POWERFLEX® Type SHD-GC 2000 Volt. Tinned Copper Conductors EPR Insulation. Tinned Copper Braid Shield. Integral Fill Inner Jacket. Extra Heavy Duty CPE Jacket. 4 AWG-500 kcmil. –50° C to 90° C APPLICATIONS Southwire’s Powerflex Type SHD-GC cables are designed for use with mobile, reeling or stationary mining equipment, continuous mining machines or longwall loading machines, blast hole drillers, heavy duty trailing cable where maximum protection is required. Also for medium and high voltage use on shovels, draglines, dredges, and cranes. This cable is also suitable for high voltage distribution in mines and tunnels where more flexibility is desired, especially in vertical drops. Powerflex SHD-GC is also an excellent choice for Marine ship to shore power supplies as it is designed for the harshest conditions and environments. SPECIFICATIONS Southwire’s Powerflex Type SHD-GC cables comply with: ASTM B-33 and B-172 MSHA P-122 and Pennsylvania DER (P-122-53) accepted UL CSA ICEA S-75-381/ NEMA WC-58 CONSTRUCTION Southwire’s Powerflex Type SHD-GC cables have soft drawn, annealed, tinned copper conductors covered by black flame resistant EPR that provides ozone, oil, water, solvent corrosive and abrasion resistance. A Mylar separator is applied under the insulation to aid in stripping. The insulation shield consist of a tinned 5-wire copper braid (60% coverage) duplexed with a nylon denier colored tracer (40% coverage). The assembly includes two tinned copper bare ground wires that maintain contact with the insulation shields and one yellow tinned copper HD EPR insulated ground check for monitoring purposes. A served woven nylon polyester binder is applied over the cable for added core stability. The outer jacket is a dual layer, black, flame resistant, thermosetting CPE rubber that provides excellent resistance to UV, oil, water, solvents, corrosives, cuts, tears and abrasions. A woven nylon polyester binder is served between the two jackets to provide added dynamic and mechanical integrity. POWERFLEX Type SHD-GC Power Conductors Grounding Conductors Size Strands Insulation Number Size Strands Ground Check Size Strands Weight per Approx. 1000’ O.D. Ampacity + (lbs) 3 Conductor Cable 4 259 .060” 2 8 168 8 168 1.40” 1347 114 2 308 .060” 2 7 133 8 168 1.59” 1895 152 1/0 273 .080” 2 5 133 6 273 1.86” 2785 205 2/0 324 .080” 2 4 259 6 273 2” 3190 237 3/0 418 .080” 2 3 259 6 273 2.13” 3636 274 4/0 532 .080” 2 2 308 6 273 2.31” 4684 316 250 608 .095” 2 1 385 6 273 2.51” 5750 352 350 855 .095” 2 1/0 273 6 273 2.81” 6817 433 500 1221 .095” 2 3/0 418 6 273 3.19” 9998 536 +Ampacities (per conductor) are based on 40° C ambient temperature in air, 90° C conductor temperature per ICEA S-75-381, Appendix H-1