Brochure - IronGate Data Centers

advertisement
Protection is Central.
Twin Cities East Data Center
House your data in a building constructed for only one express purpose – protect the information inside. Twin Cities East Data
Center is nothing less than a concrete bunker protected by earthen berms. The position it holds makes it defiant against flood,
storm, attack, and prying eyes. With redundancy built into both security and infrastructure support, chances are your data will
outlast everything else. While exceedingly protected, the 85,000 square foot facility also provides the highest level of flexibility
anywhere: build exactly what you need and we will keep it safe.
Amenities Overview
Facility
• 85,000 sq ft Facility
• Purpose-built, bunkered,
single-level building with high
wind-rating
• 14’ to 28’ clear height
Loading
• Two (2) loading docks with
staging & storage areas
Other
• Energy-efficient ‘follow-me’
lighting available in
dedicated suites
• Potential for Minnesota Data
Center Sales Tax Exemption
(on software, hardware,
power, etc)
• Priority diesel fuel
delivery contracts
Management
• On-site management &
engineers
Amenities
• Shared conference center
• Shared kitchen & break room
• Dedicated office space
available
• Shared office space available
• Showers
www.irongatedatacenters.com
Phone: (612) 252-9893
Headquarters: AT&T Tower, 901 Marquette Avenue,
Suite 2820, Minneapolis, MN
Protection is Central.
Twin Cities East Data Center (cont.)
Power
Electrical
• N+1 or 2N topology
• 50 to 250 watts per sq.ft. (2 to 15 kW per rack averages)
Cooling
• N+1 of 2N topology
• Customer option of:
• In-row/overhead + containment
• CRAC (2’ to 3’ raised floor)
• Kyoto
• Custom
Fire Protection
• Dedicated Suite customer option of:
• Wet-pipe
• VESDA
• Pre-action
• Gaseous
Sub #1
Sub #2
Concurrently-maintained
Available for 500+kW Customer
substation
Up to 65 MW (medium voltage
w/ on-site transforming)
Up to 13 MW (medium voltage
w/ on-site transforming)
Utility paralleling
Utility paralleling
Self-healing grid
Connectivity
• Carrier-neutral
• Two (2) meet-me rooms
• Abundance of dark fiber available
• Diverse site & building entry
www.irongatedatacenters.com
Phone: (612) 252-9893
Headquarters: AT&T Tower, 901 Marquette Avenue,
Suite 2820, Minneapolis, MN
Protection is Central.
Twin Cities East Data Center (cont.)
Security Implements
1. Military-grade vehicle crash barriers
and gates
2. Entry man-traps with advanced sensory
technologies
3. Three (3) zones of man-containment
4. 24×7 manned security
5. Bullet-resistant glass throughout
6. Video surveillance throughout buildings
& site with on-site and
off-site monitoring
7. Advanced sensory-surveillance
technologies throughout
8. Local law enforcement and SWAT team
coordination
9. Biometrics + keycard + code
access requirements
7
C
9
6
4
6
2
5
6
1
Disaster Avoidance
www.irongatedatacenters.com
• Not in 500 year floodplain
• Not in proximity to railroads, chemical plants, airport
takeoff/landing zones
• Earth-bermed & bunkered for wind/tornado mitigation
A
Phone: (612) 252-9893
Headquarters: AT&T Tower, 901 Marquette Avenue,
Suite 2820, Minneapolis, MN
Protection is Central.
Twin Cities East Data Center (cont.)
Availabilities
• Single cabinet to multi-megawatt deployments
• 50 to 250 watts per sq.ft.
• N+1 or 2N electrical
• N+1 or 2N mechanical
Shared Space & Shared Infrastructure
• Concurrently-maintainable electrical and mechanical systems
• 150 sq ft to 500 sq ft Cages
• Lockable Racks
• Half and Quarter Racks
Occupancy Lead Times
• Dedicated space + dedicated infrastructure = 90 days for signing
• Dedicated space + shared infrastructure =100 days from signing
• Shared space + shared infrastructure = 30 days from signing
Suite
Space
Power
Support
A (LEASED)
5000 sq ft
1.25 MW of Power
2N Electrical & N+1 Mechanical Systems
B
Up to 35000
sq ft
Up to 9 MW of power
Build-to-Suit Electrical & Mechanical Systems
C
7500 sq ft
Up to 2 MW of Power
Build-to-Suit Electrical & Mechanical Systems
D
5000 sq ft
Up to 1.5 MW of Power
Build-to-Suit Electrical & Mechanical Systems
E
2000 sq ft
Up to 500kW of Power
Build-to-Suit Electrical & Mechanical Systems
F
1000 sq ft
Up to 250kW of Power
Build-to-Suit Electrical & Mechanical Systems
G
1000 sq ft
Up to 250kW of Power
Build-to-Suit Electrical & Mechanical Systems
www.irongatedatacenters.com
Phone: (612) 252-9893
Headquarters: AT&T Tower, 901 Marquette Avenue,
Suite 2820, Minneapolis, MN
Protection is Central.
Twin Cities West Data Center
With redundancy built into both security and infrastructure support, chances are
your data will outlast everything else. While exceedingly protected, the 30,000
square foot facility also provides the highest level of flexibility anywhere: build
exactly what you need and we will keep it safe.
Amenities Overview
Facility
• 30,000 sq ft of data center
space
• 14 foot clear height in data
center
• Concrete construction
in data center
Management
• On-site management &
engineers
Amenities
• Office space and turn-key
disaster recovery office space
available
Loading
• Two (2) loading docks with
staging & storage areas
Power & Connectivity
Electrical
• Utility territory of Xcel Energy
• 4 MW available
• Scalable, modular design up to
250 watts per square foot
Fiber
• Carrier-neutral
• Dark fiber available
• Diverse site & building entry
Cooling
• N+1 of 2N topology
Security
www.irongatedatacenters.com
Disaster Avoidance
• Not within the 200 year
flood plain
• Not in proximity of
railroad tracks
• Not under take-off, landing or
flight pattern of any airport
• Not in proximity to any
chemical plants or prospective
terrorist targets
Security Implements
• Concrete construction
in data center
• Subterranean data center
Phone: (612) 252-9893
Headquarters: AT&T Tower, 901 Marquette Avenue,
Suite 2820, Minneapolis, MN
Protection is Central.
Twin Cities East Data Center (cont.)
Availabilities
• Independently demised space for each tenant and shared space available
• Exclusive infrastructure and shared infrastructure available
Shared Space & Shared Infrastructure
• Concurrently-maintainable electrical and mechanical systems
• Availabilities
• 150 sq ft to2,000 sq ft Cages
• Lockable Racks
• Half and Quarter Racks
Occupancy Lead Times
• Dedicated space + dedicated infrastructure = 90 days for signing
• Dedicated space + shared infrastructure =100 days from signing
• Shared space + shared infrastructure = 30 days from signing
Suite
Space
Power
Support
SUITE 100
1000 sq ft
Up to 250kW of Power
Build-to-Suit Electrical & Mechanical Systems
SUITE 101
2500 sq ft
Up to 250kW of power
Build-to-Suit Electrical & Mechanical Systems
SUITE 102
5000 sq ft
Up to 250kW of power
Build-to-Suit Electrical & Mechanical Systems
www.irongatedatacenters.com
Phone: (612) 252-9893
Headquarters: AT&T Tower, 901 Marquette Avenue,
Suite 2820, Minneapolis, MN
Download