Brochure

advertisement
Huawei IDS2000-M Medium
Modular Data Center Solution
With the development of network technology and communication technology, data center
has become the core of enterprise information construction. In order to meet requirements
of various business as well as the upcoming era of cloud computing, Huawei launched the
IDS2000-M medium modular data center solution via the in-depth understanding of the
traditional medium-scale data centers. It is designed as innovative concept of 'All-In-Room',
and features high density modularization, optimal reliability and security, fast deployment,
cost effectiveness, energy saving, and excellent monitoring.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei IDS2000-M medium modular data center solution can be widely used in the IDC of industry parks, branch offices of large
enterprise, SME, government networks, branches of education, medical, financial industrial, as well as small VDI data center and high
performance computing data center etc.
Single-Row with Aisle
Containment
PDF
Battery
AC
IT Cabinet
AC
Cableing
Cabinet
2-6 IT racks
7-11kW per rack
2-6 IT racks
0.6m
1.2m
0.6m
1.2m
AC
AC
1.5m
1.1m
Single-Row without
Aisle Containment
Cold Aisle Containment
1-7kW per rack
PDF
Battery
IT Cabinet
Cabling
Cabinet
AC
IT Cabinet
End Doors
Dual-Row with Aisle
Containment
4-16 IT racks
Cabling
Cabinet
IT Cabinet
AC
Cold Aisle Containment
7-11kW per rack
PDF
UPS
Battery
IT Cabinet
AC
Cabling
Cabinet
1.2m
4-16 IT racks
1-7kW per rack
Cabling
Cabinet
1.4m
Dual-Row without
Aisle Containment
1.2m
0.6m
AC
0.3m
AC
0.3m
1.2m
AC
1.2m
PDF
UPS
Battery
Cabling
Cabinet
Customer Value
As an All-In-Room solution, IDS2000-M medium modular data center features high density modularization, optimal reliability and security, fast
deployment, cost effectiveness, energy saving, and excellent monitoring.
High Density Modularization
Fast Deployment
• The small data center integrates cabinets, power supply &
• Single-row or dual-row, with or without aisle containment
distribution system, cooling system, monitoring system, cabling
could be chosen based on data center dimensions and power
consumption of each cabinet.
system, and fire control system etc.
• Single cabinet supports rated power of 7 kW or 11 kW, which
meets various customer requirements.
• The small data center meets enterprise requirements for
web application and internal services. IT cabinets are flexibly
configured with servers and storage and network equipment.
Simple and Low Consumption
• Integrated cabling cabinets can be configured in the small data
• The data center is optimized from a room in an office building.
center or a cable distribution compartment for flexible network
• The small data center is installed on a concrete floor rather than
configurations.
on a raised floor, which greatly simplifies the corresponding
Optimal Reliability and Security
engineering tasks.
• By using in-row air conditioners, which are close to heat
sources, the cooling efficiency is improved greatly.
• Tier II and Tier III configurations can be expanded to Tier III+
and Tier IV configurations.
• Modular UPSs work in N+1 redundancy mode with long time
battery backup to improve the reliability of the small data center.
Excellent Monitoring
• Various sensors monitor modules in the small data center constantly.
• The web-based monitoring system enables the modules to be
remotely managed.
• Each uninterruptible power supply (UPS) is configured with
a manual maintenance bypass circuit breaker to prevent
misoperations.
Technical Specification
Item
Cabinet
Power
Distribution
Frame
In-row AC
(T1 condition)
In-row AC
(T3 condition)
Specification
Item
Specification
Standards
IEC60297-1
Cooling capacity
30kW / 12.5kW
Dimensions (H x W x D)
2000mm×600mm×1100mm
Refrigent
R407C / R22
Installation space
42U
Power
380V/50Hz
Protection level
IP20
Rated Current
125A/250A/400A Optional
Voltage
3PH 380 V or 220 V
Frequency
50 Hz or 60 Hz
Protection level
IP20
Cooling capacity
30kW / 20kW
Refrigent
R410A
Power
380V/50Hz
Operating temperature
Indoor AC: 5-45°C
Outdoor AC: -30°C to +45°C
Cooling capacity
30kW
Refrigent
R407C
Power
380V/50Hz
Operating temperature
Indoor AC: 5-45°C
Outdoor AC: -30°C to +55°C
CRAC
Operating temperature
UPS
T1 condition: Indoor AC: 5-45°C
Outdoor AC: -30°C to +45°C
T3 condition: Indoor AC: 5-45°C
Outdoor AC: -30°C to +55°C
Type
20kVA rack-mounted UPS;
80/120kVA Modular UPS
Voltage
20kVA rack-mounted UPS:
3PH 380, 400, 415 V;
80kVA /120kVA Modular UPS:
3PH 380 V or 220 V
Frequency
50 Hz or 60 Hz
Power factor
≥0.8
Efficiency with full load
≥94%
Noise(1meter)
≤70dB
Protection level
IP20
Copyright © Huawei Technologies Co., Ltd. 2012. All rights reserved.
General Disclaimer
The information in this document may contain predictive statements including,
without limitation, statements regarding the future financial and operating results,
future product portfolio, new technology, etc. There are a number of factors
that could cause actual results and developments to differ materially from those
expressed or implied in the predictive statements. Therefore, such information
is provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
Version No.: M3-308130201-20120702-C-1.0
www.huawei.com
Download