INSTALLATION INSTRUCTIONS IC LED Housings - Air Tight - Chicago Plenum (optional) TO BE USED IN INSULATED MATERIALS - SUITABLE FOR DAMP LOCATION LEU-ICLDLD1, LEU-ICLDLD2, LEU-ICLDLE1, LEU-ICLDLE2 LEU-ICLDLD1P, LEU-ICLDLD2P, LEU-ICLDLE1P, LEU-ICLDLE2P 1. SHUT OFF ELECTRICAL SUPPLY AT SOURCE. 2. Remove the can from the « IC » box by unscrewing the two screws that hold it in the box and reserve it with the screws for installation at STEP 10. 3. Locate position of mounting frames and install before the gypsum board. Fasten the mounting frame to the wood joist with the adjustable mounting bars (10’’ to 24,5’’). To shorten the bars to 10’’, remove bars and cut off at the knotch (See adjustable mounting bars detail view). 4. Diagram 0-10V dimmer (D1 - D2) Line (Black) Once the correct bar length is known, fold down and press tabs to lock the plate onto the mounting bars. Neutral (White) +10V Out (Yellow) Light Fixture Ground (Green) Dim + (Purple) Dim - (Gray) 1.1. 1. Joist Mounting Bar 7. Install the ceiling material and locate the center of fixture. 8. Cut a hole to a diameter of: Ø 3-5/8’’ (92 mm) 9. Connect the housing wires to the can wires. Press down and fold tabs Part 1 Adjustable bars detail Cutting Mark The sides are bridged to avoid separation after shortening on «Cutting Mark». Part 2 Cutting Mark If Part 2 needs to be shortened, both Parts will be held in place by «claws» on the IC Box. 5. Bring the electrical wiring to the housing junction box as per applicable local electrical codes. 6. Open the junction box and connect the wires based on diagrams below. Close the junction box. Diagram ELV dimmer (E1 - E2) 10. Insert can in the housing and fix it with the two adjustment screws. 1 3/4" adjusting slot to allow up to 1 1/2" thickness of gypsum board. Screws Spring Adjustable can 11. Install the trim. Connect the male and female connectors. Push connected wires in the pot then push the trim in the can. Line (E1 Brown / E2 Black) Neutral (E1 Blue / E2 White) Light Fixture A) Male connector B) Female connector Ground (Green) C) Trim Please keep these installation instructions for future maintenance. CAUTION The use of another company’s products or components in conjunction with this product may not be covered by UL approvals, and could be hazardous. Such use automatically voids all warranties and responsibility for any problems that may result from such use. WARNING SHOCK AND FIRE HAZARD Most dwellings built before 1985 have supply wires rated 60°C. Consult a qualified electrician before installing. Please visit the Website to see the list of compatible dimmers or for more details. AIR TIGHT ASTM Test #E283 11 Mayfield Avenue Edison, NJ 08837 t 732.225.0010 f 732.225.0250 www.leucosusa.com EL638 (Rev. C) 103714 2016-04