catalogue

advertisement
CATALOGUE
Data Center Racks
Power Management
Co-Location Racks
KVM Solutions
IP Cabinets
Switching Solutions
EV Cabinets
Environmental Monitoring
Summer Edition 2011
Contents
Introduction
1
WallMount Boxes
2
Server Racking Solutions
4
IP Rated Racking Solutions
13
Co-Location Cabinets
16
ETSI Cabinets
20
Custom Racking Solutions
21
Rack Accessories
22
Adler Power Solutions®
23
The IP-EV Bio Unit Closure
26
Environmental Racking – EV Rack®
EV-Rack® Anatomy
28
EV-Rack®Configuration
29
EV-Rack®AccessControl–Suprema
30
EV-Rack®ThermalManagement–Panasonic
31
EV-Rack®FireSuppression–PanelSafe®
32
EV-Rack Monitoring–Geist
33
Data Center KVM Solutions – ATEN
DataCenterKVMSolutionGuide
34
KVMSolutions–ATEN
36
Geist® Monitoring Solution
AdleRac®In-LinePowerMonitoringSolutions
41
AdleRac Local&RemoteCurrentMonitoring
42
AdleRac BasicLocalPower&CurrentMonitoring
43
RacSense VariableSpeedFanController
44
®
®
®
®
Power Management – Server Technology ServerTechnology®PowerDistributionUnits
46
Network Switches
Cisco®Switches
55
Cisco®MobilityExpress
58
HP ProCurve PoE and UC Switch Selection Guide
59
ANS – Adler Networking Solutions®
62
FibreNet® Fibre Optic Cables
63
FibreNet® Connectors and Adaptors
64
Proudly South African Certification
65
SABS Certification
66
Glossary
68
Summer Edition 2011
Introduction
DESIGNERS, MANUFACTURERS AND SUPPLIERS OF DATA CENTER RACKING SOLUTIONS
AdleRac®isspecialisedincabinetsandenclosuresforITinfrastructureintheDataCentreandTelecommarkets.
AdleRac®cabinetsolutionsareidealforservers,networkcomponentsandcablinginfrastructure.Thecabinetsare
modular,sotheycanbeadaptedeasilytochanginghardwareconfigurations.
With over 18 years of industry experience, AdleRac® delivers a structural contribution of superior quality for
tomorrow’sITinfrastructure.
AdleRac®hashelditsSABS ISO 9001:2008accreditationforthelast16yearsandworksaccordingtothese
standardstodeliverasuperiorlevelofquality.Thisensuresthatyouhaveafullyintegratedcabinetsolutionfor
yourITinfrastructureatyourdisposalatalltimes,builtaccordingtothelatestspecificationsoftheTIA-310-D
standards.
AdleRac®willalwaysprovideafullyintegratedcabinetsolutionforyourITinfrastructurewhichisdurableandof
highqualitythatguaranteesoptimalefficiencyandsustainedperformance
AdleRac®playsaleadingroleasaProudlySouthAfricanmanufactureroffuture-proofcabinetsolutions.
1
WallMount Boxes
Key Features
Glassdoor
Depthadjustable
punchedprofiles
Fanknock-out
• •
•
•
•
•
•
•
19”wallmountingbox
Fabricatedfromsheetmetal
Epoxypowdercoated
Adjustable(fordepth)punchedprofiles
Convenientlypositionedfancut-outs
Cableentrycut-outs(100mmx40mm)topandbottom
Standardwithlockableglassdoor
AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Options
• 100mmswingframecollar(foraccesstorearofbox)
• 200mmswingframecollar(foraccesstorearofbox)
• Removablesidepanel(specialrequest)
Cableentry
100mmwallboxswingframecollar
200mmwallboxswingframecollar
4U 19” Steel Wallbox
Part No.
Part No. with
100mm collar
Part No. with
200mm collar
1R03-04UWB/GG
1R03-04UWBS1GG
1RWBST-304
Description
Height
19”4Ux
220mm
300mmwallbox
6U 19” Steel Wallbox
Part No.
Part No. with
100m m collar
Part No. with
200mm collar
1R04-06UWB/GG 1R04-06UWBS1GG 1R04-06UWBS2GG
2
Description
Height
19”6Ux
310mm
400mmwallbox
WallMount Boxes
9U 19” Steel Wallbox
Part No.
Part No. with
100mm collar
Part No. with
200mm collar
1R04-09UWB/GG 1R04-09UWBS1GG 1R04-09UWBS2GG
Description
Height
19”9Ux
440mm
400mmwallbox
12U 19” Steel Wallbox
Part No.
Part No. with
100mm collar
Part No. with
200mm collar
1R04-12UWB/GG 1R04-12UWBS1GG 1R04-12UWBS2GG
Description
Height
19”12Ux
575mm
400mmwallbox
15U 19” Steel Wallbox
Part No.
Part No. with
100mm collar
Part No. with
200mm collar
1R04-12UWB/GG 1R04-12UWBS1GG 1R04-12UWBS2GG
Description
Height
19”15Ux
710mm
400mmwallbox
20U 19” Steel Wallbox
Part No.
Part No. with
100mm collar
Part No. with
200mm collar
1R04-20UWB/GG 1R04-20UWBS1GG 1R04-20UWBS2GG
Description
Height
19”20Ux
930mm
400mmwallbox
3
Server Racking Solutions
AdleRac® 10U Server Rack
Key Features
•Flexibleandmodularrackingsystem
•Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
•Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Gold Range
GoldRange
10U600mmx600mm
The Gold Range from AdleRac® is its most popular rack and is the stalwart
in the range. This popular rack was designed to industry standard DIN41494
specifications. Its frame is constructed from toughened lightweight extruded
aluminium and finished with stylish and distinctive detailing.This compact rack
is extremely modular in design and thus offers customers freedom of installed
equipmentandexceptionaleaseofuse.
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
• This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
PlatinumRange
10U600mmx1m
• The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
Technical Specifications
4
Rack Height 10U
600 x 600 mm
600 x 800 mm
600 mm x 1,0 m
NetWeight
30KG
32.2KG
38KG
MaximumHeight
650mm
650mm
650mm
MaximumWidth
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
ShippingWeight
60KG
62.2KG
68KG
ShippingHeight
680 mm
680 mm
680 mm
ShippingWidth
630 mm
630 mm
630 mm
ShippingDepth
630 mm
830 mm
1030 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
Server Racking Solutions
AdleRac® 13U Server Rack
Key Features
•Flexibleandmodularrackingsystem
•Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
•Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Gold Range
The Gold Range from AdleRac® is its most popular rack and is the stalwart
in the range. This popular rack was designed to industry standard DIN41494
specifications. Its frame is constructed from toughened lightweight extruded
aluminium and finished with stylish and distinctive detailing.This compact rack
is extremely modular in design and thus offers customers freedom of installed
equipmentandexceptionaleaseofuse.
GoldRange
13U600mmx600mm
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
•This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
PaltinumRange
13U600mmx1m
Technical Specifications
Rack Height 13U
600 x 600 mm
600 x 800 mm
600 mm x 1,0 m
NetWeight
38.2KG
40KG
44.2KG
MaximumHeight
795mm
795mm
795mm
MaximumWidth
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
ShippingWeight
68.2KG
70KG
74.2KG
ShippingHeight
825mm
825mm
825mm
ShippingWidth
630 mm
630 mm
630 mm
ShippingDepth
630 mm
830 mm
1030 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
5
Server Racking Solutions
AdleRac® 20U Server Rack
Key Features
•Flexibleandmodularrackingsystem
•Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
•Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D
1992
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Gold Range
GoldRange
20U600mmx600mm
The Gold Range from AdleRac® is its most popular rack and is the stalwart
in the range. This popular rack was designed to industry standard DIN41494
specifications. Its frame is constructed from toughened lightweight extruded
aluminium and finished with stylish and distinctive detailing.This compact rack
is extremely modular in design and thus offers customers freedom of installed
equipmentandexceptionaleaseofuse.
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
•This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
PlatinumRange
20U600mmx1m
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
Technical Specifications
6
Rack Height 20U
600 x 600 mm
600 x 800 mm
600 x 1,0 m
NetWeight
55.2KG
57KG
61.2KG
MaximumHeight
1100 mm
1100 mm
1100 mm
MaximumWidth
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
ShippingWeight
85.2KG
87KG
115KG
ShippingHeight
1130 mm
1130 mm
1130 mm
ShippingWidth
630mm
630mm
630mm
ShippingDepth
630 mm
830 mm
1030 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
Server Racking Solutions
AdleRac® 25U Server Rack
Key Features
•Flexibleandmodularrackingsystem
• Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
• Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
GoldRange
25U600mmx600mm
Gold Range
The Gold Range from AdleRac® is its most popular rack and is the stalwart
in the range. This popular rack was designed to industry standard DIN41494
specifications. Its frame is constructed from toughened lightweight extruded
aluminium and finished with stylish and distinctive detailing.This compact rack
is extremely modular in design and thus offers customers freedom of installed
equipmentandexceptionaleaseofuse.
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
• This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
PlatinumRange
25U600mmx1m
Technical Specifications
Rack Height 25U
600 x 600 mm
600 x 800 mm
600 x 1,0 m
600 x 1,2 m
NetWeight
59.2KG
74.2KG
95.2KG
98.2KG
MaximumHeight
1350mm
1350mm
1350mm
1350mm
MaximumWidth
600 mm
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
1200 mm
ShippingWeight
89.2KG
104.2KG
125.2KG
128.2KG
ShippingHeight
1380mm
1380mm
1380mm
1380mm
ShippingWidth
630 mm
630 mm
630 mm
630 mm
ShippingDepth
630 mm
830 mm
1030 mm
1230 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
1000 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
BlackorGrey
7
Server Racking Solutions
AdleRac® 34U Server Rack
Key Features
•Flexibleandmodularrackingsystem
•Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
•Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
GoldRange
34U600mmx600mm
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Gold Range
TheGoldRangefromAdleRac®isitsmostpopularrackandisthestalwartinthe
range.ThispopularrackwasdesignedtoindustrystandardDIN41494specifications.
Itsframeisconstructedfromtoughenedlightweightextrudedaluminiumandfinished
with stylish and distinctive detailing. This compact rack is extremely modular in
designandthusofferscustomersfreedomofinstalledequipmentandexceptional
easeofuse.
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
•This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
PlatinumRange
34U600mmx1m
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
Technical Specifications
8
Rack Height 34U
600 x 600 mm
600 x 800 mm
600 x 1,0 m
NetWeight
65KG
81.6KG
84.6KG
MaximumHeight
1720mm
1720mm
1720mm
MaximumWidth
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
ShippingWeight
95KG
111.6KG
114.6KG
ShippingHeight
1750mm
1750mm
1750mm
ShippingWidth
630 mm
630 mm
630 mm
ShippingDepth
630 mm
830 mm
1030 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
Server Racking Solutions
AdleRac® 38U Server Rack
Key Features
•Flexibleandmodularrackingsystem
•Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
•Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
GoldRange
38U600mmx600mm
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Gold Range
TheGoldRangefromAdleRac®isitsmostpopularrackandisthestalwartinthe
range.ThispopularrackwasdesignedtoindustrystandardDIN41494specifications.
Itsframeisconstructedfromtoughenedlightweightextrudedaluminiumandfinished
with stylish and distinctive detailing. This compact rack is extremely modular in
designandthusofferscustomersfreedomofinstalledequipmentandexceptional
easeofuse.
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
• This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
PlatinumRange
38U600mmx1m
Technical Specifications
Rack Height 38U
600 x 600 mm
600 x 800 mm
600 x 1,0 m
NetWeight
84.4KG
88.2KG
92.4KG
MaximumHeight
1900mm
1900mm
1900mm
MaximumWidth
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
ShippingWeight
114.4KG
118.2KG
168.18KG
ShippingHeight
1930mm
1930mm
1930mm
ShippingWidth
630 mm
630 mm
630 mm
ShippingDepth
630 mm
830 mm
1030 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
9
Server Racking Solutions
AdleRac® 43U Server Rack
Key Features
•Flexibleandmodularrackingsystem
•Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
•Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
GoldRange
43U600mmx600mm
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Gold Range
The Gold Range from AdleRac® is its most popular rack and is the stalwart
in the range. This popular rack was designed to industry standard DIN41494
specifications. Its frame is constructed from toughened lightweight extruded
aluminium and finished with stylish and distinctive detailing.This compact rack
is extremely modular in design and thus offers customers freedom of installed
equipmentandexceptionaleaseofuse.
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
•This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
PlatinumRange
43U600mmx1m
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
Technical Specifications
10
Rack Height 43U
600 x 600 mm
600 x 800 mm
600 x 1,0 m
600 x 1,2 m
NetWeight
103.2KG
107.4KG
109.2KG
111.3KG
MaximumHeight
2120 mm
2120 mm
2120 mm
2120 mm
MaximumWidth
600 mm
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
1200 mm
ShippingWeight
133.2KG
137.4KG
139.2KG
141.8KG
ShippingHeight
2150mm
2150mm
2150mm
2150mm
ShippingWidth
630 mm
630 mm
630 mm
630 mm
ShippingDepth
630 mm
830 mm
1030 mm
1230 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
1000 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
BlackorGrey
Server Racking Solutions
AdleRac® 47U Server Rack
Key Features
•Flexibleandmodularrackingsystem
•Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
•Raisedtopforventilation
•Adjustablefeet(levellingscrews)
•Hingedandremovablemetalsidepanelsandreardoor
•Hingedandremovableglassfrontdoor
•Fullrangeofaccessoriesavailable
•Arangeofstandardsizesandvariantsavailable
•Adjustabledepthreducers
•Adjustablepunchedprofiles
•Allmetalcomponentsareepoxypowdercoated
•CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
GoldRange
47U600mmx600mm
•AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Gold Range
The Gold Range from AdleRac® is its most popular rack and is the stalwart
in the range. This popular rack was designed to industry standard DIN41494
specifications. Its frame is constructed from toughened lightweight extruded
aluminium and finished with stylish and distinctive detailing.This compact rack
is extremely modular in design and thus offers customers freedom of installed
equipmentandexceptionaleaseofuse.
FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith
lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners;
raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet.
Platinum Range
•This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
PlatinumRange
47U600mmx1m
Technical Specifications
Rack Height 47U
600 x 600 mm
600 x 800 mm
600 x 1,0 m
600 x 1,2 m
NetWeight
149KG
151KG
166KG
170.2KG
MaximumHeight
2300 mm
2300 mm
2300 mm
2300 mm
MaximumWidth
600 mm
600 mm
600 mm
600 mm
MaximumDepth
600 mm
800 mm
1000 mm
1200 mm
ShippingWeight
143.2KG
147.4KG
149.2KG
151.8KG
ShippingHeight
2330 mm
2330 mm
2330 mm
2330 mm
ShippingWidth
630 mm
630 mm
630 mm
630 mm
ShippingDepth
630 mm
830 mm
1030 mm
1230 mm
WeightCapacity(staticload)
1363.64KG
1363.64KG
1363.64KG
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
1022.73KG
1022.73KG
1022.73KG
MinimumMountingDepth
262.00mm
262.00mm
262.00mm
262.00mm
MaximumMountingDepth
450mm
650mm
800 mm
1000 mm
Color
BlackorGrey
BlackorGrey
BlackorGrey
BlackorGrey
11
Server Racking Solutions
24” Data Centre Racking
Key Features
• Flexibleandmodularrackingsystem
• Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills
• Internallyreducedto19”
• Perforatedfrontandreardoors.
• Easytojoinandbaying.
• Raisedtopforventilation
• Adjustablefeet(levellingscrews)
• Hingedandremovablemetalsidepanelsandreardoor
• Splitfrontandreardoors
• Additional100mmoneithersideforCableManagement
• Cableentrymadepossiblefromtoporbottom
• Fullrangeofaccessoriesavailable.
• Fittedwithhightensilesecurity“combinationlock”
• Standard3pointlockingsystemapplied
• Availablein43uand47uHeights
• Adjustabledepthreducers
• Adjustablepunchedprofiles
• Allmetalcomponentsareepoxypowdercoated
• CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992
• AdleRac®isanSABSISO9001:2008certifiedmanufacturer
Platinum Range
•This rack features a range of aesthetic enhancements and features including
ventilatedfrontandrearpanels
•Fullyconfigurabletocustomerrequirements
•The system is designed with the unique requirements of every customer in
mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis
accomplished by us providing a large range of standard components and
accessorieswhichcanbefittedtotherackwithease.
Technical Specifications
12
Technical Specifications
Rack Height 43U
800 x 1,2 m x 24”
Rack Height 47U
800 x 1,2 m x 24”
NetWeight
189KG
NetWeight
190KG
MaximumHeight
2120 mm
MaximumHeight
2300 mm
MaximumWidth
800 mm
MaximumWidth
800 mm
MaximumDepth
1200 mm
MaximumDepth
1200 mm
ShippingWeight
210.9KG
ShippingWeight
220.9KG
ShippingHeight
2150mm
ShippingHeight
2330 mm
ShippingWidth
830 mm
ShippingWidth
830 mm
ShippingDepth
1230 mm
ShippingDepth
1230 mm
WeightCapacity(staticload)
1363.64KG
WeightCapacity(staticload)
1363.64KG
WeightCapacity(dynamicload)
1022.73KG
WeightCapacity(dynamicload)
1022.73KG
MinimumMountingDepth
262.00mm
MinimumMountingDepth
262.00mm
MaximumMountingDepth
1000 mm
MaximumMountingDepth
1000 mm
Color
BlackorGrey
Color
BlackorGrey
IP Rated Racking Solutions
IP Wall Boxes
Key Features
Sheetsteeldooratfront(180°),withcomforthandleforsemi-cylinder
andsecuritylock3524E;sheetsteeldooratrear(130°)withhandle
andsecuritylock3524E.
Material:
Sheetsteel/3CR12StainlessSteel
Surface finish:
Enclosureframe:
Dipcoat-primed
Doorsandroof:
Dipcoat-primed,powder-coatedin
RAL7035
Glandplatesand
punchedsectionswith Zinc-plated,passivated
mountingflanges:
Supply includes:
Enclosureframewithdoors,roof
plate,multi-pieceglandplate,2
punchedsectionswithmounting
flangesintheenclosuredepth.
DetaileddrawingavailableontheInternet.
IP Wall Box Sizes
Item
U Size
Dimension Y
1
6U
347mm
2
9U
480 mm
3
12U
614 mm
4
15U
748mm
13
IP Rated Racking Solutions
IP54 and IP65 Cabinets
Key Features
Sheetsteeldooratfront(180°),withcomforthandleforsemi-cylinder
andsecuritylock3524E;sheetsteeldooratrear(130°)withhandle
andsecuritylock3524E.
Material:
Sheetsteel/3CR12StainlessSteel
Surface finish:
Enclosureframe:
Dipcoat-primed
Doorsandroof:
Dipcoat-primed,powder-coatedin
RAL7035
Glandplatesand
punchedsectionswith Zinc-plated,passivated
mountingflanges:
Supply includes:
Enclosureframewithdoors,roof
plate,multi-pieceglandplate,2
punchedsectionswithmounting
flangesintheenclosuredepth.
DetaileddrawingavailableontheInternet.
IP65 Cabinet Sizes
14
Item
USize
DimY
DimX
1
25U
1479mm
600/800/1000
2
34U
1880mm
600/800/1000
3
38U
2057mm
600/800/1000
4
43U
2279mm
600/800/1000
5
47U
2457mm
600/800/1000
Co-Location Cabinets
The AdleRac® co-location range has been designed to accommodate the
requirements of multi user requirements.Available in a range of formats. There
areachoiceof4differentconfigurationsavailableinmultiplefootprintsizes.Inthe
continuedstruggleforrealestatewithinthedatacentre,theco-locationrangewill
providethemaximumutilisationofspace.
Co-Location
Witharangeofchoicesavailablethereisaco-locationcabinetforanyinstallation.
This can be combined with anyAdleRac® cabinet to provide a solution for any
co-location environment and provide additional revenue per square metre. The
productissuppliedwithsecureinternalcabletrunkingtoprovidetotalsecurityfor
eachcompartment.Thistrunkingcanbeaccessedfromthetopandthebottomof
eachenclosure.Securityhandlesareusedtoensurecustomerprotection.
Typical Applications
• ServerFarms
• MultipleCo-LocationDataCentres
• HostingCentres
15
Co-Location Cabinets
Full Rack
Features List
• MeshfrontdoorswithcombinationlockswithmasterKeyoverride
• MeshreardoorswithcombinationlockswithmasterKeyoverride
• 19inchmountingangles(2xRear2xfront)
• 1,2,4and9optionco-locationcabinets
• 2 way cable secure ducting accessible in each location and top and bottom
access
• HeavyDutyCastorsfittedasstandard
• Earthingkitssuppliedtoeachsection
• Two compartment or four compartment options available. Fitted with vented
doorstothefrontandrearasstandard
• Fullyenclosedbayswithfullyventeddividershelves
• Enclosedcableductingfittedasstandard
• Fullrangeofaccessoriesoptionalandadaptable
Benefits and Additional Features
• Floorspaceoptimisation
• CompatablewithbayingAdleRac®DataandServerCabinets
• CompatabilitywiththefullrangeofAdleRac®accessories
• Multiple working variants available to assist in providing differing levels of
security
Typical Applications
• ServerFarms
• MultipleCo-LocationDataCentres
• HostingCentres
16
Co-Location Cabinets
2-Way Split Rack
Features List
• MeshfrontdoorswithcombinationlockswithmasterKeyoverride
• MeshreardoorswithcombinationlockswithmasterKeyoverride
• 19inchmountingangles(2xRear2xfront)
• 1,2,4and9optionco-locationcabinets
• 2 way cable secure ducting accessible in each location and top and bottom
access
• HeavyDutyCastorsfittedasstandard
• Earthingkitssuppliedtoeachsection
• Two compartment or four compartment options available. Fitted with vented
doorstothefrontandrearasstandard
• Fullyenclosedbayswithfullyventeddividershelves
• Enclosedcableductingfittedasstandard
• Fullrangeofaccessoriesoptionalandadaptable
Benefits and Additional Features
• Floorspaceoptimisation
• CompatablewithbayingAdleRac®DataandServerCabinets
• CompatabilitywiththefullrangeofAdleRac®accessories
• Multiple working variants available to assist in providing differing levels of
security
Typical Applications
• ServerFarms
• MultipleCo-LocationDataCentres
• HostingCentres
17
Co-Location Cabinets
4-Way Split Rack
Features List
• MeshfrontdoorswithcombinationlockswithmasterKeyoverride
• MeshreardoorswithcombinationlockswithmasterKeyoverride
• 19inchmountingangles(2xRear2xfront)
• 1,2,4and9optionco-locationcabinets
• 2 way cable secure ducting accessible in each location and top and bottom
access
• HeavyDutyCastorsfittedasstandard
• Earthingkitssuppliedtoeachsection
• Two compartment or four compartment options available. Fitted with vented
doorstothefrontandrearasstandard
• Fullyenclosedbayswithfullyventeddividershelves
• Enclosedcableductingfittedasstandard
• Fullrangeofaccessoriesoptionalandadaptable
Benefits and Additional Features
• Floorspaceoptimisation
• CompatablewithbayingAdleRac®DataandServerCabinets
• CompatabilitywiththefullrangeofAdleRac®accessories
• Multiple working variants available to assist in providing differing levels of
security
Typical Applications
• ServerFarms
• MultipleCo-LocationDataCentres
• HostingCentres
18
9-Way Split Rack
Features List
• MeshfrontdoorswithcombinationlockswithmasterKeyoverride
• MeshreardoorswithcombinationlockswithmasterKeyoverride
• 19inchmountingangles(2xRear2xfront)
• 1,2,4and9optionco-locationcabinets
• 2 way cable secure ducting accessible in each location and top and bottom
access
• HeavyDutyCastorsfittedasstandard
• Earthingkitssuppliedtoeachsection
• Two compartment or four compartment options available. Fitted with vented
doorstothefrontandrearasstandard
• Fullyenclosedbayswithfullyventeddividershelves
• Enclosedcableductingfittedasstandard
• Fullrangeofaccessoriesoptionalandadaptable
Benefits and Additional Features
• Floorspaceoptimisation
• CompatablewithbayingAdleRac®DataandServerCabinets
• CompatabilitywiththefullrangeofAdleRac®accessories
• Multiple working variants available to assist in providing differing levels of
security
Typical Applications
• ServerFarms
• MultipleCo-LocationDataCentres
• HostingCentres
19
ETSI Cabinets
TheETSIstandardisthecurrentformatforenclosuresusedintheTelecommunicationsindustryandhasbeenestablishedbytheEuropeanTelecommunications
StandardsInstitute-henceETSI.The19”standardisageneralpurposeformat
usableinawidevarietyofapplicationsincludingTelecommunications.
Whereas ETSI enclosures are meant specifically for telecommunications
applicationsandtohousetelecomequipmentbuilttotheETSIformat.However,19”
RackmountableequipmentcanalsobehousedinETSIcabinetsthroughtheuse
of19”adapterswhichconvertfromETSIdimensionsto19”mountingdimensions.
Buttheoppositeisnotpossible-i.e.ETSIequipmentin19”Racks.
ETSIcabinetsaregenerallyof2200mmheightoverall,andeither300mmor600mm
depth,overall.Cableentryprovisionisprovidedattopandbottom.Rearpanelsand
frontdoorsareoptional.Twoversionsareonofferthe300mmD“SHALLOW”ETSI
Rackwhichhasfixedsidepanels,andthe600mmD“DEEP”ETSIRackwhichhas
removablesidepanels.
Benefits and Features
• Toppanelofrectangularboxtypeshape
• TopandbottomcableentryprovisionwithglandplatesM10liftingboltprovision
• PairofETSIpanelmounts(2.0mmsteel)withzincplatingandyellowpassivation
asastandardsupply
• 4pairsofpanelmountsupports
• Basic frame of welded construction made from steel sheet 1.6mm thick, and
powder-coated
• Sidepanelsandbottompanelshavingvents,madefrom1.6mmsteelsheet
• Steel&glassdoorin1.6mmsteel;rearpanelin1,6mmsteel
20
Custom Racking Solutions
Adlerac® Slack Rack
Theidealsolutionformassivecabledensitiesexperiencedtodayby
sprawlingenterprises.Thisslackcabinetdoesexactlywhatitsname
implies-takealltheexcesscableandstoresitawayneatly.Itfits
flushagainstAdleRac®’sGoldRackandthusblendsinharmoniously
withitsenvironment.
Available in heights of 38’U’, 43’U’ and 47’U’ 300mm wide with
depthsof600mmand900mm.
Adlerac® Comms Rack
This is the ideal solution for all telecommunications rooms. This
AdleRac® cabinet is fitted to a telecoms wall and houses the
interconnectingblocksforalltelecommunicationslinksfromoutside
thebuilding.
Various telecoms panel options are available.Available in heights
of38’U’,43’U’and47’U’300mmdeepand600mmor900mmwide
optionsavailable.
Adlerac® Split Rack
ThisingeniousdesignfromAdleRac®istheidealsolutionforserver
rooms where various people need to operate on the cabinet.The
cabinetissplitandhasthreelockablecompartments.Thebottomis
wheretheserverishoused,inthemiddleisyourlockablekeyboard
withmonitorandswitchingequipment.Thisdesignenablesaccess
to the right people to the right equipment. Thereby securing that
unnecessarydowntimeisavoided.
Adlerac® Ventilated Rack
ThisAdleRac®wasdesignedforequipmentthatrequireshighlevels
ofcoolinginenvironmentsthatareexposedtoinsects.Allcooling
panelsareventilatedandaccessintotherackissealed.
21
Rack Accessories
Accessories
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Front mounting equipment trays
Flat mounting equipment shelves
Sliding trays
Mini keyboard sliding trays
Power distribution duct
Cable trays
Additional punched profiles
Additional depth reducers
Cooling fans
Patching panels (various types)
Blank panels
Cable management panels
Gland plates
Mounting hardware
Mobile bases (castors)
IEC Powerduct with display
Ventilation Fan Panel
Please call for complete range of
accessories
Fan Trays
Recess panel with DIN rail
Cable management trays
Sliding keyboard trays
Drawer Unit
Cable management panels - Telkom
Flat mounting equipment shelves
22
THE ULTIMATE PDU
9072/14370
• SABS approved Power
Distribution Units
• Robust aesthetically
pleasing design
• Conforms with both
national and international
sockets
• 16A rated at 250Vac
• Fitted with 1x additional IEC
60320 C13 10Amp socket
• Easy installation into rear
of rack via pre-punched
mounting holes
COMMITTED TO SERVICE EXCELLENCE
23
APS Basic PDW Range
9072/14370
C13
C19
SouthAfricansocket
Schukosocket
PowerStripC13
Britishsocket
OurAPSBasicRangePDU’shavetheadvantageofbeingbefittedwitha32AIEC309(Caravan/Commando)styleplug.
PDU’Switha32AmpIEC309plugandtheSouthAfricanstyle16Asocket,ortheGermanstyle15ASchukosocket,andthe
13ABritishsocketshavethedisadvantagethatyoucannotdrawthefull32Afromthesupply.Inmostapplicationsthisisnota
problem,astheequipmentconnectedtothePDUdoesnotdrawmorethanthecurrentofthecircuitbreaker,i.e.wherethere
isa32Asocketprovided,thePDUneedsaplug.Theconnectedequipmentthendoesnotneed32Aintotal.
16A Rated PDU
Features
• 16Aratedat250Vac
• Protectedwith16Acircuitbreaker
• Fittedwith1xadditionalIEC60320C1310Asocketfor
theconnectionoffantraysandother19”Rackequipment
• 5metre3core1.5mmSQincominglead
• Availableintwolengthswitheither5or10socketsrated
16A
• EasyinstallationintorearofRackviapre-punched
mountingholes
APS Part Number
Description
APS Part Number
Description
1RA-PDW05/SABS
APS5wayPDUSABSGrey
1RA-PDW10B/SABS APS10wayPDUSABSBlack
1RA-PDW05B/SABS
APS5wayPDUSABSBlack
1RA-PDW10G/SABS APS10wayPDUSABSGrey
1RA-PDW05B/16A
APS5wayPDU+3092P+E16APlugBlack
1RA-PDW10B/16A
APS10wayPDU+3092P+E16APlugBlack
1RA-PDW05G/16A
APS5wayPDU+3092P+E16APlugGrey
1RA-PDW10G/16A
APS10wayPDU+3092P+E16APlugGrey
1RA-PDW05B15/32A
APS5wayPDU+3092P+E32APlugGrey
1RA-PDW10B15/32
APS10wayPDU+3092P+E32APlugBlack
1RA-PDW05G15/32A
APS5wayPDU+3092P+E32APlugGrey
1RA-PDW10G15/32
APS10wayPDU+3092P+E32APlugGrey
32A Rated PDU
Whenafull32Ampcurrentdrawisrequired,APShasdevelopedasecondoptionthatcanprotectuptoamaximumof10
16Ampsockets,byfittinga32Ampcircuitbreaker.Weofferacost-effectivesolutiontothisapplication.
Features
• 32Aratedat250Vac
• Protectedwith32Acircuitbreaker
• Fittedwith1xadditionalIEC60320C1310Asocketfor
theconnectionoffantraysandother19”Rackequipment
• 5metre3core2.5mmSQincomingleadfittedwith
IEC30932Aplug(Caravan/Commandotype)
• Availableintwolengthswitheither5or10socketsrated
16A
• EasyinstallationintorearofRackviapre-punched
mountingholes
APS Part Number
Description
APS Part Number
Description
1RA-PDW0530B/32
APS5wayPDU+32ACB+32APlugBlack
1RA-PDW1030B/32
APS10wayPDU+32ACB+32APlugBlack
1RA-PDW0530G/32 APS5wayPDU+32ACB+32APlugGrey
24
1RA-PDW1030G/32 APS10wayPDU+32ACB+32APlugGrey
APS IEC PDU Range
TherecentlyintroducedAPSIECPDUrangefeaturesthecompleterangeofIEC60320sockets.TheprimaryinletsareC13
orC19sockets.TheincomingplugsareavailablefromthestandardSouthAfrican3pin16AtotheIEC30916Aand32A.On
requesttheC20/C19inlineplugandsocketcanbeaccommodatedonthestandard5meterincominglead.
15A Rated PDU
Features
• 15Aratedat250Vac
• Protectedwith16Acircuitbreaker
• 12PortC1319”x1Uhorizontalorverticallyasper
bracketsetsupplied
• 5metre3core2.5mmSQincomingleadfittedwith
IEC30916Aplug
• Finishedingreyorblack
APS Part Number
Description
APS Part Number
Description
1RA-IEC12WC13/1
APSIEC12wayC13PDU+5MSAP/TOPGrey
1RA-IEC12WC13/7
APSIEC12wayC13PDU309-32A2P+EGrey
1RA-IEC12WC13/B APSIEC12wayC13PDU+5MSAP/TOPBlack
1RA-IEC12WC13B7 APSIEC12wayC13PDU309-32A2P+EBlack
APS Part Number
Description
APS Part Number
1RA-IEC12WC13/3
APSIEC12wayC13PDU309-16A2P+EGrey
1RA-IEC12WC13D1 APSIEC12wayC13PDU+DISPGrey
1RA-IEC12WC13B3 APSIEC12wayC13PDU309-16A2P+EBlack
1RA-IEC12WC13D2 APSIEC12wayC13PDU+DISPBlack
Description
25
The IP-EV Bio Unit Enclosure
ThecostofData,ordinarilyoutweighsthecostofanyotherasseta
companycanhaveintoday’sworld.Thus,itisimperativethatitis
amplyprotectedagainsttheft,fire,wateretc.
Adlerac’ design experts have engineered a first-class all-rounder
solutionwhichfeaturesthe
..best of both worlds…
Incorporating the EV or Environmental Enclosure’s, versatile
interiorcontainmentwithhighqualityIngressProtected(orNEMA)
featuresbuilttotherequiredstandardofprotectionneededagainst
rust&corrosion,moisture,dustand/orimpact,andagainstintrusion
fromforeignbodies.
EV Enclosures
The “EV Enclosure” stands for Environmental Enclosure, and is
essentially an enclosure which secures, manages and controls its
own internal environment. .It is an access controlled server rack
which is self-contained with a secure environment hosting all of
the features which you would typically find in a well thought out
“computerroom”.
The ‘Environment’ of the enclosure’s interior is monitored, using
state-of-the-art technology and gear. The Enclosure is specifically
designed to accommodate internally mounted air-conditioning,
critical for the management and control of the enclosure’s Interior
environment.
TheEVenclosureismodularindesign,thusallowingforexpansion
tomeettheneedsoftheamountofhardgearandequipmentneeding
storageandprotection.Thisallowsasingle,double,tripleorquad
setofEVEnclosuregrouping,thusprovingacost-effectivesolution
designedtomeetdifferentrequirements.
TheEVEnclosureisahigh-securityenclosurepreventingunwanted
intrusion.The level of security can be selected, using bio-metrics,
including Retina Pattern Biometric Systems, Voice Patterns
BiometricsSystems,orFingerprintsBiometricsystems.
The EV Enclosure can be provided with an early-warning system,
byinstallingaremotemonitoringunit,whichmeasurestemperature,
humidity,dewpoint,airflow,andaudiblesounds(e.g.alarms).This
active monitoring, early detection and instant alerting system can
graphabnormalities,recordvideo,takepictures,andrecordsound
clips as soon as intrusion is detected. All this information can be
accessedremotely,andtheunitsendsoutalertsandwarningsvia,
SMS,E-mail,SNMP,FTP,HTTPandWebServices.Warningsare
sentoutassoonasoneofthewarningsystemsaretriggered.
TheEVEnclosureisdesignedwithinsulatedandremovablepanels,
andcabledistributionsystemsallowingforeasymanagementand
control of cabling and access. All parts are either epoxy powder
coated, or plated – to exude a superior finish.Your company logo
canbebrandedonthefrontoftheplexi-glassdoor.
Contactoneofourenclosurespecialists,foranexcitingpreviewof
an exclusive, yet cost-effective all-in-one solution for your server
enclosureneeds.
26
The IP-EV Bio Unit Enclosure
Specifications
Sheetsteeldooratfront(180°),withcomforthandleforsemi-cylinder
andsecuritylock3524E;sheetsteeldooratrear(130°)withhandle
andsecuritylock3524E.
Construction and manufacture
• The construction of the Cabinet’ Structure is Rigid – it is full
throughTigwelded,andmanufacturedin2.0mmMildSteeland
hasanEpoxyPowderCoatedfinish.
• Doorsaremanufacturedin1.6mmMildSteelandhaveanEpoxy
PowderCoatedfinish.
• Doorshavea3-PointSwing-handlekey-lockSystem.
• HingesareSolid-Brassforhighersecurity.
• TheconstructionoftheCabinetisRigid
Compliance
TheI.P–EVBioUnitcompliestotheElectronicIndustriesAlliance
(EIA)’s - 310D Standard for 19” Racking. It defines a 1.75-inch
(44.45mm=1U)‘rackspace’height,anda19-inch(482.6mm)width
tomakeequipmentinterchangeablewithincommonhousings.
It also complies to the German Institute of Standardisation or DIN
(DeutschesInstitutfurNormunge.V.)’s41494SC48DStandardfor
19”Racking.
Different Solutions Available
Accordingtothelevelofsecurityand/orprotection,youcanmake
yourselectionfromthefollowingoptions:
Lighting Solution:
• HighQualityOsramLEDLightingiswiredintotheUnit,providing
sufficientlight,operatesontriggersseteitherbydoorcontactors
orelectricallocks.
High Security Solution:
• A Sagem fingerprint scanning Biometrics unit, with keypad is
installed(Thisbiometricsunitisproventobeoneoftheleading
brands in the world, and is used for government security
worldwide.)
• Ahigh-securityElectronic3-PointisinstalledwiththeBiometrics
unit,inadditiontothestandardlockingsystem.
• Aback-upbatteryisinstalledfortheElectronicLockingSystem.
Remote Access Early Warning & Monitoring Solution:
• ANetbotzUnitisInstalled,whichisinvaluabletoprotectingData.
Fire Extinguishing Solution:
• APyrora2UFireDetecting&ExtinguishingUnitisInstalled.
27
EV-Rack® Anatomy
Condensation
Tray
Air-Conditioner
Flashing
TopMount
Air-Conditioner
FrontDoorwith
ToughenedGlass
AccessControl
Panel
Removable
SidePanelwith
100%Insulation
RigidMetal
Frame
Sandblasted
Company
Logo
SecureMag-Lock
DepthReducer
SlackRack
2xCableTrays
PerRack
EV-Rack 1
EV-Rack 2
28
Plinth
EV-Rack® Configuration
The drawings show standard
configurationsoftheEV-Racks®.
SingleEVRack
EV-Racks® Racks are logically
configured as illustrated for the
purposeofeffectivelyutilizingthe
fullpotentialofthefeatures.
Forexampleasingleair-conditioning
unit can be used to effectively
control the temperature in a
single, double, triple or quad EVRacks®, so depending on the
amountofequipmentusedbythe
customer,acost-effectivesolution
can be designed to meet all the
requirements.

DoubleEVRack
Features and options provided
byaccesscontrolandmonitoring
systems can be exploited to a
greaterdegreethusjustifyingthe
inclusionoftheseintothesystem
Whatever the configuration of
the EV-Racks®, it will always be
a continuous closet. This will
facilitate seamless patching and
cross connecting of equipment
andpatchpanelswithouthavingto

TripleEVRack
provide for additional reticulation
betweenracks.
The drawings show the recommended configurations but the
EV-Racks® system is not limited
to these. It is possible to assemble the system into a five way
andevenasixwayifyourI.Tand
Business Infrastructure requires
it.Futureproofingyourrackingrequirementisastandardbasedon

QuadEVRack
CapacityManagement.
Our
specialists
can
consult
with you to determine the exact
requirements
and
design
a
suitable solution for your specific
application
29
EV-Rack® Access Control – Suprema
IP based Fingerprint Access Control
BioEntry Plus is an IP based fingerprint access control device featuring easy
installation and user friendly operations. Integrated with both fingerprint and
proximitycard,BioEntryPluscoversafullrangeofaccesscontrolapplicationsfrom
asimplestandalonedoorcontroltocomplexnetworkedaccesscontrolsystems.
WeprimarilyusethisunitonSingleEVRackapplications.
Specifications
CPU
400MHzDSP
Memory
4MBflash+8MBRAM
Fingerprintsensor
500dpiopticalsensor
Identificationspeed
2000matchin1second
Fingerprintcapacity
5000fingerprinttemplates
Logcapacity
50000events
RFcard
125KHzproximity(EM)
Operationmodes
Fingerprint,RFcard,RFcard+fingerprint
Networkinterface
TCP/IP,RS485
Wiegandoutput
Configurableupto64bits
TTLI/O
2inputsforexitswitchanddoorsensor
Internalrelay
Deadbolt,EMlock,doorstrike,automaticdoor
Soundandinterface
Multi-colorLEDandmulti-tonebuzzer
Operatingvoltage
12VDC
Size
50x160x37mm(WHD)
Incorporating Suprema’s industry-leading fingerprint recognition algorithm,
BIOSTATIONoffersaperfectsolutionforaccesscontrol.
WithacolorLCDandhighqualitysound,BIOSTATIONprovidesadifferentlevelof
userinteractionusingmultimediainformation.Versatileinterfaceoptionsincluding
wireless LAN and USB memory slot enable easy network integration and data
transferwithoutanywiring.
WeprimarilyusedthisonDouble,TripleandQuadEVRackapplications.
Specifications
CPU
DualCPU(32bitRISC+400MHzDSP)
Memory
72MBflash+34MBRAM
Display
2.5”QVGA16MColorLCD
Identificationspeed
3,000matchin1second
Fingerprintcapacity
50,000fingerprinttemplates
Logcapacity
500,000events
RFCard
125kHzEMCard,HIDProx.(Optional)
Networkinterface
WirelessLAN(optional),TCP/IP,RS485
PCinterface
USB,RS232
USBmemoryslot
USBHost
Outputrelay
Deadbolt,EMlock,doorstrike,automaticdoor
WiegandI/O,4TTLI/O
Microphoneandspeakerfordoorphone
Navigationkeyformenumovement
4Functionkeysforuser-definedfunctions
30
Operationmodes
Fingerprint,PIN,PIN+Fingerprint,Card,Card+Fingerprint,
Card+PIN(RFmodel)
Size
135x128x50mm(WxHxD)
EV-Rack® Thermal Management – Panasonic
PerformancecommunicationsandIThardwarehavethecapacitytogenerateheat.
ThetemperatureinRackhousingthisequipmentcanrisequiterapidly.Inmany
instanceregulationoftemperatureinachievedbyexpellinghotairfromtherack
whilstcolderairfromacontrolledcomputerroomwillbedrawnintotherack.Since
the EV-Rack®isastand-alonehousingforhighperformancecommunicationsand
IThardwareitcannotrelyonthesurroundingenvironmentforregulatingitsinternal
temperature.Thus the use of an air-conditioning unit is an essential part of the
concept.
Ofthe many options available we recommend one of the following solutions for
EV-Rack®ThermalManagement:
• Topmountingair-conditioner
• Sideattachingair-conditioner
DependingontheconfigurationofyourEV-Rack®ourspecialistscanadviseonthe
mostsuitablesolution.
Top Mounting Air-conditioning unit Common Features
• Reciprocatinghermeticcompressorwiththermal-amperometricprotection
• EcologicR134arefrigerant,CFCfree
• Condensingandevaporatingheatexchangecoilsincopperpipewith
aluminiumfins
• Internalandexternalfansonballbearingswithinternalthermalprotection
• Mechanicalcontrolthermostatsetat35°C,deadband4°C
• SteelsheetfrontcoverpowderpaintedRAL7032orangepeel(gray)
• Nofilter
• Allmodelshavetheheatexchangersurfacesspecificallydesignedtoprevent
cloggingbyparticlesandfibresintheambientair.Therefore,theyremainvery
efficientevenintheworstambientconditionsandfiltersareeliminated.
• Condensatedissipator
• Unitsequippedwithacondensatedissipator;adevicethatsolvestheproblems
ofcondensatemanagementandevacuation.
• Environmentsafety
• Inallstages,fromthedrawingboardtothecreationofourproducts,EEC
safetyregulationsandenvironmentalresourcesarerespected,usingecological
gasesandrecyclablematerials
• Doublecondensateprotectionsystem
• EBB
• Thisisadevicewhichallowselectronicmanagementofthemainconditioner
functions.
Hide-Away Panasonic Top Mount Air-conditioner
This is an 18,000 BTU air-conditioning unit particularly suitable for installations
requiringhighvolumesofcooledairasanalternativetooneoftheaboveoptions.
Theunitis27cmhighandlightweightmakingitideaforthisapplication,itisalso
easilymaintainedwithflexibleaccesstofilters.
* Fullspecificationavailableonrequest;pleaseconsultoneofourspecialistsfor
moreinformation.
31
EV-Rack® Fire Suppression – PanelSafe®
Data processing, telecommunications, ISPs and production plants are today
increasinglydependentonthepermanentavailabilityoftheirelectronicequipment.
Failure of such equipment leads to severe disruption and consequent loss of
revenue.Effectivefireprotectioniscrucialbecauseitisoftennotonlythefirebut
thefumesthatdamagethecomponents.
Features
• Space saving
– 19”-unitwith4Uinheight
• Rapid detection
– Smokedetectorslocatedwithinthe19”cabinet
• Minimising damage
– viaautomaticshutdowncontact
• Rapid extinguishment
– duetothedirectdischargeoftheFM-200orNovec1230
suppressantwithinthecabinet
• Simple installation and commissioning
– withpre-assembledcomponents
• Easy maintenance
– duetomodularconcept
• Quick and safe recognition of events
– reportedviadetailedmultifunctionaldisplay
• Safe protection of large cabinets
– Evencabinetsupto6m3canbeprotectedbyusingslave
units
Specifications
32
Inputsupply
230VAC±15%
OutputVoltage
24VDC,1A,forexternalcontrolpurposes,sounderandextinguishingfan
Battery
2Ah(sufficientfor4hours)
Smokedetectors
2opticalscatteredlightdetectorsusedintwo-detectorcoincidencedetection
Supervisedin-andoutputs
formainssupply,smokedetectors1&2,manualrelease,extinguishingfan,alarmhorn
Voltage-freerelayoutputs
forpre-alarm,mainalarm,commonfaultandshutdowncontact(contactload30VA)
Suppressant
FM-200,C3F7H/N2(25bar)orNovec1230,C6F12O/N2(25bar)
Suppressantcylinder
1litre,foramaximumof1.2m3protectedvolume,approvedaccordingtoRL97/23/EGandRL
1999/36/EG
Operatingtemperaturerange
0°Cupto40°C
Weight
Approximately14kg
Indications
Mains supply, CPU, common fault, smoke detectors 1 & 2, manual release, extinguishant
container (pressure switch), extinguishing fan, sounder, external control, discharge actuator,
pre-alarm,mainalarm,discharge(suppressantreleased)
Servicebuttonsresp.keyswitch
Uniton/off,extinguishmenton/off,reset
Dimensions
Width
19”
Height
4Uinheight
Mountingdepth
403.25mm
EV-Rack® Monitoring – Geist
IT equipment continues to push upward in both power consumption and cooling
demand.FormostITManagers,understandingwhereandwhenthesepowerand
environmental conditions impact data center dynamics and reacting to adverse
conditions can be a daunting task. Geist’s RacSense® line of products brings
visibilitytothefingertipsofdatacentermanagers,allowingfortheultimateinremote
monitoring of environmental conditions. Whether your data center is across the
building,acrossthecountry,oraroundtheworld,RacSense®keepsyouincontrol.
Conveniently Accessed
Diagnostic Data
♦User-definedgraphingvariables
♦Logdataavailableforexportto
XML
♦Logdataavailablereal-timevia
SNMPorXML
♦PDAandWAPscreenformats
♦User-definedalarmthresholds
♦Simultaneousaccessbymultiple
users
♦Diagnosticeventlogfor
situationalanalysis
Timely Monitoring and Alarm
Notification
♦SNMPtrapsforalarmsetand
alarmclear
♦E-mailnotification
♦Audiblealarm(GRSE2X16only)
♦Combinationsoftheabove
Protected Access
♦Multi-levelpasswordprotection
♦Viewonlyprivileges
♦HTTPS(SSL&TLS)forsecure
link
Friendly Names
♦Units&sensorsmaybegiven
logicalnames
Self-Contained Operation
♦Noclientsoftwarerequired
♦Viewableviawebbrowser
♦Interfaceswithremotedisplay
andwebcamera
Simple Installation
RSE-B
♦StaticIP-viewableviaweb
browser
♦DHCPIPassignments(optional)
♦Automatictimesetviainternet
timeservers
RSE-2X16
Ease of Expansion
♦Externalsensorsmaybeadded
atanytime
RSMINI163
♦Externalsensorsare
automaticallydiscovered
33
ATEN Data Center KVM Solution Guide
Limitless control over the Data Center
ATEN Solutions are ideal when you or your client...
• IsaDataCenterManager,ITInfrastructureManager,NetworkManager,Directorof
Operationsorisaninfrastructuredecisionmakeraboutnetworkinghardware,power
orserverracks
• Isplanningadatacenterupdateorbuildinganewdatacenter
• Has purchased multiple servers for the same location or has remote or branch
offices
• UsesmultiplePCsonthesamedesk
• Needsremote,BIOSlevelaccessthatKVMandserialoverIPsolutionsprovideto
managecriticalequipment
• Issettingupaco-locationordisasterrecoverysite
• HaslimitedITStaff
• Hasalargewebserverenvironment
Q:Whatdoyoudowhenrackspaceisatapremiumand
youneedaccesstomultipleserversremotely?
A: KL1516, CAT5 Dual Rail 16-Port LCD KVM Switch
•IntegratedKVMconsolewith17”or
19”LCDmonitorinaDualRailhousing
•RJ-45connectorsandCat5cable
–extendsthedistancebetween
computersandswitchupto40m
130ft.forresolutionsof1280x1024
@60Hz
Q:Areyoulookingforaqualityenterprise-levelCAT5KVM
solutionatanSMBpricepoint?
A: KH1508/KH1516, 8/16-Port CAT5 KVM Switch
•Asingleconsolecontrolsupto8or
16directlyconnectedservers
• Daisy chain up to 31 additional
unitsandcontrolupto256or512
computersfromasingleconsole
•Nosoftwarerequired
Q:Whatdoyoudowhenserversgodownatdatacenteror
remotelocations?
A: PN9108, 8-port Power Over the Net
•Remotepoweron/off/rebootcontrol
foreightoutletsviaTCP/IPanda
builtin10/100Ethernetports
•Daisychainupto15additional
stationstocontrolupto128outlets
Q:Doyoucurrentlyhaveadatacenterbutnoremote
access?
A: CN8000, Over the Net IP KVM Access Unit
•Allowsaccessandcontrolof
computersremotely
•Supportsupto64useraccounts
•VirtualMedia
•CompatiblewithallATENKVMs,
andmostcompetitors’KVMs
34
Q:Aretheresystemadministratorswhotestapplications
beforeactualinstallationonthetargetserver?
A: CS62DU, 2-Port DVI USB KVM
•OneDVIvideoconsolecontrolstwo
USBcomputers
•FullyDVI-Digitalcompliantwith
resolutionsupto1920x1200@60Hz;
DDC2B
•Compactdesign,builtinall-in-one
cables
ATEN Data Center KVM Solution Guide
Q:Doyouhavenetworkadministratorsoutsideofthedata
centerthatneedaccessatalltimes?
A: CE800, USB Console Extender
•ConnecttheLocalandRemoteUnits
upto820ft.
•Built-inUSBportonbothunitssupports
externalUSBflashdrivesforeasyfile
sharing
•Pushbuttonlocksoutthenon-active
console
Q: Howcanyou,astheITDirectorornetworkadministrator,
managealloftheATENIPproductsconcurrently?
A: CC2000, Control Center Over the NET™
•CC2000Managementsoftwareoffersa
convenienteconomicalCentralized
accessandmanagementofyourIT
deviceslocatedinRemoteDataCenters
andbranchofficesanywhereintheworld
Q: Doyouwanttohavemorethantwoadministrators
simultaneouslymanageyourmulti-platformserversfrom
onelocation?
A: KM0932, 9-user, 32-Port CAT5 Matrix KVM
•Nineconsolesindependentlyand
simultaneouslycontrolupto32
computersdirectly
•Multi-platformsupportforPC,Mac
andSUN
•Consoleconversioncancontrol
anytypeofcomputercombinations
(PS/2&USB)
Q: Doyouhavemultipleserialdeviceslikerouters,firewalls,
UNIXservers,andotherserially-controlleddevicesyou
wouldliketomanage?
A: SN0116, 16-Port Serial Over the Net KVM Switch
•Remoteserialaccessoverthe
internetforupto16serversor
otherserialITdevices
•Eachportcanbeaccessed
individuallyby16users
•Multi-levelsecureuserlogin;user
authentication;port-specificaccess
rights
Q:Doyouwanttomanageyourserversbothlocallyand
remotely?
A: KN2116, 3-user, 16-Port KVM Over the Net
•3simultaneousloginsfromany
workstationonyourLANorWAN,
orfromtheInternet..
•Canbecascadedtoamaximum
of128compatibleKVMsallowing
controlforupto1024computers.
•Messageboardfeature
35
KVM Solutions – ATEN
CS1794
2/4-Port USB 2.0 HDMI KVMP™ Switch
Combining a 4-port switch with a 2-port USB 2.0 hub, the
CS1794providesseamlessHDMIsignalswitchingbetween
4PCsorotherHDMI-enableddevices,andallowsusersto
share USB peripherals from a single console.The CS1794
provides enhanced independent switching via front panel
pushbuttons and keyboard hotkeys, and features Video
DynaSync™ technology to ensure that HDMI display
resolutionisalwaysoptimized.Withintegrateddigitalaudio,
the CS1794 also allows users to experience high-definition
sound,suchasDolbyTrueHDandDTSHDMasterAudio.
Features:
•OneUSBconsolecontrolstwo(CS1792)orfour(CS1794)
HDMI-interfacecomputersandtwoadditionalUSB
devices
Specifications
ComputerConnections
4
FrontPanelPushbuttons;
PortSelection
Hotkeys
1xUSBTypeAFemale
Keyboard
(Black;rearpanel)
1xHDMITypeAFemale
Video
(Black)
Console
1xUSBTypeAFemale
Mouse
Ports
(Black;rearpanel)
2xMiniStereoJackFemale
Speaker
(Green;1xfront,1xrear)
2xMiniStereoJackFemale
Mic.
(Pink;1xfront,1xrear)
Connectors
Keyboard/ 4xUSBTypeBFemale
Mouse
(White)
4xHDMITypeAFemale
Video
(Black)
KVM
Ports
4xMiniStereoJackFemale
Speaker
(Green)
4xMiniStereoJackFemale
Mic.
(Pink)
1x4-conductor3.5mmJack
F/WUpgrade
(Black)
Emulation
•DolbyTrueHDandDTSHDMasterAudiosupport
•Superiorvideoquality–supports480i,480p,720p,1080i,
and1080p(1920x1200)
•Powerondetection:whenoneofcomputersisswitched
offtheKVMwillswitchautomaticallytothenextpower-on
computeraccordingly
•Supportswidescreenresolutions
•Multiplatformsupport–Windows2000/XP/Vista,Linux,
andMac
•Consolemouseportemulation/bypassfeaturesupports
most mousedriverandmultifunctionmice
•VideoDynaSyncTM–storestheconsolemonitorsEDID
(ExtendedDisplayIdentificationData)tooptimizedisplay
resolution
•Mackeyboardsupportandemulation*
Selected
Audio
2xUSBTypeAFemale
(White;1xfrontpanel;1x
rearpanel)
5xPushbutton
5(Green)
KVM
5(Orange)
USB
Keyboard/Mouse
5(Green)
USB
1080p(HDTV)/1920x
1200(DVI)
1-99secs.(Default:5secs)
DC5.3V,4.8W
0-50ºC
-20-60ºC
0-80%RH,Non-condensing
Metal,Plastic
0.53kg
Video
ScanInterval
PowerConsumption
OperatingTemp.
Environment
StorageTemp.
Humidity
Housing
Physical
Weight
Properties
Dimensions
(LxWxH)
36
•HDMIdigitalandanalogmonitorsupport–fullycompliant
withHDMI1.3a;alsoHDCPcomplaint
•Completekeyboardemulationforerror-freebooting
USB2.0Hub
LEDs
•IndependentswitchingofKVM,USBperipheral,andaudio
focusviafrontpanelpushbuttonsandhotkeys
1xDCJack
Power
Switches
• 2-portUSB2.0hubbuiltin;fullycompliantwiththeUSB
2.0specification
26.50x7.30x4.50cm
•AutoScanModeformonitoringallcomputersandHDMI
devices
• FirmwareUpgradable
KVM Solutions – ATEN
CL1008
8-Port Slideaway™ LCD KVM Switch
The CL1008 / CL1016 LCD KVM Switch series are control
units that allow access to multiple computers from a single
keyboard, video, and mouse (KVM), console. A single
CL1008orCL1016cancontrolupto8or16computers.As
manyas15additionalKVMswitchescanbedaisy-chainedto
theCL1008/CL1016,sothatupto256computerscanallbe
controlledfromasingleKVMconsole.
The CL1008 / CL1016 offers a space-saving, streamlined
approachtoKVMswitchtechnologybyintegratingakeyboard,
17” LCD monitor, and touchpad in a 1U rack-mountable
slidinghousing.
Features:
• IntegratedKVMconsolewithanLCDmonitorina
Slideaway™housing
•LCDmodulerotatesupto115degreesforamore
comfortableviewingangle
•Daisy-chainupto15additionalunits–controlupto256
computers
•Nosoftwarerequired–convenientcomputerselection
viahotkeysandmousedrivenintuitiveonscreendisplay
(OSD)menus
•AutoScanfeatureformonitoringuser-selectedcomputers
•BroadcastMode–operationssimultaneouslyperformed
onallselectedcomputers,softwareinstallationand
upgrading,systemwideshutdown,etc.
Specifications
Ports
8
Expansion
128(viaDaisychain)
Computer
PlatformSupport
Connector
SPHD-15
Platform
PS/2
PC
•
Mac/Sun
•
LCD
17”
PortSelection
OSD,Hotkey,
Pushbutton
Emulation
PS/2
•Hotpluggable–addorremovecomputerswithouthaving
topowerdowntheswitch
Video
1280x1024
ScanInterval(Sec.)
1-255
•Twolevelpasswordsecurity–onlyauthorizedusers
viewandcontrolthecomputers;uptofourusersplusan
administratorwithseparateprofilesforeach
Power
Consumption
•Superiorvideoquality–upto1280x1024@75Hz
SupportsDDC,DDC2,DDC2B
Environment
•DDCemulationoftheLCDmonitor–VGAsettingsof
everyconnectedcomputerareautomaticallyadjustedfor
optimaloutputtotheLCDmonitor
•Upgradablefirmware
•KeyboardLanguagesupport:English(US);English(UK);
German;German(Swiss);French;Spanish;Traditional
Chinese;Japanese;Korean;Swedish;Italian;Russian;
Hungarian
17”LCD
120V,30W/230V,37W
OperatingTemp.
StorageTemp.
Humidity
Housing
Physical
Properties
Weight
17”LCD
13.10kg
Dimensions
(DxWxH)
63.40x48.00x4.40cm
62.60x48.00x4.20cm
Diagram
•Improveddesign–optionalsinglepersoninstallationkit
37
KVM Solutions – ATEN
KN4116 KVM Over the NET™
Features:
Specifications
Direct
Computer
Connections Max
Local
Console
Connections Remote
PortSelection
Connectors
Keyboard
Console
Video
Ports
Mouse
KVMPorts
Power
LAN
Modem
USB
16
256*(viaCascade)
1
4
OSD,Hotkey,Pushbutton
1xUSB(F)
1xHDB-15(F)
1xPS/2/1xUSB(F)
16xRJ-45(F)
1x3-prongACSocket
2xRJ-45(F)
1xRJ-45(F)
3xUSB(F)
PON
1xRJ-45(F)
Switches
LEDs
Emulation
Keyboard/Mouse
VideoResolution
ScanInterval
I/PRating
PowerConsumption
OperatingTemp.
Environment StorageTemp.
Humidty
Housing
Physical
Weight
Properties
Dimensions
Diagram
38
Power,PortSelection,Reset
OnLine,Selected,Power,
Link,10/100/1000Mbps
PS/2,USB(PC,Mac,Sun);
Serial
1600x1200;DDC2B
1-255Seconds
100-240VAC;50-60Hz;1A
110V/39.60W
230V/40.00W
0-50°C
-20-60°C
0-80%RH,Non-condensing
Metal
5.52kg
43.36x41.35x4.40cm
(19”/1U)
•Supportsupto5bussessions-1localand2(KN2132)
or4(KN4116/KN4132)remoteadministratorscan
simultaneouslyaccessseparateports
•16or32portoverIPaccess–monitorandcontrolupto
16or32computers–upto512computersinatwo-level
cascade**
•Two10/100/1000MbpsNICsforredundantLANortwoIP
operation(New)
•TwoIPdesignsupports2(KN2132)or4(KN4116/
KN4132)remotesessions(New)
•Full-screengraphicalOSDforthelocalconsole-local
consoleportswitchingaccomplishedsimplybyclicking
withthemouse(New)
•Full-screenorsizableandscalableremotedesktop
window–infull-screenmodetheremotedesktopdisplay
scalestouser’smonitordisplaysize(New)
•Remoteauthenticationsupport:RADIUS,LDAP,LDAPS,
andActiveDirectory(New)
•MagicControlPanel(New)
•Highvideoresolution:upto1600x1200@60Hz–32
bitforthelocalconsole;upto1600x1200@60Hzfor
remotesessions(New)
•MouseDynaSyncforUSBmice-localandremotemouse
movementarethesame–noneedtoconstantlyresync
thetwomovements.
•Multi-languageOSDsupport-English,German,Traditional
Chinese,SimplifiedChinese,andJapanese(New)
•LocalconsolesupportsbothPS/2andUSBkeyboards
andmice(comboconsole)
•PortscanbeindividuallyconfiguredforExclusive,Occupy,
andSharemodes
•RJ-45connectorsandCAT5ecableforaneatandtidy,
efficientinstallation-upto40mbetweencomputerand
switch
•Web-basedWindowsandJavaimplementationsallowthe
switchtobeaccessedfromaninternetbrowser
•Browseraccesscanbedisabled–WindowsandJava
GUIAPprogramsprovidedfornon-browserconnectivity–
Javaworkswithpracticallyalloperatingsystems
•PanelArrayMode–viewupto32portsatthesametime
–upto42portsforcascadedinstallations
•Software(On-screen)keyboard,AltusenCC(Control
Center)support
•ExternalmodemsupportforPPPdialin-remoteuserscan
dialinandoperateinlowbandwidthmode
•Bandwidthcontrol–Videoqualityandvideotolerancecan
beadjustedtocompensateforbandwidthvariationsin
ordertooptimizedatatransferSpeed
•Windows-basedLogServer
•Multiplatformsupport-(Win,Linux,Sun)andVT100
basedserialdevicesKVMAdaptersprovidemulti
interfaceaccess–PS/2,USB,SUNandRS-232
•Supports10Base-T,100Base-T,1000Base-T,Auto-Sense,
TCP/IP,HTTP,DNS,DHCP,PPP,UDP,ARP,Ping
•Multi-levelauthentication:superadministrator;
administrator;user;viewer–nolimitonthenumberof
eachtype
•Advancedsecurityfeaturesincludepasswordprotection
andadvancedencryptiontechnologies–1024bitRSA;56
bitDES;256bitAES;and128bitSSL
•BIOSleveltroubleshooting
KVM Solutions – ATEN
KL9108
17” LCD Console with Over the NET KVM Switch
The KL9108 is an IP-based KVM control unit that allows both local and remote
operators to monitor and access multiple computers from multiple consoles. A
singleKL9108cancontrolupto8/16computersandcanbeaccessedfromany
computer on the Net. The KL9108 features independently retractable 17” LCD
monitorandkeyboardwithbuilt-intouchpad.Tomaximizespaceinyourdatacenter
the keyboard “hides away” when not in use, while the thin profile LCD monitor
providescontinuousmonitoringofcomputers.
Features:
• IntegratedKVMconsolewith17”LCDmonitorinaDual
Railhousing
• Spacesavingtechnologywithdualbusfunctionsupport-
1remoteconsole(onebus)andtwolocalconsoles(one
bus)controlupto8computers
• Dual-bus-onelocalandoneremoteusercan
simultaneouslycontrolseparateports
• RemotelyaccesscomputersviatheLAN,WAN,orInternet
-controlyourinstallationwhenandwhereyouwant
• DualRailhousingisslightlylessthan1Uwithtopand
bottomclearanceforsmoothoperationin1Uofrackspace
• Extraconsoleport-managecomputersintheLCDKVM
switchfromanexternalconsole(monitor,PS/2keyboard,
andPS/2mouse)
• SupportsexternalPS/2mouse
• DualRail-LCDmonitorslidesindependentlyofthe
keyboard/touchpad
• LCDmodulerotatesupto120degreesforamore
comfortableviewingangle
• Consolelock-enablestheconsoledrawertoremain
securelylockedawayinpositionwhennotinuse
• SupportsdedicatedOSDandOSDToolbarinvocation
keys
• Internetbrowseraccess,WindowsClientandJavaClient
provided,JavaClientworkswithalloperatingsystems
• GraphicalOSDandgraphicaltoolbarsforconvenient,
user-friendlyoperation
• Upto64useraccounts-upto32concurrentremote
logins
• PanelArrayMode-viewall8portsatthesametime.
• Messageboardfeatureallowsloggedinusersto
communicatewitheachotherandallowsaremoteuserto
takeexclusivecontroloftheKVMfunctions
• Windows-basedLogServer
• RemotepowercontrolforattachedPowerOvertheNET™
devices
• Threelevelloginsecurity:Administrator,User,andSelect
• Advancedsecurityfeaturesincludepasswordprotection
andadvancedencryptiontechnologies-1024bitRSA,
256bitAES,56bitDES,and128bitSSL
• RADIUSserversupport
• PortscanbesettoExclusive,OccupyandShare
• NetworkInterfaces:TCP/IP,HTTP,HTTPS,UDP,RADIUS,
DHCP,SSL,ARP,DNS,10Base-T/100Base-TX,auto
sense,Ping
• Flashfirmwareupgradableovernetworkconnection
• SuperA-GradeTFTLCDPanel;ZeroDeadPixel
Guarantee
• Multiplatformsupport:Windows2000/XP/Vista,Linux,Unix
andFreeBSD.
Specifications
Computer
Connections
Direct
Max.
Local
Console
Connections Remote
PortSelection
Connectors
LEDs
Emulation
Video
OSDHotkey,Pushbutton
LAN
1xRJ-45FemaleBlack
PON
PortSelection
1x08-9Male(Black)
1xSemi-recessed
Pushbutton
2xPushbutton
Power
1xRocker
LCDPower
1xPushbutton
LCMAdjustment
4xPushbutton
Online
8(Green)
Selected
8(Orange)
Power
NumLock
1(Blue)
1(Green)
CapsLock
1(Green)
ScrollLock
Link
10/100MbDS
Keyboard/Mouse
Housing
1(Green)
1(Green)
1(Orange/Green)
PS/2
1280x1024@75Hz·
DDC2B
1600x1200@60Hz·
DDC2B
1-255Seconds
100-240VAC:50/60Hz:
1A
120V/31W230V/39W
0-40ºC
-20ºC
0--80%RH,Noncondensing
Metal
Weight
17.1kg
17”LCD
Remote
ScanInterval
lIPRating
PowerConsumption
OperatingTemp.
StorageTemp.
Environment
Humidity
Physical
Properties
1
1x6-pinMini-DINFemale
Keyboard
(Purple)
External
Console Video
1xHDB-15Female(Blue)
Port
1x6-DinMini-DINFemale
Mouse
(Green)
8xSPHO-15Female
KVMPort
(Yellow)
1x6-DinMini-DINFemale
ExternalMouse
(Green)
Power
1x3-prongACSocket
Reset
Switches
8
64(viaCascade)
1
Dimensions(LxWxH) 70.5x48.2x4.4cm
39
KVM Solutions – ATEN
KM0932
17” LCD Console with Over the NET KVM Switch
Features:
Hardware
• 9consolesindependentlyandsimultaneouslycontrolupto32
directlyconnectedservers
• Flexibleexpansion-theinstallationcangrowasyourneeds
grow
• Audiosupportformultimedia-capabledevices
• Redundantpowersupplyfor24x7reliability
• Multiplatformsupport:PC,Mac,Sun,andSerialConsole
access–anytypeofconsolecancontrolanytypeof
computer;mixedcombinations(PS/2&USB)supportedon
boththeconsoleandcomputersides
• Compactdesign–rackmountsinonly1Uofrackspace
Ease-to-Use Interface
• Fullscreengraphicaluserinterface–savesontrainingtime
andcosts–increasesuserefficiency
• Embeddedwebinterfaceforeasysystemconfigurationand
management
• Compositetreeview–allconnecteddevicesareintegratedin
asingledevicetreeforconvenientmanagementaccessand
control
• Theportlistautomaticallyexpandswhenstationsareadded
–portnamesareautomaticallyreconfiguredwhenthestation
sequencechanges
• Multilingualuserinterfacesupport–English,German,
Japanese,Korean,TraditionalChinese,SimplifiedChinese,
Russian
Convenient Port Operation
• ComputerselectionviaGUIorintuitivehotkeycombinations
• Portlevelaccesscontrol–userscanonlyaccesstheports
theyhavebeenauthorizedfor–whetherinasingle-stationor
multi-stageinstallation
• Userscanaccessfeaturesonmultiplecomputers
simultaneously–ausercanbeworkingandlisteningto
musiconcomputer1whileutilizingvirtualmediaoncomputer
2atthesametime.
Diagram
• Versatileportoperationmodesforflexibleserver
management:
• Broadcastsupportenablesexecutingthesamecommandon
multipleserversatthesametime
Management
• Supportsupto1024userand255groupaccounts
• Threelevelpasswordsecurity:SuperAdministrator,
Administrator,User
• Stringentpasswordpolicyfeaturesthatincludepassword
expiration;requiredpasswordchanges,accountdisabling,
andaccountexpiration.
• IntelligentPathAssignment–amasterstationcanallocate
thebestavailablepathfortheuserundermulti-path
cascadinganddaisy-chaining
• PowerOvertheNET™integrationforpowercontrol
• PowerAssociationenablestheswitch’sKVMportstobe
associatedwithaPN0108’spoweroutletsforremotepower
managementoftheserversfromtheswitch’sinterface
• RS-232portloginsupportpermitsanadministratortocontrol
theKVMportaccessforallconsolesconnectedtoswitch–
anyconsolecanbeassignedtoaccessanyKVMportfroma
singleinterfacepoint
• SessionManagement–aKillSessionfunctionprovides
administratorswiththeabilitytoforceuserlogouts
• Backupandrestoreofconfigurationsettingsanduser
accountinformation
• Firmwareupgradescanbeperformedsimultaneouslyon
alldaisychainedandcascadedslaveswitchesaswellas
connectedadaptercables
• AdapterID–adaptercable’sconfigurationinformationis
storedwiththeadapter–noneedtoreconfiguretheadapter
whenmovingaservertoanewport
• EventLogsupport
Virtual Media
• VirtualMediasupportletsyoumapstoragemediatoservers
thatareconnectedtotheswitchallowingoperatorsto
conductfiletransfers,installapplicationsandOSpatches,
andperformdiagnosticsfromasingleconsole
• WorkswithUSBenabledserversattheoperatingsystemand
BIOSlevels
• SupportsDVD/CDdrives,USBmassstoragedevices
Video
• User’sdisplayautomaticallyadjuststoresolutiondifferences
ontheremoteservers
• Superiorvideoquality–1280x1024@60Hzforupto300m
• AutoSignalCompensation(ASC)assuresoptimumvideo
resolutionfordistancesupto300mbetweencomputersand
consoles–noDIPswitchsettingrequired
• Enhancedvideoqualityviaautomaticskewcompensation
supportfortheKA7240consolemodule,andthenewerKVM
adaptercableseries(KA7120,KA7170,KA7130,KA7176)
40
In-Line Power Monitoring Solutions
RemotePower&EnvironmentalMonitoring
RacSense® Master
Feature
Benefit
Remotepowermonitoring
Preventdown-timewithearlynotificationofusageexceedinguserdefinedlimits
5on-boardclimatesensors
Currentstatusandtrenddataforenvironmentalconditionsincludingtemperature,relativehumidity,
airflow,lightandsound
4remoteclimatesensorports
Monitortemperature,airflow,humidityanddewpointviaconnectedsensors(optional)*
3I/Osensorports
Abilitytomonitorcontactclosuredevicesorscale0-5Vsignalssuchasdoorposition,waterdetection
(optional)*
Thresholdalarms(remote&local)
Immediatenotificationviae-mail,SNMPtrapsand/orlocalaudiblealarm(GRSD2X8foraudible)
Remotedisplay(GRSD)port
Easilyviewablepower&climatedataviaGRSD2X8
Accessibleviaanywebbrowser
Simpleinstallation,Noexternalsoftwaretoload
InterfaceswithIPwebcameras
Visualmonitoringofcabinetorcomputerroom
*Foracompletelistofoptionalsensorsvisitwww.geistintl.com
Specifications
InternalEnvironmentalSensors
-Temperature:-55Cto79C,+/-.5C
-Humidity:0-100%,+/-5%
-AirFlow:0-99,relative
-SoundLevel:0-99,relative
-LightLevel:0-99,relative
G
L
pa ERrt 103
#:
G1 PS6
13 -10
PS
6
Amps
10
16
16
32
Volts
230
230
230
230
C-20/C-19
2P+E,16A,
250V
2P+E,32A,
250V
IEC309InputSocket/
C-14/C-13
OutputConnector
•
6R
6R
pa ERrt 102
#:
G1 PS6
13 -10
PS
5
GL
pa ERrt 102
#:
G1 C19
13 -10
4 C2
GL
G
L
pa ERrt 101
#:
G1 C13
13 -10
3 C1
0R
• RemoteDisplay(RSD2X8)
-ConnectionJack
• ExternalSensorConnectionPorts
-FourRJ12Jacks
(addupto16remotesensors)
-ThreeI/OPorts
-0-5VDCanalogorcontactclosure
4R
• InternalPowerSensors
-VoltsRMS:80-280VAC
-AmpsRMS:0-32A
• PowerOnIndicator
• IdleIndicator
• ActivityIndicator
• SoftwareResetButton
Input / Output Power
Leads
3m
3m
3m
3m
DimensionsH(mm)
44
44
44
44
DimensionsW
432
432
432
432
DimensionsD
114
114
114
114
41
Local & Remote Current Monitoring
Local&RemoteCurrentMonitoring
Ethernet Meter
Instantaneouscurrentfeedbackidealforinstallation&maintenance
SNMPtrapsandalarms
IntegrationintoSNMPsystemsforremotenotification
User-friendlyGUIinterface
Quicklylocatepertinentinformation
IPaddressresetbutton
EaseofreconfigurationuponmoveorlossofIPaddress
Accessibleviaanywebbrowser
Simpleinstallation,Noexternalsoftwaretoloadorlose
G
L
pa MErt 10
#: 3P
G1 S6
12 -10
PS
0
G
L
pa MErt 10
#: 2P
G1 S5
11 6-1
9
0P
6S
G
L
pa MErt 10
#: 2P
G1 S6
11 -10
8
PS
G
L
pa MErt 10
#: 2C
G1 19
11 -10
C2
7
G
L
pa MErt 10
#: 1C
G1 13
11 -10
C
6
Amps
10
16
16
16X3~
32
32X3~
Volts
230
230
230
230/400WYE
230
230/400WYE
C-14/C-13
C-20/C-19
2p+E,16a,
250v
3p+N+E,16a,
230/400v
2p+E,32a,
250v
3p+N+E,32a,
230/400v
Input/OutputPowerLeads
3m
3m
3m
3m
3m
3m
DimensionsH(mm)
89
89
89
89
89
89
DimensionsW
312
312
312
312
312
312
DimensionsD
51
51
51
51
51
51
IEC 309 Input Socket / Output
Connector
Specification:+/-2%AccuracywithFullScale50/60Hzsinewaveinput
42
6S
Preventdown-timewithearlynotificationofusageexceedinguserdefinedlimits
Localcurrentmonitoring(digitaldisplay)
S5
6S
Remotecurrentmonitoring
0S
Benefit
14
S
Feature
Basic Local Power & Current Monitoring
BasicLocalPower&CurrentMonitoring
PM-1 & CM-3
Instantaneouspower&currentfeedbackidealforinstallation&maintenance
10
Volts
IEC 309 Input Socket / Output
Connector
16
L
pa AL-1
rt
#: 03PS
G1 56
13 -10
2
PS
G
G
L
pa CL-1
rt
#: 03P
G1 S613 10P
1
S
G
G
L
pa AL-1
rt
#: 02PS
G1 56
13 -10
0
P
L
pa CL-1
rt
#: 02P
G1 S612 10P
9
S
16
6R
6R
R
G
G
L
pa CL-1
rt
#: 02C
G1 1912 10C
8
20
L
pa CL-1
rt
#: 01C
G1 1312 10C
7
14
Amps
56
R
Localpower/currentmonitoring(digitaldisplay)
S5
6R
Benefit
R
Feature
16X3~
32
32X3~
230
230
230
230/400
230
230/400
WYE
C-14/C-13
C-20/C-19
2p+E,16a,
250v
3p+N+E,16a,
230/400v
2p+E,32a,
250v
3p+N+E,16a,
230/400v
Input/OutputPowerLeads
MeterType
3m
3m
3m
3m
3m
3m
Pm-1
Pm-1
Pm-1
Cm-3
Pm-1
Cm-3
41
41
41
41
41
41
432
432
432
432
432
432
DimensionsD
41
41
41
41
41
41
Amps
Volts
IEC309InputSocket/Output
Connector
Input/OutputPowerLeads
MeterType
10
16
16
16X3~
32
230
230/400
WYE
2p+E,32a,
250v
3p+N+E,
32a,
230/400v
6S
S5
GL
pa AErt 103
#: P
G1 S5
12 6-1
6 0P
GL
pa CErt 103
#:
G1 PS6
12 -10
PS
5
6S
S5
pa AErt 102
#: P
G1 S5
12 6-1
4 0P
6S
16
GL
GL
pa CErt 102
#:
G1 PS6
12 -10
PS
3
0S
G
L
pa CErt 102
#:
G1 C19
12 -10
2 C2
0
G
L
pa CErt 001
#:
G1 C19
11 -00
C2
3
G
L
pa CErt 001
#:
12 C13
41 -00
C1
6
4
6S
DimensionsH(mm)
DimensionsW
32X3~
230
230
230
230230/
400 WYE
C-14/C-13
C-20/C-19
C-20/C-19
2p+E,
16a,250v
3p+N+E,
16a,
230/400v
N/A
N/A
3m
3m
3m
3m
3m
Pm-1
Pm-1
Pm-1
Pm-1
Cm-3
Pm-1
Cm-3
DimensionsH(mm)
64
64
64
64
64
64
64
DimensionsW
159
159
210
210
210
210
210
DimensionsD
41
41
51
51
51
51
51
PM-1Specification:+/-2%AccuracywithFullScale
50/60Hzsinewaveinput
PM-1:auto-scrolling,
PowerFactor,Amps,Volts,Watts
CM-3Specification:+/-3.5%AccuracywithFullScale
50/60Hzsinewaveinput
CM-3:auto-scrolling,
3PhaseAmpsonlymeter
43
RacSense® Variable Speed Fan Controller (FC-3-2)
Maintainoptimalcabinettemperaturewhilereducingfannoise,extendingfanlife
andconservingenergy.TheGeistVariableSpeedFanControllertakesreal-time
temperaturemeasurementsandautomaticallyadjuststhefanspeedaccordinglyto
protectyourequipment.
Specification:
•Automatedmaintenanceofoptimalcabinettemperature
•Webaccessibleremotemonitoringandmaintenance
•DualA/Cinput-autoswitchingintheeventofapowerfailure
•InstantnotificationalarmsviaSNMPtrap,e-mailand/oraudiblebuzzer
•CompatiblewithShadedPoleandSplitCapacitorACfans
•Recessed1Uhorizontalmountingwithattachedbrackets
•ConserveEnergy
•Reducefannoise
•UL®&c-UL®Listed60950
•Cordsnotincluded
•Chassisdimensions:1.72”Hx17.1”Wx3.52”D
Fanspeedautomaticallyadjustsbasedonhighesttemperaturemeasured.
44
RacSense® Variable Speed Fan Controller (FC-3-2)
Local Input
Local Output
•90Vto264V(autosensing)
• DualA/Cinput-twoIECC14
-autoswitchingineventofpowerfailure
-90-264Voltautosensing
• RJ-45ethernetconnection
-accessviawebbrowser
-directconnectionavailableviacrossovercable
•4RJ12jacksforremotetemperaturesensor
connection
•Fanspeedmanual/localoverrideviarotaryswitch
-unplugethernetconnection
-setpointchangebuttonmustbepressedwhile
activatingrotaryswitch
-rotaryswitchwithrecessedscrewdriverslot
-manualtemperatureset-pointsof65°-100°F
-manualfullonsettingfor100%fanspeed
•3IECC13outletsforfanconnection,267watts
peroutlet
• Fanspeedcontrolof30-100%
• Scrollingdigitaldisplayofreal-timemeasurements
-setpointtemperature
-internaltemperature
-fourexternaltemperaturesensors
-fanspeedpercentage
• Audiblealarmwithsilenceresetbutton
• FanrunningvisualindicatorLED’s
-speed-runningatalevellessthanFullOn-
orangeLED
-fanmanuallyoff-orangeLED
-remotecontrol-orangeLED
-fanFullOn-orangeLED
-overtemp-redLED
Remote Input
Remote Output
ThreeLevelsofPasswordProtection
•Temperatureset-pointsof65°-100°F
• OptionalFullOnsettingfor100%fanspeed
• Friendlydeviceandsensornames
• CelsiusorFahrenheitselection
• Lowandhightriplevelselection
• Alarmnotificationselection(SNMPtrap,e-mail
and/oraudiblebuzzer)
•Real-timemeasurementsandgraph
-internaltemperature
-fourexternaltemperatures
-fanspeed
-set-pointtemperature
• LogdataavailableforexportviaXMLorreal-time
viaSNMP
• Eventlogwithvariablecontentsettings
• VisualimagedisplayfromoptionalIPaddressable
camera
• AlarmsviaSNMPtrapore-mail
45
Server Technology® Power Distribution Units
If you manage a data center, we have a Cabinet Power Distribution Unit (CDU) solution for you.
How do I...
Basic
CDU
Power High Density Server Cabinets?
Metered
CDU
Smart
CDU
Switched
CDU
X
X
X
-48VDC
CDU
Rack-Mount
Fail-Safe
Transfer
Switch
Distribute Power in a Cabinet?
X
X
X
X
X
X
Provide Branch Circuit Protection?
X
X
X
X
X
X
Monitor True RMS current?
X
X
X
Distribute and load balance 3-Phase Power?
X
X
X
X
Receive SNMP based alerts/email alerts?
X
X
X
X
Know when the cabinet temperature is too
high?
X
X
X
X
X
X
X
Provide fail-safe redundant power?
X
Link two CDUs on a single IP address?
X
X
X
X
Instantly connect to an integral web based
GUI?
X
X
X
X
X
X
X
X
X
X
Remote reboot locked up servers and other
network devices with graceful shutdown?
Monitor, manage & control multiple devices in
multiple locations?
X
Load Shed non-critical devices when UPS
goes on battery or temperature /current
exceeds defined thresholds
X
Sentry: Cabinet Power Distribution Unit (CDU) Product Family
with Exclusive Integrated Temperature and Humidity Monitoring
Basic CDU
Cabinet Power Distribution and Branch Circuit Protection
Switched CDU
Flagship CDU with remote & management, including remote reboot to connected
servers and network equipment
Metered CDU
Cabinet Power Distribution with Local Input Current Monitoring and Branch Circuit
Protection
-48 VDC CDU
DC Cabinet Power Distribution with remote monitoring & management, including
remote reboot to connected servers and network equipment
Smart CDU
Power Distribution with remote monitoring and expanded functionality of SNMP
alerts including power, current, temperature and humidity
Rack-Mount Fail-Safe Transfer Switch
Power Distribution with the expanded functionality of dual A & B input power feeds
to supply redundant fail-safe power should an in-feed fail
46
Server Technology® Power Distribution Units
Sentry: CDU Product Family
The complexity of IT equipment in today’s data
centersandremotebranchofficelocationsrequires
new solutions for building a solid infrastructure.
It must support 24/7 operations and reduce the
instance of locked-up or failing equipment leading
to network downtime; Five nine’s availability –
99.999%uptime–demandsit.
Blade servers and high density computing power
requirements continue to increase, creating heat
proliferation and more challenges for managing
the IT environment. To maintain their competitive
advantage, data center managers need SNMPbased solutions that monitor, track and manage
servers and IT equipment and the equipment
cabinetinfrastructurethathousesthem.
ThephotobelowillustrateswhereeachoftheCDU’s
keyfeaturesarelocated:
Serialaccessfor
RS-232andlocal
communications.
Integrated
support
for Temperature and
Humidityprobes.
IP-enabled for Secure
Web,SSH&SNMP
management
IntegratedPower
MeteringDisplays
perbranchcircuit
orphase.
UL 60950-1 Branch
Circuitprotectionwith
ULlistedfuses.
The Sentry CDU Family delivers these
solutions with three distinct product lines:
Metered CDU
CabinetPowerDistributionwithLocalInputCurrent
MonitoringandBranchCircuitProtection.
Centerrailnotchforflush
mountingin
cabinet.
Smart CDU
Power Distribution with the expanded functionality
of SNMP-based Input Current Monitoring and
Temperature/Humiditymonitoring.
Switched CDU
Completes the solution by adding Full Remote
Monitoring & Management, including reboot
commands to connected servers and network
equipment.
120Vor208V
outputforupto84
outputreceptacles.
CDU Product Family
SolutionsfortheDataCenterEquipmentCabinet
Single-phase
orthree-phase
powerinputfor
upto20kW.
47
Server Technology® Power Distribution Units
Branch Circuit Protection
Metered CDU:
The Sentry CDU Family meets the new UL 60950-1
requirementforbranchcircuitprotection.
Key Features
Attention!TheSentryCDUproductsmeettheUL60950-1criteria
byprovidingovercurrentprotectionwithUL–listedBussman®SC
fusesforeachbranchcircuit.
TheSentryMeteredCDUproducts
provide reliable power distribution
forallthedevicesinyourequipment
cabinet,from5,000toover20,000
Wattspercabinet.
Input Current Monitoring
The CDU’s exclusive True RMS current monitoring is
critical to preventing overloads in high-density computing
environments.LEDdigitaldisplaysontheCDUenclosure
reporttheinputcurrentofeachphaseorbranchcircuit.
Single-phase 110-120V or 208240V power distribution with 20A
or 30A options -or- 3-Phase 208240V;20Aor30Apowerdistribution
options.
Button Mounting
Local input current monitoring
allows the installation engineer to
verify the aggregate load on the
circuitorphase.
All CDU’s are also compatible with button mounting.
Severalcabinetmanufacturersarenowusingthismethod
forinstallingpowerdistributionunitsinthecabinet.
Sentry: Metered CDU
Power Distribution with Input Current Monitor LED
Horizontal CDU’s
C-10H1
C-12H2
C-24H2
100-120V(2.4-3.6kW)/20Aor30A
208-240V(4.2-6.2kW)/20Aor30A
208-240V(4.2-6.2kW)/30A
(1U;5inDepth)
(1U;5inDepth)
(1U;5inDepth)
Blade Server Horizontal CDU’s
48
C-4H
C-12HD
208-240V(4.2-6.2kW)/20Aor30A
3-Ph,208-240V(14.4-21.6kW)/20Aor30A
(1U;7inDepth)
(2U;10inDepth)
Server Technology® Power Distribution Units
Smart CDU:
Key Features
The Smart CDU products provide
reliablepowerdistributioncombined
withremotepowerandenvironmental
monitoring.
Use the network interface to view
power, temperature and humidity
levels via Web browser, or receive
SNMP-basedalarmswhenconditions
exceeddefinedthresholds.
Trends Impacting
Data Center Power
Distribution
• Morehigh-density,multipleunits
fillingracksandcabinets.
Branch Circuit
Protection
Button
Mounting
Input Current
Monitoring
Temp & Humidity
Monitoring
Sentry: Smart CDU
Power Distribution with LED’s, IP-based Power,
Environmental Monitoring
Blade Server Horizontal CDU’s
•Moresystemswithhigherand
increasingpowerdensity.
•Moreuseofhigherrated
suppliestoreducecablingcosts.
• Moreuseofintelligentpower
andmetering.
• More3-Phaseapplicationsand
increaseduseofmeteringto
insureloadbalancedphasesin
suchsystems.
CS-12HD2
CS-12HD3
208-240V(8.4-12.4kW)/20Aor30A
3-Phase(14.4-21.6kW)/20Aor30A
(2U;10inDepth)
(2U;10inDepth)
Zero-U Modular 3-Phase Verticals
• Moresystemswithhigher
nominalinputvoltageratings
(208Vvs.traditional120V).
• Moreindividualpowerdistribution
unitsbeingprovidedwithan
increasingnumberofoutlets.
• Moreglobalpowerdistribution
equipmentbeingdevelopedat
20Aand30A.
• MoreuseofIEC60320outlets,
especiallyforaglobalproduct
with208Vnominalsupplyratings.
(Source:IEEE)
CW-3
CX-3
CB-8V2-A30-D1
3-Ph,208-240V/
30Aor60A
3-Ph,208-240V/
30Aor60A
208-240V
10.8-21.6kW
10.8-21.6kW
N/A
49
Server Technology® Power Distribution Units
Switched CDU:
Key Features
TheSwitchedCDUproductsprovide
thecapabilitytomonitorandcontrol
cabinet power remotely for a date
centerorremotebranchoffice.The
Switched CDU’s combine remote
configuration and management
with power distribution and power
and environmental monitoring.
Reboot a single or dual power
serverwithonecommand.Receive
SNMP alerts when power or
environmental conditions exceed
thresholds. Assign specific access
rightstodesignatedusergroupsor
individuals.
Only the Switched CDU products
provide the flexibility needed for
all data centers and remote sites,
including power requirements for
high-amperage, high voltage, UL
60950-1 Branch Circuit Protection
and SNMP traps including current
monitoring.
Switched CDU:
Expansion Module
The Expansion Module CDU CX
is our exclusive method for linking
outlets on different power circuits
together.ACXlinkstoanySwitched
CDU, increasing the number of
managed outlets on a single IP
address. Control individual outlets
oneithertheSwitchedCDUorCX,
orcontrolgroupedoutletsbetween
theSwitchedCDUandCXwithone
command.
EachCXlinkstoaSwitchedCDU,
whichcontainsbothnetworkand
serialinterfaces.Whenlinked
toaSwitchedCDU,theCX’s
outletsareauto-discoveredbythe
SwitchedCDU’sfirmware,andall
availableoutletsareviewable
andcontrollable
throughthe
A-Feed
B-Feed
firmware.
(CW)
(CX)
EachExpansion
ModuleCDU
canbea
single-power
feedhorizontal
enclosureor
asingleor
dualpower
feedzero-U
enclosure.
50
Input Current
Monitoring
Temperature and
Humidity Monitoring
Linkable Expansion
Module
Button
Mounting
Branch Circuit Protection
with Fuse Retractor
Sentry: Switched CDU
Solutions for Remote Access, Rebooting, and Power Cycling
of any attached device, anywhere in the world.
Horizontal CDU’s
CW-2H1
CW-8H1
100-120V(2.4kW)/20A
100-120V(2.4-3.6kW)/20Aor30A
(1U;4.75Depth)
(1U;10inDepth)
CW-2H2
CW-8H2
208-240V(4.2kW)/20A
208-240V(4.2-6.2kW)/20Aor30A
(1U;4.75Depth)
(1U;10inDepth)
Server Technology® Power Distribution Units
Sentry: POPS Switched CDU
Power Distribution Solutions for the Data Center Equipment Cabinet
Cabinet Power Distribution Unit with Per Outlet
Power Sensing
Sentry POPS (Per Outlet Power Sensing) combines
all the features and functions of a Switched CDU with
theabilitytoprovidepowermonitoringperanindividual
outlet/device. Power information per individual outlet /
device includes current, voltage, power (kW), apparent
power,crestfactor,andpowerfactor.Usingourgrouping
technology, power information is available per device,
groups of devices (application), individual CDU or
cabinet.
Integral Web Interface
The Sentry POPS CDU is capable of being accessed
througheitherasecurenetworkorserialconnection.The
secureintegralwebinterfaceprovidesasimpleandeasy
waytoconfiguretheCDU.
Configurationchoicesinclude,SNMPtraps,emailalerts,
grouping,andallsecurityandcommunicationsettings.
Features
• Simple,secure,integralwebinterfaceGUI
configurationtool
• TemperatureandHumiditySupport
• Authenticationlogging,configurationchangesand
systemevents
• SecureSyslogprotocolsupport
• Emailnotificationsoflog,event,authorization,power
andconfigurationmessages
• AutomaticFirmwareUpdatesviaFTPserver
• StrongPasswordSupportandPre-LoginBanner
• AbilitytoPinganIPaddresstoseeifthedeviceis
responding
• GroupingofoutletsacrossmultipleCDU’s
• SNMP:TrapsbasedonStatus,Changes,Load,
TemperatureandHumidity
• Supports104useraccountsand18simultaneous
loginswithadedicatedSNMPconnection
51
Server Technology® Power Distribution Units
Switched CDU: Access, Security & Communication
Secure Remote Administration Interface
• Easy to use secure, integral,
web based GUI configuration tool
• Temperature Support (Celsius or
Fahrenheit)
• Logging of all authentications,
configuration changes and
system events
• SYSLOG logging protocol
support
• Email notifications for multiple
users of log, event, authorization,
power and configuration
messages
• Automatic Firmware Updates via
FTP server
• Strong Password Support and
Pre-Login Banner
New “Power” Information
Communication Tools
> Input Feed Voltage (VAC)
> Web Interface (HTTP, HTTPS)
> Input Feed Watts (W)
> SSL, SSH, Telnet, SNMP, and Serial
RS-232 Access with Scriptable
Command Line Interface
> System total Watts (W)
> System footprint (sq. ft.)
> System watts per square foot
(W per Sq. ft.)
Other Communication Tools
> LDAP, LDAPS, TACACS+, and DHCP
Sentry: CDU Smart Load Shedding
Load Management based on Temperature, Infeed Load, and UPS Status
• Easy to use, integral, web based
GUI configuration tool
• Logging via SYSLOG of all load
shedding actions
• “Auto-recovery” with a reboot
delay time when conditions return
to normal
• Regular polling of UPS power
state via SNMP
• Each CDU outlet is assigned
the IP address of the connected
device for shut down notification
• Remote shutdown agent for
orderly server shut down
• SNMP trap notifications
• SMTP based email load shedding
event notification
52
Load Shedding
Server Technology is the first to offer data center managers the ability to
automatically manage CDU power outlets based on key operating parameters,
including temperature, in-feed load, and UPS power status. Each outlet may be
controlled by one or more of these parameters. Should the temperature or load
current exceed defined thresholds or the UPS lose power and go onto battery, all or
a portion of the loads may be automatically shed to ensure longer operational life of
your critical devices. If one or more servers are being shed, a controlled shut down
may be accomplished via a remote shutdown agent.
An “auto-recovery” function ensures that all devices are brought back to a defined
state when conditions return to normal.
Server Technology® Power Distribution Units
Switched -48 VDC:
Key Features
• Remote Power Management:
Combinesintelligentpower
distributionandremotepower
controlintoasingle2U,19”
rack-mountenclosure
• Qty (2) 100-Amp DC Power
Input Feeds
(AFeed&BFeed):Supports
dualpowersupplyroutersand
networkinggear
• Multiple DC Outlet Circuits:
Switched -48 VDC Power Distribution
TheSentrySwitched-48VDCCabinetPowerDistributionUnit(CDU)minimizes
the impact of locked-up routers , servers and other network devices for mission
criticalnetworks.CLECs,ILECsandISPsuseSentry-48VDCCDU’stomanage
equipment in remote sites, co-location facilities and network operations centers.
Remotedevicesthatarelocked-upcanbeeasilyrebootedwithouttheneedtosend
a technician to the site. Key applications include power distribution and remote
managementforacabinetwith-48VDCpoweredserversandhigh-amprouters.
The Sentry -48 VDC switched products provide power distribution and remote
powermanagementinacompact2U,19”rack-mountenclosure.
Other features include sequenced power up to avoid current inrush problems,
groupingofoutputstoensurethatmultiplesupplydevicescomeupatthesame
time acrossA and B power feeds, and linking for cost savings and doubling the
numberofoutputsavailableonasingleIPaddress.
EachpoweroutputterminalisprotectedbyaGMTorTPCfuseoracircuitbreaker.
Thereisawidefusecapacityrangeavailable.
ProtectedbyGMTorTPCfuses
• Outlet Circuit Protection:
Fastactingfusewithpositive
visualindicationofablownfuse
Sentry:
-48 VDC Applications
• Variable Amperage and
Interchangeable Fuses:
Matchthefusevaluetotheamp
ratingofeachoutletcircuit
Shown left are 2 Sentry 4805/35XLS-12unitsconnectedtoarouter
aswellasseveralotherlowcurrent
-48 VDC devices. Dual power infeeds ensure that a loss of either
theAin-feedortheBin-feedwillstill
allowtherouterandotherdevices
to operate on a single supply
untiltheproblemisresolved.This
provides redundancy and allows
for system maintenance without
serviceinterruption.
• IP Access:
ForRemotePowerOn,Power
Off,orReboot
• Communications and
Security:
10/100BaseTEthernet,HTTP/
HTTPS,SSLv3/TLSv1,SNMP,
SSHv2,Telnet,LDAPv3,
TACACS+,andserialport
access
• SNMP Traps:
Automatedalertsforpowerand
environmentalconditions
• PSTN:
Optionalintegratedsecure
globalmodem.
• Environmental Monitoring:
TwooptionalTemperatureand
Humidityprobes(notavailable
on4820XLSor4835XLS)
4870-XLS-4
(Master)
XLS<••>XMS Data Link Cable
• Load Sense:
Realtimereportingofthe
currentdraw,inamps,foreach
poweroutlet
• On Sense:
VerifyvoltageattheDCpower
outletcircuit
• Expansion Units:
EachSentryIntelligent-48VDC
XLSlinkstoanXMS-48VDC
unit
Shownleftare2Sentry4870-XLS/
XMSunitsconnectedtoarouterwith
dual power supplies. Each router
powersupplycontainsthreeinputs.
Twoin-feedsourceswithanH-Tap
provide power to the 4870 units.
Point of failure and maintenance
concerns are eliminated by wiring
one supply to the XLS and one
to the XMS allowing removal or
replacement of either Sentry unit
withoutinterruptingoperationofthe
router.
4870-XMS-4
(Expansion/
Redundant Unit)
53
Server Technology® Power Distribution Units
SentryTM Power Manager
Manage Multiple Cabinet Power Distribution Units (CDUs) in Multiple Locations
Key Features
• ViewyourentiresystemofCDU’s
fromaglobalviewdowntotherack
level
• Auto-DiscoversallyourSentryCDU
devices
• AccessviaStandardNetwork
Browser
• OutletClusters-Groupoutlets
withinaCDU,acrosstwoCDU’sor
acrossIPaddresses
• Logs&Reporting:detailedevent
log,devicedetailreport,current
report,andpowerreports
• IntegratedRemoteManagementof
SentryCDU’stocyclepowerand
rebootselecteddevices
• CentralisedEventLogging
• Trendingoftemperature,humidity,
power(kW)andcurrentinamps
• Simpleandeasytounderstand
alarmnotificationand
acknowledgement
• Realtimealarmnotification
• MultipleViews:Temperature,
humidity,amps,anddevicestatus
• IntegratedRemoteManagementof
SentryCDU’stocyclepowerand
rebootselecteddevices
• EmailnotificationsviatheCDU
wheneventsoccur
• SNMPtrapssentviatheCDUwhen
eventsoccur
• Abilitytoimportimages
• Multipleuserlevelsandpermissions
“Quickly drill down from a global view to the rack level”
DoyouhavemultipleSentryTMCDUsinoneormorelocationsthatyouwould
like to access from one central point? Would you like one central location
whereallalarmscanbeviewedandloggedforreporting,emailorSNMPtrap
notifications?Noproblem!
OurSentryPowerManger(SPM)productiscapableofmonitoringandmanaging
multiple Sentry devices in IP-based enterprise networks. SPM provides a
globalviewofallSentryCDUsalongwiththeabilitytoviewdevicesbasedon
theirtemperature,humidity,currentanddevicestatus.Besidesmanagingand
monitoring all alarm conditions, this information can also be used to provide
reportingandtrendinginformation.
Sentry: Additional Features
IP Addressable
Remote Power Management that combines intelligent
power distribution and remote power control. IPAccess
forRemotePowerOn,PowerOff,orReboot.
Temperature and Humidity Monitoring
Supportstwoexternaltemperatureandhumidityprobes.
Each of these probes measure both temperature and
humidity. Receive SNMP-based alert notifications when
conditions exceed defined thresholds (NotAvailable on
the4820or4835Models).
HTML GUI Interface
Sentry Switched -48 VDC products can be monitored
remotelythroughtheintegralGUIInterface.
54
Cisco® Switches
Product Positioning
The Cisco® Catalyst® family of fixed-configuration, standalone Ethernet switches
supportsenhancedswitchingservices,IPcommunications,andwirelessnetworking
for small businesses. These switches provide the performance, availability, and
manageabilitythatmodernofficeenvironmentsdemand,aswellastheintelligence
tosupportstate-of-the-artbusinessapplicationsandsecurityservices.
Cisco Catalyst switches provide:
•FastEthernetandGigabitEthernetconnectivitytothedesktoptodeliver
superiorapplicationperformance
•PoweroverEthernet(PoE)toprovide15.4WonallPoEports
•Differentlevelsofadvancedsecuritycapabilities,includingidentityservicesand
sophisticatedaccesscontrol,toprotectcriticalassets
•Differentlevelsofqualityofservice(QoS)intelligencetosupportdelay-sensitive
IPvoiceandvideoapplicationsandoptimizebandwidthinthenetwork
•Redundancyandresiliencyfeaturestoprotecttheavailabilityofcritical
applicationsatalltimes
•Simple,scalablemanagementwiththeoptiontouseacommand-lineinterface
(CLI)ortheGUI-basedCiscoNetworkAssistantwithCiscoSmartports
interfaces
•Scalabilitytocontinuallyaccommodatenewapplicationsandservicesasthe
businessevolves
Basic Layer 2 Switches
Common Features
•FastEthernetandGigabitEthernetinupto8-,554-,and48-portconfigurations
•Basicsecurity,basicQoS,standardavailability,andmulticastfeatures
(CiscoCatalystExpressandLANLiteimageforCiscoCatalyst55960Series
Switches)
•Lowertotalcostofownership(TCO)duetoscalableandsecurenetwork
managementandsimplifiedtroubleshooting
CatalystExpress500/520Series
•Limitedlifetimehardwarewarranty,andsoftwareupdatesatnoadditional
charge
Enhanced Layer 2 Switches
Common Features
•FastEthernetandGigabitEthernetin8-,24-,and48-portconfigurations
•PoEconfigurationswithupto15.4Wonupto48ports
•Networkcontrolandbandwidthoptimization,deliveredviaadvancedQoS,rate
limiting,accesscontrollists(ACLs),IPv6management,andmulticastservices
•Enhancedsecuritytoprotectusersanddevicesfromattackviaawiderangeof
authenticationmethods,dataencryptiontechnologies,andNetworkAdmission
Controlsupportbasedonusers,ports,andMACaddresses(LANBaseimage)
Catalyst2960LANLiteSeries
•SimplifiednetworkavailabilitywithfeaturessuchasFlexLinks,LinkState
Tracking,andsupportforaredundantpowersupply
•LowerTCOduetoscalableandsecurenetworkmanagementandsimplified
troubleshooting
•Limitedlifetimehardwarewarranty,andsoftwareupdatesatnoadditional
charge
Catalyst2960LANBaseSeries
55
Cisco® Switches
Layer 2 and Layer 3 Switches
Common Features
•Enterprise-class,fixed-configuration,multilayerswitches
•FastEthernetandGigabitEthernetconfigurationswith1Gigabitand10Gigabit
uplinks
•SupportforIEEE802.3afandCiscoprestandardPoE
•Abilitytodeploynetworkwideintelligentservicesforconvergedapplications
•Enhancedsecurity,advancedqualityofservice(QoS),andhighavailability
•Intelligentpowermanagementfeatures,providinggranularcontrol
•ExpressSetupandCiscoNetworkAssistantsoftwareforeasydeploymentand
configuration
•Ciscoapplication-specificintegratedcircuits(ASICs)forsuperiorhardwareand
softwareintegrationandinnovativefeatures
•Field-replaceablepowersupplyandfanontheCiscoCatalyst3560ESeries
Switches
•Limitedlifetimehardwarewarranty,andsoftwareupdatesatnoadditional
charge(Catalyst3650and3750;doesnotincludeESeries)
Catalyst3560and3560ESeries
TheCiscoCatalyst3650SeriesSwitchesareavailablewitheithertheIPBase
orIPServicessoftwareimagesandcanbeupgradedtotheAdvancedIP
Servicessoftwareimage
•TheIPBasesoftwareincludesadvancedQoS,ratelimiting,ACLs,andbasic
routingandIPv6functionality.
•TheIPServicessoftwareprovidesarichersetofenterprise-classfeatures,
includingadvancedhardware-basedIPunicastandIPmulticastroutingaswell
aspolicy-basedrouting(PBR).
•TheAdvancedIPServicessoftwareincludessupportforIPv6routingandIPv6
ACLs
Layer 2 and Layer 3 Switches with Stacking
Common Features
•Enterprise-class,fixedconfiguration,multilayerswitchingline
•FastEthernetandGigabitEthernetconfigurationswith1Gigabitand10Gigabit
uplinks
•SupportforIEEE802.3afandCiscoprestandardPoE
•Abilitytodeploynetworkwideintelligentservicesforconvergedapplications
•Enhancedsecurity,advancedqualityofservice(QoS),andhighavailability
Catalyst3750and3750ESeries
•Intelligentpowermanagementfeatures,providinggranularcontrol
•ExpressSetupandCiscoNetworkAssistantsoftwareforeasydeploymentand
configuration
•CiscoASICsforsuperiorhardwareandsoftwareintegration,andinnovative
features
TheCiscoCatalyst3750isavailablewitheithertheIPBaseorIPServices
softwareimagesandcanbeupgradedtotheAdvancedIPServicessoftware
image.
•TheIPBasesoftwareincludesadvancedQoS,ratelimiting,ACLs,andbasic
routingandIPv6capability.
•TheIPServicessoftwareprovidesarichersetofenterprise-classfeatures,
includingadvancedhardware-basedIPunicastandIPmulticastroutingaswell
asPBR.
•TheAdvancedIPServicessoftwareincludessupportforIPv6routingandIPv6
ACLs.
56
Cisco® Switches
Layer 2 and Layer 3 Switches
Decision Tree Overview
Yes
Enhanced
IPServices
Software?3
Yes
Gigabit
Ethernet
Switch
No
GigabitEthernet
Switchesw/PoE,GE
Uplinks&Enhanced
IPServicesSoftware
GigabitEthernet
SwitcheswithPoE&
GEUplinks
WS-C3560G-48PS-E 48-port GE Switch with PoE + 4 GE
SFPportswithIPServiceimage
WS-C3560G-24PS-S 2 4-port GE Switch with PoE + 4 GE
SFPportswithIPBaseimage
WS-C3560G-48PS-S 48-port GE Switch with PoE + 4 GE
SFPportswithIPBaseimage
PoE
Capability?1
No
Yes
Enhanced
IPServices
Software?3
No
Layer2
andLayer3
Switches
Yes
GigabitEthernet
Switchesw/GE
Uplinks&Enhanced
IPServicesSoftware2
GigabitEthernet
SwitcheswithGE
Uplinks2
GigabitEthernetSwitch
FastEthernet
Switchesw/PoE,GE
Uplinks&Enhanced
IPServicesSoftware2
Enhanced
IPServices
Software?3
Yes
Fast
Ethernet
Switch
WS-C3560G-24PS-E 24-portGESwitchwithPoE+4GE
SFPportswithIPServiceimage
No
FastEthernet
SwitcheswithPoE&
GEUplinks2
PoE
Capability?1
No
Yes
Enhanced
IPServices
Software?3
No
FastEthernet
Switchesw/GE
Uplinks&Enhanced
IPServicesSoftware2
FastEthernet
SwitcheswithGE
Uplinks2
WS-C3560G-24TS-E 24-portGESwitch+4GESFPports
withIPServiceimage
WS-C3560G-48TS-E 48-portGESwitch+4GESFPports
withIPServiceimage
WS-C3560G-24TS-S 24-portGESwitch+4GESFPports
withIPBaseimage
WS-C3560G-48TS-S 48-portGESwitch+4GESFPports
withIPBaseimage
WS-C3560-24PS-E
2 4-port FE Switch with PoE + 2 GE
SFPportswithIPServiceimage
WS-C3560-48PS-E
48-port FE Switch with PoE + 4 GE
SFPportswithIPServiceimage
WS-C3560-8PC-S
Compact 8-port FE Switch with PoE
+1GESFPportswithIPBaseimage
WS-C3560-12PC-S
12-port FE Switch with PoE + 1 GE
SFPportswithIPBaseimage
WS-C3560-24PS-S
2 4-port FE Switch with PoE + 2 GE
SFPportswithIPBaseimage
WS-C3560-48PS-S
48-port FE Switch with PoE + 4 GE
SFPportswithIPBaseimage
WS-C3560-24TS-E
24-portFESwitch+2GESFPports
withIPServiceimage
WS-C3560-48TS-E
48-portFESwitch+4GESFPports
withIPServiceimage
WS-C3560-24TS-S
24-portFESwitch+2GESFPports
withIPBaseimage
WS-C3560-48TS-S
48-portFESwitch+4GESFPports
withIPBaseimage
57
Cisco® Mobility Express
Cisco Mobility Express brings together the Cisco 521 Wireless ExpressAccess
PointandtheCisco500SeriesWirelessExpressMobilityControllertoprovidea
flexible,cost-effectivewirelesssolutionspecificallydesignedtomeettheneedsof
smallbusinesses.
TheCisco521accesspointisasingle-band802.11gaccesspointthatfeatures
business-class management, security, and scalability. It offers high-performance
wirelessconnectivityinofficesandsimilarenvironments.
Aspartofthissolution,theCisco521accesspointuniquelyaddressesthediverse
requirementsofsmallbusinessesthroughtheabilitytooperateeitherinstandalone
mode or in controller-based mode with the Cisco 500 Series Wireless Express
MobilityController.
• Standalonemode:Accesspointsaredirectlyconnectedtothewiredinfrastructure
throughanEthernetswitchandprovidereliablehigh-speedwirelessconnectivity
tousersintheareatheycover.Configurationandmanagementareperformed
locallyattheindividualaccesspointlevel.
• Controller-based mode: Access points are directly connected to the wired
infrastructurethroughanEthernetswitchandassociatedwithaCisco500Series
WirelessExpressMobilityController.Thecontrollerstreamlinesandmanages
theconfigurationofallconnectedaccesspointsthroughasingleinterfaceand
providesaplatformformobilityservicessuchassecureguestaccessandvoice
overWi-Fi.
Common Features
• TheCisco521WirelessExpressAccessPointisasingle-band802.11g
accesspointandisbackwardcompatiblewith802.11bdevices.
• Hardware-assistedAdvancedEncryptionStandard(AES)encryptionprovides
ahighlevelofsecuritywithoutperformancedegradation.
• TheaccesspointisIEEE802.11icompliantandWi-FiProtectedAccess
(WPA2)andWPAcertifiedtohelpensureinteroperablesecuritywithabroad
rangeofwirelessLANclientdevices.
• PoweroverEthernet(IEEE802.3af)providesaninteroperablealternativeto
ACpower.
• CiscoConfigurationAssistantsimplifiesthetaskofconfiguringandmanaging
theaccesspoints.
• TheCisco526WirelessExpressMobilityControllersimplifiesthedeployment
andmanagementofmulti-access-pointnetworks
• Secureguestaccesscreatesapartitionbetweenthevirtualguestnetworkand
thecorporateLAN.
• VoiceoverWLANoptimizationdeliversqualityofservice,calladmission
control,andfasthandoffsbetweenaccesspointstoimprovethequalityofa
wirelessvoiceinfrastructure.
58
HP ProCurve PoE and UC Switch Selection Guide
Fixed-Port
Modular
HP
ProCurve
switch
products
2520series
2610seriesand2615- 2910alseriesand
8-PoEswitch
2915-8G-PoEswitch
3500series
5400zlseries
8200zlseries
Ideal
environment
Idealforsmalland
growingbusinesses
seekingcosteffectiveswitches
withintegratedPoE
andmanagement
capabilities
Idealforenterprise
edge,remotebranch
offices,andconverged
networksrequiring
10/100accessspeeds
Idealforenterprise
edge,remotebranch
offices,andconverged
networksrequiring
Gigabitaccessspeeds
Idealforthose
seekingperformance,
security,mobility,and
convergencecapability
inastackableform
factor
Idealfor
environmentsdriven
byperformance,
security,mobility,
andconvergence
capability
Campuscore,
enterprisedistribution,
andmission-critical,
high-capacity,access
layerdeployments
Customers’
needs
•PoEcapabilityfor
poweringIPphones,
wirelessAPs,and/or
videocameras
•Managedswitchwith
Layer2functionality
witheitherGigabit
orFastEthernet
connectivity
•Optionalfiberuplink
capabilitywithSFP
slots
•Upto8or24portsof
PoEconnectivity
•Advanced
convergence
featuresfortoday’s
VoIP,wireless
networks,and
videosurveillance
functionallyat
wirespeed10/100
performance
•ScalablePoE
deployment
•Upto48portsof
PoEconnectivity
•Robustnetwork
connectivitywith
standards-based
10/100connectivity
withGigabituplinks
•Granularcontrolof
networkwithmore
accesssecurity,
PoE,andtraffic
monitoring
•Easyintegrationand
management
•Offersthemost
flexibleandeasyto-deployuplinksin
itsclass.Together
withstaticand
RIPIPv4routing,
robustsecurity
andmanagement,
enterpriseclass
features,freelifetime
warranty*,andfree
softwareupdates
•Cost-effective,
scalablesolution
forcustomers
whoarebuilding
high-performance
networks
•High-performance
Gigabitaccess
switch
•Fouroptional10Gigabitports(CX4
and/orSFP+)**
•IEEE802.3af/802.3at
functionality(PoE/
PoE+**)
•IPv6hostcapability
toprovidetransition
fromIPv4and
forwardingofIPv6
multicasttraffic
•Highlyscalable,
enterprise-class
switchesthat
supportawide
rangeofapplications
fromGigabittothe
desktop,PoEfor
IPphones,ACLfor
accesssecurity,and
virusthrottlingto
preventdowntime
•Granularcontrolof
networkuseraccess
andsecuritypolicy
tosecurecompany
informationassets
•Form-factorchoices
thatcanfitinto
differentnetwork
environmentswith
consistentfeatures,
capability,and
management
•SwitcheswithGigabit
interfaces,10-GbE
uplink,androom
forfuturesoftware
updates
•UpgradabletoVRRP
andOSPFfor
missioncriticalUC
deployments
•IPv6ready
•Common
softwarebasefor
3500/5400/8200
foreaseof
management
•Highlyscalable,
enterprise-class
switchesthat
supportawide
rangeofapplications
fromGigabittothe
desktop,PoEfor
IPphones,ACLfor
accesssecurity,and
virusthrottlingto
preventdowntime
•Granularcontrolof
networkuseraccess
andsecuritypolicy
tosecurecompany
informationassets
•Form-factorchoices
thatcanfitinto
differentnetwork
environmentswith
consistentfeatures,
capability,and
management
•SwitcheswithGigabit
interfaces,10-GbE
uplink,roomfor
futuresoftware
updates,and
scalabilitytodifferent
configurations
forinvestment
protection
•UpgradabletoVRRP
andOSPFfor
mission-criticalUC
deployments
•IPv6ready
•Common
softwarebasefor
3500/5400/8200
foreaseof
management
•Platformand
softwarehighavailabilityfeatures
•Comprehensive
hardwareand
softwarehighavailabilityfeatures
•Scalable,wire-speed
Gigabitandhigh
density10-GbE
connectivity
•Long-term
investment
protection
viasoftware
andhardware
upgradability
•Featureflexibility
(e.g.,QoScontrols,
GigabitPoE)to
enabledeployment
inawiderangeof
deploymentmodels
•Management
simplicityand
reducedcomplexity
•Form-factorchoices
thatcanfitinto
differentnetwork
environmentswith
consistentfeatures,
capability,and
management
Competitive
products
•NETGEARFSM72x/
GSM72xSeries
•D-LinkDES-3xxx/
DGS-3xxxSeries
•CiscoSmall
BusinessSRW
Series
•CiscoCatalyst
Express5xxSeries
•CiscoCatalyst2960
LANLiteSeries
•CiscoSmall
BusinessProESW
Series
•CiscoCatalyst2960
Series
•Nortel4500Series
•CiscoCatalyst3560
•CiscoCatalyst
&3750Series
2960GSeries
•Nortel4500GSeries •NortelEthernet
Switch5000Series
•ExtremeSummit
X450Series
•NETGEAR
GSM7312
•NETGEAR
GSM7324
**2910seriesonly
•D-LinkDGS-3300
Series
•D-LinkDXS-3300
Series
•CiscoCatalyst3560
&3750Series
•CiscoCatalyst4500
Series
•Extreme
BlackDiamond8800
•Extreme
BlackDiamond6808
•ExtremeSummit
X450Series
•FoundryFastIron
SuperX
•NortelEthernet
Switch5000
•NETGEAR
GSM7312,
GSM7324
•D-LinkDGS-3300
andDXS-3300
Series
•CiscoCatalyst6500
Series
•CiscoCatalyst4500
Series
•FoundryFastIron
SuperX
•Extreme
BlackDiamond8800
•NortelEthernet
RoutingSwitch8600
Series
59
HP ProCurve PoE and UC Switch Selection Guide
Fixed-Port
Subcategory
2520-8-PoE/
2520-24-PoE/
2520G-8-PoE/
2520G-24-PoE
2610-24/12PWR
2610-24-PWR/
2610-48-PWR
J9137A/ J9138A/
J9298A/ J9299A
J9086A
J9087A/
J9089A
3
3
3
3
PoE 10/100 ports
8/24/0/0
12 (of 24)
24/48
8
PoE 10/100/1000 ports
0/0/8/24
Feature
Product number
Ports, media, and
PoE
IEEE 802.3af Power over Ethernet
2615-8-PoE
IEEE 802.3at Power over Ethernet Plus
PoE/PoE+ 10/100 ports
PoE/PoE+ 10/100/1000 ports
Pre-standard PoE support
Maximum PoE power
3
3
3
67 W/ 195 W/ 67 W/ 195 W
125 W
377 W
533 W
785 W
Maximum PoE power with EPS
Uplink flexibility
67 W
HP ProCurve/IEEE Auto-MDIX
3
3
3
3
1-GbE 1000Base-T/Mini-GBIC
2/4/2/4 (3)
4
4
2
10-GbE ports
Module slots
Performance
Routing/Switching capacity
5.6/8.4/20/48 Gbps
12.8 Gbps
12.8/17.6 Gbps
5.6 Gbps
Security
Multi-user IEEE 802.1X (per port)
2
8
8
2
Multi-role access control (IEEE 802.1X,
MAC authentication, Web authentication)
3
3
3
3
Dynamic ARP protection
3
3
3
DHCP protection
3
3
3
Dynamic IP lockdown
3
Virus throttling
Management
HP ProCurve Manager Plus 3.0 support
3
3
3
3
3
3
3
Remote Intelligent Mirroring (based on
ACL, port, MAC, or VLAN)
RMON, XRMON, sFlow
IEEE 802.1AB Link Layer Discovery
Protocol (LLDP)
3
3
3
3
LLDP-MED (Media Endpoint Devices)
3
3
3
3
LLDP-MED fine-grained power control
3
3
3
3
RFC 4675 RADIUS VLAN for voice
Command authorization
Resilience and
high availability
Redundant switch fabric and
management module
Hot-swappable modules
Virtual Router Redundancy Protocol
QoS
IEEE 802.3ad Link Aggregation Control
Protocol (LACP) – links per trunk
8
8
8
8
ProCurve trunking – links per trunk
8
24
24
8
IEEE 802.1s Multiple Spanning Tree
Protocol (including STP, RSTP)
3
3
3
3
2 or 4
HW queues per port
Honor DSCP or IEEE 802.1p priority
Assign IEEE 802.1p priority
Remap DSCP
2 or 4
4
4
3
3
3
3
Classifier
Classifier
Classifier
Classifier
3
3
3
3
3
3
3
3
Guaranteed minimum bandwidth per port,
per queue
Prioritization by IP address and UDP/TCP
port ranges
Multicast
Data-Driven IGMP
PIM Multicast Routing
HP ProCurve Lifetime Warranty
Standards-based convergence features
PoE (IEEE 802.3af) & PoE+ (IEEE 802.3at) – Ethernet
with power, ideal for phones, cameras, and more
Wi-Fi WMM – wireless QoS enhancements to
support multimedia transport
LLDP-MED and RFC 4675 – automates configuration
of phones and network settings
802.11e APSD – allows wireless VoIP handsets to
support more efficient power management
LLDP-MED fine-grained power management – delivers 10-GbE uplink – aggregating to fast pipes ensures
just the right amount of PoE to save energy
optimal application performance
60
NAC/802.1X – identity-driven security at the edge of
the network where users connect
sFlow – standards-based sampling technology
allows monitoring of network performance
IGMP & PIM DM/SM – manages efficient delivery of
video and eliminates unnecessary network traffic
SVP – SpectraLink Voice Priority is an open,
straightforward voice QoS approach
• Next-business-day advance
replacement included free of
charge
• Free telephone and Web support
• Free software updates
HP ProCurve PoE and UC Switch Selection Guide
Modular
2910al-24G-PoE+/
2910al-48G-PoE+
2915-8G-PoE
J9146A/
J9148A
3
3
3500-24-PoE/
3500-48-PoE
3500yl-24G-PWR/
3500yl-48G-PWR
5406zl
5412zl
212zl/8206zl
J9471A/
J9473A
J8692A/
J8693A
J8697A
J8699A
J9447A
J8698A
J8700A
J9448A
J8715B/
J9475A
3
3
3
3
3
3
3
3
3
24/48
8
24/48
24/48
3
382 W
3
67 W
3
144 (2)
288 (2)
288/144 (2)
144 (2)
288 (2)
288/144 (2)
3
3
398 W
398 W
1800 W
3600 W
3600 W/1800 W
796 W
796 W
3600 W
5400 W
5400 W/3600 W
3
3
3
48/24
3
3
3
3
4/4 (3)
2
4/4 (3)
4/4 (3)
4
4
24
48
2
1
6
12
12/6
128/176 Gbps
20 Gbps
12.0/16.8 Gbps
101.8/149.8 Gbps
322.8 Gbps
645.6 Gbps
645.6/322.8 Gbps
8
2
32
32
32
32
32
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
8
24
3
3
3
3
3 (1)
3 (1)
3 (1)
3 (1)
3 (1)
8
8
8
8
8
8
8
36
36
36
36
36
3
3
3
3
3
3
8
2 or 4
8
8
8
8
8
3
3
3
3
3
3
3
Classifier
Classifier
Classifier
Classifier
Classifier
Classifier
Classifier
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
SM(1) & DM(1)
SM(1) & DM(1)
SM(1) & DM(1)
SM(1) & DM(1)
SM(1) & DM(1)
3
3
Why choose HP ProCurve?
(1) Requires premium license
Choice and flexibility – performance and interoperability
(2) 10/100 or 10/100/100 PoE/PoE+ modules
Advanced technology – 30 years of leadership
Security and trust – safe and field-tested solutions
Proven reliability – backed by a lifetime warranty
Return on IT investment – easy to install and use
(3) Dual-personality ports
For a complete list of these products’ features and
other HP ProCurve products, such as intelligent edge
switches and WAN, mobility, and network management,
please visit www.procurve.com/convergence
61
ANS - Adler Networking Solutions
ANS Cat. 6 Keystone Jack
ANS-504-180
ANS-504-110
ANS-504E
ANS-504S
CAT.6RJ45Keystonejack180degree
CAT.6RJ45Keystonejack90degree
CAT.6RJ45Tool-lesskeystonejack90degree
CAT.6RJ45Tool-lesskeystonejack90degree
ANS Cat. 6 Patch Panel
ANS-508-24K-C6
ANS-508-24PCB
CAT.6RJ4524PortRJ45patchpanel(6x4)
CAT.6RJ4524PortRJ45patchpanelPCBtype
ANS Cat. 5E Keystone Jack
ANS-505-WH
ANS-505-BL
ANS-505-OR
ANS-505-GR
ANS-505-YL
ANS-505-RE
ANS-505-BK
ANS-505-S
ANS-505-180
CAT.5ERJ45Keystonejackwhite
CAT.5ERJ45Keystonejackblue
CAT.5ERJ45Keystonejackorange
CAT.5ERJ45Keystonejackgreen
CAT.5ERJ45Keystonejackyellow
CAT.5ERJ45Keystonejackred
CAT.5ERJ45Keystonejackblack
CAT.5ERJ45Keystonejackshielded
CAT5.ERJ45Keystonejack180º
ANS Inline Couplers
ANS-350
ANS-350E8
ANS-350K8
ANS-350KS8
ANS-350G8
ANS-350KG8
ANS-350SG8
CAT.3Inlinecoupler
CAT.5EInlinecoupler
CAT.5ESnap-incoupler
CAT.5EShieldedsnap-incoupler
CAT.6Inlinecoupler
CAT.6Snap-incoupler
CAT.6Shieldedsnap-incoupler
ANS Cat. 5E UTP Patch Panel
ANS-508-16
ANS-508-24M
ANS-508-48M
CAT.5E16PortRJ45patchpanel(8x2)
CAT.5E24PortRJ45patchpanel(6x4)
CAT.5E48PortRJ45patchpanel(6x8)
ANS Cat. 5E STP Patch Panel
ANS-508S-16
ANS-508S-24
CAT.5ESTP16Portpatchpanel
CAT.5ESTP246Portpatchpanel
ANS Modular Plugs
62
ANS-RJ-45-x
ANS-RJ2-45-5
ANS-RJ2-45-2
ANS-RJ2-45-3
ANS-RJ-45-1
ANS-RJ2-45-1
ANS-RJ3-45-1
ANS-RJ-45
ANS-RJ2-45
ANS-RJ3-45
ANS-FRJ2-45
ANS-FRJ2-45-1
ANS-FRJ2-45-2
ANS-FRJ2-45-S
ANS-FRJ2-45-SD
RJ452Prong1pin3pcs
RJ452ProngYpin3pcs1.3.5.7pinup
RJ452ProngYpin2pcs1.3.5.7pinup
RJ452ProngYpin2pcs1.3.7pinup
RJ452Prong1pin2pcs
RJ452ProngYpin2pcs
RJ453ProngYpin2pcs
RJ452Prong1pin
RJ452ProngYpin
RJ453ProngYpin
RJ452Prong1pinstandard
RJ452ProngYpin2pcs
RJ453ProngYpin3pcs1.3.5.7pinup
RJ452ProngYpinshortbody
RJ452ProngYpinshortbody1.3.5.7pinup
FibreNet® Fibre Optic Cables
PEOuterJacket
FlexibleStrengthElements
6.0mmBufferTube
SuperLAN Cable
2-96FibreConstruction,CentralTube
with12-fibreBundles
RipcordforJacketAccess(2)
Gel
FibreBinderThreads
250micronFibres
PEOuterJacket
Ripcord(1)
StrengthElements
Binder
WaterSwellableTape
Heavy Duty Duct Cable
2-288FibreConstruction,Stranded
LooseTubewith12-fibreSubunits
3.0mmGelFilledBufferTubes
Binder
250micronFibres
FRPStrengthMember
PEOuterJacket
AramidStrengthElements
Ripcord(1)
Binder
WaterSwellableTape
3.0mmGelFilledBufferTubes
Binder
250micronFibres
FRPStrengthMember
PEOuterJacket
SteelArmor
RipcordforJacketAccess(2)
All-Dielectric Self
Supporting ADSS Cable
2-60FibreConstruction,Stranded
LooseTubewith12-fibreSubunits
SHORTSPANSofupto249meters
ArmoTube Cable
2-96FibreConstruction,CentralTube
with12-fibreBundles
6.0mmBufferTube
RipcordforArmorAccess(2)
Gel
FiberBinderThreads
250micronFibres
PEOuterJacket
SteelTapeArmoring
WaterBlockingTape
PEInnerJacket
Ripcord(2)
StrengthElements
Binder
WaterBlockingTape
Ripcord(1)
Binder
3.0mmGelFilledBufferTubes
250micronFibres
DielectricStrengthMember
PEOuterJacket
SteelTapeArmoring
WaterBlockingTape
PEInnerJacket
SteelTapeArmoring
Ripcord(2)
WaterBlockingTape
PEInnerJacket
StrengthElements
Binder
Ripcord(2)
Binder
WaterBlockingTape
Ripcord(1)
3.0mmGelFilledBufferTubes
FRPStrengthMember
250micronFibres
Corrugate Steel Tape (CST) Cable
2-288FibreConstruction,Stranded
LooseTubewith12-fibreSubunits
Double Corrugate Steel
Tape (CST) Cable
2-288FibreConstruction,Stranded
LooseTubewith12-fibreSubunits
63
FibreNet® Connectors & Adaptors
ST Connector
Utilize a bayonet style mating concept to provide a secure,
robust coupling mechanism. The enclosed spiral slotted
coupling nut allows easy insertion in densely packed patch
panels. The ST connector has been used extensively in
telecom,dataandpremiseinstallationapplicationsandcould
easilybeconsideredadefactostandard.
ST Adaptor
• STtypefiberopticadaptorforconnectorwithST/PC
patchcord.
SC Connector
Utilize a push pull retention feature enabling easy insertion
andremoval,makingitideallysuitedforhighdensity.
The SC connector features an internal cavity that virtually
eliminatesthepossibilityofimproperepoxyapplication,thus
providinghighermanufacturingyields.
SC Adaptor
SC Simplex SM Adaptor
SC Duplex MM Adaptor
LC Connector
These connectors utilize the familiar RJ-45 style latching
mechanism.Asasmallformfactor(SFF)connector,theLC
connectorisalmosthalfthesizeofthepopularSCconnector.
With accelerated growth demanding greater bandwidth in
lessphysicalspace,LCconnectorshaveemergedasaviable
solutionforhighdensityframesandpatchpanels.
LC Adaptor
64
Proudly South African Certification
65
SABS Certification
66
SABS Power Duct Certificate
67
Glossary
EIA/TIA
ElectronicIndustriesAllianceandtheTelecommunicationsIndustryAssociation.
FDDI
FibreDistributedDataInterface.LANstandard,definedbyANSIX3T9.5,specifyinga100Mbpstoken-passingnetworkusingfibre-opticcable,withtransmissiondistancesofupto2km.
FDDIusesadual-ringarchitecturetoprovideredundancy.ComparewithCDDIandFDDIII.
FibreOptics
Amethodforthetransmissionofinformation(audio,video,data).Lightismodulatedand
transmittedoverhighpurity,hair-thinfibresofglass.Thebandwidthcapacityoffibreopticcable
ismuchgreaterthanthatofconventionalcableorcopperwire.
FibrePlant
Aerialorburiedfibreopticcablethatestablishedconnectivitybetweenfibreoptictransmission
equipmentlocations.
FIA
FibreopticIndustryAssociation.
(FIA)CDT
FibreCertifiedDesignTechnician.
(FIA)CDS
FibreCertifiedDesignSpecialist.
Hub
1.Generally,atermusedtodescribeadevicethatservesasthecenterofastar-topology
network.
2.Hardwareorsoftwaredevicethatcontainsmultipleindependentbutconnectedmodulesof
networkandinternetworkequipment.Hubscanbeactive(wheretheyrepeatsignalssent
throughthem)orpassive(wheretheydonotrepeat,butmerelysplit,signalssentthrough
them).
3.InEthernetandIEEE802.3,anEthernetmultiportrepeater,sometimescalleda
concentrator.
ISO
InternationalOrganisationforStandardisation.Internationalorganisationthatisresponsible
forawiderangeofstandards,includingthoserelevanttonetworking.ISOdevelopedtheOSI
referencemodel,apopularnetworkingreferencemodel.
ISO9000
Setofinternationalquality-managementstandardsdefinedbyISO.Thestandards,whichare
notspecifictoanycountry,industry,orproduct,allowcompaniestodemonstratethattheyhave
specificprocessesinplacetomaintainanefficientqualitysystem.
Multiplexing
Schemethatallowsmultiplelogicalsignalstobetransmittedsimultaneouslyacrossasingle
physicalchannel.Comparewithdemultiplexing.
Network
Anetworkisgroupoftwoormorecomputersorcomputersystemslinkedtogether.Thereare
manytypesofcomputernetworks,including:
Switch
LANs(local-areanetworks):
Thecomputersaregeographicallyclosetogether(thatis,inthe
samebuilding)
WANs(wide-area
networks):
Thecomputersarefartherapartandareconnectedbytelephone
linesorradiowaves.
CANs(campus-area
networks):
Thecomputersarewithinalimitedgeographicarea,suchasa
campusormilitarybase.
MANs(metropolitan-area
networks):
Adatanetworkdesignedforatownorcity.
HANs(home-area
networks):
Anetworkcontainedwithinauser’shomethatconnectsa
person’sdigitaldevices.
1. Networkdevicethatfilters,forwards,andfloodsframesbasedonthedestinationaddressof
eachframe.TheswitchoperatesatthedatalinklayeroftheOSImodel.
2. Generaltermappliedtoanelectronicormechanicaldevicethatallowsaconnectiontobe
establishedasnecessaryandterminatedwhenthereisnolongerasessiontosupport.
3. Intelephony,ageneraltermforanydevice,suchasaPBX,thatconnectsindividualphones
tophonelines.SeealsoPBXandPSTN.
UL
UnderwritersLaboratories.IndependentagencywithintheUnitedStatesthattestsproduct
safety.
20-AmpPowerInput
Support
20-ampPowerInputSupport.IEC320/C20powerinletreceptaclessupportsanypowercord
withIEC320/C19powerconnector(PTCORD-XX).
3PhasePower
3phasepowerdistributionforhigh-density,high-powerdemandequipmentcabinets.Input
currentmonitoringofeachphaseallowsforproperloadbalancingofeachrackmountpower
distributionunit.SwitchedunitsprovideremotepowermanagementwhileSmartunitsprovide
remotepowermonitoringandMeteredunitsprovidelocalinputcurrentmonitoring.
The-3Phextensiononaproductindicatesa3Phasepowerproduct.
3-PhaseDelta/3~Delta
68
3~Deltaproductsdifferfrom3~Wyeproductinthattheyhaveonly4conductorsinsideofthe
cord,thereisno“neutral”conductorinaDeltaconfiguration.Thus,3~Deltaproductsareonly
capableofdelivering250Vpoweroutput.
Glossary
3-PhaseWye/3~Wye
3~Wyeproductisa5cordconfigurationwiththree“hot”wires,one“neutral”wireandone
“ground”wire.Theneutralconductorfoundin3~Wyecordsallowstheoutputof110Vand/or
220V;thisoptionallowscabinetpowerdistributionunitconfigurationforeithervoltageswhichis
popularinDataCenterenvironmentsduetoequipmentdemands.
30AmpPowerInput
Support
30-amppowerinputsupportprovideshard-wired10’cordandappropriateL5-30orL6-30plug
type.
AC-AlternatingCurrent
AC(alternatingcurrent)referstowhentheflowofelectricchargeperiodicallyreverses
direction.Anelectricchargewouldforinstancemoveforward,thenbackward,thenforward,
thenbackward,overandoveragain.
Amps
AmperesorAmpsareastandardmeasurementofelectricalcurrentforhowmuchelectricityis
movingthroughawireatasettime.Theampdrawiscalculatedbytheelectricalrequirements
ofthedevicespluggedin,andisregulatedbyacircuitbreakerorfuse.
ApparentPower
ApparentPoweristheproductofroot-mean-square(rms)voltagemultipliedbyrmscurrentand
themeasurementbywhichpowercompaniesbill.
BranchCircuitProtection SentryPDUsaresafety-agencycertifiedtothenewUL60950-1standard(CSA/UL/TUV)&the
NationalElectricalCode(NEC),whichrequirebranchcircuitprotectionforreceptacles.
CircuitBreaker
ProtectedOutlets
Poweroutletprotectionprovidedbythermalcircuitbreaker.
CrestFactor
Crestfactoristheratiobetweentheinstantaneouspeakcurrentrequiredbytheloadandthe
RMScurrent.
Highcrestfactorcanleadtooverheatingofpowersupplycomponents.
DataCenter
InfrastructureEfficiency
(DCiE)
DCiEisthereciprocalcalculationofPUE.
DC-DirectCurrent
Indirectcurrent(DC),theflowofelectricchargeisonlyinonedirection.Thisisincontrastto
ACoralternatingcurrent.
FuseProtectedOutlets
PowerOutletprotectionprovidedbyfuses.
High-AmpIn-Rush
Protection
High-AmpIn-rushrelaysaccommodatetheextremelyhighpowerin-rushspikesfromtoday’s
switchingpowersupplies.
IEC
InternationalElectrotechnicalCommissionhasasetofstandardreceptaclesandoutlets.
PopularizedbecauseIECplugscanoutputeither125voltsor250voltsaccordingtothecord
thatispluggedintothem.ConfigurationsmostcommonlyusedinDataCenterOperations
includeC13toC14adnC19toC20.
IntegratedTemp/
HumidityProbes
Two(2)RJ-styleconnectorslocatedonthefacepanelofthePDUsenclosureprovidesupport
fortwo(2)IntegratedTemperature&HumidityProbeswithten-foot(10’)cablestoproviderealtimemeasurementsinthedatacentercabinet.
LDAP/LDAPS
ThesentryfamilyofproductssupportsLightweightDirectoryAccessProtocol(LDAP)Version3
includingLDAPS(LDAPoverTSL/SSL).ThissupportenableauthenticationwithLDAPservers;
useraccountsdonotneedtobeindividuallycreatedlocallyoneachSentrydevice.
1/PUE=(ITEquipmentPowerx100%)/TotalFacilityPower
Thisallowsadministratorstopre-defineandconfigure(ineachSentryproduct,andintheLDAP
server)asetofnecessaryLDAPgroups,andaccessrightsforeach.User’saccessrightscan
thenbeassignedorrevokedsimplybymakingtheuseramemberofoneormorepre-defined
SentryLDAPgroups.Useraccountcanbeadded,deleted,orchangedintheLDAPserver
withoutanychangesonindividualSentryproducts.
SentryLDAPsupporthasbeentestedinthefollowingenvironments:
-MicrosoftActiveDirectory(MSAD)
-NovelleDirectory(eDir)
-OpenLDAP
LEDDigitalDisplayInput EasyviewingdisplayonthefaceoftheenclosurethatreportstheTrueRMSPowerMonitoring
CurrentMonitor
oftheaggregateloadonthepowercircuit(inamps).
TheInputCurrentDisplayallowsinstallationengineerstoverifythereal-timecurrentdrawon
thepowercircuit.
Thiseliminatestheguessworkofestimatingthecurrentdrawandpreventsthecostlymistake
of:1)overestimatingandrequiringextrapowerdropsinstalledor2)underestimatingand
overloadingacircuit-puttingtheentercabinetatriskifacircuitbreakeratthemaincabinet
PDUtrips.
LoadSense-Input
CurrentMonitorPer
Outlet
Individualinputcurrentmonitoring(“LoadSense”)providesreal-timepowermeasurementof
theloadinampsoneachpowerinlet,accessibleviafirmwareinterface.
69
Glossary
MultipleConcurrent
Users
MultipleconcurrentusersallowsseveraluserstobeloggedintoaSentryatthesametime.In
thisway,differentusers,withaccessrightstoonlytheirequipment,canreboottheirdevice(s)
whentheyneedto,withoutwaitingforanotherusertologoutoftheSentryunit.
NEBSCompliant
MeetsNEBSLevelOneandLevelThreerequirementsforco-locationinaBellCore(Telcordia)
centraloffice.
NEMA
NationalElectricalManufacturersAssociationsetofstandardplugsandreceptacles.NEMA
nomenclatureaddressesthepartconfigurationbylockingability(ifapplicable),5for125V,6
for250Volt,dash(-),followedbytheamperagerating(20A,30A)andaPforplugorRfor
receptacle.
I.E.5-20Risa125Vtwistlockreceptaclefor20Amps.
POPS-PerOutlet
PowerSensing
PerOutletPowerSensingPDUsprovideinformationperindividualoutletincludes:currentload
(A),voltage(V),power(kW),apparentpower(VA),crestfactor,andpowerfactor.Usingour
groupingtechnology,powerinformationisavailableperdevice,groupsofdevices(application),
individualCabinetPDUorcabinet.
Power(kW)
Timerateofdoingwork,usuallyexpressedinhorsepowerorwatts.
PowerFactor
PowerFactoristheratioofRealPowertoApparentPower.
APowerFactorof100%indicatesperfectpower,whilelowervaluesindicatethatthecircuitis
wastingenergy.
PUE-PowerUsage
Effectiveness
PUE=TotalFacilityPower/ITEquipmentPower
RealPower
RealPoweristheRMSvalueofWatts.
RealPowerdividedbyApparentPowerisameasurementoftheefficiencyofpowerusageona
circuit.
RedundantPower
ProvidingtwoindependentpowersourcesforcriticalequipmenttoensureUptime.Froma
cabinetPDUthiscanbeaccomplishedbyadualcircuitcabinetpowerdistributionunitwith
eachcordpluggedintoaseparatepowersource,orbypowering2PDUswithdifferentpower
sources(separateUPS,aUPSandagenerator,etc.)
SinglePhasePower-1
PhasePower
Distributionofalternatingcurrentelectricpowerusingasysteminwhichallthevoltagesofthe
supplyvaryinunison.Single-phasedistributionisusedwhenloadsaremostlylightingand
heating,withfewlargeelectricmotors.
Asingle-phasesupplyconnectedtoanalternatingcurrentelectricmotordoesnotproducea
revolvingmagneticfield;single-phasemotorsneedadditionalcircuitsforstarting,andsuch
motorsareuncommonabove10or20kWinrating.
SNMPManagement
TheSentryfamilyofproductssupportstheSimpleNetworkManagementProtocol(SNMP).
ThisallowsnetworkmanagementsystemstouseSNMPrequeststoretrieveinformationand
controlpowerfortheindividualoutlets.TheSentryincludesanSNMPv1agentsupporting
standardMIBIandMIBIIobjects.AprivateenterpriseMIBextension(Sentry3MIB)isalso
supportedtoprovideremotepowercontrol.
TrueRMSInputCurrent
Monitoring
InputCurrentMonitoringinSentrypowerproductsisreportedasthecumulativeload(inamps)
oneachpowercircuitsothatdatacentermanagerscanobtainthedatatheyneedtoplantheir
powerrequirementsandtomonitorpowertotheirITequipment.InputCurrentisreportedin
AmpsandcanbeviewedlocallyontheenclosureviaanLEDDigitalDisplayandremotely,
whenapplicable,viathefirmwareinterface.
Voltage
VoltageisalsoreferredtoasElectricaltensionandmeasureinitsSIunit,thevolt.Voltageis
thedifferenceofelectricalpotentialbetweentwopointsofanelectricalorelectroniccircuit.
Volts
Afixedvalueforacircuitthatisameasurementofelectricalpotential.
Watts
Measurementofelectricalpowerbeingutilizedbyasystem.
ThesimplestcalculatedofaWattisoneAmpmultipliedbyelectricalpotentialofoneVolt.
TrusRMScalculationstakenintoconsiderationthephasesofthevoltage,andshapeofthe
currentwavestoacircuitinordertoprovidethepowerreading.DifferencebetweentheRMS
wattvalueandthecalculationofVoltsmultipliedbyAmpsindicatesaninefficiencyinhow
powerisdeliveredorconsumedbythecircuit.
70
IP54Rated
Limitedingressofdustpermitted(noharmfuldeposit).Protectedagainstwatersplashedfrom
alldirections.Limitedingresspermitted.
IP65Rated
Totallyprotectedagainsttheingressofdustandprotectedagainstjetsofwater.Limitedingress
permitted.
IP66Rated
TotallyprotectedagainsttheingressofdustandProtectedagainststrongjetsofwater.Limited
ingresspermitted.
Glossary
Topology - Figure 1
AWG Wire Sizes (see sample table)
IntheAmericanWireGauge(AWG),diameterscanbecalculatedbyapplyingtheformulaD(AWG)=.005·92((36AWG)/39)inch.Forthe00,000,0000etc.gaugesyouuse-1,-2,-3,whichmakesmoresensemathematically
than“doublenought.”ThismeansthatinAmericanwiregageevery6gaugedecreasegivesadoublingofthewire
diameter,andevery3gaugedecreasedoublesthewirecrosssectionalarea.JustlikedBinsignallevels.
Metric Wire Gauges
IntheMetricGaugescale,thegaugeis10timesthediameterinmillimetres,soa50gaugemetricwirewould
be5mmindiameter.NotethatinAWGthediametergoesupasthegaugegoesdownmetricistheopposite.
Probablybecauseofthisconfusion,mostofthetimemetricsizedwireisspecifiedinmillimetresratherthanmetric
gauges.
AWG (American Wire Gauge) Sample Table
AWG Gauge
Diameter mm
Ohms/km
AWG Gauge
Diameter mm
Ohms/km
14
15
1.62814
8.282
23
0.57404
66.7808
1.45034
10.44352
24
0.51054
84.1976
16
1.29032
13.17248
25
0.45466
106.1736
17
1.15062
16.60992
26
0.40386
133.8568
18
1.02362
20.9428
27
0.36068
168.8216
19
0.91186
26.40728
28
0.32004
212.872
20
0.8128
33.292
29
0.28702
268.4024
21
0.7239
41.984
30
0.254
338.496
22
0.64516
52.9392
31
0.22606
426.728
71
Notes
72
Notes
73
DISTRIBUTED BY
Head Office, Johannesburg
51-57 Gibbs Road
Devland 1813
Johannesburg
South Africa
Tel (S-board): +27 (0) 11 983 7000
Fax : +27 (0) 11 938 9895 E-mail: info@adlerac.co.za
www.adlerac.co.za
0861 ADLERAC (2353722)
Download