cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:12 Page 1 LX Range EN 54-23 Visual Alarm Devices Low Current, Maximum Coverage cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:12 Page 2 Eaton and Cooper united. Energizing a world that demands more. We deliver: s Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable s Hydraulic and electrical solutions that enable machines to deliver s Aerospace solutions that make aircraft lighter, safer and less costly s Vehicle drivetrain and powertrain solutions that deliver more power more productivity without wasting power to operate, and help airports operate more efficiently to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering business worldwide !SAGLOBALDIVERSIFIEDPOWERMANAGEMENTCOMPANYWE HELPCUSTOMERSWORLDWIDEMANAGETHEPOWERNEEDEDFOR BUILDINGSAIRCRAFTTRUCKSCARSMACHINERYANDBUSINESSES %ATONSINNOVATIVETECHNOLOGIESHELPCUSTOMERSMANAGE ELECTRICALHYDRAULICANDMECHANICALPOWERMORERELIABLY EFFICIENTLYSAFELYANDSUSTAINABLY 7EPROVIDEINTEGRATEDSOLUTIONSTHATHELPMAKEENERGY INALLITSFORMSMOREPRACTICALANDACCESSIBLE 7ITHSALESOFBILLION%ATONHASAPPROXIMATELY EMPLOYEESAROUNDTHEWORLDANDSELLSPRODUCTS INMORETHANCOUNTRIES Eaton.com cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:12 Page 3 Cooper Safety Fire Systems Based in Doncaster, Cooper Safety Fire Systems manufacture and supply complete fire systems, not just individual components. A complete system can be specified from a single source, confident in the knowledge that all components have been specifically designed and tested to ensure that they are all fully compatible with each other and will function as a complete fire detection and alarm system. Our people are the heart of Cooper Safety Fire Systems - we have the talent and the infrastructure to serve our customers to the highest standard. Approvals and Certification Our dedicated approvals department is committed to ensuring all Cooper Safety Fire Systems products are third party certified and approved to comply with statutory legislation standards. Our products are assessed by Europe’s leading testing laboratories including BRE Global and CNPP and are tailored for a variety of geographical locations, through listings with local notified bodies such as VdS, NF and LPCB. New European Standard - EN 54-23 CERTIFIED TO EN54-23 From 31st December 2013 a new beacon standard, EN 54-23 will become mandatory across Europe where Construction Product Regulation (CPR) applies. It directly affects the use of visual alarm devices (VADs) in fire detection and alarm systems for non-domestic premises. Its purpose is to standardise the requirements, test methods and functional criteria of VADs to ensure that their visual performance is measured and presented in a uniform manner. Cooper Fire’s LX range has been designed to comply with the new EN 54-23 standard. With current consumption as low as 10mA, the range has been developed to provide the lowest current consumption with the highest possible coverage. Three years in the making, the LX range, available for wall and ceiling applications, features a number of patented technologies including an innovative lens and flash pattern. Further information on the new beacon standard and the LX range can be found on the Cooper Safety Fire Systems website, www.cooperfire.com 3 cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:12 Page 4 SOLISTA LX WALL - Red Flash 93mm 93mm The new Solista LX Wall product takes its slim line design cues from the popular Solista Maxi. Available in a red or white body colour and with a shallow base, deep base or U base, the Solista LX Wall is suitable for a variety of applications. 66mm 66mm 25mA DEEP BASE DEEP BASE 38mm SHALLOW BASE 38mm SHALLOW BASE IP65 9-60Vdc CERTIFIED TO EN54-23 W-2.4-7.5 RED FLASH EN 54-23 coverage reference W-2.4-7.5 Minimum Current consumption 10mA Body Colour Base Type Reference Red Red Red White White White Shallow Deep U Shallow Deep U FXSOLWRS FXSOLWRD FXSOLWRD FXSOLWWS FXSOLWWD FXSOLWWU SOLISTA LX CEILING - Red Flash 93mm 93mm The Solista LX Ceiling has a unique lens design that distributes the light in a cylindrical shape, achieving the required illumination of EN 54-23. Designed for installation at a height of 3m and with a discrete appearance, the device is ideal for a variety of applications. C-3-7.5 Minimum Current consumption 10mA EN 54-23 coverage reference C-3-7.5 Body Colour Base Type Reference White White Shallow Deep FXSOLCWS FXSOLCWD Key: 4 Voltage Sound Output (Typical tone 3) Light Output/ Coverage Volume Current (at 24Vdc) IP Rating Resistance 65mm 65mm RED FLASH 25mA DEEP BASE DEEP BASE 37mm SHALLOW BASE CERTIFIED TO EN54-23 37mm SHALLOW BASE IP33C 9-60Vdc cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:12 Page 5 RoLP LX WALL - Red Flash The RoLP LX Wall is ideal for dual use applications where a visual alarm device is required in addition to an audible alarm. Recommended for wall use and requiring just one installation point, the RoLP LX Wall is available to use with any standard RoLP sounder, including the high output RoLP Maxi sounder. CERTIFIED TO EN54-23 RED FLASH 18-28Vdc 102dB(A) 37mA W-2.4-7.5 EN 54-23 coverage reference W-2.4-7.5 135mm 135mm 95mm 95mm 95mm 95mm 2 x Ø20mm 2 x Ø20mm IP65 Minimum Current consumption 22mA Description Body Colour Reference RoLP Wall RoLP Wall RoLP Wall BASE RoLP Wall BASE Red White Red White FXROLPWR FXROLPWW FXROLPWR-B FXROLPWW-B 5 cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:13 Page 6 SYMPHONI LX WALL The Symphoni LX Wall base can be used in combination with any standard Symphoni sounder. The durable design ensures reliability and its high sound output makes it suitable for open areas or areas where there is higher than normal background noise. 147mm 147mm 106mm 106mm 92mm 92mm 2 x Ø20mm 2 x Ø20mm CERTIFIED TO EN54-23 RED FLASH 18-28Vdc 100dB(A) 30mA W-2.4-7.5 EN 54-23 coverage reference W-2.4-7.5 IP21C(s) IP66(WP) Minimum Current consumption 15mA Description Body Colour Reference Symphoni G1 LX Wall Symphoni G1 LX Wall Symphoni BASE Symphoni BASE Red White Red White FXSYG1WR FXSYG1WW FXSYR-B FXSYW-B SYMPHONI LX WP WALL The Symphoni LX WP Wall device offers a weatherproof alternative to the Symphoni LX Wall device. With an ingress protection rating of IP66, it is suited for wet and outdoor environments. 147mm 147mm 106mm 106mm 92mm 92mm 2 x Ø20mm 2 x Ø20mm CERTIFIED TO EN54-23 RED FLASH 18-28Vdc 100dB(A) 30mA W-2.4-7.5 EN 54-23 coverage reference W-2.4-7.5 IP21C(s) IP66(WP) Minimum Current consumption 15mA Description Body Colour Reference Symphoni G1 LX Wall Weatherproof Symphoni G1 LX Wall Weatherproof Symphoni BASE Weatherproof Symphoni BASE Weatherproof Red White Red White FXSYG1WR-WP FXSYG1WW-WP FXSYR-B-WP FXSYW-B-WP Key: 6 Voltage Sound Output (Typical tone 3) Light Output/ Coverage Volume Current (at 24Vdc) IP Rating Resistance cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:13 Page 7 Customer Assistance Europe calls may be made between: Monday - Friday 8:30am - 5:00pm The Customer Technical Support Team can be reached via: Phone: 01302 303350 Fax: 01302 303340 Email: info@cooperfire.com Online Resources Visit www.cooperfire.com for the following resources: - 24/7 online product support - Catalogue and literature - Product profiles - Datasheets, installation and user manuals © Copyright 2013 Cooper Safety Fire Systems Ltd All rights reserved Publication Ref: CFS-LX2013CAT-V1 September 2013 Version 1 7 cc2412 - LX Range A5 Brochure 2013_Layout 1 06/12/2013 16:13 Page 8 Head Office Cooper Safety Fire Systems Cooper Lighting and Safety Wheatley Hall Road Doncaster South Yorkshire DN2 4NB Tel: Fax: Email: +44 (0)1302 303999 +44 (0)1302 303333 sales@cooperfire.com Web: www.cooperfire.com Cooper Safety Jephson Court, Tancred Close Royal Leamington Spa Warwickshire, CV31 3RZ United Kingdom Tel: Fax: +44 (0)1926 439200 +44 (0)1926 439240 Web: www.cooper-safety.com Cooper Industries Unit F10, Maynooth Business Campus Maynooth, Ireland. www.cooperindustries.com CFS-LX2013CAT-V1