XS Fan Module The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU Supply/Extract Units Installation and Maintenance E Introduction General The Nuaire XS Fan Module is available in 6, 9 and 12 inch impeller sizes suitable for supply or extract. An internal grille assembly is included for use if required. Ensure adequate air replacement for the fan and any fuel burning appliance in the room. The external rotor motor makes for simple removal of the push-on impeller for easy cleaning. The fan is IP24 splash proof approved with the motor rated at IP44. Fig 1 Fan module and internal grille. Removing the Grille All external components are made in soft grey colours from ultra violet stable ABS material so they will blend with most decors and will not fade in sunlight. The Fan Module is supplied complete with an inlet grille. To remove the grille, remove the two lower grille fixings. The grille can now be lifted upwards to clear the top lip retainer and removed.] Re-fitting the grille is the reverse of this procedure. Fan Module Internal grille Coding for Fan Modules Description 6 inch Fan Module 9 inch Fan Module 12 inch Fan Module 6 inch Refurb Kit 9 inch Refurb Kit 12 inch Refurb Kit Code XS6 XS9 XS12 XS6RE XS9RE XS12RE General Applications Switching The Nuaire XS Fan Module can be used as a direct replacement spare for any of the XS Fan Installation Kits available from Nuaire. Remember to specify fan size 6, 9 or 12inch. Operated via a separately wired 3 amp fused spur (by others) or operated via the optional XS-MFC remote controller allowing supply or extract, variable speed and automatic or manual switching of several fans if desired. The XS Fan Installation Kits available are as follows: XS Window Fan Kit XS Wall Fan Kit XS Ceiling Fan Kit XS Roof Fan Kit Sensors Sensors are available as remote units or integral ‘plug in’ units. They are able to control multiple fans, depending on sensor and fan types. Integral sensors are quick and easy to install and are aesthetically pleasing, whilst remote sensors give the benefit of location close to the pollutant source. Remote sensors can be fitted with an optional security strap to prevent unwanted tampering. Other applications 1). In Line installation (using Duct Kit from Nuaire Code: XS-IDK) See page 7 for details. 2). Plate Installation fixing the Fan Module face direct to a wall. 3). Retro fit into an existing wall aperture/outlet louvre. Page 5. Dimensions of Fan Module (mm) Fig 2. A C Fixing Holes XS6 Fan Module XS9 Fan Module XS12 Fan Module B FRONT VIEW (Leaflet 671050) (Leaflet 671051) (Leaflet 671052) (Leaflet 671053) A 269 342 420 B 272 342 420 C 140 150 170 SIDE VIEW Nuaire Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk 1 Leaflet Number 671067 January 2012 Installation and Maintenance XS Fan Module Electrical wiring instructions Electrical work should be undertaken by a qualified electrician in accordance with the wiring regulations. 1 2 Release the electrical panel from the fan plate. Remove the terminal cover. 3 4 Clamp the cable and complete the connections. Refit terminal cover before replacing the electrical panel. Wiring Isolation - Before commencing work make sure that the unit is electrically isolated from the mains supply. 2 Leaflet Number 671067 January 2012 Installation and Maintenance XS Fan Module XS6 Consumption and weight Electrical Wiring cont. Input Power Watts Model Max. Weight kg Economy XS6 supply + extract 38 Note figures are for extract only. 20 4.1 Electrical Specification 230V ~ 50Hz Class I. Motor thermally protected by overload device. Cable: 1mm max. or min. Fuse: 3 amp (if fan is supplied from a 5A lighting circuit, no local fuse is required). XS9 Consumption and weight Input Power Watts Model Max. XS9 supply + extract Weight kg Economy 50 37 5.7 Note figures are for extract only Electrical Specification 230V ~ 50Hz Class I. Motor thermally protected by overload device. Cable: 1mm max. or min. Fuse: 3 amp (if fan is supplied from a 5A lighting circuit, no local fuse is required). XS12 Consumption and weight Model Input Power Watts Weight kg Max. Economy XS12 supply + extract 100 Note figures are for extract only 70 8.6 Electrical Specification 230V ~ 50Hz Class I. Motor thermally protected by overload device. Cable: 1mm max. or min. Fuse: 3 amp (if fan is supplied from a 5A lighting circuit, no local fuse is required). (Shutter Operation XS fans) There will be a short delay on startup and shutdown of approximately 40 seconds. This is normal. 3 Leaflet Number 671067 January 2012 Installation and Maintenance XS Fan Module Fitting Remote Controller XS-MFC or Remote Sensors (optional) 1 The XS-MFC Multi Fan Control provides supply or extract, variable speed and automatic or manual switching of several fans if desired, (see note below). The control is best mounted approx 1.5m above the floor. Remote Sensors are available for Humidity, Air Quality and Passive Infra Red control. Remote Sensors should be positioned at least 1.5m above the floor and away from direct heat sources e.g. radiators. Note: Up to 5 fans (size 6 / 9 inch) can be controlled by one XS-MFC. Up to 3 fans (size 12 inch) can be controlled by one XS-MFC. Do not mix different fan sizes on the same controller. Lift up panel and remove two screws to dismantle unit. 2 3 1.5m Spot through backplate box and drill and plug the wall. Push out backplate box cable entry using a screwdriver. 4 5 200mm Fix backplate box to the prepared wall. Feed approx. 200mm of supply cable into the box 6 7 Connect the end of the cable into the control block. Fit the control into the backplate box and secure. Test the installation. 4 Leaflet Number 671067 January 2012 Installation and Maintenance XS Fan Module Fitting Integral Sensors (optional) 1 Note: Before following the pictorial sequence shown- first remove the fans front cover grille (2 screws). Release the four main corner screws and lift out the motor/fan plate assembly. Remove the electrical cover plate opposite the sensor plate. Follow the pictorial sequence on this page. Unscrew the module plate from motor plate assy. 2 3 Remove the module plate. Lift out the sensor module wiring connector. 4 5 Plug the connector into the required sensor module. Screw the sensor module into position. Typical Application This shows an XS Fan Module being retro fitted into an existing wall aperture. The two internal wall battens are used to support the fan and should be arranged to match the fan fixing centres as listed in the table. XS6 XS9 XS12 X 237 310 390 Y 8 8 8 5 Leaflet Number 671067 January 2012 Installation and Maintenance XS Fan Module Refurbishment Installation Complete Kits XS12RE, XS9RE and XS6RE Replacing existing Nuaire XS Fans The fan is fixed as the previous fan into the existing channels on the wall liner. The picture frame can be used if desired, however the metal brackets are not required. Replacing existing T-Series Fans The brackets supplied with the kit can be aligned with the screw fixing holes of the previous fan. This then positions the receiving nut on the bracket in the correct location to allow fixing of the Nuaire refurbishment fan. Wiring details – T-Series Fans A Nuaire XS fan can be used to replace a Vent Axia ‘T’ Series fan, retaining the original controller, providing the controller is of the ‘Ecotronic 130’, ‘Rangemaster’ or ‘T’ Series Controller type. This arrangement will give the following operating features: ■ ■ ■ ■ ■ Adjustable speed Adjustable minimum speed Extract/intake Fan off – shutter open Fan off – shutter closed. Limitations are: Control of single fan only Integral sensors not possible Automatic ECO setting not available ■ ■ ■ This arrangement will give the following operating features: ■ ■ ■ Single speed Extract/intake On/off. Limitations are: ■ ■ ■ Control of single fan only Integral sensors not possible Automatic ECO setting not available Fans should be installed in line with the IEE wiring regulations. 6 Leaflet Number 671067 January 2012 Installation and Maintenance XS Fan Module Dimensions (mm) In Duct Kit Ancillaries In Duct Kit For use in In Duct applications when using flexible ducting. Comprising of one In Duct Kit. Manufactured from HIPS. The Fan is mounted within the two halves of the housing and the ducting is connected both sides. Order Code: XS-IDK6 Order Code: XS-IDK9 Order Code: XS-IDK12 For use with 6 inch fans. For use with 9 inch fans. For use with 12 inch fans. A B C D E XS-IDK6 268 268 197 240 25 XS-IDK-9 348 348 247 250 25 XS-IDK12 420 420 347 268 25 Maintenance Terms Periodically, at least once a year, or more frequently in case of heavy use, remove the dirt and encrustation from the grille(s) fan impeller and motor casing. Ensure the impeller is not cracked or deformed and is able to rotate freely and without oscillation. Do not use any solvents to clean this product. This warranty applies to units installed and used in the United Kingdom. The equipment will be repaired or replaced at Nuaire’s cost provided that the appliance: 1. Has been installed and used in accordance with the fitting and wiring instructions supplied with each unit. 2. Has not been connected to an unsuitable electrical supply. (The correct supply voltage is shown on the appliance rating label attached to the unit). Replacement of Parts As a manufacturer Nuaire is aware that time is important. In the event of a breakdown of this equipment, it should be adequately packaged and returned to Nuaire. IMPORTANT! Please telephone Nuaire before posting your unit. We will give you a returns number to identify your package. We will endeavour to repair or replace it within five working days of receipt. See our warranty terms. 3. Has not been modified or repaired by persons not authorised by Nuaire. 4. A unit returned to Nuaire should be suitably protectively packaged and clearly marked with the ‘returns number’ obtained from Nuaire prior to posting. Warranty Service Enquiries The 3 year warranty starts from the day of delivery and includes parts and labour for the first year. The remaining period covers replacement parts only. This warranty is conditional on planned maintenance being undertaken. Nuaire can assist you in all aspects of service. Our service department will be happy to provide any assistance required, initially by telephone and If necessary arrange for an engineer to call within 48 hours if possible. Telephone 029 2085 8585 Fax 029 2085 8586 Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. 7 Leaflet Number 671067 January 2012 Installation and Maintenance XS Fan Module Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 029 2088 5911 F: 029 2088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk 8 Leaflet Number 671067 January 2012