 7, 8 (Standard Coils)
Size 5
Air Flow Rate, cfm
Coil
HD
Rows
gpmLoss200250300350400500600700800
1 Row
0.50.27.48.18.79.29.610.310.911.311.7
single 1 0.6 8.6 9.6 10.411.211.812.913.814.515.2
circuit 2 1.77 9.3 10.611.612.513.414.816.017.017.9
3 3.37 9.6 10.912.113.114.015.616.918.119.1
Through the Coil, ∆Ps 0.020.040.050.070.090.130.180.24 0.3
2 Row 1 0.2514.015.717.218.419.421.222.623.724.7
multi- 2 0.7915.818.120.021.723.325.928.029.831.4
circuit 4 2.5616.919.521.924.025.829.132.034.436.5
6 5.1617.320.122.624.826.930.533.636.338.7
Through the Coil, ∆Ps 0.050.080.110.140.180.270.38 0.5 0.63
Size 7
763-544-5442
w ww .t ms j .c o m
17
P RI CE
Inlet Size 9, 10 (Standard Coils)
Air Flow Rate, cfm
Coil
HD
Rows
gpm
Loss
300
400
500
600
700
800
900
1000
1100
1 Row 1 0.1911.412.914.115.015.816.517.117.618.1
multi- 2 0.6 13.015.016.618.019.220.221.222.022.7
circuit 4 2.0214.016.418.420.121.622.924.125.226.2
6 4.1514.417.019.121.022.624.125.426.627.7
Through the Coil, ∆Ps 0.030.040.070.090.120.150.190.230.27
2 Row 1 0.3219.522.424.626.327.829.030.030.931.7
multi- 2 1.0 22.726.730.032.735.137.138.940.542.0
circuit 4 3.1624.729.633.737.340.443.245.748.050.0
6 6.2725.430.735.239.142.645.748.651.253.5
Through the Coil, ∆Ps 0.050.090.140.190.250.32 0.4 0.480.57
Size 9
Inlet Size 12 (Standard Coils)
Air Flow Rate, cfm
Coil
HD
Rows
gpm
Loss
400
500
600
700
800
1000
1200
1400
1600
1 Row 1 0.2314.816.217.418.419.220.621.722.623.4
multi- 2 0.7217.119.120.822.323.625.827.629.130.4
circuit 4 2.3618.721.123.225.126.729.632.034.135.9
6 4.7719.321.924.226.228.031.233.936.238.3
Through the Coil, ∆Ps 0.020.040.050.070.090.130.180.24 0.3
2 Row 1 0.4124.727.329.431.132.534.836.537.939.1
multi- 2 1.2329.533.436.639.541.9 46 49.452.154.5
circuit 4 3.8332.637.541.745.548.954.759.663.867.4
6 7.5133.839.143.848.051.758.464.068.973.2
Through the Coil, ∆Ps 0.050.080.110.140.180.270.38 0.5 0.63
Inlet Size 14 (Standard Coils)
Air Flow Rate, cfm
Coil
HD
RowsgpmLoss 600 800 1000120014001600180020002200
1 Row 1 0.2920.322.624.425.726.927.828.629.329.9
multi- 2 0.8924.427.930.632.934.936.638.039.340.5
circuit 4 2.8527.131.535.238.341.043.445.547.449.1
6 5.6828.233.037.140.643.646.348.750.953.0
Through the Coil, ∆Ps 0.030.040.070.090.120.150.190.230.27
2 Row1.5 0.4236.841.745.448.350.652.654.355.756.9
multi- 3 1.3543.951.357.362.366.570.173.276.078.5
circuit 6 4.4448.557.965.872.678.583.788.492.696.4
9 9.0 50.360.569.276.883.589.594.999.8104.3
Through the Coil, ∆Ps 0.050.090.140.190.250.32 0.4 0.480.57
Inlet Size 16 (Standard Coils)
Air Flow Rate, cfm
18
CoilHD
Rows gpm Loss
1 Row 1
0.32
multi- 2
0.98
circuit 4
3.09
6
6.14
Through the Coil, ∆Ps
800 10001200140016001800200022002400
24.226.127.728.929.930.831.632.232.8
29.933.035.637.839.641.342.744.045.2
33.938.041.544.547.249.651.853.755.5
35.540.144.047.450.553.255.758.060.1
0.030.050.070.090.110.140.160.190.23
2 Row 1.5 0.47
multi- 3
1.47
circuit 6
4.77
9
9.62
Through the Coil, ∆Ps
44.048.051.253.855.957.759.260.661.7 62.7 63.7
54.360.966.371.075.078.581.684.386.8 89.0 91.1
61.369.977.484.089.895.099.8104.0108.0111.6115.0
64.073.682.089.496.1102.1107.7112.7117.4121.7125.8
0.07 0.1 0.140.180.230.280.340.410.48 0.55 0.63
76 3- 544- 5442
w w w .t ms j .c o m
2600 2800
33.3 33.8
46.3 47.2
57.2 58.7
62.1 63.9
0.26 0.3
P RI CE
Inlet Size 24x16 (Standard Coils)
Air Flow Rate, cfm
Coil
HD
Rows gpm Loss 1200 15002000250030003500400045005000
1 Row 1
0.43 32.434.537.138.840.241.242.042.743.3
multi- 2
1.28 42.446.451.555.358.460.862.964.666.1
circuit 4
3.96 49.855.663.369.474.478.782.385.588.4
6
7.75 52.959.468.475.781.8 87 91.595.699.2
Through the Coil, ∆Ps
0.030.040.070.110.15 0.2 0.250.310.37
5500 6000
43.8 44.2
67.5 68.6
90.9 93.2
102.4105.4
0.44 0.52
2 Row 1.5 0.61
multi-
3
1.88
circuit
6
5.93
9
11.76
Through the Coil, ∆Ps
79.6 80.3
127.2 129.4
176.3 181.1
201.0 207.4
0.93 1.09
57.962.367.370.773.275.176.677.878.8
76.0 84.4 95.0 102.9109.1114.1118.2121.7124.6
89.2 101.3117.7130.7141.5150.5158.3165.0171.0
94.6 108.3127.5143.1156.3167.6177.5186.2194.0
0.060.090.150.220.310.410.520.650.78
Correction Factors – Hot Water Coils
Entering Water Temperature, °F
120 130140150160170180190200210
220
Entering
50 0.54 0.620.710.790.870.961.041.121.211.29
1.38
Air Temp °F55 0.50 0.590.670.750.830.921.001.081.171.25
1.34
60 0.47 0.550.630.710.790.880.961.041.131.21
1.30
65 0.43 0.510.590.670.750.840.921.001.091.17
1.26
Performance Notes:
1. Tabulated values are in MBH (thousands of Btu per hour).
2. Tables are based on a temperature difference of 125 °F
(180 °F entering water temperature and 55 °F entering
air temperature). For other temperature differences,
multiply MBH values by factors as listed above.
3.Minimum air and water flow values are based on
ASHRAE recommendations for coil selections. For
selections below these tabulated air or water values,
please consult your local Price representative.
4. Do not select coils for a leaving air temperature above
120 °F.
5. HD (Head) loss is in feet of water.
6. Ps, is the pressure drop in in. of water across the coil.
7. Air temperature rise = ATR, ATR ( °F) = 927 x MBH/cfm.
8. Water temperature drop = WTD, WTD (°F) = 2.04 x MBH/
gpm.
9. Values in tables are listed for 0 ft of altitude and no glycol
in the system.
763-544-5442
10.For information outside the ranges used in the table, consult
the current Price software or your Price representative for
accurate coil information.
11.Heating coils used in this unit have performance rated
and certified in accordance with the current edition of
AHRI Standard 410.
12.Connections: Standard Terminal Sizes 4, 5, 6, 7, 8
and high capacity size 9-14 – 1/2 in. OD male solder
All others – 7/8 in. OD male solder.
w ww .t ms j .c o m
19
Price Intelligent
Controller (PIC)
An advanced and configurable
proportional integral (PI) controller
allows for exceptional user comfort
and energy efficiency. Installation
of the controller and thermostat is
simple and error proof with RJ-45
(network type) connections
to the thermostat.
The PIC is available with several thermostat
options allowing the designer to match the
specific needs of the customer. All Price
thermostats, except the wireless model, have
an RJ-12 service port allowing setup and
configuration access without having
to access the plenum.
PIC Features
• Fast and error proof RJ-45 thermostat connections
• Integrated actuator
• 24 VAC binary outputs field selectable between
hot and common switching
• Analog (0-10 VDC) outputs for heating, cooling,
fan and auxiliary
• Field installable expansion modules for BACnet MS/TP
and VAV flow sensing
• Pluggable terminal blocks for easy field wiring
• Diagnostic LED’s showing status of each output
including damper open / close
Item
Description
PIC
Price Intelligent Controller (DDC) for pressure independent terminal unit control with a variety of heating interface
including 24 VAC binary (staged electric reheat), PWM, 0-10 VDC. Requires 24 VAC power, 6 VA (not including output loading).
PICLEDSTAT
LCD display thermostat. Balancing and modifications to the controller setup can be accomplished through the LCD screen.
Includes 35 feet of cable with RJ-45 connections.
PICDIALSTAT
Dial thermostat. Includes 35 feet of cable with RJ-45 connections.
PICTRAN
Transformer, 120/240/277/480 Volt primary, 24 Volt secondary, 50 VA
PICPRB
Inlet duct thermister for Heating/Cooling changeover.
PICBACnet
BACnet MS/TP module allows for network communication of PIC controller.
Price Intelligent Controller
For HVAC Zone Control
www.priceindustries.com
20
21
F L EX M A S TER US A
Type 1MR6 - Acoustical Flex
Type 1 - Core is an Acoustical Polyurethane (PE)
M - Metallized Vapor Barrier
R - R6
Metal Helix
The core material is an acoustical transparent PE fabric
supported by helically wound galvanized steel. The fabric
shall be mechanically fastened to the steel helix without
the use of adhesive. The core maintains its free area
and a center line radius of 1.0 or better.
Overlapping
Fabric Folds
Filler
The internal working pressure rating is at least the following
with a bursting pressure of at least 2 _ times the working pressure.
Positive:
10 in. W.G. thru 20¨ diameter
Negative:
5 in. W.G. thru 16¨ diameter
The duct is rated for a velocity of at least 5500ft/minute and is suitable for operating
temperatures of at least 250°F. The insertion loss (dB) of a 6ft. length of duct when
tested in accordance with ASTM E 477 at a velocity of 1000ft/minute is:
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8 in. diameter
5
10
22
34
22
17
12 in. diameter
6
27
22
28
18
11
Factory insulate of the flexible duct is with flexible fiberglass insulation. The R value is at least 6.0 at a mean temperature
of 75°F. Cover the insulation with a reinforced aluminum pigmented vapor barrier jacket having a permeance of not greater
than 0.05 perms when tested in accordance with ASTM E 96, procedure A. The ductwork is UL 181 Listed, Class 1 Air
Duct and compliant with NFPA 90A and 90B. The basis of the design is Flexmaster Type 1MR6.
Type 9MR4.2 - Insulated
Flexmaster’s Type 9M is manufactured to meet the highest quality
standards in strength, permeability and fire resistance required in a
flexible air duct. This insulated, ETL Rated to UL-171 Class I AIR DUCT
Standards is fabricated with a double lamination of tough polyester
which encapsulates a steel wire helix..
Construction Features
Liner – Double lamination of tough polyester which encapsulates a steel wire helix
Encapsulated Helix – Corrosion Resistant Galvanized Steel Helix
Vapor Barrier – Fire retardant reinforced aluminum material. Excellent strength at low temperatures. Will not age harden.
Insulation – Fiberglass insulation blanket, factory wrapped
Technical Data
Standard Length (feet) – 25 ft.
Inside Diameter (inches) – 6¨ - 12¨
Vapor Barrier Permeance – .05 perm A.S.T.M. E96, Procedure A
ETL Listed – Approved to UL 181, Class 1 Air Duct
Standard Codes – NFPA 90A and 90B, BOCA,
SBBC, HUD/FHA, MIN Property Std.
Rated Velocity – 5,500 FPM
22
Working Pressure (W.G.) – 6¨ w.g. positive; 1/2¨ w.g. negative
Minimum Burst Pressure – 2 1/2 times working pressure
Operating Temperature Range – -20˚F to 200˚F Intermittent;
-20˚F to 180˚F Continuous
Flame Spread – Less than 25
Smoke Developed – Less than 50
Thermal Conductance – Available: R-4.2
76 3- 544- 5442
w w w .t ms j .c o m
F L EX M A S TER US A
Square to Round Adapter
Black Coated Interior Square to Round Adapters
Stock Notes
• Black interior
• 26 ga. primed G-90 galvanized steel
• 1/8¨ tolerance
• Closed corner
• F3SC – 3¨ depth, square: closed corner
Sizes
10¨ x 10¨
6¨ – 10¨ Collar
12¨ x 12¨
6¨ – 12¨ Collar
24¨ x 12¨
6¨ – 12¨ Collar
24¨ x 24¨
6¨ – 16¨ Collar
“The Inspector Series” SDSM-Spin Door
High Pressure Access Door for Sheet Metal
Stock Notes
• Low leakage
• Quick installation
• Safe Entry and Exit
• Insulation option – R4.2
Nominal Door Size AMin. Hole Cut Size*
8¨
7 3/16¨
10¨
9 3/16¨
12¨
11 3/16¨
18¨
17 3/16¨
THE INSPECTOR SERIES – SPIN DOOR’s unique round construction provides for a quick installation as its outer
frame is spun into the sheet metal duct and then the self sealing inner door is put into place and locked by turning
the preinstalled latches. The outer SPIN DOOR frame is made of 22-gauge galvanized steel, rolled and double hemmed.
The inner door is made of 24-gauge galvanized steel, rolled and triple hemmed.
763-544-5442
w ww .t ms j .c o m
23
F L EX
TM
MSA S
JOH
TERNS
US
ON
A
Model FLD SOG
Take Off with Damper
Stock Notes
• 26 ga., G-90 galvanized steel pre-punched
• 1 1/2¨ wide integral flange
• Adhesive neoprene gasket with peel back tape
Available Sizes
6¨
8¨
10¨
12¨
Model FLD-BO3 SOG
Take Off with Damper (2¨ Build Out)
Stock Notes
• 26 ga., G-90 galvanized steel pre-punched
• 1 1/2¨ wide integral flange
• Adhesive neoprene gasket with peel back tape
Available Sizes
6¨
8¨
10¨
12¨
24
76 3- 544- 5442
w w w .t ms j .c o m
25
G REENH ECK
Model G
Centrifugal Direct Drive Roof Exhauster
Model G Centrifugal Exhaust fans are direct driven
fans designed for roof-mounted applications exhausting
relatively clean air. They feature a spun aluminum
housing and a non-overloading, backward inclined
aluminum wheel. Motors are located out of the air
stream with positive cooling by ambient air. Model G
fans are UL listed and licensed to bear the AMCA
Certified Ratings Seals for air and sound performance.
B
Stock Notes
• Units are stocked with 115/60/1 motors
• Disconnect switch included
• Rigid wire birdscreen included
Available Accessories
• Prefab roof curbs
• Speed controls
• Backdraft dampers (Model WD-100)
• All G fans use a 5W speed controller
C
1.75
A
Model
A
B
C
Roof Opening
G-75
17¨
19 3/8¨
12 1/8¨
10 1/2¨
8¨ x 8¨
G-85 to G-95
17¨
21 3/4¨
14 5/8¨
12 1/2¨
10¨ x 10¨
HP
RPM
Sones @
0 in.
Max BHP
E
1/80
1050
3.3
Model
G-75
3-Speed
G-85
3-Speed
G-95
3-Speed
26
Damper Size
Pressure in inches WG
0
.125
.011
296
200
.25
G
1/50
1300
4.4
.021
367
294
195
D
1/25
1550
6.1
.035
438
377
310
E
1/40
1050
3.6
.019
399
307
179
.375
.5
.625
169
214
G
1/30
1300
5.4
.036
494
421
340
233
D
1/20
1550
7.5
.062
588
529
464
393
308
E
1/30
1050
4.9
.037
717
569
389
G
1/12
1300
7.4
.071
888
780
640
493
184
D
1/8
1550
9.6
.120
1059
969
863
745
623
76 3- 544- 5442
474
w w w .t ms j .c o m
.75
G REENH ECK
Model G-VG
Centrifugal Direct Drive Roof Exhauster
Model G Centrifugal Exhaust fans are direct driven
fans designed for roof-mounted applications exhausting
relatively clean air. They feature a spun aluminum
housing and a non-overloading, backward inclined
aluminum wheel. Motors are located out of the air
stream with positive cooling by ambient air. Model G
fans are UL listed and licensed to bear the AMCA
Certified Ratings Seals for air and sound performance.
B
Stock Notes
• Units are stocked with Vari-Green motors
• Disconnect switch included
• Rigid wire birdscreen included
Available Accessories
• Prefab roof curbs
• Backdraft dampers (Model WD-100)
C
4
1.75
A
28
Model
A
B
C
Roof Opening
G-95-VG
17¨
21.75¨
14.63¨
12.5¨ x 12.5¨
10¨ x 10¨
G-133-VG
19¨
28.38¨
23.75¨
14.5¨ x 14.5¨
12¨ x 12¨
G-143-VG
22¨
28.38¨
23.75¨
18.5¨ x 18.5¨
16¨ x 16¨
Model
HP
RPM
Sones @
0 in.
Max BHP
G-95-VG
1/6
1725
11.3
G-133-VG
3/4
1725
G-143-VG
1
1725
Damper Size
Pressure in inches WG
0
0.125
0.250
0.375
0.500
0.625
0.750
0.15
1179
1095
1000
890
785
670
525
17
0.53
2445
2380
2325
2275
2200
2150
2060
1900
25
0.99
3200
3125
3050
2975
2885
2795
2720
2525
76 3- 544- 5442
w w w .t ms j .c o m
1.000
G REENH ECK
Model GB
Centrifugal Belt Drive Roof Exhauster
Model GB Centrifugal Exhaust fans are belt driven fans
designed for roof mounted applications exhausting relatively
clean air. They feature a spun aluminum housing and
a non-overloading, backward inclined aluminum wheel.
Motors are located out of the air stream with positive
cooling by ambient air. Model GB fans are UL listed and
licensed to bear the AMCA Certified Ratings Seals
for air and sound performance.
B
Stock Notes
• Units are stocked with 115/60/1 motors
• Disconnect switch included
• Rigid wire birdscreen included
Available Accessories
• Prefab roof curbs
• Backdraft dampers (Model WD-100)
C
1.75
A
Model
A
B
C
Roof Opening
GB-081, GB-091
19¨
24 3/8¨
23 3/4¨
14 1/2¨
Damper Size
12¨ x 12¨
GB-101, G-121
19¨
24 3/8¨
23 3/4¨
14 1/2¨
12¨ x 12¨
GB-131
19¨
28 3/8¨
23 3/4¨
14 1/2¨
12¨ x 12¨
GB-161
22¨
28 3/8¨
23 3/4¨
18 1/2¨
16¨ x 16¨
Model
HP
RPM
Sones @
0 in.
Max BHP
GB-081
1/4
1710
12.5
0.25
GB-091
1/4
GB-101-4X-R4
GB-121-4X
GB-131-5X
GB-161-5X
1/4
1/4
1/2
1/2
Pressure in inches WG
0
.125
.25
.375
.5
.625
.75
1
856
821
785
745
710
669
630
511
934
785
1710
13.2
0.25
1296
1238
1180
1122
1062
999
1324
8.4
0.11
1122
1050
982
911
819
686
1688
11.9
0.28
1431
1373
1318
1264
1216
1153
1083
891
980
6.5
0.07
1190
1093
984
848
616
1395
12.5
0.25
1692
1625
1557
1484
1404
1315
1214
907
942
7.5
0.08
1337
1234
1115
952
1435
1305
2428
2197
1315
13.2
0.26
1866
1794
1718
1637
1545
852
10.4
0.23
2518
2320
2118
1884
1557
1100
15.3
0.53
3249
3094
2943
2786
2614
763-544-5442
w ww .t ms j .c o m
29
G REENH ECK
Model WD
Automatic Backdraft Dampers
Model WD dampers feature a frame constructed
of heavy gauge galvanized steel with pre-punched
mounting holes for ease of installation. Blades are
fabricated from aluminum with felt seals on the closing
edge. Each blade pivots on nylon brushings to assure
quiet and smooth operation.
Stock Notes
• WD-100 dampers are designed for use with roof
mounted Greenheck exhaust fans
• WD-330 dampers are designed for vertical duct mount
• Motor pack (115, 230 and 460 volt)
can be ordered from the factory
• Dampers are for relatively clean air applications ONLY
Stock Sizes for both models WD-100 and WD-330
• 8¨ x 8¨
• 16¨ x 16¨
• 10¨ x 10¨
• 18¨ x 18¨
• 12¨ x 12¨
• 20¨ x 20¨
• 14¨ x 14¨
• 24¨ x 24¨
Model GPI
Surface Mount Roof Curbs
Stock Notes
• Flush wood nailers
• Unitized construction
• 18 gauge galvanized steel construction
• 1.5¨ thick, 3 lb. density fiberglass insulation
• 2¨ flashing strip
• Inside dimensions are 3¨ less than outside dimensions
• Hinge kits
• Curb adapters 17/19 and 19/22
30
Curb Size
Dimensions OD x H
17
15.5¨ x 15.5¨ x 18¨
G-75 to G-95; G-95-VG
Stock Fan Sizes
19
17.5¨ x 17.5¨ x 18¨
G-133-VG
GB-081 to GB-131
22
20.5¨ x 20.5¨ x 18¨
G-143-VG
GB-161
26
24.5¨ x 24.5¨ x 18¨
30
28.5¨ x 28.5¨ x 18¨
34
32.5¨ x 32.5¨ x 18¨
40
38.5¨ x 38.5¨ x 18¨
46
44.5¨ x 44.5¨ x 18¨
76 3- 544- 5442
w w w .t ms j .c o m
G REENH ECK
Model SP
B
SP-A 700
SP-A 900 through 1550
Ceiling Exhaust Fans
Model SP ceiling exhaust fans are designed for
applications where low sound levels are critical. They
are ideal selections for offices, conference rooms and
restrooms. Their low sound levels are achieved through
quiet running forward curved wheels. Models SP-A190
and higher also feature a ½” of acoustical insulation in
housing for an even quieter performance. All model SP
fans are UL listed and licensed to bear the AMCA
Certified Ratings Seals for air and sound performance.
Stock Notes
• Units are stocked with 115/60/1 motors
• Plug-in disconnect switch included
• Integral backdraft damper
• All SP fans require 5W Speed Controller
Available Accessories
• Speed controls
• Wall and discharge accessories
Model
RPM
AMPS
B
A
SP-A 110 through 510
SP-A 710 and 780
square outlet
E
Watts
HVI
SP-B70
675
0.53
45
1.4
SP-B90
700
0.65
50
2.0
SP-B110
950
1.14
80
1.5
SP-A110
950
.58
49
1.3
SP-B150
1050
1.70
129
2.5
SP-B200
1100
2.20
173
4.0
SP-A190
1400
1.3
113
2.0
SP-A250
1000
.77
83
2.0
SP-A290
1050
0.72
81
2.5
SP-A390
1000
1.74
121
3.0
SP-A410
1000
1.74
121
3.0
SP-A510
1070
3.30
224
4.5
SP-A710
1080
4.40
285
6.0
SP-A900
950
4.00
285
4.5
763-544-5442
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
0
77
1.7
102
1.9
133
2.0
119
1.3
160
3.0
197
4.4
216
3.2
272
2.9
315
3.2
443
4.1
443
4.1
557
6.0
752
7.4
955
5.2
C
D
B
C
D
B
A
D C
E
SP-B
B
A
E
SP-A 110 through 510
SP-A 710 and 780
round outlet
A
E
C
D
315/16 in.
A
E
SP-A 50-90
C
D
Model
A
B
C
SP-B70
SP-B90, 110, 150, 200
SP-A190, 110
SP-A290, 250
SP-A390, 410, 510
SP-A710
SP-A900
13 7/8 in.
13 7/8 in.
13 1/4 in.
14 in.
18 in.
18 in.
23 3/4 in.
11 1/2 in.
11 1/2 in.
10 5/8 in.
11 7/8 in.
14 3/8 in.
14 3/8 in.
14 3/8 in.
6 15/16 in.
7 15/16 in.
10 1/2 in.
11 1/2 in.
14 1/2 in.
14 1/2 in.
14 1/2 in.
.100
70
1.9
92
2.6
114
2.1
110
1.2
156
3.3
195
4.6
197
2.8
251
3.0
293
3.3
413
3.8
413
3.8
512
5.7
714
7.2
907
5.7
w ww .t ms j .c o m
.125
68
1.9
88
2.7
110
2.2
106
1.2
155
3.3
194
4.7
192
2.9
246
3.0
287
3.3
405
3.7
405
3.7
501
5.6
701
7.2
896
5.8
Pressure in inches WG
.250
.375
57
49
2.4
3.1
75
59
3.0
3.6
97
95
2.4
2.7
88
1.6
154
152
3.7
4.3
191
187
5.1
5.6
167
133
3.1
3.4
227
210
3.4
4.4
257
231
3.6
3.9
351
305
3.7
4.3
351
306
3.7
4.3
439
392
5.5
5.4
653
588
7.0
6.8
841
773
6.1
6.2
Outlet
D
E
4 in. Diameter
3/4 in.
6 in. Diameter
1 1/4 in.
8 in.
6 in.
8 in.
8 in.
8 in.
8 in.
10 in.
8 in.
18 3/4 in.
8 in.
.500
39
3.6
45
4.1
94
2.8
.625
.750
1.000
30
4.9
91
3.6
85
4.4
50
5.4
149
4.5
184
5.8
147
5.0
181
6.0
138
5.3
166
6.3
92
5.8
128
6.6
185
4.6
207
4.1
157
4.9
175
4.5
119
5.2
124
5.5
325
4.7
485
6.7
701
6.2
320
6.7
31
G REENH ECK
Model CSP
Inline Cabinet Exhaust Fan
F
Model CSP inline cabinet fans are designed for clean air
application where low sound levels are desired. They can be
used for supply, exhaust or return applications within a duct
system. Their low sound levels are achieved through quiet
running forward curved wheels and an acoustically insulated
housing. The outlet duct includes an integral aluminum
backdraft damper that is easily converted from horizontal
to vertical discharge positions. Model CSP fans are UL listed
and licensed to bear the AMCA Certified Ratings Seals
for air and sound performance.
Model
32
RPM
AMPS
E
1400
1.10
100
CSP-A290
1050
0.71
80
CSP-A390
1000
1.87
139
CSP-A410
1000
1.87
135
CSP-A510
1070
3.11
217
CSP-A710
1080
4.40
325
CSP-A900
950
4.87
328
CSP-A1050
1095
6.65
455
CSP-A1410
1450
7.80
822
G
D
D
C
A
B
A
F
Inlet
D (diameter)
Inlet
FxG
C
E
B
A
Model
A
B
C
D
E
F
G
CSP-A190
13 1/4 in.
10 5/8 in.
10 1/2 in.
8 in.
6 in.
12 in.
9 1/4 in.
CSP-A290
14 in.
10 7/8 in.
11 1/4 in.
8 in.
8 in.
12 7/8 in.
10 in.
CSP-A410, 510
18 in.
14 3/8 in.
14 1/2 in.
8 in.
8 in.
16 7/8 in.
13 1/4 in.
CSP-A710
18 in.
14 3/8 in.
14 1/2 in.
10 in.
8 in.
16 7/8 in.
13 1/4 in.
CSP-A900, 1050, 1410
23 3/4 in.
14 3/8 in.
14 1/2 in.
18 3/4 in.
8 in.
22 5/8 in.
13 1/4 in.
Watts
CSP-A190
E
C
G
Stock Notes
• Units are stocked with 115/60/1 motors
• All CSP fans require 5 watt speed controller,
Model CSP-A1050 and CSP-A1401 require 10W
speed controller
Available Accessories
• Wall and discharge accessories
• Vibration isolation kit
• Speed control
B
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
0
215
2.3
318
1.6
447
2.2
447
2.2
545
3.1
737
3.2
908
3.7
1182
6.3
1584
6.3
.100
202
2.0
299
1.7
411
2.1
411
2.1
514
2.9
698
3.3
852
3.8
1110
6.1
1543
6.2
.125
198
2.2
292
1.8
403
2.2
403
2.2
506
2.8
688
3.2
840
3.8
1093
5.9
1533
6.2
Pressure in inches WG
.250
.375
180
159
2.7
2.9
265
248
2.6
3.3
364
316
2.5
2.7
364
317
2.5
2.7
464
405
2.8
2.7
635
566
3.3
2.7
782
714
4.0
4.0
1013
922
5.8
6.0
1483
1439
6.3
6.5
76 3- 544- 5442
.500
121
3.0
229
4.0
217
2.7
217
2.7
324
3.1
474
2.5
631
4.1
832
6.0
1395
6.8
.625
.750
201
3.7
144
3.4
1.000
334
2.7
743
5.5
1345
7.2
w w w .t ms j .c o m
1293
7.6
1181
8.6
G REENH ECK
D
Model RJ
C
Pitched Roof Cap
Stock Notes
• Steel construction with black enamel finish
• Integral flashing flange
• Built-in birdscreen and damper
B
C
E
A
A
Model
RJ-6 x 9
RJ-10 x 10
For use with
SP/CSP fans
B90-B200
A50-A390
A410-A1550
B
D
E
18 3/4¨
14 1/4¨
14 1/2¨
10 3/8¨
6 1/2¨
27 1/2¨
15 3/4¨
23 5//8¨
9 1/2¨
B
Hooded Wall Cap
G
D
C
C
18 1/2¨
Model WC
Stock Notes
• Aluminum construction
(WC-4, WC-6, WC-8 only)
• Steel construction with black
enamel finish
(WC-10x3, WC-8x8 only)
• For outside wall applications
• Built-in damper and birdscreen
D
E
A
B
F
B
C
A
IP
A
E
A
B
C
D
E
WC-4
For use with
SP/CSP fans
C-50, B50-B80
6 1/2¨
6¨
4¨
2 3/4¨
8 1/2¨
WC-6
B90-B200, A50-A190
8¨
8¨
6¨
4 1/8¨
8 1/2¨
WC-8
A200-A510
11¨
11¨
8¨
5 1/8¨
8 1/2¨
WC-10x3
A50-A290
5 1/2¨
12 3/4¨
3 1/2¨
10 1/4¨
WC-8x8
A200-A510
10 1/4¨
10 1/4¨
8 1/4¨
8 1/4¨
Model
D
E
WC-18X8
F
G
11 1/8¨
4 1/4¨
5¨
8 1/4¨
6 3/4¨
5¨
B
D
C
G
F
IP
A
E
WC-18X8
763-544-5442
w ww .t ms j .c o m
33
G REENH ECK
Model RDC
Round Duct Connectors
Stock Notes
• Replaces the standard square discharge duct
connector and damper
• Uses existing mounting holes
• Galvanized steel construction
• Does NOT include a damper
Model
For use with SP/CSP fans
Diameter
RDC-6
A110-A190
6¨
RDC-8
A200-A510
8¨
Model 5W and 10W
Speed Controllers
Stock Notes
• 5W – Applications up to 5 amps. Requires a 2 x 4
handy box by others
• 10W – Applications up to 10 amps. Requires a 4 x 4
handy box by others
• Speed controls can operate more than one fan as
long as the total amperage of the fans does not
exceed the control rating
Model BVE-157
A
Brick Vent
Stock Notes
• Extruded aluminum construction
• Heavy gauge 4¨ deep frame
• Includes insect screen
• Clear anodized finish
B
A
B
C
15 5/8¨
7 3/4¨
4¨
C
34
76 3- 544- 5442
w w w .t ms j .c o m
G REENH ECK
Fusible Links
Model
Size
Hooks
165B
Small
Yes
165D
Large
Yes
212B
Small
Yes
212D
Large
Yes
165E
X
X
212E
X
X
286E
X
X
Direct Fired
Make-Up Air Parts
GFC #
Part #
452942
18117
Maxon Flame Rod
Length
10¨
452943
23739
Maxon Spark Rod
4¨
383368
18075
Maxon Spark Rod
8¨
461660
13093
Eclipse Flame Rod
3.75¨
461661
17071
Eclipse Spark Rod
3.5¨
Insulated Access Doors
Size
6¨ x 6¨
8¨ x 8¨
10¨ x 10¨
12¨ x 12¨
14¨ x 14¨
Size
16¨ x 16¨
18¨ x 18¨
20¨ x 20¨
22¨ x 22¨
24¨ x 24¨
Paddle/Destratification Fan
Stock Notes
• 120V, 48¨
• EnviroFan Model 48F-9, white with 10¨ downrod
763-544-5442
w ww .t ms j .c o m
35
G REENH ECK
Model FD-150
Static Fire Damper
Stock Notes
• UL 555 Classified
• Type A curtain (blades in air stream)
• Vertical or horizontal installation
• Spring loaded
• 165 degree fusible link
• Galvanized steel construction
• Mill finish
Height
Width
6
4
6
8
10
X
8
10
12
14
X
X
X
X
16
18
20
24
30
32
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
12
X
14
16
18
20
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
48
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
22
X
24
X
30
X
36
X
Model FDR-510
True Round Static Fire Damper
Stock Notes
• Includes (2) retainer plates
• For wall/floor thickness up to 8.5¨
• 165˚ fusible link
• Diameter sizes: 6¨, 8¨, 10¨, 12¨, 14¨
36
36
76 3- 544- 5442
w w w .t ms j .c o m
G REENH ECK
Model FSD-211
Fire Smoke Dampers - 120V with Angles
UL555S Leakage Class I, 1 1/2 Hour Fire Resistance Rating
Standard Construction
Frame:
5¨ x 1¨ galvanized steel hat channel with
reinforced corners. A low profile head and
sill are used on sizes less than 17¨ high to
maximize free area and performance.
Blades:
16 ga. galvanized steel, reinforced with
3 longitudinal structurally designed vee’s.
Seals:
Extruded silicone rubber blade seals.
Flexible stainless steel jamb seals.
Linkage:
Concealed in jamb.
Size W x H
8¨ x 8¨
10¨ x 10¨
12¨ x 6¨
12¨ x 8¨
12¨ x 12¨
14¨ x 14¨
Closure Device: UL listed 165˚ F RRL
16¨ x 8¨
Axles:
1/2¨ diameter plated steel
16¨ x 16¨
Bearings:
Bronze sleeve type
18¨ x 18¨
Sleeve Length:
21¨
20¨ x 20¨
24¨ x 12¨
W&H dimensions furnished approximately 1/4¨ undersize
24¨ x 24¨
Model OFSD-211
Out of Wall Fire Smoke Dampers - 120V with Angles
UL555S Leakage Class I, 1 1/2 Hour Fire Resistance Rating
Stock Notes
• 12¨ x 12¨ size
Standard Construction
Frame:
5¨ x 1¨ galvanized steel hat channel with
reinforced corners. A low profile head and
sill are used on sizes less than 17¨ high.
Blades:
16 ga. galvanized steel, reinforced with
3 longitudinal structurally designed vee’s.
Seals:
Extruded silicone rubber blade seals.
Flexible stainless steel jamb seals.
Linkage:
Concealed in jamb.
Closure Device: UL listed 165˚ F RRL
Axles:
1/2¨ diameter plated steel
Bearings:
Bronze sleeve type
Sleeve:
Galvanized; wrapped with thermal blanket
Sleeve Length:
16¨
W&H dimensions furnished approximately 1/4¨ undersize.
Oversize wall opening as follow: Nominal damper size plus 3/8¨
763-544-5442
w ww .t ms j .c o m
37
G REENH ECK
Model FSDR-511
Round Combination Fire
Smoke Dampers - 120V with Angle
UL555S Leakage Class I, 1 1/2 Hour Fire Resistance Rating
Model FSDR-511 is a round combination fire smoke
damper. The FSDR-511 has been qualified to 3,000 ft/min
and 4¨ wg for operation and dynamic closure in emergency
fire smoke situations.
Stock Notes
• Closure device 165˚ F RRL
• Two retainer plates
• Sizes: 6¨, 8¨, 10¨, 12¨, 14¨
Model CRD-2
Ceiling Radiation Fire Damper
Stock Notes
• UL 555 Classified
• 165 degree fusible link
• Galvanized steel construction
• Mill finish
• Sizes: 6¨, 8¨, 10¨, 12¨, 14¨
Model QB-24
Thermal Insulating Blanket
Stock Notes
• Mineral wool material
• Required for use with CRD-2 dampers and
24¨ x 24¨ lay-in diffusers for U.L. fire rated ceilings
• Module size = 24¨ x 24¨
38
76 3- 544- 5442
w w w .t ms j .c o m
G REENH ECK
Model ESD-435
Aluminum Louvers
Stock Notes
• Louvers are 1/4¨ undersized with channel frame
• Water penetration begins at 1151 FPM free area velocity
Size W x H
Free Area (ft2)
Max CFM
12¨ x 12¨
0.29
330
14¨ x 14¨
0.43
495
16¨ x 16¨
0.64
735
18¨ x 18¨
0.83
955
20¨ x 20¨
1.12
1285
24¨ x 12¨
0.67
770
24¨ x 16¨
1.02
1170
24¨ x 18¨
1.15
1320
24¨ x 24¨
1.72
1975
30¨ x 30¨
2.97
3415
32¨ x 16¨
1.41
1620
32¨ x 32¨
3.38
3890
36¨ x 24¨
2.69
3095
5040
36¨ x 36¨
4.38
48¨ x 24¨
3.66
4210
48¨ x 48¨
8.44
9710
Standard Construction
Frame:
Heavy gauge 6063T5 extruded aluminum,
4¨ x .081¨ nominal wall thickness.
Blades:
Drainable design, heavy gauge extruded
6063T5 aluminum, .081¨ nominal wall
thickness, positioned at 37.5º angles on
approximately 3 1/4¨ centers.
Birdscreen:
3/4¨ x .051¨ flattened expanded aluminum
in removable frame. Screen is mounted on
inside (rear).
Finish:
Cleaned mill finish.
Model VCD-23
Opposed Blade Dampers
Low Leak Construction
Stock Notes
• Dampers are 1/4¨ undersized from list size
• Optional limit / end switch with bracket
Size W x H
Belimo Model
12¨ x 12¨
TFB
14¨ x 14¨
TFB
16¨ x 16¨
TFB
18¨ x 18¨
TFB
20¨ x 20¨
TFB
24¨ x 12¨
TFB
24¨ x 16¨
TFB
24¨ x 18¨
TFB
24¨ x 24¨
TFB
30¨ x 30¨
FSLF
32¨ x 16¨
TFB
32¨ x 32¨
FSNF
36¨ x 24¨
FSNF
36¨ x 36¨
FSNF
48¨ x 24¨
FSNF
48¨ x 48¨
AFBUP
763-544-5442
Standard Construction
Frame:
5¨ x 1¨ galvanized steel hat channel.
Reinforced corners. Low profile head and
sill are used on sizes less than 17¨.
Blades:
16 ga. galvanized steel, reinforced with
3 longitudinal structurally designed vee’s.
Linkage:
Side linkage out of air stream
(concealed in frame).
Seals:
Extruded vinyl blade seals.
304 stainless steel jamb seals.
Axles:
1/2¨ diameter plated steel.
Removable control shaft extends 6¨.
Bearings:
Synthetic (Acetal) sleeve type.
w ww .t ms j .c o m
39
G REENH ECK
Model VCDR-53
Round Control Damper
Low Leak Construction
Stock Notes
• Sizes: 6¨, 8¨, 10¨, 12¨, 14¨
Standard Construction
Frame:
Reinforced 20 ga. galvanized steel
Blades:
Double skin galvanized steel
Axles:
1/2¨ diameter plated steel
Bearings:
Stainless steel
Seals:
EPDM blade seal
Belimo Actuators
Stock Notes
• All actuators are 2-position spring return
40
Model
Min. Torque Rating
24 Volt
24 Volt with Endswitch
120 Volt
120 Volt with Endswitch
TFB
22 in-lbs
X
X
X
X
FSLF
30 in-lbs
X
X
X
FSNF
70 in-lbs
X
X
X
AFB
180 in-lbs
X
X
X
76 3- 544- 5442
w w w .t ms j .c o m
41
Versatec Base
Commercial - to 6 Ton
Versatec Basa exceeds
ASHRAE 90.1 efficiencies
Geothermal / Water Source Heat Pump
The Versatec Base is engineered to offer high
efficiency operation while maintaining a small cabinet
footprint and an impressive list of value-added features.
With its compact design and ability to perform optimally
in both water loop and geothermal applications, the
Versatec Base is an ideal solution for both retrofit
and new construction applications.
The Versatec Base model exceeds ASHRAE 90.1
efficiencies while utilizing environmentally friendly
R410A refrigerant. It is available in a wide selection
of capacities (006-070 MBtuh output) to offer
unmatched application flexibility.
Key Features
• Compressor: Reciprocating single speed, in commercial voltages. Compressor blanket option
available for improved noise reduction.
• Blower Inlet Rings: Allow for easy motor and blower removal without disconnecting from
the unit duct work.
• Filter: 1¨ MERV 4 disposable filter with filter rail is standard while a 2¨ pleated MERV 13
and deluxe filter rack are optional. Field switchable from 1¨ or 2¨ filters.
• Cabinet: Small footprint ideal for retrofit applications. Heavy gauge, environmentally responsible
galvanized steel for maximum corrosion resistance. Standard foil-faced cabinet insulation for
improved air quality and easy cleaning.
• Blower Motor: PSC blower motors provide high efficiency while allowing quiet operation
and wide range of airflow selections. X13 blower motors are stocked above 1 Ton capacity.
• Controls: Aurora microprocessor control is standard.
• Drain Pan: Corrosion-resistant stainless steel drain pan.
• Water Valve: Optional factory-installed, low pressure drop (high Cv) water solenoid valve
for variable speed pumping applications. Feature complies with ASHRAE 90.1 standard requirement
for WSHP. Pair with optional Automatic Water Flow Control Valve to ensure proper water flow rate.
• Aluminum Air Coil: An aluminum air coil is featured in all Versatec Base units to provide
exceptional durability and high efficiencies.
42
W A TER- FURNA CE
Left Return
Versatec Base
C
Horizontal 1/2 to 6 ton
B
A
Model
A
B
C
006-012*
19.2
35.0
12.1
015-018*
22.5
35.0
17.2
024-030
22.5
42.0
17.2
036
22.5
42.0
19.2
042-048
22.5
45.0
19.2
060
25.5
48.0
21.2
070
25.5
53.0
21.2
Cool capacities based upon
80.6˚F DB, 66.2˚F WB entering
air temperature.
Heating capacities based upon
68˚F DB, 59˚F WB entering
air temperature.
AHRI/ISO 13256-1 PERFORMANCE RATINGS
PSC Motor
AHRI/ASHRAE/ISO 13256-1
English (IP) Units
Flow Rate
Model
Water Loop Heat Pump
Cooling EWT 86°F
Ground Water Heat Pump
Heating EWT 68°F
Cooling EWT 59°F
Ground Loop Heat Pump
Heating EWT 50°F
Cooling EWT 77°F
Heating EWT 32°F
gpm
cfm
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
COP
006
2.0
250
7,100
13.4
8,000
4.3
8,400
21.3
6,800
3.8
7,400
15.5
5,400
3.2
009
3.0
350
8,100
12.2
11,400
4.6
9,900
19.2
9,600
4.0
8,900
14.5
7,600
3.4
012
3.0
400
10,200
12.2
15,200
4.4
12,200
18.2
12,600
3.9
11,200
14.2
10,200
3.5
09/26/12
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon 208V operation
Variable Speed ECM, 5-Speed ECM Motor
AHRI/ASHRAE/ISO 13256-1
English (IP) Units
Flow Rate
Model
015
Water Loop Heat Pump
Cooling EWT 86°F
Ground Water Heat Pump
Heating EWT 68°F
Cooling EWT 59°F
Ground Loop Heat Pump
Heating EWT 50°F
Cooling EWT 77°F
Heating EWT 32°F
gpm
cfm
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
COP
4.0
500
13,800
13.2
16,100
4.6
16,000
21.0
13,400
4.1
14,200
15.7
11,000
3.3
018
5.0
600
17,300
14.2
19,000
4.5
19,800
22.0
16,000
3.9
18,000
16.2
12,600
3.3
024
6.0
800
22,900
13.6
26,000
4.7
27,000
20.8
22,600
4.2
24,500
15.6
17,000
3.5
030
8.0
900
28,400
14.7
34,000
4.7
33,500
22.5
28,000
4.2
30,000
17.0
21,000
3.5
036
9.0
1150
34,500
14.5
43,800
4.9
40,000
23.0
35,600
4.4
36,000
17.0
26,000
3.5
042
11.0
1400
39,200
14.2
51,000
4.9
47,000
22.0
41,400
4.5
42,000
16.6
30,500
3.5
048
12.0
1600
47,200
14.0
59,000
4.8
57,000
21.0
48,000
4.2
49,500
16.0
36,500
3.5
060
15.0
1900
57,000
14.0
66,000
4.6
67,000
22.0
55,000
4.2
58,000
16.0
43,000
3.5
09/26/12
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon 208V operation
*UBH006-012 offers a lifted drain pan that allows the trap to be installed without additional ceiling height required.
763-544-5442
w ww .t ms j .c o m
43
W A TER- FURNA CE
The vertical unit is not a TMS Stock item,
but is available on a 3-day quick build.
Left Return
Versatec Base
Vertical 1/2 to 6 ton
Model
006-012
015-018
024-030
036
042-048
060
070
A
19.2
22.5
22.5
22.5
22.5
25.5
25.5
B
19.2
22.2
22.2
26.2
26.2
31.2
31.2
C
24.2
30.2
36.2
40.2
44.2
44.2
48.2
C
AHRI/ISO 13256-1 PERFORMANCE RATINGS
B
PSC Motor
A
AHRI/ASHRAE/ISO 13256-1
English (IP) Units
Flow Rate
Model
Water Loop Heat Pump
Cooling EWT 86°F
EER
Btu/h/W
Ground Water Heat Pump
Heating EWT 68°F
Capacity
Btu/h
Cooling EWT 59°F
Ground Loop Heat Pump
Heating EWT 50°F
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
Cooling EWT 77°F
Heating EWT 32°F
gpm
cfm
Capacity
Btu/h
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
COP
006
2.0
250
7,100
13.4
8,000
4.3
8,400
21.3
6,800
3.8
7,400
15.5
5,400
3.2
009
3.0
350
8,100
12.2
11,400
4.6
9,900
19.2
9,600
4.0
8,900
14.5
7,600
3.4
012
3.0
400
10,200
12.2
15,200
4.4
12,200
18.2
12,600
3.9
11,200
14.2
10,200
3.5
015
4.0
500
13,200
12.5
15,400
4.5
16,000
20.0
13,000
4.0
14,000
15.3
10,400
3.2
018
5.0
600
17,300
13.4
19,000
4.3
19,800
20.5
16,000
3.7
18,000
15.4
12,600
3.2
024
6.0
800
22,900
13.0
26,000
4.5
27,000
19.8
22,600
4.0
24,500
14.8
17,000
3.3
030
8.0
1000
28,400
13.8
34,000
4.5
33,500
21.0
28,000
4.0
30,000
16.0
21,000
3.3
036
9.0
1150
34,500
14.0
43,800
4.7
40,000
22.0
35,600
4.2
36,000
16.3
26,000
3.3
042
11.0
1400
39,200
13.2
51,000
4.7
47,000
20.4
41,400
4.3
42,000
15.2
30,500
3.3
048
12.0
1600
47,200
13.0
59,000
4.6
57,000
19.8
48,000
4.0
49,500
15.0
36,500
3.3
060
15.0
1900
57,000
13.5
66,000
4.3
67,000
21.0
55,000
4.0
58,000
15.2
43,000
3.3
070
18.0
2100
66,000
14.0
80,000
4.5
75,000
20.5
64,000
4.0
68,000
15.6
49,000
3.3
09/26/12
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon 208V operation
Variable Speed ECM, 5-Speed ECM Motor
AHRI/ASHRAE/ISO 13256-1
English (IP) Units
Flow Rate
Model
Water Loop Heat Pump
Cooling EWT 86°F
Ground Water Heat Pump
Heating EWT 68°F
EER
Btu/h/W
Capacity
Btu/h
Cooling EWT 59°F
Ground Loop Heat Pump
Heating EWT 50°F
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
Cooling EWT 77°F
COP
Capacity
Btu/h
EER
Btu/h/W
Capacity
Btu/h
gpm
cfm
COP
015
4.0
500
13,800
13.2
16,100
4.6
16,000
21.0
13,400
4.1
14,200
15.7
11,000
3.3
018
5.0
600
17,300
14.2
19,000
4.5
19,800
22.0
16,000
3.9
18,000
16.2
12,600
3.3
024
6.0
800
22,900
13.6
26,000
4.7
27,000
20.8
22,600
4.2
24,500
15.6
17,000
3.5
030
8.0
900
28,400
14.7
34,000
4.7
33,500
22.5
28,000
4.2
30,000
17.0
21,000
3.5
036
9.0
1150
34,500
14.5
43,800
4.9
40,000
23.0
35,600
4.4
36,000
17.0
26,000
3.5
042
11.0
1400
39,200
14.2
51,000
4.9
47,000
22.0
41,400
4.5
42,000
16.6
30,500
3.5
048
12.0
1600
47,200
14.0
59,000
4.8
57,000
21.0
48,000
4.2
49,500
16.0
36,500
3.5
060
15.0
1900
57,000
14.0
66,000
4.6
67,000
22.0
55,000
4.2
58,000
16.0
43,000
3.5
070
18.0
2100
66,000
14.6
80,000
4.7
75,000
22.0
64,000
4.2
68,000
16.6
49,000
3.5
09/26/12
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon 208V operation
*UBH006-012 offers a lifted drain pan that allows the trap to be installed without additional ceiling height required.
44
Heating EWT 32°F
Capacity
Btu/h
76 3- 544- 5442
w w w .t ms j .c o m
45
A RM S TRONG
Model AMC-1ACO/AMC-1AVC
All-in-one Monitor
• All-in-one package for CO Monitoring AMC-1ACO
• All-in-one package for CO/NO2 Monitoring AMC-1AVC
• Electrochemical sensor eliminates nuisance alarms
• Two relays with ratings up to 10A @ 250 VAC Res. Max
• RS 232 COM part for logging and trending
• 115 VAC
• 50 ft. Sensor Radius
• 7,500 sq. ft. Coverage Area
Model AMC-VT-221F91AG (CO)
All-in-one Monitor
• All-in-one package for CO Monitoring
• Electrochemical sensor eliminates nuisance alarms
• Single trip point relay with ratings up to 2A @ 30 VDC Res. Max
• 4-20ma output signal
• 24VAC or 24VDC
Model AMC-1AD1
Single Zone Multidrop Gas Monitor
• Requires remote AMC 122X sensors
• Up to 8 AMC 122X series multidrop modules per zone
• 2 relays with ratings up to 10A @ 250 VAC Res.
• RS 232 COM part for logging and trending
Model AMC-1228-20/AMC-1222
Gas Sensor Module
• Use with AMC/1AD1 Panel
• Electrochemical sensor eliminates nuisance alarms
• Three wire 18 awg shielded
46
76 3- 544- 5442
w w w .t ms j .c o m
47
Q - M A RK
Model AWH
Architectural Heavy Duty Wall Heaters
Stock Notes
• Integral thermostat
for quick installation
• Thermal overheat protector
• Built-in power disconnect switch
• Built-in fan delay switch
• Permanently lubricated totally
enclosed fan motor
Model
Watts
Voltage
Phase
AWH4404
4000/3000
240/208
1
AWHSM
Surface mount frame - 15 3/8¨ W x 19 3/16¨ H x 3 3/4¨ D
Accessories
AWH4408
4000/2000
208
1
AWHS2
2¨ Semi-recess frame 15 3/8¨ W x 19 3/16¨ H x 2¨ D
AWH4508
4800
208
1
AWH45083
4800
208
3
Model MUH
Unit Heater
Stock Notes
• Heavy gauge die-formed steel housing
• Advanced pull-through air flow design
• Completely enclosed fan motor
• Individually adjustable discharge louvers
to control air flow
Model
Watts
Voltage
Phase
MUH0581
5000
208
1&3
Accessories
UHMT1
B10
48
Single pole stat Range 40F - 85F
Mounting bracket
76 3- 544- 5442
w w w .t ms j .c o m
49
S TERL I N G R A DI A TOR
C-44 Element
Stock Notes
• 1¨ cu. Tube
• 4 1/4¨ x 4 1/4¨ Aluminum Fins
• 40 Fins/foot
Available Lengths
3˙
4˙
5˙
6˙
7˙
JVB-S14 16ga. Slope Top Cover
Stock Notes
• Prime Finish
• 14¨ H x 5 5/16¨ D
Available Lengths
2˙
3˙
3.5˙
4˙
5˙
6˙
7˙
Modular Panels
Modular Panel in T-bar Ceiling
Stock Notes
• 2˙ x 2˙ and 2˙ x 4˙ – 6-pass
• White Finish
• 1¨ Insulation
• Optional plaster frames available for gyp ceiling
50
76 3- 544- 5442
w w w .t ms j .c o m
TM S JOH NS ON
Terms
Net 30 days to qualified customer. Balances over 60 days subject to credit hold.
All orders subject to approval. Prices are subject to change without notice.
Return Policy
Special orders, which are not stock, cannot be returned for credit.
Stockable items can only be returned under the following conditions.
1. Prior approval from TMS Johnson, Inc. Along with a copy of invoice on which material was sold.
2. Material must be in saleable condition subject to inspection by TMS Johnson, Inc.
3. 15% restocking charge or $25.00, whichever is greater, for invoices dated less than 30 days.
4. Credit amount to be determined by original selling price. Materials returned due
to TMS Johnson, Inc. error will not be subjected to restocking charge.
TMS Johnson, Inc.
2908 Nevada Avenue North
New Hope, MN 55427
763-544-5442
w ww .t ms j .c o m
51
TM S JOH NS ON
2014 product line
52
Indoor Air Pollutants
Reduction Equipment
Unique Air Distribution Products
Intelligent Measurement Solutions
Airflow Measurement and Control
Hazardous Gas Liquid
and Material | Monitoring
Control Dampers and
Architectural Louvers
Filters | Media and Housings
Custom Air Pollution Control Systems
Carbon Monoxide Exhaust
Welding Fume Exhaust
Dust Collectors
Inline Duct Fans | Iris Dampers
Industrial Fans
Fabric Air Dispersion Products
Custom Air Handling Units
Packaged Rooftop AHUs
Flexible Duct and Fittings
Variable Frequency Drives
Centrifugal and Vane Axial Fans |
Dampers and Louvers
Energy Recovery | Fans and Ventilators
Kitchen Ventilation Systems
Laboratory Exhaust Systems | Make up Air Units
Packaged 100% Outside and Return Air Units
Hot and Chilled Water Coils
Hays Fluid Controls
76 3- 544- 5442
w w w .t ms j .c o m
TM S JOH NS ON
Commercial / Industrial High Volume
Low Speed Destratification Fans
Commercial and Industrial
Ceiling Fans Air Curtains
Packaged RTU | Commercial
Controls Split Systems
Oval and Spiral Ductwork
Cable Operated Remote Dampers
Actuators | Electric Duct Heaters
Humidifiers | Actuated Valves
Commercial / Residential
HRV’s and ERV’s
Energy Recovery Pool
Dehumidification Equipment
Silencers | Displacement Ventilation | Grilles,
Registers, and Diffusers | Security Products
Specialized Environments | Terminal Units
Underfloor Products | Sound Control
Direct and Indirect Gas-Fired Make up Air Units
Air Rotation Units | Infrared Heaters
Air Curtains | Infrared Heaters | Electric
Baseboard, Cabinet, Ceiling Wall Heaters |
Radiant Ceiling Panels
Roof Curbs | Equipment Rails
Pipe and Duct Pedestals
Fiberglass Reinforced Plastic Duct | Products
Dust Control Equipment
Hydronic Heating Products
Air Purification Systems
Kitchen Exhaust Filtration Systems
Laboratory and Hospital Monitors
and Controls
Water Source Heat Pumps and Chillers
763-544-5442
w ww .t ms j .c o m
53
2908 Nevada Avenue North
New Hope, Minnesota 55427
763-544-5442
www.tmsj.com