INSTALLATION INSTRUCTIONS For VuLite V6RL3K-WH and V6RL3K-WH-T24 WARNING: For your safety, read and understand these instructions completely before starting installation. Before installing this product, turn off electricity at fuse or circuit breaker box. NOTE: VuLite products are designed to meet the latest NEC requirements and are listed in full compliance with corresponding UL standards. Before attempting installation of any recessed lighting fixture or accessory, check your local electrical building code. This code sets the wiring and installation requirements for your locality and should be understood before starting work. SAVE THESE INSTRUCTIONS WARNING: Risk of fire or electric shock. • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. • The electrical rating of this product is 120VAC. The installer must determine whether they have 120V at the luminaire before installation. • Luminaires wiring, ballasts, or other electrical parts may be damaged when drilling for installation of reflector kit hardware. Check for enclosed wiring and components. • Reflector kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. • Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. VuLite V6RL3K-WH Retrofit LED Trim Compatibility The VuLite V6RL3K-WH LED trim is designed to work with most standard UL Listed 6” recessed incandescent housings. Compatibility can be determined by measuring the recessed housing as follows: A) Height: The housing must be at least 6-3/4” high B) Diameter: The housing inside diameter must be between 6” and 6-3/4” The recessed housing must also contain brackets to support the trim springs (see figure 1). If housing does not contain spring retaining brackets, contact factory to order an adapter kit. Recessed Housing Typical Spring Retaining Bracket VuLite V6RL3K-WH-T24 LED Downlight Module Compatibility: The VuLite V6RL3K-WH-T24 contains a connector that is designed to meet the high efficacy requirements of California Title 24-2008. The connector is only intended to be plugged into the mating connector in Juno housing part numbers IC23-LEDT24 and IC23R-LEDT24. Use of this module in other luminaires or removing the factory installed connector is not recommended and voids the product warranty. Dimming The VuLite V6RL3K-WH and V6RL3K-WH-T24 LED trims are compatible with many dimmers designed for incandescent or electronic low voltage loads. Contact Juno Lighting Group for a current list of compatible dimmers. Figure 1 Height Diameter 1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com © 2011 Juno Lighting LLC Rev 5/11 P2991 pg 1 of 2 INSTALLATION INSTRUCTIONS For VuLite V6RL3K-WH and V6RL3K-WH-T24 Installation CAUTION: Power to the luminaire must be turned off prior to installing these LED trims. Failure to do so can cause electric shock, which can result in injury or death. Step 5. Insert trim torsion springs into corresponding retaining brackets in recessed housing. Carefully push trim towards ceiling until the springs pull the trim tight. WARNING: This trim must be grounded as outlined in this instruction sheet. Failure to do so can result in electric shock or undesired operation. Step 6. Turn power back on to fixture. Step 1. Confirm the LED trim is compatible with the recessed housing as outlined previously in these instructions. Ground Terminal Ground Terminal Connector Ground Wire Socket Ground Wire Torsion Spring Step 2. (V6RL3K-WH only) Some recessed housings contain an adjustable plate or bracket that supports the socket. The socket must be detached from the plate/bracket, and the plate/bracket must be removed from the housing prior to installation of the trim. For detailed instructions on removing the plate or bracket, refer to manufacturer’s installation instructions. V6RL Trim V6RL-T24 Trim Figure 2 Remodel Style Recessed Housing Step 3. Screw the trim into the socket in the recessed housing (V6RL3K-WH) or connect the trim connector to the housing connector (V6RL3K-WH-T24). Ground Terminal from Trim Screw Step 4. Securely attach the ground wire terminal to any screw located in the recessed housing that fastens metallic components. Screws can commonly be found near the base of the recessed housing, where the socket mounting bracket was installed, or in the torsion spring bracket. If screws are not present in the recessed housing, contact a qualified electrician for assistance in determining a suitable ground. (see figures 3 & 4) Figure 3 New Construction Recessed Housing Screw Figure 4 Ground Terminal from Trim WARRANTY Juno Lighting Group warrants that its products are free from defects in material and workmanship for three years from date of purchase. Juno Lighting Group’s obligation is expressly limited to repair or replacement, without charge, at Juno Lighting Group’s factory after prior written return authorization has been granted. This warranty shall not apply to products which have been altered or repaired outside of Juno Lighting Group’s factory. This warranty is in lieu of all other warranties, expressed or implied, and without limiting the generality of the foregoing phrase, excludes any implied warranty of merchantability. Also, there are no warranties which extend beyond the description of the product on the company’s literature setting forth terms of sale. Product Services Phone (888) 387-2212 1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com © 2011 Juno Lighting LLC Rev 5/11 P2991 pg 2 of 2