Singapore Slovakia Slovenia South Africa South Korea Spain Sweden Switzerland Syria Taiwan Thailand Turkey UAE Ukraine United Kingdom Uruguay USA Venezuela Vietnam Yemen Weidmuller is the leading manufacturer of components for electrical connection technology to transmit energy, signals and data. The Weidmuller product portfolio ranges from terminal blocks, PCB connectors and terminals, protected ­components, Industrial Ethernet components, I/O components and relay sockets to power supplies and overvoltage protection ­modules suitable for all applications. Assemble Services, marking solutions with a variety of tools and software systems, round off the range. As an OEM supplier, the company sets global standards in the field of electrical connection technology. 11 Catalog Iran Ireland Israel Italy Japan Jordan Kazakhstan Kuwait Latvia Lebanon Lithuania Luxembourg Macedonia Malaysia Malta Mexico Montenegro Netherlands New Zealand Norway Oman Paraguay Peru Philippines Poland Portugal Qatar Romania Russia Saudi Arabia Serbia 11 Power Delivery and Protection Solutions Argentina Australia Austria Azerbaijan Bahrain Belarus Belgium BosniaHerzegovina Brazil Bulgaria Canada Chile China Colombia Costa Rica Croatia Czech Republic Denmark Ecuador Egypt Estonia Finland France Germany Greece Hong Kong Hungary Iceland India Indonesia CATALOG www.weidmuller.com Power Delivery and Protection Solutions Catalog Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email:info1@weidmuller.ca Website:www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email:clientes@weidmuller.com.mx Website:www.weidmuller.com.mx Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email:info@weidmuller.com Website:www.weidmuller.com 010/11 • XM • LIT0803 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Contents Page Power Distribution Blocks —WPDB Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Product Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Fuse Terminal Blocks —WSI Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Product Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Power Delivery Products Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 INSTAPOWER—Single Phase Input Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 PRO-M—Single Phase Input Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 PRO-M—Three Phase Input Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Diode Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 PRO-H Series—Single Phase Input Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 PRO-H Series—Diode Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 connectPower—Single Phase Input Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 connectPower—Three Phase Input Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 connectPower—Diode Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 connectPower DC-DC Converters Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 Product Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 connectPower Battery Back Up Unit for DC Power Management Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 Product Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Electronic Circuit Protection Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Product Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 Branch Rated Circuit Protection Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 9926 Series—AC Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 9926 Series—AC Version with Auxiliary and Alarm Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 9926 Series—DC Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 Supplemental Circuit Protection 9926 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 9926 Series with Auxiliary and Alarm Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 9926 Series—Ground Fault Current Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 9926 Series—Mounting Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 CB4200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 CB2200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 CB9100 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Overvoltage Protection — MCZ Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 Product Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 Surge Protection — MTL Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 SD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77 SLP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 MA15 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 TP48 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 DIN-Rail Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87 1 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com We i d m u l l e r C a t a l o g s a t a G l a n c e Catalog 1: Modular Terminal Blocks Catalog 6: Tools • Z-Series (Tension clamp) • P-Series (Push-in) • W-Series (Screw clamp) • I-Series (IDC) • Stud Style (Screw clamp) • Power Distribution Blocks and Fuse Blocks • Cutting • Stripping • Crimping • Screwdrivers Catalog 2: PCB Terminals and Connectors Catalog 7: Marking Systems • Space Saving Technologies • Wide Variety of Clamping Technologies • Pitches Ranging from 3.50 mm to 15.00 mm • Orientations Ranging from 90˚ to 270˚ • Terminal Markers • Wire and Cable Markers • Device and Equipment Markers • Printing Systems and Software Catalog 3: RockStar®– Heavy Duty Connectors Catalog 8: Sensor Actuator Interface • Inserts • Modular System • Housings IP65 and IP69K • Cable Glands • SAI Passive Blocks • SAI Universal • SAI ASI • Cables and Connectors Catalog 4.1: Analog Signal Conditioning Catalog 9: Industrial Ethernet • Intrinsically Safe Conditioners • Signal Converters and Monitoring Devices • Indicators and Configurable Displays • Fieldbus Distribution Boxes • Unmanaged Switches • Managed Switches • Routers • Media Converters Catalog 4.2: Relays and Optocouplers Catalog 10: Connectivity Solutions Catalog • Mechanical Relays • Solid-State (opto) Relays • Power Solid-State Relays • Multifunction Relays and Timers • Short Form Catalog • Product Overview Catalog 4.4: Surge Protection Catalog 11: Power Delivery and Protection Solutions • Surge Protection for Low-Voltage • Surge Protection for Instrumentation and Control • Surge Protection for Data Interfaces • Surge Protection for Photovoltaic Systems • Cutting • Power Supplies • DC/DC Converters • Automatic Machines • Ferrules ® • JACKPAC IP67 ® • SteadyTEC • IE Connectors • Accessories • Battery Back-up Units • Diodes and Overvoltage • Protection Catalog 4.5: Interface Units and PLC Solutions Catalog 12: Wireless Connectivity Solutions • Interface Units • PLC Interfaces – H-, R and S-System • Byte Precabling Solution • Wireless Ethernet • Wireless Gateways • Wireless Transceivers • Antennas and Accessories Catalog 5: Enclosures and Cable Glands CD ROM • Pdf files of All Master Catalogs, Brochures, Datasheets • Enclosures • Cable Glands • Cabtite (Cable Entry System) 2 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — P o w e r D i s t r i b u t i o n B l o c k s Power Distribution Blocks WPDB Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller’s Power Distribution blocks. By using the best materials and the best technology, Wedimuller provides the safest and most innovative connections available in a wide area of industrial applications, including; machinery, material handling, building/installation and power conditioning. These DIN-rail mountable blocks combine installed cost savings over traditional methods, high short-circuit protection, and application flexibility. Weidmuller’s Power Distribution Blocks deliver power and performance – without compromising safety requirements. • Space-saving design • For use with a wide range of wire sizes • SCCR rated* (UL 508-A, 100kA) • IEC finger-safe design • IP20 class protection • For DIN-rail or direct mounting * when used with fuses 508A 100kA 3 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Power Distribution Blocks WPDB 70 1-1 WPDB 70 1-1 AL Type WPDB 70 1-1 WPDB 70 1-1 AL WPDB 70/35 1-4 WPDB 70/35 1-4 AL Part No. 1879470000 1879460000 Type WPDB 70/35 1-4 WPDB 70/35 1-4 AL WPDB 185 1-1 WPDB 185 1-1 AL Part No. 1879360000 1879480000 Type WPDB 185 1-1 WPDB 185 1-1 AL Part No. 1879410000 1879400000 Technical Data Housing material PA 66/6 Flammability class UL 94 V0 Conductor WPDB 70 1-1: Copper (75°C Cu wire only) WPDB 70 1-1 AL: Aluminum (90°C Cu/Al wire) Contact material WPDB 70 1-1: Copper WPDB 70 1-1 AL: Aluminum Contact plating Zinc Technical Data Housing material PA 66/6 Flammability class UL 94 V0 Conductor WPDB 70/35 1-4: Copper (75°C Cu wire only) WPDB 70/35 1-4 AL: Aluminum (90°C Cu/Al wire) Contact material WPDB 70/35 1-4: Copper WPDB 70/35 1-4 AL: Aluminum Contact plating Zinc Technical Data Housing material PA 66/6 Flammability class UL 94 V0 Conductor WPDB 185 1-1: Copper (75°C Cu wire only) WPDB 185 1-1 AL: Aluminum (90°C Cu/Al wire) Contact material WPDB 185 1-1: Copper WPDB 185 1-1 AL: Aluminum Contact plating Zinc Current Rating UL/CSA* Current Rating UL/CSA* Current Rating UL/CSA* 175 A at 600 V 175 A at 600 V Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 2/0…#14 70…2.5 1 Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 2/0…#14 70…2.5 1 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 2/0…#14 70…2.5 1 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles #2…#14 35…2.5 4 Operating Specifications Maximum temperature Operating range Storage temperature 100°C -10°C…+60°C -25°C…+60°C Operating Specifications Maximum temperature Operating range Storage temperature 100°C -10°C…+60°C -25°C…+60°C 335 A at 600 V Line Wire , kcmil/AWG Wire gauge, mm2 Number of poles 400…#6 185…16 1 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 400…#6 185…16 1 Operating Specifications Maximum temperature Operating range Storage temperature 100°C -10°C…+60°C -25°C…+60°C Accessories SK WSD-S 9008850000 (1.5-10 mm 9 piece set, Allen head screwdrivers) SST WPDB 1879490000 (Accessory pin for fixing multi-pole block assemblies) WEW 35/3 1879390000 (Pair of end brackets) VK WPDB 1 1879370000 (Cap for spare 2/0 line connections) VK WPDB 2 1879380000 (Cap for spare 350 kcmil line connections) Accessories SK WSD-S 9008850000 (1.5-10 mm 9 piece set, Allen head screwdrivers) SST WPDB 1879490000 (Accessory pin for fixing multi-pole block assemblies) WEW 35/3 1879390000 (Pair of end brackets) VK WPDB 1 1879370000 (Cap for spare 2/0 line connections) VK WPDB 2 1879380000 (Cap for spare 350 kcmil line connections) Accessories SK WSD-S 9008850000 (1.5-10 mm 9 piece set, Allen head screwdrivers) SST WPDB 1879490000 (Accessory pin for fixing multi-pole block assemblies) WEW 35/3 1879390000 (Pair of end brackets) VK WPDB 1 1879370000 (Cap for spare 2/0 line connections) VK WPDB 2 1879380000 (Cap for spare 350 kcmil line connections) Marking Tags KSW Strips, blank** Marking Tags KSW Strips, blank** Marking Tags KSW Strips, blank** 1629970000 *Based on NEC table 310-16 for 75°C copper wire **Pre-printed strips standard with product. Custom strips also available. 1629970000 *Based on NEC table 310-16 for 75°C copper wire **Pre-printed strips standard with product. Custom strips also available. *Based on NEC table 310-16 for 75°C copper wire **Pre-printed strips standard with product. Custom strips also available. 4 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 1629970000 www.barr-thorp.com Power Distribution Blocks WPDB 185/35 1-8 WPDB 185/35 1-8 AL Type WPDB 185/35 1-8 WPDB 185/35 1-8 AL WPDB 300 2-2 WPDB 300 2-2 AL Part No. 1879430000 1879420000 Type WPDB 300 2-2 WPDB 300 2-2 AL WPDB 16/6 3/4 Part No. 1879450000 1879440000 Type WPDB 16/6 3/4 Technical Data Housing material PA 66/6 Flammability class UL 94 V0 Conductor WPDB 185/35 1-8: Copper (75°C Cu wire only) WPDB 185/35 1-8 AL: Aluminum (90°C Cu/Al wire) Contact material WPDB 185/35 1-8: Copper WPDB 185/35 1-8 AL: Aluminum Contact plating Zinc Technical Data Housing material PA 66/6 Flammability class UL 94 V0 Conductor WPDB 300 2-2: Copper (75°C Cu wire only) WPDB 300 2-2 AL: Aluminum (90°C Cu/Al wire) Contact material WPDB 300 2-2: Copper WPDB 300 2-2 AL: Aluminum Contact plating Zinc Technical Data Housing material Flammability class Conductor Current Rating UL/CSA* Current Rating UL/CSA* Current Rating UL 310 A at 600 V 840 A at 600 V Part No. 1939440000 Wemid UL 94 V0 Copper (75ºC Cu wire only) Contact material Copper Contact plating 80 A at 600 V Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 350…#6 / 2/0…#14 185…16 / 70…2.5 1 Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 600…#4 300…25 2 Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 14…6 2.5…16 1 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles #2…#14 35…2.5 8 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 600…#4 300…25 2 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles (2) 14…6/(4) x14…10 (2) 2.5...16/(4) 2.5…6 6 Operating Specifications Maximum temperature Operating range Storage temperature 100°C -10°C…+60°C -25°C…+60°C Operating Specifications Maximum temperature Operating range Storage temperature 100°C -10°C…+60°C -25°C…+60°C Operating Specifications Maximum temperature Operating range Storage temperature Accessories SK WSD-S 9008850000 (1.5-10 mm 9 piece set, Allen head screwdrivers) SST WPDB 1879490000 (Accessory pin for fixing multi-pole block assemblies) WEW 35/3 1879390000 (Pair of end brackets) VK WPDB 1 1879370000 (Cap for spare 2/0 line connections) VK WPDB 2 1879380000 (Cap for spare 350 kcmil line connections) Accessories SK WSD-S 9008850000 (1.5-10 mm 9 piece set, Allen head screwdrivers) SST WPDB 1879490000 (Accessory pin for fixing multi-pole block assemblies) WEW 35/3 1879390000 (Pair of end brackets) VK WPDB 2 1879380000 (Cap for spare 350 kcmil line connections) VK WPDB 3 1880060000 (Cap for spare 600 kcmil line connections) Accessories SDK PZ1 (crosshead screwdriver, Pozidriv type) SDK PZ2 (crosshead screwdriver, Pozidriv type) SK-S 2.0-8.0 (7-piece hexagon wrench set) Marking Tags KSW Strips, blank** Marking Tags KSW Strips, blank** Marking Tags LogiMark Strips, blank 1629970000 *Based on NEC table 310-16 for 75°C copper wire **Pre-printed strips standard with product. Custom strips also available. 1629970000 120º C 9008530000 9008540000 9008860000 1882890000 *Based on NEC table 310-16 for 75°C copper wire **Pre-printed strips standard with product. Custom strips also available. 5 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Power Distribution Blocks WPDB 35-16/16 1-16 WPDB 70/16 1/10 Type WPDB 35-16/16 1-16 Technical Data Housing material Flammability class Conductor WPDB 120/35-16-10 1/2-5-4 Part No. 1939450000 Type WPDB 70/16 1/10 Part No. 1939460000 Wemid UL 94 V0 Copper (75ºC Cu wire only) Technical Data Housing material Flammability class Conductor Wemid UL 94 V0 Copper (75ºC Cu wire only) Contact material Copper Contact plating Contact material Copper Contact plating Current Rating UL 115 A at 600 V Current Rating UL Type WPDB 120/35-16-10 1/2-5-4 Technical Data Housing material Flammability class Conductor Part No. 1939470000 Wemid UL 94 V0 Copper (75ºC Cu wire only) Contact material Copper Contact plating 115 A at 600V Current Rating UL/CSA 230 A at 600V Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles (1) 8…2/(1) 10…6 (1) 10…35/(1) 6…16 2 Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 6…0 16…70 1 Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 14…6 2.5…16 6 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 14…6 2.5…16 10 Load Wire gauge, kcmil/AWG (2) 14…2/(5) 14…6/(4) 14…8 Wire gauge, mm2 (2) 2.5…35/(5) 2.5…16/(4) 2.5…10 Number of poles 11 Operating Specifications Maximum temperature Operating range Storage temperature 120º C Accessories SDK PZ2 (crosshead screwdriver, Pozidriv type) SK-S 2.0-8.0 (7-piece hexagon wrench set) Marking Tags LogiMark Strips, blank 9008540000 Operating Specifications Maximum temperature Operating range Storage temperature Accessories SK-S 2.0-8.0 (7-piece hexagon wrench set) 120º C 9008860000 9008860000 1882890000 Marking Tags LogiMark Strips, blank 1882890000 Operating Specifications Maximum temperature Operating range Storage temperature Accessories SD 1.0x5.5x150 (crosshead screwdriver, Pozidriv type) SD 0.8x4.5x125 (crosshead screwdriver, Pozidriv type) SK-S 2.0-8.0 (7-piece hexagon wrench set) Marking Tags LogiMark Strips, blank 6 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 2…4/0 35…120 1 120º C 9008350000 9009020000 9008860000 1882890000 Power Distribution Blocks WPDB 185/35-16-10 1/2-5-4 Type WPDB 185/35-16-10 1/2-5-4 Technical Data Housing material Flammability class Conductor WPDB 3 x 70/16 1/6 Part No. 1939480000 Wemid UL 94 V0 Copper (75ºC Cu wire only) Contact material Copper Type WPDB 3 x 70/16 1/6 Technical Data Housing material Flammability class Conductor Contact material WPDB 35/16/6/N 1/2/5/11 Part No. 1939490000 Wemid UL 94 V0 Copper (75ºC Cu wire only) Copper Contact plating Contact plating Current Rating UL/CSA 310 A at 600V Current Rating UL Type WPDB 35/16/6/N 1/2/5/11 Technical Data Housing material Flammability class Conductor 115 A at 600V Current Rating UL 6…0 16…70 3x1 Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles Load Wire gauge, kcmil/AWG (2) 14…2/(5) 14…6/(4) 16…8 Wire gauge, mm2 (2) 2.5…35/(5) 2.5…16/(4) 1.5…10 Number of poles 11 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 14…6 2.5…16 3x6 Load Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles Operating Specifications Maximum temperature Operating range Storage temperature Operating Specifications Maximum temperature Operating range Storage temperature Accessories SDK PZ1 (crosshead screwdriver, Pozidriv type) SDK PZ2 (crosshead screwdriver, Pozidriv type) SK-S 2.0-8.0 (7-piece hexagon wrench set) Marking Tags LogiMark Strips, blank 9008530000 Accessories SK-S 2.0-8.0 (7-piece hexagon wrench set) Copper Contact plating Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles 120º C Wemid UL 94 V0 Copper (75ºC Cu wire only) Contact material 3/0…350 95…185 1 Line Wire gauge, kcmil/AWG Wire gauge, mm2 Number of poles Part No. 1939510000 120º C 9008860000 9008540000 335 A at 600V (3x1) 10…2/(3x5) 16…10/(3x2) 11…4 (3x1) 6…35/(3x5) 1.5…6/(3x2) 4…16 (3x1)/(3x5)/(3x2) (1) 10…2/(4) 16…10/(6) 11…4 (1) 6…35/(4) 1.5…6/(6) 4…16 11 Operating Specifications Maximum temperature Operating range Storage temperature Accessories SDK PZ1 (crosshead screwdriver, Pozidriv type) SDK PZ2 (crosshead screwdriver, Pozidriv type) 120º C 9008530000 9008540000 9008860000 1882890000 Marking Tags LogiMark Strips, blank 1882890000 Marking Tags LogiMark Strips, blank 1882890000 7 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Power Distribution Blocks Tightening Torque Table With recommended strip back lengths to maintain IP20 rating Part No. Wire Strip Hex Product Wire Hole Back Driver Description Range Length Size 1879460000 WPDB 70 1-1 AL 2/0…#14 AWG 0.75 in 1879470000 WPDB 70 1-1 (70…2.5 mm2) (19.1 mm) 2/0…#14 AWG 1 in (70…2.5 mm2) (25.4 mm) 5 mm 5 mm Wire Product Size* Torque** 2/0…#1 AWG 100 lbs-in (70…50 mm2) (11.4 N-m) #2…#6 AWG 80 lbs-in Part No. 1939440000 Description Wire Strip Pozidriv Back Screwdriver Size Wire Size Length 6…14 AWG .47….35 in WPDB (16…2.5 mm2) (12…9 mm) 16/6 3/4 10…14 AWG .71….47 in (35…16 mm2) (9 N-m) (6…2.5 mm2) (18…12 mm) #8…#14 AWG 35 lbs-in 6…14 AWG .71….47 in (10…2.5 mm2) (3.9 N-m) 2/0…#1 AWG 100 lbs-in (70…50 mm2) (11.4 N-m) #2…#6 AWG 80 lbs-in 1939450000 (16…2.5 mm2) (18…12 mm) WPDB 6…10 AWG .47….39 in 35-16/16 1-16 (16…6 mm2) (12…10 mm) 2…8 AWG .59….55 in (35…16 mm2) (9 N-m) (35…10 mm2) (15…14 mm) 1879480000 WPDB 70/35 1-4 AL #8…#14 AWG 35 lbs-in 6…14 AWG .71….47 in 1879360000 WPDB 70/35 1-4 (10…2.5 mm2) (3.9 N-m) WPDB (16…2.5 mm2) (18…12 mm) #2…#6 AWG 80 lbs-in 70/16 1/10 0…6 AWG .63….59 in (35…16 mm2) (9 N-m) (70…16) (16…15 mm) #8…#14 AWG 35 lbs-in 4/0…2 AWG 1.41…1.06 in #2…#14 AWG 0.625 in (35…2.5 mm2) (15.9 mm) 350…#6 AWG 1.125 in (35…2.5 mm2) (28.5 mm) 4 mm 8 mm 1879420000 WPDB 185/35 1-8 AL 1879430000 WPDB 185/35 1-8 2/0…#14 AWG 0.875 in (70…2.5 mm2) (22.2 mm) #2…#14 AWG 0.875 in (35…2.5 mm2) (22.2 mm) 1879400000 WPDB 185 1-1 AL 400…#6 AWG 1.3 in 1879410000 WPDB 185 1-1 (185…16 mm2) (33 mm) 1879440000 WPDB 300 2-2 AL 600…#4 AWG 1.3 in 1879450000 WPDB 300 2-2 (300…25 mm2) (33 mm) 5 mm 4 mm 10 mm 10 mm 1939460000 (10…2.5 mm2) (3.9 N-m) (120…35 mm2) (29…27 mm) 350 kcmil…3/0 AWG 200 lbs-in 8…14 AWG .47….39 in (185…95 mm2) (22.6 N-m) WPDB (10…2.5 mm2) (12…10 mm) 2/0…#1 AWG 100 lbs-in 120/35-16-10 1/2-5-4 6…14 AWG .47….39 in (70…50 mm2) (11.4 N-m) (16…2.5 mm2) (12…10 mm) #2…#6 AWG 80 lbs-in 2…14 AWG .47….39 in 1939470000 (35…16 mm2) (9 N-m) (35…2.5 mm2) (12…10 mm) 2/0…#1 AWG 100 lbs-in 3/0…350 AWG 1.41…1.06 in (70…50 mm2) (11.4 N-m) (185…95 mm2) (29…27 mm) #2…#6 AWG 80 lbs-in 8…16 AWG .47….39 in WPDB (10…1.5 mm2) (12…10 mm) 185/35-16-10 1/2-5-4 6…14 AWG .47….39 in (35…16 mm2) (9 N-m) #8…#14 AWG 35 lbs-in 1939480000 (10…2.5 mm2) (3.9 N-m) (16…2.5 mm2) (12…10 mm) #2…#6 AWG*** 80 lbs-in*** 2…14 AWG .47….39 in (35…16 mm2) (9 N-m) (35…2.5 mm2) (12…10 mm) #8…#14 AWG 35 lbs-in 0…4 AWG .63….59 in WPDB (70…16 mm2) (16…15 mm) 3 x 70/16 1/6 6…14 AWG .47….39 in (10…2.5 mm2) (3.9 N-m) 400 kcmil…00 AWG 220 lbs-in (185…70 mm2) (24.9 N-m) (16…2.5 mm2) (12…10 mm) 0…#2 AWG 170 lbs-in 10…16 AWG .47…35 in (50…35 mm2) (19.2 N-m) #3…#6 AWG 130 lbs-in 1939490000 1939510000 (6…1.5 mm2) (12…9 mm) WPDB 4…11 AWG .71…47 in 35/16/6/N 1/2/5/11 (25…16 mm2) (14.7 N-m) (16…4 mm2) (18…12 mm) 600…500 kcmil AWG 310 lbs-in 2…10 AWG .71…47 in (35…6 mm2) (18…12 mm) (300…240 mm2) (35.1 N-m) 400 kcmil…00 AWG 220 lbs-in (185…70 mm2) (24.9 N-m) 0…#2 AWG 170 lbs-in (50…35 mm2) (19.2 N-m) #3…#4 AWG 130 lbs-in (25 mm2) (14.7 N-m) PZ1 PZ2 PZ2 M4 M4 PZ2 M5 M6 SD 0.8x4.5x125 SD 0.8x4.5x125 SD 1.0x5.5x150 M6 SD 0.8x4.5x125 SD 0.8x4.5x125 SD 1.0x5.5x150 *Wire sizes based on AWG/kcmil standards with closest commercially available mm size. **Torque values -0, +10%. ***Applies only to part number 1879420000 WPDB 185/35 1-8 AL. 8 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com M5 M3 PZ1 PZ2 PZ2 Torque 13.3…26.6 lbs-in (1.5…3 Nm) 7.1…13.3 lbs-in (0.8…1.5 Nm) 7.1…13.3 lbs-in (0.8…1.5 Nm) 31…44.3 lbs-in (3.5…5 Nm) 31…44.3 lbs-in (3.5…5 Nm) 7.1…13.3 lbs-in (0.8…1.5 Nm) 44.3 lbs-in (5 Nm) 168.2 lbs-in (19 Nm) 17.7 lbs-in (2 Nm) 17.7 lbs-in (2 Nm) 31 lbs-in (3.5 Nm) 168.2 lbs-in (19 Nm) 17.7 lbs-in (2 Nm) 17.7 lbs-in (2 Nm) 31 lbs-in (3.5 Nm) 44.3 lbs-in (5 Nm) 26.6 lbs-in (3 Nm) 7.1 lbs-in (0.8 Nm) 13.3 lbs-in (1.5 Nm) 13.3 lbs-in (1.5 Nm) Power Distribution Blocks Housing Dimensions WPDB 70 1-1 WPDB 70 1-1 AL WPDB 70/35 1-4 WPDB 70/35 1-4 AL WPDB 185 1-1 WPDB 185 1-1 AL 9 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Power Distribution Blocks Housing Dimensions WPDB 185/35 1-8 WPDB 185/35 1-8 AL WPDB 300 2-2 WPDB 300 2-2 AL 10 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Power Distribution Blocks Housing Dimensions WPDB 120/35-16-10 1/2-5-4 ▲ ▲ 4.2 WPDB 16/6 3/4 ▲ 86 % 1 3 2 54 4 5 6 7 8 9 10 11 ▲ 29.9 4.2 WPDB 35-16/16 1-16 WPDB 185/35-16-10 1/2-5-4 86 % 61.5 1 3 2 4 5 6 7 8 9 10 11 ▲ 22.8 ▲ 22.8 ▲ WPDB 70/16 1/10 ▲ 29.9 WPDB 3 x 70/16 1/6 29.9 ▲ 60.5 60.6 ▲ ▲ ▲ 52.5 17.5 11 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Power Distribution Blocks Housing Dimensions 60 ▲ ▲ WPDB 35/16/6/N 1/2/5/11 ▲ 62 N N N L2 L1 N L3 70.5 ▲ ▲ ▲ ▲ ▲ 5.3 Mounting Instructions DIN Rail Mounting Panel Mounting 12 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Power Distribution Blocks WPDB 120/35-16-10 1/2-5-4 and WPDB 185/35-16-10 1/2-5-4 86 mm Assembly instructions M5 30 mm 62 mm WPDB 35-16/16 1-16 6 M5 (3,5 N.m) (31 In.Lbs) PZ2 L1 WPDB 35/16/6/N 1/2/5/11 N (2 N.m) (17.5 In.Lbs) L2 N 4 L3 N N WPDB 3x70/16 1/6 5 3 13 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — F u s e Te r m i n a l B l o c k s 508A 200kA WSI 25CC WSI 4, 5 x 20 mm WSI 25 10x38 WSI 4/2, 1 1/4" x 1/4" WSI 25CC/LED Fuse terminal 5 x 20 mm and 1 1/4" x 1/4" with screw connection technology (clamping yoke) WSI 25 10x38/LED Weidmuller offers DIN rail mounted terminal blocks for the popular 10.3 mm x 38 mm (13/32” x 1.5”) midget fuses. Compact and touch safe, these terminals meet CSA, UL and IEC requirements. Features: • CSA certified for 600 Vac, 30 A max. • UL rated 600 Vac, 30 A max. The new WSI 4 and 4/2 fuse terminal series offers you a compact solution for implementing short-circuit and overload protection utilizing 5 x 20 mm and 1 1/4" x 1/4" fuses. Features: • Standard screw clamp technology to accommodate maximum 10 AWG conductors • Blown fuse indication by means of LED voltage ranges (10 - 250 V) • 1, 2, 3 pole with or without indicator • Combi-foot for mounting on TS 32 and TS 35 DIN-rails (WSI 4/2 only) • Mounting on 35 mm DIN rail • Special interlocking of levers for multiple phase disconnection • Only 17.8 mm wide per pole • Large marking area to accommodate standard WS and DEK markers • Lever mechanism for quick and safe fuse replacement • Vented housing to reduce internal heating and extend fuse life • 3 W power dissipation maximum • Two versions are available: - WSI 25 10x38 accepts all types of 13/32" x 1.5" midget fuses including CC type. - WSI 25CC ONLY accepts CC type fuses which have a typical interrupting capacity of 200kA and in compliance to UL508A standard. • Both version are available with or without LED 14 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com F u s e Te r m i n a l B l o c k s 25 mm2 WSI 25 10x38 For fuses 10x38 width x length x height with TS 35 x 7.5 mm max. current / max. cond. cross-section A/mm2 max. clamping range mm2 Technical data Rated data Rated voltage, adjacent terminal Rated current Rated cross-section Rated isolation voltage Power loss 1 pole / 2 pole / 3 pole UL94 Flammability class Approvals Allowable power dissipation for standard version fuse Allowable power dissipation for semi-conductor protection version fuse Interrupting Capacity Clamped conductors (H05V/H07V) Solid / stranded Flexible / Flexible with wire end ferrule Tightening torque range (clamping screw) Stripping length V A mm2 V 17.8 x 58 x 81 32 / 25 1.5 ... 25 25 mm2 WSI 25 CC For fuses CC 17.8 x 58 x 81 32 / 25 1.5 ... 25 IEC 60947-7-3 IEC UL CSA 690 600 600 32 30 30 25 AWG 18 ... 4 AWG 18 ... 4 800 0.3 / 0.6 / 0.9 V-0 EN 60079-7 ar IEC 60947-7-3 IEC UL CSA 690 600 600 32 30 30 25 AWG 18 ... 4 AWG 18 ... 4 800 0.3 / 0.6 / 0.9 V-0 EN 60079-7 ar 3W 4.3W (10mm2, 25A) 200kA mm2 mm2 Nm mm Rated connection 1.5 ... 16 / 1.5 ... 16 0.75 … 25 / 0.75 … 25 2.0 ... 2.4 11 Rated connection 1.5 ... 16 / 1.5 ... 16 0.75 … 25 / 0.75 … 25 2.0 ... 2.4 11 Ordering data Version 1 pole without LED 2 pole without LED 3 pole without LED 1 pole with LED 2 pole with LED 3 pole with LED Type WSI 25/1 WSI 25/2 WSI 25/3 WSI 25/1 WSI 25/2 WSI 25/3 10x38 10x38 10x38 10x38/LED 10x38/LED 10x38/LED Qty. 12 6 4 12 6 4 Part No. 1966020000 1966090000 1966080000 1966060000 7940029427 7940029428 LED: 110-600Vac/dc, 2mA leakage Note Type WSI 25/1 WSI 25/2 WSI 25/3 WSI 25/1 WSI 25/2 WSI 25/3 CC CC CC CC/LED CC/LED CC/LED Qty. 12 6 4 12 6 4 Part No. 1966050000 1966040000 1966030000 1966070000 7940029425 7940029426 Qty. 200 10 10 1 Part No. 1880100000 1044440000 1044450000 1044460000 LED: 110-600Vac/dc, 2mA leakage Accessories Marking Systems 2 pole ganging kit 3 pole ganging kit Single phase bus bar (insulated) Type ESG 6/15 K MC WHITE SET 2 POLE WSI 25 SET 3 POLE WSI 25 WQB 18MM/90 1METER Qty. 200 10 10 1 Part No. 1880100000 1044440000 1044450000 1044460000 Type ESG 6/15 K MC WHITE SET 2 POLE WSI 25 SET 3 POLE WSI 25 WQB 18MM/90 1METER Dimensions 15 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com F u s e Te r m i n a l B l o c k s 4 mm2 WSI 4 Fuse terminal 5 x 20 mm Width/Length/Height with TS35x7.5 mm Width/Length/Height with TS32x15 mm Max. current / max. cond. cross-section A/mm2 Max. clamping range mm2 Technical data Rated data Rated voltage / to adjoining terminal V Rated current / to adjoining terminal A Rated cross-section mm2 Rated impulse voltage / Pollution severity kV/Plug gauge IEC 60-947-1 / flammability class acc. UL94 Approvals Clampable conductors (H05V/H07V) Solid / stranded Flexible / flexible w. wire end ferrule Tightening torque range (clamping screw) Stripping length / blade size mm2 mm2 Nm mm / - 2 clampable conductors of equal cross-section Solid / stranded Flexible / flexible w. wire end ferrule mm2 mm2 Fuse terminal 1 1/4" x 1/4" 9.1 x 81.6 x 54 9.1 x 81.6 x 58.5 15 / 6 0.05 ... 6 8 x 50.7 x 39.4 15 / 4 0.05 ... 4 IEC 60947-7-3 / VDE 0100-537 IEC UL CSA 500 300 300 12 15 15 4 AWG 22…12 AWG 22…12 6 / 3 A3 / V-0 r 4 mm2 WSI 4/2 EN 60079-7 IEC 60947-7-3 / VDE 0100-537 IEC UL CSA 500 300 300 15 15 15 4 AWG 30…10 AWG 30…10 6 / 3 A3 / V-0 { r EN 50019 { Rated connection 0.5…4 / 0.5…4 0.5…4 / 0.5…4 0.5…0.6 (M 3) 8 / 0.6 x 3.5 Rated connection 0.2…6 0.2…4 0.5…0.6 (M 3) 10 / 0.6 x 3.5 0.5…1.5 0.5…1.5 / 0.5…1.5 0.34…2.5 0.34…2.5 / 0.34…1.5 Ordering Data Version black Wemid without LED 10 - 36 V 30 - 70 V 60 - 150 V 140 - 250 V Type WSI 4 WSI 4/LD WSI 4/LD WSI 4/LD WSI 4/LD 10 - 36 V AC/DC 30 - 70 V AC/DC 60 - 150 V AC/DC 140 - 250 V AC/DC Part No. 1886580000 1886590000 1886560000 1886570000 1886550000 Type WSI 4/2 WSI 4/2/LD WSI 4/2/LD WSI 4/2/LD WSI 4/2/LD Part No. Type GZ 0.5A/F GZ 1.0A/F GZ 2.0A GZ 3.0A GZ 5.0A GZ 7.0A GZ 10.0A GZ 12.5A/FF Dummy fuse Type 10 - 36 V AC/DC 30 - 70 V AC/DC 60 - 150 V AC/DC 140 - 250 V AC/DC Part No. 1880430000 1880410000 1880440000 1880420000 1880390000 Accessories Fuse cartridges 1 1/4" x 1/4" without indicator 33 kA breaking capacity (F) = fast Nominal voltage (V) 440 V Fuse cartridges 5 x 20 mm (IEC 60127-2) Rated voltage 250 V 0.25 Rated breakage capacity 1500 A 0.5 (at 250V / 50Hz / cos j = 0.7) 1 2 External jumper comb A A A A Type E 0.5 E1 E2 E3 E5 E7 E 10 E 12.5 Current [A] A A A A A A A A quick-blow quick-blow quick-blow quick-blow Insulated Type Current G 20/0.25A/F G 20/0.5A/F G 20/1A/F G 20/2A/F Type Current QB/WSI 4, 2-pole (8 mm) QB/WSI 4, 3-pole (8 mm) QB/WSI 4, 4-pole (8 mm) [A] [A] 15 15 15 Part No. 0430500000 0430600000 0430700000 0430900000 Part No. 0461100000 0461200000 0461300000 Type Current [A] QB/WSI 4/2, 10-pole (9 mm) 30 End plate / partition black Wemid Not Required Current [A] 0.5 1 2 3 5 7 10 12.5 15 Current [A] WAP WSI 4/2 Width [mm] 2.5 Part No. 0533800000 0525500000 0294500000 0295700000 0294600000 0295800000 0293900000 0245400000 1582770000 Part No. Part No. 67603346 1880450000 End bracket dark beige EW35 0383560000 (TS 35) EW35 EWK 1 0383560000 (TS 35) 0206160000 (TS32) Screwdriver Standard version SD 0.6X3.5X100 9008330000 SD 0.6X3.5X100 9008330000 WS 12/6.5 MC DEK 5/6 MC 1609920000 1609820000 WS 12/6.5 MC DEK 5/6 MC 1609920000 1609820000 Marking systems Tags 16 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — P o w e r D e l i v e r y P ro d u c t s Weidmuller offers a full range of power supplies for process control and manufacturing automation applications. INSTAPOWER The INSTAPOWER family of power supplies is designed in compact and robust housings for quick and easy TS35 DIN-rail mounting. • Output voltage adjustable via potentiometer • Wide-range input: 85…264 VAC /120…300 VDC (24 W) / 110…370 VDC (25/48W) • LED status indicator (25/48 W) • Option for connecting in parallel • International approvals for use world-wide PRO-M Series Weidmuller’s new compact PRO-M Series Switchmode Power Supplies are optimized for machinery and offer a host of advantages. • • • • • Slim housings for space saving installation in the cabinet DIN-rail mountable without any gap (no clearance necessary) Operating temperature range of -25°C to +70°C Autoselect Input for wide input range without any switch; for DC and AC voltages Power boost of 120% enables inductive and capacitive loads; additional starting capacity with up to a 2-minute boost • Parallel connections allow simple power increase for up to five units without diode module • MTBF > 500,000 Hours T-SERIES The T-SERIES is a new generation of high performance DIN-rail mounted single-phase power supplies designed to work reliably even under demanding factory floor conditions. • Autoselect input eliminates the possibility of selecting the wrong input type • Hazardous approvals - designed for use in process automation and other harsh industrial environments. • Operating temperature range of -25°C to +70°C • Capable of cold start-up at full load at -25°C. • Indefinite short circuit, overvoltage and overtemperature protection • Remote On/Off • Shock and vibration proof • Variable output voltage automatically adjusts and overcomes voltage drops/dips • Easy installation with detachable screw terminal block and snap-on DIN-rail mounting • DC-OK signal and external shut down function connectPower The connectPower Series power supplies are available in both single phase and three phase, and offer a number of features designed for demanding applications. • Fulfill the demand for high quality power delivery solutions • Designed with packaging advantages that include a rugged housing, ability to panel mount, pluggable connectors and load sharing capability • Feature up to 200% of maximum rated output for a specified amount of time (power boost) • Available with low residual ripple (< 10mV in some cases) • Most models have universal AC/DC input • Longer hold-up time for most models • Feature greater galvanic isolation between input and output • Operate over a broader range of ambient temperatures • Many available in 5, 12, 24, 28, and 48V versions 17 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I N S TA P O W E R — S i n g l e P h a s e I n p u t S u p p l i e s CP SNT 12W 0.5A CP SNT 24W Approvals: r ® LISTED % Diagram/Schematic Circuit Diagram – secondary through plug-in jumpers ZQV cross-connectable to other WAVE-modules Ordering Data Type CP SNT 12W 0.5A 24 VDC / 0.5 A Output voltage/maximum current Technical Data Input voltage Minimum Typical Maximum at 115 VAC at 230 VAC at 125 VDC at 250 VDC Input current (Average values for reference only) Input protection Fuse Inrush current Overvoltage protection Switching frequency Efficiency at maximum load Maximum ripple Regulation Load (10-100% load) at input voltage Overload protection Maximum capacitance at output Hold time (Maximum output current following input loss) Temperature Humidity Galvanic isolation at 115 VAC at 230 VAC Storage Operating Operating temperature Storage temperature Input-output Input/output to mounting rail Input to ground Output to ground Wire size Dimensions (L x W x H) Weight Mounting position Clearance Part No. 9918840024 Type CP SNT 24 VDC 28 VDC 15 VDC Part No. 24W /1A /1A / 1.5 A 9928890024 9928890028 9928890015 12 VDC / 1.5 A 5 VDC / 2 A 9928890012 9928890005 85 VAC, 120 VDC 115-230 VAC ± 10%, 50/60 Hz 85 VAC, 120 VDC 115-230 VAC ± 10%, 50/60 Hz 265 VAC, 300 VDC 260 mA RMS ± 20% 180 mA RMS ± 20% 125 mA ± 20% 65 mA ± 20% 265 480 270 280 140 2 A slow fuse (internal, not user serviceable) Thermistor 2 A slow fuse (internal, not user serviceable) Thermistor Varistor Varistor 100 kHz PWM 80% 100 kHz PWM 78% 0.1% RMS Vp-p 0.2% 0.3% RMS Vp-p 2% (12, 15 and 5 V) 0.5% (24 and 28 V) 0.2% 85 VAC - 265 VAC In Overcurrent shutdown with automatic restart plus thermal shutdown/short circuit 0.2% Overcurrent shutdown with automatic restart plus thermal shutdown/short circuit 8000 μF 30 ms 80 ms 8000 μF 35 ms 160 ms -40°C…+85°C (-40°F…+185°F) -20°C…+50°C (-4°F…+122°F) full rated load Derating: 33% at 60°C (140°F) 20…85% RH non-condensing -40°C…+85°C (-40°F…+185°F) -20°C…+50°C (-4°F…+122°F) full rated load Derating: 33% at 60°C (140°F) 20…85% RH non-condensing 20…90% RH 3 kV RMS 20…90% RH 3 kV RMS 4 kV RMS 1.5 kV RMS 4 kV RMS 1.5 kV RMS 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 90 x 18 x 112.5 mm (3.54 x 0.71 x 4.43 in.) 140 g (0.311 lbs.) Horizontal on mounting rail TS35 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 90.5 x 52 x 62.5 mm (3.56 x 2.05 x 2.46 in.) 160 g (0.35 lbs.) Horizontal on mounting rail TS35 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) CSA, UL 508 Listed, CE CSA, UL 508 Listed, CE VAC, 300 VDC mA RMS ± 20% mA RMS ± 20% mA ± 20% mA ± 20% Approvals/Certifications CSA Class 1 Div. 2 and Zone 2 for 9928890012 and 9928890024 UL 1310 (Class 2) for 9928890024 18 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I N S TA P O W E R — S i n g l e P h a s e I n p u t S u p p l i e s CP SNT 25W 5A CP SNT 48W Approvals: r % ® LISTED Diagram/Schematic Circuit Diagram Ordering Data Derating Curves Derating Curves Diagram/Schematic Circuit Diagram Diagram/Schematic Circuit Diagram Type CP SNT 25W 5V 5A 4…8 VDC (adjustable via potentiometer) / 5 A Output voltage/maximum current Part No. 8754960000 Type 46…55 VDC (adjustabe via potentiometer)/1A Technical Data Input voltage Minimum Typical 85 VAC, 110 VDC 115/230 VAC 85 VAC, 110 VDC 115/230 VAC Maximum at 115 VAC 264 VAC, 370 VDC 950 mA 264 VAC, 370 VDC 950 mA at 230 VAC at 125 VDC at 250 VDC 500 mA 500 mA Fuse 2.5A (T) / 250V Varistor Fuse 2.5A (T) /250V Varistor Switching frequency limited 100 kHz PWM limited 100 kHz PWM Efficiency at maximum load Maximum ripple 78% 120 mVp-p 78% 120 mVp-p 1% 0.2% 105%…150% max. rated output power, 1% 0.2% 105%…150% max. rated output power, automatic restart >70% 35 ms >50 ms -40°C…+85°C (-40°F…+185°F) -20°C…+50°C (-4°F…+122°F) full rated load Derating: 33% at 60°C (140°F) automatic restart >75% / >78% / >80% 35 ms >50 ms -40°C…+85°C (-40°F…+185°F) -20°C…+50°C (-4°F…+122°F) full rated load Derating: 33% at 60°C (140°F) 20…85% RH non-condensing 20…90% RH 20…85% RH non-condensing 20…90% RH 3 kV RMS 4 kV RMS 3 kV RMS 4 kV RMS 1.5 kV RMS 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 62.5 x 70 x 90.5 mm (2.46 x 2.76 x 3.56 in.) Ca. 2 kg Horizontal on mounting rail TS35 >30 mm above and below 1.5 kV RMS 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 62.5 x 70 x 90.5 mm (2.46 x 2.76 x 3.56 in.) Ca. 2 kg Horizontal on mounting rail TS35 >30 mm above and below Input current (Average values for reference only) Input protection Fuse Inrush current Overvoltage protection Regulation Load (10-100% load) at input voltage Overload protection Maximum capacitance at output Hold time (Maximum output current following input loss) Temperature Humidity Galvanic isolation at 115 VAC at 230 VAC Storage Operating Operating temperature Storage temperature Input-output Input/output to mounting rail Input to ground Output to ground Wire size Dimensions (L x W x H) Weight Mounting position Clearance Approvals/Certifications CSA / CE / UL 508 / cURus 60950 / GS UL 1310 (Class 2) Part No. CP SNT 48W 9…15 VDC (adjustable via potentiometer)/4A 8754970000 15…28 VDC (adjustable via potentiometer)/2A 8739140000 8879230000 CSA / CE / UL 508 / cURus 60950 / GS UL 1310 (Class 2) 19 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW PRO-M—Single Phase Input Supplies CP M SNT 70W 24V 3A CP M SNT 120W 24V 5A Derating Curve Temperature De-Rating % of Nominal Current 120% 100% 80% 60% 40% 20% 0% -10% 0% 10% 20% 30% 40% 50% 60% 70% Ambient Temperature (°C) Ordering Data Type CP M SNT 70W 24V 3A Technical Data Input Specifications Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal)/Inrush current Circuit Protection Part No. 8951330000 Type CP M SNT 120W 24V 5A Part No. 8951340000 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 80...370 V DC 0.80 A @ 230 V AC / 1.5A @ 115 V AC 0.25 A @ 370 V DC / 1.1 A @ 80 V DC 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 80...370 V DC 1.3 A @ 230 V AC / 2.4 A @ 115 V AC 0.5 A @ 370 V DC / 1.8 A @ 80 V DC yes/max. 20 A 2 A / DI, safety fuse 6 A, Char. B, Circuit breaker 2...4 A, Char. C, Circuit breaker yes/max. 30 A 4 A / DI, safety fuse 6 A, Char. B, Circuit breaker 3...5 A, Char. C, Circuit breaker 24 V DC ± 1 % 24 V DC ± 1 % 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 3 A @ 55 °C 3.6 A @ 45 °C 3.3 A @ 50 °C 1.8 A @ 70 °C 3.6 A for 1 min, ED=5 % 5 A @ 55 °C 6.0 A @ 45 °C 5.5 A @ 50 °C 3.1 A @ 70 °C 6 A for 1 min, ED=5 % 88 % @ 230 V AC / > 85 % @ 115 V AC > 0.5 @ 230 V AC / > 0.53 @ 115 V AC 89 % @ 230 V AC / > 85 % @ 115 V AC > 0.5 @ 230 V AC / > 0.53 @ 115 V AC > 100 ms @ 230 V AC / > 20 ms @ 100 V AC yes 125 x 33 x 130 0.69 kg > 100 ms @ 230 V AC / > 20 ms @ 100 V AC yes 125 x 40 x 130 0.8 kg CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 Input Screw connection 3 for L/N/PE 0.5 / 6 Output Screw Connection 4 (++/--) 0.5 / 6 Input Screw connection 3 for L/N/PE 0.5 / 6 Output Screw Connection 5 (++/---) 0.5 / 6 0.5 / 2.5 26 / 12 0.5 / 2,.5 26 / 12 0.5 / 2.5 26 / 12 0.5 / 2.5 26 / 26 Output Specifications Rated output voltage Output voltage Residual ripple, switching peaks Rated output current @ Vrated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C General Specifications Efficiency Power factor (approx.) Mains buffering @ Irated Parallel connection option Length x Width x Height Weight mm Approvals/Certifications Connection Data Type of connection Number of terminals Conductor cross-section, rigid min/max Conductor cross-section, flexible min/max Conductor cross-section, AWG/kcmil min/max mm² mm² Accessories * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! 20 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW PRO-M—Single Phase Input Supplies CP M SNT 180W 24V 7.5A CP M SNT 250W 24V 10A Derating Curve Temperature De-Rating % of Nominal Current 120% 100% 80% 60% 40% 20% 0% 0% 10% 20% 30% 40% 50% 60% 65% 70% Ambient Temperature (°C) Ordering Data Type CP M SNT 180W 24V 7.5A Technical Data Input Specifications Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal)/Inrush current Circuit Protection Part No. 8951350000 Type CP M SNT 250W 24V 10A Part No. 8951360000 100...240 V AC (wide-range input) 85...264 V AC 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 80...370 V DC 1.9 A @ 230 V AC / 3.6 A @ 115 V AC 0.6 A @ 370 V DC / 2.6 A @ 80 V DC yes 6 A / DI, safety fuse 16 A, Char. B, Circuit breaker 47...63 Hz 80...370 V DC 1.3 A @ 230 V AC / 2.5 A @ 115 V AC 0.9 A @ 370 V DC / 3.4 A @ 80 V DC yes 6 A / DI, safety fuse 16 A, Char. B, Circuit breaker 5...10 A, Char. C, Circuit breaker 5...10 A, Char. C, Circuit breaker 24 V DC ± 1 % 24 V DC ± 1 % 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 7.5 A @ 60 °C 9.0 A @ 45 °C 8.2 A @ 55 °C 5.6 A @ 70 °C 9 A for 1 min, ED=5 % 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 10 A @ 60 °C 12 A @ 45 °C 11 A @ 55 °C 7.5 A @ 70 °C 12 A for 1 min, ED=5 % 90 % @ 230 V AC / > 85 % @ 115 V AC > 0.5 @ 230 V AC / > 0.53 @ 115 V AC > 40 ms @ 230 V AC / > 20 ms @ 100 V AC yes 150 x 50 x 130 1.0 kg 90 % @ 230 V AC / > 85 % @ 115 V AC > 0.98 @ 230 V AC / > 0.98 @ 115 V AC > 40 ms @ 230 V AC / > 20 ms @ 100 V AC yes 150 x 60 x 130 1.2 kg CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 Input Screw connection 3 for L/N/PE 0.5 / 6 Output Screw Connection 5 (++/---) 0.5 / 6 Input Screw connection 3 for L/N/PE 0.5 / 6 Output Screw Connection 5 (++/---) 0.5 / 6 0.5 / 2.5 26 / 12 0.5 / 2.5 26 / 12 0.5 / 2.5 26 / 12 0.5 / 2.5 26 / 12 Output Specifications Rated output voltage Output voltage Residual ripple, switching peaks Rated output current @ Vrated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C General Specifications Efficiency Power factor (approx.) Mains buffering @ Irated Parallel connection option Length x Width x Height Weight mm Approvals/Certifications Connection Data Type of connection Number of terminals Conductor cross-section, rigid min/max Conductor cross-section, flexible min/max Conductor cross-section, AWG/kcmil min/max mm² mm² Accessories * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! 21 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW PRO-M—Single Phase Input Supplies CP M SNT 500W 24V 20A CP M SNT 1000W 24V 40A Derating Curve Temperature De-Rating % of Nominal Current 120% 100% 80% 60% 40% 20% 0% 0% 10% 20% 30% 40% 50% 60% 65% 70% Ambient Temperature (°C) Ordering Data Type CP M SNT 500W 24V 20A Technical Data Input Specifications Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal)/Inrush current Circuit Protection Part No. 8951370000 Type CP M SNT 1000W 24V 40A Part No. 8951380000 100...240 V AC wide-range input) 85...264 V AC 47...63 Hz 80...370 V DC 2.5 A @ 230 V AC / 4.9 A @ 115 V AC 1.6 A @ 370 V DC / 6.8 A @ 80 V DC 100...240 V AC (wide-range input) 85...264 V AC 47...63 Hz 80...370 V DC 4.9 A @ 230 V AC / 9.6 A @ 115 V AC 3.0 A @ 370 V DC / 13.5 A @ 80 V DC yes 10 A / DI, safety fuse 20 A, Char. B, Circuit breaker 10...12 A, Char. C, Circuit breaker yes 16 A / DI, safety fuse 25 A, Char. B, Circuit breaker 14...16 A, Char. C, Circuit breaker 24 V DC ± 1 % 24 V DC ± 1 % 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 20 24 22 15 24 40 48 44 30 48 Output Specifications Rated output voltage Output voltage Residual ripple, switching peaks Rated output current @ Vrated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C General Specifications Efficiency Power factor (approx.) Mains buffering @ Irated Parallel connection option Length x Width x Height Weight mm A A A A A @ 60 °C @ 45 °C @ 55 °C @ 70 °C for 1 min, ED=5 % A A A A A @ 60 °C @ 45 °C @ 55 °C @ 70 °C for 1 min, ED=5 % > 90 % @ 230 V AC / > 85 % @ 115 V AC > 0.98 @ 230 V AC / > 0.98 @ 115 V AC > 90 % @ 230 V AC / > 85 % @ 115 V AC > 0.98 @ 230 V AC / > 0.98 @ 115 V AC > 40 ms @ 230 V AC / > 20 ms @ 100 V AC yes 150 x 121 x 130 1.5 kg > 40 ms @ 230 V AC / > 20 ms @ 100 V AC yes 150 x 180 x 130 1.5 kg CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 Input Screw connection 3 for L/N/PE 0.5 / 6 Output Screw Connection 5 (++/---) 0.5 / 6 Input Screw connection 3 for L/N/PE 0.5 / 6 Output Screw Connection 5 (++/---) 0.5 / 16 0.5 / 2.5 26 / 10 0.5 / 2.5 26 / 10 0.5 / 2.5 26 / 10 2.5 / 10 26 / 6 Approvals/Certifications Connection Data Type of connection Number of terminals Conductor cross-section, rigid min/max Conductor cross-section, flexible min/max Conductor cross-section, AWG/kcmil min/max mm² mm² Accessories * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! 22 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW P R O - M — T h re e P h a s e I n p u t S u p p l i e s CP M SNT3 120W 24V 5A CP M SNT3 250W 24V 10A Derating Curve Temperature De-Rating % of Nominal Current 120% 100% 80% 60% 40% 20% 0% 0% 10% 20% 30% 40% 50% 60% 65% 70% Ambient Temperature (°C) Ordering Data Type CP M SNT3 120W 24V 5A Technical Data Input Specifications Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) Circuit Protection Output Specifications Rated output voltage Output voltage Residual ripple, switching peaks Rated output current @ Vrated Continuous output current @ 24 V DC Part No. 8951390000 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.5 A @ 3 x 500 V AC / 0.6 A @ 3 x 400 V AC 0.4 A @ 800 V DC / 0.7 A @ 450 V DC no 2 A / DI, safety fuse 1...2 A, Char. C, Circuit breaker no 2 A / DI, safety fuse 2...3 A, Char. C, Circuit breaker 24 V DC ± 1 % 22.5…29.5 V DC (adjustable via potentiometer on front) 24 V DC ± 1 % 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 5 A @ 60 °C 6.0 A @ 45 °C 5.5 A @ 55 °C 100 mVss @ 24 V DC,IN 10 A @ 60 °C 12 A @ 45 °C 11 A @ 55 °C 7.5 A @ 70 °C 12 A for 1 min, ED=5 % 3.7 A @ 70 °C 6 A for 1 min, ED=5 % General Specifications Efficiency Power factor (approx.) Mains buffering @ Irated 90 % @ 3 x 500 V AC / > 90 % @ 3 x 400 V AC > 0.75 @ 3 x 500 V AC / > 0.78 @ 3 x 400 V AC > 25 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC mm Weight Part No. 8951400000 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.25 A @ 3 x 500 V AC / 0.3 A @ 3 x 400 V AC 0.2 A @ 800 V DC / 0.4 A @ 450 V DC Power boost @ 24 V DC, 60 °C Parallel connection option Length x Width x Height Type CP M SNT3 250W 24V 10A yes 125 x 40 x 130 0.55 kg 90 % @ 3 x 500 V AC / > 90 % @ 3 x 400 V AC > 0.75 @ 3 x 500 V AC / > 0.78 @ 3 x 400 V AC > 25 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes 150 x 60 x 130 0.9 kg CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 Input Screw connection 4 for L1/L2/L3/PE 0.5 / 6 0.5 / 2.5 Output Screw Connection 5 (++/---) 0.5 / 6 0.5 / 2.5 Input Screw connection 4 for L1/L2/L3/PE 0.5 / 6 0.5 / 2.5 Output Screw Connection 5 (++/---) 0.5 / 6 0.5 / 2.5 26 / 12 26 / 12 26 / 12 26 / 12 Approvals/Certifications Connection Data Type of connection Number of terminals Conductor cross-section, rigid min/max Conductor cross-section, flexible min/max Conductor cross-section, AWG/kcmil min/max mm² mm² Accessories * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! 23 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW P R O - M — T h re e P h a s e I n p u t S u p p l i e s CP M SNT3 500W 24V 20A CP M SNT3 1000W 24V 40A Derating Curve Temperature De-Rating % of Nominal Current 120% 100% 80% 60% 40% 20% 0% 0% 10% 20% 30% 40% 50% 60% 65% 70% Ambient Temperature (°C) Ordering Data Type CP M SNT3 500W 24V 20A Technical Data Input Specifications Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) Circuit Protection Part No. 8951410000 Type CP M SNT3 1000W 24V 40A Part No. 8951420000 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 0.9 A @ 3 x 500 V AC / 1.1 A @ 3 x 400 V AC 0.7 A @ 800 V DC / 1.3 A @ 450 V DC 3 x 400...3 x 500 V AC (wide-range input) 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC acc. to UL508) 1.8 A @ 3 x 500 V AC / 2.1A @ 3 x 400 V AC 1.4 A @ 800 V DC / 2.5A @ 450 V DC no 2 A / DI, safety fuse 3...5 A, Char. C, Circuit breaker no 4 A / DI, safety fuse 10 A, Char. B, Circuit breaker 6...8 A, Char. C, Circuit breaker 24 V DC ± 1 % 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 24 V DC ± 1 % 22.5…29.5 V DC (adjustable via potentiometer on front) 100 mVss @ 24 V DC, IN 20 24 22 15 24 40 48 44 30 48 Output Specifications Rated output voltage Output voltage Residual ripple, switching peaks Rated output current @ Vrated Continuous output current @ 24 V DC Power boost @ 24 V DC, 60 °C General Specifications Efficiency Power factor (approx.) Mains buffering @ Irated Parallel connection option Length x Width x Height Weight mm A A A A A @ 60 °C @ 45 °C @ 55 °C @ 70 °C for 1 min, ED=5 % A A A A A @ 60 °C @ 45 °C @ 55 °C @ 70 °C for 1 min, ED=5 % > 90 % @ 3 x 500 V AC / > 91 % @ 3 x 400 V AC > 0.75 @ 3 x 500 V AC / > 0.78 @ 3 x 400 V AC > 90 % @ 3 x 500 V AC / 92 % @ 3 x 400 V AC > 0.75 @ 3 x 500 V AC / > 0.78 @ 3 x 400 V AC > 25 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes 150 x 121 x 130 1.5 kg > 25 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes 150 x 180 x 130 2.9 kg CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 CE, cURus, cULus Listed to UL508A and CSA C22.2 No. 107.1 Input Screw connection 4 for L1/L2/L3/PE 0.5 / 6 0.5 / 2.5 26 /10 Input Screw connection 4 for L1/L2/L3/PE 0.5 / 6 0.5 / 2.5 26 / 10 Approvals/Certifications Connection Data Type of connection Number of terminals Conductor cross-section, rigid min/max Conductor cross-section, flexible min/max Conductor cross-section, AWG/kcmil min/max mm² mm² Output Screw Connection 5 (++/---) 0.5 / 6 0.5 / 2.5 26 / 10 Output Screw Connection 5 (++/---) 0.5 / 16 0.5 / 10 26 / 6 Accessories * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! * Recommendation applies only for AC operation; the max. permissible operating voltage is to be observed in all cases! 24 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — D i o d e M o d u l e s f o r R e d u n d a n c y Redundancy, Load Sharing, Increased Power Delivery Weidmuller’s diode modules are designed to enhance the ConnectPower series of DC power supplies and provide a more reliable Power Delivery Solution. They are cost effective products that enable redundancy as well as load sharing between power supplies, thus extending the useful life of the power supply. It is important to keep in mind that before paralleling power supplies, their output voltage must be calibrated to be within ±50mV of each other, and the parallel connection must be positioned as close as possible to the load. Diode modules can increase the reliability of a Power Delivery Solution by preventing current feedbacks between paralleled power supplies. 25 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — D i o d e M o d u l e s f o r R e d u n d a n c y Parallel Connection for Increased Power Delivery 24VDC/20Amp 10Amp Power Supply 10Amp Power Supply OUT +V +V -V -V 230VAC 230VAC 115VAC 115VAC 8710620000 CP DM 10 8708680000 CP SNT 250W 24V 10A Input 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A DC OK L N • The amount of power needed is provided by two power supplies combined in parallel PE 12 11 14 +V DC OK +V -V E1 -V -V -V E2 L N PE 12 11 14 +V +V -V -V IN 24VDC/10Amp 24VDC/10Amp • Diode modules provide galvanic isolation between power supplies Provide Uninterrupted DC Power with Redundancy and Fault Indication (this example supplying 7A to load) Diode Module 24VDC/7Amp 10Amp Power Supply 10Amp Power Supply • Use status relays for remote alarm indication OUT +V +V -V -V 230VAC 230VAC 115VAC 115VAC 8708680000 CP SNT 250W 24V 10A 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A DC OK L N PE 12 11 14 +V DC OK +V -V -V E1 -V -V E2 L N PE 12 11 14 +V +V -V -V IN 24VDC/3.5Amp 24VDC/3.5Amp Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus • The amount of power needed is provided by two power supplies combined in parallel Increase DC Power Delivery to Control Systems (this example supplying 14A to load) Diode Module 24VDC/14Amp 10Amp Power Supply 10Amp Power Supply OUT +V +V -V -V 230VAC 230VAC 115VAC 115VAC 8708680000 CP SNT 250W 24V 10A 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A DC OK L N • Use status relays for remote alarm indication PE 12 11 14 +V DC OK +V -V E1 -V -V -V E2 L N PE 12 11 14 +V +V -V -V IN 24VDC/7Amp 24VDC/7Amp Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus • Under normal operating conditions, the critical load is provided by both the 10A and 3A power supply Guarantee DC Power to Critical Loads (this example supplying 3A to critical load) 24VDC/3Amp 10Amp Power Supply 24VDC/10Amp Critical Loads OUT +V +V -V -V Diode Module 24VDC/10Amp 230VAC 115VAC 8708680000 CP SNT 250W 24V 10A 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A Status Relays (Change-Over Contact) e.g. to PLC, IPC or Fieldbus DC OK L N PE 12 11 14 +V +V -V E1 -V -V -V E2 • If the larger power supply fails, the critical load will continue to be maintained by the 3A power supply • This ensures uninterrupted power to the critical load IN Non-critical Loads 24VDC/10Amp Status Relays (Change-Over Contact) e.g. to PLC, IPC or Fieldbus 12 11 10 V+ V+ V- V- DC OK 8703660000 CP SNT 70A 24V 3A 24Amp Power Supply 24VDC/3Amp L N PE Note: Two power supplies in parallel must be calibrated to within ± 50 mv of each other. 26 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Diode Modules for Redundancy CP DM 10 10A per Input Diode Module CP DM 20 20A per Input Diode Module Approvals: % \ Derating Curve Schematic Schematic 3/5/10/20A Output load / ambient temperature +V 120 -V +V -V Load (%) 100 80 60 40 20 E1 0 -10 0 10 20 30 40 50 60 70 E2 -V E1 E2 -V Ambient temperature (°C) Type CP DM 10 Ordering Data Technical Data Input Input voltage Input current Output Output voltage Output current General Specifications Temperature Operating Storage Efficiency under max. load Mount onto mounting rail Mounting position Mounting Weight Dimensions (L x W x H) Type of Connection Clamping area input (nominal / min. / max.) Clamping area output (nominal / min. / max.) Indication signals Voltage Alarm Fault Relay Voltage Current Configuration Other Terminations Set point Voltage drop input-output Fan Input/output Alarm contact Qty. 1 Part No. 8710620000 Type CP DM 20 Qty. 1 Part No. 8768650000 40 VDC max. 10 A per input max. Vin - 0.5 typ. 20 A max. 40 VDC max. 20 A per input max. Vin - 0.5 typ. 40 A max. -10°C…+55°C (+14°F…+131°F) -20°C…+85°C (-4°F…+185°F) approx. 95.5% at 24 VDC -10°C…+55°C (+14°F…+131°F) -20°C…+85°C (-4°F…+185°F) approx. 95% at 24 VDC Mounting rail TS35 to DIN 50022 Horizontal Clearance: side 2 4 cm; above/below 2 10 cm Mounting rail TS35 to DIN 50022 Horizontal Clearance: side 2 4 cm; above/below 2 10 cm approx. 0.15 kg (0.33 lbs.) 125.0 x 55.5 mm x 110.0 (4.92 x 2.19 x 4.33 in.) approx. 0.5 kg (1.1 lbs.) 125.0 x 55.5 mm x 110.0 (4.92 x 2.19 x 4.33 in.) Screw 4 / 0.13 / 6 mm2 (12 / 26 / 10 AWG) 4 / 0.13 / 6 mm2 (12 / 26 / 10 AWG) None Screw 4 / 0.13 / 6 mm2 (12 / 26 / 10 AWG) 10.0 / 0.32 / 16.0 mm2 (8 / 22 / 6 AWG) None None None None None None None 0.5 V typ. None None None None None 0.5 V typ. None N/A N/A N/A N/A CE, cURus, cULus Listed to UL508 and CSA C22.2 No. 107.1 CE, cURus, cULus Listed to UL508 and CSA C22.2 No. 107.1 Approvals/Certifications 27 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW PRO-H Series—Single Phase Input Supplies CP T SNT 70W 12V 6A L (+) N(- CP T SNT 90W 24V 3.8A + AC PE CP T SNT 140W 12V 12A DC - Ordering Data Type CP T SNT 70W 12V 6A Technical Data Input Specifications Input voltage Input voltage range Input voltage frequency Harmonic limits Hold up time Inrush current Recommended Circuit breaker, Curve 1 or fuse, slow blow type Efficiency Output Specifications Output voltage Output voltage adj. range Output current Output power max. Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Status indicator Power OK signal – trigger threshold: – active output signal: (reference to –Vout) – relay output General Specifications Operating temperature range Cooling Mounting Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 Remote On/Off (See LIT0917 - Installation Instructions) Isolation Environment – Vibration acc. IEC 60068-2-6 – Shock acc. IEC 60068-2-27 Dimension (W x D x H) Clearances – Above /Below – Sides Weight Approvals Part No. 1105430000 Type CP T SNT 140W 12V 12A Part No. 1105440000 Type CP T SNT 90W 24V 3.8A Part No. 1105790000 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <12A @ 115VAC; <20A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <13A @ 115VAC; <25A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <12A @ 115VAC; <20A @ 230VAC 6A 87% typ. 87% typ. 87% typ. 12 VDC 12-14 VDC 6.5A 70W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 20V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 9–11 V 11.0 V ±1.0 V (20 mA max.) rated: 30 VDC/1.0 A 12 VDC 12-14 VDC 13.0A 140W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 20V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 9–11 V 11.0 V ±1.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 3.75A 90W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (10 mA max.) rated: 30 VDC/1.0 A –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >1.8 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >1.2 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >1.8 Million hours, max. load by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 35 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.5kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 54 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.7kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 35 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.5kg UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc 28 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW PRO-H Series—Single Phase Input Supplies CP T SNT 180W 24V 7.5A L (+) N(- CP T SNT 600W 24V 25A + AC PE CP T SNT 360W 24V 15A DC - Ordering Data Type CP T SNT 180W 24V 7.5A Technical Data Input Specifications Input voltage Input voltage range Input voltage frequency Harmonic limits Hold up time Inrush current Recommended Circuit breaker, Curve 1 or fuse, slow blow type Efficiency Output Specifications Output voltage Output voltage adj. range Output current Output power max. Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Status indicator Power OK signal – trigger threshold: – active output signal: (reference to –Vout) – relay output General Specifications Operating temperature range Cooling Mounting Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 Remote On/Off (See LIT0917 - Installation Instructions) Isolation Environment – Vibration acc. IEC 60068-2-6 – Shock acc. IEC 60068-2-27 Dimension (W x D x H) Clearances – Above /Below – Sides Weight Approvals Part No. 1105810000 Type CP T SNT 360W 24V 15A Part No. 1105820000 Type CP T SNT 600W 24V 25A Part No. 1105840000 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <13A @ 115VAC; <25A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <16A @ 115VAC; <25A @ 230VAC 10A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <25A @ 115VAC; <30A @ 230VAC 15A 87% typ. 87% typ. 87% typ. 24 VDC 24-28 VDC 7.5A 180W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 15A 360W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 25A 600W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 54 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.7kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 80 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 1.1kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 165 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 2.8kg UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc 29 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW PRO-H Series—Single Phase Input Supplies CP T SNT 180W 48V 4A L (+) N(- CP T SNT 600W 48V 12.5A + AC PE CP T SNT 360W 48V 7.5A DC - Ordering Data Type CP T SNT 180W 48V 4A Technical Data Input Specifications Input voltage Input voltage range Input voltage frequency Harmonic limits Hold up time Inrush current Recommended Circuit breaker, Curve 1 or fuse, slow blow type Efficiency Output Specifications Output voltage Output voltage adj. range Output current Output power max. Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Status indicator Power OK signal – trigger threshold: – active output signal: (reference to –Vout) – relay output General Specifications Operating temperature range Cooling Mounting Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 Remote On/Off (See LIT0917 - Installation Instructions) Isolation Environment – Vibration acc. IEC 60068-2-6 – Shock acc. IEC 60068-2-27 Dimension (W x D x H) Clearances – Above /Below – Sides Weight Approvals Part No. 1105850000 Type CP T SNT 360W 48V 7.5A Part No. 1105860000 Type CP T SNT 600W 48V 12.5A Part No. 1105870000 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <13A @ 115VAC; <25A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <16A @ 115VAC; <25A @ 230VAC 10A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <25A @ 115VAC; <30A @ 230VAC 15A 87% typ. 87% typ. 87% typ. 48 VDC 48-56 VDC 4.0A 180W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 60V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 36-46 V 44.0 V ±4.0 V (15 mA max.) rated: 48 VDC/0.5 A 48 VDC 48-56 VDC 7.5A 360W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 60V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 36-46 V 44.0 V ±4.0 V (15 mA max.) rated: 48 VDC/0.5 A 48 VDC 48-56 VDC 12.5A 600W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 60V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 36-46 V 44.0 V ±4.0 V (15 mA max.) rated: 48 VDC/0.5 A –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 54 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.7kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 80 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 1.1kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 165 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 2.8kg UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc 30 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com NEW PRO-H Series—Diode Modules for Redundancy Redundancy Modules CP T RM 10 Redundancy Module With a redundancy module and two PRO-H Series power supplies (of same type) you can configure a highly reliable, truly redundant power system without any additional components. This module enforces the equivalent sharing of the output current by each power supply. The system is fully redundant and provides output power even if one power supply has completely failed e.g. by short circuit on the output. In the event that either power supply fails or is disconnected, the second unit will automatically supply the full current to the load. The redundancy of the system is monitored and if lost, indicated by an alarm output. The inputs are hot swappable and can be loaded up to 15A each. CP T RM 20 Redundancy Module Technical Data Input Specifications Input Input current Output Specifications Output voltage Output voltage adj. range Output power max. Output current General Data Status indicator Operating temperature Redundancy OK signal (Alarm) MTBF in acc. To IEC 61709 Alarm relay contact Environment - Vibration - Shock Dimension (W x D x H) Weight Remote link cable (0.5m) Remote On/Off 2 x 24 VDC 15A 2 x Control Input 25A 24 VDC 24-27 VDC 360 W 15A @ 24VDC, @ 40°C 24 VDC 24-27 VDC 600 W 25A @ 24VDC, @ 40°C LED – 25 °C to 70 °C max. (–13 °F...+158 °F) derating above 40 °C (104 °F): 1.5 %/K trigger threshold at 18...22VDC, contact open if both inputs failed >350,000 hours, max. load 30VDC/1A 3 axis, sine sweep, 10…55Hz, 1g, 1oct/min. 3 axis, 15g half sine, 11ms 35 x 110 x 110 mm 0.5kg 2 cables included by ext. contact: contact open = On, contact closed = Off LED – 25 °C to 70 °C max. (–13 °F...+158 °F) derating above 40 °C (104 °F): 1.5 %/K trigger threshold at 18...22VDC, contact open if both inputs failed >350,000 hours, max. load 3 axis, sine sweep, 10…55Hz, 1g, 1oct/min. 3 axis, 15g half sine, 11ms 54 x 110 x 110 mm 0.7kg 2 cables included by ext. contact: contact open = On, contact closed = Off II 3G Ex nA nC IIC t4 Gc Approvals II 3G Ex nA nC IIC t4 Gc Ordering Data Type CP T RM 10 Function Diagram Part No. 1105880000 + TSP J1.2 J1.1 J2 J2.3 J2.4 + J2.1 J2.2 _ Bottom view Output Load Output Remote Link 1 1 2 1 2 Volt adjust DC IN 2_ J1.4 Power Supplies Remote Link 2 J4 J3 J1.3 J4.1 TSP Top view 1 2 3 4 J3.1 J3.2 + Part No. 1105890000 Connector Positions Front view DC IN 1_ Type CP T RM 20 J5 REM Controller J4.2 1 DC IN 1 DC IN 2 J5.1 Alarm Redundancy ok J5.2 J5.3 2 3 4 J5.4 J1 Remote On/Off 1 2 3 4 J1 For detailed installation instructions, please visit www.weidmuller.com/power_supplies and download LIT0917 Pin Pin Pin Pin 1 2 3 4 Input 1 Input 1 Input 2 Input 2 J2 -Vin +Vin -Vin +Vin GND (-) GND (-) Vout (+) Vout (+) J3 Voltage Control 1 For Input 1 S+ S- J4 Voltage Control 2 For Input 2 S+ S- J5 DC-OK Signal DC-OK Relay Contact Remote ON/OFF Remote ON/OFF 31 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com connectPower—Single Phase Input Supplies CP SNT 55W CP SNT 160W Approvals: r ® LISTED % Diagram/Schematic Circuit Diagram Ordering Data Type Output voltage/maximum current Technical Data Input voltage Minimum Typical Maximum at 115 VAC at 230 VAC at 125 VDC at 250 VDC CP SNT 55W 24 VDC-28 VDC / 2.3 A 48 VDC / 1.04 A Part No. Type Part No. 9927480024 CP SNT 160W 24 VDC-28 VDC / 6.5 A 9925340024 9927480048 5 VDC / 10 A 9925340005 12 VDC - 15 VDC / 3 A 9927480012 12 VDC / 10 A 9925340012 5 VDC / 3 A 9927480005 48 VDC / 3.25 A 9925340048 85 VAC, 120 VDC 115-230 VAC ± 10%, 50/60 Hz 85 VAC / 195 VAC 115 VAC / 230 VAC ± 10%, (selectable) 50/60Hz 265 VAC, 300 VDC 1.10 A RMS ± 20% 0.55 A RMS ± 20% 590 mA ± 20% 315 mA ± 20% 138 VAC / 250 VAC 2.9 A RMS ± 20% 1.45 A RMS ± 20% 2 A slow fuse (internal, not user serviceable) Thermistor Varistor 100 kHz PWM 80% 0.1% RMS Vp-p 1.0% 6.3 A slow fuse (internal, not user serviceable) Thermistor Varistor 65 kHz PWM 85% 0.2% RMS Vp-p 2.0% Overload protection 0.8% Overcurrent shutdown with automatic restart plus thermal shutdown/short circuit 0.5% Overcurrent shutdown with automatic restart plus thermal shutdown/short circuit Output surge capability Maximum capacitance at output Parallel connection for load sharing 10,000 μF 13 A / 1 sec 6000 μF up to 3 devices (passive current division) 30 ms 30 ms 180 ms -40°C…+85°C (-40°F…+185°F) -20°C…+50°C (-4°F…+122°F) full rated load Derating: 24 V-1.5 A at 60°C (140°F) 20…85% RH non-condensing 20…90% RH 3 kV RMS 3 kV RMS 1.5 kV RMS 30 ms -40°C…+85°C (-40°F…+185°F) -10°C…+50°C (40°F…+122°F) max. full rated load Derating: 24 V-5.2 A at 60°C (140°F) 20…85% RH non-condensing 20…90% RH 3 kV RMS 3 kV RMS 1.5 kV RMS 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 98 x 57 x 131 mm (3.86 x 2.24 x 5.16 in.) 478 g (1.05 lbs.) 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 127 x 57 x 175 mm (5.00 x 2.24 x 6.9 in.) 880 g (1.94 lbs.) Horizontal on mounting rail TS35, Chassis 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) Horizontal on mounting rail TS35, Chassis 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) Changeover contact, 30 VDC / 125 VAC @ 1 A max. Passive Power Factor Correction CSA, UL 508 Listed, CE CSA Class 1 Div. 2 and Zone 2 for 9927480012 and 9927480024 UL 1310 (Class 2) for 9927480024 Part No. 7920560000 CSA, UL 508 Listed, CE CSA Class 1 Div. 2 and Zone 2 for 9925340024 and 9925340012 Input current (Average values for reference only) Input protection Switching frequency Efficiency at maximum load Maximum ripple Regulation Fuse Inrush Current Overvoltage load (10-100% load) at Input voltage Hold time (Maximum output current following input loss) Temperature Humidity Galvanic isolation at 115 VAC at 230 VAC Storage Operating Operating temperature Storage temperature Input-output Input/output to mounting rail Input to ground Output to ground Wire size Dimensions (L x W x H) Weight Mounting position Clearance Fault relay Approvals/Certifications Accessories Chassis Mounting Kit Side mount Bracket—DIN rail Part No. 7920560000 7940000542 32 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com connectPower—Single Phase Input Supplies CP SNT 300W Approvals: r ® LISTED % Diagram/Schematic Circuit Diagram Type Ordering Data CP SNT 300W Technical Data Input voltage Minimal Typical Input current at 300 W Topology Input protection Switching frequency Efficiency Output ripple Regulation 265 VAC, 200 VDC 3.3 A ± 10% at 230 VAC at 100 VDC 1.65 A ± 10% 3.7 A ± 10% at 200 VDC 1.85 A ± 10% 0.99 (under all load conditions) Sinusoidal (active power factor corrected) Fuse Inrush current Overvoltage at max.load Load (10-100%) Line (86-265 VAC RMS) Protection 86 VAC, 100 VDC 115-230 VAC ± 10% 50/60 Hz Maximum at 115 VAC Input power factor Input current Overvoltage Undervoltage Overload Output surge capability Thermal Adjustable output voltage Rated output current Part No. 9916250024 Boost PFC / forward PWM 5 A slow blow 5x20 mm Thermistor Varistor 100 kHz ± 5% 80% typical at 100 kHz: 2 mVp-p 1% 0.2% Vout > 30 VDC Vout < 14 VDC at Vout = 22 VDC, lout > 13.8 A 18.5 A / 300 mSec Heat sink temperature > 100°C (212°F) 22 VDC…28 VDC (pot. adj.) at Vout = 24 VDC, lout > 13.5 A at Vout = 28 VDC, lout > 11.6 A at Vout = 22 VDC…13.6 A at Vout = 24 VDC…12.5 A at Vout = 28 VDC…10.7 A LED indicator Shut down The 300 W power supply offers the following additional functions Current limiting: LED yellow Fault: LED red On: LED green Power supply goes to fault mode overvoltage, undervoltage or over temperature for more than 2 sec. fault relay drops out/short circuit – universal input voltage with PFC (active power factor corrections) – analog monitoring function of the output voltage 0…30 V corresponds to 0…10 V ± 3% Monitoring output impedance Load share Maximum capacitance at output Hold time of the output current 0…15 A corresponds to 0…10 V ± 3% of the internal temperature 0°C…+100°C (+32°F…+212°F) corresponds to 0…10 V ± 3% – Fault relay, 1 changeover, closed-circuit current principle 10 kM min. or 5 mA max. Current increase up to 60 A by wiring up to 5 300 W power supplies in parallel (active current division) 10,000 μF 30 ms 30 ms -40°C…+85°C (-40°F…+185°F) -20°C…+50°C (-4°F…+122°F) at 115 VAC at 230 VAC Storage Temperature Galvanic isolation Operating Derating Input-output Input/output to mounting rail Input to ground Output to ground Dimensions (L x W x H) Weight Mounting position Clearance Output current derating of approx. 20% at 60°C (140°F) 3 kV RMS 3 kV RMS 1.5 kV RMS 500 V RMS 104 x 240 x 155 mm (4.10 x 9.45 x 6.10 in.) 1180 g (2.60 lbs.) Horizontal on mounting rail TS35, chassis 20 mm left and right; 30 mm above and below if next to non-heat producing (low-power) module; 60 mm above and below if next to high heat producing module, (i.e. another power supply) Approvals/Certifications UL 508 Listed, CE, CSA Class 1, Div 2 and Zone 2 Part No. 79205600001) Accessories Chassis Mounting Kit 1) Order 2 mounting kits for power supply shown above. 33 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com c o n n e c t P o w e r — T h re e P h a s e I n p u t S u p p l i e s CP SNT 55W 2.3A 3 Phase Input CP SNT 160W 6.5A 3 Phase Input Approvals: r \ % Diagram/Schematic Circuit Diagram Ordering Data Type CP SNT 55W 2.3A 3 Phase 24 VDC / 2.3 A Output voltage/maximum current Technical Data Input voltage Minimum Typical Maximum at 360 VAC at 230 VAC Fuse Input current (Average values for reference only) Input protection Inrush Current Overvoltage Switching frequency Efficiency at maximum load Maximum ripple Regulation Load (10-100% load) at Input voltage Fault relay Output surge Overload protection Maximum capacitance at output Parallel connection for load sharing Hold time (Maximum output current following input loss) Temperature Humidity Galvanic isolation 9917790324 at 360 VAC at 480 VAC Storage Operating Input to ground Output to ground Type CP SNT 160W 6.5A 3 Phase 24 VDC-28 VDC / 6.5 A Part No. 9925340324 306 VAC 342 VAC 360 - 480 VAC 550 VAC 120 mA / Phase 100 mA / Phase 3 x 1 A slow fuse (internal) 480 VAC 528 VAC 0.36 A / Phase 0.34 A / Phase 3 x 12 A slow fuse (internal) Thermistor Varistor 100 kHz 85% 0.1% RMS 1.0% 0.8% Thermistor Varistor 100 kHz PWM 83% 0.2% RMS 2% 0.5% 10A / 180 ms typ. Overcurrent shutdown with automatic restart plus thermal Changeover contact, 30 VDC / 125 VAC @ 1 A max. 13A / 1 sec. Overcurrent shutdown with automatic restart plus thermal shutdown/short circuit 10,000 μF Operating Storage Input-output Input/output to mounting rail Wire size Dimensions (L x W x H) Weight Mounting position Clearance Part No. shutdown/short circuit 10,000 μF up to 3 devices (passive current division) 10 ms 15 ms -40°C…+85°C (-40°F…+185°F) -20°C…+50°C (-4°F…+122°F) 120 ms 120 ms -40°C…+85°C (-40°F…+185°F) -25°C…+50°C (-13°F…+122°F) full rated load Derating: 10% at 60°C (140°F) 20…85% RH non-condensing 20…90% RH non-condensing 3 kV RMS 3 kV RMS 20…85% RH non-condensing 20…90% RH 3 kV RMS 3 kV RMS 1.5 kV RMS 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 108 x 60 x 168 mm (4.25 x 2.36 x 6.61 in.) 526 g (1.16 lbs.) Horizontal on mounting rail TS35, Chassis 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) 1.5 kV RMS 500 V RMS 0.1…4.0 mm2 (26…12 AWG) 138.2 x 58.4 x 177.8 mm (5.44 x 2.3 x 7 in.) 993 g (2.2 lbs.) Horizontal on mounting rail TS35, Chassis 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) CSA, cULus 508 Listed, CE cULus 508 Listed, CE Approvals/Certifications Accessories Chassis Mounting Kit L Bracket Mounting Kit—Panelmount Side mount Bracket—DIN rail Part No. 7920560000 7940000543 Part No. 7920560000 7940000543 7940000542 34 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com connectPower—Diode Modules for Redundancy Ordering Data CP DM 30 (SP-RS-RED./PARR.30A) 15A per Input Diode Module RSD-40A 20A per Input or 40A Input per Unit Diode Module with Status Indication Type CP DM 30 with voltage sensing and fault relay Part No. 9987390000 Type RSD-40A (20 A per input max.) (2 x 20) Part No. 7940005219 CP DM 30 without voltage sensing 9987860000 RSD-40A (40 A input per unit max., 2 units required) (1 x 40) 7940005218 Technical Data Input Input voltage Output 14-24 VDC 24 VDC nominal Input current Output voltage 15 A per input max. 24 VDC 20 A per input max. / 40 A (7940005218) 24 VDC Output current 30A Maximum 40 A Maximum 0°C…+50°C (32°F…+122°F) (40°C rise (104°F) above ambient at 30 A) -20°C…+85°C (-4°F…+185°F) 0°C…+40°C (32°F…+104°F) ambient General Specifications Temperature Operating Storage Heat dissipation Efficiency under max. load Mount onto mounting rail 95% TS32 or TS35 mm DIN rails 12W @ 40A (7940005218 only) 95% TS32 or TS35 mm DIN rails Mounting position Mounting Horizontal Clearance: side 2 4 cm; above/below 2 10 cm Horizontal Clearance: side 2 4 cm; above/below 2 10 cm Weight Dimensions (L x W x H) Type of Connection 226.8 g (0.5 lbs.) 70 x 110 x 90 mm (2.75 x 4.33 x 3.5 in.) Screw 317.5 g (0.7 lbs.) 109.2 x 109.2 x 99 mm (4.3 x 4.3 x 3.9 in.) Screw Clamping area input (nominal / min. / max.) 4 / 0.32 / 16 mm2 (12 / 22 / 6 AWG) 1.5 / 0.32 / 16 mm2 (14 / 22 / 6 AWG) Clamping area output (nominal / min. / max.) Indication signals 4 / 0.32 / 16 mm2 (12 / 22 / 6 AWG) None for 998786 Actual voltage for 998739 1.5 / 0.32 / 16 mm2 (14 / 22 / 6 AWG) “AN.1” = input 1 (2 x 20 A version) “AN.2” = input 2 (2 x 20 A version) “AN.1” = “AN.2” = input voltage (1 x 40 A version) Voltage Alarm Fault Relay Other Terminations Voltage Current Configuration Set point Voltage drop input-output Fan Input/output Alarm contact “CATH” = output voltage 0-10 VDC = 0°C…+100°C (32°F…+212°F) 15 VDC Max. output (150°C [302°F]) 24 VDC under normal operating conditions 0 VDC if heatsink temperature exceeds 90°C (194°F) None 125 VAC Maximum 6 A Maximum 1 Form C / SPDT 14-24 VDC, ± 5% typ. 0.38 V typ. None N/A N/A N/A N/A 0.40 V typ. Turns on when heatsink temperature exceeds 60°C (140°F) Proportional control (fan speed increases as heatsink 2.5 mm2 (26…14 AWG) 26…12 AWG temperature increases–fully on at 80°C [176°F]) 13 mm2 (22…6 AWG) 26…14 AWG UL recognized, a cULus Listed Approvals/Certifications RSD-40A Schematics 7940005218 7940005219 OUT 1 OUT 2 OUT 3 OUT 4 IN 1 IN 2 Alarm & Fan Control OUT 1 OUT 2 OUT 3 OUT 4 IN 1 IN 2 AN.1 AN.1 AN.2 AN.2 CATH CATH Deg. C (0-10 VDC = 0-100°C) Alarm (0V = Deg. C > 90°C) Alarm & Fan Control Deg. C (0-10 VDC = 0-100°C) Alarm (0V = Deg. C > 90°C) COM (0V) COM (0V) 35 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — c o n n e c t P o w e r — D C - D C C o n v e r t e r s DC to DC converters enable customers to derive low voltage DC signals from either 12 VDC or 24 VDC sources. They are typically connected at the output of a DC power source and can deliver DC voltages of 5, 12, 15 or 24 volts. DC voltage converters (DC to DC converters) are intended in particular for the decentralized power supply of circuits, assemblies and modules. DC voltage converters are often required for emergency generators to supply electrical devices from batteries or other DC systems. DC-DC Converters • 12V and 24V input versions • Just 57mm (2.24”) wide • 5V, 12V, 15V and 24V output variations • Robust metal housing • User adjustable output voltage • Input and output plug-socket connectors • CSA Class 1 Div 2 and Zone 2 • UL508 listed • Output status LED • DIN rail (TS35) mountable • Chassis mountable with optional hardware The CP-DCDC 50W family is available in 2 input versions and 4 output versions, making them very versatile. Typical applications include feeding TTL level circuits (5 VDC) and providing emergency power to low voltage circuits. Remote Monitoring SUN Antenna Antenna Solar Cell 24VDC I/O Devices and Sensors I/O 24VDC Radio Transmitter 12V (powered) • DC-DC converter used to convert solar array output (24 VDC in this case) that is used for powering 24 VDC input/output devices, to 12 VDC used for power to lower cost radio transmitter. The transmitter panel (remote monitoring system) transmits information to SCADA system that can monitor the conditions/physical properties at the remote site, taking corrective actions, alarming, or simply providing information on conditions at remote site. 12VDC + + OUTPUT - 15VDC 3A - SCADA System or Other Type of Control System V out Adjust DC ON + - INPUT 12VDC ±15% 2.37A ±15% 24VDC 36 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com connectPower—DC-DC Converters CP-DCDC 50W 12 VDC Input CP-DCDC 50W 24 VDC Input Approvals: r v % Ordering Data Output voltage/maximum current Technical Data Input voltage Type CP-DCDC 50W 22 - 24 VDC @ 2 A 15 VDC @ 3 A 12 VDC @ 3 A 5 VDC @ 8 A Part No. 9919371224 Type CP-DCDC 50W 22-24 VDC @ 2 A Part No. 9919372424 9919371215 9919371212 15 VDC @ 3 A 12 VDC @ 3 A 9919372415 9919372412 9919371205 5 VDC @ 8 A 9919372405 12 VDC 10.2 VDC 24 VDC 18 VDC Typical Maximum 5 VDC @8A 12 VDC @3A 15 VDC @3A 12 VDC 16 VDC 4.53 A 3.88 A 4.7 A 24 VDC 30 VDC 2.3 A 1.93 A 2.37 A 24 VDC @2A Fuse 4.96 A internal (not user serviceable) 2 A 2.49 A internal (not user servicable) 2 A Switching frequency Efficiency at Maximum load 180 kHz PWM 80% (75% 5 VDC @8 A) 330 kHz PWM 80% (75% 5 VDC @8 A) Maximum ripple 0.2% RMS 0.2% RMS Overload protection Maximum capacitance at output Hold time 5 VDC @8A 12 VDC @3A 15 VDC @3A Overvoltage switch-off with automatic reset/short circuit 10,000 μF (8000 μF 5 VDC @8 A) 2.5 mS 3.8 mS 3.5 mS Overvoltage switch-off with automatic reset/short circuit 8000 μF 7.8 mS 10 mS 7 mS 24 VDC @2A Storage Operating 3.5 mS -40°C…+85°C (-40°F…+185°F) -10°C…+50°C (+14°F…+122°F) full rated load 7 mS -40°C…+85°C (-40°F…+185°F) -10°C…+50°C (+14°F…+122°F) full rated load 20…85% RH 20…90% RH non-condensing 500 VAC RMS 4 KV RMS 500 VAC RMS 20…85% RH 20…90% RH non-condensing 500 VAC RMS 4 KV RMS 500 VAC RMS 500 VAC RMS 500 VAC RMS 0.1…4.0 mm2 (26…12 AWG) 98 x 57 x 131 mm (3.86 x 2.24 x 5.16 in.) 454 g (1 lb.) Horizontal on mounting rail TS35, Chassis w/ optional kit 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) 0.1…4.0 mm2 (26…12 AWG) 98 x 57 x 131 mm (3.86 x 2.24 x 5.16 in.) 454 g (1 lb.) Horizontal on mounting rail TS35, Chassis w/ optional kit 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) CSA, UL Listed, CE CSA Class 1 Div. 2 and Zone 2 CSA, UL Listed, CE CSA Class 1 Div. 2 and Zone 2 Minimum Input Current for output of: Input protection Temperature Humidity Operating temperature Storage temperature Input to output Input/output to rail Input to ground Galvanic isolation Output to ground Wire size Dimensions (L x W x H) Weight Mounting position Clearance Approvals/Certifications Accessories Part No. Chassis Mounting Kit L Bracket Mounting Kit—Panelmount Part No. 7920560000 7940000543 7920560000 7940000543 37 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Introduction—connectPower—Battery Back Up Unit for DC Power Management Weidmuller’s Battery Back Up Unit (BBU) is designed to be the heart of an uninterruptible DC power management system. The connectPower BBU combines with Weidmuller power supplies and a customer-supplied battery pack to form a scalable DC power system. This enables users to put together a system uniquely tailored to their needs. Battery Back Up Units: These full-featured units have all the diagnostics needed to monitor the status of the power system. These DC power management units interface with the DC power supplies in the control cabinet. In addition, they monitor the status of the DC loads and the DC batteries. If the AC is removed or experiences a voltage sag, the load is switched seamlessly to the batteries. When the AC line is restored, the batteries are recharged and maintained. • Continuously monitors DC output voltage of power supply • DC backup system that actively manages DC battery banks • Increases system uptime by providing DC power to load in the event of an AC power failure • If the input fails, the load is switched seamlessly to batteries • Extensive monitoring is provided via LEDs and outputs With the BBU Power Supply, 2A of battery charging current is available at 24 VDC, and 3A with the 12 VDC units. Extensive monitoring is provided via LEDs. Relay contacts provide battery status indication and fault indication. Battery Back Up Unit for DC Power Management LOADS Battery Back Up Power Supply BATTERY + Battery BATTERY EXT. PS + 991628 0024 24VDC BATTERY BACK-UP UNIT r CLASS 1, DIVISION 2 GROUPS A, B, C &D T4A SEE SIDE PANEL EXT. PS LOAD + DC OUTPUT LOAD + LOAD - 15A MAX. LOAD - CHARGING FULL CHARGE BATTERY OPEN BATTERY LOW BATTERY REVERSE FAULT 115-230VAC. 1.0A-0.6A B.B.U. ONLY I MAX. = 10A (RMS) = B.B.U. + EXT. PS 50/60Hz + ENABLE + DRAIN + DRAIN RESET - COM BAT STATUS MAX. 1A @30VDC FAULT RELAY MAX. 1A @30VDC L IN g AC B.B.U. N L AC OUT g EXT. PS N % ® LISTED 9ZX0 AC INPUT r PS AC INPUT LGN BBU AC IN 38 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com connectPower—Battery Back Up Unit for DC Power Management BBU 12 VDC Input BBU 24 VDC Input Approvals: r v % Ordering Data Type BBU 12 VDC Part No. 9916280012 Type BBU 24 VDC Part No. 9916280024 Technical Data Input voltage Minimum Typical Maximum Input current Input protection Output to Load 85 VAC 115-230 VAC ± 10% 265 VAC 85 VAC 115-230 VAC ± 10% 265 VAC at 115 VAC at 230 VAC 0.8 A 0.5 A 1.0 A 0.6 A Fuse Input current 2 A slow blow (internal, not user serviceable) Thermistor 40 A maximum 2 A slow blow (internal, not user serviceable) Thermistor 40 A maximum Varistor 12 VDC syst. 15 A maximum Varistor 24 VDC syst. 15 A maximum 20 A max for 300 mS 30 A max for 100 mS 12-14 VDC 10 A maximum < 0.5 mS Limited by internal 4.0 A fuse 16 V 20 A max for 300mS 30 A max for 100mS 24-28 VDC 10 A maximum < 0.5 mS Limited by internal 4.0 A fuse 32 V 9.3 V 120°C (248°F) ±10% 18.3 V 120°C (248°F) +10% Overvoltage Voltage Nominal Load Current Surge Current from no load Load voltage AC input current Switching time from external PS to battery Protection Battery Polarity Protection Battery Overvoltage Battery Undervoltage BBU Over Temperature Shutdown Charger Short Circuit Continuous Continuous Load Short Circuit Storage Operating Storage Operating Continuous -20°C…+85°C (-4°F…+185°F) -20°C…+50°C (-4°F…+122°F) 20…90% 20…85% non-condensing Continuous -20…+85°C (-4°F…+185°F) -20…+50°C (-4°F…+122°F) 20…90% 20…85% non-condensing Input to output Input/output to rail 3 KV 3 KV 3 KV 3 KV 1.5 KV 500 V 0.1…4 mm2 (26…12 AWG) 0.5…1.5 mm2 (28…14 AWG) 1.5 KV 500 V 0.1…4 mm2 (26…12 AWG) 0.5…1.5 mm2 (28…14 AWG) Dimensions (L x W x H) 127.5 x 72.5 x 161 mm (5.02 x 2.85 x 6.34 in.) 127.5 x 72.5 x 161 mm (5.02 x 2.85 x 6.34 in.) Weight 950 g (2.09 lbs.) 950 g (2.09 lbs.) dry contact/open collector dry contact/open collector dry contact/open collector Form C Relay and LED Form C Relay and LED 3.0 A Regulates to 13.65 V LED dry contact/open collector dry contact/open collector dry contact/open collector Form C Relay and LED Form C Relay and LED 2.0 A Regulates to 27.3V LED LED Yellow LED on below 11 V 4 AH scalable, see example on page 41 Horizontal on mounting rail TS35 (optional direct panel mount) 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, LED Yellow LED on below 22 V 4 AH scalable, see example on page 41 Horizontal on mounting rail TS35 (optional direct panel mount) 20 mm left and right 30 mm above and below if next to non-heat producing (lowpower) module 60 mm above and below if next to high heat producing module, (i.e. another power supply) plug and socket (i.e. another power supply) plug and socket CSA, UL 508 Listed, CE, CSA Class 1 Div. 2 and Zone 2 Part No. 7920560000 CSA, UL 508 Listed, CE, CSA Class 1 Div. 2 and Zone 2 Part No. 7920560000 Temperature Humidity Galvanic Isolation Wire Size Control inputs Status outputs Battery Charger Battery Capacity Mounting position Clearance Connections Approvals/Certifications Accessories Chassis Mounting Kit Input to ground Output to ground Power Connections Control inputs/relay outputs Enable Drain Drain Reset Battery Status Fault Charge Current Full Charge Battery Reverse Battery Open Battery Low Minimum Maximum 39 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com connectPower—Battery Back Up Unit for DC Power Management—Operation Functional Outline The BBU is at its basic level a scalable UPS for 12 VDC or 24 VDC power. It is the heart or center of the system with everything wired through it. In this way it can monitor the status of the AC mains, the AC to the power supply, the DC out of the power supply and the battery condition. The BBU does NOT have built-in batteries. The batteries are sized based on the current and time demand for the back-up power. up current and the length of time that the current is required. There is no upper limit to the size of the batteries; we do not recommend that a battery pack smaller then 4Ahr be used due to the bulk charge rates of the BBU (3A for the 12V version and 2A for the 24V version), as they may be damaged with a bulk charge at this level. The BBU switches the output current from Power supply to Battery through an internal Mosfet. This allows the unit to switch over in milliseconds. The BBU has two form C relays, one for Battery status and the other for Fault monitoring. There are three inputs as follows: Enable, Drain and Drain Reset. These I/O are explained in detail below. The typical system is comprised of the following: the BBU, the battery pack and the power supply. The power supply is sized as per normal requirements (how much current is needed). The batteries are sized based on the amount of back- Under normal conditions the BBU operates as a battery charger. It trickles the batteries to a minimum voltage (if necessary) then bulk charges at a rate of 3A for the 12V version and 2A for the 24V version until the batteries reach 14.75V / 29.5V. At this point the BBU floats the batteries to 13.65V / 27.3V. Digital Inputs Diagnostic LEDs Relay Outputs Enable: A connection between the “Enable” and “COM” terminals enables the BBU. If terminals are open circuit (Disabled), the BBU functions as a battery charger only. In the event of AC failure the batteries are not connected to the load via the BBU. The BBU is factory preset as Enabled. Full Charged LED (green): On when battery voltage is 14.75/29.5V or greater. Bat Status relay is energized. Once fully charged the BBU drops the charge voltage to 13.65/27.3V (“float” voltage). Bat Status: Battery status, this changes state based on whether the batteries are charging or fully charged. See Diagnostic LEDs (Full Charge, Battery Low and Full Charge) for more detailed information. Battery Low LED (yellow): On when battery voltage is <11/22 VDC. Bat Status relay is off. If the battery voltage drops below 9.7/18.7V the load is switched off. Fault Relay: De-energizes under a fault condition. See Diagnostic LEDs (Fault LED, Battery Reverse, and Battery Open) for more detailed information. Drain: A temporary short between the “Drain” and “COM” terminals switches the load to the batteries until the battery voltage reaches 11/22V. At this point the AC power is returned to the power supply and the BBU starts recharging the batteries. The Drain cycle can also be reset / terminated by activating the “Drain Reset” input. Drain Reset: A temporary short between the “Drain Reset” and “COM” terminals disables the Drain cycle to the batteries. Charging LED (yellow): On when BBU is charging the batteries. Off when the “Full Charged” LED is on. Fault LED (red): On when AC fails. On when the external power supply voltage is <11V/21.5V. On when the batteries are not connected. On when the battery voltage is <9.7/18.7V. Fault relay de-energizes for the above conditions. Battery Reverse LED (red): Batteries connected in reverse. Fault relay de-energizes and fault LED turns on. There is an internal fuse that will open to prevent damage to BBU or to the batteries. Battery Open LED (red): No batteries connected – takes approx. 60 seconds to detect after turning on BBU. Fault LED is on and Fault relay is de-energized. 40 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com connectPower—Battery Back Up Unit for DC Power Management—Operation Typical Schematic • The 15A Critical Load limit is a limit of the BBU itself and not the power supply. • This schematic is representative of a 24 VDC system. For a 12 VDC system use a 12 VDC battery pack, a 12 VDC power supply and a 12 V BBU, part number 991628 0012. • The fuses may be replaced by another means of circuit protection, i.e. circuit breakers. • It is recommended to monitor the power supply Fault/Status relay/output if available. • The power supply shown is for illustration purposes only. The power supply needs to be chosen based on load requirements. Recommendations for Operation A drain cycle should be run as often as the application permits, six to twelve times per year is recommended. This allows the batteries to maintain their capacity, and it also allows you to validate their condition by monitoring the length of time that it takes to recharge. By knowing the capacity of the battery, you can calculate the approximate length of time that it will take to recharge by monitoring the “Bat Status” relay. Example 30Ahr battery at 24 VDC The 24 VDC BBU has a bulk charge current of 2A The formula to calculate the time to recharge a dead battery is: (30Ahr / 2A) x 2 = 30 hrs The formula to calculate the time to recharge after a drain cycle is: ((30Ahr / 2A) x 0.56) x 2 = 16.8 hrs The “x 2” in both formulas is because we overcharge the batteries so that they are fully charged—otherwise they only charge to just above 90%. When running a drain cycle, the system only discharges the batteries to 22V / 11V. The batteries still have a fair bit of capacity left. Please note that these formulas are NOT exact and are only approximations. This is due to variables such as actual battery capacity tolerance, temperature, voltage drop in cables, rate of discharge, etc. In systems that run 24/7, there is never a good time to run the drain cycle. In these cases it is recommended to upsize the batteries as much as possible. It is still recommended to run drain cycles in these conditions. This is one of the key features of this product allowing you to validate the condition of the batteries. Please keep in mind that the batteries are NOT completely drained by running a drain cycle. The drain cycle runs the batteries to a voltage of 22V / 11V. In the worst case scenario, if you happen to lose power during a drain cycle, the drain cycle will reset at a battery voltage of 22V /11V. The BBU will continue to power the load until the batteries reach 18V / 9V. Then and only then it will shut down power to the load. Because of this, and assuming that the batteries are bigger than needed, you shouldn’t have a situation that leaves you without power. We cannot stress how important it is to choose the batteries carefully for your application. The BBU is designed to work with many types of batteries, and works well with sealed lead acid, Gel cell and automotive / marine batteries. When selecting batteries keep in mind variables such as temperature extremes, cycle frequency (frequency of power outages) and many other environmental conditions. Many battery types can vent, creating a dangerous condition in a sealed panel. Please consult the battery manufacturer for recommendations specific to your application. The temperature to which batteries are subjected is very important. Many manufacturers do not recommend recharging batteries if they are colder then 0°C (32°F) or hotter then 40°C (104°F). Again, please consult the battery manufacturer for recommendations. It is recommended to use at least a 25% hysterisis on the calculated number of hours. Keep in mind that the battery capacity will decrease over time, and this is normal. The best thing to do is to run a test on a known good set of batteries at room temperature and base the midpoint on the actual number of hours it takes to recharge after a drain cycle. 41 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 1 0 - T Electronic circuit protection type ESX10-T is designed to ensure selective disconnection of 24VDC load systems. 24VDC power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. Upon detection of overload or short circuit in the load circuit, the MOSFET of the load output will be blocked to interrupt the current flow. The load circuit can be re-activated via the remote electronic reset input, control input or manually by means of the ON/OFF button. Through selective disconnection the ESX10-T responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESX10-T limits the highest possible current to 1.3 to 1.8 times the selected rated current of the circuit protector. Thus it is possible to switch on capacitive loads of up to 20,000 μF, but they are disconnected only in the event of an overload or short circuit. Features For optimal alignment with the characteristics of the application the current rating of the ESX10-T can be selected in fixed values from 0.5 A...12 A. Failure and status indication are provided by a multicolour LED and an integral shortcircuit-proof status output or a relay signal contact. Remote operation is possible by means of a remote reset signal or a remote ON/OFF control signal. The manual ON/OFF button allows separate actuation and reset of individual load circuits. • Manual ON/OFF button (S1) • Ease of wiring through busbar LINE+ and 0 V as well as signal bars and bridges • Control input IN+ for remote ON/OFF signal (option) • UL/CSA Hazardous area approved– Class 1, Div 2 • Selective load protection, electronic trip characteristics • Active current limitation for safe connection of capacitive loads up to 20,000 μF and on overload/short circuit • Clear status and failure indication through LED, status output SF or Si contact F • Integral fail-safe element adjusted to current rating • Current ratings 0.5 A...12 A • Width per unit only 12.5 mm • Reliable overload disconnection with 1.1 x In plus, even with long load lines or small cable cross sections (see table 3) • Rail mounting • Electronic reset input RE (option) 42 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 10 - T Approvals Technical data Authority UL2367 (E306740) UL1604 (E322549) (class 1, div. 2, group A, B, C, D) UL508/ cUL 508 CSA file 165971: CSA C22.2 No: 213 (class I, div. 2) Groups A, B, C, D, T5 CSA C22.2 No: 142 Class 2 Meets requirements for Class 2 current limitation (ESX10-T... 0.5 A / 1 A / 2 A / 3 A Voltage rating 24VDC 24VDC Current ratings 0.5...12 A 0.5...12 A 24VDC 0.5...12 A 24VDC 0.5...12 A 24VDC 0.5...12 A (Tambient = 40°C, operating voltage Ub = 24VDC) Status output SF Electrical data Status OUT OFF condition Technical data (Tambient = 40°C, operating voltage Ub = 24VDC) Operating data Operating voltage Ub Current rating In Closed current I0 Status indication by means of Load circuit Load output Overload disconnection Short-circuit current IK Trip time for electronic disconnection Temperature disconnection Low voltage monitoring load output 24VDC (18...32 V) fixed current ratings: 0.5, 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A, 12 A ON condition: typically 20...30 mA depending on signal output • multicolour LED: GREEN: unit is ON, power-MOSFET is switched on - status output SF ON, supplies + 24VDC ORANGE: in the event of overload or short circuit until electronic disconnection RED: - unit electronically disconnected - load circuit/Power-MOSFET OFF OFF: - manually switched off (S1 = OFF) or device is dead - undervoltage (Ub < 8 V) - after switch-on till the end of the delay period • status output SF (option) • potential-free signal contact F (option) • ON/OFF/ condition of switch S1 Power-MOSFET switching output (high side switch) typically 1.1 x In (1.05...1.35 x In) active current limitation (see table 1) see time/current characteristics typically 3 s at ILoad > 1.1 x In typically 3 s...100 ms at ILoad > 1.8 x In (or 1.5 x In/1.3 x In) internal temperature monitoring with electronic disconnection with hysteresis, no reset required load “OFF” at Ub < 8 V Starting delay tstart typically 0.5 sec after every switch-on and after applying Ub Disconnection of load circuit electronic disconnection Free-wheeling circuit external free-wheeling diode recommended with inductive load Several load outputs must not be connected in parallel Signal output F Electrical data ON condition LED green OFF condition LED off Fault condition LED orange Fault condition LED red ESX10-TB-101 ESX10-TB-102 Fault Reset input RE Electrical data Reset signal RE (terminal 22) Control input IN+ Electrical data Control signal IN+ (terminal 21) Switch S1 ON/OFF ESX10-TB-114/-124/ plus-switching signal output, connects Ub to terminal 12 of module 17plus nominal data: 24VDC / max. 0.2 A (short circuit proof) status output is internally connected to GND with a 10 kOhm resistor ESX10-TB-114/-124 (signal status OUT), at Ub = +24 V +24 V = S1 is ON, load output connected through 0V = S1 is ON, load output blocked and/or switch S1 is OFF red LED lit 0 V level at status output when: • switch S1 is in ON position, but device is still in switch-on delay • switch S1 is OFF, or control signal OFF, device is switched off • no operating voltage Ub ESX10-TB-101/-102 potential-free signal contact max. 30VDC/0.5 A, min. 10 V/10 mA voltage Ub applied, switch S1 is in ON position no overload, no short circuit • device switched off (switch S1 is in OFF position) • no voltage Ub applied overload condition > 1.1 x In up to electronic disconnection electronic disconnection upon overload or short circuit device switched off with control signal (switch S1 is in ON position) single signal, make contact contact SC/SO-SI open single signal, break contact contact SC/SO-SI closed signal output fault conditions: • no operating voltage Ub • ON/OFF switch S1 is in OFF position • red LED lighted (electronic disconnection) ESX10-TB-124 voltage: max. +32VDC high > 8VDC ≤ 32VDC low ≤ 3VDC > 0 V power consumption typically 2.6 mA (+24VDC) min. pulse duration typically 10 ms The electronically blocked ESX10-TB-124 may remotely be reset via an external momentary switch due to the falling edge of a +24 V pulse. A common reset signal can be applied to several devices simultaneously. Switched on devices remain unaffected. ESX10-TB-114 see reset input RE +24V level (HIGH): device will be switched on by a remote ON/OFF signal 0 V level (LOW): device will be switched off by a remote ON/OFF signal unit can only be switched on with S1 if a HIGH level is applied to IN+ 43 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 1 0 - T Technical data (Tambient = 40°C, operating voltage Ub = 24VDC) General data Fail-safe element: Mounting Ambient temperature Storage temperature Humidity backup fuse for ESX10-T not required because of the integral redundant fail-safe element LINE+ / LOAD+ / 0V Terminals screw terminals max. cable cross section flexible with wire end ferrule w/wo plastic sleeve multi-lead connection (2 identical cables) rigid/flexible flexible with wire end ferrule without plastic sleeve flexible with TWIN wire end ferrule with plastic sleeve wire stripping length tightening torque (EN 60934) Terminals aux. contacts screw terminals max. cable cross section flexible with wire end ferrule w/wo plastic sleeve wire stripping length tightening torque (EN 60934) Housing material moulded M4 symmetrical rail to EN 50022-35x7.5 0...+50 °C (without condensation, see EN 60204-1) -20...+70 °C 96 hrs/95 % RH/40 °C to IEC 60068-2-78-Cab climate class 3K3 to EN 60721 3 g, test to IEC 68-2-6 test Fc housing: IP20 DIN 40050 terminals: IP20 DIN 40050 emission: EN 61000-6-3 susceptibility: EN 61000-6-2 0.5 kV/2 pollution degree 2 re-inforced insulation in operating area max. 32VDC (load circuit) Vibration Degree of protection 20-6 AWG (0.5 - 10 mm2) 20-11 AWG (0.5 - 4 mm2) 20-13 AWG (0.5 - 2.5 mm2) 20-9 AWG (0.5 - 6 mm2) 10 mm 1.2 Nm EMC (EMC directive, CE logo) Insulation co-ordination (IEC 60934) dielectric strength Insulation resistance (OFF condition) Approvals n/a, only electronic disconnection UL2367, File E306740, Solid State Overcurrent Protectors UL1604 (class I, div. 2, zone 2), UL508, CE logo CSA C22.2 No. 142 - file 165971, C22.2 No. 213 - file 165971, C1D2 Groups A, B, C, D, Temp Code T5; Ambient 0°-40°C 12.5 x 80 x 83 mm approx. 65 g M3 23-13 AWG (0.25 – 2.5 mm2) 8 mm 0.5 Nm Dimensions (W x H x D) Mass Table 1: voltage drop, current limitation, max. load current current rating In 0.5 A 1A 2A 3A 4A 6A 8A 10 A 12 A typically voltage drop active current Uon at In limitation (typically) 70 mV 1.8 x In 80 mV 1.8 x In 130 mV 1.8 x In 80 mV 1.8 x In 100 mV 1.8 x In 130 mV 1.8 x In 120 mV 1.5 x In 150 mV 1.5 x In 180 mV 1.3 x In max. load current at 100% ON duty Tu = 40 °C Tu = 50 °C 0.5 A 0.5 A 1A 1A 2A 2A 3A 3A 4A 4A 6A 5A 8A 7A 10 A 9A 12 A 10.8 A Please note: • The user should ensure that the cable cross sections of the relevant load • Automatic start-up of machinery after shut down must be prevented circuit are suitable for the current rating of the ESX10-T used. (Machinery Directive 98/37/EG and EN 60204-1). In the event of a short circuit or overload the load circuit will be disconnected electronically by the ESX10-T. • Refer to UL/CSA file for proper wiring and installation techniques. Attention: when mounted side-by-side without convection the ESX10-T should not carry more than 80% of its rated load with 100% ON duty due to thermal effects. Table 2: ESX10-T - Ordering Information Version Signal input without Signal Input ESX10-TA-100 x ESX10-TB-101 x ESX10-TB-102 x Control input ON/OFF Reset Signal output Remote Reset without Signal Output Status output Status OUT Positive 24V = OK without Signal Output x x x x x x ESX10-TB-124 x x ESX10-TB-127 x x ESX10-TA-100 ESX10-TB-101 Circuit Protection Part Number Current Rating (amps) 0.5 6720005305 1 6720005301 2 3 ESX10-TB-102 N/O Contact Part Number Current Rating (amps) 0.5 6720005320 1 6720005321 6720005302 2 6720005303 3 4 6720005304 6 x x ESX10-TB-114* N/C Contact Part Number Current Rating (amps) 0.5 6720005340 1 6720005341 6720005322 2 6720005323 3 4 6720005324 6720005306 6 8 6720005308 10 12 ESX10-TB-124** Control Input Part Number Current Rating (amps) 0.5 6720005360 1 6720005361 6720005342 2 6720005343 3 4 6720005344 6720005326 6 8 6720005328 6720005310 10 6720005312 12 * Control force input on/off Status OUT ØV = OK x x ESX10-TB-114 Current Rating (amps) Signal contact single signal single signal N/O N/C (normally open NO) (normally closed NC) ESX10-TB-127 Reset Input Part Number Current Rating (amps) 0.5 6720005380 0.5 6720005309 1 6720005381 1 6720005319 6720005362 2 6720005382 2 6720005329 6720005363 3 6720005383 3 6720005339 4 6720005364 4 6720005384 4 6720005349 6720005346 6 6720005366 6 6720005386 6 6720005369 8 6720005348 8 6720005368 8 6720005388 8 6720005389 6720005330 10 6720005350 10 6720005370 10 6720005390 10 6720005399 6720005332 12 6720005352 12 6720005372 12 6720005392 12 6720005313 ** Reset input only to reset under fault conditions 44 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Reset Input Part Number E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 1 0 - T ESX10-T Signal inputs / outputs (wiring diagram) ESX10-TA-100 without signal input/output 1 LINE+ 2 ESX10-TB-101 without signal input with signal output F (single signal, N/O) LINE+ LOAD+ 1 SF 23 13 11 IN 21 LOAD+ 0V 2 3 operating condition: 13-14 closed fault condition: 13-14 open LINE+ LINE+ LOAD+ 0V 2 LOAD+ 0V 3 operating condition: 11-12 open fault condition: 11-12 closed 1 3 operating condition: SF +24 V = OK fault condition: SF 0 V Dimensions 12.5 .492 83 3.27 1 LINE LINE LOAD LOAD SF 23 RE 22 2 ESX10-TB-127 with reset input RE (+DC 24 V ↓) with inverse status output SF (0 V = load output ON) 1 SF 23 LINE+ 1 12 3 ESX10-TB-124 with reset input RE (+24VDC ↓) with status output SF (+24 V = load output ON) LINE+ 14 2 0V ESX10-TB-114 with control input IN+ (+24VDC) with status output SF (+24 V = load output ON) ESX10-TB-102 without signal input with signal output F (single signal, N/C) LOAD+ 0V 2 3 80 3.15 RE 22 LOAD+ 0V operating condition: SF +24 V = O fault condition: SF 0 V 80 3.15 3 operating condition: SF 0 V = OK fault condition: SF +24 V label snap-on socket for symmetrical rail EN 50022-35x7.5 mm This is a metric design and millimeter dimensions take precedence ( inch ) 45 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 1 0 - T Time/Current characteristic curve (Ta = 25 °C) • The trip time is typically 3 s in the range between 1.1 and 1.8 x In*1). disconnection typically 1.1 x In 1.8 x In *1) • Electronic current limitation occurs at typically 1.8 x In*1) which means that under all overload conditions (independent of the power supply and the resistance of the load circuit) the max. overload before disconnection will not exceed 1.8 x In*1) times the current rating. Trip time is between 100 ms and 3 sec (depending on overload or at short circuit). 10000 1000 100 trip time in seconds current limitation *1) typically 1.8 x In 10 5 • Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit. 1 0.1 0.01 0 1 2 3 5 IK 4 ...times rated current *1) current limitation typically 1.8 x In times rated current at In = 0.5 A...6 A current limitation typically 1.5 x In times rated current at In = 8 A or 10 A current limitation typically 1.3 x In times rated current at In = 12 A Table 3: Reliable trip of ESX10-T Reliable trip of ESX10-T with different cable lengths and cross sections Resistivity of copper ρ0 = Ub = DC 19.2 V (= 80 % of 24 V) 0.0178 (Ohm x mm2) / m voltage drop of ESX10-T and tolerance of trip point (typically 1.1 x In = 1.05 ... 1.35 x In) have been taken into account. ESX10-T-selected rating In (in A) 3 6 e. g. trip current Iab = 1.25 x In (in A) 3.75 7.5 Rmax in Ohm = (Ub / Iab) - 0.050 5.07 2.51 The ESX10-T reliably trips from 0 Ohm to max. circuitry resistance Rmax Cable cross section A in mm2 cable length L in meter (= single length) 0.14 ESX10-T trips after 3 s 0.25 0.34 0.5 0.75 1 1.5 cable resistance in Ohm = (R0 x 2 x L) / A 5 1.27 0.71 0.52 0.36 0.24 0.18 0.12 10 2.54 1.42 1.05 0.71 0.47 0.36 0.24 15 3.81 2.14 1.57 1.07 0.71 0.53 0.36 20 5.09 2.85 2.09 1.42 0.95 0.71 0.47 25 6.36 3.56 2.62 1.78 1.19 0.89 0.59 30 7.63 4.27 3.14 2.14 1.42 1.07 0.71 35 8.90 4.98 3.66 2.49 1.66 1.25 0.83 40 10.17 5.70 4.19 2.85 1.90 1.42 0.95 45 11.44 6.41 4.71 3.20 2.14 1.60 1.07 50 12.71 7.12 5.24 3.56 2.37 1.78 1.19 75 19.07 10.68 7.85 5.34 3.56 2.67 1.78 100 25.34 14.24 10.47 7.12 4.75 3.56 2.37 125 31.79 17.80 13.09 8.90 5.93 4.45 2.97 150 38.14 21.36 15.71 10.68 7.12 5.34 3.56 175 44.50 24.92 18.32 12.46 8.31 6.23 4.15 200 50.86 28.48 20.94 14.24 9.49 7.12 4.75 225 57.21 32.04 23.56 16.02 10.68 8.01 5.34 250 63.57 35.60 26.18 17.80 11.87 8.90 5.93 Example 1: max. length at 1.5 mm2 and 3 A Example 2: max. length at 1.5 mm2 and 6 A 106 m Example 3: mixed wiring: (Control cabinet – sensor/actuator level) R1 = 40 m in 1.5 mm2 and R2 = 5 m in 0.25 mm2: R1 = 0.95 Ohm, R2 = 0.71 Ohm Total (R1 + R2) = 1.66 Ohm 214 m 46 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 1 0 - T Mounting examples for ESX10-T The ESX10-T features an integral power distribution system. LINE+ busbar 6720005315 (12.5 x n)-3 = length of busbars ± 0.5 e. g. (12.5 x 5)-3 = 59.5 ± 0.5 continuous busbar 500 mm length, cut Up to 40 pole signal bar 6720005316 or jumper 6720005317 (2 pole only) remove protection against brush contact located on bottom side side walls or barriers for protection against brush contact on LINE+ and OV jumper locations insert protection against brush contact 0V busbar 6720005315 12.5 x n = width of protector block e. g. 12.5 x 5 = 62.5 insert busbars and protection slides to be flush with housing sides insert signal bars to be flush with housing and place them centrally over the contacts 5 ESX10-TB with busbars and jumpers 5 ESX10-TA with busbars Mounting procedure: Before wiring insert busbars into protection block. 47 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 1 0 - T Connection diagrams and application examples ESX10-T Signal contacts are shown in OFF or fault concition. ESX10-TA-100 ESX10-TB-101 group signaling (series connection) terminals for busbars screw terminals + line entry for the SI + line entry + line entry LINE+ busbar 1 LINE+ 1 LINE+ +24V 1 LINE+ LINE + busbar 1 LINE+ +24V 14 13 1 LINE+ 1 LINE+ 14 13 14 13 group signalling by means of an LED power supply DC 24 V ESX10-TA-100 ESX10-TA-100 ESX10-TA-100 power supply DC 24 V 0V 2 LOAD+ 2 LOAD+ jumpers are staggered 3 0V 3 0V 3 0V 0V ESX10-TB-101 ESX10-TB-101 ESX10-TB-101 2 LOAD+ 2 LOAD+ 2 LOAD+ 2 LOAD+ 3 0V 3 0V 3 0V 0 V busbar 0 V busbar - line entry - line entry + load - + - + load load - + - + load ESX10-TB-102 ESX10-TB-124 Single signaling with common line entry Single signaling with common reset + - load reset button single signalling per way by means of an LED + line entry for the SI - load single signalling per way by means of an LED + line entry + line entry LINE+ busbar LINE+ busbar 1 LINE+ 1 LINE+ +24V 12 11 1 LINE+ 12 11 12 11 power supply DC 24 V 22 signal busbar for common line entry ESX10-TB-102 ESX10-TB-102 0V 2 LOAD+ 2 LOAD+ 2 LOAD+ 3 0V 3 0V RE 23 SF 22 RE SF 1 LINE+ 23 22 RE SF ESX10-TB-124 0V ESX10-TB-124 ESX10-TB-124 2 LOAD+ 2 LOAD+ 2 LOAD+ 3 0V 3 0V 3 0V - line entry + load - + load - + load - signal busbar for common reset 0 V busbar 0 V busbar - line entry 23 power supply DC 24 V ESX10-TB-102 3 0V 1 LINE+ 1 LINE+ +24V + load - + load - + load 48 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com - E l e c t ro n i c C i rc u i t P ro t e c t i o n E S X 1 0 - T Accessories for ESX10-T Description Description Busbars for LINE+ and 0 V Part No. 6720005315 max. load with one line entry (recommended: centre line entry) Imax 50 A • LINE +(24VDC) max. load with two line entries Imax 63 A •0V length: 500 mm Signal busbars for signal contacts and reset inputs 6720005316 max. load with one line entry Imax 1A with one series connection of signal contacts Imax 0.5 A length: 500 mm Jumpers for signal contacts 6720005317 length: 21 mm packing unit: 10 pcs TS32 rail adapter 9102100000 The ESX10-T features an integral power distribution system. The following wiring modes are possible with various pluggable current and signal busbars: Caution: The electronic devices ESX10-T require a 0 V connection • signal contacts • reset inputs (Remove protection walls/barriers before using adapter.) For detailed installation instructions and approvals contact Weidmuller at 1-800-849-9343 or go to www.weidmuller.com 49 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — C i rc u i t P ro t e c t i o n Weidmuller’s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short circuits. Each circuit breaker has the ability to be reset without the need to change components. All circuit breakers are available with an assortment of jumpers and marking tags. Circuit breakers in the 9926 Series are cULus listed according to UL489 and CSA 22.2 No. 5.02, CE, VDE. The hydraulic magnetic trip mechanism offers 10,000A of interrupting capacity in 120V and 240V, 50/60Hz applications. 9926 Series The CB4200 Series of thermal magnetic circuit breakers feature a pushbutton style of trip reset. This reset provides a visual indication of status which allows for rapid troubleshooting. The CB2200 Series feature integrated alarm contacts within a narrow profile, thereby allowing increased enclosure capacity. All of these circuit breakers demonstrate consistent reliability through 100% calibration and testing, and feature a touch safe design to prevent injury from accidental contact with live components. CB2200 Series The CB9100 Series of thermal magnetic circuit breakers provide a rugged and industry-standard form factor (18 mm/pole). For supplemental circuit protection. CB4200 Series CB9100 Series 50 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – A C Ve r s i o n Circuit Breakers Hydraulic Magnetic Type 9926 Series Double Pole Single pole and double pole versions 120/240 VAC, 50/60 Hz Up to 25A Just 13 mm wide Mounts on 35mm DIN-rail cULus listed according to UL489 CSA C22.2 No. 5.02, CE, VDE Ordering Data Type: Single Pole (up to 120 VAC) Current Ratings Part No. (amps) TS 35 0.5 9926251000 Technical Data Description QL-1-13-DM-KM-0.5 Part No. TS 35 9926252000 Description QL-2-13-DM-KM-0.5 1 2 9926251001 9926251002 QL-1-13-DM-KM-01 QL-1-13-DM-KM-02 1 2 9926252001 9926252002 QL-2-13-DM-KM-01 QL-2-13-DM-KM-02 3 4 5 9926251003 9926251004 9926251005 QL-1-13-DM-KM-03 QL-1-13-DM-KM-04 QL-1-13-DM-KM-05 3 4 5 9926252003 9926252004 9926252005 QL-2-13-DM-KM-03 QL-2-13-DM-KM-04 QL-2-13-DM-KM-05 6 9926251006 QL-1-13-DM-KM-06 6 9926252006 QL-2-13-DM-KM-06 7 8 9926251007 9926251008 QL-1-13-DM-KM-07 QL-1-13-DM-KM-08 7 8 9926252007 9926252008 QL-2-13-DM-KM-07 QL-2-13-DM-KM-08 10 13 9926251010 9926251013 QL-1-13-DM-KM-10 QL-1-13-DM-KM-13 10 13 9926252010 9926252013 QL-2-13-DM-KM-10 QL-2-13-DM-KM-13 15 16 20 25 9926251015 9926251016 9926251020 9926251025 QL-1-13-DM-KM-15 QL-1-13-DM-KM-16 QL-1-13-DM-KM-20 QL-1-13-DM-KM-25 15 16 20 25 9926252015 9926252016 9926252020 9926252025 QL-2-13-DM-KM-15 QL-2-13-DM-KM-16 QL-2-13-DM-KM-20 QL-2-13-DM-KM-25 9926 Series AC Version - dimensions in mm (in.) Voltage Current minimum 120/240 VAC, 50/60Hz Although the 9926 series uses a magnetic only trip mechanism, CSA testing indicates a trip characteristic similar to thermal magnetic trip mechanisms. No de-rating is required at elevated temperatures. Additional trip curves and amp ratings are available upon request. Tripping Time 10 10 1 Seconds 1 1 0.1 0.1 0.01 0.01 0.001 0.001 4000 5000 0.4 1 10 2000 2500 3000 0.6 10 Ambient Temperature 30°C 1500 1.5 Ambient Temperature 30°C 1000 4 100 Minutes 100 400 500 28 Operating Characteristics Curve KM Operating Characteristics Curve 1 300 90 1000 1000 100 105 125 150 200 125% 150% 200% 400% 600% 800% 1000% minimum 15 8 4 0.7 0.09 0.007 0.005 (sec) 9926 Series–AC version Trip Curve 4000 5000 Sample trip characteristics - KM 57 (2.24) 9926 Series–AC version Trip Curve Tripping Time Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 45 (1.77) 64.8 (2.55) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. 92.8 (3.65) 28.5 (1.12) 5 (0.2) 2000 2500 3000 67101960 67101961 67101913 13 (0.51) 1500 Power lug, straight Power lug, 90° Lock-out handle 26 (1.02) 32 (1.26) 400 500 67101973 67101974 13 (0.51) 19 (0.75) 300 Bus-bar end cap, 1 pole Bus-bar end cap, 2 pole 71.4 (2.81) Operating temperature -40…+65°C Wire size* 0.5-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. Torque 20 in.-lb Approval cULus listed according to UL489 CSA C22.2 No. 5.02, CE, VDE Accessories Part No. Bus-bar (1 pole, insulated, 1 m) 67101904 Bus-bar (2 pole, insulated, 1 m) 67101972 Minutes 100MM 10000 mechanical operations 100 105 130 150 200 Insulation resistance Operating life 66 (2.6) Seconds 25A 10,000A 1500V, 50/60Hz 17.9 (0.7) 74 (2.91) 0.5A maximum Interrupting capacity Dielectric strength maximum 300 (sec) Type: Double Pole (up to 240 VAC) Current Ratings (amps) 0.5 1000 • • • • • • 9926 Series Single Pole (%) Rated Current (%) Rated Current Trip Curve 1 applies to the following part numbers where "XX" is the current rating: Single Pole— 99262512XX Double Pole— 99262522XX 51 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – A C Ve r s i o n w i t h C o n t a c t s Circuit Breakers with Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact† 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact)† • AC voltages (120/240V) • Single and double pole versions • cULus listed according to UL489 and C22.2 No. 5.02, CE, VDE • Factory fitted auxiliary or trip alarm • Compact 6.5mm width • Attached to right hand side of circuit breaker Technical Data Type: Single Pole Aux (up to 120 VAC) Voltage 120/240 VAC, 50/60Hz Current minimum maximum Current Ratings (amps) Part No. 1 9926261001 2 9926261002 5 9926261005 10 9926261010 15 9926261015 20 9926261020 25 9926261025 0.5A 25A Interrupting capacity 10,000A Dielectric strength Insulation resistance Operating life 1500V, 50/60Hz 100MM 10000 mechanical operations Operating temperature -40…+65°C Description QL-A-1-13-DM-KM-1 QL-A-1-13-DM-KM-2 QL-A-1-13-DM-KM-5 QL-A-1-13-DM-KM-10 QL-A-1-13-DM-KM-15 QL-A-1-13-DM-KM-20 QL-A-1-13-DM-KM-25 Type: Single Pole Combo (up to 120 VAC) Type: Single Pole Trip (up to 120 VAC) Current Ratings (amps) Part No. 1 9926271001 2 9926271002 5 9926271005 10 9926271010 15 9926271015 20 9926271020 25 9926271025 Current Ratings (amps) Part No. 1 9926281001 2 9926281002 5 9926281005 10 9926281010 15 9926281015 20 9926281020 25 9926281025 Description QL-T-1-13-DM-KM-1 QL-T-1-13-DM-KM-2 QL-T-1-13-DM-KM-5 QL-T-1-13-DM-KM-10 QL-T-1-13-DM-KM-15 QL-T-1-13-DM-KM-20 QL-T-1-13-DM-KM-25 Description QL-AT-1-13-DM-KM-1 QL-AT-1-13-DM-KM-2 QL-AT-1-13-DM-KM-5 QL-AT-1-13-DM-KM-10 QL-AT-1-13-DM-KM-15 QL-AT-1-13-DM-KM-20 QL-AT-1-13-DM-KM-25 Wire size* 0.5-15A: 20-25A: Torque 14AWG min., 10AWG max. 10AWG min. 20 in.-lb 9926 Series Double Pole Trip (Alarm Contact) 9926 Series Double Pole w/ Auxiliary Contact† Approval cULus listed according to UL489 and C22.2 No. 5.02, CE, VDE 9926 Series Double Pole Combination (Auxiliary & Alarm Contact)† †UL 489 listed (5A, 250 VAC; 0.5A, 80 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) IEC 60947-5-1 Approved (5A, 250 VAC; 0.5A, 110 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Type: Double Pole Aux (up to 240 VAC) Current Ratings (amps) Part No. 1 9926262001 2 9926262002 5 9926262005 10 9926262010 15 9926262015 20 9926262020 25 9926262025 Description QL-A-2-13-DM-KM-1 QL-A-2-13-DM-KM-2 QL-A-2-13-DM-KM-5 QL-A-2-13-DM-KM-10 QL-A-2-13-DM-KM-15 QL-A-2-13-DM-KM-20 QL-A-2-13-DM-KM-25 Part No. Description 9926272001 QL-T-2-13-DM-KM-1 9926272002 QL-T-2-13-DM-KM-2 9926272005 QL-T-2-13-DM-KM-5 9926272010 QL-T-2-13-DM-KM-10 9926272015 QL-T-2-13-DM-KM-15 9926272020 QL-T-2-13-DM-KM-20 9926272025 QL-T-2-13-DM-KM-25 Dual Mount Dimensions in mm (in.) 1000 Operating Characteristics Curve KM (N/O)16 (N/C)18 (C)15 Ambient Temperature 30°C TRIP ALARM Q. CONNECTORS 21.1 (0.83) 10 5.5 (0.22) 0.5 (0.02) Tripping Time Minutes 100 31.3 (1.23) 26.2 (1.03) 57.0 (2.24) 1 10 7 (0.28) 0.1 21.3 (0.84) 0.01 32.9 (1.3) 10.7 (0.42) 0.5 (0.02) 2.8 (0.11) 11(C) Seconds 14(N/O) AUX SWITCH Q. CONNECTORS 1 12(N/C) Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC Additional trip curves and amp ratings are available upon request. Type: Double Pole Combo (up to 240 VAC) Current Ratings (amps) Part No. 1 9926282001 2 9926282002 5 9926282005 10 9926282010 15 9926282015 20 9926282020 25 9926282025 2 (0.08) 9926 Series–AC version Trip Curve Type: Double Pole Trip (up to 240 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 125 150 200 0.001 (%) Rated Current 52 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Description QL-AT-2-13-DM-KM-1 QL-AT-2-13-DM-KM-2 QL-AT-2-13-DM-KM-5 QL-AT-2-13-DM-KM-10 QL-AT-2-13-DM-KM-15 QL-AT-2-13-DM-KM-20 QL-AT-2-13-DM-KM-25 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – D C Ve r s i o n Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole (80 VDC) 9926 Series Single Pole (125 VDC) • Single pole versions only • U2 trip curve for general purpose applications • 80 and 125 VDC • Up to 60A • Just 13 mm wide • Mounts on 35mm DIN-rail • UL 489A listed • VDE Type: Single Pole (80 VDC) Current Ratings (amps) 0.5 1 2 3 4 5 10 15 20 25 30 35 40 45 50 60 Accessories Part No. 9926251900 Description QY-1-13-DM-U2-0.5 9926251901 9926251902 9926251903 QY-1-13-DM-U2-01 QY-1-13-DM-U2-02 QY-1-13-DM-U2-03 9926251904 9926251905 QY-1-13-DM-U2-04 QY-1-13-DM-U2-05 9926251910 QY-1-13-DM-U2-10 9926251915 9926251920 9926251925 QY-1-13-DM-U2-15 QY-1-13-DM-U2-20 QY-1-13-DM-U2-25 9926251930 9926251935 QY-1-13-DM-U2-30 QY-1-13-DM-U2-35 9926251940 9926251945 9926251950 9926251960 QY-1-13-DM-U2-40 QY-1-13-DM-U2-45 QY-1-13-DM-U2-50 QY-1-13-DM-U2-60 9926 Series–DC version Trip Curve 9926251805 QY-1-13-DM-U2-05-B1 9926251810 9926251815 QY-1-13-DM-U2-10-B1 QY-1-13-DM-U2-15-B1 9926251820 9926251825 QY-1-13-DM-U2-20-B1 QY-1-13-DM-U2-25-B1 9926251830 QY-1-13-DM-U2-30-B1 9926251835 9926251840 9926251845 QY-1-13-DM-U2-35-B1 QY-1-13-DM-U2-40-B1 QY-1-13-DM-U2-45-B1 9926251850 9926251860 QY-1-13-DM-U2-50-B1 QY-1-13-DM-U2-60-B1 74 (2.91) 66 (2.6) 13 (0.51) 28.5 (1.12) 92.8 (3.65) Ambient Temperature 30°C 57 (2.24) Minutes Tripping Time 10 1 10 19 (0.75) 1 32 (1.26) 0.1 5 (0.2) 45 (1.77) 64.8 (2.55) 0.01 4000 5000 300 0.001 100 105 130 150 200 10,000 A 1500 V, 50/60 Hz 100 MM 10000 mechanical operations Operating temperature -40…+65°C Wire size* 1-15A: 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb Approval UL 489A Listed, CE, VDE Seconds Interrupting capacity Dielectric strength Insulation resistance Operating life QY-1-13-DM-U2-02-B1 QY-1-13-DM-U2-03-B1 QY-1-13-DM-U2-04-B1 Dimensions in mm (in.) Operating Characteristics Curve U2 DC (4% Ripple Factor) 100 80,125 VDC 0.5 A 60 A 9926251802 9926251803 9926251804 71.4 (2.81) 1000 Technical Data minimum maximum Description QY-1-13-DM-U2-01-B1 Additional trip curves and amp ratings are available upon request. 2000 2500 3000 67101973 67101960 67101961 67101913 1500 Bus bar end cap, 1 pole Power lug, straight Power lug, 90° Lock-out handle Part No. 9926251801 Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 1000 Part No. 67101904 400 500 Type Bus-bar (1 pole, insulated 1m) Voltage Current Type: Single Pole (125 VDC) Current Ratings (amps) 1 2 3 4 5 10 15 20 25 30 35 40 45 50 60 17.9 (0.7) Ordering Data (%) Rated Current *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. 53 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole 9926 Series Double Pole 9926 Series Triple Pole • AC Voltages 277/480V • Trip curve 2 for general purpose applications • UL 1077 recognized • VDE approved and CE marked • Just 13 mm wide • Mounts to 35 mm DIN-rail • Factory fitted auxiliary or trip alarm • Single, double and triple pole versions Ordering Data Type: Single Pole (up to 277 VAC) Current Ratings (amps) 1 2 3 4 5 6 8 10 15 20 25 35 40 50 60 Accessories Description QZ-1-13-D-2-01 QZ-1-13-D-2-02 9926251503 QZ-1-13-D-2-03 9926251504 9926251505 9926251506 QZ-1-13-D-2-04 QZ-1-13-D-2-05 QZ-1-13-D-2-06 9926251508 9926251510 QZ-1-13-D-2-08 QZ-1-13-D-2-10 9926251515 QZ-1-13-D-2-15 9926251520 9926251525 9926251535 9926251540 9926251550 QZ-1-13-D-2-20 QZ-1-13-D-2-25 QZ-1-13-D-2-35 QZ-1-13-D-2-40 QZ-1-13-D-2-50 9926251560 QZ-1-13-D-2-60 Part No. Description 9926252501 9926252502 QZ-2-13-D-2-01 QZ-2-13-D-2-02 9926252504 QZ-2-13-D-2-04 9926252505 9926252506 9926252510 QZ-2-13-D-2-05 QZ-2-13-D-2-06 QZ-2-13-D-2-10 9926252515 9926252520 QZ-2-13-D-2-15 QZ-2-13-D-2-20 9926252525 QZ-2-13-D-2-25 9926252530 9926252535 9926252540 9926252550 9926252560 QZ-2-13-D-2-30 QZ-2-13-D-2-35 QZ-2-13-D-2-40 QZ-2-13-D-2-50 QZ-2-13-D-2-60 Type: Triple Pole (up to 480 VAC) Current Rating (amps) 10 15 20 25 30 40 50 60 Part No. Description 9926253510 9926253515 QZ-3-13-D-2-10 QZ-3-13-D-2-15 9926253520 QZ-3-13-D-2-20 9926253525 9926253530 9926253540 QZ-3-13-D-2-25 QZ-3-13-D-2-30 QZ-3-13-D-2-40 9926253550 9926253560 QZ-3-13-D-2-50 QZ-3-13-D-2-60 9926 Series Supplemental – dimensions in mm (in.) 65 (2.56) 13 (0.51) 60 (2.36) 26 (1.02) 39 (1.54) 92.8 (3.65) 25.9 (0.94) 45 (1.77) 44 (1.73) 13 (0.51) 63.8 (2.51) 73 (2.87) 9926 Series–Supplemental Trip Curve Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 1 10 1 0.1 0.01 (%) Rated Current †cURus recognized to UL1077 and C22.2 No. 235 54 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 4000 5000 2000 2500 3000 1500 1000 0.001 400 500 The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit).The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Ambient Temperature 30°C 10 300 *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. Operating Characteristics Curve 2 100 Minutes Additional trip curves and amp ratings are available upon request. 1000 100 105 130 150 200 Technical Data Voltage 277/480 VAC @ 50/60 Hz Current minimum 0.5 A maximum 60 A Interrupting capacity 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V Dielectric strength 1500 V, 50/60 Hz Insulation resistance 100 MM Operating life 10000 mechanical operations Operating temperature -40…+65°C Wire size* 1-15A: 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb Approval †UL 1077 Recognized, VDE (EN 60947-2) Approved, CSA C22.2 No. 235, CE Marked Tripping Time 5.0 (0.2) 13 (0.51) Seconds Part No. 67101904 67101972 67101971 67101973 67101974 67101960 67101961 67101913 22.5 (0.86) Type Bus bar (1 pole, insulated 1m) Bus bar (2 pole, insulated 1m) Bus bar (3 pole, insulated 1m) Bus bar end cap, 1 pole Bus bar end cap, 2 pole or 3 pole Power lug, straight Power lug, 90° Lock-out handle Part No. 9926251501 9926251502 Type: Double Pole (up to 480 VAC) Current Rating (amps) 1 2 4 5 6 10 15 20 25 30 35 40 50 60 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s w i t h C o n t a c t s Circuit Breakers Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact‡ 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact)‡ • AC Voltages 277/480V • Trip curve 2 for general purpose applications • UL 1077 recognized • VDE approved and CE marked • Just 13 mm wide • Mounts to 35 mm DIN-rail • Factory fitted auxiliary or trip alarm • Single, double and triple pole versions Type: Single Pole Aux (up to 277 VAC) Technical Data Voltage 277/480 VAC @ 50/60 Hz Current minimum 0.5 A maximum 60 A Interrupting capacity 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V Dielectric strength Insulation resistance Operating life 1500 V, 50/60 Hz 100 MM 10000 mechanical operations Operating temperature -40…+65°C Wire size* 1-15A: Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926261501 9926261502 Description QZ-A-1-13-D-2-01 QZ-A-1-13-D-2-02 9926261505 9926261510 9926261515 QZ-A-1-13-D-2-05 QZ-A-1-13-D-2-10 QZ-A-1-13-D-2-15 9926261520 9926261525 QZ-A-1-13-D-2-20 QZ-A-1-13-D-2-25 Type: Single Pole Trip (up to 277 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926271501 9926271502 Description QZ-T-1-13-D-2-01 QZ-T-1-13-D-2-02 9926271505 9926271510 9926271515 QZ-T-1-13-D-2-05 QZ-T-1-13-D-2-10 QZ-T-1-13-D-2-15 9926271520 9926271525 QZ-T-1-13-D-2-20 QZ-T-1-13-D-2-25 Type: Single Pole Combo (up to 277 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926281501 9926281502 Description QZ-AT-1-13-D-2-01 QZ-AT-1-13-D-2-02 9926281505 9926281510 9926281515 QZ-AT-1-13-D-2-05 QZ-AT-1-13-D-2-10 QZ-AT-1-13-D-2-15 9926281520 9926281525 QZ-AT-1-13-D-2-20 QZ-AT-1-13-D-2-25 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb Approval †UL 1077 Recognized, VDE (EN 60947-2) Approved, CSA C22.2 No. 235, CE Marked 9926 Series Double Pole w/ Auxiliary Contact‡ 9926 Series Double Pole Trip (Alarm Contact) 9926 Series Double Pole Combination (Auxiliary & Alarm Contact)‡ ‡UL 489 listed (5A, 250 VAC; 0.5A, 80 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) IEC 60947-5-1 Approved (5A, 250 VAC; 0.5A, 110 VDC Auxiliary; 0.5A, 125 VDC Trip Alarm) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags.The part number for adhesive SchS2 is 1720600000. 9926 Series–Supplemental Trip Curve Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 1000 Type: Double Pole Aux (up to 480 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 Part No. Description 9926262501 9926262502 QZ-A-2-13-D-2-01 QZ-A-2-13-D-2-02 9926262505 QZ-A-2-13-D-2-05 9926262510 QZ-A-2-13-D-2-10 9926262515 9926262520 9926262525 QZ-A-2-13-D-2-15 QZ-A-2-13-D-2-20 QZ-A-2-13-D-2-25 9926 Series Triple Pole w/ Auxiliary Contact‡ Type: Double Pole Trip (up to 480 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 Part No. Description 9926272501 9926272502 QZ-T-2-13-D-2-01 QZ-T-2-13-D-2-02 9926272505 QZ-T-2-13-D-2-05 9926272510 QZ-T-2-13-D-2-10 9926272515 9926272520 9926272525 QZ-T-2-13-D-2-15 QZ-T-2-13-D-2-20 QZ-T-2-13-D-2-25 9926 Series Triple Pole Trip ( Alarm Contact) Type: Double Pole Combo (up to 480 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 Part No. Description 9926282501 9926282502 QZ-AT-2-13-D-2-01 QZ-AT-2-13-D-2-02 9926282505 QZ-AT-2-13-D-2-05 9926282510 QZ-AT-2-13-D-2-10 9926282515 9926282520 9926282525 QZ-AT-2-13-D-2-15 QZ-AT-2-13-D-2-20 QZ-AT-2-13-D-2-25 9926 Series Triple Pole Combination (Auxiliary & Alarm Contact)‡ Operating Characteristics Curve 2 Tripping Time Minutes 100 Ambient Temperature 30°C 10 1 10 Seconds 1 Type: Triple Pole Aux (up to 480 VAC) 0.1 0.01 (%) Rated Current †cURus recognized to UL1077 and C22.2 No. 235 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 130 150 200 0.001 Current Ratings (amps) 1 2 5 10 15 20 25 Part No. Description 9926263501 9926263502 9926263505 9926263510 9926263515 QZ-A-3-13-D-2-01 QZ-A-3-13-D-2-02 QZ-A-3-13-D-2-05 QZ-A-3-13-D-2-10 QZ-A-3-13-D-2-15 9926263520 9926263525 QZ-A-3-13-D-2-20 QZ-A-3-13-D-2-25 Type: Triple Pole Trip (up to 480 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 Part No. Description 9926273501 9926273502 9926273505 9926273510 9926273515 QZ-T-3-13-D-2-01 QZ-T-3-13-D-2-02 QZ-T-3-13-D-2-05 QZ-T-3-13-D-2-10 QZ-T-3-13-D-2-15 9926273520 9926273525 QZ-T-3-13-D-2-20 QZ-T-3-13-D-2-25 Type: Triple Pole Combo (up to 480 VAC) Current Ratings (amps) 1 2 5 10 15 20 25 Part No. Description 9926283501 9926283502 9926283505 9926283510 9926283515 QZ-AT-3-13-D-2-01 QZ-AT-3-13-D-2-02 QZ-AT-3-13-D-2-05 QZ-AT-3-13-D-2-10 QZ-AT-3-13-D-2-15 9926283520 9926283525 QZ-AT-3-13-D-2-20 QZ-AT-3-13-D-2-25 55 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s – G F C I Ground Fault Current Interrupt Ordering Data Description 73 (2.87) 65 (2.56) QF17A2505 - CB W/GFI QF17A2510 - CB W/GFI QF17A2515 - CB W/GFI QF17A2520 QF17A2525 QF17A2530 QF17A2550 - CB CB CB CB W/GFI W/GFI W/GFI W/GFI 9926 Series–AC version Trip Curve Technical Data Ground Leakage/GFCS 230 (CE) / 240 (UL) 5 kA 1000 Operating Characteristics Curve 2 Minutes 100 44 (1.73) Ambient Temperature 30°C 10 68.8 (2.71) 1 10 26 (1.02) 1 Seconds Approval UL 1077 and UL 1053, CE – 0.26 2 -40 to +65ºC Tripping Time Withstand Capacity (kA) Weight (kg) Trip Curve (standard) Operating Temperature Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 0.1 7.8 (0.307) Standard Ampere Ratings (A) 5 to 50A Sensitivity (mA) 30 (CE) / 22 (UL) Number of Poles 1+N Equipment Type Rated Voltage (V) Rated Interrupting/ 9926 Series GFCI – dimensions in mm (in.) Type: Single Pole GFCI Current Ratings (amps) Part No. 5 9926291105 10 9926291110 15 9926291115 20 9926291120 25 9926291125 30 9926291130 50 9926291150 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 130 150 200 0.001 16.4 (0.646) 8.0 (0.315) 71.4 (2.81) 0.01 26 (1.02) • (2.24) • • 57 • CE approved UL1077 and UL1053 recognized Small frame size (26mm wide) Single pole plus switched neutral ground leakage protection Trip point is unaffected by ambient temperature Current ratings up to 50A Trip indication (mid trip handle position) Trip curve 2 for general purpose applications 93 (3.66) 82.4 (3.24) • • • • 9926 Series GFCI (%) Rated Current 35.7 (1.406) 56 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 9926 Series Mounting Options and Accessories Mounting Options 93% 95 ON OFF 95 OF F ON OF F ON 5 N VERT 45 W ON OFF 100% ON VERT D 4 O R 5 N HO IZ DO 4 W 10 ON OF F ON OF F % ON OF F 5% 100% HORIZ 4 5 OFF UP UP It is important to note that in environments that are exposed to a high degree of vibration, the cables that connect to the circuit breaker must be securely held in place, as the breaker is not designed to carry the weight of the cables. A maximum of 35N can be applied to the terminal area, in a direction perpendicular to the mounting axis. % % If the product is not vertically mounted in the normal DIN-rail mounting orientation, a rating factor must be applied. Figure 1 shows a diagram of the rating factor to apply. The published curves for these circuit breaker products are produced with the circuit breaker in the vertical mounting position. The rating factor only applies to the must hold and must trip points of the curve as the other parts (instantaneous trip point) stay largely unaffected. 10 5 107% Accessories Technical Data Current Rating Voltage Part Number Table - Example 80A max. 500V max. Short Circuit Strength 25kA Type Part No. Bus bar (1 pole, insulated 1m) Bus bar (2 pole, insulated 1m) Bus bar (3 pole, insulated 1m) 67101904 67101972 67101971 To order 9926 Series Single Pole Circuit Breaker Part No. 9926251100 • Current Rating of 1.0 amp • Internal Resistance per Pole of 1.1 ohms • Trip Curve – M1, Medium (Standard) 9 9 2 6 2 5 1 0 0 0 Amperage Type "00" - 0.5A "01" - 1A "02" - 2A Part No. Bus bar end cap, 1 pole Bus bar end cap, 2 pole or 3 pole / "60" - 60A 67101973 67101974 Trip Curves (Types 5-9) "0" - Branch AC KM (Standard) "1" - Branch AC OP (Instantaneous) "2" - Branch AC 1 (Fast) "3" - Supplemental 9 (Slow) "4" - Branch 80VDC 1 (Fast) "5" - Supplemental 2 (Standard) "6" - Branch 125VDC OP (Instantaneous) "7" - Branch 80VDC OP (Instantaneous) "8" - Branch 125VDC U2 (Standard) "9" - Branch 80VDC U2 (Standard) Poles 1 Pole 2 Pole 3 Pole Technical Data Current Rating Wire Size Dimensions Type Power lug, straight Power lug, 90° 85A max. 10 AWG min., 4 AWG max. A: 6 mm B: 32 mm Type "5" - Base Breaker "6" - With Auxiliary Contact "7" - With Trip Alarm Contact "8" - Combo Aux/Trip Contact "9" - GFCI Part No. 67101960 67101961 9 9 2 6 2 4 1 0 0 0 Amperage Type Lock-out handle Part No. 67101913 "00" - 0.5A "01" - 1A "02" - 2A / "60" - 60A Trip Curves (Type 4) "0" - Supplemental 1 (Slow) "1" - Supplemental 3 (Fast) "3" - Branch AC 9 (Slow) Poles 1 Pole 2 Pole 3 Pole Type "4" - Base Breaker 57 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com C B 4 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Thermal Magnetic Type CB4200 Series Single Pole CB4200 Series Double Pole • Rated from 0.05 to 16.0 amps • Available in single or double pole configurations • Features a tease free design to reduce contact damage • Offers push button trip/reset function • Trip free design means the breaker cannot be held closed against a fault • Mounts on 32mm* or 35mm DIN-rail • UL 1077 recognized • CSA C22.2 No. 235 Ordering Data Type: Single Pole Type: Double Pole Current Ratings (amps) Part No. TS 35 *For TS 32 Rail, see adapter below Current Ratings (amps) Part No. TS 35 *For TS 32 Rail, see adapter below 0.05 9124083500 0.05 9124223500 0.08 9124653500 0.08 9124233500 0.1 9104173500 0.1 9120353500 0.2 0.3 0.4 9104183500 9129813500 9124093500 0.2 0.3 0.4 9124243500 9124263500 9124273500 0.5 9101003500 0.5 9129583500 0.6 9124113500 0.6 9124283500 0.7 0.8 1.0 1.2 1.3 9129563500 9101103500 9101203500 9101303500 9124123500 0.7 0.8 1.0 1.2 1.3 9124293500 9129593500 9129613500 9129623500 9124313500 1.4 1.5 9124133500 9101403500 1.4 1.5 9124323500 9129633500 1.8 2.0 2.5 3.0 3.5 9124143500 9101503500 9101603500 9101703500 9124163500 1.8 2.0 2.5 3.0 3.5 9124333500 9129643500 9129653500 9129663500 9124343500 4.0 4.5 5.0 9104353500 9124173500 9101803500 4.0 4.5 5.0 9129713500 9124353500 9129673500 5.5 6.0 6.5 7.0 8.0 9107833500 9103813500 9120043500 9104153500 9103003500 5.5 6.0 6.5 7.0 8.0 9124363500 9124373500 9124383500 9124393500 9104673500 9.0 10.0 9104613500 9101903500 9.0 10.0 9124423500 9129683500 11.0 12.0 9124183500 9107843500 11.0 12.0 9124433500 9124443500 13.0 14.0 15.0 16.0 9124193500 9107853500 9102003500 9124213500 13.0 14.0 15.0 16.0 9124453500 9124463500 9129693500 9124473500 Trip Curves Thermal Magnetic Type Typical time/current characteristics at 23ºC CB4200 Series *Adapter foot – dimensions in mm (in.) M1+ 0.05 to 7.5 A 100 Trip time in seconds 100 Trip time in seconds 1,000 10 1 10 TS32 adapter 0.1 0.01 0.01 0.001 2 3 4 6 8 10 20 30 … times rated current 50 70 100 9102100000 1 0.1 0.8 1 –30°C +23°C +55°C 20 –30°C +23°C +55°C 1,000 0.001 8 to 16 A 10,000 (.787) M1+ 10,000 0.8 1 2 3 4 6 8 10 20 30 50 70 100 … times rated current 58 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com C B 4 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s CB4200 Series Single Pole CB4200 Series Double Pole Internal Wiring Diagram Internal Wiring Diagram Dimensions in mm Technical Data Rated voltage & current† UL Voltage Ratings AC 250 V, DC 65 V, 50/60 Hz Current Ratings 0.05…16 A CSA VDE AC 250 V, DC 65 V, 50/60 Hz AC 250 V, DC 65 V, 50/60 Hz 0.05…16 A 0.05…16 A Creepage resistance Dielectric strength Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) PTI 600 to IEC 112 4,000 VAC; IEC 664 & 664 A > 100 MM (DC 500 V) Interrupting capacity; 4201 (UL 1077/EN 60934 PC1) 4201-10 0.05…0.8 A 1…2 A 2.5…16 A Rated current Maximum capacity Self-limiting 200 A 400 A Rated voltage Maximum capacity 0.05…2.0 A 2.0…16 A 20 A AC 250 V AC 250 V AC 125 V 200 A 200 A 400 A Typical life at 2 x rated current Shock Torque 5,000 operations 25 g (11 ms) to IEC 68-2-27, Test Ea 1.2 Nm Vibration Temperature range 5 g (57 to 500 Hz / ±0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc -30°C…+55°C (-22°F…+131°F) Corrosion Humidity Weight Wire size (UL) 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca 60 g per pole #20…8 AWG solid/0.5…6 mm2 Accessories Jumpers Daisy Chain 50* Straight CQB** insulated Angled CQB** insulated Adapter foot (for TS 32 Rail) Busbar Busbar end cap for 6720000227 Power lug for 6720000227 Dimensions in mm Type Part No. BDC 50 9970290000 CQB CQB CQB CQB CQB 2 3 4 10 2 9970560000 9970570000 9970580000 9970590000 9970600000 CQB 3 CQB 4 CQB 10 MCBAF/TS 32 9970610000 9970620000 9970630000 9102100000 6720000227 6720000225 6720000226 WS 8/5 MC DEK 5/5 DEK 5/5 1640750000*** 0473460001 0473560001 Single pole 1 meter Marking Tags Note: Part numbers are shown for a single card of pre-printed tags numbered 1-50. Special print only Consecutive horizontal Consecutive vertical †Note: Resistive and inductive loads (0.05 - 16 A) *BDC will accommodate 20 A per pin, 20 A total **CQB will accommodate 18 A per pin, 18 A total; dedicated to 4201 Series ***Please specify horizontal or vertical print when ordering. Standard quantity = 144 tags per card. 59 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com C B 2 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Thermal Magnetic Type CB2200 Series Single Pole CB2200 Series Double Pole CB2200 Series Triple Pole • Rated from 0.1 to 32.0 amps • Available in single, double and triple pole configurations • Offers normally open (N/O) and normally closed (N/C) auxiliary contacts • Lever-switch trip/reset function • Mounts on 32mm or 35mm DIN-rail • UL 1077 recognized • CSA C22.2 No. 235 Ordering Data Type: Single Pole* Type: Double Pole Type: Triple Pole Current Ratings (amps) 0.1 N/O Aux. Part No. 9911010005 Current Ratings (amps) 0.1 N/O-N/C Part No. 9912010003 Current Ratings (amps) 0.1 N/O-N/C Part No. 9913010003 0.2 0.3 0.4 9911020005 9911030005 9911040005 0.2 0.3 0.4 9912020003 9912030003 9912040003 0.2 0.3 0.4 9913020003 9913030003 9913040003 0.5 0.6 9911050005 9911060005 0.5 0.6 9912050003 9912060003 0.5 0.6 9913050003 9913060003 0.8 1.0 9911080005 9911100005 0.8 1.0 9912080003 9912100003 0.8 1.0 9913080003 9913100003 1.5 2.0 2.5 9911150005 9911200005 9911250005 1.5 2.0 2.5 9912150003 9912200003 9912250003 1.5 2.0 2.5 9913150003 9913200003 9913250003 3.0 4.0 5.0 6.0 8.0 10 12 9911300005 9911400005 9911500005 9911600005 9911800005 9921100005 9921120005 3.0 4.0 5.0 6.0 8.0 10 12 9912300003 9912400003 9912500003 9912600003 9912800003 9922100003 9922120003 3.0 4.0 5.0 6.0 8.0 10 12 9913300003 9913400003 9913500003 9913600003 9913800003 9923100003 9923120003 15 16 18 9921150005 9921160005 9921180005 15 16 18 9922150003 9922160003 9922180003 15 16 18 9923150003 9923160003 9923180003 20 9921200005 20 9922200003 20 9923200003 25 32 9921250005 9921320005 *All part numbers with N/O Auxiliary Contacts on each pole when the main breaker contact is open (in the OFF position) Ordering Data Type: Single Pole Type: Double Pole Type: Triple Pole All part numbers with N/C Auxiliary Contacts on each pole when the main breaker contact is open (in the OFF position) Current Ratings Current Ratings Current Ratings (amps) Part No. (amps) Part No. (amps) Part No. 0.1 9911010000 0.1 9912010000 0.1 9913010000 0.2 9911020000 0.2 9912020000 0.2 9913020000 0.3 9911030000 0.3 9912030000 0.3 9913030000 0.4 9911040000 0.4 9912040000 0.4 9913040000 0.5 9911050000 0.5 9912050000 0.5 9913050000 0.6 0.8 1.0 1.5 2.0 9911060000 9911080000 9911100000 9911150000 9911200000 0.6 0.8 1.0 1.5 2.0 9912060000 9912080000 9912100000 9912150000 9912200000 0.6 0.8 1.0 1.5 2.0 9913060000 9913080000 9913100000 9913150000 9913200000 2.5 9911250000 2.5 9912250000 2.5 9913250000 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 9911300000 9911400000 9911500000 9911600000 9911800000 9921100000 9921120000 9921150000 9921160000 9921180000 9921200000 9921250000 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 9912300000 9912400000 9912500000 9912600000 9912800000 9922100000 9922120000 9922150000 9922160000 9922180000 9922200000 9922250000 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 9913300000 9913400000 9913500000 9913600000 9913800000 9923100000 9923120000 9923150000 9923160000 9923180000 9923200000 9923250000 32 9921320000 32 9922320000 32 9923320000 60 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com C B 2 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s CB2200 Series Trip Curves—Thermal Magnetic Type Typical time/current characteristics at 23ºC CB2200 Series F1 0.1 to 32 A 10,000 –30°C +23°C +55°C Trip time in seconds 1,000 100 10 1 0.1 0.01 0.001 .8 1 3 4 2 6 8 10 20 30 50 70 100 …times rated current -M1 0.1 to 7.5 A 10,000 –30°C AC +23°C DC +23°C +55°C Technical Data UL Voltage Ratings 277 / 480 VAC (50/60 Hz); 65 VDC Current Ratings 0.1…32 A CSA VDE 277 / 480 VAC (50/60 Hz); 65 VDC 250 / 415 VAC / 65 VDC 0.1…32 A 0.1…32 A Auxiliary contacts Creepage resistance Dielectric strength 250 VAC / 65 VDC, 1 A PTI 600 to IEC 112 3,000 VAC; IEC 664 & 664 A Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) > 100 MM (DC 500 V) Rated current Rated voltage 0.05…0.8 A 250 / 415 VAC 6…32 A 250 / 415 VAC Rupture capacity (3 times) 400 A 800 A Interrupting capacity (UL 1077/EN 60934 PC1) Rated current 0.1…16 A 20…32 A 0.1…32 A Max. rupture capacity (3 times) 5000 A 2000 A 2000 A Rated voltage 277 / 480 VAC 277 / 480 VAC 65 VDC Nm (lb. in.) AC .8 1 2 3 4 6 8 10 -M1 20 30 50 70 100 –30°C AC +23°C DC +23°C +55°C 1,000 100 10 DC 0.1 AC 0.001 .8 1 0.6 (5.3) Auxiliary contact: 0.5 (4.4) 5 g (57 to 500 Hz / ±0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc Part No. 9970290000 1 pole (CB2200) 2 pole (CB2200) 9986510000 9987360000 2 3 4 6 8 10 20 30 50 70 100 …times rated current -T1 0.1 to 7.5 A 10,000 –30°C +23°C +55°C 1,000 Trip time in seconds Type BDC 50, 20 A maximum 8 to 32 A 10,000 0.01 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca Approximately 60 g per pole max 6 mm2…8 AWG max 1.5 mm2…14 AWG (Aux. contact) Daisy Chain 50 DC …times rated current -30…+60°C (-22°F…+140°F) Accessories Jumpers Busbars 10 0.01 0.001 5,000 operations 25 g (11 ms) to IEC 68-2-27, Test Ea Typical life at 2 x rated current Shock Torque Vibration Temperature range Corrosion Humidity Weight Wire size (UL) 10 0.1 Trip time in seconds Rated voltage & current† 100 T Dimensions in mm Trip time in seconds 1,000 100 10 0.1 0.01 Marking Tags 1 2 3 4 5 6 Note: Part numbers shown are for a single card of pre-printed tags numbered 1-50. Special print only Consecutive horizontal Consecutive vertical DEK 5/6 DEK 5/6 0490360000* 0468660001 DEK 5/6 0468760001 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 …times rated current -T1 8 to 32 A 10,000 †Note: Resistive and inductive loads (0.05 - 16 A) *Please specify horizontal or vertical print when ordering. –30°C +23°C +55°C Trip time in seconds 1,000 100 10 1 0.1 0.01 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 …times rated current 61 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com C B 9 1 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Thermal Magnetic Type CB9100 Series Single Pole CB9100 Series Double Pole CB9100 Series Triple Pole • Rated from 0.5 to 63 amps • Available in single, double and triple pole configurations • Optional auxiliary contacts • Mounts on 35mm DIN-rail • UL and CSA approvals • CSA 277 VAC (1 pole) or 480 VAC (2 and 3 pole) • 50 VDC (0.5 A to 50 A) 1 pole • 110 VDC (0.5 A to 50 A) 2 pole Ordering Data Type: Single Pole Current Ratings (amps) 0.5 1.0 2.0 3.0 4.0 6.0 10.0 13.0 16 20 25 32 40 50 63 Type: Double Pole Part No. Current Ratings (amps) 9925350000 9925360000 0.5 1.0 9925380000 9925390000 9925400000 9925410000 Type: Triple Pole Part No. Current Ratings (amps) Part No. 9925650000 9925660000 0.5 1.0 9925810000 9925820000 2.0 9925680000 2.0 9925840000 3.0 4.0 6.0 9925690000 9925700000 9925710000 3.0 4.0 6.0 9925850000 9925860000 9925870000 9925430000 10.0 9925730000 10.0 9925890000 9929820000 9925440000 13.0 16 9929830000 9925740000 13.0 16 9929840000 9925900000 9925450000 9925460000 20 25 9925750000 9925760000 20 25 9925910000 9925920000 9925470000 9925480000 9925490000 32 40 50 9925770000 9925780000 9925790000 32 40 50 9925930000 9925940000 9925950000 9925500000 63 9925800000 63 9925960000 Trip Curves Thermal Magnetic Type Typical time/current characteristics at 23°C CB9100 Series M1 0.5 to 6 A 10,000 M1 AC 10 to 40 A 10,000 M1 10,000 23°C 23°C 23°C 100 100 100 1 Trip time in seconds 1,000 Trip time in seconds 1,000 Trip time in seconds 1,000 10 10 1 10 1 0.1 0.1 0.1 0.01 0.01 0.01 0.001 0.8 1 2 3 4 6 8 10 20 30 … times rated current 50 70 100 AC 63 A 0.001 0.8 1 2 3 4 6 8 10 20 30 … times rated current 50 70 100 0.001 0.8 1 2 3 4 6 8 10 20 30 50 70 100 … times rated current 62 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com C B 9 1 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s CB9100 Series 70 45 54 44 36 18 59 1 pole 2 pole 6 3 pole 86 Dimensions in mm Internal Wiring Diagram Auxiliary Contact Modules Technical Data Rated voltage & current UL 1077 277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole) CSA C 22.2 No. 235 277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole) 91.4 VDE 80.6 Creepage resistance PTI 250 to IEC 112 Insulation resistance Interrupting capacity (UL 1077/EN 609334 PC1) 1 pole >100 MM at 500 VDC Current ratings 0.5...63 A Mechanical/Electrical endurance Shock 0.5...32 A 0.5...63 A 0.5...50 A 20,000/10,000 20 g (10 ms) Torque 2 Nm Vibration Temperature range - operating 3 g (10 to 55 Hz) -25°C...+55°C (-13°F to 131°F) Weight Strip length Auxiliary contact rating Wire size - #22…12 AWG 1 pole (130 g); 2 pole (280 g); 3 pole (430 g) 12 mm Voltage AC 220/240 5.8 Interrupting Rupture capacity (3X) 10,000 A (UL) Voltage 277 VAC/50 VDC 2,000 A (UL) 6,000 A (UL) 6,000 A (UL) 277 / 480 AC 50 VDC (1) pole 110 VDC (2) poles 45.2 Current 5A Type Accessories Jumpers 9 Current Side/Middle Part No. 3 pole bus, 10 x 1010 mm, buses (19) 3 phase groupings 3 pole bus, 16 x 210 mm, buses (4) 3 phase groupings 80A/100A 120A/130A 9970330000 9970340000 3 pole bus, 16 x 1010 mm, buses (19) 3 phase groupings 1 pole bus, 12 x 210 mm, buses 12 breakers 120A/130A 80A/100A 9970350000 9970360000 1 pole bus, 12 x 210 mm (insulated), buses 12 breakers Bus bar clamp 5 69 AC 277 3A DC 24 V 4A DC 60 V 1A DC220 V 0.4 A #18…2 AWG (line); #18…3 AWG (load) Wire size 44 44 63A 130A Internal Auxiliary Wiring Diagram 9991990000 9970370000 14 12 11 Auxiliary contacts SPDT Security hardware Auxiliary contacts 9970300000 Lock out cover 9970380000 ETO 10/26, yellow (26 mm x 10 mm) 1686401687 Marking Tags Adhesive label 63 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — M C Z O v e r v o l t a g e P ro t e c t i o n Slim overvoltage protection terminals for instrumentation and control engineering Weidmuller MCZ ovp overvoltage protection terminals are characterized by their high level of protection concentrated in a compact space of 6 mm. The tension clamp connection and direct grounding via the terminal rail contact results in timesavings during installation. The MCZ ovp terminals are suitable for installing in the narrowest of places in automated process, industrial and building services systems. The different models MCZ ovp CL is a three-stage protective combination with a suppression diode between the current paths. It limits the overvoltage in analog signal circuits, e.g. current loops. MCZ ovp SL is a three-stage protective combination with two suppression diodes, each from the signal line to ground. It limits the overvoltage in binary circuits, e.g. for actuators. MCZ ovp CL FG is a three-stage protective combination with a suppression diode between the current paths. It limits the overvoltage in analog signal circuits. A high-resistance ground connection is achieved with a gas discharge tube. MCZ ovp SL FG is a three-stage protective combination with two suppression diodes, each from the signal line to ground. It limits the overvoltage in binary circuits, e.g. for actuators. A high-resistance ground connection is achieved with three gas discharge tubes. MCZ ovp filter terminals contain selected varistors, capacitors and series inductances. They form reliable noise filters. Coupled interference in the kHz range is safely discharged to ground. For example, the signal inputs of a PLC, which can be protected against interference voltages and RF interference. The three-stage overvoltage protection terminals are fitted with gas discharge tubes, varistors, suppression diodes (TAZ) and decoupling inductors. Individual protective components such as varistors and suppression diodes complement the range. EMC regulations require the terminal rail to be securely screwed to a grounded mounting plate. Optimum protection is achieved when the PE contact is made via a tension clamp terminal every 600 mm. Derating curve MCZ ovp filter loading current in A The MCZ ovp overvoltage protection terminals are available with rated voltages of 24, 48, 115 and 230 V. The ground contact is produced by clipping the terminal to a grounded terminal rail. To guarantee a safe energy discharge of up to 10 kA (8/20 μs) via these terminals, the TS 35 DIN rail must therefore be grounded. mounted on rail without clearance mounted on rail with clearance 20 mm ambient temperature in °C Derating curve MCZ ovp filter Derating curve MCZ ovp filter loading current in A derating curve 1,25 A mounted on rail without clearance mounted on rail with clearance 20 mm ambient temperature in °C 64 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP CL 24 V DC 0.5 A Protection for current loops MCZ OVP CL 24 V AC 0.5 A Protection for current loops • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 1 4 U 5 5 TS TS U IN Ordering data 2 3 2 Type 3 OUT Qty. 10 Part No. Type Version MCZ OVP CL 24VDC 0.5A Technical data Rated voltage (AC) Rated voltage (DC) 24 V 24 V 28 V max. continuous voltage, Uc Operating current, Imax Volume resistivity 28 V 0.50 A 2.50 Ω 38 V 0.50 A 1.00 Ω Gas discharge tube Varistor yes yes yes yes Suppression diodes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. yes 500.0 kHz 240 Ω 2.5 kA 40 V 65 V 40 V 65 V yes 500.0 kHz 240 Ω 2.5 kA 45 V 70 V 45 V 70 V Design Type of connection terminal tension clamp connection terminal tension clamp connection Storage temperature, min./max. Operating temperature, min./max. -25 °C/85 °C -25 °C/60 °C -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve 8448920000 MCZ OVP CL 24VAC 0.5A Qty. 10 Part No. 8472880000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 8389030000 65 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP CL 24 V UC 1.25 A Protection for current loops MCZ OVP SL 24 V DC 0.5 A Protection for binary signals • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 1 4 5 5 TS TS 2 3 Qty. 10 Part No. 8448960000 2 Ordering data Version Type MCZ OVP CL 24VUC 1.25A Type MCZ OVP SL 24VDC 0.5A Technical data Rated voltage (AC) 24 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 24 V 27 V 1.25 A 24 V d 28 V 0.50 A Volume resistivity Gas discharge tube Varistor Suppression diodes 1.00 Ω yes yes yes 2.50 Ω yes yes yes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 500.0 kHz 240 Ω 2.5 kA 80 V 130 V 40 V 65 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 500.0 kHz 240 Ω 2.5 kA 80 V 130 V 40 V 65 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve 3 Qty. 10 Part No. 8448940000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 66 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 8389030000 M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP SL 24 V UC 1.25 A Protection for binary signals MCZ OVP CL 48 V UC 0.5 A Protection for current loops • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 1 5 4 5 TS TS 2 2 3 Ordering data Version Type MCZ OVP SL 24VUC 1.25A Qty. 10 Part No. 8448970000 Type MCZ OVP CL 48VUC 0.5A Technical data Rated voltage (AC) 24 V 48 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 24 V 28 V 1.25 48 V 53 V 0.50 A Volume resistivity Gas discharge tube Varistor Suppression diodes 1.00 Ω yes yes yes 2.50 Ω yes yes yes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 500.0 kHZ 240 Ω 2.5 kA 80 V 130 V 40 V 65 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 500.0 kHz 240 Ω 2.5 kA 80 V 150 V 80 V 150 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve 3 Qty. 10 Part No. 8449000000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 8389030000 67 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP SL 48 V UC 0.5 A Protection for binary signals MCZ OVP CL 48 V UC 1.25 A Protection for current loops • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 1 4 4 5 5 TS TS 2 2 3 Ordering data Version Type MCZ OVP SL 48VUC 0.5A Qty. 10 Part No. 8449030000 Type MCZ OVP CL 48VUC 1.25A Technical data Rated voltage (AC) 48 V 48 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 48 V 53 V 0.50 48 V 53 V 1.25 A Volume resistivity Gas discharge tube Varistor Suppression diodes 2.50 Ω yes yes yes 1.00 Ω yes yes yes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 500.0 kHz 240 Ω 2.5 kA 160 V 300 V 80 V 150 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 500.0 kHz 240 Ω 2.5 kA 80 V 150 V 80 V 150 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve 3 Qty. 10 Part No. 8449040000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 68 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 8389030000 M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP SL 48 V UC 1.25 A Protection for binary signals MCZ OVP CL 115 V UC 1.25 A Protection for current loops • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 1 4 5 5 TS TS 2 3 Qty. 10 Part No. 8449050000 2 Ordering data Version Type MCZ OVP SL 48VUC 1.25A Type MCZ OVP CL 115VUC 1.25A Technical data Rated voltage (AC) 48 V 115 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 48 V 53 V 1.25 115 V 127 V 1.25 A Volume resistivity Gas discharge tube Varistor Suppression diodes 1.00 Ω yes yes yes 1.00 Ω yes yes yes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 500.0 kHZ 240 Ω 2.5 kA 160 V 300 V 80 V 150 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 500.0 kHz 240 Ω 2.5 kA 220 V 360 V 220 V 360 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve 3 Qty. 10 Part No. 8449060000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 8389030000 69 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP SL 115 V UC 1.25 A Protection for binary signals MCZ OVP CL 230 V UC 1.25 A Protection for current loops • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 5 1 4 5 TS TS 2 3 3 OUT 2 IN Ordering data Version Type MCZ OVP SL 115VUC 1.25A Qty. 10 Part No. 8449070000 Type MCZ OVP CL 230VUC 1.25A Technical data Rated voltage (AC) 115 V 230 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 115 V 127 V 1.25 A 230 V 250 V 1.25 A Volume resistivity Gas discharge tube Varistor Suppression diodes 1.00 Ω yes yes yes 1.00 Ω yes yes yes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 500.0 kHz 240 Ω 2.5 kA 440 V 720 V 220 V 360 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 500.0 kHz 240 Ω 2.5 kA 420 V 710 V 420 V 710 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve Qty. 10 Part No. 8449080000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 70 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 8389030000 M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ SL FG 24 V AC 0.5 A not grounded MCZ CL FG 24 V AC 0.5 A not grounded • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV Ordering data Version Type MCZ OVP SL FG 24VAC 0.5A Qty. 10 Part No. 8823280000 Type MCZ OVP CL FG 24VUC 0.5A Technical data Rated voltage (AC) 24 V 24 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 24 V 28 V 0.50 A 24 V 28 V 0.50 A Volume resistivity Gas discharge tube Varistor Suppression diodes 1.00 Ω 90 V / 10 kA 30 V 2.50 Ω 90 V / 10 kA 30 V Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 500.0 kHz / 240 Ω 2.5 kA 40 V 65 V 40 V 65 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 500.0 kHz / 240 Ω 2.5 kA 40 V 65 V 40 V 65 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve Qty. 25 Part No. 8704240000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 8389030000 71 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP SL 230 V UC 1.25 A Protection for binary signals MCZ OVP 24 V 0.5 A Filter • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 4 5 5 TS TS 3 OUT 2 IN Ordering data 1 Type Qty. 10 Part No. IN Type Version MCZ OVP SL 230VUC 1.25A Technical data Rated voltage (AC) Rated voltage (DC) 230 V 230 V 24 V 24 V max. continuous voltage, Uc Operating current, Imax Volume resistivity Gas discharge tube Varistor 250 V 1.25 A 1.00 Ω yes yes 26 V 0.50 A 1.50 no yes Suppression diodes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. yes 500.0 kHz 240 Ω 2.5 kA 840 V 1420 V no 50.0 kHz 50 Ω 0.5 kA 140 V 190 V Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. 420 V 710 V terminal tension clamp connection -25 °C/85 °C 70 V 100 V terminal tension clamp connection -25 °C/85 °C Operating temperature, min./max. -25 °C/60 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve 8449090000 3 OUT 2 MCZ OVP FILTER 24V 0.5A Qty. 10 Part No. 8449100000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 72 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 8389030000 M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP 90 V Gas discharge tube MCZ OVP S10K30 Varistor S10K30 • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 1 4 5 5 TS TS 2 IN 3 OUT Part No. 8449130000 2 3 OUT IN Ordering data Version Type Qty. MCZ OVP gas charge eliminator, 90 V 10 Type MCZ OVP VARISTOR S10K30 Technical data Rated voltage (AC) 50 V 24 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 70 V 72 V 16.00 A 24 V 30 V 16.00 A Volume resistivity Gas discharge tube Varistor Suppression diodes 0.20 Ω 90 V / 10 kA no no 0.20 Ω no yes no Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 2.5 kA 700 V 800 V 700 V 800 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 125 45 V 55 V 45 V 55 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve Qty. 10 Part No. 8449140000 Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 8389030000 73 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com M C Z O v e r v o l t a g e P ro t e c t i o n 3- or 1-stage protection with tension clamp connection MCZ OVP TAZ 24 V DC Diode unipolar MCZ OVP TAZ 24 V UC Diode bipolar • Slimline overvoltage protection terminal with tension clamp connection • 6 mm Slimline fine overvoltage protection • fast wiring thanks to TS contact and tension clamp connections • can be cross-connected using ZQV 1 4 4 5 5 TS TS 2 3 OUT IN Ordering data Version 1 Type MCZ OVP TAZ DIODE 24VDC Qty. 10 Part No. 8449150000 Technical data Rated voltage (AC) 3 OUT 2 IN Type MCZ OVP TAZ DIODE 24VUC Qty. 10 Part No. 8449160000 24 V Rated voltage (DC) max. continuous voltage, Uc Operating current, Imax 24 30 16.00 A 27 V 27 V 16.00 A Volume resistivity Gas discharge tube Varistor Suppression diodes 0.20 Ω no no yes 0.20 Ω no no yes Cut-off frequency (-3 dB) at load impedance Discharge current, max. (8/20 μs) Protection level on output side sym., input 1 kV/μs, typ. Protection level on output side sym., input 8/20 μs, typ. Protection level on output side unsym., input 1kV/μs, typ. Protection level on output side unsym., input 8/20 μs, typ. Design Type of connection Storage temperature, min./max. Operating temperature, min./max. 112 55 V 65 V 55 V 65 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C 0.5 kA 55 V 65 V 110 V 130 V terminal tension clamp connection -25 °C/85 °C -25 °C/60 °C CE; UL listed CE; UL listed tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 tension clamp connection 1.5 / 0.5 / 1.5 91 x 6 x 63.5 Note: see derating curve Note: see derating curve Approvals Dimensions Clamping range (rating- / min. / max.) Length x width x height Accessories End plate mm2 mm AP MCZ 1.5 8389030000 AP MCZ 1.5 74 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 8389030000 I n t ro d u c t i o n — S u r g e P ro t e c t i o n D e v i c e s SD Series SLP Series Data and Signal Protection The SD Series are ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling, and the SLP Series provides 20kA power surge protection for process control, equipment systems and distribution panels. Product Features: • Range of ATEX Certified intrinsically safe surge protectors • Ultra-slim and space saving designs; easy installation • Multistage hybrid protection circuitry - 10kA maximum surge current for SD Series, and 20kA maximum surge current for SLP Series • Range of voltage ratings ideal for process I/O applications • Designed for high bandwidth, low resistance applications; RTD, Public Switch Telephone Network (PSTN) and 3-wire transmitter versions available in SD Series MA15 Series AC & DC Power Protection The MA15 Series of surge protection devices protects electronic equipment and computer networks against the effects of noise pollution induced in power supplies. MA15 units filter out and suppress the effects of industrial noise and surges caused by lightning, switching devices, thyristor controls, transmission system overloads and power-factor correction circuits. • Surge protection for two loops or one 4-wire circuit per SLP Series module • 10 year product warranty The SD and SLP Series surge protection devices provide unparalleled packing densities, application versatility, proven and reliable hybrid circuitry, simple installation and optional ‘loop disconnect’ facilities (SD Series). These features make the SD and SLP Series the ultimate surge protection solutions for process control equipment, I/O systems and communications networks. Product Features: • 18kA surge protection and RFI filtering TP48 Series • Protects panel loads up to 15 Amps in series, unlimited Amps in parallel Transmitter and Sensor Protection • Suitable for AC or DC application • Thermal and short circuit protection • LED status indication feature • 10 year product warranty The TP48 Series of transmitter protectors safeguards electronic process transmitters against induced surges and transients from field cabling. They uniquely provide a level of protection for 2, 3 and 4 wire field-mounted transmitters that greatly exceeds the optional transient protection facilities available from the transmitter manufacturers without any additional wiring, conduit modifications or other expensive extras. Product Features: • Easy and direct mounting – simply screw into spare conduit entry • Intrinsically safe; flameproof to CENELEC standards; ATEX approved • Parallel connection avoids introduction of resistance into loop 75 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com I n t ro d u c t i o n — S u r g e P ro t e c t i o n D e v i c e s SD Series SLP Series The exceptionally high packing densities are the result of an ultra slim footprint for individual modules, which can double-up as feedback terminals. Each module provides full hybrid surge protection for 2 and 3-wire loop protection. The multi-stage hybrid surge protection network at the heart of the SLP uses a combination of solid state electronics and a gas filled discharge tube (GDT) to provide surge protection up to 20kA. This impressive surge protection circuit is designed to exhibit exceptionally low line resistance and adds only a minimal voltage drop to the circuit. Modules with a comprehensive range of voltage ratings cover all process related signals such as RTDs, Thermo- couples (THCs), 4 - 20mA loops, telemetry outstations, shut-down systems and fire and gas detectors. The optional loop disconnect featured on the SD07, SD16, SD32 and SD55 modules allows users to perform commissioning and maintenance without removing the surge protection device. In addition, a third connection on the field and safe side of the module is provided for safe termination of shields. For three wire applications the specially designed SDRTD (Resistance Temperature Detector) and the SD32T3, (for separately powered 4 - 20mA loops) provide full 3-wire protection in a single compact unit. The SD07R3 provides protection of 3-wire pressure transducers on low power circuits. For higher bandwidth applications, the SDR Series meets the demands of today’s highest speed communication systems. The SLP device does not adversely affect the performance or operation of the loop or combined equipment during operation. The device allows signals to pass with very little attenuation, while diverting surge currents safely to the ground and clamping output voltages to safe levels. Fully automatic in operation, SLP devices react immediately to ensure that equipment is never exposed to damaging surges between lines or the lines and ground. Reacting instantly, the SLP redirects surges safely to the ground and resets automatically. The versatile SLP series provides full hybrid surge protection, combining protection for two process loops into one case. For higher bandwidth applications, the SLP series has been developed to meet the demands of today’s highest speed communication systems. 120V and 240V AC versions are available for I/O and power supplies up to three Amps of load current. Publc Switched telephone networks can be protected by the SDPSTN. All modules are DIN-rail mountable on a TS-35 rail. A comprehensive range of mounting and grounding accessories are available. 76 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — S D S e r i e s SD Series Guide to applications and selection The SD Series of signal protection devices includes models for a full range of applications operating at voltages up to 250V ac. The optional fuse/disconnect package provides both fused protection against fault currents and a convenient method of isolating field circuitry from protected circuitry without requiring additional disconnect terminals. The standard fuse (replaceable) is rated 250mA. 50mA fuses are available by special request. Solid links can be used in applications where only the disconnect feature is required. This feature is important in applications where a signal protection device is used with a bulk power supply feeding multiple loops. The individual fuse module prevents a fault or follow on current on one loop disrupting the power supply to the others. In addition, loops can be removed from the circuit for maintenance or added without requiring additional disconnect terminals. The following guide provides application information for the SD series. For technical information, see page 84. PROTECTED CIRCUIT FIELD CIRCUIT Analog inputs (high-level) Bulk PSU 2-wire transmitters, 4-20mA, conventional and smart SD32 and SD55 are recommended for use with conventional and smart 4-20mA transmitters (fed by a well-regulated supply), the choice dependent upon the maximum working voltage of the system (32V and 55V respectively). The diagram illustrates an application using the fuse/disconnect. Both models are available in ‘X’ versions without the optional fuse/disconnect feature. 1 Up to 50V dc 4/20mA 1 to 5V 2 4 TP48 transmitter protector 5 6 3 SD32 SD55 SD32X SD55X (no fuse) Multiple Loops 2-wire transmitters Analog inputs (low-level) SDRTD RTDs, Thermocouples (THCs) and mV sources using the SDRTD. 1 4 5 For optimum accuracy, the energizing current should be chosen to ensure the voltage across the RTD does not exceed 1V over the full measurement range. When using a PT100 device, an energizing current of 1mA is recommended. Recorder Controller Computer etc. 2 6 3 SDRTD 3-wire RTDs 2xSD07X or 2xSD16X Photocells and turbine flowmeters Depending upon the operational voltage, the SD07 or SD16 are the preferred choices for this application. SD07X and SD16X are also suitable. 1 4 Photocell Thermocouple (THC) Signal 5 mV source 2 Turbine Flowmeter 6 3 SD07 SD16 SD07X SD16X (no fuse) photocells, thermocouples (THCs), mV sources and turbine flowmeters 77 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — S D S e r i e s Analog outputs PROTECTED CIRCUIT FIELD CIRCUIT Controller outputs (I/P converters) 2xSD15X, SD32X Dependent on the working voltage, recommendations include the SD16, SD32 and SD55, and the equivalent ‘X’ versions. 1 4 P V I 5 2 6 OV 3 SD16 SD32 SD35 SD16 SD32X SD55X (no fuse) Controller outputs (I/P converters) Digital (on/off) inputs - Switches SD Suitable signal protection devices include the SD07, SD16, SD32 and SD55 modules, and the equivalent “X” versions. The choice is dependent upon the operating voltage of the system. 1 4 5 V 2 6 Logic Signal 3 SD07 SD16 SD32 SD55 SD07X SD16X SD32X SD55X OV (no fuse) Switches Digital (on/off) outputs Alarms, LEDs, solenoid valves, etc. SD32X 1 4 LED Alarm 5 The SD32 or SD32X are the recommended choice for this application. 32V max 2 6 3 SD32 SD32X (no fuse) Alarms, LEDs, solenoid values, etc. 4 Incoming Telephone Line Telemetry Public Switch Telephone Network (PSTN) - Telemetry outstations 1 5 Modem, fax or telephone 2 6 3 The SDPSTN has been designed specifically for the protection of signals transmitted on public switched telephone networks. Telecom line AC supplied equipment - PLC, I/O systems 4 110/120V ac or 220/240V ac The recommended choice or systems on 110-120V ac is the SD150X ; for 220-240V ac systems, the SD275X is recommended. 5 PLC, DCS, SCADA, etc. 2 6 3 PLC, I/O systems 78 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 Final output from 1 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — S D S e r i e s Transmitter and sensor protection Transmitters and sensors are widely used in highly exposed areas and where lightning damage is common. In many cases, the ideal solution for 2-wire transmitters or sensors is the TP48, which mounts directly onto the transmitter via spare conduit entries or a tee fitting. Where these entries are not available or 3-wire devices are used, the compact design and simple installation of the SD Series makes it an ideal choice for transmitter protection. The SDs within the junction box should be installed as close as possible to the sensor or transmitter they are protecting, but no further than one meter away. A bond is required from the general mass of steelwork to the sensor or transmitter housing, using either a flat short braid or a cable at least 0.16 inch2 (4mm2) cross sectional area. In most instances, this bond is made automatically by fixing the metallic transmitter housing to the plant structure and ensures the voltage difference between the signal conductors and the transmitter housing is below the transmitter’s insulation rating. Please note that the transmitters or sensors are connected to the SD protected equipment terminals, not the field cables. 2-wire transmitters or sensors TO HOST CIRCUIT SD PROTECTED FIELD CIRCUIT 4-20mA transmitters - conventional and smart The SD16X, SD32X and SD55X are an excellent alternative if the TP48 is not an acceptable solution, either because of technical suitability or mounting difficulties. 1 4 4-20mA 2 5 6 3 Plant structure SD16X SD32X SD55X SPD DIN rail 2-wire transmitter or sensor 3-wire transmitters or sensors Vibration Sensors and 4-20mA loop process control systems generally require three wire connections when powered from an external source. This may be accomplished in one unit by using the SD32T3 3- terminal Surge Protection Device (SPD). Because the SD32T3 protects all three conductors within the same unit, higher protection is achieved because the SPD hybrid circuitry is common to all three wires. 4 1 2 Plant structure 24V 5 3 4-20mA 6 Common OV SD32T3 The SD07R3, SD16R3, SD32R3 and SD55R3 are also suitable for the protection of 3-wire pressure transducers on low power circuits. SPD DIN rail 3-wire transmitter or sensor 1 4-wire transmitters or sensors Flow meters, level detectors, etc. 4-wire systems such as level detectors require two SDs, one for the supply and the other for the transmitter output. Generally the voltages across the pairs are similar, so the recommended choice is a pair of SD16X, SD32X or SD55Xs. Dependent upon the supply voltage, AC powered transmitters should be protected with an SD150X for the supply inputs. 4 4-20mA 2 5 6 3 1 4 Supply voltage Plant structure 2 5 Supply OV 6 3 SD16X SD32X SD55X SPD DIN rail 4-wire transmitter or sensor 79 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — S D S e r i e s Communication systems protection High-speed data links between buildings or one part of a plant to another have become more common with the widespread use of smart transmitters and the increase in remote installations. The SD Series has an SPD suitable for all process I/O applications with a choice of low resistance units, high bandwidth and a variety of voltage ranges. Featuring an extremely high bandwidth, the SDR Series is designed to meet the requirements for high speed data links. Communication systems RS232, RS422, RS485 SD PROTECTED HOST CIRCUIT TP PROTECTED FIELD CIRCUIT The recommended choice for these applications is the SD16R or SD32R depending on the maximum driver signal. 4 TP48 1 5 2 6 3 RS232, RS422, RS485 SD PROTECTED HOST CIRCUIT PROTECTED FIELD CIRCUIT Bus powered systems 4 1 There are a variety of bus powered systems specially designed for the process industry. The ideal surge protection device for these systems is the SD32R, with a very high bandwidth and modest in-line resistance. 4 5 2 6 3 1 5 2 6 SD32R (no fuse) 3 SD32R (no fuse) TP48 4 5 6 1 2 3 SD32R (no fuse) Bus powered systems Table 1 Typical Applications Table 1 shows suitable SD devices for different applications. In some applications alternative devices may be used, for example, where lower in-line resistance or a higher voltage power supply is used. MTL Surge Technologies has operationally tested the recommended SD Series units with the representative highways listed. However, no formal approval for their use in these systems has been sought from the respective bodies. Application Allen Bradley Data Highway Plus Preferred Part No. Alternate Part No. SD16R Foundation Fieldbus 31.25kbits/s voltage mode SD32R 1.0/2.5 Mbits/s SD55R HART SD32X SD32, SD32R Honeywell DE SD32X SD32, SD32R LonWorks FFT-10 SD32R LPT-10 SD55R TP-78 SD07R IS78† SD32R Modbus & Modbus Plus (RS485) SD16R PROFIBUS DP PA (IEC 1158, 31.25 kbits/s) SD32R SD32R RS232 SD16 RS422 SD07R RS423 SD07R RS485 SD07R WorldRP (IEC 1158) SD32R 31.25 kbits/s voltage mode 1.0/2.5 Mbits/s SD55R 80 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com SD16X S u r g e P ro t e c t i o n D e v i c e s — S D S e r i e s Hazardous area applications Zone0/Zone1 The dangers from lightning induced sparking in Zone 0 are considered real enough to require preventative measures. IEC 60079-14 (1996-12) Electrical apparatus for explosive gas atmospheres Part 14: Electrical installations in hazardous areas (other than mines) stresses the importance of SPDs in hazardous areas. An outdoor installation where there is a high likelihood of both lightning induced transients and combustible gases requires the installation of SPDs to prevent possible ignition of the gases. Areas seen particularly at risk include flammable liquid storage tanks, effluent treatment plants, distillation columns in petrochemical works and gas pipelines. SPDs for transmitter protection should be installed in Zone 1, sufficiently close to the Zone 0 boundary to prevent high voltages entering Zone 0. The distance from the SPD to Zone 0 should be less than 36” where possible. In practice the SPD would normally be mounted on the transmitter or sensor housing which usually lies in Zone 1 and is very close to Zone 0. Because there is only a very small free volume, the SD series is suitable for mounting in flameproof or explosion proof enclosures. Zone 2 The SD series is suitable for protecting electrical circuits in Division 2, Zone 2 and can be used without affecting the safety aspects of the circuit. Non-incendive (low-current) circuits can be protected using any SD series unit mounted in either the safe or hazardous area, including those with the fuse disconnects facility. Non-arcing (high current) circuits can also be protected, however SPDs with the fuse disconnect facility may only be mounted in the safe area. For use in these circuits the units must be mounted in a suitable enclosure. In most cases the minimum requirements are IP54 and 7Nm resistance to impact. The SD series is self certified by MTL Surge Technologies as suitable for this purpose. The certification parameters for the SD**R, SD**R3 and SDRTD are: EEx ia IIC T4, Li = 0 li = 260mA for Ui up to 60V The power rating for each of the above is dependent on the table shown below. Pi = 1W (–30°C to +75°C) Pi = 1.2W (–30°C to +60°C) Pi = 1.3W (–30°C to +40°C) The SD** series are classified as simple apparatus and are intended for use in Zone 2 or safe areas only, because their fuses are not fully encapsulated. Installation Positioning The SDs should be mounted on the field wiring side to ensure that any surges entering from the field do not damage any intrinsically safe barriers or galvanic isolators in the system. The SDs and intrinisically safe interface should be mounted close to each other but on separate DIN-rails in order to maintain the required 1.97” (50mm) clearance between safe area and hazardous area terminals of the IS interface. SD series DIN rail IS barrier DIN rail Instrument Field cables Instrument earth Substation ground mat Certification Introducing surge protection into Intrinsically Safe (IS) circuits is trouble free as long as the current and power parameters are not exceeded. In the SD series, the SD**X, SD**R, SD**R3, SDRTD and SD**T3 all have ATEX certification for use in IS circuits located in Zones 0, 1 or 2. The certification parameters for the SD**X and SD**T3 are: EEx ia IIC T4, Li = 0.22mH li li li li = = = = 260mA for Ui up to 20V 175mA for Ui up to 26V 140mA for Ui up to 28V 65mA for Ui up to 60V Grounding The recommended grounding for field-mounted devices has been illustrated previously. The grounding at the control panel is more critical as there are usually a number of grounding systems, each with their own requirements.The grounding system illustrated here replaces the instrument 0V bond, the control system PSU bond and the IS ground with one single ground connection to meet all the design requirements and give the most effective protection against the effects of lightning induced surges. Marshalling cabinet System Connection Cable SPD Isolated instrument rail Isolated instrument rail Electrical earth Frame connection Floor void System earth To plant/neutral star point In all installations utilizing safety related apparatus, consideration should be given to protecting the system supply and any long communication cable. 81 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — S D S e r i e s Protection Full hybrid line to line Each line to screen/ground Max. discharge surge current (Imax) (8/20µs) 10kA (8/20μs) 6.5kA (SD150X and SD275X only) Max. discharge surge current (isn) 3kA (8/20μs) Lightning impulse current (Iimp) (10/350µs) 2.5kA 1.0kA (SD150X and SD275X only) Response time <1ns RTD resistance range (SDRTD) 10 to 1500Ω Degradation accuracy (SDRTD at 1mA) 0.1% (RTD resistance > 100) 0.1W (RTD resistance < 100) Ambient temperature –40°C to +80°C - working (-40°F to 176°F) –40°C to +80°C - storage (-40°F to 176°F) Humidity 5 to 95% RH (non-condensing) Category tested A2, B2, C1, C2, C3 Overstressed fault mode In=3kA 12kA 9kA (SD150X and SD275X only) Impulse durability (8/20µs) 10kA 6.5kA (SD150X and SD275X only) Terminals 2.5mm2 (12 AWG) Mounting T-section DIN-rail 35 x 7.5 or 35 x 15mm rail (1.38” x 0.3” x 0.6”) Weight 70g approximately (2.5oz) Case flammability UL94 V-2 AC durability 1Arms, 5T Service conditions 80kPa - 160kPa 5% - 95% RH EMC compliance To Generic Immunity Standards, EN 50082, part 2 for industrial environments R&TTE compliance EN 50082-2 : 1995 EN 41003 : 1999 EN 60950 : 1992 (not applicable to SD150X and SD275X) LVD compliance SD150X & SD275X EN 60950 : 1992 EN 61010 : 1995 SDPSTN EN 41003 : 1999 IEC compliance EN 61643-21:2001 Approvals Standard Certificate/File No. Approved for Product Canada, USA (CSA/C/US) Country (Authority) CSA C22.2 No. 0-M1991 CSA C22.2 No. 157-M1992 UL 913, 5th edition CSA C22.2 No. 142-M1987 CSA C22.2 No. 213-M1987 UL 508, 17th edition UL 1604, 3rd edition LR 103652-3 EEx ia Class 1, Groups A, B C and D, T4 Class 1, Div 2 Groups A,B,C, D T4 SD07,SD16,SD32,SD55, SD07X,SD16X,SD32X, SD55X,SD07R,SD16R, SD32R,SD55R,SDRDT, SD32T3,SD07R3,SD16R3, SD32R3,SD55R3 USA (UL) UL 497B Listed E220693 Isolated loop communication circuits SD07,SD16,SD32,SD55 SD07X,SD16X,SD32X SD55X,SD07R,SD16R SD32R,SD55R,SD07R3 SD16R3,SD32R3,SD55R3 SD32T3,SD55T3, SD07X3,SD16X3,SD32X3, SD55X3,SDRTD USA, Canada (UL) UL 1449 Recognized Component E217523 AC power protection SD150X,SD275X 0.28” +0.02” -0.0” +0.4mm -0.0mm 4 7.0mm 1 5 2 6 3 4.03” (102.1mm) 0.28” rail (7mm) 4.32” (109.6mm) 0.6” rail (16mm) All figures typical at 77°F (25°C) unless otherwise stated 3.99” (101.3mm) Specifications SD Series 3.9” (99mm) Ordering Data Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance W/line Max. leakage current μA Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/μs V Residual voltage @ isn V Bandwidth frequency fG Special feature Ordering Data Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance W/line Max. leakage current μA Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/μs V Residual voltage @ isn V Bandwidth frequency fG Special feature Part No. SD07 Part No. SD16 Part No. SD32 Part No. SD55 7 5 250 4.2 500 7.7 <12 16 11 250 4.2 5 17 <25 32 22 250 4.2 5 36 <45 55 38 250 4.2 5 62 <90 30 25 fuse disconnect 40 25 fuse disconnect 60 25 fuse disconnect 100 25 fuse disconnect Part No. SD07R Part No. SD16R Part No. SD32R Part No. SD55R 7 5 400 2.7 500 7.7 <12 16 11 400 4.7 5 17 <25 32 22 400 10 5 36 <45 55 38 400 10 5 62 <90 30 50 high Bandwidth 40 50 high Bandwidth 60 50 high Bandwidth 100 50 high Bandwidth 82 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — S D S e r i e s Ordering Data Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance W/line Max. leakage current μA Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/μs V Residual voltage @ isn V Bandwidth frequency fG Special feature Ordering Data Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance W/line Max. leakage current μA Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/μs V Residual voltage @ isn V Bandwidth frequency fG Special feature Ordering Data Technical Data Nominal voltage+(Un) Vdc Nominal voltage+(Un) Vac Nominal current (In) mA Series resistance W/line Max. leakage current μA Rated voltage (MCOV) Uc Voltage protection level (Up) @1kV/μs V Residual voltage @ isn V Bandwidth frequency fG Special feature Part No. SD07X Part No. SD16X Part No. SD32X Part No. SD55X 7 5 400 2.2 500 7.7 <12 16 11 400 2.2 5 17 <25 32 22 400 2.2 5 36 <45 55 38 400 2.2 5 62 <90 30 25 low resistance 40 25 low resistance 60 25 low resistance 100 25 low resistance Part No. SD32T3 Part No. SD07R3 Part No. SD16R3 Part No. SD32R3 Part No. SD55R3 32 22 400 2.2 5 36 <45 7 5 400 2.7 500 7.7 <12 16 11 400 4.7 5 17 <25 32 22 400 10 5 36 <45 55 38 400 10 5 62 <90 60 720 3 terminal 30 50 3 terminal 40 50 3 terminal 60 50 3 terminal 100 50 3 terminal Part No. SDRTD Part No. SDPSTN Part No. SD150X Part No. SD275X 1 0.75 >10 2.7 0.3 5 <12 162 114 550 4.7 5 175 <200 170 120 3A 0.1 250 ac rms; 170 ac 130 ac rms <400 339 240 3A 0.1 250 ac rms; 350 ac 275 ac rms <700 30 50 3-wire RTD 235 4 PSNT 450 high current 850 high current Mounting Accessories 0494920000 Rail Holder Grounding/Ground Rail Accessories 1010100000 Ground terminal, DIN rail mounted Accessories (Replacement) SDF25 Replacement fuse pack 250mA standard Preferred Alternate Application Part No. Part No. Application Allen Bradley Data Highway Plus Foundation Fieldbus 31.25kbits/s voltage mode 1.0/2.5 Mbits/s HART Honeywell DE LonWorks FFT-10 LPT-10 TP-78 IS78† Modbus & Modbus Plus (RS485) SD16R SD32, SD32R SD32, SD32R PROFIBUS DP PA (IEC 1158, 31.25 kbits/s) RS232 RS422 RS423 RS485 WorldRP (IEC 1158) 31.25 kbits/s voltage mode 1.0/2.5 Mbits/s SD32R SD55R SD32X SD32X SD32R SD55R SD07R SD32R SD16R Preferred Alternate Part No. Part No. SD32R SD32R SD16 SD07R SD07R SD07R SD32R SD16X SD55R 83 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — S L P S e r i e s Specifications SLP Series Approvals All figures typical at 77°F (25°C) unless otherwise stated Standard Certificate/File No. Approved for Product ATEX BS EN 60950:1992 BS EN 61000-6-2:1999 BS EN 61010-1:1993 ATEX0377X EEx N IIC T4 SLP07D, SLP16D, SLP32D USA (FM) Class Nos. 3600 (1998), 3610 (1999), 3611 (1999), 3615 (1989), 3810 incl. Supp 1 (1995-07 (1989-03), ANSI/NEMA 250 (1991), ISA-S12.0.01 (1999) 3011208 Intrinsically Safe: I/1/A-D, I/O/II C Non incendive: I/2/A-D, I/2/II C SLP07D, SLP16D, SLP32D Canada (FM) C22.2 No. 213, 142, 94, 157, 30 ANSI/NEMA 250 CAN/CSA-E79-0 CAN/CSA-E79-11 3025374 IS/I/1/ABCD I/0/Ex ia/IIC I/0/Ex ib/IIC NE/I/2/ABCD NE/I/2/IIC SLP07D, SLP16D, SLP32D Maximum surge current 20kA (8/20μs waveform) per line Leakage Current <1mA @ working voltage Maximum rated load current 1.50A Loop resistance 2 Ohm Capacitance Line - Line - 60pF Bandwidth -0.1db @9kHz - 37MHz -3dB @50MHz Response time <1ns Ambient temperature –40°C to +80°C (working) –40°F to +176°F (working) –40°C to +80°C (storage) –40°F to +176°F (storage) Humidity 5 to 95% RH (non-condensing) Country (Authority) Terminals 2.5mm2 (12 AWG) Electrical connections Plug/header screw terminal strip Mounting T-section DIN-rail (35 x 15mm rail) Weight 5oz (140g approximately) Case flammability UL94-V0 EMC compliance BS EN 60950:1992 BS EN 61000-6-2:1999 BS EN 61010-1:1993 Dimensions Connections Ordering Data Technical Data Nominal voltage Un Rated voltage (MCOV) Uc Nominal current In Nominal discharge current (8/20μs) isn Max discharge current (8/20μs) Imax Lightning impulse current (10/350μs) Iimp Residual voltage @ isn Up Voltage protection level @ 1kV/μs Up Bandwidth fG Capitance C Series resistance R Operating Temperature Range Category tested Overstressed fault mode in=3kA Impulse durability (8/20μs) Degree of protection AC durability Service conditions Part No. SLP07D Part No. SLP16D Part No. SLP32D 7V 8V 1.50A 3kA 20kA 2.5kA 10V <8V 50MHz 60pF 1.0 -40°C to +80°C A2, B2, C1, C2, C3, D1 22kA 10kA IP20 1Arms, 5T 80kPa - 160kPa 5% - 95% RH 16V 18V 1.50A 3kA 20kA 2.5kA 23V <18V 50MHz 60pF 1.0 -40°C to +80°C A2, B2, C1, C2, C3, D1 22kA 10kA IP20 1Arms, 5T 80kPa - 160kPa 5% - 95% RH 24V 32V 1.50A 3kA 20kA 2.5kA 40V <38V 50MHz 60pF 1.0 -40°C to +80°C A2, B2, C1, C2, C3, D1 22kA 10kA IP20 1Arms, 5T 80kPa - 160kPa 5% - 95% RH Installation 84 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — M A 1 5 S e r i e s Specifications MA15 Series MA15 Series Although industrial computers and PLCs are designed to be rugged, the extra protection provided by the DIN-rail mounting MA15 units is critical. Ideally suited for protecting panel mounted equipment and typically used in the controls section of a motor control center (MCC), the MA15 range provides surge and RFI protected power. With a unique ‘three-stage’ combination of protection elements, these units suppress conducted RFI and voltage surges. The circuit elements are: (1) surge clipping components to absorb transient surges that may otherwise damage equipment, (2) a filter to suppress noise in the system and, (3) ring suppression. Ring suppression prevents surges causing the filter to ‘ring’ (oscillate) under low load conditions – an effect that actually accentuates interference in most commercially available filters. Suitable for AC or DC application, MA15 units reduce both electromagnetic emissions and the susceptibility of the associated equipment to emissions from other sources. MA15 devices also offer installation flexibility. To protect circuits rated 15A or less, MA15 devices should be installed in series. To protect higher current circuits, simply install the MA15 in parallel. LED status indication is standard with the MA15 units. Thermal fusing is also incorporated into each 18kA rated device as an additional safety feature. MA15 modules also offer short circuit protection for added safety. Dimensions Maximum surge current: 18kA (8/20 μs) per mode Maximum leakage current: <0.3mA Maximum continuous operating current 15A series connection Unlimited Amps in parallel Maximum continuous operating voltage 25% above nominal Limiting voltage Let through voltage @ 500A ring 120V/140V versions 295V 240V/280V versions 356V @ 500A 8/20 µs 120V/140V versions 320V 240V/280V versions 800V @ 3kA 8/20 µs 120V/140V versions 396V 240V/280V versions 975V @ 10kA 8/20 µs 120V/140V versions 585V 240V/280V versions 1210V Maximum attenuation (typical): -55dB @ 100MHz Modes protected: L-N, L-G, N-G Ambient temperature limits –40°F to +185°F (working) –40°C to +85°C (working) Humidity 95% RH (non-condensing) Casing Polymide-PA, with G- or T-section (Top-hat) DIN-rail mounting foot Connectors Screw terminal Terminals 0.1 inch2 (2.5mm2 ) 12 AWG Installation Mounting G- or T-section (‘Top-hat’) or 1.4 inch (35mm) DIN rail Weight 3.53oz (100g) EMC compliance BS EN 60950 : 1992 BS EN 61000-6-2 : 1999 LED Indication Green LED on Protection present Green LED off Internal failure All figures typical at 77°F (25°C) unless otherwise stated Ordering Data Part No. MA15D1SI MA15D2SI AC 120V, 47-63Hz 240V, 47-63Hz DC 140V 280V The grounding of the surge protector and the protected equipment is very important and, if possible, should be accomplished as illustrated. Please note that the unit is marked Line and Load and it is important that the unit is installed with the Line side connected to the incoming power and the Load connected to the equipment to be protected. For parallel application however, the Line side is connected to the incoming power and the Load left unconnected. Approvals Standard Approved for Product No. United States Canada Country (Authority) UL 1449 Recognized Component AC Power Product MA15D1SI, MA15D2SI United States Canada UL 1449 Recognized Component UL 1604 Hazardous Locations Class I, Division 2 Groups A, B, C and D MA15D1SI, MA15D2SI { 85 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com S u r g e P ro t e c t i o n D e v i c e s — T P 4 8 S e r i e s The TP Series protection network consists of high-power, solid-state electronics and a gas-filled discharge tube capable of diverting 10kA impulses. The whole unit is encased in an ANSI 316 stainless steel housing, threaded for the common conduit entries used on process transmitters. Versions are available for 1/2” NPT, 20mm ISO, and G1/2” (BSP 1/2 inch) threaded entries. Approvals Country (Authority) Atex Directive 94/9/EC USA (FM) Specifications TP Series All figures typical at 77°F (25°C) unless otherwise stated Maximum surge current 10kA peak current (8/20μs waveform) Leakage current Less than 10μA at maximum working voltage Working voltage 48 VDC maximum Bandwidth 1MHz Resistance No resistance introduced into loop Ambient temperature limits -20°C to +80°C (working) -40°C to +80°C (storage) Humidity 5% to 95% RH (non-condensing) Electrical connections TP48 3 flying leads (line1, line 2 & ground) TP48 3 Wire 4 flying leads (+ve, -ve, signal & ground) TP48 4 Wire 5 flying leads (+ve, -ve, signal +ve, signal -ve, ground) Wire size 32/0.2 (1.0mm2, 18 AWG) Lead length 250mm (minimum) Casing ANSI 316 stainless steel hexagonal barstock, male thread Threads TP48-3-N & TP48-4-N 1/2” NPT TP48-3-I & TP48-4-1 20mm ISO (M20 x 1.5) TP48-3-G & TP48-4-G G 1/2” (BSP 1/2”) Weight 175g (6.2oz) Dimensions See Figure 1 EMC compliance To Generic Immunity Standards EN50082, part 2 for industrial environments Electrical safety EEx ia IIC T4, Ceq=O, Leq=0; the unit can be connected without further certification into any intrinsically safe loop with open circuit voltage <60V and input power <1.2W. EEx d IIC T4; the unit is apparatus-approved to flame proof (explosionproof) standards, and can be fitted into a similarly approved housing. Canada (FM) Global Standard BS EN 50021:1999 Certificate/File No. TML02ATEX0032X Class Nos. 3600 (1998), 3610 (1999), 3611 (1999), 3615 (1989), 3810 incl. Supp 1 (1995-07 (1989-03), ANSI/NEMA 250 (1991), ISA-S12.0.01 (1999) C22.2 No. 157 C22.2 No. 213 C22.2 No 142 C22.2 No. 94 C22.2 No. 30 3022293 IEC 60079-0:2004 IEC 60079-11:2006 3025374 IECEx BAS 07.0045X Approved for Ex n II T6 (-40°C<Tamb<+60°C) EEx n II T5 (-40°C<Tamb<+85°C) Intrinsically Safe: I, II, III/1/A-G, I/0/IIC Explosionproof: I/1/A-D Non incendive: I/2/A-D, I/2/IIC Dust ignition proof: II,III/1/EFG Special protection: II/2/FG Intrinsically Safe: I, II, II/1/A-G, I/O/IIC Explosionproof: I/1/A-D Nonincendive: I/2/A-D, I/2/IIC Dust ignition proof: II, III/1/EFG Special protection: II/2/FG Ex ia IIC T4/T5/T6 Ex tD A20 IP6X T85°C/T100°C/ T135°C Product TP48-X-Y-Z TP48-X-Y-Z TP48-X-Y-Z TP48-X-Y-NDI IEC 61241-0:2004 IEC 61241-1:2004 Key: X = 3 or 4 or blank, Y = N, I or G, Z = NDI Ordering Data Part No. TP48NNDI TP48INDI TP48GNDI TP483NNDI TP483INDI TP483GNDI TP484NNDI TP484INDI TP484GNDI Dimensions 1/2” NPT thread 20mm ISO thread G 1/2” (BSP 1/2 inch) 1/2” NPT thread 20mm ISO thread G 1/2” - BSP 1/2 inch 1/2” NPT thread 20mm ISO thread G 1/2” - BSP 1/2 inch Figure 1 The TP units are designed for mounting directly into an unused conduit entry on a process transmitter housing. Generally, two such entries are provided, one of which is used for the loop wiring. On the unused entry, the blanking plug or other closure device is removed and an appropriately threaded TP screwed into its place. The transmitter specification should provide information indicating the required thread type. TP units can be installed using thread adaptors if necessary, including certified adaptors in hazardous area applications. For applications where two conduit entries are not provided or where both are used for electrical connections, TP units can be housed in conventional conduit hub or junction boxes, provided access to the loop terminals is possible. Figure 2 shows connection details for 3 & 4 wire process transmitter. Figure 2 Certified Certified Certified Certified Certified Certified Certified Certified Certified SPD SPD SPD SPD SPD SPD SPD SPD SPD - 2.95” (75mm) 1.07” (27mm) 0.91” (23mm) 2.17” (55mm) Dimensions across flats 0.91” (23mm) Installation 86 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Lead length 9.85” (250mm) minimum DIN-Rail Receptacles These modules are intended for use within cabinets and enclosures as 120 VAC outlets for power tools, lights, computers or test equipment for troubleshooting. 5 Amp Simplex w/Circuit Breaker 15 Amp Simplex w/o Circuit Breaker • Compact and easily snaps onto 35mm DIN-rail • CSA, UL508A and cULus approved • Available with ground fault current interrupt (GFCI) or standard simplex and duplex outlets • Option for visual indication of power included with GFCI versions • Enclosed versions feature NEMA rated enclosure with UL94 VO flammability rating Schematic diagram Schematic diagram Technical data Input voltage Voltage 1120 VAC 120 VAC Current Wire Size (AWG) Stripping Length mm/in. Terminal Torque Mounting Width Length 5A max. 26 - 12 AWG (0.14 - 4.0mm2) 6mm 0.5-0.6 Nm TS32 or TS35 DIN-Rail 35mm/1.38 in. 70mm/2.76 in. 15A max. 26 - 12 AWG (0.14 - 4.0mm2) 6mm 0.5-0.6 Nm TS32 or TS35 DIN-Rail 35mm/1.38 in. 70mm/2.76 in. 58.5mm/2.30 in. 58.5mm/2.30 in. Height Ordering data Type Part No. Type Single outlet with circuit breaker 9915480001 (supplemental protector with manual reset via push button) Single outlet without circuit breaker r LR-229352, v E252394 r LR-229352, v E252394 Part No. 9915480000 Approvals Trip Curves 87 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com DIN-Rail Receptacles Dimensional Drawing 15 Amp Duplex 15 Amp GFCI 120 VAC nominal, 125 VAC max. 15A max. 50 - 60 Hz Withstands 2000V per UL498 10 kA 2 kA N/A 20 - 10 AWG (solid or stranded, copper only) 0.79Nm/7 lb.-in. Screw terminals, slotted 120 VAC nominal, 125 VAC max. 15A max. 50 - 60 Hz Withstands 1500V per UL498 10 kA 10 kA 5mA ±1mA 20 - 10 AWG (solid or stranded, copper only) 0.79Nm/7 lb.-in. Screw terminals, slotted -25°C to 60°C -35°C to 80°C -25°C to 60°C -35°C to 80°C PBT/polycarbonate blend, UL94 rating V0 @ .63mm Polyamide 6/6 30% GF, UL94 rating V0 @ .63mm Stainless Steel TS35 DIN-Rail or direct panel mount 74.1mm/2.9 in. 123.6mm/4.9 in. 61.5mm/2.4 in. PBT/polycarbonate blend, UL94 rating V0 @ .63mm Polyamide 6/6 30% GF, UL94 rating V0 @ .63mm Stainless Steel TS35 DIN-Rail or direct panel mount 74.1mm/2.9 in. 123.6mm/4.9 in. 61.5mm/2.4 in. Type DRAC DP 15 Type DRAC GF 15 Technical data Voltage Current Operating Frequency Dielectric Voltage Short-Circuit Current Rating (SCCR) Current Interrupting Trip Level Termination Wire Size Terminal Torque Terminations Temperature: Operating Storage Material Listing Enclosure Cover, Flammibility Enclosure Base, Flammibility Spring Mounting Width Length Height Ordering data Part No. 6720005421 Approvals/Certifications Enclosure Type Description cULus Listed to UL508A and C22.2 No. 14 File E223801 NEMA WD6, 5-15R Description cULus Listed to UL508A and C22.2 No. 14 File E223801 NEMA WD6, 5-15R 88 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Part No. 6720005422 DIN-Rail Receptacles 15 Amp Duplex w/LED Dimensional Drawing This new DIN-rail mountable duplex receptacle makes adding a 120V maintenance AC outlet to control cabinets quick and easy. It mounts on standard 35mm DIN-rail and requires just 42mm of rail space. An LED indicates that 120V is applied to the module. The terminations accept slotted or Phillips screwdrivers. The mounting foot includes a latching lock – slide it open, mount the module on the DIN-rail and slide the lock closed. • requires just 42mm of DIN-rail • includes power status LED • latching mounting foot makes installation and removal from DIN-rail easy • CSA certified and cURus recognized Technical data Voltage Current Wire Size (AWG) Stripping Length mm/in. Terminations Terminal Torque Mounting Width Length Height 120 VAC nominal 15A max. 14-12 AWG (Solid or stranded, copper only) 8.8-11 / 0.347-0.433 Screw terminals, slotted or Phillips “L”:line “W”:neutral “G”:ground 0.5Nm/4.4 in-lb TS35 DIN-Rail 42mm/1.65 in. 99mm/3.90 in. 51mm/2.01 in. Ordering data Type DUPLEX 120VAC OUTLET W/LED Part No. 6720005430 Approvals/Certifications Description CSA certified, file 251163, Project 2345434, according to C22.2 No. 42 cURus recognized, file E340886, according to UL498 and C22.2 No. 182.3 89 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com DIN-Rail Receptacles Dimensional Drawing 20 Amp Duplex 20 Amp GFCI Technical data Voltage Current Operating Frequency Dielectric Voltage Short-Circuit Current Rating (SCCR) Current Interrupting Trip Level Termination Wire Size Terminal Torque Terminations Temperature: Operating Storage Material Listing Enclosure Cover, Flammibility Enclosure Base, Flammibility Spring Mounting Width Length Height 120 VAC nominal, 125 VAC max. 20A max. 50 - 60 Hz Withstands 2000V per UL498 120 VAC nominal, 125 VAC max. 20A max. 50 - 60 Hz Withstands 1500V per UL498 10 kA 2 kA N/A 20 - 10 AWG (solid or stranded, copper only) 0.79Nm/7 lb.-in. Screw terminals, slotted 10 kA 10 kA 5mA ±1mA 20 - 10 AWG (solid or stranded, copper only) 0.79Nm/7 lb.-in. Screw terminals, slotted -25°C to 60°C -35°C to 80°C -25°C to 60°C -35°C to 80°C PBT/polycarbonate blend, UL94 rating V0 @ .63mm Polyamide 6/6 30% GF, UL94 rating V0 @ .63mm Stainless Steel TS35 DIN-Rail or direct panel mount 74.1mm/2.9 in. 123.6mm/4.9 in. 61.5mm/2.4 in. PBT/polycarbonate blend, UL94 rating V0 @ .63mm Polyamide 6/6 30% GF, UL94 rating V0 @ .63mm Stainless Steel TS35 DIN-Rail or direct panel mount 74.1mm/2.9 in. 123.6mm/4.9 in. 61.5mm/2.4 in. Type DRAC DP 20 Type DRAC GF 20 Ordering data Part No. 6720005420 Approvals/Certifications Enclosure Type Description cULus Listed to UL508A and C22.2 No. 14 File E223801 NEMA WD6, 5-20R Description cULus Listed to UL508A and C22.2 No. 14 File E223801 NEMA WD6, 5-20R 90 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Part No. 6720005423 Notes 91 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Notes 92 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com Singapore Slovakia Slovenia South Africa South Korea Spain Sweden Switzerland Syria Taiwan Thailand Turkey UAE Ukraine United Kingdom Uruguay USA Venezuela Vietnam Yemen Weidmuller is the leading manufacturer of components for electrical connection technology to transmit energy, signals and data. The Weidmuller product portfolio ranges from terminal blocks, PCB connectors and terminals, protected ­components, Industrial Ethernet components, I/O components and relay sockets to power supplies and overvoltage protection ­modules suitable for all applications. Assemble Services, marking solutions with a variety of tools and software systems, round off the range. As an OEM supplier, the company sets global standards in the field of electrical connection technology. Power Delivery and Protection Solutions Catalog Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email:info1@weidmuller.ca Website:www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email:clientes@weidmuller.com.mx Website:www.weidmuller.com.mx Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email:info@weidmuller.com Website:www.weidmuller.com 010/11 • XM • LIT1291730000 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com 11 Catalog Iran Ireland Israel Italy Japan Jordan Kazakhstan Kuwait Latvia Lebanon Lithuania Luxembourg Macedonia Malaysia Malta Mexico Montenegro Netherlands New Zealand Norway Oman Paraguay Peru Philippines Poland Portugal Qatar Romania Russia Saudi Arabia Serbia 11 Power Delivery and Protection Solutions Argentina Australia Austria Azerbaijan Bahrain Belarus Belgium BosniaHerzegovina Brazil Bulgaria Canada Chile China Colombia Costa Rica Croatia Czech Republic Denmark Ecuador Egypt Estonia Finland France Germany Greece Hong Kong Hungary Iceland India Indonesia CATALOG www.weidmuller.com