ADDM. NO. MPC-1-1 ADDENDUM NO. MPC

advertisement
ADDENDUM NO. MPC-1
Architecture Engineering Planning
. Interiors
to the
6200 Aurora Avenue
Suite 210W
Des Moines, IA 50322
PROJECT MANUAL
AND
DRAWINGS
tel 515/276-8097
fax 515/252-0514
desmoines@dlrgroup.com
www.dlrgroup.com
for
SOUTHVIEW MIDDLE SCHOOL – PHASE 2
ANKENY COMMUNITY SCHOOL DISTRICT
ANKENY, IOWA
DLR GROUP PROJECT NO. 11-12102-00
March 20, 2012
NOTICE TO BIDDERS: The Project Manual and Drawings for the above referenced project are hereby amended
as follows:
CLARIFICATIONS
Some 95% Quality Assurance review sheets have been inadvertently distributed as part of some 100% bidding
drawing sets. Confirm that all sheets in the document set being reviewed are 100% bidding documents dated
March 8, 2012. Please contact Action Reprographics for any drawing sets that require replacement.
The following clarification note should be referred to for all project manuals and project drawings:
“Clarification: It is the Contractor’s responsibility to see that he has all pertinent information for bidding
this project. Because of mass production of the Project Manuals and Drawings, there may be some
misplaced or missing pages in the manuals. Should a page or pages be missing from the manuals, please
notify DLR Group and those pages will be supplied at no additional charge.”
PROJECT MANUAL –VOLUME 1
ITEM NO. 1
SECTION 011200 – MULTIPLE CONTRACT SUMMARY (Prepared by Story Construction)
A. Subparagraph 1.6.A.2.a. Delete Note 20).
B. Subparagraph 1.6.A.4.c. Add Note 17): “17) Contractor shall provide and install downspout storm drain
connection, hub adapter and steel grate as shown on Detail 1/C3.1. Concrete work to be completed by
Bid Package No. 25 Contractor.”
C. Subparagraph 1.6.D.4.n. Insert the word “new” before the word “ductwork” in the first sentence.
D. Subparagraph 1.6.D.4.o. Insert the words “Bid Package No. 151” before the word “Contractor” at the
beginning of the sentence.
E. Subparagraph 1.6.E.3.a. Add Note 5): “5) Contractor shall provide and install steel framing including,
but not limited to, HSS columns, channels, and angles for equipment screen and gates at Equipment Area.
Bid Package No. 75 Contractor to provide and install metal panels, trim, coping, flex flashing and wood
blocking for equipment screen and gates.”
ADDM. NO. MPC-1-1
F. Subparagraph 1.6.E.3.a. Add Note 6): “6) Contractor shall provide and install gate hardware for
equipment screen as shown on Details 51, 52 & 53/A10.2.”
G. Subparagraph 1.6.F.3.b. Add Note 1): “1) Contractor shall provide and install parabolic louver diffusers
in display cases as shown on Details 43, 44, & 46/A10.3.”
H. Subparagraph 1.6.F.5. Add paragraph h.: “Section 088100 – Fire Rated Glass and Framing Systems, as it
pertains to Contractors own Work.”
I.
Subparagraph 1.6.F.5.h. Add Note 1): “1) Contractor shall provide and install rated hollow metal frames.
Bid Package No. 84 Contractor shall provide and install fire-rated glazing at rated frames.”
J.
Subparagraph 1.6F.5.h. Add Note 2): “2) Contractor shall provide and install rated window kits complete
with glazing within rated door assemblies.”
K. Subparagraph 1.6.G.5.c. Add Note 2): “2) Contractor to provide and install metal panels complete with
trim, coping, flex flashing and wood blocking for equipment screen and gates at Equipment Area. Bid
Package No. 51 Contractor shall provide and install steel framing for equipment screen and gates and gate
hardware.”
L. Subparagraph 1.6.H.3.e. Add Note 1): “1) Contractor shall provide and install display case glazing.”
M. Subparagraph 1.6.H.3. Add paragraph g.: “Section 088100 – Fire Rated Glass and Framing Systems, as
it pertains to Contractors own Work.”
N. Subparagraph 1.6.H.3.g. Add Note 1): “1) Contractor shall provide and install fire rated glazing at rated
frames provided and installed by Bid Package No. 62 Contractor.”
O. Subparagraph 1.6.H.3.g. Add Note 2): “2) Bid Package No. 62 Contractor shall provide and install rated
window kits complete with glazing within rated door assemblies.”
P. Subparagraph 1.6.I.5.b. Delete Notes 4) and 5).
Q. Subparagraph 1.6.P.1. Add Note u.: “u. Contractor shall seal perimeter of all plumbing and mechanical
penetrations through STC-Rated Assemblies with acoustical sealant per Section 079200 Joint Sealants.”
R. Subparagraph 1.6.P.2.a. Replace Note 1) completely as follows: “1) Contractor shall core drill or saw-cut
and remove materials to create openings for its Work in existing Phase 1 wall, floor or roof construction.”
S. Subparagraph 1.6.P.3.a.5. Replace “GXXX” with “Equipment Area”.
T. Subparagraph 1.6.P.4.a. Replace Note 1) completely as follows: “1) Contractor shall infill and support
existing masonry accordingly for new or modified existing plumbing or mechanical openings in existing
Phase 1 masonry wall construction.”
U. Subparagraph 1.6.P.4.a. Delete Note 2).
V. Subparagraph 1.6.P.9. Delete Note g.
W. Subparagraph 1.6.P.10. Delete Note g.
X. Subparagraph 1.6.P.10.k. Replace “M6.1/” with “M1.3 and M5.1.”.
ADDM. NO. MPC-1-2
PROJECT MANUAL –VOLUME 2
ITEM NO. 2
SECTION 087100 – DOOR HARDWARE
A. Add paragraph 3.6.UU:
“UU. Heading 25 Doors: A123
1 1 1 ITEM NO. 3
EA HINGE EA ELECTRIC LOCK EXISTING HARDWARE
REMAINS CARD READER BY
SECURITY CONTRACT”
5BB1HW 4.5 X 4.5 TW8 (REPLACE EXISTING MIDDLE)
L9080EU
SECTION 237200 – AIR TO AIR ENERGY RECOVERY UNITS
A. Subparagraph 2.1.A.1: Add the following subparagraph:
“e.
Innovent”
ITEM NO. 4
SECTION 237433 – DIRECT FIRED MAKEUP AIR UNITS
A. Subparagraph 2.1.A: Add the following subparagraph:
“6.
Airedale”
ITEM NO. 5
SECTION 238126 – WATER SOURCE HEAT PUMPS
A. Subparagraph 2.1.A: Add the following subparagraph:
“6.
McQuay/FHP”
ITEM NO. 6 SECTION 271500 - COMMUNICATIONS CABLING
A. Paragraph 2.12 UNINTERRUPTIBLE POWER SUPPLY AND HORIZONTAL POWER
DISTRIBUTION
1. Delete paragraph 2.12.B in its entirety and substitute:
"B. UPS equipment shall be furnished by the owner."
2. Delete paragraph 2.12.C in its entirety.
ITEM NO. 7 SECTION 274100 - CLASSROOM AUDIO-VISUAL SYSTEMS
A. Delete Section 274100 in its entirety and substitute new section as per attachment "E1".
ADDM. NO. MPC-1-3
626
626
689
IVE
SCH
LCN
DRAWINGS
ITEM NO. 1 SHEET C1.1 – SITE DEMOLITION PLAN
A. Modify Drawing as shown on Attachment No. C1 to Addendum No. MPC-1 dated March 20, 2012.
ITEM NO. 2
SHEET C2.1 – SITE LAYOUT PLAN
A. Modify Drawing as shown on Attachment No. C2 to Addendum No. MPC-1 dated March 20, 2012.
ITEM NO. 3
ITEM NO. 4
SHEET C6.2 – SITE DETAILS
A. Detail 11/C6.2. Delete “Base Bid” from Detail title.
ITEM NO. 4
SHEET AD1.1 – DEMOLITION PLANS, FIRST & SECOND LEVELS
A. Revise note #12 in Demolition Plan Key Notes to the following:
“12.
ITEM NO. 5
Not Used.”
SHEET A1.5 – FLOOR PLAN, FIRST LEVEL – AREA G
A. Revise wall section indicator along grid line G1 of equipment screen wall
: Delete “24/A7.1” and substitute “25/A7.1”.
ITEM NO. 6
SHEET A7.2 – WALL SECTIONS
A. Clarification for Wall Section 53: Concrete footing at top of ramp is shown graphically too high. Refer
to Structural Drawings for top and bottom of footing elevations.
ITEM NO. 7
SHEET A10.3 – GENERAL BUILDING DETAILS
B. Clarification for Details 43, 44, 46: PL-2 finish on ¾” particle board at bottom of display cases.
ITEM NO. 8
SHEET S1.1 – STRUCTURAL DETAILS
A. Detail 53/S3.1, delete the text, “#4x1’-4” DOWEL @ 6” OC. DRILL & FORCE FIT DOWEL 4” INTO
EXISTING SLAB,” and substitute “#4x1’-4” DOWEL @ 1’-0” OC. DRILL & FORCE FIT DOWEL 4”
INTO EXISTING SLAB,”.
ITEM NO. 9
SHEET S1.2 – FOUNDATION PLAN – AREA E
A. At the north end of Corridor E131, near Ramp E130, modify foundation plan per attachment S1.
ITEM NO. 10 SHEET S1.3 – FOUNDATION PLAN – AREA G
A. Along the north wall of Industrial Tech G101, between Grids G2 and G6, delete the edge stiffeners on
both sides of the openings (three locations total).
B. Along the north wall of Mechanical G111, at louver opening L-G101, place 2-#6’s in one cell on both
sides of opening.
ADDM. NO. MPC-1-4
ITEM NO. 11 SHEET S2.3 – ROOF FRAMING PLAN – AREA G
A. Along the north wall of Industrial Tech G101, between Grids G2 and G6, delete the text, “ML3, T-PL,” in
its entirety over openings (three locations total).
B. Along the north wall of Mechanical G111, over the louver opening L-G101, add the text, “ML3, T-PL.”
ITEM NO. 12 SHEET M1.1 – HVAC PLAN, FIRST LEVEL – AREA D
A. Keyed note 1 of Keyed Notes, HVAC: Delete “33/M5.1” and substitute “33/M4.1”.
B. Note A of General Notes, HVAC: Delete “GENERAL”.
C. Note L of General Notes, HVAC: Delete “34/M5.1” and substitute “34/M4.1”.
ITEM NO. 13 SHEET M1.2 – HVAC PLAN, FIRST LEVEL – AREA E
A. Keyed note 1 of Keyed Notes, HVAC: Delete “33/M5.1” and substitute “33/M4.1”.
B. Note A of General Notes, HVAC: Delete “GENERAL”.
C. Note L of General Notes, HVAC: Delete “34/M5.1” and substitute “34/M4.1”.
ITEM NO. 14 SHEET M1.3 – HVAC PLAN, FIRST LEVEL – AREA G
A. Keyed note 1 of Keyed Notes, HVAC: Delete “33/M5.1” and substitute “33/M4.1”.
B. Note A of General Notes, HVAC: Delete “GENERAL”.
C. Note L of General Notes, HVAC: Delete “34/M5.1” and substitute “34/M4.1”.
D. Legend Notes: Add Keyed Note 10 as follows:
“10.
E.
Bottom of grille = 13’-4” AFF. Center grille over door opening below. Install grille with fins
angled up to block view into ductwork from the floor level.”
HVAC PLAN, FIRST LEVEL – AREA D: Revise grille G-3 size at northwest corner of Vocal G125
from “36/18” to “42/16”.
ITEM NO. 15 SHEET M1.4 – HVAC PLAN, SECOND LEVEL – AREA D
A. Keyed note 1 of Keyed Notes, HVAC: Delete “33/M5.1” and substitute “33/M4.1”.
B. Note A of General Notes, HVAC: Delete “GENERAL”.
C. Note L of General Notes, HVAC: Delete “34/M5.1” and substitute “34/M4.1”.
ITEM NO. 16 SHEET M1.5 – HVAC PLAN, SECOND LEVEL – AREA E
A. Keyed note 1 of Keyed Notes, HVAC: Delete “33/M5.1” and substitute “33/M4.1”.
B. Note A of General Notes, HVAC: Delete “GENERAL”.
C. Note L of General Notes, HVAC: Delete “34/M5.1” and substitute “34/M4.1”.
ADDM. NO. MPC-1-5
D. HVAC PLAN, SECOND LEVEL – AREA E: At exhaust fan detail indicator located within Science
E216, delete “31/M5.1” and substitute “31/M4.1”.
ITEM NO. 17 SHEET M1.6 – HVAC PLAN, SECOND LEVEL – AREA G
A. Keyed note 1 of Keyed Notes, HVAC: Delete “33/M5.1” and substitute “33/M4.1”.
B. Note A of General Notes, HVAC: Delete “GENERAL”.
C. Note L of General Notes, HVAC: Delete “34/M5.1” and substitute “34/M4.1”.
D. HVAC PLAN, SECOND LEVEL – AREA G: Revise grille G-3 size at northwest corner of Vocal G125
from “36/18” to “42/16”.
ITEM NO. 18 SHEET M1.7 – HVAC PLAN, MECHANICAL PENTHOUSE – AREA D
A. Keyed note 1 of Keyed Notes, HVAC: Delete “33/M5.1” and substitute “33/M4.1”.
B. Note A of General Notes, HVAC: Delete “GENERAL”.
C. Note L of General Notes, HVAC: Delete “34/M5.1” and substitute “34/M4.1”.
ITEM NO. 19 SHEET M2.1 – HVAC PIPING PLAN, FIRST LEVEL – AREA D
A. Note A of General Notes, HVAC Piping: Delete “GENERAL”.
B. Note I of General Notes, HVAC Piping: Insert “MECHANICAL” between “COMPLETE” and “WORK”.
C. HVAC PIPING PLAN, FIRST LEVEL – AREA D:
1. At HP-D102 in MECH D103: Delete “14/M5.1” and substitute “14/M4.1”; Delete “15/M5.2” and substitute
“15/M4.1”; Delete “32/M5.2” and substitute “32/M4.1”.
2. At HP-D108 in ELEC D109: Delete detail indicator “43/M5.1”.
ITEM NO. 20 SHEET M2.2 – HVAC PIPING PLAN, FIRST LEVEL – AREA E
A. Note A of General Notes, HVAC Piping: Delete “GENERAL”.
B. Note I of General Notes, HVAC Piping: Insert “MECHANICAL” between “COMPLETE” and “WORK”.
ITEM NO. 21 SHEET M2.3 – HVAC PIPING PLAN, FIRST LEVEL – AREA G
A. Note A of General Notes, HVAC Piping: Delete “GENERAL”.
B. Note I of General Notes, HVAC Piping: Insert “MECHANICAL” between “COMPLETE” and “WORK”.
C. HVAC PIPING PLAN, FIRST LEVEL – AREA G:
1. At HP-G101 in MECH G111: Delete “14/M5.1” and substitute “14/M4.1”; Delete “15/M5.2” and substitute
“15/M4.1”; Delete “32/M5.2” and substitute “32/M4.1”.
2. At ERV-G1 in MECH G111: Delete “54/M5.1” and substitute “24/M4.2”.
3. MECH G111 at west side of room south of ERV-G1: Delete “43/M5.1” and substitute “43/M4.1”.
ITEM NO. 22 SHEET M2.4 – HVAC PIPING PLAN, SECOND LEVEL – AREA D
A. Note A of General Notes, HVAC Piping: Delete “GENERAL”.
ADDM. NO. MPC-1-6
B. Note I of General Notes, HVAC Piping: Insert “MECHANICAL” between “COMPLETE” and “WORK”.
ITEM NO. 23 SHEET M2.5 – HVAC PIPING PLAN, SECOND LEVEL – AREA E
A. Note A of General Notes, HVAC Piping: Delete “GENERAL”.
B. Note I of General Notes, HVAC Piping: Insert “MECHANICAL” between “COMPLETE” and “WORK”.
ITEM NO. 24 SHEET M2.7 – HVAC PIPING PLAN, MECHANICAL PENTHOUSE – AREA D
A. Note A of General Notes, HVAC Piping: Delete “GENERAL”.
B. Note I of General Notes, HVAC Piping: Insert “MECHANICAL” between “COMPLETE” and “WORK”.
C. HVAC PIPING PLAN, MECHANICAL PENTHOUSE – AREA D:
1. At ERV-D1 in MECH D300: Delete “54/M5.1” and substitute “21/M4.2”.
2. At ERV-D2 in MECH D300: Delete “54/M5.1” and substitute “22/M4.2”.
3. MECH G111 at southwest corner of room: Delete “43/M5.1” and substitute “43/M4.1”.
ITEM NO. 25 SHEET E2.1 – POWER PLAN, FIRST LEVEL – AREA D
A. Legend Notes: Keyed Notes, Power: Add keyed note “28” to read “POSITION RECEPTACLE
DIRECTLY ABOVE GOGGLE CABINET.”
B. Science D116: Add keyed note “28” in reference to the receptacle shown near the goggle cabinet.
ITEM NO. 26 SHEET E2.2 – POWER PLAN, FIRST LEVEL – AREA E
A. Legend Notes: Keyed Notes, Power: Add keyed note “28” to read “POSITION RECEPTACLE
DIRECTLY ABOVE GOGGLE CABINET.”
B. Science E116: Add keyed note “28” in reference to the receptacle shown near the goggle cabinet.
ITEM NO. 27 SHEET E2.3 – POWER PLAN, FIRST LEVEL – AREA G
A. North Exterior: Move the disconnect switches adjacent to Dust Collector DC-G101 and After-Filter AFG101.
B. Courtyard: Add “GFI/WP” subscripts to all exterior receptacles.
ITEM NO. 28 SHEET E2.4 – POWER PLAN, SECOND LEVEL – AREA D
A. Legend Notes: Keyed Notes, Power: Add keyed note “28” to read “POSITION RECEPTACLE
DIRECTLY ABOVE GOGGLE CABINET.”
B. Science D216: Add keyed note “28” in reference to the receptacle shown near the goggle cabinet.
ITEM NO. 29 SHEET E2.5 – POWER PLAN, SECOND LEVEL – AREA E
A. Legend Notes: Keyed Notes, Power: Add keyed note “28” to read “POSITION RECEPTACLE
DIRECTLY ABOVE GOGGLE CABINET.”
B. Science E216: Add keyed note “28” in reference to the receptacle shown near the goggle cabinet.
ADDM. NO. MPC-1-7
ITEM NO. 30 SHEET E3.1 – SPECIAL SYSTEMS PLANS, FIRST LEVEL, AREA D
A. KEYED NOTES, SPECIAL SYSTEMS
1. Keyed Note 21, delete note in its entirety and substitute:
"PROVIDE WIRING FOR CLASSROOM A/V SYSTEM IN THIS ROOM. SEE DETAILS FOR
REQUIREMENTS. REFER TO D104 FOR EQUIPMENT LAYOUT NOTES."
2. Keyed Note 23, delete note in its entirety and substitute:
"VIDEO PROJECTOR AND MOUNT BY OWNER CENTERED ON PROJECTION SURFACE.
LOCATE 12-14 FEET FROM PROJECTION SURFACE. COORDINATE DEVICE LOCATION
WITH ACTUAL EQUIPMENT SUPPLIED. MOUNT ADJACENT TO RECEPTACLE AND
OTHER ASSOCIATED CEILING MOUNTED DEVICES."
ITEM NO. 31 SHEET E3.2 – SPECIAL SYSTEMS PLANS, FIRST LEVEL, AREA E
A. KEYED NOTES, SPECIAL SYSTEMS
1. Keyed Note 21, delete note in its entirety and substitute:
"PROVIDE WIRING FOR CLASSROOM A/V SYSTEM IN THIS ROOM. SEE DETAILS FOR
REQUIREMENTS. REFER TO D104 FOR EQUIPMENT LAYOUT NOTES."
2. Keyed Note 23, delete note in its entirety and substitute:
"VIDEO PROJECTOR AND MOUNT BY OWNER CENTERED ON PROJECTION SURFACE.
LOCATE 12-14 FEET FROM PROJECTION SURFACE. COORDINATE DEVICE LOCATION
WITH ACTUAL EQUIPMENT SUPPLIED. MOUNT ADJACENT TO RECEPTACLE AND
OTHER ASSOCIATED CEILING MOUNTED DEVICES."
ITEM NO. 32 SHEET E3.3 – SPECIAL SYSTEMS PLANS, FIRST LEVEL, AREA G
A. KEYED NOTES, SPECIAL SYSTEMS
1. Keyed Note 21, delete note in its entirety and substitute:
"PROVIDE WIRING FOR CLASSROOM A/V SYSTEM IN THIS ROOM. SEE DETAILS FOR
REQUIREMENTS. REFER TO D104 FOR EQUIPMENT LAYOUT NOTES."
2. Keyed Note 23, delete note in its entirety and substitute:
"VIDEO PROJECTOR AND MOUNT BY OWNER CENTERED ON PROJECTION SURFACE.
LOCATE 12-14 FEET FROM PROJECTION SURFACE. COORDINATE DEVICE LOCATION
WITH ACTUAL EQUIPMENT SUPPLIED. MOUNT ADJACENT TO RECEPTACLE AND
OTHER ASSOCIATED CEILING MOUNTED DEVICES."
ADDM. NO. MPC-1-8
ITEM NO. 33 SHEET E3.4 – SPECIAL SYSTEMS PLANS, SECOND LEVEL, AREA D
A. KEYED NOTES, SPECIAL SYSTEMS
1. Keyed Note 21, delete note in its entirety and substitute:
"PROVIDE WIRING FOR CLASSROOM A/V SYSTEM IN THIS ROOM. SEE DETAILS FOR
REQUIREMENTS. REFER TO D104 FOR EQUIPMENT LAYOUT NOTES."
2. Keyed Note 23, delete note in its entirety and substitute:
"VIDEO PROJECTOR AND MOUNT BY OWNER CENTERED ON PROJECTION SURFACE.
LOCATE 12-14 FEET FROM PROJECTION SURFACE. COORDINATE DEVICE LOCATION
WITH ACTUAL EQUIPMENT SUPPLIED. MOUNT ADJACENT TO RECEPTACLE AND
OTHER ASSOCIATED CEILING MOUNTED DEVICES."
ITEM NO. 34 SHEET E3.5 – SPECIAL SYSTEMS PLANS, SECOND LEVEL, AREA E
A. KEYED NOTES, SPECIAL SYSTEMS
1. Keyed Note 21, delete note in its entirety and substitute:
"PROVIDE WIRING FOR CLASSROOM A/V SYSTEM IN THIS ROOM. SEE DETAILS FOR
REQUIREMENTS. REFER TO D104 FOR EQUIPMENT LAYOUT NOTES."
2. Keyed Note 23, delete note in its entirety and substitute:
"VIDEO PROJECTOR AND MOUNT BY OWNER CENTERED ON PROJECTION SURFACE.
LOCATE 12-14 FEET FROM PROJECTION SURFACE. COORDINATE DEVICE LOCATION
WITH ACTUAL EQUIPMENT SUPPLIED. MOUNT ADJACENT TO RECEPTACLE AND
OTHER ASSOCIATED CEILING MOUNTED DEVICES."
ITEM NO. 35 SHEET E3.6 – SPECIAL SYSTEMS PLANS, PENTHOUSE AND EXISTING AREAS A & B
A. KEYED NOTES, SPECIAL SYSTEMS
1. Keyed Note 21, delete note in its entirety and substitute:
"PROVIDE WIRING FOR CLASSROOM A/V SYSTEM IN THIS ROOM. SEE DETAILS FOR
REQUIREMENTS. REFER TO D104 FOR EQUIPMENT LAYOUT NOTES."
2. Keyed Note 23, delete note in its entirety and substitute:
"VIDEO PROJECTOR AND MOUNT BY OWNER CENTERED ON PROJECTION SURFACE.
LOCATE 12-14 FEET FROM PROJECTION SURFACE. COORDINATE DEVICE LOCATION
WITH ACTUAL EQUIPMENT SUPPLIED. MOUNT ADJACENT TO RECEPTACLE AND
OTHER ASSOCIATED CEILING MOUNTED DEVICES."
ADDM. NO. MPC-1-9
ITEM NO. 36 SHEET E3.7 – SPECIAL SYSTEMS PLANS, SECOND LEVEL, EXISTING AREA C
A. KEYED NOTES, SPECIAL SYSTEMS
1. Keyed Note 21, delete note in its entirety and substitute:
"PROVIDE WIRING FOR CLASSROOM A/V SYSTEM IN THIS ROOM. SEE DETAILS FOR
REQUIREMENTS. REFER TO D104 FOR EQUIPMENT LAYOUT NOTES."
2. Keyed Note 23, delete note in its entirety and substitute:
"VIDEO PROJECTOR AND MOUNT BY OWNER CENTERED ON PROJECTION SURFACE.
LOCATE 12-14 FEET FROM PROJECTION SURFACE. COORDINATE DEVICE LOCATION
WITH ACTUAL EQUIPMENT SUPPLIED. MOUNT ADJACENT TO RECEPTACLE AND
OTHER ASSOCIATED CEILING MOUNTED DEVICES."
ITEM NO. 37 SHEET E5.1 – ELECTRICAL SCHEDULES
A. Lighting Fixture Schedule – Interior
1. Fixture Types X1, X2, and X4: Change the manufacturer “PRESCOLITE” to “DUAL-LITE”.
B. Lighting Fixture Schedule – Interior
1. Fixture Types EHF1/X and EHF2/X: Add “HUBBELL” as an approved manufacturer.
ITEM NO. 38
SHEET E6.1 – ELECTRICAL DETAILS
A. Woods Shop EPO Control Diagram 5/E6.1: Delete the main circuit breaker (MCB) that is shown in
branch-circuit Panel H18. (This panel is MLO.)
ITEM NO. 39 SHEET E6.4 – ELECTRICAL DETAILS
A. At detail 6, add note "PROJECTOR AND MOUNT BY OWNER"
END OF ADDENDUM NO. MPC-1
ADDM. NO. MPC-1-10
SOUTHVIEW MIDDLE SCHOOL – PHASE 2
ANKENY, IOWA
11-12102-00
BID SET
SECTION 274100 – CLASSROOM AUDIO-VISUAL SYSTEMS
PART 1 - GENERAL
1.1
RELATED DOCUMENTS
A.
1.2
Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
SUMMARY
A.
1.3
This Section includes cabling for owner provided audio-visual equipment. Provide installation
of cabling, termination and testing.
DEFINITIONS AND ABBREVIATIONS
A.
Abbreviations:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
1.4
NICET: National Institute for Certification in Engineering Technologies.
IDC: Insulation Displacement Connector.
PVC: Polyvinyl chloride.
USB: Universal Serial Bus.
UTP: Unshielded twisted pair.
RGBHV: Red, Green, Blue, Horizontal Sync, Vertical Sync.
BNC: Bayonet Neill-Concelman.
RCA: Radio Corporation of America.
DIN: Deutsches Institut fur Normung.
MAAP: Mini Architectural Adapter Plate.
RMS: Root Mean Square.
THD: Total Harmonic Distortion.
CTS-I: Certified Technology Specialist – Installation.
QUALITY ASSURANCE
A.
Source Limitations:
contractor.
1.
Cabling for audio-visual equipment shall be installed by the data
Experience: Installer shall have a minimum of five (5) years of commercial Audio-Visual
installation experience and have successfully completed with references at least 5
projects of similar size and scope.
CLASSROOM AUDIO-VISUAL SYSTEMS
ATTACHMENT E1 TO ADDENDUM MPC-1
274100 - 1
SOUTHVIEW MIDDLE SCHOOL – PHASE 2
ANKENY, IOWA
1.5
11-12102-00
BID SET
SUBMITTALS
A.
Product Data: For each product or component specified, include data on features, ratings, and
performance.
B.
Manuals: Collect manuals and electronic media from furnished equipment, organize and
deliver to Owner.
PART 2 - PRODUCTS
2.1
CLASSROOM AUDIO-VISUAL SYSTEM
A.
2.2
Provide cabling to owner provided equipment in quantities required for each classroom and
other locations as shown on drawings and as specified.
TEACHERS WORKSTATION CONNECTIONS
A.
Provide cabling between the projector mounted equipment and the teacher’s workstation
equipment.
B.
Computer Video Cabling
1.
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
a.
2.
Impact Acoustics, Rapid Run Product.
Description: Manufactured, preterminated “PC” runner cable with intermediate
connectors and flying leads with HD15 and 3.5mm stereo audio connectors. Cable system
supports high resolution VGA communication with VESA standard EDID
communications, passing ID Bit information between the display and the workstation
computer. The PC runner cable provides EDID communications ONLY when used with
the correct connections.
a.
Due to the quantity of options available, the following “RapidRun” part numbers
from “Cablestogo.com” are provided for clarity ONLY. The length of the runner
cables will vary by location, contractor to verify lengths. All cables are CMP rated.
Cabling with flying leads at projector and at Teacher’s Workstation.
1)
2)
3)
4)
C.
Plenum Analog PC Runner (50ft): Product number 40752.
Flying lead (3ft at Projector): Product number 42106.
Flying lead (1.5ft at Teacher’s Workstation): Product number 40853.
Stereo 1.5ft audio extension at projector: Product number 40405.
Video and Audio Cabling
1.
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
CLASSROOM AUDIO-VISUAL SYSTEMS
ATTACHMENT E1 TO ADDENDUM MPC-1
274100 - 2
SOUTHVIEW MIDDLE SCHOOL – PHASE 2
ANKENY, IOWA
a.
b.
c.
2.
Belden CDT Inc.; Electronics Division.
CommScope, Inc.
West Penn Wire.
Description: Cabling for composite video and stereo audio to connect DVD/VHS/Tuner
source equipment to projector equipment. Plenum rated RG-59 coaxial cable with RCA
connectors for video and two (2) stranded, shielded audio cables.
a.
Video (Plenum Rated): NFPA 70, Type CMP for Composite video signals.
1)
2)
3)
4)
5)
b.
RG-59/U.
No. 20 AWG, stranded, bare copper conductor; foam fluorinated ethylene
propylene insulation.
Shield shall be 95 percent braided bare copper.
FEP – Fluorinated Ethylene Propylene jacket.
Connector: RCA crimp style, color yellow.
Stereo Audio (Plenum Rated): NFPA 70, Type CMP.
1)
2)
3)
D.
11-12102-00
BID SET
No. 22 AWG, 7x30 stranded, bare copper conductors; polymer alloy
insulation.
95 percent braided copper shield and 100 percent foil shield.
Connector: RCA male solder style, color red and white.
Coaxial Cabling
1.
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
a.
b.
c.
d.
2.
Commscope
Digicon.
Holland Electronics.
Other approved manufacturer.
Coaxial-Cable Connectors: Type F, 75 ohms.
a.
b.
c.
d.
e.
f.
g.
Compression style with complete 360 degree conical crimp approved by the cable
manufacturer for use on cable specified.
Brass body with tin plating meeting SCTE IPS-SP-401 standards.
Return Loss to be greater than 30dB from 5-1000Mhz.
Cable holding force minimum 50 lbs.
Insertion loss less than .3dB to 1000Mhz.
Shielding effectiveness greater than 70dB to 1000Mhz.
Hex or pinch type crimp connectors will not accepted.
CLASSROOM AUDIO-VISUAL SYSTEMS
ATTACHMENT E1 TO ADDENDUM MPC-1
274100 - 3
SOUTHVIEW MIDDLE SCHOOL – PHASE 2
ANKENY, IOWA
E.
HDMI Cabling
1.
F.
Provide HDMI cabling with pass through connectors at each end.
Equipment Connection Cables
1.
2.
Provide cables between the cart and the wall outlet to allow the cart to be moved 6 feet
away from the wall.
Description: Provide equipment connection cables for all equipment shown on drawings:
a.
b.
c.
d.
e.
f.
g.
2.3
11-12102-00
BID SET
Category 6 certified, 3ft patch cable for connecting projector to building LAN.
VGA cables to connect teacher’s computer to document camera and document
camera to teacher workstation outlet. Lengths appropriate for room layout.
Audio cable to connect teacher workstation to teacher workstation outlet. Cable to
be strapped with VGA cables.
Composite video and stereo audio cables to connect DVD/VHS/TUNER to teacher
workstation outlet.
Coaxial cable with threaded F-type connector for broadband CATV connection to
tuner input.
HDMI cable and audio cabling for connection to PC.
Provide UL listed power outlet strips for each teacher’s workstation. Mount outlet
strip concealed in cart. Outlet strip shall be designed to accommodate direct plug
transformers. Power cord length shall be sufficient to reach the floor plus 6 ft for
movement.
ACCESSORIES AND SUPPORTS
A.
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
1.
B.
Arlington Industries.
Description: Plenum-rated, flexible cable loops, with capacity to hold 2 inch diameter cable
bundle minimum.
1.
Provide Arlington Industries model TL20.
PART 3 - EXECUTION
3.1
COORDINATION
A.
Coordinate work of this Section with related work of other contractors as necessary to obtain
proper installation of items.
CLASSROOM AUDIO-VISUAL SYSTEMS
ATTACHMENT E1 TO ADDENDUM MPC-1
274100 - 4
SOUTHVIEW MIDDLE SCHOOL – PHASE 2
ANKENY, IOWA
3.2
11-12102-00
BID SET
WIRING METHODS
A.
Wiring Method: Install cables in raceways except in accessible ceiling spaces where
unenclosed wiring method may be used.
1.
2.
3.
3.3
Install plenum cable in environmental air spaces, including plenum ceilings.
Install all cabling within raceways in areas with exposed structure.
Install cabling within raceway in walls and other structures.
IDENTIFICATION PRODUCTS
A.
Comply with the following:
1.
3.4
Cable Labels: Self-adhesive vinyl or vinyl-cloth wraparound tape markers, machine
printed self-laminating tape with alphanumeric cable designations applied to each end of
each cable.
CLEANING
A.
3.5
Prior to final acceptance, clean system components and protect from damage and deterioration.
INSTALLATION
A.
Install wiring in Cable Supports (J-Hooks or Loops) from raceway stub-up to projector in areas
with accessible ceiling. Wiring run above concealed accessible ceilings shall be plenum rated
and secured with appropriate fasteners.
B.
Route cables to teacher’s workstation multi-media outlet and terminate. Install supports to
building structure. Install pass-thru modules in multi-media outlet and connect.
END OF SECTION 274100
CLASSROOM AUDIO-VISUAL SYSTEMS
ATTACHMENT E1 TO ADDENDUM MPC-1
274100 - 5
Related documents
Download