CATALOGUE Data Center Racks Power Management Co-Location Racks KVM Solutions IP Cabinets Switching Solutions EV Cabinets Environmental Monitoring Summer Edition 2011 Contents Introduction 1 WallMount Boxes 2 Server Racking Solutions 4 IP Rated Racking Solutions 13 Co-Location Cabinets 16 ETSI Cabinets 20 Custom Racking Solutions 21 Rack Accessories 22 Adler Power Solutions® 23 The IP-EV Bio Unit Closure 26 Environmental Racking – EV Rack® EV-Rack® Anatomy 28 EV-Rack®Configuration 29 EV-Rack®AccessControl–Suprema 30 EV-Rack®ThermalManagement–Panasonic 31 EV-Rack®FireSuppression–PanelSafe® 32 EV-Rack Monitoring–Geist 33 Data Center KVM Solutions – ATEN DataCenterKVMSolutionGuide 34 KVMSolutions–ATEN 36 Geist® Monitoring Solution AdleRac®In-LinePowerMonitoringSolutions 41 AdleRac Local&RemoteCurrentMonitoring 42 AdleRac BasicLocalPower&CurrentMonitoring 43 RacSense VariableSpeedFanController 44 ® ® ® ® Power Management – Server Technology ServerTechnology®PowerDistributionUnits 46 Network Switches Cisco®Switches 55 Cisco®MobilityExpress 58 HP ProCurve PoE and UC Switch Selection Guide 59 ANS – Adler Networking Solutions® 62 FibreNet® Fibre Optic Cables 63 FibreNet® Connectors and Adaptors 64 Proudly South African Certification 65 SABS Certification 66 Glossary 68 Summer Edition 2011 Introduction DESIGNERS, MANUFACTURERS AND SUPPLIERS OF DATA CENTER RACKING SOLUTIONS AdleRac®isspecialisedincabinetsandenclosuresforITinfrastructureintheDataCentreandTelecommarkets. AdleRac®cabinetsolutionsareidealforservers,networkcomponentsandcablinginfrastructure.Thecabinetsare modular,sotheycanbeadaptedeasilytochanginghardwareconfigurations. With over 18 years of industry experience, AdleRac® delivers a structural contribution of superior quality for tomorrow’sITinfrastructure. AdleRac®hashelditsSABS ISO 9001:2008accreditationforthelast16yearsandworksaccordingtothese standardstodeliverasuperiorlevelofquality.Thisensuresthatyouhaveafullyintegratedcabinetsolutionfor yourITinfrastructureatyourdisposalatalltimes,builtaccordingtothelatestspecificationsoftheTIA-310-D standards. AdleRac®willalwaysprovideafullyintegratedcabinetsolutionforyourITinfrastructurewhichisdurableandof highqualitythatguaranteesoptimalefficiencyandsustainedperformance AdleRac®playsaleadingroleasaProudlySouthAfricanmanufactureroffuture-proofcabinetsolutions. 1 WallMount Boxes Key Features Glassdoor Depthadjustable punchedprofiles Fanknock-out • • • • • • • • 19”wallmountingbox Fabricatedfromsheetmetal Epoxypowdercoated Adjustable(fordepth)punchedprofiles Convenientlypositionedfancut-outs Cableentrycut-outs(100mmx40mm)topandbottom Standardwithlockableglassdoor AdleRac®isanSABSISO9001:2008certifiedmanufacturer Options • 100mmswingframecollar(foraccesstorearofbox) • 200mmswingframecollar(foraccesstorearofbox) • Removablesidepanel(specialrequest) Cableentry 100mmwallboxswingframecollar 200mmwallboxswingframecollar 4U 19” Steel Wallbox Part No. Part No. with 100mm collar Part No. with 200mm collar 1R03-04UWB/GG 1R03-04UWBS1GG 1RWBST-304 Description Height 19”4Ux 220mm 300mmwallbox 6U 19” Steel Wallbox Part No. Part No. with 100m m collar Part No. with 200mm collar 1R04-06UWB/GG 1R04-06UWBS1GG 1R04-06UWBS2GG 2 Description Height 19”6Ux 310mm 400mmwallbox WallMount Boxes 9U 19” Steel Wallbox Part No. Part No. with 100mm collar Part No. with 200mm collar 1R04-09UWB/GG 1R04-09UWBS1GG 1R04-09UWBS2GG Description Height 19”9Ux 440mm 400mmwallbox 12U 19” Steel Wallbox Part No. Part No. with 100mm collar Part No. with 200mm collar 1R04-12UWB/GG 1R04-12UWBS1GG 1R04-12UWBS2GG Description Height 19”12Ux 575mm 400mmwallbox 15U 19” Steel Wallbox Part No. Part No. with 100mm collar Part No. with 200mm collar 1R04-12UWB/GG 1R04-12UWBS1GG 1R04-12UWBS2GG Description Height 19”15Ux 710mm 400mmwallbox 20U 19” Steel Wallbox Part No. Part No. with 100mm collar Part No. with 200mm collar 1R04-20UWB/GG 1R04-20UWBS1GG 1R04-20UWBS2GG Description Height 19”20Ux 930mm 400mmwallbox 3 Server Racking Solutions AdleRac® 10U Server Rack Key Features •Flexibleandmodularrackingsystem •Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor •Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 •AdleRac®isanSABSISO9001:2008certifiedmanufacturer Gold Range GoldRange 10U600mmx600mm The Gold Range from AdleRac® is its most popular rack and is the stalwart in the range. This popular rack was designed to industry standard DIN41494 specifications. Its frame is constructed from toughened lightweight extruded aluminium and finished with stylish and distinctive detailing.This compact rack is extremely modular in design and thus offers customers freedom of installed equipmentandexceptionaleaseofuse. FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range • This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements PlatinumRange 10U600mmx1m • The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. Technical Specifications 4 Rack Height 10U 600 x 600 mm 600 x 800 mm 600 mm x 1,0 m NetWeight 30KG 32.2KG 38KG MaximumHeight 650mm 650mm 650mm MaximumWidth 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm ShippingWeight 60KG 62.2KG 68KG ShippingHeight 680 mm 680 mm 680 mm ShippingWidth 630 mm 630 mm 630 mm ShippingDepth 630 mm 830 mm 1030 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm Color BlackorGrey BlackorGrey BlackorGrey Server Racking Solutions AdleRac® 13U Server Rack Key Features •Flexibleandmodularrackingsystem •Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor •Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 •AdleRac®isanSABSISO9001:2008certifiedmanufacturer Gold Range The Gold Range from AdleRac® is its most popular rack and is the stalwart in the range. This popular rack was designed to industry standard DIN41494 specifications. Its frame is constructed from toughened lightweight extruded aluminium and finished with stylish and distinctive detailing.This compact rack is extremely modular in design and thus offers customers freedom of installed equipmentandexceptionaleaseofuse. GoldRange 13U600mmx600mm FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range •This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. PaltinumRange 13U600mmx1m Technical Specifications Rack Height 13U 600 x 600 mm 600 x 800 mm 600 mm x 1,0 m NetWeight 38.2KG 40KG 44.2KG MaximumHeight 795mm 795mm 795mm MaximumWidth 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm ShippingWeight 68.2KG 70KG 74.2KG ShippingHeight 825mm 825mm 825mm ShippingWidth 630 mm 630 mm 630 mm ShippingDepth 630 mm 830 mm 1030 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm Color BlackorGrey BlackorGrey BlackorGrey 5 Server Racking Solutions AdleRac® 20U Server Rack Key Features •Flexibleandmodularrackingsystem •Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor •Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D 1992 •AdleRac®isanSABSISO9001:2008certifiedmanufacturer Gold Range GoldRange 20U600mmx600mm The Gold Range from AdleRac® is its most popular rack and is the stalwart in the range. This popular rack was designed to industry standard DIN41494 specifications. Its frame is constructed from toughened lightweight extruded aluminium and finished with stylish and distinctive detailing.This compact rack is extremely modular in design and thus offers customers freedom of installed equipmentandexceptionaleaseofuse. FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range •This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements PlatinumRange 20U600mmx1m •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. Technical Specifications 6 Rack Height 20U 600 x 600 mm 600 x 800 mm 600 x 1,0 m NetWeight 55.2KG 57KG 61.2KG MaximumHeight 1100 mm 1100 mm 1100 mm MaximumWidth 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm ShippingWeight 85.2KG 87KG 115KG ShippingHeight 1130 mm 1130 mm 1130 mm ShippingWidth 630mm 630mm 630mm ShippingDepth 630 mm 830 mm 1030 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm Color BlackorGrey BlackorGrey BlackorGrey Server Racking Solutions AdleRac® 25U Server Rack Key Features •Flexibleandmodularrackingsystem • Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor • Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 •AdleRac®isanSABSISO9001:2008certifiedmanufacturer GoldRange 25U600mmx600mm Gold Range The Gold Range from AdleRac® is its most popular rack and is the stalwart in the range. This popular rack was designed to industry standard DIN41494 specifications. Its frame is constructed from toughened lightweight extruded aluminium and finished with stylish and distinctive detailing.This compact rack is extremely modular in design and thus offers customers freedom of installed equipmentandexceptionaleaseofuse. FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range • This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. PlatinumRange 25U600mmx1m Technical Specifications Rack Height 25U 600 x 600 mm 600 x 800 mm 600 x 1,0 m 600 x 1,2 m NetWeight 59.2KG 74.2KG 95.2KG 98.2KG MaximumHeight 1350mm 1350mm 1350mm 1350mm MaximumWidth 600 mm 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm 1200 mm ShippingWeight 89.2KG 104.2KG 125.2KG 128.2KG ShippingHeight 1380mm 1380mm 1380mm 1380mm ShippingWidth 630 mm 630 mm 630 mm 630 mm ShippingDepth 630 mm 830 mm 1030 mm 1230 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm 1000 mm Color BlackorGrey BlackorGrey BlackorGrey BlackorGrey 7 Server Racking Solutions AdleRac® 34U Server Rack Key Features •Flexibleandmodularrackingsystem •Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor •Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 GoldRange 34U600mmx600mm •AdleRac®isanSABSISO9001:2008certifiedmanufacturer Gold Range TheGoldRangefromAdleRac®isitsmostpopularrackandisthestalwartinthe range.ThispopularrackwasdesignedtoindustrystandardDIN41494specifications. Itsframeisconstructedfromtoughenedlightweightextrudedaluminiumandfinished with stylish and distinctive detailing. This compact rack is extremely modular in designandthusofferscustomersfreedomofinstalledequipmentandexceptional easeofuse. FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range •This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements PlatinumRange 34U600mmx1m •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. Technical Specifications 8 Rack Height 34U 600 x 600 mm 600 x 800 mm 600 x 1,0 m NetWeight 65KG 81.6KG 84.6KG MaximumHeight 1720mm 1720mm 1720mm MaximumWidth 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm ShippingWeight 95KG 111.6KG 114.6KG ShippingHeight 1750mm 1750mm 1750mm ShippingWidth 630 mm 630 mm 630 mm ShippingDepth 630 mm 830 mm 1030 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm Color BlackorGrey BlackorGrey BlackorGrey Server Racking Solutions AdleRac® 38U Server Rack Key Features •Flexibleandmodularrackingsystem •Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor •Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 GoldRange 38U600mmx600mm •AdleRac®isanSABSISO9001:2008certifiedmanufacturer Gold Range TheGoldRangefromAdleRac®isitsmostpopularrackandisthestalwartinthe range.ThispopularrackwasdesignedtoindustrystandardDIN41494specifications. Itsframeisconstructedfromtoughenedlightweightextrudedaluminiumandfinished with stylish and distinctive detailing. This compact rack is extremely modular in designandthusofferscustomersfreedomofinstalledequipmentandexceptional easeofuse. FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range • This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. PlatinumRange 38U600mmx1m Technical Specifications Rack Height 38U 600 x 600 mm 600 x 800 mm 600 x 1,0 m NetWeight 84.4KG 88.2KG 92.4KG MaximumHeight 1900mm 1900mm 1900mm MaximumWidth 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm ShippingWeight 114.4KG 118.2KG 168.18KG ShippingHeight 1930mm 1930mm 1930mm ShippingWidth 630 mm 630 mm 630 mm ShippingDepth 630 mm 830 mm 1030 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm Color BlackorGrey BlackorGrey BlackorGrey 9 Server Racking Solutions AdleRac® 43U Server Rack Key Features •Flexibleandmodularrackingsystem •Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor •Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 GoldRange 43U600mmx600mm •AdleRac®isanSABSISO9001:2008certifiedmanufacturer Gold Range The Gold Range from AdleRac® is its most popular rack and is the stalwart in the range. This popular rack was designed to industry standard DIN41494 specifications. Its frame is constructed from toughened lightweight extruded aluminium and finished with stylish and distinctive detailing.This compact rack is extremely modular in design and thus offers customers freedom of installed equipmentandexceptionaleaseofuse. FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range •This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements PlatinumRange 43U600mmx1m •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. Technical Specifications 10 Rack Height 43U 600 x 600 mm 600 x 800 mm 600 x 1,0 m 600 x 1,2 m NetWeight 103.2KG 107.4KG 109.2KG 111.3KG MaximumHeight 2120 mm 2120 mm 2120 mm 2120 mm MaximumWidth 600 mm 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm 1200 mm ShippingWeight 133.2KG 137.4KG 139.2KG 141.8KG ShippingHeight 2150mm 2150mm 2150mm 2150mm ShippingWidth 630 mm 630 mm 630 mm 630 mm ShippingDepth 630 mm 830 mm 1030 mm 1230 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm 1000 mm Color BlackorGrey BlackorGrey BlackorGrey BlackorGrey Server Racking Solutions AdleRac® 47U Server Rack Key Features •Flexibleandmodularrackingsystem •Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills •Raisedtopforventilation •Adjustablefeet(levellingscrews) •Hingedandremovablemetalsidepanelsandreardoor •Hingedandremovableglassfrontdoor •Fullrangeofaccessoriesavailable •Arangeofstandardsizesandvariantsavailable •Adjustabledepthreducers •Adjustablepunchedprofiles •Allmetalcomponentsareepoxypowdercoated •CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 GoldRange 47U600mmx600mm •AdleRac®isanSABSISO9001:2008certifiedmanufacturer Gold Range The Gold Range from AdleRac® is its most popular rack and is the stalwart in the range. This popular rack was designed to industry standard DIN41494 specifications. Its frame is constructed from toughened lightweight extruded aluminium and finished with stylish and distinctive detailing.This compact rack is extremely modular in design and thus offers customers freedom of installed equipmentandexceptionaleaseofuse. FeaturesincludeaqualitySABSapprovedsmokedandtoughenedglassdoorwith lock;hingedsidepanelsstrengthenedbyitsdoublebentedgesandweldedcorners; raisedtopforventilation;depthreducers;punchedprofiles,andadjustablefeet. Platinum Range •This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. PlatinumRange 47U600mmx1m Technical Specifications Rack Height 47U 600 x 600 mm 600 x 800 mm 600 x 1,0 m 600 x 1,2 m NetWeight 149KG 151KG 166KG 170.2KG MaximumHeight 2300 mm 2300 mm 2300 mm 2300 mm MaximumWidth 600 mm 600 mm 600 mm 600 mm MaximumDepth 600 mm 800 mm 1000 mm 1200 mm ShippingWeight 143.2KG 147.4KG 149.2KG 151.8KG ShippingHeight 2330 mm 2330 mm 2330 mm 2330 mm ShippingWidth 630 mm 630 mm 630 mm 630 mm ShippingDepth 630 mm 830 mm 1030 mm 1230 mm WeightCapacity(staticload) 1363.64KG 1363.64KG 1363.64KG 1363.64KG WeightCapacity(dynamicload) 1022.73KG 1022.73KG 1022.73KG 1022.73KG MinimumMountingDepth 262.00mm 262.00mm 262.00mm 262.00mm MaximumMountingDepth 450mm 650mm 800 mm 1000 mm Color BlackorGrey BlackorGrey BlackorGrey BlackorGrey 11 Server Racking Solutions 24” Data Centre Racking Key Features • Flexibleandmodularrackingsystem • Sturdyaluminiumuprightsonauniquelyrigidsetofmetalinfills • Internallyreducedto19” • Perforatedfrontandreardoors. • Easytojoinandbaying. • Raisedtopforventilation • Adjustablefeet(levellingscrews) • Hingedandremovablemetalsidepanelsandreardoor • Splitfrontandreardoors • Additional100mmoneithersideforCableManagement • Cableentrymadepossiblefromtoporbottom • Fullrangeofaccessoriesavailable. • Fittedwithhightensilesecurity“combinationlock” • Standard3pointlockingsystemapplied • Availablein43uand47uHeights • Adjustabledepthreducers • Adjustablepunchedprofiles • Allmetalcomponentsareepoxypowdercoated • CompliestoDIN41494specifications(sections1-4)aswellasANSI/EIA-310-D1992 • AdleRac®isanSABSISO9001:2008certifiedmanufacturer Platinum Range •This rack features a range of aesthetic enhancements and features including ventilatedfrontandrearpanels •Fullyconfigurabletocustomerrequirements •The system is designed with the unique requirements of every customer in mindandcaneasilybeconfiguredtosuitetheseuniquerequirements.Thisis accomplished by us providing a large range of standard components and accessorieswhichcanbefittedtotherackwithease. Technical Specifications 12 Technical Specifications Rack Height 43U 800 x 1,2 m x 24” Rack Height 47U 800 x 1,2 m x 24” NetWeight 189KG NetWeight 190KG MaximumHeight 2120 mm MaximumHeight 2300 mm MaximumWidth 800 mm MaximumWidth 800 mm MaximumDepth 1200 mm MaximumDepth 1200 mm ShippingWeight 210.9KG ShippingWeight 220.9KG ShippingHeight 2150mm ShippingHeight 2330 mm ShippingWidth 830 mm ShippingWidth 830 mm ShippingDepth 1230 mm ShippingDepth 1230 mm WeightCapacity(staticload) 1363.64KG WeightCapacity(staticload) 1363.64KG WeightCapacity(dynamicload) 1022.73KG WeightCapacity(dynamicload) 1022.73KG MinimumMountingDepth 262.00mm MinimumMountingDepth 262.00mm MaximumMountingDepth 1000 mm MaximumMountingDepth 1000 mm Color BlackorGrey Color BlackorGrey IP Rated Racking Solutions IP Wall Boxes Key Features Sheetsteeldooratfront(180°),withcomforthandleforsemi-cylinder andsecuritylock3524E;sheetsteeldooratrear(130°)withhandle andsecuritylock3524E. Material: Sheetsteel/3CR12StainlessSteel Surface finish: Enclosureframe: Dipcoat-primed Doorsandroof: Dipcoat-primed,powder-coatedin RAL7035 Glandplatesand punchedsectionswith Zinc-plated,passivated mountingflanges: Supply includes: Enclosureframewithdoors,roof plate,multi-pieceglandplate,2 punchedsectionswithmounting flangesintheenclosuredepth. DetaileddrawingavailableontheInternet. IP Wall Box Sizes Item U Size Dimension Y 1 6U 347mm 2 9U 480 mm 3 12U 614 mm 4 15U 748mm 13 IP Rated Racking Solutions IP54 and IP65 Cabinets Key Features Sheetsteeldooratfront(180°),withcomforthandleforsemi-cylinder andsecuritylock3524E;sheetsteeldooratrear(130°)withhandle andsecuritylock3524E. Material: Sheetsteel/3CR12StainlessSteel Surface finish: Enclosureframe: Dipcoat-primed Doorsandroof: Dipcoat-primed,powder-coatedin RAL7035 Glandplatesand punchedsectionswith Zinc-plated,passivated mountingflanges: Supply includes: Enclosureframewithdoors,roof plate,multi-pieceglandplate,2 punchedsectionswithmounting flangesintheenclosuredepth. DetaileddrawingavailableontheInternet. IP65 Cabinet Sizes 14 Item USize DimY DimX 1 25U 1479mm 600/800/1000 2 34U 1880mm 600/800/1000 3 38U 2057mm 600/800/1000 4 43U 2279mm 600/800/1000 5 47U 2457mm 600/800/1000 Co-Location Cabinets The AdleRac® co-location range has been designed to accommodate the requirements of multi user requirements.Available in a range of formats. There areachoiceof4differentconfigurationsavailableinmultiplefootprintsizes.Inthe continuedstruggleforrealestatewithinthedatacentre,theco-locationrangewill providethemaximumutilisationofspace. Co-Location Witharangeofchoicesavailablethereisaco-locationcabinetforanyinstallation. This can be combined with anyAdleRac® cabinet to provide a solution for any co-location environment and provide additional revenue per square metre. The productissuppliedwithsecureinternalcabletrunkingtoprovidetotalsecurityfor eachcompartment.Thistrunkingcanbeaccessedfromthetopandthebottomof eachenclosure.Securityhandlesareusedtoensurecustomerprotection. Typical Applications • ServerFarms • MultipleCo-LocationDataCentres • HostingCentres 15 Co-Location Cabinets Full Rack Features List • MeshfrontdoorswithcombinationlockswithmasterKeyoverride • MeshreardoorswithcombinationlockswithmasterKeyoverride • 19inchmountingangles(2xRear2xfront) • 1,2,4and9optionco-locationcabinets • 2 way cable secure ducting accessible in each location and top and bottom access • HeavyDutyCastorsfittedasstandard • Earthingkitssuppliedtoeachsection • Two compartment or four compartment options available. Fitted with vented doorstothefrontandrearasstandard • Fullyenclosedbayswithfullyventeddividershelves • Enclosedcableductingfittedasstandard • Fullrangeofaccessoriesoptionalandadaptable Benefits and Additional Features • Floorspaceoptimisation • CompatablewithbayingAdleRac®DataandServerCabinets • CompatabilitywiththefullrangeofAdleRac®accessories • Multiple working variants available to assist in providing differing levels of security Typical Applications • ServerFarms • MultipleCo-LocationDataCentres • HostingCentres 16 Co-Location Cabinets 2-Way Split Rack Features List • MeshfrontdoorswithcombinationlockswithmasterKeyoverride • MeshreardoorswithcombinationlockswithmasterKeyoverride • 19inchmountingangles(2xRear2xfront) • 1,2,4and9optionco-locationcabinets • 2 way cable secure ducting accessible in each location and top and bottom access • HeavyDutyCastorsfittedasstandard • Earthingkitssuppliedtoeachsection • Two compartment or four compartment options available. Fitted with vented doorstothefrontandrearasstandard • Fullyenclosedbayswithfullyventeddividershelves • Enclosedcableductingfittedasstandard • Fullrangeofaccessoriesoptionalandadaptable Benefits and Additional Features • Floorspaceoptimisation • CompatablewithbayingAdleRac®DataandServerCabinets • CompatabilitywiththefullrangeofAdleRac®accessories • Multiple working variants available to assist in providing differing levels of security Typical Applications • ServerFarms • MultipleCo-LocationDataCentres • HostingCentres 17 Co-Location Cabinets 4-Way Split Rack Features List • MeshfrontdoorswithcombinationlockswithmasterKeyoverride • MeshreardoorswithcombinationlockswithmasterKeyoverride • 19inchmountingangles(2xRear2xfront) • 1,2,4and9optionco-locationcabinets • 2 way cable secure ducting accessible in each location and top and bottom access • HeavyDutyCastorsfittedasstandard • Earthingkitssuppliedtoeachsection • Two compartment or four compartment options available. Fitted with vented doorstothefrontandrearasstandard • Fullyenclosedbayswithfullyventeddividershelves • Enclosedcableductingfittedasstandard • Fullrangeofaccessoriesoptionalandadaptable Benefits and Additional Features • Floorspaceoptimisation • CompatablewithbayingAdleRac®DataandServerCabinets • CompatabilitywiththefullrangeofAdleRac®accessories • Multiple working variants available to assist in providing differing levels of security Typical Applications • ServerFarms • MultipleCo-LocationDataCentres • HostingCentres 18 9-Way Split Rack Features List • MeshfrontdoorswithcombinationlockswithmasterKeyoverride • MeshreardoorswithcombinationlockswithmasterKeyoverride • 19inchmountingangles(2xRear2xfront) • 1,2,4and9optionco-locationcabinets • 2 way cable secure ducting accessible in each location and top and bottom access • HeavyDutyCastorsfittedasstandard • Earthingkitssuppliedtoeachsection • Two compartment or four compartment options available. Fitted with vented doorstothefrontandrearasstandard • Fullyenclosedbayswithfullyventeddividershelves • Enclosedcableductingfittedasstandard • Fullrangeofaccessoriesoptionalandadaptable Benefits and Additional Features • Floorspaceoptimisation • CompatablewithbayingAdleRac®DataandServerCabinets • CompatabilitywiththefullrangeofAdleRac®accessories • Multiple working variants available to assist in providing differing levels of security Typical Applications • ServerFarms • MultipleCo-LocationDataCentres • HostingCentres 19 ETSI Cabinets TheETSIstandardisthecurrentformatforenclosuresusedintheTelecommunicationsindustryandhasbeenestablishedbytheEuropeanTelecommunications StandardsInstitute-henceETSI.The19”standardisageneralpurposeformat usableinawidevarietyofapplicationsincludingTelecommunications. Whereas ETSI enclosures are meant specifically for telecommunications applicationsandtohousetelecomequipmentbuilttotheETSIformat.However,19” RackmountableequipmentcanalsobehousedinETSIcabinetsthroughtheuse of19”adapterswhichconvertfromETSIdimensionsto19”mountingdimensions. Buttheoppositeisnotpossible-i.e.ETSIequipmentin19”Racks. ETSIcabinetsaregenerallyof2200mmheightoverall,andeither300mmor600mm depth,overall.Cableentryprovisionisprovidedattopandbottom.Rearpanelsand frontdoorsareoptional.Twoversionsareonofferthe300mmD“SHALLOW”ETSI Rackwhichhasfixedsidepanels,andthe600mmD“DEEP”ETSIRackwhichhas removablesidepanels. Benefits and Features • Toppanelofrectangularboxtypeshape • TopandbottomcableentryprovisionwithglandplatesM10liftingboltprovision • PairofETSIpanelmounts(2.0mmsteel)withzincplatingandyellowpassivation asastandardsupply • 4pairsofpanelmountsupports • Basic frame of welded construction made from steel sheet 1.6mm thick, and powder-coated • Sidepanelsandbottompanelshavingvents,madefrom1.6mmsteelsheet • Steel&glassdoorin1.6mmsteel;rearpanelin1,6mmsteel 20 Custom Racking Solutions Adlerac® Slack Rack Theidealsolutionformassivecabledensitiesexperiencedtodayby sprawlingenterprises.Thisslackcabinetdoesexactlywhatitsname implies-takealltheexcesscableandstoresitawayneatly.Itfits flushagainstAdleRac®’sGoldRackandthusblendsinharmoniously withitsenvironment. Available in heights of 38’U’, 43’U’ and 47’U’ 300mm wide with depthsof600mmand900mm. Adlerac® Comms Rack This is the ideal solution for all telecommunications rooms. This AdleRac® cabinet is fitted to a telecoms wall and houses the interconnectingblocksforalltelecommunicationslinksfromoutside thebuilding. Various telecoms panel options are available.Available in heights of38’U’,43’U’and47’U’300mmdeepand600mmor900mmwide optionsavailable. Adlerac® Split Rack ThisingeniousdesignfromAdleRac®istheidealsolutionforserver rooms where various people need to operate on the cabinet.The cabinetissplitandhasthreelockablecompartments.Thebottomis wheretheserverishoused,inthemiddleisyourlockablekeyboard withmonitorandswitchingequipment.Thisdesignenablesaccess to the right people to the right equipment. Thereby securing that unnecessarydowntimeisavoided. Adlerac® Ventilated Rack ThisAdleRac®wasdesignedforequipmentthatrequireshighlevels ofcoolinginenvironmentsthatareexposedtoinsects.Allcooling panelsareventilatedandaccessintotherackissealed. 21 Rack Accessories Accessories • • • • • • • • • • • • • • • Front mounting equipment trays Flat mounting equipment shelves Sliding trays Mini keyboard sliding trays Power distribution duct Cable trays Additional punched profiles Additional depth reducers Cooling fans Patching panels (various types) Blank panels Cable management panels Gland plates Mounting hardware Mobile bases (castors) IEC Powerduct with display Ventilation Fan Panel Please call for complete range of accessories Fan Trays Recess panel with DIN rail Cable management trays Sliding keyboard trays Drawer Unit Cable management panels - Telkom Flat mounting equipment shelves 22 THE ULTIMATE PDU 9072/14370 • SABS approved Power Distribution Units • Robust aesthetically pleasing design • Conforms with both national and international sockets • 16A rated at 250Vac • Fitted with 1x additional IEC 60320 C13 10Amp socket • Easy installation into rear of rack via pre-punched mounting holes COMMITTED TO SERVICE EXCELLENCE 23 APS Basic PDW Range 9072/14370 C13 C19 SouthAfricansocket Schukosocket PowerStripC13 Britishsocket OurAPSBasicRangePDU’shavetheadvantageofbeingbefittedwitha32AIEC309(Caravan/Commando)styleplug. PDU’Switha32AmpIEC309plugandtheSouthAfricanstyle16Asocket,ortheGermanstyle15ASchukosocket,andthe 13ABritishsocketshavethedisadvantagethatyoucannotdrawthefull32Afromthesupply.Inmostapplicationsthisisnota problem,astheequipmentconnectedtothePDUdoesnotdrawmorethanthecurrentofthecircuitbreaker,i.e.wherethere isa32Asocketprovided,thePDUneedsaplug.Theconnectedequipmentthendoesnotneed32Aintotal. 16A Rated PDU Features • 16Aratedat250Vac • Protectedwith16Acircuitbreaker • Fittedwith1xadditionalIEC60320C1310Asocketfor theconnectionoffantraysandother19”Rackequipment • 5metre3core1.5mmSQincominglead • Availableintwolengthswitheither5or10socketsrated 16A • EasyinstallationintorearofRackviapre-punched mountingholes APS Part Number Description APS Part Number Description 1RA-PDW05/SABS APS5wayPDUSABSGrey 1RA-PDW10B/SABS APS10wayPDUSABSBlack 1RA-PDW05B/SABS APS5wayPDUSABSBlack 1RA-PDW10G/SABS APS10wayPDUSABSGrey 1RA-PDW05B/16A APS5wayPDU+3092P+E16APlugBlack 1RA-PDW10B/16A APS10wayPDU+3092P+E16APlugBlack 1RA-PDW05G/16A APS5wayPDU+3092P+E16APlugGrey 1RA-PDW10G/16A APS10wayPDU+3092P+E16APlugGrey 1RA-PDW05B15/32A APS5wayPDU+3092P+E32APlugGrey 1RA-PDW10B15/32 APS10wayPDU+3092P+E32APlugBlack 1RA-PDW05G15/32A APS5wayPDU+3092P+E32APlugGrey 1RA-PDW10G15/32 APS10wayPDU+3092P+E32APlugGrey 32A Rated PDU Whenafull32Ampcurrentdrawisrequired,APShasdevelopedasecondoptionthatcanprotectuptoamaximumof10 16Ampsockets,byfittinga32Ampcircuitbreaker.Weofferacost-effectivesolutiontothisapplication. Features • 32Aratedat250Vac • Protectedwith32Acircuitbreaker • Fittedwith1xadditionalIEC60320C1310Asocketfor theconnectionoffantraysandother19”Rackequipment • 5metre3core2.5mmSQincomingleadfittedwith IEC30932Aplug(Caravan/Commandotype) • Availableintwolengthswitheither5or10socketsrated 16A • EasyinstallationintorearofRackviapre-punched mountingholes APS Part Number Description APS Part Number Description 1RA-PDW0530B/32 APS5wayPDU+32ACB+32APlugBlack 1RA-PDW1030B/32 APS10wayPDU+32ACB+32APlugBlack 1RA-PDW0530G/32 APS5wayPDU+32ACB+32APlugGrey 24 1RA-PDW1030G/32 APS10wayPDU+32ACB+32APlugGrey APS IEC PDU Range TherecentlyintroducedAPSIECPDUrangefeaturesthecompleterangeofIEC60320sockets.TheprimaryinletsareC13 orC19sockets.TheincomingplugsareavailablefromthestandardSouthAfrican3pin16AtotheIEC30916Aand32A.On requesttheC20/C19inlineplugandsocketcanbeaccommodatedonthestandard5meterincominglead. 15A Rated PDU Features • 15Aratedat250Vac • Protectedwith16Acircuitbreaker • 12PortC1319”x1Uhorizontalorverticallyasper bracketsetsupplied • 5metre3core2.5mmSQincomingleadfittedwith IEC30916Aplug • Finishedingreyorblack APS Part Number Description APS Part Number Description 1RA-IEC12WC13/1 APSIEC12wayC13PDU+5MSAP/TOPGrey 1RA-IEC12WC13/7 APSIEC12wayC13PDU309-32A2P+EGrey 1RA-IEC12WC13/B APSIEC12wayC13PDU+5MSAP/TOPBlack 1RA-IEC12WC13B7 APSIEC12wayC13PDU309-32A2P+EBlack APS Part Number Description APS Part Number 1RA-IEC12WC13/3 APSIEC12wayC13PDU309-16A2P+EGrey 1RA-IEC12WC13D1 APSIEC12wayC13PDU+DISPGrey 1RA-IEC12WC13B3 APSIEC12wayC13PDU309-16A2P+EBlack 1RA-IEC12WC13D2 APSIEC12wayC13PDU+DISPBlack Description 25 The IP-EV Bio Unit Enclosure ThecostofData,ordinarilyoutweighsthecostofanyotherasseta companycanhaveintoday’sworld.Thus,itisimperativethatitis amplyprotectedagainsttheft,fire,wateretc. Adlerac’ design experts have engineered a first-class all-rounder solutionwhichfeaturesthe ..best of both worlds… Incorporating the EV or Environmental Enclosure’s, versatile interiorcontainmentwithhighqualityIngressProtected(orNEMA) featuresbuilttotherequiredstandardofprotectionneededagainst rust&corrosion,moisture,dustand/orimpact,andagainstintrusion fromforeignbodies. EV Enclosures The “EV Enclosure” stands for Environmental Enclosure, and is essentially an enclosure which secures, manages and controls its own internal environment. .It is an access controlled server rack which is self-contained with a secure environment hosting all of the features which you would typically find in a well thought out “computerroom”. The ‘Environment’ of the enclosure’s interior is monitored, using state-of-the-art technology and gear. The Enclosure is specifically designed to accommodate internally mounted air-conditioning, critical for the management and control of the enclosure’s Interior environment. TheEVenclosureismodularindesign,thusallowingforexpansion tomeettheneedsoftheamountofhardgearandequipmentneeding storageandprotection.Thisallowsasingle,double,tripleorquad setofEVEnclosuregrouping,thusprovingacost-effectivesolution designedtomeetdifferentrequirements. TheEVEnclosureisahigh-securityenclosurepreventingunwanted intrusion.The level of security can be selected, using bio-metrics, including Retina Pattern Biometric Systems, Voice Patterns BiometricsSystems,orFingerprintsBiometricsystems. The EV Enclosure can be provided with an early-warning system, byinstallingaremotemonitoringunit,whichmeasurestemperature, humidity,dewpoint,airflow,andaudiblesounds(e.g.alarms).This active monitoring, early detection and instant alerting system can graphabnormalities,recordvideo,takepictures,andrecordsound clips as soon as intrusion is detected. All this information can be accessedremotely,andtheunitsendsoutalertsandwarningsvia, SMS,E-mail,SNMP,FTP,HTTPandWebServices.Warningsare sentoutassoonasoneofthewarningsystemsaretriggered. TheEVEnclosureisdesignedwithinsulatedandremovablepanels, andcabledistributionsystemsallowingforeasymanagementand control of cabling and access. All parts are either epoxy powder coated, or plated – to exude a superior finish.Your company logo canbebrandedonthefrontoftheplexi-glassdoor. Contactoneofourenclosurespecialists,foranexcitingpreviewof an exclusive, yet cost-effective all-in-one solution for your server enclosureneeds. 26 The IP-EV Bio Unit Enclosure Specifications Sheetsteeldooratfront(180°),withcomforthandleforsemi-cylinder andsecuritylock3524E;sheetsteeldooratrear(130°)withhandle andsecuritylock3524E. Construction and manufacture • The construction of the Cabinet’ Structure is Rigid – it is full throughTigwelded,andmanufacturedin2.0mmMildSteeland hasanEpoxyPowderCoatedfinish. • Doorsaremanufacturedin1.6mmMildSteelandhaveanEpoxy PowderCoatedfinish. • Doorshavea3-PointSwing-handlekey-lockSystem. • HingesareSolid-Brassforhighersecurity. • TheconstructionoftheCabinetisRigid Compliance TheI.P–EVBioUnitcompliestotheElectronicIndustriesAlliance (EIA)’s - 310D Standard for 19” Racking. It defines a 1.75-inch (44.45mm=1U)‘rackspace’height,anda19-inch(482.6mm)width tomakeequipmentinterchangeablewithincommonhousings. It also complies to the German Institute of Standardisation or DIN (DeutschesInstitutfurNormunge.V.)’s41494SC48DStandardfor 19”Racking. Different Solutions Available Accordingtothelevelofsecurityand/orprotection,youcanmake yourselectionfromthefollowingoptions: Lighting Solution: • HighQualityOsramLEDLightingiswiredintotheUnit,providing sufficientlight,operatesontriggersseteitherbydoorcontactors orelectricallocks. High Security Solution: • A Sagem fingerprint scanning Biometrics unit, with keypad is installed(Thisbiometricsunitisproventobeoneoftheleading brands in the world, and is used for government security worldwide.) • Ahigh-securityElectronic3-PointisinstalledwiththeBiometrics unit,inadditiontothestandardlockingsystem. • Aback-upbatteryisinstalledfortheElectronicLockingSystem. Remote Access Early Warning & Monitoring Solution: • ANetbotzUnitisInstalled,whichisinvaluabletoprotectingData. Fire Extinguishing Solution: • APyrora2UFireDetecting&ExtinguishingUnitisInstalled. 27 EV-Rack® Anatomy Condensation Tray Air-Conditioner Flashing TopMount Air-Conditioner FrontDoorwith ToughenedGlass AccessControl Panel Removable SidePanelwith 100%Insulation RigidMetal Frame Sandblasted Company Logo SecureMag-Lock DepthReducer SlackRack 2xCableTrays PerRack EV-Rack 1 EV-Rack 2 28 Plinth EV-Rack® Configuration The drawings show standard configurationsoftheEV-Racks®. SingleEVRack EV-Racks® Racks are logically configured as illustrated for the purposeofeffectivelyutilizingthe fullpotentialofthefeatures. Forexampleasingleair-conditioning unit can be used to effectively control the temperature in a single, double, triple or quad EVRacks®, so depending on the amountofequipmentusedbythe customer,acost-effectivesolution can be designed to meet all the requirements. DoubleEVRack Features and options provided byaccesscontrolandmonitoring systems can be exploited to a greaterdegreethusjustifyingthe inclusionoftheseintothesystem Whatever the configuration of the EV-Racks®, it will always be a continuous closet. This will facilitate seamless patching and cross connecting of equipment andpatchpanelswithouthavingto TripleEVRack provide for additional reticulation betweenracks. The drawings show the recommended configurations but the EV-Racks® system is not limited to these. It is possible to assemble the system into a five way andevenasixwayifyourI.Tand Business Infrastructure requires it.Futureproofingyourrackingrequirementisastandardbasedon QuadEVRack CapacityManagement. Our specialists can consult with you to determine the exact requirements and design a suitable solution for your specific application 29 EV-Rack® Access Control – Suprema IP based Fingerprint Access Control BioEntry Plus is an IP based fingerprint access control device featuring easy installation and user friendly operations. Integrated with both fingerprint and proximitycard,BioEntryPluscoversafullrangeofaccesscontrolapplicationsfrom asimplestandalonedoorcontroltocomplexnetworkedaccesscontrolsystems. WeprimarilyusethisunitonSingleEVRackapplications. Specifications CPU 400MHzDSP Memory 4MBflash+8MBRAM Fingerprintsensor 500dpiopticalsensor Identificationspeed 2000matchin1second Fingerprintcapacity 5000fingerprinttemplates Logcapacity 50000events RFcard 125KHzproximity(EM) Operationmodes Fingerprint,RFcard,RFcard+fingerprint Networkinterface TCP/IP,RS485 Wiegandoutput Configurableupto64bits TTLI/O 2inputsforexitswitchanddoorsensor Internalrelay Deadbolt,EMlock,doorstrike,automaticdoor Soundandinterface Multi-colorLEDandmulti-tonebuzzer Operatingvoltage 12VDC Size 50x160x37mm(WHD) Incorporating Suprema’s industry-leading fingerprint recognition algorithm, BIOSTATIONoffersaperfectsolutionforaccesscontrol. WithacolorLCDandhighqualitysound,BIOSTATIONprovidesadifferentlevelof userinteractionusingmultimediainformation.Versatileinterfaceoptionsincluding wireless LAN and USB memory slot enable easy network integration and data transferwithoutanywiring. WeprimarilyusedthisonDouble,TripleandQuadEVRackapplications. Specifications CPU DualCPU(32bitRISC+400MHzDSP) Memory 72MBflash+34MBRAM Display 2.5”QVGA16MColorLCD Identificationspeed 3,000matchin1second Fingerprintcapacity 50,000fingerprinttemplates Logcapacity 500,000events RFCard 125kHzEMCard,HIDProx.(Optional) Networkinterface WirelessLAN(optional),TCP/IP,RS485 PCinterface USB,RS232 USBmemoryslot USBHost Outputrelay Deadbolt,EMlock,doorstrike,automaticdoor WiegandI/O,4TTLI/O Microphoneandspeakerfordoorphone Navigationkeyformenumovement 4Functionkeysforuser-definedfunctions 30 Operationmodes Fingerprint,PIN,PIN+Fingerprint,Card,Card+Fingerprint, Card+PIN(RFmodel) Size 135x128x50mm(WxHxD) EV-Rack® Thermal Management – Panasonic PerformancecommunicationsandIThardwarehavethecapacitytogenerateheat. ThetemperatureinRackhousingthisequipmentcanrisequiterapidly.Inmany instanceregulationoftemperatureinachievedbyexpellinghotairfromtherack whilstcolderairfromacontrolledcomputerroomwillbedrawnintotherack.Since the EV-Rack®isastand-alonehousingforhighperformancecommunicationsand IThardwareitcannotrelyonthesurroundingenvironmentforregulatingitsinternal temperature.Thus the use of an air-conditioning unit is an essential part of the concept. Ofthe many options available we recommend one of the following solutions for EV-Rack®ThermalManagement: • Topmountingair-conditioner • Sideattachingair-conditioner DependingontheconfigurationofyourEV-Rack®ourspecialistscanadviseonthe mostsuitablesolution. Top Mounting Air-conditioning unit Common Features • Reciprocatinghermeticcompressorwiththermal-amperometricprotection • EcologicR134arefrigerant,CFCfree • Condensingandevaporatingheatexchangecoilsincopperpipewith aluminiumfins • Internalandexternalfansonballbearingswithinternalthermalprotection • Mechanicalcontrolthermostatsetat35°C,deadband4°C • SteelsheetfrontcoverpowderpaintedRAL7032orangepeel(gray) • Nofilter • Allmodelshavetheheatexchangersurfacesspecificallydesignedtoprevent cloggingbyparticlesandfibresintheambientair.Therefore,theyremainvery efficientevenintheworstambientconditionsandfiltersareeliminated. • Condensatedissipator • Unitsequippedwithacondensatedissipator;adevicethatsolvestheproblems ofcondensatemanagementandevacuation. • Environmentsafety • Inallstages,fromthedrawingboardtothecreationofourproducts,EEC safetyregulationsandenvironmentalresourcesarerespected,usingecological gasesandrecyclablematerials • Doublecondensateprotectionsystem • EBB • Thisisadevicewhichallowselectronicmanagementofthemainconditioner functions. Hide-Away Panasonic Top Mount Air-conditioner This is an 18,000 BTU air-conditioning unit particularly suitable for installations requiringhighvolumesofcooledairasanalternativetooneoftheaboveoptions. Theunitis27cmhighandlightweightmakingitideaforthisapplication,itisalso easilymaintainedwithflexibleaccesstofilters. * Fullspecificationavailableonrequest;pleaseconsultoneofourspecialistsfor moreinformation. 31 EV-Rack® Fire Suppression – PanelSafe® Data processing, telecommunications, ISPs and production plants are today increasinglydependentonthepermanentavailabilityoftheirelectronicequipment. Failure of such equipment leads to severe disruption and consequent loss of revenue.Effectivefireprotectioniscrucialbecauseitisoftennotonlythefirebut thefumesthatdamagethecomponents. Features • Space saving – 19”-unitwith4Uinheight • Rapid detection – Smokedetectorslocatedwithinthe19”cabinet • Minimising damage – viaautomaticshutdowncontact • Rapid extinguishment – duetothedirectdischargeoftheFM-200orNovec1230 suppressantwithinthecabinet • Simple installation and commissioning – withpre-assembledcomponents • Easy maintenance – duetomodularconcept • Quick and safe recognition of events – reportedviadetailedmultifunctionaldisplay • Safe protection of large cabinets – Evencabinetsupto6m3canbeprotectedbyusingslave units Specifications 32 Inputsupply 230VAC±15% OutputVoltage 24VDC,1A,forexternalcontrolpurposes,sounderandextinguishingfan Battery 2Ah(sufficientfor4hours) Smokedetectors 2opticalscatteredlightdetectorsusedintwo-detectorcoincidencedetection Supervisedin-andoutputs formainssupply,smokedetectors1&2,manualrelease,extinguishingfan,alarmhorn Voltage-freerelayoutputs forpre-alarm,mainalarm,commonfaultandshutdowncontact(contactload30VA) Suppressant FM-200,C3F7H/N2(25bar)orNovec1230,C6F12O/N2(25bar) Suppressantcylinder 1litre,foramaximumof1.2m3protectedvolume,approvedaccordingtoRL97/23/EGandRL 1999/36/EG Operatingtemperaturerange 0°Cupto40°C Weight Approximately14kg Indications Mains supply, CPU, common fault, smoke detectors 1 & 2, manual release, extinguishant container (pressure switch), extinguishing fan, sounder, external control, discharge actuator, pre-alarm,mainalarm,discharge(suppressantreleased) Servicebuttonsresp.keyswitch Uniton/off,extinguishmenton/off,reset Dimensions Width 19” Height 4Uinheight Mountingdepth 403.25mm EV-Rack® Monitoring – Geist IT equipment continues to push upward in both power consumption and cooling demand.FormostITManagers,understandingwhereandwhenthesepowerand environmental conditions impact data center dynamics and reacting to adverse conditions can be a daunting task. Geist’s RacSense® line of products brings visibilitytothefingertipsofdatacentermanagers,allowingfortheultimateinremote monitoring of environmental conditions. Whether your data center is across the building,acrossthecountry,oraroundtheworld,RacSense®keepsyouincontrol. Conveniently Accessed Diagnostic Data ♦User-definedgraphingvariables ♦Logdataavailableforexportto XML ♦Logdataavailablereal-timevia SNMPorXML ♦PDAandWAPscreenformats ♦User-definedalarmthresholds ♦Simultaneousaccessbymultiple users ♦Diagnosticeventlogfor situationalanalysis Timely Monitoring and Alarm Notification ♦SNMPtrapsforalarmsetand alarmclear ♦E-mailnotification ♦Audiblealarm(GRSE2X16only) ♦Combinationsoftheabove Protected Access ♦Multi-levelpasswordprotection ♦Viewonlyprivileges ♦HTTPS(SSL&TLS)forsecure link Friendly Names ♦Units&sensorsmaybegiven logicalnames Self-Contained Operation ♦Noclientsoftwarerequired ♦Viewableviawebbrowser ♦Interfaceswithremotedisplay andwebcamera Simple Installation RSE-B ♦StaticIP-viewableviaweb browser ♦DHCPIPassignments(optional) ♦Automatictimesetviainternet timeservers RSE-2X16 Ease of Expansion ♦Externalsensorsmaybeadded atanytime RSMINI163 ♦Externalsensorsare automaticallydiscovered 33 ATEN Data Center KVM Solution Guide Limitless control over the Data Center ATEN Solutions are ideal when you or your client... • IsaDataCenterManager,ITInfrastructureManager,NetworkManager,Directorof Operationsorisaninfrastructuredecisionmakeraboutnetworkinghardware,power orserverracks • Isplanningadatacenterupdateorbuildinganewdatacenter • Has purchased multiple servers for the same location or has remote or branch offices • UsesmultiplePCsonthesamedesk • Needsremote,BIOSlevelaccessthatKVMandserialoverIPsolutionsprovideto managecriticalequipment • Issettingupaco-locationordisasterrecoverysite • HaslimitedITStaff • Hasalargewebserverenvironment Q:Whatdoyoudowhenrackspaceisatapremiumand youneedaccesstomultipleserversremotely? A: KL1516, CAT5 Dual Rail 16-Port LCD KVM Switch •IntegratedKVMconsolewith17”or 19”LCDmonitorinaDualRailhousing •RJ-45connectorsandCat5cable –extendsthedistancebetween computersandswitchupto40m 130ft.forresolutionsof1280x1024 @60Hz Q:Areyoulookingforaqualityenterprise-levelCAT5KVM solutionatanSMBpricepoint? A: KH1508/KH1516, 8/16-Port CAT5 KVM Switch •Asingleconsolecontrolsupto8or 16directlyconnectedservers • Daisy chain up to 31 additional unitsandcontrolupto256or512 computersfromasingleconsole •Nosoftwarerequired Q:Whatdoyoudowhenserversgodownatdatacenteror remotelocations? A: PN9108, 8-port Power Over the Net •Remotepoweron/off/rebootcontrol foreightoutletsviaTCP/IPanda builtin10/100Ethernetports •Daisychainupto15additional stationstocontrolupto128outlets Q:Doyoucurrentlyhaveadatacenterbutnoremote access? A: CN8000, Over the Net IP KVM Access Unit •Allowsaccessandcontrolof computersremotely •Supportsupto64useraccounts •VirtualMedia •CompatiblewithallATENKVMs, andmostcompetitors’KVMs 34 Q:Aretheresystemadministratorswhotestapplications beforeactualinstallationonthetargetserver? A: CS62DU, 2-Port DVI USB KVM •OneDVIvideoconsolecontrolstwo USBcomputers •FullyDVI-Digitalcompliantwith resolutionsupto1920x1200@60Hz; DDC2B •Compactdesign,builtinall-in-one cables ATEN Data Center KVM Solution Guide Q:Doyouhavenetworkadministratorsoutsideofthedata centerthatneedaccessatalltimes? A: CE800, USB Console Extender •ConnecttheLocalandRemoteUnits upto820ft. •Built-inUSBportonbothunitssupports externalUSBflashdrivesforeasyfile sharing •Pushbuttonlocksoutthenon-active console Q: Howcanyou,astheITDirectorornetworkadministrator, managealloftheATENIPproductsconcurrently? A: CC2000, Control Center Over the NET™ •CC2000Managementsoftwareoffersa convenienteconomicalCentralized accessandmanagementofyourIT deviceslocatedinRemoteDataCenters andbranchofficesanywhereintheworld Q: Doyouwanttohavemorethantwoadministrators simultaneouslymanageyourmulti-platformserversfrom onelocation? A: KM0932, 9-user, 32-Port CAT5 Matrix KVM •Nineconsolesindependentlyand simultaneouslycontrolupto32 computersdirectly •Multi-platformsupportforPC,Mac andSUN •Consoleconversioncancontrol anytypeofcomputercombinations (PS/2&USB) Q: Doyouhavemultipleserialdeviceslikerouters,firewalls, UNIXservers,andotherserially-controlleddevicesyou wouldliketomanage? A: SN0116, 16-Port Serial Over the Net KVM Switch •Remoteserialaccessoverthe internetforupto16serversor otherserialITdevices •Eachportcanbeaccessed individuallyby16users •Multi-levelsecureuserlogin;user authentication;port-specificaccess rights Q:Doyouwanttomanageyourserversbothlocallyand remotely? A: KN2116, 3-user, 16-Port KVM Over the Net •3simultaneousloginsfromany workstationonyourLANorWAN, orfromtheInternet.. •Canbecascadedtoamaximum of128compatibleKVMsallowing controlforupto1024computers. •Messageboardfeature 35 KVM Solutions – ATEN CS1794 2/4-Port USB 2.0 HDMI KVMP™ Switch Combining a 4-port switch with a 2-port USB 2.0 hub, the CS1794providesseamlessHDMIsignalswitchingbetween 4PCsorotherHDMI-enableddevices,andallowsusersto share USB peripherals from a single console.The CS1794 provides enhanced independent switching via front panel pushbuttons and keyboard hotkeys, and features Video DynaSync™ technology to ensure that HDMI display resolutionisalwaysoptimized.Withintegrateddigitalaudio, the CS1794 also allows users to experience high-definition sound,suchasDolbyTrueHDandDTSHDMasterAudio. Features: •OneUSBconsolecontrolstwo(CS1792)orfour(CS1794) HDMI-interfacecomputersandtwoadditionalUSB devices Specifications ComputerConnections 4 FrontPanelPushbuttons; PortSelection Hotkeys 1xUSBTypeAFemale Keyboard (Black;rearpanel) 1xHDMITypeAFemale Video (Black) Console 1xUSBTypeAFemale Mouse Ports (Black;rearpanel) 2xMiniStereoJackFemale Speaker (Green;1xfront,1xrear) 2xMiniStereoJackFemale Mic. (Pink;1xfront,1xrear) Connectors Keyboard/ 4xUSBTypeBFemale Mouse (White) 4xHDMITypeAFemale Video (Black) KVM Ports 4xMiniStereoJackFemale Speaker (Green) 4xMiniStereoJackFemale Mic. (Pink) 1x4-conductor3.5mmJack F/WUpgrade (Black) Emulation •DolbyTrueHDandDTSHDMasterAudiosupport •Superiorvideoquality–supports480i,480p,720p,1080i, and1080p(1920x1200) •Powerondetection:whenoneofcomputersisswitched offtheKVMwillswitchautomaticallytothenextpower-on computeraccordingly •Supportswidescreenresolutions •Multiplatformsupport–Windows2000/XP/Vista,Linux, andMac •Consolemouseportemulation/bypassfeaturesupports most mousedriverandmultifunctionmice •VideoDynaSyncTM–storestheconsolemonitorsEDID (ExtendedDisplayIdentificationData)tooptimizedisplay resolution •Mackeyboardsupportandemulation* Selected Audio 2xUSBTypeAFemale (White;1xfrontpanel;1x rearpanel) 5xPushbutton 5(Green) KVM 5(Orange) USB Keyboard/Mouse 5(Green) USB 1080p(HDTV)/1920x 1200(DVI) 1-99secs.(Default:5secs) DC5.3V,4.8W 0-50ºC -20-60ºC 0-80%RH,Non-condensing Metal,Plastic 0.53kg Video ScanInterval PowerConsumption OperatingTemp. Environment StorageTemp. Humidity Housing Physical Weight Properties Dimensions (LxWxH) 36 •HDMIdigitalandanalogmonitorsupport–fullycompliant withHDMI1.3a;alsoHDCPcomplaint •Completekeyboardemulationforerror-freebooting USB2.0Hub LEDs •IndependentswitchingofKVM,USBperipheral,andaudio focusviafrontpanelpushbuttonsandhotkeys 1xDCJack Power Switches • 2-portUSB2.0hubbuiltin;fullycompliantwiththeUSB 2.0specification 26.50x7.30x4.50cm •AutoScanModeformonitoringallcomputersandHDMI devices • FirmwareUpgradable KVM Solutions – ATEN CL1008 8-Port Slideaway™ LCD KVM Switch The CL1008 / CL1016 LCD KVM Switch series are control units that allow access to multiple computers from a single keyboard, video, and mouse (KVM), console. A single CL1008orCL1016cancontrolupto8or16computers.As manyas15additionalKVMswitchescanbedaisy-chainedto theCL1008/CL1016,sothatupto256computerscanallbe controlledfromasingleKVMconsole. The CL1008 / CL1016 offers a space-saving, streamlined approachtoKVMswitchtechnologybyintegratingakeyboard, 17” LCD monitor, and touchpad in a 1U rack-mountable slidinghousing. Features: • IntegratedKVMconsolewithanLCDmonitorina Slideaway™housing •LCDmodulerotatesupto115degreesforamore comfortableviewingangle •Daisy-chainupto15additionalunits–controlupto256 computers •Nosoftwarerequired–convenientcomputerselection viahotkeysandmousedrivenintuitiveonscreendisplay (OSD)menus •AutoScanfeatureformonitoringuser-selectedcomputers •BroadcastMode–operationssimultaneouslyperformed onallselectedcomputers,softwareinstallationand upgrading,systemwideshutdown,etc. Specifications Ports 8 Expansion 128(viaDaisychain) Computer PlatformSupport Connector SPHD-15 Platform PS/2 PC • Mac/Sun • LCD 17” PortSelection OSD,Hotkey, Pushbutton Emulation PS/2 •Hotpluggable–addorremovecomputerswithouthaving topowerdowntheswitch Video 1280x1024 ScanInterval(Sec.) 1-255 •Twolevelpasswordsecurity–onlyauthorizedusers viewandcontrolthecomputers;uptofourusersplusan administratorwithseparateprofilesforeach Power Consumption •Superiorvideoquality–upto1280x1024@75Hz SupportsDDC,DDC2,DDC2B Environment •DDCemulationoftheLCDmonitor–VGAsettingsof everyconnectedcomputerareautomaticallyadjustedfor optimaloutputtotheLCDmonitor •Upgradablefirmware •KeyboardLanguagesupport:English(US);English(UK); German;German(Swiss);French;Spanish;Traditional Chinese;Japanese;Korean;Swedish;Italian;Russian; Hungarian 17”LCD 120V,30W/230V,37W OperatingTemp. StorageTemp. Humidity Housing Physical Properties Weight 17”LCD 13.10kg Dimensions (DxWxH) 63.40x48.00x4.40cm 62.60x48.00x4.20cm Diagram •Improveddesign–optionalsinglepersoninstallationkit 37 KVM Solutions – ATEN KN4116 KVM Over the NET™ Features: Specifications Direct Computer Connections Max Local Console Connections Remote PortSelection Connectors Keyboard Console Video Ports Mouse KVMPorts Power LAN Modem USB 16 256*(viaCascade) 1 4 OSD,Hotkey,Pushbutton 1xUSB(F) 1xHDB-15(F) 1xPS/2/1xUSB(F) 16xRJ-45(F) 1x3-prongACSocket 2xRJ-45(F) 1xRJ-45(F) 3xUSB(F) PON 1xRJ-45(F) Switches LEDs Emulation Keyboard/Mouse VideoResolution ScanInterval I/PRating PowerConsumption OperatingTemp. Environment StorageTemp. Humidty Housing Physical Weight Properties Dimensions Diagram 38 Power,PortSelection,Reset OnLine,Selected,Power, Link,10/100/1000Mbps PS/2,USB(PC,Mac,Sun); Serial 1600x1200;DDC2B 1-255Seconds 100-240VAC;50-60Hz;1A 110V/39.60W 230V/40.00W 0-50°C -20-60°C 0-80%RH,Non-condensing Metal 5.52kg 43.36x41.35x4.40cm (19”/1U) •Supportsupto5bussessions-1localand2(KN2132) or4(KN4116/KN4132)remoteadministratorscan simultaneouslyaccessseparateports •16or32portoverIPaccess–monitorandcontrolupto 16or32computers–upto512computersinatwo-level cascade** •Two10/100/1000MbpsNICsforredundantLANortwoIP operation(New) •TwoIPdesignsupports2(KN2132)or4(KN4116/ KN4132)remotesessions(New) •Full-screengraphicalOSDforthelocalconsole-local consoleportswitchingaccomplishedsimplybyclicking withthemouse(New) •Full-screenorsizableandscalableremotedesktop window–infull-screenmodetheremotedesktopdisplay scalestouser’smonitordisplaysize(New) •Remoteauthenticationsupport:RADIUS,LDAP,LDAPS, andActiveDirectory(New) •MagicControlPanel(New) •Highvideoresolution:upto1600x1200@60Hz–32 bitforthelocalconsole;upto1600x1200@60Hzfor remotesessions(New) •MouseDynaSyncforUSBmice-localandremotemouse movementarethesame–noneedtoconstantlyresync thetwomovements. •Multi-languageOSDsupport-English,German,Traditional Chinese,SimplifiedChinese,andJapanese(New) •LocalconsolesupportsbothPS/2andUSBkeyboards andmice(comboconsole) •PortscanbeindividuallyconfiguredforExclusive,Occupy, andSharemodes •RJ-45connectorsandCAT5ecableforaneatandtidy, efficientinstallation-upto40mbetweencomputerand switch •Web-basedWindowsandJavaimplementationsallowthe switchtobeaccessedfromaninternetbrowser •Browseraccesscanbedisabled–WindowsandJava GUIAPprogramsprovidedfornon-browserconnectivity– Javaworkswithpracticallyalloperatingsystems •PanelArrayMode–viewupto32portsatthesametime –upto42portsforcascadedinstallations •Software(On-screen)keyboard,AltusenCC(Control Center)support •ExternalmodemsupportforPPPdialin-remoteuserscan dialinandoperateinlowbandwidthmode •Bandwidthcontrol–Videoqualityandvideotolerancecan beadjustedtocompensateforbandwidthvariationsin ordertooptimizedatatransferSpeed •Windows-basedLogServer •Multiplatformsupport-(Win,Linux,Sun)andVT100 basedserialdevicesKVMAdaptersprovidemulti interfaceaccess–PS/2,USB,SUNandRS-232 •Supports10Base-T,100Base-T,1000Base-T,Auto-Sense, TCP/IP,HTTP,DNS,DHCP,PPP,UDP,ARP,Ping •Multi-levelauthentication:superadministrator; administrator;user;viewer–nolimitonthenumberof eachtype •Advancedsecurityfeaturesincludepasswordprotection andadvancedencryptiontechnologies–1024bitRSA;56 bitDES;256bitAES;and128bitSSL •BIOSleveltroubleshooting KVM Solutions – ATEN KL9108 17” LCD Console with Over the NET KVM Switch The KL9108 is an IP-based KVM control unit that allows both local and remote operators to monitor and access multiple computers from multiple consoles. A singleKL9108cancontrolupto8/16computersandcanbeaccessedfromany computer on the Net. The KL9108 features independently retractable 17” LCD monitorandkeyboardwithbuilt-intouchpad.Tomaximizespaceinyourdatacenter the keyboard “hides away” when not in use, while the thin profile LCD monitor providescontinuousmonitoringofcomputers. Features: • IntegratedKVMconsolewith17”LCDmonitorinaDual Railhousing • Spacesavingtechnologywithdualbusfunctionsupport- 1remoteconsole(onebus)andtwolocalconsoles(one bus)controlupto8computers • Dual-bus-onelocalandoneremoteusercan simultaneouslycontrolseparateports • RemotelyaccesscomputersviatheLAN,WAN,orInternet -controlyourinstallationwhenandwhereyouwant • DualRailhousingisslightlylessthan1Uwithtopand bottomclearanceforsmoothoperationin1Uofrackspace • Extraconsoleport-managecomputersintheLCDKVM switchfromanexternalconsole(monitor,PS/2keyboard, andPS/2mouse) • SupportsexternalPS/2mouse • DualRail-LCDmonitorslidesindependentlyofthe keyboard/touchpad • LCDmodulerotatesupto120degreesforamore comfortableviewingangle • Consolelock-enablestheconsoledrawertoremain securelylockedawayinpositionwhennotinuse • SupportsdedicatedOSDandOSDToolbarinvocation keys • Internetbrowseraccess,WindowsClientandJavaClient provided,JavaClientworkswithalloperatingsystems • GraphicalOSDandgraphicaltoolbarsforconvenient, user-friendlyoperation • Upto64useraccounts-upto32concurrentremote logins • PanelArrayMode-viewall8portsatthesametime. • Messageboardfeatureallowsloggedinusersto communicatewitheachotherandallowsaremoteuserto takeexclusivecontroloftheKVMfunctions • Windows-basedLogServer • RemotepowercontrolforattachedPowerOvertheNET™ devices • Threelevelloginsecurity:Administrator,User,andSelect • Advancedsecurityfeaturesincludepasswordprotection andadvancedencryptiontechnologies-1024bitRSA, 256bitAES,56bitDES,and128bitSSL • RADIUSserversupport • PortscanbesettoExclusive,OccupyandShare • NetworkInterfaces:TCP/IP,HTTP,HTTPS,UDP,RADIUS, DHCP,SSL,ARP,DNS,10Base-T/100Base-TX,auto sense,Ping • Flashfirmwareupgradableovernetworkconnection • SuperA-GradeTFTLCDPanel;ZeroDeadPixel Guarantee • Multiplatformsupport:Windows2000/XP/Vista,Linux,Unix andFreeBSD. Specifications Computer Connections Direct Max. Local Console Connections Remote PortSelection Connectors LEDs Emulation Video OSDHotkey,Pushbutton LAN 1xRJ-45FemaleBlack PON PortSelection 1x08-9Male(Black) 1xSemi-recessed Pushbutton 2xPushbutton Power 1xRocker LCDPower 1xPushbutton LCMAdjustment 4xPushbutton Online 8(Green) Selected 8(Orange) Power NumLock 1(Blue) 1(Green) CapsLock 1(Green) ScrollLock Link 10/100MbDS Keyboard/Mouse Housing 1(Green) 1(Green) 1(Orange/Green) PS/2 1280x1024@75Hz· DDC2B 1600x1200@60Hz· DDC2B 1-255Seconds 100-240VAC:50/60Hz: 1A 120V/31W230V/39W 0-40ºC -20ºC 0--80%RH,Noncondensing Metal Weight 17.1kg 17”LCD Remote ScanInterval lIPRating PowerConsumption OperatingTemp. StorageTemp. Environment Humidity Physical Properties 1 1x6-pinMini-DINFemale Keyboard (Purple) External Console Video 1xHDB-15Female(Blue) Port 1x6-DinMini-DINFemale Mouse (Green) 8xSPHO-15Female KVMPort (Yellow) 1x6-DinMini-DINFemale ExternalMouse (Green) Power 1x3-prongACSocket Reset Switches 8 64(viaCascade) 1 Dimensions(LxWxH) 70.5x48.2x4.4cm 39 KVM Solutions – ATEN KM0932 17” LCD Console with Over the NET KVM Switch Features: Hardware • 9consolesindependentlyandsimultaneouslycontrolupto32 directlyconnectedservers • Flexibleexpansion-theinstallationcangrowasyourneeds grow • Audiosupportformultimedia-capabledevices • Redundantpowersupplyfor24x7reliability • Multiplatformsupport:PC,Mac,Sun,andSerialConsole access–anytypeofconsolecancontrolanytypeof computer;mixedcombinations(PS/2&USB)supportedon boththeconsoleandcomputersides • Compactdesign–rackmountsinonly1Uofrackspace Ease-to-Use Interface • Fullscreengraphicaluserinterface–savesontrainingtime andcosts–increasesuserefficiency • Embeddedwebinterfaceforeasysystemconfigurationand management • Compositetreeview–allconnecteddevicesareintegratedin asingledevicetreeforconvenientmanagementaccessand control • Theportlistautomaticallyexpandswhenstationsareadded –portnamesareautomaticallyreconfiguredwhenthestation sequencechanges • Multilingualuserinterfacesupport–English,German, Japanese,Korean,TraditionalChinese,SimplifiedChinese, Russian Convenient Port Operation • ComputerselectionviaGUIorintuitivehotkeycombinations • Portlevelaccesscontrol–userscanonlyaccesstheports theyhavebeenauthorizedfor–whetherinasingle-stationor multi-stageinstallation • Userscanaccessfeaturesonmultiplecomputers simultaneously–ausercanbeworkingandlisteningto musiconcomputer1whileutilizingvirtualmediaoncomputer 2atthesametime. Diagram • Versatileportoperationmodesforflexibleserver management: • Broadcastsupportenablesexecutingthesamecommandon multipleserversatthesametime Management • Supportsupto1024userand255groupaccounts • Threelevelpasswordsecurity:SuperAdministrator, Administrator,User • Stringentpasswordpolicyfeaturesthatincludepassword expiration;requiredpasswordchanges,accountdisabling, andaccountexpiration. • IntelligentPathAssignment–amasterstationcanallocate thebestavailablepathfortheuserundermulti-path cascadinganddaisy-chaining • PowerOvertheNET™integrationforpowercontrol • PowerAssociationenablestheswitch’sKVMportstobe associatedwithaPN0108’spoweroutletsforremotepower managementoftheserversfromtheswitch’sinterface • RS-232portloginsupportpermitsanadministratortocontrol theKVMportaccessforallconsolesconnectedtoswitch– anyconsolecanbeassignedtoaccessanyKVMportfroma singleinterfacepoint • SessionManagement–aKillSessionfunctionprovides administratorswiththeabilitytoforceuserlogouts • Backupandrestoreofconfigurationsettingsanduser accountinformation • Firmwareupgradescanbeperformedsimultaneouslyon alldaisychainedandcascadedslaveswitchesaswellas connectedadaptercables • AdapterID–adaptercable’sconfigurationinformationis storedwiththeadapter–noneedtoreconfiguretheadapter whenmovingaservertoanewport • EventLogsupport Virtual Media • VirtualMediasupportletsyoumapstoragemediatoservers thatareconnectedtotheswitchallowingoperatorsto conductfiletransfers,installapplicationsandOSpatches, andperformdiagnosticsfromasingleconsole • WorkswithUSBenabledserversattheoperatingsystemand BIOSlevels • SupportsDVD/CDdrives,USBmassstoragedevices Video • User’sdisplayautomaticallyadjuststoresolutiondifferences ontheremoteservers • Superiorvideoquality–1280x1024@60Hzforupto300m • AutoSignalCompensation(ASC)assuresoptimumvideo resolutionfordistancesupto300mbetweencomputersand consoles–noDIPswitchsettingrequired • Enhancedvideoqualityviaautomaticskewcompensation supportfortheKA7240consolemodule,andthenewerKVM adaptercableseries(KA7120,KA7170,KA7130,KA7176) 40 In-Line Power Monitoring Solutions RemotePower&EnvironmentalMonitoring RacSense® Master Feature Benefit Remotepowermonitoring Preventdown-timewithearlynotificationofusageexceedinguserdefinedlimits 5on-boardclimatesensors Currentstatusandtrenddataforenvironmentalconditionsincludingtemperature,relativehumidity, airflow,lightandsound 4remoteclimatesensorports Monitortemperature,airflow,humidityanddewpointviaconnectedsensors(optional)* 3I/Osensorports Abilitytomonitorcontactclosuredevicesorscale0-5Vsignalssuchasdoorposition,waterdetection (optional)* Thresholdalarms(remote&local) Immediatenotificationviae-mail,SNMPtrapsand/orlocalaudiblealarm(GRSD2X8foraudible) Remotedisplay(GRSD)port Easilyviewablepower&climatedataviaGRSD2X8 Accessibleviaanywebbrowser Simpleinstallation,Noexternalsoftwaretoload InterfaceswithIPwebcameras Visualmonitoringofcabinetorcomputerroom *Foracompletelistofoptionalsensorsvisitwww.geistintl.com Specifications InternalEnvironmentalSensors -Temperature:-55Cto79C,+/-.5C -Humidity:0-100%,+/-5% -AirFlow:0-99,relative -SoundLevel:0-99,relative -LightLevel:0-99,relative G L pa ERrt 103 #: G1 PS6 13 -10 PS 6 Amps 10 16 16 32 Volts 230 230 230 230 C-20/C-19 2P+E,16A, 250V 2P+E,32A, 250V IEC309InputSocket/ C-14/C-13 OutputConnector • 6R 6R pa ERrt 102 #: G1 PS6 13 -10 PS 5 GL pa ERrt 102 #: G1 C19 13 -10 4 C2 GL G L pa ERrt 101 #: G1 C13 13 -10 3 C1 0R • RemoteDisplay(RSD2X8) -ConnectionJack • ExternalSensorConnectionPorts -FourRJ12Jacks (addupto16remotesensors) -ThreeI/OPorts -0-5VDCanalogorcontactclosure 4R • InternalPowerSensors -VoltsRMS:80-280VAC -AmpsRMS:0-32A • PowerOnIndicator • IdleIndicator • ActivityIndicator • SoftwareResetButton Input / Output Power Leads 3m 3m 3m 3m DimensionsH(mm) 44 44 44 44 DimensionsW 432 432 432 432 DimensionsD 114 114 114 114 41 Local & Remote Current Monitoring Local&RemoteCurrentMonitoring Ethernet Meter Instantaneouscurrentfeedbackidealforinstallation&maintenance SNMPtrapsandalarms IntegrationintoSNMPsystemsforremotenotification User-friendlyGUIinterface Quicklylocatepertinentinformation IPaddressresetbutton EaseofreconfigurationuponmoveorlossofIPaddress Accessibleviaanywebbrowser Simpleinstallation,Noexternalsoftwaretoloadorlose G L pa MErt 10 #: 3P G1 S6 12 -10 PS 0 G L pa MErt 10 #: 2P G1 S5 11 6-1 9 0P 6S G L pa MErt 10 #: 2P G1 S6 11 -10 8 PS G L pa MErt 10 #: 2C G1 19 11 -10 C2 7 G L pa MErt 10 #: 1C G1 13 11 -10 C 6 Amps 10 16 16 16X3~ 32 32X3~ Volts 230 230 230 230/400WYE 230 230/400WYE C-14/C-13 C-20/C-19 2p+E,16a, 250v 3p+N+E,16a, 230/400v 2p+E,32a, 250v 3p+N+E,32a, 230/400v Input/OutputPowerLeads 3m 3m 3m 3m 3m 3m DimensionsH(mm) 89 89 89 89 89 89 DimensionsW 312 312 312 312 312 312 DimensionsD 51 51 51 51 51 51 IEC 309 Input Socket / Output Connector Specification:+/-2%AccuracywithFullScale50/60Hzsinewaveinput 42 6S Preventdown-timewithearlynotificationofusageexceedinguserdefinedlimits Localcurrentmonitoring(digitaldisplay) S5 6S Remotecurrentmonitoring 0S Benefit 14 S Feature Basic Local Power & Current Monitoring BasicLocalPower&CurrentMonitoring PM-1 & CM-3 Instantaneouspower&currentfeedbackidealforinstallation&maintenance 10 Volts IEC 309 Input Socket / Output Connector 16 L pa AL-1 rt #: 03PS G1 56 13 -10 2 PS G G L pa CL-1 rt #: 03P G1 S613 10P 1 S G G L pa AL-1 rt #: 02PS G1 56 13 -10 0 P L pa CL-1 rt #: 02P G1 S612 10P 9 S 16 6R 6R R G G L pa CL-1 rt #: 02C G1 1912 10C 8 20 L pa CL-1 rt #: 01C G1 1312 10C 7 14 Amps 56 R Localpower/currentmonitoring(digitaldisplay) S5 6R Benefit R Feature 16X3~ 32 32X3~ 230 230 230 230/400 230 230/400 WYE C-14/C-13 C-20/C-19 2p+E,16a, 250v 3p+N+E,16a, 230/400v 2p+E,32a, 250v 3p+N+E,16a, 230/400v Input/OutputPowerLeads MeterType 3m 3m 3m 3m 3m 3m Pm-1 Pm-1 Pm-1 Cm-3 Pm-1 Cm-3 41 41 41 41 41 41 432 432 432 432 432 432 DimensionsD 41 41 41 41 41 41 Amps Volts IEC309InputSocket/Output Connector Input/OutputPowerLeads MeterType 10 16 16 16X3~ 32 230 230/400 WYE 2p+E,32a, 250v 3p+N+E, 32a, 230/400v 6S S5 GL pa AErt 103 #: P G1 S5 12 6-1 6 0P GL pa CErt 103 #: G1 PS6 12 -10 PS 5 6S S5 pa AErt 102 #: P G1 S5 12 6-1 4 0P 6S 16 GL GL pa CErt 102 #: G1 PS6 12 -10 PS 3 0S G L pa CErt 102 #: G1 C19 12 -10 2 C2 0 G L pa CErt 001 #: G1 C19 11 -00 C2 3 G L pa CErt 001 #: 12 C13 41 -00 C1 6 4 6S DimensionsH(mm) DimensionsW 32X3~ 230 230 230 230230/ 400 WYE C-14/C-13 C-20/C-19 C-20/C-19 2p+E, 16a,250v 3p+N+E, 16a, 230/400v N/A N/A 3m 3m 3m 3m 3m Pm-1 Pm-1 Pm-1 Pm-1 Cm-3 Pm-1 Cm-3 DimensionsH(mm) 64 64 64 64 64 64 64 DimensionsW 159 159 210 210 210 210 210 DimensionsD 41 41 51 51 51 51 51 PM-1Specification:+/-2%AccuracywithFullScale 50/60Hzsinewaveinput PM-1:auto-scrolling, PowerFactor,Amps,Volts,Watts CM-3Specification:+/-3.5%AccuracywithFullScale 50/60Hzsinewaveinput CM-3:auto-scrolling, 3PhaseAmpsonlymeter 43 RacSense® Variable Speed Fan Controller (FC-3-2) Maintainoptimalcabinettemperaturewhilereducingfannoise,extendingfanlife andconservingenergy.TheGeistVariableSpeedFanControllertakesreal-time temperaturemeasurementsandautomaticallyadjuststhefanspeedaccordinglyto protectyourequipment. Specification: •Automatedmaintenanceofoptimalcabinettemperature •Webaccessibleremotemonitoringandmaintenance •DualA/Cinput-autoswitchingintheeventofapowerfailure •InstantnotificationalarmsviaSNMPtrap,e-mailand/oraudiblebuzzer •CompatiblewithShadedPoleandSplitCapacitorACfans •Recessed1Uhorizontalmountingwithattachedbrackets •ConserveEnergy •Reducefannoise •UL®&c-UL®Listed60950 •Cordsnotincluded •Chassisdimensions:1.72”Hx17.1”Wx3.52”D Fanspeedautomaticallyadjustsbasedonhighesttemperaturemeasured. 44 RacSense® Variable Speed Fan Controller (FC-3-2) Local Input Local Output •90Vto264V(autosensing) • DualA/Cinput-twoIECC14 -autoswitchingineventofpowerfailure -90-264Voltautosensing • RJ-45ethernetconnection -accessviawebbrowser -directconnectionavailableviacrossovercable •4RJ12jacksforremotetemperaturesensor connection •Fanspeedmanual/localoverrideviarotaryswitch -unplugethernetconnection -setpointchangebuttonmustbepressedwhile activatingrotaryswitch -rotaryswitchwithrecessedscrewdriverslot -manualtemperatureset-pointsof65°-100°F -manualfullonsettingfor100%fanspeed •3IECC13outletsforfanconnection,267watts peroutlet • Fanspeedcontrolof30-100% • Scrollingdigitaldisplayofreal-timemeasurements -setpointtemperature -internaltemperature -fourexternaltemperaturesensors -fanspeedpercentage • Audiblealarmwithsilenceresetbutton • FanrunningvisualindicatorLED’s -speed-runningatalevellessthanFullOn- orangeLED -fanmanuallyoff-orangeLED -remotecontrol-orangeLED -fanFullOn-orangeLED -overtemp-redLED Remote Input Remote Output ThreeLevelsofPasswordProtection •Temperatureset-pointsof65°-100°F • OptionalFullOnsettingfor100%fanspeed • Friendlydeviceandsensornames • CelsiusorFahrenheitselection • Lowandhightriplevelselection • Alarmnotificationselection(SNMPtrap,e-mail and/oraudiblebuzzer) •Real-timemeasurementsandgraph -internaltemperature -fourexternaltemperatures -fanspeed -set-pointtemperature • LogdataavailableforexportviaXMLorreal-time viaSNMP • Eventlogwithvariablecontentsettings • VisualimagedisplayfromoptionalIPaddressable camera • AlarmsviaSNMPtrapore-mail 45 Server Technology® Power Distribution Units If you manage a data center, we have a Cabinet Power Distribution Unit (CDU) solution for you. How do I... Basic CDU Power High Density Server Cabinets? Metered CDU Smart CDU Switched CDU X X X -48VDC CDU Rack-Mount Fail-Safe Transfer Switch Distribute Power in a Cabinet? X X X X X X Provide Branch Circuit Protection? X X X X X X Monitor True RMS current? X X X Distribute and load balance 3-Phase Power? X X X X Receive SNMP based alerts/email alerts? X X X X Know when the cabinet temperature is too high? X X X X X X X Provide fail-safe redundant power? X Link two CDUs on a single IP address? X X X X Instantly connect to an integral web based GUI? X X X X X X X X X X Remote reboot locked up servers and other network devices with graceful shutdown? Monitor, manage & control multiple devices in multiple locations? X Load Shed non-critical devices when UPS goes on battery or temperature /current exceeds defined thresholds X Sentry: Cabinet Power Distribution Unit (CDU) Product Family with Exclusive Integrated Temperature and Humidity Monitoring Basic CDU Cabinet Power Distribution and Branch Circuit Protection Switched CDU Flagship CDU with remote & management, including remote reboot to connected servers and network equipment Metered CDU Cabinet Power Distribution with Local Input Current Monitoring and Branch Circuit Protection -48 VDC CDU DC Cabinet Power Distribution with remote monitoring & management, including remote reboot to connected servers and network equipment Smart CDU Power Distribution with remote monitoring and expanded functionality of SNMP alerts including power, current, temperature and humidity Rack-Mount Fail-Safe Transfer Switch Power Distribution with the expanded functionality of dual A & B input power feeds to supply redundant fail-safe power should an in-feed fail 46 Server Technology® Power Distribution Units Sentry: CDU Product Family The complexity of IT equipment in today’s data centersandremotebranchofficelocationsrequires new solutions for building a solid infrastructure. It must support 24/7 operations and reduce the instance of locked-up or failing equipment leading to network downtime; Five nine’s availability – 99.999%uptime–demandsit. Blade servers and high density computing power requirements continue to increase, creating heat proliferation and more challenges for managing the IT environment. To maintain their competitive advantage, data center managers need SNMPbased solutions that monitor, track and manage servers and IT equipment and the equipment cabinetinfrastructurethathousesthem. ThephotobelowillustrateswhereeachoftheCDU’s keyfeaturesarelocated: Serialaccessfor RS-232andlocal communications. Integrated support for Temperature and Humidityprobes. IP-enabled for Secure Web,SSH&SNMP management IntegratedPower MeteringDisplays perbranchcircuit orphase. UL 60950-1 Branch Circuitprotectionwith ULlistedfuses. The Sentry CDU Family delivers these solutions with three distinct product lines: Metered CDU CabinetPowerDistributionwithLocalInputCurrent MonitoringandBranchCircuitProtection. Centerrailnotchforflush mountingin cabinet. Smart CDU Power Distribution with the expanded functionality of SNMP-based Input Current Monitoring and Temperature/Humiditymonitoring. Switched CDU Completes the solution by adding Full Remote Monitoring & Management, including reboot commands to connected servers and network equipment. 120Vor208V outputforupto84 outputreceptacles. CDU Product Family SolutionsfortheDataCenterEquipmentCabinet Single-phase orthree-phase powerinputfor upto20kW. 47 Server Technology® Power Distribution Units Branch Circuit Protection Metered CDU: The Sentry CDU Family meets the new UL 60950-1 requirementforbranchcircuitprotection. Key Features Attention!TheSentryCDUproductsmeettheUL60950-1criteria byprovidingovercurrentprotectionwithUL–listedBussman®SC fusesforeachbranchcircuit. TheSentryMeteredCDUproducts provide reliable power distribution forallthedevicesinyourequipment cabinet,from5,000toover20,000 Wattspercabinet. Input Current Monitoring The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments.LEDdigitaldisplaysontheCDUenclosure reporttheinputcurrentofeachphaseorbranchcircuit. Single-phase 110-120V or 208240V power distribution with 20A or 30A options -or- 3-Phase 208240V;20Aor30Apowerdistribution options. Button Mounting Local input current monitoring allows the installation engineer to verify the aggregate load on the circuitorphase. All CDU’s are also compatible with button mounting. Severalcabinetmanufacturersarenowusingthismethod forinstallingpowerdistributionunitsinthecabinet. Sentry: Metered CDU Power Distribution with Input Current Monitor LED Horizontal CDU’s C-10H1 C-12H2 C-24H2 100-120V(2.4-3.6kW)/20Aor30A 208-240V(4.2-6.2kW)/20Aor30A 208-240V(4.2-6.2kW)/30A (1U;5inDepth) (1U;5inDepth) (1U;5inDepth) Blade Server Horizontal CDU’s 48 C-4H C-12HD 208-240V(4.2-6.2kW)/20Aor30A 3-Ph,208-240V(14.4-21.6kW)/20Aor30A (1U;7inDepth) (2U;10inDepth) Server Technology® Power Distribution Units Smart CDU: Key Features The Smart CDU products provide reliablepowerdistributioncombined withremotepowerandenvironmental monitoring. Use the network interface to view power, temperature and humidity levels via Web browser, or receive SNMP-basedalarmswhenconditions exceeddefinedthresholds. Trends Impacting Data Center Power Distribution • Morehigh-density,multipleunits fillingracksandcabinets. Branch Circuit Protection Button Mounting Input Current Monitoring Temp & Humidity Monitoring Sentry: Smart CDU Power Distribution with LED’s, IP-based Power, Environmental Monitoring Blade Server Horizontal CDU’s •Moresystemswithhigherand increasingpowerdensity. •Moreuseofhigherrated suppliestoreducecablingcosts. • Moreuseofintelligentpower andmetering. • More3-Phaseapplicationsand increaseduseofmeteringto insureloadbalancedphasesin suchsystems. CS-12HD2 CS-12HD3 208-240V(8.4-12.4kW)/20Aor30A 3-Phase(14.4-21.6kW)/20Aor30A (2U;10inDepth) (2U;10inDepth) Zero-U Modular 3-Phase Verticals • Moresystemswithhigher nominalinputvoltageratings (208Vvs.traditional120V). • Moreindividualpowerdistribution unitsbeingprovidedwithan increasingnumberofoutlets. • Moreglobalpowerdistribution equipmentbeingdevelopedat 20Aand30A. • MoreuseofIEC60320outlets, especiallyforaglobalproduct with208Vnominalsupplyratings. (Source:IEEE) CW-3 CX-3 CB-8V2-A30-D1 3-Ph,208-240V/ 30Aor60A 3-Ph,208-240V/ 30Aor60A 208-240V 10.8-21.6kW 10.8-21.6kW N/A 49 Server Technology® Power Distribution Units Switched CDU: Key Features TheSwitchedCDUproductsprovide thecapabilitytomonitorandcontrol cabinet power remotely for a date centerorremotebranchoffice.The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual power serverwithonecommand.Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign specific access rightstodesignatedusergroupsor individuals. Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amperage, high voltage, UL 60950-1 Branch Circuit Protection and SNMP traps including current monitoring. Switched CDU: Expansion Module The Expansion Module CDU CX is our exclusive method for linking outlets on different power circuits together.ACXlinkstoanySwitched CDU, increasing the number of managed outlets on a single IP address. Control individual outlets oneithertheSwitchedCDUorCX, orcontrolgroupedoutletsbetween theSwitchedCDUandCXwithone command. EachCXlinkstoaSwitchedCDU, whichcontainsbothnetworkand serialinterfaces.Whenlinked toaSwitchedCDU,theCX’s outletsareauto-discoveredbythe SwitchedCDU’sfirmware,andall availableoutletsareviewable andcontrollable throughthe A-Feed B-Feed firmware. (CW) (CX) EachExpansion ModuleCDU canbea single-power feedhorizontal enclosureor asingleor dualpower feedzero-U enclosure. 50 Input Current Monitoring Temperature and Humidity Monitoring Linkable Expansion Module Button Mounting Branch Circuit Protection with Fuse Retractor Sentry: Switched CDU Solutions for Remote Access, Rebooting, and Power Cycling of any attached device, anywhere in the world. Horizontal CDU’s CW-2H1 CW-8H1 100-120V(2.4kW)/20A 100-120V(2.4-3.6kW)/20Aor30A (1U;4.75Depth) (1U;10inDepth) CW-2H2 CW-8H2 208-240V(4.2kW)/20A 208-240V(4.2-6.2kW)/20Aor30A (1U;4.75Depth) (1U;10inDepth) Server Technology® Power Distribution Units Sentry: POPS Switched CDU Power Distribution Solutions for the Data Center Equipment Cabinet Cabinet Power Distribution Unit with Per Outlet Power Sensing Sentry POPS (Per Outlet Power Sensing) combines all the features and functions of a Switched CDU with theabilitytoprovidepowermonitoringperanindividual outlet/device. Power information per individual outlet / device includes current, voltage, power (kW), apparent power,crestfactor,andpowerfactor.Usingourgrouping technology, power information is available per device, groups of devices (application), individual CDU or cabinet. Integral Web Interface The Sentry POPS CDU is capable of being accessed througheitherasecurenetworkorserialconnection.The secureintegralwebinterfaceprovidesasimpleandeasy waytoconfiguretheCDU. Configurationchoicesinclude,SNMPtraps,emailalerts, grouping,andallsecurityandcommunicationsettings. Features • Simple,secure,integralwebinterfaceGUI configurationtool • TemperatureandHumiditySupport • Authenticationlogging,configurationchangesand systemevents • SecureSyslogprotocolsupport • Emailnotificationsoflog,event,authorization,power andconfigurationmessages • AutomaticFirmwareUpdatesviaFTPserver • StrongPasswordSupportandPre-LoginBanner • AbilitytoPinganIPaddresstoseeifthedeviceis responding • GroupingofoutletsacrossmultipleCDU’s • SNMP:TrapsbasedonStatus,Changes,Load, TemperatureandHumidity • Supports104useraccountsand18simultaneous loginswithadedicatedSNMPconnection 51 Server Technology® Power Distribution Units Switched CDU: Access, Security & Communication Secure Remote Administration Interface • Easy to use secure, integral, web based GUI configuration tool • Temperature Support (Celsius or Fahrenheit) • Logging of all authentications, configuration changes and system events • SYSLOG logging protocol support • Email notifications for multiple users of log, event, authorization, power and configuration messages • Automatic Firmware Updates via FTP server • Strong Password Support and Pre-Login Banner New “Power” Information Communication Tools > Input Feed Voltage (VAC) > Web Interface (HTTP, HTTPS) > Input Feed Watts (W) > SSL, SSH, Telnet, SNMP, and Serial RS-232 Access with Scriptable Command Line Interface > System total Watts (W) > System footprint (sq. ft.) > System watts per square foot (W per Sq. ft.) Other Communication Tools > LDAP, LDAPS, TACACS+, and DHCP Sentry: CDU Smart Load Shedding Load Management based on Temperature, Infeed Load, and UPS Status • Easy to use, integral, web based GUI configuration tool • Logging via SYSLOG of all load shedding actions • “Auto-recovery” with a reboot delay time when conditions return to normal • Regular polling of UPS power state via SNMP • Each CDU outlet is assigned the IP address of the connected device for shut down notification • Remote shutdown agent for orderly server shut down • SNMP trap notifications • SMTP based email load shedding event notification 52 Load Shedding Server Technology is the first to offer data center managers the ability to automatically manage CDU power outlets based on key operating parameters, including temperature, in-feed load, and UPS power status. Each outlet may be controlled by one or more of these parameters. Should the temperature or load current exceed defined thresholds or the UPS lose power and go onto battery, all or a portion of the loads may be automatically shed to ensure longer operational life of your critical devices. If one or more servers are being shed, a controlled shut down may be accomplished via a remote shutdown agent. An “auto-recovery” function ensures that all devices are brought back to a defined state when conditions return to normal. Server Technology® Power Distribution Units Switched -48 VDC: Key Features • Remote Power Management: Combinesintelligentpower distributionandremotepower controlintoasingle2U,19” rack-mountenclosure • Qty (2) 100-Amp DC Power Input Feeds (AFeed&BFeed):Supports dualpowersupplyroutersand networkinggear • Multiple DC Outlet Circuits: Switched -48 VDC Power Distribution TheSentrySwitched-48VDCCabinetPowerDistributionUnit(CDU)minimizes the impact of locked-up routers , servers and other network devices for mission criticalnetworks.CLECs,ILECsandISPsuseSentry-48VDCCDU’stomanage equipment in remote sites, co-location facilities and network operations centers. Remotedevicesthatarelocked-upcanbeeasilyrebootedwithouttheneedtosend a technician to the site. Key applications include power distribution and remote managementforacabinetwith-48VDCpoweredserversandhigh-amprouters. The Sentry -48 VDC switched products provide power distribution and remote powermanagementinacompact2U,19”rack-mountenclosure. Other features include sequenced power up to avoid current inrush problems, groupingofoutputstoensurethatmultiplesupplydevicescomeupatthesame time acrossA and B power feeds, and linking for cost savings and doubling the numberofoutputsavailableonasingleIPaddress. EachpoweroutputterminalisprotectedbyaGMTorTPCfuseoracircuitbreaker. Thereisawidefusecapacityrangeavailable. ProtectedbyGMTorTPCfuses • Outlet Circuit Protection: Fastactingfusewithpositive visualindicationofablownfuse Sentry: -48 VDC Applications • Variable Amperage and Interchangeable Fuses: Matchthefusevaluetotheamp ratingofeachoutletcircuit Shown left are 2 Sentry 4805/35XLS-12unitsconnectedtoarouter aswellasseveralotherlowcurrent -48 VDC devices. Dual power infeeds ensure that a loss of either theAin-feedortheBin-feedwillstill allowtherouterandotherdevices to operate on a single supply untiltheproblemisresolved.This provides redundancy and allows for system maintenance without serviceinterruption. • IP Access: ForRemotePowerOn,Power Off,orReboot • Communications and Security: 10/100BaseTEthernet,HTTP/ HTTPS,SSLv3/TLSv1,SNMP, SSHv2,Telnet,LDAPv3, TACACS+,andserialport access • SNMP Traps: Automatedalertsforpowerand environmentalconditions • PSTN: Optionalintegratedsecure globalmodem. • Environmental Monitoring: TwooptionalTemperatureand Humidityprobes(notavailable on4820XLSor4835XLS) 4870-XLS-4 (Master) XLS<••>XMS Data Link Cable • Load Sense: Realtimereportingofthe currentdraw,inamps,foreach poweroutlet • On Sense: VerifyvoltageattheDCpower outletcircuit • Expansion Units: EachSentryIntelligent-48VDC XLSlinkstoanXMS-48VDC unit Shownleftare2Sentry4870-XLS/ XMSunitsconnectedtoarouterwith dual power supplies. Each router powersupplycontainsthreeinputs. Twoin-feedsourceswithanH-Tap provide power to the 4870 units. Point of failure and maintenance concerns are eliminated by wiring one supply to the XLS and one to the XMS allowing removal or replacement of either Sentry unit withoutinterruptingoperationofthe router. 4870-XMS-4 (Expansion/ Redundant Unit) 53 Server Technology® Power Distribution Units SentryTM Power Manager Manage Multiple Cabinet Power Distribution Units (CDUs) in Multiple Locations Key Features • ViewyourentiresystemofCDU’s fromaglobalviewdowntotherack level • Auto-DiscoversallyourSentryCDU devices • AccessviaStandardNetwork Browser • OutletClusters-Groupoutlets withinaCDU,acrosstwoCDU’sor acrossIPaddresses • Logs&Reporting:detailedevent log,devicedetailreport,current report,andpowerreports • IntegratedRemoteManagementof SentryCDU’stocyclepowerand rebootselecteddevices • CentralisedEventLogging • Trendingoftemperature,humidity, power(kW)andcurrentinamps • Simpleandeasytounderstand alarmnotificationand acknowledgement • Realtimealarmnotification • MultipleViews:Temperature, humidity,amps,anddevicestatus • IntegratedRemoteManagementof SentryCDU’stocyclepowerand rebootselecteddevices • EmailnotificationsviatheCDU wheneventsoccur • SNMPtrapssentviatheCDUwhen eventsoccur • Abilitytoimportimages • Multipleuserlevelsandpermissions “Quickly drill down from a global view to the rack level” DoyouhavemultipleSentryTMCDUsinoneormorelocationsthatyouwould like to access from one central point? Would you like one central location whereallalarmscanbeviewedandloggedforreporting,emailorSNMPtrap notifications?Noproblem! OurSentryPowerManger(SPM)productiscapableofmonitoringandmanaging multiple Sentry devices in IP-based enterprise networks. SPM provides a globalviewofallSentryCDUsalongwiththeabilitytoviewdevicesbasedon theirtemperature,humidity,currentanddevicestatus.Besidesmanagingand monitoring all alarm conditions, this information can also be used to provide reportingandtrendinginformation. Sentry: Additional Features IP Addressable Remote Power Management that combines intelligent power distribution and remote power control. IPAccess forRemotePowerOn,PowerOff,orReboot. Temperature and Humidity Monitoring Supportstwoexternaltemperatureandhumidityprobes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds (NotAvailable on the4820or4835Models). HTML GUI Interface Sentry Switched -48 VDC products can be monitored remotelythroughtheintegralGUIInterface. 54 Cisco® Switches Product Positioning The Cisco® Catalyst® family of fixed-configuration, standalone Ethernet switches supportsenhancedswitchingservices,IPcommunications,andwirelessnetworking for small businesses. These switches provide the performance, availability, and manageabilitythatmodernofficeenvironmentsdemand,aswellastheintelligence tosupportstate-of-the-artbusinessapplicationsandsecurityservices. Cisco Catalyst switches provide: •FastEthernetandGigabitEthernetconnectivitytothedesktoptodeliver superiorapplicationperformance •PoweroverEthernet(PoE)toprovide15.4WonallPoEports •Differentlevelsofadvancedsecuritycapabilities,includingidentityservicesand sophisticatedaccesscontrol,toprotectcriticalassets •Differentlevelsofqualityofservice(QoS)intelligencetosupportdelay-sensitive IPvoiceandvideoapplicationsandoptimizebandwidthinthenetwork •Redundancyandresiliencyfeaturestoprotecttheavailabilityofcritical applicationsatalltimes •Simple,scalablemanagementwiththeoptiontouseacommand-lineinterface (CLI)ortheGUI-basedCiscoNetworkAssistantwithCiscoSmartports interfaces •Scalabilitytocontinuallyaccommodatenewapplicationsandservicesasthe businessevolves Basic Layer 2 Switches Common Features •FastEthernetandGigabitEthernetinupto8-,554-,and48-portconfigurations •Basicsecurity,basicQoS,standardavailability,andmulticastfeatures (CiscoCatalystExpressandLANLiteimageforCiscoCatalyst55960Series Switches) •Lowertotalcostofownership(TCO)duetoscalableandsecurenetwork managementandsimplifiedtroubleshooting CatalystExpress500/520Series •Limitedlifetimehardwarewarranty,andsoftwareupdatesatnoadditional charge Enhanced Layer 2 Switches Common Features •FastEthernetandGigabitEthernetin8-,24-,and48-portconfigurations •PoEconfigurationswithupto15.4Wonupto48ports •Networkcontrolandbandwidthoptimization,deliveredviaadvancedQoS,rate limiting,accesscontrollists(ACLs),IPv6management,andmulticastservices •Enhancedsecuritytoprotectusersanddevicesfromattackviaawiderangeof authenticationmethods,dataencryptiontechnologies,andNetworkAdmission Controlsupportbasedonusers,ports,andMACaddresses(LANBaseimage) Catalyst2960LANLiteSeries •SimplifiednetworkavailabilitywithfeaturessuchasFlexLinks,LinkState Tracking,andsupportforaredundantpowersupply •LowerTCOduetoscalableandsecurenetworkmanagementandsimplified troubleshooting •Limitedlifetimehardwarewarranty,andsoftwareupdatesatnoadditional charge Catalyst2960LANBaseSeries 55 Cisco® Switches Layer 2 and Layer 3 Switches Common Features •Enterprise-class,fixed-configuration,multilayerswitches •FastEthernetandGigabitEthernetconfigurationswith1Gigabitand10Gigabit uplinks •SupportforIEEE802.3afandCiscoprestandardPoE •Abilitytodeploynetworkwideintelligentservicesforconvergedapplications •Enhancedsecurity,advancedqualityofservice(QoS),andhighavailability •Intelligentpowermanagementfeatures,providinggranularcontrol •ExpressSetupandCiscoNetworkAssistantsoftwareforeasydeploymentand configuration •Ciscoapplication-specificintegratedcircuits(ASICs)forsuperiorhardwareand softwareintegrationandinnovativefeatures •Field-replaceablepowersupplyandfanontheCiscoCatalyst3560ESeries Switches •Limitedlifetimehardwarewarranty,andsoftwareupdatesatnoadditional charge(Catalyst3650and3750;doesnotincludeESeries) Catalyst3560and3560ESeries TheCiscoCatalyst3650SeriesSwitchesareavailablewitheithertheIPBase orIPServicessoftwareimagesandcanbeupgradedtotheAdvancedIP Servicessoftwareimage •TheIPBasesoftwareincludesadvancedQoS,ratelimiting,ACLs,andbasic routingandIPv6functionality. •TheIPServicessoftwareprovidesarichersetofenterprise-classfeatures, includingadvancedhardware-basedIPunicastandIPmulticastroutingaswell aspolicy-basedrouting(PBR). •TheAdvancedIPServicessoftwareincludessupportforIPv6routingandIPv6 ACLs Layer 2 and Layer 3 Switches with Stacking Common Features •Enterprise-class,fixedconfiguration,multilayerswitchingline •FastEthernetandGigabitEthernetconfigurationswith1Gigabitand10Gigabit uplinks •SupportforIEEE802.3afandCiscoprestandardPoE •Abilitytodeploynetworkwideintelligentservicesforconvergedapplications •Enhancedsecurity,advancedqualityofservice(QoS),andhighavailability Catalyst3750and3750ESeries •Intelligentpowermanagementfeatures,providinggranularcontrol •ExpressSetupandCiscoNetworkAssistantsoftwareforeasydeploymentand configuration •CiscoASICsforsuperiorhardwareandsoftwareintegration,andinnovative features TheCiscoCatalyst3750isavailablewitheithertheIPBaseorIPServices softwareimagesandcanbeupgradedtotheAdvancedIPServicessoftware image. •TheIPBasesoftwareincludesadvancedQoS,ratelimiting,ACLs,andbasic routingandIPv6capability. •TheIPServicessoftwareprovidesarichersetofenterprise-classfeatures, includingadvancedhardware-basedIPunicastandIPmulticastroutingaswell asPBR. •TheAdvancedIPServicessoftwareincludessupportforIPv6routingandIPv6 ACLs. 56 Cisco® Switches Layer 2 and Layer 3 Switches Decision Tree Overview Yes Enhanced IPServices Software?3 Yes Gigabit Ethernet Switch No GigabitEthernet Switchesw/PoE,GE Uplinks&Enhanced IPServicesSoftware GigabitEthernet SwitcheswithPoE& GEUplinks WS-C3560G-48PS-E 48-port GE Switch with PoE + 4 GE SFPportswithIPServiceimage WS-C3560G-24PS-S 2 4-port GE Switch with PoE + 4 GE SFPportswithIPBaseimage WS-C3560G-48PS-S 48-port GE Switch with PoE + 4 GE SFPportswithIPBaseimage PoE Capability?1 No Yes Enhanced IPServices Software?3 No Layer2 andLayer3 Switches Yes GigabitEthernet Switchesw/GE Uplinks&Enhanced IPServicesSoftware2 GigabitEthernet SwitcheswithGE Uplinks2 GigabitEthernetSwitch FastEthernet Switchesw/PoE,GE Uplinks&Enhanced IPServicesSoftware2 Enhanced IPServices Software?3 Yes Fast Ethernet Switch WS-C3560G-24PS-E 24-portGESwitchwithPoE+4GE SFPportswithIPServiceimage No FastEthernet SwitcheswithPoE& GEUplinks2 PoE Capability?1 No Yes Enhanced IPServices Software?3 No FastEthernet Switchesw/GE Uplinks&Enhanced IPServicesSoftware2 FastEthernet SwitcheswithGE Uplinks2 WS-C3560G-24TS-E 24-portGESwitch+4GESFPports withIPServiceimage WS-C3560G-48TS-E 48-portGESwitch+4GESFPports withIPServiceimage WS-C3560G-24TS-S 24-portGESwitch+4GESFPports withIPBaseimage WS-C3560G-48TS-S 48-portGESwitch+4GESFPports withIPBaseimage WS-C3560-24PS-E 2 4-port FE Switch with PoE + 2 GE SFPportswithIPServiceimage WS-C3560-48PS-E 48-port FE Switch with PoE + 4 GE SFPportswithIPServiceimage WS-C3560-8PC-S Compact 8-port FE Switch with PoE +1GESFPportswithIPBaseimage WS-C3560-12PC-S 12-port FE Switch with PoE + 1 GE SFPportswithIPBaseimage WS-C3560-24PS-S 2 4-port FE Switch with PoE + 2 GE SFPportswithIPBaseimage WS-C3560-48PS-S 48-port FE Switch with PoE + 4 GE SFPportswithIPBaseimage WS-C3560-24TS-E 24-portFESwitch+2GESFPports withIPServiceimage WS-C3560-48TS-E 48-portFESwitch+4GESFPports withIPServiceimage WS-C3560-24TS-S 24-portFESwitch+2GESFPports withIPBaseimage WS-C3560-48TS-S 48-portFESwitch+4GESFPports withIPBaseimage 57 Cisco® Mobility Express Cisco Mobility Express brings together the Cisco 521 Wireless ExpressAccess PointandtheCisco500SeriesWirelessExpressMobilityControllertoprovidea flexible,cost-effectivewirelesssolutionspecificallydesignedtomeettheneedsof smallbusinesses. TheCisco521accesspointisasingle-band802.11gaccesspointthatfeatures business-class management, security, and scalability. It offers high-performance wirelessconnectivityinofficesandsimilarenvironments. Aspartofthissolution,theCisco521accesspointuniquelyaddressesthediverse requirementsofsmallbusinessesthroughtheabilitytooperateeitherinstandalone mode or in controller-based mode with the Cisco 500 Series Wireless Express MobilityController. • Standalonemode:Accesspointsaredirectlyconnectedtothewiredinfrastructure throughanEthernetswitchandprovidereliablehigh-speedwirelessconnectivity tousersintheareatheycover.Configurationandmanagementareperformed locallyattheindividualaccesspointlevel. • Controller-based mode: Access points are directly connected to the wired infrastructurethroughanEthernetswitchandassociatedwithaCisco500Series WirelessExpressMobilityController.Thecontrollerstreamlinesandmanages theconfigurationofallconnectedaccesspointsthroughasingleinterfaceand providesaplatformformobilityservicessuchassecureguestaccessandvoice overWi-Fi. Common Features • TheCisco521WirelessExpressAccessPointisasingle-band802.11g accesspointandisbackwardcompatiblewith802.11bdevices. • Hardware-assistedAdvancedEncryptionStandard(AES)encryptionprovides ahighlevelofsecuritywithoutperformancedegradation. • TheaccesspointisIEEE802.11icompliantandWi-FiProtectedAccess (WPA2)andWPAcertifiedtohelpensureinteroperablesecuritywithabroad rangeofwirelessLANclientdevices. • PoweroverEthernet(IEEE802.3af)providesaninteroperablealternativeto ACpower. • CiscoConfigurationAssistantsimplifiesthetaskofconfiguringandmanaging theaccesspoints. • TheCisco526WirelessExpressMobilityControllersimplifiesthedeployment andmanagementofmulti-access-pointnetworks • Secureguestaccesscreatesapartitionbetweenthevirtualguestnetworkand thecorporateLAN. • VoiceoverWLANoptimizationdeliversqualityofservice,calladmission control,andfasthandoffsbetweenaccesspointstoimprovethequalityofa wirelessvoiceinfrastructure. 58 HP ProCurve PoE and UC Switch Selection Guide Fixed-Port Modular HP ProCurve switch products 2520series 2610seriesand2615- 2910alseriesand 8-PoEswitch 2915-8G-PoEswitch 3500series 5400zlseries 8200zlseries Ideal environment Idealforsmalland growingbusinesses seekingcosteffectiveswitches withintegratedPoE andmanagement capabilities Idealforenterprise edge,remotebranch offices,andconverged networksrequiring 10/100accessspeeds Idealforenterprise edge,remotebranch offices,andconverged networksrequiring Gigabitaccessspeeds Idealforthose seekingperformance, security,mobility,and convergencecapability inastackableform factor Idealfor environmentsdriven byperformance, security,mobility, andconvergence capability Campuscore, enterprisedistribution, andmission-critical, high-capacity,access layerdeployments Customers’ needs •PoEcapabilityfor poweringIPphones, wirelessAPs,and/or videocameras •Managedswitchwith Layer2functionality witheitherGigabit orFastEthernet connectivity •Optionalfiberuplink capabilitywithSFP slots •Upto8or24portsof PoEconnectivity •Advanced convergence featuresfortoday’s VoIP,wireless networks,and videosurveillance functionallyat wirespeed10/100 performance •ScalablePoE deployment •Upto48portsof PoEconnectivity •Robustnetwork connectivitywith standards-based 10/100connectivity withGigabituplinks •Granularcontrolof networkwithmore accesssecurity, PoE,andtraffic monitoring •Easyintegrationand management •Offersthemost flexibleandeasyto-deployuplinksin itsclass.Together withstaticand RIPIPv4routing, robustsecurity andmanagement, enterpriseclass features,freelifetime warranty*,andfree softwareupdates •Cost-effective, scalablesolution forcustomers whoarebuilding high-performance networks •High-performance Gigabitaccess switch •Fouroptional10Gigabitports(CX4 and/orSFP+)** •IEEE802.3af/802.3at functionality(PoE/ PoE+**) •IPv6hostcapability toprovidetransition fromIPv4and forwardingofIPv6 multicasttraffic •Highlyscalable, enterprise-class switchesthat supportawide rangeofapplications fromGigabittothe desktop,PoEfor IPphones,ACLfor accesssecurity,and virusthrottlingto preventdowntime •Granularcontrolof networkuseraccess andsecuritypolicy tosecurecompany informationassets •Form-factorchoices thatcanfitinto differentnetwork environmentswith consistentfeatures, capability,and management •SwitcheswithGigabit interfaces,10-GbE uplink,androom forfuturesoftware updates •UpgradabletoVRRP andOSPFfor missioncriticalUC deployments •IPv6ready •Common softwarebasefor 3500/5400/8200 foreaseof management •Highlyscalable, enterprise-class switchesthat supportawide rangeofapplications fromGigabittothe desktop,PoEfor IPphones,ACLfor accesssecurity,and virusthrottlingto preventdowntime •Granularcontrolof networkuseraccess andsecuritypolicy tosecurecompany informationassets •Form-factorchoices thatcanfitinto differentnetwork environmentswith consistentfeatures, capability,and management •SwitcheswithGigabit interfaces,10-GbE uplink,roomfor futuresoftware updates,and scalabilitytodifferent configurations forinvestment protection •UpgradabletoVRRP andOSPFfor mission-criticalUC deployments •IPv6ready •Common softwarebasefor 3500/5400/8200 foreaseof management •Platformand softwarehighavailabilityfeatures •Comprehensive hardwareand softwarehighavailabilityfeatures •Scalable,wire-speed Gigabitandhigh density10-GbE connectivity •Long-term investment protection viasoftware andhardware upgradability •Featureflexibility (e.g.,QoScontrols, GigabitPoE)to enabledeployment inawiderangeof deploymentmodels •Management simplicityand reducedcomplexity •Form-factorchoices thatcanfitinto differentnetwork environmentswith consistentfeatures, capability,and management Competitive products •NETGEARFSM72x/ GSM72xSeries •D-LinkDES-3xxx/ DGS-3xxxSeries •CiscoSmall BusinessSRW Series •CiscoCatalyst Express5xxSeries •CiscoCatalyst2960 LANLiteSeries •CiscoSmall BusinessProESW Series •CiscoCatalyst2960 Series •Nortel4500Series •CiscoCatalyst3560 •CiscoCatalyst &3750Series 2960GSeries •Nortel4500GSeries •NortelEthernet Switch5000Series •ExtremeSummit X450Series •NETGEAR GSM7312 •NETGEAR GSM7324 **2910seriesonly •D-LinkDGS-3300 Series •D-LinkDXS-3300 Series •CiscoCatalyst3560 &3750Series •CiscoCatalyst4500 Series •Extreme BlackDiamond8800 •Extreme BlackDiamond6808 •ExtremeSummit X450Series •FoundryFastIron SuperX •NortelEthernet Switch5000 •NETGEAR GSM7312, GSM7324 •D-LinkDGS-3300 andDXS-3300 Series •CiscoCatalyst6500 Series •CiscoCatalyst4500 Series •FoundryFastIron SuperX •Extreme BlackDiamond8800 •NortelEthernet RoutingSwitch8600 Series 59 HP ProCurve PoE and UC Switch Selection Guide Fixed-Port Subcategory 2520-8-PoE/ 2520-24-PoE/ 2520G-8-PoE/ 2520G-24-PoE 2610-24/12PWR 2610-24-PWR/ 2610-48-PWR J9137A/ J9138A/ J9298A/ J9299A J9086A J9087A/ J9089A 3 3 3 3 PoE 10/100 ports 8/24/0/0 12 (of 24) 24/48 8 PoE 10/100/1000 ports 0/0/8/24 Feature Product number Ports, media, and PoE IEEE 802.3af Power over Ethernet 2615-8-PoE IEEE 802.3at Power over Ethernet Plus PoE/PoE+ 10/100 ports PoE/PoE+ 10/100/1000 ports Pre-standard PoE support Maximum PoE power 3 3 3 67 W/ 195 W/ 67 W/ 195 W 125 W 377 W 533 W 785 W Maximum PoE power with EPS Uplink flexibility 67 W HP ProCurve/IEEE Auto-MDIX 3 3 3 3 1-GbE 1000Base-T/Mini-GBIC 2/4/2/4 (3) 4 4 2 10-GbE ports Module slots Performance Routing/Switching capacity 5.6/8.4/20/48 Gbps 12.8 Gbps 12.8/17.6 Gbps 5.6 Gbps Security Multi-user IEEE 802.1X (per port) 2 8 8 2 Multi-role access control (IEEE 802.1X, MAC authentication, Web authentication) 3 3 3 3 Dynamic ARP protection 3 3 3 DHCP protection 3 3 3 Dynamic IP lockdown 3 Virus throttling Management HP ProCurve Manager Plus 3.0 support 3 3 3 3 3 3 3 Remote Intelligent Mirroring (based on ACL, port, MAC, or VLAN) RMON, XRMON, sFlow IEEE 802.1AB Link Layer Discovery Protocol (LLDP) 3 3 3 3 LLDP-MED (Media Endpoint Devices) 3 3 3 3 LLDP-MED fine-grained power control 3 3 3 3 RFC 4675 RADIUS VLAN for voice Command authorization Resilience and high availability Redundant switch fabric and management module Hot-swappable modules Virtual Router Redundancy Protocol QoS IEEE 802.3ad Link Aggregation Control Protocol (LACP) – links per trunk 8 8 8 8 ProCurve trunking – links per trunk 8 24 24 8 IEEE 802.1s Multiple Spanning Tree Protocol (including STP, RSTP) 3 3 3 3 2 or 4 HW queues per port Honor DSCP or IEEE 802.1p priority Assign IEEE 802.1p priority Remap DSCP 2 or 4 4 4 3 3 3 3 Classifier Classifier Classifier Classifier 3 3 3 3 3 3 3 3 Guaranteed minimum bandwidth per port, per queue Prioritization by IP address and UDP/TCP port ranges Multicast Data-Driven IGMP PIM Multicast Routing HP ProCurve Lifetime Warranty Standards-based convergence features PoE (IEEE 802.3af) & PoE+ (IEEE 802.3at) – Ethernet with power, ideal for phones, cameras, and more Wi-Fi WMM – wireless QoS enhancements to support multimedia transport LLDP-MED and RFC 4675 – automates configuration of phones and network settings 802.11e APSD – allows wireless VoIP handsets to support more efficient power management LLDP-MED fine-grained power management – delivers 10-GbE uplink – aggregating to fast pipes ensures just the right amount of PoE to save energy optimal application performance 60 NAC/802.1X – identity-driven security at the edge of the network where users connect sFlow – standards-based sampling technology allows monitoring of network performance IGMP & PIM DM/SM – manages efficient delivery of video and eliminates unnecessary network traffic SVP – SpectraLink Voice Priority is an open, straightforward voice QoS approach • Next-business-day advance replacement included free of charge • Free telephone and Web support • Free software updates HP ProCurve PoE and UC Switch Selection Guide Modular 2910al-24G-PoE+/ 2910al-48G-PoE+ 2915-8G-PoE J9146A/ J9148A 3 3 3500-24-PoE/ 3500-48-PoE 3500yl-24G-PWR/ 3500yl-48G-PWR 5406zl 5412zl 212zl/8206zl J9471A/ J9473A J8692A/ J8693A J8697A J8699A J9447A J8698A J8700A J9448A J8715B/ J9475A 3 3 3 3 3 3 3 3 3 24/48 8 24/48 24/48 3 382 W 3 67 W 3 144 (2) 288 (2) 288/144 (2) 144 (2) 288 (2) 288/144 (2) 3 3 398 W 398 W 1800 W 3600 W 3600 W/1800 W 796 W 796 W 3600 W 5400 W 5400 W/3600 W 3 3 3 48/24 3 3 3 3 4/4 (3) 2 4/4 (3) 4/4 (3) 4 4 24 48 2 1 6 12 12/6 128/176 Gbps 20 Gbps 12.0/16.8 Gbps 101.8/149.8 Gbps 322.8 Gbps 645.6 Gbps 645.6/322.8 Gbps 8 2 32 32 32 32 32 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 8 24 3 3 3 3 3 (1) 3 (1) 3 (1) 3 (1) 3 (1) 8 8 8 8 8 8 8 36 36 36 36 36 3 3 3 3 3 3 8 2 or 4 8 8 8 8 8 3 3 3 3 3 3 3 Classifier Classifier Classifier Classifier Classifier Classifier Classifier 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 SM(1) & DM(1) SM(1) & DM(1) SM(1) & DM(1) SM(1) & DM(1) SM(1) & DM(1) 3 3 Why choose HP ProCurve? (1) Requires premium license Choice and flexibility – performance and interoperability (2) 10/100 or 10/100/100 PoE/PoE+ modules Advanced technology – 30 years of leadership Security and trust – safe and field-tested solutions Proven reliability – backed by a lifetime warranty Return on IT investment – easy to install and use (3) Dual-personality ports For a complete list of these products’ features and other HP ProCurve products, such as intelligent edge switches and WAN, mobility, and network management, please visit www.procurve.com/convergence 61 ANS - Adler Networking Solutions ANS Cat. 6 Keystone Jack ANS-504-180 ANS-504-110 ANS-504E ANS-504S CAT.6RJ45Keystonejack180degree CAT.6RJ45Keystonejack90degree CAT.6RJ45Tool-lesskeystonejack90degree CAT.6RJ45Tool-lesskeystonejack90degree ANS Cat. 6 Patch Panel ANS-508-24K-C6 ANS-508-24PCB CAT.6RJ4524PortRJ45patchpanel(6x4) CAT.6RJ4524PortRJ45patchpanelPCBtype ANS Cat. 5E Keystone Jack ANS-505-WH ANS-505-BL ANS-505-OR ANS-505-GR ANS-505-YL ANS-505-RE ANS-505-BK ANS-505-S ANS-505-180 CAT.5ERJ45Keystonejackwhite CAT.5ERJ45Keystonejackblue CAT.5ERJ45Keystonejackorange CAT.5ERJ45Keystonejackgreen CAT.5ERJ45Keystonejackyellow CAT.5ERJ45Keystonejackred CAT.5ERJ45Keystonejackblack CAT.5ERJ45Keystonejackshielded CAT5.ERJ45Keystonejack180º ANS Inline Couplers ANS-350 ANS-350E8 ANS-350K8 ANS-350KS8 ANS-350G8 ANS-350KG8 ANS-350SG8 CAT.3Inlinecoupler CAT.5EInlinecoupler CAT.5ESnap-incoupler CAT.5EShieldedsnap-incoupler CAT.6Inlinecoupler CAT.6Snap-incoupler CAT.6Shieldedsnap-incoupler ANS Cat. 5E UTP Patch Panel ANS-508-16 ANS-508-24M ANS-508-48M CAT.5E16PortRJ45patchpanel(8x2) CAT.5E24PortRJ45patchpanel(6x4) CAT.5E48PortRJ45patchpanel(6x8) ANS Cat. 5E STP Patch Panel ANS-508S-16 ANS-508S-24 CAT.5ESTP16Portpatchpanel CAT.5ESTP246Portpatchpanel ANS Modular Plugs 62 ANS-RJ-45-x ANS-RJ2-45-5 ANS-RJ2-45-2 ANS-RJ2-45-3 ANS-RJ-45-1 ANS-RJ2-45-1 ANS-RJ3-45-1 ANS-RJ-45 ANS-RJ2-45 ANS-RJ3-45 ANS-FRJ2-45 ANS-FRJ2-45-1 ANS-FRJ2-45-2 ANS-FRJ2-45-S ANS-FRJ2-45-SD RJ452Prong1pin3pcs RJ452ProngYpin3pcs1.3.5.7pinup RJ452ProngYpin2pcs1.3.5.7pinup RJ452ProngYpin2pcs1.3.7pinup RJ452Prong1pin2pcs RJ452ProngYpin2pcs RJ453ProngYpin2pcs RJ452Prong1pin RJ452ProngYpin RJ453ProngYpin RJ452Prong1pinstandard RJ452ProngYpin2pcs RJ453ProngYpin3pcs1.3.5.7pinup RJ452ProngYpinshortbody RJ452ProngYpinshortbody1.3.5.7pinup FibreNet® Fibre Optic Cables PEOuterJacket FlexibleStrengthElements 6.0mmBufferTube SuperLAN Cable 2-96FibreConstruction,CentralTube with12-fibreBundles RipcordforJacketAccess(2) Gel FibreBinderThreads 250micronFibres PEOuterJacket Ripcord(1) StrengthElements Binder WaterSwellableTape Heavy Duty Duct Cable 2-288FibreConstruction,Stranded LooseTubewith12-fibreSubunits 3.0mmGelFilledBufferTubes Binder 250micronFibres FRPStrengthMember PEOuterJacket AramidStrengthElements Ripcord(1) Binder WaterSwellableTape 3.0mmGelFilledBufferTubes Binder 250micronFibres FRPStrengthMember PEOuterJacket SteelArmor RipcordforJacketAccess(2) All-Dielectric Self Supporting ADSS Cable 2-60FibreConstruction,Stranded LooseTubewith12-fibreSubunits SHORTSPANSofupto249meters ArmoTube Cable 2-96FibreConstruction,CentralTube with12-fibreBundles 6.0mmBufferTube RipcordforArmorAccess(2) Gel FiberBinderThreads 250micronFibres PEOuterJacket SteelTapeArmoring WaterBlockingTape PEInnerJacket Ripcord(2) StrengthElements Binder WaterBlockingTape Ripcord(1) Binder 3.0mmGelFilledBufferTubes 250micronFibres DielectricStrengthMember PEOuterJacket SteelTapeArmoring WaterBlockingTape PEInnerJacket SteelTapeArmoring Ripcord(2) WaterBlockingTape PEInnerJacket StrengthElements Binder Ripcord(2) Binder WaterBlockingTape Ripcord(1) 3.0mmGelFilledBufferTubes FRPStrengthMember 250micronFibres Corrugate Steel Tape (CST) Cable 2-288FibreConstruction,Stranded LooseTubewith12-fibreSubunits Double Corrugate Steel Tape (CST) Cable 2-288FibreConstruction,Stranded LooseTubewith12-fibreSubunits 63 FibreNet® Connectors & Adaptors ST Connector Utilize a bayonet style mating concept to provide a secure, robust coupling mechanism. The enclosed spiral slotted coupling nut allows easy insertion in densely packed patch panels. The ST connector has been used extensively in telecom,dataandpremiseinstallationapplicationsandcould easilybeconsideredadefactostandard. ST Adaptor • STtypefiberopticadaptorforconnectorwithST/PC patchcord. SC Connector Utilize a push pull retention feature enabling easy insertion andremoval,makingitideallysuitedforhighdensity. The SC connector features an internal cavity that virtually eliminatesthepossibilityofimproperepoxyapplication,thus providinghighermanufacturingyields. SC Adaptor SC Simplex SM Adaptor SC Duplex MM Adaptor LC Connector These connectors utilize the familiar RJ-45 style latching mechanism.Asasmallformfactor(SFF)connector,theLC connectorisalmosthalfthesizeofthepopularSCconnector. With accelerated growth demanding greater bandwidth in lessphysicalspace,LCconnectorshaveemergedasaviable solutionforhighdensityframesandpatchpanels. LC Adaptor 64 Proudly South African Certification 65 SABS Certification 66 SABS Power Duct Certificate 67 Glossary EIA/TIA ElectronicIndustriesAllianceandtheTelecommunicationsIndustryAssociation. FDDI FibreDistributedDataInterface.LANstandard,definedbyANSIX3T9.5,specifyinga100Mbpstoken-passingnetworkusingfibre-opticcable,withtransmissiondistancesofupto2km. FDDIusesadual-ringarchitecturetoprovideredundancy.ComparewithCDDIandFDDIII. FibreOptics Amethodforthetransmissionofinformation(audio,video,data).Lightismodulatedand transmittedoverhighpurity,hair-thinfibresofglass.Thebandwidthcapacityoffibreopticcable ismuchgreaterthanthatofconventionalcableorcopperwire. FibrePlant Aerialorburiedfibreopticcablethatestablishedconnectivitybetweenfibreoptictransmission equipmentlocations. FIA FibreopticIndustryAssociation. (FIA)CDT FibreCertifiedDesignTechnician. (FIA)CDS FibreCertifiedDesignSpecialist. Hub 1.Generally,atermusedtodescribeadevicethatservesasthecenterofastar-topology network. 2.Hardwareorsoftwaredevicethatcontainsmultipleindependentbutconnectedmodulesof networkandinternetworkequipment.Hubscanbeactive(wheretheyrepeatsignalssent throughthem)orpassive(wheretheydonotrepeat,butmerelysplit,signalssentthrough them). 3.InEthernetandIEEE802.3,anEthernetmultiportrepeater,sometimescalleda concentrator. ISO InternationalOrganisationforStandardisation.Internationalorganisationthatisresponsible forawiderangeofstandards,includingthoserelevanttonetworking.ISOdevelopedtheOSI referencemodel,apopularnetworkingreferencemodel. ISO9000 Setofinternationalquality-managementstandardsdefinedbyISO.Thestandards,whichare notspecifictoanycountry,industry,orproduct,allowcompaniestodemonstratethattheyhave specificprocessesinplacetomaintainanefficientqualitysystem. Multiplexing Schemethatallowsmultiplelogicalsignalstobetransmittedsimultaneouslyacrossasingle physicalchannel.Comparewithdemultiplexing. Network Anetworkisgroupoftwoormorecomputersorcomputersystemslinkedtogether.Thereare manytypesofcomputernetworks,including: Switch LANs(local-areanetworks): Thecomputersaregeographicallyclosetogether(thatis,inthe samebuilding) WANs(wide-area networks): Thecomputersarefartherapartandareconnectedbytelephone linesorradiowaves. CANs(campus-area networks): Thecomputersarewithinalimitedgeographicarea,suchasa campusormilitarybase. MANs(metropolitan-area networks): Adatanetworkdesignedforatownorcity. HANs(home-area networks): Anetworkcontainedwithinauser’shomethatconnectsa person’sdigitaldevices. 1. Networkdevicethatfilters,forwards,andfloodsframesbasedonthedestinationaddressof eachframe.TheswitchoperatesatthedatalinklayeroftheOSImodel. 2. Generaltermappliedtoanelectronicormechanicaldevicethatallowsaconnectiontobe establishedasnecessaryandterminatedwhenthereisnolongerasessiontosupport. 3. Intelephony,ageneraltermforanydevice,suchasaPBX,thatconnectsindividualphones tophonelines.SeealsoPBXandPSTN. UL UnderwritersLaboratories.IndependentagencywithintheUnitedStatesthattestsproduct safety. 20-AmpPowerInput Support 20-ampPowerInputSupport.IEC320/C20powerinletreceptaclessupportsanypowercord withIEC320/C19powerconnector(PTCORD-XX). 3PhasePower 3phasepowerdistributionforhigh-density,high-powerdemandequipmentcabinets.Input currentmonitoringofeachphaseallowsforproperloadbalancingofeachrackmountpower distributionunit.SwitchedunitsprovideremotepowermanagementwhileSmartunitsprovide remotepowermonitoringandMeteredunitsprovidelocalinputcurrentmonitoring. The-3Phextensiononaproductindicatesa3Phasepowerproduct. 3-PhaseDelta/3~Delta 68 3~Deltaproductsdifferfrom3~Wyeproductinthattheyhaveonly4conductorsinsideofthe cord,thereisno“neutral”conductorinaDeltaconfiguration.Thus,3~Deltaproductsareonly capableofdelivering250Vpoweroutput. Glossary 3-PhaseWye/3~Wye 3~Wyeproductisa5cordconfigurationwiththree“hot”wires,one“neutral”wireandone “ground”wire.Theneutralconductorfoundin3~Wyecordsallowstheoutputof110Vand/or 220V;thisoptionallowscabinetpowerdistributionunitconfigurationforeithervoltageswhichis popularinDataCenterenvironmentsduetoequipmentdemands. 30AmpPowerInput Support 30-amppowerinputsupportprovideshard-wired10’cordandappropriateL5-30orL6-30plug type. AC-AlternatingCurrent AC(alternatingcurrent)referstowhentheflowofelectricchargeperiodicallyreverses direction.Anelectricchargewouldforinstancemoveforward,thenbackward,thenforward, thenbackward,overandoveragain. Amps AmperesorAmpsareastandardmeasurementofelectricalcurrentforhowmuchelectricityis movingthroughawireatasettime.Theampdrawiscalculatedbytheelectricalrequirements ofthedevicespluggedin,andisregulatedbyacircuitbreakerorfuse. ApparentPower ApparentPoweristheproductofroot-mean-square(rms)voltagemultipliedbyrmscurrentand themeasurementbywhichpowercompaniesbill. BranchCircuitProtection SentryPDUsaresafety-agencycertifiedtothenewUL60950-1standard(CSA/UL/TUV)&the NationalElectricalCode(NEC),whichrequirebranchcircuitprotectionforreceptacles. CircuitBreaker ProtectedOutlets Poweroutletprotectionprovidedbythermalcircuitbreaker. CrestFactor Crestfactoristheratiobetweentheinstantaneouspeakcurrentrequiredbytheloadandthe RMScurrent. Highcrestfactorcanleadtooverheatingofpowersupplycomponents. DataCenter InfrastructureEfficiency (DCiE) DCiEisthereciprocalcalculationofPUE. DC-DirectCurrent Indirectcurrent(DC),theflowofelectricchargeisonlyinonedirection.Thisisincontrastto ACoralternatingcurrent. FuseProtectedOutlets PowerOutletprotectionprovidedbyfuses. High-AmpIn-Rush Protection High-AmpIn-rushrelaysaccommodatetheextremelyhighpowerin-rushspikesfromtoday’s switchingpowersupplies. IEC InternationalElectrotechnicalCommissionhasasetofstandardreceptaclesandoutlets. PopularizedbecauseIECplugscanoutputeither125voltsor250voltsaccordingtothecord thatispluggedintothem.ConfigurationsmostcommonlyusedinDataCenterOperations includeC13toC14adnC19toC20. IntegratedTemp/ HumidityProbes Two(2)RJ-styleconnectorslocatedonthefacepanelofthePDUsenclosureprovidesupport fortwo(2)IntegratedTemperature&HumidityProbeswithten-foot(10’)cablestoproviderealtimemeasurementsinthedatacentercabinet. LDAP/LDAPS ThesentryfamilyofproductssupportsLightweightDirectoryAccessProtocol(LDAP)Version3 includingLDAPS(LDAPoverTSL/SSL).ThissupportenableauthenticationwithLDAPservers; useraccountsdonotneedtobeindividuallycreatedlocallyoneachSentrydevice. 1/PUE=(ITEquipmentPowerx100%)/TotalFacilityPower Thisallowsadministratorstopre-defineandconfigure(ineachSentryproduct,andintheLDAP server)asetofnecessaryLDAPgroups,andaccessrightsforeach.User’saccessrightscan thenbeassignedorrevokedsimplybymakingtheuseramemberofoneormorepre-defined SentryLDAPgroups.Useraccountcanbeadded,deleted,orchangedintheLDAPserver withoutanychangesonindividualSentryproducts. SentryLDAPsupporthasbeentestedinthefollowingenvironments: -MicrosoftActiveDirectory(MSAD) -NovelleDirectory(eDir) -OpenLDAP LEDDigitalDisplayInput EasyviewingdisplayonthefaceoftheenclosurethatreportstheTrueRMSPowerMonitoring CurrentMonitor oftheaggregateloadonthepowercircuit(inamps). TheInputCurrentDisplayallowsinstallationengineerstoverifythereal-timecurrentdrawon thepowercircuit. Thiseliminatestheguessworkofestimatingthecurrentdrawandpreventsthecostlymistake of:1)overestimatingandrequiringextrapowerdropsinstalledor2)underestimatingand overloadingacircuit-puttingtheentercabinetatriskifacircuitbreakeratthemaincabinet PDUtrips. LoadSense-Input CurrentMonitorPer Outlet Individualinputcurrentmonitoring(“LoadSense”)providesreal-timepowermeasurementof theloadinampsoneachpowerinlet,accessibleviafirmwareinterface. 69 Glossary MultipleConcurrent Users MultipleconcurrentusersallowsseveraluserstobeloggedintoaSentryatthesametime.In thisway,differentusers,withaccessrightstoonlytheirequipment,canreboottheirdevice(s) whentheyneedto,withoutwaitingforanotherusertologoutoftheSentryunit. NEBSCompliant MeetsNEBSLevelOneandLevelThreerequirementsforco-locationinaBellCore(Telcordia) centraloffice. NEMA NationalElectricalManufacturersAssociationsetofstandardplugsandreceptacles.NEMA nomenclatureaddressesthepartconfigurationbylockingability(ifapplicable),5for125V,6 for250Volt,dash(-),followedbytheamperagerating(20A,30A)andaPforplugorRfor receptacle. I.E.5-20Risa125Vtwistlockreceptaclefor20Amps. POPS-PerOutlet PowerSensing PerOutletPowerSensingPDUsprovideinformationperindividualoutletincludes:currentload (A),voltage(V),power(kW),apparentpower(VA),crestfactor,andpowerfactor.Usingour groupingtechnology,powerinformationisavailableperdevice,groupsofdevices(application), individualCabinetPDUorcabinet. Power(kW) Timerateofdoingwork,usuallyexpressedinhorsepowerorwatts. PowerFactor PowerFactoristheratioofRealPowertoApparentPower. APowerFactorof100%indicatesperfectpower,whilelowervaluesindicatethatthecircuitis wastingenergy. PUE-PowerUsage Effectiveness PUE=TotalFacilityPower/ITEquipmentPower RealPower RealPoweristheRMSvalueofWatts. RealPowerdividedbyApparentPowerisameasurementoftheefficiencyofpowerusageona circuit. RedundantPower ProvidingtwoindependentpowersourcesforcriticalequipmenttoensureUptime.Froma cabinetPDUthiscanbeaccomplishedbyadualcircuitcabinetpowerdistributionunitwith eachcordpluggedintoaseparatepowersource,orbypowering2PDUswithdifferentpower sources(separateUPS,aUPSandagenerator,etc.) SinglePhasePower-1 PhasePower Distributionofalternatingcurrentelectricpowerusingasysteminwhichallthevoltagesofthe supplyvaryinunison.Single-phasedistributionisusedwhenloadsaremostlylightingand heating,withfewlargeelectricmotors. Asingle-phasesupplyconnectedtoanalternatingcurrentelectricmotordoesnotproducea revolvingmagneticfield;single-phasemotorsneedadditionalcircuitsforstarting,andsuch motorsareuncommonabove10or20kWinrating. SNMPManagement TheSentryfamilyofproductssupportstheSimpleNetworkManagementProtocol(SNMP). ThisallowsnetworkmanagementsystemstouseSNMPrequeststoretrieveinformationand controlpowerfortheindividualoutlets.TheSentryincludesanSNMPv1agentsupporting standardMIBIandMIBIIobjects.AprivateenterpriseMIBextension(Sentry3MIB)isalso supportedtoprovideremotepowercontrol. TrueRMSInputCurrent Monitoring InputCurrentMonitoringinSentrypowerproductsisreportedasthecumulativeload(inamps) oneachpowercircuitsothatdatacentermanagerscanobtainthedatatheyneedtoplantheir powerrequirementsandtomonitorpowertotheirITequipment.InputCurrentisreportedin AmpsandcanbeviewedlocallyontheenclosureviaanLEDDigitalDisplayandremotely, whenapplicable,viathefirmwareinterface. Voltage VoltageisalsoreferredtoasElectricaltensionandmeasureinitsSIunit,thevolt.Voltageis thedifferenceofelectricalpotentialbetweentwopointsofanelectricalorelectroniccircuit. Volts Afixedvalueforacircuitthatisameasurementofelectricalpotential. Watts Measurementofelectricalpowerbeingutilizedbyasystem. ThesimplestcalculatedofaWattisoneAmpmultipliedbyelectricalpotentialofoneVolt. TrusRMScalculationstakenintoconsiderationthephasesofthevoltage,andshapeofthe currentwavestoacircuitinordertoprovidethepowerreading.DifferencebetweentheRMS wattvalueandthecalculationofVoltsmultipliedbyAmpsindicatesaninefficiencyinhow powerisdeliveredorconsumedbythecircuit. 70 IP54Rated Limitedingressofdustpermitted(noharmfuldeposit).Protectedagainstwatersplashedfrom alldirections.Limitedingresspermitted. IP65Rated Totallyprotectedagainsttheingressofdustandprotectedagainstjetsofwater.Limitedingress permitted. IP66Rated TotallyprotectedagainsttheingressofdustandProtectedagainststrongjetsofwater.Limited ingresspermitted. Glossary Topology - Figure 1 AWG Wire Sizes (see sample table) IntheAmericanWireGauge(AWG),diameterscanbecalculatedbyapplyingtheformulaD(AWG)=.005·92((36AWG)/39)inch.Forthe00,000,0000etc.gaugesyouuse-1,-2,-3,whichmakesmoresensemathematically than“doublenought.”ThismeansthatinAmericanwiregageevery6gaugedecreasegivesadoublingofthewire diameter,andevery3gaugedecreasedoublesthewirecrosssectionalarea.JustlikedBinsignallevels. Metric Wire Gauges IntheMetricGaugescale,thegaugeis10timesthediameterinmillimetres,soa50gaugemetricwirewould be5mmindiameter.NotethatinAWGthediametergoesupasthegaugegoesdownmetricistheopposite. Probablybecauseofthisconfusion,mostofthetimemetricsizedwireisspecifiedinmillimetresratherthanmetric gauges. AWG (American Wire Gauge) Sample Table AWG Gauge Diameter mm Ohms/km AWG Gauge Diameter mm Ohms/km 14 15 1.62814 8.282 23 0.57404 66.7808 1.45034 10.44352 24 0.51054 84.1976 16 1.29032 13.17248 25 0.45466 106.1736 17 1.15062 16.60992 26 0.40386 133.8568 18 1.02362 20.9428 27 0.36068 168.8216 19 0.91186 26.40728 28 0.32004 212.872 20 0.8128 33.292 29 0.28702 268.4024 21 0.7239 41.984 30 0.254 338.496 22 0.64516 52.9392 31 0.22606 426.728 71 Notes 72 Notes 73 DISTRIBUTED BY Head Office, Johannesburg 51-57 Gibbs Road Devland 1813 Johannesburg South Africa Tel (S-board): +27 (0) 11 983 7000 Fax : +27 (0) 11 938 9895 E-mail: info@adlerac.co.za www.adlerac.co.za 0861 ADLERAC (2353722)